13.04.2015 Views

Grace Catalog 2008

Grace Catalog 2008

Grace Catalog 2008

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Grace</strong> <strong>Catalog</strong> <strong>2008</strong>


여백입니다.


여백입니다.


HPLC | IC<br />

HPLC Instruments . . . . . . . . . . . . . . . . 5–23<br />

Detectors 5–11, 14<br />

ELSD 5–11<br />

UV 14<br />

Nitrogen Gas Generators 12–13<br />

for ELSD 12<br />

for LC/MS 13<br />

Autosamplers 15<br />

Column Heaters 16–17<br />

Pumps 18–21<br />

Data Collection & Software 22–23<br />

HPLC Columns . . . . . . . . . . . . . . . . . .24–97<br />

Introduction 24–33<br />

Small Molecule 34–80, 82–83<br />

<strong>Grace</strong> ® VisionHT 34–37<br />

<strong>Grace</strong> ® <strong>Grace</strong>Smart 50–51<br />

<strong>Grace</strong> ® <strong>Grace</strong>Alpha 52<br />

Alltech ® Alltima HP 38–43<br />

Alltech ® Prevail 44–47<br />

Alltech ® Platinum 48–49<br />

Alltech ® Brava 53<br />

Alltech ® Alltima 54–56<br />

Alltech ® Apollo 57<br />

Alltech ® Econosphere 57<br />

Alltech ® Adsorbosphere 58–59<br />

Alltech ® Allsphere 59<br />

Alltech ® Specialty Small Molecule 67–68<br />

OPA Amino Acid, Catecholamine, Nucleotide-Nucleoside,<br />

Mixed-Mode, Carbohydrate Cation<br />

Grom Sil 60–61<br />

Grom Sapphire 62<br />

Grom Amino Acid Kits 63<br />

Jones Genesis ® 64–65<br />

Jones Apex 66<br />

Vydac ® Venture ® 69<br />

Vydac ® Denali ® 69<br />

Vydac ® 201TP and 202TP C18 70–71<br />

Distributed Small Molecule Columns 72–83<br />

Astec , Brownlee , Jordi , LiChrosorb ® , LiCrospher ® , Nucleosil ® ,<br />

Partisil , Partisphere ® , Polymer Labs, Shodex ® , Spherisorb ® ,<br />

Ultrasphere ® , ZirChrom ®<br />

Large Molecule 84–97<br />

Vydac ® MS 85–87<br />

Vydac ® Everest ® . . . . . . . . . . . . . . . . . . . . . . 88–89<br />

Vydac ® TP 90–92<br />

Vydac ® ProZap C18 93–94<br />

Vydac ® Venture ® A 95<br />

Alltech ® ProSphere 96–97<br />

Alltech ® Macrosphere 97<br />

Distributed Large Molecule Columns 74–75, 79–81<br />

Brownlee , Jordi , Polymer Labs, Shodex ® ,<br />

IC Columns . . . . . . . . . . . . . . . . . . . 98–105<br />

Custom HPLC Columns . . . . . . . . . . . . . . 106<br />

Empty HPLC Hardware, Frits. . . . . . . . . 107–110<br />

HPLC Accessories . . . . . . . . . . . . . . 111–146<br />

Prefilters 111<br />

Fittings 112–122<br />

Mobile Phase Handling 123–131<br />

Pump Accessories 132–135<br />

Valves 136–146


analytical hplc<br />

Evaporative Light Scattering Detectors<br />

Leading the Way in ELSD Technology for More Than 20 Years<br />

Alltech has more than 20 years of experience engineering and manufacturing Evaporative Light Scattering Detectors. Our global<br />

network of dedicated application chemists and technical support professionals provides you with the comprehensive service and<br />

support you need.<br />

How Does It Work?<br />

hplc instruments<br />

ELSDs detect any compound less volatile than the mobile phase using a simple three-step process:<br />

1. Nebulization<br />

7049<br />

2. Evaporation<br />

7048<br />

3. Detection<br />

7047<br />

Column effluent passes<br />

through a needle and mixes<br />

with nitrogen gas to form a<br />

dispersion of droplets.<br />

Droplets pass through a heated<br />

“drift tube” where the mobile<br />

phase evaporates, leaving a fine<br />

mist of dried sample particles in<br />

solvent vapor.<br />

The sample particles pass<br />

through a cell and scatter light<br />

from a laser beam. The scattered<br />

light is detected, generating<br />

a signal.<br />

Are There Any Limitations?<br />

1. The mobile phase must be volatile.<br />

2. The sample must be less volatile than the mobile phase.<br />

ELSD Advantages Over Other LC Detectors<br />

ELSD RI UV MS<br />

CHART KEY<br />

Sensitivity<br />

Gradient Capability<br />

Baseline Stability<br />

Solvent Interference<br />

Mass Balance<br />

Excellent:<br />

Good:<br />

Poor:<br />

more info<br />

For more information about Evaporative Light Scattering<br />

Detection, including applications, literature, and an informational<br />

movie, visit www.elsd.com.<br />

www.discoverysciences.com


analytical hplc<br />

hplc instruments<br />

ELSD Advantages Over Other LC Detectors<br />

ELSD improves baseline stability and detection sensitivity<br />

compared to refractive index (RI).<br />

Solvent<br />

Front<br />

Sugar Alcohols<br />

1<br />

1<br />

2<br />

3<br />

2 3<br />

ELSD<br />

RI<br />

10627<br />

10635<br />

1. Xylitol (200ppm)<br />

2. Sorbitol (200ppm)<br />

3. Dulcitol (200ppm)<br />

ELSD shows what may be missing from your UV<br />

chromatogram.<br />

Plant Oil Extract<br />

0 10 20 30 40 50 60<br />

ELSD<br />

10656<br />

10657<br />

UV at 254nm<br />

70 Min.<br />

0 2 4 6 8 10 12 14 16<br />

18 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm,<br />

4.6 x 250mm (Part No. 35101)<br />

Mobile Phase: Acetonitrile:Water (79:21)<br />

Flow Rate: 1.0mL/min<br />

Column Temp: 30°C<br />

Column: Alltech ® Alltima C18, 3μm, 2.1 x 150mm<br />

(Part No. 43852)<br />

Mobile Phase: A: 0.1% Formic Acid B: Methanol<br />

Gradient: Time: 0 40<br />

%B: 60 100<br />

Flow Rate: 0.25mL/min<br />

Column Temp: 30°C<br />

Use ELSD in parallel with UV/Vis and MS for maximum<br />

structural and concentration information.<br />

1<br />

Steroid Hormone Formulation<br />

1. Povidone (8 µg)<br />

2. Chlormadinone Acetate (1.5 µg)<br />

3. Mestranol (3 µg)<br />

2<br />

2<br />

3<br />

2<br />

ELSD<br />

1<br />

3<br />

MS<br />

1<br />

3<br />

UV at 254nm<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

10639<br />

10641<br />

10640<br />

Column: Vydac ® Denali ® 238DE C18, 3µm, 2.1 x 50mm<br />

(Part No. 238DE3205)<br />

Mobile Phase: 0.2% Formic Acid in Acetonitrile:Water (55:45)<br />

Flow Rate: 0.2mL/min<br />

Column Temp: Ambient<br />

ELSD obtains a more accurate representation of sample<br />

mass than UV/Vis.<br />

1. Mephobarbital (500ppm)<br />

2. Secobarbital (500ppm)<br />

1:1 Mixture<br />

UV at 230nm<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

1<br />

2<br />

1<br />

2<br />

ELSD<br />

10616<br />

10617<br />

Column: Alltech ® Alltima HP C18 HL, 5µm, 4.6 x 250mm<br />

(Part No. 87698)<br />

Mobile Phase: Acetonitrile:Water (30:70)<br />

Flow Rate: 1.0mL/min<br />

Column Temp: 45°C<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® 3300 ELSD<br />

High Sensitivity and Ease of Use<br />

Detection of non-volatile compounds has never been easier<br />

than with our new, most sensitive ELSD.<br />

Sensitive<br />

• Low noise and excellent baseline stability<br />

• Low nanogram detection limits<br />

Simple<br />

• Step-by-step method wizard automates detector setup<br />

• Easy access to parts requiring cleaning or maintenance<br />

Small<br />

• Small footprint minimizes bench space requirements<br />

11.6" H x 10.3" W x 19.5" D (29.5cm H x 26.2cm W x 49.5cm D)<br />

hplc instruments<br />

6947b<br />

A Windows ® -based<br />

user interface makes<br />

navigating through<br />

menus intuitive and<br />

easy. Drivers for Agilent<br />

ChemStation and<br />

EZChrom Elite/EZStart<br />

are available.<br />

6967<br />

Alltech ® 3300 ELSD*<br />

Description<br />

Part No.<br />

3300 ELSD 110V–240V 5135834<br />

*Patent pending.<br />

Service and Support<br />

Our dedicated technical support professionals provide you<br />

with the comprehensive support you need. Our complete line<br />

of service products, including qualification, installation, training,<br />

repair service, and preventive maintenance, lets you choose<br />

what best meets your needs and budget requirements.<br />

Services for the Alltech ® 3300 ELSD<br />

Description<br />

Installation and Training<br />

Qualification<br />

IQ/OQ at Customer Site<br />

PQ at Customer Site<br />

IQ/OQ/PQ at Customer Site<br />

Part No.<br />

INSTALL<br />

Q330010<br />

Q330020<br />

Q330030<br />

Alltech ® ELSDs are designed and manufactured in<br />

accordance with the following standards: EN6101-1 + A2:95,<br />

EN555011: 1998, FCC CFR 47 Part 15: 2001,<br />

EN 61326: 1998, EN 6100-3-2: 1995 + A14:2000 and<br />

EN61000-3-3: 1995<br />

3300 ELSD Specifications<br />

Light Source:<br />

Detector Element:<br />

Temperature Range:<br />

Nebulizer Gas:<br />

Inlet Pressure:<br />

Typical Operating Range:<br />

Flow Control:<br />

Mobile Phase Flow Rate:<br />

Analog Output:<br />

Communications:<br />

User Interface:<br />

Power Requirements:<br />

Dimensions:<br />

Weight:<br />

IEC/FDA Classification:<br />

Manufacturing Standards:<br />

Warranty:<br />

Control:<br />

Laser diode with collimating optics, 650nm,<br />

30mW output, class IIIB<br />

Silicon photodiode<br />

Ambient to 120ºC in 1ºC increments<br />

Nitrogen preferred; Calibrated to 4.0L/min<br />

60–80psig<br />

1.0–2.0L/min<br />

Digital Mass Flow Control<br />

To 3.0mL/min<br />

1V or 10mV full scale<br />

Inputs: TTL/contact closure for auto zero,<br />

gas shutoff, start, and standby<br />

Outputs: Contact Closure for pump<br />

shutdown in error conditions, general events<br />

Data Ports: USB, RS232, Ethernet<br />

Full-color Microsoft Windows ® -based<br />

Graphical LCD with alphanumeric keypad<br />

120/240V, 50/60Hz<br />

11.6" H x 10.3" W x 19.5" D<br />

(29.5cm H x 26.2cm W x 49.5cm D)<br />

30lb (16kg)<br />

Class 1 Laser Product; Complies with<br />

21 CFR Subpart J<br />

Meets all applicable safety and EMC<br />

certifications; CE, UL, and CSA certified<br />

1 year parts and labor<br />

Drivers for Agilent Chemstation and<br />

EZChrom Elite/EZ Start<br />

www.discoverysciences.com


analytical hplc<br />

hplc instruments<br />

ELSD Sensitivity and Reproducibility<br />

With reduced noise and greater baseline stability, the 3300 ELSD is more sensitive than any other ELSD available.<br />

2<br />

2<br />

1<br />

2<br />

3<br />

3<br />

2<br />

3<br />

3<br />

3<br />

Competitor A<br />

Competitor B<br />

Competitor C<br />

1. Methyl Paraben (200ng)<br />

2. Propyl Paraben (200ng)<br />

3. Butyl Paraben (200ng)<br />

Model<br />

Butyl Paraben<br />

Limit of Detection (LOD)<br />

3300 ELSD 25ng<br />

Competitor A 200ng<br />

Competitor B 200ng<br />

Competitor C 150ng<br />

Competitor D 50ng<br />

Competitor D<br />

1<br />

3300 ELSD<br />

0 1 2 3 4 5 6 7 8 Min.<br />

Column: Alltech ® Alltima C18, 5µm, 4.6 x 250mm<br />

(Part No. 88056)<br />

Mobile Phase: Water:Acetonitrile (40:60)<br />

Flow Rate: 1.0mL/min<br />

Column Temp: Ambient<br />

The 3300 ELSD’s near ambient temperature evaporation<br />

maximizes sensitivity for semi-volatiles.<br />

The 3300 ELSD is very reproducible as demonstrated by<br />

10 identical injections of four ginkgolide components.<br />

1<br />

1<br />

1. Ibuprofen (100ppm)<br />

Component % RSD<br />

1. Bilobalide 1.7<br />

2. Ginkgolide C 1.3<br />

3. Ginkgolide A 1.6<br />

4. Ginkgolide B 1.0<br />

1<br />

1<br />

2<br />

1<br />

30°C<br />

3<br />

4<br />

32.5°C<br />

1<br />

35°C<br />

37.5°C<br />

1<br />

40°C<br />

42.5°C<br />

0 1<br />

2 3 Min.<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column: Alltech ® Alltima HP C18, 3µm, 2.1 x 100mm<br />

(Part No. 87669)<br />

Mobile Phase: Acetonitrile: 0.1%TFA in Water (80:20)<br />

Flow Rate: 0.3mL/min<br />

Column Temp: Ambient<br />

Column: Alltech ® Platinum C18, 5µm, 4.6 x 250mm<br />

(Part No. 32064)<br />

Mobile Phase: Water:Methanol:THF (65:25:10)<br />

Flow Rate: 1.0mL/min<br />

Column Temp: Ambient<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

<br />

www.discoverysciences.com


analytical hplc<br />

ELSD Performance Benefits<br />

Stable Baselines with Fast, Steep Gradients<br />

1<br />

0 1 2 3 Min.<br />

2<br />

3<br />

10658<br />

1. Acetylsalicylic Acid<br />

2. Diphenhydramine<br />

3. Trimipramine<br />

Use ELSD to Trigger Collection of UV<br />

Transparent Compounds in Prep Applications<br />

10679<br />

1. LLLn<br />

2 3<br />

2. LLL<br />

3. LLO<br />

4. PLL<br />

4 5. LOO<br />

5 6. PLO<br />

6 7. PLP<br />

7,8 8. OOO<br />

1<br />

9,10<br />

9. SLO<br />

10. POO<br />

0 5 10 15 20 Min.<br />

hplc instruments<br />

Column: Alltech ® Alltima HP C18, 3µm,<br />

7 x 33mm Rocket (Part No. 87671)<br />

Mobile Phase: A: 0.1% TFA in Water B: 0.1% TFA in Acetonitrile<br />

Gradient: Time: 0 3<br />

%B: 10 90<br />

Flow Rate: 2.5mL/min<br />

Column Temp: 30°C<br />

Simplify Detection of Weak Absorbing Polymers<br />

Column: Vydac ® Denali ® 238DE C18, 10µm, 22 x 150mm<br />

(Part No. 238DE102215)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 10 20 21<br />

%B: 45 50 70 45<br />

Flow Rate: 10mL/min<br />

Column Temp: 25°C<br />

Easily Detect Non-Chromophoric Drug Compounds<br />

1<br />

10636<br />

10680<br />

1. mPEG-SBA<br />

1<br />

1. Spectinomycin<br />

0 3 6 9 12 15 Min.<br />

Column: Alltech ® ProSphere 300, 5µm, 4.6 x 150mm<br />

(Part No. 35560)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 3 15<br />

%B: 30 30 80<br />

Flow Rate: 1.0mL/min<br />

Column Temp: Ambient<br />

0 1<br />

2 3 4 5 6 7 8 9 Min.<br />

Column: Alltech ® Alltima HP C18 Amide, 3µm, 4.6 x 50mm<br />

(Part No. 87829)<br />

Mobile Phase: 10mM Ammonium Carbonate:Acetonitrile (98:2)<br />

Flow Rate: 1.0mL/min<br />

Column Temp: Ambient<br />

Use ELSD to Simplify Triglyceride Analysis<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

0<br />

0 5 10<br />

1<br />

Sesame Seed Oil<br />

2<br />

3<br />

4<br />

5 7 8 9<br />

6<br />

10<br />

15 20 25 30 35 Min.<br />

1. LLL<br />

2. LLO<br />

3. LLP<br />

4. OOL<br />

5. POL<br />

6. PPL<br />

7. OOO<br />

8. OOP<br />

9. PPO<br />

10. OOS<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 5µm,<br />

4.6 x 250mm (Part No. 87698)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 1.0mL/min<br />

Column Temp: 20°C<br />

10581<br />

5 6<br />

Improve Sensitivity for Carbohydrates<br />

Robitussin ® Flu Syrup<br />

10557<br />

1. Sucralose<br />

2 4<br />

2. Fructose<br />

3. Sorbitol<br />

4. Glucose<br />

5. Sucrose<br />

3<br />

6. Maltose<br />

1<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm,<br />

4.6 x 250mm (Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 15 15 25 25 50<br />

Flow Rate: 1.0mL/min<br />

Column Temp: Ambient<br />

www.discoverysciences.com


analytical hplc<br />

ELSD Performance Benefits<br />

hplc instruments<br />

Use ELSD for Triggering Fraction Collection of UV/Vis<br />

Transparent Compounds in Preparative Applications<br />

1<br />

10438<br />

1. Ethinamate (5.0 mg/mL)<br />

Improve Sensitivity for Carbohydrates<br />

Carbohydrates–10ng on Column<br />

2<br />

1 3<br />

1. Fructose<br />

2. Sucrose<br />

3. Raffinose<br />

10498<br />

0<br />

UV<br />

ELSD<br />

1 2 3 4 5 6 7 Min.<br />

Column: Alltech ® Alltima C18, 5µm, 10 x 150mm<br />

(Part No. 81102)<br />

Mobile Phase: Water:Acetonitrile (55:45)<br />

Flow Rate: 5.0mL/min<br />

Column Temp: 25°C<br />

0 1 2 3 4 5 6 7 8 9 10 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 4.6 x 150mm<br />

(Part No. 35102)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 10 11 14<br />

%B: 80 50 80 80<br />

Flow Rate: 1.0mL/min<br />

Column Temp: Ambient<br />

Simplify Detection of Difficult Samples<br />

PEG 600<br />

10276<br />

Detect Difficult Samples without Derivatizing<br />

Biodiesel Derived from Soy Bean Oil<br />

10644<br />

1. Mono-acylglycerol (MAG)<br />

2. MAG<br />

3. MAG<br />

4. Fatty Acid Methyl Ester (FAME)<br />

5. MAG<br />

6. FAME<br />

7. FAME<br />

8. MAG<br />

9. FAME<br />

10. Di-acylglycerol (DAG)<br />

11. Tri-acylglycerol (TAG)<br />

4 6<br />

7<br />

9<br />

8<br />

3 5<br />

12 10<br />

11<br />

0 3 6 9 12 15 Min.<br />

Column: Alltech ® Adsorbosphere C8, 5µm, 4.6 x 150mm<br />

(Part No. 287122)<br />

Mobile Phase: A: Water B: Methanol<br />

Gradient: Time: 0 15<br />

%B: 30 60<br />

Flow Rate: 1.0mL/min<br />

0 5 10 15 20 25 30 Min.<br />

Column: Alltech ® Alltima HP C18 HiLoad,<br />

5µm, 4.6 x 250mm (Part No. 87698)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 5 30 32 35<br />

%B: 0 15 70 70 0<br />

Flow Rate: 1.0mL/min<br />

10<br />

www.discoverysciences.com<br />

more info<br />

Interested in ELSD for biodiesel process monitoring? We<br />

have a complete solution including equipment, columns, and<br />

accessories. Request sheet M181 or call or visit our website for<br />

more information.


analytical hplc<br />

Alltech ® ELSD 800<br />

The Benefits of ELSD for<br />

the Price of a UV/VIS or<br />

RI Detector<br />

Low Cost, High Performance<br />

The ELSD 800 is an economical alternative to<br />

full-featured ELSDs. Now everyone can afford to add<br />

universal HPLC detection to any HPLC system to replace<br />

or complement existing detectors.<br />

Easy to Use<br />

The ELSD 800 is easy to operate and requires virtually no<br />

optimization. The same low temperature and gas flow is used<br />

for most applications, including organic and aqueous mobile<br />

phases, and gradient methods.<br />

Small and Stackable<br />

ELSD 800 Specifications<br />

Light Source:<br />

Laser diode with collimating optics, 670nm,<br />

max output less than 5mW, class IIIA<br />

Detector Element: Silicon photodiode<br />

Temperature Range: Ambient to 110°C in 1°C increments<br />

Nebulizer Gas:<br />

Up to 3.0L/min, nitrogen recommended<br />

Inlet Pressure:<br />

15–90psig (1.0–6.0 Bar)<br />

Typical Operating Range: 1.0–3.0L/min<br />

Flow Control:<br />

Fixed orifice with regulated pressure<br />

Mobile Phase Flow Rate: To 5.0mL/min<br />

Analog Output:<br />

1V or 10mV full scale<br />

Communications: Outputs: Contact closure for pump shutdown<br />

in error conditions<br />

User Interface:<br />

Liquid crystal display and keypad entry of<br />

operating parameters<br />

Power Requirements: 120/240V, 50/60Hz<br />

Dimensions:<br />

14.0" H x 13.0" W x 18.0" D<br />

(35.6cm H x 33.1cm W x 45.7cm D)<br />

Weight:<br />

20lb (9kg)<br />

Warranty:<br />

1 year parts and labor<br />

*Patent Pending.<br />

Alltech ® ELSD 800<br />

Description<br />

Part No.<br />

ELSD 800<br />

120V 800100<br />

240V 800200<br />

6419KO<br />

The ELSD 800 is small and stackable, minimizing bench space<br />

needed, especially when using multiple ELSDs in close proximity.<br />

ELSD Qualification<br />

and Service<br />

Service and Support<br />

Our dedicated technical support professionals provide you<br />

with the comprehensive support you need. Our complete line<br />

of service products, including qualification, installation, training,<br />

repair service, and preventive maintenance, lets you choose<br />

what best meets your needs and budget requirements.<br />

Qualification (IQ/OQ/PQ)<br />

<strong>Grace</strong> makes it easy for you to integrate the ELSD into<br />

a qualified HPLC system. Detailed IQ/OQ/PQ procedures are<br />

included with the 3300 ELSD to help you perform your own<br />

qualification. We also provide the option of on-site qualification.<br />

Qualification Services<br />

Description<br />

3300 ELSD<br />

IQ/OQ at customer site<br />

PQ at customer site<br />

IQ/OQ/PQ at customer site<br />

Re-OQ performed on site<br />

Re-OQ/PQ performed on site<br />

800 ELSD<br />

IQ/OQ performed on site<br />

PQ performed on site<br />

IQ/OQ/PQ performed on site<br />

Re-OQ performed on site<br />

Re-OQ/PQ performed on site<br />

2000ES ELSD<br />

Re-OQ performed on site<br />

Re-OQ/PQ performed on site<br />

2000 ELSD<br />

Re-OQ performed on site<br />

Re-OQ/PQ performed on site<br />

Preventive Maintenance and Repair<br />

Part No.<br />

Q330010<br />

Q330020<br />

Q330030<br />

Q330040<br />

Q330050<br />

Q80010<br />

Q80020<br />

Q80030<br />

Q80040<br />

Q80050<br />

Q60040ES<br />

Q60050ES<br />

Q60040<br />

Q60050<br />

<strong>Grace</strong> offers many flexible options for maintenance and<br />

repair of your ELSD. These services can be performed at<br />

your site or at our facility. Service contracts are available. An<br />

annual cleaning and calibration is recommended. Extended<br />

warranties can be purchased to provide peace of mind and/or<br />

extend the warranty on refurbished instruments.<br />

Preventive Maintenance<br />

Description<br />

Part No.<br />

Preventive Maintenance Visit – Includes replacement of 600365<br />

nebulizer, light trap, o-rings, and apertures<br />

Cleaning and NIST Calibration at <strong>Grace</strong><br />

500 ELSD 500361<br />

800 ELSD 800361<br />

2000/2000ES ELSD 600361<br />

3300 ELSD 3300361<br />

Cleaning and NIST Calibration at Customer Site<br />

500 ELSD 500363<br />

800 ELSD 800363<br />

2000/2000ES ELSD 600363<br />

3300 ELSD 3300363<br />

ELSD Service Agreement – 1-year repair, parts, and labor at<br />

<strong>Grace</strong> repair center, includes annual clean + NIST calibration<br />

800, 2000/2000ES 600370<br />

3300 3300370<br />

hplc instruments<br />

www.discoverysciences.com 11


analytical hplc<br />

hplc instruments<br />

ELSD Nitrogen Generator<br />

• Simplifies ELSD operation<br />

• Produces a continuous supply of high purity nitrogen<br />

from compressed air<br />

• Replaces inconvenient nitrogen cylinders<br />

• Requires no electricity<br />

Water vapor and oxygen permeate through the wall of the<br />

membrane quickly. Only nitrogen flows through the fiber bores<br />

to the ELSD.<br />

The ELSD Nitrogen Generator has a small, compact footprint that<br />

fits easily on the lab bench next to your ELSD or mounts on the<br />

wall nearby.<br />

Increase productivity, reduce operating costs, and improve<br />

lab safety by eliminating nitrogen cylinders. Forget about the<br />

need to change the nitrogen cylinder or wondering whether<br />

there is enough nitrogen left to finish the run.<br />

The ELSD Nitrogen Generator requires no electricity and has<br />

no moving parts. Nitrogen is generated using a proprietary<br />

membrane separation technology. Simply connect the<br />

generator to your lab’s existing compressed air supply or<br />

suitable air compressor. The generator separates air into its<br />

component gases and only nitrogen flows through to the ELSD.<br />

The ELSD Nitrogen Generator produces a continuous, on<br />

demand supply of pure nitrogen at flow rates up to 4L/min.<br />

Two ELSDs may be used with one generator as long as your<br />

total gas flow rate is less than 4L/min.<br />

more info<br />

For information on air compressors, see page 211.<br />

6053<br />

Nitrogen Generator Specifications<br />

Nitrogen Purity: 99%<br />

Nitrogen Flow:<br />

4L/min<br />

Suspended Liquids: None<br />

Particles:<br />


analytical hplc<br />

LC/MS Nitrogen Generators<br />

High Purity Nitrogen from Parker and Domnick Hunter<br />

• Choose from membrane and PSA technologies<br />

• Stand-alone units or models with built-in compressor<br />

• Wide range of flows to meet your needs<br />

LC/MS instrumentation uses nitrogen as purge gas in its nebulizer, and has special nitrogen purity requirements. Parker Balston ®<br />

nitrogen generators use membrane technology, while Domnick Hunter uses PSA (pressure swing adsorption). Membrane units<br />

generally offer quieter operation, while PSA units require lower air flows.<br />

Nitrogen generators used for LC/MS are either fixed or variable purity units. Variable purity units have different nitrogen purities<br />

that are dependent on the inlet pressure, outlet pressure, and flow. Many of the variable purity units have available built-in oxygen<br />

analyzers to monitor the purity of the gas being provided.<br />

hplc instruments<br />

7301<br />

7302<br />

7261<br />

Parker Balston ® NitroFlow Lab<br />

Parker Balston ® N2 Series<br />

Domnick Hunter ® LC/MS30<br />

Parker Balston<br />

Domnick Hunter<br />

Model NitroFlow Lab N2-14 N2-22 N2-35 N2-45 LCMS30-1 LCMS30-0<br />

Flow (L/min) 30 14 22 35 45 30 30<br />

Air In (L/min) Built-in Compressor 73 113 171 225 Built-in Compressor 130<br />

Inlet Pressure (PSIG) N/A 60 60 60 60 N/A 130.5<br />

Outlet Pressure (PSIG) 100 145 145 145 145 102 102<br />

Nitrogen Purity Up to 99.5% 99% 99% 99% 99% 98% 99%<br />

Method Membrane Membrane Membrane Membrane Membrane PSA PSA<br />

Dimensions (H x W x D) 31" x 18" x 32" 51.5" x 18" x 16.2"<br />

67" x 24" x 20"<br />

20" x 28" x 32.5" 20" x 28" x 30"<br />

76cm x 46cm x 81cm 130.8cm x 45.7cm x 41.1cm 140cm x 61cm x 50cm 51cm x 70.5cm x 82.6cm 51cm x 70.5cm x 76cm<br />

Weight 285lb (130kg) 75lb (34kg) 250lb (114kg) 284lb (129kg) 298lb (135kg)<br />

110V Part Numbers<br />

without O2 analyzer 80552 80163 80293 8618464 80308 8618461 8618463<br />

with O2 analyzer — 80165 80297 8618466 80311 — —<br />

220V Part Numbers<br />

without O2 analyzer 80593 80169 80295 8618465 80309 8618462 8618460<br />

with O2 analyzer — 80171 80302 8618467 80312 — —<br />

www.discoverysciences.com 13


analytical hplc<br />

hplc instruments<br />

UV Detectors<br />

Thermo UV1000 Single<br />

Wavelength UV Detector<br />

• Unique optical design reduces noise<br />

• Programmable wavelength changes<br />

• Flexibility with interchangeable flow cells<br />

• Comes with analytical flow cell and<br />

deuterium lamp<br />

The unique dual-beam, forward optical design<br />

of the Thermo UV Detector reduces noise and<br />

drift by focusing the light beam away from the flow call walls.<br />

Reference and sample beams are monitored at the same<br />

length for a wide, linear dynamic range.<br />

7424<br />

Thermo UV2000 Dual Wavelength UV Detector<br />

• Collects up to 20 spectra per run in stand alone mode<br />

• Dual wavelength operation for measuring absorbance<br />

ratios<br />

• Automatic lamp shut-down extends lamp life<br />

• Comes with analytical flow cell and tungsten and<br />

deuterium lamps<br />

Thermo’s UV2000 provides an excellent signal-to-noise<br />

ratio for research or routine analysis. Program different<br />

wavelengths to improve sensitivity or selectivity of different<br />

compounds.<br />

UV1000 Single Wavelength UV Detector Specifications<br />

Wavelength Range:<br />

190–380nm; 190–800nm with<br />

optional tungsten lamp<br />

Wavelength Accuracy:<br />

±1.0nm<br />

Wavelength Precision:<br />

±1.0nm<br />

Spectral Bandwidth:<br />

6nm<br />

Noise:<br />


analytical hplc<br />

Autosamplers<br />

Alltech ® 570 Autosampler<br />

• Affordably<br />

automate HPLC<br />

and IC analysis<br />

• Flushed loop<br />

filling maximizes<br />

precision and<br />

reproducibility<br />

• Partial loop filling<br />

minimizes sample<br />

waste<br />

Choose between flushed and partial<br />

loop filling and stainless steel and PEEK<br />

fluid paths.<br />

1408<br />

Alltech ® 580 Autosampler<br />

• Automates sample<br />

prep tasks: sample<br />

dilution, derivatization,<br />

and internal standard<br />

addition<br />

• Capable of three<br />

different injection<br />

techniques<br />

• Large injection volume<br />

range for maximum<br />

versatility<br />

• Built-in column heater<br />

Multifunctional autosampler<br />

improves laboratory efficiency.<br />

3000<br />

hplc instruments<br />

570 Autosampler Specifications<br />

Vial Capacity: 96 samples (92 with needle wash), 48 (5mL)<br />

vials (optional)<br />

Injection Volume: Flushed Loop: 5–500µL (dispenser controlled),<br />

5–5000µL (by head space pressure).<br />

Partial Loopfill: 10–490µL in steps of 10µL<br />

(depending on the loop volume, maximum 50%<br />

of the loop volume)<br />

Injections per Vial: 9 Maximum<br />

Needle Wash: Selectable, 50µL fixed volume between vials<br />

Reproducibility: Flushed Loop Injections: RSD≤0.5%<br />

Partial Loop Injections: RSD≤1.0%<br />

Power:<br />

115 VAC/230 VAC; 50/60 Hz<br />

Dimensions:<br />

11.1" H x 11.8" W x 17.3" D<br />

(28cm H x 30cm W x 44cm D)<br />

Weight:<br />

34lb (15.5kg)<br />

Warranty:<br />

1 year<br />

Model 570 Autosampler<br />

Description<br />

Part No.<br />

Flushed Loop Filling<br />

Stainless Steel 575100<br />

PEEK 575500<br />

Partial Loop Filling<br />

Stainless Steel 570150<br />

PEEK 570550<br />

Spare Parts for 570 Autosampler<br />

Description<br />

Part No.<br />

Pump Tubing Cassette 575115<br />

Side-Port Sample Needle, 3/pk 575130<br />

Large Volume Option, Field Installable 575165<br />

Air Needle 575125<br />

Sample Drain for Headspace Pressure 575170<br />

Auxilliary and Control I/O Cable 570101<br />

Tubing from Needle to Valve, 10ft 20064<br />

Needle Connection Nut 575175<br />

Needle Connection Ferrule, 10/pk 575185<br />

Standard Vial Tray 575110<br />

580 Autosampler Specifications<br />

Vial Capacity: 84 (1.5mL) vials + 3 (10mL) vials,<br />

96 (1.5mL) vials (optional),<br />

24 (10mL) vials (optional)<br />

Injection Volume: 1–5000µL in 1µL increments,<br />

5000–7500µL in 1.5µL increments,<br />

7500–10,000µL in 4µL increments<br />

Injections per Vial: 9 maximum<br />

Analysis Time: 9hrs 59min 59sec maximum<br />

Reproducibility: Full Loop Injections: ≤0.3% RSD,<br />

Partial Loop Injections: ≤0.5% RSD,<br />

µL Pick-Up Injections(>10µL):≤1.0%<br />

Carry Over:<br />


analytical hplc<br />

Column Heaters<br />

<strong>Grace</strong> ® and Jetstream Models<br />

hplc instruments<br />

<strong>Grace</strong> ® 7971R<br />

<strong>Grace</strong> ® 7990R w/Controller<br />

<strong>Grace</strong> ® 7956R w/Controller<br />

Jetstream Plus 2<br />

7254<br />

7255 7256 4298<br />

Specifications<br />

• Rugged, reliable,<br />

easy-to-use<br />

• Precise temperature<br />

control above ambient<br />

• Temperature cut-out<br />

with RS232 interface<br />

• Block heater with LED<br />

interface<br />

• Controls one or two<br />

columns<br />

• Independent<br />

temperatures<br />

• Single and dual output<br />

controllers<br />

• Long column oven<br />

• RS232 interface<br />

• Stabilizes column<br />

temperatures<br />

• Temperatures range:<br />

0 to 95°C<br />

• Ideal for GLP and<br />

FDA-regulated analyses<br />

• Heater/Chiller with long<br />

column oven<br />

• RS232 interface<br />

• Peltier column<br />

thermostat heats to<br />

85°C and cools to 5°C<br />

• Temperature may be<br />

fixed or changed via<br />

step or linear gradient<br />

• Large column<br />

compartment holds five<br />

columns up to 1" o.d.<br />

and 35cm in length<br />

Access to Columns Cover Cover Cover Door<br />

Temperature Range: 30–99°C 30–75°C 0–95°C 5–85°C<br />

Column Capacity 1–2, depending on size 1 column per oven 1–2, depending on size 5<br />

(Excluding Guards):<br />

Maximum Column o.d.: 1/2" 1/4" 1/2" 1"<br />

Maximum Column 30cm 30cm 30cm 35cm<br />

Length:<br />

Cavity Dimensions: 1" H x 2" W x 14" L<br />

(2.6cm H x 5.1cm W x<br />

0.79" H x 0.75" W x 14.2" L<br />

(2cm H x 1.9cm W x 36cm L)<br />

0.9" H x 1.7" W x 14.2" L<br />

(2.3cm H x 4.2cm W x<br />

15.4" H x 3.3" W x 2" L<br />

(39.2cm H x 8.5cm W x 5cm L)<br />

35.6cm L)<br />

36.1cm L)<br />

Temperature Accuracy: ±0.5°C ±0.5°C ±0.5°C ±0.2°C<br />

Temperature Stability: ±0.2°C ±0.2°C ±0.2°C ±0.1°C<br />

Operating Voltage: 120V/60Hz, 240V/50Hz, 250W 120V/60Hz , 240V/50Hz, 100W 120V/60Hz , 240V/50Hz, 250W 100–245VAC, 50/60 Hz, 100W<br />

Warranty: 1 year 1 year 1 year 1 year<br />

Ordering Information<br />

Model <strong>Grace</strong> ® 7971R <strong>Grace</strong> ® 7990R w/Controller <strong>Grace</strong> ® 7956R w/Controller Jetstream Plus 2<br />

Part No. Part No. Part No. Part No.<br />

Block heater with one<br />

block set and RS232<br />

Single output controller,<br />

long column oven and<br />

RS232<br />

Dual output controller,<br />

2 long column ovens,<br />

and RS232 interface<br />

Heater/Chiller with<br />

RS232<br />

Jetstream 2 Plus Heater/<br />

Chiller, 75cm cable<br />

Jetstream 2 Plus Heater/<br />

Chiller, 150cm cable<br />

5135360, 110V<br />

5135361, 220V<br />

—<br />

—<br />

— — —<br />

5109747, 110V<br />

5111660, 220V<br />

5109749, 110V<br />

5111662, 220V<br />

— —<br />

— —<br />

— —<br />

5111646, 110V<br />

5111645, 220V<br />

— — — 531102, dual voltage<br />

— — — 531202, dual voltage<br />

—<br />

16<br />

www.discoverysciences.com


analytical hplc<br />

Column Heaters<br />

Alltech ® and Eppendorf ® Models<br />

Alltech ® 631<br />

Eppendorf ® TC-50<br />

Temperature Controller<br />

Eppendorf ® CH-30<br />

Eppendorf ® CH-430 and CH-460<br />

hplc instruments<br />

6219<br />

• Microprocessor<br />

controlled<br />

temperature<br />

• Column preheater<br />

to improve<br />

performance<br />

• Available in<br />

stainless steel or<br />

PEEK flow paths<br />

2336<br />

• Controls any<br />

Eppendorf Heater<br />

• Adjust<br />

temperature in<br />

0.1°C increments<br />

• Monitor “set” and<br />

“read” on the LED<br />

• Remote external<br />

ON or OFF feature<br />

2290<br />

• Fits one column<br />

up to 1/2” o.d. and<br />

30cm in length<br />

• Supports all<br />

column lengths<br />

to 30cm<br />

• Requires TC-50<br />

temperature<br />

controller<br />

2337<br />

• Holds four columns and two<br />

Rheodyne valves<br />

• CH-430 holds columns up to 30cm<br />

in length<br />

• CH-460 holds columns up to 50cm<br />

in length<br />

• Ideal for multi-column GPC, sample<br />

injection or column switching<br />

applications<br />

• Adjust temperature in 0.1°C increments<br />

• Requires TC-50 temperature controller<br />

Specifications<br />

Access To Columns Drawer Controller Cover Cover Cover<br />

Temperature Range: Ambient–85°C Ambient–150°C Ambient–150°C Ambient–150°C Ambient–150°C<br />

Column Capacity 2 NA 1 4 4<br />

(Excluding Guards):<br />

Maximum Column o.d.: 1/2" NA 1/2" 1/2" 1/2"<br />

Maximum Column 30cm NA 30cm 30cm 50cm<br />

Length:<br />

Cavity Dimensions: 1.8" H x 5" W x 16.5" D<br />

(5cm H x 13cm W x<br />

42cm D)<br />

3.25" H x 7" W x 8.5" D<br />

(8.3cm H x 17.8cm W x<br />

21.6cm D)<br />

3" H x 2.75" W x 19.5" D<br />

(7.6cm H x 7cm W x<br />

49.5cm D)<br />

3.5" H x 6.5" W x 21" D<br />

(8.9cm H x 16.5cm W x<br />

53cm D)<br />

3.5" H x 6.5" W x 29.5" D<br />

(8.9cm H x 16.5cm W x<br />

74.9cm D)<br />

Temperature Accuracy: ±1°C ±1°C ±0.5°C ±0.5°C ±0.5°C<br />

Temperature Stability: ±0.10°C ±0.10°C ±0.2°C ±0.2°C ±0.2°C<br />

Operating Voltage: 110V, 220V 110V, 220V 120V/60Hz, 240V/50Hz<br />

250 watts<br />

120V/60Hz, 240V/50Hz<br />

100 watts<br />

120V/60Hz, 240V/50Hz<br />

250 watts<br />

Inlet Preheaters: Included NA Included Four sets included<br />

Heater Element: Microprocessor<br />

controlled<br />

NA<br />

125W vulcanized to<br />

heating block<br />

300W (CH-430) or 500W<br />

(CH-460) vulcanized to<br />

heating block<br />

Heater Block: NA NA Aluminum, two-part oven Aluminum, two-part oven<br />

Sensor: NA NA 1000Ω Platinum RTD 1000Ω Platinum RTD<br />

Thermal Cut-Out: NA 155°C ±5°C temperature 155°C ±5°C temperature<br />

limit<br />

limit<br />

TC-50 Temperature No NA Yes Yes Yes<br />

Controller required:<br />

Warranty: 1 year 1 year 1 year 1 year 1 year<br />

CH-430<br />

CH-460<br />

Ordering Information<br />

Model Alltech ® 631<br />

Eppendorf ® TC-50<br />

Temperature Controller Eppendorf ® CH-30* Eppendorf ® CH-430* Eppendorf ® CH-460*<br />

Description Column Heater, PEEK Temperature Controllers Column Heaters Column Heaters Column Heaters<br />

Part No. Part No. Part No. Part No. Part No.<br />

110V 631100 85910 85975 85980 85971<br />

220V 631200 85911 85976 85981 85972<br />

Description<br />

Column Heater, SS<br />

110V 631300 — — — —<br />

220V 631400 — — — —<br />

*Eppendorf ® column heaters require the TC-50 controller.<br />

www.discoverysciences.com 17


analytical hplc<br />

hplc instruments<br />

HPLC Pumps<br />

We Have a Pump for Every Need and Budget<br />

Use this pump feature comparison chart to choose the pump that is best for your application, then go to the catalog page for<br />

more information.<br />

Model <strong>Catalog</strong> Page Flow Range Isocratic/Gradient Pressure Monitoring<br />

301 HPLC Pump 18 0.01 - 10mL/min isocratic No<br />

426 HPLC Pump 18 0.01 - 10mL/min isocratic Yes<br />

626 HPLC Pump 19 0.001 - 12mL/min isocratic or binary gradient Yes<br />

627 Preparative Pump 19 0.01 - 100mL/min isocratic or binary gradient Yes<br />

442 Binary Gradient Pump 20 0.001 - 5.000mL/min binary gradient Yes<br />

801 Ultra-High Pressure Pump 20 0.001 - 5.000mL/min isocratic or binary gradient Yes<br />

727 Quaternary Gradient Pump 21 0.001 - 5.000mL/min quaternary gradient Yes<br />

Alltech ® 426 and 301 HPLC Pumps<br />

3 yr<br />

warranty<br />

best<br />

value<br />

6772<br />

Both pumps are available in stainless steel or biocompatible PEEK.<br />

Low-Cost, High-Performance Isocratic Pumps<br />

Both pumps feature:<br />

• Built-in pulse dampener and rapid refill for<br />

pulse-free operation<br />

• Self-flushing pump head for longer seal-life<br />

• Automatic prime/purge system for easy priming<br />

• Wide flow range for broad HPLC work, including<br />

semi-preparative applications<br />

• EZChrom driver and cables included<br />

The Model 426 has these additional features:<br />

• User-settable upper and lower pressure limits<br />

• Pressure monitoring on the LCD<br />

• Interfacing features for convenient pump control<br />

Model 301 HPLC Pump 426 HPLC Pump<br />

Flow Range: 0.01–10mL/min 0.01–10mL/min<br />

Isocratic/gradient: Isocratic Isocratic<br />

Pressure Monitoring: No Yes<br />

Max. Operating<br />

Pressure:<br />

6000psig (SS),<br />

5000psig (PEEK)<br />

6000psig (SS),<br />

5000psig (PEEK)<br />

Flow Precision: 0.2% RSD 0.2% RSD<br />

Flow Accuracy: ±2.0% ±2.0%<br />

Dimensions:<br />

6" H x 11" W x 18" D<br />

(15cm H x 26cm W x<br />

46cm D)<br />

6" H x 11" W x 18" D<br />

(15cm H x 26cm W x<br />

46cm D)<br />

Weight: 30lb (14kg) 30lb (14kg)<br />

Warranty:<br />

3-year parts, excluding<br />

seals, check valves,<br />

and pulse dampener;<br />

1-year labor<br />

3-year parts, excluding<br />

seals, check valves,<br />

and pulse dampener;<br />

1-year labor<br />

Drivers: EZChrom Elite/EZStart EZChrom Elite/EZStart<br />

more info<br />

All pumps can be controlled by EZChrom Elite or EZStart<br />

chromatography data systems. The driver and cables are included<br />

with every pump. If you wish to separately purchase the Driver<br />

Kit, please refer to part number 8619000.<br />

Model 426 and 301 HPLC Pumps<br />

Description<br />

Part No.<br />

Model 426 HPLC Pump<br />

PEEK, 85–265VAC, 47–63Hz 426150<br />

Stainless Steel, 85–265VAC, 47–63Hz 426250<br />

Model 301 HPLC Pump<br />

PEEK, 85–265VAC, 47–63Hz 301150<br />

Stainless Steel, 85–265VAC, 47–63Hz 301250<br />

Model 426 and 301 HPLC Replacement Parts<br />

Description<br />

Part No.<br />

Pump Head Kit, PEEK 120800<br />

Pump Head Kit, Stainless Steel 120799<br />

Piston Seal Kit 120680<br />

Piston 121486<br />

Check Valve Kit, PEEK 060141<br />

Check Valve Kit, Stainless Steel 120679<br />

Note: All replacement parts contain parts for one pump head only.<br />

18<br />

www.discoverysciences.com


analytical hplc<br />

HPLC Pumps<br />

Alltech ® 626 HPLC Pump<br />

Alltech ® 627 Prep Pump<br />

High-Performance<br />

Isocratic or Binary<br />

Gradient Pump<br />

3 yr<br />

warranty<br />

6773<br />

Ideal for Scale-up<br />

Work, Semi-Prep and<br />

Preparative HPLC<br />

3 yr<br />

warranty<br />

6774<br />

hplc instruments<br />

• Suitable for standard and microflow applications<br />

• Dual-piston mechanism for pulse-free operation<br />

• Built-in low dead volume pulse dampener<br />

• Self-flushing pump head for longer seal life<br />

• EZChrom driver and cables included<br />

The Model 626 Pump is a rugged and reliable component<br />

for a basic analytical system, a sophisticated method<br />

development system, or for general laboratory or industrial<br />

use. It is available in either traditional 316 stainless steel<br />

or biocompatible PEEK.<br />

Buy a single 626 Pump for isocratic applications. Add a<br />

second 626 pump for high-pressure binary gradients.<br />

626 HPLC Pump Specifications<br />

Flow Range:<br />

0.001–12mL/min<br />

Fluid Path:<br />

PEEK or Stainless Steel<br />

Isocratic/gradient: Isocratic or binary gradient<br />

Pressure Monitoring: Yes<br />

Max. Operating Pressure: 6000psig (SS), 5000psig (PEEK)<br />

Flow Precision:<br />

0.2% RSD<br />

Flow Accuracy: ±2.0%<br />

Dimensions:<br />

6" H x 11" W x 18" D<br />

(15cm H x 26cm W x 46cm D)<br />

Weight:<br />

30lb (14kg)<br />

Warranty:<br />

3-year parts, excluding seals, check valves,<br />

and pulse dampener; 1-year labor<br />

Gradient Mixing Mode: High-Pressure<br />

Profiles:<br />

Programmable Multi-step<br />

Gradient Programming: 10 methods with up to 100 lines per method<br />

Drivers:<br />

EZChrom Elite/EZStart<br />

Model 626 HPLC Pump<br />

Description<br />

Part No.<br />

Isocratic System<br />

PEEK, 85–265VAC, 47–63Hz 626150<br />

Stainless Steel, 85–265VAC, 47–63Hz 626250<br />

Binary Gradient System (Includes 2 pumps, mixing tee,<br />

SCU Keypad Controller, tubing, and fittings)<br />

PEEK, 85–265VAC, 47–63Hz 626350<br />

Stainless Steel, 85–265VAC, 47–63Hz 626450<br />

Accessories and Replacement Parts for Model 626<br />

Description<br />

Part No.<br />

Accessories<br />

SCU Keypad Controller 726300<br />

High-pressure Gradient Kit, PEEK<br />

105626<br />

(Includes controller, mixing tee, fittings, and tubing)<br />

High-pressure Gradient Kit, Stainless Steel<br />

105624<br />

(Includes controller, mixing tee, fittings, and tubing)<br />

Replacement Parts<br />

Piston Seal Kit 160566<br />

Piston 160565<br />

Check Valve Kit, Stainless Steel 120679<br />

Check Valve Kit, PEEK 060141<br />

Note: All replacement parts contain parts for one pump head only.<br />

• Dual-piston mechanism for pulse-free operation<br />

• Built-in low dead volume pulse dampener<br />

• Self-flushing pump head for longer seal life<br />

• Isocratic or high-pressure binary gradient<br />

• EZChrom driver and cables included<br />

The Model 627 Preparative Pump delivers the accuracy and<br />

precision of a standard analytical pump at flow rates up to<br />

100mL/min.<br />

627 Preparative Pump Specifications<br />

Flow Range:<br />

0.01–100mL/min<br />

Fluid Path:<br />

PEEK or Stainless Steel<br />

Isocratic/gradient: Isocratic or binary gradient<br />

Pressure Monitoring: Yes<br />

Max. Operating Pressure: 4000psig (both SS and PEEK)<br />

Flow Precision:<br />

0.5% RSD<br />

Flow Accuracy: ±2.0%<br />

Dimensions:<br />

6" H x 11" W x 18" D<br />

(15cm H x 26cm W x 46cm D)<br />

Weight:<br />

35lb (16kg)<br />

Warranty:<br />

3-year parts, excluding seals, check valves,<br />

and pulse dampener; 1-year labor<br />

Gradient Mixing Mode: High-Pressure<br />

Profiles:<br />

Programmable Multi-step<br />

Gradient Programming: 10 methods with up to 100 lines per method<br />

Drivers:<br />

EZChrom Elite/EZStart<br />

Model 627 Preparative Pump<br />

Description<br />

Part No.<br />

Isocratic System<br />

PEEK, 85–265VAC, 47–63Hz 627150<br />

Stainless Steel, 85–265VAC, 47–63Hz 627250<br />

Binary Gradient System (Includes 2 pumps, mixing tee,<br />

SCU Keypad Controller, tubing, and fittings)<br />

PEEK, 85–265VAC, 47–63Hz 627350<br />

Stainless Steel, 85–265VAC, 47–63Hz 627450<br />

Accessories and Replacement Parts for Model 627<br />

Description<br />

Part No.<br />

Accessories<br />

SCU Keypad Controller 726400<br />

High-pressure Gradient Kit, PEEK<br />

105625<br />

(Includes controller, mixing tee, fittings, and tubing)<br />

High-pressure Gradient Kit, Stainless Steel<br />

105628<br />

(Includes controller, mixing tee, fittings, and tubing)<br />

Replacement Parts<br />

Piston Seal Kit 120681<br />

Piston 121504<br />

Check Valve Kit, Stainless Steel 120679<br />

Check Valve Kit, Metal-Free 060141<br />

Note: All replacement parts contain parts for one pump head only.<br />

related products<br />

Looking for preparative columns and accessories?<br />

See our prep section, pages 148–183.<br />

www.discoverysciences.com 19


analytical hplc<br />

hplc instruments<br />

HPLC Pumps<br />

Alltech ® 442 Binary<br />

Gradient Pump<br />

3 yr<br />

warranty<br />

442 Binary Gradient Pump Specifications<br />

Flow Range:<br />

0.001–10mL/min<br />

Fluid Path:<br />

PEEK or Stainless Steel<br />

Isocratic/gradient: Binary<br />

Pressure Monitoring: Yes<br />

Max. Operating Pressure: 6000psig (Stainless Steel) 5000psig (PEEK)<br />

Flow Precision:<br />

0.5% RSD<br />

Flow Accuracy:<br />

±1% of full-scale pressure<br />

Dimensions:<br />

7" H x 10.5" W x 15.25" D<br />

(18cm H x 27cm W x 39cm D)<br />

Weight:<br />

24lb (11kg)<br />

Warranty:<br />

3-year parts, excluding seals, check valves,<br />

and pulse dampener; 1-year labor<br />

Gradient Mixing Mode: High-pressure<br />

Profiles:<br />

Programmable Multi-step through EZChrom<br />

Elite<br />

Gradient Programming: 0–100% in 0.1% increments<br />

Control:<br />

EZChrom Elite/EZStart or<br />

SCU Keypad Controller<br />

7423<br />

Alltech ® 801<br />

Ultra High-Pressure<br />

HPLC Pump<br />

3 yr<br />

warranty<br />

801 High-Pressure Pump Specifications<br />

Flow Range:<br />

0.001–5.000ml/min<br />

Fluid Path:<br />

Stainless Steel<br />

Isocratic/gradient: Isocratic<br />

Pressure Monitoring: Yes<br />

Max. Operating 18,000psig<br />

Pressure:<br />

Flow Precision: 0.2% RSD<br />

Flow Accuracy:


analytical hplc<br />

HPLC Pumps<br />

Alltech ® 727 Quaternary Gradient HPLC Pump<br />

High-Pressure Quaternary Gradients for Standard<br />

or Micro Applications<br />

• EZChrom driver and cables included<br />

• Integrated pulse dampener reduces pulsations and<br />

mixes gradients accurately<br />

• Self-flushing pump heads extend seal life<br />

• Easy gradient programming with hand-held control<br />

module<br />

The Model 727 Quaternary Gradient Pump combines four<br />

high-performance pumps in a single cabinet. The system<br />

controller controls each pump independently, for accurate<br />

gradients. Flow rates are programmable from 0.001mL/min<br />

to 5.000mL/min making it suitable for standard or micro<br />

applications. The 727 pump is available in 316 stainless steel<br />

or biocompatible PEEK.<br />

new<br />

7425<br />

3 yr<br />

warranty<br />

hplc instruments<br />

727 Quaternary Gradient Pump Specifications<br />

Max. Operating Pressure: 6000psig (Stainless Steel)<br />

5000psig (PEEK)<br />

Fluid Path:<br />

PEEK or Stainless Steel<br />

Flow Rate Range: 0.001–5.000mL/min<br />

Flow Precision:<br />

0.5% RSD<br />

Flow Accuracy: ±2.0%<br />

Gradient Mixing Mode: High-pressure Gradient<br />

Profiles:<br />

Programmable Multi-step<br />

Gradient Programming: 0–100% in 0.1% increments<br />

Dimensions:<br />

9" H x 15" W x 20.5" D<br />

(23cm H x 38cm W x 52cm D)<br />

Weight:<br />

50lb (23kg)<br />

Warranty:<br />

3-year parts, excluding seals, check valves,<br />

and pulse dampener; 1-year labor<br />

Control:<br />

EZChrom Elite/EZStart or<br />

SCU Keypad Controller<br />

Model 727 Quaternary Gradient HPLC Pump<br />

Description<br />

Part No.<br />

Model 727 Quaternary Gradient Pump<br />

PEEK, 85–265VAC, 47–63Hz 8618931<br />

Stainless Steel, 85–265VAC, 47–63Hz 8618930<br />

Optional Controller<br />

SCU Keypad Controller 726300<br />

Note: the SCU Keypad Controller is necessary to program gradients if you do not have<br />

