COMPACT Test Switches<br />
Test Ear<br />
Allows testing from front of<br />
switchboard by use of clips and<br />
test plugs. Designed to positively<br />
prevent clips coming off unless<br />
spring tension is released.<br />
Stud<br />
Screw type terminal for back<br />
connection with screw and cup<br />
washer furnished for each stud<br />
connection. In front connected<br />
applications, terminal connections<br />
are made with screw stud and hex<br />
nut. These parts are furnished with<br />
each switch.<br />
Case and Cover<br />
Semi-Flush case is insulated for<br />
use with steel panel switchboards<br />
and is fastened by means of four<br />
screws furnished with the case. The<br />
screws are hidden by the cover<br />
and walls. Lucite cover is held in<br />
place with knurled cover stud nuts.<br />
Cover studs have wire sealing<br />
holes. Covers for front connected<br />
switches are optional and are<br />
made of Lucite.<br />
Barrier<br />
Phenolic barriers are provided<br />
between all poles.<br />
Meter Devices can supply test<br />
switches to meet practically any<br />
meter or relay testing requirement.<br />
Those standard switches are listed on<br />
pages 18 and 20. But if you need a<br />
special test switch you may design<br />
one to meet you own special use by<br />
application of the information<br />
outlined below. These assembly<br />
numbers are not the catalog numbers<br />
but are for convenience of switch<br />
layout.<br />
Standard Compact Switch Assemblies –<br />
for ordering test switches not cataloged<br />
For those desiring to<br />
use an oversize case<br />
with the test switch<br />
Assembly #1c<br />
Single pole potential<br />
Assembly #4c<br />
Solid thru bar<br />
Assembly #12c<br />
Single pole current<br />
element - right<br />
Assembly #13c<br />
Single pole current<br />
element - left<br />
Assembly #14c<br />
Double pole<br />
current element<br />
Assembly #15c<br />
Spacing Base<br />
Supplied between<br />
all poles<br />
Assembly #16c<br />
Double pole potential<br />
Assembly #17c<br />
Three pole potential<br />
Assembly #19c<br />
Barrier<br />
Assembly #26c<br />
Load test jack double<br />
pole current element<br />
right hand<br />
Assembly #27c<br />
Load test jack double<br />
pole current element<br />
left hand<br />
Assembly #28c<br />
Load test jack<br />
Single pole potential<br />
current element<br />
17