A C C E S S O R I E S<br />

Capillary <strong>Accessories</strong><br />

Capillary Connectors<br />

Universal Capillary Connectors<br />

• One size fits tubing from 0.25mm i.d. to 0.53mm i.d.<br />

• Available in straight or Y configurations<br />

Capillary connectors form a gas-tight seal when<br />

heated to typical <strong>GC</strong> temperatures. The angled<br />

connectors conform to the curvature of a fused silica<br />

capillary column. To create a permanent seal, add a<br />

small amount of polyimide resin to the outside of the<br />

capillary tube before inserting. Order under "<strong>Accessories</strong>"<br />

below.<br />

Universal Straight Connector<br />

CONNECTORS<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Straight Connectors<br />

Fused Silica<br />

Universal Straight Connector 5 20400<br />

Universal Straight Connector 25 20401<br />

Angled Universal Connector 5 20694<br />

Angled Universal Connector 25 20695<br />

Borosilicate<br />

Universal Straight Connector 5 20490<br />

Universal Straight Connector 25 20492<br />

Y-Connectors<br />

Fused Silica<br />

Universal Y-Connector 1 20405<br />

Angled Universal Y-Connector 1 20500<br />

Borosilicate<br />

Universal Y-Connector 1 20480<br />

Universal Y-Connector 5 20482<br />

<strong>Accessories</strong><br />

Polyimide Sealing Resin 5g 5825<br />

0017<br />

Featherweight Capillary Union<br />

• Lightweight<br />

• High temperature Vespel ®<br />

construction<br />

• Accommodates all tubing sizes<br />

FEATHERWEIGHT CAPILLARY UNION<br />

DESCRIPTION PART NO. PRICE<br />

Featherweight Union with 2 Nuts* 28990<br />

Vespel ® Ferrules for Use with Featherweight Union<br />

Vespel ® Ferrule, 0.8mm i.d. 28992<br />

Vespel ® Ferrule, 0.5mm i.d. 28993<br />

Vespel ® Ferrule, 0.4mm i.d. 28994<br />

*Order ferrules separately.<br />

Fused Silica Outlet Splitters<br />

• Accommodates capillaries<br />

from 0.22 to 0.32mm i.d.<br />

and provides a 1:1 ratio<br />

• Includes a glass-lined SS<br />

bulkhead union, a 0.4mm<br />

6628<br />

i.d. two-hole Vespel ®<br />

graphite ferrule and two lengths of deactivated fused<br />

silica tubing<br />

Use this inert outlet splitter with two detectors or<br />

one detector and a sample collection device.<br />

OUTLET SPLITTER<br />

DESCRIPTION PART NO. PRICE<br />

Outlet Splitter 14898<br />

5717<br />

Valco ® Zero-Dead Volume Union<br />

Use these stainless steel unions to make connections with fused silica<br />

capillaries. Unions feature specially designed Vespel ® /graphite ferrules and<br />

are bored through. Table 1 shows the parts needed for different connections.<br />

6021<br />

Table 1<br />

CONNECT FROM: TO 0.25MM I.D. FUSED SILICA TO 0.32MM I.D. FUSED SILICA TO 0.53MM I.D. FUSED SILICA TO 1/16” SS TUBING<br />

0.25mm i.d. Fused Silica 9068 9068 + 907110 45849 + 907010 + 903410 45849 + 907010<br />

0.32mm i.d. Fused Silica 9069 + 907010 9069 45849 + 907110 + 903410 45849 + 907110<br />

0.53mm i.d. Fused Silica 45849 + 907010 + 903410 45849 + 907110 + 903410 9031 45835 + 903410<br />

1/16" SS Tubing 45849 + 907010 45849 + 907110 45835 + 903410 45835<br />

VALCO ® ZERO-DEAD VOLUME UNIONS<br />

DESCRIPTION AND VALCO ® NO. PART NO. PRICE<br />

Zero Dead-Volume Unions<br />

1/32", 0.4mm (Valco ® ZU.5TFS.4) 9068<br />

1/32", 0.5mm (Valco ® ZU.5TFS.5) 9069<br />

1/16", 0.8mm (Valco ® ZU1TFS.8) 9031<br />

1/16" - 1/32", 1/32" Bore (Valco ® ZRU1.5T) 45849*<br />

1/16", 1/16" Bore (Valco ® ZU1T) 45835*<br />

© Copyright 2004 Alltech Associates, Inc.<br />

VALCO ® REDUCING FERRULES<br />

DESCRIPTION AND VALCO ® NO. PART NO. PRICE<br />

Valco ® Reducing Ferrules<br />

1/32" to 0.4mm (Valco ® FS.4), 10/pk 907010<br />

1/32" to 0.5mm (Valco ® FS.5), 10/pk 907110<br />

1/16" to 0.8mm (Valco ® FS1.8), 10/pk 903410<br />

* Includes 2 stainless steel ferrules.<br />

Contact your Alltech office or distributor for current or local prices.<br />

385


Capillary <strong>Accessories</strong><br />

A C C E S S O R I E S<br />

Capillary Guards & Tubing<br />

386<br />

Universal Guard Column Kits<br />

• Universal kits connect to any capillary column<br />

• Guard columns are<br />

deactivated<br />

Universal guard<br />

column kits contain<br />

three - 5m deactivated<br />

capillaries, three-universal fused silica connectors,<br />

ceramic cutter, and instructions. Order sealing resin<br />

separately under “<strong>Accessories</strong>” to reinforce connections.<br />

Replacement kit parts are available below.<br />

UNIVERSAL GUARD COLUMN KITS<br />

DESCRIPTION PART NO. PRICE<br />

Universal Guard Column Kits<br />

0.53mm Universal Guard Column Kit 13992<br />

0.32mm Universal Guard Column Kit 13998<br />

0.25mm Universal Guard Column Kit 14005<br />

Replacement Parts<br />

Universal Connectors, 5/pk 20400<br />

Angled Universal Connector, 5/pk 20694<br />

5m x 0.53mm i.d. Capillaries, 5/pk 13990<br />

5m x 0.32mm i.d. Capillaries, 5/pk 13999<br />

5m x 0.25mm i.d. Capillaries, 5/pk 14007<br />

<strong>Accessories</strong><br />

Polyimide Sealing Resin, 5g 5825<br />

20X Magnifier 3163<br />

Deactivated Guard Columns<br />

• Three different deactivation polarities<br />

• Chemically inert<br />

These guard columns<br />

protect your analytical column<br />

by collecting non-volatile,<br />

pyrolyzable, or particulate<br />

contamination.<br />

DEACTIVATED GUARD COLUMNS<br />

DESCRIPTION PART NO. PRICE<br />

Non-Polar<br />

0.25mm x 5m 19063<br />

0.32mm x 5m 19064<br />

0.53mm x 5m 19065<br />

Intermediate Polar<br />

0.25mm x 5m 19054<br />

0.32mm x 5m 19055<br />

0.53mm x 5m 19056<br />

Polar<br />

0.25mm x 5m 19057<br />

0.32mm x 5m 19058<br />

0.53mm x 5m 19059<br />

© Copyright 2004 Alltech Associates, Inc.<br />

6630<br />

6624<br />

Fused Silica Capillary Tubing<br />

• Deactivated and undeactivated tubing available<br />

• Available mounted on a cage<br />

Alltech provides the<br />

finest quality fused<br />

silica capillary tubing<br />

either untreated or<br />

deactivated by our<br />

proprietary high<br />

temperature process.<br />

Use tubing to prepare<br />

your own capillaries or<br />

guard columns.<br />

FUSED SILICA CAPILLARY TUBING<br />

I.D. QTY. LENGTH PART NO. PRICE<br />

Deactivated Tubing with Cage<br />

0.18mm — 10m 602026<br />

0.18mm — 20m 602028<br />

0.18mm — 40m 602029<br />

0.25mm — 15m 602915<br />

0.25mm — 30m 602930<br />

0.25mm — 60m 602960<br />

0.32mm — 15m 603915<br />

0.32mm — 30m 603930<br />

0.32mm — 60m 603960<br />

0.45mm — 15m 602030<br />

0.45mm — 30m 602032<br />

0.45mm — 60m 602034<br />

0.53mm — 15m 605915<br />

0.53mm — 30m 605930<br />

0.53mm — 60m 605960<br />

Deactivated Tubing, Without Cage<br />

0.05mm per meter 602038<br />

0.10mm — per meter 602037<br />

0.18mm — per meter 602010<br />

0.25mm — per meter 602640<br />

0.25mm x 1m 5/pk — 5827<br />

0.25mm x 2m 5/pk — 5829<br />

0.32mm — per meter 603640<br />

0.32mm x 1m 5/pk — 5831<br />

0.32mm x 2m 5/pk — 5833<br />

0.45mm — per meter 602012<br />

0.53mm — per meter 605640<br />

0.53mm x 1m 5/pk — 5832<br />

0.53mm x 2m 5/pk — 5834<br />

Undeactivated Tubing, Without Cage<br />

0.05mm — per meter 602035<br />

0.10mm — per meter 602036<br />

0.18mm — per meter 19603<br />

0.25mm — per meter 602600<br />

0.32mm — per meter 603600<br />

0.45mm — per meter 19602<br />

0.53mm — per meter 605600<br />

Contact your Alltech office or distributor for current or local prices.<br />

6631


A C C E S S O R I E S<br />

Capillary <strong>Accessories</strong><br />

Capillary <strong>Accessories</strong><br />

Capillary Cages<br />

These cages are made of a<br />

heavy gauge stainless steel and are<br />

electropolished to prevent abrasion.<br />

All are 7 inches in diameter.<br />

CAPILLARY CAGES<br />

DESCRIPTION PART NO. PRICE<br />

7" x 3/4" Cage 75200<br />

7" x 1-1/4" Cage 75201<br />

7" x 1-3/4" Cage 75202<br />

High Temperature String, 10ft 6344<br />

Capillary Column Washer<br />

This easy to use column washer is designed<br />

for solvent flushing of bonded or crosslinked<br />

fused silica capillaries. It is made of<br />

heavy duty glass and will hold up to 20mL of<br />

solvent. Maximum pressure is 125psig. Order<br />

appropriate sized ferrules separately below.<br />

CAPILLARY COLUMN WASHER<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Capillary Column Washer ea 5819<br />

Ferrules<br />

1/8" to 0.4mm VG1 10 200/0.4-VG1<br />

1/8" to 0.5mm VG1 10 200/0.5-VG1<br />

1/8" to 0.8mm VG1 10 200/0.8-VG1<br />

For a listing of suitable solvents for various<br />

stationary phases, request Data Sheet 5819.<br />

5715<br />

5719<br />

Capillary Endcaps<br />

Increase column life by preventing<br />

contaminants from entering column<br />

during storage.<br />

CAPILLARY ENDCAPS<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Fused Silica 2 20699<br />

Fused Silica 20 20701<br />

Silicone 10 4018<br />

Split-Vent Trap Kit<br />

• Charcoal filter cartridges are<br />

economical and easy to replace<br />

• Adsorbs toxic vapors<br />

• Connects directly to Agilent <strong>GC</strong>’s<br />

Alltech’s split-vent trap kit effectively adsorbs<br />

toxic or noxious vapors that might otherwise be<br />

released into the workplace. The trap has a 1/8"<br />

fitting to connect directly to Agilent <strong>GC</strong>’s and can<br />

be adapted for use with most other <strong>GC</strong>’s.<br />

The split-vent trap features a corrosionresistant<br />

base and a disposable NIOSH-type<br />

charcoal filter cartridge that is easy to replace.<br />

Order replacement cartridges below.<br />

What’s included: split-vent trap, three<br />

charcoal cartridges, cartridge scorer, and tip<br />

breaker.<br />

SPLIT-VENT TRAP KIT<br />

DESCRIPTION PART NO. PRICE<br />

Split-Vent Trap Kit 5870<br />

Replacement Charcoal Cartridge, 10/pk 5872<br />

1/8" Stainless Steel Union 14165<br />

5702<br />

6632<br />

How much solvent is needed to wash your column? Refer to the table below.<br />

Approximate Column Volume Required<br />

LENGTH 0.25MM I.D. 0.32MM I.D. 0.53MM I.D.<br />

10m 0.5mL 0.8mL 2.2mL<br />

15m 0.7mL 1.2mL 3.3mL<br />

25m 1.2mL 2.0mL 5.5mL<br />

30m 1.5mL 2.4mL 6.6mL<br />

50m 2.5mL 4.0mL 11.0mL<br />

60m 2.9mL 4.8mL 13.2mL<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

387


Packed <strong>Accessories</strong><br />

A C C E S S O R I E S<br />

388<br />

Packing <strong>Accessories</strong><br />

Air/Vacuum Pump<br />

• Oil-less operation<br />

• Portable and reliable<br />

This compact rotary vane<br />

air/vacuum pump will deliver 1<br />

liter per minute of oil free air<br />

at 15psig. It features graphite<br />

5083<br />

vanes and sealed-for-life ball bearings. The maximum<br />

vacuum is 20" (508mm) Hg continuous. Pump measures<br />

6-7/16" H x 5-5/8" W x 12" L (163.51mm H x 142.88mm<br />

W x 304.8mm L) and weighs 10lbs (4.54kg).<br />

What’s included: muffler, filter, 1/4" MPT ports, 10ft<br />

power cord with US standard plug.<br />

AIR/VACUUM PUMP<br />

DESCRIPTION PART NO. PRICE<br />

Air/Vacuum Pump, 115V 1531<br />

<strong>Accessories</strong><br />

Pressure Relief Valve 1534<br />

Vacuum Gauge 1536<br />

Pressure Gauge 1537<br />

Nalgene Vacuum Tubing, 1/4" i.d. x 5/8" o.d., 5ft 1599<br />

Attachable Funnel<br />

This anodized aluminum funnel<br />

attaches easily to 1/8" and 1/4" o.d.<br />

glass and metal tubing—ideal for column<br />

packing. Funnel can be disassembled<br />

for cleaning. Order adapters separately<br />

to attach funnel to columns with fittings<br />

already connected. Replacement o-rings are<br />

also available below.<br />

<strong>GC</strong> Column Vibrator<br />

ATTACHABLE FUNNEL<br />

DESCRIPTION PART NO. PRICE<br />

Attachable Funnel 4008<br />

Adapters<br />

for 1/8" Column 4050<br />

for 3/16" Column 4052<br />

for 1/4" Column 4054<br />

for 3/8" Column 4056<br />

Replacement O-rings, 12/pk 4010<br />

This vibrator is ideal for use when filling<br />

<strong>GC</strong> columns, including glass columns. This<br />

two-speed unit comes supplied with a 7-foot<br />

cord and US standard plug.<br />

<strong>GC</strong> COLUMN VIBRATOR<br />

DESCRIPTION PART NO. PRICE<br />

110V 4012<br />

© Copyright 2004 Alltech Associates, Inc.<br />

5079<br />

6660<br />

Premium Glass Wool<br />

Untreated - A soft fine denier Pyrex <br />

wool, primarily used for non-chromatographic<br />

applications.<br />

Silane Treated - Fine wool treated with dimethyldichlorosilane<br />

(DMDCS) to yield an inert material<br />

that won't decompose sensitive compounds. This<br />

material is ideal for most chromatographic applications.<br />

Phosphoric Acid (H3PO4), Treated - For analysis<br />

of acidic compounds such as free acids, phenols and<br />

glycols.<br />

Quartz Wool - Made from high-purity quartz,<br />

extremely low in metallic oxide impurities.<br />

PTFE Wool - Commonly used as a plug for packed<br />

columns when analyzing for low levels of sulfur.<br />

Pesticide Grade Glass Wool - A superbly inert glass<br />

wool ideal for use with electron capture, nitrogenphosphorous,<br />

flame photometric, alkali-bead flame and<br />

all electrolytic detectors.<br />

Glass Wool Tools<br />

Glass Wool Inserter/ Remover<br />

Wool Inserter<br />

PREMIUM GLASS WOOL<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Glass Wool<br />

Untreated Glass Wool 50g 4035<br />

Silane Treated Glass Wool 50g 4037<br />

Silane Treated Glass Wool 250g 4038<br />

H3PO4 Treated Glass Wool 25g 4039<br />

Quartz Wool 10g 4033<br />

Silane Treated Quartz Wool 10g 4233<br />

PTFE Wool 10g 4736<br />

Pesticide Grade Glass Wool 10g 4034<br />

Glass Wool Tools<br />

Glass Wool Inserter/Remover 2 6292<br />

Wool Inserter ea 6285<br />

Delrin ® Plugs<br />

• Use these plugs to seal the ends of<br />

columns<br />

Simply slip plug into your ferrule and<br />

nut, and attach to your fittings. Ferrules<br />

will not lock in place. Plugs are reusable.<br />

DELRIN ® PLUGS<br />

SIZE QTY. PART NO. PRICE<br />

1/16" 25 2898<br />

1/8" 25 2900<br />

1/4" 25 2902<br />

Contact your Alltech office or distributor for current or local prices.<br />

5075<br />

5088<br />

5089<br />

5087


A C C E S S O R I E S<br />

Packed <strong>Accessories</strong><br />

Packing <strong>Accessories</strong><br />

<strong>GC</strong> End Caps<br />

These end caps are nonshredding,<br />

flexible, and easily applied<br />

5085<br />

and removed. They provide a positive barrier to<br />

moisture and air. The 5/16" size fits over 1/4" columns<br />

that have ferrules swaged on the ends. The 3/16" size<br />

fits 1/8" columns with ferrules in place.<br />

<strong>GC</strong> END CAPS<br />

TUBE O.D. QTY. PART NO. PRICE<br />

1/16" 100 4020<br />

1/8" 100 4021<br />

3/16" 100 4022<br />

1/4" 100 4023<br />

5/16" 100 4025<br />

3/8" 100 4024<br />

1/2" 100 4026<br />

Glass Column Repair Kits<br />

This repair kit includes a 1ft<br />

(30.5cm) piece of shrinkable TFE-FEP<br />

tubing that encapsulates the broken<br />

section creating a tight and reliable<br />

seal.<br />

Easy to apply, just slip over one end<br />

of the broken tubes, butt the tubes,<br />

and heat to 330°C with a heat gun.<br />

GLASS COLUMN REPAIR KITS<br />

TUBING SIZE PART NO. PRICE<br />

Glass Column Repair Kits<br />

Up to 0.036" (0.91mm) 5800<br />

Up to 0.060" (1.52mm) 5801<br />

Up to 0.130" (3.30mm) 5802<br />

0.125" (3.18mm) to 0.250" (6.35mm) 5803<br />

Heat Gun<br />

110V 2518<br />

220V 2518-220V<br />

Column Tags<br />

Use these aluminum tags to create<br />

a permanent heat resistant record of<br />

pertinent column information. Writing<br />

surface of tag is 1" x 2" (25.4 x 50.8mm). Order a<br />

Vibrograver at right to permanently inscribe the tags.<br />

COLUMN TAGS<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Embossed <strong>GC</strong> Tags 100 8011<br />

Embossed <strong>GC</strong> Tags 25 8012<br />

Embossed LC Tags 25 8005<br />

Plain Tags 100 8009<br />

© Copyright 2004 Alltech Associates, Inc.<br />

5082<br />

5074<br />

Pressed Frits<br />

These frits are precisionfabricated<br />

from Type 316 stainless<br />

steel and are ideal for sealing the<br />

ends of <strong>GC</strong> columns.<br />

Pressed frits are easy to install.<br />

Drill the column ends to the<br />

proper diameter and depth using<br />

the drill bits sold below. Rest<br />

the frit on top of the tubing and<br />

gently tap it into place.<br />

PORE<br />

DIAMETER<br />

QTY.<br />

Pressed<br />

Frits<br />

STAINLESS STEEL PRESSED FRITS<br />

FOR USE WITH 1/8"<br />

O.D. TUBING<br />

FOR USE WITH 1/4"<br />

O.D. TUBING<br />

0.5µm 25 702625 —<br />

2.0µm 25 703425 703525<br />

5.0µm 25 702825 702925<br />

10.0µm 25 703025 703125<br />

20.0µm 25 703225 703325<br />

Drill Bits<br />

These drill bits are specifically<br />

designed to prepare tubing for<br />

frit installation. They include a<br />

bushing that acts as a stop to control<br />

the depth of the hole.<br />

DRILL BITS<br />

Column<br />

Contact your Alltech office or distributor for current or local prices.<br />

1050<br />

PRICE<br />

DIAMETER QTY. PART NO. PRICE<br />

for 1/8" Frits ea 7032<br />

for 1/4" Frits ea 7033<br />

Vibrograver<br />

Use for engraving or<br />

column packing. A carbide<br />

point is included. Remove<br />

the point to use for column<br />

packing. Order replacements<br />

below.<br />

VIBROGRAVER<br />

DESCRIPTION PART NO. PRICE<br />

Vibrograver<br />

110V 8006<br />

220V 8018<br />

Replacement Point<br />

Diamond 15044<br />

Carbide 15045<br />

5086<br />

6633<br />

5076<br />

389


Gas Flow<br />

A C C E S S O R I E S<br />

Cylinder <strong>Accessories</strong><br />

Cylinder Status Tags<br />

Cylinder status tags help to<br />

organize and positively identify<br />

cylinders.<br />

CYLINDER STATUS TAGS<br />

DESCRIPTION PART NO. PRICE<br />

Cylinder Status Tags, 25/pk 8004<br />

Cylinder Tools<br />

Conveniently open valves, tighten gauges,<br />

connections, regulators, etc.<br />

5250<br />

Flash Arrestors<br />

• Prevent dangerous flashbacks<br />

• Meets OSHA requirements<br />

Flash arrestors shut off gas flow<br />

6099<br />

in the event of a flashback and<br />

extinguish the flame within the housing before it reaches<br />

your gas source. Flash arrestors are available in brass for<br />

general laboratory applications and stainless steel for<br />

high purity applications.<br />

Specifications<br />

PART NO. 37126 PART NO. 37128<br />

Materials of Construction<br />

Body: Brass 316 SS<br />

Seat: Butyl Rubber Viton A<br />

O-rings: Butyl Rubber PTFE-coated Viton<br />

Internal Parts: Brass & Steel SS<br />

Connections:<br />

1/4" FPT<br />

Max Service Pressure: Acetylene and Natural Gas - 15 psig<br />

Oxygen - 150 psig<br />

Propane and Hydrogen - 50 psig<br />

Dimensions:<br />

2" o.d. x 3-1/2"L (without fittings)<br />

Weight:<br />

2 lbs<br />

390<br />

6777<br />

Cylinder Valve & Cap Wrench<br />

© Copyright 2004 Alltech Associates, Inc.<br />

9-way Cylinder Wrench<br />

CYLINDER TOOLS<br />

DESCRIPTION PART NO. PRICE<br />

Tools<br />

Cylinder Valve & Cap Wrench 37135<br />

9-Way Cylinder Wrench 412933<br />

Cylinder Holders<br />

Prevent toppling<br />

of cylinders with<br />

these cast aluminum<br />

cylinder holders.<br />

Holders feature a<br />

nylon web strap with<br />

a sturdy buckle and<br />

are available with an<br />

optional safety chain.<br />

Cylinder holders<br />

wall mount cylinder holder<br />

with safety strap<br />

handle cylinders from 4 to 15 inches in diameter. Choose<br />

from benchtop or wall mount styles.<br />

CYLINDER HOLDERS<br />

DESCRIPTION PART NO. PRICE<br />

Bench Top Model with Cylinder Strap 37132<br />

Bench Top Model with Cylinder Strap and Safety 37214<br />

Chain<br />

Wall Mount Model with Cylinder Strap 37133<br />

Wall Mount Model with Cylinder Strap and Safety 37215<br />

Chain<br />

5178<br />

6098<br />

FLASH ARRESTORS<br />

DESCRIPTION PART NO. PRICE<br />

Brass 37126<br />

316 SS 37128<br />

Matheson Switchover Systems<br />

• Automatically change cylinders<br />

• Compact design minimizes wall<br />

space consumption<br />

Automatically switch from<br />

one cylinder to another without<br />

interruption providing a continuous<br />

6094<br />

supply of gas. Systems also minimize the risk of<br />

ambient contamination within your gas delivery network.<br />

Available in brass or stainless steel and with or without<br />

regulators. Order connecting flex hose separately under<br />

“<strong>Accessories</strong>” below.<br />

MATHESON SWITCHOVER SYSTEMS<br />

DESCRIPTION PART NO. PRICE<br />

Matheson Switchover Systems<br />

Model 5234 Brass 37139<br />

Model 5244 SS 37143<br />

Model 5230 Brass w/Regulator 37138<br />

Model 5240 SS w/Regulator 37141<br />

<strong>Accessories</strong> (Flex Hoses)<br />

3ft. SS with 1/4" NPT Female Connections 37118<br />

3ft. SS with Brass CGA Connections* 37122<br />

3ft. SS with SS CGA Connections* 37124<br />

* Specify CGA number.<br />

For additional information on Matheson<br />

Switchover Systems, request Data Sheet 37138.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Gas Flow<br />

