Standard UTP <strong>Wiring</strong> Conventions<br />
Horizontal UTP Cable and Patch Cords<br />
• Solid copper 4-pair 24 AWG UTP is specified for distribution cabling. Stranded UTP<br />
is specified for patch cords for flexibility. Shielded cable is not commonly used in the<br />
U.S. Splices bridge taps are not permitted.<br />
• Cable, connectors and patch cords shall be marked with the performance category.<br />
Always match performance categories of cables and components throughout the<br />
infrastructure.<br />
• All cable, cords and connecting hardware shall meet performance requirements<br />
of <strong>ANSI</strong>/<strong>TIA</strong>-<strong>568</strong>-C.2. <strong>Hubbell</strong> assures this compliance with all products and<br />
cable partners.<br />
COLOR CODING:<br />
white-blue/blue<br />
white-orange/orange<br />
white-green/green<br />
white-brown/brown<br />
Backbone UTP Cable<br />
• Solid copper 4-pair and 25-pair UTP is specified. An overall shield is optional.<br />
• Performance category markings and compliance to <strong>ANSI</strong>/<strong>TIA</strong>-<strong>568</strong>-C.1 and <strong>568</strong>-C.2 is required.<br />
• Circuits with incompatible signals should be partitioned in separate binder groups. Prior to making shared sheath circuit<br />
assignments, consult the equipment manufacturer for signal characteristics (i.e., frequency, amplitude, voltage, etc.).<br />
• Tip conductor insulation colors are matched to the binder group. Ring conductor insulation colors correspond the pair.<br />
T e c h n i c a l I n f o r m a t i o n<br />
Recognized Connector and <strong>Wiring</strong> Configurations<br />
• 8-position modular jack/plug<br />
• 8-position modular panel/plug<br />
• T<strong>568</strong>A wiring or T<strong>568</strong>B wiring options<br />
• Cat 5e, Cat 6 or Cat 6A recommended<br />
RJ-45 <strong>ANSI</strong>/<strong>TIA</strong>-<strong>568</strong> <strong>Wiring</strong> Conventions<br />
Two wiring standards were adopted. Both configurations are based on maximum transmission performance.<br />
T<strong>568</strong>A<br />
1: Green/White<br />
2: Green<br />
3: Orange/White<br />
4: Blue<br />
5: Blue/White<br />
6: Orange<br />
7: Brown/White<br />
8: Brown<br />
• Preferred method<br />
• Directly compatible with<br />
2-pair voice and token<br />
ring systems utilizing<br />
6-position connectors<br />
T<strong>568</strong>B<br />
1: Orange/White<br />
2: Orange<br />
3: Green/White<br />
4: Blue<br />
5: Blue/White<br />
6: Green<br />
7: Brown/White<br />
8: Brown<br />
• Optional method<br />
• AT&T ® standard<br />
• Directly compatible with<br />
AT&T phone systems<br />
AT&T ® is a registered trademark of AT&T Inc.<br />