DACA-EEDEN09-720 Daikin Altherma Engineering Data - Thermal ...
DACA-EEDEN09-720 Daikin Altherma Engineering Data - Thermal ...
DACA-EEDEN09-720 Daikin Altherma Engineering Data - Thermal ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>DACA</strong>-<strong>EEDEN09</strong>-<strong>720</strong><br />
Split System Component Selection<br />
6. Split System Component Selection<br />
<strong>Daikin</strong> <strong>Altherma</strong> Split System Component Selection (All Outdoor units have base pan heater)<br />
<strong>Daikin</strong> <strong>Altherma</strong><br />
System Selection<br />
from Checklist<br />
Size Selection of<br />
<strong>Daikin</strong> <strong>Altherma</strong><br />
Based on Heat Loss<br />
<strong>Daikin</strong> <strong>Altherma</strong><br />
Options from<br />
Checklist<br />
Heating<br />
Only<br />
and/or<br />
DHW<br />
Yes<br />
ERLQ036<br />
ERLQ048<br />
ERLQ054<br />
Outdoor<br />
Unit<br />
EKHBH054BA3<br />
EKHBH054BA6<br />
(3=3 kW; 6=6 kW Backup<br />
Heater)<br />
Indoor Unit<br />
No<br />
Size Selection of<br />
<strong>Daikin</strong> <strong>Altherma</strong><br />
Based on Heat Loss<br />
<strong>Daikin</strong> <strong>Altherma</strong><br />
Options from<br />
Checklist<br />
Heating,<br />
Cooling<br />
and/or<br />
DHW<br />
Yes<br />
ERLQ036<br />
ERLQ048<br />
ERLQ054<br />
Outdoor<br />
Unit<br />
EKHBX054BA3<br />
EKHBX054BA6<br />
(3=3 kW; 6=6 kW Backup<br />
Heater)<br />
Indoor Unit<br />
EKHBDP Condensate Kit<br />
(Must be applied to<br />
heating/cooling hydro box)<br />
EKHWS050BA3 (50 gal)<br />
EKHWS080BA3 (80 gal)<br />
Both DHW Tanks Have<br />
3 kW Booster Heater<br />
DHW Solar Option<br />
EKSOLHWBA<br />
EKRTWA<br />
Wired Room<br />
Thermostat<br />
EKRP1HBAAU<br />
Digital I/O PCB<br />
EKHWS050BA3 (50 gal)<br />
EKHWS080BA3 (80 gal)<br />
Both DHW Tanks Have<br />
3 kW Booster Heater<br />
DHW Solar Option<br />
EKSOLHWBA<br />
EKRTWA<br />
Wired Room<br />
Thermostat<br />
EKRP1HBAAU<br />
Digital I/O PCB<br />
14 Split System Component Selection