"WATERCHAMP"CONTROLLER<br />
OPERATINGINSTRUCTIONS<br />
4and6ZoneIndoor&Outdoor<br />
<strong>Irrigation</strong>Controllers<br />
CoveringModels:<br />
R-4,R-6,R-40,R-60<br />
WC-4IN,WC-6IN,WC-4OUT,WC-6OUT,<br />
CHAMPIONIRRIGATIONPRODUCTS<br />
1460NAUDSTREETLOSANGELES,CA90012<br />
1(800)33-CHAMP<br />
1
WARNING / CAUTION<br />
1.BeforeinstallingyourOutdoorWaterChamporWaterChampProfessional<br />
sprinklercontroller,turnoffyourbreaker/fusepaneltoavoidunnecessary<br />
electricalshock.Ifyouhavenoexperienceinconnectingyourelectrical<br />
powertoyourcontroller,then<strong>Champion</strong><strong>Irrigation</strong>Productsstrongly<br />
recommendshiringalicensedElectricianorLandscapeContractorto<br />
wireitforyou.<br />
2.Beforedigginganytrenchesforpipeorwiring,contactyourlocalutility<br />
companyforthelocationofanyundergroundpipesorhighvoltagepowerlines.<br />
Failuretodothiscancauseseriousinjuryand/orpropertydamage.Besafe!<br />
3.WhenconnectingthevoltagetoourOUTDOORmodelWaterChampor<br />
WaterChampProfessionalcontroller,besurethevoltageis110-120VoltsAC<br />
(220-240VoltsAConourexportmodel).Connectingthecontrollertohigher<br />
thanspeciiedvoltagewillcausethetransformertooverloadandburn.Check<br />
yourelectricalvoltage.<br />
4.<strong>Champion</strong>indoorplug-intransformerscannotbeexposedtomoistureor<br />
weather.Theyareforindooruseonly.Noneofourcontrollersshouldbe<br />
installedunderwater.Doingthiswillresultinseriouselectricalshock.Follow<br />
theinstructionsinbooklet.<br />
5.WheninstallingourIndoorWaterChamporWaterChampProfessional<br />
controllers,pleasenotethatindoormeansexactlythat,“INDOORS”.Installing<br />
underapatiocoverorawningisNOTindoors.Examplesof“Indoors”are<br />
garage,basementetc.Installingourindoorunitoutdoorswilldamagetheunit<br />
andvoidthewarranty.Thereisalsoapossibilityofelectricalshock.Ifyou<br />
needtoinstallaunitinanoutdoorlocation,thenpurchaseanoutdoormodel<br />
6.WaterChampandWaterChampProfessionalcontrollersaredesignedto<br />
operate24Voltautomaticsprinklervalves.Theyarenotdesignedtooperate<br />
thingslikefountains,landscapelighting,garagedoorsandotherthingsofthe<br />
sort.Usingthisproductforanythingotherthanitsintendedusecancause<br />
damagetotheunitorpropertyandwillvoidthewarranty.<br />
7.WaterChampandWaterChampProfessionalcontrollershavean"Off-Rain"<br />
setting.Thissettingpreventsthecontrollersfromrunningtheirprogramas<br />
scheduled.Theunitwillnotwateruntilthedialismovedfromthisposition.<br />
Landscapedamagemayoccuriftheunitisleftinthe"OffRain"positionduring<br />
warmorhotweatherorforextendedperiods.Ifyouwouldlikethecontrollers<br />
towaterasprogrammedbesuretoreturnthedialtothe"AllManual"or<br />
12:00position.<br />
2
DearCustomer,<br />
Thepeopleat<strong>Champion</strong><strong>Irrigation</strong>Productsthankyouforpurchasingthis<br />
product.Wetrustitwillgiveyouyearsofdependableserviceasitwasbuilt<br />
toveryhighstandards.Itistechnologicallystate-of-the-art,easytoprogram,<br />
andarealvalue.Ifyoushouldhaveanyquestionspleasecallusat(800)<br />
33-CHAMP[800-332-4267].The"WaterChamp"controllersareavailablein<br />
4and6zoneindoor&outdoormodels,andhave3independentprograms,<br />
A,B,andC,ofwhichanyonecanbeusedforthelawn,oneforshrubs,and<br />
oneprogramforadripsystem.Amongtheotherfeaturesandbenefits,the<br />
"WaterChamp"Controllershavethefollowing:<br />
* AlifetimecalendarforwateringonlyODDorEVENdaysintheevent<br />
ofaneedtoconformtolocalwaterrestrictions.<br />
* OFF/RAINswitchpositiontostopwateringduringrainydays.<br />
* 3MANUALRUNoptions-ALLMANUALwithProgramA,thenB,<br />
thenC;runjustProgramAorBorC;runanindividualzoneonly.<br />
* 4STARTTIMESforeachprogramfornewlyseededlawns,new<br />
