Chapter 11: Approaches to SAN Management<br />

289<br />

Health monitoring<br />

Health monitoring works in conjunction with the agents that I mention in<br />

the preceding section. Because the agent talks to the components, the hub,<br />

switch, HBA, or storage array can give the agent an update on what it’s doing,<br />

how it’s performing, and whether anything is going on that the administrator<br />

needs to be warned about. Then the agent forwards this update to the<br />

management framework so that it can be logged and presented to the SAN<br />

administrator. Any changes in the status of any component on the SAN can<br />

be displayed on the SAN administrator’s console immediately, and then the<br />

administrator can take action.<br />

Levels of monitoring<br />

Health monitoring involves various levels of detail:<br />

✓ At the simplest level, you’re notified whether a component is up or<br />

down (in other words, on or off).<br />

✓ The next level gives some information on whether the status of the component<br />

is good or bad.<br />

A SAN switch, for example, can report that all its internal components<br />

are working properly and that the status is good. If one of its dual power<br />

supplies burns out but the switch is still operating, it reports that things<br />

are bad but that it’s still functioning.<br />

✓ The lowest level of monitoring reports details about a component — in<br />

the case of a switch power supply, for example, the actual voltage level<br />

coming in from the outlet.<br />

All these health-monitoring levels allow you to capture the status of everything<br />

in your SAN without having to run around the computer room checking<br />

the status lights on all your components. Your SAN management framework<br />

takes all these messages and converts them to events or icons on the administrator’s<br />

screen to show you what’s going on.<br />

In-band and out-of-band management<br />

You have two ways to communicate with your components to read their<br />

status or tell them to do something:<br />

✓ In-band management<br />

✓ Out-of-band management<br />

Figure 11-8 shows the two ways that your management server can communicate<br />

with your SAN components.