11.03.2015 Views

Industrial Product Guide - Nabic

Industrial Product Guide - Nabic

Industrial Product Guide - Nabic

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

LUBRICATED PLUG VALVES<br />

Cast Iron HNH-Milliken Plug Valves Operating and Test Pressures<br />

Flanged Sizes Pressure/Temperature Rating<br />

Hot<br />

Cold<br />

BS EN 1092-2 PN16 All 11.2 bar at 250°C 16 bar from -10 to 120°C<br />

ANSI B16.1 Class 125 1 /2 to 12" 125lbf/in 2 at 450°F 200lbf/in 2 from -20 to 150°F<br />

ANSI B16.1 Class 125 14 to 24" 100lbf/in 2 at 353°F 150lbf/in 2 from -20 to 150°F<br />

BS1560 Class 125 15 to 300mm 8.6 bar at 230°C 13.8 bar from -10 to 65°C<br />

BS1560 Class 125 350 to 600mm 6.9 bar at 180°C 10.3 bar from -10 to 65°C<br />

ANSI B16.1 Class 250 1 /2 to 12" 250Ibf/in 2 at 450°F 500lbf/in 2 from -20 to 150°F<br />

ANSI B16.1 Class 250 14 to 24" 200lbf/in 2 at 406°F 300lbf/in 2 from -20 to 150°F<br />

BS1560 Class 250 15 to 300mm 17.2 bar at 230°C 34.5 bar from -10 to 65°C<br />

BS1560 Class 250 350 to 600mm 14.1 bar at 200°C 20.7 bar from -10 to 65°C<br />

Screwed Sizes Pressure/Temperature Rating<br />

Hot<br />

Cold<br />

PN16 All 10.8 bar at 260°C 16 bar from -10 to 120°C<br />

(157lbf/in 2 at 500°F)<br />

(232lbf/in 2 from -23 to 248°F)<br />

Class 250 All 17.5 bar at 260°C 34.5 bar from -10 to 120°C<br />

(253lbf/in 2 at 500°F)<br />

(500lbf/in 2 from -23 to 248°F)<br />

Hydrostatic Test Pressures<br />

Fig. No End Pressure Nominal Body Test Seat Test<br />

Connection Rating Size bar lbf/in 2 bar lbf/in 2<br />

200M<br />

}<br />

DN15 ( 1 /2") to DN80 (3")<br />

200R Screwed PN16 DN25 (1") to DN50 (2") 24.0 348 17.6 255<br />

200L/T DN15 ( 1 /2") to DN50 (2")<br />

171MG Flanged PN16 DN150 (6") to DN600 (24")<br />

201M Flanged PN16 DN25 (1") to DN200 (8") 24.0 348 17.6 255<br />

201R<br />

}<br />

Flanged ANSI 125 DN32 (1 1 /4") to DN100 (4") 24.1 350 13.8 200<br />

201T Flanged ANSI 125 DN50 (2") to DN150 (6") 18.3 265 12.1 175<br />

221T DN80 (3")<br />

205M<br />

401M Flanged ANSI 250 DN50 (2”) to DN150 (6”) 51.7 750 34.5 500<br />

Note 1: All valves 1 /2" to 1 1 /2" inclusive<br />

are pneumatically tested to:<br />

Body: 6 to 7 bar<br />

Seat: 6 to 7 bar<br />

VALVE PRESSURE/<br />

TEMPERATURE RATING<br />

The pressure/temperature ratings given apply<br />

to the valve only.<br />

The maximum temperature at which a valve<br />

may operate depends upon the sealing<br />

compound with which the valve is filled.<br />

However, should the sealing compound have<br />

an operating temperature different to that of<br />

the valve the lower temperature must apply.<br />

Every effort has been made to ensure that the information contained in this publication is accurate at the time of publishing. Hattersley Ltd assumes no responsibility<br />

or liability for typographical errors or omissions or for any misinterpretation of the information within the publication and reserves the right to change without notice.<br />

26<br />

Technical Helpline: 0845 604 1790<br />

E: tech-enquiries@hattersley.com W: www.hattersley.com