A C C E S S O R I E S<br />
Capillary <strong>Accessories</strong><br />
Capillary Connectors<br />
Universal Capillary Connectors<br />
• One size fits tubing from 0.25mm i.d. to 0.53mm i.d.<br />
• Available in straight or Y configurations<br />
Capillary connectors form a gas-tight seal when<br />
heated to typical <strong>GC</strong> temperatures. The angled<br />
connectors conform to the curvature of a fused silica<br />
capillary column. To create a permanent seal, add a<br />
small amount of polyimide resin to the outside of the<br />
capillary tube before inserting. Order under "<strong>Accessories</strong>"<br />
below.<br />
Universal Straight Connector<br />
CONNECTORS<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Straight Connectors<br />
Fused Silica<br />
Universal Straight Connector 5 20400<br />
Universal Straight Connector 25 20401<br />
Angled Universal Connector 5 20694<br />
Angled Universal Connector 25 20695<br />
Borosilicate<br />
Universal Straight Connector 5 20490<br />
Universal Straight Connector 25 20492<br />
Y-Connectors<br />
Fused Silica<br />
Universal Y-Connector 1 20405<br />
Angled Universal Y-Connector 1 20500<br />
Borosilicate<br />
Universal Y-Connector 1 20480<br />
Universal Y-Connector 5 20482<br />
<strong>Accessories</strong><br />
Polyimide Sealing Resin 5g 5825<br />
0017<br />
Featherweight Capillary Union<br />
• Lightweight<br />
• High temperature Vespel ®<br />
construction<br />
• Accommodates all tubing sizes<br />
FEATHERWEIGHT CAPILLARY UNION<br />
DESCRIPTION PART NO. PRICE<br />
Featherweight Union with 2 Nuts* 28990<br />
Vespel ® Ferrules for Use with Featherweight Union<br />
Vespel ® Ferrule, 0.8mm i.d. 28992<br />
Vespel ® Ferrule, 0.5mm i.d. 28993<br />
Vespel ® Ferrule, 0.4mm i.d. 28994<br />
*Order ferrules separately.<br />
Fused Silica Outlet Splitters<br />
• Accommodates capillaries<br />
from 0.22 to 0.32mm i.d.<br />
and provides a 1:1 ratio<br />
• Includes a glass-lined SS<br />
bulkhead union, a 0.4mm<br />
6628<br />
i.d. two-hole Vespel ®<br />
graphite ferrule and two lengths of deactivated fused<br />
silica tubing<br />
Use this inert outlet splitter with two detectors or<br />
one detector and a sample collection device.<br />
OUTLET SPLITTER<br />
DESCRIPTION PART NO. PRICE<br />
Outlet Splitter 14898<br />
5717<br />
Valco ® Zero-Dead Volume Union<br />
Use these stainless steel unions to make connections with fused silica<br />
capillaries. Unions feature specially designed Vespel ® /graphite ferrules and<br />
are bored through. Table 1 shows the parts needed for different connections.<br />
6021<br />
Table 1<br />
CONNECT FROM: TO 0.25MM I.D. FUSED SILICA TO 0.32MM I.D. FUSED SILICA TO 0.53MM I.D. FUSED SILICA TO 1/16” SS TUBING<br />
0.25mm i.d. Fused Silica 9068 9068 + 907110 45849 + 907010 + 903410 45849 + 907010<br />
0.32mm i.d. Fused Silica 9069 + 907010 9069 45849 + 907110 + 903410 45849 + 907110<br />
0.53mm i.d. Fused Silica 45849 + 907010 + 903410 45849 + 907110 + 903410 9031 45835 + 903410<br />
1/16" SS Tubing 45849 + 907010 45849 + 907110 45835 + 903410 45835<br />
VALCO ® ZERO-DEAD VOLUME UNIONS<br />
DESCRIPTION AND VALCO ® NO. PART NO. PRICE<br />
Zero Dead-Volume Unions<br />
1/32", 0.4mm (Valco ® ZU.5TFS.4) 9068<br />
1/32", 0.5mm (Valco ® ZU.5TFS.5) 9069<br />
1/16", 0.8mm (Valco ® ZU1TFS.8) 9031<br />
1/16" - 1/32", 1/32" Bore (Valco ® ZRU1.5T) 45849*<br />
1/16", 1/16" Bore (Valco ® ZU1T) 45835*<br />
© Copyright 2004 Alltech Associates, Inc.<br />
VALCO ® REDUCING FERRULES<br />
DESCRIPTION AND VALCO ® NO. PART NO. PRICE<br />
Valco ® Reducing Ferrules<br />
1/32" to 0.4mm (Valco ® FS.4), 10/pk 907010<br />
1/32" to 0.5mm (Valco ® FS.5), 10/pk 907110<br />
1/16" to 0.8mm (Valco ® FS1.8), 10/pk 903410<br />
* Includes 2 stainless steel ferrules.<br />
Contact your Alltech office or distributor for current or local prices.<br />
385
Capillary <strong>Accessories</strong><br />
A C C E S S O R I E S<br />
Capillary Guards & Tubing<br />
386<br />
Universal Guard Column Kits<br />
• Universal kits connect to any capillary column<br />
• Guard columns are<br />
deactivated<br />
Universal guard<br />
column kits contain<br />
three - 5m deactivated<br />
capillaries, three-universal fused silica connectors,<br />
ceramic cutter, and instructions. Order sealing resin<br />
separately under “<strong>Accessories</strong>” to reinforce connections.<br />
Replacement kit parts are available below.<br />
UNIVERSAL GUARD COLUMN KITS<br />
DESCRIPTION PART NO. PRICE<br />
Universal Guard Column Kits<br />
0.53mm Universal Guard Column Kit 13992<br />
0.32mm Universal Guard Column Kit 13998<br />
0.25mm Universal Guard Column Kit 14005<br />
Replacement Parts<br />
Universal Connectors, 5/pk 20400<br />
Angled Universal Connector, 5/pk 20694<br />
5m x 0.53mm i.d. Capillaries, 5/pk 13990<br />
5m x 0.32mm i.d. Capillaries, 5/pk 13999<br />
5m x 0.25mm i.d. Capillaries, 5/pk 14007<br />
<strong>Accessories</strong><br />
Polyimide Sealing Resin, 5g 5825<br />
20X Magnifier 3163<br />
Deactivated Guard Columns<br />
• Three different deactivation polarities<br />
• Chemically inert<br />
These guard columns<br />
protect your analytical column<br />
by collecting non-volatile,<br />
pyrolyzable, or particulate<br />
contamination.<br />
DEACTIVATED GUARD COLUMNS<br />
DESCRIPTION PART NO. PRICE<br />
Non-Polar<br />
0.25mm x 5m 19063<br />
0.32mm x 5m 19064<br />
0.53mm x 5m 19065<br />
Intermediate Polar<br />
0.25mm x 5m 19054<br />
0.32mm x 5m 19055<br />
0.53mm x 5m 19056<br />
Polar<br />
0.25mm x 5m 19057<br />
0.32mm x 5m 19058<br />
0.53mm x 5m 19059<br />
© Copyright 2004 Alltech Associates, Inc.<br />
6630<br />
6624<br />
Fused Silica Capillary Tubing<br />
• Deactivated and undeactivated tubing available<br />
• Available mounted on a cage<br />
Alltech provides the<br />
finest quality fused<br />
silica capillary tubing<br />
either untreated or<br />
deactivated by our<br />
proprietary high<br />
temperature process.<br />
Use tubing to prepare<br />
your own capillaries or<br />
guard columns.<br />
FUSED SILICA CAPILLARY TUBING<br />
I.D. QTY. LENGTH PART NO. PRICE<br />
Deactivated Tubing with Cage<br />
0.18mm — 10m 602026<br />
0.18mm — 20m 602028<br />
0.18mm — 40m 602029<br />
0.25mm — 15m 602915<br />
0.25mm — 30m 602930<br />
0.25mm — 60m 602960<br />
0.32mm — 15m 603915<br />
0.32mm — 30m 603930<br />
0.32mm — 60m 603960<br />
0.45mm — 15m 602030<br />
0.45mm — 30m 602032<br />
0.45mm — 60m 602034<br />
0.53mm — 15m 605915<br />
0.53mm — 30m 605930<br />
0.53mm — 60m 605960<br />
Deactivated Tubing, Without Cage<br />
0.05mm per meter 602038<br />
0.10mm — per meter 602037<br />
0.18mm — per meter 602010<br />
0.25mm — per meter 602640<br />
0.25mm x 1m 5/pk — 5827<br />
0.25mm x 2m 5/pk — 5829<br />
0.32mm — per meter 603640<br />
0.32mm x 1m 5/pk — 5831<br />
0.32mm x 2m 5/pk — 5833<br />
0.45mm — per meter 602012<br />
0.53mm — per meter 605640<br />
0.53mm x 1m 5/pk — 5832<br />
0.53mm x 2m 5/pk — 5834<br />
Undeactivated Tubing, Without Cage<br />
0.05mm — per meter 602035<br />
0.10mm — per meter 602036<br />
0.18mm — per meter 19603<br />
0.25mm — per meter 602600<br />
0.32mm — per meter 603600<br />
0.45mm — per meter 19602<br />
0.53mm — per meter 605600<br />
Contact your Alltech office or distributor for current or local prices.<br />
6631
A C C E S S O R I E S<br />
Capillary <strong>Accessories</strong><br />
Capillary <strong>Accessories</strong><br />
Capillary Cages<br />
These cages are made of a<br />
heavy gauge stainless steel and are<br />
electropolished to prevent abrasion.<br />
All are 7 inches in diameter.<br />
CAPILLARY CAGES<br />
DESCRIPTION PART NO. PRICE<br />
7" x 3/4" Cage 75200<br />
7" x 1-1/4" Cage 75201<br />
7" x 1-3/4" Cage 75202<br />
High Temperature String, 10ft 6344<br />
Capillary Column Washer<br />
This easy to use column washer is designed<br />
for solvent flushing of bonded or crosslinked<br />
fused silica capillaries. It is made of<br />
heavy duty glass and will hold up to 20mL of<br />
solvent. Maximum pressure is 125psig. Order<br />
appropriate sized ferrules separately below.<br />
CAPILLARY COLUMN WASHER<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Capillary Column Washer ea 5819<br />
Ferrules<br />
1/8" to 0.4mm VG1 10 200/0.4-VG1<br />
1/8" to 0.5mm VG1 10 200/0.5-VG1<br />
1/8" to 0.8mm VG1 10 200/0.8-VG1<br />
For a listing of suitable solvents for various<br />
stationary phases, request Data Sheet 5819.<br />
5715<br />
5719<br />
Capillary Endcaps<br />
Increase column life by preventing<br />
contaminants from entering column<br />
during storage.<br />
CAPILLARY ENDCAPS<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Fused Silica 2 20699<br />
Fused Silica 20 20701<br />
Silicone 10 4018<br />
Split-Vent Trap Kit<br />
• Charcoal filter cartridges are<br />
economical and easy to replace<br />
• Adsorbs toxic vapors<br />
• Connects directly to Agilent <strong>GC</strong>’s<br />
Alltech’s split-vent trap kit effectively adsorbs<br />
toxic or noxious vapors that might otherwise be<br />
released into the workplace. The trap has a 1/8"<br />
fitting to connect directly to Agilent <strong>GC</strong>’s and can<br />
be adapted for use with most other <strong>GC</strong>’s.<br />
The split-vent trap features a corrosionresistant<br />
base and a disposable NIOSH-type<br />
charcoal filter cartridge that is easy to replace.<br />
Order replacement cartridges below.<br />
What’s included: split-vent trap, three<br />
charcoal cartridges, cartridge scorer, and tip<br />
breaker.<br />
SPLIT-VENT TRAP KIT<br />
DESCRIPTION PART NO. PRICE<br />
Split-Vent Trap Kit 5870<br />
Replacement Charcoal Cartridge, 10/pk 5872<br />
1/8" Stainless Steel Union 14165<br />
5702<br />
6632<br />
How much solvent is needed to wash your column? Refer to the table below.<br />
Approximate Column Volume Required<br />
LENGTH 0.25MM I.D. 0.32MM I.D. 0.53MM I.D.<br />
10m 0.5mL 0.8mL 2.2mL<br />
15m 0.7mL 1.2mL 3.3mL<br />
25m 1.2mL 2.0mL 5.5mL<br />
30m 1.5mL 2.4mL 6.6mL<br />
50m 2.5mL 4.0mL 11.0mL<br />
60m 2.9mL 4.8mL 13.2mL<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
387
Packed <strong>Accessories</strong><br />
A C C E S S O R I E S<br />
388<br />
Packing <strong>Accessories</strong><br />
Air/Vacuum Pump<br />
• Oil-less operation<br />
• Portable and reliable<br />
This compact rotary vane<br />
air/vacuum pump will deliver 1<br />
liter per minute of oil free air<br />
at 15psig. It features graphite<br />
5083<br />
vanes and sealed-for-life ball bearings. The maximum<br />
vacuum is 20" (508mm) Hg continuous. Pump measures<br />
6-7/16" H x 5-5/8" W x 12" L (163.51mm H x 142.88mm<br />
W x 304.8mm L) and weighs 10lbs (4.54kg).<br />
What’s included: muffler, filter, 1/4" MPT ports, 10ft<br />
power cord with US standard plug.<br />
AIR/VACUUM PUMP<br />
DESCRIPTION PART NO. PRICE<br />
Air/Vacuum Pump, 115V 1531<br />
<strong>Accessories</strong><br />
Pressure Relief Valve 1534<br />
Vacuum Gauge 1536<br />
Pressure Gauge 1537<br />
Nalgene Vacuum Tubing, 1/4" i.d. x 5/8" o.d., 5ft 1599<br />
Attachable Funnel<br />
This anodized aluminum funnel<br />
attaches easily to 1/8" and 1/4" o.d.<br />
glass and metal tubing—ideal for column<br />
packing. Funnel can be disassembled<br />
for cleaning. Order adapters separately<br />
to attach funnel to columns with fittings<br />
already connected. Replacement o-rings are<br />
also available below.<br />
<strong>GC</strong> Column Vibrator<br />
ATTACHABLE FUNNEL<br />
DESCRIPTION PART NO. PRICE<br />
Attachable Funnel 4008<br />
Adapters<br />
for 1/8" Column 4050<br />
for 3/16" Column 4052<br />
for 1/4" Column 4054<br />
for 3/8" Column 4056<br />
Replacement O-rings, 12/pk 4010<br />
This vibrator is ideal for use when filling<br />
<strong>GC</strong> columns, including glass columns. This<br />
two-speed unit comes supplied with a 7-foot<br />
cord and US standard plug.<br />
<strong>GC</strong> COLUMN VIBRATOR<br />
DESCRIPTION PART NO. PRICE<br />
110V 4012<br />
© Copyright 2004 Alltech Associates, Inc.<br />
5079<br />
6660<br />
Premium Glass Wool<br />
Untreated - A soft fine denier Pyrex <br />
wool, primarily used for non-chromatographic<br />
applications.<br />
Silane Treated - Fine wool treated with dimethyldichlorosilane<br />
(DMDCS) to yield an inert material<br />
that won't decompose sensitive compounds. This<br />
material is ideal for most chromatographic applications.<br />
Phosphoric Acid (H3PO4), Treated - For analysis<br />
of acidic compounds such as free acids, phenols and<br />
glycols.<br />
Quartz Wool - Made from high-purity quartz,<br />
extremely low in metallic oxide impurities.<br />
PTFE Wool - Commonly used as a plug for packed<br />
columns when analyzing for low levels of sulfur.<br />
Pesticide Grade Glass Wool - A superbly inert glass<br />
wool ideal for use with electron capture, nitrogenphosphorous,<br />
flame photometric, alkali-bead flame and<br />
all electrolytic detectors.<br />
Glass Wool Tools<br />
Glass Wool Inserter/ Remover<br />
Wool Inserter<br />
PREMIUM GLASS WOOL<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Glass Wool<br />
Untreated Glass Wool 50g 4035<br />
Silane Treated Glass Wool 50g 4037<br />
Silane Treated Glass Wool 250g 4038<br />
H3PO4 Treated Glass Wool 25g 4039<br />
Quartz Wool 10g 4033<br />
Silane Treated Quartz Wool 10g 4233<br />
PTFE Wool 10g 4736<br />
Pesticide Grade Glass Wool 10g 4034<br />
Glass Wool Tools<br />
Glass Wool Inserter/Remover 2 6292<br />
Wool Inserter ea 6285<br />
Delrin ® Plugs<br />
• Use these plugs to seal the ends of<br />
columns<br />
Simply slip plug into your ferrule and<br />
nut, and attach to your fittings. Ferrules<br />
will not lock in place. Plugs are reusable.<br />
DELRIN ® PLUGS<br />
SIZE QTY. PART NO. PRICE<br />
1/16" 25 2898<br />
1/8" 25 2900<br />
1/4" 25 2902<br />
Contact your Alltech office or distributor for current or local prices.<br />
5075<br />
5088<br />
5089<br />
5087
A C C E S S O R I E S<br />
Packed <strong>Accessories</strong><br />
Packing <strong>Accessories</strong><br />
<strong>GC</strong> End Caps<br />
These end caps are nonshredding,<br />
flexible, and easily applied<br />
5085<br />
and removed. They provide a positive barrier to<br />
moisture and air. The 5/16" size fits over 1/4" columns<br />
that have ferrules swaged on the ends. The 3/16" size<br />
fits 1/8" columns with ferrules in place.<br />
<strong>GC</strong> END CAPS<br />
TUBE O.D. QTY. PART NO. PRICE<br />
1/16" 100 4020<br />
1/8" 100 4021<br />
3/16" 100 4022<br />
1/4" 100 4023<br />
5/16" 100 4025<br />
3/8" 100 4024<br />
1/2" 100 4026<br />
Glass Column Repair Kits<br />
This repair kit includes a 1ft<br />
(30.5cm) piece of shrinkable TFE-FEP<br />
tubing that encapsulates the broken<br />
section creating a tight and reliable<br />
seal.<br />
Easy to apply, just slip over one end<br />
of the broken tubes, butt the tubes,<br />
and heat to 330°C with a heat gun.<br />
GLASS COLUMN REPAIR KITS<br />
TUBING SIZE PART NO. PRICE<br />
Glass Column Repair Kits<br />
Up to 0.036" (0.91mm) 5800<br />
Up to 0.060" (1.52mm) 5801<br />
Up to 0.130" (3.30mm) 5802<br />
0.125" (3.18mm) to 0.250" (6.35mm) 5803<br />
Heat Gun<br />
110V 2518<br />
220V 2518-220V<br />
Column Tags<br />
Use these aluminum tags to create<br />
a permanent heat resistant record of<br />
pertinent column information. Writing<br />
surface of tag is 1" x 2" (25.4 x 50.8mm). Order a<br />
Vibrograver at right to permanently inscribe the tags.<br />
COLUMN TAGS<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Embossed <strong>GC</strong> Tags 100 8011<br />
Embossed <strong>GC</strong> Tags 25 8012<br />
Embossed LC Tags 25 8005<br />
Plain Tags 100 8009<br />
© Copyright 2004 Alltech Associates, Inc.<br />
5082<br />
5074<br />
Pressed Frits<br />
These frits are precisionfabricated<br />
from Type 316 stainless<br />
steel and are ideal for sealing the<br />
ends of <strong>GC</strong> columns.<br />
Pressed frits are easy to install.<br />
Drill the column ends to the<br />
proper diameter and depth using<br />
the drill bits sold below. Rest<br />
the frit on top of the tubing and<br />
gently tap it into place.<br />
PORE<br />
DIAMETER<br />
QTY.<br />
Pressed<br />
Frits<br />
STAINLESS STEEL PRESSED FRITS<br />
FOR USE WITH 1/8"<br />
O.D. TUBING<br />
FOR USE WITH 1/4"<br />
O.D. TUBING<br />
0.5µm 25 702625 —<br />
2.0µm 25 703425 703525<br />
5.0µm 25 702825 702925<br />
10.0µm 25 703025 703125<br />
20.0µm 25 703225 703325<br />
Drill Bits<br />
These drill bits are specifically<br />
designed to prepare tubing for<br />
frit installation. They include a<br />
bushing that acts as a stop to control<br />
the depth of the hole.<br />
DRILL BITS<br />
Column<br />
Contact your Alltech office or distributor for current or local prices.<br />
1050<br />
PRICE<br />
DIAMETER QTY. PART NO. PRICE<br />
for 1/8" Frits ea 7032<br />
for 1/4" Frits ea 7033<br />
Vibrograver<br />
Use for engraving or<br />
column packing. A carbide<br />
point is included. Remove<br />
the point to use for column<br />
packing. Order replacements<br />
below.<br />
VIBROGRAVER<br />
DESCRIPTION PART NO. PRICE<br />
Vibrograver<br />
110V 8006<br />
220V 8018<br />
Replacement Point<br />
Diamond 15044<br />
Carbide 15045<br />
5086<br />
6633<br />
5076<br />
389
Gas Flow<br />
A C C E S S O R I E S<br />
Cylinder <strong>Accessories</strong><br />
Cylinder Status Tags<br />
Cylinder status tags help to<br />
organize and positively identify<br />
cylinders.<br />
CYLINDER STATUS TAGS<br />
DESCRIPTION PART NO. PRICE<br />
Cylinder Status Tags, 25/pk 8004<br />
Cylinder Tools<br />
Conveniently open valves, tighten gauges,<br />
connections, regulators, etc.<br />
5250<br />
Flash Arrestors<br />
• Prevent dangerous flashbacks<br />
• Meets OSHA requirements<br />
Flash arrestors shut off gas flow<br />
6099<br />
in the event of a flashback and<br />
extinguish the flame within the housing before it reaches<br />
your gas source. Flash arrestors are available in brass for<br />
general laboratory applications and stainless steel for<br />
high purity applications.<br />
Specifications<br />
PART NO. 37126 PART NO. 37128<br />
Materials of Construction<br />
Body: Brass 316 SS<br />
Seat: Butyl Rubber Viton A<br />
O-rings: Butyl Rubber PTFE-coated Viton<br />
Internal Parts: Brass & Steel SS<br />
Connections:<br />
1/4" FPT<br />
Max Service Pressure: Acetylene and Natural Gas - 15 psig<br />
Oxygen - 150 psig<br />
Propane and Hydrogen - 50 psig<br />
Dimensions:<br />
2" o.d. x 3-1/2"L (without fittings)<br />
Weight:<br />
2 lbs<br />
390<br />
6777<br />
Cylinder Valve & Cap Wrench<br />
© Copyright 2004 Alltech Associates, Inc.<br />
9-way Cylinder Wrench<br />
CYLINDER TOOLS<br />
DESCRIPTION PART NO. PRICE<br />
Tools<br />
Cylinder Valve & Cap Wrench 37135<br />
9-Way Cylinder Wrench 412933<br />
Cylinder Holders<br />
Prevent toppling<br />
of cylinders with<br />
these cast aluminum<br />
cylinder holders.<br />
Holders feature a<br />
nylon web strap with<br />
a sturdy buckle and<br />
are available with an<br />
optional safety chain.<br />
Cylinder holders<br />
wall mount cylinder holder<br />
with safety strap<br />
handle cylinders from 4 to 15 inches in diameter. Choose<br />
from benchtop or wall mount styles.<br />
CYLINDER HOLDERS<br />
DESCRIPTION PART NO. PRICE<br />
Bench Top Model with Cylinder Strap 37132<br />
Bench Top Model with Cylinder Strap and Safety 37214<br />
Chain<br />
Wall Mount Model with Cylinder Strap 37133<br />
Wall Mount Model with Cylinder Strap and Safety 37215<br />
Chain<br />
5178<br />
6098<br />
FLASH ARRESTORS<br />
DESCRIPTION PART NO. PRICE<br />
Brass 37126<br />
316 SS 37128<br />
Matheson Switchover Systems<br />
• Automatically change cylinders<br />
• Compact design minimizes wall<br />
space consumption<br />
Automatically switch from<br />
one cylinder to another without<br />
interruption providing a continuous<br />
6094<br />
supply of gas. Systems also minimize the risk of<br />
ambient contamination within your gas delivery network.<br />
Available in brass or stainless steel and with or without<br />
regulators. Order connecting flex hose separately under<br />
“<strong>Accessories</strong>” below.<br />
MATHESON SWITCHOVER SYSTEMS<br />
DESCRIPTION PART NO. PRICE<br />
Matheson Switchover Systems<br />
Model 5234 Brass 37139<br />
Model 5244 SS 37143<br />
Model 5230 Brass w/Regulator 37138<br />
Model 5240 SS w/Regulator 37141<br />
<strong>Accessories</strong> (Flex Hoses)<br />
3ft. SS with 1/4" NPT Female Connections 37118<br />
3ft. SS with Brass CGA Connections* 37122<br />
3ft. SS with SS CGA Connections* 37124<br />
* Specify CGA number.<br />
For additional information on Matheson<br />
Switchover Systems, request Data Sheet 37138.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Gas Flow<br />
Flow Controllers<br />
Flow Diverter<br />
Easily divert the gas stream from<br />
your detector to your soapfilm<br />
flowmeter. One Flow Diverter<br />
is required for each gas. It is<br />
supplied with 1/8" fittings.<br />
FLOW DIVERTER<br />
DESCRIPTION PART NO. PRICE<br />
Flow Diverter 4200<br />
Adjustable Flow Controller<br />
• Control flow rates from 0.5 mL/min<br />
up to 1.6 L/min<br />
This adjustable flow controller<br />