Flow Controllers<br />

Flow Diverter<br />

Easily divert the gas stream from<br />

your detector to your soapfilm<br />

flowmeter. One Flow Diverter<br />

is required for each gas. It is<br />

supplied with 1/8" fittings.<br />

FLOW DIVERTER<br />

DESCRIPTION PART NO. PRICE<br />

Flow Diverter 4200<br />

Adjustable Flow Controller<br />

• Control flow rates from 0.5 mL/min<br />

up to 1.6 L/min<br />

This adjustable flow controller<br />

features a user variable span<br />

adjustment permitting it to be used for<br />

a variety of flow ranges. Use the tenturn<br />

knob to easily adjust flow rates<br />

from zero to maximum. Pipe adapters<br />

for 1/8" o.d. tubing are included.<br />

Specifications:<br />

Flow rate: Adjustable from 1.6mL/min to 0.5L/min<br />

Body:<br />

Aluminum<br />

Diaphragm: Stainless Steel<br />

Max Pressure: 250psig<br />

Max Temp: 120°C<br />

Ports:<br />

1/8" MPT<br />

FLOW CONTROLLER<br />

DESCRIPTION PART NO. PRICE<br />

Adjustable Flow Controller 8149<br />

Eco-Mizer<br />

• Conserve expensive gases during<br />

standby periods<br />

• Decrease laboratory operating expenses<br />

• Directly connects to 1/8" o.d. tubing<br />

The Eco-Mizer is a compact standby<br />

valve designed to conserve gases overnight<br />

and during other non-use periods. The adjustable<br />

fine metering valve sets the standby flow rate and a<br />

concentric, independent valve allows selection of either<br />

standby flow rate or straight-through flow.<br />

ECO-MIZER<br />

DESCRIPTION PART NO. PRICE<br />

Eco-Mizer 7070<br />

© Copyright 2004 Alltech Associates, Inc.<br />

5226<br />

5227<br />

5251<br />

Aalborg Flow Controllers<br />

Tiltable LCD readout<br />

for easy viewing<br />

• Indicate and control<br />

set flow rates of gases<br />

• Compact design won’t<br />

take up valuable bench<br />

space<br />

• NIST traceable<br />

certification<br />

These flow controllers<br />

feature a built-in<br />

electromagnetic valve<br />

4202<br />

that allows the flow to<br />

be set to any desired rate within the flow range. The<br />

valve is normally closed to ensure that gas flow is shut<br />

off in the event of a power outage. Setpoints can be<br />

controlled locally or remotely via the 4-20mA output.<br />

The LCD readout can be tilted over 90° and is easily<br />

removable for remote reading. Flow controllers are<br />

available in aluminum and brass for use with noncorrosive<br />

gases or 316 stainless steel for corrosive<br />

applications. Order power supply separately under<br />

“<strong>Accessories</strong>”.<br />

Specifications:<br />

Accuracy:<br />

+/-1.5% full scale<br />

Repeatability:<br />

+/-0.5% full scale<br />

Max Pressure:<br />

500psig<br />

Ambient Temperature: 5 to 50°C<br />

Output:<br />

0-5 VDC, 4-20mA<br />

Connections:<br />

1/4" compression<br />

Display:<br />

3-1/2 digit LCD<br />

Power:<br />

Order power supply separately<br />

FLOW RATE<br />

FLOW CONTROLLERS*<br />

ALUMINUM BODY<br />

PART NO.<br />

ACCESSORIES<br />

PRICE<br />

SS BODY<br />

PART NO.<br />

0-50mL/min 74428 $775.00 74435<br />

0-100mL/min 74429 775.00 74436<br />

0-200mL/min 74430 775.00 74437<br />

0-500mL/min 74431 775.00 74438<br />

0-1L/min 74432 775.00 74439<br />

*Please specify metered gas, and flow range<br />

PRICE<br />

DESCRIPTION PART NO. PRICE<br />

Flow Controller Power Supplies<br />

110V/12VDC 74487<br />

220V/12VDC European 74488<br />

Shield Cable, 8ft., Unterminated Ends 74492<br />

Battery Pack (Includes Case)<br />

110V 74418<br />

220V 74419<br />

Contact your Alltech office or distributor for current or local prices.<br />

391


Gas Flow<br />

A C C E S S O R I E S<br />

Flowmeters<br />

Soapfilm Flowmeter<br />

Economical flow measurement<br />

This soapfilm flowmeter is easy to use.<br />

Simply time the movement of a soap bubble<br />

be tween two calibration marks. Alltech’s<br />

soapfilm flowmeters have a unique bubble<br />

burster at the top to eliminate the overflow of<br />

the soap solution. A rubber bulb is included<br />

with each soapfilm flowmeter. The 100µL and<br />

500µL flowmeters are complete with stand and<br />

tubing. Order soapfilm solution and tubing under<br />

“<strong>Accessories</strong>” below.<br />

SOAPFILM FLOWMETERS<br />

DESCRIPTION PART NO. PRICE<br />

Flowmeters<br />

100µL 14184<br />

500µL 14185<br />

1cc 4041<br />

10cc 4042<br />

25cc 4043<br />

100cc 4045<br />

1000cc 4047<br />

<strong>Accessories</strong><br />

Soapfilm Solution, 8oz 2040<br />

5/16" o.d. Tygon Tubing, 10ft 4333<br />

Need Help Timing Your Flowmeter?<br />

Lightweight Stopwatch<br />

This stopwatch counts up to 24 hours with<br />

0.01sec readout and has split interval<br />

function, alarm clock with a choice of 12 or<br />

24 hour format, a calendar displaying date<br />

and day of the week, hourly chime option<br />

and button cell battery.<br />

Large Display Stopwatch<br />

This stopwatch features a large, 1/2" LCD<br />

display. It counts with a resolution of<br />

0.01sec and has split interval, clock and<br />

calendar functions. It includes a rugged<br />

ABS plastic clip, neck cord, leatherette<br />

case, stand clip and a 1.5V battery.<br />

5195<br />

Digital Soapfilm<br />

Flowmeter<br />

Patented U-tube design<br />

for lighter than air gases<br />

• NIST traceable calibration<br />

• 2-3% of reading accuracy<br />

• LCD display<br />

• Autoranging<br />

Alltech digital soapfilm<br />

flowmeters provide for easy<br />

gas measurement and allow you to visually<br />

confirm gas flow. Flowmeters feature microprocessor<br />

control and display flow rates, default conditions and<br />

set test results on the LCD. Automatic shut off extends<br />

battery life and manual reset corrects fault conditions.<br />

Part No. 4068 also measures split ratios. Optional<br />

carrying case, tubing and tubing clamps are available<br />

under “<strong>Accessories</strong>” below.<br />

What’s included: 9V battery and operation manual<br />

DIGITAL SOAPFILM FLOWMETERS<br />

DESCRIPTION PART NO. PRICE<br />

Alltech Digital Flowmeter<br />

0.10-50mL/min 4074<br />

0.5-700mL/min 4068<br />

5.0mL- 5.00L/min 4077<br />

<strong>Accessories</strong><br />

Carrying Case 4087<br />

Small Tubing Clamp 4091<br />

Large Tubing Clamp 4093<br />

Gum Rubber Tubing, 3/32" i.d. x 24" 4099<br />

Replacement Parts<br />

Small Bulb 4095<br />

Large Bulb 4097<br />

Recalibration Service<br />

0.10-50mL/min 40740<br />

0.5-500mL/min 406801<br />

5.0mL- 5.00L/min 40770<br />

Visibly Detect Small Leaks in<br />

Any System<br />

Leak Check Solution<br />

5189<br />

STOPWATCHES<br />

DESCRIPTION PART NO. PRICE<br />

Lightweight Stopwatch 4069<br />

Large Display Stopwatch 4071<br />

LEAK CHECK<br />

DESCRIPTION PART NO. PRICE<br />

Leak Check, 8oz. 2025<br />

392<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Gas Flow<br />

Flowmeters<br />

Aalborg Single Tube Variable Area<br />

Flowmeters<br />

Built-in needle valve controls flow<br />

• Magnifier lens enhances reading<br />

resolution<br />

• Ideal for panel mounting<br />

Aalborg single tube flowmeters are<br />

equipped with easy to change flowtubes<br />

and a control valve. Each flowtube is<br />

precision fabricated from heavy wall,<br />

shock resistant borosilicate glass.<br />

Flowtubes are available in 65mm or<br />

150mm sizes. The floats are retained by<br />

TFE plugs. Order a bench stand and fittings separately<br />

under “<strong>Accessories</strong>” below.<br />

Specifications<br />

Accuracy: +/-5% full scale<br />

Repeatability: +/-0.25%<br />

Max Pressure: 200psig<br />

Max Temperature: 121°C<br />

Connections: 1/8" FPT inlet and outlet<br />

5198<br />

Aalborg Three Tube Variable Area Flowmeter<br />

Measure hydrogen, air and carrier gases with one<br />

meter<br />

• Direct reading for hydrogen and air<br />

• Carrier gas tube can be correlated for<br />

any gas<br />

• Can be panel-mounted or free standing<br />

This three tube flowmeter is ideal for<br />

monitoring carrier gas, hydrogen and<br />

5197<br />

air flows used with flame ionization<br />

detectors. A direct reading of hydrogen and air flow<br />

rates can be directly read on the flow tube. The carrier<br />

gas tube features a 0 to 76mm scale, graduated in 1mm<br />

increments. The tubes and flow control valves are easily<br />

disassembled for cleaning.<br />

Specifications<br />

Accuracy: +/-5% full scale<br />

Repeatability: +/-0.25%<br />

Max Pressure: 200psig<br />

Max Temperature: 121°C<br />

Connections: 1/8" FPT inlet and outlet<br />

SINGLE TUBE FLOWMETERS<br />

FLOWTUBE RANGE DIV. PART NO. PRICE<br />

65mm Flowtubes, Direct Reading Scale<br />

Helium 0-120cc/min 5mL 7900<br />

Hydrogen 0-100cc/min 5mL 7902<br />

Nitrogen 0-120cc/min 5mL 7904<br />

Air 0-1.15L/min .05L 7906<br />

General Purpose 0-2L/min (air) 1mm 7908<br />

150mm Flowtubes, Direct Reading Scale<br />

Helium 0-100cc/min 5mL 7910<br />

Hydrogen 0-100cc/min 5mL 7912<br />

Nitrogen 0-100cc/min 5mL 7914<br />

Air 0-1.25L/min .05L 7916<br />

General Purpose 0-2L/min (air) 1mm 7918<br />

<strong>Accessories</strong><br />

Bench Mount for Above Flowmeters 7920<br />

1/8" to 1/8" MPT Brass Connector 60038<br />

1/4" to 1/8" MPT Brass Connector 60042<br />

Need a leak detector?<br />

See page 397 for our<br />

complete selection.<br />

Portable Flow Check<br />

THREE TUBE FLOWMETER<br />

DESCRIPTION PART NO. PRICE<br />

Three Tube Flowmeter 4040<br />

Direct analog reading of gas flows<br />

• Easy-to-read 4-inch scale<br />

• NIST traceable calibration<br />

The Portable Flow Check allows you to directly<br />

measure air, nitrogen, helium and hydrogen flow rates.<br />

Each flowmeter is factory calibrated prior to<br />

shipment. A one-point NBS/NIST traceable calibration<br />

certificate is included with each flowmeter.<br />

Specifications<br />

Flow rate:<br />

He and N2:<br />

0-100mL/min<br />

H2: 0-200mL/min<br />

Air:<br />

0-500mL/min<br />

Max Pressure:<br />

15psig<br />

Accuracy:<br />

+/-5% full scale<br />

Display:<br />

Analog scale<br />

Dimensions:<br />

6-3/4"H x 2-1/2"W x 5-1/4"L<br />

5196<br />

© Copyright 2004 Alltech Associates, Inc.<br />

6711<br />

PORTABLE FLOW CHECK<br />

DESCRIPTION PART NO. PRICE<br />

Portable Flow Check 7080<br />

Contact your Alltech office or distributor for current or local prices.<br />

393


Gas Flow<br />

A C C E S S O R I E S<br />

Flowmeters<br />

Alltech Digital Flow Check Mass Flowmeters<br />

NIST traceable calibration for seven gases<br />

• Measure Air, Helium, Hydrogen, Nitrogen, Oxygen, 5% Argon/Methane and<br />

Carbon Dioxide<br />

• Water vapor will not affect readings—suitable for purge and trap applications<br />

• +/-2% of reading accuracy insures your flow rates are on target<br />

• DFC-HR high resolution model is ideal for low-flow applications<br />

Alltech’s model DFC and DFC-HR Digital Flow Check flowmeters feature<br />

unsurpassed versatility. Both models come standard with NIST traceable calibration<br />

for seven gases making them suitable for <strong>GC</strong> applications such as monitoring<br />

detector gases, packed column flow rates and determining split ratios. Flowmeters<br />

can be used in SFC, SFE, and industrial hygiene applications as well as in the<br />

general lab. Install flowmeters in-line for continuous flow monitoring to traps,<br />

6249<br />

sorbent tubes, incubators, fermentors or reaction vessels without interrupting gas<br />

flow. Use flowmeters with either a positive or negative (vacuum) flow source.<br />

The DFC and DFC-HR mass flowmeters incorporate a rugged solid-state sensor with microprocessor control that<br />

measures true mass flow eliminating the ambient temperature and pressure change errors associated with other types<br />

of flowmeters. Water vapor errors have also been eliminated. Flow measurements will be precise and accurate to<br />

within +/-2% of your reading. Gas flow travels straight through the meter reducing backpressure, internal volume<br />

and sensor purge time allowing for readings to stabilize quickly. Easily change between mass flow, linear velocity and<br />

split ratio modes.<br />

Both Digital Flow Check meters are shipped with an NIST traceable multi-point certificate of calibration<br />

that includes percent error data. Meters are calibrated for seven gases using NIST traceable standards. Periodic<br />

recalibration is recommended to maintain accuracy and compliance with ISO, GLP, GMP and other quality standards.<br />

Model DFC Standard Mass Flowmeter has a measurement range of 0.1 to 300 SCCM for CO2 and 0.1 to 500 SCCM<br />

for the remaining gases. It is lightweight, portable and easy to use. Display resolution of 0.1 SCCM makes it ideal<br />

for most applications.<br />

Model DFC-HR High Resolution Mass Flowmeter features a display resolution of 0.01 SCCM when measuring<br />

below 10 SCCM providing a higher degree of precision required for low-flow applications such as setting capillary <strong>GC</strong><br />

flow or leak testing. Measurement range is 0.01 to 300 SCCM for CO2 and 0.1 to 500 SCCM for the remaining gases.<br />

Use the autozero function to quickly zero the meter for current ambient conditions.<br />

What’s included: Both models include 1 ft of 1/32" (0.8mm) i.d. silicone tubing, 1 ft of 1/8" (3.8mm) i.d.<br />

silicone tubing, 2 barbed inlet/outlet fittings for each tubing size, a general purpose adapter to connect to Agilent<br />

FID, splint vent traps, packed <strong>GC</strong> columns and gas lines, split vent adapter for connection to Agilent <strong>GC</strong> split vents,<br />

and 9V battery. Model DFC-HR also includes a capillary column adapter. Replacement accessories on facing page.<br />

394<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Suggested Flowmeter Applications<br />

Low Flow Applications (DFC-HR )<br />

• Capillary <strong>GC</strong> Flows<br />

• Split Ratios<br />

• Leak Testing<br />

• Applications Requiring Precise Flow<br />

Measurement Below 10cc/min<br />

<strong>GC</strong> Applications (DFC and DFC-HR )<br />

• Detector Gases<br />

• Packed Column Flow<br />

• Split Ratios<br />

• Linear Velocity<br />

Lab Applications (DFC and DFC-HR )<br />

• Set Instrument Operating Parameters<br />

• Industrial Hygiene Applications<br />

• Monitor Flow to Traps, Sorbent Tubes,<br />

Incubators, Fermentors & Reaction Vessels<br />

• SFC and SFE Applications<br />

• In-Line Applications<br />

• Monitor Vacuum & Purging Processes<br />

• Gas Blending<br />

• Gas Sampling<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Gas Flow<br />

<strong>Accessories</strong> included with DFC & DFC-HR <br />

A<br />

B<br />

<strong>Accessories</strong>:<br />

1/16" (1.6mm) Barbed Inlet/Outlet Fitting for DFC-HR <br />

A<br />

Flowmeter (Part No. 5707)<br />

C<br />

F<br />

G<br />

D<br />

E<br />

B<br />

1/8" (3.8mm) Barbed Inlet/Outlet Fitting for DFC-HR <br />

Flowmeter (Part No. 5706)<br />

C Split Vent Adapter (Part No. 4705)<br />

D General Purpose Adapter (Part No. 4704)<br />

E Capillary Column Adapter (Part No. 5705)<br />

F 1/32" (0.8mm) i.d. Connecting Tubing (Part No. 4703)<br />

G 1/8" (3.8mm) i.d. Connecting Tubing (Part No. 4785)<br />

6557<br />

Flowmeter Specifications<br />

Flow range:<br />

Model DFC: 0.1 to 500 SCCM autoranging (except CO2); 0.1 to 300 SCCM autoranging for CO2<br />

Model DFC-HR: 0.01 to 500 SCCM autoranging (except CO2); 0.01 to 300 SCCM autoranging for CO2<br />

Accuracy:<br />

Model DFC: +/-2% of reading or 0.1 SCCM<br />

Model DFC-HR: +/-2% of reading or 0.01 SCCM (for range of 0.01 to 9.99 SCCM),0.1 SCCM (for range of 10 to 500 SCCM)<br />

Calibrated Gases: He, H2, N2, O2, CO2, Air, Ar/CH4 (5%)<br />

Sensor type: Solid-state mass flow, silicon on ceramic<br />

Display:<br />

16-character alphanumeric LCD, autoranging<br />

Display modes: Mass flow, split ratio, linear velocity (standard flow range)<br />

Power:<br />

9V alkaline battery (included), auto-off function, low battery warning<br />

Dimensions: 190.5 x 57.4 x 101.6mm (7.5” x 2.26” x 4.0”)<br />

Keep your flowmeter in check!<br />

When it’s time to recalibrate your<br />

Digital Flow Check , contact Alltech<br />

Customer Service!<br />

DIGITAL FLOW CHECK FLOWMETERS<br />

MODEL PART NO. PRICE<br />

DFC 4700<br />

DFC-HR 5700<br />

Insure your connections are leak free<br />

© Copyright 2004 Alltech Associates, Inc.<br />

See page 397 for Alltech's<br />

Helium Leak Detector<br />

REPLACEMENT ACCESSORIES<br />

DESCRIPTION PART NO. PRICE<br />

1/16" (1.6mm) Barbed Inlet/Outlet Fitting<br />

for DFC-HR , 2/pk<br />

1/8" (3.8mm) Barbed Inlet/Outlet Fitting<br />

for DFC-HR , 2/pk<br />

5707<br />

5706<br />

Split Vent Adapter 4705<br />

General Purpose Adapter 4704<br />

Capillary Column Adapter for DFC-HR 5705<br />

1/32" (0.8mm) i.d. Connecting Tubing, 10' 4703<br />

1/8" (3.8mm) i.d. Connecting Tubing, 1m 4785<br />

Contact your Alltech office or distributor for current or local prices.<br />

395


Gas Flow<br />

A C C E S S O R I E S<br />

Flowmeters<br />

Agilent ADM Digital Flowmeters<br />

Measure any non-corrosive, non-flammable gas<br />

• Continuous, hands-free<br />

flow measurement<br />

• Quickly measure split<br />

ratios<br />

• NIST traceable<br />

calibration<br />

These Agilent ADM<br />

flowmeters are ideal for<br />

6313<br />

basic <strong>GC</strong> analysis. They<br />

accurately measure<br />

volumetric gas flow making them compatible with any<br />

non-corrosive, non-flammable gas. Flowmeters are easy<br />

to use — flow measurements are displayed at the touch<br />

of a button. All meters include five-point calibration<br />

traceable to NIST standards.<br />

ADM-1000 - This basic flowmeter has all of the<br />

features required for basic <strong>GC</strong> analysis—continuous real<br />

time volumetric flow measurements, automatic split ratio<br />

measurements and operates on a 9V battery.<br />

ADM-3000 - This standard flowmeter includes all of<br />

the features of the ADM-1000, as well as RS-232 output<br />

for data logging. Flowmeter operates on AC power or a<br />

9V battery<br />

ADM-2000 - This deluxe flowmeter includes all of<br />

the features of the ADM-3000 plus it measures mass<br />

flow rates independent of atmospheric temperature and<br />

pressure.<br />

Specifications<br />

Accuracy: +/-3%<br />

Display:<br />

16-character alphanumeric<br />

AGILENT ADM DIGITAL FLOWMETERS<br />

MODEL DESCRIPTION FLOW RATE RS-232 OUTPUT POWER PART NO. PRICE<br />

ADM 1000 Basic 0.5-1000 mL/min No 9V battery 9965<br />

ADM 3000 Standard 1.0-750 mL/min Yes 9V battery or AC 6365<br />

ADM 2000 Deluxe 0.5-1000 mL/min Yes 9V battery or AC 7065<br />

Aalborg Mass Flowmeters<br />

Handle pressures up to 500psig<br />

• Tiltable LCD readout for<br />

easy viewing<br />

• Flow rates displayed in<br />

engineering units<br />

• NIST traceable<br />

certification<br />

2595<br />

Specifications<br />

Accuracy<br />

+/-1.5% full scale<br />

Repeatability +/-0.5%<br />

Max Pressure<br />

500psig<br />

Max Temperature 50°C<br />

Display<br />

3-1/2 digit LCD<br />

Output<br />

0-5 VDC or 4-20mA<br />

Connections<br />

1/4" compression fittings<br />

AALBORG FLOWMETERS*<br />

These compact mass flowmeters are designed to<br />

directly read flow rates of gases. Meters feature a<br />

display module that is tiltable over 90 degrees and can<br />

be easily removed for remote reading. Flowmeters are<br />

available in aluminum or stainless steel and can be used<br />

on the benchtop or wall-mounted. Order power supply<br />

separately under “<strong>Accessories</strong>”.<br />

FLOW RATE<br />

ALUMINUM BODY<br />

PART NO.<br />

PRICE<br />

SS BODY<br />

PART NO.<br />

0-50 mL/min 74400 74401<br />

0-100 mL/min 74402 74403<br />

0-200 mL/min 74404 74405<br />

0-500 mL/min 74406 74407<br />

0-1 L/min 74422 74425<br />

<strong>Accessories</strong> (Power Supplies)<br />

110V/12VDC 7447<br />

220V/12VDC European 7449<br />

*specify type of gas and pressure range when ordering<br />

PRICE<br />

396<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Gas Flow<br />

Gas Leak Detection<br />

Alltech Helium Leak Detector<br />

Designed specifically to detect helium gas leaks<br />

• Portable—operates up to 6.5 hours fully charged<br />

• Visual and audible detection<br />

indicators<br />

• Change polarity setting to<br />

detect other gases<br />

The Alltech helium leak detector is perfect for<br />

detecting gas leaks in <strong>GC</strong>, <strong>GC</strong>/MS, and purge/trap<br />

systems. Leaks are detected via a thermal conductivity<br />

cell and indicated visually on the LCD display and by<br />

an audible alarm. The long flexible probe makes it<br />

convenient to detect small and hard to reach gas leaks.<br />

Use the detector for gases other than helium by simply<br />

changing the polarity setting. Detector features a<br />

simple one-step zero adjustment and is fully portable<br />

operating on rechargeable Ni-Cd batteries.<br />

What’s included: probe, rechargeable batteries and<br />

charger<br />

Helium Leak Detector<br />

Detector: Thermal conductivity cell with thermistors<br />

Sensitivity: 0.01 mL/min for Helium<br />

Ambient Temp: 10 to 35°C<br />

Display: LCD indicator lights<br />

Zero Function: Yes<br />

Audible Signal: Yes<br />

Battery Life: 6.5 hours continuous fully charged<br />

Dimensions: 2.9"W x 1.6"H x 6.3"L<br />

(7.366cmW x 4.064cmH x 16.002cmL)<br />

Weight:<br />

1 lb (.454 kg)<br />

Note: The Alltech helium leak detector is not explosion-proof and should not<br />

be used to detect combustible or corrosive gas leaks<br />

HELIUM LEAK DETECTOR<br />

POWER DESCRIPTION PART NO. PRICE<br />

120 VAC charger w/rechargeable Ni-Cd batteries 60229<br />

220 VAC charger w/rechargeable Ni-Cd batteries 60231<br />

6711<br />

6428<br />

Gow-Mac ® Gas Leak Detectors<br />

Control meter sensitivity — ideal for detecting<br />

small leaks<br />

• Zero in ambient air<br />

• Detect helium leaks as small as<br />

1.0 x 10-5mL/sec<br />

These gas leak detectors easily<br />

and quickly pinpoint gas leaks<br />

5239<br />

emitting from pressurized systems.<br />

The detectors conveniently zero in ambient air and<br />

feature a streamlined probe that is designed to reach<br />

difficult and confined spaces.<br />

The portable model is light weight and features an<br />

LED bar graph visual readout and automatic zeroing. The<br />

benchtop model has an audible signal in addition to the<br />

analog graduated scale.<br />

What’s included: probe with 3ft cable, rechargeable<br />

batteries and power adapter.<br />

Specifications<br />

PORTABLE<br />

BENCHTOP<br />

Detector:<br />

Thermal conductivity cell with thermistors<br />

Range:<br />

Low: x1 High: x100<br />

Sensitivity:<br />

1.0 x 10-5 mL/sec for helium<br />

Display: LED bar graph Graduated analog scale<br />

Zero Function: Automatic Manual<br />

Audible Signal: None Yes<br />

Battery Life: 3.5 hours 4 hours<br />

Dimensions: 3-1/4"W x 1-13/16"H x<br />

5-1/4"L<br />

(8.255cmW x 2.064cmH<br />

x 13.335cmL)<br />

8-1/4"W x 3-5/8"H x<br />

10-3/4"L<br />

(20.955cmW x 9.206cmH<br />

x 27.305cmL)<br />

Weight: 2 lbs (.9072 kg) 9 lbs (4.082 kg)<br />

GAS LEAK DETECTORS<br />

DESCRIPTION PART NO. PRICE<br />

Portable<br />

115VAC/60Hz or rechargeable Ni-Cd batteries 21-050<br />

230VAC/50Hz or rechargeable Ni-Cd batteries 21-052<br />

Benchtop<br />

115VAC/60Hz or rechargeable battery pack 21-250<br />

230VAC/50Hz or rechargeable battery pack 21-252<br />

<strong>Accessories</strong><br />

Carrying case for portable gas leak detectors 59-050<br />

Leak-Tec ® High Temp Testing Solution<br />

Temperature range is 210 to 415°F<br />

This testing solution wets and spreads evenly<br />

and quickly responding to small leaks. Leak-Tec ® is<br />

non-corrosive and residue free. Convenient aerosol<br />

can allows spray to be directed in tight spaces.<br />

5241<br />

Leak-Check Testing Solution<br />

Leak-Check is non-toxic, non-flammable,<br />

chloride-free and dries cleanly leaving no residue<br />

behind. Temperature range is 30 to 200°F.<br />

Bottle includes a 15" snorkel tube allowing for<br />

easy access to hard-to-reach spaces.<br />

5242<br />

LEAK-TEC ®<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Leak-Tec ® , 10oz ea 2027<br />

