14.03.2015 Views

Sell Sheet - Patriot Supply

Sell Sheet - Patriot Supply

Sell Sheet - Patriot Supply

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Application:<br />

Gas-Fired Non-Integrated<br />

Forced-Air Furnaces<br />

and Boilers<br />

UNIVERSAL REPLACEMENT<br />

Carbide<br />

Non-Integrated<br />

Hot Surface Ignition Module<br />

Why Carry More… When Less Works Best!<br />

Quality Universal Replacement products to protect your reputation.<br />

White-Rodgers, a leader in furnace ignition technology, was the first manufacturer<br />

to incorporate a microcomputer-controlled primary safety control circuit to power a silicon<br />

carbide ignitor while using flame rectification.<br />

Now comes the 50E47-843 Universal Replacement for silicon carbide, non-integrated HSI<br />

modules. The 50E47-843 Universal replaces ALL White-Rodgers 50E47-xxx modules and virtually<br />

all competitive silicon carbide, non-integrated modules.<br />

The 50E47-843 Universal Kit has everything needed for a fast and accurate replacement, including<br />

a complete module cross-reference and program keys to quickly customize the module to the furnace<br />

application. Now you can carry one Universal Kit… and carry the best!<br />

Kit Includes<br />

•Program Keys<br />

•Mounting Hardware<br />

• Double-Sided Foam Back Tape<br />

(for ease of installation)<br />

• Extensive Cross-Reference Guide<br />

• Color-Coded Timing Label<br />

•Pre-Printed Hanging Carton<br />

Specifications<br />

Dimensions<br />

4.13"W x 4.13"H x 1.5"D<br />

Electrical Rating<br />

Input 18 to 30 VAC, 25 VAC nominal<br />

Max. Input Current<br />

@ 25 VAC; .250mA @ 25 C°<br />

Relay Load Settings<br />

Valve Relay: 1.5amps @ 28 VAC<br />

50/60 Hz .6pf<br />

Ignitor Relay: 1.52 115 VAC<br />

50/60 Hz resistive<br />

Features<br />

•Program Keys<br />

•Tri-Color LED Indicator<br />

for Diagnostics<br />

• Direct and Indirect<br />

Flame Sense<br />

50E47-843


Application:<br />

Gas-Fired Non-Integrated<br />

Forced-Air Furnaces<br />

and Boilers<br />

UNIVERSAL REPLACEMENT<br />

Carbide<br />

Non-Integrated<br />

Hot Surface Ignition Module<br />

M<br />

V<br />

2<br />

T<br />

R<br />

G<br />

N<br />

D<br />

Typical System Wiring Diagram<br />

with the 50E47 Module<br />

T<br />

H<br />

M<br />

V<br />

1<br />

L<br />

2<br />

H<br />

S<br />

2<br />

F<br />

P<br />

L<br />

1<br />

H<br />

S<br />

I<br />

Program Key Information<br />

Six Program Keys are provided for different applications. Refer<br />

to the enclosed installation instructions for detailed Program Key<br />

selections. This table shows Timings and Retries for each key.<br />

After selecting and inserting the proper key remove or dispose<br />

of the remaining keys.<br />

GAS VALVE<br />

MV<br />

MV<br />

BURNER<br />

GROUND<br />

THERMOSTAT or<br />

CONTROLLER<br />

FLAME<br />

PROBE<br />

ALTERNATE<br />

LIMIT<br />

BLUE<br />

RED<br />

ADAPTER<br />

LIMIT<br />

CONTROLLER<br />

TRANSFORMER<br />

L1<br />

(HOT)<br />

L2<br />

HOT<br />

SURFACE<br />

IGNITER<br />

PROGRAM KEY TIMING SPECIFICATIONS QUICK REFERENCE<br />

Key Trial For Ignition Retries Prepurge Warm-up<br />

A-Blue 4 sec. 0 30 sec. 45 sec.<br />

B-Red 4 sec. 2 30 sec. 45 sec.<br />

C-Green 7 sec. 0 30 sec. 45 sec.<br />

D-Violet 7 sec. 2 30 sec. 45 sec.<br />

E-Orange 4 sec. 2 30 sec. 17 sec.<br />

F-Yellow 7 sec. 2 30 sec. 17 sec.<br />

The 50E47-843 Universal Module Replaces the Following Carbide Non-Integrated Modules:<br />