sod,orhotweather.<br />
* WATERDAYSoptionsallowwateringspecificdaysoftheweekon<br />
SETDAYS,orwateronSKIPDAYSskippingfrom1to30days.<br />
AddtheODD/EVENoptiontowateronlyonoddorevencalendar<br />
daysifrequiredbylocalrestrictions.<br />
* ZONERUNTIMEallowsvalveruntimesfrom1minuteto1hourin<br />
1minuteincrementsand1hourto12hoursintenminuteincre<br />
ments.<br />
* %watering(waterbudgeting)allowsincreased(upto200%)or<br />
decreased(downto10%)valveruntimeswithoutreprogramming-<br />
greatforwaterconservation.<br />
* Automaticandinternalfeaturesincludeafactoryset(default)pro<br />
gramtowatereveryzonedailyfor10minutesstartingat5:00a.m.<br />
Internalswitch(SW2)willallowProgramCtoberunatthesame<br />
timeasProgramsAorB(dripsystemapplication).TheRAINtermi<br />
nalwillallowarainsensorshut-off.Nofuseisrequiredasthe<br />
controllerhasautomaticcircuitprotection,skipsanyshortedzone,<br />
andshowsshortedzoneasa'bad'zoneintheLCDdisplay.<br />
Pushingthesandtarrowstogethertestsallzonesforashort.An<br />
internallithiumbatterybacksupthecalendarandmemoryofyour<br />
programsforupto7years.TheRESETswitchallowsresettingthe<br />
controllerbacktothefactorysetdefaultprogram.<br />
* Allzoneruntimescountdownduringtheruncycle,andskipdays<br />
countdownastheday(s)pass.<br />
* Controllerwilloperateinauto-runfromanypositionoftherotarydial<br />
exceptOFF/RAIN.<br />
Your<strong>Champion</strong>controllerprovidestheconvenienceofautomaticwatering<br />
andtheflexibilitytomakethemostofourpreciouswaterresources.Your<br />
controllerwasdesignedtobeeasytoprogramandoperate.Pleasereferto<br />
thisguidetolearnthebestwaytoinstallanduseyourcontroller.<br />
3
TABLEOFCONTENTS<br />
INSTALLATION<br />
MountingYourController 5<br />
WiringYourValves 5<br />
WiringYourController 5<br />
ConnectingtheTransformer(IndoorModels) 6<br />
ConnectingtheTransformer(OutdoorModels) 6<br />
PROGRAMMINGYOURCONTROLLER<br />
ProgramsA,B,andC 6<br />
SettingtheCurrentCalendar 7<br />
FactorySet/DefaultProgram 7<br />
SettingaWateringSchedule 8<br />
SettingStartTimes 8<br />
SettingWateringDays 8<br />
SettingZoneRunTime 9<br />
EfficientRunTimes 9<br />
SettingAdditionalPrograms 10<br />
ImportantProgrammingNotes 10<br />
OPERATINGYOURCONTROLLER<br />
AutomaticOperation 11<br />
ManualOperation 11<br />
FEATURES<br />
Off/Rain 11<br />
%Watering/WaterBudgeting 12<br />
ZoneTest 12<br />
ResetButton 12<br />
INTERNALFEATURES<br />
RainSensor 12<br />
ProgramStackingSwitch(SW2) 13<br />
ADDITIONALFEATURES 13<br />
PROGRAMMATRIX 14<br />
TROUBLESHOOTINGTIPS 15<br />
4
INSTALLATION<br />
WheretoInstallYourIndoorController<br />
Locateyourcontrollerindoorsnearastandard110vACoutlet.The<br />
outletshouldnotbecontrolledbyaswitchorsharethesamecircuit<br />
withagaragedooropener,electricdryer,orotherlargeapplianceor<br />
inductivemotor.Thelocationshouldbeprotectedfrommoistureand<br />
temperaturesexceeding120 o Farenheit.<br />
MountingYourController<br />
Screwoneofthesupplied#8screwsintoawallateyelevel.Leave<br />
1/4"ofthescrewheadextendingfromthesurface.Useananchor<br />
boltfordrywallormasonry.Slipthebuttonholeopeningonthebackof<br />
theboxoverthescrewhead.Openthelowerdoor.Installtwomore<br />
screwsfromthefront,throughtheholesatthebottomofthebox.<br />
WiringYourValves(seefig.1)<br />
Usecolor-coded18gauge(16or14gaugecanalsobeused)plastic<br />
jacketedsprinklerwiretoconnectthecontrollertoyourvalves.Ifyou<br />
plantoburythewire,usearoutethatwillnotbedisturbedlaterby<br />
digging.Eachvalvehastwowires.Useonewireforpowerandone<br />
forcommon,itdoesn'tmatterwhichoneyouuse.<br />
Connectthecommonwiresfromallthevalvestooneofthecolor<br />
