3.2. Mains Supply<br />

The <strong>Church</strong> has an incoming three phase mains electrical supply<br />

and a supply voltage of 237v. (Note the second meter appears to<br />

be <strong>for</strong> the phone mast). This voltage is higher than required and<br />

could explain some of the reason <strong>for</strong> the higher incidents of<br />

lighting replacement. The voltage can be reduced to around<br />

220V quite safely and without affecting the per<strong>for</strong>mance of any<br />

of the electrical equipment. Reducing the voltage will not only<br />

produce an energy saving but will also help to protect any<br />

lighting and sound equipment from problems associated with<br />

high voltage which can shorten their life. A simple 100A 3 phase<br />

unit can be obtained from SavaWatt controls (Campbell Hodgetts<br />

– 07767 306463)<br />

3.3. Small Power<br />

During the site visit it was noted that there are other small electrical usages, the most significant of<br />

which is likely to be the organ blower however this does have inverter drives on the motors and<br />

there<strong>for</strong>e no further recommendations are made in this regard.<br />