6 2028<br />

© Copyright 2004 Alltech Associates, Inc.<br />

LEAK-CHECK <br />

POWER DESCRIPTION QTY. PART NO. PRICE<br />

Leak-Check , 8oz ea 2025<br />

12 2026<br />

Contact your Alltech office or distributor for current or local prices.<br />

397


Purifiers<br />

A C C E S S O R I E S<br />

Gas Purifiers and Traps<br />

Why Use Gas Purifiers?<br />

A clean gas stream helps guarantee the quality of<br />

your <strong>GC</strong> analysis and the reliability of your results. It<br />

also helps prolong column life and minimize detector<br />

noise. Gas purifiers act as an insurance policy, protecting<br />

your instrumentation and analytical columns from these<br />

contaminants. They will not however, convert low purity<br />

gas into ultra high purity gas. Alltech carries a variety<br />

of gas purifiers in three different styles. See Table 1 for<br />

details.<br />

5333 5334 5335<br />

Baseplate Style Cartridge Style In-Line Style<br />

Table 1 - Gas Purifier Styles<br />

STYLE BASEPLATE CARTRIDGE IN-LINE<br />

Placement:<br />

Stands on<br />

Benchtop<br />

Stands on<br />

Benchtop<br />

Freely supported on<br />

gas lines<br />

Repeat Use: Refill* Replace Cartridge Refill*<br />

Benefit: Convenient<br />

access, no<br />

mounting<br />

required<br />

Convenient access,<br />

stops gas flow<br />

when changing<br />

cartridges<br />

Occupies wall space<br />

not bench space<br />

*Refills for most materials are available. See specific gas purifiers for refill kit<br />

part numbers.<br />

Choosing the Right Gas Purifier for Your<br />

Application<br />

There are a variety of gas purifiers available.<br />

Some remove a specific contaminant while others<br />

remove multiple contaminants from your gas stream.<br />

There are several factors you need to consider when<br />

selecting purifiers for your application. These include<br />

contaminants potentially present in your gas stream,<br />

gas purity levels required, flow and pressure limitations,<br />

space availability, and desired convenience when<br />

replacing spent traps.<br />

Moisture, hydrocarbon, and oxygen traps are the most<br />

commonly used purifiers for <strong>GC</strong> applications. Moisture<br />

traps are typically packed with molecular sieves. After<br />

extensive heating, these crystalline structures lose their<br />

water of hydration opening a cavity that is readily filled<br />

with any compound that can fit. Water fits perfectly.<br />

However, it will also remove HCl, CO2, SO2, Cl2, or any gas<br />

with an effective diameter smaller than water.<br />

Hydrocarbon traps are packed with an activated<br />

charcoal that adsorbs any organic compound larger<br />

than methane. Size and molecular weight of the<br />

organic contaminants will greatly effect the capacity<br />

of the trap, and to a smaller degree, trap efficiency.<br />

Activated charcoal has a higher capacity for larger (>C4)<br />

hydrocarbons than for smaller hydrocarbons.<br />

Oxygen traps are packed with a metal catalyst.<br />

Oxygen is the most detrimental contaminant to<br />

analytical columns. It produces irreversible oxidation<br />

damage particularly to polar stationary phases. Refer to<br />

Table 2 for a recommendation of what purifiers to use<br />

for various <strong>GC</strong> applications.<br />

398<br />

How Contaminants Affect Your Gas Stream<br />

Follow the path that your carrier gas or detector fuel<br />

gases take to get to the <strong>GC</strong>. They start at either a gas<br />

tank or a gas generator, and travel through long lengths<br />

of tubing, pressure gauges, various fittings, and valves.<br />

Each is a potential culprit for introducing contaminants<br />

into your gas stream, which ultimately degrades<br />

chromatography results and shortens column life.<br />

Typical contaminants, such as moisture, oxygen,<br />

and hydrocarbons wreak havoc with <strong>GC</strong> columns and<br />

detectors. Capillary and packed columns can degrade<br />

when exposed to moisture or oxygen, particularly at<br />

high temperatures. Detector performance may also be<br />

compromised. Since the detector can actually “see” the<br />

contaminants, spikes, baseline noise, and drift result.<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Table 2 - Gas Purifier Recommendations<br />

SYSTEM DETECTOR GAS STREAM RECOMMENDED PURIFIER<br />

Packed Column <strong>GC</strong><br />

All Carrier Gas Hydrocarbon, Moisture,<br />

Oxygen, and Indicating<br />

Oxygen<br />

Capillary Column <strong>GC</strong><br />

All Carrier Gas Hydrocarbon, Moisture,<br />

Oxygen, and Indicating<br />

Oxygen<br />

ECD Make-Up Moisture and Oxygen<br />

FID Make-Up Hydrocarbon<br />

FID Air for FID Hydrocarbon<br />

FID Hydrogen for FID Hydrocarbon<br />

ELCD ELCD Reaction Gas Hydrocarbon<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Purifiers<br />

Physical Characteristics<br />

You will also need to consider what physical<br />

characteristics your purifier should possess to meet your<br />

application requirements. Do you require 1/8" or 1/4"<br />

fittings, or are you performing bulk gas purification<br />

that requires 1/2" fittings? What are the pressure<br />

requirements of your application? This will determine if<br />

you need a purifier with a polycarbonate, glass, or metal<br />

body. Where will you be installing the purifier and is<br />

your installation space limited? This will determine the<br />

dimension and style of purifier you should choose.<br />

Purifier Styles<br />

Alltech offers three purifier styles – in-line, baseplate,<br />

and cartridge. The in-line style is the traditional style<br />

that is most commonly used. It can be directly installed<br />

into your gas lines with no support depending on its<br />

dimension or can be easily mounted on the wall with<br />

mounting clips. In-line purifiers must be removed from<br />

the gas line to be refilled or regenerated. We recommend<br />

installing them with quick-connect connectors and<br />

keeping an extra purifier on hand.<br />

The baseplate and cartridge purifiers sit on the<br />

countertop making them easy to access when it is time<br />

to replace spent traps. Both styles can be installed in<br />

series with shut off valves allowing you to easily isolate<br />

them from your gas lines when it is time to replace<br />

them. Baseplate units allow you to easily refill the<br />

purifier with new adsorbent material. Cartridge purifiers<br />

allow you to quickly remove the spent purifier from your<br />

gas line and replace it with a new one.<br />

Purifier Capacity<br />

Purifier capacity indicates the amount of contaminant<br />

a trap is capable of removing before it reaches its point<br />

of saturation. It is dependent on both the adsorbent’s<br />

capabilities and purifier’s volume. You need to consider<br />

the amount of impurities in your gas stream and the<br />

volume of gas you need to purify. If you are purifying a<br />

large volume of gas or a less pure gas, you should select<br />

a high capacity trap with a large volume adsorbent bed<br />

that will trap and retain more contaminants.<br />

Purifier Efficiency<br />

Purifier efficiency is the most important purifier<br />

characteristic. It indicates how effective the adsorbent<br />

is at removing the desired contaminant from your gas<br />

stream. If your application requires high purity levels<br />

or the lowest detection limits, select a purifier that is<br />

packed with a highly efficient adsorbent material that<br />

removes contaminants to ppb levels.<br />

<br />

<br />

Figure 1 — How to Set Up Carrier Gas Purifiers<br />

1. High Capacity or Indicating Moisture Trap<br />

2. High Capacity or Indicating Hydrocarbon Trap<br />

<br />

<br />

<br />

<br />

<br />

<br />

Gas Purifier Installation Order<br />

The order in which you install purifiers into your gas<br />

lines is very important. Figure 1 demonstrates the<br />

correct order for installing purifiers into your carrier<br />

gas line. The moisture trap should be placed first in<br />

line. Both hydrocarbon and oxygen traps will adsorb<br />

water. Installing a moisture trap before these traps<br />

prevents them from becoming prematurely saturated with<br />

moisture. It also allows them to more effectively remove<br />

their specified contaminants from the gas stream. The<br />

hydrocarbon trap should be placed after the moisture<br />

trap. A high capacity oxygen trap and an indicating<br />

oxygen trap should be placed closest to the <strong>GC</strong>. We<br />

recommend installing the series of purifiers as close to<br />

the <strong>GC</strong> as possible.<br />

Gas purifiers should be installed in a vertical position<br />

to prevent channeling. Channeling is a phenomenon<br />

that occurs when a purifier is installed in a horizontal<br />

position. The adsorbent bed settles and the gas stream<br />

passes over the top of the bed rather than through the<br />

bed. The gas stream does not sufficiently interact with<br />

the adsorbent bed to effectively remove impurities.<br />

Gas purification systems simplify purifier installation<br />

in to your gas lines. Systems are available as multiadsorbent<br />

single purifiers or compact panels that contain<br />

multiple purifiers.<br />

Purifier Replacement/Regeneration<br />

3. Oxygen Trap (high<br />

capacity)<br />

4. Indicating Oxygen<br />

Trap<br />

You need to replace your gas purifiers before they<br />

are fully saturated. You can either change them at a<br />

predetermined time interval or use an indicating trap<br />

that changes color as it becomes saturated. There<br />

are potential problems with scheduled replacements.<br />

Undetected leaks or accidental exposure to air during<br />

cylinder changes can prematurely saturate gas purifiers.<br />

Early breakthrough means your column and detectors are<br />

exposed to a constant stream of damaging contaminants.<br />

An indicating trap located downstream from a high<br />

capacity trap is the best way to determine when it’s<br />

time to replace a spent trap. Some purifiers contain<br />

both the high capacity and indicating adsorbent in the<br />

same purifier body while others rely on a separate trap<br />

that serves solely as an indicator. Either way, purifier<br />

replacement should coincide with the first signs of color<br />

change in the indicating adsorbent.<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

4138<br />

399


Purifiers<br />

A C C E S S O R I E S<br />

Alltech Moisture Traps<br />

Remove moisture from your gas system<br />

• Eliminate stationary phase degradation<br />

• Increase column life<br />

• Improve the quality of your chromatography<br />

Remove moisture from gas cylinders, regulators and<br />

gas lines with an Alltech moisture trap. In addition<br />

to H2O, most traps (except the ALL-Pure and Sodium<br />

Sulfate) also remove HCl, SO2, NO2, H2S, CO2, oil, and<br />

small aliphatics. Both indicating and non-indicating<br />

traps are available. Many traps can be regenerated and<br />

are refillable—order refill kits separately.<br />

Alltech offers a wide variety of moisture traps to<br />

meet all of your gas purifying needs. Choose from three<br />

different styles.<br />

Cartridge & Baseplate Style<br />

Moisture Traps<br />

A) Baseplate Style Moisture Traps<br />

- Convenient access for refilling/changing<br />

- sits on the benchtop - requires no<br />

mounting<br />

4659<br />

B) Cartridge Style Moisture Traps<br />

- Simply replace the cartridge when spent<br />

- Gas flow stops while cartridge is changed<br />

- Order baseplate unit separately below<br />

4660<br />

CARTRIDGE AND BASEPLATE MOISTURE TRAPS<br />

CAPACITY<br />

PRESSURE<br />

LIMIT<br />

DIMENSIONS<br />

(L X O.D.) INDICATOR PART NO. PRICE<br />

REFILL KIT<br />

PART NO.<br />

PHOTO CARTRIDGE DESCRIPTION (ML) EFFICIENCY<br />

FITTING<br />

Cartridge & Baseplate Style Traps<br />

1/8"<br />

8122 8132<br />

12<br />

12.5" x 1.5"<br />

1/4" 8126 8132<br />

A Baseplate Moisture Trap<br />


A C C E S S O R I E S<br />

Purifiers<br />

G) Glass Moisture Trap<br />

- Best for carrier gas lines<br />

- Glass housing eliminates diffusion<br />

- 40µm SS frits in endfittings prevent particulates from<br />

entering gas stream<br />

H) ALL-Pure Moisture Trap<br />

- Removes moisture down to


Purifiers<br />

A C C E S S O R I E S<br />

Alltech Oxygen Traps<br />

Protect columns from oxygen contamination<br />

Prevent oxidation of column stationary phases with<br />

Alltech oxygen traps. Use an oxygen trap to help<br />

maintain column performance and prolong column<br />

life. Traps are available in cartridge and in-line styles.<br />

Choose an indicating trap to easily identify when trap<br />

is spent or to use in conjunction with larger capacity<br />

traps. Some traps can be regenerated—see table on<br />

following page.<br />

4828<br />

Cartridge Style Oxygen Traps<br />

A) AT -Indicating Oxy Cartridge<br />

- features the OXY-MAX adsorbent<br />

- Easy to replace - simply change cartridge<br />

- Gas flow stops while cartridge is charged<br />

- Order baseplate separately below<br />

Alltech’s OXY-MAX is<br />

the most efficient oxygen<br />

adsorbent available.<br />

Traps containing OXY-MAX remove 02 to<br />

less than 1ppb.<br />

4829<br />

B) AT -Omni Cartridge<br />

- features the OXY-MAX adsorbent<br />

- Also removes moisture and hydrocarbons<br />

- Easy to replace - simply change<br />

cartridge<br />

- Gas flow stops while cartridge is charged<br />

- Order baseplate separately below<br />

CARTRIDGE OXYGEN TRAPS<br />

PHOTO DESCRIPTION CAPACITY(ML) EFFICIENCY PRESSURE LIMIT DIMENSIONS (L X O.D.) INDICATOR PART NO. PRICE<br />

Cartridge Style Traps<br />

A AT -Indicating Oxy 104


A C C E S S O R I E S<br />

Purifiers<br />

G) Oxy-Purge ® N<br />

- Also removes moisture<br />

- Rugged aluminum housing<br />

- 40µm SS frits in endfittings prevent particulates<br />

from entering gas stream<br />

H) ALL-Pure Oxygen Trap<br />

- Also removes moisture<br />

- Capacity of 1030mL of oxygen<br />

4835<br />

4832<br />

I) Oxi-Clear ® Oxygen Trap<br />

- Removes oxygen, moisture, and hydrocarbons<br />

J) BIG Oxygen Trap<br />

- Our highest capacity trap—3000mL<br />

4839<br />

4831<br />

K) High Pressure Oxy-Trap <br />

- Features OXY-MAX adsorbent<br />

- Handles pressures up to 1800psig<br />

L) Low Pressure Oxisorb ®<br />

- Also removes moisture<br />

4830<br />

4837<br />

PHOTO<br />

DESCRIPTION<br />

CAPACITY<br />

(ML)<br />

EFFICIENCY<br />

IN-LINE OXYGEN TRAPS<br />

PRESSURE<br />

LIMIT<br />

FITTING<br />

DIMENSIONS<br />

(L X O.D.) INDICATOR PART NO. PRICE<br />

REGENERATION<br />

SERVICE<br />

PART NO.<br />

In-Line Style Traps<br />

C Oxy-Trap 133


Purifiers<br />

A C C E S S O R I E S<br />

Alltech Hydrocarbon, CO2, and Sulfur Traps<br />

Eliminate detector noise and increase<br />

baseline stability<br />

• Choose baseplate, cartridge, or in-line styles<br />

• Indicating hydrocarbon trap available<br />

Alltech hydrocarbon traps adsorb trace amounts of<br />

hydrocarbons and organics from your gas stream. Most<br />

traps are packed with activated charcoal and adsorb<br />

organic compounds larger than methane. Traps are<br />

available in a baseplate style that sits on the benchtop,<br />

a cartridge style that allows for easy replacement of the<br />

trap (requires baseplate unit to be ordered separately),<br />

and an in-line style that is freely supported on gas lines.<br />

Traps for CO2, and sulfur are also available.<br />

Baseplate Style Traps<br />

Cartridge Style Traps<br />

6463<br />

C) AT -Indicating Hydrocarbon Trap<br />

- The only indicating trap available for<br />

hydrocarbons<br />

- Changes from bright yellow to dark green<br />

when spent<br />

- Reduce costs by changing trap only when<br />

needed<br />

- Adsorbs organics larger than C2 down to<br />


A C C E S S O R I E S<br />

Purifiers<br />

In-Line Style Traps<br />

F) AT -Indicating Hydrocarbon Trap<br />

- Same features as cartridge format now available in<br />

the in-line style<br />

G) Activated Charcoal Trap<br />

- Two sizes available<br />

6579<br />

4843<br />

H) Hydrocarbon Trap<br />

- Economical<br />

- 250psig pressure rating<br />

I) Hi-EFF ® Organic Trap<br />

- Removes hydrocarbons and moisture<br />

- Indicating for moisture<br />

4848<br />

4843<br />

J) BIG Hydrocarbon Trap<br />

- Large 750cc size<br />

- Helium purged prior to shipment<br />

K) ALL-Pure Hydrocarbon Trap<br />

- Removes hydrocarbons to


Purifiers<br />

A C C E S S O R I E S<br />

Alltech Gas Purification<br />

Cartridge Systems<br />

• Replace spent purifiers without shutting down your<br />

system<br />

Alltech gas purification cartridges allow replacement<br />

of spent cartridges in seconds without shutting down<br />

your <strong>GC</strong> system. Simply pull the spent cartridge off the<br />

baseplate and<br />

push a new one<br />

into place. A<br />

knurled locking<br />

ring keeps<br />

the cartridge<br />

locked in place.<br />

Four different<br />

purification<br />

cartridges<br />

are available.<br />

Knurled<br />

locking ring<br />

Convenient cartridge baseplate<br />

automatically stops gas flow<br />

when changing cartridges<br />

Multiple cartridges and baseplates can be plumbed<br />

together to customize a gas purification system for your<br />

application. Order each cartridge separately below.<br />

Moisture Trap Cartridge - Filled with indicating<br />

Drierite ® and molecular sieve pellets to maximize<br />

moisture removal and to indicate when the cartridge<br />

requires refilling or replacement. A refill kit is available<br />

below.<br />

Organic Trap Cartridge - Removes non-methane<br />

hydrocarbons from your gas stream. A refill kit is<br />

available below.<br />

AT -Omni Cartridge - A multi-purpose cartridge<br />

filled with OXY-MAX and Hi-EFF ® Charcoal to effectively<br />

remove oxygen, moisture and hydrocarbons. AT -Omni<br />

cartridges are disposable.<br />

AT -Indicating Oxy Cartridge - Filled with OXY-MAX <br />

and indicating oxygen adsorbent to efficiently remove<br />

oxygen and small amounts of moisture. The indicating<br />

material shows a color change when the cartridge is<br />

saturated. AT -Indicating Oxy cartridges are disposable.<br />

GAS PURIFICATION CARTRIDGE SYSTEMS*<br />

ALL-Pure Gas Purifiers<br />

• One purifier removes multiple contaminants<br />

• Reduce impurities to low ppb levels<br />

ALL-Pure Gas Purifiers feature a unique proprietary<br />

broad spectrum adsorbent material that removes multiple<br />

contaminants with a single purifier. Replace three<br />

separate purifiers for oxygen, moisture, and hydrocarbons<br />

with a single ALL-Pure purifier. Purifiers are gas specific<br />

or choose purifiers specific for moisture, hydrocarbons or<br />

oxygen.<br />

ALL-Pure Specifications<br />

Dimensions: 400cc, 21"L x 1.5"o.d. (50.8cm x 3.8cm)<br />

Max Flow: 500mL/min<br />

Max. Pressure: 1000psig<br />

Max. Temp: 80°C<br />

Mounting: Purifier must be mounted in vertical position<br />

Purifier Selectivity and Purity Specifications<br />

ALL-PURE GAS PURIFIERS<br />

SULFUR<br />

COMPOUNDS<br />

4851<br />

NON-METHANE<br />

HYDROCARBONS<br />

PURIFIER CO CO2 O2 H2O<br />

Helium Purifier


A C C E S S O R I E S<br />

Purifiers<br />

AT -Multi-Purge II ®<br />

• Three traps conveniently mounted in one panel<br />

• Removes water, oxygen, and hydrocarbons<br />

• Easy wall mounting<br />

The AT -Multi Purge II ® is a high capacity, three<br />

stage gas purifying module that removes all common<br />

contaminates – moisture, hydrocarbons, and oxygen<br />

– from <strong>GC</strong> gas streams. It combines three high capacity<br />

traps (Hydro-Purge II ® , Hydrocarbon, and Oxy-Purge ® N)<br />

to permit longer, maintenance-free operation.<br />

The first stage of gas purification removes moisture<br />

from the gas stream with the Alltech Hydro-Purge II ® .<br />

It contains indicating molecular sieve that changes<br />

from blue to tan when saturated. Stage two removes<br />

hydrocarbon contamination from the gas stream<br />

with the Alltech Hydrocarbon trap. The final stage of<br />

purification removes oxygen from the gas stream with<br />

the Oxy-Purge ® N oxygen trap.<br />

An indicating Oxy-Trap can be added to the AT -<br />

Multi-Purge II ® for maximum column protection. It will<br />

monitor the performance of the oxygen trap and undergo<br />

a color change from tan to dark brown when spent<br />

indicating when the high capacity Oxy-Purge ® N requires<br />

replacement. Order separately under “<strong>Accessories</strong>” below.<br />

Each AT -Multi-Purge II ® is supplied with all internal<br />

plumbing and installation and operating instructions.<br />

AT -MULTI-PURGE II<br />

DESCRIPTION PART NO. PRICE<br />

AT -Multi-Purge II ®<br />

with 1/8" Fittings 14565<br />

with 1/4" Fittings 14564<br />

Replacement Parts<br />

Refill Kit for Hydro-Purge II ® 14637<br />

1/8" Hydrocarbon Trap 14634<br />

1/4" Hydrocarbon Trap 14633<br />

1/8" Oxy-Purge ® N 14636<br />

1/4" Oxy-Purge ® N 14635<br />

ACCESSORIES<br />

DESCRIPTION PART NO. PRICE<br />

1/4" Indicating Oxygen Trap* 4004<br />

* 1/8" reducing ferrules are supplied.<br />

© Copyright 2004 Alltech Associates, Inc.<br />

4853<br />

Gas Control/Purification<br />

Panels<br />

• Complete gas control and<br />

purification station<br />

• Operating pressures up to<br />

100psig<br />

• Allows safer remote<br />

placement of cylinders<br />

Alltech’s gas panels<br />

provide convenient control<br />

and purification of laboratory<br />

gases. The panels are<br />

supplied with valves, gauges,<br />

regulators, purifiers, and<br />

fittings that make installing<br />

Type A<br />

6250 6251<br />

Type B<br />

and maintaining gas purifiers easier. Their wall mount<br />

design conserves bench top space and allows you to<br />

easily view the status of your gas system. Panels can be<br />

used as individual stations or grouped together to form<br />

a gas control center for the entire lab. Each panel is<br />

ready to connect to 1/4" o.d. gas lines. Vespel ® reducing<br />

ferrules allow connection to 1/8" lines.<br />

Two types of panels are available. Type “A” includes<br />

an Alltech Gas Purifier that removes moisture, oil, small<br />

aliphatics, HCl, SO2, NO2, H2S, and CO2, and it measures<br />

29" x 4-5/8" x 3" . Type “B” includes an Alltech Gas<br />

Purifier and an Alltech Indicating Oxy-Trap that also<br />

removes oxygen in addition to the other contaminants,<br />

and measures 29" x 5-5/8" x 3". Both traps contain<br />

indicating adsorbents that allow you to visually<br />

determine when they require replacement.<br />

GAS<br />

GAS CONTROL/PURIFICATION PANELS<br />

TYPE A<br />

PART NO.<br />

PRICE<br />

REPLACEMENT PARTS<br />

TYPE B<br />

PART NO.<br />

Hydrogen 8150 8162<br />

Air 8152 —<br />

Oxygen 8154 —<br />

Helium 8156 8164<br />

Nitrogen 8158 8166<br />

Argon 8160 8168<br />

PRICE<br />

DESCRIPTION PART NO. PRICE<br />

In-Line Gas Purifier, 1/4" 8125<br />

Indicating Oxy-Trap 4004<br />

Regeneration Service for 4004 4014<br />

Refill Kit for 8125 8132<br />

Contact your Alltech office or distributor for current or local prices.<br />

407


Purifiers<br />

A C C E S S O R I E S<br />

SGT Super-Clean ® Filters<br />

Improve baselines, minimize interferences, and reduce MS<br />

maintenance<br />

• Remove impurities to deliver 99.9999% pure gas<br />

• Exchange filters in seconds, without introducing air into the system<br />

• Diffusion-proof with glass and metal construction<br />

• Pressure resistant up to 150psig (11 bar)<br />

These SGT Super-Clean ® filters can be used on all of your <strong>GC</strong> gas lines to deliver<br />

99.9999% pure gas. Filters are available for oxygen, moisture and hydrocarbons.<br />

The Combi filter removes both moisture and hydrocarbons. The Triple filter removes<br />

moisture, oxygen, and hydrocarbons and is available purged with Argon for standard<br />

applications or purged with Helium for MS applications.<br />

Filters feature a quick change baseplate/cartridge design. Cartridges can be<br />

exchanged within seconds, during analysis, and without tools. 1-,2-,3-, or 4-<br />

position baseplates are available and will accept any of the <strong>GC</strong> filter cartridges.<br />

Baseplates must be ordered separately (except for systems). Filter cartridge bundles<br />

include the most popular filters in one package. Various filter systems are available<br />

and include the appropriate baseplate.<br />

Not sure which filter you need?<br />

Contact Alltech Tech Support:<br />

Email: tech_service@alltechemail.com<br />

Online: www.alltechWEB.com<br />

Triple Filter F0301<br />

shown on baseplate<br />

(order separately).<br />

6516<br />

Capacities<br />

Specifications<br />

Maximum Flow:<br />

Efficiency:<br />

Maximum Pressure:<br />

Connectors:<br />

7.0L/min<br />


A C C E S S O R I E S<br />

Purifiers<br />

Purifier <strong>Accessories</strong><br />

Universal Mounting Panel<br />

• Mount up to 5 purifiers for easy monitoring and<br />

replacement<br />

• Pre-drilled for easy mounting<br />

• Fits most manufacturers’ purifiers<br />

This lightweight aluminum mounting panel will hold<br />

up to five purifiers. Pre-drilled holes are spaced at<br />

3⁄4" centers in five vertical rows to allow for maximum<br />

versatility. Mounting clips to accommodate purifiers<br />

from 7/8" to 2-1/2" o.d. are sold separately below.<br />

Panel measures 17"W x 24"H.<br />

In-Line Particulate Filter<br />

• Economically remove particulates from gas streams<br />

This brass in-line particulate filter is a convenient,<br />

inexpensive way to remove particulates from critical<br />

gas streams. Each unit includes one 10 micron filter<br />

cartridge. The maximum pressure rating is 500psig.<br />

4858<br />

IN-LINE PARTICULATE FILTERS<br />

DESCRIPTION PART NO. PRICE<br />

1/4" In-line Brass Filter 8052<br />

1/8" In-line Brass Filter 8054<br />

AT -Purifier Shield for In-Line Traps<br />

• Protect AT purifiers from damage<br />

This shield is compatible with the Alltech In-Line<br />

acrylic purifiers. The AT-Purifier Shield slips over your<br />

existing Alltech purifier, protecting the cartridge while<br />

still allowing visual monitoring of the contents of the<br />

trap.<br />

4854<br />

UNIVERSAL MOUNTING PANEL<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Universal Mounting Panel ea 7220<br />

Universal Mounting Clips<br />

Fits 7/8" to 1" o.d. Traps 2/pk 7221<br />

Fits 1-1/8" to 1-3/8" o.d. Traps 2/pk 7223<br />

Fits 1-3/8" to 1-5/8" o.d. Traps 2/pk 7225<br />

Fits 1-5/8" to 1-7/8" o.d. Traps 2/pk 7227<br />

Fits 2" to 2-1/2" o.d. Traps 2/pk 7229<br />

AT CARTRIDGE SHIELD<br />

DESCRIPTION PART NO. PRICE<br />

Shield for 120cc Purifier 81210<br />

4859<br />

Leaking?<br />

Ensure leak-free installation of<br />

your gas purifiers. See page<br />

397 for gas leak detectors.<br />

Make quick purifier connections!<br />

See page 421 for Quick-Connect Fittings.<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