features a user variable span<br />
adjustment permitting it to be used for<br />
a variety of flow ranges. Use the tenturn<br />
knob to easily adjust flow rates<br />
from zero to maximum. Pipe adapters<br />
for 1/8" o.d. tubing are included.<br />
Specifications:<br />
Flow rate: Adjustable from 1.6mL/min to 0.5L/min<br />
Body:<br />
Aluminum<br />
Diaphragm: Stainless Steel<br />
Max Pressure: 250psig<br />
Max Temp: 120°C<br />
Ports:<br />
1/8" MPT<br />
FLOW CONTROLLER<br />
DESCRIPTION PART NO. PRICE<br />
Adjustable Flow Controller 8149<br />
Eco-Mizer<br />
• Conserve expensive gases during<br />
standby periods<br />
• Decrease laboratory operating expenses<br />
• Directly connects to 1/8" o.d. tubing<br />
The Eco-Mizer is a compact standby<br />
valve designed to conserve gases overnight<br />
and during other non-use periods. The adjustable<br />
fine metering valve sets the standby flow rate and a<br />
concentric, independent valve allows selection of either<br />
standby flow rate or straight-through flow.<br />
ECO-MIZER<br />
DESCRIPTION PART NO. PRICE<br />
Eco-Mizer 7070<br />
© Copyright 2004 Alltech Associates, Inc.<br />
5226<br />
5227<br />
5251<br />
Aalborg Flow Controllers<br />
Tiltable LCD readout<br />
for easy viewing<br />
• Indicate and control<br />
set flow rates of gases<br />
• Compact design won’t<br />
take up valuable bench<br />
space<br />
• NIST traceable<br />
certification<br />
These flow controllers<br />
feature a built-in<br />
electromagnetic valve<br />
4202<br />
that allows the flow to<br />
be set to any desired rate within the flow range. The<br />
valve is normally closed to ensure that gas flow is shut<br />
off in the event of a power outage. Setpoints can be<br />
controlled locally or remotely via the 4-20mA output.<br />
The LCD readout can be tilted over 90° and is easily<br />
removable for remote reading. Flow controllers are<br />
available in aluminum and brass for use with noncorrosive<br />
gases or 316 stainless steel for corrosive<br />
applications. Order power supply separately under<br />
“<strong>Accessories</strong>”.<br />
Specifications:<br />
Accuracy:<br />
+/-1.5% full scale<br />
Repeatability:<br />
+/-0.5% full scale<br />
Max Pressure:<br />
500psig<br />
Ambient Temperature: 5 to 50°C<br />
Output:<br />
0-5 VDC, 4-20mA<br />
Connections:<br />
1/4" compression<br />
Display:<br />
3-1/2 digit LCD<br />
Power:<br />
Order power supply separately<br />
FLOW RATE<br />
FLOW CONTROLLERS*<br />
ALUMINUM BODY<br />
PART NO.<br />
ACCESSORIES<br />
PRICE<br />
SS BODY<br />
PART NO.<br />
0-50mL/min 74428 $775.00 74435<br />
0-100mL/min 74429 775.00 74436<br />
0-200mL/min 74430 775.00 74437<br />
0-500mL/min 74431 775.00 74438<br />
0-1L/min 74432 775.00 74439<br />
*Please specify metered gas, and flow range<br />
PRICE<br />
DESCRIPTION PART NO. PRICE<br />
Flow Controller Power Supplies<br />
110V/12VDC 74487<br />
220V/12VDC European 74488<br />
Shield Cable, 8ft., Unterminated Ends 74492<br />
Battery Pack (Includes Case)<br />
110V 74418<br />
220V 74419<br />
Contact your Alltech office or distributor for current or local prices.<br />
391
Gas Flow<br />
A C C E S S O R I E S<br />
Flowmeters<br />
Soapfilm Flowmeter<br />
Economical flow measurement<br />
This soapfilm flowmeter is easy to use.<br />
Simply time the movement of a soap bubble<br />
be tween two calibration marks. Alltech’s<br />
soapfilm flowmeters have a unique bubble<br />
burster at the top to eliminate the overflow of<br />
the soap solution. A rubber bulb is included<br />
with each soapfilm flowmeter. The 100µL and<br />
500µL flowmeters are complete with stand and<br />
tubing. Order soapfilm solution and tubing under<br />
“<strong>Accessories</strong>” below.<br />
SOAPFILM FLOWMETERS<br />
DESCRIPTION PART NO. PRICE<br />
Flowmeters<br />
100µL 14184<br />
500µL 14185<br />
1cc 4041<br />
10cc 4042<br />
25cc 4043<br />
100cc 4045<br />
1000cc 4047<br />
<strong>Accessories</strong><br />
Soapfilm Solution, 8oz 2040<br />
5/16" o.d. Tygon Tubing, 10ft 4333<br />
Need Help Timing Your Flowmeter?<br />
Lightweight Stopwatch<br />
This stopwatch counts up to 24 hours with<br />
0.01sec readout and has split interval<br />
function, alarm clock with a choice of 12 or<br />
24 hour format, a calendar displaying date<br />
and day of the week, hourly chime option<br />
and button cell battery.<br />
Large Display Stopwatch<br />
This stopwatch features a large, 1/2" LCD<br />
display. It counts with a resolution of<br />
0.01sec and has split interval, clock and<br />
calendar functions. It includes a rugged<br />
ABS plastic clip, neck cord, leatherette<br />
case, stand clip and a 1.5V battery.<br />
5195<br />
Digital Soapfilm<br />
Flowmeter<br />
Patented U-tube design<br />
for lighter than air gases<br />
• NIST traceable calibration<br />
• 2-3% of reading accuracy<br />
• LCD display<br />
• Autoranging<br />
Alltech digital soapfilm<br />
flowmeters provide for easy<br />
gas measurement and allow you to visually<br />
confirm gas flow. Flowmeters feature microprocessor<br />
control and display flow rates, default conditions and<br />
set test results on the LCD. Automatic shut off extends<br />
battery life and manual reset corrects fault conditions.<br />
Part No. 4068 also measures split ratios. Optional<br />
carrying case, tubing and tubing clamps are available<br />
under “<strong>Accessories</strong>” below.<br />
What’s included: 9V battery and operation manual<br />
DIGITAL SOAPFILM FLOWMETERS<br />
DESCRIPTION PART NO. PRICE<br />
Alltech Digital Flowmeter<br />
0.10-50mL/min 4074<br />
0.5-700mL/min 4068<br />
5.0mL- 5.00L/min 4077<br />
<strong>Accessories</strong><br />
Carrying Case 4087<br />
Small Tubing Clamp 4091<br />
Large Tubing Clamp 4093<br />
Gum Rubber Tubing, 3/32" i.d. x 24" 4099<br />
Replacement Parts<br />
Small Bulb 4095<br />
Large Bulb 4097<br />
Recalibration Service<br />
0.10-50mL/min 40740<br />
0.5-500mL/min 406801<br />
5.0mL- 5.00L/min 40770<br />
Visibly Detect Small Leaks in<br />
Any System<br />
Leak Check Solution<br />
5189<br />
STOPWATCHES<br />
DESCRIPTION PART NO. PRICE<br />
Lightweight Stopwatch 4069<br />
Large Display Stopwatch 4071<br />
LEAK CHECK<br />
DESCRIPTION PART NO. PRICE<br />
Leak Check, 8oz. 2025<br />
392<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Gas Flow<br />
Flowmeters<br />
Aalborg Single Tube Variable Area<br />
Flowmeters<br />
Built-in needle valve controls flow<br />
• Magnifier lens enhances reading<br />
resolution<br />
• Ideal for panel mounting<br />
Aalborg single tube flowmeters are<br />
equipped with easy to change flowtubes<br />
and a control valve. Each flowtube is<br />
precision fabricated from heavy wall,<br />
shock resistant borosilicate glass.<br />
Flowtubes are available in 65mm or<br />
150mm sizes. The floats are retained by<br />
TFE plugs. Order a bench stand and fittings separately<br />
under “<strong>Accessories</strong>” below.<br />
Specifications<br />
Accuracy: +/-5% full scale<br />
Repeatability: +/-0.25%<br />
Max Pressure: 200psig<br />
Max Temperature: 121°C<br />
Connections: 1/8" FPT inlet and outlet<br />
5198<br />
Aalborg Three Tube Variable Area Flowmeter<br />
Measure hydrogen, air and carrier gases with one<br />
meter<br />
• Direct reading for hydrogen and air<br />
• Carrier gas tube can be correlated for<br />
any gas<br />
• Can be panel-mounted or free standing<br />
This three tube flowmeter is ideal for<br />
monitoring carrier gas, hydrogen and<br />
5197<br />
air flows used with flame ionization<br />
detectors. A direct reading of hydrogen and air flow<br />
rates can be directly read on the flow tube. The carrier<br />
gas tube features a 0 to 76mm scale, graduated in 1mm<br />
increments. The tubes and flow control valves are easily<br />
disassembled for cleaning.<br />
Specifications<br />
Accuracy: +/-5% full scale<br />
Repeatability: +/-0.25%<br />
Max Pressure: 200psig<br />
Max Temperature: 121°C<br />
Connections: 1/8" FPT inlet and outlet<br />
SINGLE TUBE FLOWMETERS<br />
FLOWTUBE RANGE DIV. PART NO. PRICE<br />
65mm Flowtubes, Direct Reading Scale<br />
Helium 0-120cc/min 5mL 7900<br />
Hydrogen 0-100cc/min 5mL 7902<br />
Nitrogen 0-120cc/min 5mL 7904<br />
Air 0-1.15L/min .05L 7906<br />
General Purpose 0-2L/min (air) 1mm 7908<br />
150mm Flowtubes, Direct Reading Scale<br />
Helium 0-100cc/min 5mL 7910<br />
Hydrogen 0-100cc/min 5mL 7912<br />
Nitrogen 0-100cc/min 5mL 7914<br />
Air 0-1.25L/min .05L 7916<br />
General Purpose 0-2L/min (air) 1mm 7918<br />
<strong>Accessories</strong><br />
Bench Mount for Above Flowmeters 7920<br />
1/8" to 1/8" MPT Brass Connector 60038<br />
1/4" to 1/8" MPT Brass Connector 60042<br />
Need a leak detector?<br />
See page 397 for our<br />
complete selection.<br />
Portable Flow Check<br />
THREE TUBE FLOWMETER<br />
DESCRIPTION PART NO. PRICE<br />
Three Tube Flowmeter 4040<br />
Direct analog reading of gas flows<br />
• Easy-to-read 4-inch scale<br />
• NIST traceable calibration<br />
The Portable Flow Check allows you to directly<br />
measure air, nitrogen, helium and hydrogen flow rates.<br />
Each flowmeter is factory calibrated prior to<br />
shipment. A one-point NBS/NIST traceable calibration<br />
certificate is included with each flowmeter.<br />
Specifications<br />
Flow rate:<br />
He and N2:<br />
0-100mL/min<br />
H2: 0-200mL/min<br />
Air:<br />
0-500mL/min<br />
Max Pressure:<br />
15psig<br />
Accuracy:<br />
+/-5% full scale<br />
Display:<br />
Analog scale<br />
Dimensions:<br />
6-3/4"H x 2-1/2"W x 5-1/4"L<br />
5196<br />
© Copyright 2004 Alltech Associates, Inc.<br />
6711<br />
PORTABLE FLOW CHECK<br />
DESCRIPTION PART NO. PRICE<br />
Portable Flow Check 7080<br />
Contact your Alltech office or distributor for current or local prices.<br />
393
Gas Flow<br />
A C C E S S O R I E S<br />
Flowmeters<br />
Alltech Digital Flow Check Mass Flowmeters<br />
NIST traceable calibration for seven gases<br />
• Measure Air, Helium, Hydrogen, Nitrogen, Oxygen, 5% Argon/Methane and<br />
Carbon Dioxide<br />
• Water vapor will not affect readings—suitable for purge and trap applications<br />
• +/-2% of reading accuracy insures your flow rates are on target<br />
• DFC-HR high resolution model is ideal for low-flow applications<br />
Alltech’s model DFC and DFC-HR Digital Flow Check flowmeters feature<br />
unsurpassed versatility. Both models come standard with NIST traceable calibration<br />
for seven gases making them suitable for <strong>GC</strong> applications such as monitoring<br />
detector gases, packed column flow rates and determining split ratios. Flowmeters<br />
can be used in SFC, SFE, and industrial hygiene applications as well as in the<br />
general lab. Install flowmeters in-line for continuous flow monitoring to traps,<br />
6249<br />
sorbent tubes, incubators, fermentors or reaction vessels without interrupting gas<br />
flow. Use flowmeters with either a positive or negative (vacuum) flow source.<br />
The DFC and DFC-HR mass flowmeters incorporate a rugged solid-state sensor with microprocessor control that<br />
measures true mass flow eliminating the ambient temperature and pressure change errors associated with other types<br />
of flowmeters. Water vapor errors have also been eliminated. Flow measurements will be precise and accurate to<br />
within +/-2% of your reading. Gas flow travels straight through the meter reducing backpressure, internal volume<br />
and sensor purge time allowing for readings to stabilize quickly. Easily change between mass flow, linear velocity and<br />
split ratio modes.<br />
Both Digital Flow Check meters are shipped with an NIST traceable multi-point certificate of calibration<br />
that includes percent error data. Meters are calibrated for seven gases using NIST traceable standards. Periodic<br />
recalibration is recommended to maintain accuracy and compliance with ISO, GLP, GMP and other quality standards.<br />
Model DFC Standard Mass Flowmeter has a measurement range of 0.1 to 300 SCCM for CO2 and 0.1 to 500 SCCM<br />
for the remaining gases. It is lightweight, portable and easy to use. Display resolution of 0.1 SCCM makes it ideal<br />
for most applications.<br />
Model DFC-HR High Resolution Mass Flowmeter features a display resolution of 0.01 SCCM when measuring<br />
below 10 SCCM providing a higher degree of precision required for low-flow applications such as setting capillary <strong>GC</strong><br />
flow or leak testing. Measurement range is 0.01 to 300 SCCM for CO2 and 0.1 to 500 SCCM for the remaining gases.<br />
Use the autozero function to quickly zero the meter for current ambient conditions.<br />
What’s included: Both models include 1 ft of 1/32" (0.8mm) i.d. silicone tubing, 1 ft of 1/8" (3.8mm) i.d.<br />
silicone tubing, 2 barbed inlet/outlet fittings for each tubing size, a general purpose adapter to connect to Agilent<br />
FID, splint vent traps, packed <strong>GC</strong> columns and gas lines, split vent adapter for connection to Agilent <strong>GC</strong> split vents,<br />
and 9V battery. Model DFC-HR also includes a capillary column adapter. Replacement accessories on facing page.<br />
394<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Suggested Flowmeter Applications<br />
Low Flow Applications (DFC-HR )<br />
• Capillary <strong>GC</strong> Flows<br />
• Split Ratios<br />
• Leak Testing<br />
• Applications Requiring Precise Flow<br />
Measurement Below 10cc/min<br />
<strong>GC</strong> Applications (DFC and DFC-HR )<br />
• Detector Gases<br />
• Packed Column Flow<br />
• Split Ratios<br />
• Linear Velocity<br />
Lab Applications (DFC and DFC-HR )<br />
• Set Instrument Operating Parameters<br />
• Industrial Hygiene Applications<br />
• Monitor Flow to Traps, Sorbent Tubes,<br />
Incubators, Fermentors & Reaction Vessels<br />
• SFC and SFE Applications<br />
• In-Line Applications<br />
• Monitor Vacuum & Purging Processes<br />
• Gas Blending<br />
• Gas Sampling<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Gas Flow<br />
<strong>Accessories</strong> included with DFC & DFC-HR <br />
A<br />
B<br />
<strong>Accessories</strong>:<br />
1/16" (1.6mm) Barbed Inlet/Outlet Fitting for DFC-HR <br />
A<br />
Flowmeter (Part No. 5707)<br />
C<br />
F<br />
G<br />
D<br />
E<br />
B<br />
1/8" (3.8mm) Barbed Inlet/Outlet Fitting for DFC-HR <br />
Flowmeter (Part No. 5706)<br />
C Split Vent Adapter (Part No. 4705)<br />
D General Purpose Adapter (Part No. 4704)<br />
E Capillary Column Adapter (Part No. 5705)<br />
F 1/32" (0.8mm) i.d. Connecting Tubing (Part No. 4703)<br />
G 1/8" (3.8mm) i.d. Connecting Tubing (Part No. 4785)<br />
6557<br />
Flowmeter Specifications<br />
Flow range:<br />
Model DFC: 0.1 to 500 SCCM autoranging (except CO2); 0.1 to 300 SCCM autoranging for CO2<br />
Model DFC-HR: 0.01 to 500 SCCM autoranging (except CO2); 0.01 to 300 SCCM autoranging for CO2<br />
Accuracy:<br />
Model DFC: +/-2% of reading or 0.1 SCCM<br />
Model DFC-HR: +/-2% of reading or 0.01 SCCM (for range of 0.01 to 9.99 SCCM),0.1 SCCM (for range of 10 to 500 SCCM)<br />
Calibrated Gases: He, H2, N2, O2, CO2, Air, Ar/CH4 (5%)<br />
Sensor type: Solid-state mass flow, silicon on ceramic<br />
Display:<br />
16-character alphanumeric LCD, autoranging<br />
Display modes: Mass flow, split ratio, linear velocity (standard flow range)<br />
Power:<br />
9V alkaline battery (included), auto-off function, low battery warning<br />
Dimensions: 190.5 x 57.4 x 101.6mm (7.5” x 2.26” x 4.0”)<br />
Keep your flowmeter in check!<br />
When it’s time to recalibrate your<br />
Digital Flow Check , contact Alltech<br />
Customer Service!<br />
DIGITAL FLOW CHECK FLOWMETERS<br />
MODEL PART NO. PRICE<br />
DFC 4700<br />
DFC-HR 5700<br />
Insure your connections are leak free<br />
© Copyright 2004 Alltech Associates, Inc.<br />
See page 397 for Alltech's<br />
Helium Leak Detector<br />
REPLACEMENT ACCESSORIES<br />
DESCRIPTION PART NO. PRICE<br />
1/16" (1.6mm) Barbed Inlet/Outlet Fitting<br />
for DFC-HR , 2/pk<br />
1/8" (3.8mm) Barbed Inlet/Outlet Fitting<br />
for DFC-HR , 2/pk<br />
5707<br />
5706<br />
Split Vent Adapter 4705<br />
General Purpose Adapter 4704<br />
Capillary Column Adapter for DFC-HR 5705<br />
1/32" (0.8mm) i.d. Connecting Tubing, 10' 4703<br />
1/8" (3.8mm) i.d. Connecting Tubing, 1m 4785<br />
Contact your Alltech office or distributor for current or local prices.<br />
395
Gas Flow<br />
A C C E S S O R I E S<br />
Flowmeters<br />
Agilent ADM Digital Flowmeters<br />
Measure any non-corrosive, non-flammable gas<br />
• Continuous, hands-free<br />
flow measurement<br />
• Quickly measure split<br />
ratios<br />
• NIST traceable<br />
calibration<br />
These Agilent ADM<br />
flowmeters are ideal for<br />
6313<br />
basic <strong>GC</strong> analysis. They<br />
accurately measure<br />
volumetric gas flow making them compatible with any<br />
non-corrosive, non-flammable gas. Flowmeters are easy<br />
to use — flow measurements are displayed at the touch<br />
of a button. All meters include five-point calibration<br />
traceable to NIST standards.<br />
ADM-1000 - This basic flowmeter has all of the<br />
features required for basic <strong>GC</strong> analysis—continuous real<br />
time volumetric flow measurements, automatic split ratio<br />
measurements and operates on a 9V battery.<br />
ADM-3000 - This standard flowmeter includes all of<br />
the features of the ADM-1000, as well as RS-232 output<br />
for data logging. Flowmeter operates on AC power or a<br />
9V battery<br />
ADM-2000 - This deluxe flowmeter includes all of<br />
the features of the ADM-3000 plus it measures mass<br />
flow rates independent of atmospheric temperature and<br />
pressure.<br />
Specifications<br />
Accuracy: +/-3%<br />
Display:<br />
16-character alphanumeric<br />
AGILENT ADM DIGITAL FLOWMETERS<br />
MODEL DESCRIPTION FLOW RATE RS-232 OUTPUT POWER PART NO. PRICE<br />
ADM 1000 Basic 0.5-1000 mL/min No 9V battery 9965<br />
ADM 3000 Standard 1.0-750 mL/min Yes 9V battery or AC 6365<br />
ADM 2000 Deluxe 0.5-1000 mL/min Yes 9V battery or AC 7065<br />
Aalborg Mass Flowmeters<br />
Handle pressures up to 500psig<br />
• Tiltable LCD readout for<br />
easy viewing<br />
• Flow rates displayed in<br />
engineering units<br />
• NIST traceable<br />
certification<br />
2595<br />
Specifications<br />
Accuracy<br />
+/-1.5% full scale<br />
Repeatability +/-0.5%<br />
Max Pressure<br />
500psig<br />
Max Temperature 50°C<br />
Display<br />
3-1/2 digit LCD<br />
Output<br />
0-5 VDC or 4-20mA<br />
Connections<br />
1/4" compression fittings<br />
AALBORG FLOWMETERS*<br />
These compact mass flowmeters are designed to<br />
directly read flow rates of gases. Meters feature a<br />
display module that is tiltable over 90 degrees and can<br />
be easily removed for remote reading. Flowmeters are<br />
available in aluminum or stainless steel and can be used<br />
on the benchtop or wall-mounted. Order power supply<br />
separately under “<strong>Accessories</strong>”.<br />
FLOW RATE<br />
ALUMINUM BODY<br />
PART NO.<br />
PRICE<br />
SS BODY<br />
PART NO.<br />
0-50 mL/min 74400 74401<br />
0-100 mL/min 74402 74403<br />
0-200 mL/min 74404 74405<br />
0-500 mL/min 74406 74407<br />
0-1 L/min 74422 74425<br />
<strong>Accessories</strong> (Power Supplies)<br />
110V/12VDC 7447<br />
220V/12VDC European 7449<br />
*specify type of gas and pressure range when ordering<br />
PRICE<br />
396<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Gas Flow<br />
Gas Leak Detection<br />
Alltech Helium Leak Detector<br />
Designed specifically to detect helium gas leaks<br />
• Portable—operates up to 6.5 hours fully charged<br />
• Visual and audible detection<br />
indicators<br />
• Change polarity setting to<br />
detect other gases<br />
The Alltech helium leak detector is perfect for<br />
detecting gas leaks in <strong>GC</strong>, <strong>GC</strong>/MS, and purge/trap<br />
systems. Leaks are detected via a thermal conductivity<br />
cell and indicated visually on the LCD display and by<br />
an audible alarm. The long flexible probe makes it<br />
convenient to detect small and hard to reach gas leaks.<br />
Use the detector for gases other than helium by simply<br />
changing the polarity setting. Detector features a<br />
simple one-step zero adjustment and is fully portable<br />
operating on rechargeable Ni-Cd batteries.<br />
What’s included: probe, rechargeable batteries and<br />
charger<br />
Helium Leak Detector<br />
Detector: Thermal conductivity cell with thermistors<br />
Sensitivity: 0.01 mL/min for Helium<br />
Ambient Temp: 10 to 35°C<br />
Display: LCD indicator lights<br />
Zero Function: Yes<br />
Audible Signal: Yes<br />
Battery Life: 6.5 hours continuous fully charged<br />
Dimensions: 2.9"W x 1.6"H x 6.3"L<br />
(7.366cmW x 4.064cmH x 16.002cmL)<br />
Weight:<br />
1 lb (.454 kg)<br />
Note: The Alltech helium leak detector is not explosion-proof and should not<br />
be used to detect combustible or corrosive gas leaks<br />
HELIUM LEAK DETECTOR<br />
POWER DESCRIPTION PART NO. PRICE<br />
120 VAC charger w/rechargeable Ni-Cd batteries 60229<br />
220 VAC charger w/rechargeable Ni-Cd batteries 60231<br />
6711<br />
6428<br />
Gow-Mac ® Gas Leak Detectors<br />
Control meter sensitivity — ideal for detecting<br />
small leaks<br />
• Zero in ambient air<br />
