GC Accessories
GC Accessories
GC Accessories
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Gas Flow<br />
A C C E S S O R I E S<br />
Flowmeters<br />
Alltech Digital Flow Check Mass Flowmeters<br />
NIST traceable calibration for seven gases<br />
• Measure Air, Helium, Hydrogen, Nitrogen, Oxygen, 5% Argon/Methane and<br />
Carbon Dioxide<br />
• Water vapor will not affect readings—suitable for purge and trap applications<br />
• +/-2% of reading accuracy insures your flow rates are on target<br />
• DFC-HR high resolution model is ideal for low-flow applications<br />
Alltech’s model DFC and DFC-HR Digital Flow Check flowmeters feature<br />
unsurpassed versatility. Both models come standard with NIST traceable calibration<br />
for seven gases making them suitable for <strong>GC</strong> applications such as monitoring<br />
detector gases, packed column flow rates and determining split ratios. Flowmeters<br />
can be used in SFC, SFE, and industrial hygiene applications as well as in the<br />
general lab. Install flowmeters in-line for continuous flow monitoring to traps,<br />
6249<br />
sorbent tubes, incubators, fermentors or reaction vessels without interrupting gas<br />
flow. Use flowmeters with either a positive or negative (vacuum) flow source.<br />
The DFC and DFC-HR mass flowmeters incorporate a rugged solid-state sensor with microprocessor control that<br />
measures true mass flow eliminating the ambient temperature and pressure change errors associated with other types<br />
of flowmeters. Water vapor errors have also been eliminated. Flow measurements will be precise and accurate to<br />
within +/-2% of your reading. Gas flow travels straight through the meter reducing backpressure, internal volume<br />
and sensor purge time allowing for readings to stabilize quickly. Easily change between mass flow, linear velocity and<br />
split ratio modes.<br />
Both Digital Flow Check meters are shipped with an NIST traceable multi-point certificate of calibration<br />
that includes percent error data. Meters are calibrated for seven gases using NIST traceable standards. Periodic<br />
recalibration is recommended to maintain accuracy and compliance with ISO, GLP, GMP and other quality standards.<br />
Model DFC Standard Mass Flowmeter has a measurement range of 0.1 to 300 SCCM for CO2 and 0.1 to 500 SCCM<br />
for the remaining gases. It is lightweight, portable and easy to use. Display resolution of 0.1 SCCM makes it ideal<br />
for most applications.<br />
Model DFC-HR High Resolution Mass Flowmeter features a display resolution of 0.01 SCCM when measuring<br />
below 10 SCCM providing a higher degree of precision required for low-flow applications such as setting capillary <strong>GC</strong><br />
flow or leak testing. Measurement range is 0.01 to 300 SCCM for CO2 and 0.1 to 500 SCCM for the remaining gases.<br />
Use the autozero function to quickly zero the meter for current ambient conditions.<br />
What’s included: Both models include 1 ft of 1/32" (0.8mm) i.d. silicone tubing, 1 ft of 1/8" (3.8mm) i.d.<br />
silicone tubing, 2 barbed inlet/outlet fittings for each tubing size, a general purpose adapter to connect to Agilent<br />
FID, splint vent traps, packed <strong>GC</strong> columns and gas lines, split vent adapter for connection to Agilent <strong>GC</strong> split vents,<br />
and 9V battery. Model DFC-HR also includes a capillary column adapter. Replacement accessories on facing page.<br />
394<br />
© Copyright 2004 Alltech Associates, Inc.<br />
Suggested Flowmeter Applications<br />
Low Flow Applications (DFC-HR )<br />
• Capillary <strong>GC</strong> Flows<br />
• Split Ratios<br />
• Leak Testing<br />
• Applications Requiring Precise Flow<br />
Measurement Below 10cc/min<br />
<strong>GC</strong> Applications (DFC and DFC-HR )<br />
• Detector Gases<br />
• Packed Column Flow<br />
• Split Ratios<br />
• Linear Velocity<br />
Lab Applications (DFC and DFC-HR )<br />
• Set Instrument Operating Parameters<br />
• Industrial Hygiene Applications<br />
• Monitor Flow to Traps, Sorbent Tubes,<br />
Incubators, Fermentors & Reaction Vessels<br />
• SFC and SFE Applications<br />
• In-Line Applications<br />
• Monitor Vacuum & Purging Processes<br />
• Gas Blending<br />
• Gas Sampling<br />
Contact your Alltech office or distributor for current or local prices.