409


Pressure Regulators<br />

A C C E S S O R I E S<br />

Alltech Regulators<br />

A) Dual Stage Economy<br />

Regulators<br />

These regulators are suitable for<br />

pressure control of general purpose<br />

laboratory gases with applications requiring constant<br />

pressure control and delivery regardless of supply<br />

pressure variations. Typical applications include<br />

purging, pressure testing, blanketing, and chamber<br />

pressurization.<br />

5244<br />

C) Single Stage Regulators<br />

These regulators are suitable for secondary<br />

pressure control of noncorrosive, high purity<br />

gases or as point of use pressure control in<br />

high purity gas distribution systems. Typical<br />

applications include point of use laboratory systems,<br />

gas supply purging, and bulk gas distribution systems.<br />

SINGLE STAGE<br />

DESCRIPTION CGA NO. PART NO. PRICE<br />

0-40psig (delivery pressure) — 81890<br />

0-120psig (delivery pressure) — 81891<br />

0-200psig (delivery pressure) — 81892<br />

5246<br />

DUAL STAGE ECONOMY<br />

DESCRIPTION CGA NO. PART NO. PRICE<br />

H2, Ar/Methane 350 8101<br />

O2 540 8102<br />

He, N2, Ar, Ne 580 8103<br />

Air 590 8104<br />

Air, Breathing Quality 346 8105<br />

D) Single Stage Liquid Cylinder<br />

Regulators<br />

These regulators are suitable for primary<br />

pressure control of gases supplied from<br />

cryogenic liquid cylinders. Typical<br />

applications include regulation of liquid<br />

nitrogen, oxygen, and carbon dioxide.<br />

5247<br />

B) Dual Stage High<br />

Purity Regulators<br />

These regulators are suitable<br />

for secondary pressure control of<br />

noncorrosive or high purity gases for applications<br />

requiring constant pressure control and delivery<br />

regardless of supply pressure variations. Typical<br />

applications include gas supply purging, gas system<br />

charging, fuel gas supply control, and calibrations gas<br />

control.<br />

DUAL STAGE HIGH PURITY<br />

DESCRIPTION CGA NO. PART NO. PRICE<br />

H2, Ar/Methane 350 8109<br />

He, N2, Ar, Ne 580 8111<br />

Need Cylinder Accesories?<br />

Alltech carries cylinder accessories.<br />

See page 390 for more information.<br />

5245<br />

SINGLE STAGE LIQUID CYLINDER<br />

DESCRIPTION CGA NO. PART NO. PRICE<br />

CO2, 0-40psig 320 81899<br />

N2, 0-40psig 580 81893<br />

O2, 0-40psig 540 81897<br />

CO2, 0-120psig 320 81900<br />

N2, 0-120psig 580 81894<br />

O2, 0-120psig 540 81898<br />

E) Panel Mount Regulators<br />

These regulators can also be used in-line.<br />

Order gauges and mounting nut separately.<br />

PANEL MOUNT<br />

DESCRIPTION CGA NO. PART NO. PRICE<br />

Panel Mount Regulator — 81896<br />

Panel Mounting Nut — 81895<br />

Pressure Gauges for Panel Mount Regulators<br />

0-30psig — 86800<br />

0-60psig — 86802<br />

0-100psig — 86804<br />

0-200psig — 86808<br />

5248<br />

410<br />

Specifications for Alltech Regulators<br />

A) DUAL STAGE ECONOMY B) DUAL STAGE HIGH PURITY C) SINGLE STAGE D) SINGLE STAGE LIQUID CYLINDER E) PANEL MOUNT<br />

Body: Forged Brass Chrome-plated forged brass Chrome-plated forged brass Chrome-plated forged brass Brass<br />

Bonnet: Brass-plated die cast zinc Chrome-plated die cast zinc Chrome-plated die cast zinc Chrome-plated die cast zinc Acetal Resin<br />

Diaphragm: PTFE -lined neoprene 316L Stainless Steel 316L Stainless Steel 316L Stainless Steel Nitrile<br />

Seat & Internal Seal: PTFE PTFE PTFE PTFE Acetal Resin<br />

Mas. Inlet Pressure: 3000psig (210 bar) 3000psig (210 bar) 3000psig (210 bar) 3000psig (210 bar) 400psig<br />

Delivery Press. Range: 0-120psig 0-120psig 0-40, 0-120, or 0-200psig 0-40 or 0-120psig —<br />

Delivery Press. Gauge: 0-20psig 0-200psig 0-60, 0-200, or 0-400psig 0-60 or 0-200psig Order Separately<br />

Cylinder Press. Gauge: 0-4000 psig 0-4000psig 0-4000psig 0-4000psig 0-4000psig<br />

Temperature Range: -40 to 60°C -40 to 60°C -40 to 60°C -40 to 60°C -34 to 65°C<br />

Gauges: 2-1/2" diameter brass 2-1/2" diameter brass 2-1/2" diameter brass 2-1/2" diameter brass Order Separately<br />

Ports: 1/4" FPT 1/4" FPT 1/4" FPT 1/4" FPT 1/8" FPT<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Gas Sampling<br />

Gas Sampling Bag Selection Guide<br />

FEP Gas Sampling Bags, 5mil<br />

TENSILE STRENGTH*<br />

FITTINGS AVAILABLE (BY ASTM D-882)<br />

Barbed on/off<br />

Septum Port<br />

Dual<br />

1/4" SS Fitting<br />

2N1 Combination<br />

2,500-3000psig<br />

(Note: This is NOT<br />

a burst pressure<br />

rating for the<br />

bag.)<br />

PERMEABILITY<br />

Gas<br />

CO2<br />

Hydrogen<br />

Nitrogen<br />

Oxygen<br />

Acetic Acid<br />

Vapor<br />

Acetone<br />

Benzene<br />

CCl4<br />

Ethanol<br />

Hexane<br />

Water<br />

Permeability**<br />

1670<br />

2200<br />

320<br />

750<br />

0.41<br />

Permeability***<br />

0.95<br />

0.64<br />

0.31<br />

0.69<br />

0.56<br />

0.45<br />

TEMPERATURE<br />

RANGE (°C) SAMPLE COMPATIBILITY ADVANTAGE<br />

-240 to 260 Inert and solvent<br />

resistant to virtually<br />

all chemicals except<br />

molten alkali metals,<br />

gaseous fluorine, complex<br />

halogenated compounds<br />

at elevated pressure and<br />

temperature<br />

Low permeability to<br />

liquids, gases, moisture<br />

and organic vapors;<br />

suitable for cryogenic use<br />

Tedlar® PVF, 2mil<br />

FITTINGS AVAILABLE<br />

Barbed on/off<br />

Septum Port<br />

Dual<br />

1/4" SS Fitting<br />

2N1 Combination<br />

TENSILE STRENGTH*<br />

(BY ASTM D-882)<br />

17,000-<br />

18,000psig (Note:<br />

This is NOT a<br />

burst pressure<br />

rating for the<br />

bag.)<br />

PERMEABILITY<br />

Gas<br />

CO2<br />

Hydrogen<br />

Nitrogen<br />

Oxygen<br />

Vapor<br />

Acetic Acid<br />

Acetone<br />

Benzene<br />

CCl4<br />

Ethyl Acetate<br />

Ethanol<br />

Hexane<br />

Water<br />

Permeability**<br />

11.1<br />

150<br />

0.25<br />

3.2<br />

Permeability***<br />

45<br />

10,000<br />

90<br />

50<br />

1.000<br />

35<br />

55<br />

180<br />

TEMPERATURE<br />

RANGE (°C) SAMPLE COMPATIBILITY ADVANTAGE<br />

-234 to 300 Recommended for<br />

analysis of non-corrosive<br />

gases, TCLP gases,<br />

CO, H2S, radon, and<br />

mercaptans; “Grab”<br />

sampling; preparation<br />

of calibration gas<br />

standards; gas blending;<br />

stack sampling; emission<br />

testing<br />

Lowest permeability of all<br />

types of bags; economical<br />

alternative to PTFE; easily<br />

cleaned and reused<br />

Cali-5-Bond 5.5mil (polyethylene, polyamide, aluminum foil, polyvinyl, chloride polyester)<br />

FITTINGS AVAILABLE<br />

2N1 Combination<br />

Barbed on/off<br />

Septum Port<br />

Fittings<br />

TENSILE STRENGTH*<br />

(BY ASTM D-882)<br />

PERMEABILITY<br />

TEMPERATURE<br />

RANGE (°C) SAMPLE COMPATIBILITY ADVANTAGE<br />

— — Max. 54 Designed specifically for<br />

collecting air samples;<br />

suitable for the storage<br />

and transportation of gas<br />

samples<br />

*Tensile strength is the maximum force required to rupture a one inch wide specimen. ** cc/(100in 2 )(24hrs)(atm/mil) *** gms/(100in 2 )(24hrs/mil)<br />

Opaque bag protects<br />

sample from UV<br />

degradation; bags may be<br />

purged with nitrogen or<br />

pure air and reused<br />

Alltech offers a large variety of gas sampling bag fittings. Consider the following when selecting a fitting:<br />

1. How will you collect the sample? What type of connection is available to connect to the bag?<br />

2. How will you need to access the sample once it is collected in the bag?<br />

3. Is your sample compatible with the fitting material?<br />

6644 6642 6738 6645 6643<br />

Nickel-plated<br />

Barbed On-Off Valve<br />

PTFE Septum Port Dual On-Off/Septum 1/4" SS Swagelok ® 2N1 Combination<br />

On-Off/Septum<br />

Need a syringe? See pages 55-71 for our<br />

complete selection of syringes.<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

411


Gas Sampling<br />

A C C E S S O R I E S<br />

Gas Sampling Bags<br />

Alltech Tedlar ® Gas Sampling Bags<br />

• High tensile strength resists puncture<br />

• Low permeability minimizes sample loss<br />

Alltech Tedlar® bags are manufactured from sturdy 2mil PVF<br />

film that is inert to a wide range of gases. Low permeability<br />

ensures the integrity of your sample and makes Tedlar® bags the<br />

ideal choice for off site analysis.<br />

6647<br />

NOMINAL SIZE<br />

VOLUME<br />

BARBED ON-OFF<br />

VALVE PART NO.<br />

PRICE<br />

ALLTECH TEDLAR® GAS SAMPLING BAGS<br />

SEPTUM PORT<br />

PART NO.<br />

PRICE<br />

DUAL ON-OFF/SEPTUM<br />

PORT PART NO.<br />

PRICE<br />

1/4" SS SWAGELOK ®<br />

PART NO.<br />

6" x 6" 0.6L 41021 41023 41025 41027<br />

6" x 10" 1.2L 41029 41031 41033 41035<br />

6" x 12" 1.5L 41037 41039 41041 41043<br />

9" x 9" 2L 41045 41047 41049 41051<br />

12" x 12" 5L 41053 41055 41057 41059<br />

12" x 19" 10L 41063 41065 41067 41069<br />

18" x 18" 16L 41071 41073 41075 41077<br />

24" X 24" 40L 41079 41081 41083 41085<br />

24" x 30" 56L 41087 41089 41091 41093<br />

24" x 36" 73L 41095 41097 41099 41032<br />

30" x 30" 80L 41034 41036 41038 41042<br />

PRICE<br />

Alltech FEP Gas Sampling Bags<br />

• 5mil thickness for durability<br />

• Manufactured and packaged under GLP conditions<br />

Alltech FEP bags have a 5mil film thickness making them<br />

suitable for harsh sampling conditions. Bags are chemically<br />

resistant to the most severe corrosives. Choose from 4 different<br />

port types.<br />

6646<br />

NOMINAL SIZE<br />

VOLUME<br />

BARBED ON-OFF<br />

VALVE PART NO.<br />

PRICE<br />

ALLTECH FEP GAS SAMPLING BAGS<br />

SEPTUM PORT<br />

PART NO.<br />

PRICE<br />

DUAL ON-OFF/SEPTUM<br />

PORT PART NO.<br />

PRICE<br />

1/4" SS SWAGELOK ®<br />

PART NO.<br />

6" x 6" 0.6L 41044 41046 41048 41052<br />

6" x 10" 1.2L 41054 41056 41058 41064<br />

6" x 12" 1.5L 41066 41068 41072 41074<br />

9" x 9" 2L 41076 41078 41082 41084<br />

12" x 12" 5L 41086 41088 41092 41094<br />

12" x 19" 10L 41106 41108 41109 41125<br />

18" x 18" 16L 41127 41129 41131 41133<br />

24" x 24" 40L 41135 41137 41139 41149<br />

24" x 30" 56L 41151 41153 41155 41157<br />

24" x 36" 73L 41126 41128 41132 41134<br />

30" x 30" 80L 41136 41138 41152 41154<br />

PRICE<br />

Replacement Parts<br />

REPLACEMENT PARTS FOR TEDLAR® AND FEP BAGS<br />

DESCRIPTION PART NO. PRICE<br />

Replacement Septa for Septa Port, 10/pk 41158<br />

1/4" PTFE No Hole Ferrules for 1/4" SS Fitting, 10/pk RF-400/0-T<br />

412<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Gas Sampling<br />

Gas Sampling Bags<br />

Combo Valve Gas Sampling Bags<br />

• On/off valve and septum in one fitting<br />

• Save with convenient multi-packs<br />

Cali-5-Bond 5-Layer Gas Sampling Bags<br />

• Non-permeable<br />

• Opaque to UV and visible light<br />

• Inert, flexible, tough and reusable<br />

6648 1651<br />

Combo valve gas sampling bags give the convenience<br />

and ease of a barbed on/off valve and a septum port<br />

combined into one fitting. The valve fitting features a<br />

3/16" stem, which is suitable for use with most 1/4"<br />

tubing, and a sampling port. Bags are available in<br />

Tedlar® and FEP as well as convenient multi-packs.<br />

COMBO VALVE GAS SAMPLING BAGS<br />

SIZE VOLUME PORT DESCRIPTION PART NO. PRICE<br />

Tedlar® Gas Sampling Bags<br />

7 x 7" 1L 2N1 41001<br />

9 x 9" 2L 2N1 41003<br />

9 x 12" 3L 2N1 41005<br />

12 x 12" 5L 2N1 41007<br />

12 x 19" 10L 2N1 41011<br />

12 x 21" 12L 2N1 41013<br />

18 x 24" 25L 2N1 41017<br />

FEP Gas Sampling Bags<br />

6 x 6" 0.6L 2N1 41002<br />

6 x 10" 1.2L 2N1 41004<br />

6 x 12" 1.5L 2N1 41006<br />

9 x 9" 2L 2N1 41008<br />

12 x 12" 5L 2N1 41012<br />

12 x 19" 10L 2N1 41016<br />

18 x 18" 16L 2N1 41018<br />

SIZE<br />

TEDLAR® COMBO VALVE MULTI-PACKS<br />

VOLUME<br />

PORT<br />

DESCRIPTION QTY PART NO. PRICE<br />

7 x 7" 1L 2N1 10 48001<br />

9 x 9" 2L 2N1 10 48003<br />

12 x 12" 5L 2N1 10 48007<br />

12 x 19" 10L 2N1 10 48011<br />

18 x 24" 25L 2N1 5 48017<br />

Cali-5-bond gas sampling bags are constructed<br />

from inert 5.5mil thick material made from five layers<br />

of film. The layers are comprised of an inner layer of<br />

high-density polyethylene, followed by polyamide, an<br />

aluminum foil barrier, a polyvinylidene chloride layer and<br />

an outer layer of polyester. These bags are specifically<br />

designed for air sampling and are suitable for the storage<br />

and transportation of gas samples.<br />

Cali-5-Bond bags are available in both pillow and<br />

snout shapes. The snout provides additional entry into<br />

the bag for flushing and sample collection.<br />

Bags are equipped with a barbed on-off valve and<br />

silicone septum for easy sampling and can be purged<br />

with nitrogen or pure air gas and reused.<br />

5-LAYER GAS SAMPLING BAGS<br />

NOMINAL SIZE VOLUME PORT DESCRIPTION PART NO. PRICE<br />

Snout-Shaped Gas Sampling Bags<br />

8 x 15" 2L Barbed Valve 1" Septa 4150<br />

8 x 27" 5L Barbed Valve 1" Septa 4152<br />

16 x 16" 10L Barbed Valve 1" Septa 4186<br />

16 x 29" 22L Barbed Valve 1" Septa 4154<br />

23.5 x 28" 44L Barbed Valve 1" Septa 4156<br />

Pillow-Shaped Gas Sampling Bags<br />

8 x 8" 1L Barbed Valve 1" Septa 4188<br />

8 x 11" 2L Barbed Valve 1" Septa 4190<br />

16 x 19" 15L Barbed Valve 1" Septa 4192<br />

23.5 x 31" 60L Barbed Valve 1" Septa 4194<br />

31 x 31.5" 90L Barbed Valve 1" Septa 4196<br />

31 x 55" 170L Barbed Valve 1" Septa 4198<br />

Have a Question about Your Order?<br />

Contact Alltech Customer Service:<br />

Online Ordering 24 hours a day:<br />

www.alltechWEB.com<br />

Email: alltech@alltechemail.com<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

413


Gas Sampling<br />

A C C E S S O R I E S<br />

Gas Sampling <strong>Accessories</strong><br />

Gas Sampling Bulb with Septum Ports<br />

• PTFE stop cocks for increased compatibility<br />

GAS SAMPLING BULBS<br />

DESCRIPTION PART NO. PRICE<br />

125mL, PTFE Stopcock 7012<br />

250mL, PTFE Stopcock 7013<br />

500mL, PTFE Stopcock 7011<br />

1000mL, PTFE Stopcock 7066<br />

Replacement Septa, 12/pk 7000<br />

Gas Sampling Bulb with Twist-Lock<br />

Stopcocks<br />

• Unique twist-lock stopcocks<br />

• PTFE outlet tube connectors<br />

GAS SAMPLING BULBS<br />

DESCRIPTION PART NO. PRICE<br />

125mL, PTFE Stopcock 6950<br />

250mL, PTFE Stopcock 6952<br />

500mL, PTFE Stopcock 6954<br />

Replacement Septa, 10/pk 6900<br />

4663<br />

4664<br />

Vacuum Sampler<br />

• No external pump required<br />

• Reusable<br />

These evacuated 280mL vacuum samplers<br />

are fitted with a unique septum port and<br />

needle guide through which the container is<br />

filled and samples removed. A 4" long needle<br />

is supplied with each vacuum sampler (2<br />

needles with the package of 12 samplers).<br />

VACUUM SAMPLER<br />

DESCRIPTION PART NO. PRICE<br />

280mL (1 needle), ea 8020<br />

280mL (2 needles) 12/pk 8022<br />

Replacement Septa, 12/pk 8015<br />

Can Piercing Unit<br />

Can piercer allows small samples to be<br />

taken without significantly disturbing the<br />

equilibrium conditions in the container.<br />

The piercer can be affixed to the side of<br />

a round container with supplied steel<br />

straps.<br />

CAN PIERCING UNIT<br />

6310<br />

4667<br />

(Can not included)<br />

DESCRIPTION PART NO. PRICE<br />

Can Piercer 8013<br />

Replacement Septa, 12/pk 8015<br />

Replacement Gaskets, 12/pk 8016<br />

Gas Sampling Bulb with Injection Port &<br />

Valve Stopcocks<br />

• Stored sample contacts only glass and PTFE<br />

• Suitable for vacuum or pressure<br />

• Semi-needle valve control<br />

Gas and Vapor Sampler<br />

• Sample bags are removable and resealable<br />

Collect samples in resealable 200cc<br />

multilayer bags. Simply evacuate the can is ter<br />

using the supplied aspirator bulb. The bags can<br />

be re moved for stor age or ship ment, free ing<br />

the canister for fur ther sam pling. Ten bags are<br />

in clud ed with each kit.<br />

4668<br />

4665<br />

414<br />

GAS SAMPLING BULBS<br />

DESCRIPTION PART NO. PRICE<br />

125mL 6940<br />

250mL 6942<br />

500mL 6944<br />

13-425 Open-Hole Caps, 100/pk 73090<br />

TFE/Silicone Liners, 100/pk 98123<br />

© Copyright 2004 Alltech Associates, Inc.<br />

GAS AND VAPOR SAMPLER<br />

DESCRIPTION PART NO. PRICE<br />

Gas and Vapor Sampler Kit 4182<br />

Replacement Bags, 10/pk 4184<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Ferrules<br />

<strong>GC</strong> Ferrule Selection<br />

PTFE Ferrules<br />

PTFE ferrules are completely inert and an economical<br />

choice. They have an upper temperature limit of 250°C.<br />

PTFE ferrules conform well to the shape of the column<br />

upon compression and can be reused if handled carefully.<br />

Graphite Ferrules<br />

These 99.95% pure graphite ferrules can be used at<br />

temperatures up to 450°C without producing bleed or<br />

decomposition products. The one-piece design requires<br />

no back ferrules. Graphite ferrules are very soft and<br />

conform well to the column on compression. These<br />

ferrules can be reused as long as care is taken not to<br />

overtighten them.<br />

Vespel ® Ferrules<br />

Vespel® ferrules do not cold flow, are easily reusable,<br />

and withstand temperature up to 350°C. At high<br />

temperatures, Vespel® may adhere to glass or metal.<br />

Vespel ® /Graphite Ferrules<br />

Composites of Vespel ® and graphite combine the<br />

advantages of the two materials. They are less likely to<br />

adhere to the column than Vespel® but are more durable<br />

than graphite. Ferrules are easy to reuse and stable at<br />

temperatures to 400°C.<br />

Two types of composites are available. The VG1<br />

composite is 85% Vespel ® /15% graphite and suitable for<br />

all-purpose applications. The VG2 type is 60% Vespel®/<br />

40% graphite and exhibits added lubricity.<br />

Ferrule Properties<br />

MATERIAL TEMP. LIMIT REUSABILITY RESEALING PROPERTIES SUITABILITY FOR GLASS TEMP. PROG.<br />

PTFE 250°C Good Excellent Excellent No<br />

Graphite 450°C Good Excellent Excellent Yes<br />

Vespel® 350°C+ Excellent Good Good Yes<br />

VG1 400°C Excellent Good Excellent Yes<br />

VG2 400°C Excellent Good Excellent Yes<br />

What ferrule type do you need?<br />

FERRULE TYPE<br />

0.4mm Hole:<br />

0.5mm Hole:<br />

0.8mm Hole:<br />

NO-HOLE:<br />

2-HOLE:<br />

USE FOR:<br />

Capillaries with i.d. of 0.10-0.25mm<br />

Capillaries with i.d. of 0.28-0.35mm<br />

Capillaries with i.d. of 0.45-0.53mm<br />

As plugs, or drill for special needs<br />

Connecting 2 pieces of capillary tubing<br />

or columns to the same fitting end<br />

PTFE AND GRAPHITE FERRULES<br />

DESCRIPTION FITTING SIZE TUBING SIZE QTY PTFE PART NO. PRICE GRAPHITE PART NO. PRICE<br />

Straight Ferrules<br />

1" 1" 2 — — 14361<br />

7/8" 7/8" 2 — — 14360<br />

3/4" 3/4" 2 — — 14358<br />

5/8" 5/8" 2 — — 14357<br />

Used when 1/2" 1/2" 10 — — SF-800-G<br />

the tubing 3/8" 3/8" 10 SF-600-T SF-600-G<br />

o.d. matches<br />

1/4" 1/4" 10 SF-400-T SF-400-G<br />

the nominal<br />

size of the<br />

3/16" 3/16" 10 SF-300-T SF-300-G<br />

fitting being 1/8" 1/8" 10 SF-200-T SF-200-G<br />

used.<br />

1/16" 1/16" 10 SF-100-T SF-100-G<br />

Reducing Ferrules<br />

1/4" 1/16" 10 RF-400/100-T RF-400/100-G<br />

1/4" 0.8mm 10 — — RF-400/0.8-G<br />

1/4" 1/8" 10 RF-400/200-T RF-400/200-G<br />

1/4" 3/16" 10 RF-400/300-T 14327<br />

1/4" 4mm 10 — — 14384<br />

Used when<br />

the tubing<br />

o.d. is smaller<br />

than the<br />

nominal<br />

size of the<br />

fittings.<br />

1/4" 6mm 10 RF-400/6MM-T RF-400/6MM-G<br />

1/8" 1/16" 10 RF-200/100-T RF-200/100-G<br />

1/8" 1.2mm 10 — — 14326<br />

1/8" 1.0mm 10 — — 14311<br />

1/8" 0.8mm 10 — — RF-200/0.8-G<br />

1/8" 0.5mm 10 — — RF-200/0.5-G<br />

1/8" 0.4mm 10 — — RF-200/0.4-G<br />

1/8" 1.2mm 10 — — 14305<br />

1/16" 1.0mm 10 — — RF-100/1.0-G<br />

1/16" 0.8mm 10 — — RF-100/0.8-G<br />

1/16" 0.5mm 10 — — RF-100/0.5-G<br />

1/16" 0.4mm 10 — — RF-100/0.4-G<br />

1/16" 0.3mm 10 — — 14308<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

415


Ferrules<br />

A C C E S S O R I E S<br />

PTFE AND GRAPHITE FERRULES (CONT’D)<br />

DESCRIPTION FITTING SIZE TUBING SIZE QTY PTFE PART NO. PRICE GRAPHITE PART NO. PRICE<br />

HP/Agilent Short Ferrules<br />

1/16" 1.2mm 10 — — 14370<br />

1/16" 1.0mm 10 — — 14325<br />

1/16" 0.8mm 10 — — 14324<br />

1/16" 0.5mm 10 — — 14323<br />

1/16" 0.4mm 10 — — 14322<br />

1/16" 0.3mm 10 — — 14321<br />

Two-Hole Ferrules<br />

1/8" 0.8mm 10 — — 14334<br />

1/8" 0.5mm 10 — — 14307<br />

1/16" 0.5mm 10 — — 14330<br />

No-Hole Ferrules<br />

3/8" 10 — 14332<br />

1/4" 10 RF-400/0-T 14328<br />

1/8" 10 RF-200/0-T 14314<br />

1/16" 10 RF-100/0-T 14310<br />

Graphite Ferrules for HP/Agilent Nuts<br />

0.5mm 10 — — 1547901<br />

1.0mm Hole 10 — — 1548001<br />

DESCRIPTION<br />

FITTING<br />

SIZE TUBING SIZE QTY<br />

VESPEL ® AND VESPEL ® /GRAPHITE FERRULES<br />

VESPEL ®<br />

PART NO.<br />

PRICE<br />

VG1<br />

PART NO.<br />

PRICE<br />

VG2<br />

PART NO.<br />

Straight Ferrules<br />

1/4" 1/4" 10 SF-400-V SF-400-VG1 SF-400-VG2<br />

1/4" 1/4" 10 15449* 15449* 15451*<br />

1/8" 1/8" 10 SF-200-V SF-200-VG1 SF-200-VG2<br />

1/8" 1/8" 10 — — 15450* 15452*<br />

1/16" 1/16" 10 SF-100-V SF-100-VG1 SF-100-VG2<br />

Reducing Ferrules<br />

1/4" 6mm 10 RF-400/6MM-V 400/6MM-VG1 400/6MM-VG2<br />

1/4" 3/16" 10 RF-400/300-V 400/300-VG1 400/300-VG2<br />

1/4" 1/8" 10 RF-400/200-V 400/200-VG1 400/200-VG2<br />

1/4" 1/16" 10 RF-400/100-V 400/100-VG1 400/100-VG2<br />

1/4" 0.8mm 10 — — 400/0.8-VG1 400/0.8-VG2<br />

1/8" 1/16" 10 RF-200/100-V 200/100-VG1 200/100-VG2<br />

1/8" 0.8mm 10 — — 200/0.8-VG1 200/0.8-VG2<br />

1/8" 0.5mm 10 — — 200/0.5-VG1 200/0.5-VG2<br />

1/8" 0.4mm 10 — — 200/0.4-VG1 200/0.4-VG2<br />

1/16" 1.0mm 10 RF-100/1.0-V 100/1.0-VG1 100/1.0-VG2<br />

1/16" 0.9mm 10 RF-100/0.9-V 100/0.9-VG1 100/0.9-VG2<br />

1/16" 0.8mm 10 RF-100/0.8-V 100/0.8-VG1 100/0.8-VG2<br />

1/16" 0.5mm 10 RF-100/0.5-V 100/0.5-VG1 100/0.5-VG2<br />

1/16" 0.4mm 10 RF-100/0.4-V 100/0.4-VG1 100/0.4-VG2<br />

1/16" 0.3mm 10 — — 100/0.3-VG1 — —<br />

No-Hole Ferrules<br />

1/4" — 10 RF-400/0-V 400/0-VG1 400/0-VG2<br />

1/8" — 10 RF-200/0-V 200/0-VG1 200/0-VG2<br />

1/16" — 10 RF-100/0-V 100/0-VG1 100/0-VG2<br />

Two-Hole Ferrules<br />

1/16" 0.5mm 10 — — 15486 15488<br />

1/16" 0.4mm 10 — — 15481 15487<br />

* Equivalent to Parker one-piece metal ferrule.<br />

PRICE<br />

416<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Fittings<br />

Fittings Selection Guide<br />

To determine the size of a nut or female pipe thread, compare it to the silhouettes below. To determine the size<br />

of a ferrule, measure its inside diameter. Please note that tubing fitting sizes are based on the outside diameter of<br />

the tube, while pipe thread fitting sizes are based on the inside dimension of the pipe. Pipe and tubing fittings are<br />

not interchangeable.<br />

Tubing Nut Sizes<br />

1/16" 1/8" 3/16" 1/4" 3/8" 1/2"<br />

0127<br />

Female Pipe Thread Connectors<br />

Tubing<br />

Tubing<br />

* Silhouettes shown at actual size<br />

Parker Fittings<br />

1/8" FPT<br />

1/8" (6-2-GBG) 1/4" FPT 3/8" FPT 1/2" FPT<br />

5767<br />

Parker fittings are available in two forms: the CPI one-piece ferrule and the A-Lok two piece ferrule. Most parts<br />

are available in brass or stainless steel and should be matched to the tubing, particularly in thermal applications.<br />