• Detect helium leaks as small as<br />
1.0 x 10-5mL/sec<br />
These gas leak detectors easily<br />
and quickly pinpoint gas leaks<br />
5239<br />
emitting from pressurized systems.<br />
The detectors conveniently zero in ambient air and<br />
feature a streamlined probe that is designed to reach<br />
difficult and confined spaces.<br />
The portable model is light weight and features an<br />
LED bar graph visual readout and automatic zeroing. The<br />
benchtop model has an audible signal in addition to the<br />
analog graduated scale.<br />
What’s included: probe with 3ft cable, rechargeable<br />
batteries and power adapter.<br />
Specifications<br />
PORTABLE<br />
BENCHTOP<br />
Detector:<br />
Thermal conductivity cell with thermistors<br />
Range:<br />
Low: x1 High: x100<br />
Sensitivity:<br />
1.0 x 10-5 mL/sec for helium<br />
Display: LED bar graph Graduated analog scale<br />
Zero Function: Automatic Manual<br />
Audible Signal: None Yes<br />
Battery Life: 3.5 hours 4 hours<br />
Dimensions: 3-1/4"W x 1-13/16"H x<br />
5-1/4"L<br />
(8.255cmW x 2.064cmH<br />
x 13.335cmL)<br />
8-1/4"W x 3-5/8"H x<br />
10-3/4"L<br />
(20.955cmW x 9.206cmH<br />
x 27.305cmL)<br />
Weight: 2 lbs (.9072 kg) 9 lbs (4.082 kg)<br />
GAS LEAK DETECTORS<br />
DESCRIPTION PART NO. PRICE<br />
Portable<br />
115VAC/60Hz or rechargeable Ni-Cd batteries 21-050<br />
230VAC/50Hz or rechargeable Ni-Cd batteries 21-052<br />
Benchtop<br />
115VAC/60Hz or rechargeable battery pack 21-250<br />
230VAC/50Hz or rechargeable battery pack 21-252<br />
<strong>Accessories</strong><br />
Carrying case for portable gas leak detectors 59-050<br />
Leak-Tec ® High Temp Testing Solution<br />
Temperature range is 210 to 415°F<br />
This testing solution wets and spreads evenly<br />
and quickly responding to small leaks. Leak-Tec ® is<br />
non-corrosive and residue free. Convenient aerosol<br />
can allows spray to be directed in tight spaces.<br />
5241<br />
Leak-Check Testing Solution<br />
Leak-Check is non-toxic, non-flammable,<br />
chloride-free and dries cleanly leaving no residue<br />
behind. Temperature range is 30 to 200°F.<br />
Bottle includes a 15" snorkel tube allowing for<br />
easy access to hard-to-reach spaces.<br />
5242<br />
LEAK-TEC ®<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Leak-Tec ® , 10oz ea 2027<br />
6 2028<br />
© Copyright 2004 Alltech Associates, Inc.<br />
LEAK-CHECK <br />
POWER DESCRIPTION QTY. PART NO. PRICE<br />
Leak-Check , 8oz ea 2025<br />
12 2026<br />
Contact your Alltech office or distributor for current or local prices.<br />
397
Purifiers<br />
A C C E S S O R I E S<br />
Gas Purifiers and Traps<br />
Why Use Gas Purifiers?<br />
A clean gas stream helps guarantee the quality of<br />
your <strong>GC</strong> analysis and the reliability of your results. It<br />
also helps prolong column life and minimize detector<br />
noise. Gas purifiers act as an insurance policy, protecting<br />
your instrumentation and analytical columns from these<br />
contaminants. They will not however, convert low purity<br />
gas into ultra high purity gas. Alltech carries a variety<br />
of gas purifiers in three different styles. See Table 1 for<br />
details.<br />
5333 5334 5335<br />
Baseplate Style Cartridge Style In-Line Style<br />
Table 1 - Gas Purifier Styles<br />
STYLE BASEPLATE CARTRIDGE IN-LINE<br />
Placement:<br />
Stands on<br />
Benchtop<br />
Stands on<br />
Benchtop<br />
Freely supported on<br />
gas lines<br />
Repeat Use: Refill* Replace Cartridge Refill*<br />
Benefit: Convenient<br />
access, no<br />
mounting<br />
required<br />
Convenient access,<br />
stops gas flow<br />
when changing<br />
cartridges<br />
Occupies wall space<br />
not bench space<br />
*Refills for most materials are available. See specific gas purifiers for refill kit<br />
part numbers.<br />
Choosing the Right Gas Purifier for Your<br />
Application<br />
There are a variety of gas purifiers available.<br />
Some remove a specific contaminant while others<br />
remove multiple contaminants from your gas stream.<br />
There are several factors you need to consider when<br />
selecting purifiers for your application. These include<br />
contaminants potentially present in your gas stream,<br />
gas purity levels required, flow and pressure limitations,<br />
space availability, and desired convenience when<br />
replacing spent traps.<br />
Moisture, hydrocarbon, and oxygen traps are the most<br />
commonly used purifiers for <strong>GC</strong> applications. Moisture<br />
traps are typically packed with molecular sieves. After<br />
extensive heating, these crystalline structures lose their<br />
water of hydration opening a cavity that is readily filled<br />
with any compound that can fit. Water fits perfectly.<br />
However, it will also remove HCl, CO2, SO2, Cl2, or any gas<br />
with an effective diameter smaller than water.<br />
Hydrocarbon traps are packed with an activated<br />
charcoal that adsorbs any organic compound larger<br />
than methane. Size and molecular weight of the<br />
organic contaminants will greatly effect the capacity<br />
of the trap, and to a smaller degree, trap efficiency.<br />
Activated charcoal has a higher capacity for larger (>C4)<br />
hydrocarbons than for smaller hydrocarbons.<br />
Oxygen traps are packed with a metal catalyst.<br />
Oxygen is the most detrimental contaminant to<br />
analytical columns. It produces irreversible oxidation<br />
damage particularly to polar stationary phases. Refer to<br />
Table 2 for a recommendation of what purifiers to use<br />
for various <strong>GC</strong> applications.<br />
398<br />
How Contaminants Affect Your Gas Stream<br />
Follow the path that your carrier gas or detector fuel<br />
gases take to get to the <strong>GC</strong>. They start at either a gas<br />
tank or a gas generator, and travel through long lengths<br />
of tubing, pressure gauges, various fittings, and valves.<br />
Each is a potential culprit for introducing contaminants<br />
into your gas stream, which ultimately degrades<br />
chromatography results and shortens column life.<br />
Typical contaminants, such as moisture, oxygen,<br />
and hydrocarbons wreak havoc with <strong>GC</strong> columns and<br />
detectors. Capillary and packed columns can degrade<br />
when exposed to moisture or oxygen, particularly at<br />
high temperatures. Detector performance may also be<br />
compromised. Since the detector can actually “see” the<br />
contaminants, spikes, baseline noise, and drift result.<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Table 2 - Gas Purifier Recommendations<br />
SYSTEM DETECTOR GAS STREAM RECOMMENDED PURIFIER<br />
Packed Column <strong>GC</strong><br />
All Carrier Gas Hydrocarbon, Moisture,<br />
Oxygen, and Indicating<br />
Oxygen<br />
Capillary Column <strong>GC</strong><br />
All Carrier Gas Hydrocarbon, Moisture,<br />
Oxygen, and Indicating<br />
Oxygen<br />
ECD Make-Up Moisture and Oxygen<br />
FID Make-Up Hydrocarbon<br />
FID Air for FID Hydrocarbon<br />
FID Hydrogen for FID Hydrocarbon<br />
ELCD ELCD Reaction Gas Hydrocarbon<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Purifiers<br />
Physical Characteristics<br />
You will also need to consider what physical<br />
characteristics your purifier should possess to meet your<br />
application requirements. Do you require 1/8" or 1/4"<br />
fittings, or are you performing bulk gas purification<br />
that requires 1/2" fittings? What are the pressure<br />
requirements of your application? This will determine if<br />
you need a purifier with a polycarbonate, glass, or metal<br />
body. Where will you be installing the purifier and is<br />
your installation space limited? This will determine the<br />
dimension and style of purifier you should choose.<br />
Purifier Styles<br />
Alltech offers three purifier styles – in-line, baseplate,<br />
and cartridge. The in-line style is the traditional style<br />
that is most commonly used. It can be directly installed<br />
into your gas lines with no support depending on its<br />
dimension or can be easily mounted on the wall with<br />
mounting clips. In-line purifiers must be removed from<br />
the gas line to be refilled or regenerated. We recommend<br />
installing them with quick-connect connectors and<br />
keeping an extra purifier on hand.<br />
The baseplate and cartridge purifiers sit on the<br />
countertop making them easy to access when it is time<br />
to replace spent traps. Both styles can be installed in<br />
series with shut off valves allowing you to easily isolate<br />
them from your gas lines when it is time to replace<br />
them. Baseplate units allow you to easily refill the<br />
purifier with new adsorbent material. Cartridge purifiers<br />
allow you to quickly remove the spent purifier from your<br />
gas line and replace it with a new one.<br />
Purifier Capacity<br />
Purifier capacity indicates the amount of contaminant<br />
a trap is capable of removing before it reaches its point<br />
of saturation. It is dependent on both the adsorbent’s<br />
capabilities and purifier’s volume. You need to consider<br />
the amount of impurities in your gas stream and the<br />
volume of gas you need to purify. If you are purifying a<br />
large volume of gas or a less pure gas, you should select<br />
a high capacity trap with a large volume adsorbent bed<br />
that will trap and retain more contaminants.<br />
Purifier Efficiency<br />
Purifier efficiency is the most important purifier<br />
characteristic. It indicates how effective the adsorbent<br />
is at removing the desired contaminant from your gas<br />
stream. If your application requires high purity levels<br />
or the lowest detection limits, select a purifier that is<br />
packed with a highly efficient adsorbent material that<br />
removes contaminants to ppb levels.<br />
<br />
<br />
Figure 1 — How to Set Up Carrier Gas Purifiers<br />
1. High Capacity or Indicating Moisture Trap<br />
2. High Capacity or Indicating Hydrocarbon Trap<br />
<br />
<br />
<br />
<br />
<br />
<br />
Gas Purifier Installation Order<br />
The order in which you install purifiers into your gas<br />
lines is very important. Figure 1 demonstrates the<br />
correct order for installing purifiers into your carrier<br />
gas line. The moisture trap should be placed first in<br />
line. Both hydrocarbon and oxygen traps will adsorb<br />
water. Installing a moisture trap before these traps<br />
prevents them from becoming prematurely saturated with<br />
moisture. It also allows them to more effectively remove<br />
their specified contaminants from the gas stream. The<br />
hydrocarbon trap should be placed after the moisture<br />
trap. A high capacity oxygen trap and an indicating<br />
oxygen trap should be placed closest to the <strong>GC</strong>. We<br />
recommend installing the series of purifiers as close to<br />
the <strong>GC</strong> as possible.<br />
Gas purifiers should be installed in a vertical position<br />
to prevent channeling. Channeling is a phenomenon<br />
that occurs when a purifier is installed in a horizontal<br />
position. The adsorbent bed settles and the gas stream<br />
passes over the top of the bed rather than through the<br />
bed. The gas stream does not sufficiently interact with<br />
the adsorbent bed to effectively remove impurities.<br />
Gas purification systems simplify purifier installation<br />
in to your gas lines. Systems are available as multiadsorbent<br />
single purifiers or compact panels that contain<br />
multiple purifiers.<br />
Purifier Replacement/Regeneration<br />
3. Oxygen Trap (high<br />
capacity)<br />
4. Indicating Oxygen<br />
Trap<br />
You need to replace your gas purifiers before they<br />
are fully saturated. You can either change them at a<br />
predetermined time interval or use an indicating trap<br />
that changes color as it becomes saturated. There<br />
are potential problems with scheduled replacements.<br />
Undetected leaks or accidental exposure to air during<br />
cylinder changes can prematurely saturate gas purifiers.<br />
Early breakthrough means your column and detectors are<br />
exposed to a constant stream of damaging contaminants.<br />
An indicating trap located downstream from a high<br />
capacity trap is the best way to determine when it’s<br />
time to replace a spent trap. Some purifiers contain<br />
both the high capacity and indicating adsorbent in the<br />
same purifier body while others rely on a separate trap<br />
that serves solely as an indicator. Either way, purifier<br />
replacement should coincide with the first signs of color<br />
change in the indicating adsorbent.<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
4138<br />
399
Purifiers<br />
A C C E S S O R I E S<br />
Alltech Moisture Traps<br />
Remove moisture from your gas system<br />
• Eliminate stationary phase degradation<br />
• Increase column life<br />
• Improve the quality of your chromatography<br />
Remove moisture from gas cylinders, regulators and<br />
gas lines with an Alltech moisture trap. In addition<br />
to H2O, most traps (except the ALL-Pure and Sodium<br />
Sulfate) also remove HCl, SO2, NO2, H2S, CO2, oil, and<br />
small aliphatics. Both indicating and non-indicating<br />
traps are available. Many traps can be regenerated and<br />
are refillable—order refill kits separately.<br />
Alltech offers a wide variety of moisture traps to<br />
meet all of your gas purifying needs. Choose from three<br />
different styles.<br />
Cartridge & Baseplate Style<br />
Moisture Traps<br />
A) Baseplate Style Moisture Traps<br />
- Convenient access for refilling/changing<br />
- sits on the benchtop - requires no<br />
mounting<br />
4659<br />
B) Cartridge Style Moisture Traps<br />
- Simply replace the cartridge when spent<br />
- Gas flow stops while cartridge is changed<br />
- Order baseplate unit separately below<br />
4660<br />
CARTRIDGE AND BASEPLATE MOISTURE TRAPS<br />
CAPACITY<br />
PRESSURE<br />
LIMIT<br />
DIMENSIONS<br />
(L X O.D.) INDICATOR PART NO. PRICE<br />
REFILL KIT<br />
PART NO.<br />
PHOTO CARTRIDGE DESCRIPTION (ML) EFFICIENCY<br />
FITTING<br />
Cartridge & Baseplate Style Traps<br />
1/8"<br />
8122 8132<br />
12<br />
12.5" x 1.5"<br />
1/4" 8126 8132<br />
A Baseplate Moisture Trap<br />
A C C E S S O R I E S<br />
Purifiers<br />
G) Glass Moisture Trap<br />
- Best for carrier gas lines<br />
- Glass housing eliminates diffusion<br />
- 40µm SS frits in endfittings prevent particulates from<br />
entering gas stream<br />
H) ALL-Pure Moisture Trap<br />
- Removes moisture down to
Purifiers<br />
A C C E S S O R I E S<br />
Alltech Oxygen Traps<br />
Protect columns from oxygen contamination<br />
Prevent oxidation of column stationary phases with<br />
Alltech oxygen traps. Use an oxygen trap to help<br />
maintain column performance and prolong column<br />
life. Traps are available in cartridge and in-line styles.<br />
Choose an indicating trap to easily identify when trap<br />
is spent or to use in conjunction with larger capacity<br />
traps. Some traps can be regenerated—see table on<br />
following page.<br />
4828<br />
Cartridge Style Oxygen Traps<br />
A) AT -Indicating Oxy Cartridge<br />
- features the OXY-MAX adsorbent<br />
- Easy to replace - simply change cartridge<br />
- Gas flow stops while cartridge is charged<br />
- Order baseplate separately below<br />
Alltech’s OXY-MAX is<br />
the most efficient oxygen<br />
adsorbent available.<br />
Traps containing OXY-MAX remove 02 to<br />
less than 1ppb.<br />
4829<br />
B) AT -Omni Cartridge<br />
- features the OXY-MAX adsorbent<br />
- Also removes moisture and hydrocarbons<br />
- Easy to replace - simply change<br />
cartridge<br />
- Gas flow stops while cartridge is charged<br />
- Order baseplate separately below<br />
CARTRIDGE OXYGEN TRAPS<br />
PHOTO DESCRIPTION CAPACITY(ML) EFFICIENCY PRESSURE LIMIT DIMENSIONS (L X O.D.) INDICATOR PART NO. PRICE<br />
Cartridge Style Traps<br />
A AT -Indicating Oxy 104
A C C E S S O R I E S<br />
Purifiers<br />
G) Oxy-Purge ® N<br />
- Also removes moisture<br />
- Rugged aluminum housing<br />
- 40µm SS frits in endfittings prevent particulates<br />
from entering gas stream<br />
H) ALL-Pure Oxygen Trap<br />
- Also removes moisture<br />
- Capacity of 1030mL of oxygen<br />
4835<br />
4832<br />
I) Oxi-Clear ® Oxygen Trap<br />
- Removes oxygen, moisture, and hydrocarbons<br />
J) BIG Oxygen Trap<br />
- Our highest capacity trap—3000mL<br />
4839<br />
4831<br />
K) High Pressure Oxy-Trap <br />
- Features OXY-MAX adsorbent<br />
- Handles pressures up to 1800psig<br />
L) Low Pressure Oxisorb ®<br />
- Also removes moisture<br />
4830<br />
4837<br />
PHOTO<br />
DESCRIPTION<br />
CAPACITY<br />
(ML)<br />
EFFICIENCY<br />
IN-LINE OXYGEN TRAPS<br />
PRESSURE<br />
LIMIT<br />
FITTING<br />
DIMENSIONS<br />
(L X O.D.) INDICATOR PART NO. PRICE<br />
REGENERATION<br />
SERVICE<br />
PART NO.<br />
In-Line Style Traps<br />
C Oxy-Trap 133
Purifiers<br />
A C C E S S O R I E S<br />
Alltech Hydrocarbon, CO2, and Sulfur Traps<br />
Eliminate detector noise and increase<br />
baseline stability<br />
• Choose baseplate, cartridge, or in-line styles<br />
• Indicating hydrocarbon trap available<br />
Alltech hydrocarbon traps adsorb trace amounts of<br />
hydrocarbons and organics from your gas stream. Most<br />
traps are packed with activated charcoal and adsorb<br />
organic compounds larger than methane. Traps are<br />
available in a baseplate style that sits on the benchtop,<br />
a cartridge style that allows for easy replacement of the<br />
trap (requires baseplate unit to be ordered separately),<br />
and an in-line style that is freely supported on gas lines.<br />
Traps for CO2, and sulfur are also available.<br />
Baseplate Style Traps<br />
Cartridge Style Traps<br />
6463<br />
C) AT -Indicating Hydrocarbon Trap<br />
- The only indicating trap available for<br />
hydrocarbons<br />
- Changes from bright yellow to dark green<br />
when spent<br />
- Reduce costs by changing trap only when<br />
needed<br />
- Adsorbs organics larger than C2 down to<br />
A C C E S S O R I E S<br />
Purifiers<br />
In-Line Style Traps<br />
F) AT -Indicating Hydrocarbon Trap<br />
- Same features as cartridge format now available in<br />
the in-line style<br />
G) Activated Charcoal Trap<br />
- Two sizes available<br />
6579<br />
4843<br />
H) Hydrocarbon Trap<br />
- Economical<br />
- 250psig pressure rating<br />
I) Hi-EFF ® Organic Trap<br />
- Removes hydrocarbons and moisture<br />
- Indicating for moisture<br />
4848<br />
4843<br />
J) BIG Hydrocarbon Trap<br />
- Large 750cc size<br />
- Helium purged prior to shipment<br />
K) ALL-Pure Hydrocarbon Trap<br />
- Removes hydrocarbons to
Purifiers<br />
A C C E S S O R I E S<br />
Alltech Gas Purification<br />
Cartridge Systems<br />
• Replace spent purifiers without shutting down your<br />
system<br />
Alltech gas purification cartridges allow replacement<br />
of spent cartridges in seconds without shutting down<br />
your <strong>GC</strong> system. Simply pull the spent cartridge off the<br />
baseplate and<br />
push a new one<br />
into place. A<br />
knurled locking<br />
ring keeps<br />
the cartridge<br />
locked in place.<br />
Four different<br />
purification<br />
cartridges<br />
are available.<br />
Knurled<br />
locking ring<br />
Convenient cartridge baseplate<br />
automatically stops gas flow<br />
when changing cartridges<br />
Multiple cartridges and baseplates can be plumbed<br />
together to customize a gas purification system for your<br />
application. Order each cartridge separately below.<br />
Moisture Trap Cartridge - Filled with indicating<br />
Drierite ® and molecular sieve pellets to maximize<br />
moisture removal and to indicate when the cartridge<br />
requires refilling or replacement. A refill kit is available<br />
below.<br />
Organic Trap Cartridge - Removes non-methane<br />
hydrocarbons from your gas stream. A refill kit is<br />
available below.<br />
AT -Omni Cartridge - A multi-purpose cartridge<br />
filled with OXY-MAX and Hi-EFF ® Charcoal to effectively<br />
remove oxygen, moisture and hydrocarbons. AT -Omni<br />
cartridges are disposable.<br />
AT -Indicating Oxy Cartridge - Filled with OXY-MAX <br />
and indicating oxygen adsorbent to efficiently remove<br />
oxygen and small amounts of moisture. The indicating<br />
material shows a color change when the cartridge is<br />
saturated. AT -Indicating Oxy cartridges are disposable.<br />
GAS PURIFICATION CARTRIDGE SYSTEMS*<br />
ALL-Pure Gas Purifiers<br />
• One purifier removes multiple contaminants<br />
• Reduce impurities to low ppb levels<br />
ALL-Pure Gas Purifiers feature a unique proprietary<br />
broad spectrum adsorbent material that removes multiple<br />
contaminants with a single purifier. Replace three<br />
separate purifiers for oxygen, moisture, and hydrocarbons<br />
with a single ALL-Pure purifier. Purifiers are gas specific<br />
or choose purifiers specific for moisture, hydrocarbons or<br />
oxygen.<br />
ALL-Pure Specifications<br />
Dimensions: 400cc, 21"L x 1.5"o.d. (50.8cm x 3.8cm)<br />
Max Flow: 500mL/min<br />
Max. Pressure: 1000psig<br />
Max. Temp: 80°C<br />
Mounting: Purifier must be mounted in vertical position<br />
Purifier Selectivity and Purity Specifications<br />