EZChrom Software.<br />

Replacement Parts for Model 727<br />

Description<br />

Part No.<br />

727 Aqueous Seal Kit 5mL (for 1 head) 8619072<br />

727 Organic Seal Kit 5mL (for 1 head) 8619073<br />

Piston Assembly 5mL (for 1 head) 8619077<br />

PEEK Check Valve Kit (for 1 head) 8619079<br />

Stainless Steel Check Valve Kit (for 1 head) 8619078<br />

Note: All replacement parts contain parts for one pump head only.<br />

related products<br />

Looking for a convenient way to order<br />

all the essential accessories for system<br />

start-up? See page 121 for our HPLC<br />

accessory and fitting kits.<br />

related products<br />

Looking for pump accessories?<br />

See pages 132–135.<br />

www.discoverysciences.com 21


analytical hplc<br />

hplc instruments<br />

Data Systems<br />

EZStart Chromatography Data System<br />

Affordable, Simple-to-use Chromatography<br />

Data System<br />

• PC-based data handling at integrator-like prices<br />

• Optional control of instruments from many vendors<br />

• Upgradeable to EZChrom Elite<br />

Based on the EZChrom Elite software package, EZStart is<br />

the ideal solution for laboratories wanting a simple-to-use<br />

chromatography data system with comprehensive software<br />

features and optional instrument control. It is intended to<br />

provide the basic requirements for data acquisition and<br />

instrument control from a single workstation.<br />

Operation is Reduced to Three Easy Steps:<br />

1. Simple configuration. Collects data from any instrument<br />

generating an analog output using the software’s data<br />

interface.<br />

2. Run in one window. Set up all runs from a single window<br />

using simple wizards.<br />

3. Generate graphic reports. Select from existing templates<br />

or customize with the report editor.<br />

PE Interface Control<br />

• Preserve your investment in existing PE Interface<br />

hardware<br />

• Take advantage of advances in computer and software<br />

development<br />

EZStart 3.1 with PE Interface Control License allows<br />

PerkinElmer Inc’s interface boxes to be used as analog<br />

to digital converters to interface chromatography detectors<br />

to EZStart. Control the PE Turbochrom, Turbochrom EL,<br />

TotalChrom ® , and ACCESS*CHROM interfaces from EZStart<br />

to take advantage of the software benefits while retaining the<br />

investment in hardware.<br />

PE Interface Control Software Controls the<br />

Following PerkinElmer ® Interfaces:<br />

- Series 900 Model 941/941A (RS232 communications)<br />

- Series 900 Models 950/950A, 960/960A, 970/970A<br />

(GPIB communications)<br />

- NCI 901/902 (GPIB and RS232 communications)<br />

GPIB PE Interfaces require a GPIB interface card for EZStart<br />

(Part No. 111420, PCI slotted card). Serial PE Interfaces<br />

require available RS232 ports.<br />

Computer Requirements:<br />

• Windows Vista ® “Business Edition”<br />

• Windows XP ® Professional (SP2) or<br />

2000 Professional (SP4)<br />

• Internet Explorer ® 6.0 or 7.0<br />

• Microsoft ® .NET version 2.0<br />

• 1.0 GHz CPU minimum<br />

• 512 MB RAM minimum<br />

• 10 GB free disk space<br />

• PCI slots for GPIB, SCSI<br />

• Multiport serial or Ethernet cards may be required<br />

EZStart Chromatography Data System<br />

Description<br />

Part No.<br />

EZStart 3.1 with PE Interface Control* 1886023<br />

IEEE-488 PCI Card (for PE-Nelson 700 and 900 series 111420<br />

intelligent interfaces)**<br />

*One PE interface is required but not included.<br />

**Available PCI slot in PC required.<br />

more info<br />

For more information on EZStart PE Interface Control Software,<br />

request sheet M098. Also available on our website.<br />

EZStart Software with SS420X Interface<br />

Description<br />

Part No.<br />

120V 1886011<br />

220V 1886211<br />

100V (Japan) 1886311<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

7241_tech<br />

22<br />

www.discoverysciences.com


analytical hplc<br />

Data Systems<br />

EZChrom Elite Chromatography Data System<br />

Premier Chromatography Data System for<br />

Advanced Needs<br />

Use EZChrom Elite software to create a fully integrated system<br />

to control operation, collect and store results, and record all<br />

settings.<br />

Multi-vendor instrument control: EZChrom Elite software<br />

works with most leading HPLC and GC instruments and<br />

components—over 300 vendors are currently represented,<br />

and more are added continuously.<br />

Complete data analysis: Full features and ease-of-use<br />

to meet your needs today and into the future. Collect<br />

chromatography runs and apply a variety of analysis tools<br />

including quantitation techniques and calibration curves.<br />

You can view the results graphically and generate a variety<br />

of outputs for reports.<br />

GLP/GMP features: Complete audit trails and system logs to<br />

document and record all changes, user security for access and<br />

operational privileges, and electronic signatures and sign-offs.<br />

EZChrom Elite Stand-Alone Package<br />

The EZChrom Elite Stand-Alone software package<br />

provides the full functionality of EZChrom Elite software for<br />

an individual PC. The stand-alone configurations let you<br />

perform all the instrument control and data processing for<br />

1–4 instruments. Each EZChrom Elite Stand Alone package<br />

contains the full functionality of EZChrom Elite software.<br />

Computer Requirements:<br />

• Windows Vista ® “Business Edition”<br />

• Windows XP ® Professional (SP2) or<br />

2000 Professional (SP4)<br />

• Internet Explorer ® 6.0 or 7.0<br />

• Microsoft ® .NET version 2.0<br />

• 1.0 GHz CPU minimum<br />

• 512 MB RAM minimum<br />

• 10 GB free disk space<br />

• PCI slots for GPIB, SCSI<br />

• Multiport serial or Ethernet cards may be required<br />

hplc instruments<br />

EZChrom Elite Ordering Information<br />

Description<br />

Part No.<br />

EZChrom Elite Stand-Alone Software* 2111696<br />

EZChrom Elite Stand-Alone Additional License 2111697<br />

EZChrom Elite Offline Re-Processing Software* 2111694<br />

EZChrom Elite Offline Re-Processing Additional License 2111695<br />

Dual-Channel A/D Interface for RS-232 8605415<br />

Dual-Channel A/D Interface for Ethernet/LAN 8619130<br />

*Licensed for a single instrument. Additional licenses can be purchased for up to<br />

three additional instruments.<br />

www.discoverysciences.com 23


analytical hplc<br />

hplc columns | introduction<br />

Analytical HPLC Column<br />

Introduction<br />

<strong>Grace</strong> ® Key Column Families<br />

Single-Source Solution for Discovery to Recovery<br />

Applications<br />

HPLC is commonly used in a wide range of applications,<br />

including drug discovery and purification for the<br />

pharmaceutical and biotechnology industries, environmental<br />

analysis, forensics, petrochemical analysis, food, cosmetics,<br />

and vitamins. The combined premier product lines of Alltech ® ,<br />

Davisil ® , Flexit, Grom, Jones Chromatography,<br />

Modcol ® , and Vydac ® create a single-source solution for<br />

HPLC columns and accessories from discovery to recovery.<br />

Our column families include reversed-phase, normal-phase,<br />

HILIC, ion-exchange, ion-exclusion, size-exclusion, and<br />

affinity stationary phases for small- and large-molecule<br />

separations, and our column formats maximize their<br />

performance. Our product range includes standard and<br />

custom columns for analytical separations, preparative<br />

phases for scale up, bulk packings that customers can<br />

pack in their own columns, and accessories to maintain<br />

separation ruggedness and quality.<br />

To help select the appropriate column for your application,<br />

we describe key column families and highlight unique phases<br />

within these families. Whether the most important factor<br />

is analysis speed, column bleed, pH stability, resolution,<br />

adjustable selectivity, or analyte molecular weight, <strong>Grace</strong><br />

offers a column to suit your application.<br />

Column Families Suitable for Small Molecules<br />

(


analytical hplc<br />

Analytical HPLC Column Introduction<br />

Column Families Suitable for Small Molecules<br />

(2000 Molecular Weight)<br />

Alltech ® Platinum Columns<br />

Alternate retention and selectivity for<br />

polar and nonpolar analytes available in<br />

sub 2µm particle sizes<br />

Alltech ® Platinum phases have a controlled polar silica<br />

surface which provides enhanced polar selectivity (EPS)<br />

in addition to reversed-phase retention. C18 and EPS<br />

C18 columns are a complimentary duo to separate polar<br />

and nonpolar analytes.<br />

Differentiated Phases: C18, EPS C18<br />

Specifications: Spherical silica, monomerically bonded,<br />

proprietary endcapping, 100Å pore size<br />

Formats: Microbore, Expedite, Rocket, Solvent-<br />

Reducer, Analytical, Prep<br />

Vydac ® MS Columns<br />

Next generation Vydac ® media from the leader<br />

in peptide and protein separations<br />

Vydac ® MS columns provide unique selectivity and<br />

exceptional protein recovery. They require less TFA in<br />

the mobile phase for good peak shape, which increases<br />

microbore sensitivity of peptides and proteins by<br />

reducing “quenching”. Vydac ® MS columns are also<br />

applicable to hydrophobic proteins and peptide mapping.<br />

Differentiated Phases: C18, C8, C4<br />

Specifications: Spherical silica, polymerically and<br />

monomerically bonded, endcapped, 300Å pore size<br />

Formats: Capillary, Microbore, Expedite, Rocket,<br />

Solvent-Reducer, Analytical, Prep<br />

hplc columns | introduction<br />

<strong>Grace</strong>Smart Columns<br />

Vydac ® ProZap Columns<br />

Classic reversed-phase and premium<br />

performance at an exceptional value<br />

<strong>Grace</strong>Smart HPLC phases use high purity silica.<br />

Which translates into symmetrical peaks for acids and<br />

bases, and predictable reversed-phase selectivity.<br />

Whether routine analysis or new method development,<br />

use individually tested <strong>Grace</strong>Smart columns to get<br />

premium performance at exceptional value.<br />

Differentiated Phases: C18<br />

Specifications: Spherical silica, monomerically bonded,<br />

endcapped, 120Å pore size<br />

Format: Analytical<br />

High-speed, high-efficiency columns<br />

for fast protein analysis<br />

Short 10 and 20mm ProZap columns with 1.5µm<br />

particles provide high-speed protein and life science<br />

separations. Sharp, efficient peaks maximize method<br />

sensitivity.<br />

Differentiated Phases: C18<br />

Specifications: Sub 2µm spherical silica, proprietary<br />

bonding and endcapping, 500Å pore size<br />

Format: Expedite<br />

<strong>Grace</strong>Alpha Columns<br />

Vydac ® Everest ® Columns<br />

A New Silica Generation<br />

New silica from <strong>Grace</strong> with high porosity surface<br />

and dense core ideal for scale-up applications.<br />

While high porosity surface increases mass transfer<br />

results in increased column efficiencies and loading<br />

capacity, dense core and highly spherical shape yields<br />

mechanically robust particle.<br />

Differentiated Phases: C18, C8, and Silica<br />

Specifications: High purity spherical silica with high<br />

porosity surface and dense core<br />

Formats: Analytical, Prep<br />

For peptide separations, peptide<br />

mapping and proteomics applications<br />

High-capacity Everest ® C18 columns are recommended<br />

as the first choice in peptide separations. Everest ®<br />

offer high capacity to resolve complex samples such as<br />

protein digests.<br />

Differentiated Phases: C18<br />

Specifications: Spherical silica, monomerically bonded,<br />

endcapped, 300Å pore size<br />

Formats: Capillary, Microbore, Expedite, Analytical<br />

www.discoverysciences.com 25


analytical hplc<br />

hplc columns | introduction<br />

HPLC Column Selection<br />

A Comparison of Reversed-Phase Columns<br />

Based on the widely accepted work and data of Drs. Lloyd Snyder and John Dolan. 1,2 <strong>Grace</strong> has developed this column selection<br />

tool for choosing reversed phase HPLC columns based on peak capacities and column selectivity of polar and nonpolar compounds.<br />

Typically, chromatographers choose HPLC columns by comparing physical characteristics, such as surface area and carbon load.<br />

Often, this does not provide enough information about selectivity or capacity for adequate column selection. This chart provides a<br />

reliable means of choosing HPLC columns based on acidic, basic, and hydrophobic character.<br />

The Snyder/Dolan column test procedure has been described in a series of publications. Based on retention data for a series of<br />

standard mixtures and the same separation conditions (50% acetonitrile/buffer; pH 2.8 and 7.0; 35°C), reversed-phase columns<br />

are characterized by five column-selectivity parameters: hydrophobicity (H), steric interaction (S*), hydrogen-bond acidity A,<br />

basicity (B), and relative silanol ionization or cation-exchange capacity C. Here we have chosen to graphically highlight data<br />

for H , A, and C, with C results at pH 7.0. Hydrophobicity (H) is often the primary analyte interaction with reversed phase<br />

columns and indicates overall capacity. Secondary interactions are often polar interactions with basic analytes. The degree of<br />

unprotonated base interaction A and protonated base interaction C with the packing material is measured and represented here.<br />

Directions for Using the Column Chart<br />

The chart lists the columns in descending order of hydrophobic capacity (H) . To find similar HPLC columns to test as<br />

back-up columns, follow these steps.<br />

1) Find the column you are currently using and note neighboring columns which have similar (H) capacity factors.<br />

2) Compare the values for interaction of polar compounds ( A and C ).<br />

If there is more than one choice for a back-up column, then compare your actual sample to the test probes. If your<br />

sample is nonpolar, then place more emphasis on hydrophobic values. If your sample is basic (polar), then pay special<br />

attention to A and C and determine if your sample will be protonated ( A) or unprotonated (C ) and place greater<br />

emphasis on one of these values.<br />

Key to Chart<br />

Hydrophobic Indicator<br />

A Hydrogen bonding<br />

Indicator—pH 2.8<br />

(Protonated under<br />

acidic conditions)<br />

C Cation Exchange<br />

Indicator—pH 7.0<br />

(Unprotonated under<br />

neutral conditions)<br />

Manufacturer Column Selectivity Parameters<br />

Manufacturer Column Selectivity Parameters<br />

ZirChrom ZirChrom ® -PBD C18 A C 1.284 Merck LiChrospher ® 100 RP-18 C A<br />

1.006<br />

YMC J’Sphere ® H80 C18 C A<br />

1.132<br />

Bischoff ProntoSIL 120-5-C18 H C A<br />

1.005<br />

Restek Allure ® C18 C A<br />

1.116<br />

Shiseido CAPCELL C18 M G C A<br />

1.005<br />

Phenomenex Ultracarb ® ODS (30) C A<br />

1.114<br />

<strong>Grace</strong> (Jones) Genesis ® 120 C18 C A<br />

1.005<br />

YMC YMC ® Pack Pro C18 RS C A<br />

1.114<br />

Bischoff EU Reference Column C18 C A<br />

1.004<br />

<strong>Grace</strong> (Alltech) Adsorbosphere UHS C18 C<br />

A<br />

1.103<br />

<strong>Grace</strong> (Alltech) Allsphere ODS2 CA<br />

1.004<br />

Thermo/Hypersil Hypersil ® BetamaxNeutral C18 C A<br />

1.098<br />

Merck Purospher ® STAR RP18e C A<br />

1.003<br />

Agilent Zorbax Extend C18 C A<br />

1.098<br />

Merck Chromolith ® RP18e C A<br />

1.003<br />

Agilent Zorbax C18 C A<br />

1.089<br />

Phenomenex Luna ® C18(2) C A<br />

1.002<br />

Beckman Ultrasphere ® ODS C A<br />

1.085<br />

Varian Pursuit ® C18 C A<br />

1.001<br />

<strong>Grace</strong> (Alltech) Alltima HP C18 High Load C A<br />

1.080<br />

MacMod/ACT ACE ® 5 C18 C A<br />

1.000<br />

Agilent Zorbax Rx-18 C A<br />

1.077<br />

Tosoh TSKgel ® Super-ODS C A<br />

0.998<br />

Agilent Zorbax Eclipse XDB-C18 C A<br />

1.077<br />

Agilent Zorbax StableBond 80A C18 C A<br />

0.996<br />

Supelco Ascentis ® C18 C A<br />

1.077<br />

Phenomenex Prodigy ODS(2) C A<br />

0.995<br />

Macherey Nagel Nucleodur ® C18 Gravity C A<br />

1.056<br />

Thermo/Hypersil Hypersil ® BDS C18 C A<br />

0.993<br />

<strong>Grace</strong> (Grom) Grom Sapphire 110 C18 C A<br />

1.055<br />

<strong>Grace</strong> (Alltech) Alltima C18 C A<br />

0.993<br />

Restek Restek ® Ultra C18 C A<br />

1.055<br />

<strong>Grace</strong> (Vydac) Vydac ® Everest ® C18 C A<br />

0.993<br />

Varian OmniSpher 5 C18 C A<br />

1.055<br />

Thermo/Hypersil Hypersil ® Beta Basic-18 C A<br />

0.993<br />

<strong>Grace</strong> (Vydac) Denali ® 120 C18 C A<br />

1.052<br />

GL Sciences Inertsil ® ODS-3 C A<br />

0.990<br />

Waters Symmetry ® C18 C A<br />

1.052<br />

<strong>Grace</strong> (Alltech) Adsorbosphere C18 A C<br />

0.989<br />

Akzo Nobel Kromasil ® 100-5C18 C A<br />

1.051<br />

Phenomenex Synergi Max-RP C18 C A<br />

0.989<br />

Waters Nova-Pak ® C18 C A<br />

1.049<br />

Shiseido CAPCELL C18 SG120 C A<br />

0.987<br />

Thermo/Hypersil Hypersil ® 100 C18 C A<br />

1.048<br />

<strong>Grace</strong> (Jones) Apex I C18 A C<br />

0.985<br />

MacMod/ACT ACE ® 5 C18-HL C A<br />

1.045<br />

Thermo/Hypersil Hypersil ® ODS-2 C A<br />

0.985<br />

ZirChrom ZirChrom ® -EZ C18 A<br />

C<br />

1.040<br />

<strong>Grace</strong> (Alltech) Alltima HP C18 C A<br />

0.985<br />

<strong>Grace</strong> (Grom) Grom Sil 120 ODS-5 ST C A<br />

1.035<br />

Waters Xterra ® MS C18 C A<br />

0.984<br />

Dionex Acclaim ® 120 C18 C A<br />

1.032<br />

Waters Symmetry ® 300 C18 C A<br />

0.984<br />

Waters Sunfire C18 C A<br />

1.031<br />

Supelco Discovery C18 C A<br />

0.984<br />

Agilent Zorbax Eclipse Plus C18 C A<br />

1.030<br />

Supelco Supelcosil LC-18-DB C A<br />

0.979<br />

Merck Superspher ® 100 RP-18e C A<br />

1.030<br />

Waters Spherisorb ® S5 ODSB A C<br />

0.975<br />

Shiseido CAPCELL C18 AG120 C A<br />

1.030<br />

Thermo/Hypersil Hypersil ® Bio Basic-18 C A<br />

0.974<br />

<strong>Grace</strong> (Grom) Grom Sil 120 ODS-3 CP C A<br />

1.029<br />

Thermo/Hypersil Hypersil ® ODS A C<br />

0.974<br />

Waters Delta-Pak C18 100A C A<br />

1.028<br />

Bischoff ProntoSIL 120-5-C18-AQ C A<br />

0.974<br />

Macherey Nagel Nucleodur ® Isis C A<br />

1.023<br />

<strong>Grace</strong> (Jones) Genesis ® 300 C18 C18 C A<br />

0.974<br />

Phenomenex Prodigy ODS (3) C A<br />

1.023<br />

Phenomenex Synergi Hydro-RP C18 C A<br />

1.022<br />

Phenomenex Luna C18 C A<br />

1.018<br />

Supelco Supelcosil LC-18 A C<br />

1.018<br />

YMC YMC ® Pro C18 C A<br />

1.015<br />

Phenomenex Onyx Monolithic C18 C A<br />

1.012<br />

Bischoff ProntoSIL SpheriBOND 80-5-ODS2 C A<br />

1.010<br />

<strong>Grace</strong> (Jones) Apex II C18 A C<br />

1.008<br />

Shiseido CAPCELL C18 UG120 C A<br />

1.007<br />

GL Sciences Inertsil ® ODS-2 C A<br />

1.007<br />

Bischoff Prontosil 200-5-C18 AQ C A<br />

0.974<br />

Agilent Zorbax C8 C A<br />

0.974<br />

Tosoh TSK gel ® ODS-80Ts A C<br />

0.971<br />

Waters Resolve C18 A C<br />

0.968<br />

Phenomenex Gemini ® C18 110A C A<br />

0.967<br />

<strong>Grace</strong> (Alltech) Econosil C18 C A<br />

0.966<br />

Phenomenex Aqua ® C18 C A<br />

0.966<br />

YMC YMC ® ODS-AQ C18 C A<br />

0.965<br />

Waters Spherisorb ® ODS-2 AC<br />

0.962<br />

Macherey Nagel Nucleosil ® 100-5-C18 HD C18 C A<br />

0.961<br />

26<br />

www.discoverysciences.com


analytical hplc<br />

<strong>Grace</strong> (Jones) Genesis ® 120 AQ C18 C A<br />

0.960<br />

Macherey Nagel Nucleodur ® Pyramid C A<br />

0.958<br />

Thermo/Hypersil Hypersil ® Elite C18 C A<br />

0.958<br />

Dionex Acclaim ® 300 C18 C A<br />

0.957<br />

Bischoff ProntoSIL 300-5-C18 H C A<br />

0.956<br />

Waters Delta-Pak C18 300A C A<br />

0.955<br />

Bischoff ProntoSIL HyperSORB 120 ODS A C<br />

0.951<br />

Thermo/Hypersil Hypersil ® PAH C18 A C<br />

0.949<br />

Bischoff ProntoSIL 120-5-C18 Aqplus C A<br />

0.947<br />

Phenomenex Jupiter ® 300 C18 C A<br />

0.945<br />

Varian Polaris ® C18-Ether 0.943<br />

CA<br />

Waters Atlantis ® T3 C18 AC<br />

0.941<br />

Tosoh TSKgel ® 80Ts QA C A<br />

0.940<br />

<strong>Grace</strong> (Alltech) Alltima C18-WP C A<br />

0.938<br />

Waters YMC ® Hydrosphere C18 C A<br />

0.937<br />

<strong>Grace</strong> (Alltech) Brava BDS C18 C A<br />

0.938<br />

Bischoff ProntoSIL 60-5 C8 SH 0.929<br />

C A<br />

Varian Polaris ® C18-A C A<br />

0.928<br />

YMC J’Sphere ® M80 C18 C A<br />

0.926<br />

Agilent Zorbax Eclipse XDB-C8 C A<br />

0.919<br />

Waters Atlantis ® dC18 b C A<br />

0.917<br />

Supelco Ascentis ® Express C8 C A<br />

0.915<br />

Thermo Hypersil ® GOLD aQ 0.915<br />

C A<br />

Phenomenex Selectosil C18 C A<br />

0.911<br />

Merck LiChrosorb ® RP-18 C A<br />

0.909<br />

<strong>Grace</strong> (Vydac) Vydac ® 218TP C18 C A<br />

0.909<br />

Waters Acquity UPLC ® BEH Shield RP18 EP C A<br />

0.907<br />

Macherey Nagel Nucleosil ® C18 0.906<br />

C A<br />

Agilent Zorbax StableBond 300A C18 C A<br />

0.905<br />

<strong>Grace</strong> (Alltech) Prosphere C18 300 AC<br />

0.903<br />

<strong>Grace</strong> (Vydac) Vydac ® 201TP C18 C A<br />

0.901<br />

Supelco Ascentis ® C-8 C A<br />

0.899<br />

Waters Nova-Pak ® C8 0.899<br />

CA<br />

Waters Symmetry ® C8 C A<br />

0.893<br />

YMC YMC ® Pro C8 C A<br />

0.890<br />

Agilent Zorbax Eclipse Plus C8 C A<br />

0.889<br />

Phenomenex Luna C8(2) C A<br />

0.889<br />

<strong>Grace</strong> (Alltech) Prevail C18 C A<br />

0.888<br />

<strong>Grace</strong> (Alltech) Prosphere 100 C18 AC<br />

0.883<br />

<strong>Grace</strong> (Alltech) Alltima AQ EP C A<br />

0.882<br />

Thermo/Hypersil Hypersil ® GOLD C18 C A<br />

0.881<br />

Phenomenex Synergi Fusion-RP EP C A<br />

0.879<br />

Phenomenex Luna C8 C A<br />

0.875<br />

<strong>Grace</strong> (Grom) Grom Sil 120 Octyl-6 MB C8 C A<br />

0.872<br />

<strong>Grace</strong> (Jones) Apex I C8 0.869<br />

Shiseido CAPCELL C18 A Q C A<br />

0.867<br />

Macherey Nagel Nucelosil ® 100-5-C8 HD C A<br />

0.865<br />

Akzo Nobel Kromasil ® 100-5C8 C A<br />

0.864<br />

<strong>Grace</strong> (Jones) Genesis ® 120 EC C8 C A<br />

0.863<br />

<strong>Grace</strong> (Alltech) Prevail Amide EP C A<br />

0.862<br />

Macherey Nagel Nucleosil ® ODS AC<br />

0.860<br />

Restek Ultra AQ C18 C A<br />

0.857<br />

Waters Sunfire C8 C A<br />

0.856<br />

Waters Acquity UPLC ® BEH C8 C A<br />

0.855<br />

Shiseido CAPCELL PAK C8 UG120 C A<br />

0.854<br />

Waters Symmetry ® Shield C18 AC<br />

0.850<br />

<strong>Grace</strong> (Alltech) Alphabond C18 A C<br />

0.845<br />

Supelco Ascentis ® RP-Amide AC<br />

0.843<br />

Merck Purospher ® RP-18 C A<br />

0.841<br />

Supelco Discovery BIO Wide pore C8 C A<br />

0.839<br />

<strong>Grace</strong> (Grom) Grom Sapphire 110 C8 C A<br />

0.835<br />

Thermo/Hypersil Hypersil ® Beta Basic-8 C A<br />

0.834<br />

<strong>Grace</strong> (Alltech) Alltima HP C8 C A<br />

0.834<br />

Thermo/Hypersil Hypurity ® C8 C A<br />

0.833<br />

Supelco Discovery C8 C A<br />

0.832<br />

GL Sciences Inertsil ® C8-3 C8 C A<br />

0.830<br />

MacMod/ACT ACE ® 5 C8 C A<br />

0.830<br />

<strong>Grace</strong> (Jones) Genesis ® 120 C8 C A<br />

0.829<br />

Thermo Hypersil ® GOLD C8 C A<br />

0.825<br />

Phenomenex Onyx Monolithic C8 C A<br />

0.824<br />

Tosoh TSKgel ® Super-Octyl C A<br />

0.824<br />

<strong>Grace</strong> (Alltech) Prevail Select C18 AC<br />

0.822<br />

Thermo/Hypersil Hypersil ® Bio Basic-8 C<br />

0.821<br />

YMC YMC ® Basic C18 C A<br />

0.821<br />

<strong>Grace</strong> (Alltech) Econosphere C18 A C<br />

0.818<br />

Tosoh TSKgel ® Octyl-80Ts AC<br />

0.814<br />

Whatman Partisil ODS(3) AC<br />

0.810<br />

A<br />

AC<br />

Macherey Nagel Nucleodur ® Sphinx RP AC<br />

0.805<br />

Thermo/Hypersil Aquasil C18 C A<br />

0.805<br />

MacMod/ACT ACE ® AQ EP C A<br />

0.804<br />

Waters Xterra ® MS C8 C A<br />

0.803<br />

Phenomenex Luna C5 C A<br />

0.800<br />

Waters MicroBondapak C18 AC<br />

0.798<br />

Agilent Zorbax StableBond 80A C8 0.795<br />

C A<br />

Agilent Zorbax Rx-C8 0.792<br />

C A<br />

<strong>Grace</strong> (Alltech) Platinum C18 AC<br />

0.786<br />

<strong>Grace</strong> VisionHT C18 AC<br />

0.786<br />

Phenomenex Luna Phenyl-Hexyl AC<br />

0.782<br />

<strong>Grace</strong> (Alltech) Alltima C18-LL C A<br />

0.780<br />

Bischoff ProntoSIL 120-5-C18 ace-EPS A C<br />

0.772<br />

<strong>Grace</strong> (Vydac) Vydac ® 218MS C18 AC<br />

0.770<br />

Waters Acquity UPLC ® BEH phenyl 0.764<br />

C A<br />

Waters Spherisorb ® C8 AC<br />

0.763<br />

YMC J’Sphere ® L80 C18 0.762<br />

C A<br />

Bischoff ProntoSIL 300-55-C18 ace-EPS A C<br />

0.762<br />

Dionex Acclaim ® Organic Acid C18 AC<br />

0.761<br />

Waters Xterra ® C18 RP 0.757<br />

C A<br />

<strong>Grace</strong> (Alltech) Alltima C8 0.756<br />

C A<br />

Whatman Partisil C8 0.749<br />

C A<br />

Merck LiChrospher ® 60 RP-Select B C18 AC<br />

0.747<br />

Bischoff ProntoSIL 120-5 C8 SH C A<br />

0.739<br />

<strong>Grace</strong> (Alltech) Allsphere ODS1 C A<br />

0.733<br />

Waters Symmetry ® Shield C8 A C<br />

0.730<br />

Thermo/Hypersil Hypurity ® C4 0.713<br />

CA<br />

MacMod/ACT ACE ® 5 C4-300 C A<br />

0.710<br />

Varian Polaris ® C8-Ether AC<br />

0.705<br />

Bischoff ProntoSIL 60-5-Phenyl A C<br />

0.705<br />

Waters Nova-Pak ® Phenyl A C<br />

0.704<br />

Macherey Nagel Nucleosil ® 100-5-C18 Nautilus A C<br />

0.702<br />

Agilent Zorbax StableBond 300A C8 0.701<br />

CA<br />

Bischoff ProntoSIL SpheriBOND 80-5-ODS1 A C 0.700<br />

Thermo/Hypersil Fluophase ® RP F AC<br />

0.698<br />

Phenomenex Jupiter ® 300 C4 AC<br />

0.698<br />

<strong>Grace</strong> (Alltech) Prosphere 300 C4 0.689<br />

CA<br />

Bischoff Prontosil 60-5-C4 AC<br />

0.686<br />

Waters Xterra ® Phenyl 0.683<br />

C A<br />

Waters Spherisorb ® ODS-1 C A<br />

0.682<br />

Thermo/Hypersil Hypersil ® Prism C18 RPN 0.678<br />

C A<br />

Thermo/Hypersil Fluophase ® PFP F A C<br />

0.675<br />

Agilent Zorbax XDB-Phenyl AC<br />

0.665<br />

Waters Symmetry ® 300 C4 AC<br />

0.659<br />

Waters Xterra ® C8 RP AC<br />

0.657<br />

<strong>Grace</strong> (Alltech) Alltima HP C18 EPS C A 0.655<br />

Supelco Discovery BIO Wide pore C5 0.654<br />

CA<br />

Agilent Zorbax Bonus RP EP A C<br />

0.654<br />

Phenomenex Synergi Polar-RP C18 AC<br />

0.654<br />

MacMod/ACT ACE ® Phenyl AC<br />

0.647<br />

<strong>Grace</strong> (Jones) Genesis ® 120 C4 EC AC<br />

0.646<br />

Thermo/Hypersil Hypersil ® Prism C18 RP C A<br />

0.645<br />

Thermo/Hypersil BetaMax ® Acid EP 0.635<br />

C A<br />

Supelco Discovery HS F5 F A C<br />

0.631<br />

Agilent Zorbax SB-Phenyl AC<br />

0.623<br />

<strong>Grace</strong> (Alltech) Platinum EPS C18 AC 0.619<br />

<strong>Grace</strong> VisionHT C18-P AC 0.619<br />

<strong>Grace</strong> (Alltech) Prevail C8 AC<br />

0.617<br />

<strong>Grace</strong> (Jones) Genesis ® 300 C4 C4 AC<br />

0.615<br />

<strong>Grace</strong> (Jones) Genesis ® Phenyl A C<br />

0.609<br />

Agilent Zorbax StableBond 80A C3 AC<br />

0.601<br />

MacMod/ACT ACE ® Phenyl-300 AC<br />

0.599<br />

Agilent Zorbax SB-AQ EP AC<br />

0.593<br />

ZirChrom ZirChrom ® -PS EP A<br />

C 0.589<br />

Waters MicroBondapak Phenyl A C<br />

0.585<br />

<strong>Grace</strong> (Alltech) Platinum C8 0.584<br />

CA<br />

<strong>Grace</strong> (Alltech) Platinum EPS C8 300 A C<br />

0.584<br />

Thermo/Hypersil BetaBasic ® Phenyl A C<br />

0.582<br />

Macherey Nagel Nucleosil ® C8 AC 0.575<br />

Macherey Nagel EC Nucleosil ® 100-5 Protect 1 EP C A<br />

0.544<br />

Bischoff Prontosil 120-5-C8 ace-EPS A C<br />

0.532<br />

Phenomenex Prodigy Phenyl-3 A C 0.529<br />

Agilent Zorbax StableBond 300A C3 0.526<br />

C A<br />

<strong>Grace</strong> (Alltech) Alltima HP C18 Amide C A 0.497<br />

Thermo/Hypersil BetaMax ® Base EP A C 0.470<br />

<strong>Grace</strong> (Alltech) Platinum EPS C8 AC 0.420<br />

Thermo/Hypersil Hypurity ® Advance AC 0.412<br />

References:<br />

1. “The “Hydrophobic-subtraction” Model of Reversed-phase Column Selectivity”, L.R. Snyder, J.W. Dolan and P.W. Carr, J. Chromatogr. A, 1060 (2004) 77-116.<br />

2. “A New Look at the Selectivity of Reversed-phase HPLC Columns”, L.R. Snyder, J.W. Dolan and P.W. Carr, Anal. Chem., 79 (2007) 3255-3262.<br />

hplc columns | introduction<br />

www.discoverysciences.com 27


analytical hplc<br />

hplc columns | introduction<br />

28<br />

<strong>Grace</strong> ® HPLC Packing Material Specifications<br />

Columns for Small Molecules<br />

Base<br />

Material<br />

Particle<br />

Shape Particle Size Pore Size Surface Area<br />

Carbon<br />

Load<br />

Endcapped?<br />

USP<br />

L-code<br />

Brand<br />

Phase<br />

Phase Type<br />

Adsorbosil ® C18 Silica Irregular 5, 10µm 60Å 450m 2 /g 15% Polymeric Yes L1<br />

C8 Silica Irregular 5, 10µm 60Å 450m 2 /g 10% Polymeric Yes L7<br />

C2 Silica Irregular 5, 10µm 60Å 450m 2 /g No Polymeric No L16<br />

CN Silica Irregular 5, 10µm 60Å 450m 2 /g — Polymeric Yes L10<br />

NH2 Silica Irregular 5, 10µm 60Å 450m 2 /g — Polymeric No L8<br />

Silica Silica Irregular 5, 10µm 60Å 450m 2 /g — Polymeric No L3<br />

Adsorbosphere C18 Silica Spherical 3, 5, 10µm 80Å 200m 2 /g 12% Monomeric Yes L1<br />

C18 HS Silica Spherical 3, 5µm 60Å 350m 2 /g 20% Monomeric Yes L1<br />

C18 UHS Silica Spherical 5, 10µm 60Å 500m 2 /g 30% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5, 10µm 80Å 200m 2 /g 8% Monomeric Yes L7<br />

Phenyl Silica Spherical 5µm 80Å 200m 2 /g 5% Monomeric Yes L11<br />

Cyano Silica Spherical 5µm 80Å 200m 2 /g — Monomeric Yes L10<br />

Cyano-AQ Silica Spherical 5µm 120Å 170m 2 /g — Polymeric No L10<br />

Amino (NH2) Silica Spherical 3, 5µm 80Å 200m 2 /g — Polymeric No L8<br />

Silica Silica Spherical 5µm 80Å 200m 2 /g — — No L3<br />

SAX Silica Spherical 5µm 80Å 200m 2 /g — Monomeric No —<br />

SCX Silica Spherical 5µm 80Å 200m 2 /g — Monomeric Yes —<br />

Adsorbosphere XL C18 Silica Spherical 3, 5µm 90Å 200m 2 /g 11% Monomeric Yes L1<br />

C18-B Silica Spherical 5µm 90Å 200m 2 /g 12% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5µm 90Å 200m 2 /g 6% Monomeric Yes L7<br />

C1 (TMS) Silica Spherical 5µm 90Å 200m 2 /g — Monomeric Yes L13<br />

Silica Silica Spherical 5µm 90Å 200m 2 /g — — No L3<br />

SAX Silica Spherical 5, 10µm 90Å 200m 2 /g — Monomeric Yes —<br />

SCX Silica Spherical 5, 10µm 90Å 200m 2 /g — Monomeric Yes —<br />

Allsphere ODS-1 Silica Spherical 5µm 80Å 220m 2 /g 7% Monomeric Partial L1<br />

ODS-2 Silica Spherical 3, 5µm 80Å 220m 2 /g 12% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5µm 80Å 220m 2 /g 6% Monomeric Yes L7<br />

C6 Silica Spherical 5µm 80Å 220m 2 /g 4% Monomeric Yes L15<br />

C1 (TMS) Silica Spherical 5µm 80Å 220m 2 /g 3% Monomeric No L13<br />

Phenyl Silica Spherical 5µm 80Å 220m 2 /g 3% Monomeric Yes L11<br />

Cyano Silica Spherical 5µm 80Å 220m 2 /g 3.5% Monomeric No L10<br />

Amino (NH2) Silica Spherical 5µm 80Å 220m 2 /g 3% Monomeric No L8<br />

Silica Silica Spherical 3, 5µm 80Å 220m 2 /g — — No L3<br />

SAX Silica Spherical 5µm 100Å 220m 2 /g 4% Monomeric No —<br />

SCX Silica Spherical 5µm 100Å 220m 2 /g 4% Monomeric No —<br />

Alltima HP C18 Silica Spherical 3, 5µm 190Å 200m 2 /g 12% Monomeric Yes L1<br />

C18 EPS Silica Spherical 3, 5µm 190Å 200m 2 /g 4% Monomeric No L1<br />

C18 HiLoad Silica Spherical 3, 5µm 100Å 450m 2 /g 24% Monomeric Yes L1<br />

C18 AQ Silica Spherical 3, 5µm 100Å 450m 2 /g 20% Monomeric Yes L1<br />

C18 Amide Silica Spherical 3, 5µm 190Å 200m 2 /g 12% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5µm 190Å 200m 2 /g 8% Monomeric Yes L7<br />

Cyano Silica Spherical 3, 5µm 190Å 200m 2 /g 4% Monomeric Yes L10<br />

Silica Silica Spherical 3, 5µm 100Å 450m 2 /g — — No L3<br />

HILIC Silica Spherical 1.5, 3, 5µm 120Å 230m 2 /g — — No L3<br />

Alltima C18 Silica Spherical 3, 5, 10µm 100Å 340m 2 /g 16% Polymeric Yes L1<br />

C18 LL Silica Spherical 5µm 100Å 340m 2 /g 9% Polymeric Yes L1<br />

C8 Silica Spherical 3, 5, 10µm 100Å 340m 2 /g 9% Polymeric Yes L7<br />

Phenyl Silica Spherical 3, 5µm 100Å 340m 2 /g 7.5% Polymeric Yes L11<br />

Cyano Silica Spherical 3, 5µm 100Å 340m 2 /g — Polymeric Yes L10<br />

Amino (NH2) Silica Spherical 3, 5µm 100Å 340m 2 /g — Polymeric No L8<br />

Silica Silica Spherical 3, 5, 10µm 100Å 340m 2 /g — — No L3<br />

AlphaBond C18 Silica Irregular 5, 10µm 125Å 300m 2 /g 10% Monomeric Yes L1<br />

C8 Silica Irregular 10µm 125Å 300m 2 /g — Monomeric Yes L7<br />

Phenyl Silica Irregular 10µm 125Å 300m 2 /g — Monomeric Yes L11<br />

Cyano Silica Irregular 10µm 125Å 300m 2 /g — Monomeric Yes L10<br />

Amino (NH2) Silica Irregular 10µm 125Å 300m 2 /g — Polymeric No L8<br />

Silica Silica Irregular 10µm 125Å 300m 2 /g — — No L3<br />

Apex I ODS Silica Spherical 3, 5, 10µm 100Å 170m 2 /g 10% Polymeric Yes L1<br />

C8 Silica Spherical 3, 5µm 100Å 170m 2 /g 7% Monomeric No L7<br />

C8(EC) Silica Spherical 3, 5µm 100Å 170m 2 /g 7% Monomeric Yes L7<br />

C1 Silica Spherical 3, 5µm 100Å 170m 2 /g 2.5% Monomeric Yes L13<br />

Phe Silica Spherical 3, 5µm 100Å 170m 2 /g 3% Monomeric No L11<br />

Basic ODS Silica Spherical 5µm 100Å 200m 2 /g 12% Monomeric Yes L1<br />

PAH Silica Spherical 5µm 100Å 170m 2 /g — Monomeric Yes<br />

CN Silica Spherical 3, 5µm 100Å 170m 2 /g 4% Monomeric No L10<br />

Amino (NH2) Silica Spherical 3, 5µm 100Å 170m 2 /g 2% Monomeric No L8<br />

Carbohydrate Silica Spherical 5µm 100Å 170m 2 /g — Monomeric †<br />

Silica Silica Spherical 3, 5, 10µm 100Å 170m 2 /g — — No L3<br />

Apex II ODS Silica Spherical 3, 5µm 100Å 170m 2 /g 10.5% Monomeric Yes L1<br />

Diol Silica Spherical 3, 5µm 100Å 170m 2 /g 3.5% Monomeric No<br />

Amino (NH2) Silica Spherical 3, 5µm 100Å 170m 2 /g 2% Monomeric No L8<br />

Others—as Apex I Silica Spherical 5µm 100Å 170m 2 /g — — No —<br />

Apex Prepsil ODS Silica Spherical 8, 15µm 130Å 170m 2 /g 10% Polymeric Yes L1<br />

C8 Silica Spherical 8, 15µm 130Å 170m 2 /g 7% Monomeric No L7<br />

C8(EC) Silica Spherical 8, 15µm 130Å 170m 2 /g 7% Monomeric Yes L7<br />

C2 Silica Spherical 8µm 130Å 170m 2 /g 2.8% Monomeric No L30<br />

CN Silica Spherical 8µm 130Å 170m 2 /g 4% Monomeric Yes L10<br />

Amino (NH2) Silica Spherical 8µm 130Å 170m 2 /g 2% Monomeric Yes L8<br />

Silica Silica Spherical 8, 15µm 130Å 170m 2 /g — — No L3<br />

Diol Silica Spherical 8µm 130Å 170m 2 /g 3.2% Monomeric No L20<br />

†Proprietary.<br />

www.discoverysciences.com


analytical hplc<br />

Columns for Small Molecules (continued)<br />

Base<br />

Material<br />

Particle<br />

Shape Particle Size Pore Size Surface Area<br />

Carbon<br />

Load<br />

Endcapped?<br />

USP<br />

L-code<br />

Brand<br />

Phase<br />

Phase Type<br />

Apollo C18 Silica Spherical 5µm 100Å 340m 2 /g 15% Monomeric Yes L1<br />

C8 Silica Spherical 5µm 100Å 340m 2 /g 9% Monomeric Yes L7<br />

Phenyl Silica Spherical 5µm 100Å 340m 2 /g 8% Monomeric Yes L11<br />

Silica Silica Spherical 5µm 100Å 340m 2 /g — — No L3<br />

Brava C18 BDS Silica Spherical 3, 5µm 145Å 185m 2 /g 8.5% Monomeric Yes L1<br />

C18 ODS Silica Spherical 3, 5µm 130Å 195m 2 /g 8.5% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5µm 130Å 195m 2 /g 6% Monomeric Yes L7<br />

C8 BDS Silica Spherical 3, 5µm 145Å 185m 2 /g 5.5% Monomeric Yes L7<br />

Phenyl Silica Spherical 5µm 130Å 195m 2 /g — Monomeric No L11<br />

Cyano Silica Spherical 5µm 130Å 195m 2 /g — Monomeric No L10<br />

Cyano BDS Silica Spherical 5µm 145Å 185m 2 /g — Monomeric No L10<br />

Amino (NH2) Silica Spherical 5µm 130Å 195m 2 /g — Monomeric No L8<br />

Silica Silica Spherical 5µm 130Å 195m 2 /g — — No L3<br />

Carbohydrate Amino Silica Irregular 10µm 80Å 550m 2 /g — Polymeric No —<br />

Cation Polymer Spherical 10µm — — — — No —<br />

Denali ® 238DE C18 Silica Spherical 3, 5, 10, 15, 20µm 120Å 280-340m 2 /g 20% Monomeric Yes L1<br />

Econosil* C18 Silica Irregular 3, 5, 10µm 80Å 200m 2 /g 10% Monomeric Yes L1<br />

C8 Silica Irregular 3, 5, 10µm 80Å 200m 2 /g 5% Monomeric Yes L7<br />

CN Silica Irregular 5, 10µm 80Å 200m 2 /g — Monomeric Yes L10<br />

NH2 Silica Irregular 5, 10µm 80Å 200m 2 /g — Polymeric No L8<br />

Silica Silica Irregular 3, 5, 10µm 80Å 200m 2 /g — — No L3<br />

Econosphere* C18 Silica Spherical 3, 5, 10µm 80Å 200m 2 /g 10% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5, 10µm 80Å 200m 2 /g 5% Monomeric Yes L7<br />

Cyano Silica Spherical 5µm 80Å 200m 2 /g — Monomeric Yes L10<br />

Amino (NH2) Silica Spherical 5µm 80Å 200m 2 /g — Polymeric No L8<br />

Silica Silica Spherical 3, 5, 10µm 80Å 200m 2 /g — — No L3<br />

Genesis ® 120 C18 Silica Spherical 3, 4, 7, 15µm 120Å 300m 2 /g 18% Monomeric Yes L1<br />

C18 AQ Silica Spherical 4, 7µm 120Å 300m 2 /g 15% Monomeric Yes L1<br />

C8 Silica Spherical 3, 4, 7, 15µm 120Å 300m 2 /g 11% Monomeric No L7<br />

C8(EC) Silica Spherical 3, 4, 7, 15µm 120Å 300m 2 /g 11% Monomeric Yes L7<br />

C4 Silica Spherical 4µm 120Å 300m 2 /g 6% Monomeric Yes L26<br />

Phenyl Silica Spherical 4µm 120Å 300m 2 /g 9% Monomeric Yes L11<br />

CN Silica Spherical 3, 4µm 120Å 300m 2 /g 7% Monomeric Yes L10<br />

Amino (NH2) Silica Spherical 3, 4µm 120Å 300m 2 /g 3.5% Polymeric No L8<br />

Carbohydrate Silica Spherical 4µm 120Å 300m 2 /g — Monomeric No —<br />

CN-TCA Silica Spherical 4µm 120Å 300m 2 /g 7% Monomeric Yes —<br />

Petro-XP Silica Spherical 4µm 120Å 300m 2 /g — Monomeric No —<br />

Silica Silica Spherical 3, 4, 7, 15µm 120Å 300m 2 /g — — No L3<br />

<strong>Grace</strong> Alpha ® C18 Silica Spherical 5, 10, 15, 20µm 120Å 325m 2 /g 15% Monomeric Yes L1<br />

C8 Silica Spherical 5, 10, 15, 20µm 120Å 325m 2 /g 10% Monomeric No L7<br />

Silica Silica Spherical 5, 10, 15, 20µm 120Å 325m 2 /g — — No L3<br />

<strong>Grace</strong>Smart C18 Silica Spherical 3, 5µm 120Å 220m 2 /g 10% Monomeric Yes L1<br />

Grom Sil ODS-0 AB (acid/base deactivated) Silica Spherical 1.5, 3, 5, 10µm 100Å 200m 2 /g 11% Monomeric Yes L1<br />

ODS-2 FE (fully endcapped) Silica Spherical 1.5, 3, 5, 10µm 80, 100, 300Å 220, 200, 100m 2 /g 12, 11, 6% Monomeric Yes L1<br />

ODS-3 CP (encapsulated) Silica Spherical 3, 5, 7, 10µm 120, 300Å 320, 170m 2 /g 15, 6% Polymeric No L1<br />

ODS-4 HE (hydrophilic endcapping) Silica Spherical 3, 4, 5, 7, 10µm 120, 200Å 300, 200m 2 /g 16, 11% Monomeric Yes L1<br />

ODS-5 ST (standard) Silica Spherical 3, 4, 5, 7, 10µm 60, 120, 200, 300Å 580, 300, 200, 22, 17, Monomeric Yes L1<br />

150m 2 /g<br />

12, 7%<br />

ODS-6 NE (non endcapped) Silica Irregular 3, 5µm 120Å 300m 2 /g 17% Monomeric No L1<br />

ODS-7 pH (pH-stable) Silica Irregular 4µm 80Å 510m 2 /g 22% Polymeric No L1<br />

Octyl-1 B (base deactivated) Silica Spherical 3, 5µm 100Å 200m 2 /g 6.5% Monomeric Yes L7<br />

Octyl-2 AB (acid/base deactivated) Silica Spherical 3, 5µm 100Å 200m 2 /g 5% Monomeric Yes L7<br />

Octyl-3 BA (for bases) Silica Spherical 3, 5µm 120Å 300m 2 /g 9% Monomeric Yes L7<br />

Octyl-4 FE (fully endcapped) Silica Spherical 3, 5, 10µm 80, 100, 300Å 220, 200, 100m 2 /g 6.6, 6, 3% Monomeric Yes L7<br />

Octyl-5 CP (encapsulated) Silica Spherical 3, 5, 7, 10µm 120, 300Å 320, 170m 2 /g 10, 5.5% Polymeric No L7<br />

Octyl-6 MB (monomer binding) Silica Spherical 3, 5, 10µm 120, 200, 300Å 300, 200, 150m 2 /g 10, 7, 4% Monomeric Yes L7<br />

Hexyl-1 MB (monomeric bonding) Silica Spherical 5µm 80, 100Å 220, 200m 2 /g 4, 4% Monomeric Yes<br />

Phenyl-1 FE (fully endcapped) Silica Spherical 3, 5, 10µm 120, 300Å 300, 150m 2 /g 9, 5% Monomeric Yes L11<br />

Phenyl-2 CP (encapsulated) Silica Irregular 5µm 120, 300Å 320, 170m 2 /g 7, 4% Polymeric No L11<br />

Phenyl-3 PE (partially endcapped) Silica Spherical 3, 5, 10µm 80, 100Å 220, 200m 2 /g 6.6, 6% Monomeric Yes L11<br />

Butyl-1 ST (standard) Silica Spherical 3, 5µm 120, 300Å 300, 150m 2 /g 7, 2.5% Monomeric No L26<br />

Butyl-2 FE (fully endcapped) Silica Spherical 3, 5µm 300Å 100m 2 /g 1, 5% Monomeric No L26<br />

TMS-1 ST (standard) Silica Spherical 3, 5µm 120, 300Å 300, 150m 2 /g 4% Monomeric Yes L13<br />

TMS-2 CP (encapsulated) Silica Spherical 3, 5µm 120, 300Å 320, 170m 2 /g 3% Polymeric No L13<br />

Cyan-1 ST (standard) Silica Spherical 3, 5µm 120, 300Å 300, 150m 2 /g 4.8% Monomeric Yes<br />

Cyan-2 PR (cyanopropyl) Silica Spherical 3, 5µm 80, 100Å 220, 200m 2 /g 3.5% Monomeric Yes<br />

Cyan-3 CP (encapsulated) Silica Spherical 5µm 120Å 320m 2 /g 4% Polymeric No<br />

Amino-1 PR (NH-propyl) Silica Spherical 3, 5, 10µm 80, 100Å 220, 200m 2 /g 2% Monomeric Yes L8<br />

Amino-2 PA (cross linked Poly-NH2) Silica Spherical 5µm 120Å 300m 2 /g — Polymeric No L8<br />

Amino-3 CP (encapsulated NH-residues) Silica Irregular 5µm 80Å 420m 2 /g — Monomeric Yes L8<br />

Amino-4 PR (propylamine bonded Silica Irregular 3, 7µm 300Å 100m 2 /g — Monomeric No L8<br />

to silica)<br />

Diol Silica Spherical 5, 10µm 60, 120, 200, 300Å 580, 300, 200, — Monomeric No L20<br />

150m 2 /g<br />

Normal Phase-1 ST (standard silica) Silica Spherical 3, 5, 10µm 80, 100, 1000Å 220, 200m 2 /g — — No L3<br />

Normal Phase-2 SP (spherical silica) Silica Spherical 3, 5, 10µm 60, 120, 200, 580, 300, 200m 2 /g — — No L3<br />

1000Å<br />

Normal Phase-3 PV (polyvinylalcohol) Silica Spherical 5µm 120Å 300m 2 /g — Polymeric No L3<br />

SEC (size exclusion chromatography) Silica Spherical 5, 10µm 60, 120, 200, 300Å 580, 300, 200, — — No<br />

