4. Activation of the updates<br />
a) Now reset the unit to factory defaults: (Setup → Misc →Load Factory → Yes).<br />
<strong>Installation</strong> of the four software updates replaces the entire application software of the <strong>ZE</strong>-<strong>NC2010</strong> and all<br />
your previous custom adjustments will be lost. You will have to redo them manually.<br />
b) We recommend to restore the AF function when in tuner mode.<br />
d) This update won’t touch the bluetooth and CAN-bus part of the firmware, which have to be installed<br />
separately if necessary.<br />
5 Version check<br />
After you applied all four software updates you need to perform a version check: (Setup > General > Page2 ><br />
Version..........). Only the version numbers of MCU, MPEG and APPS are of interest.<br />
The software status after succesfull updates should look like the following:<br />
APP_V 2.88.5_0311_100129<br />
MPG_V 2.1.88_0311_100126<br />
MCU_V 2.2.72_0311_100129<br />
The display of „ADP:….“ after the version number of the MCU signifies the software status of the CAN bus<br />
interface. If any deviation from the above mentioned status should occur, you can fix it by reapplying the<br />
respective part of the software. After doing so, reassure yourself by repeating the version check until you get<br />
the desired result.<br />
CAUTION :<br />
If one or even more of the partial updates fail, you may encounter strange erratic behaviour of your<br />
unit. Therefore version check and , in case of version check failure, reinstallation of the respective<br />
firmware parts are absolutely mandatory.<br />
Remark concerning password<br />
If you changed the default code of the theft protection please note that this also has been reset to<br />
factory defaults ( now you have to enter four times zero instead of your custom password).<br />
Unlock<br />
Depending on your previous software version, your device might lock itself after the MCU update<br />
process. Don´t panic, that´s not a big deal: Try „0000“ to unlock and if that´s not going to help push<br />
„SRC and“MUTE“ simultaneously until you get the onscreen message „ENTER SUPERCODE“.<br />
Now type „123456“. Done.<br />
3 von 3<br />
12.02.2010 JL / Uwe Morath, Product Development