codedsprinklerwires(usuallythewhitewire).Connecttheotherwire<br />
fromeachvalvetoasinglecolorcodedwire.Usewirenutsorsolder<br />
tosecuretheconnections.Protectconnectionswithsiliconsealant<br />
orelectricaltape.<br />
WiringYourController(seefig.2)<br />
Openthelowerdooronyourcontroller.Usingasmallscrewdriver,<br />
attachthecommonwiretotheterminalmarked"COM."Attachthe<br />
wiretotheleftsideofthescrewforbetterholding,orwrapthewire<br />
aroundthescrew.AttachthewireforZone#1totheterminalmarked<br />
"V1".Attachtheremainingwiresthesameway.(Attachonlyone<br />
valveperterminal.)<br />
5
(InstructionsforPumpStartandMasterValveonly)Attachonewire<br />
fromthepumpstartrelayormastervalvetothe"MV"terminal,theother<br />
wiretothe"COM"terminal.Topreventdamagingyourpumpintheevent<br />
thedefaultprogramturnson,attachajumperwirefromanyunusedzone<br />
terminaltoanoperatingzoneterminal.Thiswaythepumpwillnotoperate<br />
againstaclosedsystem.<br />
ConnectingtheTransformer(IndoorModels)<br />
Attachthetransformerconnectortothetwopincircuitboardconnector.The<br />
connectoronlyfitsoneway.Besuretheribsonthetransformerconnectorfit<br />
overthespineonthecircuitboardconnector.DONOTforcetheconnectors<br />
together.Useonetransformerpercontroller.<br />
ConnectingtheTransformer(OutdoorModels)<br />
Note:OutdoorModelsHaveInternalTransformers!Turnoffthecircuit<br />
breakerforthe110voltACcircuitthecontrollerwillbetappedinto.Attach<br />
theblackwiretothe110volthotlead.Attachthewhitewiretothe110volt<br />
neutrallead.Attachthegreenwiretothegroundlead.Useaprofessional<br />
electricianifyouarenotcomfortablewithdirectwiringyourcontroller.<br />
UNDERGROUNDSPRINKLERSYSTEMS<br />
Therearethreecomponentsofanautomaticsprinklersystem.Thecontroller<br />
(brain),automaticvalves(zones),andthesprinklers.Thecontroller"tells"<br />
thevalveswhenandhowlongtosupplywatertothesprinklers.Eachvalve<br />
controlsagroupofsprinklersknownasazone.Eachvalveisconnected<br />
toanumberedterminalinthecontrollermarked1,2,3,etc.forthezone<br />
number.Thevalvesoperateinnumericalorderwithineachprogram,which<br />
iscalledacycle.<br />
EachProgramRequiresthreebasicinstructionsasfollows:<br />
* Whatdaystowater-calledWATERDAYS<br />
* Whattimeofdaytowater-calledSTARTTIMES<br />
* Howlongtowater-calledZONERUNTIME<br />
PROGRAMMINGYOURCONTROLLER<br />
ProgramsA,B,&C<br />
Yourcontrollerallowsyoutosetthreeindependentprograms:A,B,andC.<br />
Eachprogramcanhaveitsownsetofstarttimes,runtimesandwatering<br />
days.Usetheseprogramstosatisfythedifferentwateringneedsofyour<br />
landscape.Forexample,youmayuseprogramAtowaterthelawninthe<br />
morningeveryotherdayfortenminutesonlyineachlawnzone.Use<br />
programBforexample,towatershrubsonTuesdaysandSaturdaysforthirty<br />
minutesonlyineachshrubzone.<br />
6
UseprogramCfordripsystemwateringforexample,onceaweekforfour<br />
hoursandthirtyminutesonlyineachdripzone.(Whensettingdifferent<br />
programs,becarefultoavoidsettingastarttimeforoneprogramthatwill<br />
beginwhileanotherprogramisstillwateringunlessusingSW2(seepage13).<br />
Erraticoperationofthecontrollermayresultfromoverlappingprograms.)<br />
SettingtheCurrentCalendarTime,Month,Day,&Year<br />
StartprogrammingyourcontrollerbysettingtheCALENDARTIME(current<br />
timeA.M.orP.M.,MONTH[01=Jan.,02=Feb.,andsoon],DAY[dayofthe<br />
month],andYEAR[00=2000,andsoon]).<br />
* Turntherotarydialcounterclockwise(left)totheTIMEposition.The<br />
displaywillread'12:00A.M.'(forinitialsettingonly).Setthecurrent<br />
timebypushingthesortbuttonuntilthecorrectA.M.orP.M.time<br />
isshownintheLCDdisplay.<br />
* TurnthedialtoMONTHandsetthecurrentmonth.Forexample,'01'<br />
isJanuary,'02'isFebruary,and'12'isDecember.<br />