150m 2 /g<br />

Strong Anion-1 Silica Spherical 5, 10µm 80, 100Å 220, 200m 2 /g — — No<br />

Weak Anion-2 (ion exchange) Silica Spherical 7µm 300Å 100m 2 /g — — No<br />

Strong Cation-1 (ion exchange) Silica Spherical 5, 10µm 80, 100Å 220, 200m 2 /g — — No<br />

*Available only online.<br />

hplc columns | introduction<br />

www.discoverysciences.com 29


analytical hplc<br />

hplc columns | introduction<br />

Columns for Small Molecules (continued)<br />

Base<br />

Material<br />

Particle<br />

Shape Particle Size Pore Size Surface Area<br />

Carbon<br />

Load<br />

Endcapped?<br />

USP<br />

L-code<br />

Brand<br />

Phase<br />

Phase Type<br />

Grom Sil (cont.) Weak Cation-2 (ion exchange) Silica Spherical 7µm 300Å 100m 2 /g — — No<br />

HIC (hydrophobic interaction chrom.) Silica Spherical 7µm 300Å 100m 2 /g — — No<br />

Grom Sapphire C18 Silica Spherical 3, 5, 10µm 65, 110Å 500, 270m 2 /g 23, 16% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5, 10µm 65, 110Å 500, 270m 2 /g 15, 10% Monomeric Yes L7<br />

C4 Silica Spherical 3, 5, 10µm 65, 110Å 500, 270m 2 /g 10.5, 7% Monomeric Yes L26<br />

Silica Silica Spherical 3, 5, 10µm 65, 110Å 500, 270m 2 /g — — No L3<br />

Mixed Mode C18/Cation Silica Spherical 5, 7µm 100Å 350m 2 /g — Polymeric No —<br />

C8/Anion Silica Spherical 7µm 100Å 350m 2 /g — Polymeric No —<br />

C8/Cation Silica Spherical 5µm 100Å 350m 2 /g — Polymeric No —<br />

Platinum C18 Silica Spherical 1.5, 3, 5µm 100Å 200m 2 /g 6% Monomeric Yes L1<br />

C18 EPS Silica Spherical 1.5, 3, 5µm 100Å 200m 2 /g 5% Monomeric No L1<br />

C8 Silica Spherical 1.5, 3, 5µm 100Å 200m 2 /g 4% Monomeric Yes L7<br />

C8 EPS Silica Spherical 3, 5µm 100Å 200m 2 /g 2.5% Monomeric No L7<br />

Phenyl Silica Spherical 3, 5µm 100Å 200m 2 /g — Monomeric Yes L11<br />

Cyano Silica Spherical 3, 5µm 100Å 200m 2 /g — Monomeric No L10<br />

Amino (NH2) Silica Spherical 3, 5µm 100Å 200m 2 /g — Monomeric No L8<br />

Silica Silica Spherical 3, 5µm 100Å 200m 2 /g — — No L3<br />

SAX Silica Spherical 3, 5µm 100Å 200m 2 /g — Monomeric No —<br />

Prevail C18 Select Silica Spherical 3, 5µm 110Å 350m 2 /g 17% Monomeric Yes L1<br />

C18 Silica Spherical 3, 5µm 110Å 350m 2 /g 15% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5µm 110Å 350m 2 /g 8% Monomeric Yes L7<br />

Phenyl Silica Spherical 3, 5µm 110Å 350m 2 /g 7% Monomeric Yes L11<br />

Cyano Silica Spherical 3, 5µm 110Å 350m 2 /g — Monomeric Yes L10<br />

Amino (NH2) Silica Spherical 3, 5µm 110Å 350m 2 /g — Monomeric No L8<br />

Silica Silica Spherical 3, 5µm 110Å 350m 2 /g — — No L3<br />

Organic Acid Silica Spherical 3, 5µm 110Å 350m 2 /g — Monomeric Yes —<br />

Carbohydrate ES Polymer Spherical 5µm — — — — No —<br />

Vydac ® SP 101SP Sil Silica Spheroidal 5, 10µm 100Å 250–350m 2 /g — unbonded No L3<br />

201SP C18 Silica Spheroidal 3, 5, 10, 15µm 90Å 250–350m 2 /g 13% Monomeric Yes L1<br />

208SP C8 Silica Spheroidal 5, 10, 15µm 90Å 250–350m 2 /g 9% Monomeric Yes L7<br />

VisionHT C18 Silica Spherical 1.5µm 100Å 200m 2 /g 6% Monomeric Yes L1<br />

C-18-B Silica Spherical 1.5µm 120Å 220m 2 /g 5.5% Monomeric † L1<br />

C18-P Silica Spherical 1.5µm 100Å 200m 2 /g 5% Monomeric No L1<br />

C18-HL Silica Spherical 1.5µm 120Å 220m 2 /g 11% Polymeric † L1<br />

HILIC, Silica Silica Spherical 1.5µm 120Å 220m 2 /g — — No L3<br />

Columns for Large Molecules<br />

Base<br />

Material<br />

Particle<br />

Shape Particle Size Pore Size Surface Area<br />

Carbon<br />

Load<br />

Endcapped?<br />

USP<br />

L-code<br />

Brand<br />

Phase<br />

Phase Type<br />

Genesis ® 300 C18 Silica Spherical 4, 7µm 300Å 120m 2 /g 10% Monomeric Yes L1<br />

C4 Silica Spherical 4, 7µm 300Å 120m 2 /g 3% Monomeric Yes L26<br />

CN Silica Spherical 4µm 300Å 120m 2 /g 3.3% Monomeric Yes L11<br />

Macrosphere 300 C18 Silica Spherical 5, 7µm 300Å 100m 2 /g 10% Monomeric Yes L1<br />

C8 Silica Spherical 5, 7µm 300Å 100m 2 /g 2.2% Monomeric Yes L7<br />

C4 Silica Spherical 5, 7µm 300Å 100m 2 /g — Monomeric Yes L26<br />

SAX Silica Spherical 7µm 300Å 100m 2 /g — Monomeric No —<br />

WAX Silica Spherical 7µm 300Å 100m 2 /g — Monomeric No —<br />

SCX Silica Spherical 7µm 300Å 100m 2 /g — Polymeric No —<br />

WCX Silica Spherical 7µm 300Å 100m 2 /g — Polymeric No —<br />

Macrosphere GPC GPC 60 Silica Spherical 7µm 60Å 450m 2 /g — Polymeric No L25<br />

GPC 100 Silica Spherical 7µm 100Å 350m 2 /g — Polymeric No —<br />

GPC 150 Silica Spherical 7µm 150Å 200m 2 /g — Polymeric No —<br />

GPC 300 Silica Spherical 7µm 300Å 100m 2 /g — Polymeric No —<br />

ProSphere C18 Silica Spherical 3, 5, 10µm 300Å 120m 2 /g 9% Monomeric Yes L1<br />

C18-AQ Silica Spherical 3, 5µm 100Å 450m 2 /g 18% Monomeric Yes L1<br />

C4 Silica Spherical 3, 5, 10µm 300Å 120m 2 /g 3% Monomeric Yes L26<br />

Size-Exclusion 125 Silica Spherical 4, 5µm 125Å — — — No —<br />

Size-Exclusion 250 Silica Spherical 4, 5µm 250Å — — — No —<br />

Size-Exclusion 450 Silica Spherical 8µm 450Å — — — No —<br />

P-HR (reversed phase) Polymer Spherical 4µm 140Å — — — No —<br />

ProZap C18 ProZap Silica Spherical 1.5µm 500Å 59m 2 /g 3% Monomeric Yes L1<br />

Vydac ® ATP 214ATP C4 Silica Spheroidal 5, 10–15µm 300Å 70–110m 2 /g 3% Polymeric Yes L26<br />

Vydac ® TP 101TP Sil Silica Spheroidal 5, 10, 10–15, 15–20µm 300Å 70–110m 2 /g — unbonded No L3<br />

201TP C18 Silica Spheroidal 5, 7, 10, 10–15, 300Å 70–90m 2 /g 8% Polymeric No L1<br />

15–20µm<br />

202TP C18 Silica Spheroidal 3, 5, 10µm 300Å 60–90m 2 /g 9% Polymeric No L1<br />

208TP C8 Silica Spheroidal 3, 5, 7, 10, 10–15, 300Å 60–110m 2 /g 5% Polymeric Yes L7<br />

15–20µm<br />

214TP C4 Silica Spheroidal 3, 5, 7, 10, 10–15, 300Å 60–110m 2 /g 3% Polymeric Yes L26<br />

15–20µm<br />

218TP C18 Silica Spheroidal 3, 5, 7, 10, 10–15, 300Å 60–110m 2 /g 8% Polymeric Yes L1<br />

15–20µm<br />

219TP Di-Phe Silica Spheroidal 3, 5, 7, 10, 10–15, 300Å 60–110m 2 /g 4% Polymeric Yes<br />

15–20µm<br />

238TP C18 Silica Spheroidal 3, 5, 7, 10, 10–15, 300Å 60–110m 2 /g 4% Monomeric Yes L1<br />

15–20µm<br />

Everest ® 238EV C18 Silica Spherical 5, 10, 10–15, 15–20µm 300Å 70–110m 2 /g 6% Monomeric Yes L1<br />

Vydac ® MS 208MS C8 Silica Spheroidal 5µm 300Å 70m 2 /g 5% Polymeric Yes L7<br />

214MS C4 Silica Spheroidal 5µm 300Å 70–110m 2 /g 3% Polymeric Yes L26<br />

218MS C18 Silica Spheroidal 3, 5, 10, 10–15µm 300Å 60–110m 2 /g 8% Polymeric Yes L1<br />

238MS C18 Silica Spheroidal 5µm 300Å 70m 2 /g 4% Monomeric Yes L1<br />

219MS Di-Phe Silica Spheroidal 5µm 300Å 70m 2 /g 4% Polymeric Yes<br />

*Product information is available at www.discoverysciences.com. †Proprietary.<br />

30<br />

www.discoverysciences.com


analytical hplc<br />

<strong>Grace</strong> ® HPLC Hardware Formats<br />

<strong>Grace</strong> Davison Discovery Sciences provides hardware formats to maximize the performance of the phases in our column families<br />

for all applications. Choose a hardware format based on your method requirements for speed, sensitivity, and resolution.<br />

Ultra High-Pressure Hardware<br />

Analytical Hardware<br />

Ideally suited for ultra high-pressure systems, this ultralow<br />

volume hardware is pressure rated to 18,000psig,<br />

and packed with 1.5µm media to maximize speed and<br />

efficiency.<br />

Lengths<br />

20, 30, 50, 100mm<br />

Expedite MS Hardware<br />

Inner<br />

Pressure Wetted<br />

Diameters Limit<br />

Surfaces<br />

1.0, 2.0mm 18,000psig 316 Stainless Steel<br />

High-speed, low-volume columns for rapid resolution and<br />

high-throughput LC/MS applications.<br />

7135<br />

6113<br />

4.6mm i.d. columns for standard HPLC instrumentation,<br />

the most commonly used. Analytical columns have<br />

industry standard port configurations. Some column<br />

families are also available with port configurations for<br />

Waters ® endfittings.<br />

Lengths<br />

30, 50, 100, 150,<br />

250, 300mm<br />

Metal-Free Hardware<br />

Inner<br />

Pressure Wetted<br />

Diameters Limit<br />

Surfaces<br />

4.6mm 10,000psig 316 Stainless Steel<br />

7345<br />

hplc columns | introduction<br />

Lengths<br />

10, 20mm<br />

Rocket Hardware<br />

Inner<br />

Pressure Wetted<br />

Diameters Limit<br />

Surfaces<br />

2.1, 4.6mm 10,000psig 316 Stainless Steel<br />

High-speed, high-resolution columns for high-throughput<br />

analysis. Large 7mm i.d. balances column volume<br />

with system volume to deliver excellent peak shapes<br />

on conventional HPLC instrumentation. Large i.d. also<br />

allows fast mobile-phase flow rates which minimizes<br />

peak broadening.<br />

Lengths<br />

33, 53mm<br />

Solvent-Reducer and Microbore Hardware<br />

Smaller diameter columns reduce solvent consumption<br />

and increase sensitivity when compared to standard<br />

4.6mm i.d. columns. Use with standard HPLC<br />

instrumentation or with MS and ELS detectors.<br />

Lengths<br />

50, 100, 150, 150,<br />

250, 300mm<br />

Inner<br />

Pressure Wetted<br />

Diameters Limit<br />

Surfaces<br />

7mm 10,000psig 316 Stainless Steel<br />

Inner<br />

Diameters<br />

Pressure<br />

Limit<br />

Wetted<br />

Surfaces<br />

1.0, 2.1, 3.0mm 10,000psig 316 Stainless Steel<br />

7345<br />

6904<br />

Mechanically strong, metal-free columns offer<br />

biocompatibility, and chemical resistance that ion<br />

chromatography and biotechnology applications demand.<br />

Lengths<br />

50, 100, 150, 250,<br />

300mm<br />

Capillary Guards<br />

Inner<br />

Pressure<br />

Diameters Limit<br />

2.1, 4.6mm 5000psig PEEK<br />

All-Guard Guard Cartridges<br />

Wetted<br />

Surfaces<br />

Capillary guards offer zero dead-volume with finger-tight<br />

connections to maintain column performance. Use them<br />

to protective your capillary investment, as enrichment<br />

columns, or as short analytical columns.<br />

Lengths<br />

5, 10, 20mm<br />

Inner<br />

Diameters<br />

Pressure<br />

Limit<br />

Wetted<br />

Surfaces<br />

0.3, 0.5mm 5000psig 316 Stainless Steel<br />

and fused silica<br />

Guard system with reusable holder and disposable guard<br />

columns to protect analytical columns.<br />

6617<br />

7341<br />

6931<br />

Capillary Hardware<br />

Lengths<br />

7.5mm<br />

Inner<br />

Pressure Wetted<br />

Diameters Limit<br />

Surfaces<br />

2.1, 3.0, 4.6mm 5000psig 316 Stainless Steel<br />

7344<br />

For LC/MS and other high-sensitivity and sample-limited<br />

applications.<br />

Lengths<br />

50, 100, 150, 250,<br />

300mm<br />

Inner<br />

Diameters<br />

0.075, 0.150,<br />

0.3, 0.5, 0.8mm<br />

Pressure<br />

Limit<br />

5000psig<br />

Wetted<br />

Surfaces<br />

316 Stainless Steel<br />

and fused silica<br />

more info<br />

Looking for preparative HPLC hardware?<br />

See page 150.<br />

www.discoverysciences.com 31


analytical hplc<br />

hplc columns | introduction<br />

High Throughput HPLC<br />

Introduction<br />

The Benefits of <strong>Grace</strong> ® Small Particles and<br />

Formats<br />

Today’s laboratories are under greater demand to analyze<br />

more samples in less time. To help meet this demand, major<br />

product advances have been made to decrease analysis<br />

time and increase HPLC throughput. HPLC system advances<br />

have greatly reduced the influence of extra column volumes<br />

and have extended the range of flow rates and pressure<br />

capabilities. In response to this, <strong>Grace</strong> now offers a wide<br />

range of column chemistries and formats appropriate for<br />

all types of high throughput systems.<br />

The use of smaller particles offers two main improvements to<br />

the chromatographic separation—increased resolution and<br />

speed. Resolution is directly proportional to the square root<br />

of column efficiency, therefore the higher the efficiency, the<br />

narrower the peaks and the greater the resolution between<br />

them. Increased speed comes from higher mobile phase flow<br />

rates that can be used without loss in efficiency, and higher<br />

flow rates mean faster analysis times.<br />

Understanding the type of system currently in use for<br />

high throughput separations and then matching the right<br />

column configuration is critical to achieving the best high<br />

throughput separation. Here we outline the three types of<br />

systems currently in use today for high throughput and the<br />

recommended HPLC column format for use with that system.<br />

System Type 1<br />

Ultra High-Pressure LC System<br />

(>10,000psig pressure limitation)<br />

Examples: Agilent 1200, Waters ® Acquity ® , Thermo Accela,<br />

Jasco XLc.<br />

Speed from Ultra High-Pressure Systems:<br />

Representing the latest in LC instrumentation technology,<br />

ultra high-pressure systems theoretically have the potential<br />

to deliver the fastest separations. They have minimal system<br />

volume and offer a pressure limit upwards of 12,000psig.<br />

This allows the use of columns with sub 2µm particles and<br />

2–7 times traditional flow rates. Sub 2µm particles extend the<br />

working range of acceptable mobile phase linear velocities<br />

without sacrificing efficiency. Therefore, you can push flow<br />

rates and still get equal or better performance.<br />

Suggested Column Format:<br />

VisionHT columns are designed for microbore and ultra<br />

high-pressure LC systems that have small system volumes<br />

to limit peak broadening from sample diffusion. VisionHT<br />

columns are packed with highly efficient 1.5µm phases<br />

that yield taller peaks and increase sensitivity. The column<br />

hardware incorporates a low dead volume design to minimize<br />

sample diffusion, and maintain peak integrity and efficiency.<br />

12,000psig high-pressure stability allows fast flow rates,<br />

decreasing run times 10 fold.<br />

System Type 1<br />

Recommended Column Format:<br />

Length:<br />

i.d.:<br />

VisionHT<br />

20, 30, 50, 100mm<br />

1.0 and 2.0mm<br />

tech tip<br />

Converting Methods From Traditional Column<br />

Formats to High Throughput Columns<br />

7135<br />

Convert Between Standard HPLC and VisionHT Columns<br />

Flow Rate<br />

Standard HPLC (4.6mm) 1.0X<br />

VisionHT (2.0mm) 2.3X<br />

When adjusting between standard LC conditions to VisionHT<br />

columns convert flow rates accordingly and then increase flow<br />

rate for faster analysis.<br />

Convert Between Standard HPLC Columns and Rocket Columns<br />

Flow Rate<br />

Standard Analytical (4.6mm) 1.0X<br />

Rocket Column (7.0mm) 2.3X<br />

mAU<br />

20<br />

15<br />

10<br />

5<br />

0<br />

VisionHT Columns for<br />

Ultra High-Pressure LC<br />

2<br />

5<br />

1 3 4 6 7<br />

8<br />

10724<br />

1. Sulfadiazine<br />

2. Sulfathiazole<br />

3. Sulfamerazine<br />

4. Sulfamethazine<br />

5. Sulfamethoxazole<br />

6. Sulfaisoxazole<br />

7. Sulfaquinoxilone<br />

8. Sulfamethoxine<br />

Use this conversion of flow rate to transfer methods between<br />

Rocket column or VisionHT columns. Backpressure on<br />

standard LC systems should be considered.<br />

0 1 2 3 4 5 Min.<br />

System Agilent 1200<br />

Mobile Phase: A: 0.1% Formic Acid<br />

B: Methanol<br />

Detector: UV at 280nm<br />

Temperature: Ambient<br />

more info<br />

See pages 34–37 for more information on VisionHT columns.<br />

32<br />

www.discoverysciences.com


analytical hplc<br />

System Type 2<br />

Low Volume, High Throughput (HTP)<br />

LC System<br />

(


0<br />

857<br />

1714<br />

2571<br />

3428<br />

4285<br />

5142<br />

6000<br />

6856<br />

7713<br />

8570<br />

9427<br />

10284<br />

11141<br />

11998<br />

12855<br />

13712<br />

14569<br />

15426<br />

16283<br />

17140<br />

analytical hplc<br />

hplc columns | small molecule<br />

<strong>Grace</strong> ® VisionHT Ultra High-Pressure Columns<br />

See Separations with Speed and Clarity<br />

• Ultra-fast separations with superior efficiency, sensitivity, and resolution<br />

• Exceptional stability for long column lifetimes<br />

• Comprehensive sub 2μm stationary phase offering<br />

• 12,000psig pressure rating compatible with all ultra high-pressure LC systems<br />

<strong>Grace</strong> ® VisionHT columns offer a new level of performance in HPLC. The powerful combination of<br />

high-strength 1.5µm media with ultra-low volume hardware, delivers new clarity to your separations<br />

and maintains exceptional column lifetime. Complex samples resolve 95% faster with 4x greater<br />

sensitivity when compared to traditional 2.1 x 150mm, 5µm columns. And with a wide variety of<br />

phases available, the possibilities are endless.<br />

2500 mAU<br />

2000<br />

1500<br />

1000<br />

500<br />

2500 mAU<br />

0<br />

0<br />

2000<br />

0<br />

0<br />

2<br />

1500<br />

1<br />

3<br />

1000<br />

4<br />

500<br />

1 2<br />

2<br />

3<br />

2 4 6 8 10 12 14 Min.<br />

Increase Speed by 95% and Gain 4x Better Sensitivity<br />

Column: VisionHT C18, 1.5µm,<br />

2.0 x 50mm<br />

Flow Rate: 0.8mL/min<br />

4<br />

2500 mAU<br />

2000<br />

1500<br />

1000<br />

4 6 8 10 12 14 Min.<br />

Column: Traditional C18, 5µm, 2.1 x 150mm<br />

Flow Rate: 0.2mL/min<br />

500<br />

0<br />

1<br />

2<br />

3<br />

4<br />

Impurities<br />

not seen on<br />

traditional<br />

5µm columns.<br />

0 0.5 1 1.5 2 Min.<br />

1. Thiourea<br />

2. Toluene<br />

3. Propylbenzene<br />

4. Butylbenzene<br />

System: Agilent 1200<br />

Mobile Phase: (45:55) 20mM Potassium Phosphate,<br />

pH 2.5:Acetonitrile<br />

Detector: UV at 254nm<br />

Temperature: Ambient<br />

Efficiency and Retention Times Remain Constant after Exposure to 12,000psig and 2000 Injections<br />

Plates/Meter (000)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

Column Stability Comparison, 50 x 2mm<br />

VisionHT Column 1<br />

VisionHT Column 2<br />

VisionHT Column 3<br />

VisionHT Column 4<br />

Column Volumes<br />

VisionHT Column 5<br />

VisionHT Column 6<br />

VisionHT Column 7<br />

Competitor Sub 2µm Column<br />

Competitor<br />

Sub 2µm Column<br />

1<br />

2+3<br />

1<br />

2+3<br />

4<br />

4 6<br />

5<br />

5<br />

0 2 4 6 8 Min.<br />

6<br />

1. Uracil<br />

2. Pyridine<br />

3. Phenol<br />

4. Methyl Alanine<br />

5. 4-Butyl Benzoic Acid<br />

6. Toluene<br />

Initial<br />

FINAL<br />

(After 2000 injections)<br />

0 2 4 6 8 Min.<br />

Column: 2.0 x 50mm<br />

Mobile Phase: 50mM KH2PO4, pH 7.0:CH3CN (60:40)<br />

Flow Rate: 1.0mL/min<br />

High-pressure competitor sub 2µm column lost efficiency at routine<br />

12,000psig pressures. VisionHT columns remain stable.<br />

Before and after chromatograms show a constant level of<br />

performance after 2000 injections.<br />

34<br />

www.discoverysciences.com


analytical hplc<br />

<strong>Grace</strong> ® VisionHT Ultra High-Pressure Columns<br />

Comprehensive High Purity 1.5µm Selectivity Options<br />

Sub 2µm particles deliver efficiency and speed, but critical to success is<br />

having the right stationary phase selectivity. Six VisionHT high purity phases<br />

are available, each with unique separation benefits. C18-HL, with maximum<br />

bonded phase coverage, is ideal for complex hydrophobic samples. Use C18-B<br />

for basic compounds at neutral pH, often a requirement for mass spec work in<br />

the pharmaceutical industry. Reserve the C18 and C18-P for fastest analysis<br />

times. Both offer increased polar interactions to make neutral, non-polar<br />

compounds elute faster and retain polar compounds longer. The HILIC and<br />

Silica packings are normal phases that typically use near exclusive organic<br />

mobile phases; an advantage when seeking highest mass spec sensitivity.<br />

VisionHT phases have exceptionally rigid silica structure that withstands<br />

routine use of 12,000psig pressure often required in this new technology.<br />

Reproducible silica synthesis, bonding and column packing guarantee<br />

low bleed and excellent column-to-column consistency.<br />

VisionHT Phase Specifications<br />

Base<br />

Material<br />

Spherical<br />

Particle Carbon Pore Surface<br />

Size Load Size Area Endcapped<br />

1.5µm 10% 120Å 220m 2 /g Yes 1–10 Fully bonded silica, ultra<br />

pH<br />

Range* Feature Benefits<br />

Packing<br />

C18-HL<br />

High capacity for hydrophobic compounds. Good<br />

Silica<br />

high purity silica peak symmetry.<br />

C18-B Spherical 1.5µm 5% 120Å 220m 2 /g Proprietary 1–10 High purity silica and Improved performance of basic compounds at<br />

Silica<br />

unique endcapping. neutral pH. Better sensitivity and peak shape by<br />

mass spec for basic compounds, without the need<br />

for acidified mobile phases.<br />

C18 Spherical 1.5µm 6% 100Å 200m 2 /g Yes 1–10 Moderate silica exposure Classic reversed-phase selectivity. Reduced<br />

Silica<br />

bonding is optimized for speed and sensitivity.<br />

C18-P Spherical 1.5µm 5% 100Å 200m 2 /g No 1–10 High silica exposure, low Unique polar selectivity. Low carbon load gives<br />

Silica<br />

carbon load<br />

fastest reversed-phase elution times while retaining<br />

HILIC<br />

Silica<br />

Spherical<br />

Silica<br />

Spherical<br />

Silica<br />

*Choice of buffer is critical at pH >8.<br />

1.5µm NA 120Å 220m 2 /g No 2–8 Polar phase with shorter<br />

equilibration times.<br />

Shipped in ACN/Water.<br />

1.5µm NA 120Å 220m 2 /g No 2–8 Traditional normal phase<br />

for use in 100% organic<br />

mobile phases<br />

polar compounds longer.<br />

Peak reversal compared to reversed-phase. Ideal<br />

for very polar compounds with high organic mobile<br />

phases for improved sensitivity by MS.<br />

For isomeric separation of non-aqueous compatible<br />

compounds by absorption chromatography.<br />

7443<br />

hplc columns | small molecule<br />

k'<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

VisionHT Reversed-Phase<br />

VisionHT Selectivity<br />

Selectivity<br />

k' Phenol<br />

k' Methyl Alanine<br />

k' Butyl Benzoic Acid<br />

k' Toluene<br />

C18-P<br />

C18<br />

C18-B<br />

VisionHT Phase<br />

C18-HL<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

Separate Highly Basic Components at<br />

Neutral pH with Vision HT C18-B<br />

1<br />

2<br />

3<br />

1. Phenylephrine<br />

2. Diphenhydramine<br />

3. Amitriptyline<br />

0 1 2 3 4 5 Min.<br />

Column: VisionHT C18-B, 1.5µm, 2.0 x 50mm<br />

Mobile Phase: 50mM Ammonium Formate pH 7:Methanol (20:80)<br />

Column Temp: 40°C<br />

Flow Rate: 0.2mL/min<br />

Detector: UV at 210nm<br />

www.discoverysciences.com 35


analytical hplc<br />

hplc columns | small molecule<br />

<strong>Grace</strong> ® VisionHT Ultra High-Pressure Columns<br />

Unique Column Hardware Advantages<br />

You can erode the benefits of sub 2µm media if packed in<br />

an inefficient column design. VisionHT hardware uses<br />

thin screens, instead of traditional frits, to retain media and<br />

minimize dead volume. A unique insert combination seals<br />

endfittings leak-free to 18,000psig. Various dimensions offer<br />

even more flexibility over analysis speed and resolution.<br />

VisionHT Hardware Specifications<br />

Dead volume:<br />


analytical hplc<br />

<strong>Grace</strong> ® VisionHT Ultra High-Pressure Columns<br />

Protect Your UHPLC Column Investment<br />

The smaller diameters and finer porosity frits required in<br />

UHPLC creates a higher likelihood of column and system<br />

blockage. Trace contaminates not normally problematic<br />

for traditional LC, may now pose backpressure issues.<br />

VisionHT guards protect your column to minimize down<br />

time and reduce cost.<br />

Two guard formats available: Integral and stand-alone.<br />

Couple the zero-dead volume integral guard directly to<br />

any VisionHT column, and realize absolutely no loss in<br />

efficiency. Use the stand-alone version to protect other<br />

manufacturers’ UHPLC columns, or as an on-line enrichment<br />

device.<br />

Prevent Column Blockage with Integral Guards<br />

0 0.5 1.0 1.5 2.0 Min.<br />

No loss in efficiency.<br />

VisionHT Integral Guard System<br />

N=174K/m<br />

with guard<br />

without guard<br />

Replace existing endfitting with the integral guard endfitting. Change<br />

guard cartridges as necessary.<br />

7456<br />

VisionHT Ultra High-Pressure Columns<br />

Packing Format i.d. x Length Part No.<br />

C18-HL, 1.5µm Ultra High-Pressure 1 x 20mm 5142540<br />

Ultra High-Pressure 1 x 30mm 5142541<br />

Ultra High-Pressure 1 x 50mm 5142542<br />

Ultra High-Pressure 1 x 100mm 5142543<br />

Ultra High-Pressure 2 x 20mm 5142544<br />

Ultra High-Pressure 2 x 30mm 5142545<br />

Ultra High-Pressure 2 x 50mm 5142546<br />

Ultra High-Pressure 2 x 100mm 5142547<br />

C18-B, 1.5µm Ultra High-Pressure 1 x 30mm 5141903<br />

Ultra High-Pressure 1 x 50mm 5141904<br />

Ultra High-Pressure 1 x 100mm 5141905<br />

Ultra High-Pressure 1 x 20mm 5141902<br />

Ultra High-Pressure 2 x 20mm 5141906<br />

Ultra High-Pressure 2 x 30mm 5141907<br />

Ultra High-Pressure 2 x 50mm 5141908<br />

Ultra High-Pressure 2 x 100mm 5141909<br />

C18, 1.5µm Ultra High-Pressure 1 x 20mm 5139555<br />

Ultra High-Pressure 1 x 30mm 5139559<br />

Ultra High-Pressure 1 x 50mm 5139603<br />

Ultra High-Pressure 1 x 100mm 5139607<br />

Ultra High-Pressure 2 x 20mm 5139557<br />

Ultra High-Pressure 2 x 30mm 5139600<br />

Ultra High-Pressure 2 x 50mm 5139605<br />

Ultra High-Pressure 2 x 100mm 5139609<br />

C18-P, 1.5µm Ultra High-Pressure 1 x 20mm 5139556<br />

Ultra High-Pressure 1 x 30mm 5139601<br />

Ultra High-Pressure 1 x 50mm 5139604<br />

Ultra High-Pressure 1 x 100mm 5139608<br />

Ultra High-Pressure 2 x 20mm 5139558<br />

Ultra High-Pressure 2 x 30mm 5139602<br />

Ultra High-Pressure 2 x 50mm 5139606<br />

Ultra High-Pressure 2 x 100mm 5139610<br />

HILIC, 1.5µm Ultra High-Pressure 1 x 20mm 5141910<br />

Ultra High-Pressure 1 x 30mm 5141912<br />

Ultra High-Pressure 1 x 50mm 5141913<br />

Ultra High-Pressure 1 x 100mm 5141914<br />

Ultra High-Pressure 2 x 20mm 5141916<br />

Ultra High-Pressure 2 x 30mm 5141917<br />

Ultra High-Pressure 2 x 50mm 5141919<br />

Ultra High-Pressure 2 x 100mm 5141920<br />

SI, 1.5µm Ultra High-Pressure 1 x 50mm 5141921<br />

Ultra High-Pressure 1 x 100mm 5141923<br />

Ultra High-Pressure 2 x 50mm 5141922<br />

Ultra High-Pressure 2 x 100mm 5141924<br />

hplc columns | small molecule<br />

Stand-Alone Guard System<br />

In-line guard system expands applications beyond column protection.<br />

Use as a sample enrichment device or to protect any uhplc<br />

commercially available column.<br />

7457<br />

VisionHT Guard Cartridges<br />

Packing Format i.d. x Length Qty. Part No.<br />

C18HL, 1.5µm Ultra High-Pressure 1 x 5mm 3/pk 5142549<br />

Ultra High-Pressure 2 x 5mm 3/pk 5142548<br />

C18 B, 1.5µm Ultra High-Pressure 1 x 5mm 3/pk 5141953<br />

Ultra High-Pressure 2 x 5mm 3/pk 5141952<br />

C18, 1.5µm Ultra High-Pressure 1 x 5mm 3/pk 5141950<br />

Ultra High-Pressure 2 x 5mm 3/pk 5141594<br />

C18-P, 1.5µm Ultra High-Pressure 1 x 5mm 3/pk 5141951<br />

Ultra High-Pressure 2 x 5mm 3/pk 5141595<br />

HILIC, 1.5µm Ultra High-Pressure 1 x 5mm 3/pk 5141955<br />

Ultra High-Pressure 2 x 5mm 3/pk 5141954<br />

SI, 1.5µm Ultra High-Pressure 1 x 5mm 3/pk 5141957<br />

Ultra High-Pressure 2 x 5mm 3/pk 5141956<br />

Integral Guard Column Holder For VisionHT 3118351<br />

Stand-Alone Guard Holder 3118350<br />

www.discoverysciences.com 37


analytical hplc<br />

hplc columns | small molecule<br />

Alltech ® Alltima HP Introduction<br />

High-Stability, High-Purity, High-Performance, Low-Bleed Columns for<br />

Demanding Applications<br />

• Better Peak Symmetry—high-purity silica eliminates peak tailing problems<br />

• Long Column Life—exceptional column stability minimizes downtime and reduces cost<br />

• Ideal for Microbore or Critical Analysis—low to no detectable column bleed<br />

• Variety of Phases and Formats—optimizes retention, resolution, and analysis time<br />

Alltima HP combines our best phase chemistries with high-purity silica. The result is<br />

one product family with selectivity and performance needed to overcome your most challenging<br />

separation needs.<br />

Alltech ® Alltima HP Phase Specifications<br />

Pore<br />

Size<br />

Surface<br />

Area<br />

Carbon<br />

Load<br />

Endcapped?<br />

Phase Description Base Particle Particle Size<br />

Phase<br />

USP<br />

C18 For classic reversed-phase applications Silica Spherical 3, 5µm 190Å 200 m 2 /g 12% Monomeric Yes L1<br />

C18 EPS Reversed-phase C18 with extended polar selectivity Silica Spherical 3, 5µm 190Å 200 m 2 /g 4% Monomeric Yes L1<br />

C18 HiLoad Higher carbon load for stronger retention Silica Spherical 3, 5µm 100Å 450 m 2 /g 24% Monomeric Yes L1<br />

C18 AQ 100% water wettable Silica Spherical 3, 5µm 100Å 450 m 2 /g 20% Monomeric Yes L1<br />

C18 Amide Low bleed polar-embedded phase compatible Silica Spherical 3, 5µm 190Å 200 m 2 /g 12% Monomeric Yes L1<br />

with microbore<br />

C8 For reversed-phase applications where C18 is Silica Spherical 3, 5µm 190Å 200 m 2 /g 8% Monomeric Yes L7<br />

too retentive<br />

Cyano Stable, long-life cyano phase Silica Spherical 3, 5µm 190Å 200 m 2 /g 4% Monomeric Yes L10<br />

Silica For general purpose normal-phase applications Silica Spherical 3, 5µm 100Å 450 m 2 /g — — No L3<br />

HILIC Hydrophillic Interaction Chromatography for highly<br />

polar analytes<br />

Silica Spherical 1.5, 3, 5µm 120Å 230 m 2 /g — — — L3<br />

Basic Compounds at Neutral pH<br />

1<br />

2<br />

0 1 2 3 4 5 6 7 Min.<br />

3<br />

The Alltima HP phases demonstrate excellent peak symmetry of highly basic analytes at pH 7.0.<br />

Peak<br />

USP Tailing*<br />

1. Diphenhydramine 1.29<br />

2. Nortriptyline 1.41<br />

3. Amitriptyline 1.27<br />

*Tailing Factor was determined in accordance with USP method.<br />

Column: Alltima HP C18, 5µm, 4.6 x 150mm<br />

Mobile Phase: 25mM Potassium Phosphate, pH 7.0:Methanol (15:85)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Basic Compound Stability at pH1 and pH10<br />

1<br />

1<br />

2<br />

2 3 4<br />

2 3 4<br />

4<br />

31<br />

Final Acid<br />

Final Base<br />

Retention Times<br />

1. Uracil<br />

10249<br />

0.56<br />

10250<br />

0.55<br />

10252<br />

0.55<br />

2. Phenol 0.82 0.81 0.81<br />

3. N,N-Diethyl-m-Toluamide 1.08 1.08 1.08<br />

4. Toluene 1.89 1.88 1.89<br />

Column: Alltima HP C18, 5µm, 4.6 x 50mm<br />

Mobile Phase: Acetonitrile:Water (58:42)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Final Acid: washed with 24,000 column volumes of Acetonitrile:Dilute Sulfuric Acid,<br />

pH 1.0 (50:50) at 60°C.<br />

Final Base: washed with 24,000 column volumes of Acetonitrile:Ammonium<br />

Hydroxide, pH 10 (50:50) at 20°C.<br />

Initial<br />

0 1<br />

2 3 Min.<br />

The Alltima HP phases demonstrate exceptional stability from pH 1.0 to 10.<br />

38<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Alltima HP Introduction<br />

The Alltima HP Family Demonstrates Low Bleed<br />

Alltima HP columns are among the lowest-bleed columns available, making them ideal for microbore applications. Our C18<br />

Amide polar-embedded phase has significantly lower column bleed than competitive amide columns.<br />

Relative Abundance Level (X10 5 )<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

Column Bleed by ESI-MS — Alltima HP vs. Competitive Columns<br />

Alltech ® Alltima HP<br />

Competitors<br />

0.82 0.82 0.82 0.82<br />

1.2<br />

2.91<br />

2.52<br />

11.8<br />

13.2<br />

hplc columns | small molecule<br />

0<br />

No<br />

Column<br />

Alltima HP<br />

Silica<br />

C18<br />

Alltima HP<br />

Alltima HP<br />

C18 HiLoad<br />

C18 MS 1<br />

C18 MS 2<br />

Alltima HP<br />

C18 Amide<br />

C18 Amide 1<br />

C18 Amide 2<br />

Alltima HP Method Development Kits<br />

best<br />

value<br />

Three Different Kits with Different Selectivities<br />

Whether you are developing a new method, or just not<br />

satisfied with an existing separation, the Alltima HP family<br />

can help optimize your separation. Your best value for method<br />

development—purchase a kit and receive three columns for<br />

the price of two.<br />

6113<br />

6904<br />

7345<br />

Alltima HP Method Development Kits<br />

Description Includes: i.d. x Length Part No.<br />

Kit 1— C18 Mix, 3µm<br />

Expedite MS Kit 1 C18, C18 HiLoad, C18 Amide (87674, 87692, 87728) 2.1 x 20mm 87854<br />

Analytical Kit 1 C18, C18 HiLoad, C18 Amide (87668, 87686, 87722) 4.6 x 150mm 87850<br />

Rocket Kit 1 C18, C18 HiLoad, C18 Amide (87672, 87690, 87726) 7 x 53mm 87852<br />

Kit 2— Alternate Mix, 3µm<br />

Expedite MS Kit 2 C18 HiLoad, C8, CN (87692, 87746, 87764) 2.1 x 20mm 87864<br />

Analytical Kit 2 C18 HiLoad, C8, CN (87686, 87740, 87760) 4.6 x 150mm 87860<br />

Rocket Kit 2 C18 HiLoad, C8, CN (87690, 87744, 87762) 7 x 53mm 87862<br />

Kit 3 — Polar Mix, 3µm<br />

Expedite MS Kit 3 C18 EPS, C18 Amide, CN (87710, 87728, 87764) 2.1 x 20mm 87874<br />

Analytical Kit 3 C18 EPS, C18 Amide, CN (87704, 87722, 87758) 4.6 x 150mm 87870<br />

Rocket Kit 3 C18 EPS, C18 Amide, CN (87708, 87726, 87762) 7 x 53mm 87872<br />

tech tip<br />

Want high throughput on a conventional (non-ultra<br />

high-pressure) system?<br />

Choose the Rocket column format—no modifications<br />

necessary to your existing HPLC system. Choose Expedite<br />

columns for low volume and microbore systems. See page 31<br />

for more explanation of the Rocket and Expedite formats.<br />

www.discoverysciences.com 39


analytical hplc<br />

hplc columns | small molecule<br />

40<br />

Alltech ® Alltima HP<br />

Reversed-Phase Columns<br />

Selectivity Options in One Product Family<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

C18:<br />

• Classic reversed-phase retention and selectivity<br />

C18 AQ:<br />

• 100% water wettable and high carbon loading for greater<br />

mobile phase range<br />

EPS C18:<br />

• Unique selectivity that succeeds when traditional<br />

reversed-phase columns fail<br />

• Greater retention and enhanced peak symmetry for polar<br />

compounds<br />

C18 HiLoad:<br />

• Superior retention and loadability for resolution of<br />

complex samples<br />

C18 Amide:<br />

• The first polar-embedded packing ideal for microbore<br />

• Excellent peak shape without phase bleed<br />

• Ideal for basic compounds in neutral to alkaline pH<br />

C8:<br />

• Less hydrophobic retention than C18<br />

<br />

<br />

<br />

<br />

Alltima HP Selectivity<br />

<br />

<br />

<br />

<br />

Alltima HP Packing<br />

<br />

12<br />

1 2 3<br />

Acid, Base, and Neutral Test Mix<br />

5<br />

3<br />

4<br />

5<br />

4<br />

1 2<br />

3<br />

6<br />

0 2 4 6 8 Min.<br />

Column: 4.6 x 150mm<br />

Mobile Phase: 50mM KH2PO4, pH 3.0:CH3CN (40:60)<br />

Column Temp: Ambient (22°C)<br />

Flow Rate: 1.0mL/min<br />

Injection Vol.: 5µL<br />

Detector: UV at 254nm<br />

www.discoverysciences.com<br />

4<br />

6<br />

5<br />

6<br />

1. Uracil<br />

2. Pyridine<br />

3. Phenol<br />

4. N,N-diethyl-m-toluamide<br />

5. 4-Butyl Benzoic Acid<br />

6. Toluene<br />

C18<br />

EPS C18<br />

C18 HiLoad<br />

Alltima HP HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 3µm* Capillary 0.150 X 50mm 22153<br />

Capillary 0.150 X100mm 22154<br />

Capillary 0.150 X150mm 22155<br />

Capillary 0.300 X 50mm 22156<br />

Capillary 0.300 X100mm 22157<br />

Capillary 0.300 X150mm 22158<br />

Expedite MS 2.1 x 10mm 87673<br />

Expedite MS 2.1 x 20mm 87674<br />

Microbore 2.1 x 50mm 87504<br />

Microbore 2.1 x 100mm 87669<br />

Microbore 2.1 x 150mm 87670<br />

Solvent-Reducer 3.0 x 150mm 87601<br />

Expedite MS 4.6 x 10mm 87675<br />

Expedite MS 4.6 x 20mm 87676<br />

Analytical 4.6 x 50mm 87826<br />

Analytical 4.6 x 100mm 87667<br />

Analytical 4.6 x 150mm 87668<br />

Rocket 7 x 33mm 87671<br />

Rocket 7 x 53mm 87672<br />

C18, 5µm Microbore 2.1 x 150mm 87681<br />

Microbore 2.1 x 250mm 87682<br />

Solvent-Reducer 3.0 x 150mm 87602<br />

Solvent-Reducer 3.0 x 250mm 87603<br />

Analytical 4.6 x 150mm 87679<br />

Analytical 4.6 x 250mm 87680<br />

C18 AQ, 3µm* Capillary 0.150 x 50mm 22560<br />

Capillary 0.150 x 100mm 22561<br />

Capillary 0.150 x 150mm 22562<br />

Capillary 0.300 x 50mm 22563<br />

Capillary 0.300 x 100mm 22564<br />

Capillary 0.300 x 150mm 22565<br />

Expedite MS 2.1 x 10mm 87813<br />

Expedite MS 2.1 x 20mm 87814<br />

Microbore 2.1 x 100mm 87809<br />

Microbore 2.1 x 150mm 87810<br />

Expedite MS 4.6 x 10mm 87815<br />

Expedite MS 4.6 x 20mm 87816<br />

Analytical 4.6 x 50mm 87832<br />

Analytical 4.6 x 100mm 87807<br />

Analytical 4.6 x 150mm 87808<br />

Rocket 7 x 33mm 87811<br />

Rocket 7 x 53mm 87812<br />

C18 AQ, 5µm Microbore 2.1 x 150mm 87821<br />

Microbore 2.1 x 250mm 87822<br />

Analytical 4.6 x 150mm 87819<br />

Analytical 4.6 x 250mm 87820<br />

C18 EPS, 3µm Expedite MS 2.1 x 10mm 87709<br />

Expedite MS 2.1 x 20mm 87710<br />

Microbore 2.1 x 50mm 87508<br />

Microbore 2.1 x 100mm 87705<br />

Microbore 2.1 x 150mm 87706<br />

Solvent-Reducer 3.0 x 150mm 87604<br />

Expedite MS 4.6 x 10mm 87711<br />

Expedite MS 4.6 x 20mm 87712<br />

Analytical 4.6 x 50mm 87833<br />

Analytical 4.6 x 100mm 87703<br />

Analytical 4.6 x 150mm 87704<br />

Rocket 7 x 33mm 87707<br />

Rocket 7 x 53mm 87708<br />

C18 EPS, 5µm Microbore 2.1 x 150mm 87717<br />

Microbore 2.1 x 250mm 87718<br />

Solvent-Reducer 3.0 x 150mm 87605<br />

Solvent-Reducer 3.0 x 250mm 87606<br />

Analytical 4.6 x 150mm 87715<br />

Analytical 4.6 x 250mm 87716<br />

*Other particle sizes and dimensions are available.


analytical hplc<br />

Alltech ® Alltima HP Reversed-Phase Columns<br />

Alltima HP HPLC Columns (continued)<br />

Packing Format i.d. x Length Part No.<br />

C18 Hi-Load, Capillary 0.150 x 50mm 22190<br />

3µm* Capillary 0.300 x 50mm 22193<br />

Expedite MS 2.1 x 10mm 87691<br />

Expedite MS 2.1 x 20mm 87692<br />

Microbore 2.1 x 50mm 87506<br />

Microbore 2.1 x 100mm 87687<br />

Microbore 2.1 x 150mm 87688<br />

Solvent-Reducer 3.0 x 150mm 87610<br />

Expedite MS 4.6 x 10mm 87693<br />

Expedite MS 4.6 x 20mm 87694<br />

Analytical 4.6 x 50mm 87827<br />

Analytical 4.6 x 100mm 87685<br />

Analytical 4.6 x 150mm 87686<br />

Rocket 7 x 33mm 87689<br />

Rocket 7 x 53mm 87690<br />

C18 Hi-Load, Microbore 2.1 x 150mm 87699<br />

5µm Microbore 2.1 x 250mm 87700<br />

Solvent-Reducer 3.0 x 150mm 87611<br />

Solvent-Reducer 3.0 x 250mm 87612<br />

Analytical 4.6 x 150mm 87697<br />

Analytical 4.6 x 250mm 87698<br />

C18 Amide, Capillary 0.150 x 50mm 22255<br />

3µm* Capillary 0.300 x 50mm 22258<br />

Expedite MS 2.1 x 10mm 87727<br />

Expedite MS 2.1 x 20mm 87728<br />

Microbore 2.1 x 50mm 87510<br />

Microbore 2.1 x 100mm 87723<br />

Microbore 2.1 x 150mm 87724<br />

Solvent-Reducer 3.0 x 150mm 87607<br />

Expedite MS 4.6 x 10mm 87729<br />

Expedite MS 4.6 x 20mm 87730<br />

Analytical 4.6 x 50mm 87829<br />

Analytical 4.6 x 100mm 87721<br />

Analytical 4.6 x 150mm 87722<br />

Rocket 7 x 33mm 87725<br />

Rocket 7 x 53mm 87726<br />

C18 Amide, Microbore 2.1 x 150mm 87735<br />

5µm Microbore 2.1 x 250mm 87736<br />

Solvent-Reducer 3.0 x 150mm 87608<br />

Solvent-Reducer 3.0 x 250mm 87609<br />

Analytical 4.6 x 150mm 87733<br />

Analytical 4.6 x 250mm 87734<br />

C8, 3µm* Capillary 0.150 x 50mm 22479<br />

Capillary 0.150 x 100mm 22480<br />

Capillary 0.150 x 150mm 22481<br />

Capillary 0.300 x 50mm 22482<br />

Capillary 0.300 x 100mm 22483<br />

Capillary 0.300 x 150mm 22484<br />

Expedite MS 2.1 x 10mm 87745<br />

Expedite MS 2.1 x 20mm 87746<br />

Microbore 2.1 x 50mm 87512<br />

Microbore 2.1 x 100mm 87741<br />

Microbore 2.1 x 150mm 87742<br />

Solvent-Reducer 3.0 x 150mm 87613<br />

Expedite MS 4.6 x 10mm 87747<br />

Expedite MS 4.6 x 20mm 87748<br />

Analytical 4.6 x 50mm 87830<br />

Analytical 4.6 x 100mm 87739<br />

Analytical 4.6 x 150mm 87740<br />

Rocket 7 x 33mm 87743<br />

Rocket 7 x 53mm 87744<br />

C8, 5µm Microbore 2.1 x 150mm 87753<br />

Microbore 2.1 x 250mm 87754<br />

Solvent-Reducer 3.0 x 150mm 87614<br />

Solvent-Reducer 3.0 x 250mm 87615<br />

Analytical 4.6 x 150mm 87751<br />

Analytical 4.6 x 250mm 87752<br />

*Other particle sizes and dimensions are also available.<br />

Alltima HP-Guard Cartridges<br />

Packing i.d. x Length Qty. Part No.<br />

C18 Capillary Guard, 3µm** 0.150 x 10mm ea 22578<br />

0.300 x 10mm ea 22579<br />

C18 All-Guard, 5µm* 2.1 x 7.5mm 3 87683<br />

3.0 x 7.5mm 3 87622<br />

4.6 x 7.5mm 3 87684<br />

C18 AQ Capillary Guard, 3µm** 0.150 x 10mm ea 22638<br />

0.300 x 10mm ea 22639<br />

C18 AQ All-Guard, 5µm* 2.1 x 7.5mm 3 87823<br />

4.6 x 7.5mm 3 87824<br />

C18 EPS All-Guard, 5µm* 2.1 x 7.5mm 3 87719<br />

3.0 x 7.5mm 3 87623<br />

4.6 x 7.5mm 3 87720<br />

C18 Hi-Load Capillary 0.150 x 10mm ea 22588<br />

Guard, 3µm** 0.300 x 10mm ea 22589<br />

C18 Hi-Load All-Guard, 5µm* 2.1 x 7.5mm 3 87701<br />

3.0 x 7.5mm 3 87624<br />

4.6 x 7.5mm 3 87702<br />

C18 Amide Capillary 0.150 x 10mm ea 22598<br />

Guard, 3µm** 0.300 x 10mm ea 22599<br />

C18 Amide All-Guard, 5µm* 2.1 x 7.5mm 3 87737<br />

3.0 x 7.5mm 3 87625<br />

4.6 x 7.5mm 3 87738<br />

C8 Capillary Guard, 3µm** 0.150 x 10mm ea 22648<br />

0.300 x 10mm ea 22648<br />

C8 All-Guard, 5µm* 2.1 x 7.5mm 3 87755<br />

3.0 x 7.5mm 3 87627<br />

4.6 x 7.5mm 3 87756<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

Capillary Guard Cartridge Holder<br />

Guard Holder for 0.100mm and 0.150mm Guards ea GR-3710E<br />

Guard Holder for 0.300mm and 0.500mm Guards ea GR-3710A<br />

*All-Guard holder required.<br />

**Other particle sizes and dimensions are available.<br />

tech tip<br />

Which guard format should I choose?<br />

Ideally, the guard should have the same or slightly smaller i.d. as<br />

the HPLC column. Efficiency will suffer, if the guard i.d. is larger<br />

than that of the column.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

hplc columns | small molecule<br />

www.discoverysciences.com 41


analytical hplc<br />

hplc columns | small molecule<br />

Alltech ® Alltima HP HILIC Columns<br />

Hydrophilic Interaction (HILIC) Columns for<br />

Highly Polar Basic Analytes<br />

• Superior retention of highly polar compounds<br />

• Increased sensitivity and lower detection limits<br />

with microbore<br />

• Available in 1.5µm particle size<br />

Hydrophilic Interaction Chromatography is ideal for<br />

separating and retaining very polar compounds that may<br />

not retain on traditional reversed-phase packings. Unlike<br />

reversed-phase columns, HILIC columns retain highly polar<br />

compounds with only small amounts of water in the mobile<br />

phase. These more volatile mobile phases increase sensitivity<br />

with microbore applications.<br />

1<br />

2<br />

Basic Drugs<br />

Reverse-Phase<br />

C18 Columns<br />

10949<br />

1<br />

2<br />

3<br />

4<br />

0 1 2 3 4 5 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

5<br />

Mixed Analyte HILIC<br />

1. Toluene<br />

2. Hydantoin<br />

3. Uracil<br />

4. Caffeine<br />

5. Allantoin<br />

Alltima HP HILIC, 5μm, 4.6 x 150mm<br />

(Part No. 86464)<br />

Acetonitrile:0.10M Ammonium Formate,<br />

pH 3.0 (95:5)<br />

1.0mL/min<br />

UV at 205nm<br />

10461<br />

Alternate selectivity compared to reversed-phase columns allows<br />

more separation possibilities.<br />

2<br />

1<br />

Alltima HP<br />

HILIC Columns<br />

0 1 2 3 4 5 6 7 8 9 10 Min.<br />

1. Albuterol<br />

2. Bamethan<br />

Column: Prevail C18 Column, 5μm, 4.6 x 150mm<br />

(Part No. 99208)<br />

Alltima HP HILIC Column, 5μm, 4.6 x 150mm,<br />

(Part No. 86464)<br />

Mobile Phase: 0.5M Ammonium Formate, pH 3.0:CH3CN (88:12)<br />

Acetonitrile:0.5M Ammonium Formate, pH 3.0 (85:15)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