PARKER FITTINGS<br />

DESCRIPTION DIMENSIONS QTY<br />

Nuts<br />

Ferrules<br />

CPI<br />

Tees<br />

A-LOK<br />

© Copyright 2004 Alltech Associates, Inc.<br />

A-LOK<br />

BRASS<br />

PART NO.<br />

PRICE<br />

CPI<br />

BRASS<br />

PART NO. PRICE QTY<br />

A-LOK<br />

SS<br />

PART NO.<br />

PRICE<br />

CPI<br />

SS<br />

PART NO.<br />

1/16" 10/pk 11600 14057 10/pk 11700 141575<br />

1/8" 10/pk 11601 14058 10/pk 11701 14158<br />

3/16" 10/pk 11602 60000 10/pk 11702 61000<br />

1/4" 10/pk 11603 14059 10/pk 11703 14159<br />

3/8" 10/pk 11604 60002 10/pk 11704 610025<br />

1/2" 10/pk 11605 600045 5/pk 11705 610045<br />

1/16" 10/pk 11606 14060 10/pk 11706 141605<br />

1/8" 10/pk 11607 14061 10/pk 11707 14161<br />

3/16" 10/pk 11608 60006 10/pk 11708 61006<br />

1/4" 10/pk 11609 14062 10/pk 11709 14162<br />

3/8" 10/pk 11610 60008 10/pk 11710 610085<br />

1/2" 5/pk 11611 600105 5/pk 11711 610105<br />

1/16" ea 11612 14075 ea 11712 14175<br />

1/8" ea 11613 14053 ea 11713 14176<br />

3/16" ea 11614 60012 ea 11714 61012<br />

1/4" ea 11615 14077 ea 11715 14177<br />

3/8" ea 11616 60014 ea 11716 61014<br />

1/2" ea 11617 60016 ea 11717 61016<br />

PRICE<br />

Contact your Alltech office or distributor for current or local prices.<br />

417


Fittings<br />

A C C E S S O R I E S<br />

PARKER FITTINGS (CONT'D)<br />

DESCRIPTION DIMENSIONS QTY<br />

Unions<br />

Reducing Unions<br />

Capillary Union<br />

A-LOK<br />

BRASS<br />

PART NO.<br />

PRICE<br />

CPI<br />

BRASS<br />

PART NO. PRICE QTY<br />

A-LOK<br />

SS<br />

PART NO.<br />

PRICE<br />

CPI<br />

SS<br />

PART NO.<br />

1/16" ea 11618 14063 ea 11718 14163<br />

1/8" ea 11619 14065 ea 11719 14165<br />

3/16" ea 11620 60018 ea 11720 61018<br />

1/4" ea 11621 14068 ea 11721 14168<br />

3/8" ea 11622 60020 ea 11722 61020<br />

1/2" ea 11623 60022 ea 11723 61022<br />

1/8" to 1/16" ea 11624 14064 ea 11724 14164<br />

3/16" to 1/8" ea 11625 60024 ea 11725 61024<br />

1/4" to 1/16" ea 11626 60026 ea 11726 14166<br />

1/4" to 1/8" ea 11627 60028 ea 11727 61028<br />

1/4" to 3/16" ea 11628 14067 ea 11728 14167<br />

3/8" to 1/16" ea — — — — ea 11729 14174<br />

3/8" to 1/4" ea 11630 60030 ea 11730 61030<br />

1/16" ea — — — — ea — 28812<br />

PRICE<br />

418<br />

Female Pipe Thread Connectors (Tube to FPT)<br />

1/8" to 1/8" FPT ea 11800 60048 ea 11750 61048<br />

1/8" to 1/4" FPT ea 11801 14071 ea 11751 61084<br />

1/4" to 1/8" FPT ea 11802 60050 ea 11752 61050<br />

1/4" to 1/4" FPT ea 11803 14072 ea 11753 61086<br />

3/16" to 1/8" FPT ea 11804 60052 ea 11754 61052<br />

3/8" to 1/8" 6-2-GBZ ea 11805 60054 ea 11755 61054<br />

3/8" to 1/4" FPT ea 11806 60056 ea 11756 61056<br />

Male Pipe Thread Connectors (Tube to MPT)<br />

1/16" to 1/16" MPT ea 11632 60034 ea 11732 61034<br />

1/16" to 1/8" MPT ea 11633 60036 ea 11733 61036<br />

1/8" to 1/8" MPT ea 11634 60038 ea 11734 61038<br />

1/8" to 1/4" MPT ea 11635 60039 ea 11735 61039<br />

3/16" to 1/8" MPT ea 11636 60040 ea 11736 61040<br />

1/4" to 1/8" MPT ea 11637 60042 ea 11737 61042<br />

3/8" to 1/8" MPT ea 11638 60044 ea 11738 61044<br />

1/4" to 1/4" MPT ea 11639 14069 ea 11739 61082<br />

3/8" to 1/4" MPT ea 11640 60046 ea 11740 61046<br />

Tube End Connectors (Reducers)<br />

1/16" to 1/8" tube ea 11807 60058 ea 11757 61058<br />

1/16" to 1/4" tube ea — — — — ea 11758 61059<br />

1/8" to 1/4" tube ea 11809 60060 ea 11759 61060<br />

1/8" to 3/16" tube ea 11810 60062 ea 11770 61062<br />

3/16" to 1/4" tube ea 11811 4052 ea 11771 61064<br />

1/4" to 1/8" tube ea 11812 14073 ea 11772 14169<br />

1/4" to 3/8" tube ea 11813 60066 ea 11773 61066<br />

3/8" to 1/4" tube ea 11814 60068 ea 11774 61068<br />

Caps<br />

1/16" ea 11815 14047 ea 11835 14151<br />

1/8" ea 11816 14051 ea 11836 14152<br />

3/16" ea 11817 60070 ea 11837 61070<br />

1/4" ea 11818 14052 ea 11838 14153<br />

3/8" ea 11819 60072 ea 11839 61072<br />

1/2" ea 11820 60074 ea 11840 61074<br />

Plugs<br />

1/16" ea 11821 14054 ea 11841 14154<br />

1/8" ea 11822 14055 ea 11842 14155<br />

3/16" ea 11823 60076 ea 11843 61076<br />

1/4" ea 11824 14066 ea 11844 14156<br />

3/8" ea 11825 60078 ea 11845 61078<br />

1/2" ea 11826 60080 ea 11846 61080<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Fittings<br />

SWAGELOK ® Tube Fittings<br />

SWAGELOK® Tube Fittings provide a leak-proof,<br />

torque-free seal at all tubing connections and eliminate<br />

costly, hazardous leaks in instrumentation and process<br />

tubing.<br />

All the action in the fitting moves along the tube<br />

axially instead of with a rotary motion. Since no torque<br />

is transmitted from the fitting to the tubing, there is no<br />

initial strain which might weaken the tubing.<br />

CAUTION: Do not mix or<br />

interchange parts of tube<br />

fittings made by other<br />

manufacturers with SWAGELOK®<br />

tube fitting parts.<br />

SWAGELOK® FITTINGS<br />

DESCRIPTION DIMENSIONS QTY BRASS PART NO. PRICE QTY<br />

Nuts<br />

Male Nut<br />

STAINLESS STEEL<br />

PART NO.<br />

1/16" 10 55002 10 55199<br />

1/8" 10 55003 10 55193<br />

3/16" 10 55004 10 55194<br />

1/4" 10 55005 10 55195<br />

1/16" ea 55084 ea 55184<br />

PRICE<br />

Front Ferrules<br />

Back Ferrules<br />

Union (Low Dead Volume)<br />

1/16" 10 55006 10 55196<br />

1/8" 10 55007 10 55197<br />

3/16" 10 55008 10 55198<br />

1/4" 10 55013 10 55093<br />

1/16" 10 55014 10 55094<br />

1/8" 10 55015 10 55095<br />

3/16" 10 55016 10 55096<br />

1/4" 10 55017 10 55097<br />

1/16" ea 55001 ea 55101<br />

Unions<br />

Bulkhead Unions<br />

Reducing Unions<br />

1/16" ea 55009 ea 55109<br />

1/8" ea 55010 ea 55110<br />

3/16" ea 55011 ea 55114<br />

1/4" ea 55012 ea 55112<br />

1/16" ea 51017 ea 55117<br />

1/8" ea 55018 ea 55118<br />

3/16" ea 55019 ea 55119<br />

1/4" ea 55020 ea 55120<br />

1/8" to 1/16" ea 55021 ea 55121<br />

3/16" to 1/16" ea 55022 ea 55122<br />

3/16" to 1/8" ea 55023 ea 55123<br />

1/4" to 1/16" ea 55024 ea 55124<br />

1/4" to 1/8" ea 55025 ea 55125<br />

1/4" to 3/16" ea 55026 ea 55126<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

419


Fittings<br />

A C C E S S O R I E S<br />

SWAGELOK® FITTINGS (CONT’D)<br />

DESCRIPTION DIMENSIONS QTY BRASS PART NO. PRICE QTY<br />

Female Pipe Thread Connectors (Tube to FPT )<br />

STAINLESS STEEL<br />

PART NO.<br />

1/8" to 1/8" FPT ea 55046 ea 55146<br />

1/8" to 1/4" FPT ea 55047 ea 55147<br />

3/16" to 1/8" FPT ea 55048 ea 55148<br />

1/4" to 1/8" FPT ea 55049 ea 55149<br />

1/4" to 1/4" FPT ea 55050 ea 55150<br />

1/4" to 3/8" FPT ea 55051 ea 55151<br />

1/4" to 1/2" FPT ea 55052 ea 55152<br />

Male Pipe Thread Connectors (Tube to MPT)<br />

1/16" to 1/16" MPT ea 55033 ea 55133<br />

1/16" to 1/8" MPT ea 55034 ea 55134<br />

1/8" to 1/16" MPT ea 55035 ea 55135<br />

1/8" to 1/8" MPT ea 55036 ea 55136<br />

1/8" to 1/4" MPT ea 55037 ea 55137<br />

1/8" to 3/8" MPT ea 55038 ea 55138<br />

3/16" to 1/8" MPT ea 55039 ea 55139<br />

3/16" to 1/4" MPT ea 55040 ea 55140<br />

1/4" to 1/16" MPT ea 55041 ea 55141<br />

1/4" to 1/8" MPT ea 55042 ea 55142<br />

1/4" to 1/4" MPT ea 55043 ea 55143<br />

1/4" to 3/8" MPT ea 55044 ea 55144<br />

1/4" to 1/2" MPT ea 55045 ea 55145<br />

Tees<br />

1/16" ea 55027 ea 55127<br />

1/8" ea 55028 ea 55128<br />

3/16" ea 55029 ea 55129<br />

1/4" ea 55030 ea 55130<br />

Crosses<br />

1/8" ea 55031 ea 55131<br />

PRICE<br />

1/4" ea 55032 ea 55132<br />

Caps<br />

Plugs<br />

1/16" ea 55085 ea 55185<br />

1/8" ea 55086 ea 55186<br />

3/16" ea 55087 ea 55187<br />

1/4" ea 55088 ea 55188<br />

1/16" ea 55089 ea 55189<br />

1/8" ea 55090 ea 55190<br />

3/16" ea 55091 ea 55191<br />

1/4" ea 55092 ea 55192<br />

Need Tubing?<br />

See pages 422-424 for<br />

a complete selection of<br />

stainless steel, metal, and<br />

polymeric tubing.<br />

Need Technical Assistance?<br />

Contact Alltech Tech Support:<br />

Email: tech_service@alltechemail.com<br />

Online: www.alltechWEB.com<br />

420<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Fittings<br />

Specialty Fittings<br />

Brass Quick-Connects<br />

PFA Fittings<br />

PFA fittings offer superior chemical resistance. The<br />

one-piece ferrule and nut assembly allows for easy<br />

tubing connections. Maximum temperature rating<br />

is 250°C. Order a grooving tool (to groove tubing)<br />

separately below to achieve maximum pressure rating of<br />

125psig.<br />

PFA FITTINGS<br />

DESCRIPTION SIZE QTY PART NO. PRICE<br />

Ferrule Nut<br />

1/16" 5 45700<br />

1/8" 5 45701<br />

1/4" 5 45702<br />

Union<br />

1/16" 2 45715<br />

1/8" 2 45716<br />

1/4" 2 45717<br />

Reducing Union<br />

1/8"-1/16 2 45720<br />

1/4"-1/8" 2 45721<br />

Use Quick-Connects where gas lines are frequently<br />

broken and reassembled for convenient handling and<br />

to avoid air contamination in the gas line. Both ends<br />

of the fitting are completely shut off when the ends<br />

are separated and flow is automatically started when<br />

recoupled. Fittings are constructed of brass with Buna-<br />

N® seals. Maximum coupled pressure is 3000psig.<br />

SS Quick-Connects<br />

BRASS QUICK-CONNECTS<br />

DESCRIPTION PART NO. PRICE<br />

1/8" 7088<br />

1/4" 7089<br />

4855<br />

Tee<br />

Grooving Tool<br />

1/16" ea 45725<br />

1/8" ea 45726<br />

1/4" ea 45727<br />

1/8" ea 45746<br />

1/4" ea 45747<br />

These quick connects are 100% helium leak tested for<br />

optimum performance. They feature leak-tight Viton ®<br />

o-ring seals with a temperature range of -29 to 204°C.<br />

Simple push-pull action connects and disconnects lines<br />

without leakage. Fittings are rated for 3000psig when<br />

coupled.<br />

6693<br />

Wrench-Free <strong>GC</strong> Fittings<br />

• Special reusable ferrules<br />

• Star knob grip seals<br />

finger tight<br />

These fittings provide leakfree<br />

connections without the use of wrenches.<br />

The easy-grip star knob is designed for use with<br />

bulky, heat resistant gloves. A special graphite ferrule<br />

with a stainless steel sleeve is provided with the 1/4"<br />

kit; a specially designed Vespel®/Graphite ferrule is<br />

provided with the 1/8" kit (Both sizes can be used at<br />

temperatures up to 400°C.).<br />

5077<br />

SS QUICK-CONNECTS<br />

DESCRIPTION PART NO. PRICE<br />

1/8" 7092<br />

1/4" 7093<br />

PTFE Tape<br />

Use PTFE tape for a dry thread<br />

lubricant and sealant when making<br />

pipe thread (NPT) connections.<br />

Temperature limit is 200˚C.<br />

WRENCH-FREE <strong>GC</strong> FITTINGS<br />

DESCRIPTION PART NO. PRICE<br />

1/4" Wrench-Free<br />

Fitting Kit (2 Fittings, 4 Ferrules) 32004<br />

Repl. Ferrules, 5/pk 32002<br />

1/8" Wrench-Free<br />

Fitting Kit (2 Fittings, 4 Ferrules) 32006<br />

Repl. Ferrules, 5/pk 32008<br />

© Copyright 2004 Alltech Associates, Inc.<br />

PTFE TAPE<br />

DESCRIPTION QTY PART NO. PRICE<br />

1/2" x 260"L ea 3226<br />

1/2" x 260"L 12 Rolls 3227<br />

Contact your Alltech office or distributor for current or local prices.<br />

5078<br />

421


Tubing<br />

A C C E S S O R I E S<br />

Choosing a Tubing Material<br />

A number of options are available for packed column tubing. The most inert material is glass, which should<br />

be used for active compounds. Glass-lined tubing and AT-steel provide the inert surface of glass combined<br />

with the mechanical strength of a metal column.<br />

Metal tubing provides an economical and rugged column for suitable application. Passivated nickel tubing<br />

can frequently be used with active compounds such as phenols and amines. Stainless steel tubing is<br />

recommended for hydrocarbon, fixed gas, and solvent analyses where column inertness is less of a concern.<br />

PTFE tubing is extremely inert, but due to temperature limitations and poor column efficiency, PTFE is<br />

generally only recommended for the analysis of corrosive gases which are too reactive for glass.<br />

Stainless Steel Tubing<br />

AT Steel - Activity Tested Steel Tubing<br />

Delivers the Strength of Stainless Steel and the Inertness of Deactivated Fused Silica<br />

• Flexible, and strong • Maximum temperature limit of 340°C to 350°C<br />

A combination of chemical vapor deposition techniques and silicone chemistries transform<br />

durable stainless steel tubing into a chromatographically inert material. AT Steel activity<br />

tested steel tubing is suitable for sample loops, transfer lines, capillary and packed <strong>GC</strong> columns.<br />

AT -Steel may be cut with standard tubing cutters or high speed wheel cutters and can be<br />

rinsed with common solvents to remove particulates and contamination that have built up<br />

during use. To ensure a truly inert pathway, use AT -Steel treated fittings. Sold separately below.<br />

5105<br />

AT STEEL TUBING<br />

I.D. 6FT LENGTH PART NO. PRICE 25FT LENGTH PART NO. PRICE 50FT LENGTH PART NO. PRICE 100FT LENGTH PART NO. PRICE<br />

1/32" o.d. Tubing<br />

0.021" 11085 11086 11087 11088<br />

1/16" o.d. Tubing<br />

0.010" 11060 11061 11062 11063<br />

0.020" 11064 11065 11066 11067<br />

0.030" 11068 11069 11070 11071<br />

0.040" 11072 11073 11074 — —<br />

1/8" o.d. Tubing<br />

0.085" 11076 11077 11078 — —<br />

1/4" o.d. Tubing<br />

0.210" 11092 11093 — — — —<br />

AT -STEEL UNIONS<br />

DESCRIPTION PART NO. PRICE<br />

1/8" - 1/16 Reducing Union 11080<br />

1/16" Union 11081<br />

1/8" Union 11082<br />

Hi-EFF ® Grade Stainless Steel Tubing<br />

• Acetone washed to remove residual contaminants<br />

AT -STEEL TEES<br />

DESCRIPTION PART NO. PRICE<br />

1/16" Tee 11083<br />

1/8" Tee 11084<br />

Fittings are Parker A-Lok fittings with two-piece ferrules that have been chemically<br />

modified for improved inertness.<br />

HI-EFF ® Stainless Steel tubing meets the exact specification required to fabricate <strong>GC</strong><br />

columns. Tubing is specially tempered for easy bending. Type 304 is the most commonly used<br />

for <strong>GC</strong>. Type 316 offers more corrosion resistance.<br />

422<br />

© Copyright 2004 Alltech Associates, Inc.<br />

HI-EFF® TUBING<br />

O.D. I.D. PER FT* PART NO. PRICE PER METER PART NO. PRICE 50FT COIL PART NO. PRICE<br />

Type 316 SS<br />

1/8” (3.18mm) 0.085" (2.16mm) 30105 30107 30109<br />

1/4" (6.35mm) 0.210" (5.33mm) 30307 30308 30309<br />

Type 304 SS<br />

1/8" (3.18mm) 0.085" (2.16mm) 30102 30104 30106<br />

1/4" (6.35mm) 0.210" (5.33mm) 30302 30304 30306<br />

*Minimum tubing order is 3 ft<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Tubing<br />

