Deflection in case of incomplete interactioncomparison<br />

with test results<br />

G. Hanswille<br />

Univ.-Prof. Dr.-Ing.<br />

Institute for Steel and<br />

Composite Structures<br />

University of Wuppertal-Germany<br />

1875 1875<br />

F<br />

load case 1<br />

load case 2<br />

F<br />

F/2 F/2<br />

200<br />

F [kN]<br />

Deflection at<br />

midspan<br />

1875 3750<br />

1875<br />

7500<br />

150<br />

load case 2<br />

1500<br />

50<br />

100<br />

IPE 270<br />

270 175<br />

445<br />

50<br />

0<br />

load case 1<br />

20 40 60<br />

δ<br />

[mm]<br />

52