ALL-PURE GAS PURIFIERS<br />
SULFUR<br />
COMPOUNDS<br />
4851<br />
NON-METHANE<br />
HYDROCARBONS<br />
PURIFIER CO CO2 O2 H2O<br />
Helium Purifier
A C C E S S O R I E S<br />
Purifiers<br />
AT -Multi-Purge II ®<br />
• Three traps conveniently mounted in one panel<br />
• Removes water, oxygen, and hydrocarbons<br />
• Easy wall mounting<br />
The AT -Multi Purge II ® is a high capacity, three<br />
stage gas purifying module that removes all common<br />
contaminates – moisture, hydrocarbons, and oxygen<br />
– from <strong>GC</strong> gas streams. It combines three high capacity<br />
traps (Hydro-Purge II ® , Hydrocarbon, and Oxy-Purge ® N)<br />
to permit longer, maintenance-free operation.<br />
The first stage of gas purification removes moisture<br />
from the gas stream with the Alltech Hydro-Purge II ® .<br />
It contains indicating molecular sieve that changes<br />
from blue to tan when saturated. Stage two removes<br />
hydrocarbon contamination from the gas stream<br />
with the Alltech Hydrocarbon trap. The final stage of<br />
purification removes oxygen from the gas stream with<br />
the Oxy-Purge ® N oxygen trap.<br />
An indicating Oxy-Trap can be added to the AT -<br />
Multi-Purge II ® for maximum column protection. It will<br />
monitor the performance of the oxygen trap and undergo<br />
a color change from tan to dark brown when spent<br />
indicating when the high capacity Oxy-Purge ® N requires<br />
replacement. Order separately under “<strong>Accessories</strong>” below.<br />
Each AT -Multi-Purge II ® is supplied with all internal<br />
plumbing and installation and operating instructions.<br />
AT -MULTI-PURGE II<br />
DESCRIPTION PART NO. PRICE<br />
AT -Multi-Purge II ®<br />
with 1/8" Fittings 14565<br />
with 1/4" Fittings 14564<br />
Replacement Parts<br />
Refill Kit for Hydro-Purge II ® 14637<br />
1/8" Hydrocarbon Trap 14634<br />
1/4" Hydrocarbon Trap 14633<br />
1/8" Oxy-Purge ® N 14636<br />
1/4" Oxy-Purge ® N 14635<br />
ACCESSORIES<br />
DESCRIPTION PART NO. PRICE<br />
1/4" Indicating Oxygen Trap* 4004<br />
* 1/8" reducing ferrules are supplied.<br />
© Copyright 2004 Alltech Associates, Inc.<br />
4853<br />
Gas Control/Purification<br />
Panels<br />
• Complete gas control and<br />
purification station<br />
• Operating pressures up to<br />
100psig<br />
• Allows safer remote<br />
placement of cylinders<br />
Alltech’s gas panels<br />
provide convenient control<br />
and purification of laboratory<br />
gases. The panels are<br />
supplied with valves, gauges,<br />
regulators, purifiers, and<br />
fittings that make installing<br />
Type A<br />
6250 6251<br />
Type B<br />
and maintaining gas purifiers easier. Their wall mount<br />
design conserves bench top space and allows you to<br />
easily view the status of your gas system. Panels can be<br />
used as individual stations or grouped together to form<br />
a gas control center for the entire lab. Each panel is<br />
ready to connect to 1/4" o.d. gas lines. Vespel ® reducing<br />
ferrules allow connection to 1/8" lines.<br />
Two types of panels are available. Type “A” includes<br />
an Alltech Gas Purifier that removes moisture, oil, small<br />
aliphatics, HCl, SO2, NO2, H2S, and CO2, and it measures<br />
29" x 4-5/8" x 3" . Type “B” includes an Alltech Gas<br />
Purifier and an Alltech Indicating Oxy-Trap that also<br />
removes oxygen in addition to the other contaminants,<br />
and measures 29" x 5-5/8" x 3". Both traps contain<br />
indicating adsorbents that allow you to visually<br />
determine when they require replacement.<br />
GAS<br />
GAS CONTROL/PURIFICATION PANELS<br />
TYPE A<br />
PART NO.<br />
PRICE<br />
REPLACEMENT PARTS<br />
TYPE B<br />
PART NO.<br />
Hydrogen 8150 8162<br />
Air 8152 —<br />
Oxygen 8154 —<br />
Helium 8156 8164<br />
Nitrogen 8158 8166<br />
Argon 8160 8168<br />
PRICE<br />
DESCRIPTION PART NO. PRICE<br />
In-Line Gas Purifier, 1/4" 8125<br />
Indicating Oxy-Trap 4004<br />
Regeneration Service for 4004 4014<br />
Refill Kit for 8125 8132<br />
Contact your Alltech office or distributor for current or local prices.<br />
407
Purifiers<br />
A C C E S S O R I E S<br />
SGT Super-Clean ® Filters<br />
Improve baselines, minimize interferences, and reduce MS<br />
maintenance<br />
• Remove impurities to deliver 99.9999% pure gas<br />
• Exchange filters in seconds, without introducing air into the system<br />
• Diffusion-proof with glass and metal construction<br />
• Pressure resistant up to 150psig (11 bar)<br />
These SGT Super-Clean ® filters can be used on all of your <strong>GC</strong> gas lines to deliver<br />
99.9999% pure gas. Filters are available for oxygen, moisture and hydrocarbons.<br />
The Combi filter removes both moisture and hydrocarbons. The Triple filter removes<br />
moisture, oxygen, and hydrocarbons and is available purged with Argon for standard<br />
applications or purged with Helium for MS applications.<br />
Filters feature a quick change baseplate/cartridge design. Cartridges can be<br />
exchanged within seconds, during analysis, and without tools. 1-,2-,3-, or 4-<br />
position baseplates are available and will accept any of the <strong>GC</strong> filter cartridges.<br />
Baseplates must be ordered separately (except for systems). Filter cartridge bundles<br />
include the most popular filters in one package. Various filter systems are available<br />
and include the appropriate baseplate.<br />
Not sure which filter you need?<br />
Contact Alltech Tech Support:<br />
Email: tech_service@alltechemail.com<br />
Online: www.alltechWEB.com<br />
Triple Filter F0301<br />
shown on baseplate<br />
(order separately).<br />
6516<br />
Capacities<br />
Specifications<br />
Maximum Flow:<br />
Efficiency:<br />
Maximum Pressure:<br />
Connectors:<br />
7.0L/min<br />
A C C E S S O R I E S<br />
Purifiers<br />
Purifier <strong>Accessories</strong><br />
Universal Mounting Panel<br />
• Mount up to 5 purifiers for easy monitoring and<br />
replacement<br />
• Pre-drilled for easy mounting<br />
• Fits most manufacturers’ purifiers<br />
This lightweight aluminum mounting panel will hold<br />
up to five purifiers. Pre-drilled holes are spaced at<br />
3⁄4" centers in five vertical rows to allow for maximum<br />
versatility. Mounting clips to accommodate purifiers<br />
from 7/8" to 2-1/2" o.d. are sold separately below.<br />
Panel measures 17"W x 24"H.<br />
In-Line Particulate Filter<br />
• Economically remove particulates from gas streams<br />
This brass in-line particulate filter is a convenient,<br />
inexpensive way to remove particulates from critical<br />
gas streams. Each unit includes one 10 micron filter<br />
cartridge. The maximum pressure rating is 500psig.<br />
4858<br />
IN-LINE PARTICULATE FILTERS<br />
DESCRIPTION PART NO. PRICE<br />
1/4" In-line Brass Filter 8052<br />
1/8" In-line Brass Filter 8054<br />
AT -Purifier Shield for In-Line Traps<br />
• Protect AT purifiers from damage<br />
This shield is compatible with the Alltech In-Line<br />
acrylic purifiers. The AT-Purifier Shield slips over your<br />
existing Alltech purifier, protecting the cartridge while<br />
still allowing visual monitoring of the contents of the<br />
trap.<br />
4854<br />
UNIVERSAL MOUNTING PANEL<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Universal Mounting Panel ea 7220<br />
Universal Mounting Clips<br />
Fits 7/8" to 1" o.d. Traps 2/pk 7221<br />
Fits 1-1/8" to 1-3/8" o.d. Traps 2/pk 7223<br />
Fits 1-3/8" to 1-5/8" o.d. Traps 2/pk 7225<br />
Fits 1-5/8" to 1-7/8" o.d. Traps 2/pk 7227<br />
Fits 2" to 2-1/2" o.d. Traps 2/pk 7229<br />
AT CARTRIDGE SHIELD<br />
DESCRIPTION PART NO. PRICE<br />
Shield for 120cc Purifier 81210<br />
4859<br />
Leaking?<br />
Ensure leak-free installation of<br />
your gas purifiers. See page<br />
397 for gas leak detectors.<br />
Make quick purifier connections!<br />
See page 421 for Quick-Connect Fittings.<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
409
Pressure Regulators<br />
A C C E S S O R I E S<br />
Alltech Regulators<br />
A) Dual Stage Economy<br />
Regulators<br />
These regulators are suitable for<br />
pressure control of general purpose<br />
laboratory gases with applications requiring constant<br />
pressure control and delivery regardless of supply<br />
pressure variations. Typical applications include<br />
purging, pressure testing, blanketing, and chamber<br />
pressurization.<br />
5244<br />
C) Single Stage Regulators<br />
These regulators are suitable for secondary<br />
pressure control of noncorrosive, high purity<br />
gases or as point of use pressure control in<br />
high purity gas distribution systems. Typical<br />
applications include point of use laboratory systems,<br />
gas supply purging, and bulk gas distribution systems.<br />
SINGLE STAGE<br />
DESCRIPTION CGA NO. PART NO. PRICE<br />
0-40psig (delivery pressure) — 81890<br />
0-120psig (delivery pressure) — 81891<br />
0-200psig (delivery pressure) — 81892<br />
5246<br />
DUAL STAGE ECONOMY<br />
DESCRIPTION CGA NO. PART NO. PRICE<br />
H2, Ar/Methane 350 8101<br />
O2 540 8102<br />
He, N2, Ar, Ne 580 8103<br />
Air 590 8104<br />
Air, Breathing Quality 346 8105<br />
D) Single Stage Liquid Cylinder<br />
Regulators<br />
These regulators are suitable for primary<br />
pressure control of gases supplied from<br />
cryogenic liquid cylinders. Typical<br />
applications include regulation of liquid<br />
nitrogen, oxygen, and carbon dioxide.<br />
5247<br />
B) Dual Stage High<br />
Purity Regulators<br />
These regulators are suitable<br />
for secondary pressure control of<br />
noncorrosive or high purity gases for applications<br />
requiring constant pressure control and delivery<br />
regardless of supply pressure variations. Typical<br />
applications include gas supply purging, gas system<br />
charging, fuel gas supply control, and calibrations gas<br />
control.<br />
DUAL STAGE HIGH PURITY<br />
DESCRIPTION CGA NO. PART NO. PRICE<br />
H2, Ar/Methane 350 8109<br />
He, N2, Ar, Ne 580 8111<br />
Need Cylinder Accesories?<br />
Alltech carries cylinder accessories.<br />
See page 390 for more information.<br />
5245<br />
SINGLE STAGE LIQUID CYLINDER<br />
DESCRIPTION CGA NO. PART NO. PRICE<br />
CO2, 0-40psig 320 81899<br />
N2, 0-40psig 580 81893<br />
O2, 0-40psig 540 81897<br />
CO2, 0-120psig 320 81900<br />
N2, 0-120psig 580 81894<br />
O2, 0-120psig 540 81898<br />
E) Panel Mount Regulators<br />
These regulators can also be used in-line.<br />
Order gauges and mounting nut separately.<br />
PANEL MOUNT<br />
DESCRIPTION CGA NO. PART NO. PRICE<br />
Panel Mount Regulator — 81896<br />
Panel Mounting Nut — 81895<br />
Pressure Gauges for Panel Mount Regulators<br />
0-30psig — 86800<br />
0-60psig — 86802<br />
0-100psig — 86804<br />
0-200psig — 86808<br />
5248<br />
410<br />
Specifications for Alltech Regulators<br />
A) DUAL STAGE ECONOMY B) DUAL STAGE HIGH PURITY C) SINGLE STAGE D) SINGLE STAGE LIQUID CYLINDER E) PANEL MOUNT<br />
Body: Forged Brass Chrome-plated forged brass Chrome-plated forged brass Chrome-plated forged brass Brass<br />
Bonnet: Brass-plated die cast zinc Chrome-plated die cast zinc Chrome-plated die cast zinc Chrome-plated die cast zinc Acetal Resin<br />
Diaphragm: PTFE -lined neoprene 316L Stainless Steel 316L Stainless Steel 316L Stainless Steel Nitrile<br />
Seat & Internal Seal: PTFE PTFE PTFE PTFE Acetal Resin<br />
Mas. Inlet Pressure: 3000psig (210 bar) 3000psig (210 bar) 3000psig (210 bar) 3000psig (210 bar) 400psig<br />
Delivery Press. Range: 0-120psig 0-120psig 0-40, 0-120, or 0-200psig 0-40 or 0-120psig —<br />
Delivery Press. Gauge: 0-20psig 0-200psig 0-60, 0-200, or 0-400psig 0-60 or 0-200psig Order Separately<br />
Cylinder Press. Gauge: 0-4000 psig 0-4000psig 0-4000psig 0-4000psig 0-4000psig<br />
Temperature Range: -40 to 60°C -40 to 60°C -40 to 60°C -40 to 60°C -34 to 65°C<br />
Gauges: 2-1/2" diameter brass 2-1/2" diameter brass 2-1/2" diameter brass 2-1/2" diameter brass Order Separately<br />
Ports: 1/4" FPT 1/4" FPT 1/4" FPT 1/4" FPT 1/8" FPT<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Gas Sampling<br />
Gas Sampling Bag Selection Guide<br />
FEP Gas Sampling Bags, 5mil<br />
TENSILE STRENGTH*<br />
FITTINGS AVAILABLE (BY ASTM D-882)<br />
Barbed on/off<br />
Septum Port<br />
Dual<br />
1/4" SS Fitting<br />
2N1 Combination<br />
2,500-3000psig<br />
(Note: This is NOT<br />
a burst pressure<br />
rating for the<br />
bag.)<br />
PERMEABILITY<br />
Gas<br />
CO2<br />
Hydrogen<br />
Nitrogen<br />
Oxygen<br />
Acetic Acid<br />
Vapor<br />
Acetone<br />
Benzene<br />
CCl4<br />
Ethanol<br />
Hexane<br />
Water<br />
Permeability**<br />
1670<br />
2200<br />
320<br />
750<br />
0.41<br />
Permeability***<br />
0.95<br />
0.64<br />
0.31<br />
0.69<br />
0.56<br />
0.45<br />
TEMPERATURE<br />
RANGE (°C) SAMPLE COMPATIBILITY ADVANTAGE<br />
-240 to 260 Inert and solvent<br />
resistant to virtually<br />
all chemicals except<br />
molten alkali metals,<br />
gaseous fluorine, complex<br />
halogenated compounds<br />
at elevated pressure and<br />
temperature<br />
Low permeability to<br />
liquids, gases, moisture<br />
and organic vapors;<br />
suitable for cryogenic use<br />
Tedlar® PVF, 2mil<br />
FITTINGS AVAILABLE<br />
Barbed on/off<br />
Septum Port<br />
Dual<br />
1/4" SS Fitting<br />
2N1 Combination<br />
TENSILE STRENGTH*<br />
(BY ASTM D-882)<br />
17,000-<br />
18,000psig (Note:<br />
This is NOT a<br />
burst pressure<br />
rating for the<br />
bag.)<br />
PERMEABILITY<br />
Gas<br />
CO2<br />
Hydrogen<br />
Nitrogen<br />
Oxygen<br />
Vapor<br />
Acetic Acid<br />
Acetone<br />
Benzene<br />
CCl4<br />
Ethyl Acetate<br />
Ethanol<br />
Hexane<br />
Water<br />
Permeability**<br />
11.1<br />
150<br />
0.25<br />
3.2<br />
Permeability***<br />
45<br />
10,000<br />
90<br />
50<br />
1.000<br />
35<br />
55<br />
180<br />
TEMPERATURE<br />
RANGE (°C) SAMPLE COMPATIBILITY ADVANTAGE<br />
-234 to 300 Recommended for<br />
analysis of non-corrosive<br />
gases, TCLP gases,<br />
CO, H2S, radon, and<br />
mercaptans; “Grab”<br />
sampling; preparation<br />
of calibration gas<br />
standards; gas blending;<br />
stack sampling; emission<br />
testing<br />
Lowest permeability of all<br />
types of bags; economical<br />
alternative to PTFE; easily<br />
cleaned and reused<br />
Cali-5-Bond 5.5mil (polyethylene, polyamide, aluminum foil, polyvinyl, chloride polyester)<br />
FITTINGS AVAILABLE<br />
2N1 Combination<br />
Barbed on/off<br />
Septum Port<br />
Fittings<br />
TENSILE STRENGTH*<br />
(BY ASTM D-882)<br />
PERMEABILITY<br />
TEMPERATURE<br />
RANGE (°C) SAMPLE COMPATIBILITY ADVANTAGE<br />
— — Max. 54 Designed specifically for<br />
collecting air samples;<br />
suitable for the storage<br />
and transportation of gas<br />
samples<br />
*Tensile strength is the maximum force required to rupture a one inch wide specimen. ** cc/(100in 2 )(24hrs)(atm/mil) *** gms/(100in 2 )(24hrs/mil)<br />
Opaque bag protects<br />
sample from UV<br />
degradation; bags may be<br />
purged with nitrogen or<br />
pure air and reused<br />
Alltech offers a large variety of gas sampling bag fittings. Consider the following when selecting a fitting:<br />
1. How will you collect the sample? What type of connection is available to connect to the bag?<br />
2. How will you need to access the sample once it is collected in the bag?<br />
3. Is your sample compatible with the fitting material?<br />
6644 6642 6738 6645 6643<br />
Nickel-plated<br />
Barbed On-Off Valve<br />
PTFE Septum Port Dual On-Off/Septum 1/4" SS Swagelok ® 2N1 Combination<br />
On-Off/Septum<br />
Need a syringe? See pages 55-71 for our<br />
complete selection of syringes.<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
411
Gas Sampling<br />
A C C E S S O R I E S<br />
Gas Sampling Bags<br />
Alltech Tedlar ® Gas Sampling Bags<br />
• High tensile strength resists puncture<br />
• Low permeability minimizes sample loss<br />
Alltech Tedlar® bags are manufactured from sturdy 2mil PVF<br />
film that is inert to a wide range of gases. Low permeability<br />
ensures the integrity of your sample and makes Tedlar® bags the<br />
ideal choice for off site analysis.<br />
6647<br />
NOMINAL SIZE<br />
VOLUME<br />
BARBED ON-OFF<br />
VALVE PART NO.<br />
PRICE<br />
ALLTECH TEDLAR® GAS SAMPLING BAGS<br />
SEPTUM PORT<br />
PART NO.<br />
PRICE<br />
DUAL ON-OFF/SEPTUM<br />
PORT PART NO.<br />
PRICE<br />
1/4" SS SWAGELOK ®<br />
PART NO.<br />
6" x 6" 0.6L 41021 41023 41025 41027<br />
6" x 10" 1.2L 41029 41031 41033 41035<br />
6" x 12" 1.5L 41037 41039 41041 41043<br />
9" x 9" 2L 41045 41047 41049 41051<br />
12" x 12" 5L 41053 41055 41057 41059<br />
12" x 19" 10L 41063 41065 41067 41069<br />
18" x 18" 16L 41071 41073 41075 41077<br />
24" X 24" 40L 41079 41081 41083 41085<br />
24" x 30" 56L 41087 41089 41091 41093<br />
24" x 36" 73L 41095 41097 41099 41032<br />
30" x 30" 80L 41034 41036 41038 41042<br />
PRICE<br />
Alltech FEP Gas Sampling Bags<br />
• 5mil thickness for durability<br />
• Manufactured and packaged under GLP conditions<br />
Alltech FEP bags have a 5mil film thickness making them<br />
suitable for harsh sampling conditions. Bags are chemically<br />
resistant to the most severe corrosives. Choose from 4 different<br />
port types.<br />
6646<br />
NOMINAL SIZE<br />
VOLUME<br />
BARBED ON-OFF<br />
VALVE PART NO.<br />
PRICE<br />
ALLTECH FEP GAS SAMPLING BAGS<br />
SEPTUM PORT<br />
PART NO.<br />
PRICE<br />
DUAL ON-OFF/SEPTUM<br />
PORT PART NO.<br />
PRICE<br />
1/4" SS SWAGELOK ®<br />
PART NO.<br />
6" x 6" 0.6L 41044 41046 41048 41052<br />
6" x 10" 1.2L 41054 41056 41058 41064<br />
6" x 12" 1.5L 41066 41068 41072 41074<br />
9" x 9" 2L 41076 41078 41082 41084<br />
12" x 12" 5L 41086 41088 41092 41094<br />
12" x 19" 10L 41106 41108 41109 41125<br />
18" x 18" 16L 41127 41129 41131 41133<br />
24" x 24" 40L 41135 41137 41139 41149<br />
24" x 30" 56L 41151 41153 41155 41157<br />
24" x 36" 73L 41126 41128 41132 41134<br />
30" x 30" 80L 41136 41138 41152 41154<br />
PRICE<br />
Replacement Parts<br />
REPLACEMENT PARTS FOR TEDLAR® AND FEP BAGS<br />
DESCRIPTION PART NO. PRICE<br />
Replacement Septa for Septa Port, 10/pk 41158<br />
1/4" PTFE No Hole Ferrules for 1/4" SS Fitting, 10/pk RF-400/0-T<br />
412<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Gas Sampling<br />
Gas Sampling Bags<br />
Combo Valve Gas Sampling Bags<br />
• On/off valve and septum in one fitting<br />
• Save with convenient multi-packs<br />
Cali-5-Bond 5-Layer Gas Sampling Bags<br />
• Non-permeable<br />
• Opaque to UV and visible light<br />
• Inert, flexible, tough and reusable<br />
6648 1651<br />
Combo valve gas sampling bags give the convenience<br />
and ease of a barbed on/off valve and a septum port<br />
combined into one fitting. The valve fitting features a<br />
3/16" stem, which is suitable for use with most 1/4"<br />
tubing, and a sampling port. Bags are available in<br />
Tedlar® and FEP as well as convenient multi-packs.<br />
COMBO VALVE GAS SAMPLING BAGS<br />
SIZE VOLUME PORT DESCRIPTION PART NO. PRICE<br />
Tedlar® Gas Sampling Bags<br />
7 x 7" 1L 2N1 41001<br />
9 x 9" 2L 2N1 41003<br />
9 x 12" 3L 2N1 41005<br />
12 x 12" 5L 2N1 41007<br />
12 x 19" 10L 2N1 41011<br />
12 x 21" 12L 2N1 41013<br />
18 x 24" 25L 2N1 41017<br />
FEP Gas Sampling Bags<br />
6 x 6" 0.6L 2N1 41002<br />
6 x 10" 1.2L 2N1 41004<br />
6 x 12" 1.5L 2N1 41006<br />
9 x 9" 2L 2N1 41008<br />
12 x 12" 5L 2N1 41012<br />
12 x 19" 10L 2N1 41016<br />
18 x 18" 16L 2N1 41018<br />
SIZE<br />
TEDLAR® COMBO VALVE MULTI-PACKS<br />
VOLUME<br />
PORT<br />
DESCRIPTION QTY PART NO. PRICE<br />
7 x 7" 1L 2N1 10 48001<br />
9 x 9" 2L 2N1 10 48003<br />
12 x 12" 5L 2N1 10 48007<br />
12 x 19" 10L 2N1 10 48011<br />
18 x 24" 25L 2N1 5 48017<br />
Cali-5-bond gas sampling bags are constructed<br />
from inert 5.5mil thick material made from five layers<br />
of film. The layers are comprised of an inner layer of<br />
high-density polyethylene, followed by polyamide, an<br />
aluminum foil barrier, a polyvinylidene chloride layer and<br />
an outer layer of polyester. These bags are specifically<br />
designed for air sampling and are suitable for the storage<br />
and transportation of gas samples.<br />
Cali-5-Bond bags are available in both pillow and<br />
snout shapes. The snout provides additional entry into<br />
the bag for flushing and sample collection.<br />
Bags are equipped with a barbed on-off valve and<br />
silicone septum for easy sampling and can be purged<br />
with nitrogen or pure air gas and reused.<br />
5-LAYER GAS SAMPLING BAGS<br />
NOMINAL SIZE VOLUME PORT DESCRIPTION PART NO. PRICE<br />
Snout-Shaped Gas Sampling Bags<br />
8 x 15" 2L Barbed Valve 1" Septa 4150<br />
8 x 27" 5L Barbed Valve 1" Septa 4152<br />
16 x 16" 10L Barbed Valve 1" Septa 4186<br />
16 x 29" 22L Barbed Valve 1" Septa 4154<br />
23.5 x 28" 44L Barbed Valve 1" Septa 4156<br />
Pillow-Shaped Gas Sampling Bags<br />
8 x 8" 1L Barbed Valve 1" Septa 4188<br />
8 x 11" 2L Barbed Valve 1" Septa 4190<br />
16 x 19" 15L Barbed Valve 1" Septa 4192<br />
23.5 x 31" 60L Barbed Valve 1" Septa 4194<br />
31 x 31.5" 90L Barbed Valve 1" Septa 4196<br />
31 x 55" 170L Barbed Valve 1" Septa 4198<br />
Have a Question about Your Order?<br />
Contact Alltech Customer Service:<br />