* TurnthedialtoDAYandsetthecurrentdayofthemonth,one(1)<br />
throughthirty-one(31).<br />
* TurnthedialtoYEARandsetthecurrentyear,startingat'00'isthe<br />
year2000andsoon.<br />
Thecalendarextendsfor50years,goingfarbeyondwhatisneeded,andis<br />
accurateforthelifeofthecontroller(includingleapyears).Withtheinternal<br />
lithiumbattery,allprogramsandcurrenttimewillberetainedforuptoseven<br />
(7)yearsorlongerevenwithoccasionalpowerinterruptions.Whenthe<br />
calendarisset,thecurrentdayoftheweekwillhaveabracketaroundit.<br />
[W]forexample.<br />
FactorySet/DefaultProgram<br />
Your"WaterChamp"Controllerisshippedfromthefactorywithapermanent<br />
programforeasyprogrammingandasabackupdefaultprogram.Every<br />
zonehasten(10)minutesruntimeandisassignedtoProgramA,scheduled<br />
towatereverydayat5:00A.M.Youcanprogramwhatyouwantoverthis<br />
factorysetprogram,butintheeventthattheACpowerisoffandthebackup<br />
lithiumbattery(7to9yearlife)isnolongerfunctioning,thisdefaultprogram<br />
wouldwateryouryardasdescribedaboveoncepowerwasrestored.<br />
7
SettingaWateringSchedule<br />
Your"WaterChamp"controllerhasprogramsA,B,andCwhichallowsyouto<br />
setthreeindependentprograms.Eachprogramcanhaveits'ownsetofstart<br />
times,runtimes,andwateringdays.Thedialselectsthedifferentprogram<br />
informationbysettingthePROGRAMswitchtothedesiredprogramtobeset<br />
oraltered.Usetheseprogramstosatisfythedifferentwateringneedsofyour<br />
landscape.DeterminewhatyouwouldliketodowithProgramA.Ifitistowater<br />
yourlawnsforexample,decidethenumberofstarttimesneeded(generallyone<br />
ortwo),andthedurationofwatering(generallyfifteenminutesorlessperzone<br />
unlessrotorsorimpactsareused).Thetotallengthofwateringtimewillbe<br />
equaltothesumofthewateringtimesforalltheoperatingzones.Watering<br />
shouldbedoneveryearlyinthemorningtoassureadequatewaterpressure,<br />
lesswinddispersal,diminishedchanceofleafburn,andreducedevaporation.<br />
Wateringatnightcanpromotefungusgrowth.<br />
SettingStartTimes<br />
NOTE:StarttimesareforprogramsA,B,&C,notindividualzones.<br />
* TurntherotarydialtoSTARTTIMESposition1.<br />
* MovethePROGRAMswitchlefttothe'A'position.<br />
* TosetSTARTTIME1(factoryset/defaultissetat5:00AM,suggest<br />
edsetting:between4:00A.M.and6:00A.M.)pushthes(toadvance)<br />
ort(torecede)buttonstochangethedisplayedstartingtime.<br />
* Usethesameproceduretosetasecondstarttimeifdesiredusing<br />
STARTTIME2.Generallysecondwateringsaresetfortheafternoon<br />
sobesuretocheckthatthecorrectA.M.orP.M.indicatorisshownin<br />
theLCDdisplay.<br />
* StartTimes3and4mightbeusedfornewlyseededlawnsornew<br />
sod.Theyarealsosetusingthesameprocedure.<br />
* Shouldyounolongerneedastarttime(i.e.newlyseededlawn<br />
matures),pushtheOFFbuttontocancel.Theyareretainedinthe<br />
memory.Ifyouwishtousethemagain,pushtheONbutton.<br />
SettingWateringDays<br />
InWATERDAYSyoumayuseeitherSETDAYS(7daysoftheweek)orSKIP<br />
DAYS(skipfrom0to30days)inanycombinationofProgramsA,B,orC.<br />
ProgramsAandBcanbeonSETDAYSandProgramCcanbeonSKIP<br />
DAYS.However,ODD/EVENcanonlybesetwhenusingSKIPDAYS,notwhen<br />
usingSETDAYS.<br />
Towateronspecificdaysoftheweek,rotatethedialtotheSETDAYSposition<br />
intheWATERDAYSsegmentofthedial.SMTWTFS(Sundaythrough<br />
Saturday)arethesevendaysoftheweekshowninthedisplay.<br />
8
Usethesbuttontoadvancethroughthedaysoftheweek(thetbuttonwill<br />
reversethroughtheweek).Theselecteddaywillblink.Ifyouwantthatparticular<br />
daytowater,pushtheONbuttonandabox(bracket)willappeararoundthat<br />
day.ToturnoffadaypresstheOFFbutton.Forexample,towateronMondays,<br />
Wednesdays,andFridays,thedisplayshouldshow:<br />
<br />
SMTWTFS<br />
