Mounting, installation<br />

5.2 Alignment and fastening<br />

5.1.4 Noise emission<br />

NOTICE<br />

When the noise that is emitted at workplaces of the personnel responsible for operating the<br />

equipment is assessed, it must be borne in mind that the A-weighted sound pressure level,<br />

measured in accordance with ISO 1680, namely 70 dB(A), is not exceeded if the threephase<br />

machines are operated with the rated output.<br />

5.2 Alignment and fastening<br />

5.2.1 General measures<br />

Make sure that the machine is level and ensure secure fastening of feet and flanges, precise<br />

alignment in the case of direct coupling, and also cleanliness of the fastening surfaces. Avoid<br />

installation-related resonances with the rotating frequency and double line frequency. Turn<br />

rotor by hand and pay attention to any unusual noises. Check the direction of rotation with<br />

the motor uncoupled.<br />

NOTICE<br />

Any paint damage that occurs when the machine is being aligned and fastened is to be<br />

immediately repaired in a technically appropriate manner.<br />

Measures<br />

The following measures are required in order to compensate any radial offset at the coupling<br />

and to horizontally adjust the electrical machine with respect to the driven load:<br />

● Vertical positioning<br />

Place shims under the machine feet to position it vertically and to prevent<br />

stress/distortion. The number of shims should be kept as low as possible, i.e. stack as<br />

few as possible.<br />

● Horizontal positioning<br />

To position the machine horizontally, push it sideways on the foundations and ensure that<br />

the axial position is maintained (angularity error).<br />

● When positioning the motor, ensure that there is a uniform axial gap around the coupling.<br />

● Smooth running<br />

Stable, vibration-free design of the foundations in accordance with DIN 4024 and precise<br />

alignment of the coupling, as well as a well-balanced transmission element (coupling, belt<br />

pulleys, fans, etc.), are prerequisites for smooth running with low vibration.<br />

● Complete balancing of the machine with the transmission element may be necessary.<br />

For details and evaluation criteria, see ISO 10816.<br />

1LA5/6/7/9, 1LP7/9, 1PP6/7/9, 1MA6/7, 1MF6/7, 1MJ6, 1LE1<br />

32 Operating Instructions, 10/2008, 5 610 00000 02 000