Active Digital Controller<br />
2 TECHNICAL DATA<br />
2.1 Electrical data<br />
PAGE<br />
3<br />
Connector type CEE/IEC 320<br />
Electrical supply<br />
100 to 240 V a.c. 47 to 63 Hz<br />
Power consumption 15 W maximum<br />
Peak inrush current<br />
20 A at 110 V a.c.<br />
40 A at 240 V a.c.<br />
Fuse<br />
The unit is protected by an internal fuse.<br />
This fuse is not <strong>user</strong> replaceable.<br />
2.2 Operating and storage data<br />
Ambient operating temperature range<br />
Ambient storage temperature range<br />
Maximum ambient operating humidity<br />
Maximum operating altitude<br />
IP rating<br />
0 o C to 40 o C<br />
-30 o C to 70 o C<br />
Max 90% RH non condensing at 40 o C<br />
2000 m max<br />
IP20. IP40 when panel mounted. For indoor use only.<br />
TECHNICAL DATA<br />
2.3 Mechanical data<br />
Mass<br />
Dimensions (w x h x d)<br />
Panel cut-out<br />
Panel thickness<br />
0.33 kg<br />
96 x 48 x 165 mm<br />
92 +0.8 x 45 +0.6 mm to DIN43700<br />
1.5 mm minimum<br />
2.4 Display<br />
Type<br />
Update rate<br />
High brightness green LED 7-segment display<br />
LED enunciators for units and display mode<br />
300 ms<br />
Jun 06<br />
3<br />
Issue C