Online Ordering 24 hours a day:<br />
www.alltechWEB.com<br />
Email: alltech@alltechemail.com<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
413
Gas Sampling<br />
A C C E S S O R I E S<br />
Gas Sampling <strong>Accessories</strong><br />
Gas Sampling Bulb with Septum Ports<br />
• PTFE stop cocks for increased compatibility<br />
GAS SAMPLING BULBS<br />
DESCRIPTION PART NO. PRICE<br />
125mL, PTFE Stopcock 7012<br />
250mL, PTFE Stopcock 7013<br />
500mL, PTFE Stopcock 7011<br />
1000mL, PTFE Stopcock 7066<br />
Replacement Septa, 12/pk 7000<br />
Gas Sampling Bulb with Twist-Lock<br />
Stopcocks<br />
• Unique twist-lock stopcocks<br />
• PTFE outlet tube connectors<br />
GAS SAMPLING BULBS<br />
DESCRIPTION PART NO. PRICE<br />
125mL, PTFE Stopcock 6950<br />
250mL, PTFE Stopcock 6952<br />
500mL, PTFE Stopcock 6954<br />
Replacement Septa, 10/pk 6900<br />
4663<br />
4664<br />
Vacuum Sampler<br />
• No external pump required<br />
• Reusable<br />
These evacuated 280mL vacuum samplers<br />
are fitted with a unique septum port and<br />
needle guide through which the container is<br />
filled and samples removed. A 4" long needle<br />
is supplied with each vacuum sampler (2<br />
needles with the package of 12 samplers).<br />
VACUUM SAMPLER<br />
DESCRIPTION PART NO. PRICE<br />
280mL (1 needle), ea 8020<br />
280mL (2 needles) 12/pk 8022<br />
Replacement Septa, 12/pk 8015<br />
Can Piercing Unit<br />
Can piercer allows small samples to be<br />
taken without significantly disturbing the<br />
equilibrium conditions in the container.<br />
The piercer can be affixed to the side of<br />
a round container with supplied steel<br />
straps.<br />
CAN PIERCING UNIT<br />
6310<br />
4667<br />
(Can not included)<br />
DESCRIPTION PART NO. PRICE<br />
Can Piercer 8013<br />
Replacement Septa, 12/pk 8015<br />
Replacement Gaskets, 12/pk 8016<br />
Gas Sampling Bulb with Injection Port &<br />
Valve Stopcocks<br />
• Stored sample contacts only glass and PTFE<br />
• Suitable for vacuum or pressure<br />
• Semi-needle valve control<br />
Gas and Vapor Sampler<br />
• Sample bags are removable and resealable<br />
Collect samples in resealable 200cc<br />
multilayer bags. Simply evacuate the can is ter<br />
using the supplied aspirator bulb. The bags can<br />
be re moved for stor age or ship ment, free ing<br />
the canister for fur ther sam pling. Ten bags are<br />
in clud ed with each kit.<br />
4668<br />
4665<br />
414<br />
GAS SAMPLING BULBS<br />
DESCRIPTION PART NO. PRICE<br />
125mL 6940<br />
250mL 6942<br />
500mL 6944<br />
13-425 Open-Hole Caps, 100/pk 73090<br />
TFE/Silicone Liners, 100/pk 98123<br />
© Copyright 2004 Alltech Associates, Inc.<br />
GAS AND VAPOR SAMPLER<br />
DESCRIPTION PART NO. PRICE<br />
Gas and Vapor Sampler Kit 4182<br />
Replacement Bags, 10/pk 4184<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Ferrules<br />
<strong>GC</strong> Ferrule Selection<br />
PTFE Ferrules<br />
PTFE ferrules are completely inert and an economical<br />
choice. They have an upper temperature limit of 250°C.<br />
PTFE ferrules conform well to the shape of the column<br />
upon compression and can be reused if handled carefully.<br />
Graphite Ferrules<br />
These 99.95% pure graphite ferrules can be used at<br />
temperatures up to 450°C without producing bleed or<br />
decomposition products. The one-piece design requires<br />
no back ferrules. Graphite ferrules are very soft and<br />
conform well to the column on compression. These<br />
ferrules can be reused as long as care is taken not to<br />
overtighten them.<br />
Vespel ® Ferrules<br />
Vespel® ferrules do not cold flow, are easily reusable,<br />
and withstand temperature up to 350°C. At high<br />
temperatures, Vespel® may adhere to glass or metal.<br />
Vespel ® /Graphite Ferrules<br />
Composites of Vespel ® and graphite combine the<br />
advantages of the two materials. They are less likely to<br />
adhere to the column than Vespel® but are more durable<br />
than graphite. Ferrules are easy to reuse and stable at<br />
temperatures to 400°C.<br />
Two types of composites are available. The VG1<br />
composite is 85% Vespel ® /15% graphite and suitable for<br />
all-purpose applications. The VG2 type is 60% Vespel®/<br />
40% graphite and exhibits added lubricity.<br />
Ferrule Properties<br />
MATERIAL TEMP. LIMIT REUSABILITY RESEALING PROPERTIES SUITABILITY FOR GLASS TEMP. PROG.<br />
PTFE 250°C Good Excellent Excellent No<br />
Graphite 450°C Good Excellent Excellent Yes<br />
Vespel® 350°C+ Excellent Good Good Yes<br />
VG1 400°C Excellent Good Excellent Yes<br />
VG2 400°C Excellent Good Excellent Yes<br />
What ferrule type do you need?<br />
FERRULE TYPE<br />
0.4mm Hole:<br />
0.5mm Hole:<br />
0.8mm Hole:<br />
NO-HOLE:<br />
2-HOLE:<br />
USE FOR:<br />
Capillaries with i.d. of 0.10-0.25mm<br />
Capillaries with i.d. of 0.28-0.35mm<br />
Capillaries with i.d. of 0.45-0.53mm<br />
As plugs, or drill for special needs<br />
Connecting 2 pieces of capillary tubing<br />
or columns to the same fitting end<br />
PTFE AND GRAPHITE FERRULES<br />
DESCRIPTION FITTING SIZE TUBING SIZE QTY PTFE PART NO. PRICE GRAPHITE PART NO. PRICE<br />
Straight Ferrules<br />
1" 1" 2 — — 14361<br />
7/8" 7/8" 2 — — 14360<br />
3/4" 3/4" 2 — — 14358<br />
5/8" 5/8" 2 — — 14357<br />
Used when 1/2" 1/2" 10 — — SF-800-G<br />
the tubing 3/8" 3/8" 10 SF-600-T SF-600-G<br />
o.d. matches<br />
1/4" 1/4" 10 SF-400-T SF-400-G<br />
the nominal<br />
size of the<br />
3/16" 3/16" 10 SF-300-T SF-300-G<br />
fitting being 1/8" 1/8" 10 SF-200-T SF-200-G<br />
used.<br />
1/16" 1/16" 10 SF-100-T SF-100-G<br />
Reducing Ferrules<br />
1/4" 1/16" 10 RF-400/100-T RF-400/100-G<br />
1/4" 0.8mm 10 — — RF-400/0.8-G<br />
1/4" 1/8" 10 RF-400/200-T RF-400/200-G<br />
1/4" 3/16" 10 RF-400/300-T 14327<br />
1/4" 4mm 10 — — 14384<br />
Used when<br />
the tubing<br />
o.d. is smaller<br />
than the<br />
nominal<br />
size of the<br />
fittings.<br />
1/4" 6mm 10 RF-400/6MM-T RF-400/6MM-G<br />
1/8" 1/16" 10 RF-200/100-T RF-200/100-G<br />
1/8" 1.2mm 10 — — 14326<br />
1/8" 1.0mm 10 — — 14311<br />
1/8" 0.8mm 10 — — RF-200/0.8-G<br />
1/8" 0.5mm 10 — — RF-200/0.5-G<br />
1/8" 0.4mm 10 — — RF-200/0.4-G<br />
1/8" 1.2mm 10 — — 14305<br />
1/16" 1.0mm 10 — — RF-100/1.0-G<br />
1/16" 0.8mm 10 — — RF-100/0.8-G<br />
1/16" 0.5mm 10 — — RF-100/0.5-G<br />
1/16" 0.4mm 10 — — RF-100/0.4-G<br />
1/16" 0.3mm 10 — — 14308<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
415
Ferrules<br />
A C C E S S O R I E S<br />
PTFE AND GRAPHITE FERRULES (CONT’D)<br />
DESCRIPTION FITTING SIZE TUBING SIZE QTY PTFE PART NO. PRICE GRAPHITE PART NO. PRICE<br />
HP/Agilent Short Ferrules<br />
1/16" 1.2mm 10 — — 14370<br />
1/16" 1.0mm 10 — — 14325<br />
1/16" 0.8mm 10 — — 14324<br />
1/16" 0.5mm 10 — — 14323<br />
1/16" 0.4mm 10 — — 14322<br />
1/16" 0.3mm 10 — — 14321<br />
Two-Hole Ferrules<br />
1/8" 0.8mm 10 — — 14334<br />
1/8" 0.5mm 10 — — 14307<br />
1/16" 0.5mm 10 — — 14330<br />
No-Hole Ferrules<br />
3/8" 10 — 14332<br />
1/4" 10 RF-400/0-T 14328<br />
1/8" 10 RF-200/0-T 14314<br />
1/16" 10 RF-100/0-T 14310<br />
Graphite Ferrules for HP/Agilent Nuts<br />
0.5mm 10 — — 1547901<br />
1.0mm Hole 10 — — 1548001<br />
DESCRIPTION<br />
FITTING<br />
SIZE TUBING SIZE QTY<br />
VESPEL ® AND VESPEL ® /GRAPHITE FERRULES<br />
VESPEL ®<br />
PART NO.<br />
PRICE<br />
VG1<br />
PART NO.<br />
PRICE<br />
VG2<br />
PART NO.<br />
Straight Ferrules<br />
1/4" 1/4" 10 SF-400-V SF-400-VG1 SF-400-VG2<br />
1/4" 1/4" 10 15449* 15449* 15451*<br />
1/8" 1/8" 10 SF-200-V SF-200-VG1 SF-200-VG2<br />
1/8" 1/8" 10 — — 15450* 15452*<br />
1/16" 1/16" 10 SF-100-V SF-100-VG1 SF-100-VG2<br />
Reducing Ferrules<br />
1/4" 6mm 10 RF-400/6MM-V 400/6MM-VG1 400/6MM-VG2<br />
1/4" 3/16" 10 RF-400/300-V 400/300-VG1 400/300-VG2<br />
1/4" 1/8" 10 RF-400/200-V 400/200-VG1 400/200-VG2<br />
1/4" 1/16" 10 RF-400/100-V 400/100-VG1 400/100-VG2<br />
1/4" 0.8mm 10 — — 400/0.8-VG1 400/0.8-VG2<br />
1/8" 1/16" 10 RF-200/100-V 200/100-VG1 200/100-VG2<br />
1/8" 0.8mm 10 — — 200/0.8-VG1 200/0.8-VG2<br />
1/8" 0.5mm 10 — — 200/0.5-VG1 200/0.5-VG2<br />
1/8" 0.4mm 10 — — 200/0.4-VG1 200/0.4-VG2<br />
1/16" 1.0mm 10 RF-100/1.0-V 100/1.0-VG1 100/1.0-VG2<br />
1/16" 0.9mm 10 RF-100/0.9-V 100/0.9-VG1 100/0.9-VG2<br />
1/16" 0.8mm 10 RF-100/0.8-V 100/0.8-VG1 100/0.8-VG2<br />
1/16" 0.5mm 10 RF-100/0.5-V 100/0.5-VG1 100/0.5-VG2<br />
1/16" 0.4mm 10 RF-100/0.4-V 100/0.4-VG1 100/0.4-VG2<br />
1/16" 0.3mm 10 — — 100/0.3-VG1 — —<br />
No-Hole Ferrules<br />
1/4" — 10 RF-400/0-V 400/0-VG1 400/0-VG2<br />
1/8" — 10 RF-200/0-V 200/0-VG1 200/0-VG2<br />
1/16" — 10 RF-100/0-V 100/0-VG1 100/0-VG2<br />
Two-Hole Ferrules<br />
1/16" 0.5mm 10 — — 15486 15488<br />
1/16" 0.4mm 10 — — 15481 15487<br />
* Equivalent to Parker one-piece metal ferrule.<br />
PRICE<br />
416<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Fittings<br />
Fittings Selection Guide<br />
To determine the size of a nut or female pipe thread, compare it to the silhouettes below. To determine the size<br />
of a ferrule, measure its inside diameter. Please note that tubing fitting sizes are based on the outside diameter of<br />
the tube, while pipe thread fitting sizes are based on the inside dimension of the pipe. Pipe and tubing fittings are<br />
not interchangeable.<br />
Tubing Nut Sizes<br />
1/16" 1/8" 3/16" 1/4" 3/8" 1/2"<br />
0127<br />
Female Pipe Thread Connectors<br />
Tubing<br />
Tubing<br />
* Silhouettes shown at actual size<br />
Parker Fittings<br />
1/8" FPT<br />
1/8" (6-2-GBG) 1/4" FPT 3/8" FPT 1/2" FPT<br />
5767<br />
Parker fittings are available in two forms: the CPI one-piece ferrule and the A-Lok two piece ferrule. Most parts<br />
are available in brass or stainless steel and should be matched to the tubing, particularly in thermal applications.<br />
PARKER FITTINGS<br />
DESCRIPTION DIMENSIONS QTY<br />
Nuts<br />
Ferrules<br />
CPI<br />
Tees<br />
A-LOK<br />
© Copyright 2004 Alltech Associates, Inc.<br />
A-LOK<br />
BRASS<br />
PART NO.<br />
PRICE<br />
CPI<br />
BRASS<br />
PART NO. PRICE QTY<br />
A-LOK<br />
SS<br />
PART NO.<br />
PRICE<br />
CPI<br />
SS<br />
PART NO.<br />
1/16" 10/pk 11600 14057 10/pk 11700 141575<br />
1/8" 10/pk 11601 14058 10/pk 11701 14158<br />
3/16" 10/pk 11602 60000 10/pk 11702 61000<br />
1/4" 10/pk 11603 14059 10/pk 11703 14159<br />
3/8" 10/pk 11604 60002 10/pk 11704 610025<br />
1/2" 10/pk 11605 600045 5/pk 11705 610045<br />
1/16" 10/pk 11606 14060 10/pk 11706 141605<br />
1/8" 10/pk 11607 14061 10/pk 11707 14161<br />
3/16" 10/pk 11608 60006 10/pk 11708 61006<br />
1/4" 10/pk 11609 14062 10/pk 11709 14162<br />
3/8" 10/pk 11610 60008 10/pk 11710 610085<br />
1/2" 5/pk 11611 600105 5/pk 11711 610105<br />
1/16" ea 11612 14075 ea 11712 14175<br />
1/8" ea 11613 14053 ea 11713 14176<br />
3/16" ea 11614 60012 ea 11714 61012<br />
1/4" ea 11615 14077 ea 11715 14177<br />
3/8" ea 11616 60014 ea 11716 61014<br />
1/2" ea 11617 60016 ea 11717 61016<br />
PRICE<br />
Contact your Alltech office or distributor for current or local prices.<br />
417
Fittings<br />
A C C E S S O R I E S<br />
PARKER FITTINGS (CONT'D)<br />
DESCRIPTION DIMENSIONS QTY<br />
Unions<br />
Reducing Unions<br />
Capillary Union<br />
A-LOK<br />
BRASS<br />
PART NO.<br />
PRICE<br />
CPI<br />
BRASS<br />
PART NO. PRICE QTY<br />
A-LOK<br />
SS<br />
PART NO.<br />
PRICE<br />
CPI<br />
SS<br />
PART NO.<br />
1/16" ea 11618 14063 ea 11718 14163<br />
1/8" ea 11619 14065 ea 11719 14165<br />
3/16" ea 11620 60018 ea 11720 61018<br />
1/4" ea 11621 14068 ea 11721 14168<br />
3/8" ea 11622 60020 ea 11722 61020<br />
1/2" ea 11623 60022 ea 11723 61022<br />
1/8" to 1/16" ea 11624 14064 ea 11724 14164<br />
3/16" to 1/8" ea 11625 60024 ea 11725 61024<br />
1/4" to 1/16" ea 11626 60026 ea 11726 14166<br />
1/4" to 1/8" ea 11627 60028 ea 11727 61028<br />
1/4" to 3/16" ea 11628 14067 ea 11728 14167<br />
3/8" to 1/16" ea — — — — ea 11729 14174<br />
3/8" to 1/4" ea 11630 60030 ea 11730 61030<br />
1/16" ea — — — — ea — 28812<br />
PRICE<br />
418<br />
Female Pipe Thread Connectors (Tube to FPT)<br />
1/8" to 1/8" FPT ea 11800 60048 ea 11750 61048<br />
1/8" to 1/4" FPT ea 11801 14071 ea 11751 61084<br />
1/4" to 1/8" FPT ea 11802 60050 ea 11752 61050<br />
1/4" to 1/4" FPT ea 11803 14072 ea 11753 61086<br />
3/16" to 1/8" FPT ea 11804 60052 ea 11754 61052<br />
3/8" to 1/8" 6-2-GBZ ea 11805 60054 ea 11755 61054<br />
3/8" to 1/4" FPT ea 11806 60056 ea 11756 61056<br />
Male Pipe Thread Connectors (Tube to MPT)<br />
1/16" to 1/16" MPT ea 11632 60034 ea 11732 61034<br />
1/16" to 1/8" MPT ea 11633 60036 ea 11733 61036<br />
1/8" to 1/8" MPT ea 11634 60038 ea 11734 61038<br />
1/8" to 1/4" MPT ea 11635 60039 ea 11735 61039<br />
3/16" to 1/8" MPT ea 11636 60040 ea 11736 61040<br />
1/4" to 1/8" MPT ea 11637 60042 ea 11737 61042<br />
3/8" to 1/8" MPT ea 11638 60044 ea 11738 61044<br />
1/4" to 1/4" MPT ea 11639 14069 ea 11739 61082<br />
3/8" to 1/4" MPT ea 11640 60046 ea 11740 61046<br />
Tube End Connectors (Reducers)<br />
1/16" to 1/8" tube ea 11807 60058 ea 11757 61058<br />
1/16" to 1/4" tube ea — — — — ea 11758 61059<br />
1/8" to 1/4" tube ea 11809 60060 ea 11759 61060<br />
1/8" to 3/16" tube ea 11810 60062 ea 11770 61062<br />
3/16" to 1/4" tube ea 11811 4052 ea 11771 61064<br />
1/4" to 1/8" tube ea 11812 14073 ea 11772 14169<br />
1/4" to 3/8" tube ea 11813 60066 ea 11773 61066<br />
3/8" to 1/4" tube ea 11814 60068 ea 11774 61068<br />
Caps<br />
1/16" ea 11815 14047 ea 11835 14151<br />
1/8" ea 11816 14051 ea 11836 14152<br />
3/16" ea 11817 60070 ea 11837 61070<br />
1/4" ea 11818 14052 ea 11838 14153<br />
3/8" ea 11819 60072 ea 11839 61072<br />
1/2" ea 11820 60074 ea 11840 61074<br />
Plugs<br />
1/16" ea 11821 14054 ea 11841 14154<br />
1/8" ea 11822 14055 ea 11842 14155<br />
3/16" ea 11823 60076 ea 11843 61076<br />
1/4" ea 11824 14066 ea 11844 14156<br />
3/8" ea 11825 60078 ea 11845 61078<br />
1/2" ea 11826 60080 ea 11846 61080<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Fittings<br />
SWAGELOK ® Tube Fittings<br />
SWAGELOK® Tube Fittings provide a leak-proof,<br />
torque-free seal at all tubing connections and eliminate<br />
costly, hazardous leaks in instrumentation and process<br />
tubing.<br />
All the action in the fitting moves along the tube<br />
axially instead of with a rotary motion. Since no torque<br />
is transmitted from the fitting to the tubing, there is no<br />
initial strain which might weaken the tubing.<br />
CAUTION: Do not mix or<br />
interchange parts of tube<br />
fittings made by other<br />
manufacturers with SWAGELOK®<br />
tube fitting parts.<br />
SWAGELOK® FITTINGS<br />
DESCRIPTION DIMENSIONS QTY BRASS PART NO. PRICE QTY<br />
Nuts<br />
Male Nut<br />
STAINLESS STEEL<br />
PART NO.<br />
1/16" 10 55002 10 55199<br />
1/8" 10 55003 10 55193<br />
3/16" 10 55004 10 55194<br />
1/4" 10 55005 10 55195<br />
1/16" ea 55084 ea 55184<br />
PRICE<br />
Front Ferrules<br />
Back Ferrules<br />
Union (Low Dead Volume)<br />
1/16" 10 55006 10 55196<br />
1/8" 10 55007 10 55197<br />
3/16" 10 55008 10 55198<br />
1/4" 10 55013 10 55093<br />
1/16" 10 55014 10 55094<br />
1/8" 10 55015 10 55095<br />
3/16" 10 55016 10 55096<br />
1/4" 10 55017 10 55097<br />
1/16" ea 55001 ea 55101<br />
Unions<br />
Bulkhead Unions<br />
Reducing Unions<br />
1/16" ea 55009 ea 55109<br />
1/8" ea 55010 ea 55110<br />
3/16" ea 55011 ea 55114<br />
1/4" ea 55012 ea 55112<br />
1/16" ea 51017 ea 55117<br />
1/8" ea 55018 ea 55118<br />
3/16" ea 55019 ea 55119<br />
1/4" ea 55020 ea 55120<br />
1/8" to 1/16" ea 55021 ea 55121<br />
3/16" to 1/16" ea 55022 ea 55122<br />
3/16" to 1/8" ea 55023 ea 55123<br />
1/4" to 1/16" ea 55024 ea 55124<br />
1/4" to 1/8" ea 55025 ea 55125<br />
1/4" to 3/16" ea 55026 ea 55126<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
419
Fittings<br />
A C C E S S O R I E S<br />
SWAGELOK® FITTINGS (CONT’D)<br />
DESCRIPTION DIMENSIONS QTY BRASS PART NO. PRICE QTY<br />
Female Pipe Thread Connectors (Tube to FPT )<br />
STAINLESS STEEL<br />
PART NO.<br />
1/8" to 1/8" FPT ea 55046 ea 55146<br />
1/8" to 1/4" FPT ea 55047 ea 55147<br />
3/16" to 1/8" FPT ea 55048 ea 55148<br />
1/4" to 1/8" FPT ea 55049 ea 55149<br />
1/4" to 1/4" FPT ea 55050 ea 55150<br />
1/4" to 3/8" FPT ea 55051 ea 55151<br />
1/4" to 1/2" FPT ea 55052 ea 55152<br />
Male Pipe Thread Connectors (Tube to MPT)<br />
1/16" to 1/16" MPT ea 55033 ea 55133<br />
1/16" to 1/8" MPT ea 55034 ea 55134<br />
1/8" to 1/16" MPT ea 55035 ea 55135<br />
1/8" to 1/8" MPT ea 55036 ea 55136<br />
1/8" to 1/4" MPT ea 55037 ea 55137<br />
1/8" to 3/8" MPT ea 55038 ea 55138<br />
3/16" to 1/8" MPT ea 55039 ea 55139<br />
3/16" to 1/4" MPT ea 55040 ea 55140<br />
1/4" to 1/16" MPT ea 55041 ea 55141<br />
1/4" to 1/8" MPT ea 55042 ea 55142<br />
1/4" to 1/4" MPT ea 55043 ea 55143<br />
1/4" to 3/8" MPT ea 55044 ea 55144<br />
1/4" to 1/2" MPT ea 55045 ea 55145<br />
Tees<br />
1/16" ea 55027 ea 55127<br />
1/8" ea 55028 ea 55128<br />
3/16" ea 55029 ea 55129<br />
1/4" ea 55030 ea 55130<br />
Crosses<br />
1/8" ea 55031 ea 55131<br />
PRICE<br />
1/4" ea 55032 ea 55132<br />
Caps<br />
Plugs<br />
1/16" ea 55085 ea 55185<br />
1/8" ea 55086 ea 55186<br />
3/16" ea 55087 ea 55187<br />
1/4" ea 55088 ea 55188<br />
1/16" ea 55089 ea 55189<br />
1/8" ea 55090 ea 55190<br />
3/16" ea 55091 ea 55191<br />
1/4" ea 55092 ea 55192<br />
Need Tubing?<br />
See pages 422-424 for<br />
a complete selection of<br />
stainless steel, metal, and<br />
polymeric tubing.<br />
Need Technical Assistance?<br />
Contact Alltech Tech Support:<br />
Email: tech_service@alltechemail.com<br />
Online: www.alltechWEB.com<br />
420<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Fittings<br />
Specialty Fittings<br />
Brass Quick-Connects<br />
PFA Fittings<br />
PFA fittings offer superior chemical resistance. The<br />
one-piece ferrule and nut assembly allows for easy<br />
tubing connections. Maximum temperature rating<br />
is 250°C. Order a grooving tool (to groove tubing)<br />
separately below to achieve maximum pressure rating of<br />
125psig.<br />
PFA FITTINGS<br />
DESCRIPTION SIZE QTY PART NO. PRICE<br />
Ferrule Nut<br />
1/16" 5 45700<br />
1/8" 5 45701<br />
1/4" 5 45702<br />
Union<br />
1/16" 2 45715<br />
1/8" 2 45716<br />
1/4" 2 45717<br />
Reducing Union<br />
1/8"-1/16 2 45720<br />
1/4"-1/8" 2 45721<br />
Use Quick-Connects where gas lines are frequently<br />
broken and reassembled for convenient handling and<br />
to avoid air contamination in the gas line. Both ends<br />
of the fitting are completely shut off when the ends<br />
are separated and flow is automatically started when<br />
recoupled. Fittings are constructed of brass with Buna-<br />
N® seals. Maximum coupled pressure is 3000psig.<br />
SS Quick-Connects<br />
BRASS QUICK-CONNECTS<br />
DESCRIPTION PART NO. PRICE<br />
1/8" 7088<br />
1/4" 7089<br />
4855<br />
Tee<br />
Grooving Tool<br />
1/16" ea 45725<br />
1/8" ea 45726<br />
1/4" ea 45727<br />
1/8" ea 45746<br />
1/4" ea 45747<br />
These quick connects are 100% helium leak tested for<br />
optimum performance. They feature leak-tight Viton ®<br />
o-ring seals with a temperature range of -29 to 204°C.<br />
Simple push-pull action connects and disconnects lines<br />
without leakage. Fittings are rated for 3000psig when<br />
coupled.<br />
6693<br />
Wrench-Free <strong>GC</strong> Fittings<br />
• Special reusable ferrules<br />
• Star knob grip seals<br />
finger tight<br />
These fittings provide leakfree<br />
connections without the use of wrenches.<br />
The easy-grip star knob is designed for use with<br />
bulky, heat resistant gloves. A special graphite ferrule<br />
with a stainless steel sleeve is provided with the 1/4"<br />
kit; a specially designed Vespel®/Graphite ferrule is<br />
provided with the 1/8" kit (Both sizes can be used at<br />
temperatures up to 400°C.).<br />
5077<br />
SS QUICK-CONNECTS<br />
DESCRIPTION PART NO. PRICE<br />
1/8" 7092<br />
1/4" 7093<br />
PTFE Tape<br />
Use PTFE tape for a dry thread<br />
lubricant and sealant when making<br />
pipe thread (NPT) connections.<br />
Temperature limit is 200˚C.<br />
WRENCH-FREE <strong>GC</strong> FITTINGS<br />
DESCRIPTION PART NO. PRICE<br />
1/4" Wrench-Free<br />
Fitting Kit (2 Fittings, 4 Ferrules) 32004<br />
Repl. Ferrules, 5/pk 32002<br />
1/8" Wrench-Free<br />
Fitting Kit (2 Fittings, 4 Ferrules) 32006<br />
Repl. Ferrules, 5/pk 32008<br />
© Copyright 2004 Alltech Associates, Inc.<br />
PTFE TAPE<br />
DESCRIPTION QTY PART NO. PRICE<br />
1/2" x 260"L ea 3226<br />
1/2" x 260"L 12 Rolls 3227<br />
Contact your Alltech office or distributor for current or local prices.<br />
5078<br />
421
Tubing<br />
A C C E S S O R I E S<br />
Choosing a Tubing Material<br />
A number of options are available for packed column tubing. The most inert material is glass, which should<br />
be used for active compounds. Glass-lined tubing and AT-steel provide the inert surface of glass combined<br />
with the mechanical strength of a metal column.<br />
Metal tubing provides an economical and rugged column for suitable application. Passivated nickel tubing<br />
can frequently be used with active compounds such as phenols and amines. Stainless steel tubing is<br />
recommended for hydrocarbon, fixed gas, and solvent analyses where column inertness is less of a concern.<br />