Ifyouwantaconsistentnumberofdaysbetweenwatering,rotatethedialto<br />
SKIPDAYS(donotusetheSETDAYSposition).Withthissettingyoucanskip<br />
wateringfromone(1)tothirty(30)daysorsetat0towatereveryday.Ifyouset<br />
SKIP1DAY(S)youwillwatereveryotherday,ifyousetSKIP2DAY(S)youwill<br />
watereverythirdday,andsoon,uptoskipping30days(orchardsorvineyards).<br />
(Skip1daywillwatertomorrow)<br />
Ifyouhaverestrictionsfromyourwatercompanyandtheyrequirewateringon<br />
ODDorEVENcalendardays,setyourSKIPDAYSfirst,thenturnthedialto<br />
ODD/EVENandpushthesortarrowtotogglebetweenODDandEVEN<br />
settingsintheLCDdisplay.<br />
SettingZoneRunTimes<br />
NextmovetherotarydialtotheZONERUNTIMEsegmentofthecontrollerso<br />
thatitpointstothefirstzone(alsoknownasastation)thatoperatesavalvein<br />
theareayouwantwateredinProgramA(orwhicheverprogramyouaresetting).<br />
Thiswouldusuallybezone1.Determinehowlongyouwantthesprinklersto<br />
waterdependingonthetypeofsprinklers(impacts:30-45minutes,pop-ups:<br />
10-15minutes)andthetypeofvegetation(seeEFFICIENTRUNTIMESin<br />
thenextsectionformoredetail).Eachzonecanrunfrom1to60minutes<br />
in1minuteincrements,andfrom1hourto12hoursin10minuteincrements<br />
(generallyfordripsystems).Usethes(toincrease)ort(todecrease)buttons<br />
tosettheruntimeforeachzoneyouwishtouseintheprogramyouaresetting.<br />
(NOTE:Thefactoryset/defaultprogramhaseachzonesetat10minutesin<br />
ProgramA.Makesuretheruntimesforthezonesyouarenotusingaresetto<br />
OFFbypressingtheOFFbuttonwhiletherotarydialispointingtothatzone).<br />
EachzonecanONLYbeassignedtoONEprogram.Zone1forexample,can<br />
notbeusedinProgramAandagaininProgramBorC.The10minutedefault<br />
zoneruntimescanbechangedtoanythingfromthe10minutedefaultsetting<br />
downto1minute,orupto12hoursbyusingthesortbuttons,andassigned<br />
toanyprogramA,B,orCbymovingthePROGRAMswitchtotheappropriate<br />
programandmovingthesortbuttons.<br />
EfficientRunTimes<br />
Anefficientruntimedependsuponseveralfactors:thetypeofplantsbeing<br />
watered,temperature,humidity,soiltype,slopeoflandscape,andtypeof<br />
sprinklers.Formostlawns,theamountofwaterneededperweekrangesfrom<br />
about2"inhotclimatesdownto1/2"incoolerclimates.Treesandshrubshave<br />
deeperrootstructuresandrequirelongslowwatering,whichcanbestbeapplied<br />
byshrubsprays,abubbler,oradripsystem.<br />
9
Highhumidityreduceswaterdemands.Ifyoursoilissandy,oryouarewatering<br />
onaslope,waterfrequentlywithshortruntimes.Claysoilholdswaterbetter,<br />
sowaterlessoftenanduseshortruntimes.Formorepreciseguidelines,check<br />
withalocalnurseryorgardeningserviceregardingyourspecificneeds.<br />
Tolearntherateatwhichyoursprinklersapplywater,doa"CanTest".Place<br />
several1lb.coffeecansorothersimilarsizecontainersevenlyacrossyour<br />
lawn.Runyoursprinklersuntiltheaveragewaterdepthinthecontainers<br />
reaches1".Recordtheruntime.Divide60minutesbythetimeyoumeasured<br />
todeterminetheaverageinchesperhouryoursprinklersdistribute(e.g.with30<br />
min.filltime,60min.÷30min.=2inchesperhour).Usethisinformationto<br />
planyourwateringschedule.<br />
Plantsneedmorewaterduringhotweathermonthsandlessduringcoldweather<br />
months.Useyourcontroller'sWATERBUDGETING(%)featuretomakeeasy,<br />
one-stepseasonaladjustmentstoyourruntimes.<br />
SettingAdditionalPrograms<br />
WhenyouhavefinishedsettingthezoneruntimesforProgramA,movethe<br />
programselectorswitchtoProgramBifyoudesireaBprogramforshrubsora<br />
dripsystem.RepeatinstructionsforProgramAtosetProgramBbeginningwith<br />
STARTTIMES,thenWATERDAYS,thenZONERUNTIMES.Rememberto<br />
notoverlapSTARTTIMESbyaddingupthecombinedruntimesforallzones<br />
inProgramAandaddthatamounttoProgramA'sSTARTTIMEtodetermine<br />