White-Rodgers<br />

50E47/50F47-1 THRU 79<br />

50E47/50F47-101 THRU 179<br />

50E47/50F47-201 THRU 279<br />

50E47/50F47-301 THRU 379<br />

Robertshaw<br />

HS780-17NL-104A<br />

HS780-17NL-106A<br />

HS780-17NL-108A<br />

HS780-17NL-304A<br />

HS780-17NL-306A<br />

HS780-17NL-308A<br />

Installation Note:<br />

When installing, see the installation<br />

instructions for a complete timing<br />

specifications cross-reference guide.<br />

HS780-17NR-104A<br />

HS780-17NR-106A<br />

HS780-17NR-108A<br />

HS780-17NR-304A<br />

HS780-17NR-306A<br />

HS780-17NR-308A<br />

HS780-17NR-312A<br />

HS780-17PL-106A<br />

HS780-17PL-108A<br />

HS780-17PL-304A<br />

HS780-17PL-306A<br />

HS780-17PL-308A<br />

HS780-17PR-104A<br />

HS780-17PR-108A<br />

HS780-17PR-306A<br />

HS780-34NL-106A<br />

HS780-34NL-108A<br />

HS780-34NL-304A<br />

HS780-34NL-306A<br />

HS780-34NL-308A<br />

HS780-34NL-312A<br />

Honeywell<br />

S89C 1004<br />

S89C 1012<br />

S89C 1046<br />

S89C 1087<br />

S89C 1103<br />

HS780-34NR-104A<br />

HS780-34NR-106A<br />

HS780-34NR-304A<br />

HS780-34NR-306A<br />

HS780-34NR-308A<br />

HS780-34NR-312A<br />

S89D 1002<br />

S89G 1005<br />

S89G 1013<br />

S89G 1021<br />

S89G 1047<br />

S89H 1003<br />

S89H 1011<br />

S89H 1029<br />

S89J 1008<br />

HS780-34PL-104A<br />

HS780-34PL-106A<br />

HS780-34PL-108A<br />

HS780-34PL-304A<br />

HS780-34PL-306A<br />

HS780-34PL-308A<br />

S890C 1007<br />

S890D 1006<br />

S890G 1003<br />

S890G 1011<br />

S890G 1029<br />

HS780-34PR-106A<br />

HS780-34PR-108A<br />

HS780-34PR-304A<br />

HS780-34PR-306A<br />

HS780-34PR-308A<br />

S890G 1037<br />

S890H 1002<br />

S890H 1010<br />

S890H 1028<br />

Other Universal Controls From White-Rodgers<br />

Integrated Silicon Carbide Ignition Module<br />

50A55-843<br />

Replaces up to 30 Controls<br />

Integrated Nitride Ignition Module<br />

50A65-843<br />

Replaces up to 5 Controls<br />

Gas Valve<br />

36C68-423<br />

Fast Open/High Capacity<br />

Gas Valve<br />

36E36-304<br />

Fast Open/Standard Capacity<br />

Gas Valve<br />

36E98-304<br />

Slow Open/Standard Capacity<br />

WR-8449<br />

Controlling Indoor Comfort Worldwide<br />

Since 1937<br />

St. Louis, Missouri Markham, Ontario<br />

314-577-1300<br />

905-201-4701<br />

www.white-rodgers.com<br />

The Emerson logo is a trademark and<br />

a service mark of Emerson Electric Co.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!