<strong>ANSI</strong>/<strong>TIA</strong>-<strong>568</strong>-C.2: Balanced Twisted Pair<br />

Cabling Components<br />

This standard specifies electrical performance requirements for installed UTP cable and connecting hardware for each recognized category. Category 6A<br />

with extended frequency and additional parameters (ANEXT) is included. Performance categories, bandwidth, and field test parameters are listed in the<br />

table below.<br />

Table 1: Categories of Transmission Performance and Field Test Parameters<br />

Insertion Wire Delay Return<br />

Category Loss NEXT Length Map Skew ELFEXT Loss PSACR PSELFEXT PSNEXT ANEXT<br />

Cat 3 (16 MHz) 3 3 3 3<br />

Cat 5e (100 MHz) 3 3 3 3 3 3 3 3 3 3<br />

Cat 6 (250 MHz) 3 3 3 3 3 3 3 3 3 3<br />

Cat 6A (500 MHz) 3 3 3 3 3 3 3 3 3 3 3<br />

<strong>ANSI</strong>/<strong>TIA</strong>-<strong>568</strong>-C.2: Balanced Twisted Pair Cabling and Components<br />

The tables below incorporate enhanced performance requirements for UTP cables and connecting hardware: Category 3, 5e, 6, and 6A.<br />