theearliestSTARTTIMEforProgramB.Forexample,ifSTARTTIME1for<br />
ProgramAissetto4:00A.M.andZone1runsfor10minutes,Zone2for25<br />
minutes,Zone3for30minutes,andZone4for10minutes(allinProgramA)<br />
thenthecombinedtotalruntimeis75minutes,thereforeProgramBcouldnot<br />
startuntil75minutesormorepast4:00A.M.,sothefirstavailableSTARTTIME<br />
forProgramBwouldbe5:15A.M.<br />
ContinuingprogrammingyourWATERCHAMPcontrolleruntilyouhavecovered<br />
allProgramsA,B,and/orCSTARTTIMES,WATERDAYS,andZONERUN<br />
TIMESyouwish,thenreturntherotarydialtotheallmanualposition.<br />
ImportantProgrammingNotes<br />
TheProgramSwitchmustbeintheRUNpositionforautomaticormanual<br />
watering,andintheA,B,orCpositiontosetprogramSTARTTIMES,WATER<br />
DAYS,andZONERUNTIMES.<br />
Thestartofwateringisdelayedoneitherautomaticormanualrunsonevery<br />
zone/valvebyten(10)seconds.<br />
Note:theredLEDinthelowerleftcornerofthefaceplatelabellightsatthestart<br />
ofAUTO,MANUAL,orTESTfunctionsandstaysonwhileACcurrentisbeing<br />
suppliedtoanyterminal(aprogramisrunning).Theadvantageofthis10second<br />
delayisthedemandforelectricalcurrentdoesnotcomeonallatthesametime<br />
if2zonesorthepumpstartcomeonsimultaneously.<br />
10
11<br />
Italsoallowstimetodoavisualcheckofyourzonestoseeiftheyarewatering<br />
properly.Whenthecontrolleriswatering,thedisplaywillshowtheactivezone<br />
numberandthecorrespondingprogramthezonehasbeenprogrammedinto<br />
andcountdowntheremainingruntimewhenrunningintheAUTOposition.To<br />
stopwateringatanytimepushtheOFFbutton.<br />
OPERATINGYOURCONTROLLER<br />
AutomaticOperation<br />
WheneveryourcontrollerisprogrammedwithSTARTTIMES,WATERDAYS,<br />
andZONERUNTIMESitisreadytoautomaticallywater(solongastherotary<br />
dialisnotpointingtotheOFF/RAINposition).<br />
ManualOperation(Turningonyoursprinklersrightnow)<br />
Therearethreewaystoturnonyoursprinklersmanually:<br />
1. PRESETALLPROGRAMWATERING:withtherotarydialattheALL<br />
<br />
MANUALposition,pushtheRUNbutton.Zones1to4(or1to6<br />
<br />
onsixstationmodels)willwaterthetimeyousetinZONERUNTIME<br />
<br />
inProgramA,thenB,thenC.(Remembereachzonecanonlybe<br />
<br />
assignedtooneofthethreeprogramsA,B,orC).<br />
2. PRESETINDIVIDUALPROGRAMWATERING:Withtherotarydial<br />
<br />
intheALLMANUALposition,pushthedesiredProgramA,B,orC<br />
<br />
buttontowaterjustthezonesinthatprogramthepresetruntimes<br />
<br />
youprogrammed-rememberthe10seconddelaybeforethesprin<br />
<br />
klersstartwatering.(Note:%WateringchangesruntimesinManual<br />
<br />
#1above,butnot#3"ManualWateringASingleZone")<br />
3. MANUALWATERINGASINGLEZONE:Movetherotaryswitchto<br />
<br />
thezoneyouwishtowater.Ifyouwishtowaterthezoneforthe<br />
<br />
sameamountoftimeyouhavealreadyprogrammed,pushtheRUN<br />
<br />
buttonthenmovethedialbacktotheALLMANUALposition.Ifyou<br />
<br />
wishtorunthezonemoreorlessthantheprogrammedruntime,<br />
<br />
slidetheprogramswitchtotheprogramthatthezoneisinanduse<br />
<br />
thes(toincrease)ort(todecrease)buttonstoenterthetimeyou<br />
<br />
wishtorunthenmovetheprogramswitchbacktotheRUNposition<br />
<br />
andpresstheRUNbuttonthenmovethedialbacktotheALLMANU<br />
<br />
ALposition.Afterwatering,reprogramthezonetotheProgramrun<br />
<br />
timeyouwish.<br />
NOTE:TostopwateringatanytimepresstheOFFbuttonwiththedialintheALL<br />
MANUAL/RUNposition.<br />
FEATURES<br />
OFF/RAIN<br />
TurntherotarydialtotheOFF/RAINpositionifyoudonotwanttowaterdue<br />
torainorforanyotherreason.Thetimeandallprogramswillberetained,<br />
butelectricitywillnotgotothevalvestoturnthemon.Besuretoturnthe<br />
rotarydialoutoftheOFF/RAINpositionandbacktotheALLMANUALposition<br />
towateragain.
