electronic<br />

Coded Keypad CSM 100<br />

Connection / Operation - Programming<br />

Code locking module optionally with an operation code number of 2, 3 or 4 digits.<br />

The F code number (operation code number) is the secret code used in order to activate the contact with<br />

the switch (door opening contact).<br />

After entering the last digits, you have 5 seconds until the contact with the switch is activated. There is<br />

one contact for opening and one contact for closing (1x UM).<br />

The F code may be changed at any moment, while it is made up of 2, 3 or 4 (0-9) digits.<br />

The P code (programming code) is required in order to change the F code or the P code.<br />

Caution: It is advisable that you change the P code (factory setting) and keep the notes with the<br />

new code in a safe location.<br />

2<br />

1-<br />

220 V<br />

+<br />

LOCK<br />

0 8V<br />

VT 12<br />

Transformer<br />

12V~/1,4A<br />

P code modification<br />

1 4 7 2 5 8<br />

#<br />

0 4<br />

#<br />

1 2 3 4 5 6<br />

#<br />

1 4 7 2 5 8<br />

#<br />

0 3<br />

Operation code<br />

#<br />

1<br />

#<br />

2<br />

P-Code factory setting<br />

147258<br />

Entering of present code<br />

Code P 147258<br />

Operation code<br />

Entering of new code<br />

F code modification Factory setting Code P 1234<br />

3 4<br />

Entering of 6-digit code P<br />

Entering of new code F<br />

-5 seconds after connection to voltage, the device will be ready<br />

for operation<br />

-The pause between digits should not last more than 3 seconds<br />

-In case you have forgotten the P code, contact the client service<br />

department Tel.: 210 9718692<br />

<strong>Technical</strong> specification:<br />

Operating voltage 8-18 V AC/DC Operating current 1 mA/20mA<br />

Link contact max. 40V/ Operating temperature – 25 to +50°C<br />

14<br />

For instance …Entrance to a<br />

particular space should be protected<br />

by means of a secret code.<br />

Code F= 2549<br />

The programming code<br />

should be changed to<br />

Code P = 264893<br />

Code P modification<br />

147258<br />

#<br />

04<br />

#<br />

264893<br />

#<br />

Modification of code F<br />

264893<br />

#<br />

03<br />

#<br />

2549<br />

#<br />

14