PTFE tubing is extremely inert, but due to temperature limitations and poor column efficiency, PTFE is<br />
generally only recommended for the analysis of corrosive gases which are too reactive for glass.<br />
Stainless Steel Tubing<br />
AT Steel - Activity Tested Steel Tubing<br />
Delivers the Strength of Stainless Steel and the Inertness of Deactivated Fused Silica<br />
• Flexible, and strong • Maximum temperature limit of 340°C to 350°C<br />
A combination of chemical vapor deposition techniques and silicone chemistries transform<br />
durable stainless steel tubing into a chromatographically inert material. AT Steel activity<br />
tested steel tubing is suitable for sample loops, transfer lines, capillary and packed <strong>GC</strong> columns.<br />
AT -Steel may be cut with standard tubing cutters or high speed wheel cutters and can be<br />
rinsed with common solvents to remove particulates and contamination that have built up<br />
during use. To ensure a truly inert pathway, use AT -Steel treated fittings. Sold separately below.<br />
5105<br />
AT STEEL TUBING<br />
I.D. 6FT LENGTH PART NO. PRICE 25FT LENGTH PART NO. PRICE 50FT LENGTH PART NO. PRICE 100FT LENGTH PART NO. PRICE<br />
1/32" o.d. Tubing<br />
0.021" 11085 11086 11087 11088<br />
1/16" o.d. Tubing<br />
0.010" 11060 11061 11062 11063<br />
0.020" 11064 11065 11066 11067<br />
0.030" 11068 11069 11070 11071<br />
0.040" 11072 11073 11074 — —<br />
1/8" o.d. Tubing<br />
0.085" 11076 11077 11078 — —<br />
1/4" o.d. Tubing<br />
0.210" 11092 11093 — — — —<br />
AT -STEEL UNIONS<br />
DESCRIPTION PART NO. PRICE<br />
1/8" - 1/16 Reducing Union 11080<br />
1/16" Union 11081<br />
1/8" Union 11082<br />
Hi-EFF ® Grade Stainless Steel Tubing<br />
• Acetone washed to remove residual contaminants<br />
AT -STEEL TEES<br />
DESCRIPTION PART NO. PRICE<br />
1/16" Tee 11083<br />
1/8" Tee 11084<br />
Fittings are Parker A-Lok fittings with two-piece ferrules that have been chemically<br />
modified for improved inertness.<br />
HI-EFF ® Stainless Steel tubing meets the exact specification required to fabricate <strong>GC</strong><br />
columns. Tubing is specially tempered for easy bending. Type 304 is the most commonly used<br />
for <strong>GC</strong>. Type 316 offers more corrosion resistance.<br />
422<br />
© Copyright 2004 Alltech Associates, Inc.<br />
HI-EFF® TUBING<br />
O.D. I.D. PER FT* PART NO. PRICE PER METER PART NO. PRICE 50FT COIL PART NO. PRICE<br />
Type 316 SS<br />
1/8” (3.18mm) 0.085" (2.16mm) 30105 30107 30109<br />
1/4" (6.35mm) 0.210" (5.33mm) 30307 30308 30309<br />
Type 304 SS<br />
1/8" (3.18mm) 0.085" (2.16mm) 30102 30104 30106<br />
1/4" (6.35mm) 0.210" (5.33mm) 30302 30304 30306<br />
*Minimum tubing order is 3 ft<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Tubing<br />
Stainless Steel Tubing<br />
Standard Grade Stainless Steel Tubing<br />
• Economical<br />
• Same as HI-EFF ® without washing<br />
5098<br />
Alltech Can Provide an Acetone<br />
Washing Service<br />
Remove residual contaminants from<br />
any tubing surface between 1/8" and<br />
3/8" o.d. and up to 50' coils. Order Part<br />
Number C-3001.<br />
PER FT*<br />
PART NO.<br />
STANDARD STAINLESS STEEL TUBING<br />
PER METER<br />
50FT COIL<br />
200FT COIL<br />
O.D.<br />
I.D.<br />
PRICE PART NO. PRICE PART NO. PRICE PART NO. PRICE<br />
Type 316 SS<br />
1/32" (0.79mm) 0.007" (0.18mm) 8195 81953 81951 — —<br />
0.004" (0.10mm) 30211 30213 30212 — —<br />
0.007" (0.18mm) 30141 301430 30142 — —<br />
0.010" (0.25mm) 30051 300530 3005 30052<br />
1/16" (1.59mm) 0.020" (0.51mm) 3002100 300230 3002 300220<br />
0.030" (0.76mm) 300010 300030 3000 300020<br />
0.040" (1.02mm) 30031 30033 3003 — —<br />
0.050" (1.27mm) 30041 30043 3004 — —<br />
Type 304 SS<br />
1/8" (3.18mm) 0.085" (2.16mm) 30101 30103 3010 30108<br />
3/16" (4.76mm) 0.147" (3.73mm) 30201 30203 3020 — —<br />
1/4" (6.35mm) 0.210" (5.33mm) 30301 30303 3030 — —<br />
3/8" (9.53mm) 0.305" (7.75mm) 30321 30323 3032 † — —<br />
*Minimum tubing order is 3ft<br />
†<br />
40 ft coil<br />
Straight Stainless Steel Tubing<br />
• Type 304 SS<br />
• 6ft or 10ft lengths<br />
5097<br />
PTFE-Coated Stainless Steel Tubing<br />
• Sturdy SS tube with 0.001" thick PTFE<br />
coating<br />
• Must be preconditioned at 250°C for<br />
three hours<br />
5103<br />
STRAIGHT STAINLESS STEEL TUBING<br />
O.D. I.D. LENGTH* QTY PART NO. PRICE<br />
1/8" (3.18mm) 0.085" (2.16mm) 6 ft 10 30106ST<br />
1/8" (3.18mm) 0.085" (2.16mm) 10 ft 10 301010ST<br />
1/4" (6.35mm) 0.210" (5.33mm) 6 ft 10 30306ST<br />
1/4" (6.35mm) 0.210" (5.33mm) 10 ft 10 303010ST<br />
*10ft lengths must ship via motor freight<br />
PTFE-COATED STAINLESS STEEL TUBING<br />
O.D. I.D. LENGTH PART NO. PRICE<br />
1/8" (3.18mm) 0.085"(2.16mm) per ft* 31421<br />
1/8" (3.18mm) 0.085"(2.16mm) 50 ft 3142<br />
1/4" (6.35mm) 0.210"(5.33mm) per ft* 31441<br />
1/4" (6.35mm) 0.210"(5.33mm) 50 ft 3144<br />
*Minimum tubing order is 3 ft<br />
Glass-Lined Stainless Steel<br />
Tubing (GLT)<br />
• Flow lines for corrosives<br />
• <strong>GC</strong>/MS interfaces<br />
• Capillary column connections<br />
5101<br />
PTFE-Lined Stainless Steel Tubing<br />
• Ideal for use with reactive chemicals<br />
and for trace quantities of water<br />
• Order PTFE ferrules to grip SS and PTFE<br />
portions of tubing below<br />
5102<br />
GLASS-LINED STAINLESS STEEL TUBING<br />
O.D. I.D. LENGTH PART NO. PRICE<br />
1/16" (1.59mm) 0.3mm 180cm 3137<br />
1/16" (1.59mm) 0.5mm 180cm 3164<br />
1/16" (1.59mm) 0.7mm 180cm 3139<br />
1/8" (3.18mm) 0.75mm 180cm 3166<br />
1/8" (3.18mm) 1.0mm 180cm 3168<br />
1/8" (3.18mm) 1.5mm 180cm 3170<br />
1/8" (3.18mm) 1.8mm 180cm 3141<br />
1/4" (6.35mm) 4.0mm 180cm 3149<br />
© Copyright 2004 Alltech Associates, Inc.<br />
PTFE-LINED STAINLESS STEEL TUBING<br />
O.D. I.D. LENGTH QTY PART NO. PRICE<br />
1/8" (3.18mm) 0.070" (1.78mm) 6 ft 1 3152<br />
1/8" (3.18mm) 0.070" (1.78mm) 10 ft 1 3154<br />
1/4" (6.35mm) 0.180" (4.57mm) 6 ft 1 3156<br />
1/4" (6.35mm) 0.180" (4.57mm) 50 ft 1 3158<br />
PTFE FERRULES<br />
O.D. QTY PART NO. PRICE<br />
1/8" 10 6552<br />
1/4" 10 6554<br />
Contact your Alltech office or distributor for current or local prices.<br />
423
Tubing<br />
A C C E S S O R I E S<br />
Metal Tubing<br />
Aluminum Tubing<br />
• Economical choice for <strong>GC</strong> gas lines<br />
5106<br />
Polymeric Tubing<br />
• Maximum<br />
Inertness<br />
PFA FEP PTFE POLYPROPYLENE<br />
ALUMINUM TUBING<br />
O.D. I.D. LENGTH PART NO. PRICE<br />
1/8" (3.18mm) 0.065" (1.65mm) 50ft 3090<br />
3/16" (4.76mm) 0.128" (3.25mm) 50ft 3100<br />
1/4" (6.35mm) 0.190" (4.83mm) 50ft 3110<br />
3/8" (9.53mm) 0.315" (8.00mm) 50ft 3120<br />
Copper Tubing<br />
• Economical choice for <strong>GC</strong> gas lines<br />
COPPER TUBING<br />
O.D. I.D. LENGTH PART NO. PRICE<br />
1/8" (3.18mm) 0.065" (1.65mm) 50ft 3040<br />
3/16" (4.76mm) 0.128" (3.25mm) 50ft 30509<br />
1/4" (6.35mm) 0.190" (4.83mm) 50ft 30609<br />
3/8" (9.53mm) 0.315" (8.00mm) 50ft 30709<br />
5100<br />
PFA (Perfluoroalkoxy) Tubing<br />
PFA (PERFLUOROALKOXY) TUBING<br />
O.D. I.D. LENGTH PART NO. PRICE<br />
1/16" (1.59mm) 0.030" (0.76mm) 25 ft 45734<br />
1/8" (3.18mm) 0.062" (1.57mm) 25 ft 45735<br />
1/4" (6.35mm) 0.156" (3.96mm) 25 ft 45736<br />
FEP (Fluorinated Ethylene Polypropylene)<br />
Tubing<br />
FEP (FLUORINATED ETHYLENE POLYPROPYLENE) TUBING<br />
O.D. I.D. LENGTH PART NO. PRICE<br />
1/16" (1.59mm) 0.030" (0.76mm) 25 ft 45739<br />
1/8" (3.18mm) 0.062" (1.57mm) 25 ft 45740<br />
1/4" (6.35mm) 0.156" (3.96mm) 25 ft 45741<br />
5104a<br />
424<br />
Nickel Tubing<br />
• Pure Nickel 200, more inert than<br />
stainless steel<br />
• Acid washed and rinsed for additional<br />
inertness<br />
NICKEL TUBING<br />
O.D. I.D. PART NO. PRICE<br />
Per Foot*<br />
1/16" (1.59mm) 0.010" (0.25mm) 30831<br />
1/16" (1.59mm) 0.020" (0.51mm) 31311<br />
1/16" (1.59mm) 0.040" (1.02mm) 30851<br />
1/8" (3.18mm) 0.083" (2.11mm) 30801<br />
1/4" (6.35mm) 0.210" (5.33mm) 30811<br />
Per Meter<br />
1/16" (1.59mm) 0.010" (0.25mm) 30833<br />
1/16" (1.59mm) 0.020" (0.51mm) 31313<br />
1/16" (1.59mm) 0.040" (1.02mm) 30853<br />
1/8" (3.18mm) 0.083" (2.11mm) 30803<br />
1/4" (6.35mm) 0.210" (5.33mm) 30813<br />
50 Foot Coil<br />
1/16" (1.59mm) 0.010" (0.25mm) 3083<br />
1/16" (1.59mm) 0.020" (0.51mm) 3131<br />
1/16" (1.59mm) 0.040" (1.02mm) 3085<br />
1/8" (3.18mm) 0.083" (2.11mm) 3080<br />
1/4" (6.35mm) 0.210" (5.33mm) 3081<br />
200 Foot Coil<br />
1/16" (1.59mm) 0.010" (0.25mm) 30832<br />
1/16" (1.59mm) 0.020" (0.51mm) 31312<br />
*Minimum tubing order is 3ft<br />
© Copyright 2004 Alltech Associates, Inc.<br />
PTFE (Tetrafluoroethylene) Tubing<br />
TFE (TETRAFLUOROETHYLENE) TUBING<br />
O.D. I.D. LENGTH PART NO. PRICE<br />
1/16" (1.59mm) 0.038" (0.96mm) per ft † 31321<br />
1/16" (1.59mm) 0.038" (0.96mm) per meter † 31323<br />
1/16" (1.59mm) 0.038" (0.96mm) 50 ft 3132<br />
1/8" (3.18mm) 0.098" (2.49mm) per ft* 31341<br />
1/8" (3.18mm) 0.098" (2.49mm) per meter † 31343<br />
1/8" (3.18mm) 0.098" (2.49mm) 50 ft 3134<br />
1/4" (6.35mm) 0.125" (3.17mm) per ft* 31361<br />
1/4" (6.35mm) 0.125" (3.17mm) per meter † 31363<br />
1/4" (6.35mm) 0.125" (3.17mm) 50 ft 3136<br />
*6ft minimum †2m minimum<br />
Polypropylene/Polyethylene Tubing<br />
POLYPROPYLENE/POLYETHYLENE TUBING<br />
O.D. I.D. TYPE LENGTH PART NO. PRICE<br />
1/8" (3.18mm) 0.080" (2.03mm) PP 50 ft 3203<br />
1/8" (3.18mm) 0.080" (2.03mm) PP 100 ft 3201<br />
1/4" (6.35mm) 0.125" (3.17mm) PE 50 ft 3207<br />
1/4" (6.35mm) 0.125" (3.17mm) PE 100 ft 3205<br />
Need Fittings?<br />
See pages 417-421 for a complete<br />
selection of <strong>GC</strong> fittings.<br />
For PEEK and other HPLC tubing, refer to pages<br />
230-235. For fused silica tubing, see page 386.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Tubing<br />
Tubing Cutters<br />
Plastic Tubing Shear<br />
• Cuts all types of plastic tubing<br />
• Stainless steel blade makes clean, square cuts<br />
• Compact - only 3" Long<br />
PLASTIC TUBING SHEAR<br />
DESCRIPTION QTY PART NO. PRICE<br />
Plastic Tubing Shear ea 3206<br />
Replacement Blade ea 3214<br />
5376<br />
Rotary Tubing Cutter<br />
• Cuts 1/32" to 1/8" o.d. tubing<br />
• Leaves tubing i.d. open<br />
• Cuts metal and glass-lined tubing<br />
• No deburring or ream ing necessary<br />
ROTARY TUBING CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Rotary Tubing Cutter ea 3165<br />
Replacement Cutting Wheels 3 3167<br />
5110<br />
Clean-Cut Tubing Cutter<br />
• Cuts PTFE, Tefzel ® , Polyolefin, PEEK<br />
• Make clean, square cuts without<br />
deforming i.d.s<br />
CLEAN-CUT TUBING CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Clean-Cut Tubing Cutter ea 35902<br />
Replacement Blade ea 35903<br />
Plier-Type Tubing Cutter<br />
• Cuts 1/16" o.d. tubing<br />
• Ideal for cutting tubing in tight places<br />
PLIER-TYPE TUBING CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Plier-Type Tubing Cutter ea 3169<br />
Cutting Kit For 1/16" Tubing<br />
• Knife file and rig for scoring<br />
the tubing to a preset depth<br />
• Scoring provides a clean and<br />
even break<br />
• Stops are provided for 0.010", 0.020" and<br />
0.030" i.d. tubing<br />
CUTTING KIT FOR 1/16" TUBING<br />
DESCRIPTION QTY PART NO. PRICE<br />
Cutting Kit ea 7180<br />
Replacement Knife File ea 7181<br />
5377<br />
3306<br />
5111<br />
Imp Tubing Cutter<br />
• Cuts SS, copper, nickel, & aluminum tubing<br />
• Ideal for tight spaces<br />
• Requires only 1-3/4" swing radius<br />
IMP TUBING CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Imp Tubing Cutter ea 3208<br />
Replacement Cutting Wheels 5 320210<br />
Imperial Tubing Cutter<br />
• Cuts 1/8" to 1-1/8" o.d. tubing<br />
• Makes clean, right-angle cuts with no<br />
burring<br />
• Includes spare cutting wheel<br />
IMPERIAL TUBING CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Imperial Tubing Cutter ea 3210<br />
Replacement Cutting Wheels 2 3212<br />
Heavy-Duty Cutting Wheels 3 13984<br />
Heavy-Duty Tubing Cutter<br />
• Cuts stainless steel, copper,<br />
nickel, and aluminum tubing<br />
• Cuts 1/8" to 1-1/8" o.d.<br />
tubing<br />
HEAVY-DUTY TUBING CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Heavy-Duty Tubing Cutter ea 13995<br />
Replacement Cutting Wheels 3 13981<br />
5113<br />
5114<br />
5112<br />
Glass Tubing Cutter<br />
Glass Knife Cutter<br />
• Makes glass cutting a snap<br />
• More accurate than a file<br />
3314<br />
• Cuts capillary fused silica<br />
and glass tubing of all sizes.<br />
• Includes a double edged<br />
tungsten carbide blade.<br />
0033<br />
GLASS TUBING CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Glass Tubing Cutter ea 3150<br />
Replacement Cutting Wheels 3 3150CW<br />
© Copyright 2004 Alltech Associates, Inc.<br />
GLASS KNIFE CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Glass Knife Cutter ea 5600<br />
Replacement Blade ea 5601<br />
Contact your Alltech office or distributor for current or local prices.<br />
425
Tubing<br />
A C C E S S O R I E S<br />
Tubing Cutters & <strong>Accessories</strong><br />
426<br />
Electric Tubing Cutter<br />
Assure zero dead volume connections<br />
• Clamp vise securely holds tubing in<br />
place<br />
• Cut 1/16", 1/8" and 1/4" o.d.<br />
tubings with i.d.’s as small as<br />
0.008"<br />
• Requires no lubricant or cutting<br />
fluid<br />
This electric tubing cutter assures square and burrfree<br />
cuts for maximum chromatographic performance.<br />
Use the included dressing tool for 1/16" o.d. tubing<br />
to finish the inside and outside diameters of tubing<br />
ends. Dressing tool for 1/8" and 1/4" o.d. tubing and<br />
replacement cutting wheels can be ordered separately<br />
below. Tubing cutter is voltage selectable for 110-120/<br />
220-240 VAC, 50/60 Hz.<br />
Fused Silica Cutter<br />
• Cleanly cut fused silica tubing<br />
• Small enough to keep handy in<br />
your pocket<br />
Tubing Reamers<br />
• Smooth and debur metal tubing ends<br />
• 1/16" reamer set includes inner & outer reamers<br />
• Inner reamers handles most tubing i.d.s<br />
Inner Reamer<br />
Outer Reamer<br />
ELECTRIC TUBING CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Electric Tubing Cutter ea 10-0200<br />
Replacement Part and <strong>Accessories</strong><br />
Dressing tool for 1/8" and 1/4" o.d. Tubing ea 13984<br />
Replacement cutting wheels 3 10-0124<br />
Repl. dressing tool for 1/16" o.d. tubing ea 10-0116<br />
FUSED SILICA CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Fused Silica Cutter 5 3194<br />
TUBING REAMERS<br />
DESCRIPTION QTY PART NO. PRICE<br />
1/16" Reamer Set ea 13974<br />
1/8" Outer Reamer ea 32199<br />
1/4" Outer Remer ea 32219<br />
Inner Reamer for 1/8"-3/8" o.d. ea 32159<br />
© Copyright 2004 Alltech Associates, Inc.<br />
5117<br />
5118<br />
6281<br />
4502<br />
SGT Shortix Capillary Column<br />
Cutter<br />
• Makes perfect fused silica cuts<br />
• Rotating diamond blade precisely<br />
scores capillary columns<br />
• Edges are clean & straight, column<br />
walls are undamaged<br />
• Cuts 100-500µm i.d. capillaries<br />
Capillary Scribers<br />
• Make clean scratches and breaks of fused silica<br />
capillary tubing<br />
• Tungsten carbide tipped marks steel, stainless steel,<br />
and ceramics<br />
• Diamond-tipped marks any surface - even glass<br />
6258 6259<br />
Diamond-Tipped Scriber<br />
Compact Tube Bender<br />
CAPILLARY COLUMN CUTTER<br />
DESCRIPTION QTY PART NO. PRICE<br />
Shortix Column Cutter ea 5190<br />
Replacement Blade ea 5192<br />
CAPILLARY SCRIBERS<br />
DESCRIPTION QTY PART NO. PRICE<br />
Tungsten Carbide Scriber ea 3155<br />
Diamond-tipped Scriber ea 3159<br />
• Bends 1/8", 3/16", 1/4", 3-, 4-,<br />
5-, and 6mm tubing<br />
• Easily bends copper,<br />
aluminum, and thin walled<br />
steel tubing<br />
COMPACT TUBE BENDER<br />
Heavy-Duty Tube Benders<br />
• Bend heavy-walled tubing<br />
with ease<br />
Tungsten Carbide Scriber<br />
DESCRIPTION QTY PART NO. PRICE<br />
Compact Tube Bender ea 3232<br />
HEAVY-DUTY TUBE BENDER<br />
DESCRIPTION QTY PART NO. PRICE<br />
For 1/8" Tubing ea 3220<br />
For 1/4" Tubing ea 3224<br />
Contact your Alltech office or distributor for current or local prices.<br />
5116<br />
5115<br />
4394
A C C E S S O R I E S<br />
Injection Liners<br />
Deactivated Injection Liners<br />
DEACTIVATED INJECTION LINERS<br />
DESCRIPTION AND LENGTH X O.D.<br />
DIAGRAM<br />
Injection Liners for Agilent/Hewlett-Packard Instruments*<br />
Cup Splitter<br />
78.5 x 6.3mm<br />
Split/Splitless with Deactivated Quartz<br />
Wool, 78.5 x 6.3mm o.d., 4mm i.d.<br />
Splitless,<br />
78.5 x 6.3mm o.d., 4mm i.d.<br />
Quartz Splitless,<br />
78.5 x 6.0mm, 2mm i.d.<br />
Recessed Gooseneck with Deactivated<br />
Quartz Wool, 78.5 x 6.3mm, 4mm i.d.<br />
Recessed Gooseneck,<br />
78.5 x 6.3mm, 2mm i.d.<br />
Direct,<br />
78.5 x 6.3mm, 1.5mm i.d.<br />
Injection Liners for Varian Instruments<br />
Splitter with Deactivated Quartz Wool,<br />
1075/1077, 72 x 6.3mm, 4mm i.d.<br />
Frit Splitter, 1075/1077,<br />
72 x 6.3mm, 4mm i.d.<br />
Baffle Splitter, 1075/1077,<br />
72 x 6.3mm, 4mm i.d.<br />
Splitless 1075/1077, 74 x 6.3mm, 2mm<br />
i.d.<br />
0.8mm SPI 1093/1094,<br />
54 x 4.6mm<br />
0.5mm SPI 1093/1094,<br />
54 x 4.6mm<br />
SPI with Buffer 1093/1094,<br />
54 x 4.6mm<br />
Injection Liners for Perkin-Elmer Instruments<br />
Split/Splitless 8500, 8600,<br />
100 x 5.0mm, 3mm i.d.<br />
Splitless 8500, 8600,<br />
100 x 5.0mm, 2mm i.d.<br />
PTV Liner 8500, 8600,<br />
88 x 2.0mm, 1mm i.d.<br />
Split/Splitless Autosystem,<br />
92 x 5.8mm, 4mm i.d.<br />
Split/Splitless Autosystem,<br />
92 x 5.8mm, 2mm i.d.<br />
Injection Liners for Shimadzu Instruments<br />
Split 17A with Deactivated Quartz<br />
Wool, 95.5 x 5.0mm, 3mm i.d.<br />
Splitless 17A,<br />
95.5 x 5.0mm, 3mm i.d.<br />
Gooseneck/Splitless,<br />
95.5 x 5.0mm, 3mm i.d.<br />
Split 9A, 15A, 16A,<br />
127.5 x 5.0mm, 3mm i.d.<br />
Splitless 9A, 15A, 16A,<br />
127.5 x 5.0mm, 3mm i.d.<br />
Injection Liners for Finnigan Instruments<br />
Splitless 5100 Series,<br />
85 x 6.3mm, 2mm i.d.<br />
Splitless 4100 Series,<br />
112 x 4.5mm, 2mm i.d.<br />
*Also compatible with Varian Model CP-1177 Split/Splitless Injector Port<br />
© Copyright 2004 Alltech Associates, Inc.<br />
EACH<br />
PART NO.<br />
PRICE<br />
5/PK<br />
PART NO.<br />
PRICE<br />
25/PK<br />
PART NO.<br />
4825 4827 4829<br />
4906 4924 4928<br />
4929 4934 4936<br />
4962 4963 4964<br />
4959 4960 4961<br />
4958 4938 4957<br />
4967 4968 4969<br />
4970 4971 4972<br />
4973 4974 4975<br />
4977 4978 4979<br />
4980 4981 4982<br />
4983 4984 4985<br />
4986 4987 4988<br />
4989 4990 4991<br />
4790 4792 4794<br />
4992 4993 4994<br />
4995 4996 4997<br />
4796 4798 4800<br />
4810 4812 4814<br />
4748 4750 4752<br />
4754 4756 4758<br />
4760 4762 4764<br />
4766 4768 4770<br />
4772 4774 4776<br />
4856 4857 4858<br />
4859 4860 4862<br />
PRICE<br />
Contact your Alltech office or distributor for current or local prices.<br />
427
Injection Liners<br />
A C C E S S O R I E S<br />
DEACTIVATED INJECTION LINERS (CONT’D)<br />
DESCRIPTION AND LENGTH X O.D.<br />
Injection Liners for Carlo Erba-Fisons Instruments<br />
Split/Splitless 6000 Series with Deactivated<br />
Quartz Wool, 79.5 x 5.0mm, 3mm i.d.<br />
Splitless 6000 Series, 79.5 x 5.0mm, 4mm<br />
i.d.<br />
Splitless 6000 Series, 79.5 x 5.0mm, 2mm<br />
i.d.<br />
DIAGRAM<br />
EACH<br />
PART NO.<br />
PRICE<br />
5/PK<br />
PART NO.<br />
PRICE<br />
25/PK<br />
PART NO.<br />
4742 4744 4746<br />
4853 4854 4855<br />
4998 4851 4852<br />
Split 8000 Series, 105 x 8.0mm, 3mm i.d. 4784 4786 4788<br />
PRICE<br />
Deactivated SGE FocusLiners<br />
DESCRIPTION AND LENGTH X O.D.<br />
DEACTIVATED SGE FOCUSLINERS<br />
DIAGRAM<br />
5/PK<br />
PART NO.<br />
PRICE<br />
25/PK<br />
PART NO.<br />
for Agilent/Hewlett Packard Instruments*<br />
FocusLiner, 78.5 x 6.3 x 4mm i.d. 85474 85480<br />
PRICE<br />
Tapered FocusLiner, 78.5 x 6.3 x 4mm i.d. 85481 85574<br />
FAST FocusLiner, 78.5 x 6.3 x 2.3mm i.d. 85605 85606<br />
Tapered FAST FocusLiner,<br />
78.5 x 6.3 x 2.3mm i.d.<br />
85607 — —<br />
for Varian Injector Models 1075/1077<br />
FocusLiner, 72 x 6.3 x 4mm i.d. 85477 — —<br />
Tapered FocusLiner, 74 x 6.3 x 4mm i.d. 85484 — —<br />
FocusLiner w/Top Restriction,<br />
85633 — —<br />
72 x 6.3 x 4mm i.d.<br />
FAST FocusLiner, 72 x 6.3 x 2.3mm i.d. 85634 — —<br />
for Varian Injector Models 1078/1079<br />
FocusLiner, 54 x 5 x 3.4mm i.d. 85437 — —<br />
Tapered FocusLiner, 54 x 5 x 3.4mm i.d. 85635 — —<br />
for Shimadzu 17A<br />
FocusLiner, 95 x 5 x 3.4mm i.d. 85476 — —<br />
Tapered FocusLiner, 95 x 5 x 3.4mm i.d. 85483 — —<br />
for Shimadzu 14/15A/16<br />
FocusLiner, 99 x 5 x 3.4mm i.d. 85608 — —<br />
Tapered FocusLiner, 99 x 5 x 3.4mm i.d. 85630 — —<br />
for Perkin Elmer Autosystem<br />
FocusLiner, 92 x 6.2 x 4mm i.d. 85478 — —<br />
Tapered FocusLiner, 92 x 6.2 x 4mm i.d. 85482 — —<br />
for ThermoQuest Model 8000/TRACE<br />
FocusLiner, 105 x 8 x 5mm i.d. 85631 — —<br />
Tapered FocusLiner, 105 x 8 x 5mm i.d. 85632 — —<br />
* Also compatible with Varian model CP-1177 Split/Splitless injection port.<br />
428<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.