Use Alltima HP HILIC's alternate selectivity for greater separation<br />

possibilities.<br />

tech tip<br />

Want high throughput on a conventional (non-ultra<br />

high-pressure) system?<br />

Choose the Rocket column format—no modifications<br />

necessary to your existing HPLC system. Choose Expedite<br />

columns for low volume and microbore systems. See page 31<br />

for more explanation of the Rocket and Expedite formats.<br />

Rocket<br />

Columns<br />

6904<br />

Expedite<br />

Columns<br />

6113<br />

Alltima HP Hilic HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

HILIC, 1.5µm Expedite MS 2.1 x 20mm 86471<br />

Expedite MS 4.6 x 20mm 86472<br />

Rocket 7 x 33mm 86467<br />

Rocket 7 x 53mm 86468<br />

HILIC, 3µm* Capillary 0.150 x 50mm 22515<br />

Capillary 0.150 x 100mm 22516<br />

Capillary 0.150 x 150mm 22517<br />

Capillary 0.300 x 50mm 22518<br />

Capillary 0.300 x 100mm 22519<br />

Capillary 0.300 x 150mm 22520<br />

Expedite MS 2.1 x 10mm 86473<br />

Expedite MS 2.1 x 20mm 86475<br />

Microbore 2.1 x 50mm 86461<br />

Microbore 2.1 x 150mm 86463<br />

Expedite MS 4.6 x 10mm 86474<br />

Expedite MS 4.6 x 20mm 86476<br />

Analytical 4.6 x 50mm 86460<br />

Analytical 4.6 x 150mm 86462<br />

Rocket 7 x 33mm 86469<br />

Rocket 7 x 53mm 86470<br />

HILIC, 5µm Microbore 2.1 x 150mm 86465<br />

Analytical 4.6 x 150mm 86464<br />

Analytical 4.6 x 250mm 86466<br />

*Other particle sizes and dimensions are available.<br />

Alltima HP HILIC Guard Cartridges<br />

Packing i.d. x Length Qty. Part No.<br />

HILIC Capillary Guard, 0.150 x 10mm ea 22658<br />

3µm** 0.300 x 10mm ea 22659<br />

HILIC All-Guard, 5µm* 2.1 x 7.5mm 3 86479<br />

4.6 x 7.5mm 3 86480<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

Capillary Guard Cartridge Holder<br />

Guard Holder for 0.100mm and 0.150mm Guards ea GR-3710E<br />

Guard Holder for 0.300mm and 0.500mm Guards ea GR-3710A<br />

*All-Guard holder required.<br />

**Other particle sizes and dimensions are available.<br />

42<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Alltima HP Normal-Phase Columns<br />

Cyano: • Superior stability<br />

• More reproducible separations than silica for<br />

normal-phase applications<br />

• Ideal for basic drug analysis<br />

Silica: • Normal phase<br />

% Changes in Retention<br />

-35<br />

-30<br />

-25<br />

-20<br />

-15<br />

-10<br />

-5<br />

-0<br />

Alltima HP Cyano —<br />

Much More Stable than Other Cyanos<br />

Alltima HP CN<br />

pH 1.0<br />

pH 7.5<br />

Brand A CN<br />

Brand B CN<br />

Brand C CN<br />

Brand D CN<br />

Brand E CN<br />

Brand F CN<br />

QC D4 Test: 70:30 H2O/CH3CN,1.0mL/min, UV at 254nm, 5µL<br />

D4Mix, Column 4.6 x 150mm, 22°C<br />

pH 1.0 Stability: Flushed with H2SO4 pH 1.0:Acetonitrile 50:50 at<br />

1.0mL/min for 3 days<br />

pH 7.5 Stability: Flushed with 20mM K2HPO4 pH 7.5:Acetonitrile<br />

50:50 at 1.0mL/min for 3 days<br />

Alltima HP HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Cyano, 3µm Expedite MS 2.1 x 10mm 87763<br />

Expedite MS 2.1 x 20mm 87764<br />

Microbore 2.1 x 50mm 87514<br />

Microbore 2.1 x 100mm 87759<br />

Microbore 2.1 x 150mm 87760<br />

Solvent-Reducer 3.0 x 150mm 87616<br />

Expedite MS 4.6 x 10mm 87765<br />

Expedite MS 4.6 x 20mm 87766<br />

Analytical 4.6 x 50mm 87825<br />

Analytical 4.6 x 100mm 87757<br />

Analytical 4.6 x 150mm 87758<br />

Rocket 7 x 33mm 87761<br />

Rocket 7 x 53mm 87762<br />

Cyano, 5µm Microbore 2.1 x 150mm 87781<br />

Microbore 2.1 x 250mm 87782<br />

Solvent-Reducer 3.0 x 150mm 87617<br />

Solvent-Reducer 3.0 x 250mm 87618<br />

Analytical 4.6 x 150mm 87769<br />

Analytical 4.6 x 250mm 87780<br />

Silica, 3µm Expedite MS 2.1 x 10mm 87791<br />

Expedite MS 2.1 x 20mm 87792<br />

Microbore 2.1 x 50mm 87516<br />

Microbore 2.1 x 100mm 87787<br />

Microbore 2.1 x 150mm 87788<br />

Solvent-Reducer 3.0 x 150mm 87619<br />

Expedite MS 4.6 x 10mm 87793<br />

Expedite MS 4.6 x 20mm 87794<br />

Analytical 4.6 x 50mm 87831<br />

Analytical 4.6 x 100mm 87785<br />

Analytical 4.6 x 150mm 87786<br />

Rocket 7 x 33mm 87789<br />

Rocket 7 x 53mm 87790<br />

0<br />

1. Deoxycorticosterone Acetate<br />

2. Hydrocortisone Acetate<br />

3. Cortisone Acetate<br />

4. Cortisone<br />

1<br />

2<br />

Corticosteroids<br />

3 4<br />

5<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 Min.<br />

Column: Alltima HP CN, 5μm, 4.6 x 150mm<br />

(Part No. 87769)<br />

Mobile Phase: Hexane:Isopropanol (93.7:6.3)<br />

Flow Rate: 2.0mL/min<br />

Column Temp: 35°C<br />

Detector: UV at 254nm<br />

6<br />

5. Prednisone<br />

6. Hydrocortisone<br />

7. Prednisolone<br />

7<br />

10391<br />

Alltima HP HPLC Columns (continued)<br />

Packing Format i.d. x Length Part No.<br />

Silica, 5µm Microbore 2.1 x 150mm 87799<br />

Microbore 2.1 x 250mm 87802<br />

Solvent-Reducer 3.0 x 150mm 87620<br />

Solvent-Reducer 3.0 x 250mm 87621<br />

Analytical 4.6 x 150mm 87797<br />

Analytical 4.6 x 250mm 87798<br />

Alltima HP All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

Cyano, 5µm 2.1 x 7.5mm 3 87783<br />

3.0 x 7.5mm 3 87626<br />

4.6 x 7.5mm 3 87784<br />

Silica, 5µm 2.1 x 7.5mm 3 87803<br />

3.0 x 7.5mm 3 87628<br />

4.6 x 7.5mm 3 87804<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

hplc columns | small molecule<br />

www.discoverysciences.com 43


analytical hplc<br />

hplc columns | small molecule<br />

Alltech ® Prevail Introduction<br />

Stable from 100% Organic to 100% Aqueous<br />

• Long column life in both highly aqueous and highly organic mobile phases<br />

• Excellent retention and reproducibility of highly polar analytes in 100% aqueous<br />

mobile phases<br />

• Strong retention of hydrophobic analytes in 100% organic mobile phases, no concerns<br />

of solubility, better sensitivity in microbore and ELSD applications<br />

• No phase collapse<br />

• Specialty phases for specific applications<br />

With one Prevail C18 column, retain polar compounds in aqueous mobile phases and hydrophobic compounds in organic<br />

mobile phases.<br />

Alltech ® Prevail Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 Select Silica Spherical 3, 5µm 110Å 350m 2 /g 17% Monomeric Yes L1<br />

C18 Silica Spherical 3, 5µm 110Å 350m 2 /g 15% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5µm 110Å 350m 2 /g 8% Monomeric Yes L7<br />

Phenyl Silica Spherical 3, 5µm 110Å 350m 2 /g 7% Monomeric Yes L11<br />

Cyano Silica Spherical 3, 5µm 110Å 350m 2 /g — Monomeric Yes L10<br />

Amino (NH2) Silica Spherical 3, 5µm 110Å 350m 2 /g — Monomeric No L8<br />

Silica Silica Spherical 3, 5µm 110Å 350m 2 /g — — — L3<br />

Organic Acid Silica Spherical 3, 5µm 110Å 350m 2 /g — Monomeric Yes —<br />

Carbohydrate ES Polymer Spherical 5µm — — — — — —<br />

Switch Between 100% Aqueous and 100% Organic Mobile Phases on the Same Column<br />

Water-Soluble Vitamins<br />

(100% Aqueous)<br />

9465<br />

Fat-Soluble Vitamins and Tocopherols<br />

(100% Organic)<br />

9405<br />

Water-Soluble Vitamins<br />

(100% Aqueous)<br />

9465<br />

3<br />

1. Thiamine<br />

2. Ascorbic Acid<br />

3. Nicotinic Acid<br />

4. Pyridoxine<br />

5. Niacinamide<br />

6. Pantothenic Acid<br />

1. Vitamin A<br />

2. δ-Tocopherol<br />

3. γ-Tocopherol<br />

4. α-Tocopherol<br />

(Vitamin E)<br />

5. Vitamin D2<br />

6. Vitamin D3<br />

7. Vitamin K<br />

4<br />

6<br />

3<br />

1. Thiamine<br />

2. Ascorbic Acid<br />

3. Nicotinic Acid<br />

4. Pyridoxine<br />

5. Niacinamide<br />

6. Pantothenic Acid<br />

1<br />

2<br />

4 5<br />

6<br />

wash with<br />

intermediate<br />

1<br />

2<br />

3<br />

5<br />

7<br />

wash with<br />

intermediate<br />

1<br />

2<br />

4 5<br />

6<br />

0 2 4 6 8 10 12 14 Min.<br />

0 2 4<br />

6<br />

8 10 12 14 Min.<br />

0 2 4 6 8 10 12 14 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Prevail C18, 5µm,<br />

4.6 x 150mm<br />

25mM KH2PO4<br />

pH 3.0:CH3CN (97:3)<br />

1.0mL/min<br />

UV at 212nm<br />

Column: Prevail C18, 5µm,<br />

4.6 x 150mm<br />

Mobile Phase: CH3CN:CH3OH (75:25)<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 220nm<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Prevail C18, 5µm,<br />

4.6 x 150mm<br />

25mM KH2PO4<br />

pH 3.0: CH3CN (97:3)<br />

1.0mL/min<br />

UV at 212nm<br />

Figure 1<br />

Figure 2<br />

Figure 3<br />

Prevail Columns have highly stable bonded phases that let you use one column for multiple mobile phase conditions. Even switching between<br />

extremes such as near 100% aqueous (Figure 1) to 100% organic conditions (Figure 2), and back to near 100% aqueous (Figure 3) on a routine<br />

basis is possible, provided that mobile phases are miscible.<br />

44<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Prevail Reversed-Phase Columns<br />

Prevail HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Select C18, Microbore 2.1 x 50mm 99309<br />

3µm Microbore 2.1 x 100mm 99312<br />

Microbore 2.1 x 150mm 99313<br />

Solvent-Reducer 3.0 x 150mm 99315<br />

Analytical 4.6 x 100mm 99302<br />

Analytical 4.6 x 150mm 99303<br />

Rocket 7 x 33mm 99304<br />

Rocket 7 x 53mm 99305<br />

Select C18, Microbore 2.1 x 150mm 99310<br />

5µm Microbore 2.1 x 250mm 99311<br />

Solvent-Reducer 3.0 x 150mm 99316<br />

Solvent-Reducer 3.0 x 250mm 99317<br />

Analytical 4.6 x 150mm 99300<br />

Analytical 4.6 x 250mm 99301<br />

C18, 3µm Microbore 150µm x 50mm 35762<br />

Microbore 150µm x 150mm 35764<br />

Microbore 300µm x 50mm 32831<br />

Microbore 300µm x 150mm 32832<br />

Microbore 1.0 x 100mm 43831<br />

Microbore 1.0 x 150mm 43843<br />

Expedite MS 2.1 x 10mm 43861<br />

Expedite MS 2.1 x 20mm 43827<br />

Microbore 2.1 x 50mm 43818<br />

Microbore 2.1 x 100mm 43871<br />

Microbore 2.1 x 150mm 99200<br />

Solvent-Reducer 3.0 x 150mm 99322<br />

Expedite MS 4.6 x 10mm 43878<br />

Expedite MS 4.6 x 20mm 43804<br />

Analytical 4.6 x 50mm 43829<br />

Analytical 4.6 x 100mm 99202<br />

Analytical 4.6 x 150mm 99204<br />

Rocket 7 x 33mm 99280<br />

Rocket 7 x 53mm 99279<br />

tech tip<br />

Want high throughput on a conventional (non-ultra<br />

high-pressure) system?<br />

Choose the Rocket column format—no modifications<br />

necessary to your existing HPLC system. Choose Expedite<br />

columns for low volume and microbore systems. See page 31 for<br />

more explanation of the Rocket and Expedite formats.<br />

Prevail HPLC Columns (continued)<br />

Packing Format i.d. x Length Part No.<br />

C18, 5µm Microbore 150µm x 50mm 35792<br />

Microbore 150µm x 150mm 35794<br />

Microbore 300µm x 50mm 32815<br />

Microbore 300µm x 150mm 32816<br />

Microbore 2.1 x 150mm 99206<br />

Solvent-Reducer 3.0 x 150mm 99320<br />

Solvent-Reducer 3.0 x 250mm 99321<br />

Analytical 4.6 x 50mm 43903<br />

Analytical 4.6 x 150mm 99208<br />

Analytical 4.6 x 250mm 99210<br />

C8, 3µm Microbore 2.1 x 150mm 99212<br />

Solvent-Reducer 3.0 x 150mm 99325<br />

Analytical 4.6 x 50mm 43922<br />

Analytical 4.6 x 100mm 99214<br />

Analytical 4.6 x 150mm 99216<br />

C8, 5µm Microbore 2.1 x 150mm 99218<br />

Solvent-Reducer 3.0 x 150mm 99323<br />

Solvent-Reducer 3.0 x 250mm 99324<br />

Analytical 4.6 x 150mm 99224<br />

Analytical 4.6 x 250mm 99229<br />

Phenyl, 3µm Microbore 1.0 x 100mm 43893<br />

Microbore 1.0 x 150mm 43859<br />

Expedite MS 2.1 x 10mm 43873<br />

Expedite MS 2.1 x 20mm 43885<br />

Microbore 2.1 x 50mm 43819<br />

Microbore 2.1 x 100mm 43872<br />

Microbore 2.1 x 150mm 99231<br />

Solvent-Reducer 3.0 x 150mm 99328<br />

Expedite MS 4.6 x 10mm 43887<br />

Expedite MS 4.6 x 20mm 43815<br />

Analytical 4.6 x 50mm 43869<br />

Analytical 4.6 x 100mm 99233<br />

Analytical 4.6 x 150mm 99235<br />

Rocket 7 x 33mm 99282<br />

Rocket 7 x 53mm 99281<br />

Phenyl, 5µm Microbore 2.1 x 150mm 99237<br />

Solvent-Reducer 3.0 x 150mm 99326<br />

Solvent-Reducer 3.0 x 250mm 99327<br />

Analytical 4.6 x 150mm 99239<br />

Analytical 4.6 x 250mm 99241<br />

hplc columns | small molecule<br />

9450<br />

9451<br />

9452<br />

Prevail Bonded Phases are Stable in 100% Aqueous Conditions<br />

Prevail C18, 5µm, 4.6 x 150mm<br />

Competitor A C18, 5µm, 4.6 x 150mm<br />

1<br />

Catecholamines<br />

1 2<br />

1. Norepinephrine<br />

1<br />

2<br />

2. Epinephrine<br />

3. 5-Hydroxydopamine<br />

1<br />

2<br />

3<br />

Mobile Phase: 25mM KH2PO4, pH 2.7<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 270nm<br />

After 24 hrs.<br />

After 8 hrs.<br />

After 20 min.<br />

3<br />

3<br />

2<br />

3<br />

9453<br />

9454<br />

9455<br />

0 1 2 3 4 5 6 Min.<br />

0 1 2 3 4 5 6 Min.<br />

www.discoverysciences.com 45


analytical hplc<br />

hplc columns | small molecule<br />

Alltech ® Prevail Normal-Phase Columns<br />

Prevail HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Cyano, 3µm Microbore 2.1 x 150mm 99243<br />

Solvent-Reducer 3.0 x 150mm 99338<br />

Analytical 4.6 x 50mm 43924<br />

Analytical 4.6 x 100mm 99245<br />

Analytical 4.6 x 150mm 99247<br />

Cyano, 5µm Microbore 2.1 x 150mm 99249<br />

Solvent-Reducer 3.0 x 150mm 99329<br />

Solvent-Reducer 3.0 x 250mm 99330<br />

Analytical 4.6 x 150mm 99251<br />

Analytical 4.6 x 250mm 99253<br />

Amino, 3µm Analytical 4.6 x 50mm 43926<br />

Analytical 4.6 x 100mm 99257<br />

Analytical 4.6 x 150mm 99259<br />

Amino, 5µm Analytical 4.6 x 150mm 99263<br />

Analytical 4.6 x 250mm 99265<br />

Silica, 3µm Microbore 1.0 x 100mm 43832<br />

Microbore 1.0 x 150mm 43806<br />

Expedite MS 2.1 x 10mm 43841<br />

Expedite MS 2.1 x 20mm 43826<br />

Microbore 2.1 x 50mm 43868<br />

Microbore 2.1 x 100mm 43805<br />

Microbore 2.1 x 150mm 99267<br />

Solvent-Reducer 3.0 x 150mm 99341<br />

Expedite MS 4.6 x 10mm 43858<br />

Expedite MS 4.6 x 20mm 43816<br />

Analytical 4.6 x 50mm 43842<br />

Analytical 4.6 x 100mm 99269<br />

Analytical 4.6 x 150mm 99271<br />

Rocket 7 x 33mm 99284<br />

Rocket 7 x 53mm 99283<br />

Prevail HPLC Columns (continued)<br />

Packing Format i.d. x Length Part No.<br />

Silica, 5µm Analytical 2.1 x 150mm 99273<br />

Solvent-Reducer 3.0 x 150mm 99339<br />

Solvent-Reducer 3.0 x 250mm 99340<br />

Analytical 4.6 x 150mm 99275<br />

Analytical 4.6 x 250mm 99277<br />

Prevail All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

Select C18, 5µm 2.1 x 7.5mm 3 96690<br />

3.0 x 7.5mm 3 99119<br />

4.6 x 7.5mm 3 96455<br />

C18, 5µm 2.1 x 7.5mm 3 96682<br />

3.0 x 7.5mm 3 99350<br />

4.6 x 7.5mm 3 99286<br />

C8, 5µm 2.1 x 7.5mm 3 99128<br />

3.0 x 7.5mm 3 99351<br />

4.6 x 7.5mm 3 99287<br />

Phenyl, 5µm 2.1 x 7.5mm 3 99130<br />

3.0 x 7.5mm 3 99352<br />

4.6 x 7.5mm 3 99288<br />

Cyano, 5µm 2.1 x 7.5mm 3 99131<br />

3.0 x 7.5mm 3 99353<br />

4.6 x 7.5mm 3 99289<br />

Amino, 5µm 4.6 x 7.5mm 3 99290<br />

Silica, 5µm 2.1 x 7.5mm 3 99133<br />

3.0 x 7.5mm 3 99354<br />

4.6 x 7.5mm 3 99291<br />

All-Guard Cartridge Holder ea 80101<br />

*All-Guard holder required. Other particle sizes available.<br />

Alltech ® Prevail Organic Acid Columns<br />

Get Unsurpassed Resolution for Common<br />

Organic Acids<br />

• Acid stable for long column lifetimes<br />

• Silica-based for maximum efficiency and high-resolution<br />

• Short run times and high sample throughput at ambient<br />

temperature with Rocket format<br />

• Lower cost than polymeric organic acid columns<br />

Prevail Organic Acid (OA) columns separate common<br />

organic acids with an unsurpassed combination of resolution,<br />

speed, sensitivity, and simplicity. A simple acidic phosphate<br />

buffer and a Prevail OA column at ambient temperature will<br />

separate 11 short-chain organic acids in less than 6 minutes.<br />

Use pH to adjust column selectivity. Lowering the mobile<br />

phase pH progressively suppresses the ionization of the<br />

carboxylic acids, making them more hydrophobic. This gives<br />

you the ability to move these peaks relative to other peaks in<br />

the chromatogram, and it simplifies method development.<br />

1<br />

2<br />

3 4 5 67 8<br />

Figure 1 - Organic Acids<br />

9 10<br />

11<br />

0 1 2 3 4 5 6 7 8 Min.<br />

Column: Prevail Organic Acid, 5µm, 4.6 x 150mm<br />

(Part No. 88640)<br />

Mobile Phase: 25mM KH2PO4, pH 2.5<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 210nm<br />

1. Oxalic Acid<br />

2. Tartaric Acid<br />

3. Formic Acid<br />

4. Malic Acid<br />

5. Lactic Acid<br />

6. Acetic Acid<br />

7. Diglycollic Acid<br />

8. Maleic Acid<br />

9. Citric Acid<br />

10. Succinic Acid<br />

11. Fumaric Acid<br />

Separate 11 short-chain organic acids in less than six minutes.<br />

9384<br />

Prevail HPLC Columns<br />

Standard<br />

Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

OA, 3µm Microbore 2.1 x 100mm 88648 —<br />

Analytical 4.6 x 100mm 88650 88750<br />

Analytical 4.6 x 150mm 88655 88755<br />

Rocket 7 x 33mm 99292 —<br />

Rocket 7 x 53mm 50755 —<br />

OA, 5µm Analytical 4.6 x 150mm 88640 88740<br />

Analytical 4.6 x 250mm 88645 88745<br />

Prevail All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

Organic Acid, 5µm 4.6 x 7.5mm 3 96429<br />

All-Guard Cartridge Holder ea 80101<br />

*All-Guard holder required. Other particle sizes available.<br />

46<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Prevail Carbohydrate ES Columns<br />

Get Better Retention Times, Longer Column Life, and Improved Baselines Compared to<br />

Traditional Amino Carbohydrate Columns<br />

• Longer column life: Hybrid phase has the ruggedness of silica with the stability of a polymer<br />

• Quieter baselines compared to traditional amino carbohydrate columns, even with gradients<br />

• Reduce run times with more mobile phase choices<br />

• Compatible with gradient ELSD applications<br />

Quiet Gradient Baselines<br />

Prevail Carbohydrate ES Columns are excellent for<br />

isocratic separations with common detectors, but the<br />

column’s real power shows with the ELSD and a solvent<br />

gradient. Enjoy the powerful selectivity, reduced run times,<br />

and efficient peaks from gradients while seeing the quiet,<br />

stable baselines that maximize sensitivity.<br />

9354<br />

9379<br />

1<br />

2 3<br />

4 5 6<br />

7<br />

4 5 6<br />

10 11 13<br />

7<br />

8 9 12<br />

0 5 10 15 20 25 Min.<br />

1<br />

2<br />

3<br />

Enhanced Detector Sensitivity Through Flat Gradient Baselines<br />

12<br />

13<br />

14<br />

15<br />

18 19 20 21 22 23 24 Min.<br />

Silica Based<br />

Amino Column<br />

9486<br />

Prevail<br />

Carbohydrate ES Column<br />

(Part No. 35101)<br />

Better Resolution and Peak Shape<br />

Prevail Carbohydrate ES Columns are versatile<br />

enough for mono- and oligosaccharides and sugar alcohols.<br />

They produce single peaks for reducing sugars at ambient<br />

temperatures, eliminating the need for column heating.<br />

1. Dextrose<br />

2. Maltose<br />

3. Maltotriose<br />

4. Maltotetraose<br />

5. Maltopentaose<br />

6. Maltohexaose<br />

7. Maltoheptaose<br />

8. Maltooctaose<br />

9. Maltononaose<br />

10. Maltodecaose<br />

11. Maltoundecaose<br />

12. Maltododecaose<br />

13. Maltotridecaose<br />

14. Maltotetradecaose<br />

15. Maltopentadecaose<br />

Column: 4.6 x 250mm<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 15<br />

%B: 35 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

hplc columns | small molecule<br />

Use gradients with a Prevail Carbohydate ES column and the ELSD for shorter run times, better resolution, and greater sensitivity.<br />

By comparison, silica-based amino columns give noisy, shifting baselines.<br />

1<br />

2<br />

3<br />

4<br />

6<br />

5<br />

7<br />

Pepsi One ® Cola<br />

0 5 10 15 20 25 30 35 40 Min.<br />

8<br />

10530<br />

1. Sucralose<br />

2. Unknown 1<br />

3. Fructose<br />

4. Glucose<br />

5. Unknown 2<br />

6. Sucrose<br />

7. Maltose<br />

8. Maltodextrins<br />

Column: Prevail Carbohydrate ES, 5µm, 4.6 x 250mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 20 20 30 30 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column Temp: Ambient<br />

Prevail HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Carbohydrate ES, Analytical 4.6 x 150mm 35102<br />

5µm Analytical 4.6 x 250mm 35101<br />

Rocket 7 x 53mm 35104<br />

1<br />

2 4<br />

3<br />

Robitussin ® Flu Syrup<br />

1. Sucralose<br />

2. Fructose<br />

3. Sorbitol<br />

4. Glucose<br />

5. Sucrose<br />

6. Maltose<br />

5 6<br />

0 5 10 15 20 25 30 35 40 Min.<br />

10557<br />

Column: Prevail Carbohydrate ES, 5µm, 4.6 x 250mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 15 15 25 25 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column Temp: Ambient<br />

Prevail All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

Carbohydrate ES, 5µm 4.6 x 7.5mm 3 96435<br />

All-Guard Cartridge Holder ea 80101<br />

*All-Guard holder required. Other particle sizes available.<br />

www.discoverysciences.com 47


analytical hplc<br />

Alltech ® Platinum Columns<br />

hplc columns | small molecule<br />

For Challenging Separations<br />

• Unique selectivity<br />

• Better peak shapes with polar analytes<br />

• More separation choices with dual-selectivity<br />

• Excellent stability and reproducibility<br />

• 1.5µm high throughput media for speed and resolution, especially when combined with<br />

Rocket and Expedite hardware<br />

The Platinum Column Advantage<br />

Controlled silica exposure is the difference that makes Platinum columns unique. Instead of thoroughly<br />

covering the silica with bonded phase to hide the silica, the exposure of the silica in Platinum columns is controlled to provide<br />

a dual mode separation with both polar and non-polar sites exposed to your samples. This extends polar selectivity well beyond<br />

what other reversed-phase columns offer and gives separations other columns cannot.<br />

Standard Platinum Columns vs Platinum EPS Columns<br />

Platinum columns come in two varieties offering different levels of silica exposure. Standard Platinum has a moderate silica<br />

exposure and is best used with neutral and moderately polar compounds. Platinum EPS (Extended Polar Selectivity) has a<br />

high level of silica exposure and is best used with compounds containing more than two polar functional groups.<br />

Alltech ® Platinum Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 Silica Spherical 1.5, 3, 5µm 100Å 200m 2 /g 6% Monomeric Yes L1<br />

EPS C18 Silica Spherical 1.5, 3, 5µm 100Å 200m 2 /g 5% Monomeric No L1<br />

C8 Silica Spherical 1.5, 3, 5µm 100Å 200m 2 /g 4% Monomeric Yes L7<br />

EPS C8 Silica Spherical 3, 5µm 100Å 200m 2 /g 2.50% Monomeric No L7<br />

Phenyl Silica Spherical 3, 5µm 100Å 200m 2 /g — Monomeric Yes L11<br />

Cyano Silica Spherical 3, 5µm 100Å 200m 2 /g — Monomeric No L10<br />

Amino (NH2) Silica Spherical 3, 5µm 100Å 200m 2 /g — Monomeric No L8<br />

Silica Silica Spherical 3, 5µm 100Å 200m 2 /g — — — L3<br />

SAX Silica Spherical 3, 5µm* 100Å 200m 2 /g — Monomeric No —<br />

Trying to solve difficult separation problems using typical reversed-phase columns often leads to the same result. Choose Platinum columns<br />

for completely different selectivity. See chart below.<br />

Hydrophobic/Hydrophillic Balance at pH 3 of Various Reversed-Phase HPLC Packings<br />

1.6<br />

1.4<br />

1.2<br />

Platinum<br />

EPS C8<br />

Platinum EPS C18<br />

k’ Amitripyline / k’ Toluene<br />

1<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

Standard<br />

Platinum C8<br />

Typical RP C8<br />

N O T E<br />

Platinum column’s unique selectivity<br />

stands out from the competition.<br />

Standard<br />

Platinum C18<br />

Typical RP C18<br />

0<br />

Typical Polar Embedded<br />

0 1 2 3 4 5 6 7 8<br />

k’ Toluene<br />

Plotting k' values of different compounds (polar vs. nonpolar) demonstrate the unique selectivity of Platinum and Platinum EPS columns,<br />

compared to conventional reversed-phase columns.<br />

48<br />

www.discoverysciences.com


analytical hplc<br />

Reverse Elution Order with Standard<br />

Platinum and Platinum EPS Columns<br />

Often, it’s preferable when minor components elute before,<br />

rather than after, closely retained major components.<br />

1,2<br />

Standard Platinum C18<br />

2<br />

4<br />

0 2 4 6 8 10 12 14 16 Min.<br />

5<br />

Platinum EPS C18<br />

Vasodilators<br />

1<br />

3<br />

4<br />

3<br />

5<br />

8387<br />

1. Pindolol<br />

2. Pentoxifylline<br />

3. Isoxsuprine<br />

4. Nifedipine Degradant<br />

5. Nifedipine<br />

8388<br />

Column: 5µm, 4.6 x 150mm<br />

Mobile Phase: 0.025M KH2PO4, pH 3.0:Methanol (50:50)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

Platinum EPS Columns Have<br />

High Polar Compound Capacity<br />

This is important for early eluting polar compounds which are<br />

often unresolved on conventional reversed-phase columns.<br />

Capacity Factor<br />

Capacity Factors for Platinum EPS C18 Columns<br />

6.00<br />

5.00<br />

4.00<br />

3.00<br />

2.00<br />

1.00<br />

Biphenyl<br />

Amitriptyline<br />

Toluene<br />

Nitrobenzene<br />

Cinnamic Acid<br />

0.00<br />

1 5 10 15 20 25 30 35 40 45<br />

Consecutive Batches<br />

hplc columns | small molecule<br />

Platinum HPLC Columns<br />

Standard<br />

Part No.<br />

Waters ® Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

C18, 1.5µm Rocket 7.0 x 33mm 50527 —<br />

Rocket 7.0 x 53mm 50529 —<br />

C18, 3µm Solvent Reducer 3.0 x 150mm 32794 —<br />

Analytical 4.6 x 100mm 32007 32009<br />

Analytical 4.6 x 150mm 32020 32029<br />

Rocket 7.0 x 33mm 50525 —<br />

Rocket 7.0 x 53mm 50523 —<br />

C18, 5µm Solvent Reducer 3.0 x 150mm 32793 —<br />

Solvent Reducer 3.0 x 250mm 32792 —<br />

Analytical 4.6 x 150mm 32043 32044<br />

Analytical 4.6 x 250mm 32064 32068<br />

EPS C18, 1.5µm Rocket 7.0 x 33mm 50577 —<br />

Rocket 7.0 x 53mm 50579 —<br />

EPS C18, 3µm* Capillary 0.150x 50mm 22300 —<br />

Capillary 0.150x100mm 22430 —<br />

Capillary 0.150x150mm 22431 —<br />

Capillary 0.300x 50mm 22432 —<br />

Capillary 0.300x100mm 22433 —<br />

Capillary 0.300x150mm 22434 —<br />

Solvent Reducer 3.0 x 150mm 32799 —<br />

Analytical 4.6 x 100mm 32158 32161<br />

Analytical 4.6 x 150mm 32183 32184<br />

Rocket 7.0 x 33mm 50575 —<br />

Rocket 7.0 x 53mm 50573 —<br />

EPS C18, 5µm Solvent Reducer 3.0 x 150mm 32806 —<br />

Solvent Reducer 3.0 x 250mm 32802 —<br />

Analytical 4.6 x 150mm 32214 32216<br />

Analytical 4.6 x 250mm 32246 32247<br />

C8, 1.5µm Rocket 7.0 x 53mm 50529 —<br />

C8, 3µm Rocket 7.0 x 33mm 50532 —<br />

C8, 5µm Analytical 4.6 x 150mm 32370 32371<br />

Analytical 4.6 x 250mm 32375 32376<br />

EPS C8, 3µm Analytical 4.6 x 150mm 32415 32416<br />

Rocket 7.0 x 33mm 50583 —<br />

Rocket 7.0 x 53mm 50585 —<br />

EPS C8, 5µm Analytical 4.6 x 150mm 32420 32421<br />

Analytical 4.6 x 250mm 32425 32426<br />

*1.5µm and 5µm particles and other dimensions are available.<br />

Platinum HPLC Columns (continued)<br />

Standard<br />

Part No.<br />

Waters ® Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

Phenyl, 3µm Analytical 4.6 x 150mm 32631 32632<br />

Phenyl, 5µm Analytical 4.6 x 150mm 32636 32637<br />

Analytical 4.6 x 250mm 32641 32642<br />

Cyano, 3µm Rocket 7.0 x 33mm 50593 —<br />

Rocket 7.0 x 53mm 50595 —<br />

Cyano, 5µm Analytical 4.6 x 150mm 32672 32675<br />

Analytical 4.6 x 250mm 32681 32682<br />

Amino, 3µm Analytical 4.6 x 150mm 32706 32707<br />

Rocket 7.0 x 53mm 50545 —<br />

Amino, 5µm Analytical 4.6 x 150mm 32713 32714<br />

Analytical 4.6 x 250mm 32722 32723<br />

Silica, 3µm Analytical 4.6 x 150mm 32535 32536<br />

Silica, 5µm Analytical 4.6 x 150mm 32542 32543<br />

Analytical 4.6 x 250mm 32549 32550<br />

SAX, 3µm Analytical 4.6 x 150mm 32952 32953<br />

SAX, 5µm Analytical 4.6 x 150mm 32944 32946<br />

Analytical 4.6 x 250mm 32943 32945<br />

Platinum Guard Cartridges<br />

Packing i.d. x Length Qty. Part No.<br />

C18 All-Guard, 5µm* 3.0 x 7.5mm 3 99115<br />

4.6 x 7.5mm 3 32606<br />

EPS C18, 3µm<br />

0.150 x 10mm — 22693<br />

Capillary Guard**<br />

0.300 x 10mm — 22694<br />

EPS C18 All-Guard, 5µm* 3.0 x 7.5mm 3 99117<br />

4.6 x 7.5mm 3 32607<br />

C8 All-Guard, 5µm* 4.6 x 7.5mm 3 32612<br />

EPS C8 All-Guard, 5µm* 4.6 x 7.5mm 3 32614<br />

Phenyl All-Guard, 5µm* 4.6 x 7.5mm 3 32619<br />

Cyano All-Guard, 5µm* 4.6 x 7.5mm 3 32620<br />

Amino All-Guard, 5µm* 4.6 x 7.5mm 3 32621<br />

Silica All-Guard, 5µm* 4.6 x 7.5mm 3 32622<br />

SAX All-Guard, 5µm* 4.6 x 7.5mm 3 32787<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

Capillary Guard Cartridge Holder<br />

Guard Holder for 0.100mm and 0.150mm Guards ea GR-3710E<br />

Guard Holder for 0.300mm and 0.500mm Guards ea GR-3710A<br />

*All-Guard holder required.<br />

**1.5µm and 5µm particles and other dimensions are available.<br />

www.discoverysciences.com 49


analytical hplc<br />

hplc columns | small molecule<br />

<strong>Grace</strong>Smart Columns<br />

High Quality HPLC Phases at Exceptional Value<br />

• High purity phases<br />

• Efficient and reproducible separations<br />

• General use selectivity<br />

• Exceptional value<br />

<strong>Grace</strong>Smart HPLC phases use high-purity silica and are monomerically bonded with uniform<br />

coverage. This translates into symmetrical peaks for acids/bases, and predictable reversed-phase<br />

selectivity. Whether routine analysis or new method development, use <strong>Grace</strong>Smart columns to<br />

get premium performance at exceptional value.<br />

Reproducible Methods Start with<br />

Reproducible Columns<br />

Our tightly controlled silica synthesis and bonding keep<br />

capacity factor and selectivity variations to a minimum. The<br />

advanced packing methods deliver consistently high columnto-column<br />

efficiency. Every column is individually tested and<br />

shipped with a quality assurance chromatogram.<br />

best<br />

value<br />

new<br />

<strong>Grace</strong>Smart Phase Specifications<br />

Phase Encapping Surface Area Pore Size Particle Size<br />

C18 TMS, non-polar 220m 2 /g 120Å 3, 5µm<br />

Expect Competitive Performance<br />

Six sigma techniques and lean manufacturing are key to our<br />

cost competitive position, without compromising quality or<br />

performance. <strong>Grace</strong>Smart columns show similiar or better<br />

efficiency and asymmetries for challenging base and acid<br />

components in comparison to industry leading columns.<br />

Capacity Factor<br />

5<br />

4.5<br />

4<br />

3.5<br />

3<br />

2.5<br />

2<br />

1.5<br />

1<br />

0.5<br />

0<br />

1 2 3 4 5 6 7 8 9 10 11 12<br />

Toluene<br />

N-Butylbenzoic Acid<br />

Anisole<br />

Highly Reproducible<br />

Batch<br />

Acetophenone<br />

P-Nitrophenol<br />

Amitriptyline<br />

Consistent batch-to-batch capacity for acidic, basic, and neutral<br />

compounds.<br />

Symmetry Plates / Columns<br />

12,000<br />

10,000<br />

8,000<br />

6,000<br />

4,000<br />

2,000<br />

0<br />

2.5<br />

2<br />

1.5<br />

1<br />

0.5<br />

0<br />

Nicotine<br />

Nicotine<br />

Efficiency<br />

Quinine<br />

Symmetry<br />

Quinine<br />

Diphenhydramine<br />

Diphenhydramine<br />

Competitor 1 C18 Column<br />

Competitor 2 C18 Column<br />

Competitor 3 C18 Column<br />

<strong>Grace</strong>Smart C18 Column<br />

<strong>Grace</strong>Smart columns compare favorably to leading competitor<br />

columns.<br />

Nortriptyline<br />

Nortriptyline<br />

2,4 Dichlorophenoxy Acetic Acid<br />

2,4 Dichlorophenoxy Acetic Acid<br />

2,4 Dichlorophenoxy Propionic Acid<br />

2,4 Dichlorophenoxy Propionic Acid<br />

2,4 Dichlorophenoxy Butyric Acid<br />

2,4 Dichlorophenoxy Butyric Acid<br />

<strong>Grace</strong>Smart RP18 Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 5µm Analytical 4.6 x 150mm 5138812<br />

Analytical 4.6 x 250mm 5138810<br />

Analytical 2.1 x 150mm 5138811<br />

Analytical 2.1 x 250mm 5138813<br />

C18, 3µm Analytical 4.6 x 150mm 5141752<br />

Analytical 4.6 x 100mm 5141753<br />

Analytical 2.1 x 150mm 5141754<br />

Analytical 2.1 x 100mm 5141755<br />

Analytical 2.1 x 50mm 5141756<br />

Analytical 4.6 x 50mm 5141811<br />

50<br />

www.discoverysciences.com


analytical hplc<br />

<strong>Grace</strong>Smart Columns<br />

mAu<br />

6000000<br />

5500000<br />

5000000<br />

4500000<br />

4000000<br />

3500000<br />

3000000<br />

2500000<br />

2000000<br />

1500000<br />

1000000<br />

500000<br />

0<br />

-500000<br />

Amoxicillin (U.S.P.)<br />

0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Min.<br />

<strong>Grace</strong>Smart C18 Column<br />

Luna C18 Column<br />

Inertsil ® ODS-3 Column<br />

Hypersil ® BDS C18 Column<br />

Kromasil ® 100-5 C18 Column<br />

10697<br />

Column: <strong>Grace</strong>Smart C18 Column, 5µm, 4.6 x 250mm<br />

(Part No. 5138810)<br />

Mobile Phase: Isocratic, 0.05N Monobasic Potassium Phosphate<br />

pH 5:Acetonitrile (96:4)<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 230nm<br />

Column Temp: 30°C<br />

Injection Vol: 10µL<br />

3<br />

1<br />

2<br />

4<br />

5<br />

6<br />

0 2 4 6 8 Min.<br />

7<br />

Standards Mix<br />

Ibuprofen (U.S.P.)<br />

1<br />

2<br />

10696<br />

1. Nicotine<br />

2. Quinine<br />

3. Diphenhydramine<br />

4. Nortriptyline<br />

5. 2,4, Dichlorophenoxy Acetic Acid<br />

6. 2,4, Dichlorophenoxy Propionic Acid<br />

7. 2,4, Dichlorophenoxy Butyric Acid<br />

Column: <strong>Grace</strong>Smart RP18, 5μm, 4.6 x 150mm<br />

Mobile Phase: 50% MeCN/50% 50mM, KH2PO4, pH 3 at 35°C<br />

10702<br />

1. Valerophenone<br />

2. Ibuprofen<br />

hplc columns | small molecule<br />

Hypersil ®<br />

BDS<br />

C18<br />

Kromasil ®<br />

100-5<br />

C18<br />

USP <strong>Grace</strong>Smart Luna Inertsil ®<br />

Spec C18 C18 ODS-3<br />

N/A 3.800 4.050 4.988 3.333 3.768<br />

Ret. Time<br />

(min)<br />

Theoretical ≥1700 8543 7216 6230 7049 7680<br />

plates<br />

Tailing ≤2.5 1.015 1.180 1.041 1.034 0.979<br />

Factor<br />

k' 1.1≤k'≤2.8 1.2 1.6 2.3 0.99 1.6<br />

0<br />

2.5 5 7.5 10 12.5 15 17.5 20 Min.<br />

Column: <strong>Grace</strong>Smart C18 Column, 5µm, 4.6 x 150mm<br />

(Part No. 5138812)<br />

Mobile Phase: H2O (adjusted with Phosphoric Acid to a pH of 2.5):<br />

Acetonitrile (65:35)<br />

Flow Rate: 2mL/min<br />

Detector: UV at 214nm<br />

Injection Vol: 5µL<br />

1<br />

2<br />

4<br />

3<br />

Carbamates<br />

5<br />

6<br />

7<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

10739<br />

1. Fenuron<br />

2. Monuron<br />

3. Fluometuron<br />

4. Diuron<br />

5. Methiocarb<br />

6. Linuron<br />

7. Neburon<br />

Column: <strong>Grace</strong>Smart C18 Column, 5µm, 4.6 x 150mm<br />

(Part No. 5138812)<br />

Mobile Phase: A: 0.025M KH2PO4, pH 3.2 B: Acetonitrile<br />

Gradient: Time: 0 20<br />

%B: 30 60<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 240nm<br />

Injection Vol: 10µL<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

0 2 4 6 8 10 12 14 Min.<br />

Column:<br />

10733<br />

1. Ascorbic Acid<br />

2. Nicotinic Acid<br />

3. Pyridoxamine<br />

4. Niacinamide<br />

5. Folic Acid<br />

6. Vitamin B12<br />

7. Riboflavin<br />

<strong>Grace</strong>Smart C18 Column, 5μm, 4.6 x 150mm<br />

(Part No. 5138812)<br />

Mobile Phase: A: 0.1M NH4H2PO4 Buffer, pH 4.5<br />

B: Acetonitrile<br />

Gradient: Time: 0 4 10 15<br />

%B: 5 5 40 40<br />

Flow Rate:<br />

Detector:<br />

Injection Vol:<br />

Water Soluble Vitamins<br />

1.0mL/min<br />

UV at 254nm<br />

2μL<br />

www.discoverysciences.com 51


analytical hplc<br />

hplc columns | small molecule<br />

<strong>Grace</strong>Alpha Columns (Patent Pending)<br />

A New Silica Generation<br />

• High-porosity surface increases mass transfer and results in increased column<br />

efficiencies and loading capacity<br />

• Dense core and highly spherical shape yields mechanically robust particle<br />

• Proprietary bonding technology gives unique selectivity and increased resolution<br />

• Ideally suited for scale up to prep applications<br />

Extreme Porosity<br />

High-porosity exterior increases mass transfer leading to higher<br />

efficiencies and superior loading capacity.<br />

The high-porosity structure adds an elastic quality to the silica surface<br />

allowing the particles to pack tighter yielding higher efficiencies. It also<br />

stabilizes the packed bed preventing voids.<br />

Dense Inner Core<br />

new<br />

Dense core provides exceptional strength. Typically the high-porosity<br />

structure would result in a weak particle prone to breaking, but the<br />

<strong>Grace</strong>Alpha particle combines the high porosity outer region with a dense<br />

inner core that results in a particle that resists breaking and forming fines<br />

that contribute to high backpressures.<br />

<strong>Grace</strong>Alpha Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 Silica Spherical 5, 10, 15, 20µm 120Å 325m 2 /g 15% Monomeric Yes L1<br />

C8 Silica Spherical 5, 10, 15, 20µm 120Å 325m 2 /g 10% Monomeric — L7<br />

Silica Silica Spherical 5, 10, 15, 20µm 120Å 325m 2 /g — Monomeric — L3<br />

High Level of Resolution<br />

<strong>Grace</strong>Alpha offers resolution advantages due to its higher<br />

mass transfer and optimized C18 and C8 bonding chemistry.<br />

Adsorbence<br />

Adsorbence<br />

1.0<br />

0.5<br />

0<br />

1.0<br />

0.5<br />

0<br />

0<br />

0<br />

Crude 20-AA Synthetic Peptide<br />

from Biopeptide Co., Inc.<br />

Better resolution<br />

of closely<br />

eluting impurities<br />

<strong>Grace</strong>Alpha Column 5µm<br />

5<br />

Competitor 4µm<br />

5<br />

10 15 19.99 Min.<br />

10 15 19.99 Min.<br />

<strong>Grace</strong>Alpha Columns<br />

Packing i.d. x Length Part No.<br />

C18, 5µm 4.6 x 150mm 5140743<br />

4.6 x 250mm 5140702<br />

C18, 10µm 4.6 x 150mm 5140744<br />

4.6 x 250mm 5140701<br />

C18, 15µm 4.6 x 150mm 5141058<br />

4.6 x 250mm 5141059<br />

C8, 5µm 4.6 x 150mm 5140740<br />

4.6 x 250mm 5140704<br />

C8, 10µm 4.6 x 150mm 5140742<br />

4.6 x 250mm 5140703<br />

C8, 15µm 4.6 x 150mm 5141055<br />

4.6 x 250mm 5141057<br />

Silica, 5µm 4.6 x 150mm 5140740<br />

4.6 x 250mm 5140704<br />

Silica, 10µm 4.6 x 150mm 5140742<br />

4.6 x 250mm 5140703<br />

Silica, 15µm 4.6 x 150mm 5141055<br />

4.6 x 250mm 5141057<br />

Columns: All C18 4.6 x 250mm<br />

Mobile Phase: A: 0.1% TFA in Water B: 0.1% TFA in Acetonitrile<br />

Gradient: Time: 0 20<br />

%B: 20 40<br />

Flow Rate: 1.0mL/min<br />

The target peptide is better resolved from impurities, with 33% higher<br />

recovery, on the <strong>Grace</strong>Alpha column.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

52<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Brava Columns<br />

If You Like Hypersil ® BDS, Try This Lower-Cost Alternative<br />

• BDS phases for acids, bases, and neutrals<br />

• ODS phases for non-polars and lipophilics<br />

Medium-sized pores are ideal for resolution of small- to medium-sized compounds,<br />

while its less-retentive nature means less mobile phase consumption.<br />

Brava HPLC Columns<br />

Packing i.d. x Length Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

C18 BDS, 3µm 4.6 x 100mm 50910 50911<br />

4.6 x 150mm 50912 50913<br />

C18 BDS, 5µm 4.6 x 150mm 50914 50915<br />

4.6 x 250mm 50916 50917<br />

C18 ODS, 3µm 4.6 x 100mm 50957 50959<br />

4.6 x 150mm 50961 50963<br />

C18 ODS, 5µm 4.6 x 150mm 50965 50967<br />

4.6 x 250mm 50969 50971<br />

C8 BDS, 3µm 4.6 x 100mm 50918 50919<br />

4.6 x 150mm 50920 50921<br />

C8 BDS, 5µm 4.6 x 150mm 50922 50923<br />

4.6 x 250mm 50924 50925<br />

C8, 3µm 4.6 x 100mm 50939 50943<br />

4.6 x 150mm 50945 50947<br />

C8, 5µm 4.6 x 150mm 50949 50951<br />

4.6 x 250mm 50953 50955<br />

Phenyl, 5µm 4.6 x 150mm 50978 50979<br />

4.6 x 250mm 50981 50983<br />

Cyano BDS, 5µm 4.6 x 150mm 50926 50927<br />

4.6 x 250mm 50928 50929<br />

Cyano, 5µm 4.6 x 150mm 50973 50975<br />

4.6 x 250mm 50976 50977<br />

Amino, 5µm 4.6 x 150mm 50930 50931<br />

4.6 x 250mm 50933 50934<br />

Silica, 5µm 4.6 x 150mm 50935 50936<br />

4.6 x 250mm 50937 50938<br />

best<br />

value<br />

Brava Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 BDS Silica Spherical 3, 5µm 145Å 185m 2 /g 8.5% Monomeric Yes L1<br />

C18 ODS Silica Spherical 3, 5µm 130Å 195m 2 /g 8.5% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5µm 130Å 195m 2 /g 6% Monomeric Yes L7<br />

C8 BDS Silica Spherical 3, 5µm 145Å 185m 2 /g 5.5% Monomeric Yes L7<br />

Phenyl Silica Spherical 5µm 130Å 195m 2 /g — Monomeric No L11<br />

Cyano Silica Spherical 5µm 130Å 195m 2 /g — Monomeric No L10<br />

Cyano BDS Silica Spherical 5µm 145Å 185m 2 /g — Monomeric No L10<br />

Amino (NH2) Silica Spherical 5µm 130Å 195m 2 /g — Monomeric No L8<br />

Silica Silica Spherical 5µm 130Å 195m 2 /g — — No L3<br />

2<br />

1<br />

0 2<br />

Metal Chelator<br />

4 Min.<br />

Column: Brava C18 BDS, 5µm, 4.6 x 150mm<br />

(Part No. 50914)<br />

Mobile Phase: Acetonitrile:50mM KH2PO4 pH 3 (50:50)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

10473<br />

1. Pyridine<br />

2. 2, 2’ Dipyridyl<br />

hplc columns | small molecule<br />

Brava All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

C18 BDS, 5µm 4.6 x 7.5mm 3 96472<br />

C18 ODS, 5µm 4.6 x 7.5mm 3 96477<br />

C8 BDS, 5µm 4.6 x 7.5mm 3 96473<br />

C8, 5µm 4.6 x 7.5mm 3 96478<br />

Phenyl, 5µm 4.6 x 7.5mm 3 96480<br />

Cyano BDS, 5µm 4.6 x 7.5mm 3 96474<br />

Cyano, 5µm 4.6 x 7.5mm 3 96479<br />

Amino, 5µm 4.6 x 7.5mm 3 96475<br />

Silica, 5µm 4.6 x 7.5mm 3 96476<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

www.discoverysciences.com 53


analytical hplc<br />

hplc columns | small molecule<br />

Alltech ® Alltima Introduction<br />

High-Quality General-Purpose HPLC Columns<br />

• Extensive collection of published applications<br />

• Well suited for microbore applications, stable in popular microbore mobile phases<br />

• Acid and base deactivated symmetrical peaks<br />

• Polymerically bonded and double-endcapped for long column lifetimes<br />

• Analyze acids, bases, and neutrals in one run<br />

• Full range of column dimensions, from microbore to preparative<br />

Alltima Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 Silica Spherical 3, 5, 10µm 100Å 340m 2 /g 16% Polymeric Yes L1<br />

C18 LL Silica Spherical 5µm 100Å 340m 2 /g 9% Polymeric Yes L1<br />

C8 Silica Spherical 3, 5, 10µm 100Å 340m 2 /g 9% Polymeric Yes L7<br />

Phenyl Silica Spherical 3, 5µm 100Å 340m 2 /g 7.5% Polymeric Yes L11<br />

Cyano Silica Spherical 3, 5µm 100Å 340m 2 /g — Polymeric Yes L10<br />

Amino (NH2) Silica Spherical 3, 5µm 100Å 340m 2 /g — Polymeric No L8<br />

Silica Silica Spherical 3, 5, 10µm 100Å 340m 2 /g — — — L3<br />

1<br />

2<br />

3<br />

4<br />

Basic Drugs<br />

8193<br />

1. Procainamide<br />

2. Acetaminophen<br />

3. Theophylline<br />

4. Caffeine<br />

best<br />

seller<br />

1<br />

2<br />

Antibacterials<br />

3<br />

8764<br />

1. Oxytetracycline<br />

Dihydrate<br />

2. Tetracycline HCL<br />

3. Meclocycline<br />

Sulfosalicylate Salt<br />

0 5 10 15 Min.<br />

Column: Alltima C8, 5µm, 4.6 x 150mm<br />

Mobile Phase: Methanol:50mM KH2PO4, pH 3.0 (20:80)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

0 2 4 6 8 10 Min.<br />

Column: Alltima C18, 3µm, 4.6 x 100mm<br />

Mobile Phase: A: 50mM KH2PO4, pH 3.0 B: CH3CN<br />

Gradient: Time: 0 10<br />

%B: 15 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Natural Products<br />

8887<br />

4<br />

Antihistamines<br />

7232<br />

1<br />

2<br />

3<br />

4<br />

1. Naringin<br />

2. Neohesperidin<br />

3. Myricetin<br />

4. Quercetin<br />

5. Naringenin<br />

6. Kaempferol<br />

5 6<br />

1<br />

2<br />

3<br />

5<br />

1. Tripelennamine<br />

2. Triprolidine<br />

3. Cyclizine<br />

4. Chlorcyclizine<br />

5. Meclizine<br />

0 5<br />

10 15 Min.<br />

Column: Alltima C18, 3µm, 4.6 x 100mm<br />

Mobile Phase: A: 50mM KH2PO4, pH 2.5 B: CH3CN<br />

Gradient: Time: 0 15<br />

%B: 20 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 280nm<br />

0 5 10 15 20 25 Min.<br />

Column: Alltima C18, 5µm, 4.6 x 250mm<br />

Mobile Phase: A: 50mM KH2PO4, pH 3.2 B: CH3CN<br />

Gradient: Time: 0 5 20<br />

%B: 25 25 70<br />

Flow Rate: 1.3mL/min<br />

Detector: UV at 220nm<br />

54<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Alltima Reversed-Phase Columns<br />

