Tool B-7:<br />

MVA 201 Sample Learning Assessment Tool (test & answer key)<br />

(Note that the CD-ROM contains a version for participants, that does not indicate correct answers)<br />

INSTRUCTIONS: Select the appropriate learning assessment and make one copy for each participant and<br />

administer at end of course to all participants. Review answers <strong>with</strong> all participants after they have completed test.<br />

This test is appropriate for all four course versions (<strong>with</strong> answer on #10 different for Multiple Use versus Re-Use)<br />

Learning Assessment: MVA 201 (Pelvic Model Practice <strong>with</strong> MVA)<br />

Name: ____________________________________ Date: ______________________<br />

1. The steps of processing include which of the following?<br />

a) Decontamination soak<br />

b) Cleaning<br />

c) High-level disinfection (HLD) or sterilization<br />

d) Storage<br />

e) All of the above [correct]<br />

2. Following an MVA procedure, all instruments that will be reused should be<br />

a) Kept wet until they can be cleaned [correct]<br />

b) Kept dry until they can be cleaned<br />

c) Kept in an air-tight storage device<br />

d) Immediately sterilized<br />

3. Which of the following methods is NOT acceptable for processing Ipas MVA Plus® aspirators?<br />

b) Sterrad Processor<br />

c) HLD <strong>with</strong> chemicals<br />

d) Dry heat [correct]<br />

e) Steam Sterilization<br />

4. Active Stock of MVA is<br />

a. New devices, in original packaging, in the facility store room<br />

b. The devices kept in the procedure room to serve women needing MVA in any given day or shift<br />

[correct]<br />

c. The devices in the central warehouse to send to facilities when requisitioned<br />

d. The devices the chief health practicioner keeps at her private practice to serve her patients<br />

5. The primary goal of forecasting MVA needs for health-care facilities is:<br />

a) To reduce the length of time between ordering and receiving new MVA aspirators<br />

b) To reduce the number of women whose health and lives are at risk when providers lack MVA<br />

when needed [correct]<br />

c) To increase the number of providers trained and equipped to offer care <strong>with</strong> MVA<br />

d) To help provide program information for potential donors<br />

6. When a clinic storeroom reaches the reorder point quantity for MVA devices, how many should be<br />

reordered?<br />

a. The Total Initial Stock<br />

b. The Reserve Maximum minus the reorder point quantity [correct]<br />

c. The Active Stock plus the Reserve Stock quantities<br />

d. The Reserve Maximum<br />

UTERINE EVACUATION WITH MVA: A TRAINING MANUAL FOR CONDUCTING SHORT COURSES Page 18