Stainless Steel Tubing<br />

Standard Grade Stainless Steel Tubing<br />

• Economical<br />

• Same as HI-EFF ® without washing<br />

5098<br />

Alltech Can Provide an Acetone<br />

Washing Service<br />

Remove residual contaminants from<br />

any tubing surface between 1/8" and<br />

3/8" o.d. and up to 50' coils. Order Part<br />

Number C-3001.<br />

PER FT*<br />

PART NO.<br />

STANDARD STAINLESS STEEL TUBING<br />

PER METER<br />

50FT COIL<br />

200FT COIL<br />

O.D.<br />

I.D.<br />

PRICE PART NO. PRICE PART NO. PRICE PART NO. PRICE<br />

Type 316 SS<br />

1/32" (0.79mm) 0.007" (0.18mm) 8195 81953 81951 — —<br />

0.004" (0.10mm) 30211 30213 30212 — —<br />

0.007" (0.18mm) 30141 301430 30142 — —<br />

0.010" (0.25mm) 30051 300530 3005 30052<br />

1/16" (1.59mm) 0.020" (0.51mm) 3002100 300230 3002 300220<br />

0.030" (0.76mm) 300010 300030 3000 300020<br />

0.040" (1.02mm) 30031 30033 3003 — —<br />

0.050" (1.27mm) 30041 30043 3004 — —<br />

Type 304 SS<br />

1/8" (3.18mm) 0.085" (2.16mm) 30101 30103 3010 30108<br />

3/16" (4.76mm) 0.147" (3.73mm) 30201 30203 3020 — —<br />

1/4" (6.35mm) 0.210" (5.33mm) 30301 30303 3030 — —<br />

3/8" (9.53mm) 0.305" (7.75mm) 30321 30323 3032 † — —<br />

*Minimum tubing order is 3ft<br />

†<br />

40 ft coil<br />

Straight Stainless Steel Tubing<br />

• Type 304 SS<br />

• 6ft or 10ft lengths<br />

5097<br />

PTFE-Coated Stainless Steel Tubing<br />

• Sturdy SS tube with 0.001" thick PTFE<br />

coating<br />

• Must be preconditioned at 250°C for<br />

three hours<br />

5103<br />

STRAIGHT STAINLESS STEEL TUBING<br />

O.D. I.D. LENGTH* QTY PART NO. PRICE<br />

1/8" (3.18mm) 0.085" (2.16mm) 6 ft 10 30106ST<br />

1/8" (3.18mm) 0.085" (2.16mm) 10 ft 10 301010ST<br />

1/4" (6.35mm) 0.210" (5.33mm) 6 ft 10 30306ST<br />

1/4" (6.35mm) 0.210" (5.33mm) 10 ft 10 303010ST<br />

*10ft lengths must ship via motor freight<br />

PTFE-COATED STAINLESS STEEL TUBING<br />

O.D. I.D. LENGTH PART NO. PRICE<br />

1/8" (3.18mm) 0.085"(2.16mm) per ft* 31421<br />

1/8" (3.18mm) 0.085"(2.16mm) 50 ft 3142<br />

1/4" (6.35mm) 0.210"(5.33mm) per ft* 31441<br />

1/4" (6.35mm) 0.210"(5.33mm) 50 ft 3144<br />

*Minimum tubing order is 3 ft<br />

Glass-Lined Stainless Steel<br />

Tubing (GLT)<br />

• Flow lines for corrosives<br />

• <strong>GC</strong>/MS interfaces<br />

• Capillary column connections<br />

5101<br />

PTFE-Lined Stainless Steel Tubing<br />

• Ideal for use with reactive chemicals<br />

and for trace quantities of water<br />

• Order PTFE ferrules to grip SS and PTFE<br />

portions of tubing below<br />

5102<br />

GLASS-LINED STAINLESS STEEL TUBING<br />

O.D. I.D. LENGTH PART NO. PRICE<br />

1/16" (1.59mm) 0.3mm 180cm 3137<br />

1/16" (1.59mm) 0.5mm 180cm 3164<br />

1/16" (1.59mm) 0.7mm 180cm 3139<br />

1/8" (3.18mm) 0.75mm 180cm 3166<br />

1/8" (3.18mm) 1.0mm 180cm 3168<br />

1/8" (3.18mm) 1.5mm 180cm 3170<br />

1/8" (3.18mm) 1.8mm 180cm 3141<br />

1/4" (6.35mm) 4.0mm 180cm 3149<br />

© Copyright 2004 Alltech Associates, Inc.<br />

PTFE-LINED STAINLESS STEEL TUBING<br />

O.D. I.D. LENGTH QTY PART NO. PRICE<br />

1/8" (3.18mm) 0.070" (1.78mm) 6 ft 1 3152<br />

1/8" (3.18mm) 0.070" (1.78mm) 10 ft 1 3154<br />

1/4" (6.35mm) 0.180" (4.57mm) 6 ft 1 3156<br />

1/4" (6.35mm) 0.180" (4.57mm) 50 ft 1 3158<br />

PTFE FERRULES<br />

O.D. QTY PART NO. PRICE<br />

1/8" 10 6552<br />

1/4" 10 6554<br />

Contact your Alltech office or distributor for current or local prices.<br />

423


Tubing<br />

A C C E S S O R I E S<br />

Metal Tubing<br />

Aluminum Tubing<br />

• Economical choice for <strong>GC</strong> gas lines<br />

5106<br />

Polymeric Tubing<br />

• Maximum<br />

Inertness<br />

PFA FEP PTFE POLYPROPYLENE<br />

ALUMINUM TUBING<br />

O.D. I.D. LENGTH PART NO. PRICE<br />

1/8" (3.18mm) 0.065" (1.65mm) 50ft 3090<br />

3/16" (4.76mm) 0.128" (3.25mm) 50ft 3100<br />

1/4" (6.35mm) 0.190" (4.83mm) 50ft 3110<br />

3/8" (9.53mm) 0.315" (8.00mm) 50ft 3120<br />

Copper Tubing<br />

• Economical choice for <strong>GC</strong> gas lines<br />

COPPER TUBING<br />

O.D. I.D. LENGTH PART NO. PRICE<br />

1/8" (3.18mm) 0.065" (1.65mm) 50ft 3040<br />

3/16" (4.76mm) 0.128" (3.25mm) 50ft 30509<br />

1/4" (6.35mm) 0.190" (4.83mm) 50ft 30609<br />

3/8" (9.53mm) 0.315" (8.00mm) 50ft 30709<br />

5100<br />

PFA (Perfluoroalkoxy) Tubing<br />

PFA (PERFLUOROALKOXY) TUBING<br />

O.D. I.D. LENGTH PART NO. PRICE<br />

1/16" (1.59mm) 0.030" (0.76mm) 25 ft 45734<br />

1/8" (3.18mm) 0.062" (1.57mm) 25 ft 45735<br />

1/4" (6.35mm) 0.156" (3.96mm) 25 ft 45736<br />

FEP (Fluorinated Ethylene Polypropylene)<br />

Tubing<br />

FEP (FLUORINATED ETHYLENE POLYPROPYLENE) TUBING<br />

O.D. I.D. LENGTH PART NO. PRICE<br />

1/16" (1.59mm) 0.030" (0.76mm) 25 ft 45739<br />

1/8" (3.18mm) 0.062" (1.57mm) 25 ft 45740<br />

1/4" (6.35mm) 0.156" (3.96mm) 25 ft 45741<br />

5104a<br />

424<br />

Nickel Tubing<br />

• Pure Nickel 200, more inert than<br />

stainless steel<br />

• Acid washed and rinsed for additional<br />

inertness<br />

NICKEL TUBING<br />

O.D. I.D. PART NO. PRICE<br />

Per Foot*<br />

1/16" (1.59mm) 0.010" (0.25mm) 30831<br />

1/16" (1.59mm) 0.020" (0.51mm) 31311<br />

1/16" (1.59mm) 0.040" (1.02mm) 30851<br />

1/8" (3.18mm) 0.083" (2.11mm) 30801<br />

1/4" (6.35mm) 0.210" (5.33mm) 30811<br />

Per Meter<br />

1/16" (1.59mm) 0.010" (0.25mm) 30833<br />

1/16" (1.59mm) 0.020" (0.51mm) 31313<br />

1/16" (1.59mm) 0.040" (1.02mm) 30853<br />

1/8" (3.18mm) 0.083" (2.11mm) 30803<br />

1/4" (6.35mm) 0.210" (5.33mm) 30813<br />

50 Foot Coil<br />

1/16" (1.59mm) 0.010" (0.25mm) 3083<br />

1/16" (1.59mm) 0.020" (0.51mm) 3131<br />

1/16" (1.59mm) 0.040" (1.02mm) 3085<br />

1/8" (3.18mm) 0.083" (2.11mm) 3080<br />

1/4" (6.35mm) 0.210" (5.33mm) 3081<br />

200 Foot Coil<br />

1/16" (1.59mm) 0.010" (0.25mm) 30832<br />

1/16" (1.59mm) 0.020" (0.51mm) 31312<br />

*Minimum tubing order is 3ft<br />

© Copyright 2004 Alltech Associates, Inc.<br />

PTFE (Tetrafluoroethylene) Tubing<br />

TFE (TETRAFLUOROETHYLENE) TUBING<br />

O.D. I.D. LENGTH PART NO. PRICE<br />

1/16" (1.59mm) 0.038" (0.96mm) per ft † 31321<br />

1/16" (1.59mm) 0.038" (0.96mm) per meter † 31323<br />

1/16" (1.59mm) 0.038" (0.96mm) 50 ft 3132<br />

1/8" (3.18mm) 0.098" (2.49mm) per ft* 31341<br />

1/8" (3.18mm) 0.098" (2.49mm) per meter † 31343<br />

1/8" (3.18mm) 0.098" (2.49mm) 50 ft 3134<br />

1/4" (6.35mm) 0.125" (3.17mm) per ft* 31361<br />

1/4" (6.35mm) 0.125" (3.17mm) per meter † 31363<br />

1/4" (6.35mm) 0.125" (3.17mm) 50 ft 3136<br />

*6ft minimum †2m minimum<br />

Polypropylene/Polyethylene Tubing<br />

POLYPROPYLENE/POLYETHYLENE TUBING<br />

O.D. I.D. TYPE LENGTH PART NO. PRICE<br />

1/8" (3.18mm) 0.080" (2.03mm) PP 50 ft 3203<br />

1/8" (3.18mm) 0.080" (2.03mm) PP 100 ft 3201<br />

1/4" (6.35mm) 0.125" (3.17mm) PE 50 ft 3207<br />

1/4" (6.35mm) 0.125" (3.17mm) PE 100 ft 3205<br />

Need Fittings?<br />

See pages 417-421 for a complete<br />

selection of <strong>GC</strong> fittings.<br />

For PEEK and other HPLC tubing, refer to pages<br />

230-235. For fused silica tubing, see page 386.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Tubing<br />

Tubing Cutters<br />

Plastic Tubing Shear<br />

• Cuts all types of plastic tubing<br />

• Stainless steel blade makes clean, square cuts<br />

• Compact - only 3" Long<br />

PLASTIC TUBING SHEAR<br />

DESCRIPTION QTY PART NO. PRICE<br />

Plastic Tubing Shear ea 3206<br />

Replacement Blade ea 3214<br />

5376<br />

Rotary Tubing Cutter<br />

• Cuts 1/32" to 1/8" o.d. tubing<br />

• Leaves tubing i.d. open<br />

• Cuts metal and glass-lined tubing<br />

• No deburring or ream ing necessary<br />

ROTARY TUBING CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Rotary Tubing Cutter ea 3165<br />

Replacement Cutting Wheels 3 3167<br />

5110<br />

Clean-Cut Tubing Cutter<br />

• Cuts PTFE, Tefzel ® , Polyolefin, PEEK<br />

• Make clean, square cuts without<br />

deforming i.d.s<br />

CLEAN-CUT TUBING CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Clean-Cut Tubing Cutter ea 35902<br />

Replacement Blade ea 35903<br />

Plier-Type Tubing Cutter<br />

• Cuts 1/16" o.d. tubing<br />

• Ideal for cutting tubing in tight places<br />

PLIER-TYPE TUBING CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Plier-Type Tubing Cutter ea 3169<br />

Cutting Kit For 1/16" Tubing<br />

• Knife file and rig for scoring<br />

the tubing to a preset depth<br />

• Scoring provides a clean and<br />

even break<br />

• Stops are provided for 0.010", 0.020" and<br />

0.030" i.d. tubing<br />

CUTTING KIT FOR 1/16" TUBING<br />

DESCRIPTION QTY PART NO. PRICE<br />

Cutting Kit ea 7180<br />

Replacement Knife File ea 7181<br />

5377<br />

3306<br />

5111<br />

Imp Tubing Cutter<br />

• Cuts SS, copper, nickel, & aluminum tubing<br />

• Ideal for tight spaces<br />

• Requires only 1-3/4" swing radius<br />

IMP TUBING CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Imp Tubing Cutter ea 3208<br />

Replacement Cutting Wheels 5 320210<br />

Imperial Tubing Cutter<br />

• Cuts 1/8" to 1-1/8" o.d. tubing<br />

• Makes clean, right-angle cuts with no<br />

burring<br />

• Includes spare cutting wheel<br />

IMPERIAL TUBING CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Imperial Tubing Cutter ea 3210<br />

Replacement Cutting Wheels 2 3212<br />

Heavy-Duty Cutting Wheels 3 13984<br />

Heavy-Duty Tubing Cutter<br />

• Cuts stainless steel, copper,<br />

nickel, and aluminum tubing<br />

• Cuts 1/8" to 1-1/8" o.d.<br />

tubing<br />

HEAVY-DUTY TUBING CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Heavy-Duty Tubing Cutter ea 13995<br />

Replacement Cutting Wheels 3 13981<br />

5113<br />

5114<br />

5112<br />

Glass Tubing Cutter<br />

Glass Knife Cutter<br />

• Makes glass cutting a snap<br />

• More accurate than a file<br />

3314<br />

• Cuts capillary fused silica<br />

and glass tubing of all sizes.<br />

• Includes a double edged<br />

tungsten carbide blade.<br />

0033<br />

GLASS TUBING CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Glass Tubing Cutter ea 3150<br />

Replacement Cutting Wheels 3 3150CW<br />

© Copyright 2004 Alltech Associates, Inc.<br />

GLASS KNIFE CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Glass Knife Cutter ea 5600<br />

Replacement Blade ea 5601<br />

Contact your Alltech office or distributor for current or local prices.<br />

425


Tubing<br />

A C C E S S O R I E S<br />

Tubing Cutters & <strong>Accessories</strong><br />

426<br />

Electric Tubing Cutter<br />

Assure zero dead volume connections<br />

• Clamp vise securely holds tubing in<br />

place<br />

• Cut 1/16", 1/8" and 1/4" o.d.<br />

tubings with i.d.’s as small as<br />

0.008"<br />

• Requires no lubricant or cutting<br />

fluid<br />

This electric tubing cutter assures square and burrfree<br />

cuts for maximum chromatographic performance.<br />

Use the included dressing tool for 1/16" o.d. tubing<br />

to finish the inside and outside diameters of tubing<br />

ends. Dressing tool for 1/8" and 1/4" o.d. tubing and<br />

replacement cutting wheels can be ordered separately<br />

below. Tubing cutter is voltage selectable for 110-120/<br />

220-240 VAC, 50/60 Hz.<br />

Fused Silica Cutter<br />

• Cleanly cut fused silica tubing<br />

• Small enough to keep handy in<br />

your pocket<br />

Tubing Reamers<br />

• Smooth and debur metal tubing ends<br />

• 1/16" reamer set includes inner & outer reamers<br />

• Inner reamers handles most tubing i.d.s<br />

Inner Reamer<br />

Outer Reamer<br />

ELECTRIC TUBING CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Electric Tubing Cutter ea 10-0200<br />

Replacement Part and <strong>Accessories</strong><br />

Dressing tool for 1/8" and 1/4" o.d. Tubing ea 13984<br />

Replacement cutting wheels 3 10-0124<br />

Repl. dressing tool for 1/16" o.d. tubing ea 10-0116<br />

FUSED SILICA CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Fused Silica Cutter 5 3194<br />

TUBING REAMERS<br />

DESCRIPTION QTY PART NO. PRICE<br />

1/16" Reamer Set ea 13974<br />

1/8" Outer Reamer ea 32199<br />

1/4" Outer Remer ea 32219<br />

Inner Reamer for 1/8"-3/8" o.d. ea 32159<br />

© Copyright 2004 Alltech Associates, Inc.<br />

5117<br />

5118<br />

6281<br />

4502<br />

SGT Shortix Capillary Column<br />

Cutter<br />

• Makes perfect fused silica cuts<br />

• Rotating diamond blade precisely<br />

scores capillary columns<br />

• Edges are clean & straight, column<br />

walls are undamaged<br />

• Cuts 100-500µm i.d. capillaries<br />

Capillary Scribers<br />

• Make clean scratches and breaks of fused silica<br />

capillary tubing<br />

• Tungsten carbide tipped marks steel, stainless steel,<br />

and ceramics<br />

• Diamond-tipped marks any surface - even glass<br />

6258 6259<br />

Diamond-Tipped Scriber<br />

Compact Tube Bender<br />

CAPILLARY COLUMN CUTTER<br />

DESCRIPTION QTY PART NO. PRICE<br />

Shortix Column Cutter ea 5190<br />

Replacement Blade ea 5192<br />

CAPILLARY SCRIBERS<br />

DESCRIPTION QTY PART NO. PRICE<br />

Tungsten Carbide Scriber ea 3155<br />

Diamond-tipped Scriber ea 3159<br />

• Bends 1/8", 3/16", 1/4", 3-, 4-,<br />

5-, and 6mm tubing<br />

• Easily bends copper,<br />

aluminum, and thin walled<br />

steel tubing<br />

COMPACT TUBE BENDER<br />

Heavy-Duty Tube Benders<br />

• Bend heavy-walled tubing<br />

with ease<br />

Tungsten Carbide Scriber<br />

DESCRIPTION QTY PART NO. PRICE<br />

Compact Tube Bender ea 3232<br />

HEAVY-DUTY TUBE BENDER<br />

DESCRIPTION QTY PART NO. PRICE<br />

For 1/8" Tubing ea 3220<br />

For 1/4" Tubing ea 3224<br />

Contact your Alltech office or distributor for current or local prices.<br />

5116<br />

5115<br />

4394


A C C E S S O R I E S<br />

Injection Liners<br />

Deactivated Injection Liners<br />

DEACTIVATED INJECTION LINERS<br />

DESCRIPTION AND LENGTH X O.D.<br />

DIAGRAM<br />

Injection Liners for Agilent/Hewlett-Packard Instruments*<br />

Cup Splitter<br />

78.5 x 6.3mm<br />

Split/Splitless with Deactivated Quartz<br />

Wool, 78.5 x 6.3mm o.d., 4mm i.d.<br />

Splitless,<br />

78.5 x 6.3mm o.d., 4mm i.d.<br />

Quartz Splitless,<br />

78.5 x 6.0mm, 2mm i.d.<br />

Recessed Gooseneck with Deactivated<br />

Quartz Wool, 78.5 x 6.3mm, 4mm i.d.<br />

Recessed Gooseneck,<br />

78.5 x 6.3mm, 2mm i.d.<br />

Direct,<br />

78.5 x 6.3mm, 1.5mm i.d.<br />

Injection Liners for Varian Instruments<br />

Splitter with Deactivated Quartz Wool,<br />

1075/1077, 72 x 6.3mm, 4mm i.d.<br />

Frit Splitter, 1075/1077,<br />

72 x 6.3mm, 4mm i.d.<br />

Baffle Splitter, 1075/1077,<br />

72 x 6.3mm, 4mm i.d.<br />

Splitless 1075/1077, 74 x 6.3mm, 2mm<br />

i.d.<br />

0.8mm SPI 1093/1094,<br />

54 x 4.6mm<br />

0.5mm SPI 1093/1094,<br />

54 x 4.6mm<br />

SPI with Buffer 1093/1094,<br />

54 x 4.6mm<br />

Injection Liners for Perkin-Elmer Instruments<br />

Split/Splitless 8500, 8600,<br />

100 x 5.0mm, 3mm i.d.<br />

Splitless 8500, 8600,<br />

100 x 5.0mm, 2mm i.d.<br />

PTV Liner 8500, 8600,<br />

88 x 2.0mm, 1mm i.d.<br />

Split/Splitless Autosystem,<br />

92 x 5.8mm, 4mm i.d.<br />

Split/Splitless Autosystem,<br />

92 x 5.8mm, 2mm i.d.<br />

Injection Liners for Shimadzu Instruments<br />

Split 17A with Deactivated Quartz<br />

Wool, 95.5 x 5.0mm, 3mm i.d.<br />

Splitless 17A,<br />

95.5 x 5.0mm, 3mm i.d.<br />

Gooseneck/Splitless,<br />

95.5 x 5.0mm, 3mm i.d.<br />

Split 9A, 15A, 16A,<br />

127.5 x 5.0mm, 3mm i.d.<br />

Splitless 9A, 15A, 16A,<br />

127.5 x 5.0mm, 3mm i.d.<br />

Injection Liners for Finnigan Instruments<br />

Splitless 5100 Series,<br />

85 x 6.3mm, 2mm i.d.<br />

Splitless 4100 Series,<br />

112 x 4.5mm, 2mm i.d.<br />

*Also compatible with Varian Model CP-1177 Split/Splitless Injector Port<br />

© Copyright 2004 Alltech Associates, Inc.<br />

EACH<br />

PART NO.<br />

PRICE<br />

5/PK<br />

PART NO.<br />

PRICE<br />

25/PK<br />

PART NO.<br />

4825 4827 4829<br />

4906 4924 4928<br />

4929 4934 4936<br />

4962 4963 4964<br />

4959 4960 4961<br />

4958 4938 4957<br />

4967 4968 4969<br />

4970 4971 4972<br />

4973 4974 4975<br />

4977 4978 4979<br />

4980 4981 4982<br />

4983 4984 4985<br />

4986 4987 4988<br />

4989 4990 4991<br />

4790 4792 4794<br />

4992 4993 4994<br />

4995 4996 4997<br />

4796 4798 4800<br />

4810 4812 4814<br />

4748 4750 4752<br />

4754 4756 4758<br />

4760 4762 4764<br />

4766 4768 4770<br />

4772 4774 4776<br />

4856 4857 4858<br />

4859 4860 4862<br />

PRICE<br />

Contact your Alltech office or distributor for current or local prices.<br />

427


Injection Liners<br />

A C C E S S O R I E S<br />

DEACTIVATED INJECTION LINERS (CONT’D)<br />

DESCRIPTION AND LENGTH X O.D.<br />

Injection Liners for Carlo Erba-Fisons Instruments<br />

Split/Splitless 6000 Series with Deactivated<br />

Quartz Wool, 79.5 x 5.0mm, 3mm i.d.<br />

Splitless 6000 Series, 79.5 x 5.0mm, 4mm<br />

i.d.<br />

Splitless 6000 Series, 79.5 x 5.0mm, 2mm<br />

i.d.<br />

DIAGRAM<br />

EACH<br />

PART NO.<br />

PRICE<br />

5/PK<br />

PART NO.<br />

PRICE<br />

25/PK<br />

PART NO.<br />

4742 4744 4746<br />

4853 4854 4855<br />

4998 4851 4852<br />

Split 8000 Series, 105 x 8.0mm, 3mm i.d. 4784 4786 4788<br />

PRICE<br />

Deactivated SGE FocusLiners<br />

DESCRIPTION AND LENGTH X O.D.<br />

DEACTIVATED SGE FOCUSLINERS<br />

DIAGRAM<br />

5/PK<br />

PART NO.<br />

PRICE<br />

25/PK<br />

PART NO.<br />

for Agilent/Hewlett Packard Instruments*<br />

FocusLiner, 78.5 x 6.3 x 4mm i.d. 85474 85480<br />

PRICE<br />

Tapered FocusLiner, 78.5 x 6.3 x 4mm i.d. 85481 85574<br />

FAST FocusLiner, 78.5 x 6.3 x 2.3mm i.d. 85605 85606<br />

Tapered FAST FocusLiner,<br />

78.5 x 6.3 x 2.3mm i.d.<br />

85607 — —<br />

for Varian Injector Models 1075/1077<br />

FocusLiner, 72 x 6.3 x 4mm i.d. 85477 — —<br />

Tapered FocusLiner, 74 x 6.3 x 4mm i.d. 85484 — —<br />

FocusLiner w/Top Restriction,<br />

85633 — —<br />

72 x 6.3 x 4mm i.d.<br />

FAST FocusLiner, 72 x 6.3 x 2.3mm i.d. 85634 — —<br />

for Varian Injector Models 1078/1079<br />

FocusLiner, 54 x 5 x 3.4mm i.d. 85437 — —<br />

Tapered FocusLiner, 54 x 5 x 3.4mm i.d. 85635 — —<br />

for Shimadzu 17A<br />

FocusLiner, 95 x 5 x 3.4mm i.d. 85476 — —<br />

Tapered FocusLiner, 95 x 5 x 3.4mm i.d. 85483 — —<br />

for Shimadzu 14/15A/16<br />

FocusLiner, 99 x 5 x 3.4mm i.d. 85608 — —<br />

Tapered FocusLiner, 99 x 5 x 3.4mm i.d. 85630 — —<br />

for Perkin Elmer Autosystem<br />

FocusLiner, 92 x 6.2 x 4mm i.d. 85478 — —<br />

Tapered FocusLiner, 92 x 6.2 x 4mm i.d. 85482 — —<br />

for ThermoQuest Model 8000/TRACE<br />

FocusLiner, 105 x 8 x 5mm i.d. 85631 — —<br />

Tapered FocusLiner, 105 x 8 x 5mm i.d. 85632 — —<br />

* Also compatible with Varian model CP-1177 Split/Splitless injection port.<br />

428<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.


A C C E S S O R I E S<br />

Injector <strong>Accessories</strong><br />

<strong>GC</strong> O-rings<br />

• Thermally Stable<br />

• No Bleed<br />

• Suitable for <strong>GC</strong>/MS<br />

Graphite O-rings may replace the Viton ® or silicone<br />

O-rings normally used to seal the Agilent 5890 Split and<br />

Splitless injection liners. Splitless liners have an internal<br />

diameter of 6.5mm and split liners have an internal<br />

diameter of 6.35mm.<br />

Specifications<br />

PROPERTY GRAPHITE SILICONE PTFE VITON ®<br />

Max. Temp. 450°C 230°C 230°C 200°C<br />

Chem. Rest. Good Good Superb Superb<br />

Durability Superb Moderate Superb Good<br />

Bleed None Medium Low Low<br />

Color Black Red White Black<br />

O-RINGS<br />

SIZE QTY. PART NO. PRICE<br />

Graphite <strong>GC</strong> O-rings (450°C Limit)<br />

1/4" (6.5mm i.d.) 10 7160<br />

1/4" (6.35mm i.d.) 10 7176<br />

Silicone O-rings (230°C Limit)<br />

1/8" 100 7020<br />

3/16" 100 7021<br />

1/4" 100 7022<br />

PTFE O-rings (230°C Limit)<br />

1/8" 100 7023<br />

3/16" 100 7024<br />

1/4" 100 7025<br />

Viton ® O-rings (200°C Limit)<br />

1/8" 100 7017<br />

3/16" 100 7018<br />

1/4" 100 7019<br />

Graphite Washer (450°C Limit)<br />

1/4" i.d. x 7/16" o.d., 1/32" Thick 10 7165<br />

Don't Forget Septa!<br />

See pages 431-433 for a complete selection of septa.<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Injector Supplies for<br />

HP/Agilent 5890/6890 <strong>GC</strong>s<br />

Inlet Seals for HP/Agilent 5890/6890 <strong>GC</strong>s are<br />

available either stainless steel (similar to HP/<br />

Agilent part no. 18740-20880)<br />

or gold plated (similar to<br />

HP/Agilent part no. 18740-<br />

20885). Washers are included<br />

with the inlet seals.<br />

The Reducing Nut for HP/Agilent 5890/6890 <strong>GC</strong>s is<br />

made from stainless steel and is similar to HP/Agilent<br />

part no. 18740-20800.<br />

INJECTOR SUPPLIES FOR HP/AGILENT 5890/6890 <strong>GC</strong>S<br />

DESCRIPTION QTY PART NO. PRICE<br />

Inlet Seal, stainless steel (0.8mm hole)<br />

Inlet Seal, gold plated (0.8mm hole)<br />

Reducing Nut Replacement for HP 5890/<br />

6890<br />

1 15146<br />

10 151461<br />

25 151462<br />

1 15147<br />

10 151471<br />

25 151472<br />

1 15145<br />

Washers, stainless steel (0.375"o.d.) 10 15148<br />

MSD Source Nut, brass 1 15104<br />

<strong>Accessories</strong> for<br />

HP/Agilent &<br />

Varian Capillary Systems<br />

HP/Agilent nuts are available in both standard and<br />

“deep well” versions, with either standard wrench flats<br />

or knurled for easy wrench-free fingertight connections.<br />

The deep well nuts have 2.4mm deep ferrule wells<br />

to accommodate standard capillary ferrules, and the<br />

standard type has a 1.65mm deep ferrule well for HPtype<br />

capillary ferrules.<br />

ACCESSORIES FOR HP/AGILENT AND VARIAN<br />

DESCRIPTION QTY PART NO. PRICE<br />

Capillary Nuts<br />

Capillary Nuts for Varian 2 154740<br />

Capillary Nuts for HP/Agilent 2 154780<br />

Wrench-Free Capillary Nuts for HP/Agilent 2 154785<br />

Deep Well Capillary Nuts for HP/Agilent 2 154781<br />

Wrench-Free Deep Well for HP/Agilent 2 154782<br />

Graphite Ferrules for HP/Agilent<br />

Graphite Ferrules, 0.5mm Hole* 10 1547901<br />

Graphite Ferrules, 1.0mm Hole** 10 1548001<br />

Wrench<br />

5/16" x 1/4" Open-End Wrench ea 1998<br />

* for 0.25 and 0.32mm i.d. Capillary Column.<br />

** for 0.45 and 0.53mm i.d. Capillary Column.<br />

Contact your Alltech office or distributor for current or local prices.<br />

6650<br />

6651<br />

429


Kits<br />

A C C E S S O R I E S<br />

430<br />

Alltech<br />

Maintenance<br />

Kit for<br />

HP/Agilent <strong>GC</strong>’s<br />

• Easily maintain the injector and FID<br />

• For use with HP/Agilent 5890 and 6890 <strong>GC</strong>’s<br />

Your results rely on the performance of your <strong>GC</strong>. The<br />

Maintenance Kit for HP/Agilent <strong>GC</strong>’s contains all the<br />

supplies you need to perform routine maintenance and<br />

trouble-shooting on your injector and FID.<br />

Kit Includes:<br />

For Column Installation<br />

• 2 - HP style capillary nuts<br />

• 10 - 0.5mm HP style graphite ferrules<br />

• 10 - 1.0mm HP style graphite ferrules<br />

For Injector Maintenance & Troubleshooting<br />

• 5 - split/splitless liner with deactivated quartz wool,<br />

4mm i.d.<br />

• 5 - splitless liner, 4mm i.d.<br />

• 100 - 1/4" Viton o-rings<br />

• 10 -1/4" graphite ferrules<br />

• 25 - 9.5mm ThermoRed septa<br />

• 2 - 0.8mm stainless steel inlet seals<br />

For Detector Maintenance & Troubleshooting<br />

• 40 - 1' lengths redi cut wire (10 each 0.003", 0.005",<br />

0.010", & 0.020" o.d.)<br />

• 4 - stainless steel tube brushes<br />

ALLTECH’S MAINTENANCE KIT FOR HP/AGILENT <strong>GC</strong>’S<br />

DESCRIPTION PART NO. PRICE<br />

Alltech Answer Maintenance Kit 20814<br />

Have a Question about Your Order?<br />

For other Alltech Kits, including the EPA Method 552.1<br />

for Haloacetic Acids in Water Kit, and the USP Method<br />

467 Kits, request data sheet 20830.<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact Alltech Customer Service:<br />