Permanent Link Performance<br />

Insertion Loss<br />

Frequency Cat 5e Cat 6 Cat 6A<br />

(MHz) (dB) (dB) (dB)<br />

1.0 2.1 1.9 1.9<br />

4.0 3.9 3.5 3.5<br />

8.0 5.5 5.0 5.0<br />

10.0 6.2 5.5 5.5<br />

16.0 7.9 7.0 7.0<br />

20.0 8.9 7.9 7.8<br />

25.0 10.0 8.9 8.8<br />

31.25 11.2 10.0 9.8<br />

62.5 16.2 14.4 14.1<br />

100.0 21.0 18.6 18.0<br />

200.0 - 27.4 26.1<br />

250.0 - 31.1 29.5<br />

300.0 - - 32.7<br />

400.0 - - 38.5<br />

500.0 - - 43.8<br />

Channel Performance<br />

Insertion Loss<br />

Frequency Cat 5e Cat 6 Cat 6A<br />

(MHz) (dB) (dB) (dB)<br />

1.0 2.2 2.1 2.3<br />

4.0 4.5 4.0 4.2<br />

8.0 6.3 5.7 5.8<br />

10.0 7.1 6.3 6.5<br />

16.0 9.1 8.0 8.2<br />

20.0 10.2 9.0 9.2<br />

25.0 11.4 10.1 10.2<br />

31.25 12.9 11.4 11.5<br />

62.5 18.6 16.5 16.4<br />

100.0 24.0 21.3 20.9<br />

200.0 - 31.5 30.1<br />

250.0 - 35.9 33.9<br />

300.0 - - 37.4<br />

400.0 - - 43.7<br />

500.0 - - 49.3<br />

Patch Cord Performance<br />

Return Loss<br />

Frequency Cat 5e Cat 6 Cat 6A<br />

(MHz) (dB) (dB) (dB)<br />

1.0 25.0 25.0 20.0<br />

4.0 25.0 25.0 23.0<br />

8.0 25.0 25.0 24.5<br />

10.0 25.0 25.0 25.0<br />

16.0 25.0 25.0 25.0<br />

20.0 24.0 25.0 25.0<br />

31.25 23.1 23.1 23.3<br />

62.5 20.1 20.1 20.7<br />

100.0 18.0 18.0 19.0<br />

200.0 - 15.0 16.4<br />

250.0 - 14.0 15.6<br />

300.0 - - 14.9<br />

400.0 - - 13.8<br />

500.0 - - 13.0<br />

Return Loss<br />

Frequency Cat 5e Cat 6 Cat 6A<br />

(MHz) (dB) (dB) (dB)<br />

1.0 19.0 19.1 19.1<br />

4.0 19.0 21.0 21.0<br />

8.0 19.0 21.0 21.0<br />

10.0 19.0 21.0 21.0<br />

16.0 19.0 20.0 20.0<br />

20.0 19.0 19.5 19.5<br />

25.0 18.0 19.0 19.0<br />

31.25 17.1 18.5 18.5<br />

62.5 14.1 16.0 16.0<br />

100.0 12.0 14.0 14.0<br />

200.0 - 11.0 11.0<br />

250.0 - 10.0 10.0<br />

300.0 - - 9.2<br />

400.0 - - 8.0<br />

500.0 - - 8.0<br />

Return Loss<br />

Frequency Cat 5e Cat 6 Cat 6A<br />

(MHz) (dB) (dB) (dB)<br />

1.0 17.0 19.0 19.0<br />

4.0 17.0 19.0 19.0<br />

8.0 17.0 19.0 19.0<br />

10.0 17.0 19.0 19.0<br />

16.0 17.0 18.0 18.0<br />

20.0 17.0 17.5 17.5<br />

25.0 16.0 17.0 17.0<br />

31.25 15.1 16.5 16.5<br />

62.5 12.1 14.0 14.0<br />

100.0 10.0 12.0 12.0<br />

200.0 - 9.0 9.0<br />

250.0 - 8.0 8.0<br />

300.0 - - 7.2<br />

400.0 - - 6.0<br />

500.0 - - 6.0<br />

NEXT Loss - Category 6<br />

Frequency Cord Limit (dB)<br />

(MHz) 2m 5m 10m<br />

1.0 65.0 65.0 65.0<br />

4.0 65.0 65.0 65.0<br />

8.0 65.0 65.0 64.8<br />

10.0 65.0 64.5 62.9<br />

16.0 62.0 60.5 59.0<br />

20.0 60.1 58.6 57.2<br />

25.0 58.1 56.8 55.4<br />

31.25 56.2 54.9 53.6<br />

62.5 50.4 49.2 48.1<br />

100.0 46.4 45.3 44.4<br />

125 44.5 43.5 42.7<br />

150 43.0 42.1 41.4<br />

175 41.8 40.9 40.2<br />

200 40.6 39.8 39.3<br />

225 39.7 38.9 38.4<br />

250 38.8 38.1 37.6<br />

NEXT Loss<br />

Frequency Cat 5e Cat 6 Cat 6A<br />

(MHz) (dB) (dB) (dB)<br />

1.0 60.0 65.0 65.0<br />

4.0 54.8 64.1 64.1<br />

8.0 50.0 59.4 59.4<br />

10.0 48.5 57.8 57.8<br />

16.0 45.2 54.6 54.6<br />

20.0 43.7 53.1 53.1<br />

25.0 42.1 51.5 51.5<br />

31.25 40.5 50.0 50.0<br />

62.5 35.7 45.1 45.1<br />

100.0 32.3 41.8 41.8<br />

200.0 - 36.9 36.9<br />

250.0 - 35.3 35.3<br />

300.0 - - 34.0<br />

400.0 - - 29.9<br />

500.0 - - 26.7<br />

NEXT Loss<br />

Frequency Cat 5e Cat 6 Cat 6A<br />

(MHz) (dB) (dB) (dB)<br />

1.0 60.0 65.0 65.0<br />

4.0 53.5 63.0 63.0<br />

8.0 48.6 58.2 58.2<br />

10.0 47.0 56.6 56.6<br />

16.0 43.6 53.2 53.2<br />

20.0 42.0 51.6 51.6<br />

25.0 40.3 50.0 50.0<br />

31.25 38.7 48.4 48.4<br />

62.5 33.6 43.4 43.4<br />

100.0 30.1 39.9 39.9<br />

200.0 - 34.8 34.8<br />

250.0 - 33.1 33.1<br />

300.0 - - 31.7<br />

400.0 - - 28.7<br />

500.0 - - 26.1<br />

NEXT Loss - Category 6A<br />

Frequency Cord Limit (dB)<br />

(MHz) 1m 2m 5m 10m<br />

1.0 65.0 65.0 65.0 65.0<br />

4.0 65.0 65.0 65.0 65.0<br />

8.0 65.0 65.0 65.0 64.8<br />

10.0 65.0 65.0 64.5 62.9<br />

16.0 62.6 62.0 60.5 59.1<br />

20.0 60.7 60.1 58.6 57.2<br />

25.0 58.8 58.2 56.8 55.4<br />

31.25 56.9 56.3 54.9 53.6<br />

62.5 51.0 50.4 49.2 48.1<br />

100.0 47.0 46.4 45.4 44.5<br />

200 41.1 40.7 39.9 39.3<br />

250 39.3 38.9 38.1 37.7<br />

300 36.4 36.2 35.9 35.8<br />

400 31.8 31.9 32.1 32.5<br />

500 28.2 28.4 29.0 29.8<br />