12<br />

PART 9: ELECTRICAL CONNECTIONS<br />

This water heater is normally wired for 120 volts and shall be electrically grounded in accordance with<br />

local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70 (latest<br />

edition).<br />

This water heater must be connected to a grounded, metal, permanent wiring system, or an equipment<br />

grounding conductor must be run with the circuit conductors and connected to the equipment grounding<br />

terminal or lead on the water heater. If any of the original wiring must be replaced, replacement shall be<br />

with 105 degree C wire or equivalent.<br />

Figure 4 – Wiring Diagrams<br />

PART 10: WATER CONNECTIONS<br />

If sweat fittings are to be used, DO NOT apply heat to the nipples on top of the water heater. Sweat the<br />

tubing to the adapter before fitting the adapter to water connections.<br />

DO NOT apply heat to nipples containing a plastic insert. Heat traps may have been provided in the inlet<br />

and outlet nipples. DO NOT ATTEMPT to remove the plastic inserts.