Online Ordering 24 hours a day:<br />

www.alltechWEB.com<br />

Email: alltech@alltechemail.com<br />

5828<br />

Alltech <strong>GC</strong><br />

Start-Up Kit<br />

• Convenient<br />

• Suitable for use with any capillary <strong>GC</strong><br />

Kit contains the necessary tools to set up and operate<br />

your <strong>GC</strong>. Alltech’s <strong>GC</strong> Start Up Kit includes all the<br />

supplies you need to install columns, set gas flows, set<br />

linear velocity, and perform routine maintenance on your<br />

<strong>GC</strong>.<br />

Kit includes:<br />

For General Maintenance<br />

• 4 - open-end wrenches (2 each, 7/16" x 1/2" & 9/16"<br />

x 5/8")<br />

• 1 - 2-way reversible screwdriver<br />

• 25 - 9.5mm and 11mm ThermoRed septa<br />

• 1 - septa puller<br />

• 4 - stainless steel tube brushes<br />

• 40 - 1' lengths redi-cut wire<br />

(10 of each diameter - 0.003", 0.005", 0.010" &<br />

0.020" o.d.)<br />

• 8oz. - leak-check soapfilm solution<br />

For Column Installation<br />

• 2 - open-end wrenches (1/4" x 5/16")<br />

• 1 - scriber for cutting fused silica tubing<br />

• 1 pair - PTFE coated forceps<br />

• 1 - Pick (for removing ferrules from fittings)<br />

• 1 - laminated ruler<br />

• 10' length - high temperature string<br />

• 1 - 20X magnifier (for checking ends of tubing)<br />

• 2' length - pipecleaner (for cleaning liners)<br />

• 10 - 1/16" to 0.4mm, 0.5mm, and 0.8mm graphite<br />

ferrules<br />

For Setting Gas Flows<br />

• 1 - 100cc soapfilm flow meter<br />

• 10' length - 5/16" Tygon tubing<br />

• 1 - stopwatch<br />

For Setting Linear Velocity<br />

• 1- Hamilton 1701 and 701 Gastight Syringe with<br />

Removable needle and 3 replacement needles<br />

• 1 - 14L Scotty II 99.99% methane standard<br />

• 1 - Scotty II syringe adapter<br />

ALLTECH’S <strong>GC</strong> START UP KIT<br />

DESCRIPTION PART NO. PRICE<br />

Alltech Answer <strong>GC</strong> Start Up Kit 20810<br />

Contact your Alltech office or distributor for current or local prices.<br />

3967


A C C E S S O R I E S<br />

Septa<br />

How to select a septum for your<br />

application<br />

Specifications<br />

ACTUAL SIZE DRAWING MEASUREMENT CHROMATOGRAPH<br />

4610<br />

With so many septa to choose from, choosing a<br />

septum for your application can be a confusing task.<br />

There are a number of criteria you need to consider<br />

when selecting a septum.<br />

1. Make and Model of Gas Chromatograph –<br />

This will determine what size of septum you need.<br />

Alltech carries a full range of septum sizes to fit<br />

most gas chromatographs.<br />

2. Performance – A high performance, low bleed<br />

septum is desirable so that septa bleed does not<br />

interfere with the chromatography of your sample.<br />

Keep in mind that all septa bleed to some extent.<br />

The amount of bleed visible to the detector is<br />

affected by several factors which include:<br />

- The composition and pretreatment of the<br />

septum material.<br />

- The sensitivity setting of the detector<br />

amplifier.<br />

- The type of detector.<br />

- The injection port setting.<br />

- Isothermal or temperature programming.<br />

- The type of injection (direct, splitless,<br />

split, etc.)<br />

Choose a high performance septum such as<br />

Alltech’s ThermoRed or XLB septa to minimize septa<br />

bleed.<br />

3. Injection Port Temperature - The temperature<br />

of the septum never reaches the injection port<br />

temperature setting. The center of the injector<br />

heated zone, where the sample is deposited,<br />

is regulated to correspond to the injector port<br />

setting. Be sure to select a septum with a maximum<br />

temperature that exceeds your injection port<br />

temperature.<br />

4. Penetration/Resealing Qualities - Ideally,<br />

you want a septum that is soft and easily<br />

penetrated by a syringe needle and has excellent<br />

resealing properties. This will prevent you from<br />

bending syringe needles and coring of the septum<br />

to give you longer septum life. Excellent resealing<br />

properties will prevent leaks that might adversely<br />

affect your chromatography or damage your<br />

analytical column.<br />

Septa Selection Guide<br />

PRODUCT MAX. TEMP. COLOR DUROMETER* LOW BLEED<br />

Thermo Red 300°C Red 50-55 Excellent<br />

XLB 350°C Green 50-55 Excellent<br />

HT-X High<br />

Performance<br />

350°C Blue 50-60 Excellent<br />

General Purpose<br />

White<br />

250°C White 40-45 Very Good<br />

Standard Blue 300°C Blue 55-60 Very Good<br />

General Purpose<br />

Blue<br />

250°C Blue 40-45 Good<br />

Cylindrical Half<br />

Hole<br />

250°C Blue 50-55 Very Good<br />

Cylindrical 3-layer 200°C Red 50-55 Excellent<br />

Three Layer 300°C<br />

Red/<br />

White<br />

50-55 Good<br />

Four Layer 225°C<br />

Microsep<br />

PTFE-lined<br />

Microsep Low<br />

bleed PTFE-lined<br />

1/4"(6mm)<br />

3/8"<br />

(9.5mm)<br />

7/16"<br />

(11mm)<br />

1/2"<br />

(12.5mm)<br />

21/32"<br />

(17mm)<br />

* Use cylindrical plug septa, see page 432.<br />

250°C<br />

250°C<br />

Shimadzu*, SRI*<br />

Antek, Finnigan 9100, 9600,<br />

Gow-Mac, Agilent 5700, 5880<br />

& 5900, IBM, Packard 427-433,<br />

Pye-Unicam (early models),<br />

Varian (except capillary inj.),<br />

Tracor 550, 560.<br />

Carle, Agilent 5890,6850,6890.<br />

P-E Sigma, 900, 990, 3920,<br />

8300, 8400, 8500 Autosys,<br />

Varian (capillary injector), SPI,<br />

Varian 1078/1079<br />

Fisons/Carlo Erba, Finnigan<br />

9500, HP/Agilent 5750 and<br />

earlier models, Packard 409-<br />

421, Tracor 220, 222, 540.<br />

Fisons/Carlo Erba 8000 Series,<br />

CE TRACE <strong>GC</strong><br />

Red/<br />

White<br />

Off<br />

White<br />

Yellow/<br />

Off<br />

White<br />

50-55 Good<br />

25-35 Good<br />

25-35 Very Good<br />

* Durometer - Harness of the silicone material. The lower the number, the<br />

softer the material.<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

431


Septa<br />

A C C E S S O R I E S<br />

Septa<br />

General Purpose Blue Septa<br />

• Maximum temperature of 250°C<br />

(300°C for short periods)<br />

• Lifetime of up to 150 injections<br />

• Suitable for most <strong>GC</strong> analysis<br />

4603<br />

XLB Septa<br />

• Maximum temperature to 350°C<br />

• Extremely low bleed<br />

• Superior resealing properties<br />

• Soft, easily penetrated by syringe needle<br />

4607<br />

GENERAL PURPOSE BLUE SEPTA<br />

SIZE (O.D.) QTY PART NO. PRICE<br />

1/4" (6mm) 100 6512<br />

1/4" (6mm) 10 x 100 65122<br />

3/8" (9.5mm) 100 6514<br />

3/8" (9.5mm) 10 x 100 65142<br />

7/16" (11mm) 100 6518<br />

7/16" (11mm) 10 x 100 65182<br />

1/2" (12.5mm) 100 6520<br />

1/2" (12.5mm) 10 x 100 65202<br />

12" x 12" Sheet ea 6528<br />

XLB SEPTA<br />

SIZE (O.D.) QTY PART NO. PRICE<br />

1/4" (6mm) 50 15427<br />

3/8" (9.5mm) 50 15428<br />

7/16" (11mm) 50 15429<br />

1/2" (12.5mm) 50 15430<br />

21/32" (17mm) 50 15039<br />

General Purpose White Septa<br />

• Maximum temperature of 250°C<br />

• Lifetime of over 100 injections<br />

• Designed for use in 90% of all <strong>GC</strong> analysis<br />

4605<br />

HT-X High Performance Septa<br />

• Maximum temperature of 350°C<br />

• Long injection life - over 200 injections<br />

4604<br />

432<br />

GENERAL PURPOSE WHITE SEPTA<br />

SIZE (O.D.) QTY PART NO. PRICE<br />

3/8" (9.5mm) 50 7812<br />

3/8" (9.5mm) 2 x 50 78101<br />

7/16" (11mm) 50 7813<br />

7/16" (11mm) 2 x 50 78111<br />

1/2" (12.5mm) 50 7816<br />

1/2" (12.5mm) 2 x 50 78141<br />

ThermoRed Septa<br />

• Maximum temperature of 300°C<br />

• Packed in glass jars under strict QC<br />

standards to protect from contaminants<br />

THERMORED SEPTA<br />

SIZE (O.D.) QTY PART NO. PRICE<br />

11/32'' (9mm) 25 15129<br />

3/8'' (9.5mm) 25 15131<br />

7/16'' (11mm) 25 15132<br />

1/2" (12.5mm) 25 15141<br />

21/32'' (17mm) 25 15133<br />

Plug Type (For Shimadzu & SRI) 25 15134<br />

Standard Blue Septa<br />

• Maximum temperature of 300°C<br />

• Lifetime of over 50 injections<br />

STANDARD BLUE SEPTA<br />

SIZE (O.D.) QTY PART NO. PRICE<br />

3/8" (9.5mm) 100 7824<br />

7/16" (11mm) 100 7826<br />

1/2" (12.5mm) 100 7830<br />

© Copyright 2004 Alltech Associates, Inc.<br />

4608<br />

4601<br />

HT-X HIGH PERFORMANCE SEPTA<br />

SIZE (O.D.) QTY PART NO. PRICE<br />

1/4" (6mm) 50 15490<br />

5/16" (8mm) 50 15491<br />

3/8" (9.5mm) 50 15492<br />

7/16" (11mm) 50 15493<br />

21/32" (17mm) 50 154941<br />

1/2" (12.5mm) 50 15494<br />

12" x 12" Sheet ea 15496<br />

Plug Type (For Shimadzu & SRI) 50 15498<br />

Cylindrical Septa<br />

• 8mm Long x 6mm o.d.<br />

with half-hole<br />

The standard half-hole septa is red silicone with an<br />

upper temperature limit of 225°C. 3-layer septa features<br />

the shielding and reinforcing properties of PTFE. The<br />

plug septa are low bleed, have an upper temperature<br />

limit of 350°C, and are compatible with Shimadzu and<br />

SRI.<br />

CYLINDRICAL SEPTA<br />

SIZE (O.D.) QTY PART NO. PRICE<br />

Cylindrical Half-Hole Septa<br />

1/4" (6mm) 25 6524<br />

1/4" (6mm) 4 x 25 6526<br />

3 Layer 1/4" (6mm) 50 9602<br />

Cylindrical Plug Septa for<br />

Shimadzu and SRI<br />

50 15498<br />

Contact your Alltech office or distributor for current or local prices.<br />

4597<br />

Half-Hole Septa Shown Here


G C A C C E S S O R I E S<br />

Septa<br />

Septa<br />

Three- and Four-Layer Septa<br />

• Excellent sealing characteristics<br />

• Maximum temperature of 300ºC (3-layer) and 225ºC<br />

(4-layer)<br />

The Three-Layer Septa consists of a layer of red<br />

silicone rubber, a layer of translucent soft silicone rubber<br />

and another layer of red silicone rubber. The Four-Layer<br />

Septa is the same but with a 10-mil (0.010") PTFE<br />

facing.<br />

Microsep ® PTFE-Lined Septa<br />

• Maximum temperature of 250ºC<br />

• Off-white silicone rubber with an ivory PTFE backing<br />

4593<br />

3-Layer Septa<br />

4595 4594<br />

THREE- AND FOUR-LAYER SEPTA<br />

Hamilton Three-Layer Septa<br />

• Maximum temperature of 200ºC<br />

4-Layer Septa<br />

SIZE (O.D.) QTY. PART NO. PRICE<br />

Three-Layer Septa<br />

3/8" (9.5mm) 100 7836<br />

7/16" (11mm) 100 7838<br />

1/2" (12.5mm) 100 7840<br />

Four-Layer Septa<br />

3/8" (9.5mm) 100 7844<br />

7/16" (11mm) 100 7846<br />

1/2" (12.5mm) 100 7848<br />

These septa feature a center layer of soft silicone<br />

rubber for good resealing and two harder rubber outer<br />

layers for long life. The soft inner layer clings to the<br />

syringe needle and returns quickly to its original shape<br />

when the needle is withdrawn to prevent “blow back”.<br />

MICROSEP ® PTFE-LINED SEPTA<br />

SIZE (O.D.) QTY. PART NO. PRICE<br />

0.250" (6mm) 12 75801<br />

0.250" (6mm) 100 79391<br />

0.281" (7mm) 12 75810<br />

0.355" (9mm) 12 75803<br />

0.375" (9.5mm) 12 75804<br />

0.375" (9.5mm) 100 79411<br />

0.394" (10mm) 12 75805<br />

0.394" (10mm) 100 79451<br />

0.438" (11mm) 12 75807<br />

0.438" (11mm) 100 79471<br />

0.469" (12mm) 12 75813<br />

0.500" (12.5mm) 12 75806<br />

0.500" (12.5mm) 100 79491<br />

Microsep ® Low-Bleed PTFE-Lined Septa<br />

• Maximum temperature of 250ºC<br />

• Off-white silicone septa with yellow PTFE backing<br />

4591<br />

HAMILTON THREE-LAYER SEPTA<br />

SIZE (O.D.) QTY. PART NO. PRICE<br />

0.197" (5mm) 12 76022<br />

0.250" (6.35mm) 12 76001<br />

0.281" (7mm) 12 76010<br />

0.312" (8mm) 12 76002<br />

0.355" (9.0mm) 12 76003<br />

0.375" (9.5mm) 12 76004<br />

0.394" (10.0mm) 12 76005<br />

0.438" (11mm) 12 76007<br />

0.469" (12mm) 12 76013<br />

0.500" (12.7mm) 12 76006<br />

0.594" (15mm) 12 76016<br />

0.750" (19.0mm) 12 76020<br />

© Copyright 2004 Alltech Associates, Inc.<br />

4596<br />

MICROSEP ® LOW-BLEED PTFE-LINED SEPTA<br />

SIZE (O.D.) QTY. PART NO. PRICE<br />

3/8" (9.5mm) 50 7802<br />

3/8" (9.5mm) 2 x 50 78001<br />

3/8" (9.5mm) 20 x 50 78002<br />

7/16" (11mm) 50 7803<br />

7/16" (11mm) 2 x 50 78011<br />

7/16" (11mm) 20 x 50 78012<br />

1/2" (12.5mm) 50 7806<br />

1/2" (12.5mm) 2 x 50 78041<br />

1/2" (12.5mm) 20 x 50 78042<br />

Contact your Alltech office or distributor for current or local prices.<br />

433


Septa<br />

G C A C C E S S O R I E S<br />

434<br />

JADE Mechanical Inlet<br />

Injection Kits<br />

• Models available to accommodate 39 different inlets<br />

from 16 different manufacturers<br />

• No need to modify your existing <strong>GC</strong><br />

• Temperature limit up to 400°C set point (with Hi-<br />

Temp Needle Guide)<br />

• Cost effective and reliable<br />

© Copyright 2004 Alltech Associates, Inc.<br />

2808 2809<br />

The JADE Mechanical Inlet works like a miniature<br />

airlock. First, the syringe needle passes through a<br />

needle guide forming an annular seal. Next, the needle<br />

guide encounters the ball-and-seat valve, unseats the<br />

ball, and enters the injection port. When the needle is<br />

removed from the ball valve, a powerful return magnet<br />

pulls the ball back onto the seat, sealing the injection<br />

port.<br />

The elegantly simple ball-and-seat is the system’s<br />

most technologically complex component. For the<br />

utmost in reliability, it uses sophisticated materials<br />

and close tolerances found in the most advanced<br />

instrumentation.<br />

The JADE Inlet’s long lifetime, heat resistance, and<br />

low-maintenance design make it the obvious solution<br />

for autosampling. After the JADE Inlet is installed,<br />

there’s minimal need for operator attention, enabling<br />

chromatographers to focus on more important tasks<br />

instead of monitoring septum failure.<br />

Ultimately, the JADE Inlet serves as a vital link<br />

in implementing online <strong>GC</strong> applications where system<br />

longevity, reliability, and low maintenance are absolute<br />

requirements.<br />

Each JADE Inlet Kit Includes:<br />

- JADE Inlet Injector (complete with needle guide)<br />

- Adapter for <strong>GC</strong> inlet with gasket(s)<br />

- Extra needle guide<br />

- Spare gasket for adapter<br />

- Two 10µL syringes for sample injection<br />

- “BAKE-OUT” plug for cleaning inlet before installation<br />

- Complete instructions<br />

JADE MECHANICAL INLET INJECTION KITS<br />

0.47MM<br />

PART NO.<br />

0.63MM<br />

PART NO.<br />

HP/Agilent<br />

5830/5840 9774 9788<br />

5880/5890/6890 Split/Splitless 9764 9778<br />

5880/5890/6890 Packed 9762 9776<br />

5710/5790 Packed 9774 9788<br />

5700 Capillary 9764 9778<br />

5993 <strong>GC</strong>/MS 9764 9778<br />

5890 Purged/Packed 9909 9683<br />

Cool/On-Column (0.53mm i.d.) 9755 —<br />

HP/Agilent Autosamplers*<br />

7673A&B Split/Splitless — 9925<br />

7673A&B Packed — 9927<br />

7673A&B Purged/Packed — 9198<br />

Carlo-Erba (Except TRACE 2000) 9750 9752<br />

Chrompack 9774 9788<br />

Dani (All Models) 9754 9756<br />

Dionex (602D) 8850 8852<br />

Finnigan (9610/9611 Series) 9751 9753<br />

Fisons (Series 8000) 9033 9178<br />

Gow-Mac (All Models) 9774 9788<br />

HNU Systems (3000 Series) 9774 9788<br />

Konik (HR<strong>GC</strong> 3000C) 9774 9788<br />

Perkin Elmer*<br />

2000/8300/8700/8500 Sigma Series 9774 9788<br />

Shimadzu<br />

8/9/14A and 15A Packed 9738 9732<br />

14A and 15A Split/Splitless 9736 9730<br />

17A Split/Splitless 7268 8014<br />

Siemens<br />

Temp. Programmed Injector 9735 9737<br />

SRI (Split & Packed) 8858 8860<br />

Tracor/Tremetrics<br />

540/570 Series 9739 9747<br />

560/565 Series 8950 8984<br />

9000 Series 9959 9962<br />

ThermoQuest<br />

Trace <strong>GC</strong> 7258 7260<br />

<strong>GC</strong>Q 7189 7196<br />

Varian**<br />

1040 Packed 9748 9734<br />

1075/1077/1078/1079 Split/Splitless 9768 9786<br />

1075/1077/1078/1079 Split/Splitless 9193 9195<br />

with Trigger<br />

1085 9197 9199<br />

1093/1094 SPI Injector with Trigger 9689 9699<br />

1400/2400/2700 Series 9921 9923<br />

3400/3700 Capillary, 1cm Septum 9768 9786<br />

3400/3700 Capillary, 8mm Septum 9748 9734<br />

3300 Capillary 9768 9786<br />

Universal<br />

7/16" x 20 Swagelok ® Thread 9774 9788<br />

Econo Kit † — 97505<br />

* JADE Inlet is incompatible with HP 6890 autosamplers and Perkin Elmer<br />

autosampler.<br />

**JADE Inlets are compatible with Varian Star autosamplers, but may be<br />

incompatible with other Varian models.<br />

†<br />

Includes inlet body, green cap and 0.63mm needle guide. Adapter nut not<br />

included.<br />

JADE Inlets are also available for SPME.<br />

Request datasheet 9778.<br />

PRICE<br />

Contact your Alltech office or distributor for current or local prices.


G C A C C E S S O R I E S<br />

Septa<br />

The JADE Mechanical Inlet<br />

Installing a JADE Inlet*<br />

Precision-made,<br />

tapered needle<br />

guide<br />

Durable hard<br />

anodized finish<br />

1 2<br />

Ball magnet<br />

return<br />

High precision<br />

balls provide<br />

perfect sealing<br />

US. Patent #5,062,310<br />

Replacement Parts<br />

Ball seat<br />

No-bleed high<br />

temperature<br />

gasket seals off<br />

<strong>GC</strong> port<br />

6252<br />

2208<br />

After removal of the<br />

septum nut and septum,<br />

clean out old septum<br />

particles. A polyimide<br />

gasket (included) is placed<br />

in the septum well.<br />

3 4<br />

2209<br />

The adapter nut is threaded<br />

on to the injection port<br />

finger tight.<br />

DESCRIPTION<br />

REPLACEMENT JADE INLET NEEDLE GUIDES<br />

REPLACEMENT JADE INLET GASKETS<br />

DESCRIPTION QTY. PART NO. PRICE<br />

HP/Agilent<br />

Cool/On-Column 2 9688<br />

5830/5840/5880/5890/6890 2 9763<br />

HP/Agilent Autosamplers<br />

5880/5890 and 7673A&B Capillary 2 9759<br />

5880/5890 and 7673A&B Packed 2 9761<br />

Carlo Erba 2 9666<br />

Dani 2 9684<br />

Finnigan 9610/9611 2 9686<br />

Fisons 8000 2 7911<br />

Gow Mac 2 9763<br />

Packard 2 9763<br />

Perkin Elmer 2000/8300/8500/8700 2 9763<br />

Shimadzu (all) 2 9789<br />

Siemens<br />

Capillary 2 7989<br />

TP 2 7991<br />

ThermoQuest<br />

Trace <strong>GC</strong> 2 7266<br />

<strong>GC</strong>Q 2 7236<br />

Tracor<br />

540/570 2 7992<br />

560/565 2 7264<br />

9000 2 7993<br />

Varian<br />

1075/1077/1078/1079 2 9795<br />

1040/3400/3700 2 9796<br />

1093/1094 2 7994<br />

1400/2400/2700 2 7996<br />

Universal 2 9763<br />

© Copyright 2004 Alltech Associates, Inc.<br />

0.47MM<br />

PART NO.<br />

0.63MM<br />

PART NO.<br />

Standard, Up to 350°C 9790 9794<br />

Hi-Temp, 250°C - 400°C 9792 9797<br />

PRICE<br />

*Note: The instructions are for installation on a Agilent/Hewlett-Packard<br />

injection port. Installation may vary slightly for other instruments.<br />

2210<br />

A one-time bake-out step<br />

is recommended to remove<br />

residual septum materials<br />

from the injection port.<br />

The brass bake-out plug<br />

(included) is installed on<br />

the adapter nut for this<br />

step. The bake-out plug is<br />

removed when done.<br />

Syringes for JADE Inlets<br />

NEEDLE<br />

TYPE<br />

SYRINGES FOR JADE INLETS<br />

NEEDLE<br />

HAMILTON<br />

PART NO.<br />

Contact your Alltech office or distributor for current or local prices.<br />

2211<br />

The JADE Inlet body is<br />

threaded into the adapter<br />

nut finger tight. With<br />

the appropriate wrench in<br />

place on the adapter nut,<br />

tighten the valve body 1/4<br />

to 1/2 turn using a 1/2"<br />

wrench. The completely<br />

assembled JADE Inlet is<br />

now ready for worry-free<br />

operation.<br />

SGE<br />

PART NO.<br />

VOLUME<br />

O.D.<br />

PRICE<br />

PRICE<br />

Manual Injection Syringes<br />

0.5µL RN 0.63mm 86240 — —<br />

1.0µL RN 0.63mm 801400 85372<br />

1.0µL RN 0.47mm 80141 — —<br />

10µL Fixed 0.63mm 80343 9942<br />

10µL Fixed 0.47mm 80344 85374<br />

Autosampler Syringes HP7673<br />

2.5µL Fixed 0.63mm — — 9658<br />

5.0µL Fixed 0.63mm 87948 85376<br />

5.0µL Fixed 0.47mm — — 85075<br />

5.0µL Fixed 0.63mm — — 85376<br />

5.0µL Fixed 0.47mm — — 85075<br />

4907<br />

435


Septa<br />

G C A C C E S S O R I E S<br />

436<br />

Septa <strong>Accessories</strong><br />

Merlin Microseal Septum<br />

• Lasts for thousands<br />

of injections<br />

• No instrument<br />

modification needed<br />

• Installation as<br />

easy as changing a<br />

standard septum<br />

• High pressure model allows operation up to 100psig<br />

The Merlin Microseal Septum is a long-life<br />

replacement for the septum and septum nut on the<br />

capillary inlet system of an Agilent <strong>GC</strong>. It incorporates<br />

two sequential seals to provide a much longer period of<br />

use between seal changes. Use the Merlin Microseal <br />

with the HP 7673 Autosampler to allow many more<br />

samples to be run unattended while reducing the risk<br />

of lost or compromised data caused by septum leaks<br />

or fragmentation. It also allows for easier manual<br />

injections.<br />

The Microseal Septum lasts longest when a syringe<br />

needle with a truncated cone shaped tip is used. It<br />

may also be used with the standard 0.63mm diameter<br />

(0.026", 23-gauge) needle recommended for use with the<br />

HP 7673 Autosampler.<br />

MERLIN MICROSEAL SEPTUM*<br />

DESCRIPTION PART NO. PRICE<br />

Microseal Septum Kits<br />

For HP/Agilent <strong>GC</strong>s<br />

Microseal Nut and 2 Septa 80060<br />

Microseal Nut and 1 Septum 80062<br />

Microseal High Pressure Septum Kits<br />

Standard Kit, Nut and 2 Septa 80190<br />

Starter Kit, Nut and 1 Septum 80192<br />

For Varian 1078 & 1079 <strong>GC</strong>s with SPME Injector<br />

Varian Kit, Nut with start switch, 1 septum<br />

and o-ring<br />

80031<br />

Replacement Parts<br />

For HP/Agilent <strong>GC</strong>s<br />

Microseal Septum, ea 80063<br />

Microseal High Pressure Septum, ea 80194<br />

Microseal High Pressure Nut, ea 80196<br />

For Varian 1078 & 1079 <strong>GC</strong>s with SPME Injector<br />

Microseal High Pressure Septum, ea 80035<br />

*Regular Merlin Microseal has a 30psig limit. High Pressure Merlin Microseal <br />

has a 100psig limit.<br />

Septum Remover<br />

90º hooked point allows for safe septum removal.<br />

Aluminum body. 8" length.<br />

SEPTUM REMOVER<br />

DESCRIPTION PART NO. PRICE<br />

Septum Remover 24030<br />

© Copyright 2004 Alltech Associates, Inc.<br />

5070<br />

4584<br />

Septa-Out<br />

Safely extract cylindrical septa<br />

without the danger of breaking your<br />

glass column or sampling bulb port.<br />

Heat Resistant Gloves<br />

• Protect your hands from burns<br />

• Heavyweight cotton/Kevlar ®<br />

combination<br />

Knit construction offers superior<br />

comfort and lessens hand fatigue.<br />

Gloves are ambidextrous and feature a<br />

glove-within-a-glove design.<br />

Inlet Pressure Gauge<br />

Insert the needle directly into the inlet<br />

of any gas chromatograph for direct pressure<br />

measurement. The small, 0.028" o.d. needle<br />

permits repeated inlet pressure checks without<br />

damage to the septum.<br />

Septum Needle Guide<br />

SEPTA-OUT<br />

DESCRIPTION PART NO. PRICE<br />

Septa-Out 6412<br />

HEAT RESISTANT GLOVES<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Heat Resistant Gloves pr 2906<br />

