03.02.2015 Views

ADC active digital controller user manual

ADC active digital controller user manual

ADC active digital controller user manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Active Digital Controller<br />

2 TECHNICAL DATA<br />

2.1 Electrical data<br />

PAGE<br />

3<br />

Connector type CEE/IEC 320<br />

Electrical supply<br />

100 to 240 V a.c. 47 to 63 Hz<br />

Power consumption 15 W maximum<br />

Peak inrush current<br />

20 A at 110 V a.c.<br />

40 A at 240 V a.c.<br />

Fuse<br />

The unit is protected by an internal fuse.<br />

This fuse is not <strong>user</strong> replaceable.<br />

2.2 Operating and storage data<br />

Ambient operating temperature range<br />

Ambient storage temperature range<br />

Maximum ambient operating humidity<br />

Maximum operating altitude<br />

IP rating<br />

0 o C to 40 o C<br />

-30 o C to 70 o C<br />

Max 90% RH non condensing at 40 o C<br />

2000 m max<br />

IP20. IP40 when panel mounted. For indoor use only.<br />

TECHNICAL DATA<br />

2.3 Mechanical data<br />

Mass<br />

Dimensions (w x h x d)<br />

Panel cut-out<br />

Panel thickness<br />

0.33 kg<br />

96 x 48 x 165 mm<br />

92 +0.8 x 45 +0.6 mm to DIN43700<br />

1.5 mm minimum<br />

2.4 Display<br />

Type<br />

Update rate<br />

High brightness green LED 7-segment display<br />

LED enunciators for units and display mode<br />

300 ms<br />

Jun 06<br />

3<br />

Issue C