1<br />

0 1<br />

2<br />

7<br />

4,5 6<br />

3<br />

2<br />

Taxol ® and Related Taxanes in Yew<br />

(taxus brevifolia)<br />

3<br />

8 9<br />

1011<br />

12 13<br />

4<br />

5 6<br />

7<br />

1. 10-deacetylbaccatin III<br />

2. Baccatin III<br />

3. 7-xylosyl-10-deacetyltaxol B<br />

4. Taxinine M<br />

5. 7-xylosyl-10-deacetyltaxol<br />

6. 7-xylosyl-10-deacetyltaxol C<br />

7. 10-deacetyltaxol<br />

8. 7-xylosyltaxol<br />

9. Cephalomannine (Taxol ® B)<br />

10. 7-epi-10-deacetyltaxol<br />

11. Taxol ®<br />

12. Taxol ® C<br />

13. 7-epitaxol<br />

8 Min.<br />

Column: Alltima Phenyl Rocket, 3µm, 7 x 53mm<br />

Mobile Phase: 0.05% TFA in H2O:MeOH:CH3CN (50:19:31)<br />

Flow Rate: 2.5mL/min<br />

Detector: UV at 230nm<br />

123<br />

4<br />

Anticonvulsants<br />

0 4 8 12 16 20 Min.<br />

5<br />

Column: Alltima Phenyl, 5µm, 4.6 x 250mm<br />

Mobile Phase: A: H2O B: CH3CN<br />

Gradient: Time: 0 20 25 30<br />

%B: 15 60 60 15<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 254nm<br />

6<br />

9221<br />

7233<br />

1. Ethotoin<br />

2. Phenobarbital<br />

3. Methsuximide<br />

4. Mephenytoin<br />

5. Carbamazepine<br />

6. Diazepam<br />

Alltima All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

C18, 5µm 2.1 x 7.5mm 3 96680<br />

3.0 x 7.5mm 3 96361<br />

4.6 x 7.5mm 3 96080<br />

C18-LL, 5µm 2.1 x 7.5mm 3 96432<br />

3.0 x 7.5mm 3 96433<br />

4.6 x 7.5mm 3 96285<br />

C8, 5µm 2.1 x 7.5mm 3 96441<br />

3.0 x 7.5mm 3 96362<br />

4.6 x 7.5mm 3 96081<br />

Phenyl, 5µm 2.1 x 7.5mm 3 96442<br />

3.0 x 7.5mm 3 96445<br />

4.6 x 7.5mm 3 96082<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

Alltima HPLC Reversed-Phase Columns<br />

Standard<br />

Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

C18, 3µm Microbore 1.0 x 100mm 43853 —<br />

Microbore 1.0 x 150mm 43864 —<br />

Expedite MS 2.1 x 10mm 43836 —<br />

Expedite MS 2.1 x 20mm 43803 —<br />

Microbore 2.1 x 50mm 43849 —<br />

Microbore 2.1 x 100mm 43821 —<br />

Microbore 2.1 x 150mm 43852 —<br />

Solvent Reducer 3.0 x 150mm 81143 —<br />

Expedite MS 4.6 x 10mm 43837 —<br />

Expedite MS 4.6 x 20mm 43851 —<br />

Analytical 4.6 x 50mm 81412 —<br />

Analytical 4.6 x 100mm 81382 81383<br />

Analytical 4.6 x 150mm 81387 81388<br />

Rocket 7 x 33mm 50603 —<br />

Rocket 7 x 53mm 50605 —<br />

C18, 5µm Microbore 1.0 x 150mm 88384 —<br />

Microbore 1.0 x 250mm 88385 —<br />

Microbore 2.1 x 150mm 88370 —<br />

Microbore 2.1 x 250mm 88371 —<br />

Solvent Reducer 3.0 x 150mm 81140 —<br />

Solvent Reducer 3.0 x 250mm 81142 —<br />

Analytical 4.6 x 150mm 88052 88053<br />

Analytical 4.6 x 250mm 88056 88057<br />

C18, 10µm Analytical 4.6 x 250mm 88307 88308<br />

C18-LL, 5µm Microbore 1.0 x 150mm 88390 —<br />

Microbore 1.0 x 250mm 88391 —<br />

Microbore 2.1 x 150mm 88388 —<br />

Microbore 2.1 x 250mm 88389 —<br />

Solvent Reducer 3.0 x 150mm 81144 —<br />

Solvent Reducer 3.0 x 250mm 81145 —<br />

Analytical 4.6 x 150mm 88069 88082<br />

Analytical 4.6 x 250mm 88099 88235<br />

C8, 3µm Analytical 4.6 x 50mm 81413 —<br />

Analytical 4.6 x 100mm 81392 81393<br />

Analytical 4.6 x 150mm 81397 81398<br />

Rocket 7 x 33mm 50607 —<br />

Rocket 7 x 53mm 50609 —<br />

C8, 5µm Microbore 1.0 x 150mm 88394 —<br />

Microbore 1.0 x 250mm 88395 —<br />

Microbore 2.1 x 150mm 88372 —<br />

Microbore 2.1 x 250mm 88373 —<br />

Solvent Reducer 3.0 x 150mm 81146 —<br />

Analytical 4.6 x 150mm 88072 88073<br />

Analytical 4.6 x 250mm 88076 88077<br />

C8, 10µm Analytical 4.6 x 250mm 88317 88318<br />

Phenyl, 3µm Microbore 1.0 x 100mm 43892 —<br />

Microbore 1.0 x 150mm 43854 —<br />

Expedite MS 2.1 x 10mm 43809 —<br />

Expedite MS 2.1 x 20mm 43865 —<br />

Microbore 2.1 x 50mm 43835 —<br />

Microbore 2.1 x 100mm 43866 —<br />

Microbore 2.1 x 150mm 43813 —<br />

Expedite MS 4.6 x 10mm 43883 —<br />

Expedite MS 4.6 x 20mm 43822 —<br />

Analytical 4.6 x 50mm 81178 —<br />

Analytical 4.6 x 100mm 81181 88184<br />

Analytical 4.6 x 150mm 81188 81191<br />

Phenyl, 5µm Solvent Reducer 3.0 x 150mm 81147 —<br />

Analytical 4.6 x 150mm 88087 88088<br />

Analytical 4.6 x 250mm 88092 88093<br />

hplc columns | small molecule<br />

www.discoverysciences.com 55


analytical hplc<br />

Alltech ® Alltima C18 Validation Kits<br />

Alltima columns have the batch-to-batch and column-tocolumn<br />

reproducibility required for method development. Each<br />

kit includes three columns made from three different batches<br />

of Alltima C18.<br />

Alltima is Stable and Reproducible<br />

Initial Separation<br />

7553<br />

hplc columns | small molecule<br />

Alltima C18 Validation Kits<br />

Description Includes: i.d. x Length Part No.<br />

C18, 3µm 3 columns from 3 different batches 4.6 x 100mm 11350<br />

C18, 5µm 3 columns from 3 different batches 4.6 x 150mm 11541<br />

C18, 5µm 3 columns from 3 different batches 4.6 x 250mm 11543<br />

Alltech ® Alltima <br />

Normal-Phase Columns<br />

Alltima HPLC Normal-Phase Columns<br />

Standard<br />

Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

Cyano, 3µm Analytical 4.6 x 50mm 81179 —<br />

Analytical 4.6 x 100mm 81182 81186<br />

Analytical 4.6 x 150mm 81189 81192<br />

Cyano, 5µm Analytical 4.6 x 150mm 88180 88182<br />

Analytical 4.6 x 250mm 88189 88191<br />

Amino, 3µm Analytical 4.6 x 50mm 81180 —<br />

Analytical 4.6 x 100mm 81183 81187<br />

Analytical 4.6 x 150mm 81190 81193<br />

Amino, 5µm Analytical 4.6 x 150mm 88205 88207<br />

Analytical 4.6 x 250mm 88217 88218<br />

Silica, 3µm Microbore 1.0 x 100mm 43824 —<br />

Microbore 1.0 x 150mm 43855 —<br />

Expedite MS 2.1 x 10mm 43891 —<br />

Expedite MS 2.1 x 20mm 43801 —<br />

Microbore 2.1 x 50mm 43876 —<br />

Microbore 2.1 x 100mm 43823 —<br />

Microbore 2.1 x 150mm 43884 —<br />

Expedite MS 4.6 x 10mm 43889 —<br />

Expedite MS 4.6 x 20mm 43886 —<br />

Analytical 4.6 x 50mm 81414 —<br />

Analytical 4.6 x 100mm 81404 81405<br />

Analytical 4.6 x 150mm 81409 81410<br />

Silica, 5µm Analytical 4.6 x 150mm 88123 88124<br />

Analytical 4.6 x 250mm 88171 88172<br />

Silica, 10µm Analytical 4.6 x 250mm 88327 88328<br />

Alltima All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

Cyano, 5µm 4.6 x 7.5mm 3 96084<br />

Amino, 5µm 4.6 x 7.5mm 3 96085<br />

Silica, 5µm 2.1 x 7.5mm 3 96450<br />

4.6 x 7.5mm 3 96083<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

1<br />

2<br />

4<br />

5<br />

0 5 10 15 20 25 30 35 40 45 50 55 Min.<br />

After 500 Hours of Washing at 60°C<br />

1<br />

2<br />

0 5 10 15 20 25 30 35 40 45 50 55 Min.<br />

Column: Alltima C18, 5µm, 4.6 x 150mm<br />

Mobile Phase: A: Water:Acetonitrile:TFA (95:5:0.1)<br />

B: Water:Acetonitrile:TFA (25:75:0.1)<br />

Gradient: Time: 0 60<br />

% B: 5 30<br />

Flow Rate: 1mL/min<br />

Detector: UV at 220nm<br />

Column capacity and selectivity remained constant after washing an<br />

Alltima C18 column for 500 hours with 0.5% TFA:Acetonitrile (50:50)<br />

at 60°C.<br />

3<br />

3<br />

4<br />

5<br />

7554<br />

1. Gly-Tyr<br />

2. Val-Tyr-Val<br />

3. Met-Enkephalin<br />

4. Leu-Enkephalin<br />

5. Angiotensin II<br />

tech tip<br />

Want high throughput on a conventional (non-ultra<br />

high-pressure) system?<br />

Choose the Rocket column format—no modifications<br />

necessary to your existing HPLC system. Choose Expedite<br />

columns for low volume and microbore systems. See page 31 for<br />

more explanation of the Rocket and Expedite formats.<br />

56<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Apollo Columns<br />

Economical, High Performance Columns<br />

• Easy scale-up from analytical to prep<br />

• Extended pH stability—1.5 to 10.5<br />

Batch-tested Apollo HPLC columns use high purity, basedeactivated<br />

silica for powerful separations at an economical<br />

price. They are ideal for educational labs or for method<br />

development.<br />

Apollo Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 Silica Spherical 5µm 100Å 340m 2 /g 15% Monomeric Yes L1<br />

C8 Silica Spherical 5µm 100Å 340m 2 /g 9% Monomeric Yes L7<br />

Phenyl Silica Spherical 5µm 100Å 340m 2 /g 8% Monomeric Yes L11<br />

Silica Silica Spherical 5µm 100Å 340m 2 /g — — — L3<br />

Apollo HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 5µm Analytical 4.6 x 150mm 36505<br />

Analytical 4.6 x 250mm 36511<br />

C8, 5µm Analytical 4.6 x 150mm 36506<br />

Analytical 4.6 x 250mm 36512<br />

Phenyl, 5µm Analytical 4.6 x 150mm 36538<br />

Analytical 4.6 x 250mm 36544<br />

Silica, 5µm Analytical 4.6 x 150mm 36507<br />

Analytical 4.6 x 250mm 36513<br />

best<br />

value<br />

Apollo All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

C18, 5µm 4.6 x 7.5mm 3 96454<br />

C8, 5µm 4.6 x 7.5mm 3 96463<br />

Phenyl, 5µm 4.6 x 7.5mm 3 96430<br />

Silica, 5µm 4.6 x 7.5mm 3 96419<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

hplc columns | small molecule<br />

Alltech ® Econosphere Columns<br />

• Low-cost columns for common chromatography applications<br />

• Acid-washed for low metal content<br />

• Easy scale-up from analytical to prep<br />

Econosphere Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 Silica Spherical 3, 5, 10µm 80Å 200m 2 /g 10% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5, 10µm 80Å 200m 2 /g 5% Monomeric Yes L7<br />

Cyano Silica Spherical 5µm 80Å 200m 2 /g — Monomeric Yes L10<br />

Amino (NH2) Silica Spherical 5µm 80Å 200m 2 /g — Polymeric Yes L8<br />

Silica Silica Spherical 3, 5, 10µm 80Å 200m 2 /g — — No L3<br />

Econosphere HPLC Columns<br />

Standard<br />

Part No.<br />

Waters ®<br />

Part No.<br />

Packing Format i.d. x Length<br />

C18, 3µm Analytical 4.6 x 50mm 70153 70156<br />

Analytical 4.6 x 100mm 70154 70157<br />

Analytical 4.6 x 150mm 70155 70158<br />

Rocket 7 x 33mm 50673 —<br />

Rocket 7 x 53mm 50675 —<br />

C18, 5µm Analytical 4.6 x 150mm 70065 70070<br />

Analytical 4.6 x 250mm 70066 70071<br />

C8, 3µm Analytical 4.6 x 50mm 70165 70168<br />

Analytical 4.6 x 100mm 70166 70169<br />

Analytical 4.6 x 150mm 70167 70170<br />

C8, 5µm Analytical 4.6 x 150mm 70085 70090<br />

Analytical 4.6 x 250mm 70086 —<br />

Cyano, 5µm Analytical 4.6 x 150mm 70025 70030<br />

Analytical 4.6 x 250mm 70026 70031<br />

Econosphere HPLC Columns (continued)<br />

Standard<br />

Part No.<br />

Waters ®<br />

Part No.<br />

Packing Format i.d. x Length<br />

Amino, 5µm Analytical 4.6 x 150mm 70045 70050<br />

Analytical 4.6 x 250mm 70046 70051<br />

Silica, 3µm Analytical 4.6 x 50mm 70177 70180<br />

Analytical 4.6 x 100mm 70178 70181<br />

Analytical 4.6 x 150mm 70179 70182<br />

Silica, 5µm Analytical 4.6 x 150mm 70005 70010<br />

Analytical 4.6 x 250mm 70006 70011<br />

Econosphere All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

C18 4.6 x 7.5mm 3 96121<br />

C8 4.6 x 7.5mm 3 96122<br />

Cyano 4.6 x 7.5mm 3 96123<br />

Amino 4.6 x 7.5mm 3 96124<br />

Silica 4.6 x 7.5mm 3 96125<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*Guard holder required.<br />

www.discoverysciences.com 57


analytical hplc<br />

Alltech ® Adsorbosphere Columns<br />

• Reliable performance from rugged, reproducible phases<br />

High temperature bonding for exceptional surface coverage, stability, and reproducibility.<br />

Adsorbosphere columns are the workhorses of any chromatography lab. Choose from<br />

four varieties:<br />

hplc columns | small molecule<br />

Adsorbosphere has a moderate carbon load for common applications.<br />

Adsorbosphere HS has a larger surface area and higher carbon load for stronger retention of hydrophobic compounds.<br />

Adsorbosphere UHS has the largest surface area and highest carbon load for the highest resolution of hydrophobic<br />

compounds.<br />

Adsorbosphere XL is a lower-cost, larger pore alternative. C18-B separates strongly basic analytes more efficiently then<br />

standard C18.<br />

Adsorbosphere Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

Adsorbosphere C18 Silica Spherical 3, 5, 10µm 80Å 200m 2 /g 12% Monomeric Yes L1<br />

Adsorbosphere C18 HS Silica Spherical 3, 5µm 60Å 350m 2 /g 20% Monomeric Yes L1<br />

Adsorbosphere C18 UHS Silica Spherical 5, 10µm 60Å 500m 2 /g 30% Monomeric Yes L1<br />

Adsorbosphere C8 Silica Spherical 5µm 80Å 200m 2 /g 8% Monomeric Yes L7<br />

Adsorbosphere Phenyl Silica Spherical 5µm 80Å 200m 2 /g 5% Monomeric Yes L11<br />

Adsorbosphere Cyano Silica Spherical 5µm 80Å 200m 2 /g — Monomeric Yes L10<br />

Adsorbosphere Cyano-AQ Silica Spherical 5µm 120Å 170m 2 /g — Polymeric No L10<br />

Adsorbosphere Amino (NH2) Silica Spherical 3, 5µm 80Å 200m 2 /g — Polymeric No L8<br />

Adsorbosphere Silica Silica Spherical 5µm 80Å 200m 2 /g — — — L3<br />

Adsorbosphere SAX Silica Spherical 5µm 80Å 200m 2 /g — Monomeric — —<br />

Adsorbosphere SCX Silica Spherical 5µm 80Å 200m 2 /g — Monomeric Yes —<br />

Adsorbosphere XL C18 Silica Spherical 3, 5µm 90Å 200m 2 /g 11% Monomeric Yes L1<br />

Adsorbosphere XL C18-B Silica Spherical 5µm 90Å 200m 2 /g 12% Monomeric Yes L1<br />

Adsorbosphere XL C8 Silica Spherical 3, 5µm 90Å 200m 2 /g 6% Monomeric Yes L7<br />

Adsorbosphere XL C1 (TMS) Silica Spherical 5µm 90Å 200m 2 /g — Monomeric Yes L13<br />

Adsorbosphere XL Silica Silica Spherical 5µm 90Å 200m 2 /g — — — L3<br />

Adsorbosphere XL SAX Silica Spherical 5, 10µm 90Å 200m 2 /g — Monomeric Yes —<br />

Adsorbosphere XL SCX Silica Spherical 5, 10µm 90Å 200m 2 /g — Monomeric Yes —<br />

0 10 20 30 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Column Temp:<br />

Vitamins D2 & D3<br />

1<br />

2<br />

5401<br />

1. Vitamin D2<br />

2. Vitamin D3<br />

Adsorbosphere UHS C18, 5µm, 4.6 x 150mm<br />

(Part No. 288118)<br />

80% Acetonitrile 20% Methanol<br />

1.5mL/min<br />

UV at 254nm<br />

Ambient<br />

Adsorbosphere HPLC Columns<br />

Standard<br />

Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

C18, 3µm Analytical 4.6 x 100mm 287092 287093<br />

Rocket 7 x 33mm 50623 —<br />

Rocket 7 x 53mm 50625 —<br />

C18, 5µm Analytical 4.6 x 150mm 287072 287073<br />

Analytical 4.6 x 250mm 287062 287063<br />

C18, 10µm Analytical 4.6 x 250mm 287052 287053<br />

C8, 5µm Analytical 4.6 x 150mm 287122 287123<br />

Analytical 4.6 x 250mm 287112 287113<br />

Phenyl, 5µm Analytical 4.6 x 150mm 287532 287533<br />

Analytical 4.6 x 250mm 287542 287543<br />

Cyano, 5µm Analytical 4.6 x 150mm 287202 287203<br />

Cyano-AQ, 5µm Analytical 4.6 x 150mm 50005 50035<br />

Analytical 4.6 x 250mm 500050 500060<br />

Amino, 3µm Analytical 4.6 x 150mm 287282 287283<br />

Amino, 5µm Analytical 4.6 x 250mm 287242 287243<br />

Silica, 5µm Analytical 4.6 x 250mm 287012 287013<br />

SAX, 5µm Analytical 4.6 x 250mm 287512 287513<br />

SCX, 5µm Analytical 4.6 x 250mm 287472 287473<br />

Adsorbosphere HS HPLC Columns<br />

Standard<br />

Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

C18 HS, 3µm Analytical 4.6 x 100mm 28780 28781<br />

Analytical 4.6 x 150mm 28786 28787<br />

C18 HS, 5µm Analytical 4.6 x 150mm 28817 28818<br />

Analytical 4.6 x 250mm 28821 28822<br />

58<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Adsorbosphere <br />

Columns (continued)<br />

Adsorbosphere UHS HPLC Columns<br />

Adsorbosphere XL HPLC Columns<br />

Standard<br />

Part No.<br />

Standard<br />

Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

C18 UHS, 5µm Analytical 4.6 x 150mm 288118 288119<br />

C18 UHS, 10µm Analytical 4.6 x 250mm 288133 288134<br />

Waters ®<br />

Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

XL C18, 3µm Analytical 4.6 x 100mm 20237 20286<br />

Analytical 4.6 x 150mm 20381 20394<br />

Rocket 7 x 33mm 50633 —<br />

Rocket 7 x 53mm 50635 —<br />

XL C18, 5µm Analytical 4.6 x 150mm 20390 20462<br />

Analytical 4.6 x 250mm 20552 20579<br />

XL C18-B, 5µm Analytical 4.6 x 150mm 20548 20344<br />

Analytical 4.6 x 250mm 20247 20627<br />

XL C8, 3µm Analytical 4.6 x 150mm 20320 20203<br />

XL C8, 5µm Analytical 4.6 x 150mm 20676 20607<br />

Analytical 4.6 x 250mm 20383 20460<br />

XL C1, 5µm Analytical 4.6 x 150mm 20386 20452<br />

Analytical 4.6 x 250mm 20628 20636<br />

XL Silica, 5µm Analytical 4.6 x 150mm 20365 20398<br />

Analytical 4.6 x 250mm 20256 20654<br />

XL SAX, 5µm Analytical 4.6 x 150mm 20538 20318<br />

Analytical 4.6 x 250mm 20550 20561<br />

XL SAX, 10µm Analytical 4.6 x 250mm 20314 20303<br />

XL SCX, 5µm Analytical 4.6 x 150mm 20525 20531<br />

Analytical 4.6 x 250mm 20545 20564<br />

XL SCX, 10µm Analytical 4.6 x 250mm 20719 20684<br />

Alltech ® Allsphere Columns<br />

Try Alltech’s lower cost Allsphere columns as a replacement<br />

for Spherisorb ® columns. If you are not satisfied with<br />

Allsphere as a direct replacement for your Spherisorb ®<br />

applications, we will refund your money.<br />

Allsphere HPLC Columns<br />

Standard<br />

Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

Packing<br />

i.d. x Length<br />

ODS-1, 5µm 4.6 x 150mm 778441 778443<br />

4.6 x 250mm 778364 778357<br />

ODS-2, 3µm 4.6 x 100mm 778487 778489<br />

4.6 x 150mm 778558 778560<br />

ODS-2, 5µm 4.6 x 150mm 778545 778547<br />

4.6 x 250mm 778736 778738<br />

C8, 3µm 4.6 x 100mm 778561 778563<br />

4.6 x 150mm 778609 778611<br />

C8, 5µm 4.6 x 150mm 778571 778573<br />

4.6 x 250mm 778744 778746<br />

C6, 5µm 4.6 x 150mm 778211 778217<br />

4.6 x 250mm 778223 778224<br />

Phenyl, 5µm 4.6 x 150mm 778689 778691<br />

4.6 x 250mm 778752 778754<br />

Cyano, 5µm 4.6 x 150mm 778713 778715<br />

4.6 x 250mm 778361 778362<br />

Amino, 5µm 4.6 x 150mm 778739 778741<br />

4.6 x 250mm 778371 778372<br />

Silica, 3µm 4.6 x 100mm 778382 778383<br />

4.6 x 150mm 778554 778556<br />

Silica, 5µm 4.6 x 150mm 778389 778391<br />

4.6 x 250mm 778376 778377<br />

SAX, 5µm 4.6 x 250mm 778765 778767<br />

SCX, 5µm 4.6 x 250mm 778188 778189<br />

hplc columns | small molecule<br />

Adsorbosphere All-Guard Cartridges*<br />

Packing i.d.x Length Qty. Part No.<br />

Amino, 5µm 4.6 x 7.5mm 3 96044<br />

C18, 5µm 4.6 x 7.5mm 3 96041<br />

C18 HS, 5µm 4.6 x 7.5mm 3 96079<br />

C18 UHS, 5µm 4.6 x 7.5mm 3 82181<br />

C8, 5µm 4.6 x 7.5mm 3 96042<br />

Cyano, 5µm 4.6 x 7.5mm 3 96047<br />

Cyano-AQ, 5µm 4.6 x 7.5mm 3 96048<br />

Phenyl, 5µm 4.6 x 7.5mm 3 96045<br />

Silica, 5µm 4.6 x 7.5mm 3 96046<br />

SAX, 5µm 4.6 x 7.5mm 3 96049<br />

SCX, 5µm 4.6 x 7.5mm 3 96075<br />

XL C18, 5µm 4.6 x 7.5mm 3 96088<br />

XL C18-B, 5µm 4.6 x 7.5mm 3 96089<br />

XL C8, 5µm 4.6 x 7.5mm 3 96090<br />

XL C1, 5µm 4.6 x 7.5mm 3 96093<br />

XL Silica, 5µm 4.6 x 7.5mm 3 96097<br />

XL SAX, 5µm 4.6 x 7.5mm 3 96098<br />

XL SCX, 5µm 4.6 x 7.5mm 3 96099<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

Allsphere All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

ODS-1, 5µm 4.6 x 7.5mm 3 96402<br />

ODS-2, 5µm 4.6 x 7.5mm 3 96403<br />

C8, 5µm 4.6 x 7.5mm 3 96404<br />

C6, 5µm 4.6 x 7.5mm 3 96405<br />

Phenyl, 5µm 4.6 x 7.5mm 3 96406<br />

Cyano, 5µm 4.6 x 7.5mm 3 96408<br />

Amino, 5µm 4.6 x 7.5mm 3 96409<br />

Silica, 5µm 4.6 x 7.5mm 3 96401<br />

SAX, 5µm 4.6 x 7.5mm 3 96410<br />

SCX, 5µm 4.6 x 7.5mm 3 96411<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

more info<br />

Looking for Adsorbosil ® columns?<br />

Please visit www.discoverysciences.com.<br />

www.discoverysciences.com 59


analytical hplc<br />

hplc columns | small molecule<br />

Grom Sil Columns<br />

High-Quality, Wide Variety, HPLC Columns for All Types of Applications<br />

• Highly consistent manufacturing for excellent reproducibility<br />

• 40 different phases to choose from, general purpose to specialty phases<br />

• Wide range of particle sizes from sub 2μm to 10µm<br />

• Available in nano to preparative column formats<br />

High purity spherical silica with high and universal selectivity for broad range of applications. Different phases and bonding<br />

technologies give you the power and flexibility<br />

ST = standard bonding with endcapping—high-quality universal column<br />

NE = not endcapped—high polar selectivity<br />

HE = hydrophilic endcapping—increased polar selectivity; pH-stable at high pH, high carbon load and very low silanol activity<br />

CP = possiblility to work at high pH<br />

FE = Fully endcapped—maximum silica coverage<br />

PA = Cross-linked polyamino—better stability<br />

pH = pH stable—use mobile phases up to pH 11<br />

Grom Sil Phase Specifications<br />

Base Particle<br />

Material Shape Particle Size Pore Size Surface Area Carbon Load Phase Type<br />

Endcapped?<br />

Phase<br />

ODS-3 CP (encapsulated) Silica Spherical 3, 5, 7, 10µm 120, 300Å 320, 170m 2 /g 15, 6% Polymeric No L1<br />

ODS-4 HE (hydrophilic endcapping) Silica Spherical 3, 4, 5, 7, 10µm 120, 200Å 300, 200m 2 /g 16, 11% Monomeric Yes L1<br />

ODS-5 ST (standard) Silica Spherical 3, 4, 5, 7, 10µm 60, 120, 200Å 580, 300, 200m 2 /g 22, 17, 12% Monomeric Yes L1<br />

ODS-7 pH (pH-stable) Silica Irregular 4µm 80Å 510m 2 /g 22% Polymeric No L1<br />

Octyl-5 CP (encapsulated) Silica Spherical 3, 5, 7, 10µm 120, 300Å 320, 170m 2 /g 10, 5.5% Polymeric No L7<br />

Phenyl-1 FE (fully endcapped) Silica Spherical 3, 5, 10µm 120, 300Å 300, 150m 2 /g 9, 5% Monomeric Yes L11<br />

Phenyl-2 CP (encapsulated) Silica Irregular 5µm 120, 300Å 320, 170m 2 /g 7, 4% Polymeric No L11<br />

Cyano-3 CP (encapsulated) Silica Spherical 5µm 120Å 320m 2 /g 4% Polymeric No —<br />

Amino-2 PA (Crs linked Poly-NH) Silica Spherical 5µm 120Å 300m 2 /g — Polymeric No L8<br />

Diol Silica Spherical 5, 10µm 60, 120, 200Å 580, 300, 200m 2 /g — Monomeric No L20<br />

USP<br />

L-code<br />

0<br />

Color Additives—Dyes<br />

1 2 8<br />

3<br />

4<br />

5<br />

6 7<br />

9 10<br />

11<br />

10 20 30 40 Min.<br />

1. Tartrazine<br />

2. Amaranth<br />

3. Indigo Carmine<br />

4. New Coccine<br />

5. Sunset Yellow<br />

6. Fast Green<br />

7. Brilliant Blue<br />

8. Erythosine<br />

9. Acid Red<br />

10. Phloxine<br />

11. Rosé Bengale<br />

Column: Grom Sil 120 ODS-5 ST, 5µm, 4 x 150mm<br />

Flow Rate: 0.8mL/min<br />

Mobile Phase: A: 10mM NH4-phosphate, pH 6.0:MeOH (90:10)<br />

B: 10mM NH4-phosphate, pH 6.0:MeOH (20:30)<br />

Gradient: 0–100% B (0–40min, linear), 100% B (40–60min)<br />

Column Temp: 30°C<br />

Detector: UV at 254nm<br />

0<br />

1<br />

4 5+6<br />

2 3 7+8<br />

9<br />

1011 12 13 14<br />

17<br />

15 18<br />

16<br />

5 10 15 20 25 30 35 Min.<br />

Nucleosides and Bases<br />

1. Cytosine<br />

2. Cytidine<br />

3. Uracil<br />

4. Deoxycytidine<br />

5. Guanine<br />

6. Adenine<br />

7. Hypoxanthine<br />

8. Uridine<br />

9. Xanthine<br />

10. Thymine<br />

11. Inosine<br />

12. Guanosine<br />

13. Deoxyinosine<br />

14. Deoxyguanosine<br />

15. Xanthosine<br />

16. Thymidine<br />

17. Adenosine<br />

18. Deoxyadenosine<br />

Column: Grom Sil 120 ODS-5 ST, 5μm, 4 x 250mm<br />

Flow Rate: 0.5mL/min<br />

Mobile Phase: A: 20mM NH4-acetate, pH 3.5<br />

B: 20mM NH4-acetate, pH 3.5:MeOH (90:10)<br />

Gradient: Time: 0 5 13 40<br />

%B: 30 30 100 100<br />

Detector: UV at 260nm, 0.08 AUFS<br />

60<br />

www.discoverysciences.com


analytical hplc<br />

Grom Sil Columns<br />

0<br />

1<br />

2<br />

Water-soluble Vitamins<br />

3<br />

4<br />

5<br />

6<br />

Column: Grom Sil 120 ODS-5 ST, 5µm, 4 x 150mm<br />

(Part No. 5113642)<br />

Flow Rate: 0.8mL/min<br />

Mobile Phase: A: 20mM K-phosphate, pH 6.6<br />

B: 20mM K-phosphate, pH 6.6:ACN (80:20)<br />

Gradient: Time: 0 5 20 25<br />

%B: 0 0 100 100<br />

Column Temp: 30°C<br />

Detector: UV at 254nm<br />

0<br />

1<br />

5 10 15 20 25 Min.<br />

2 3 4<br />

6 7<br />

5<br />

8<br />

Fat-soluble Vitamins<br />

9<br />

1. Menadione (Vit. K3)<br />

2. Retinol (Vit. A)<br />

3. Retinol Acetate<br />

4. Menaquinone (Vit. K2)<br />

5. d-Tocopherol<br />

6. Ergocalciferol (Vit. D2)<br />

7. Cholecalciferol (Vit. D3),<br />

8. a-Tocopherol (Vit. E),<br />

9. a-Tocopherol Acetate,<br />

10. Phylloquinone (Vit. K1)<br />

Column: Grom Sil 120 ODS-5 ST, 5µm, 4 x 150mm<br />

(Part No. 5113642)<br />

Flow Rate: 0.8mL/min<br />

Mobile Phase: Acetonitrile<br />

Column Temp: 30°C<br />

Detector: UV at 280nm<br />

10<br />

5 10 15 20 25 Min.<br />

7<br />

8<br />

1. L-Ascorbic Acid (Vit. C)<br />

2. Nicotinic Acid<br />

3. Pyridoxine HCl (Vit. B6)<br />

4. Nicotinamide<br />

5. Thiamine Hydrochloride<br />

(Vit. B1)<br />

6. Folic Acid<br />

7. Cyanocobalamin<br />

(Vit. B12)<br />

8. Riboflavin<br />

Grom Sil Columns<br />

Packing Format i.d. x Length Part No.<br />

ODS-3 CP, 3µm Microbore 1 x 60mm 5115722<br />

Microbore 2 x 125mm 5115672<br />

Microbore 2 x 250mm 5117056<br />

Solvent Reducer 3 x 60mm 5113597<br />

Solvent Reducer 3 x 100mm 5117398<br />

Solvent Reducer 3 x 150mm 5113602<br />

Analytical 4 x 60mm 5113598<br />

Analytical 4.6 x 150mm 5117003<br />

ODS-3 CP, 5µm Solvent Reducer 3 x 125mm 5113604<br />

Analytical 4 x 125mm 5115479<br />

Analytical 4.6 x 250mm 5113609<br />

ODS-4 HE, 10µm Analytical 4.6 x 250mm 5116144<br />

ODS-4 HE, 3µm Capillary 0.3 x 150mm 5118148<br />

Microbore 1 x 50mm 5116060<br />

Microbore 1 x 150mm 5113619<br />

Microbore 2 x 100mm 5115975<br />

Microbore 2 x 125mm 5116880<br />

Microbore 2 x 150mm 5114808<br />

Analytical 4 x 50mm 5118892<br />

Analytical 4 x 60mm 5117386<br />

Analytical 4 x 125mm 5113618<br />

Analytical 4.6 x 125mm 5117572<br />

ODS-4 HE, 5µm Capillary 0.1 x 150mm 5117667<br />

Capillary 0.2 x 250mm 5119092<br />

Capillary 0.5 x 250mm 5118525<br />

Microbore 2 x 125mm 5113623<br />

Microbore 2 x 150mm 5116012<br />

Solvent Reducer 3 x 150mm 5117727<br />

Analytical 4 x 125mm 5115808<br />

Analytical 4 x 250mm 5113626<br />

Analytical 4.6 x 150mm 5116777<br />

ODS-5 ST, 3µm Microbore 2 x 60 mm 5117044<br />

Microbore 2 x 150mm 5118335<br />

ODS-5 ST, 5µm Microbore 2 x 250mm 5116342<br />

Analytical 4 x 125mm 5116219<br />

Analytical 4 x 150mm 5113642<br />

Analytical 4 x 250mm 5113646<br />

Analytical 4.6 x 250mm 5113647<br />

ODS-7 pH, 4µm Capillary 0.3 x 250mm + 5119756<br />

10mm Guard Column<br />

Microbore 1 x 50mm 5118213<br />

Microbore 2 x 40mm 5115266<br />

Solvent Reducer 3 x 150mm 5116956<br />

Analytical 4.6 x 125mm 5113654<br />

Analytical 4.6 x 150mm 5115840<br />

Octyl-5 HE, 3µm Analytical 4.6 x 125mm 5113265<br />

Octyl-5 CP, 5µm Microbore 2 x 250mm 5117325<br />

Analytical 4 x 150mm 5117565<br />

Phenyl-1 FE, 5µm Microbore 2 x 100mm 5113695<br />

Analytical 4 x 250mm 5113696<br />

Phenyl-2 CP, 5µm Analytical 4 x 250mm 5116429<br />

Cyano-3 CP, 5µm Microbore 2 x 125mm 5117410<br />

Analytical 4.6 x 60mm 5116441<br />

Amino-2 PA, 5µm Microbore 2 x 250mm 5115469<br />

Analytical 4 x 250mm 5113466<br />

Analytical 4.6 x 250mm 5115306<br />

Diol, 5µm Microbore 2 x 100mm 5117476<br />

hplc columns | small molecule<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

more info<br />

For large molecule columns, refer to page 84–97.<br />

www.discoverysciences.com 61


analytical hplc<br />

hplc columns | small molecule<br />

Grom Sapphire Column<br />

High Purity for Optimal Performance of Challenging Separations<br />

• Excellent peak shape—Highly symmetrical peaks from high purity silica base<br />

• High speed and high capacity—Range of pore sizes and surface area for improved speed and resolution<br />

• Optimized for consistent flow—critical in low volume applications<br />

• Variety of column formats—1.5, 3, and 5µm particles<br />

Sapphire Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 Silica Spherical 3, 5, 10µm 65, 110Å 500, 270m 2 /g 23, 16% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5, 10µm 65, 110Å 500, 270m 2 /g 15, 10% Monomeric Yes L7<br />

C4* Silica Spherical 3, 5, 10µm 65, 110Å 500, 270m 2 /g 10.5, 7% Monomeric Yes L26<br />

Silica* Silica Spherical 3, 5, 10µm 65, 110Å 500, 270m 2 /g — — No L3<br />

*Columns available upon request.<br />

1<br />

4<br />

2<br />

3<br />

5<br />

Separation of Antiepileptics<br />

6<br />

7 8<br />

1. Ethosuximide<br />

2. Primidone<br />

3. Lamotrigine<br />

4. Phenobarbital<br />

5. Carbamazepine-10,11-epoxide<br />

6. IS, Hexobarbital<br />

7. Phenytoin<br />

8. Carbamazepine<br />

Stability of Grom Sapphire Packings (Daldrup)<br />

1000 mV<br />

500<br />

2<br />

1 3<br />

4<br />

5<br />

1. Uracil<br />

2. 4-Hydroxybenzoic Acid<br />

3. Diphenylhydramine<br />

4. 5-(p-Methylphenyl)-5-phenylhydantoin<br />

5. Diazepam<br />

6. Toluene<br />

6<br />

1000 Injection<br />

500 Injection<br />

0 1 2 3 4 Min.<br />

Column: Grom Sapphire 110 C18, 5µm, 4 x 53mm<br />

(Part No. 5117499)<br />

Flow Rate: 1.5mL/min<br />

Mobile Phase: 50mM Na-phosphate, pH 6.5:MeOH:ACN (62:23:15)<br />

Detector: UV at 204nm<br />

Sapphire HPLC Columns<br />

Packing i.d. x Length Part No.<br />

C18, 3µm 0.030 x 150mm 5119303<br />

0.075 x 150mm 5133239<br />

0.100 x 100mm 5135280<br />

C18, 5µm 4 x 53mm 5117499<br />

4 x 125mm 5117505<br />

C8, 5µm 2 x 250mm 5118934<br />

0<br />

1 Injection<br />

4 8 12 16 20 24 28 32 36 Min.<br />

Column: Grom Sapphire 110 C18, 5µm, 4 x 125mm<br />

(Part No. 5117505)<br />

Flow Rate: 1mL/min<br />

Mobile Phase: 50mM Na-phosphate, pH 2.3:ACN (58:42)<br />

Column Temp: RT<br />

Detector: UV at 230nm<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

related products<br />

Looking for HPLC column<br />

prefilters? See page 111.<br />

related products<br />

Need high-pressure<br />

polymeric fittings?<br />

See pages 112–114<br />

for our full selection of<br />

high-pressure fittings.<br />

6673<br />

62<br />

www.discoverysciences.com


analytical hplc<br />

Grom Amino Acid Column Kits<br />

Amino Acid Analysis by Precolumn<br />

Derivatization Using OPA/IBLC<br />

• High resolution (both optical antipodes of all protein<br />

amino acids in a single chromatogram)<br />

• Outstandingly high sensitivity (fMol)<br />

• Extraordinarily long lifetimes of columns<br />

1. L-Asp<br />

2. D-Asp<br />

3. L-Glu<br />

4. D-GLu<br />

5. L-Ser<br />

6. D-Ser<br />

7. L-Thr<br />

OPA/IBLC Derivatized D- and L-Amino Acids<br />

12 34<br />

14<br />

2930<br />

12 15<br />

5 6 22<br />

7<br />

25<br />

8<br />

19 21<br />

13<br />

18 20<br />

910 26<br />

23 28<br />

24 27<br />

11 16 17<br />

0 10 20 30 40 50 60 70 Min.<br />

8. Gly<br />

9. D-Thr<br />

10. L-His<br />

11. D-His<br />

12. L-Ala<br />

13. L-Arg<br />

14. D-Arg<br />

15. D-Ala<br />

16. L-Tyr<br />

17. D-Tyr<br />

18. L-Val<br />

19. L-Met<br />

20. L-Nor-Val<br />

(Int. Standard)<br />

21. D-Met<br />

22. D-Val<br />

23. L-Phe<br />

24. L-Ile<br />

25. D-Phe<br />

26. L-Leu<br />

Column: Grom Sil OPA-2, 4 x 250mm<br />

Flow Rate: 0.8mL/min<br />

Mobile Phase: A: 23mM Na-acetate, pH 6.0<br />

B: 600mL MeOH + 50mL ACN<br />

Gradient: 0–53% B (0–75min)<br />

Column Temp: 24°C<br />

Detector: Fluorescence 230nm(exc.), 445nm(em.)<br />

27. D-Ile<br />

28. D-Leu<br />

29. L-Lys<br />

30. D-Lys<br />

Amino Acid Analysis by Precolumn<br />

Derivatization With OPA/3-MPA<br />

• Highest sensitivity (5–10fMol)<br />

• Short analysis time<br />

• Fully automated derivatization<br />

• Best resolution<br />

Amino Acid Analysis after Precolumn Derivatization<br />

with OPA/Mercaptopropionic Acid — Extended Standard<br />

1. Asp<br />

2. Glu<br />

3. Asn<br />

4. Ser<br />

1<br />

2<br />

16 17<br />

9 15<br />

13<br />

20 21 22<br />

4 6<br />

11<br />

7 12 18<br />

14<br />

3 8 10<br />

19<br />

5<br />

24<br />

23<br />

0 10 20 30 40 Min.<br />

5. Gin<br />

6. Gly<br />

7. Thr<br />

8. His<br />

9. Cit<br />

10. m-His<br />

11. Ala<br />

12. Tau<br />

13. Arg<br />

14. AAB<br />

15. Tyr<br />

16. Val<br />

17. Met<br />

18. Nor-Val<br />

19. Trp<br />

20. Ile<br />

21. Phe<br />

22. Leu<br />

23. Orn<br />

24. Lys<br />

Column: Grom Sil OPA-1, 4 x 250mm<br />

Mobile Phase: A: 25mM Na-phosphate, pH 7.2:THF (995:5)<br />

B: 25mM Na-phosphate, pH 7.2:MeOH/ACN (50:35:15)<br />

Gradient: Time: 0 3 20 25 36 40 43<br />

%B: 0 0 35 50 60 70 100<br />

Flow Rate: 0.8mL/min<br />

Column Temp: 25°C<br />

Detector: Fluorescence 330nm(exc.), 450nm(em.)<br />

hplc columns | small molecule<br />

OPA/IBLC Kit<br />

Description<br />

Complete kit includes 4.0mm i.d. x 250mm length column,<br />

OPA/IBLC derivitization reagents, and detailed working<br />

instructions.<br />

Part No.<br />

987.0000<br />

OPA/3-MPA Kit<br />

Description<br />

Complete kit includes 4.6mm i.d. x 150mm length column,<br />

OPA/3-MPA derivitization reagents, and detailed working<br />

instructions.<br />

Part No.<br />

980.0000<br />

Amino Acid Analysis by Precolumn<br />

Derivatization Using FLEC/ADAM<br />

• High resolution and high sensitivity<br />

• Rapid, automated or manual derivatization<br />

• Primary and secondary amines<br />

• Stable derivatives<br />

FLEC/ADAM Kit<br />

Description<br />

Complete kit includes 4.0mm i.d. x 250mm length column,<br />

FLEC/ADAM derivitization reagents, and detailed working<br />

instructions.<br />

Part No.<br />

984.0000<br />

Separation of a D-, L-Amino Acid Standard by HPLC<br />

Employing the FLEC-ADAM Approach<br />

1. L-Arg<br />

2. D-Arg<br />

3. L-Ser<br />

4. D-Ser<br />

5. D-Asp<br />

6. L-Asp<br />

7. D-Thr<br />

8. L-Thr<br />

9. D-Glu<br />

10. L-Glu<br />

11. D,L-Pro<br />

12. D-Ala<br />

13. L-Ala<br />

14. FLEC-OH<br />

15. D-Tyr<br />

16. D-Met<br />

17. L-Tyr<br />

18. L-Met<br />

19. D-Val<br />

20. D-Phe<br />

11<br />

14<br />

26<br />

12 20 22 29<br />

13<br />

2 34 7<br />

18<br />

8 9 16 19 21<br />

25<br />

1 10<br />

5<br />

6<br />

1517<br />

23<br />

24 27 28<br />

31 3233<br />

30<br />

20 30 40 50 60 70 Min.<br />

21. L-Val<br />

22. L-Phe<br />

23. D-allo-lie<br />

24. D-lle<br />

25. D-Leu<br />

26. L-allo-lie;<br />

L-lie<br />

27. L-Leu<br />

Column:<br />

Flow Rate:<br />

Mobile Phase:<br />

Gradient: Time: 0 8 22 70<br />

%B: 17 17 30 50<br />

%C: 8 8 0 0<br />

28. D-His<br />

29. D-Om<br />

30. L-His<br />

31. D-Lys<br />

Grom Sil FLEC-1, 4 x 250mm<br />

0.75mL/min<br />

A: 50mM Na-acetate, pH 4.0 B: ACN C: THF<br />

Column Temp: 40°C<br />

Detector: Fluorescence 263nm(exc.), 313nm(em.)<br />

32. L-Om<br />

33. L-Lys<br />

www.discoverysciences.com 63


analytical hplc<br />

hplc columns | small molecule<br />

Jones Genesis ® Columns<br />

Genesis ® columns use a new generation adsorbent based<br />

on high-purity metal-free 120Å spherical silica. Particle size<br />

offering includes 3, 4, 7, and 15µm. Genesis ® columns exhibit<br />

excellent peak symmetry and exceptional pH stability from<br />

1 to 10.<br />

Genesis ® Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 Silica Spherical 3, 4, 7, 15µm 120Å 300m 2 /g 18% Monomeric Yes L1<br />

AQ Silica Spherical 4, 7µm 120Å 300m 2 /g 15% Monomeric Yes L1<br />

C8 Silica Spherical 3, 4, 7, 15µm 120Å 300m 2 /g 11% Monomeric No L7<br />

C8e/c Silica Spherical 3, 4, 7, 15µm 120Å 300m 2 /g 11% Monomeric Yes L7<br />

C4 Silica Spherical 4µm 120Å 300m 2 /g 6.3% Monomeric Yes L26<br />

Phe Silica Spherical 4µm 120Å 300m 2 /g 9.4% Monomeric Yes L11<br />

CN Silica Spherical 3, 4µm 120Å 300m 2 /g 7% Monomeric Yes L10<br />

Amino (NH2) Silica Spherical 3, 4µm 120Å 300m 2 /g 3.5% Polymeric No L8<br />

Carbohydrate Silica Spherical 4µm 120Å 300m 2 /g — Monomeric — —<br />

CN-TCA Silica Spherical 4µm 120Å 300m 2 /g 7% Monomeric Yes —<br />

Petro-XP Silica Spherical 4µm 120Å 300m 2 /g — Monomeric — —<br />

Silica Silica Spherical 3, 4, 7, 15µm 120Å 300m 2 /g n/a n/a n/a L3<br />

Genesis ® C18 Reversed Phase<br />

• Excellent peak symmetry<br />

• Exceptional stability from pH 1 to 10<br />

• Reduced need for mobile-phase modifiers<br />

• Long column life<br />

Genesis ® C18 bonding is monomeric. A unique proprietary<br />

end-capping reagent, which is less prone to acid hydrolysis<br />

than trimethylsilane, provides freedom from residual silanols<br />

and enhanced stability under low-pH operating conditions.<br />

Genesis ® C18 columns also exhibit superior stability at<br />

alkaline pH. The permissible operating range is pH 1–10.<br />

Genesis ® AQ Reversed Phase<br />

• Designed for separating hydrophilic and polar<br />

compounds<br />

• Stable retention times in 100% aqueous mobile phases<br />

• Rapid equilibration<br />

• Unique reversed-phase selectivity<br />

The Genesis ® AQ adsorbent employs an optimum ratio of<br />

C18, short (non-TMS) chains, and polar surface groups<br />

bonded to high-purity 120Å silica to allow rapid equilibration<br />

and provide consistent, reproducible chromatography with<br />

stable retention times in 100% aqueous eluents.<br />

1<br />

2<br />

0 1 2 3 4 5 Min.<br />

Column:<br />

Flow Rate:<br />

Mobile Phase:<br />

Detector:<br />

Inertness Test<br />

3<br />

4<br />

1. Uracil<br />

2. Pyridine<br />

3. 2,3-Dimethylphenol<br />

4. Methylbenzoate<br />

Genesis ® FM15960E C18, 4µm, 4.6 x 150mm<br />

0.8mL/min<br />

Isocratic, 50% ACN in water<br />

UV at 254nm<br />

Retention on Genesis ® AQ is greater for polar analytes but<br />

lower for non-polar compounds compared to Genesis ® C18.<br />

Uracil, which is typically an unretained peak on C18 columns,<br />

is well retained on the Genesis ® AQ adsorbent. Acids and<br />

bases exhibit good peak shapes. Although Genesis ® AQ<br />

excels with water-rich mobile phases, it can also be used in<br />

gradient and isocratic modes with a full spectrum of mobile<br />

phases.<br />

1<br />

2<br />

3 4<br />

Nucleotide 5'-Monophosphates<br />

0 2 4 6 8 10 12 14 Min.<br />

5<br />

1. KNO3<br />

2. CMP<br />

3. UMP<br />

4. GMP<br />

5. AMP<br />

Column: Genesis ® FM15951E AQ, 4µm, 4.6 x 150mm<br />

Flow Rate: 1.0mL/min<br />

Mobile Phase: Isocratic, 50mM NH4OAc, pH 5.5<br />

Detector: UV at 254nm<br />

Column Temp: 30°C<br />

64<br />

www.discoverysciences.com


analytical hplc<br />

Jones Genesis ® Columns<br />

Genesis ® C8(EC) Reversed Phase<br />

• Excellent peak symmetry<br />

• Exceptional stability from pH 1 to 10<br />

• Reduced need for mobile-phase modifiers<br />

• Long column life<br />

C8(EC) is double-bonded before fully endcapped using a<br />

unique proprietary end-capping reagent. It is less prone to<br />

acid hydrolysis than trimethylsilane, which provides freedom<br />

from residual silanols and enhanced stability under low-pH<br />

operating conditions. The bonding is monomeric. Genesis ®<br />

C8(EC) columns exhibit superior stability at alkaline pH.<br />

Genesis ® C8 Reversed Phase<br />

• Non-endcapped<br />

• Suitable for lower pH separations<br />

Genesis ® C8 bonding is monomeric. They are suitable<br />

for separations under lower pH conditions and may offer<br />

selectivity advantages for some samples.<br />

Genesis ® Phenyl<br />

• Unique reversed-phase chemistry<br />

• Improve the chromatography of polar aromatic, fatty<br />

acids, and basic pharmaceuticals<br />

Genesis ® Phenyl columns provide impressive peak symmetry<br />

for both acidic and basic compounds.<br />

Genesis ® Columns Genesis ® Guards 1<br />

Length: 30mm 50mm 100mm 150mm 200mm 250mm 10mm 20mm<br />

Genesis ® AQ<br />

4µm 1.0mm i.d. — FJ5951E FJ10951E FJ15951E — FJ25951E FJ1951-2 —<br />

2.1mm i.d. FK3951E FK5951E FK10951E FK15951E FK20951E FK25951E FK1951-2 FK2951-2<br />

3.0mm i.d. FL3951E FL5951E FL10951E FL15951E — FL25951E FL1951-2 FL2951-2<br />

4.0mm i.d. FH3951E FH5951E FH10951E FH15951E — FH25951E FH1951-2 FH2951-2<br />

4.6mm i.d. FM3951E FM5951E FM10951E FM15951E FM20951E FM25951E — —<br />

Genesis ® C18<br />

3µm 1.0mm i.d. — FJ5963E FJ10963E FJ15963E — FJ25963E FJ1963-2 —<br />

2.1mm i.d. FK3963E FK5963E FK10963E FK15963E FK20963E FK25963E FK1963-2 FK2963-2<br />

3.0mm i.d. FL3963E FL5963E FL10963E FL15963E — FL25963E — —<br />

4.0mm i.d. FH3963E FH5963E FH10963E FH15963E — FH25963E FH1963-2 FH2963-2<br />

4.6mm i.d. FM3963E FM5963E FM10963E FM15963E FM20963E FM25963E — —<br />

4µm 1.0mm i.d. — FJ5960E FJ10960E FJ15960E — FJ25960E FJ1960-2 —<br />

2.1mm i.d. FK3960E FK5960E FK10960E FK15960E FK20960E FK25960E FK1960-2 FK2960-2<br />

3.0mm i.d. FL3960E FL5960E FL10960E FL15960E — FL25960E FL1960-2 FL2960-2<br />

4.0mm i.d. FH3960E FH5960E FH10960E FH15960E — FH25960E FH1960-2 FH2960-2<br />

4.6mm i.d. FM3960E FM5960E FM10960E FM15960E FM20960E FM25960E — —<br />

Genesis ® C8<br />

3µm 1.0mm i.d. — FJ5968E FJ10968E FJ15968E — FJ25968E FJ1968-2 —<br />

2.1mm i.d. FK3968E FK5968E FK10968E FK15968E FL20968E FK25968E FK1968-2 FK2968-2<br />

