c. Walkways shall be kept free from mud, ice, snow, grease, or any<br />

other materials, obstructions, or tripping hazards which would render<br />

them unsafe to the person using them. Access walkways shall have even,<br />

non-skid surfaces. Carpeting shall not be permitted.<br />

d. Walkways shall be above the water at all times and shall be<br />

adequately secured to other walkways or other appropriate floating<br />

structures.<br />

e. Access walkways from shore to dock should be constructed in such<br />

a manner as to allow persons with disabilities access.<br />

5. Handrails.<br />

a. Handrails shall be provided on all stairways and walkways.<br />

b. Handrails shall be 42 inches in height, with an intermediate<br />

rail approximately 22 inches in height.<br />

c. Handrails must be capable of withstanding loads of 200 pounds<br />

applied in any direction at any point with a minimum of deflection.<br />

They must be structurally sound, maintained at any point with a minimum<br />

of deflection and a minimum size of 2 inch by 4 inch, or equivalent<br />

strength material. Posts for handrails shall be spaced on no more than<br />

8 foot centers. Handrails shall be smooth-surfaced with no protruding<br />

uprights posts.<br />

6. Fire Protection.<br />

a. A fully charged A-B-C dry chemical fire extinguisher of not less<br />

than 10 pounds in capacity shall be located within a 50-foot radius of<br />

travel on every dock.<br />

b. All fire extinguishers must be inspected by the owner on a<br />

monthly basis to insure that they are fully charged and in operating<br />

condition.<br />

c. Immediate notification of the nearest fire department in the<br />

event of fires shall be an established operating procedure. Emergency<br />

numbers shall be posted on a conspicuous place near each fire<br />

extinguisher.<br />

d. Combustible waste material and residues shall be kept to a<br />

minimum, stored in covered metal receptacles, and disposed of daily.<br />