INLET PRESSURE GAUGE<br />

DESCRIPTION PART NO. PRICE<br />

0-30psig 86805<br />

0-60psig 86806<br />

0-100psig 86807<br />

0-200psig 86808<br />

Replacement Needle Assembly 18260<br />

This septum needle guide helps<br />

reduce bent syringe needles and<br />

extends septum life. With the<br />

septum needle guide you get double leak protection.<br />

A cylindrical septum acts as a double seal should your<br />

primary septum start leaking. Needle guide is selfcentering<br />

to aid in on-column injection.<br />

SEPTUM NEEDLE GUIDE<br />

DESCRIPTION PART NO. PRICE<br />

Needle Guide, 7/16" x 20 Thread* 6401<br />

Needle Guide, 7/16" x 24 Thread 6403<br />

Needle Guide without Nut 6400<br />

Drill Bit for Enlarging Hole 6402<br />

Replacement Cylindrical Septa, 25/pk 6524<br />

*Fits most injection ports including: PE-3920 and Sigma Series; HP5700, 5800,<br />

and 6900 Series (5890 and 6890).<br />

Contact your Alltech office or distributor for current or local prices.<br />

4585<br />

4582<br />

4588<br />

4583


G C A C C E S S O R I E S<br />

Organizers and Tools<br />

Organizers and Tools<br />

<strong>GC</strong> Column and Accessory Organizers<br />

Keep all your high-use columns readily available and<br />

protected with these 5-column or 10-column storage<br />

units. Both units feature a covered 7-bin, small-parts<br />

storage on top. Larger tools can be stored in the tool<br />

holder on the side. Columns are easy to remove and ID<br />

tags are readily visible.<br />

5-Column Organizer<br />

14L x 13H x 10.5"W<br />

(35.5L x 33H x 26.5cmW)<br />

5688 5687<br />

10-Column Organizer<br />

25L x 12.75H x 10.5"W<br />

(63.5L x 32H x 26.5cmW)<br />

Organizer Box<br />

These organizers are ideal<br />

for storing small parts such as<br />

septa, ferrules, and fittings.<br />

The 9-compartment organizer<br />

includes eight 1-3/8" x 1-5/8"<br />

slots and one 1-1/8" x 3-1/4"<br />

slot. The 18-compartment<br />

organizer includes twelve 2" x 2" slots<br />

and six 2" x 4-3/16" slots.<br />

Capillary Magnifiers<br />

ORGANIZER BOX<br />

DESCRIPTION PART NO. PRICE<br />

9-Compartment Box 6264<br />

18-Compartment Box 6266<br />

These magnifiers are ideal for inspecting the ends<br />

of capillary columns. The lighted magnifier includes a<br />

battery.<br />

5772<br />

<strong>GC</strong> COLUMN AND ACCESSORY ORGANIZERS<br />

DESCRIPTION PART NO. PRICE<br />

<strong>GC</strong> Column Organizer, 5-Column 6390<br />

<strong>GC</strong> Column Organizer, 10-Column 6392<br />

20X Magnifier<br />

5325 2156<br />

Lighted Magnifying Glass<br />

Drawer Organizer<br />

This compact organizer<br />

features 30 drawers for storing<br />

all of your small parts and<br />

accessories. Clear plastic drawers<br />

are 1-1/8"L x 2"W x 4-5/8"D<br />

and can be easily labeled.<br />

Overall organizer dimensions are<br />

8-1/4"L x 11-1/4"W x 5-1/8"D.<br />

5270<br />

Gas Torch<br />

CAPILLARY MAGNIFIERS<br />

DESCRIPTION PART NO. PRICE<br />

20X Magnifier 3163<br />

Lighted Magnifier 3196<br />

Ideal for sealing the ends of capillary<br />

columns. Basic kit contains the torch, two<br />

Micronox cylinders, one butane cylinder,<br />

three silver soldering rods, flux tube, two<br />

flame tips and complete instructions.<br />

5181<br />

Adjustable Organizer<br />

DRAWER ORGANIZER<br />

DESCRIPTION PART NO. PRICE<br />

Drawer Organizer 6260<br />

This extra-large organizer<br />

has 14 adjustable dividers<br />

and 4 shelves for convenient<br />

access to common lab supplies.<br />

PVC construction is chemically<br />

resistant and makes cleaning<br />

easy. 20"H x 24"W x 10.5"D<br />

ADJUSTABLE ORGANIZER<br />

DESCRIPTION PART NO. PRICE<br />

Adjustable Organizer 5242<br />

© Copyright 2004 Alltech Associates, Inc.<br />

5509<br />

Heat Gun<br />

GAS TORCH<br />

DESCRIPTION PART NO. PRICE<br />

Basic Torch Kit 14600<br />

Cylinder Kit (4 Micronox and 2 Butane) 14601<br />

Micronox Cylinders, 6/pk 14602<br />

Butane Cylinders, 6/pk 14603<br />

Piercing Knob, Butane 14604<br />

Piercing Knob, Micronox 14605<br />

Ideal for heating polyimide<br />

sealing resin when connecting<br />

capillaries and guard columns. Gun<br />

heats to 350ºC, features a 3-position<br />

switch (off/cool/hot) and includes an adjustable stand.<br />

HEAT GUN<br />

DESCRIPTION PART NO. PRICE<br />

120VAC, 4.5A, 60Hz 2518<br />

220VAC, 2.0A, 50/60Hz 2518-220V<br />

Contact your Alltech office or distributor for current or local prices.<br />

6691<br />

437


Tools<br />

G C A C C E S S O R I E S<br />

Tools<br />

Capillary Tool Kit<br />

Autoranging Digital Multimeter<br />

Kit includes diamond scriber,<br />

2 open end wrenches, PTFE<br />

coated forceps, ruler, ferrule<br />

pick, 10' high temperature<br />

string, 20X magnifier, and pipe<br />

cleaner.<br />

5179<br />

Unit has a 1/2" 3-3/4 digit LCD.<br />

Measures DCV, ACV, OHM, DC current, AC<br />

current, frequency plus diode check and<br />

continuity test. Uses 1-9V battery.<br />

6779<br />

CAPILLARY TOOL KIT<br />

DESCRIPTION PART NO. PRICE<br />

Capillary Tool Kit 16879<br />

23-Piece Tool Kit in Zippered Case<br />

AUTORANGING DIGITAL MULTIMETER<br />

DESCRIPTION PART NO. PRICE<br />

Autoranging Digital Multimeter 25970<br />

9-Way Cylinder Wrench<br />

Kit includes 7 screwdrivers,<br />

adjustable wrench, 2 pliers,<br />

wire stripper, knife, alignment<br />

tool, stainless rule, hex key set,<br />

scissors, 2 flexible files, burnisher,<br />

miniature soldering iron, solder<br />

aid, coil of solder, and desoldering braid.<br />

5323<br />

9-WAY CYLINDER WRENCH<br />

DESCRIPTION PART NO. PRICE<br />

9-Way Cylinder Wrench 412933<br />

5178<br />

Adjustable Wrench<br />

• Chrome-Plated<br />

Open-End Wrench<br />

• Chrome-Plated<br />

23-PIECE TOOL KIT IN ZIPPERED CASE<br />

DESCRIPTION PART NO. PRICE<br />

23-Piece Tool Kit and Case 16533<br />

ADJUSTABLE WRENCH<br />

DESCRIPTION PART NO. PRICE<br />

4" Long – 1/2" Capacity 16549<br />

6" Long – 3/4" Capacity 3211<br />

8" Long – 7/8" Capacity 16522<br />

OPEN-END WRENCH<br />

DESCRIPTION PART NO. PRICE<br />

1/4" x 5/16" – Fits 1/16" Fitting Nuts 1998<br />

7/16" x 1/2" – Fits 1/8" & 3/16" Fitting Nuts 1999<br />

9/16" x 5/8" – Fits 1/4" & 3/8" Fitting Nuts 2000<br />

5322<br />

5321<br />

Miniature Files, Fine Cut<br />

Set includes six different<br />

shaped, 5-1/2" long files.<br />

They are made of hard chrome<br />

steel suitable for smoothing<br />

and deburring.<br />

Miniature Reamers<br />

Set includes six different sizes:<br />

0.028"/0.018", 0.040"/0.026",<br />

0.048"/0.032", 0.080"/0.050",<br />

0.085"/0.053", 0.104"/0.062".<br />

Flame Checker<br />

Pivoting mirror head fogs<br />

when flame is lit.<br />

MINIATURE FILES<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Miniature Files, Fine Cut 6/pk 7237<br />

MINIATURE REAMERS<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Miniature Reamers 6/pk 7330<br />

6279<br />

5324<br />

438<br />

© Copyright 2004 Alltech Associates, Inc.<br />

FLAME CHECKER<br />

DESCRIPTION PART NO. PRICE<br />

Flame Checker 7047<br />

Contact your Alltech office or distributor for current or local prices.<br />

5715


G C A C C E S S O R I E S<br />

Valves<br />

Flow Control Valves<br />

Valve Selection Guide<br />

Toggle Valves<br />

Ball Valves<br />

Toggle valves are designed<br />

primarily as on-off valves for<br />

low pressure applications (less<br />

than 250 psig). The handle<br />

position provides a quick<br />

verification of the on/off<br />

status.<br />

5228<br />

Ball valves are designed<br />

to throttle or shut off liquid<br />

and gas lines in high pressure<br />

applications (1500-2500psig).<br />

They are available in 2-way or<br />

3-way configurations.<br />

5230<br />

Plug Valves<br />

Plug valves are designed<br />

to throttle or shut off liquid<br />

and gas lines in intermediate<br />

pressure applications (less<br />

than 500 psig). They generally<br />

have a higher temperature<br />

limit than ball or toggle<br />

valves.<br />

5231<br />

Metering Valves<br />

Metering valves are multiturn<br />

valves designed to<br />

regulate gas flow.<br />

For order information on Plug Valves, Ball Valves<br />

and Metering Valves, see page 440.<br />

5238<br />

Parker Toggle Valves<br />

These forged-body valves are<br />

positive, soft-seat shut-off valves<br />

designed for quick opening and<br />

closing. Shut-off force is constant<br />

because of the spring load. The<br />

handle locks in the open or closed<br />

position. A TFE stem tip provides<br />

a leak-tight seal. The maximum<br />

working pressure is 250psig;<br />

Part No. 2328<br />

maximum temperature is 93°C.<br />

They are made of brass or 316 stainless steel with TFE<br />

seat, Viton ® packing and nylon handle. All other parts<br />

are 316 stainless steel.<br />

Hoke Toggle Valves<br />

These valves feature a simple,<br />

reliable, low-maintenance design<br />

that is well suited for a wide<br />

variety of applications. They<br />

are made of brass or stainless<br />

steel and include long-lasting<br />

Viton ® seat and o-ring packing<br />

for positive pressure or vacuum<br />

applications. The maximum<br />

operating pressure is 200psig<br />

and the maximum operating<br />

temperature is 149°C.<br />

5225 5259<br />

Part No. 12131<br />

PARKER TOGGLE VALVES<br />

DESCRIPTION PART NO. PRICE<br />

1/8" Brass 2328<br />

1/4" Brass 2332<br />

1/8" SS 2336<br />

1/4" SS 2340<br />

HOKE TOGGLE VALVES<br />

DESCRIPTION PART NO. PRICE<br />

Straight Toggle Valves<br />

1/8" Brass 12131<br />

1/4" Brass 12133<br />

1/8" SS 12132<br />

1/4" SS 12134<br />

Angled Toggle Valves<br />

1/8" Brass 12135<br />

1/4" Brass 12136<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

439


Valves<br />

G C A C C E S S O R I E S<br />

Flow Control Valves<br />

Nupro and Whitey Plug and Ball Valves<br />

The plug valves are constructed of brass or stainless<br />

steel and TFE. The compact plug valves can be used up<br />

to 3000psig and the temperature limit is 200°C. They<br />

have a plug orifice of 0.172" for high flow capacity.<br />

The 2-way and 3-way ball valves can be used up to<br />

65°C and are pressure-rated to 2500psig. Both can be<br />

panel-mounted in a 19/32" hole. The 1/8" valves have<br />

a 0.093" orifice while the 1/4" valves have a 0.125"<br />

orifice.<br />

Hoke Plug and Ball Valves<br />

The plug valves are constructed of brass or stainless<br />

steel and PTFE. They have an upper pressure limit of<br />

3000psig and an upper temperature limit of 205°C. They<br />

have a plug orifice of 0.093".<br />

The 2-way ball valves are made of brass or stainless<br />

steel and PTFE. They have an upper temperature limit of<br />

179°C and an upper pressure limit of 1500psig. The 1/8"<br />

version has a 0.093" orifice while the 1/4" version has a<br />

0.187".<br />

The 3-way ball valves are made of brass or stainless<br />

steel and PTFE/Nylatron ® . They have an upper pressure<br />

limit of 500psig and an upper temperature limit of<br />

179°C. Both sizes have a 0.187" orifice.<br />

5232 5233 5234<br />

Part No. 14320 Part No. 14318 Part No. 14316<br />

440<br />

DESCRIPTION<br />

NUPRO AND WHITEY PLUG AND BALL VALVES<br />

PLUG<br />

VALVE<br />

PART NO.<br />

PRICE<br />

5235<br />

NUPRO AND WHITEY FINE METERING VALVES<br />

DESCRIPTION PART NO. PRICE<br />

Straight Pattern<br />

1/8", Brass 8600<br />

1/4", Brass 8602<br />

1/8", SS 8604<br />

1/4", SS 8606<br />

Angle Pattern<br />

1/8", Brass 8608<br />

1/4", Brass 8610<br />

1/8", SS 8612<br />

1/4", SS 8614<br />

© Copyright 2004 Alltech Associates, Inc.<br />

2-WAY<br />

BALL VALVE<br />

PART NO.<br />

PRICE<br />

3-WAY<br />

BALL VALVE<br />

PART NO.<br />

1/8", Brass 14320 14318 14316<br />

1/4", Brass 14319 14317 14315<br />

1/8", SS 16013 16017 16022<br />

1/4", SS 16015 16019 16024<br />

Nupro and Whitey Fine Metering Valves<br />

5261<br />

PRICE<br />

These valves give extremely fine control in the 0-<br />

400cc/minute gas flow range. The maximum pressure<br />

rating is 1000psig at 70°C. The maximum temperature<br />

limit for brass valves is 150°C; 200°C for stainless steel.<br />

They can be panel mounted in a 37/64" hole.<br />

Angle<br />

Part No. 8612<br />

5262 5260 5263<br />

Part No. 12126 Part No. 12119 Part No. 12123<br />

DESCRIPTION<br />

PLUG<br />

VALVE<br />

PART NO.<br />

HOKE PLUG AND BALL VALVES<br />

PRICE<br />

2-WAY<br />

BALL VALVE<br />

PART NO.<br />

PRICE<br />

Hoke Fine Metering Valves with Vernier Knob<br />

These valves allow reproducibility<br />

of precise flows. All valves use a TFE<br />

seat seal and packing. Brass valves are<br />

rated at 3000psig; stainless steel at<br />

5000psig. Temperatures up to 230°C<br />

can be used but at lower pressures.<br />

HOKE FINE METERING VALVES<br />

3-WAY<br />

BALL VALVE<br />

PART NO.<br />

1/8", Brass 12126 12118 12122<br />

1/4", Brass 12128 12120 12124<br />

1/8", SS 12127 12119 12123<br />

1/4", SS 12129 12121 12125<br />

Plug Valve Repair Kit 12130<br />

Straight<br />

Part No. 8604 Part No. 86001<br />

DESCRIPTION PART NO. PRICE<br />

Straight Pattern<br />

1/8", Brass 86001<br />

1/4", Brass 86021<br />

1/8", SS 86041<br />

1/4", SS 86061<br />

Angle Pattern<br />

1/8", Brass 86081<br />

1/4", Brass 86101<br />

1/8", SS 86121<br />

1/4", SS 86141<br />

PRICE<br />

Contact your Alltech office or distributor for current or local prices.<br />

5264


G C A C C E S S O R I E S<br />

Valves<br />

Alltech <strong>GC</strong>/MS Switching Valve<br />

Switch Between Columns with the Turn of a Valve<br />

• Replace columns<br />

without <strong>GC</strong>/MS<br />

shutdown<br />

• Protect and maintain<br />

flow path integrity<br />

• Compatible with any<br />

<strong>GC</strong>/MS system<br />

• Installs quickly and<br />

easily<br />

Alltech’s <strong>GC</strong>/MS<br />

6239<br />

switching valve<br />

eliminates long downtimes associated with column<br />

changes. Use the valve as a bypass valve to supply<br />

continuous carrier gas to the MS while changing a<br />

column in a single injector system or to switch between<br />

two columns from two injection ports to one MS.<br />

The <strong>GC</strong>/MS switching valve is easy to install. Simply<br />

place the valve directly in the <strong>GC</strong> oven, connect the<br />

capillary columns and transfer lines to the appropriately<br />

labeled ports and the valve is ready to use.<br />

<strong>GC</strong>/MS Switching Valve Specifications<br />

Temperature Range: Ambient to 350°C<br />

Maximum Pressure:<br />

25psig<br />

Connections:<br />

Zero Dead Volume<br />

Compatible Column Sizes: 0.25mm or 0.32mm i.d.<br />

<strong>GC</strong>/MS SWITCHING VALVE<br />

DESCRIPTION QTY. PART NO. PRICE<br />

<strong>GC</strong>/MS Switching Valve<br />

For 0.25mm i.d. ea 12325<br />

For 0.32mm i.d. ea 12327<br />

Replacement Parts<br />

Nuts, 1/32" 5 12317<br />

0.25mm Ferrule & Liner Set 5 12319<br />

0.32mm Ferrule & Liner Set 5 12324<br />

For more information on the <strong>GC</strong>/MS Switching Valve,<br />

request IS037. Also available on our website.<br />

SGE ms-NoVent Valve<br />

Prevents Air and Water from Entering the MS during Column Changeover<br />

• Simple operation<br />

• Direct <strong>GC</strong>/MS<br />

interface<br />

• Save 6-12 hours<br />

The ms-NoVent is<br />

a fluidic valve that can<br />

be retrofitted to any <strong>GC</strong><br />

mass spectrometer. It<br />

5689<br />

allows column changeover without the need to vent the<br />

MS resulting in a time saving of 6-12 hours. The unique<br />

design ensures a helium purge maintains a positive flow<br />

from the valve, to the atmosphere, when a column is not<br />

connected. Certain <strong>GC</strong>/MS models require a restrictor to<br />

be ordered separately at right.<br />

SGE MS-NOVENT <br />

DESCRIPTION PART NO. PRICE<br />

ms-NoVent <br />

Suitable for Varian, Shimadzu, Perkin-Elmer,<br />

ThermoQuest, and HP/Agilent (all HP models<br />

including 5890 and 6890)<br />

113400<br />

ms-NoVent Restrictors<br />

Restrictor for HP5970 113405<br />

Restrictor for HP5971/5972 113407<br />

Restrictor for HP5973 113409<br />

Restrictor and Adapter for Varian Saturn 2000 113412<br />

Restrictor and Adapter for Shimadzu 5000/5050 113410<br />

Need Technical Assistance?<br />

Call Alltech Tech Support:<br />

Email: tech_service@alltechemail.com<br />

Online: www.alltechWEB.com<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.<br />

441


Valves<br />

G C A C C E S S O R I E S<br />

Valco ® Sampling/Switching Valves<br />

Zero Volume Fittings Allow for Direct Valve Connections<br />

• Easily adapt to any type of tubing<br />

• Eliminate pressure surges during sample injections<br />

• Carefully leak tested<br />

Valco ® sampling/switching valves are ideal for all <strong>GC</strong><br />

sample injections and flow switching applications. The<br />

low internal volume and uniform flow paths eliminate<br />

peak broadening and loss of resolution. Medium<br />

temperature valves have a limit of 175ºC and high<br />

temperature valves have a limit of 300ºC. Valves require<br />

sample loops—order separately on facing page.<br />

Valco ® valves feature zero volume fittings that allow<br />

tubing connections to the valve body without increasing<br />

the internal sample volume. Fittings also make direct,<br />

on-column injections possible. Replacement zero volume<br />

fittings are available on facing page.<br />

What’s included: zero-volume fittings, mounting<br />

bracket, and handle.<br />

4678<br />

Valco ® Sampling/Switching Valve Specifications<br />

Valve Body: Type 316 Stainless Steel Max. Temp: 175°C for medium temperature valves<br />

300°C for high temperature valves*<br />

Valve Seal: Carbon-filled PTFE (Medium Temp.) or<br />

Carbon-filled Polyimide (High Temp.)<br />

Active Ports: 3,4,6,8 or 10 Ports (Note: a 10-port valve can be used<br />

as a 6- or 8-port valve)<br />

Outlet Fitting:<br />

Max. Pressure:<br />

1/16" zero-volume fittings or<br />

1/8" zero-volume fittings (included)<br />

400psig<br />

Mounting: Valves supplied with angle mounting brackets for<br />

mounting on the side of the instruments or they can<br />

be flush mounted. Valves are tapped with 8-32TPI<br />

holes. Most <strong>GC</strong>s are designed to accept these valves.<br />

*Cannot be used below 200°C.<br />

VALCO ® SAMPLING/SWITCHING VALVES*<br />

DIAGRAM PORTS FITTINGS<br />

MEDIUM TEMP.<br />

VALVE PART NO.<br />

PRICE<br />

HIGH TEMP.<br />

VALVE PART NO.<br />

PRICE<br />

REPL. SHAFT & SEAL<br />

FOR MEDIUM TEMP.<br />

VALVE PART NO.<br />

PRICE<br />

0345<br />

3-Port 1/16" Zero Volume 9099 39099 290990<br />

1/8" Zero Volume 9101 39101 291010<br />

0346<br />

4-Port 1/16" Zero Volume 9103 39103 29103<br />

1/8" Zero Volume 9104 39104 29104<br />

2102<br />

6-Port 1/16" Zero Volume 9105 39105 29105<br />

1/8" Zero Volume 9110 39110 29110<br />

2103<br />

8-Port 1/16" Zero Volume 9115 39115 29115<br />

1/8" Zero Volume 9116 39116 29116<br />

2104<br />

10-Port 1/16" Zero Volume 9119 39119 29119<br />

1/8" Zero Volume 9120 39120 291200<br />

* By special order, valves can be fabricated from Hastalloy C ® . Call for pricing information.<br />

442<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.


G C A C C E S S O R I E S<br />

Valves<br />

<strong>Accessories</strong> for Valco ® Sampling/Switching Valves<br />

Stainless Steel Sample Loops<br />

Zero Volume Fittings<br />

LOOP SIZE<br />

VALCO ® SS SAMPLE LOOPS*<br />

USE WITH<br />

1/16" VALVES<br />

PART NO.<br />

PRICE<br />

USE WITH<br />

1/8" VALVES<br />

PART NO.<br />

15µL 91056 91106<br />

25µL 91057 91107<br />

50µL 91058 91108<br />

100µL 91059 91109<br />

250µL 91050 91100<br />

500µL 91051 91101<br />

1.0mL 91052 91102<br />

2.0mL 91053 91103<br />

5.0mL 91054 91104<br />

10.0mL 91055 91105<br />

*One pair of nuts and ferrules are included.<br />

Valve Actuators<br />

PRICE<br />

The Valco ® 2-position helical actuators permit the<br />

application of controlled, constant torque for the<br />

actuation of rotary devices. Minimum actuation pressure<br />

is typically less than 30psig for operation of Valco ®<br />

sample injection and switching valves. Low internal<br />

leakage permits either pulsed or continuous operation<br />

with low gas consumption.<br />

Actuators are designed for room temperature<br />

operation, but high temperature versions are also<br />

available. Valves intended for mounting in ovens<br />

or heated detector zones are used with a stand-off<br />

assembly which locates the actuator out of the heated<br />

zone and supports both valve and actuator. Order a<br />

stand-off assembly separately below.<br />

Column<br />

Inlet<br />

DESCRIPTION<br />

Valve Body<br />

Adapter<br />

Valve Body<br />

ZERO VOLUME FITTINGS<br />

USE WITH<br />

1/16" VALVES<br />

PART NO.<br />

Adapters Shown in a Valve<br />

Slot<br />

.010" Orifice (.25mm)<br />

PRICE<br />

Sample<br />

Loop<br />

Fused Silica Tubing<br />

Nut<br />

Polyimide<br />

Ferrule<br />

Rotor<br />

USE WITH<br />

1/8" VALVES<br />

PART NO.<br />

Nuts, 5/pk 458015 458025<br />

Ferrules, 5/pk 458125 458155<br />

Fused Silica Adapters<br />

Fused silica adapters permit easy use of capillary<br />

columns with 1/16" Valco ® valves.<br />

Removable<br />

Polyimide<br />

Liner<br />

1577<br />

PRICE<br />

1578<br />

VALVE ACTUATORS<br />

DESCRIPTION PART NO. PRICE<br />

Air Actuators<br />

90° Air Actuator for 3-8 Port Valves and<br />

3,000psig HPLC Valve<br />

60° Air Actuator for 10 Port Valves and<br />

7,000psig HPLC Valve<br />

90° Hi-Temp Air Actuator for 3-8 Port and<br />

3,000psig HPLC Valves<br />

© Copyright 2004 Alltech Associates, Inc.<br />

9121<br />

9122<br />

91211<br />

Air Switch for Air Actuators, 110V 9123<br />

Air Switch for Air Actuators, 220V 9124<br />

DVI-Digital Valve Interface 1391<br />

6" Stand-Off Assembly 91216<br />

<br />

<br />

<br />

<br />

<br />

FUSED SILICA ADAPTERS<br />

<br />

DESCRIPTION PART NO. PRICE<br />

Fused Silica Adapter for:<br />

0.53mm i.d. Column 1538<br />

0.32mm i.d. Column 1567<br />

0.25mm i.d. Column 1569<br />

Replacement Liner for:<br />

0.53mm i.d. Column, 2/pk 1539<br />

0.32mm i.d. Column, 2/pk 1571<br />

0.25mm i.d. Column, 2/pk 1573<br />

Counter-bored Nut, 2/pk 1549<br />

Replacement Ferrule, 2/pk 1558<br />

Contact your Alltech office or distributor for current or local prices.<br />

1579<br />

443