3.0mm i.d. FL3968E FL5968E FL10968E FL15968E — FL25968E FL1968-2 FL2968-2<br />

4.0mm i.d. FH3968E FH5968E FH10968E FH15968E — FH25968E FH1968-2 FH2968-2<br />

4µm 1.0mm i.d. — FJ5962E FJ10962E FJ15962E — FJ25962E FJ1962-2 —<br />

2.1mm i.d. FK3962E FK5962E FK10962E FK15962E FK20962E FK25962E FK1962-2 FK2962-2<br />

3.0mm i.d. FL3962E FL5962E FL10962E FL15962E — FL25962E FL1962-2 FL2962-2<br />

4.0mm i.d. FH3962E FH5962E FH10962E FH15962E — FH25962E FH1962-2 FH2962-2<br />

4.6mm i.d. FM3962E FM5962E FM10962E FM15962E FM20962E FM25962E — —<br />

Genesis ® C8(EC)<br />

3µm 1.0mm i.d. — FJ5969E FJ10969E FJ15969E — FJ25969E FJ1969-2 —<br />

2.1mm i.d. FK3969E FK5969E FK10969E FK15969E FK20969E FK25969E FK1969-2 FK2969-2<br />

3.0mm i.d. FL3969E FL5969E FL10969E FL15969E — FL25969E FL1969-2 FL2969-2<br />

4.0mm i.d. FH3969E FH5969E FH10969E FH15969E — FH25969E FH1969-2 FH2969-2<br />

4.6mm i.d. FM3969E FM5969E FM10969E FM15969E FM20969E FM25969E — —<br />

4µm 1.0mm i.d. — FJ5964E FJ10964E FJ15964E — FJ25964E FJ1964-2 —<br />

2.1mm i.d. FK3964E FK5964E FK10964E FK15964E FK20964E FK25964E FK1964-2 FK2964-2<br />

3.0mm i.d. FL3964E FL5964E FL10964E FL15964E — FL25964E FL1964-2 FL2964-2<br />

4.0mm i.d. FH3964E FH5964E FH10964E FH15964E — FH25964E FH1964-2 FH2964-2<br />

4.6mm i.d. FM3964E FM5964E FM10964E FM15964E FM20964E FM25964E — —<br />

Genesis ® Phenyl<br />

4µm 1.0mm i.d. — FJ5980E FJ10980E FJ15980E — FJ25980E FJ1980-2 —<br />

2.1mm i.d. FK3980E FK5980E FK10980E FK15980E FK20980E FK25980E FK1980-2 FK2980-2<br />

4.0mm i.d. FH3980E FH5980E FH10980E FH15980E — FH25980E FH1980-2 FH2980-2<br />

4.6mm i.d. FM3980E FM5980E FM10980E FM15980E FM20980E FM25980E FH1980-2 FH2980-2<br />

NOTE: Genesis ® line is completed by additional phases such as Silica, Phenyl, Cyano, and Amino, for details please check online at www.discoverysciences.com.<br />

1<br />

All Genesis ® guards listed are cartridges and require either a stand-alone holder or direct-connect holder for use. Guard cartridges are 2/pk.<br />

hplc columns | small molecule<br />

Guard Cartridge Holders for Genesis ® and Apex Guards<br />

10 mm Stand-Alone 20 mm Stand-Alone 10 mm Direct-Connect 20 mm Direct-Connect<br />

1.0 mm i.d. F91GPH — — —<br />

2.1 mm i.d. F9111P F9112P F9141P —<br />

3.0, 4.0, 4.6 mm i.d. F9111P F9112P F9151P F9152P<br />

www.discoverysciences.com 65


analytical hplc<br />

hplc columns | small molecule<br />

Jones Apex Reversed-Phase Columns<br />

Economical Column Line with Maximum Reproducibility and Efficiency<br />

• Conventional 100Å pore size spherical silica<br />

• Uniform-sized particle<br />

• Narrow particle distribution<br />

• Controlled surface area<br />

Apex Phase Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

ODS Silica Spherical 3, 5, 10µm 100Å 170m 2 /g 10% Polymeric Yes L1<br />

ODS II Silica Spherical 3, 5µm 100Å 170m 2 /g 10.5% Monomeric Yes L1<br />

C8 Silica Spherical 3, 5µm 100Å 170m 2 /g 7% Monomeric No L7<br />

C8(EC) Silica Spherical 3, 5µm 100Å 170m 2 /g 7% Monomeric Yes L7<br />

C1 Silica Spherical 3, 5µm 100Å 170m 2 /g 2.5% Monomeric Yes L13<br />

Diol Silica Spherical 3, 5µm 100Å 170m2/g 3.5% Monomeric No<br />

Phe Silica Spherical 3, 5µm 100Å 170m 2 /g 3% Monomeric Yes L11<br />

CN Silica Spherical 3, 5µm 100Å 170m 2 /g 4% Monomeric No L10<br />

Amino (NH2) Silica Spherical 3, 5µm 100Å 170m 2 /g 2% Monomeric No L8<br />

Amino II (NH2) Silica Spherical 3, 5µm 100Å 170m 2 /g 2% Monomeric No L8<br />

Carbohydrate Silica Spherical 5µm 100Å 170m 2 /g — Monomeric Proprietary —<br />

Silica Silica Spherical 3, 5, 10µm 100Å 170m 2 /g n/a% n/a No L3<br />

Apex HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

ODS, 3µm Analytical 4.6 x 50mm 5110394<br />

ODS, 5µm Analytical 4.6 x 30mm 5109740<br />

Analytical 4.6 x 50mm 5140902<br />

Analytical 4.6 x 150mm 5140900<br />

Analytical 4.6 x 250mm 5140901<br />

ODS II, 3µm Analytical 4.6 x 100mm 5110994<br />

Analytical 4.6 x 250mm 5111025<br />

ODS II, 5µm Analytical 4.6 x 50mm 5109944<br />

Analytical 4.6 x 100mm 5112992<br />

Analytical 4.6 x 150mm 5109730<br />

Analytical 4.6 x 250mm 5109733<br />

C8, 5µm Analytical 4.6 x 30mm 5112351<br />

Analytical 4.6 x 150mm 5109921<br />

Analytical 4.6 x 250mm 5109734<br />

C8(EC), 5µm Analytical 4.6 x 30mm 5112354<br />

Analytical 4.6 x 250mm 5109735<br />

Diol, 5µm Analytical 4.6 x 150mm 5120721<br />

Phenyl, 5µm Analytical 4.6 x 100mm 5110997<br />

Analytical 4.6 x 150mm 5110650<br />

Analytical 4.6 x 250mm 5109934<br />

Cyano, 5µm Analytical 4.6 x 250mm 5109737<br />

Cyano II, 5µm Analytical 4.6 x 250mm 5109933<br />

Amino, 5µm Analytical 4.6 x 150mm 5112313<br />

Analytical 4.6 x 250mm 5111029<br />

Amino II, 3µm Analytical 4.6 x 150mm 5111004<br />

Silica, 3µm Analytical 4.6 x 150mm 5109698<br />

Silica, 5µm Analytical 4.6 x 250mm 5110044<br />

Analytical 4.6 x 250mm 5111024<br />

Apex Guard Columns<br />

Packings i.d. x Length Part No.<br />

ODS, 5µm 4 x 10mm 5110703<br />

ODS II, 5µm 4 x 20mm 5110705<br />

C8, 5µm 4 x 20mm 5112454<br />

C8-EC, 5µm 4 x 10mm 5112425<br />

Cyano, 5µm 4 x 10mm 5111079<br />

Amino, 5µm 4 x 10mm 5111078<br />

4 x 20mm 5112455<br />

Guard Cartridge Holder 10mm F9111P<br />

20mm<br />

F9112P<br />

Column:<br />

Flow Rate:<br />

Mobile Phase:<br />

2 4<br />

1 3<br />

Apex ODS II, C18, 5µm, 4.6 x 250mm<br />

0.8mL/min<br />

A: 10 mM NaOAc, 0.02% THF<br />

B: 10 mM NaOAc, 2.7% THF, 25% ACN<br />

Gradient: Time: 0 35<br />

%B: 0 70<br />

Column Temp: 50°C<br />

Detector: UV at 273nm<br />

5<br />

6<br />

7<br />

Xanthines in Plasma<br />

11<br />

9<br />

8<br />

10<br />

0 4 8 12 16 20 24 28 Min.<br />

12<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

1. 7-Methylxanthine<br />

2. 3-Methylxanthine<br />

3. 1-Methylxanthine<br />

4. 1,3-Methyluric Acid<br />

5. Theobromine<br />

6. Ethylxanthine<br />

7. Methyluric Acid<br />

8. Paraxanthine<br />

9. Theophylline<br />

10. 1,3,7-Methyluric Acid<br />

11. Ethyltheophylline<br />

12. Caffeine<br />

66<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® OPA Amino Acid<br />

Columns<br />

• OPA-HS for high-speed with protein hydrolysates<br />

• OPA-HR for high-resolution with physiological samples<br />

OPA-HS (high-speed) columns are ideal for the study of<br />

protein acid hydrolysates with very simple mobile-phase<br />

systems.<br />

OPA-HR (high-resolution) columns are ideal for applications<br />

that require more resolution than simple hydrolysates.<br />

OPA-HR gives baseline separation of most amino acids<br />

found in physiological fluids.<br />

0<br />

1<br />

2<br />

OPA-Derivatized Amino Acids<br />

3<br />

4<br />

5 6<br />

7<br />

8<br />

9<br />

OPA Amino Acid HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

OPA-HS, 5µm Analytical 4.6 x 100mm 28064<br />

OPA-HR, 5µm Analytical 4.6 x 150mm 28072<br />

Derivatization Reagents<br />

Description Qty. Part No.<br />

OPA Crystals 5g 35606<br />

10<br />

13<br />

11<br />

5 10 15 20 25 30 Min.<br />

12<br />

14<br />

15<br />

9234<br />

1. Aspartic Acid<br />

2. Glutamic Acid<br />

3. Serine<br />

4. Histidine<br />

5. Glycine<br />

6. Threonine<br />

7. Arginine<br />

8. Alanine<br />

9. Tyrosine<br />

10. Methionine<br />

11. Valine<br />

12. Phenylalanine<br />

13. Isoleucine<br />

14. Leucine<br />

15. Lysine<br />

Column: OPA-HR, 5µm, 4.6 x 150mm (Part No. 28072)<br />

Mobile Phase: A: Methanol B: Tetrahydrofuran<br />

C: 20mM Sodium Acetate buffer, pH 5.5<br />

Gradient: Time: 0 20<br />

%A: 5 65<br />

%B: 5 2<br />

%C: 90 23<br />

Flow Rate: 1.5mL/min<br />

Detector: Fluorescence<br />

Alltech ® Catecholamine<br />

Columns<br />

• For routine analysis of indoles and catecholamines<br />

• Reliable and inexpensive<br />

With this column, easily resolve catecholamines under isocratic<br />

conditions at room temperature. A simple monochloroacetic<br />

acid mobile phase with varying amounts of sodium octyl<br />

sulfate and disodium EDTA controls the elution profile.<br />

Catecholamine HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Catecholamine, 3µm Analytical 4.6 x 100mm 28916<br />

All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

Catecholamine, 3µm 4.6 x 7.5mm 3 96076<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required.<br />

Alltech ® Nucleotide-<br />

Nucleoside Columns<br />

• Determine both nucleotides and nucleosides with a<br />

single column<br />

With this column, separate seven common nucleosides or<br />

twelve common nucleotides using a buffer/methanol/tetrabutyl<br />

ammonium phosphate gradient.<br />

Nucleotide-Nucleoside HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Nucleotide-Nucleoside, 7µm Analytical 4.6 x 250mm 35623<br />

All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

Nucleotide-Nucleoside, 7µm 4.6 x 7.5mm 3 96077<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required.<br />

7110<br />

hplc columns | small molecule<br />

more info<br />

For related products, see our Vydac ® line of Life Science columns<br />

on pages 85–95.<br />

www.discoverysciences.com 67


analytical hplc<br />

hplc columns | small molecule<br />

Alltech ® Mixed-Mode<br />

Columns<br />

• Separate hydrophobic and ionic species on a<br />

single column<br />

• Control ionization with buffer adjustments instead of<br />

ion-pair reagents<br />

1<br />

1<br />

Anesthetics and Neutral<br />

2<br />

2<br />

3<br />

3<br />

8780<br />

8781<br />

1. Biphenyl<br />

2. Lidocaine<br />

3. Procaine<br />

Alltech ® Carbohydrate<br />

Cation Columns<br />

• High efficiency separations<br />

using only water as the<br />

mobile phase<br />

• Sulfonated polystyrene<br />

resin in the calcium form<br />

• Column heating required<br />

100% Pure Red Delicious Apple Juice<br />

(a 1:250 Dilution)<br />

4<br />

8965<br />

1. Unknown<br />

2. Sucrose<br />

3. Glucose<br />

4. Fructose<br />

5. Sorbitol<br />

7110<br />

2<br />

3<br />

0 5<br />

10 15 20 Min.<br />

Column: Mixed-Mode C8/Cation, 5µm, 4.6 x 150mm<br />

Mobile Phase: 8780: 55mM K2HPO4, pH6.5: Acetonitrile (50:50)<br />

8781: 45mM K2HPO4, pH6.5: Acetonitrile (50:50)<br />

Flow Rate: 1.0mL/min<br />

Column Temp: 30°C<br />

Detector: UV at 220nm<br />

Changing the buffer concentration affects the capacity of the cationic<br />

components lidocaine and procaine, but does not affect the capacity<br />

of biphenyl, a neutral component.<br />

Mixed-Mode HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

C8/Anion, 7µm Analytical 4.6 x 150mm 71354 71355<br />

Analytical 4.6 x 250mm 12369 12370<br />

C8/Cation, 5µm Analytical 4.6 x 150mm 72568 72569<br />

Analytical 4.6 x 250mm 71364 71365<br />

C18/Cation, 5µm Analytical 4.6 x 150mm 72574 72575<br />

Analytical 4.6 x 250mm 71369 71370<br />

1<br />

0 5<br />

Carbohydrate Cation HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Carbohydrate Cation, 10µm Analytical 6.5 x 300mm 70057<br />

more info<br />

For Alltech ® Prevail Carbohydrate ES columns, see page 47.<br />

5<br />

10 15 Min.<br />

Column: Alltech ® Carbohydrate Cation, 10µm, 6.5 x 300mm<br />

(Part No. 70057)<br />

Mobile Phase: Water<br />

Flow Rate: 0.5mL/min<br />

Column Temp: 90°C<br />

Detector: Alltech ELSD<br />

Carbohydrate Cation All-Guard Cartridges<br />

Packing i.d. x Length Qty. Part No.<br />

Carbohydrate Cation Guard Cartridges 4.6 x 7.5mm 3 96109<br />

All-Guard Cartridge Holder<br />

80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required.<br />

Mixed-Mode All-Guard Cartridges*<br />

Packing, 5µm i.d. x Length Qty. Part No.<br />

C8/Anion 4.6 x 7.5mm 3 96147<br />

C8/Cation 4.6 x 7.5mm 3 71379<br />

C18/Cation 4.6 x 7.5mm 3 71380<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

related product<br />

Need a column heater?<br />

See pages 16 and 17.<br />

related product<br />

Doing carbohydrate analysis?<br />

Alltech ® 3300 ELSD is more<br />

sensitive than RI. See pages 5–10.<br />

6219<br />

6947B<br />

68<br />

www.discoverysciences.com


analytical hplc<br />

Vydac ® Venture ® Immunoaffinity Columns<br />

Repetitive-Use, Silica-Based Immunoaffinity Columns<br />

Venture ® immunoaffinity HPLC columns provide an easy and quick way to purify and concentrate analytes from complex food,<br />

environmental, and biological matrices for fast, accurate measurement.<br />

6908<br />

Vydac ® Venture ® immunoaffinity columns use ICEtech (Inert Coating Enhancement Technology, U.S. Patent No. 6,802,966)<br />

silica processing to eliminate non-specific binding on the silica surface. This enables Venture ® columns to be the first affinity<br />

matrix to take advantage of silica’s rigid porous structure, making direct coupling of the columns with other modes<br />

of chromatography, such as reversed-phase HPLC feasible.<br />

Benefits<br />

Rapid Analysis<br />

Excellent Accuracy and<br />

Precision<br />

Highly Selective<br />

Features<br />

• No laborious sample preparation<br />

procedures<br />

• Fast binding kinetics<br />

• Wide-pore silica support allows online<br />

coupling with HPLC for real time<br />

direct analysis<br />

• Quantitative recovery of analyte from<br />

IAC column<br />

• High sensitivity due to high volume<br />

injection<br />

• Precision comparable with<br />

conventional HPLC methods<br />

• Specially treated wide-pore silica<br />

eliminates non-specific interactions<br />

• Secondary separation reduces errors<br />

due to cross reactivity<br />

• Highly selective antibodies toward<br />

target analyte<br />

Long Column Lifetime<br />

• Analyze over 200 samples on a single<br />

column without column deterioration<br />

due to the high ligand stability of the<br />

Venture ® IAC columns<br />

Analysis of Difficult Matrices • Venture ® IAC columns isolate,<br />

concentrate and purify targeted<br />

sample components from dilute and<br />

complex matrices in one step<br />

Significant Cost Reductions • Costs reduced by as much as 90%<br />

Automated Analysis<br />

• Long column lifetime decreases<br />

material costs to less than $5.00<br />

per analysis<br />

• Rapid analysis and automation<br />

reduces technician time<br />

• Significant reduction in solvent use<br />

• Less solvent waste disposal costs<br />

• HPLC format allows automation for<br />

high sample throughput<br />

Venture ® Immunoaffinity Columns<br />

Product Name Target Analyte i.d. and length Part No.<br />

Mycotoxins Analysis<br />

Venture ® AF Aflatoxin 2.1 x 50mm 5120313<br />

Venture ® OT Ochratoxin A 2.1 x 50mm 5135954<br />

Food Nutrient Analysis<br />

Venture ® FA Folic Acid 2.1 x 50mm 5135952<br />

Venture ® B12 Vitamin B12 2.1 x 50mm 5120201<br />

Venture ® BF Folic Acid and Vitamin B12 2.1 x 50mm 5135951<br />

Acrylamide Analysis<br />

Venture ® AC Acrylamide 2.1 x 50mm 5135953<br />

Lactoferrin Analysis<br />

Venture ® LTF Lactoferrin 2.1 x 50mm 5120400<br />

Endocrine Disruptors Analysis<br />

Venture ® EE2 17α-Ethynyl Estradiol 2.1 x 50mm 5120404<br />

Venture ® E2 17β-Estradiol 2.1 x 50mm 5120403<br />

Venture ® E1 Estrone 2.1 x 50mm 5120405<br />

Venture ® BPA Bisphenol A 2.1 x 50mm 5120406<br />

Pollutants Analysis<br />

Venture ® CPA Chlorophenoxy Acetic Acid 2.1 x 50mm 5120407<br />

Herbicides<br />

Venture ® PVH Phenylurea Herbicides 2.1 x 50mm 5120408<br />

Venture ® OPP Organophosphorous 2.1 x 50mm 5120410<br />

Pesticides<br />

Venture ® VCZ Vinclozolin Fungicide 2.1 x 50mm 5120411<br />

Steroid Hormones Analysis<br />

Venture ® TT Testosterone 2.1 x 50mm 5120401<br />

Venture ® NT Nortestosterone 2.1 x 50mm 5120402<br />

hplc columns | small molecule<br />

Vydac ® Denali ® C18 Reversed Phase<br />

Denali ® columns contain a new-generation silica-based 120Å monomeric C18 adsorbent<br />

based on the same bonding technology employed in Vydac ® Everest ® 300Å columns. This new<br />

technology improves C18 surface coverage and deactivates residual silanols. Previously, the<br />

best monomeric C18 chemistries had carbon coverage in the 2.8 to 3.6µmoL/m 2 range. Denali ®<br />

C18 has coverage in excess of 4µmoL/m 2 and approximates the theoretical limit based on<br />

surface area.<br />

7110<br />

Vydac ® Denali ® C18 Reversed-Phase 238DE C18<br />

Columns<br />

Recommended Guards<br />

Particle Size i.d. 50mm 100mm 150mm 250mm Guard Kit 1 Guard Cartridge 2<br />

3µm 2.1mm 3 238DE3205 238DE3210 — — — —<br />

4.6mm 3 238DE3405 238DE3410 — — 238GK34DE 238GD34DE<br />

5µm 1.0mm 3 238DE5105 238DE5110 238DE5115 238DE51 238GK51DE 238GD51DE<br />

2.1mm 3 238DE5205 238DE5210 238DE5215 238DE52 238GK52DE 238GD52DE<br />

4.6mm 3 238DE5405 238DE5410 238DE5415 238DE54 238GK54DE 238GD54DE<br />

NOTE: Additional column diameters and lengths are available on request. Please contact <strong>Grace</strong> Davison Discovery Sciences to discuss your requirements.<br />

1<br />

A guard kit includes a holder and one guard cartridge. 2 Guard cartirdge units include two guard cartridges. 3 Titanium frits are standard in column diameters 4.6mm and smaller.<br />

www.discoverysciences.com 69


analytical hplc<br />

hplc columns | small molecule<br />

Vydac ® 201TP and 202TP C18<br />

Specialty Reversed Phases for PAH and Vitamins<br />

• 201TP: The standard for PAH analysis in all types of environmental samples. Vydac ® 201TP<br />

columns separate the EPA 16 priority pollutants in less than 20 minutes.<br />

• 202TP3405: Rapid analysis to separate the 16 priority pollutant PAHs in under 10 minutes<br />

• 202TP54 and 202TP5415: For the analysis of derivatized PAHs<br />

Vydac ® 201TP and 202TP columns were developed specifically for the separation and quantification of PAHs required by<br />

environmental regulations, current and future. Beyond the 16 EPA priority pollutant PAHs, Vydac ® PAH columns are used to<br />

separate many other PAHs, such as methylated naphthalenes.<br />

Vydac ® 201TP and 202TP C18 Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

201TP C18 Silica Spheroidal 5, 7, 10, 10–15, 15–20µm 300Å 70–90m 2 /g 8% Polymeric No L1<br />

202TP C18 Silica Spheroidal 3, 5, 10µm 300Å 60–90m 2 /g 9% Polymeric No L1<br />

Vydac ® 201TP<br />

Vydac ® 201TP HPLC columns have long been the standard for the analysis of PAHs in water, air, soil, automotive exhaust,<br />

and food. They were used to establish standard reference materials, measure air quality, measure PAHs in sediments,<br />

quantify PAHs in food, and study high molecular weight PAHs. They have also been used in the study of shape selectivity<br />

of reversed-phase materials.<br />

Priority Pollutants PAHs<br />

In Accordance with<br />

EPA Methods 505, 550.1, 610, and 8310<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. Acenaphthene<br />

4. Fluorene<br />

5. Phenanthrene<br />

6. Anthracene<br />

7. Fluoranthene<br />

8. Pyrene<br />

9. Benz[a]anthracene<br />

10. Chrysene<br />

11. Benzo[b]fluoranthene<br />

12. Benzo[k]fluoranthene<br />

13. Benzo[a]pyrene<br />

14. Dibenz[ah]anthracene<br />

15. Benzo[ghi]perylene<br />

16. Indeno[1,2,3-cd]pyrene<br />

11<br />

PAHs Beyond the EPA Priority Pollutants<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. 1-Methylnaphthalene<br />

4. 2-Methylnaphthalene<br />

5. Acenaphthene<br />

6. Fluorene<br />

7. Phenanthrene<br />

8. Anthracene<br />

9. Fluoranthene<br />

10. Pyrene<br />

11. Benzo[c]phenanthrene<br />

12. Cyclopenta[cd]pyrene<br />

2<br />

8<br />

13. Benz[a]anthracene<br />

14. Chrysene<br />

15. Benzo[b]naptho[2,1-d]thiopen<br />

16. 7,12-Dimethylbenz[a]anthracene<br />

17. Benzo[e]pyrene<br />

18. Benzo[b]fluoranthene<br />

19. Benzo[k]fluoranthene<br />

20. Benzo[a]pyrene<br />

21. Dibenz[ah]anthracene<br />

22. Benzo[ghi]perylene<br />

23. Indeno[1,2,3-cd]pyrene<br />

7110<br />

10<br />

1<br />

7<br />

18<br />

1<br />

2<br />

3<br />

4<br />

5 6 7<br />

8<br />

9<br />

12<br />

13 16<br />

15<br />

14<br />

3 45 6<br />

9<br />

10<br />

1112 13 14<br />

15 16 17<br />

19<br />

20<br />

22<br />

21<br />

23<br />

0 1 3 5 7 9 11 13 15 Min.<br />

0 4 8 12 16 20 24 28 32 Min.<br />

Column:<br />

Flow Rate:<br />

Mobile Phase:<br />

Gradient:<br />

Detector:<br />

Vydac ® C18, 5µm, 4.6 x 150mm<br />

(Part No. 201TP5415)<br />

1.5mL/min<br />

A: Water B: ACN<br />

Hold 50% B for 3min, then 50 to 100% B in 7min<br />

UV at 254nm<br />

Column: Vydac ® C18, 5µm, 4.6 x 150mm<br />

(Part No. 201TP5415)<br />

Flow Rate: 1.0mL/min<br />

Mobile Phase: A: Water B: ACN<br />

Gradient: 50 to 100% B over 30min<br />

Column Temp: 30°C<br />

Detector: UV at 254nm<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

70<br />

www.discoverysciences.com


analytical hplc<br />

Vydac ® 201TP (continued)<br />

Vitamins<br />

Vydac ® 201TP columns also have application in the analysis<br />

of carotenoids, retinoids, and vitamins.<br />

Vydac ® 202TP<br />

Built on top of the success of 201TP, 202TP columns are<br />

ideal for derivatized PAH samples or high throughput PAH<br />

analyses.<br />

Retinol, a-Tocopherol, and b-Carotene in Serum<br />

1. All-trans-retinol (vitamin A)<br />

2. Tocol<br />

3. g-Tocopherol<br />

4. a-Tocopherol (vitamin E)<br />

5. Lutein<br />

6. Zeaxanthin<br />

7. Cryptoxanthin<br />

8. a-Carotene<br />

9. All-trans-b-carotene<br />

10. Cis-b-carotene<br />

325 nm 295 nm 450 nm<br />

7<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

0 4 8 12 16 20 24 28 32 Min.<br />

8<br />

9<br />

10<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. Acenaphthene<br />

4. Fluorene<br />

5. Phenanthrene<br />

6. Anthracene<br />

7. Fluoranthene<br />

8. Pyrene<br />

1<br />

2<br />

Rapid Analysis of Polyaromatic Hydrocarbons<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9. Benz[a]anthracene<br />

10. Chrysene<br />

11. Benzo[b]fluoranthene<br />

12. Benzo[k]fluoranthene<br />

13. Benzo[a]pyrene<br />

14. Benzo[ghi]perylene<br />

15. Dibenz[ah]anthracene<br />

16. Indeno[1,2,3-cd]pyrene<br />

9 10 11<br />

12<br />

13 14<br />

15<br />

16<br />

hplc columns | small molecule<br />

Column:<br />

Flow Rate:<br />

Mobile Phase:<br />

Gradient:<br />

Detector:<br />

Vydac ® 201TP C18, 5µm, 4.6 x 250mm<br />

(Part No. 201TP54)<br />

1.5mL/min<br />

A: 15:75:10 Buffer/Methanol/n-Butanol<br />

B: 2:88:10 Buffer/Methanol/n-Butanol<br />

Buffer = Aqueous 0.02 M NH4OAc, pH 3.5<br />

100% A for 3min, then 0 to 100% B over 15min,<br />

then hold 100% B<br />

UV, programmed wavelengths<br />

0 1 2 3 4 5 6 7 8 Min.<br />

Column: Vydac ® 202TP C18, 5µm, 4.6 x 50mm<br />

(Part No. 202TP3405)<br />

Flow Rate: 3.0mL/min<br />

Mobile Phase: A: Water B: ACN<br />

Gradient: 40 to 95% B in 8min<br />

Column Temp: 30°C<br />

Detector: UV at 254nm<br />

Chromatogram reproduced with author’s permission. From W.A. MacCrehan and<br />

E. Schonberger, Clin. Chem., 33(9), 1585-1592 (1987).<br />

201TP C18 Analytical Columns<br />

Columns<br />

Recommended Guards<br />

Particle Size i.d. 50mm 100mm 150mm 250mm Guard Kit 1 Guard Cartridge 2<br />

5µm 1.0mm 201TP5105 — 201TP5115 201TP51 201GK51T 201GD51T<br />

2.1mm 201TP5205 201TP5210 201TP5215 201TP52 201GK52T 201GD52T<br />

3.2mm — — 201TP5315 201TP53 201GK54T 201GD54T<br />

4.6mm 201TP5405 201TP5410 201TP5415 201TP54 201GK54T 201GD54T<br />

10µm 4.6mm — — 201TP10415 201TP104 201GK104T 201GD104T<br />

1<br />

A guard kit includes a holder and one guard cartridge. 2 Guard cartridge units include two guard cartridges.<br />

202TP High-Carbon-Load C18 Analytical Columns<br />

Columns<br />

Recommended Guards<br />

Particle Size i.d. 50mm 100mm 150mm 250mm Guard Kit 1 Guard Cartridge 2<br />

3µm 3.2mm — — 202TP3315 — — —<br />

4.6mm 202TP3405 202TP3410 — — — —<br />

5µm 4.6mm — — 202TP5415 202TP54 202GK54T 202GD54T<br />

10µm 4.6mm 202TP10405 — — — 202GK104T 202GD104T<br />

1<br />

A guard kit includes a holder and one guard cartridge. 2 Guard cartridge units include two guard cartridges.<br />

www.discoverysciences.com 71


analytical hplc<br />

hplc columns | small molecule<br />

Astec Amino and<br />

Reversed-Phase Columns<br />

• Durable vinyl alcohol copolymer<br />

• Stable from pH 2–13<br />

• Stable and reproducible performance<br />

Choose Astec amino columns for separating mono- and<br />

oligosaccharides. Astec’s polymer base makes these columns<br />

much more stable than silica-based amino columns.<br />

Choose Astec reversed-phase columns for amines and high<br />

recoveries of proteins and peptides. Because there are no<br />

silanols, elution order is always based on hydrophobicity<br />

of the analytes rather than polar interactions with the base<br />

material. High recovery of proteins and peptides is typical<br />

even at low sample loads.<br />

1<br />

2<br />

3 4<br />

Mono-, Di-, and Trisaccharides<br />

5 6<br />

9103<br />

1. Rhamnose<br />

2. Fructose<br />

3. Glucose<br />

4. Sucrose<br />

5. Maltose<br />

6. Raffinose<br />

Astec Cyclobond Columns<br />

For Chiral Separations<br />

• Versatile chiral selectors<br />

• High-purity 5µm spherical silica<br />

Cyclodextrin Phases<br />

Designation<br />

Substituent<br />

I 2000<br />

β-Cyclodextrin<br />

I 2000 Ac<br />

β-Cyclodextrin Acetylate<br />

I 2000 RSP β-Cyclodextrin R,S-Hydroxypropyl Ether<br />

I 2000 DMP β-Cyclodextrin 3,5-Dimethylphenyl Carbamate<br />

II<br />

γ-Cyclodextrin<br />

Cyclobond I 2000 has the broadest applicability, and<br />

is ideal for small analytes in pharmaceutical, chemical,<br />

and environmental applications.<br />

Cyclobond 1 2000 Ac is ideal for aromatic alcohols<br />

or amines that are chiral on the alpha or beta carbon.<br />

Cyclobond I 2000 RSP is a general-purpose chiral<br />

stationary phase. It can separate non-aromatic structures<br />

such as t-boc amino acids.<br />

Cyclobond DMP shows good selectivity when the<br />

chiral centers are part of a ring structure or on the alpha<br />

carbon. This phase is ideal for derivatized amines such<br />

as amphetamine ACQ.<br />

Cyclobond II is useful for isomeric compounds based<br />

on anthracene, chrysene, and pyrene ring structures.<br />

Some applications include steroids, porphyrins, and FMOC<br />

amino acids.<br />

0<br />

10 20 30 Min.<br />

Column: Astec Amino, 5µm, 4.6 x 250mm (Part No. 16012)<br />

Mobile Phase: Acetonitrile:Water (75:25)<br />

Flow Rate: 1.0mL/min<br />

Detector: RI<br />

Astec Amino and Reversed-Phase 300Å Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 5µm Analytical 4.6 x 150mm 16004<br />

Analytical 4.6 x 250mm 16005<br />

C8, 5µm Analytical 4.6 x 150mm 16006<br />

Analytical 4.6 x 250mm 16007<br />

C4, 5µm Analytical 4.6 x 150mm 16008<br />

Analytical 4.6 x 250mm 16009<br />

Amino, 5µm Analytical 4.6 x 250mm 16012<br />

Astec Amino and Reversed-Phase Guard Columns<br />

Packing i.d. x Length Qty. Part No.<br />

C18, 5µm 4.6 x 10mm ea 28180<br />

C8, 5µm 4.6 x 10mm ea 28181<br />

C4, 5µm 4.6 x 10mm ea 28182<br />

Amino, 5µm 4.6 x 10mm ea 28187<br />

Astec Cyclobond Columns<br />

Packing Format i.d. x Length Part No.<br />

I 2000, 5µm Analytical 4.6 x 100mm 400101<br />

Analytical 4.6 x 250mm 410101<br />

I 2000 Ac, 5µm Analytical 4.6 x 250mm 410121<br />

I 2000 RSP, 5µm Analytical 4.6 x 250mm 411121<br />

I 2000 DMP, 5µm Analytical 4.6 x 250mm 412111<br />

II Analytical 4.6 x 100mm 400201<br />

Analytical 4.6 x 250mm 410201<br />

Astec Cyclobond Guard Cartridges*<br />

Packing, i.d. x Length Qty. Part No.<br />

I 2000, 5µm 4.0 x 20mm ea 430102<br />

I 2000 Ac, 5µm 4.0 x 20mm ea 430103<br />

I 2000 RSP, 5µm 4.0 x 20mm ea 430105<br />

I 2000 DMP, 5µm 4.0 x 20mm ea 430108<br />

II 4.0 x 20mm ea 430109<br />

Astec Guard Cartridge Holder ea 11014<br />

*Guard holder required.<br />

72<br />

www.discoverysciences.com


analytical hplc<br />

Astec Chirobiotic <br />

HPLC Columns<br />

For Multi-Mode Chiral Separations<br />

• Bonded macrocyclic glycopeptide phases<br />

• Three complimentary selectivities<br />

• High-purity 5µm spherical silica<br />

Chirobiotic columns demonstrate a broad selectivity in<br />

reversed phase, normal phase, and polar organic modes.<br />

This gives Chirobiotic columns the ability to separate a<br />

greater variety of chiral analytes than columns that can only<br />

operate in one mode.<br />

Chirobiotic V<br />

Chirobiotic V Specifications<br />

Ligand: Vancomycin<br />

Ideal For: Neutral molecules, amides, acids, esters, cyclic amines<br />

Chirobiotic V has a selectivity similar to glycoprotein phases<br />

while also being stable from 0–100% organic modifiers. New<br />

Chirobiotic V2 has enhanced selectivity and capacity in the<br />

polar organic mode, and increased capacity.<br />

Naproxen<br />

8769<br />

CH 3<br />

CHCOH<br />

O<br />

H 3 CO<br />

6 8 10 12 Min.<br />

Column: Chirobiotic V, 4.6 x 250mm (Part No. 11024)<br />

Mobile Phase: THF:0.1% Triethylammonium Acetate, pH 7 (10:90)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Phenylalanine<br />

8770<br />

O<br />

hplc columns | small molecule<br />

Chirobiotic T<br />

Chirobiotic T Specifications<br />

Ligand: Teicoplanin<br />

Ideal For: Underivatized amino acids, n-derivatized amino acids,<br />

carboxylic acids, phenols, neutral aromatics, cyclic aromatics<br />

with aliphatic amines<br />

Chirobiotic T is an excellent alternative to crown ether and<br />

ligand exchange for amino acids and hydroxy acids. New<br />

Chirobiotic T2 has enhanced selectivity and capacity in the<br />

polar organic mode.<br />

Chirobiotic R<br />

Chirobiotic R Specifications<br />

Ligand: Ristocetin A<br />

Ideal For: Anionic molecules, di- and tri-peptides, α-hydroxy acids,<br />

substituted aliphatic acids, aromatic esters, chiral alcohols,<br />

secondary and tertiary amines<br />

Chirobiotic R is the largest and most complex of the<br />

Chirobiotic ligands. Sugar moieties, a peptide chain, and<br />

additional ionizable groups give this structure the complexity<br />

and diversity to separate a wide variety of analytes.<br />

4 6 8 10 12 Min.<br />

NH 2<br />

Column: Chirobiotic T, 4.6 x 250mm (Part No. 12053)<br />

Mobile Phase: Ethanol:Water (80:20)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 210nm<br />

Astec Chirobiotic Columns<br />

Packing Format i.d. x Length Part No.<br />

Chirobiotic V Analytical 4.6 x 50mm 11346<br />

Analytical 4.6 x 150mm 11023<br />

Analytical 4.6 x 250mm 11024<br />

Chirobiotic V2 Analytical 4.6 x 100mm A15022<br />

Analytical 4.6 x 150mm A15023<br />

Analytical 4.6 x 250mm A15024<br />

Prep 10 x 250mm A15034<br />

Prep 21.2 x 250mm A15044<br />

Chirobiotic T Analytical 4.6 x 50mm 11349<br />

Analytical 4.6 x 150mm 12051<br />

Analytical 4.6 x 250mm 12053<br />

Chirobiotic T2 Analytical 4.6 x 100mm A16022<br />

Analytical 4.6 x 150mm A16023<br />

Analytical 4.6 x 250mm A16024<br />

Prep 10 x 250mm A16034<br />

Prep 21.2 x 250mm A16044<br />

Chirobiotic R Analytical 4.6 x 50mm 12514<br />

Analytical 4.6 x 150mm 12516<br />

Analytical 4.6 x 250mm 12518<br />

Astec Chirobiotic Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

Chirobiotic V, 5µm 4.0 x 20mm ea 11019<br />

Chirobiotic T, 5µm 4.0 x 20mm ea 12445<br />

Chirobiotic R, 5µm 4.0 x 20mm ea 12522<br />

Astec Guard Cartridge Holder ea 11014<br />

*Guard holder required.<br />

OH<br />

www.discoverysciences.com 73


analytical hplc<br />

hplc columns | small and large molecule<br />

74<br />

Brownlee Columns<br />

Economical MPLC Cartridge System with<br />

Reusable Hardware<br />

• Finger-tight modular design<br />

• Reusable end assemblies with interchangeable holders<br />

• Guards fit conventional columns or MPLC hardware<br />

The Brownlee MPLC Cartridge system is convenient<br />

and easy to use. Decide which column length you prefer,<br />

and purchase the hardware and the disposable packed<br />

cartridges separately.<br />

Cartridge Hardware<br />

Brownlee MPLC Cartridge Hardware<br />

Photo Description Part No.<br />

MPLC Cartridge Holders<br />

30mm 140200<br />

5424<br />

MPLC Cartridge Accessories<br />

0647B<br />

Brownlee MPLC NewGuard Hardware<br />

Photo Description Part No.<br />

NewGuard Cartridge 140601<br />

Holders NewGuard Holder<br />

0647E for use with Conventional<br />

Columns<br />

220mm NewGuard 140410<br />

System Holder for Direct<br />

Coupling of 220mm<br />

0647F<br />

Analytical Cartridge with a<br />

NewGuard Cartridge<br />

NewGuard End Assembly 140600<br />

www.discoverysciences.com<br />

100mm 140230<br />

220mm 140400<br />

MPLC Cartridge Union 140300<br />

MPLC Cartridge End 1402501<br />

0647C Assembly<br />

MPLC Cartridge Holder Bodies<br />

30mm 140203<br />

0647D<br />

100mm 140003<br />

220mm 140403<br />

Universal MPLC Cartridge Holder Kit<br />

Includes: 30-, 100-, and 220mm MPLC Cartridge Holder<br />

Bodies (E), 1 MPLC Cartridge Union (C), 2 End Assemblies<br />

(D), and 1 NewGuard End Assembly (H)<br />

Brownlee MPLC Cartridge Hardware Seals<br />

Description<br />

Analytical Holder Seal Replacement Kit<br />

Includes Tool and 2 Seals<br />

Analytical Seals, 2/pk<br />

Seal Replacement Tool Required<br />

NewGuard System<br />

0647G<br />

0647A<br />

140530<br />

Part No.<br />

140260<br />

140216<br />

Brownlee NewGuard Cartridges*<br />

Description Qty. Part No.<br />

RP-18 3 141004<br />

RP-8 3 141003<br />

Cyano 3 141008<br />

Amino 3 141007<br />

Silica 3 141012<br />

Anion (AX-300) 3 141009<br />

*NewGuard cartridge holder required (Part No. 140601).<br />

Spheri-5 and Spheri-10 Cartridges<br />

• Rugged and reproducible<br />

• Use with MPLC cartridge hardware<br />

• 80Å, spherical silica<br />

RP-18 and RP-8 phases are monomeric for optimum mass<br />

transfer kinetics and high efficiency. The ODS phase is<br />

polymeric and more suitable for acidic mobile phases.<br />

Brownlee Spheri-5 Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

ODS (C18), 5µm 2.1 x 30mm 2 141061<br />

2.1 x 100mm ea 141063<br />

2.1 x 220mm ea 141065<br />

4.6 x 30mm 2 141060<br />

4.6 x 100mm ea 141062<br />

4.6 x 220mm ea 141064<br />

RP-18, 5µm 2.1 x 30mm 2 141052<br />

2.1 x 100mm ea 141054<br />

2.1 x 220mm ea 141056<br />

4.6 x 100mm ea 141053<br />

4.6 x 220mm ea 1410551<br />

RP-8, 5µm 2.1 x 30mm 2 141028<br />

2.1 x 100mm ea 141030<br />

2.1 x 220mm ea 141032<br />

4.6 x 30mm 2 141027<br />

4.6 x 100mm ea 141029<br />

4.6 x 220mm ea 141031<br />

Cyano, 5µm 4.6 x 30mm 2 141083<br />

4.6 x 100mm ea 141085<br />

4.6 x 220mm ea 141087<br />

Amino, 5µm 4.6 x 30mm 2 141177<br />

4.6 x 100mm ea 141179<br />

4.6 x 220mm ea 141181<br />

Silica, 5µm 2.1 x 30mm 2 141194<br />

4.6 x 30mm 2 141193<br />

4.6 x 100mm ea 141195<br />

4.6 x 220mm ea 141197<br />

*Brownlee MPLC cartridge holder required.<br />

Brownlee Spheri-10 Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

RP-18, 10µm 4.6 x 30mm 2 141043<br />

4.6 x 100mm ea 1410451<br />

RP-8, 10µm 4.6 x 30mm 2 141020<br />

4.6 x 100mm ea 141022<br />

Silica, 10µm 4.6 x 30mm 2 141186<br />

*Brownlee MPLC cartridge holder required.<br />

Aquapore DEAE WAX Cartridges<br />

• Large pore for macromolecules<br />

Choose AX-300 with its DEAE functional group for weak anion<br />

exchange applications with proteins and peptides.<br />

Brownlee Aquapore Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

AX-300, 7µm 4.6 x 30mm 2 141212<br />

4.6 x 100mm ea 141214<br />

*Brownlee MPLC cartridge holder required.


analytical hplc<br />

Jordi Columns<br />

Normal- and Reversed-Phase<br />

• Rugged—use at high temperatures, from pH 0–14,<br />

with any solvent<br />

• Silanol Free—analyze polar compounds without<br />

silanol effects<br />

Jordi normal-phase and reversed-phase columns are<br />

made from highly pure 5µm DVB, for extremely durable<br />

and efficient phases.<br />

Jordi Specifications<br />

Phase Particle Size Pore Size Description<br />

RP-DVB 5µm 500Å, 1000Å Reversed-phase,<br />

not bonded<br />

C18-DVB 5µm 500Å Reversed-phase,<br />

C18 bonded<br />

Polyamine-DVB 5µm 500Å Normal-phase<br />

RP-DVB<br />

RP-DVB is a reversed-phase non-polar packing with a high<br />

degree of aromatic character. SM-500, with a 500Å pore, is<br />

recommended for most applications. LM-1000, with a 1000Å<br />

pore, is ideal for molecules 100,000 Daltons or larger.<br />

C18-DVB<br />

C18-DVB has C18 chains bonded to the DVB base. These<br />

columns are more hydrophobic than traditional C18 columns<br />

and have different selectivities due to the absence of silanols.<br />

Polyamine-DVB<br />

Polyamine-DVB is a normal-phase column for simple sugar<br />

and polysaccharide applications. The DVB-based packing<br />

provides a non-reactive amine surface that lasts longer and<br />

equilibrates faster than traditional silica-based amine columns.<br />

Polyamine-DVB columns can be used with aqueous mobile<br />

phases, even 1M NaOH. Ideal for carbohydrate analyses<br />

requiring sharp peaks and short run times.<br />

Jordi HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

RP-DVB (SM-500Å), 5µm Analytical 4.6 x 150mm 1005500<br />

Analytical 4.6 x 250mm 1005520<br />

RP-DVB (LM-1000Å), 5µm Analytical 4.6 x 150mm 1005580<br />

Analytical 4.6 x 250mm 1005585<br />

C18-DVB (500Å), 5µm Analytical 4.6 x 150mm 18500<br />

Analytical 4.6 x 250mm 18501<br />

Polyamine-DVB (500Å), 5µm Analytical 4.6 x 250mm 1005900<br />

Jordi All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

RP-DVB (SM-500Å), 5µm 4.6 x 7.5mm 3 1005595<br />

RP-DVB (LM-1000Å), 5µm 4.6 x 7.5mm 3 1005596<br />

C18-DVB (500Å), 5µm 4.6 x 7.5mm 3 1005601<br />

Polyamine-DVB (500Å), 5µm 4.6 x 7.5mm 3 1005615<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

related product<br />

Looking for column heaters?<br />

See pages 16 and 17.<br />

GPC Columns<br />

Organic GPC<br />

• Rugged—highly crosslinked DVB for broad temperature<br />

stability and solvent compatibility<br />

• Powerful—high pore volume for greater resolution from<br />

a single column<br />

Jordi Organic and Aqueous GPC Specifications<br />

Pore Size Pressure Limit MW Range (Daltons)<br />

100Å 8000psig 100–5000<br />

500Å 8000psig 100–10,000<br />

103Å 8000psig 100–25,000<br />

104Å 2000psig 100–2,000,000<br />

105Å 2000psig 10,000–10,000,000<br />

Mixed Bed 2000psig 100–>10,000,000<br />

Jordi HPLC columns, offer unparalleled resistance to<br />

shrinking and swelling, as well as better temperature and<br />

solvent compatibility than traditional ps-DVB phases.<br />

The high pore volume speeds up your analyses. A single<br />

10 x 500mm Jordi column replaces three 7.8 x 300mm ps-DVB<br />

columns and separates the same sample in 40% less time.<br />

Aqueous GPC<br />

Glucose-DVB packings are rugged, hydrophilic packings for<br />

separating polar compounds. Glucose units are bonded to<br />

the DVB base to yield a hydrophilic surface. Glucose-DVB<br />

columns equilibrate faster than silica-based columns.<br />

Jordi Organic GPC Columns*<br />

Pore Size Format i.d. x Length Part. No.<br />

100Å, 5µm Semi Prep 7.8 x 300mm 10510<br />

Prep 10 x 250mm 100561<br />

500Å, 5µm Semi Prep 7.8 x 300mm 10511<br />

Prep 10 x 250mm 100565<br />

Prep 10 x 500mm 100567<br />

103Å, 5µm Semi Prep 7.8 x 300mm 10512<br />

Prep 10 x 250mm 100569<br />

104Å, 5µm Semi Prep 7.8 x 300mm 10513<br />

Prep 10 x 250mm 100573<br />

105Å, 5µm Semi Prep 7.8 x 300mm 10514<br />

Prep 10 x 250mm 100577<br />

Mixed-Bed Linear, 5µm Semi Prep 7.8 x 300mm 10515<br />

Prep 10 x 250mm 100581<br />

Prep 10 x 500mm 100583<br />

*Jordi GPC columns are constructed from Type 316 stainless steel. All tubing<br />

connections are 1/16" female. Columns are shipped in Chloroform unless otherwise<br />

requested when placing order.<br />

Jordi Aqueous GPC Columns<br />

Pore Size Format i.d. x Length Part No.<br />

100Å, 5µm Semi Prep 7.8 x 300mm 10517<br />

Prep 10 x 250mm 100761<br />

500Å, 5µm Semi Prep 7.8 x 300mm 10518<br />

Prep 10 x 250mm 100765<br />

103Å, 5µm Semi Prep 7.8 x 300mm 10519<br />

Prep 10 x 250mm 100769<br />

104Å, 5µm Semi Prep 7.8 x 300mm 10520<br />

Prep 10 x 250mm 100773<br />

105Å, 5µm Semi Prep 7.8 x 300mm 10521<br />

Prep 10 x 250mm 100777<br />

Mixed-Bed Linear, 5µm Semi Prep 7.8 x 300mm 10522<br />

Prep 10 x 250mm 100781<br />

Prep 10 x 500mm 100783<br />

hplc columns | small and large molecule<br />

6219<br />

www.discoverysciences.com 75


analytical hplc<br />

hplc columns | small molecule<br />

Merck LiChrosorb ® and LiChrospher ® Columns<br />

• LiChrosorb ® —irregular silica for larger surface areas<br />

• LiChrospher ® —spherical silica for higher stability<br />

and reproducibility<br />

All Merck columns are packed by <strong>Grace</strong> to our highest<br />

QC standards. Custom columns are available.<br />

LiChrosorb ® HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

RP-18, 5µm Solvent Reducer 3.0 x 150mm 38513<br />

Solvent Reducer 3.0 x 250mm 38514<br />

Analytical 4.6 x 250mm 8684<br />

RP Select B, 5µm Analytical 4.6 x 150mm 228700<br />

Analytical 4.6 x 250mm 228685<br />

RP-8, 5µm Solvent Reducer 3.0 x 150mm 38515<br />

Solvent Reducer 3.0 x 250mm 38516<br />

Analytical 4.6 x 250mm 8692<br />

Amino, 5µm Analytical 4.6 x 250mm 228872<br />

Si-60, 10µm Analytical 4.6 x 250mm 8369<br />

Si-100, 10µm Analytical 4.6 x 250mm 8720<br />

Melatonin<br />

0 2 4 6 8 Min.<br />

1<br />

Column: LiChrospher ® RP-18, 5µm, 4.6 x 150mm<br />

(Part No. 228695)<br />

Mobile Phase: 25mM KH2PO4, pH2.75:MeOH (60:40)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

9055<br />

1. Melatonin<br />

Alltech ® All-Guard<br />

System—change cartridges<br />

in seconds without tools.<br />

LiChrospher ® HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

RP-18, 3µm Analytical 4.6 x 150mm 228688<br />

RP-18, 5µm Analytical 4.6 x 150mm 228695<br />

Analytical 4.6 x 250mm 228673<br />

RP-18 EC, 3µm Analytical 4.6 x 150mm 228686<br />

RP-18 EC, 5µm Analytical 4.6 x 150mm 228694<br />

Analytical 4.6 x 250mm 228672<br />

RP-8, 5µm Analytical 4.6 x 150mm 228696<br />

Analytical 4.6 x 250mm 228675<br />

RP-8 EC , 5µm Analytical 4.6 x 150mm 228697<br />

Analytical 4.6 x 250mm 228678<br />

RP-Select B, 5µm Analytical 4.6 x 150mm 228611<br />

Analytical 4.6 x 250mm 228613<br />

Amino, 5µm Analytical 4.6 x 150mm 228693<br />

Analytical 4.6 x 250mm 228670<br />

Diol-100, 5µm Analytical 4.6 x 150mm 228691<br />

Analytical 4.6 x 250mm 228666<br />

Si-60, 5µm Analytical 4.6 x 150mm 228699<br />

Analytical 4.6 x 250mm 228683<br />

1656<br />

LiChrosorb ® All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

RP-18, 5µm 3.0 x 7.5mm 3 96374<br />

4.6 x 7.5mm 3 96171<br />

RP-Select B, 5µm 4.6 x 7.5mm 3 96181<br />

RP-8, 5µm 3.0 x 7.5mm 3 96373<br />

4.6 x 7.5mm 3 96173<br />

Amino, 5µm 4.6 x 7.5mm 3 96175<br />

Silica, 5µm 4.6 x 7.5mm 3 96201<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

LiChrospher ® All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

RP-18, 5µm 4.6 x 7.5mm 3 96185<br />

RP-18 Endcapped, 5µm 4.6 x 7.5mm 3 96183<br />

RP-8, 5µm 4.6 x 7.5mm 3 96189<br />

RP-8 Endcapped, 5µm 4.6 x 7.5mm 3 96187<br />

RP Select B, 5µm 4.6 x 7.5mm 3 96425<br />

Amino, 5µm 4.6 x 7.5mm 3 96191<br />

Diol, 5µm 4.6 x 7.5mm 3 96195<br />

Silica, 5µm 4.6 x 7.5mm 3 96201<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

76<br />

www.discoverysciences.com


analytical hplc<br />

Macherey-Nagel Nucleosil ® Columns<br />

• 100Å, high-purity silica<br />

• Narrow particle size distribution<br />

• A choice of phases for any application<br />

All Nucleosil ® columns are packed by <strong>Grace</strong> to our highest<br />

