VENTILATION AND <strong>AIR</strong>-CONDITIONING-<strong>UNITS</strong><br />

<strong>AIR</strong>-<strong>HANDLING</strong>-<strong>UNITS</strong> <strong>AT6</strong> –<br />

<strong>FOR</strong> <strong>BIG</strong> <strong>AIR</strong>-<strong>VOLUMES</strong>


2<br />

<strong>AT6</strong> – for big air-volumes


Advantages that convince<br />

I variable and optimized customization<br />

for all specifi c applications<br />

I high product quality using state-ofthe-art<br />

manufacturing technology<br />

I customer-orientated process control<br />

guarantees maximum delivery reliability<br />

I planning and evaluation using Klim@<br />

Soft ® , the professional design program<br />

for planners and architects<br />

I unit design in accordance with VDI<br />

6022<br />

Design with excellent construction<br />

characteristics<br />

I maximum corrosion protection using<br />

galvanized housing panels and powdercoated<br />

I high thermal and noise insulation<br />

using 58 mm panel thickness<br />

I noise and thermal insulation made<br />

from rock wool; building material class<br />

A1; non-combustible in accordance<br />

with DIN 4102<br />

I patented thermal decoupling between<br />

the inner and outer shell<br />

I minimized thermal bridge using optimized<br />

housing capping<br />

I unit designed for disassembly<br />

I optimum adaptation to structural<br />

conditions using a variable module<br />

dimension of 102 mm<br />

3


4<br />

<strong>AT6</strong> – large units<br />

Inner walls hygienically smooth<br />

Patented thermal decoupling


Effi ciency and economy<br />

I reduced energy consumption through<br />

optimized incident air-fl ow to the function<br />

units and therefore minimizing the<br />

internal pressure posses<br />

I version of fan adapted to the location<br />

of operation<br />

I application of all established heat recovery<br />

systems; adapted to the respective<br />

application zone<br />

I “Life-Cycle-Costs” optimized units<br />

CON<strong>FOR</strong>MITY<br />

Conforms to all national and European standards<br />

Top quality for all application zones<br />

I inside and outside installation<br />

I hygienic construction<br />

I integrated cooling<br />

I various types of material<br />

5


6<br />

<strong>AT6</strong> – quick selection<br />

Air-Volume Size of unit External dimensions Internal dimensions<br />

m Width (mm) *Height (mm) Width (mm) *Height (mm)<br />

3 /h<br />

12 700 - 29 600 15 x 15 1 632 1 632 1 532 1 532<br />

15 200 - 35 500 18 x 15 1 938 1 632 1 838 1 532<br />

20 300 - 47 300 24 x 15 2 550 1 632 2 450 1 532<br />

26 200 - 61 100 31 x 15 3 264 1 632 3 164 1 532<br />

18 200 - 42 600 18 x 18 1 938 1 938 1 838 1 838<br />

21 300 - 49 700 21 x 18 2 244 1 938 2 144 1 838<br />

24 300 - 56 700 24 x 18 2 550 1 938 2 450 1 838<br />

31 400 - 73 300 31 x 18 3 264 1 938 3 164 1 838<br />

37 500 - 87 400 37 x 18 3 876 1 938 3 776 1 838<br />

24 800 - 57 900 21 x 21 2 244 2 244 2 144 2 144<br />

28 400 - 66 200 24 x 21 2 550 2 244 2 450 2 144<br />

31 900 - 74 500 27 x 21 2 856 2 244 2 756 2 144<br />

36 600 - 85 500 31 x 21 3 264 2 244 3 164 2 144<br />

40 200 - 93 700 34 x 21 3 570 2 244 3 470 2 144<br />

43 700 - 102 000 37 x 21 3 876 2 244 3 776 2 144<br />

47 300 - 110 300 40 x 21 4 182 2 244 4 082 2 144<br />

