16.03.2015 Views

0 NEW Product Guide LEAFLETS - Mitsubishi Heavy Industries Ltd.

0 NEW Product Guide LEAFLETS - Mitsubishi Heavy Industries Ltd.

0 NEW Product Guide LEAFLETS - Mitsubishi Heavy Industries Ltd.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Mitsubishi</strong> <strong>Heavy</strong> <strong>Industries</strong> has made a giant leap forward in air<br />

conditioning and heat pump technology, with the development of high<br />

performance FD Series split systems for commercial application: offices,<br />

shops, meeting rooms, restaurants, hotels, clubs, gyms, and open plan areas.<br />

The Advanced FDTA Cassette range has now been extended to include new small<br />

capacity INVERTER systems starting at 1.8kW/2.0kW, and an extra high capacity<br />

system 14.3kW/16.2kW at the top end. (figures stated are for cooling/heating<br />

performance.<br />

7-Day Programmable Timer - now included in standard controls specification.<br />

The CoP (Coefficient of Performance) has been dramatically increased,<br />

up to 3.76 on some models. This means the system can deliver 3.76kW of<br />

heating, whilst consuming only 1.0kW of electrical power. This has been<br />

achieved by combining advanced <strong>Mitsubishi</strong> technology with R410A.


FDTA Cassette<br />

Air Conditioners and Heat Pumps for Commercial & Residential Applications<br />

Superior Controls Specification<br />

There has never been a multi function controller<br />

with the advanced sophistication of the new<br />

<strong>Mitsubishi</strong> RCE1. It combines all the basic user<br />

requirements – temperature setting, fan speed<br />

selection, mode, and timer settings, with a<br />

comprehensive range of service data functions,<br />

inverter compressor speed indication, fault<br />

diagnosis, and operational history.<br />

New Cassette Design: The improved air flow<br />

pattern through the unit, and the new design of<br />

high performance heat exchanger, have resulted<br />

in a pressure loss reduction, allowing the fan<br />

design to be optimised for significantly lower<br />

sound levels. The air discharge louver has been<br />

modified to minimise air smudging on the ceiling<br />

adjacent to the air outlets.<br />

Cassette units can be installed as single systems,<br />

or as multi systems, i.e. twin/triple/quad indoor<br />

units connected to one outdoor unit - ideal for<br />

large open plan areas, or irregular shaped rooms.<br />

Please refer to the Multi-System brochure for<br />

further details.<br />

RCE1 Wired Controller<br />

Timer Operation<br />

Time ... 8 9 10 11 12 13 14 15 16 ... 23<br />

Timer Timer Timer Timer<br />

RUN<br />

FDTA Technical Specification<br />

• 7-Day Programmable Timer<br />

• Two on/off settings each day<br />

• Different temperature for each set<br />

period<br />

• External timer/BMS switching for Group (up<br />

to 16 units)<br />

• Wall Controller - hard wired<br />

• Integral temperature sensor<br />

• Infra-red wireless controller optional<br />

• INVERTER technology on smaller models<br />

• Low profile attractive grey/white fascia panel<br />

• Improved anti-smudge air discharge<br />

• Low ambient control included<br />

• Auto re-start after power interruption<br />

• Reduced sound levels<br />

• Compatible with Multi Systems<br />

Benefits for the installer<br />

• Simplified interconnecting wiring -<br />

3-core + Earth<br />

• Pre-charged for 30 metres pipe length<br />

FDTA Cassette 4-Way<br />

FDTVA FDTVA FDTVA FDTA FDTA FDTA FDTA<br />

151 201 251 301 401 501 601<br />

HEN HEN HEN HEN HES HEN HES HES HES<br />

Power source 1 ph 1 ph 1 ph 1 ph 3 ph 1 ph 3 ph 3 ph 3 ph<br />

Type Inverter Inverter Inverter Constant Constant Constant Constant Constant Constant<br />

COOLING (nominal) max. kW 1.8 to 4.7 2.2 to 5.6 2.8 to 6.3 7.2 7.2 10.0 10.0 12.5 14.3<br />

UK Cooling (max) kW 4.56 5.43 6.11 7.0 7.0 9.7 9.7 12.1 13.9<br />

Energy label in cooling A A A A A C C C A<br />

HEATING (nominal) max. kW 2.0 to 5.4 2.5 to 6.3 3.1 to 7.1 7.3 7.3 11.2 11.2 13.6 16.2<br />

C.o.P 3.41 3.62 3.76 3.48 3.48 3.21 3.42 3.61 3.21<br />

Energy label in heating B A A B B C B A C<br />

ECA Listed • • • • • • • • •<br />

INDOOR UNIT H x W x D unit (mm) 270 x 840 x 840 270 x 840 x 840 270 x 840 x 840 270 x 840 x 840 270 x 840 x 840 295 x 840 x 840 295 x 840 x 840 365 x 840 x 840 365 x 840 x 840<br />

panel (mm) 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950<br />

Net weight kg 24+8 24+8 24+8 24+8 24+8 26+8 26+8 31+8 31+8<br />

OUTDOOR UNIT H x W x D (mm) 595 x 842 x 290 595 x 842 x 290 595 x 842 x 290 845 x 880 x 340 845 x 880 x 340 1050 x 920 x 340 1050 x 920 x 340 1300 x 970 x 370 1300 x 970 x 370<br />

Net weight kg 40 40 40 75 75 92 92 112 126<br />

Power Source Rating MCB A 15A 15A 15A 20A 15A/ph 40A 15A/ph 20A/ph 20A/ph<br />

Ref. max piping length m 40 40 40 50 50 50 50 50 50<br />

Enhanced Capital Allowance<br />

All FDTA models are registered on the Energy Technology List and qualify for 100%<br />

tax allowance on the first year, on the total cost of the products and installation<br />

costs (including pipework and electrical supply, materials, labour and design costs).<br />

(UK only).<br />

air conditioning

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!