QC standards.<br />

C18 AB is polymerically bonded specifically for reversedphase<br />

chromatography of acidic and basic compounds.<br />

It has a 25% carbon load for strong retention.<br />

1<br />

0 1<br />

2<br />

3<br />

4<br />

2<br />

SRM 869<br />

3<br />

5 6 7 8 9 Min.<br />

Column: Nucleosil ® C18 AB, 5µm, 4.6 x 150mm<br />

(Part No. 11652)<br />

Mobile Phase: (85:15) Acetonitrile:Water<br />

Flow Rate: 2.0mL/min<br />

Detector: UV at 254nm<br />

Column Temp: 25°C<br />

4<br />

9320<br />

1. Acetone<br />

2. Phenanthroanthrene<br />

3. 1,2:3,4:5,6:7,<br />

8-Tetrabenzonaphthalene<br />

4. Benzo[a]pyrene<br />

Nucleosil ® HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

C18, 3µm Analytical 4.6 x 100mm 89531 89532<br />

Analytical 4.6 x 150mm 89511 89512<br />

C18, 5µm Analytical 4.6 x 150mm 89161 89162<br />

Analytical 4.6 x 250mm 89141 89142<br />

C18, 10µm Analytical 4.6 x 250mm 89121 89122<br />

C18 AB, 5µm Analytical 4.6 x 150mm 11652 —<br />

Analytical 4.6 x 250mm 11657 —<br />

C8, 5µm Analytical 4.6 x 150mm 89221 89222<br />

Analytical 4.6 x 250mm 89201 89202<br />

C8, 10µm Analytical 4.6 x 250mm 89181 89182<br />

Phenyl, 7µm Analytical 4.6 x 150mm 89261 89262<br />

Analytical 4.6 x 250mm 89241 89242<br />

Cyano, 5µm Analytical 4.6 x 150mm 89321 89322<br />

Analytical 4.6 x 250mm 89301 89302<br />

Cyano, 10µm Analytical 4.6 x 250mm 89281 89282<br />

Amino, 5µm Analytical 4.6 x 150mm 89381 89382<br />

Analytical 4.6 x 250mm 89361 89362<br />

Amino, 10µm Analytical 4.6 x 250mm 89341 89342<br />

Silica, 5µm Analytical 4.6 x 150mm 89441 89442<br />

Analytical 4.6 x 250mm 89421 89422<br />

Silica, 10µm Analytical 4.6 x 250mm 89401 89402<br />

SA, 5µm Analytical 4.6 x 150mm 228498 228504<br />

Analytical 4.6 x 250mm 228497 228503<br />

SA, 10µm Analytical 4.6 x 250mm 228496 228502<br />

SB, 5µm Analytical 4.6 x 150mm 228501 228507<br />

Analytical 4.6 x 250mm 228500 228506<br />

SB, 10µm Analytical 4.6 x 250mm 228499 228505<br />

hplc columns | small molecule<br />

Opium Alkaloids<br />

5243<br />

Alltech ® All-Guard<br />

System—change cartridges<br />

in seconds without tools.<br />

1<br />

2<br />

3<br />

4<br />

0 4 8 12 16 Min.<br />

5<br />

6<br />

Column: Nucleosil ® CN, 10µm, 4.6 x 250mm<br />

(Part No. 89281)<br />

Mobile Phase: 80%15mM Ammonium Acetate pH 5.8<br />

10% Acetonitrile 10% Dioxane<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 210nm<br />

Column Temp: Ambient<br />

1. Morphine<br />

2. Codeine<br />

3. Cryptopine<br />

4. Thebaine<br />

5. Narcotine<br />

6. Papaverine<br />

Nucleosil ® All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

C18, 5µm 4.6 x 7.5mm 3 96210<br />

C8, 5µm 4.6 x 7.5mm 3 96211<br />

Phenyl, 5µm 4.6 x 7.5mm 3 96214<br />

Cyano, 5µm 4.6 x 7.5mm 3 96213<br />

Amino, 5µm 4.6 x 7.5mm 3 96212<br />

Silica, 5µm 4.6 x 7.5mm 3 96215<br />

SA, 5µm 4.6 x 7.5mm 3 89340<br />

SB, 5µm 4.6 x 7.5mm 3 89345<br />

All-Guard Cartridge Holder<br />

(Includes Direct-Connect Column Coupler)<br />

ea 80101<br />

1656<br />

*All-Guard holder required. Other particle sizes available.<br />

more info<br />

For more HPLC Applications, see pages 395–453.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

www.discoverysciences.com 77


analytical hplc<br />

hplc columns | small molecule<br />

Whatman Partisil Columns<br />

All Whatman Partisil columns are packed by <strong>Grace</strong> to our<br />

highest QC standards. Partisil ® columns use 85Å, irregular<br />

silica with a surface area of 350m 2 /g.<br />

Partisil PAC is a polar amino cyano phase with secondary<br />

amino groups for thermal and chemical stability. It separates<br />

primarily by reversed-phase or weak anion exchange.<br />

Partisil HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Waters ®<br />

Fittings<br />

Part No.<br />

ODS, 10µm Analytical 4.6 x 250mm 8246 8247<br />

ODS-2, 5µm Analytical 4.6 x 250mm 12571 12572<br />

ODS-2, 10µm Analytical 4.6 x 250mm 8251 8252<br />

ODS-3, 5µm Analytical 4.6 x 250mm 8660 8662<br />

ODS-3, 10µm Analytical 4.6 x 250mm 8256 8257<br />

C8, 5µm Analytical 4.6 x 250mm 8668 8670<br />

C8, 10µm Analytical 4.6 x 250mm 8380 8381<br />

PAC, 5µm Analytical 4.6 x 250mm 8676 8678<br />

PAC, 10µm Analytical 4.6 x 250mm 8261 8262<br />

Silica, 5µm Analytical 4.6 x 250mm 8266 8267<br />

Silica, 10µm Analytical 4.6 x 250mm 8271 8272<br />

SAX, 5µm Analytical 4.6 x 250mm 12576 12577<br />

SAX, 10µm Analytical 4.6 x 250mm 8165 8167<br />

SCX, 10µm Analytical 4.6 x 250mm 8173 8175<br />

Partisil All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

ODS, 5µm 4.6 x 7.5mm 3 96252<br />

ODS-2, 5µm 4.6 x 7.5mm 3 96253<br />

ODS-3, 5µm 4.6 x 7.5mm 3 96254<br />

C8, 5µm 4.6 x 7.5mm 3 96255<br />

PAC, 5µm 4.6 x 7.5mm 3 96256<br />

Silica, 5µm 4.6 x 7.5mm 3 96257<br />

SAX, 5µm 4.6 x 7.5mm 3 96259<br />

SCX, 5µm 4.6 x 7.5mm 3 96258<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

Whatman Partisphere ®<br />

WVS Columns<br />

Whatman’s Partisphere ® WVS columns have built-in void<br />

compensators that help you extend the column lifetime.<br />

Use the piston-like plungers at each end of the column to<br />

compress the bed and seal any voids that develop over time.<br />

Choose your column from the table below, and purchase<br />

reusable WVS endfittings separately.<br />

Partisphere ® WVS HPLC Cartridges*<br />

Packing Format i.d. x Length Part No.<br />

C18, 5µm Analytical 4.6 x 125mm 46210502<br />

C8, 5µm Analytical 4.6 x 125mm 46210503<br />

PAC, 5µm Analytical 4.6 x 125mm 46210508<br />

Silica, 5µm Analytical 4.6 x 125mm 46210501<br />

SAX, 5µm Analytical 4.6 x 125mm 46210505<br />

SCX, 5µm Analytical 4.6 x 125mm 46210507<br />

WVS Reusable Endfittings, 2/pk 46310001<br />

*Reusable endfittings required.<br />

Partisphere ® WVS Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

C18/C8, 5µm 5 x 17mm 5 46410002<br />

PAC, 5µm 5 x 17mm 5 46410008<br />

Silica, 5µm 5 x 17mm 5 46410001<br />

SAX, 5µm 5 x 17mm 5 46410005<br />

SCX, 5µm 5 x 17mm 5 46410007<br />

Guard Cartridge Holder 19 x 40mm ea 46311004<br />

*Guard holder required.<br />

more info<br />

For HPLC Applications, see pages 395–453.<br />

related products<br />

Need HPLC tubing?<br />

See pages 384–391.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

related products<br />

Looking for high-pressure fittings?<br />

See pages 112–118.<br />

5535<br />

6673<br />

78<br />

www.discoverysciences.com


analytical hplc<br />

Polymer Labs Columns<br />

Outstanding Durability and Stability<br />

• Ideal for elevated temperature and pressure applications<br />

• Stable from pH 1–13<br />

PLRP-S is a polystyrene divinylbenzene copolymer designed<br />

specifically for reversed-phase HPLC. PLRP-S columns are<br />

extremely stable, performing over a wide pH range and at<br />

elevated temperatures and pressures.<br />

PLRP-S Choice of Pore Sizes:<br />

• 100Å for small molecules, peptides, and nucleotides<br />

• 300Å for polypeptides and globular proteins<br />

• 1000Å for fibrous proteins<br />

• 4000Å for the analysis of very large biomolecules or<br />

high-speed/high-resolution separations<br />

PLRP-S HPLC Specifications<br />

Base Material<br />

Polystyrene Divinylbenzene<br />

Organic Modifier 0 to 100%<br />

Particle Size 3, 5, 8, 10µm<br />

Pore Size<br />

100, 300, 1000, 4000Å<br />

pH Range 1–13<br />

Max. Temp. 80ºC<br />

Max. Pressure<br />

3000psig<br />

Max. Flow Rate<br />

4mL/min<br />

1<br />

2<br />

4<br />

3<br />

0 2 4 6 8 10 12 Min.<br />

Column:<br />

Mobile Phase:<br />

Gradient:<br />

Flow Rate:<br />

Detector:<br />

Enkephalins<br />

5<br />

PLRP-S 100Å, 5µm, 4.6 x 250mm<br />

(Part No. 1512-5500)<br />

A: 0.1% TFA, 1% IPA in Water<br />

B: 0.1% TFA, 1% IPA in ACN<br />

Linear 15 – 85% B in 15min<br />

1.0mL/min<br />

UV at 220nm<br />

7253<br />

1. Methionine Enkephalin Sulphoxide<br />

2. Methionine Enkephalin Lysine<br />

3. Methionine Enkephalin<br />

4. D-ALA2 Methionine Enkephalin<br />

5. D-TRP Methionine Enkephalin<br />

PLRP-S HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

100Å, 3µm Microbore 2.1 x 50mm 1912-1300<br />

Microbore 2.1 x 150mm 1912-3300<br />

Analytical 4.6 x 50mm 1512-1300<br />

Analytical 4.6 x 150mm 1512-3300<br />

100Å, 5µm Microbore 2.1 x 50mm 1912-1500<br />

Microbore 2.1 x 150mm 1912-3500<br />

Microbore 2.1 x 250mm 1912-5500<br />

Analytical 4.6 x 50mm 1512-1500<br />

Analytical 4.6 x 150mm 1512-3500<br />

Analytical 4.6 x 250mm 1512-5500<br />

100Å, 8µm Analytical 4.6 x 150mm 1512-3800<br />

Analytical 4.6 x 250mm 1512-5800<br />

300Å, 3µm Microbore 2.1 x 50mm 1912-1301<br />

Microbore 2.1 x 150mm 1912-3301<br />

Analytical 4.6 x 50mm 1512-1301<br />

Analytical 4.6 x 150mm 1512-3301<br />

300Å, 5µm Microbore 2.1 x 50mm 1912-1501<br />

Microbore 2.1 x 150mm 1912-3501<br />

Microbore 2.1 x 250mm 1912-5501<br />

Analytical 4.6 x 50mm 1512-1501<br />

Analytical 4.6 x 150mm 1512-3501<br />

Analytical 4.6 x 250mm 1512-5501<br />

300Å, 8µm Analytical 4.6 x 150mm 1512-3801<br />

Analytical 4.6 x 250mm 1512-5801<br />

1000Å, 5µm Microbore 2.1 x 50mm 1912-1502<br />

Analytical 4.6 x 50mm 1512-1502<br />

1000Å, 8µm Microbore 2.1 x 50mm 1912-1802<br />

Microbore 2.1 x 150mm 1912-3802<br />

Analytical 4.6 x 50mm 1512-1802<br />

Analytical 4.6 x 150mm 1512-3802<br />

Analytical 4.6 x 250mm 1512-5802<br />

4000Å, 5µm Microbore 2.1 x 50mm 1912-1503<br />

Analytical 4.6 x 50mm 1512-1503<br />

4000Å, 8µm Microbore 2.1 x 50mm 1912-1803<br />

Microbore 2.1 x 150mm 1912-3803<br />

Analytical 4.6 x 50mm 1512-1803<br />

Analytical 4.6 x 150mm 1512-3803<br />

PLRP-S Guard Columns<br />

Packing i.d. x Length Qty. Part No.<br />

PLRP-S, 5µm 3 x 5mm 2 1512-1503<br />

Guard Column Holder ea 1310-0016<br />

more info<br />

For more large molecule columns, see pages 84–97.<br />

related product<br />

Looking for column heaters?<br />

See page 16–17.<br />

hplc columns | small and large molecule<br />

6219<br />

www.discoverysciences.com 79


analytical hplc<br />

hplc columns | small and large molecule<br />

Shodex ® Columns<br />

Aqueous Size Exclusion<br />

• High efficiency and high mass recovery<br />

• Separate biopolymers by their effective size in solution<br />

• Stable sugar GFC columns<br />

Shodex ® Ohpak and Sugar columns are designed for highresolution<br />

separations of water-soluble compounds such as<br />

organics, inorganics, oligomers, and polymers. Three different<br />

gel filtration size exclusion materials are available.<br />

Shodex ® Sugar columns use a sulfonated gel with a<br />

sodium counter ion for separation of mono, di, oligo, and<br />

polysaccharides, starches, and celluloses.<br />

Proteins by GFC<br />

1<br />

2 3 4 5<br />

9162<br />

1. Glutamate Dehydrogenase (290k)<br />

2. Lactate Dehydrogenase (142k)<br />

3. Enolase (67k)<br />

4. Adenylate Kinase (32k)<br />

5. Cytochrome (12.4k)<br />

Aqueous Size Exclusion Columns<br />

Packing Series Description Applications<br />

OHpak SB-800 Polyhydroxymethacrylate General purpose GFC of<br />

water-soluble polymers,<br />

proteins, and enzymes<br />

Protein KW-800 Porous Silica Gel GFC of proteins,<br />

glycoproteins, and peptides<br />

Sugar KS-800<br />

1<br />

Sulfonated PS Gel<br />

(Na+ counter ion)<br />

2<br />

3 4 5<br />

6<br />

Separation of mono, di,<br />

oligo, and polysaccharides,<br />

starches, and celluloses<br />

Pullulan, Saccharides, and Ethanol<br />

9163<br />

1. Pullulan (46.7k)<br />

2. Pullulan (5.3k)<br />

3. Raffinose<br />

4. Sucrose<br />

5. Fructose<br />

6. Ethanol<br />

0 5<br />

10 15 Min.<br />

0 2<br />

4 6 8 10 12 Min.<br />

Column: Shodex ® Protein KW-803, 8.0 x 300mm<br />

(Part No. 5749)<br />

Mobile Phase: 50mM Phosphate buffer + 0.3M NaCl, pH 7.0<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column Temp: 28°C<br />

Column: Shodex ® Sugar KS-802, 8.0 x 300mm<br />

(Part No. 5743)<br />

Mobile Phase: Water<br />

Flow Rate: 1.0mL/min<br />

Detector: RI<br />

Column Temp: 80°C<br />

Shodex ® Size Exclusion HPLC Columns<br />

Particle Size Format Packing MW Range i.d. x Length Part No.<br />

OHpak 8µm Analytical Q-801 50–1800 8.0 x 500mm 5737<br />

8µm Analytical SB-802 HQ 50–4000 8.0 x 300mm 5730<br />

6µm Analytical SB-802.5 HQ 50–10,000 8.0 x 300mm 5731<br />

6µm Analytical SB-803 HQ 50–100,000 8.0 x 300mm 5732<br />

10µm Analytical SB-804 HQ 100–1,000,000 8.0 x 300mm 5733<br />

13µm Analytical SB-805 HQ 500–4,000,000 8.0 x 300mm 5734<br />

13µm Analytical SB-806M HQ 100–20,000,000 8.0 x 300mm 5736<br />

Protein 5µm Analytical KW-802.5 50–50,000 8.0 x 300mm 5748<br />

5µm Analytical KW-803 50–150,000 8.0 x 300mm 5749<br />

7µm Analytical KW-804 100–600,000 8.0 x 300mm 5750<br />

Sugar 5µm Analytical KS-801 50–1000 8.0 x 300mm 5742<br />

5µm Analytical KS-802 50–10,000 8.0 x 300mm 5743<br />

5µm Analytical KS-803 50–50,000 8.0 x 300mm 5744<br />

7µm Analytical KS-804 100–400,000 8.0 x 300mm 5745<br />

17µm Analytical KS-805 100–5,000,000 8.0 x 300mm 5746<br />

17µm Analytical KS-806 500–50,000,000 8.0 x 300mm 5747<br />

related product<br />

Doing carbohydrate analysis?<br />

ELSD offers greater sensitivity than RI. See pages 5–11.<br />

related product<br />

Looking for column heaters?<br />

See pages 16 and 17.<br />

80<br />

www.discoverysciences.com<br />

6219


analytical hplc<br />

Shodex ® ODP2 HP Columns<br />

High-Efficiency Polymer-Based<br />

Reversed-Phase Column<br />

• Column efficiency is comparable with that of silica-based<br />

ODS columns<br />

• Better retention of highly polar substances comparing to<br />

ODS columns<br />

• Long column life even with high protein content samples:<br />

ODP2 HP prevent protein adsorption that causes ODS<br />

column degradation<br />

• Excellent peak shape using low salt mobile phase, ideal<br />

for microbore<br />

• High pH stability<br />

ODP2 HP series is a polymer-based<br />

[poly(hydroxymethacrylate)] column for reversed-phase<br />

chromatography. The efficiency of ODP2 HP is improved<br />

over most resin-based columns, with typical theoretical plate<br />

number >65,000 per meter.<br />

ODP2 HP Columns<br />

Packing Format i.d. x Length Part No.<br />

ODP2 HP-4B, 5µm Analytical 4.6 x 50mm F7622001<br />

ODP2 HP-4D, 5µm Analytical 4.6 x 150mm F7622002<br />

ODP2 HP-4E, 5µm Analytical 4.6 x 250mm F7622003<br />

ODP2 HPG-4A, 5µm Analytical 4.6 x 10mm F6714010<br />

ODP2 HP-2B, 5µm Analytical 4.6 x 50mm F7622004<br />

ODP2 HP-2D, 5µm Analytical 4.6 x 150mm F7622005<br />

ODP2 HPG-2A, 5µm Analytical 4.6 x 10mm F6714011<br />

ODP2 HP Columns Specifications<br />

Packing<br />

Theoretical Plate Number<br />

(per column)<br />

Theoretical Plate Number<br />

(per meter) Particle Size pH Range i.d. x Length<br />

ODP2 HP-4B ≥3500 70,000 5µm 3–12 4.6 x 50mm<br />

ODP2 HP-4D ≥13,000 86,000 5µm 3–12 4.6 x 150mm<br />

ODP2 HP-4E ≥17,000 68,000 5µm 3–12 4.6 x 250mm<br />

ODP2 HPG-4A guard column guard column 5µm 3–12 4.6 x 10mm<br />

ODP2 HP-2B ≥3000 60,000 5µm 3–12 2.0 x 50mm<br />

ODP2 HP-2D ≥7000 46,600 5µm 3–12 2.0 x 150mm<br />

ODP2 HPG-2A guard column guard column 5µm 3–12 2.0 x 10mm<br />

hplc columns | large molecule<br />

Drug in Biological Fluid<br />

Microbore is effective for the high sensitivity analysis of drugs; however, when protein is present and enters the MS (Mass<br />

detector), it contaminates the MS or suppresses ionization of the sample. Often pretreatment does not remove protein<br />

thoroughly. Drugs in biological fluid are hard to analyze because protein co-elutes with the component of interest. The target<br />

drug receives ion suppression from the protein and appears as a small peak.<br />

ODP2 HP can separate the target drug from protein by eluting protein early. The result of barbital analysis with BSA using<br />

microbore is shown as below. Barbital was introduced into the MS by a switching valve after BSA was eluted, and barbital<br />

was detected without any influence of ion suppression.<br />

1,800K<br />

1,600K<br />

1,400K<br />

1,200K<br />

1,000K<br />

800K<br />

600K<br />

400K<br />

200K<br />

130K<br />

120K<br />

110K<br />

100K<br />

90K<br />

80K<br />

70K<br />

60K<br />

50K<br />

40K<br />

30K<br />

20K<br />

10K<br />

0<br />

Valve Switch<br />

1<br />

Barbital<br />

130K<br />

120K<br />

110K<br />

100K<br />

90K<br />

80K<br />

70K<br />

60K<br />

50K<br />

40K<br />

30K<br />

20K<br />

10K<br />

0<br />

Valve Switch<br />

1<br />

Barbital<br />

1,800K BSA<br />

1,600K<br />

1,400K<br />

MS<br />

1,200K<br />

1,000K<br />

800K<br />

600K<br />

400K<br />

1<br />

200K<br />

1<br />

0<br />

UV<br />

0 UV<br />

0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Min. 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Min.<br />

MS<br />

more info<br />

For other Shodex ® columns, including KW400, KF-400, SB-800,<br />

KF-400, KF-600, KF-800, NH2P, Ion Exchange, affinity, and sugar<br />

columns, visit www.discoverysciences.com.<br />

www.discoverysciences.com 81


analytical hplc<br />

hplc columns | small molecule<br />

Waters ® Spherisorb ® Columns<br />

All Waters ® columns are packed by <strong>Grace</strong> to our highest QC<br />

standards. Spherisorb ® columns have 80Å pores and 220m 2 /g<br />

surface area. ODS-1 is unendcapped with a 6% carbon load,<br />

and ODS-2 is endcapped with a 12% carbon load.<br />

Spherisorb ® HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

Waters ® Fittings<br />

Part No.<br />

ODS-1, 5µm Analytical 4.6 x 150mm 8441 8443<br />

Analytical 4.6 x 250mm 8364 8357<br />

ODS-2, 3µm Analytical 4.6 x 100mm 8487 8489<br />

Analytical 4.6 x 150mm 8558 8560<br />

ODS-2, 5µm Analytical 4.6 x 150mm 8545 8547<br />

Analytical 4.6 x 250mm 8736 8738<br />

C8, 3µm Analytical 4.6 x 100mm 8561 8563<br />

Analytical 4.6 x 150mm 8609 8611<br />

C8, 5µm Analytical 4.6 x 150mm 8571 8573<br />

Analytical 4.6 x 250mm 8744 8746<br />

C6, 5µm Analytical 4.6 x 150mm 8211 8217<br />

Analytical 4.6 x 250mm 8223 8224<br />

Phenyl, 5µm Analytical 4.6 x 150mm 8689 8691<br />

Analytical 4.6 x 250mm 8752 8754<br />

Cyano, 5µm Analytical 4.6 x 150mm 8713 8715<br />

Analytical 4.6 x 250mm 8361 8362<br />

Amino, 5µm Analytical 4.6 x 150mm 8739 8741<br />

Analytical 4.6 x 250mm 8371 8372<br />

Silica, 3µm Analytical 4.6 x 100mm 8382 8383<br />

Analytical 4.6 x 150mm 8554 8556<br />

Silica, 5µm Analytical 4.6 x 150mm 8389 8391<br />

Analytical 4.6 x 250mm 8376 8377<br />

SAX, 5µm Analytical 4.6 x 250mm 8765 8767<br />

SCX, 5µm Analytical 4.6 x 250mm 8888 8889<br />

Spherisorb ® All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

ODS-1, 5µm 4.6 x 7.5mm 3 96218<br />

ODS-2, 5µm 4.6 x 7.5mm 3 96219<br />

C8, 5µm 4.6 x 7.5mm 3 96220<br />

C6, 5µm 4.6 x 7.5mm 3 96221<br />

Phenyl, 5µm 4.6 x 7.5mm 3 96226<br />

Cyano, 5µm 4.6 x 7.5mm 3 96225<br />

Amino, 5µm 4.6 x 7.5mm 3 96224<br />

Silica, 5µm 4.6 x 7.5mm 3 96227<br />

SAX, 5µm 4.6 x 7.5mm 3 96228<br />

SCX, 5µm 4.6 x 7.5mm 3 96217<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

more info<br />

If you like Spherisorb ® , try <strong>Grace</strong>’s lower cost Allsphere on<br />

page 59.<br />

Beckman ® Ultrasphere ®<br />

Columns<br />

• Low metal content for symmetrical peaks<br />

• Narrow particle size range for high efficiency<br />

• Maximum surface coverage for long column lifetimes<br />

All Ultrasphere ® columns are packed by <strong>Grace</strong> to our highest<br />

QC standards. Ultrasphere ® columns are highly endcapped<br />

to reduce silanol interactions and have a narrow particle size<br />

range for excellent resolving power.<br />

1<br />

Tricyclic Antidepressants<br />

2 3 4 5<br />

6<br />

7<br />

0 5 10 15 Min.<br />

7739<br />

1. Doxepin<br />

2. Desipramine<br />

3. Nortriptyline<br />

4. Imipramine<br />

5. Amitriptyline<br />

6. Trimipramine<br />

7. Clomipramine<br />

Column: Ultrasphere ® C18, 5µm, 4.6 x 150mm<br />

(Part No. 235330)<br />

Mobile Phase: 10mM Triethylamine, pH2.5:Acetonitrile (71:29)<br />

Flow Rate: 2.0mL/min<br />

Detector: UV at 216nm<br />

Ultrasphere ® HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 3µm Analytical 4.6 x 75mm 244254<br />

C18, 5µm Microbore 2.0 x 150mm 237390<br />

Microbore 2.0 x 250mm 244434<br />

Analytical 4.6 x 150mm 235330<br />

Analytical 4.6 x 250mm 235329<br />

Prep 10 x 250mm 235328<br />

C18-IP, 5µm Analytical 4.6 x 150mm 235334<br />

Analytical 4.6 x 250mm 235335<br />

C8, 5µm Analytical 4.6 x 150mm 235333<br />

Analytical 4.6 x 250mm 235332<br />

Cyano, 5µm Analytical 4.6 x 150mm 244070<br />

Analytical 4.6 x 250mm 244071<br />

Silica, 5µm Analytical 4.6 x 150mm 235342<br />

Analytical 4.6 x 250mm 235341<br />

Ultrasphere ® Guard Columns<br />

Description i.d. x Length Qty. Part No.<br />

C18, 5µm 4.6 x 45mm ea 243536<br />

C18-IP, 5µm 4.6 x 45mm ea 243534<br />

C8, 5µm 4.6 x 45mm ea 243532<br />

Cyano, 5µm 4.6 x 45mm ea 243538<br />

Silica, 5µm 4.6 x 45mm ea 243530<br />

Ultrasphere ® guard columns connect directly to the analytical column with a<br />

zero dead volume connector, or a small piece of tubing with finger tight fittings.<br />

No holder required.<br />

82<br />

www.discoverysciences.com


analytical hplc<br />

ZirChrom ® Columns<br />

• Better pH and thermal stability than silica-based columns<br />

• More efficient than polymer-based columns<br />

• Widest range of reversed-phase selectivities<br />

ZirChrom Separations, Inc. produces HPLC columns based<br />

on 3µm zirconia (zirconium oxide) particles. These columns<br />

are more rugged and durable than silica-based columns<br />

and more efficient than polymer-based columns. ZirChrom ®<br />

normal-phase and reversed-phase columns can be used<br />

across the entire pH range (1–14) and are thermally stable to<br />

200°C. Additionally, zirconia’s silanol-free surface produces<br />

sharp, symmetrical peaks for amines without mobile phase<br />

modifiers.<br />

ZirChrom ® Packings<br />

Packing Functional Group Mode<br />

DiamondBond-C18 Octadecylsilane Reversed-Phase<br />

PBD Polybutadiene Reversed-Phase &<br />

Secondary Ionic<br />

PS Polystyrene Reversed-Phase<br />

(Low Retention)<br />

CARB Graphitic Carbon Reversed-Phase<br />

(High Retention)<br />

PHASE Zirconia Normal-Phase<br />

EZ — Reversed-Phase<br />

MS — Reversed-Phase<br />

• DiamondBond ® -C18 — ideal for microbore applications<br />

and acidic compounds. pH range 1–14<br />

• ZirChrom ® -PBD — for general purpose applications and<br />

basic compounds; similar to ODS for non-electrolytes.<br />

pH range 1–14<br />

• ZirChrom ® -PS — ideal for highly aqueous mobile phases;<br />

an alternative to ODS selectivity. pH range 1–14<br />

• ZirChrom ® -CARB — for diastereomers/geometric<br />

isomers; greatest difference in selectivity compared<br />

to ODS. pH range 1–14<br />

• ZirChrom ® -Phase — the bare zirconia particle. The<br />

columns are used as a normal-phase alternative to silica.<br />

pH range 1–14<br />

• ZirChrom ® -EZ — unique selectivity with mobile phase<br />

selectivity. pH range 1–10<br />

• ZirChrom ® -MS — low column bleed makes it ideal for<br />

microbore applications. pH range 1–10<br />

ZirChrom ® Specifications<br />

Pore Size<br />

300Å<br />

Particle Size 3µm, 5µm<br />

Surface Area 30m 2 /g<br />

pH Range 1–14 (EZ and MS 1–10)<br />

Max. Temperature 200°C<br />

EZ and MS HPLC Columns<br />

• Unique selectivity on a zirconia platform<br />

• Mobile phase flexibility, including microbore<br />

compatible buffers<br />

• Stable from pH 1–10<br />

The deactivation of Lewis acid sites on the zirconia surface<br />

allows for the chromatography of Lewis base analytes using<br />

volatile mobile phase additives, including conventional<br />

microbore compatible buffers such as acetate and formate.<br />

ZirChrom ® HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

DiamondBond ® , 3µm Microbore 2.1 x 100mm DB01-1021<br />

Microbore 2.1 x 150mm DB01-1521<br />

Analytical 4.6 x 50mm DB01-0546<br />

Analytical 4.6 x 100mm DB01-1046<br />

Analytical 4.6 x 150mm DB01-1546<br />

PBD, 3µm Microbore 2.1 x 100mm ZR03-1021<br />

Microbore 2.1 x 150mm ZR03-1521<br />

Analytical 4.6 x 50mm ZR03-0546<br />

Analytical 4.6 x 100mm ZR03-1046<br />

Analytical 4.6 x 150mm ZR03-1546<br />

PS, 3µm Microbore 2.1 x 100mm ZR09-1021<br />

Microbore 2.1 x 150mm ZR09-1521<br />

Analytical 4.6 x 50mm ZR09-0546<br />

Analytical 4.6 x 100mm ZR09-1046<br />

Analytical 4.6 x 150mm ZR09-1546<br />

CARB, 3µm Microbore 2.1 x 100mm ZR01-1021<br />

Microbore 2.1 x 150mm ZR01-1521<br />

Analytical 4.6 x 100mm ZR01-1046<br />

Analytical 4.6 x 150mm ZR01-1546<br />

PHASE, 3µm Microbore 2.1 x 100mm ZR02-1021<br />

Microbore 2.1 x 150mm ZR02-1521<br />

Analytical 4.6 x 100mm ZR02-1046<br />

Analytical 4.6 x 150mm ZR02-1546<br />

EZ, 3µm Microbore 2.1 x 50mm EZ01-0521<br />

Microbore 2.1 x 100mm EZ01-1021<br />

Microbore 2.1 x 150mm EZ01-1521<br />

Microbore 2.1 x 250mm EZ01-2521<br />

Analytical 4.6 x 50mm EZ01-0546<br />

Analytical 4.6 x 100mm EZ01-1046<br />

Analytical 4.6 x 150mm EZ01-1546<br />

Analytical 4.6 x 250mm EZ01-2546<br />

EZ, 5µm Microbore 2.1 x 50mm EZ01-05215<br />

Microbore 2.1 x 100mm EZ01-10215<br />

Microbore 2.1 x 150mm EZ01-15215<br />

Microbore 2.1 x 250mm EZ01-25215<br />

Analytical 4.6 x 50mm EZ01-05465<br />

Analytical 4.6 x 100mm EZ01-10465<br />

Analytical 4.6 x 150mm EZ01-15465<br />

Analytical 4.6 x 250mm EZ01-25465<br />

MS, 3µm Microbore 2.1 x 50mm MS01-0521<br />

Microbore 2.1 x 100mm MS01-1021<br />

Microbore 2.1 x 150mm MS01-1521<br />

Microbore 2.1 x 250mm MS01-2521<br />

Analytical 4.6 x 50mm MS01-0546<br />

Analytical 4.6 x 100mm MS01-1046<br />

Analytical 4.6 x 150mm MS01-1546<br />

Analytical 4.6 x 250mm MS01-2546<br />

MS, 5µm Microbore 2.1 x 50mm MS01-05215<br />

Microbore 2.1 x 100mm MS01-10215<br />

Microbore 2.1 x 150mm MS01-15215<br />

Microbore 2.1 x 250mm MS01-25215<br />

Analytical 4.6 x 50mm MS01-05465<br />

Analytical 4.6 x 100mm MS01-10465<br />

Analytical 4.6 x 150mm MS01-15465<br />

Analytical 4.6 x 250mm MS01-25465<br />

hplc columns | small molecule<br />

www.discoverysciences.com 83


analytical hplc<br />

Vydac ® Large Molecule Columns<br />

Vydac ® has always been a trusted name in bioseparations, now, with technology acquired by <strong>Grace</strong> over the past few years,<br />

we have expanded this expertise further. New <strong>Grace</strong> ® large molecule columns range from nano, capillary to micro, analytical<br />

to preparative columns.<br />

hplc columns | large molecule<br />

Separate biomolecules from small peptides to large intact proteins with the Vydac ® family of products which includes reversedphase,<br />

normal-phase, ion-exchange, and affinity phases. Our extensive applications library offers solid method development<br />

guidance, and our technical experts provide insight to even the most unusual separation challenges. Whether your primary<br />

analysis consideration is speed, MS compatibility, resolution, or recovery, we have a solution.<br />

Column Selection for Polypeptides<br />

The reversed-phase column for a polypeptide separation should be selected based on the hydrophobicity of the polypeptide<br />

being chromatographed and molecular weight as a secondary consideration.<br />

Molecular Weight<br />

1000<br />

Increasing hydrophilicity<br />

10,000<br />

C 18<br />

=<br />

<strong>Grace</strong>Alpha<br />

C 18<br />

= 218TP, 238TP, 218MS<br />

C 8<br />

= 208TP, 208MS<br />

C 4<br />

= 214TP, 214MS<br />

Increasing hydrophobicity<br />

100,000<br />

Diphenyl = 219TP<br />

Phase<br />

Simple Enzymatic<br />

Digests<br />

(12 proteins)<br />

Biomolecules<br />

0-5K MW<br />

Biomolecules<br />

5-10K MW<br />

Biomolecules<br />

>10K MW<br />

Un-denatured,<br />

Intact Proteins<br />

Antibodies<br />

Oligonucleotides<br />

Oligosaccharides<br />

Comments<br />

218MS (C18)<br />

See page 85–87<br />

Polymeric bonding highest hydrophic<br />

interaction and unique geometric selectivity<br />

238MS (C18)<br />

See page 85–87<br />

Monomeric bonding offers increased peptide<br />

interaction and generally yields higher peak<br />

counts. Different selectivity compared to<br />

218MS.<br />

208MS (C8<br />

See page 85–87<br />

Lower hydrophobicity is better for larger<br />

molecules<br />

214MS (C4)<br />

See page 85–87<br />

Ideal for hydrophobic proteins, or when<br />

minimal organic is desired<br />

219MS (Diphenyl)<br />

See page 85–87<br />

Lowest capacity, highly selective for proteins<br />

with aromatic sidechains<br />

Everest ® C18<br />

See page 88–89<br />

Maximum surface coverage for highest<br />

resolution of complex samples<br />

ProZap<br />

See page 93–94<br />

Sub 2µm, in Expedite format optimized for<br />

fast analysis<br />

218TP (C18)<br />

See page 90–92<br />

First generation media with extensive<br />

applications library<br />

214TP (C4)<br />

See page 90–92<br />

First generation media with extensive<br />

applications library<br />

related products<br />

Looking for large molecule prep columns?<br />

See pages 156–161.<br />

84<br />

www.discoverysciences.com


analytical hplc<br />

Vydac ® MS Introduction<br />

New Generation Columns with Unsurpassed Resolution, Sensitivity,<br />

and Recovery<br />

• Unique selectivity reveals peaks otherwise masked by other C18 columns<br />

• Excellent peak shape with little or no TFA<br />

• High protein recoveries make scale-up easy<br />

Vydac ® MS columns are the latest development in the ongoing effort to provide the best reversedphase<br />

HPLC columns for biomolecule. A surface treatment and propriatary bonding process gives<br />

Vydac ® MS columns a unique selective not found anywhere else. A variety of reversed phases makes<br />

this product line suitable for small peptides to large intact, undenatured proteins.<br />

MS Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

208MS C8 Silica Spheroidal 5µm 300Å 70m 2 /g 5% Polymeric Yes L7<br />

214MS C4 Silica Spheroidal 5µm 300Å 70–110m 2 /g 3% Polymeric Yes L26<br />

218MS C18 Silica Spheroidal 3, 5, 10, 10–15µm 300Å 60–110m 2 /g 8% Polymeric Yes L1<br />

238MS C18 Silica Spheroidal 5µm 300Å 70m 2 /g 4% Monomeric Yes L1<br />

219MS Di-Phe Silica Spheroidal 5µm 300Å 70m 2 /g 4% Polymeric Yes —<br />

Unique Selectivity<br />

A sample of bovine fetuin, a 36kD glycoprotein, was digested<br />

with trypsin. Some of the sample components interfere with<br />

the peptide separation on the Competitor 1 and Competitor 2<br />

columns and appear as a chromatographic “hump” with peaks<br />

riding on top. The unique selectivity of Vydac ® MS columns<br />

solves these separation problems<br />

1<br />

2 4<br />

4<br />

1<br />

4<br />

3<br />

2<br />

4<br />

1 3<br />

4<br />

2<br />

1<br />

3<br />

2<br />

1 2<br />

10 20 30 40 50 60 65 Min.<br />

1. 18.8 kD Protein<br />

2. Non-myristoylated p14<br />

3. Myristoylated p14<br />

4. Triton ® X (Surfactant)<br />

Vydac ® MS C4 Column<br />

Competitor 1 C4 Column<br />

Competitor 2 C3 Column<br />

Competitor 3 C4 Column<br />

Competitor 4 C4 Column<br />

Columns: Vydac ® MS C4 214MS54, Competitor 1 C4,<br />

Competitor 2 C3, Competitor 3 C4, and<br />

Competitor 4 C4 (all 300Å, 5µm, except 4µm for<br />

Competitor 1, 4.6 x 250mm)<br />

Flow Rate:<br />

Mobile Phase:<br />

Transmembrane Protein p14 Columns<br />

1.0mL/min<br />

A: 0.1% v/v TFA in H2O<br />

B: 0.085% v/v TFA in Acetonitrile<br />

Gradient Vydac ® , Comp. 1, and Comp. 2:<br />

Time: 0 20 25 45<br />

%B: 20 60 80 80<br />

Gradient Comp. 3 and Comp. 4:<br />

Time: 0 20 25 45 50 80<br />

%B: 20 60 80 80 90 90<br />

Detector: UV at 215nm<br />

Column Temp: Ambient, 25°C<br />

Injection Vol: 50µL<br />

Unsurpassed Resolution and Peak Symmetry<br />

Vydac ® MS C4 columns provide the overall best performance<br />

for hGH and desamido hGH analysis. Competitive columns<br />

show significant, undesirable interaction of hGH with the<br />

stationary phase.<br />

Human Growth Hormone (hGH) Assay Columns<br />

1. Desamido HGH<br />

2. HGH<br />

2<br />

2<br />

1 2<br />

Vydac ® MS C4 Column<br />

1<br />

Competitor 1 C4 Column<br />

1<br />

Competitor 2 C4 Column<br />

1 2<br />

Competitor 3 C3 Column<br />

0 20 40 60 Min.<br />

Columns: All 300Å, 5µm, 4.6 x 250mm<br />

Mobile Phase: Isocratic, 71% 50mM Tris, pH 7.5, 29% n-propanol<br />

Flow Rate: 0.5mL/min<br />

Detector: UV at 220nm<br />

Column Temp: 45°C<br />

Injection Vol: 20µL of a 1mg/mL preparation<br />

more info<br />

For additional protein and peptide applications, see application<br />

section pages 429–441.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

7300<br />

hplc columns | large molecule<br />

Reptilian reovirus RRV p14 sample courtesy of Drs. Roberto J. de Antueno and Roy<br />

Duncan, Dalhousie University, Halifax, Nova Scotia.<br />

www.discoverysciences.com 85


analytical hplc<br />

hplc columns | large molecule<br />

Vydac ® MS Columns<br />

Excellent Peak Shape with Little or No TFA<br />

It is common practice for protein and peptide separations to<br />

include an acidic modifier such as TFA in the mobile phase.<br />

TFA masks basic entities, reducing mixed-mode retention,<br />

and improving peak symmetry. TFA also changes retention<br />

and selectivity for different analytes, and its concentration<br />

can be adjusted to optimize a separation. Unfortunately<br />

TFA is UV absorbent and contributes background at low<br />

UV wavelengths. Also It is especially problematic with<br />

electrospray MS where it interferes with ion generation,<br />

called “quenching”, and reduces MS sensitivity.<br />

0.6 AU<br />

0.4<br />

0.2<br />

0<br />

0<br />

Columns:<br />

0.1% TFA<br />

Flow Rate:<br />

Mobile Phase:<br />

Gradient:<br />

Detector:<br />

Peptides on 218MS C18 Reversed-Phase<br />

0.05% TFA<br />

0.02% TFA<br />

0.01% TFA<br />

1<br />

1<br />

1<br />

1<br />

3<br />

2<br />

2<br />

2<br />

3<br />

2<br />

4<br />

3<br />

1. Neurotensin 1-8 (fragment)<br />

2. Oxytocin<br />

3. Angiotensin II<br />

4. Neurotensin<br />

4<br />

10 20 30 Min.<br />

Vydac ® C18, 5µm, 4.6 x 250mm<br />

(Part No. 218MS54)<br />

1.5mL/min<br />

A: 5% Acetonitrile in Water with TFA as indicated (v/v)<br />

B: 95% Acetonitrile in Water with TFA as in A<br />

Linear from 0 to 20% B over 20min, then to<br />

100% B in 5min<br />

UV at 220nm<br />

3<br />

4<br />

4<br />

Hydrophobic Proteins<br />

Transmembrane proteins are hydrophobic proteins<br />

which bind to cell membranes and are particularly difficult to<br />

separate. Vydac ® MS columns provide excellent selectivity<br />

and peak shape for these molecules. In this case, a<br />

hydrophobic transmembrane protein was separated from<br />

a synthetic myristoylated derivative and other cellular<br />

components.<br />

Tryptic Digest of Fetuin on<br />

300Å C18 Columns<br />

Vydac ® MS C18<br />

Column<br />

Competitor 1 C18<br />

Column<br />

Competitor 2 C18<br />

Column<br />

0 20 40 60 80 Min.<br />

Columns: Vydac ® MS C18 238MS5415, Competitor 1 C18, and<br />

Competitor 2 C18 (all 300Å, 5µm, 4.6 x 150mm)<br />

Flow Rate: 1.0mL/min<br />

Mobile Phase: A: 0.1% v/v TFA in H2O<br />

B: 0.085% v/v TFA acid in Acetonitrile<br />

Gradient: Time: 0 5 80 90 100<br />

%B: 4 4 40 90 90<br />

Detector: UV at 215nm<br />

Column Temp: Ambient, 22°C<br />

Injection Vol: 3µL of a 6 µg/µL digest (180 µg total peptide load)<br />

The Vydac ® column provides better separation and recovery for a<br />

highly hydrophobic membrane protein (RRV p14) and its fatty acid<br />

modified (myristolyated) form, a component of a potentially new<br />

vaccine delivery system.<br />

High Protein Recovery for Higher Sensitive,<br />

Ideal for Preparative Chromatography<br />

Surface chemistry reduces adsorption of proteins for higher<br />

recoveries and also increases mass loading.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

% Recovery at Low Protein Load: Vydac ® MS C4 vs.<br />

2 Competitors<br />

100<br />

80<br />

Loading Amount:<br />

1µg of Cytochrome C<br />

% Recovery<br />

60<br />

40<br />

20<br />

Vydac ® MS<br />

Competitor 1<br />

Competitor 2<br />

0<br />

Vydac ® MS C4 column provides more than 20% more loading of<br />

Cytochrome C.<br />

86<br />

www.discoverysciences.com


analytical hplc<br />

Vydac ® MS Columns<br />

Vydac ® MS Analytical Columns<br />

Columns<br />

Recommended Guards<br />

Particle Size i.d. 50mm 100mm 150mm 250mm Guard Kit 1 Guard Cartridge 2<br />

214 MS C4<br />

5µm 1.0mm 214MS5105 214MS5110 214MS5115 214MS51 214GK51MS 214GD51MS<br />

2.1mm 214MS5205 214MS5210 214MS5215 214MS52 214GK52MS 214GD52MS<br />

3.2mm — — — 214MS53 214GK54MS 214GD54MS<br />

4.6mm 214MS5405 214MS5410 214MS5415 214MS54 214GK54MS 214GD54MS<br />

208 MS C8<br />

5µm 1.0mm 208MS5105 208MS5110 208MS5115 208MS51 208GK51MS 208GD51MS<br />

2.1mm 208MS5205 208MS5210 208MS5215 208MS52 208GK52MS 208GD52MS<br />

3.2mm — — — 208MS53 208GK54MS 208GD54MS<br />

4.6 mm 208MS5405 208MS5410 208MS5415 208MS54 208GK54MS 208GD54MS<br />

218 MS Polymeric C18<br />

5µm 1.0mm 218MS5105 218MS5110 218MS5115 218MS51 218GK51MS 218GD51MS<br />

2.1mm 218MS5205 218MS5210 218MS5215 218MS52 218GK52MS 218GD52MS<br />

3.2mm — — — 218MS53 218GK54MS 218GD54MS<br />

4.6mm 218MS5405 218MS5410 218MS5415 218MS54 218GK54MS 218GD54MS<br />

238 MS Monomeric C18<br />

5µm 1.0mm 238MS5105 238MS5110 238MS5115 238MS51 238GK51MS 238GD51MS<br />

2.1mm 238MS5205 238MS5210 238MS5215 238MS52 238GK52MS 238GD52MS<br />

3.2mm — — — 238MS53 238GK54MS 238GD54MS<br />

4.6mm 238MS5405 238MS5410 238MS5415 238MS54 238GK54MS 238GD54MS<br />

219 MS Diphenyl<br />

5µm 1.0mm 219MS5105 219MS5110 219MS5115 219MS51 219GK51MS 219GD51MS<br />

2.1mm 219MS5205 219MS5210 219MS5215 219MS52 219GK52MS 219GD52MS<br />

3.2mm — — — 219MS53 219GK54MS 219GD54MS<br />

4.6mm 219MS5405 219MS5410 219MS5415 219MS54 219GK54MS 219GD54MS<br />

1<br />

A guard kit includes a holder and one guard cartridge; 2 Guard cartirdge units include two guard cartridges.<br />

hplc columns | large molecule<br />

Vydac ® MS Nano and Capillary Columns<br />

i.d. 50mm 100mm 150mm 250mm<br />

214 MS C4<br />

5µm 75µm 214MS5.07505 214MS5.07510 214MS5.07515 214MS5.07525<br />

150µm 214MS5.1505 214MS5.1510 214MS5.1515 214MS5.1525<br />

300µm 214MS5.305 214MS5.310 214MS5.315 214MS5.325<br />

500µm 214MS5.505 214MS5.510 214MS5.515 214MS5.525<br />

208 MS C8<br />

5µm 75µm 208MS5.07505 208MS5.07510 208MS5.07515 208MS5.07525<br />

150µm 208MS5.1505 208MS5.1510 208MS5.1515 208MS5.1525<br />

300µm 208MS5.305 208MS5.310 208MS5.315 208MS5.325<br />

500µm 208MS5.505 208MS5.510 208MS5.515 208MS5.525<br />

218 MS Polymeric C18<br />

3µm 75µm 218MS3.07505 218MS3.07510 218MS3.07515 218MS3.07525<br />

150µm 218MS3.1505 218MS3.1510 218MS3.1515 218MS3.1525<br />

300µm 218MS3.305 218MS3.310 218MS3.315 218MS3.325<br />

500µm 218MS3.505 218MS3.510 218MS3.515 218MS3.525<br />

5µm 75µm 218MS5.07505 218MS5.07510 218MS5.07515 218MS5.07525<br />

150µm 218MS5.1505 218MS5.1510 218MS5.1515 218MS5.1525<br />

300µm 218MS5.305 218MS5.310 218MS5.315 218MS5.325<br />

500µm 218MS5.505 218MS5.510 218MS5.515 218MS5.525<br />

238 MS Monomeric C18<br />

5µm 75µm 238MS5.07505 238MS5.07510 238MS5.07515 238MS5.07525<br />

150µm 238MS5.1505 238MS5.1510 238MS5.1515 238MS5.1525<br />

300µm 238MS5.305 238MS5.310 238MS5.315 238MS5.325<br />

500µm 238MS5.505 238MS5.510 238MS5.515 238MS5.525<br />

219 MS Diphenyl<br />

5µm 75µm 219MS5.07505 219MS5.07510 219MS5.07515 219MS5.07525<br />

150µm 219MS5.1505 219MS5.1510 219MS5.1515 219MS5.1525<br />

300µm 219MS5.305 219MS5.310 219MS5.315 219MS5.325<br />

500µm 219MS5.505 219MS5.510 219MS5.515 219MS5.525<br />

Vydac ® MS Guard Cartridges<br />

Packing i.d. x Length Qty. Part No.<br />

C18 Polymeric, 5µm*<br />

Capillary Guard**<br />

0.150 x 10mm ea 218MS5C0115<br />

0.300 x 10mm ea 218MS5C0130<br />

1.0 x 10mm 2 218GD51MS<br />

C4, 5µm* Capillary Guard** 0.150 x 10mm ea 214MS5C0115<br />

0.300 x 10mm ea 214MS5C0130<br />

1.0 x 10mm 2 214GD51MS<br />

*All-Guard holder required. Other particle sizes available.<br />

**1.5µm and 5µm particles and other dimensions are available.<br />

Vydac ® MS Guard Cartridges (continued)<br />

Packing Qty. Part No.<br />

Capillary Guard Cartridge Holder<br />

Guard Holder for 0.100mm and 0.150mm Guards ea GR-3710E<br />

Guard Holder for 0.300mm and 0.500mm Guards ea GR-3710A<br />

Guard Holder for 1mm Guards ea GCH1<br />

www.discoverysciences.com 87


analytical hplc<br />

hplc columns | large molecule<br />

Vydac ® Everest ® Columns Introduction<br />

High Resolution for Complex Peptide Samples<br />

• High resolution of complex peptide digests<br />

• Unique selectivity for both hydrophilic and hydrophobic peptides<br />

• Exceptional microbore sensitivity with little or no TFA in the mobile phase<br />

Everest ® columns provide exceptionally high resolution for complex peptide digest separations.<br />

Unique selectivity and sensitivity are the result of new bonding technology that improves C18<br />

surface coverage and deactivates residual silanols. Previously, the best 300Å C18 chemistries have<br />

had carbon coverage in the 2.8 to 3.6µmol/m 2 range. Everest ® C18 coverage is in excess of 4µmol/m 2<br />

and approximates the theoretical limit based on surface area. This increased shielding of the base silica<br />

increases column life and reduces the amount of TFA required to shield the silica.<br />

Everest ® Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

238EV C18 Silica Spheroidal 5, 10, 10–15, 15–20µm 300Å 70–110m 2 /g 6% Monomeric Yes L1<br />

Tryptic Digest of Bovine Serum Albumin<br />

Everest ® Column<br />

110 peaks<br />

Commercial Column C<br />

94 peaks<br />

Commercial Column D<br />

96 peaks<br />

Intensity (x 10 6 cps)<br />

Base Peak Chromatogram of Tryptic Digest of BSA<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

7189<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Min.<br />

Column: Vydac ® Everest ® C18, 300Å, 5µm, 4.6 x 150mm<br />

Commercial 300å c18 columns 4.6 x 150mm<br />

(Part No. 238EV5415)<br />

Mobile Phase: A: 0.1% TFA in Water<br />

B: 0.085% TFA in Acetonitrile<br />

Gradient: Time: 0 5 80 90 100<br />

%B: 4 4 40 90 90<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 215nm<br />

Everest ® columns outperform competitor columns at higher peptide<br />

loads, by providing higher-resolution separations (average of 17%<br />

higher peak counts than competitor columns tested).<br />

0<br />

0 5 15 25 35 45 55 65 75 85 95 Min.<br />

Column: Vydac ® Everest ® C18, 300Å, 5µm, 300µm x 150mm;<br />

(Part No. 238EV5.315)<br />

Mobile phase: A: 0.1% v/v Formic Acid in Water<br />

B: 0.1% v/v Formic Acid in Acetonitrile<br />

Gradient: Time: 0 5 75 85 95<br />

%B: 4 4 40 90 90<br />

Flow Rate: 5µL/min<br />

Column Temp: 22°C<br />

Detector: MS + ESI<br />

The Everest ® column performs exceptionally well with no TFA in the<br />

mobile phase, ensuring excellent microbore sensitivity.<br />

Everest ® 300Å C18<br />

Columns<br />

Recommended Guards<br />

Particle Size i.d. 50mm 100mm 150mm 250mm Guard Kit 1 Guard Cartridge 2<br />

Everest ® Analytical Columns 238EV C18<br />

5µm 1.0mm 3 238EV5105 238EV5110 238EV5115 238EV51 238GK51EV 238GD51EV<br />

2.1mm 3 238EV5205 238EV5210 238EV5215 238EV52 238GK52EV 238GD52EV<br />

4.6mm 3 238EV5405 238EV5410 238EV5415 238EV54 238GK54EV 238GD54EV<br />

Everest ® Capillary Columns 238ZU C18<br />

5µm 75µm 238EV5.07505 238EV5.07510 238EV5.07515 238EV5.07525 — —<br />

150µm 238EV5.1505 238EV5.1510 238EV5.1515 238EV5.1525 — —<br />

300µm 238EV5.305 238EV5.310 238EV5.315 238EV5.325 — —<br />

500µm 238EV5.505 238EV5.510 238EV5.515 238EV5.525 — —<br />

1<br />

A guard kit includes a holder and one guard cartridge. 2 Guard cartirdge units include two guard cartridges. 3 Titamium frits are standard in column diameters 4.6mm and smaller.<br />