50 800 - 118 500 43 x 21 4 488 2 244 4 388 2 144<br />

32 400 - 75 600 24 x 24 2 550 2 550 2 450 2 450<br />

36 500 - 85 100 27 x 24 2 856 2 550 2 756 2 450<br />

41 900 - 97 700 31 x 24 3 264 2 550 3 164 2 450<br />

45 900 - 107 100 34 x 24 3 570 2 550 3 470 2 450<br />

50 000 - 116 600 37 x 24 3 876 2 550 3 776 2 450<br />

54 000 - 126 000 40 x 24 4 182 2 550 4 082 2 450<br />

58 100 - 135 500 43 x 24 4 488 2 550 4 388 2 450<br />

62 100 - 144 900 46 x 24 4 794 2 550 4 694 2 450<br />

66 200 - 154 400 49 x 24 5 100 2 550 5 000 2 450<br />

41 000 - 95 700 27 x 27 2 856 2 856 2 756 2 756<br />

47 100 - 109 900 31 x 27 3 264 2 856 3 164 2 756<br />

51 600 - 120 500 34 x 27 3 570 2 856 3 470 2 756<br />

56 200 - 131 100 37 x 27 3 876 2 856 3 776 2 756<br />

60 700 - 141 700 40 x 27 4 182 2 856 4 082 2 756<br />

65 300 - 152 400 43 x 27 4 488 2 856 4 388 2 756<br />

69 900 - 163 000 46 x 27 4 794 2 856 4 694 2 756<br />

74 400 - 173 600 49 x 27 5 100 2 856 5 000 2 756<br />

79 000 - 184 300 52 x 27 5 406 2 856 5 306 2 756<br />

83 500 - 194 900 55 x 27 5 712 2 856 5 612 2 756<br />

Subject to dimension and design changes. Further sizes of unit available on request.<br />

* Height without installation frame.<br />

Installation frame up to a width of 3 876 = 150 mm<br />

Installation frame up to a width of 4 488 = 200 mm<br />

Installation frame up to a width of 5 712 = 300 mm


<strong>AT6</strong> large units – abstract from the reference list<br />

Automobile industry<br />

I SVW | Kaluga (Russia)<br />

I Nissan | St. Petersburg (Russia)<br />

I Honda | Swindon (England)<br />

I Ford | Erlangen<br />

I Daimler R & D-dept. | Ulm<br />

I VW Halle 28 | Hannover<br />

I BMW | Dingolfi ng, Leipzig, München,<br />

Regensburg, South Africa<br />

I Daimler Chrysler | Wörth, Bremen,<br />

Stuttgart, Rastatt, Untertürkheim,<br />

Ulm, Sindelfi ngen<br />

I VW | Wolfsburg, Hannover, Bremen,<br />

Mexico<br />

I Opel | Rüsselsheim, Eisenach,<br />

Portugal<br />

I Audi | Ingolstadt<br />

I Peugeot | Mulhouse, Poissy, Nigeria,<br />

München, Madrid, Vigo (Spain), Trnava<br />

(Slovakia)<br />

I Renault | Bursa (Turkey), Dacia<br />

(Rumania), Valladolid (Spain)<br />

I Honda | Swindon (UK)<br />

Exhibition halls<br />

I Düsseldorf trade fair<br />

I Exhibition hall 2, Essen<br />

I Exhibition hall 3 and 9, Frankfurt<br />

I Exhibition hall 3, Essen<br />

I Trade fair / Expo 2000, Hannover<br />

I Trade fair Friedrichshafen<br />

I Exhibition centre Berlin<br />

Pharmaceutical / Chemical<br />

I Höchst | Frankfurt<br />

I Bayer AG | Leverkusen<br />

I Boehringer Ingelheim | Pharmaceutical<br />

Zaire works (Africa)<br />

I Biochemie | Frankfurt<br />

I Arche | Brazil<br />

General<br />

I Toho Tenax | Heinsberg<br />

I St. Johannis Hospital | Landstuhl<br />

I SAP | Walldorf<br />

I Ato Tech | Trebur<br />

I Wikus Hall 7<br />

I Famila | Oldenburg<br />

I ZF-gearbox dispatch building |<br />

Saarbrücken<br />

I CLID SAS | France, Turkey<br />

I Sachsenbatterie | Zwickau<br />

7


<strong>AL</strong>-<strong>KO</strong> THERM GmbH<br />

Hauptstraße 248-250<br />

89343 Jettingen-Scheppach<br />

Phone (+49) 82 25 / 39 - 269<br />

Fax (+49) 82 25 / 39 - 271<br />

E-Mail madelene.laeth@al-ko.de<br />

www.al-ko.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!