%Watering/WaterBudgeting<br />
Atabouttheone(1)o'clockpositionontherotarydialbetweenALLMANUAL<br />
andSTARTTIME1positionsisthe%sign.InthispositiontheLCDreads100%<br />
whichmeansthezoneswatertheexacttimeyouenteredintotheprogram.With<br />
thisfunction,youcanalteryourzoneruntimestomatchthemoisturedemand<br />
basedonthecurrentweather.Ifitishotanddry,youcanincreasetheruntime<br />
-coldanddamp,youcandecreasetheprogrammedruntime.Thes(up)and<br />
t(down)arrowscontrolthepercentageadjustmentupto200%ordownto10%<br />
in10%increments(steps).Foranypercentageotherthan100%,the%sign<br />
willremainintheLCDreadoutindicatingapercentageruntimeadjustment.As<br />
anexample,ifyouhadten(10)minutesonzone1andset%wateringat50<br />
%,zone1wouldwaterforfive(5)minutes.Allzonesinallprogramsareinan<br />
overridewith%watering.Itisabeneficialtooltouseforwaterconservation.<br />
Ifyoureturn%backto100%,theoriginalzoneruntimesarestillprogrammed.<br />
Thisistheeasiestwaytochangethelengthoftimeyouwater.With%watering,<br />
zoneruntimescangoasshortas10%ofone(1)minute(equivalenttosix<br />
seconds)fornurseryapplicationornewlyseededlawns.<br />
ZoneTest<br />
Bypushingboths (up)andt (down)arrowsatthesametime,azonetest<br />
startswithzone1tocheckifthereisabadzone,ashortonthewires,ora<br />
faultysolenoid.Thetesthasaten(10)seconddelaythencountsdownten(10)<br />
secondsintheLCD,thenmovestozone2andsoforth.Ifashortexists,a<br />
badzone#willbeindicatedontheLCD.Ifmultiplezonesareshorted,thebad<br />
zoneswillbeindicatedintheLCD.Badzoneswillbeskippedinthewatering<br />
cycleandreporteduntilfixed.<br />
ResetButton<br />
Ifyouwishtoresetoreraseallprogramsyouentered,besuretherotarydial<br />
isintheRUN/ALLMANUALposition,thenpushtheRESETbutton(locatedjust<br />
totheleftofthePROGRAMselectorswitch)withapentip.Yourcontroller<br />
willthencontainonlythefactorypresetprogram.Youcanthenreprogramthe<br />
CALENDARandanynewschedulesyouwish.<br />
INTERNALFEATURES<br />
Theterminalstripappearsasfollows:<br />
RainSensor<br />
TheUshapedconnectorwiremustremainconnectedbetweentheCOMand<br />
RAINterminalswhenarainsensorisnotinuse.Disconnectthewireandsaveit<br />
beforeconnectingarainsensor.ConnectonesensorwiretotheRAINterminal<br />
andtheothertotheCOMterminal.<br />
12
<strong>Champion</strong><strong>Irrigation</strong>doesnotmanufacturerainsensorssotheymustbe<br />
purchasedseparately.Followspecificinstructionssuppliedwiththerain<br />
sensor.<br />
SW2(Switch#2)<br />
SW2allowszonesinProgramCtorunatthesametimeaszonesin<br />
ProgramsAorBfordripsystemswhenitisplacedinthedownposition.<br />
Intheuppositiontheprogramsruninchronological(earliestclocktime)<br />
order.<br />
ADDITIONALFEATURES<br />
Nobackupbatteryneedstobepurchased.Aninternallithiumbattery<br />
issupplied.Theexpectedlifeofthebatteryisuptoseven(7)ormore<br />
years.Thebatterybacksupthecustomerenteredprograms(memory)<br />
andclocktimeintheeventofatemporaryACpowerfailure.<br />
Nofuseisrequiredwiththiscontroller.Itisstate-of-the-arttechnology<br />
withautomaticcircuitsurgeprotection,automaticrestart,andoverrideof<br />
ashortedzone.Thesefeaturescangiveyougreaterconfidencethatyou<br />
cangoawayonvacationandyouryardwillgetwatered.<br />