A C C E S S O R I E S<br />
Injector <strong>Accessories</strong><br />
<strong>GC</strong> O-rings<br />
• Thermally Stable<br />
• No Bleed<br />
• Suitable for <strong>GC</strong>/MS<br />
Graphite O-rings may replace the Viton ® or silicone<br />
O-rings normally used to seal the Agilent 5890 Split and<br />
Splitless injection liners. Splitless liners have an internal<br />
diameter of 6.5mm and split liners have an internal<br />
diameter of 6.35mm.<br />
Specifications<br />
PROPERTY GRAPHITE SILICONE PTFE VITON ®<br />
Max. Temp. 450°C 230°C 230°C 200°C<br />
Chem. Rest. Good Good Superb Superb<br />
Durability Superb Moderate Superb Good<br />
Bleed None Medium Low Low<br />
Color Black Red White Black<br />
O-RINGS<br />
SIZE QTY. PART NO. PRICE<br />
Graphite <strong>GC</strong> O-rings (450°C Limit)<br />
1/4" (6.5mm i.d.) 10 7160<br />
1/4" (6.35mm i.d.) 10 7176<br />
Silicone O-rings (230°C Limit)<br />
1/8" 100 7020<br />
3/16" 100 7021<br />
1/4" 100 7022<br />
PTFE O-rings (230°C Limit)<br />
1/8" 100 7023<br />
3/16" 100 7024<br />
1/4" 100 7025<br />
Viton ® O-rings (200°C Limit)<br />
1/8" 100 7017<br />
3/16" 100 7018<br />
1/4" 100 7019<br />
Graphite Washer (450°C Limit)<br />
1/4" i.d. x 7/16" o.d., 1/32" Thick 10 7165<br />
Don't Forget Septa!<br />
See pages 431-433 for a complete selection of septa.<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Injector Supplies for<br />
HP/Agilent 5890/6890 <strong>GC</strong>s<br />
Inlet Seals for HP/Agilent 5890/6890 <strong>GC</strong>s are<br />
available either stainless steel (similar to HP/<br />
Agilent part no. 18740-20880)<br />
or gold plated (similar to<br />
HP/Agilent part no. 18740-<br />
20885). Washers are included<br />
with the inlet seals.<br />
The Reducing Nut for HP/Agilent 5890/6890 <strong>GC</strong>s is<br />
made from stainless steel and is similar to HP/Agilent<br />
part no. 18740-20800.<br />
INJECTOR SUPPLIES FOR HP/AGILENT 5890/6890 <strong>GC</strong>S<br />
DESCRIPTION QTY PART NO. PRICE<br />
Inlet Seal, stainless steel (0.8mm hole)<br />
Inlet Seal, gold plated (0.8mm hole)<br />
Reducing Nut Replacement for HP 5890/<br />
6890<br />
1 15146<br />
10 151461<br />
25 151462<br />
1 15147<br />
10 151471<br />
25 151472<br />
1 15145<br />
Washers, stainless steel (0.375"o.d.) 10 15148<br />
MSD Source Nut, brass 1 15104<br />
<strong>Accessories</strong> for<br />
HP/Agilent &<br />
Varian Capillary Systems<br />
HP/Agilent nuts are available in both standard and<br />
“deep well” versions, with either standard wrench flats<br />
or knurled for easy wrench-free fingertight connections.<br />
The deep well nuts have 2.4mm deep ferrule wells<br />
to accommodate standard capillary ferrules, and the<br />
standard type has a 1.65mm deep ferrule well for HPtype<br />
capillary ferrules.<br />
ACCESSORIES FOR HP/AGILENT AND VARIAN<br />
DESCRIPTION QTY PART NO. PRICE<br />
Capillary Nuts<br />
Capillary Nuts for Varian 2 154740<br />
Capillary Nuts for HP/Agilent 2 154780<br />
Wrench-Free Capillary Nuts for HP/Agilent 2 154785<br />
Deep Well Capillary Nuts for HP/Agilent 2 154781<br />
Wrench-Free Deep Well for HP/Agilent 2 154782<br />
Graphite Ferrules for HP/Agilent<br />
Graphite Ferrules, 0.5mm Hole* 10 1547901<br />
Graphite Ferrules, 1.0mm Hole** 10 1548001<br />
Wrench<br />
5/16" x 1/4" Open-End Wrench ea 1998<br />
* for 0.25 and 0.32mm i.d. Capillary Column.<br />
** for 0.45 and 0.53mm i.d. Capillary Column.<br />
Contact your Alltech office or distributor for current or local prices.<br />
6650<br />
6651<br />
429
Kits<br />
A C C E S S O R I E S<br />
430<br />
Alltech<br />
Maintenance<br />
Kit for<br />
HP/Agilent <strong>GC</strong>’s<br />
• Easily maintain the injector and FID<br />
• For use with HP/Agilent 5890 and 6890 <strong>GC</strong>’s<br />
Your results rely on the performance of your <strong>GC</strong>. The<br />
Maintenance Kit for HP/Agilent <strong>GC</strong>’s contains all the<br />
supplies you need to perform routine maintenance and<br />
trouble-shooting on your injector and FID.<br />
Kit Includes:<br />
For Column Installation<br />
• 2 - HP style capillary nuts<br />
• 10 - 0.5mm HP style graphite ferrules<br />
• 10 - 1.0mm HP style graphite ferrules<br />
For Injector Maintenance & Troubleshooting<br />
• 5 - split/splitless liner with deactivated quartz wool,<br />
4mm i.d.<br />
• 5 - splitless liner, 4mm i.d.<br />
• 100 - 1/4" Viton o-rings<br />
• 10 -1/4" graphite ferrules<br />
• 25 - 9.5mm ThermoRed septa<br />
• 2 - 0.8mm stainless steel inlet seals<br />
For Detector Maintenance & Troubleshooting<br />
• 40 - 1' lengths redi cut wire (10 each 0.003", 0.005",<br />
0.010", & 0.020" o.d.)<br />
• 4 - stainless steel tube brushes<br />
ALLTECH’S MAINTENANCE KIT FOR HP/AGILENT <strong>GC</strong>’S<br />
DESCRIPTION PART NO. PRICE<br />
Alltech Answer Maintenance Kit 20814<br />
Have a Question about Your Order?<br />
For other Alltech Kits, including the EPA Method 552.1<br />
for Haloacetic Acids in Water Kit, and the USP Method<br />
467 Kits, request data sheet 20830.<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact Alltech Customer Service:<br />
Online Ordering 24 hours a day:<br />
www.alltechWEB.com<br />
Email: alltech@alltechemail.com<br />
5828<br />
Alltech <strong>GC</strong><br />
Start-Up Kit<br />
• Convenient<br />
• Suitable for use with any capillary <strong>GC</strong><br />
Kit contains the necessary tools to set up and operate<br />
your <strong>GC</strong>. Alltech’s <strong>GC</strong> Start Up Kit includes all the<br />
supplies you need to install columns, set gas flows, set<br />
linear velocity, and perform routine maintenance on your<br />
<strong>GC</strong>.<br />
Kit includes:<br />
For General Maintenance<br />
• 4 - open-end wrenches (2 each, 7/16" x 1/2" & 9/16"<br />
x 5/8")<br />
• 1 - 2-way reversible screwdriver<br />
• 25 - 9.5mm and 11mm ThermoRed septa<br />
• 1 - septa puller<br />
• 4 - stainless steel tube brushes<br />
• 40 - 1' lengths redi-cut wire<br />
(10 of each diameter - 0.003", 0.005", 0.010" &<br />
0.020" o.d.)<br />
• 8oz. - leak-check soapfilm solution<br />
For Column Installation<br />
• 2 - open-end wrenches (1/4" x 5/16")<br />
• 1 - scriber for cutting fused silica tubing<br />
• 1 pair - PTFE coated forceps<br />
• 1 - Pick (for removing ferrules from fittings)<br />
• 1 - laminated ruler<br />
• 10' length - high temperature string<br />
• 1 - 20X magnifier (for checking ends of tubing)<br />
• 2' length - pipecleaner (for cleaning liners)<br />
• 10 - 1/16" to 0.4mm, 0.5mm, and 0.8mm graphite<br />
ferrules<br />
For Setting Gas Flows<br />
• 1 - 100cc soapfilm flow meter<br />
• 10' length - 5/16" Tygon tubing<br />
• 1 - stopwatch<br />
For Setting Linear Velocity<br />
• 1- Hamilton 1701 and 701 Gastight Syringe with<br />
Removable needle and 3 replacement needles<br />
• 1 - 14L Scotty II 99.99% methane standard<br />
• 1 - Scotty II syringe adapter<br />
ALLTECH’S <strong>GC</strong> START UP KIT<br />
DESCRIPTION PART NO. PRICE<br />
Alltech Answer <strong>GC</strong> Start Up Kit 20810<br />
Contact your Alltech office or distributor for current or local prices.<br />
3967
A C C E S S O R I E S<br />
Septa<br />
How to select a septum for your<br />
application<br />
Specifications<br />
ACTUAL SIZE DRAWING MEASUREMENT CHROMATOGRAPH<br />
4610<br />
With so many septa to choose from, choosing a<br />
septum for your application can be a confusing task.<br />
There are a number of criteria you need to consider<br />
when selecting a septum.<br />
1. Make and Model of Gas Chromatograph –<br />
This will determine what size of septum you need.<br />
Alltech carries a full range of septum sizes to fit<br />
most gas chromatographs.<br />
2. Performance – A high performance, low bleed<br />
septum is desirable so that septa bleed does not<br />
interfere with the chromatography of your sample.<br />
Keep in mind that all septa bleed to some extent.<br />
The amount of bleed visible to the detector is<br />
affected by several factors which include:<br />
- The composition and pretreatment of the<br />
septum material.<br />
- The sensitivity setting of the detector<br />
amplifier.<br />
- The type of detector.<br />
- The injection port setting.<br />
- Isothermal or temperature programming.<br />
- The type of injection (direct, splitless,<br />
split, etc.)<br />
Choose a high performance septum such as<br />
Alltech’s ThermoRed or XLB septa to minimize septa<br />
bleed.<br />
3. Injection Port Temperature - The temperature<br />
of the septum never reaches the injection port<br />
temperature setting. The center of the injector<br />
heated zone, where the sample is deposited,<br />
is regulated to correspond to the injector port<br />
setting. Be sure to select a septum with a maximum<br />
temperature that exceeds your injection port<br />
temperature.<br />
4. Penetration/Resealing Qualities - Ideally,<br />
you want a septum that is soft and easily<br />
penetrated by a syringe needle and has excellent<br />
resealing properties. This will prevent you from<br />
bending syringe needles and coring of the septum<br />
to give you longer septum life. Excellent resealing<br />
properties will prevent leaks that might adversely<br />
affect your chromatography or damage your<br />
analytical column.<br />
Septa Selection Guide<br />
PRODUCT MAX. TEMP. COLOR DUROMETER* LOW BLEED<br />
Thermo Red 300°C Red 50-55 Excellent<br />
XLB 350°C Green 50-55 Excellent<br />
HT-X High<br />
Performance<br />
350°C Blue 50-60 Excellent<br />
General Purpose<br />
White<br />
250°C White 40-45 Very Good<br />
Standard Blue 300°C Blue 55-60 Very Good<br />
General Purpose<br />
Blue<br />
250°C Blue 40-45 Good<br />
Cylindrical Half<br />
Hole<br />
250°C Blue 50-55 Very Good<br />
Cylindrical 3-layer 200°C Red 50-55 Excellent<br />
Three Layer 300°C<br />
Red/<br />
White<br />
50-55 Good<br />
Four Layer 225°C<br />
Microsep<br />
PTFE-lined<br />
Microsep Low<br />
bleed PTFE-lined<br />
1/4"(6mm)<br />
3/8"<br />
(9.5mm)<br />
7/16"<br />
(11mm)<br />
1/2"<br />
(12.5mm)<br />
21/32"<br />
(17mm)<br />
* Use cylindrical plug septa, see page 432.<br />
250°C<br />
250°C<br />
Shimadzu*, SRI*<br />
Antek, Finnigan 9100, 9600,<br />
Gow-Mac, Agilent 5700, 5880<br />
& 5900, IBM, Packard 427-433,<br />
Pye-Unicam (early models),<br />
Varian (except capillary inj.),<br />
Tracor 550, 560.<br />
Carle, Agilent 5890,6850,6890.<br />
P-E Sigma, 900, 990, 3920,<br />
8300, 8400, 8500 Autosys,<br />
Varian (capillary injector), SPI,<br />
Varian 1078/1079<br />
Fisons/Carlo Erba, Finnigan<br />
9500, HP/Agilent 5750 and<br />
earlier models, Packard 409-<br />
421, Tracor 220, 222, 540.<br />
Fisons/Carlo Erba 8000 Series,<br />
CE TRACE <strong>GC</strong><br />
Red/<br />
White<br />
Off<br />
White<br />
Yellow/<br />
Off<br />
White<br />
50-55 Good<br />
25-35 Good<br />
25-35 Very Good<br />
* Durometer - Harness of the silicone material. The lower the number, the<br />
softer the material.<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
431
Septa<br />
A C C E S S O R I E S<br />
Septa<br />
General Purpose Blue Septa<br />
• Maximum temperature of 250°C<br />
(300°C for short periods)<br />
• Lifetime of up to 150 injections<br />
• Suitable for most <strong>GC</strong> analysis<br />
4603<br />
XLB Septa<br />
• Maximum temperature to 350°C<br />
• Extremely low bleed<br />
• Superior resealing properties<br />
• Soft, easily penetrated by syringe needle<br />
4607<br />
GENERAL PURPOSE BLUE SEPTA<br />
SIZE (O.D.) QTY PART NO. PRICE<br />
1/4" (6mm) 100 6512<br />
1/4" (6mm) 10 x 100 65122<br />
3/8" (9.5mm) 100 6514<br />
3/8" (9.5mm) 10 x 100 65142<br />
7/16" (11mm) 100 6518<br />
7/16" (11mm) 10 x 100 65182<br />
1/2" (12.5mm) 100 6520<br />
1/2" (12.5mm) 10 x 100 65202<br />
12" x 12" Sheet ea 6528<br />
XLB SEPTA<br />
SIZE (O.D.) QTY PART NO. PRICE<br />
1/4" (6mm) 50 15427<br />
3/8" (9.5mm) 50 15428<br />
7/16" (11mm) 50 15429<br />
1/2" (12.5mm) 50 15430<br />
21/32" (17mm) 50 15039<br />
General Purpose White Septa<br />
• Maximum temperature of 250°C<br />
• Lifetime of over 100 injections<br />
• Designed for use in 90% of all <strong>GC</strong> analysis<br />
4605<br />
HT-X High Performance Septa<br />
• Maximum temperature of 350°C<br />
• Long injection life - over 200 injections<br />
4604<br />
432<br />
GENERAL PURPOSE WHITE SEPTA<br />
SIZE (O.D.) QTY PART NO. PRICE<br />
3/8" (9.5mm) 50 7812<br />
3/8" (9.5mm) 2 x 50 78101<br />
7/16" (11mm) 50 7813<br />
7/16" (11mm) 2 x 50 78111<br />
1/2" (12.5mm) 50 7816<br />
1/2" (12.5mm) 2 x 50 78141<br />
ThermoRed Septa<br />
• Maximum temperature of 300°C<br />
• Packed in glass jars under strict QC<br />
standards to protect from contaminants<br />
THERMORED SEPTA<br />
SIZE (O.D.) QTY PART NO. PRICE<br />
11/32'' (9mm) 25 15129<br />
3/8'' (9.5mm) 25 15131<br />
7/16'' (11mm) 25 15132<br />
1/2" (12.5mm) 25 15141<br />
21/32'' (17mm) 25 15133<br />
Plug Type (For Shimadzu & SRI) 25 15134<br />
Standard Blue Septa<br />
• Maximum temperature of 300°C<br />
• Lifetime of over 50 injections<br />
STANDARD BLUE SEPTA<br />
SIZE (O.D.) QTY PART NO. PRICE<br />
3/8" (9.5mm) 100 7824<br />
7/16" (11mm) 100 7826<br />
1/2" (12.5mm) 100 7830<br />
© Copyright 2004 Alltech Associates, Inc.<br />
4608<br />
4601<br />
HT-X HIGH PERFORMANCE SEPTA<br />
SIZE (O.D.) QTY PART NO. PRICE<br />
1/4" (6mm) 50 15490<br />
5/16" (8mm) 50 15491<br />
3/8" (9.5mm) 50 15492<br />
7/16" (11mm) 50 15493<br />
21/32" (17mm) 50 154941<br />
1/2" (12.5mm) 50 15494<br />
12" x 12" Sheet ea 15496<br />
Plug Type (For Shimadzu & SRI) 50 15498<br />
Cylindrical Septa<br />
• 8mm Long x 6mm o.d.<br />
with half-hole<br />
The standard half-hole septa is red silicone with an<br />
upper temperature limit of 225°C. 3-layer septa features<br />
the shielding and reinforcing properties of PTFE. The<br />
plug septa are low bleed, have an upper temperature<br />
limit of 350°C, and are compatible with Shimadzu and<br />
SRI.<br />
CYLINDRICAL SEPTA<br />
SIZE (O.D.) QTY PART NO. PRICE<br />
Cylindrical Half-Hole Septa<br />
1/4" (6mm) 25 6524<br />
1/4" (6mm) 4 x 25 6526<br />
3 Layer 1/4" (6mm) 50 9602<br />
Cylindrical Plug Septa for<br />
Shimadzu and SRI<br />
50 15498<br />
Contact your Alltech office or distributor for current or local prices.<br />
4597<br />
Half-Hole Septa Shown Here
G C A C C E S S O R I E S<br />
Septa<br />
Septa<br />
Three- and Four-Layer Septa<br />
• Excellent sealing characteristics<br />
• Maximum temperature of 300ºC (3-layer) and 225ºC<br />
(4-layer)<br />
The Three-Layer Septa consists of a layer of red<br />
silicone rubber, a layer of translucent soft silicone rubber<br />
and another layer of red silicone rubber. The Four-Layer<br />
Septa is the same but with a 10-mil (0.010") PTFE<br />
facing.<br />
Microsep ® PTFE-Lined Septa<br />
• Maximum temperature of 250ºC<br />
• Off-white silicone rubber with an ivory PTFE backing<br />
4593<br />
3-Layer Septa<br />
4595 4594<br />
THREE- AND FOUR-LAYER SEPTA<br />
Hamilton Three-Layer Septa<br />
• Maximum temperature of 200ºC<br />
4-Layer Septa<br />
SIZE (O.D.) QTY. PART NO. PRICE<br />
Three-Layer Septa<br />
3/8" (9.5mm) 100 7836<br />
7/16" (11mm) 100 7838<br />
1/2" (12.5mm) 100 7840<br />
Four-Layer Septa<br />
3/8" (9.5mm) 100 7844<br />
7/16" (11mm) 100 7846<br />
1/2" (12.5mm) 100 7848<br />
These septa feature a center layer of soft silicone<br />
rubber for good resealing and two harder rubber outer<br />
layers for long life. The soft inner layer clings to the<br />
syringe needle and returns quickly to its original shape<br />
when the needle is withdrawn to prevent “blow back”.<br />
MICROSEP ® PTFE-LINED SEPTA<br />
SIZE (O.D.) QTY. PART NO. PRICE<br />
0.250" (6mm) 12 75801<br />
0.250" (6mm) 100 79391<br />
0.281" (7mm) 12 75810<br />
0.355" (9mm) 12 75803<br />
0.375" (9.5mm) 12 75804<br />
0.375" (9.5mm) 100 79411<br />
0.394" (10mm) 12 75805<br />
0.394" (10mm) 100 79451<br />
0.438" (11mm) 12 75807<br />
0.438" (11mm) 100 79471<br />
0.469" (12mm) 12 75813<br />
0.500" (12.5mm) 12 75806<br />
0.500" (12.5mm) 100 79491<br />
Microsep ® Low-Bleed PTFE-Lined Septa<br />
• Maximum temperature of 250ºC<br />
• Off-white silicone septa with yellow PTFE backing<br />
4591<br />
HAMILTON THREE-LAYER SEPTA<br />
SIZE (O.D.) QTY. PART NO. PRICE<br />
0.197" (5mm) 12 76022<br />
0.250" (6.35mm) 12 76001<br />
0.281" (7mm) 12 76010<br />
0.312" (8mm) 12 76002<br />
0.355" (9.0mm) 12 76003<br />
0.375" (9.5mm) 12 76004<br />
0.394" (10.0mm) 12 76005<br />
0.438" (11mm) 12 76007<br />
0.469" (12mm) 12 76013<br />
0.500" (12.7mm) 12 76006<br />
0.594" (15mm) 12 76016<br />
0.750" (19.0mm) 12 76020<br />
© Copyright 2004 Alltech Associates, Inc.<br />
4596<br />
MICROSEP ® LOW-BLEED PTFE-LINED SEPTA<br />
SIZE (O.D.) QTY. PART NO. PRICE<br />
3/8" (9.5mm) 50 7802<br />
3/8" (9.5mm) 2 x 50 78001<br />
3/8" (9.5mm) 20 x 50 78002<br />
7/16" (11mm) 50 7803<br />
7/16" (11mm) 2 x 50 78011<br />
7/16" (11mm) 20 x 50 78012<br />
1/2" (12.5mm) 50 7806<br />
1/2" (12.5mm) 2 x 50 78041<br />
1/2" (12.5mm) 20 x 50 78042<br />
Contact your Alltech office or distributor for current or local prices.<br />
433
Septa<br />
G C A C C E S S O R I E S<br />
434<br />
JADE Mechanical Inlet<br />
Injection Kits<br />
• Models available to accommodate 39 different inlets<br />
from 16 different manufacturers<br />
• No need to modify your existing <strong>GC</strong><br />
• Temperature limit up to 400°C set point (with Hi-<br />
Temp Needle Guide)<br />
• Cost effective and reliable<br />
© Copyright 2004 Alltech Associates, Inc.<br />
2808 2809<br />
The JADE Mechanical Inlet works like a miniature<br />
airlock. First, the syringe needle passes through a<br />
needle guide forming an annular seal. Next, the needle<br />
guide encounters the ball-and-seat valve, unseats the<br />
ball, and enters the injection port. When the needle is<br />
removed from the ball valve, a powerful return magnet<br />
pulls the ball back onto the seat, sealing the injection<br />
port.<br />
The elegantly simple ball-and-seat is the system’s<br />
most technologically complex component. For the<br />
utmost in reliability, it uses sophisticated materials<br />
and close tolerances found in the most advanced<br />
instrumentation.<br />
The JADE Inlet’s long lifetime, heat resistance, and<br />
low-maintenance design make it the obvious solution<br />
for autosampling. After the JADE Inlet is installed,<br />
there’s minimal need for operator attention, enabling<br />
chromatographers to focus on more important tasks<br />
instead of monitoring septum failure.<br />
Ultimately, the JADE Inlet serves as a vital link<br />
in implementing online <strong>GC</strong> applications where system<br />
longevity, reliability, and low maintenance are absolute<br />
requirements.<br />
Each JADE Inlet Kit Includes:<br />
- JADE Inlet Injector (complete with needle guide)<br />
- Adapter for <strong>GC</strong> inlet with gasket(s)<br />
- Extra needle guide<br />
- Spare gasket for adapter<br />
- Two 10µL syringes for sample injection<br />
- “BAKE-OUT” plug for cleaning inlet before installation<br />
- Complete instructions<br />
JADE MECHANICAL INLET INJECTION KITS<br />
0.47MM<br />
PART NO.<br />
0.63MM<br />
PART NO.<br />
HP/Agilent<br />
5830/5840 9774 9788<br />
5880/5890/6890 Split/Splitless 9764 9778<br />
5880/5890/6890 Packed 9762 9776<br />
5710/5790 Packed 9774 9788<br />
5700 Capillary 9764 9778<br />
5993 <strong>GC</strong>/MS 9764 9778<br />
5890 Purged/Packed 9909 9683<br />
Cool/On-Column (0.53mm i.d.) 9755 —<br />
HP/Agilent Autosamplers*<br />
7673A&B Split/Splitless — 9925<br />
7673A&B Packed — 9927<br />
7673A&B Purged/Packed — 9198<br />
Carlo-Erba (Except TRACE 2000) 9750 9752<br />
Chrompack 9774 9788<br />
Dani (All Models) 9754 9756<br />
Dionex (602D) 8850 8852<br />
Finnigan (9610/9611 Series) 9751 9753<br />
Fisons (Series 8000) 9033 9178<br />
Gow-Mac (All Models) 9774 9788<br />
HNU Systems (3000 Series) 9774 9788<br />
Konik (HR<strong>GC</strong> 3000C) 9774 9788<br />
Perkin Elmer*<br />
2000/8300/8700/8500 Sigma Series 9774 9788<br />
Shimadzu<br />
8/9/14A and 15A Packed 9738 9732<br />
14A and 15A Split/Splitless 9736 9730<br />
17A Split/Splitless 7268 8014<br />
Siemens<br />
Temp. Programmed Injector 9735 9737<br />
SRI (Split & Packed) 8858 8860<br />
Tracor/Tremetrics<br />
540/570 Series 9739 9747<br />
560/565 Series 8950 8984<br />
9000 Series 9959 9962<br />
ThermoQuest<br />
Trace <strong>GC</strong> 7258 7260<br />
<strong>GC</strong>Q 7189 7196<br />
Varian**<br />
1040 Packed 9748 9734<br />
1075/1077/1078/1079 Split/Splitless 9768 9786<br />
1075/1077/1078/1079 Split/Splitless 9193 9195<br />
with Trigger<br />
1085 9197 9199<br />
1093/1094 SPI Injector with Trigger 9689 9699<br />
1400/2400/2700 Series 9921 9923<br />
3400/3700 Capillary, 1cm Septum 9768 9786<br />
3400/3700 Capillary, 8mm Septum 9748 9734<br />
3300 Capillary 9768 9786<br />
Universal<br />
7/16" x 20 Swagelok ® Thread 9774 9788<br />
Econo Kit † — 97505<br />
* JADE Inlet is incompatible with HP 6890 autosamplers and Perkin Elmer<br />
autosampler.<br />
**JADE Inlets are compatible with Varian Star autosamplers, but may be<br />
incompatible with other Varian models.<br />
†<br />
Includes inlet body, green cap and 0.63mm needle guide. Adapter nut not<br />
included.<br />
JADE Inlets are also available for SPME.<br />
Request datasheet 9778.<br />
PRICE<br />
Contact your Alltech office or distributor for current or local prices.
