electronic<br />
Installation Instructions<br />
BUS-SYSTEM<br />
Line network<br />
Two common weak current<br />
telecommunication lines may be used for<br />
the <strong>CTC</strong>-Duo Plus Bus system, such as<br />
J-Y (St) Y.<br />
The power lines have to be routed in<br />
accordance with the standing specifications.<br />
Heavy and weak current line need to be<br />
routed separately.<br />
A minimum distance of 10 cm has to be<br />
maintained from the heavy current lines.<br />
The power supply to the Bus- guidance<br />
board passes through the VT 12 network<br />
transformer.<br />
The VT 12 transformer has to be connected<br />
by means of a separate 10 A safety switch.<br />
The installation of electronic appliances<br />
should only be performed by a specialised<br />
electrician.<br />
Caution:<br />
When installation of the <strong>CTC</strong>-Duo-PLUS Bus<br />
system is effected on an existing line network<br />
(e.g. installation of door bells), it will have to<br />
ensured that the lines are free from any<br />
foreign voltage.<br />
Line resistance should not exceed 600 Ohm.<br />
The theoretic line length values resulting for<br />
a mean copper cable thickness of 0,6 mm<br />
exceed 4,5 km.<br />
A BTU Bus entry selector, a BSP 16<br />
central unit and a VT 12 network<br />
transformer will be required for each<br />
additional substation.<br />
Programming and operation<br />
Programming is basically taking place through the transposition of<br />
the jumpers at the HT 522 inphone.<br />
The BSP 16 Bus central unit offers the ability to change the<br />
duration of response of the door opening switch from 3 to 5<br />
seconds.<br />
(1) Set in operation in 5 seconds.<br />
The TLR 550M Bus loudspeaker module is installed within the<br />
keypad box (2).<br />
Bus line (3) is installed at terminals a+b.<br />
The entry substations are installed at the BR terminals (4)<br />
Accordingly to the needs, where the busy indication may be guided<br />
over the terminal (5) to the exterior (optional).<br />
The contacts of the door opening and additional function switches<br />
should not be connected to the 230V network voltage<br />
Maximum connection output 30 Watt or 60 VA at 12 V=/~.<br />
As an option, you may install the MDK 12-key keypad<br />
(connection 10).<br />
The only thing remaining is to program the HT 522 Bus<br />
inphones according to the binary code, through the<br />
installation of the jumpers.<br />
Following the call from the doorstation, the call receiver has<br />
approximately 30 seconds to lift the receiver, otherwise the call<br />
will have to be repeated.<br />
Communication is interrupted automatically after 45 seconds<br />
approximately.<br />
4<br />
4