Theindoorandoutdoortransformeroutputis800mA(.8A/21.2VA)<br />
whichissufficienttopowertwo(2)solenoidsandamastervalve(pump<br />
startrelaylimitedtoamaximum35watts)simultaneouslywiththeten<br />
(10)seconddelayfeature.<br />
Your"WaterChamp"controllerwill"stack"programstarttimesandruns<br />
logically.Starttimesarechronological(earliestclocktime)andrununtil<br />
aprogramfinishesintheeventyouprogrammedlongerruntimesthan<br />
canfinishbeforethenextstarttime.Youcouldalsoextendruntimes<br />
intoanotherprogramwith%watering/WaterBudgeting.Yourcontroller<br />
willstackorholdthissecondprogramandstartitwhenthefirststart<br />
timeprogramfinishes.<br />
Programscouldrunpastmidnight(i.e.longdripsystemprograms).The<br />
exceptiontothisisifWATERDAYSaresetonSKIPDAYSandthe<br />
ODD/EVENfeatureisactivated.Inthiscase,anyremainingprogram<br />
runtimewouldbecanceledatmidnightsoasnottobeinviolationof<br />
anywaterrestrictions.<br />
13
SOLUTIONSTOCOMMONPROBLEMS<br />
Forfurtherassistance,call<strong>Champion</strong>'sTechnicalSupport<br />
departmentat:(800)33-CHAMPHours:8:00AM-4:30PMPST.<br />
VOLTAGESPECIFICATION:<br />
TransformerInput:110VAC50/60Hz<br />
ControllerOutput:26.5VAC800mA(8A/19.2VA)<br />
OPERATINGTEMPERATURE:32 O F-140 O F<br />
BACKUPBATTERY:Replaceable3voltLithium(PanasonicCR2032)<br />
WARRANTY:Limited3year<br />
15
LIMITEDWARRANTY<br />
<strong>Champion</strong><strong>Irrigation</strong>Productshereinaftercalled“<strong>Champion</strong>”warrantsthatpartsmanufacturedbyitshallbefreefromdefectsin<br />
materialandworkmanship,undernormaluseandservice,fora<br />
periodofthreeyears(iveyearsondomesticbrassproducts)from<br />
dateofpurchasetoitstradecustomers.Thisthree-yearperiodshall<br />
beknownasthe“warrantyperiod”.<strong>Champion</strong>willfurnishorrepair<br />
partsfoundtobedefective,duringthewarrantyperiod,atnocharge<br />
underourdefectivereturnprocedure.<strong>Champion</strong>’sliabilityissolely<br />
limitedtooriginalcostoftheparts,andnopaymentwillbemade<br />
forconsequentialorincidentalcostsordamagescausedbyproduct<br />
failure.<br />
<strong>Champion</strong>doesnotassumeliabilityfordefectiveproductsnot<br />
manufacturedorsuppliedbyus,eventhoughsuchproductsmaybe<br />
usedinconjunctionwithourown.<strong>Champion</strong>assumesnoliabilityfor<br />
damagessustainedintheadoptionoruseofourengineeringdata.<br />
<strong>Champion</strong>reservestherighttoredesign,alterormodifyitsproducts<br />
withoutincurringliabilityforobsoleteparts,orproductinventory.No<br />
agentorrepresentativeof<strong>Champion</strong>hastheauthoritytowaiveor<br />
alterthisprintedwarranty,ortomakeanyrepresentationorwarranty<br />
notcontainedhereinortoextendthiswarrantytoanyoneotherthan<br />
<strong>Champion</strong>’stradecustomers.Thiswarrantyshallnotbedeemeda<br />
consumerwarrantyandshallnotextendtoanyoneotherthanthose<br />
whopurchaseproductsfrom<strong>Champion</strong>forresale.Theforegoing<br />
warrantiesareexclusiveandareinlieuofallotherwarranties,<br />
whetherwrittenoralorimplied,includingwarrantyofmerchantability<br />
inotherrespectsthanexpresslysetforthaboveandwarrantyof<br />
itnessforaparticularpurpose.<br />
16