<strong>MULTIMIX</strong> 8/4 DIGITAL<br />

The voltage for phantom power on pin 6 is 12 Volt. By using the plug modules<br />

<strong>ITEC</strong>-MM-Ph-24 and <strong>ITEC</strong>-MM-Ph-48 respectively you can achieve higher phantom<br />

voltages.<br />

Attention: When using 48 Volt phantom voltage, short-circuiting the input signal wires on<br />

ground must be avoided.<br />

8) External control inputs:<br />

15-pole Sub-Min-D-socket on the housings rear panel, called ”EXT.CONTROL“.<br />

volume remote control:<br />

A simple volume remote control becomes possible by using the control inputs „External“.<br />

The 8 control inputs can be activated with external potentiometers and a control DC of<br />

0 -10V respectively. It is your choice (see software description) which input channels you<br />

decide to control.<br />

Configuration change:<br />

The same socket houses the control inputs for a configuration switch. External switch<br />

contacts activate one of the 15 predetermined settings.<br />

Socket allocation:<br />

8 a) External potentiometer:<br />

9<br />

1….External1 9 …External2<br />

2….External3 10…External4<br />

3….External5 11…External6<br />

4….External7 12…External8<br />

5.... +10 Volt 13…GND<br />

6....Config.1 14...Config.2<br />

7....Config.4 15...Config.8<br />

8....GND<br />

EXTERNAL POTENTIOMETERS<br />

Ext pot 1<br />

Ext pot 8<br />