You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Setting Battery Types on the Main Unit<br />
You can attach different types of lead-acid batteries to the <strong>Freedom</strong> <strong>HF</strong>.<br />
Before installing batteries make sure that you configure the unit to<br />
optimize the charging process.<br />
FIRE HAZARD<br />
Incorrectly setting the battery type can lead to battery damage and<br />
a risk of fire.<br />
Failure to follow these instructions can result in death or serious<br />
injury.<br />
The settings can be changed by adjusting the dip switches found on the<br />
main unit behind the display panel.<br />
Battery<br />
Type<br />
Dip Switch Setting<br />
Switch 1|Switch 2<br />
Bulk/Absorption<br />
Float<br />
Fixed OFF|OFF 13.5 13.5<br />
Flooded OFF|ON (default) 14.4 13.5<br />
GEL ON|OFF 14.2 13.8<br />
AGM ON|ON 14.3 13.4<br />
To adjust the battery type setting:<br />
By default the battery type is set to Flooded (OFF|ON).<br />
1. Detach the Display Panel to expose the Dip Switches.<br />
2. Use the tip of your fingernail or a small screw driver with a flat tip to<br />
adjust the switches.<br />
OFF<br />
ON<br />
Switch 1 | Switch 2<br />
Figure 3-1 Dip Switches (Default Settings Shown)<br />
3–2 975-0390-01-01