4. Continue pressing the Select button to cycle through the two settings<br />
– “AL0” and “AL1” until you reach the desired setting.<br />
5. Press and hold the Select button for five seconds to make the setting<br />
permanent.<br />
By default the<br />
low voltage<br />
setting is set to<br />
Low.<br />
To adjust the under voltage shutdown setting:<br />
Low (“sdL”) sets the under voltage shutdown threshold to 10.5 V.<br />
High (“SdH”) sets the under voltage shutdown threshold to 11.8 V.<br />
1. Press and hold the Power button for five seconds.<br />
2. Press the Power button three times.<br />
The LED screen will flash “Sd” intermittently.<br />
3. Press the Select button once.<br />
The LED screen will display the present (or most recent) low voltage<br />
setting.<br />
Example, “SdL” for a low shutdown voltage setting.<br />
4. Continue pressing the Select button to cycle through the two settings<br />
– “SdH” and “SdL” until you reach the desired setting.<br />
5. Press and hold the Select button for five seconds to make the setting<br />
permanent.<br />
To return all feature settings to factory default settings:<br />
1. Press and hold the Power button for five seconds.<br />
2. Press the Power button four times.<br />
The LED screen will flash “def” intermittently.<br />
3. Press and hold the Select button for five seconds to return all feature<br />
settings to their factory default settings.<br />