4. Continue pressing the Select button to cycle through the two settings<br />

– “AL0” and “AL1” until you reach the desired setting.<br />

5. Press and hold the Select button for five seconds to make the setting<br />

permanent.<br />

By default the<br />

low voltage<br />

setting is set to<br />

Low.<br />

To adjust the under voltage shutdown setting:<br />

Low (“sdL”) sets the under voltage shutdown threshold to 10.5 V.<br />

High (“SdH”) sets the under voltage shutdown threshold to 11.8 V.<br />

1. Press and hold the Power button for five seconds.<br />

2. Press the Power button three times.<br />

The LED screen will flash “Sd” intermittently.<br />

3. Press the Select button once.<br />

The LED screen will display the present (or most recent) low voltage<br />

setting.<br />

Example, “SdL” for a low shutdown voltage setting.<br />

4. Continue pressing the Select button to cycle through the two settings<br />

– “SdH” and “SdL” until you reach the desired setting.<br />

5. Press and hold the Select button for five seconds to make the setting<br />

permanent.<br />

To return all feature settings to factory default settings:<br />

1. Press and hold the Power button for five seconds.<br />

2. Press the Power button four times.<br />

The LED screen will flash “def” intermittently.<br />

3. Press and hold the Select button for five seconds to return all feature<br />

settings to their factory default settings.<br />