G C A C C E S S O R I E S<br />
Septa<br />
The JADE Mechanical Inlet<br />
Installing a JADE Inlet*<br />
Precision-made,<br />
tapered needle<br />
guide<br />
Durable hard<br />
anodized finish<br />
1 2<br />
Ball magnet<br />
return<br />
High precision<br />
balls provide<br />
perfect sealing<br />
US. Patent #5,062,310<br />
Replacement Parts<br />
Ball seat<br />
No-bleed high<br />
temperature<br />
gasket seals off<br />
<strong>GC</strong> port<br />
6252<br />
2208<br />
After removal of the<br />
septum nut and septum,<br />
clean out old septum<br />
particles. A polyimide<br />
gasket (included) is placed<br />
in the septum well.<br />
3 4<br />
2209<br />
The adapter nut is threaded<br />
on to the injection port<br />
finger tight.<br />
DESCRIPTION<br />
REPLACEMENT JADE INLET NEEDLE GUIDES<br />
REPLACEMENT JADE INLET GASKETS<br />
DESCRIPTION QTY. PART NO. PRICE<br />
HP/Agilent<br />
Cool/On-Column 2 9688<br />
5830/5840/5880/5890/6890 2 9763<br />
HP/Agilent Autosamplers<br />
5880/5890 and 7673A&B Capillary 2 9759<br />
5880/5890 and 7673A&B Packed 2 9761<br />
Carlo Erba 2 9666<br />
Dani 2 9684<br />
Finnigan 9610/9611 2 9686<br />
Fisons 8000 2 7911<br />
Gow Mac 2 9763<br />
Packard 2 9763<br />
Perkin Elmer 2000/8300/8500/8700 2 9763<br />
Shimadzu (all) 2 9789<br />
Siemens<br />
Capillary 2 7989<br />
TP 2 7991<br />
ThermoQuest<br />
Trace <strong>GC</strong> 2 7266<br />
<strong>GC</strong>Q 2 7236<br />
Tracor<br />
540/570 2 7992<br />
560/565 2 7264<br />
9000 2 7993<br />
Varian<br />
1075/1077/1078/1079 2 9795<br />
1040/3400/3700 2 9796<br />
1093/1094 2 7994<br />
1400/2400/2700 2 7996<br />
Universal 2 9763<br />
© Copyright 2004 Alltech Associates, Inc.<br />
0.47MM<br />
PART NO.<br />
0.63MM<br />
PART NO.<br />
Standard, Up to 350°C 9790 9794<br />
Hi-Temp, 250°C - 400°C 9792 9797<br />
PRICE<br />
*Note: The instructions are for installation on a Agilent/Hewlett-Packard<br />
injection port. Installation may vary slightly for other instruments.<br />
2210<br />
A one-time bake-out step<br />
is recommended to remove<br />
residual septum materials<br />
from the injection port.<br />
The brass bake-out plug<br />
(included) is installed on<br />
the adapter nut for this<br />
step. The bake-out plug is<br />
removed when done.<br />
Syringes for JADE Inlets<br />
NEEDLE<br />
TYPE<br />
SYRINGES FOR JADE INLETS<br />
NEEDLE<br />
HAMILTON<br />
PART NO.<br />
Contact your Alltech office or distributor for current or local prices.<br />
2211<br />
The JADE Inlet body is<br />
threaded into the adapter<br />
nut finger tight. With<br />
the appropriate wrench in<br />
place on the adapter nut,<br />
tighten the valve body 1/4<br />
to 1/2 turn using a 1/2"<br />
wrench. The completely<br />
assembled JADE Inlet is<br />
now ready for worry-free<br />
operation.<br />
SGE<br />
PART NO.<br />
VOLUME<br />
O.D.<br />
PRICE<br />
PRICE<br />
Manual Injection Syringes<br />
0.5µL RN 0.63mm 86240 — —<br />
1.0µL RN 0.63mm 801400 85372<br />
1.0µL RN 0.47mm 80141 — —<br />
10µL Fixed 0.63mm 80343 9942<br />
10µL Fixed 0.47mm 80344 85374<br />
Autosampler Syringes HP7673<br />
2.5µL Fixed 0.63mm — — 9658<br />
5.0µL Fixed 0.63mm 87948 85376<br />
5.0µL Fixed 0.47mm — — 85075<br />
5.0µL Fixed 0.63mm — — 85376<br />
5.0µL Fixed 0.47mm — — 85075<br />
4907<br />
435
Septa<br />
G C A C C E S S O R I E S<br />
436<br />
Septa <strong>Accessories</strong><br />
Merlin Microseal Septum<br />
• Lasts for thousands<br />
of injections<br />
• No instrument<br />
modification needed<br />
• Installation as<br />
easy as changing a<br />
standard septum<br />
• High pressure model allows operation up to 100psig<br />
The Merlin Microseal Septum is a long-life<br />
replacement for the septum and septum nut on the<br />
capillary inlet system of an Agilent <strong>GC</strong>. It incorporates<br />
two sequential seals to provide a much longer period of<br />
use between seal changes. Use the Merlin Microseal <br />
with the HP 7673 Autosampler to allow many more<br />
samples to be run unattended while reducing the risk<br />
of lost or compromised data caused by septum leaks<br />
or fragmentation. It also allows for easier manual<br />
injections.<br />
The Microseal Septum lasts longest when a syringe<br />
needle with a truncated cone shaped tip is used. It<br />
may also be used with the standard 0.63mm diameter<br />
(0.026", 23-gauge) needle recommended for use with the<br />
HP 7673 Autosampler.<br />
MERLIN MICROSEAL SEPTUM*<br />
DESCRIPTION PART NO. PRICE<br />
Microseal Septum Kits<br />
For HP/Agilent <strong>GC</strong>s<br />
Microseal Nut and 2 Septa 80060<br />
Microseal Nut and 1 Septum 80062<br />
Microseal High Pressure Septum Kits<br />
Standard Kit, Nut and 2 Septa 80190<br />
Starter Kit, Nut and 1 Septum 80192<br />
For Varian 1078 & 1079 <strong>GC</strong>s with SPME Injector<br />
Varian Kit, Nut with start switch, 1 septum<br />
and o-ring<br />
80031<br />
Replacement Parts<br />
For HP/Agilent <strong>GC</strong>s<br />
Microseal Septum, ea 80063<br />
Microseal High Pressure Septum, ea 80194<br />
Microseal High Pressure Nut, ea 80196<br />
For Varian 1078 & 1079 <strong>GC</strong>s with SPME Injector<br />
Microseal High Pressure Septum, ea 80035<br />
*Regular Merlin Microseal has a 30psig limit. High Pressure Merlin Microseal <br />
has a 100psig limit.<br />
Septum Remover<br />
90º hooked point allows for safe septum removal.<br />
Aluminum body. 8" length.<br />
SEPTUM REMOVER<br />
DESCRIPTION PART NO. PRICE<br />
Septum Remover 24030<br />
© Copyright 2004 Alltech Associates, Inc.<br />
5070<br />
4584<br />
Septa-Out<br />
Safely extract cylindrical septa<br />
without the danger of breaking your<br />
glass column or sampling bulb port.<br />
Heat Resistant Gloves<br />
• Protect your hands from burns<br />
• Heavyweight cotton/Kevlar ®<br />
combination<br />
Knit construction offers superior<br />
comfort and lessens hand fatigue.<br />
Gloves are ambidextrous and feature a<br />
glove-within-a-glove design.<br />
Inlet Pressure Gauge<br />
Insert the needle directly into the inlet<br />
of any gas chromatograph for direct pressure<br />
measurement. The small, 0.028" o.d. needle<br />
permits repeated inlet pressure checks without<br />
damage to the septum.<br />
Septum Needle Guide<br />
SEPTA-OUT<br />
DESCRIPTION PART NO. PRICE<br />
Septa-Out 6412<br />
HEAT RESISTANT GLOVES<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Heat Resistant Gloves pr 2906<br />
INLET PRESSURE GAUGE<br />
DESCRIPTION PART NO. PRICE<br />
0-30psig 86805<br />
0-60psig 86806<br />
0-100psig 86807<br />
0-200psig 86808<br />
Replacement Needle Assembly 18260<br />
This septum needle guide helps<br />
reduce bent syringe needles and<br />
extends septum life. With the<br />
septum needle guide you get double leak protection.<br />
A cylindrical septum acts as a double seal should your<br />
primary septum start leaking. Needle guide is selfcentering<br />
to aid in on-column injection.<br />
SEPTUM NEEDLE GUIDE<br />
DESCRIPTION PART NO. PRICE<br />
Needle Guide, 7/16" x 20 Thread* 6401<br />
Needle Guide, 7/16" x 24 Thread 6403<br />
Needle Guide without Nut 6400<br />
Drill Bit for Enlarging Hole 6402<br />
Replacement Cylindrical Septa, 25/pk 6524<br />
*Fits most injection ports including: PE-3920 and Sigma Series; HP5700, 5800,<br />
and 6900 Series (5890 and 6890).<br />
Contact your Alltech office or distributor for current or local prices.<br />
4585<br />
4582<br />
4588<br />
4583
G C A C C E S S O R I E S<br />
Organizers and Tools<br />
Organizers and Tools<br />
<strong>GC</strong> Column and Accessory Organizers<br />
Keep all your high-use columns readily available and<br />
protected with these 5-column or 10-column storage<br />
units. Both units feature a covered 7-bin, small-parts<br />
storage on top. Larger tools can be stored in the tool<br />
holder on the side. Columns are easy to remove and ID<br />
tags are readily visible.<br />
5-Column Organizer<br />
14L x 13H x 10.5"W<br />
(35.5L x 33H x 26.5cmW)<br />
5688 5687<br />
10-Column Organizer<br />
25L x 12.75H x 10.5"W<br />
(63.5L x 32H x 26.5cmW)<br />
Organizer Box<br />
These organizers are ideal<br />
for storing small parts such as<br />
septa, ferrules, and fittings.<br />
The 9-compartment organizer<br />
includes eight 1-3/8" x 1-5/8"<br />
slots and one 1-1/8" x 3-1/4"<br />
slot. The 18-compartment<br />
organizer includes twelve 2" x 2" slots<br />
and six 2" x 4-3/16" slots.<br />
Capillary Magnifiers<br />
ORGANIZER BOX<br />
DESCRIPTION PART NO. PRICE<br />
9-Compartment Box 6264<br />
18-Compartment Box 6266<br />
These magnifiers are ideal for inspecting the ends<br />
of capillary columns. The lighted magnifier includes a<br />
battery.<br />
5772<br />
<strong>GC</strong> COLUMN AND ACCESSORY ORGANIZERS<br />
DESCRIPTION PART NO. PRICE<br />
<strong>GC</strong> Column Organizer, 5-Column 6390<br />
<strong>GC</strong> Column Organizer, 10-Column 6392<br />
20X Magnifier<br />
5325 2156<br />
Lighted Magnifying Glass<br />
Drawer Organizer<br />
This compact organizer<br />
features 30 drawers for storing<br />
all of your small parts and<br />
accessories. Clear plastic drawers<br />
are 1-1/8"L x 2"W x 4-5/8"D<br />
and can be easily labeled.<br />
Overall organizer dimensions are<br />
8-1/4"L x 11-1/4"W x 5-1/8"D.<br />
5270<br />
Gas Torch<br />
CAPILLARY MAGNIFIERS<br />
DESCRIPTION PART NO. PRICE<br />
20X Magnifier 3163<br />
Lighted Magnifier 3196<br />
Ideal for sealing the ends of capillary<br />
columns. Basic kit contains the torch, two<br />
Micronox cylinders, one butane cylinder,<br />
three silver soldering rods, flux tube, two<br />
flame tips and complete instructions.<br />
5181<br />
Adjustable Organizer<br />
DRAWER ORGANIZER<br />
DESCRIPTION PART NO. PRICE<br />
Drawer Organizer 6260<br />
This extra-large organizer<br />
has 14 adjustable dividers<br />
and 4 shelves for convenient<br />
access to common lab supplies.<br />
PVC construction is chemically<br />
resistant and makes cleaning<br />
easy. 20"H x 24"W x 10.5"D<br />
ADJUSTABLE ORGANIZER<br />
DESCRIPTION PART NO. PRICE<br />
Adjustable Organizer 5242<br />
© Copyright 2004 Alltech Associates, Inc.<br />
5509<br />
Heat Gun<br />
GAS TORCH<br />
DESCRIPTION PART NO. PRICE<br />
Basic Torch Kit 14600<br />
Cylinder Kit (4 Micronox and 2 Butane) 14601<br />
Micronox Cylinders, 6/pk 14602<br />
Butane Cylinders, 6/pk 14603<br />
Piercing Knob, Butane 14604<br />
Piercing Knob, Micronox 14605<br />
Ideal for heating polyimide<br />
sealing resin when connecting<br />
capillaries and guard columns. Gun<br />
heats to 350ºC, features a 3-position<br />
switch (off/cool/hot) and includes an adjustable stand.<br />
HEAT GUN<br />
DESCRIPTION PART NO. PRICE<br />
120VAC, 4.5A, 60Hz 2518<br />
220VAC, 2.0A, 50/60Hz 2518-220V<br />
Contact your Alltech office or distributor for current or local prices.<br />
6691<br />
437
Tools<br />
G C A C C E S S O R I E S<br />
Tools<br />
Capillary Tool Kit<br />
Autoranging Digital Multimeter<br />
Kit includes diamond scriber,<br />
2 open end wrenches, PTFE<br />
coated forceps, ruler, ferrule<br />
pick, 10' high temperature<br />
string, 20X magnifier, and pipe<br />
cleaner.<br />
5179<br />
Unit has a 1/2" 3-3/4 digit LCD.<br />
Measures DCV, ACV, OHM, DC current, AC<br />
current, frequency plus diode check and<br />
continuity test. Uses 1-9V battery.<br />
6779<br />
CAPILLARY TOOL KIT<br />
DESCRIPTION PART NO. PRICE<br />
Capillary Tool Kit 16879<br />
23-Piece Tool Kit in Zippered Case<br />
AUTORANGING DIGITAL MULTIMETER<br />
DESCRIPTION PART NO. PRICE<br />
Autoranging Digital Multimeter 25970<br />
9-Way Cylinder Wrench<br />
Kit includes 7 screwdrivers,<br />
adjustable wrench, 2 pliers,<br />
wire stripper, knife, alignment<br />
tool, stainless rule, hex key set,<br />
scissors, 2 flexible files, burnisher,<br />
miniature soldering iron, solder<br />
aid, coil of solder, and desoldering braid.<br />
5323<br />
9-WAY CYLINDER WRENCH<br />
DESCRIPTION PART NO. PRICE<br />
9-Way Cylinder Wrench 412933<br />
5178<br />
Adjustable Wrench<br />
• Chrome-Plated<br />
Open-End Wrench<br />
• Chrome-Plated<br />
23-PIECE TOOL KIT IN ZIPPERED CASE<br />
DESCRIPTION PART NO. PRICE<br />
23-Piece Tool Kit and Case 16533<br />
ADJUSTABLE WRENCH<br />
DESCRIPTION PART NO. PRICE<br />
4" Long – 1/2" Capacity 16549<br />
6" Long – 3/4" Capacity 3211<br />
8" Long – 7/8" Capacity 16522<br />
OPEN-END WRENCH<br />
DESCRIPTION PART NO. PRICE<br />
1/4" x 5/16" – Fits 1/16" Fitting Nuts 1998<br />
7/16" x 1/2" – Fits 1/8" & 3/16" Fitting Nuts 1999<br />
9/16" x 5/8" – Fits 1/4" & 3/8" Fitting Nuts 2000<br />
5322<br />
5321<br />
Miniature Files, Fine Cut<br />
Set includes six different<br />
shaped, 5-1/2" long files.<br />
They are made of hard chrome<br />
steel suitable for smoothing<br />
and deburring.<br />
Miniature Reamers<br />
Set includes six different sizes:<br />
0.028"/0.018", 0.040"/0.026",<br />
0.048"/0.032", 0.080"/0.050",<br />
0.085"/0.053", 0.104"/0.062".<br />
Flame Checker<br />
Pivoting mirror head fogs<br />
when flame is lit.<br />
MINIATURE FILES<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Miniature Files, Fine Cut 6/pk 7237<br />
MINIATURE REAMERS<br />
DESCRIPTION QTY. PART NO. PRICE<br />
Miniature Reamers 6/pk 7330<br />
6279<br />
5324<br />
438<br />
© Copyright 2004 Alltech Associates, Inc.<br />
FLAME CHECKER<br />
DESCRIPTION PART NO. PRICE<br />
Flame Checker 7047<br />
Contact your Alltech office or distributor for current or local prices.<br />
5715
G C A C C E S S O R I E S<br />
Valves<br />
Flow Control Valves<br />
Valve Selection Guide<br />
Toggle Valves<br />
Ball Valves<br />
Toggle valves are designed<br />
primarily as on-off valves for<br />
low pressure applications (less<br />
than 250 psig). The handle<br />
position provides a quick<br />
verification of the on/off<br />
status.<br />
5228<br />
Ball valves are designed<br />
to throttle or shut off liquid<br />
and gas lines in high pressure<br />
applications (1500-2500psig).<br />
They are available in 2-way or<br />
3-way configurations.<br />
5230<br />
Plug Valves<br />
Plug valves are designed<br />
to throttle or shut off liquid<br />
and gas lines in intermediate<br />
pressure applications (less<br />
than 500 psig). They generally<br />
have a higher temperature<br />
limit than ball or toggle<br />
valves.<br />
5231<br />
Metering Valves<br />
Metering valves are multiturn<br />
valves designed to<br />
regulate gas flow.<br />
For order information on Plug Valves, Ball Valves<br />
and Metering Valves, see page 440.<br />
5238<br />
Parker Toggle Valves<br />
These forged-body valves are<br />
positive, soft-seat shut-off valves<br />
designed for quick opening and<br />
closing. Shut-off force is constant<br />
because of the spring load. The<br />
handle locks in the open or closed<br />
position. A TFE stem tip provides<br />
a leak-tight seal. The maximum<br />
working pressure is 250psig;<br />
Part No. 2328<br />
maximum temperature is 93°C.<br />
They are made of brass or 316 stainless steel with TFE<br />
seat, Viton ® packing and nylon handle. All other parts<br />
are 316 stainless steel.<br />
Hoke Toggle Valves<br />
These valves feature a simple,<br />
reliable, low-maintenance design<br />
that is well suited for a wide<br />
variety of applications. They<br />
are made of brass or stainless<br />
steel and include long-lasting<br />
Viton ® seat and o-ring packing<br />
for positive pressure or vacuum<br />
applications. The maximum<br />
operating pressure is 200psig<br />
and the maximum operating<br />
temperature is 149°C.<br />
5225 5259<br />
Part No. 12131<br />
PARKER TOGGLE VALVES<br />
DESCRIPTION PART NO. PRICE<br />
1/8" Brass 2328<br />
1/4" Brass 2332<br />
1/8" SS 2336<br />
1/4" SS 2340<br />
HOKE TOGGLE VALVES<br />
DESCRIPTION PART NO. PRICE<br />
Straight Toggle Valves<br />
1/8" Brass 12131<br />
1/4" Brass 12133<br />
1/8" SS 12132<br />
1/4" SS 12134<br />
Angled Toggle Valves<br />
1/8" Brass 12135<br />
1/4" Brass 12136<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
439
Valves<br />
G C A C C E S S O R I E S<br />
Flow Control Valves<br />
Nupro and Whitey Plug and Ball Valves<br />
The plug valves are constructed of brass or stainless<br />
steel and TFE. The compact plug valves can be used up<br />
to 3000psig and the temperature limit is 200°C. They<br />
have a plug orifice of 0.172" for high flow capacity.<br />
The 2-way and 3-way ball valves can be used up to<br />
65°C and are pressure-rated to 2500psig. Both can be<br />
panel-mounted in a 19/32" hole. The 1/8" valves have<br />
a 0.093" orifice while the 1/4" valves have a 0.125"<br />
orifice.<br />
Hoke Plug and Ball Valves<br />
The plug valves are constructed of brass or stainless<br />
steel and PTFE. They have an upper pressure limit of<br />
3000psig and an upper temperature limit of 205°C. They<br />
have a plug orifice of 0.093".<br />
The 2-way ball valves are made of brass or stainless<br />
steel and PTFE. They have an upper temperature limit of<br />
179°C and an upper pressure limit of 1500psig. The 1/8"<br />
version has a 0.093" orifice while the 1/4" version has a<br />
0.187".<br />
The 3-way ball valves are made of brass or stainless<br />
steel and PTFE/Nylatron ® . They have an upper pressure<br />
limit of 500psig and an upper temperature limit of<br />
179°C. Both sizes have a 0.187" orifice.<br />
5232 5233 5234<br />
Part No. 14320 Part No. 14318 Part No. 14316<br />
440<br />
DESCRIPTION<br />
NUPRO AND WHITEY PLUG AND BALL VALVES<br />
PLUG<br />
VALVE<br />
PART NO.<br />
PRICE<br />
5235<br />
NUPRO AND WHITEY FINE METERING VALVES<br />
DESCRIPTION PART NO. PRICE<br />
Straight Pattern<br />
1/8", Brass 8600<br />
1/4", Brass 8602<br />
1/8", SS 8604<br />
1/4", SS 8606<br />
Angle Pattern<br />
1/8", Brass 8608<br />
1/4", Brass 8610<br />
1/8", SS 8612<br />
1/4", SS 8614<br />
© Copyright 2004 Alltech Associates, Inc.<br />
2-WAY<br />
BALL VALVE<br />
PART NO.<br />
PRICE<br />
3-WAY<br />
BALL VALVE<br />
PART NO.<br />
1/8", Brass 14320 14318 14316<br />
1/4", Brass 14319 14317 14315<br />
1/8", SS 16013 16017 16022<br />
1/4", SS 16015 16019 16024<br />
Nupro and Whitey Fine Metering Valves<br />
5261<br />
PRICE<br />
These valves give extremely fine control in the 0-<br />
400cc/minute gas flow range. The maximum pressure<br />
rating is 1000psig at 70°C. The maximum temperature<br />
limit for brass valves is 150°C; 200°C for stainless steel.<br />
They can be panel mounted in a 37/64" hole.<br />
Angle<br />
Part No. 8612<br />
5262 5260 5263<br />
Part No. 12126 Part No. 12119 Part No. 12123<br />
DESCRIPTION<br />
PLUG<br />
VALVE<br />
PART NO.<br />
HOKE PLUG AND BALL VALVES<br />
PRICE<br />
2-WAY<br />
BALL VALVE<br />
PART NO.<br />
PRICE<br />
Hoke Fine Metering Valves with Vernier Knob<br />
These valves allow reproducibility<br />
of precise flows. All valves use a TFE<br />
seat seal and packing. Brass valves are<br />
rated at 3000psig; stainless steel at<br />
5000psig. Temperatures up to 230°C<br />
can be used but at lower pressures.<br />
HOKE FINE METERING VALVES<br />
3-WAY<br />
BALL VALVE<br />
PART NO.<br />
1/8", Brass 12126 12118 12122<br />
1/4", Brass 12128 12120 12124<br />
1/8", SS 12127 12119 12123<br />
1/4", SS 12129 12121 12125<br />
Plug Valve Repair Kit 12130<br />
Straight<br />
Part No. 8604 Part No. 86001<br />
DESCRIPTION PART NO. PRICE<br />
Straight Pattern<br />
1/8", Brass 86001<br />
1/4", Brass 86021<br />
1/8", SS 86041<br />
1/4", SS 86061<br />
Angle Pattern<br />
1/8", Brass 86081<br />
1/4", Brass 86101<br />
1/8", SS 86121<br />
1/4", SS 86141<br />
PRICE<br />
Contact your Alltech office or distributor for current or local prices.<br />
5264
G C A C C E S S O R I E S<br />
Valves<br />
Alltech <strong>GC</strong>/MS Switching Valve<br />
Switch Between Columns with the Turn of a Valve<br />
• Replace columns<br />
without <strong>GC</strong>/MS<br />
shutdown<br />
• Protect and maintain<br />
flow path integrity<br />
• Compatible with any<br />
<strong>GC</strong>/MS system<br />
• Installs quickly and<br />
easily<br />
Alltech’s <strong>GC</strong>/MS<br />
6239<br />
switching valve<br />
eliminates long downtimes associated with column<br />
changes. Use the valve as a bypass valve to supply<br />
continuous carrier gas to the MS while changing a<br />
column in a single injector system or to switch between<br />
two columns from two injection ports to one MS.<br />
The <strong>GC</strong>/MS switching valve is easy to install. Simply<br />
place the valve directly in the <strong>GC</strong> oven, connect the<br />
capillary columns and transfer lines to the appropriately<br />
labeled ports and the valve is ready to use.<br />
<strong>GC</strong>/MS Switching Valve Specifications<br />
Temperature Range: Ambient to 350°C<br />
Maximum Pressure:<br />
25psig<br />
Connections:<br />
Zero Dead Volume<br />
Compatible Column Sizes: 0.25mm or 0.32mm i.d.<br />
<strong>GC</strong>/MS SWITCHING VALVE<br />
DESCRIPTION QTY. PART NO. PRICE<br />
<strong>GC</strong>/MS Switching Valve<br />
For 0.25mm i.d. ea 12325<br />
For 0.32mm i.d. ea 12327<br />
Replacement Parts<br />
Nuts, 1/32" 5 12317<br />
0.25mm Ferrule & Liner Set 5 12319<br />
0.32mm Ferrule & Liner Set 5 12324<br />
For more information on the <strong>GC</strong>/MS Switching Valve,<br />
request IS037. Also available on our website.<br />
SGE ms-NoVent Valve<br />
Prevents Air and Water from Entering the MS during Column Changeover<br />
• Simple operation<br />
• Direct <strong>GC</strong>/MS<br />
interface<br />
• Save 6-12 hours<br />
The ms-NoVent is<br />
a fluidic valve that can<br />
be retrofitted to any <strong>GC</strong><br />
mass spectrometer. It<br />
5689<br />
allows column changeover without the need to vent the<br />
MS resulting in a time saving of 6-12 hours. The unique<br />
design ensures a helium purge maintains a positive flow<br />
from the valve, to the atmosphere, when a column is not<br />
connected. Certain <strong>GC</strong>/MS models require a restrictor to<br />
be ordered separately at right.<br />
SGE MS-NOVENT <br />
DESCRIPTION PART NO. PRICE<br />
ms-NoVent <br />
Suitable for Varian, Shimadzu, Perkin-Elmer,<br />
ThermoQuest, and HP/Agilent (all HP models<br />
including 5890 and 6890)<br />
113400<br />
ms-NoVent Restrictors<br />
Restrictor for HP5970 113405<br />
Restrictor for HP5971/5972 113407<br />
Restrictor for HP5973 113409<br />
Restrictor and Adapter for Varian Saturn 2000 113412<br />
Restrictor and Adapter for Shimadzu 5000/5050 113410<br />
Need Technical Assistance?<br />
Call Alltech Tech Support:<br />
Email: tech_service@alltechemail.com<br />
Online: www.alltechWEB.com<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.<br />
441
Valves<br />
G C A C C E S S O R I E S<br />
Valco ® Sampling/Switching Valves<br />
Zero Volume Fittings Allow for Direct Valve Connections<br />
• Easily adapt to any type of tubing<br />
• Eliminate pressure surges during sample injections<br />
• Carefully leak tested<br />
Valco ® sampling/switching valves are ideal for all <strong>GC</strong><br />
sample injections and flow switching applications. The<br />
low internal volume and uniform flow paths eliminate<br />
peak broadening and loss of resolution. Medium<br />
temperature valves have a limit of 175ºC and high<br />
temperature valves have a limit of 300ºC. Valves require<br />
sample loops—order separately on facing page.<br />
Valco ® valves feature zero volume fittings that allow<br />
tubing connections to the valve body without increasing<br />
the internal sample volume. Fittings also make direct,<br />
on-column injections possible. Replacement zero volume<br />
fittings are available on facing page.<br />
What’s included: zero-volume fittings, mounting<br />
bracket, and handle.<br />
4678<br />
Valco ® Sampling/Switching Valve Specifications<br />
Valve Body: Type 316 Stainless Steel Max. Temp: 175°C for medium temperature valves<br />
300°C for high temperature valves*<br />
Valve Seal: Carbon-filled PTFE (Medium Temp.) or<br />
Carbon-filled Polyimide (High Temp.)<br />
Active Ports: 3,4,6,8 or 10 Ports (Note: a 10-port valve can be used<br />
as a 6- or 8-port valve)<br />
Outlet Fitting:<br />
Max. Pressure:<br />
1/16" zero-volume fittings or<br />
1/8" zero-volume fittings (included)<br />
400psig<br />
Mounting: Valves supplied with angle mounting brackets for<br />
mounting on the side of the instruments or they can<br />
be flush mounted. Valves are tapped with 8-32TPI<br />
holes. Most <strong>GC</strong>s are designed to accept these valves.<br />
*Cannot be used below 200°C.<br />
VALCO ® SAMPLING/SWITCHING VALVES*<br />
DIAGRAM PORTS FITTINGS<br />
MEDIUM TEMP.<br />
VALVE PART NO.<br />
PRICE<br />
HIGH TEMP.<br />
VALVE PART NO.<br />
PRICE<br />
REPL. SHAFT & SEAL<br />
FOR MEDIUM TEMP.<br />
VALVE PART NO.<br />
PRICE<br />
0345<br />
3-Port 1/16" Zero Volume 9099 39099 290990<br />
1/8" Zero Volume 9101 39101 291010<br />
0346<br />
4-Port 1/16" Zero Volume 9103 39103 29103<br />
1/8" Zero Volume 9104 39104 29104<br />
2102<br />
6-Port 1/16" Zero Volume 9105 39105 29105<br />
1/8" Zero Volume 9110 39110 29110<br />
2103<br />
8-Port 1/16" Zero Volume 9115 39115 29115<br />
1/8" Zero Volume 9116 39116 29116<br />
2104<br />
10-Port 1/16" Zero Volume 9119 39119 29119<br />
1/8" Zero Volume 9120 39120 291200<br />
* By special order, valves can be fabricated from Hastalloy C ® . Call for pricing information.<br />
442<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Contact your Alltech office or distributor for current or local prices.
G C A C C E S S O R I E S<br />
Valves<br />
<strong>Accessories</strong> for Valco ® Sampling/Switching Valves<br />
Stainless Steel Sample Loops<br />
Zero Volume Fittings<br />
LOOP SIZE<br />
VALCO ® SS SAMPLE LOOPS*<br />
USE WITH<br />
1/16" VALVES<br />
PART NO.<br />
PRICE<br />
USE WITH<br />
1/8" VALVES<br />
PART NO.<br />
15µL 91056 91106<br />
25µL 91057 91107<br />
50µL 91058 91108<br />
100µL 91059 91109<br />
250µL 91050 91100<br />
500µL 91051 91101<br />
1.0mL 91052 91102<br />
2.0mL 91053 91103<br />
5.0mL 91054 91104<br />
10.0mL 91055 91105<br />
*One pair of nuts and ferrules are included.<br />
Valve Actuators<br />
PRICE<br />
The Valco ® 2-position helical actuators permit the<br />
application of controlled, constant torque for the<br />
actuation of rotary devices. Minimum actuation pressure<br />
is typically less than 30psig for operation of Valco ®<br />
sample injection and switching valves. Low internal<br />
leakage permits either pulsed or continuous operation<br />
with low gas consumption.<br />
Actuators are designed for room temperature<br />
operation, but high temperature versions are also<br />
available. Valves intended for mounting in ovens<br />
or heated detector zones are used with a stand-off<br />
assembly which locates the actuator out of the heated<br />
zone and supports both valve and actuator. Order a<br />
stand-off assembly separately below.<br />
Column<br />
Inlet<br />
DESCRIPTION<br />
Valve Body<br />
Adapter<br />
Valve Body<br />
ZERO VOLUME FITTINGS<br />
USE WITH<br />
1/16" VALVES<br />
PART NO.<br />
Adapters Shown in a Valve<br />
Slot<br />
.010" Orifice (.25mm)<br />
PRICE<br />
Sample<br />
Loop<br />
Fused Silica Tubing<br />
Nut<br />
Polyimide<br />
Ferrule<br />
Rotor<br />
USE WITH<br />
1/8" VALVES<br />
PART NO.<br />
Nuts, 5/pk 458015 458025<br />
Ferrules, 5/pk 458125 458155<br />
Fused Silica Adapters<br />
Fused silica adapters permit easy use of capillary<br />
columns with 1/16" Valco ® valves.<br />
Removable<br />
Polyimide<br />
Liner<br />
1577<br />
PRICE<br />
1578<br />
VALVE ACTUATORS<br />
DESCRIPTION PART NO. PRICE<br />
Air Actuators<br />
90° Air Actuator for 3-8 Port Valves and<br />
3,000psig HPLC Valve<br />
60° Air Actuator for 10 Port Valves and<br />
7,000psig HPLC Valve<br />
90° Hi-Temp Air Actuator for 3-8 Port and<br />
3,000psig HPLC Valves<br />
© Copyright 2004 Alltech Associates, Inc.<br />
9121<br />
9122<br />
91211<br />
Air Switch for Air Actuators, 110V 9123<br />
Air Switch for Air Actuators, 220V 9124<br />
DVI-Digital Valve Interface 1391<br />
6" Stand-Off Assembly 91216<br />
<br />
<br />
<br />
<br />
<br />
FUSED SILICA ADAPTERS<br />
<br />
DESCRIPTION PART NO. PRICE<br />
Fused Silica Adapter for:<br />
0.53mm i.d. Column 1538<br />
0.32mm i.d. Column 1567<br />
0.25mm i.d. Column 1569<br />
Replacement Liner for:<br />
0.53mm i.d. Column, 2/pk 1539<br />
0.32mm i.d. Column, 2/pk 1571<br />
0.25mm i.d. Column, 2/pk 1573<br />
Counter-bored Nut, 2/pk 1549<br />
Replacement Ferrule, 2/pk 1558<br />
Contact your Alltech office or distributor for current or local prices.<br />
1579<br />
443