Everest ® Guard Cartridges<br />

Packing i.d. x Length Qty. Part No.<br />

C18, 5µm* Capillary Guard** 0.150 x 10mm ea 238EV5C0115<br />

0.300 x 10mm ea 238EV5C0130<br />

1.0 x 10mm 2 238GD51EV<br />

*All-Guard holder required. Other particle sizes available.<br />

**1.5µm and 5µm particles and other dimensions are available.<br />

Everest ® Guard Cartridges (continued)<br />

Packing Qty. Part No.<br />

Capillary Guard Cartridge Holder<br />

Guard Holder for 0.100mm and 0.150mm Guards ea GR-3710E<br />

Guard Holder for 0.300mm and 0.500mm Guards ea GR-3710A<br />

Guard Holder for 1mm Guards ea GCH1<br />

88<br />

www.discoverysciences.com


analytical hplc<br />

Vydac ® Everest ® Columns<br />

Tryptic Digest of Cytochrome C<br />

Columns:<br />

Flow Rate:<br />

Mobile Phase:<br />

Everest ® 238EV5415 and 4 competitor<br />

300Å reversed-phase columns, all C18,<br />

5µm, 4.6 x 150mm<br />

1.0 mL/min<br />

A: 0.1% v/v TFA in water<br />

B: 0.085% v/v TFA in ACN<br />

Gradient: Time: 0 75 85 95<br />

%B: 4 40 90 90<br />

hold 90% B for 10 min<br />

Detector:<br />

UV at 215nm<br />

Everest ® Column<br />

4 3<br />

Competitor Column B<br />

3<br />

3<br />

Competitor Column D<br />

3 1<br />

Competitor Column E<br />

3<br />

2<br />

Competitor Column F<br />

3 2<br />

Number of Well-Resolved<br />

Peptide in Highlighted Areas<br />

7<br />

6<br />

4<br />

5<br />

5<br />

hplc columns | large molecule<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 Min.<br />

For a tryptic digest of Cytochrome C, an Everest ® column offers unique selectivity which allows the best separation of a group of hydrophilic<br />

and hydrophobic peptides. To assess resolution, chromatograms of tryptic digests of several proteins on an Everest ® column and several other<br />

commercial 300Å C18 reversed-phase columns were compared. Peak counts were based on detection by automated chromatography software<br />

with parameters set identically for all columns. In the analyses of a tryptic digest of cytochrome c, specific regions of the chromatogram were<br />

examined for the number of peaks resolved. The Everest ® column demonstrated unique selectivity for both hydrophilic and hydrophobic peptides.<br />

Tryptic Digest of Fetuin (a Glycoprotein)<br />

Everest ® Column<br />

98 peaks<br />

Competitor Column A<br />

97 peaks<br />

Columns: Everest ® 238EV5415 and 4 competitor<br />

300Å reversed-phase columns, all C18,<br />

5µm, 4.6 x 150mm<br />

Flow Rate: 1.0 mL/min<br />

Mobile Phase: A: 0.1% v/v TFA in water<br />

B: 0.085% v/v TFA in ACN<br />

Gradient: Time: 0 5 80 90 100<br />

%B: 4 4 40 90 90<br />

Detector: UV at 215nm<br />

Competitor Column B<br />

90 peaks<br />

Competitor Column C<br />

95 peaks<br />

Competitor Column D<br />

89 peaks<br />

0 10 20 30 40 50 60 70 80 Min.<br />

A tryptic digest of fetuin injected at high load on an Everest ® column provided higher peak counts compared to four commercial columns. Peak<br />

numbers shown are the average of three separations on each column.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

www.discoverysciences.com 89


analytical hplc<br />

hplc columns | large molecule<br />

Vydac ® TP Columns<br />

Industry Standard for Polypeptide Separations<br />

• Referred in over 9000 patents, Vydac ® 300Å TP is the industry-standard, for peptide,<br />

protein, and large molecule separations<br />

• Polymeric bonded phases have exceptionally long column lifetime and negligible<br />

phase leaching<br />

• Extensive applications library based on over two decade’s experience<br />

Vydac ® TP reversed-phase material consists of aliphatic groups bonded to the surface of 300Å pore diameter silica. The large<br />

pores of the 300Å TP silica give polypeptide molecules complete access to the interior of the silica pores. The unique process by<br />

which we manufacture Vydac ® TP silica results in high-purity, synthetic silica with carefully controlled characteristics. Vydac ® TP<br />

silica is the standard that has defined large pore HPLC silica for polypeptide separations for nearly two decades.<br />

Vydac ® TP Columns<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

101TP Sil Silica Spheroidal 5, 10, 10–15, 15–20µm 300Å 70–110m 2 /g — unbonded — L3<br />

201TP C18 Silica Spheroidal 5, 7, 10, 10–15, 15–20µm 300Å 70–90m 2 /g 8% Polymeric No L1<br />

202TP C18 Silica Spheroidal 3, 5, 10µm 300Å 60–90m 2 /g 9% Polymeric No L1<br />

208TP C8 Silica Spheroidal 3, 5, 7, 10, 10–15, 15–20µm 300Å 60–110m 2 /g 5% Polymeric Yes L7<br />

214TP C4 Silica Spheroidal 3, 5, 7, 10, 10–15, 15–20µm 300Å 60–110m 2 /g 3% Polymeric Yes L26<br />

218TP C18 Silica Spheroidal 3, 5, 7, 10, 10–15, 15–20µm 300Å 60–110m 2 /g 8% Polymeric Yes L1<br />

219TP Di-Phe Silica Spheroidal 3, 5, 7, 10, 10–15, 15–20µm 300Å 60–110m 2 /g 4% Polymeric Yes —<br />

238TP C18 Silica Spheroidal 3, 5, 7, 10, 10–15, 15–20µm 300Å 60–110m 2 /g 4% Monomeric Yes L1<br />

Vydac ® 218TP C18 Columns<br />

Vydac ® 218TP is a polymerically bonded endcapped<br />

n-octadecyl reversed-phase based on 300Å TP silica.<br />

Applications<br />

Vydac ® 218TP reversed-phase columns are recommended for<br />

the separation of:<br />

• Small polypeptides less than 4000–5000 MW<br />

• Enzymatic digest fragments<br />

• Natural and synthetic peptides<br />

• Multi-ring compounds<br />

Specific examples include:<br />

• Tryptic digests<br />

• S. aureus V8 digests<br />

• Synthetic peptides<br />

• Natural peptides<br />

• Peptide studies<br />

Standard<br />

Human Apolipoproteins<br />

7<br />

4 6 5<br />

1 2 3<br />

0 5 10 15 20 25 30 35 Min.<br />

Column: Vydac ® 218TP54, C18, 5µm, 4.6 x 250mm<br />

Flow Rate: 1.2mL/min<br />

Column Temp: 50°C<br />

Mobile Phase: A: 25% ACN/0.1% TFA in Water<br />

B: 58% ACN/0.1% TFA in Water<br />

Gradient: 0–100% B in 33min<br />

8<br />

11<br />

10<br />

9<br />

7110<br />

1. apoC-IIIa<br />

2. apoC-IIIb<br />

3. apoC-IIa<br />

4. apoC-IIIc<br />

5. apoC-I<br />

6. apoC-IIb<br />

7. apoA-Ia<br />

8. apoA-Ib<br />

9. apoA-IIc<br />

10. apoA-IIa<br />

11. apoA-IIb<br />

The standard was<br />

human insulin<br />

Vydac ® 208TP C8 Reversed-Phase<br />

Vydac ® 208TP is a polymerically bonded endcapped n-octyl<br />

reversed-phase based on 300Å TP silica.<br />

Separation of a Tryptic Digest on 208TP54<br />

Reversed-Phase Column<br />

Applications<br />

Vydac ® 208TP reversed-phase columns are recommended for<br />

the separation of:<br />

• Polypeptides up to 10,000–20,000 MW<br />

• Enzymatic digest fragments<br />

• Natural and synthetic peptides<br />

0 10 20 30 40 50 60 Min.<br />

Column:<br />

Flow Rate:<br />

Gradient:<br />

Vydac ® 208TP54, C8, 5µm, 4.6 x 250mm<br />

1.0mL/min<br />

0–30% ACN with 0.1% aqueous TFA over 60min<br />

90<br />

www.discoverysciences.com


analytical hplc<br />

Vydac ® 214TP C4<br />

Vydac ® 214TP is a polymerically bonded endcapped<br />

n-butyl reversed-phase based on 300Å TP silica. 214ATP is<br />

a less extensively endcapped C4 that has been found more<br />

suitable for resolution of degradation products in analysis of<br />

biosynthetic human growth hormone.<br />

Applications<br />

• Glycoproteins<br />

• Hemoglobin variants<br />

• Histones<br />

• Human growth hormone<br />

• Insulin variants<br />

• Membrane proteins<br />

Vydac ® 219TP Diphenyl Reversed-Phase<br />

Vydac ® 219TP is a polymerically bonded endcapped diphenyl<br />

reversed-phase based on 300Å TP silica. It combines<br />

moderate retentivity with unique selectivity.<br />

Applications<br />

• Polypeptides with aromatic side chains<br />

• Large, hydrophobic proteins<br />

• Membrane-spanning peptides<br />

• Lipid peptides<br />

• Fusion proteins from inclusion bodies<br />

1<br />

0 5 10 15 20 25 Min.<br />

Column:<br />

Gradient:<br />

Insulin Variants<br />

2<br />

5 6<br />

4<br />

3<br />

7<br />

8<br />

Vydac ® C4, 5µm, 4.6 x 250mm (Part No. 214TP54)<br />

27–30% ACN with 0.1% TFA over 25min<br />

From J. Rivier and R. McClintock, J. Chrom. 268, 112-119 (1983).<br />

1. Chicken<br />

2. Bovine<br />

3. Ovine<br />

4. Rabbit<br />

5. Human<br />

6. Porcine<br />

7. Rat I<br />

8. Rat II<br />

Comparison of Polypeptide Separations on C18, C4,<br />

and Diphenyl Reversed-Phase Columns<br />

218TP<br />

(C18)<br />

214TP<br />

(C4)<br />

219TP<br />

(diphenyl)<br />

1<br />

1<br />

1<br />

2<br />

2<br />

2<br />

1. H<br />

2. TH6<br />

hplc columns | large molecule<br />

0 5 10 15 20 25 30 Min.<br />

Columns:<br />

Gradient:<br />

Sample:<br />

Vydac ® 218TP5415 (C18), 214TP5415 (C4) and<br />

219TP5415 (diphenyl), all 5µm, 4.6 x 150mm<br />

10–90% ACN with 0.1% TFA over 30min<br />

18-residue helical peptide (1) and six-helix template<br />

assembled synthetic protein (2)<br />

Vydac ® 238TP C18 Reversed-Phase<br />

Vydac ® 238TP is a monomerically bonded endcapped<br />

n-octadecyl reversed-phase based on 300Å TP silica.<br />

Applications<br />

Monomerically bonded C18 provides an alternative to<br />

218TP polymeric C18 with subtle differences in selectivity.<br />

The combination of these adsorbents can reveal analytes that<br />

may be hidden on a single C18 column.<br />

more info<br />

For more protein and peptide applications, see the application<br />

section pages 429–441.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

13,14<br />

218TP54<br />

polymeric C18 811,12<br />

9<br />

10 1516<br />

24<br />

1 356<br />

7<br />

238TP54<br />

monomeric C18<br />

4,5<br />

2<br />

1 6<br />

3<br />

Columns:<br />

Flow Rate:<br />

Gradient:<br />

Detector:<br />

Synthetic Peptides<br />

8 14<br />

911<br />

13 1516<br />

7 10 12<br />

0 5 10 15 20 25 30 Min.<br />

1. GY<br />

2. VYV<br />

3. Neurotensin fragment<br />

1-8 (pELYENKPR)<br />

4. Ac-RGGGGLGLGK-NH2<br />

5. RGAGGLGLGK-NH2<br />

6. Ac-RGAGGLGLGK-NH2<br />

7. Ac-RGVGGLGLGK-NH2<br />

8. Oxytocin (CYIQNCPLG-NH2)<br />

9. Met Enkephalin (YGGFM)<br />

10. Bradykinin (RPPGFSPFR)<br />

11. Ac-RGVVGLGLGK-NH2<br />

12. Neurotensin Fragment<br />

8-13 (RRPYIL)<br />

13. Angiotensin II (DRVYIHPF)<br />

14. Leu Enkephalin (YGGFL)<br />

15. Neurotensin<br />

(pELYENKPRRPYIL)<br />

16. Angiotensin I<br />

(DRVYIHPFHL)<br />

Vydac ® 218TP54 and 238TP54, both C18, 5µm,<br />

4.6 x 250mm<br />

1.0mL/min<br />

10–40% ACN with 0.1% TFA (w/v) over 30min<br />

UV at 220nm<br />

www.discoverysciences.com 91


analytical hplc<br />

hplc columns | large molecule<br />

Vydac ® TP Columns<br />

Vydac ® TP Analytical Columns<br />

Columns<br />

Recommended Guards<br />

Particle Size i.d. 50mm 100mm 150mm 250mm Guard Kit 1 Guard Cartridge 2<br />

218TP C18<br />

3µm 4.6mm 218TP3405 218TP3410 — — 218GK34 218GD34<br />

5µm 1.0mm 218TP5105 218TP5110 218TP5115 218TP51 218GK51 218GD51<br />

2.1mm 218TP5205 218TP5210 218TP5215 218TP52 218GK52 218GD52<br />

3.2mm 218TP5305 218TP5310 218TP5315 218TP53 218GK54 218GD54<br />

4.6mm 218TP5405 218TP5410 218TP5415 218TP54 218GK54 218GD54<br />

208TP C8<br />

3µm 4.6mm 208TP3405 208TP3410 — — 208GK34 208GD34<br />

5µm 1.0mm 208TP5105 208TP5110 208TP5115 208TP51 208GK51 208GD51<br />

2.1mm 208TP5205 208TP5210 208TP5215 208TP52 208GK52 208GD52<br />

3.2mm 208TP5305 208TP5310 208TP5315 208TP53 208GK54 208GD54<br />

4.6mm 208TP5405 208TP5410 208TP5415 208TP54 208GK54 208GD54<br />

214TP C4<br />

3µm 4.6mm 214TP3405 214TP3410 — — 214GK34 214GD34<br />

5µm 1.0mm 214TP5105 214TP5110 214TP5115 214TP51 214GK51 214GD51<br />

2.1mm 214TP5205 214TP5210 214TP5215 214TP52 214GK52 214GD52<br />

3.2mm 214TP5305 214TP5310 214TP5315 214TP53 214GK54 214GD54<br />

4.6mm 214TP5405 214TP5410 214TP5415 214TP54 214GK54 214GD54<br />

214ATP C4 Columns<br />

5µm 2.1mm — — — 214ATP52 — —<br />

4.6mm — — — 214ATP54 — —<br />

219TP Diphenyl<br />

3µm 4.6mm 219TP3405 219TP3410 — — 219GK34 219GD34<br />

5µm 1.0mm 219TP5105 219TP5110 219TP5115 219TP51 219GK51 219GD51<br />

2.1mm 219TP5205 219TP5210 219TP5215 219TP52 219GK52 219GD52<br />

3.2mm 219TP5305 219TP5310 219TP5315 219TP53 219GK54 219GD54<br />

4.6mm 219TP5405 219TP5410 219TP5415 219TP54 219GK54 219GD54<br />

238TP C18<br />

3µm 4.6mm 238TP3405 238TP3410 — — 238GK34 238GD34<br />

5µm 1.0mm 238TP5105 238TP5110 238TP5115 238TP51 238GK51 238GD51<br />

2.1mm 238TP5205 238TP5210 238TP5215 238TP52 238GK52 238GD52<br />

3.2mm 238TP5305 238TP5310 238TP5315 238TP53 238GK54 238GD54<br />

4.6mm 238TP5405 238TP5410 238TP5415 238TP54 238GK54 238GD54<br />

NOTE: Additional column diameters and lengths are available on request. Please contact <strong>Grace</strong> Davison Discovery Sciences to discuss your requirements.<br />

1<br />

A guard kit includes a holder and one guard cartridge; 2 Guard cartirdge units include two guard cartridges.<br />

related products<br />

For prep Vydac ® TP Columns, see our prep section<br />

pages 158–160.<br />

related products<br />

Looking for HPLC column<br />

prefilters? See page 111.<br />

related products<br />

Need high-pressure<br />

polymeric fittings?<br />

See pages 112–114<br />

for our full selection of<br />

high-pressure fittings.<br />

6673<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

related products<br />

Need HPLC tubing?<br />

See pages 384–391.<br />

5535<br />

92<br />

www.discoverysciences.com


analytical hplc<br />

Vydac ® ProZap C18<br />

Ultra Fast Protein and Peptide Separations<br />

3 4<br />

• 10 times faster bioseparations than traditional column formats 1 2 5<br />

• Ultra-high efficiency 1.5μm packing<br />

• Fast protein and peptide separations with conventional HPLC systems<br />

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Min.<br />

ProZap 1.5μm, 500Å packings are ideal for fast bioseparations in life science applications. The<br />

combination of ProZap packings and short, 10mm Expedite column hardware delivers not only<br />

faster sample throughput, but also low back pressures suitable for conventional LC systems.<br />

Optimization of Gradient Parameters for Fast Protein Analysis<br />

4<br />

Short ProZap columns are the perfect tool for fast reversed-phase protein separations. Under gradient conditions, longer<br />

6<br />

columns only increase run time and do not increase resolution to improve the separation. 3 Proteins adsorb at the head of the<br />

column and then desorb once the critical mobile phase concentration is reached. Since the proteins 7 do not interact with the full<br />

length of the packed bed, short columns are sufficient for full resolution. Therefore, proteins of broad molecular weight ranges<br />

1 2 5<br />

can be separated in less than one minute by combining short columns, higher flow rates, and fast, modified gradients. For best<br />

results high-pressure mixing should be used with fast gradients.<br />

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Min.<br />

ProZap C18 Specifications<br />

Phase Base Material Particle Shape Particle Size Pore Size Surface Area Carbon Load Phase Type Endcapped? USP L-code<br />

C18 ProZap Silica Spherical 1.5µm 500Å 59m 2 /g 3% Monomeric Yes L1<br />

6<br />

7<br />

7279<br />

hplc columns | large molecule<br />

Proteins<br />

3 4 6<br />

7<br />

1 2 5<br />

1. Ribonuclease (37ng)<br />

2. Bovine Insulin (37ng)<br />

3. Cytochrome C (37ng)<br />

4. Lysozyme (4ng)<br />

5. Bovine Serum Albumin (37ng)<br />

6. Carbonic Anhydrase (37ng)<br />

7. Ovalbumin (37ng)<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Min.<br />

Flow Rate: 0.8mL/min<br />

Backpressure: 185bar = 2680psig<br />

Gradient: Time: 0 1.0 1.1 1.2<br />

%B: 23 75 75 23<br />

3<br />

1 2<br />

4<br />

5<br />

6<br />

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Min.<br />

Flow Rate: 0.4mL/min<br />

Backpressure: 95bar = 1380psig<br />

Gradient: Time: 0 4.0 4.5 4.7<br />

%B: 23 75 75 23<br />

4<br />

6<br />

3<br />

more info<br />

7<br />

For more information 2 about the Expedite hardware format,<br />

see page 31. 1<br />

5<br />

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Min.<br />

7<br />

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Min.<br />

Flow Rate: 0.2mL/min<br />

Backpressure: 45bar = 650psig<br />

Gradient: Time: 0 4.0 4.5 4.7<br />

%B: 23 75 75 23<br />

Column: ProZap C18, 2.1 x 10mm, C18, 1.5µm, 500Å<br />

HPLC System: High-pressure gradient, binary pump<br />

Mobile Phase: A: 0.1% TFA in Water<br />

B: 0.085% TFA in Acetonitrile<br />

Detector: UV at 280nm<br />

Injection Vol: 5µL<br />

Injection Amt: 37ng each protein, except 4ng for lysozyme<br />

Column Temp: 25°C<br />

Seven proteins were tested on a 10mm ProZap column. By increasing flow rate and reducing gradient time, total run time is reduced from<br />

4.5 minutes to 1.2 minutes.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

6113<br />

www.discoverysciences.com 93


analytical hplc<br />

hplc columns | large molecule<br />

Vydac ® ProZap Columns<br />

2<br />

1<br />

2<br />

Antibodies in Sheep Serum<br />

ProZap vs. Ion Exchange<br />

0 1 2 3 4 5 6 Min.<br />

3<br />

4<br />

5<br />

Peptides<br />

1. Albumin<br />

2. IgG<br />

Column: ProZap C18, 2.1 x 10mm, C18, 1.5µm, 500Å<br />

HPLC System: High-pressure gradient, binary pump<br />

Mobile Phase: A: 0.1% TFA in Water<br />

B: 0.085% TFA in 90:10 n-propanol:water<br />

Gradient: Time: 0.0 6.0 6.5 7.0<br />

%B: 5 75 75 5<br />

Flow Rate: 0.5mL/min<br />

Detector: UV at 280nm<br />

Injection Vol: 5µL<br />

Column Temp: 75°C<br />

Backpressure: 170bar = 2465psig<br />

1. GY (238 Da)<br />

2. VYV (379 Da)<br />

3. Met Enkephalin (YGGFM, 573 Da)<br />

4. Leu Enkephalin (YGGFL, 555 Da)<br />

5. Angiotensin II (DRVYIHPF, 1045 Da)<br />

Separation of Antibodies in Sheep Serum<br />

1<br />

0 3 5 7 9 11 13 15 Min.<br />

2<br />

1. IgG<br />

2. Albumin<br />

Column: DEAE-type anion exchange, 7.5 x 50mm)<br />

Mobile Phase: 10mM HEPES/TEA, pH 8.0<br />

Gradient: 0 to 0.5 M NaCl in 20min<br />

Vydac ® ProZAP columns separate intact IgG antibodies (150 kDa)<br />

rapidly. Other traditional HPLC methods, such as ion exchange take<br />

longer and typically involve the use of non-volatile buffers.<br />

Synthetic Peptides —10 Injections<br />

1<br />

2 3 4 5<br />

1. Contaminant peptides/impurities<br />

2. RGAGGLGLGK-amide (883 Da)<br />

3. Ac-RGAGGLGLGK-amide (926 Da)<br />

4. Ac-RGVGGLGLGK-amide (954 Da)<br />

5. Ac-RGVVGLGLGK-amide (996 Da)<br />

1<br />

0 0.2 0.4 0.6 0.8 1.0 1.2 Min.<br />

Column: ProZap C18, 2.1 x 10mm, C18, 1.5µm, 500Å<br />

HPLC System: High-pressure gradient, binary pump<br />

Mobile Phase: A: 0.1% TFA in Water<br />

B: 0.085% TFA in 80:20 Acetonitrile:Water<br />

Gradient: Time: 0.0 0.1 0.7 1.1 1.2<br />

%B: 4 15 20 50 4<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 215nm<br />

Injection Vol: 5µL<br />

Injection Amt: 600ng each, except 200ng for GY<br />

Column Temp: 25°C<br />

Backpressure: 180bar = 2610psig<br />

Peptides under one minute.<br />

0 0.2 0.4 0.6 0.8 1.0 Min.<br />

Column: ProZap C18, 2.1 x 10mm, C18, 1.5µm, 500Å<br />

HPLC System: High-pressure gradient, binary pump<br />

Mobile Phase: A: 0.1% TFA in Water<br />

B: 0.085% TFA in 80:20 Acetonitrile:Water<br />

Gradient: Time: 0.0 0.1 0.7 1.1 1.2<br />

%B: 4 15 20 50 4<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 215nm<br />

Injection Vol: 5µL<br />

Injection Amt: 500ng each<br />

Column Temp: 25°C<br />

Backpressure: 180bar = 2610psig<br />

Reproducibly separate synthetic peptides can be in one minute.<br />

ProZap (1.5µm)<br />

Dimension 2.1 x 10mm 2.1 x 20mm 4.6 x 10mm 4.6 x 20mm 7 x 33mm<br />

Part No. 35585 35587 35586 35588 35589<br />

94<br />

www.discoverysciences.com


analytical hplc<br />

Vydac ® Venture ® A<br />

Protein A Affinity Columns for Antibody<br />

Purification<br />

• High binding capacity for polyclonal and monoclonal<br />

antibodies<br />

• No non-specific binding—patented ICEtech (Inert<br />

Coating Enhancement Technology, U.S. Patent No.<br />

6,802,966) completely passivates the silica surface to<br />

ensure highly purified antibodies<br />

• Long lifetime—proven over 300 runs<br />

• Standard HPLC column format uses biocompatible PEEK<br />

hardware for use with HPLC or FPLC instruments<br />

The Venture ® A column is the first affinity column to take<br />

advantage of silica’s rigid porous structure, providing<br />

increased productivity over other supports. <strong>Grace</strong>’s<br />

patented technology, ICEtech (inert coating enhancement<br />

technology), eliminates non-specific binding on the silica<br />

surface enabling the breakthrough use of silica for affinity<br />

separations.<br />

Venture ® A columns use a recombinant protein A ligand for<br />

binding antibodies. They are designed to perform both as an<br />

analytical tool for fast, accurate measurement of antibody<br />

titers and as a quick and easy way to purify antibodies from<br />

cell culture supernate, serum, or other feedstocks.<br />

High Recovery: Experience Up to a 10%<br />

Improvement in Recovery Compared to Other<br />

Commercially Available Columns, Increasing Your<br />

Yield and Measurement Accuracy<br />

20mM Phosphate and 0.15M NaCl Buffer pH 7.4 was loaded<br />

on each column up to 90% of the total capacity. After loading<br />

the columns were washed with phosphate buffer and the IgG<br />

eluted with citrate buffer pH 3.2.<br />

% Recovery<br />

90<br />

88<br />

86<br />

84<br />

82<br />

80<br />

78<br />

76<br />

Venture ® A Column A Column B Column C<br />

IgG Purification from Bovine Serum<br />

2<br />

1. Serum Load Passthrough<br />

2. IgG<br />

hplc columns | large molecule<br />

Venture ® A Characteristics<br />

Composition:<br />

Wide-porous spherical silica treated with<br />

ICEtech surface passivation technology<br />

Particle Size:<br />

15–20µm<br />

Ligand:<br />

Recombinant protein A<br />

pH Range:<br />

pH 1 to 8 (long term), pH 1 to 9 (short term)<br />

Pressure: Maximum operating pressure =<br />

3000psig (200bar)<br />

Recommended 500cm/h<br />

Mobile-Phase Velocity:<br />

Mobile-Phase<br />

150–5000cm/h<br />

Velocity Range:<br />

Delivery Conditions: 20% ethanol<br />

Storage:<br />

At +4 to +8°C in 20% ethanol<br />

Chemical Stability: Stable in all aqueous buffers with pH 1 to 8<br />

commonly used in protein A chromatography<br />

Static Capacity of Venture ® A Affinity Columns<br />

Polyclonal<br />

Species<br />

Capacity (mg/mL)<br />

human 40<br />

bovine 23<br />

mouse 38<br />

rabbit 37<br />

sheep 13<br />

Monoclonal<br />

Subclass<br />

Capacity (mg/mL)<br />

IgG1 Kappa 15<br />

IgG2a 29<br />

IgG2b 23<br />

1<br />

0 5 15 25 35 45 Min.<br />

Column:<br />

Flow Rate:<br />

Mobile Phase:<br />

Gradient:<br />

Detector:<br />

Venture ® A RAVE1520405 (Recombinant<br />

Protein A, 15 – 20µm, 4.6 x 50mm)<br />

1.38mL/min (linear velocity = 500cm/hr)<br />

A: 20mM phosphate, pH 7.4, 150mM NaCl<br />

B: 0.1M sodium citrate, pH 3.2<br />

Equilibrate with A for 3min, load sample for 9min,<br />

wash with A for 12min, elute with B for 3min,<br />

re-equilibrate with A for 6min<br />

UV at 280nm<br />

Venture ® A Affinity Columns<br />

Particle Size i.d. 50mm 100mm<br />

15 –20µm 2mm RAVE1520205 —<br />

4.6mm RAVE1520405 RAVE1520410<br />

7.5mm — RAVE1520710<br />

NOTE: Additional column diameters and lengths are available on request. Please<br />

contact <strong>Grace</strong> Davison Discovery Sciences to discuss your requirements.<br />

related products<br />

Venture ® Immunoaffinity columns are also developed for small molecules, which have been fully validated. Applications areas include:<br />

Food (Aflatoxin, Lactoferrin, Vitamin B12, Testosterone, Nortestosterone), Endocrine Disruptors (17α-Ethynyl Estradiol, 17β-Estradiol,<br />

Estrone, Bisphenol A) and Pollutants (Chlorophenoxy Acetic Acid Herbicides, Phenylurea Herbicides, Organophosphorus Pesticides,<br />

Vinclozolin Fungicide). For details, visit www.discoverysciences.com.<br />

www.discoverysciences.com 95


analytical hplc<br />

hplc columns | large molecule<br />

Alltech ® ProSphere HP 300Å Columns<br />

• High recoveries at low sample concentrations and<br />

low TFA concentrations<br />

• Use for protein, peptides, sequencing, nucleic acid<br />

fragments<br />

• pH range 2–7.5<br />

These columns produce sharp symmetrical peaks even<br />

for basic biomolecules. The 300Å pores allow access of<br />

large proteins while still maintaining high resolution of<br />

small peptides.<br />

A C4 Competitive Comparison<br />

1<br />

2<br />

3<br />

0 5 10 15 20 25 30 Min.<br />

4<br />

5<br />

10466<br />

10467<br />

1. Ribonuclease A (0.2mg/mL)<br />

2. Insulin (0.067mg/mL)<br />

3. Lysozyme (0.2mg/mL)<br />

4. Myoglubin (0.2mg/mL)<br />

5. Ovalbumin (0.4mg/mL)<br />

A. ProSphere HP C4<br />

B. Leading Competitive C4<br />

ProSphere HP 300Å HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 3µm* Capillary 0.150 x 50mm 35510<br />

Capillary 0.150 x 150mm 35423<br />

Capillary 0.150 x 150mm 35516<br />

Capillary 0.300 x 50mm 35511<br />

Capillary 0.300 x 100mm 35424<br />

Capillary 0.300 x 150mm 35517<br />

Solvent Reducer 3.0 x 50mm 35512<br />

Solvent Reducer 3.0 x 150mm 35518<br />

Analytical 4.6 x 50mm 35513<br />

Analytical 4.6 x 150mm 35520<br />

C18, 5µm Solvent Reducer 3.0 x 150mm 35519<br />

Solvent Reducer 3.0 x 250mm 35522<br />

Analytical 4.6 x 150mm 35521<br />

Analytical 4.6 x 250mm 35523<br />

C4, 3µm* Capillary 0.150 x 50mm 35533<br />

Capillary 0.150 x 150mm 35464<br />

Capillary 0.150 x 150mm 35539<br />

Capillary 0.300 x 50mm 35534<br />

Capillary 0.300 x 100mm 35465<br />

Capillary 0.300 x 150mm 35545<br />

Solvent Reducer 3.0 x 50mm 35535<br />

Solvent Reducer 3.0 x 150mm 35547<br />

Analytical 4.6 x 50mm 35536<br />

Analytical 4.6 x 150mm 35549<br />

C4, 5µm Solvent Reducer 3.0 x 150mm 35548<br />

Solvent Reducer 3.0 x 250mm 35561<br />

Analytical 4.6 x 150mm 35560<br />

Analytical 4.6 x 250mm 35562<br />

*5µm, 10µm particles and other dimensions are also available.<br />

Column: C4, 5μm, 300Å, 4.6 x 150mm (Part No. 35560)<br />

Mobile Phase: A: 0.01%TFA in Water<br />

B: 0.01%TFA in Acetonitrile<br />

Gradient: Time: 0 40<br />

%B: 20 100<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

Injection Vol.: 10µL<br />

Even at very low concentrations of TFA, ProSphere HP C4 exhibits<br />

excellent recoveries; significantly better than a leading competitive<br />

C4 column.<br />

ProSphere HP 300Å All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

300Å C18, 5µm 3.0 x 7.5mm 3 35526<br />

4.6 x 7.5mm 3 35527<br />

HP C18, 3µm<br />

Capillary Guard**<br />

0.150 x 10mm — 22668<br />

0.300 x 10mm — 22669<br />

300Å C4, 5µm* 3.0 x 7.5mm 3 35565<br />

4.6 x 7.5mm 3 35566<br />

HP C4 Capillary Guard** 0.150 x 10mm — 22678<br />

0.300 x 10mm — 22679<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

Capillary Guard Cartridge Holder<br />

Guard Holder for 0.100mm and 0.150mm Guards ea GR-3710E<br />

Guard Holder for 0.300mm and 0.500mm Guards ea GR-3710A<br />

*All-Guard holder required. Other particle sizes available.<br />

**5µm, 10µm particles and other dimensions are also available.<br />

Table 1—Percent Protein Recovery at Low Sample Concentration<br />

Insulin Ribonuclease A Lysozyme Bovine Serum Albumin Human Serum Albumin<br />

Phase<br />

0.02mg/mL 0.4mg/mL 0.02mg/mL 0.4mg/mL 0.02mg/mL 0.4mg/mL 0.02mg/mL 0.4mg/mL 0.02mg/mL 0.4mg/mL<br />

ProSphere HP C18 68 94 74 94 45 87 65 90 66 87<br />

A Leading Competitive C18 13 90 0 84 0 74 0 63 0 63<br />

ProSphere HP C4 79 95 79 94 64 92 74 93 72 89<br />

A Leading Competitive C4 31 93 53 91 20 75 0 53 0 68<br />

Every column has good recoveries with high sample concentrations. How does your column compare at low sample concentrations?<br />

ProSphere HP 300Å phases outperform a leading competitor at 0.02mg/mL.<br />

related products<br />

Looking for ProSphere prep columns?<br />

See page 161.<br />

96<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® ProSphere <br />

HP C18-AQ Columns<br />

Ideal for Peptide Mapping<br />

• Stable from 100% aqueous to 100% organic<br />

mobile phases<br />

• Compatible with a broad range of LC/MS compatible<br />

mobile phases<br />

ProSphere HP C18-AQ Specifications<br />

Base Material<br />

Silica<br />

Particle Size 3µm, 5µm<br />

Pore Size<br />

100Å<br />

pH Range 2–8<br />

Tryptic Digest of Cytochrome C<br />

0 10 20 30 40 50 Min.<br />

10492<br />

10493<br />

A. C18-AQ<br />

B. Competitive C18<br />

Alltech ® Macrosphere <br />

GPC Columns<br />

• 7µm GPC phases separate proteins, peptides, and polar<br />

synthetic compounds by size-exclusion<br />

Macrosphere GPC Exclusion Limits in Daltons<br />

Pore Size Included Excluded<br />

60Å 250 28,000<br />

100Å 2500 350,000<br />

150Å 4000 500,000<br />

300Å 7500 1,200,000<br />

Macrosphere GPC Columns<br />

Standard<br />

Part No.<br />

Waters ® Fittings<br />

Part No.<br />

Packing Format i.d. x Length<br />

GPC 60Å Analytical 4.6 x 250mm 88129 88130<br />

Semi-Prep 7.5 x 300mm 88175 —<br />

GPC 100Å Analytical 4.6 x 250mm 88133 88134<br />

Semi-Prep 7.5 x 300mm 88177 —<br />

GPC 150Å Analytical 4.6 x 250mm 88137 88138<br />

Semi-Prep 7.5 x 300mm 88179 —<br />

GPC 300Å Analytical 4.6 x 250mm 88141 88142<br />

Semi-Prep 7.5 x 300mm 88181 —<br />

Macrosphere GPC All-Guard Cartridges*<br />

Packing, 5µm i.d. x Length Qty. Part No.<br />

GPC 4.6 x 7.5mm 3 96133<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

hplc columns | large molecule<br />

Column: 5µm, 4.6 x 150mm (Part No. 35579)<br />

Mobile Phase: A: 5mM Acetic Acid in Water<br />

B: 5mM Acetic Acid in Acetonitrile<br />

Gradient: Time: 0 50<br />

%B: 0 40<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 220nm<br />

Column Temp: 35°C<br />

This water-wettable phase is ideally suited for LC/MS and delivers<br />

more peaks than traditional C18 phases.<br />

ProSphere HP C18-AQ HPLC Columns<br />

Packing Format i.d. x Length Part No.<br />

C18-AQ, 3µm Capillary 150µm x 50mm 35568<br />

Capillary 150µm x 150mm 35574<br />

Capillary 300µm x 50mm 35569<br />

Capillary 300µm x 150mm 35575<br />

Solvent Reducer 3.0 x 50mm 35570<br />

Solvent Reducer 3.0 x 150mm 35576<br />

Analytical 4.6 x 50mm 35571<br />

Analytical 4.6 x 150mm 35578<br />

C18-AQ, 5µm Solvent Reducer 3.0 x 150mm 35577<br />

Solvent Reducer 3.0 x 250mm 35580<br />

Analytical 4.6 x 150mm 35579<br />

Analytical 4.6 x 250mm 35581<br />

ProSphere HP C18-AQ All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

C18-AQ, 5µm 3.0 x 7.5mm 3 35582<br />

4.6 x 7.5mm 3 35583<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

Alltech ® Macrosphere <br />

Ion-Exchange Columns<br />

• 300Å weak and strong ion-exchange phases separate<br />

proteins, enzymes, and other biologicals<br />

Macrosphere Ion-Exchange Specifications<br />

Exchange Group<br />

Exchange Capacity<br />

WAX Diethylaminoethane 0.13 meq/gram<br />

WCX Carboxylic Acid 0.49 meq/gram<br />

SAX Quaternary Ammonium 0.14 meq/gram<br />

SCX Sulfonic Acid 0.50 meq/gram<br />

Macrosphere Ion-Exchange Columns<br />

Packing Format i.d. x Length Part No.<br />

WAX, 7µm Analytical 4.6 x 150mm 71151<br />

Analytical 4.6 x 250mm 71154<br />

WCX, 7µm Analytical 4.6 x 150mm 71157<br />

Analytical 4.6 x 250mm 71160<br />

SAX, 7µm Analytical 4.6 x 150mm 72303<br />

Analytical 4.6 x 250mm 72603<br />

SCX, 7µm Analytical 4.6 x 150mm 72308<br />

Analytical 4.6 x 250mm 72608<br />

Macrosphere Ion-Exchange All-Guard Cartridges*<br />

Packing i.d. x Length Qty. Part No.<br />

WAX, 5µm 4.6 x 7.5mm 3 96135<br />

WCX, 5µm 4.6 x 7.5mm 3 96137<br />

SAX, 5µm 4.6 x 7.5mm 3 96139<br />

SCX, 5µm 4.6 x 7.5mm 3 96141<br />

All-Guard Cartridge Holder<br />

ea 80101<br />

(Includes Direct-Connect Column Coupler)<br />

*All-Guard holder required. Other particle sizes available.<br />

www.discoverysciences.com<br />

97


analytical hplc<br />

IC Columns Introduction<br />

hplc columns | ion chromatography<br />

Alltech ® IC Column Specifications<br />

Column Composition pH Range Applications<br />

Anion Exchange Columns<br />

Allsep polymer-based anion pH 2–10 inorganic anions, weak and strong acid ions,<br />

exchanger, 7µm<br />

metal complexes, organic acids<br />

Allsep A-2 polymer-based anion pH 2–11 inorganic anions, organic acids, suitable for<br />

exchanger, 7µm<br />

both weak and strong anions in a single run<br />

Novosep A-2 polymer-based anion pH 3–12 inorganic anions and oxyhalides; ideal for<br />

exchanger, 5µm<br />

separation of seven common anions plus<br />

three oxyhalide anions in one run<br />

AN1<br />

polymer-based anion<br />

exchanger, 9µm<br />

Anion/S silica-based anion<br />

exchanger, 10µm<br />

Anion/R polymer-based anion<br />

exchanger, 10µm<br />

PRP-X100 polymer-based anion<br />

exchanger, 10µm<br />

Cation Exchange Columns<br />

Universal Cation silica-based cation<br />

exchanger, 7µm<br />

Universal Cation silica-based cation<br />

HR<br />

exchanger, 3µm<br />

PRP-X200 polymer-based cation<br />

exchanger, 10µm<br />

Organic Acid Columns<br />

PRP-X300 polymer-based sulfonated<br />

cation exchanger<br />

Anion Exclusion polymer-based cation<br />

exchanger, 10µm<br />

Specialty Columns<br />

Transition Metal silica-based reversedphase,<br />

3µm and 7µm<br />

Surfactant/R<br />

Surfactant C8<br />

Surfactant C18<br />

polymer-based<br />

reversed-phase, 7µm<br />

silica-based reversedphase,<br />

5µm<br />

silica-based reversedphase,<br />

5µm<br />

EPA<br />

Methods<br />

Optimized for Suppressed<br />

or Non-Suppressed<br />

Conductivity<br />

300.0,<br />

Part A<br />

both 99<br />

300.0, both 99<br />

Part A<br />

300.0, suppressed 100<br />

300.1,<br />

317.0,<br />

326.0<br />

pH 2–13 inorganic anions, weak and strong acid ions, — both 100<br />

organic acids<br />

pH 2–5.5 inorganic anions — non-suppressed 101<br />

pH 2–12 inorganic anions, weak and strong acid ions — non-suppressed 101<br />

pH 1–13 inorganic anions, weak and strong acid ions — non-suppressed 103<br />

pH 2–7<br />

pH 2–7<br />

pH 1–13<br />

groups I and II cations, amines, divalent<br />

transition metals<br />

groups I and II cations, amines, divalent<br />

transition metals; smaller particle size for<br />

improved peak resolution<br />

groups I and II cations (separate runs),<br />

amines, lanthanides<br />

Page<br />

300.7 both 102<br />

300.7 both 102<br />

— non-suppressed 103<br />

pH 1–13 simple aliphatic carboxylic acids and alcohols — non-suppressed 103<br />

pH 1–13 organic acids, weak acid anions — non-suppressed 104<br />

pH 2–7 high capacity, separates divalent transition<br />

metals and metal-cyano complexes more<br />

selectively than a cation exchange column<br />

— non-suppressed 104<br />

pH 1–14 anionic and cationic surfactants; separate — both 105<br />

short and long chain surfactants in one<br />

gradient run<br />

pH 2–7 short chain anionic surfactants — non-suppressed 105<br />

pH 2–7 long chain or aromatic anionic surfactants — non-suppressed 105<br />

IC Guard Kits Cross Reference<br />

Kit includes holder and three guard cartridges.<br />

Guard Reference Table<br />

Guard Cartridge<br />

Type<br />

All-Guard Kit<br />

Part No.<br />

Brand Column Type<br />

Alltech Allsep, Allsep A-2 GA-1 38109<br />

Novosep A-2 GA-1 38109<br />

Anion/R, Anion/S GA-1 38109<br />

Universal Cation GC-2 27109<br />

Universal Cation HR GC-3 23115<br />

Anion Exclusion GIE-1 38117<br />

Transition Metal C18 GRP-2 38123<br />

Surfactant/R GRP-1 38122<br />

Surfactant C8, C18 GRP-2 38123<br />

Dionex<br />

IonPac ® AS4A-SC, AS7, AS11, GA-1 38109<br />

AS22, AS24, AS26, AS27<br />

IonPac ® CS3, CS10, CS11 GC-1 38113<br />

IonPac ® CS12, CS14, CS15 GC-2 27109<br />

IonPac ® NS1 GRP-1 38122<br />

IonPac ® AS1, AS5 GIE-1 38117<br />

Guard Reference Table (continued)<br />

Guard Cartridge<br />

Type<br />

All-Guard Kit<br />

Part No.<br />

Brand Column Type<br />

Waters IC-Pak-A GA-1 38109<br />

IC-Pak-M/D GC-2 27109<br />

Ion Exclusion GIE-1 38117<br />

Hamilton PRP-X100 GA-1 38109<br />

PRP-X200 GC-1 38113<br />

PRP-X300 GIE-1 38117<br />

Misc. Sarasep ANIONSEP AN1 GA-1 38109<br />

Bio-Rad ® , Aminex ® , HPX-87 GIE-1 38117<br />

Interaction ION-120 GA-1 38109<br />

Interaction ION-210 GC-1 38113<br />

Interaction ORH-801 GIE-1 38117<br />

Metrohm ® Metrosep GA-1 38109<br />

more info<br />

Cartridges and holders can also be purchased separately.<br />

See specific phase pages for replacement cartridge ordering<br />

information.<br />

98<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Anion Columns<br />

Allsep Anion IC Columns<br />

• Resolves fluoride away from the water dip<br />

• Meets requirements for U.S. EPA Method 300.0 part A<br />

The Allsep Anion Column is compatible with common IC<br />

mobile phases: carbonate, bicarbonate, p-hydroxybenzoic<br />

acid, phthalic acid, succinic acid, and sodium octane<br />

sulfonate.<br />

Use this column for performing EPA Method 300.0 Part A<br />

“Determination of Inorganic Anions in Water” per U.S. EPA<br />

guidelines.<br />

1<br />

2<br />

3<br />

4<br />

Resolves Fluoride Away<br />

from the Water Dip<br />

5<br />

6<br />

7<br />

13033<br />

1. Fluoride<br />

2. Chloride<br />

3. Nitrite<br />

4. Bromide<br />

5. Nitrate<br />

6. Phosphate<br />

7. Sulfate<br />

Allsep A-2 Anion IC Columns<br />

• Separates both weak and strong acid anions in one run<br />

• Resolves formate away from fluoride and chloride<br />

The Allsep A-2 Anion Column separates both weakly<br />

retained organic and strongly retained inorganic anions<br />

in one run. The high capacity Allsep A-2 Anion Column<br />

is also suitable for the separation of chlorite and chlorate.<br />

1<br />

3<br />

4<br />

2<br />

5<br />

6<br />

Organic and Inorganic Anions<br />

7<br />

8<br />

9<br />

10<br />

11<br />

8747<br />

1. Fluoride (1.0ppm)<br />

2. Acetate (1.0ppm)<br />

3. Formate (1.0ppm)<br />

4. Chlorite (1.0ppm)<br />

5. Chloride (2.0ppm)<br />

6. Nitrite (2.0ppm)<br />

7. Bromide (2.0ppm)<br />

8. Chlorate (5.0ppm)<br />

9. Nitrate (2.0ppm)<br />

10. Phosphate (3.0ppm)<br />

11. Sulfate (3.0ppm)<br />

hplc columns | ion chromatography<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 Min.<br />

0 6<br />

12 18 24 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Allsep Anion, 7µm, 4.6 x 100mm<br />

(Part No. 51207)<br />

0.85mM NaHCO3/0.9mM Na2CO3<br />

1.2mL/min<br />

Suppressed Conductivity<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Allsep A-2 Anion, 7µm, 4.6 x 100mm<br />

(Part No. 51219)<br />

2.1mM NaHCO3/1.6mM Na2CO3<br />

2.0mL/min<br />

Suppressed Conductivity<br />

Allsep Anion Specifications<br />

Composition:<br />

Methacrylate based w/quaternary ammonium<br />

functional groups<br />

Particle Size: 7µm<br />

Mobile Phase Limits: pH 2–10, 0–100% organic modifier<br />

Allsep A-2 Anion Specifications<br />

Composition:<br />

Methacrylate based w/quaternary alkanol<br />

amine functional groups<br />

Particle Size: 7µm<br />

Mobile Phase Limits: pH 2–11, 0–100% organic modifier<br />

Allsep Anion Columns<br />

Packing i.d. x Length PEEK Part No. SS Part No.<br />

Allsep Anion 4.6 x 30mm 51217 51216<br />

4.6 x 50mm 51213 51214<br />

4.6 x 100mm 51207 51200<br />

4.6 x 150mm 51209 51208<br />

Allsep A-2 Anion Columns<br />

Packing i.d. x Length PEEK Part No. SS Part No.<br />

Allsep A-2 4.6 x 50mm 51221 51220<br />

4.6 x 100mm 51219 51218<br />

related product<br />

Save money with IC All-Guard Kits on page 98. Kit includes one<br />

holder and three cartridges.<br />

Guards for Allsep and AllsepA-2 Columns<br />

Description Qty. Part No.<br />

GA-1 Anion Cartridges 3 38108<br />

All-Guard Cartridge Holder* ea 80101<br />

*Direct-Connect column coupler included.<br />

www.discoverysciences.com<br />

99


analytical hplc<br />

hplc columns | ion chromatography<br />

Alltech ® Anion Columns<br />

Novosep A-2 Anion IC Columns<br />

• Separates seven inorganic anions and three oxyhalide<br />

anions in a single run<br />

• Meets the requirements of U.S. EPA Methods 300.0,<br />

300.1, 317.0, and 326.0<br />

The Novosep A-2 Anion Column is ideal for the<br />

separation of 10 inorganic anions by suppressor-based ion<br />

chromatography using U.S. EPA Method 300.1. The column<br />

can also be used to determine inorganic anions in drinking<br />

water per U.S. EPA Method 300.0 and trace bromate in<br />

drinking water using U.S. EPA Methods 317.0 and 326.0.<br />

1<br />

Anions in High Ionic Strength Water<br />

by EPA Method 300.0<br />

2<br />

3<br />

4 5<br />

67<br />

8<br />

9 10 11<br />

10121<br />

1. Fluoride<br />

2. Chlorite<br />

3. Bromate<br />

4. Chloride<br />

5. Nitrite-N<br />

6. Bromide<br />

7. Chlorate<br />

8. Dichloroacetate<br />

9. Nitrate-N<br />

10. Phosphate-P<br />

11. Sulfate<br />

IC Sep AN1 IC Column<br />

• Separates anions with carbonate/bicarbonate and<br />

hydroxide mobile phases<br />

The IC Sep AN1 Column is compatible with both<br />

suppressor-based and non-suppressed detection. A variety<br />

of mobile phases including sodium carbonate/bicarbonate,<br />

sodium hydroxide, and borate/gluconate may be used.<br />

Separation of Sulfite and Sulfate<br />

1<br />

2 3 4 5<br />

6<br />

7<br />

8<br />

6316<br />

1. Fluoride<br />

2. Chloride<br />

3. Nitrite<br />

4. Bromide<br />

5. Nitrate<br />

6. Phosphate<br />

7. Sulfite<br />

8. Sulfate<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 26 Min.<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Novosep A-2 Anion, 5µm, 4.0 x 250mm<br />

(Part No. 51410)<br />

3.6mM NaHCO3<br />

0.8mL/min<br />

Suppressed Conductivity<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

IC Sep AN1, 9µm, 4.6 x 250mm<br />

(Part No. 38140)<br />

1.8mM NaHCO3, 1.8mM Na2CO3<br />

1.0mL/min<br />

Suppressed Conductivity<br />

Novosep A-2 Anion Specifications<br />

Composition:<br />

Polyvinyl alcohol-based w/quaternary<br />

ammonium functional groups<br />

Particle Size: 5µm<br />

Mobile Phase Limits: pH 3–12, 0–100% organic modifier,<br />

10% modifier is practical upper limit<br />

IC Sep AN1 Specifications<br />

Composition:<br />

Poly(styrene-divinylbenzene) alkyl dimethyl<br />

ethanol ammonium functional group<br />

Particle Size: 9µm<br />

Exchange Capacity: 0.05meq/g<br />

Mobile Phase Limits: pH 2–13, No organic solvents<br />

Novosep A-2 Anion Column<br />

Packing i.d. x Length PEEK Part No.<br />

Novosep A-2 4.0 x 250mm 51410<br />

Guards for Novosep A-2 Anion Columns<br />

Description Qty. Part No.<br />

GA-1 Anion Cartridges 3 38108<br />

All-Guard Cartridge Holder* ea 80101<br />

*Direct-Connect column coupler included.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

IC Sep AN1 Columns<br />

Packing i.d. x Length Part No.<br />

AN1 4.6 x 250mm 38140<br />

Choose a guard column or integral guard discs to protect your<br />

IC Sep Column.<br />

IC Sep Guards<br />

Description Qty. Part No.<br />

Guard Column, 50 x 4.6mm ea 38145<br />

Guard Column Guard-Disc 5 38146<br />

100<br />

www.discoverysciences.com


analytical hplc<br />

Alltech ® Anion Columns<br />

Anion/S IC Columns<br />

• Silica-based for symmetrical peak shapes<br />

• Separates inorganic and organic anions<br />

The Anion/S Columns are best suited for routine separations<br />

of chloride, bromide, nitrate, and sulfate. Not suitable for<br />

fluoride analysis.<br />

1<br />

2<br />

3 4<br />

0 4 8 12 16 20 24 Min.<br />

EDTA and Other Anions<br />

8284<br />

1. Nitrite<br />

2. EDTA<br />

3. Nitrate<br />

4. Bromide<br />

Column: Anion/S, 10µm, 4.6 x 100mm (Part No. 269012)<br />

Mobile Phase: 1.5mM Sulfuric Acid<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 210nm<br />

Anion/R IC Columns<br />

• Polymer-based for broad pH stability<br />

• Separates seven common inorganic anions<br />

Because of their high pH stability, these columns are ideal<br />

for the separation of anions using high pH mobile phases<br />

such as p-hydroxybenzoate, sodium hydroxide, and sodium<br />

carbonate/bicarbonate. The larger dimension columns<br />

(150mm and 250mm) are suitable for a high-resolution<br />

separation of the seven common inorganic anions.<br />

1<br />

2 3 45<br />

6<br />

Weak Acid Anions<br />

5697<br />

1. Borate (5ppm)<br />

2. Silicate (10ppm)<br />

3. Formate (10ppm)<br />

4. Sulfide (10ppm)<br />

5. Chloride (20ppm)<br />

6. Cyanide (20ppm)<br />

hplc columns | ion chromatography<br />

Anion/S Specifications<br />

Composition:<br />

Silica w/quaternary ammonium ion<br />

exchanger<br />

Particle Size: 10µm<br />

Exchange Capacity: 0.25meq/g<br />

Mobile Phase Limits: pH 2–5.5, 0–100% organic modifier<br />

0 9 18 Min.<br />

Column: Anion/R, 10µm, 4.1 x 250mm (Part No. 269029)<br />

Mobile Phase: 4mM Sodium Hydroxide/ 0.1mM Sodium Benzoate<br />

Flow Rate: 1.5mL/min<br />

Detector: Conductivity<br />

Anion/S Columns<br />

Packing i.d. x Length PEEK Part No. SS Part No.<br />

Anion/S 4.6 x 100mm 269012 269013<br />

4.6 x 250mm 269011 269001<br />

Anion/R Specifications<br />

Composition:<br />

Poly(styrene-divinylbenzene)<br />

Trimethylammonium<br />

Particle Size: 10µm<br />

Exchange Capacity: 0.19 ± 0.02meq/g<br />

Mobile Phase Limits: pH 2–12, 0–100% organic modifier<br />

related product<br />

Save money with IC All-Guard Kits on page 98. Kit includes one<br />

holder and three cartridges.<br />

Anion/R Columns<br />

Packing i.d. x Length PEEK Part No. SS Part No.<br />

Anion/R 4.1 x 100mm — 269031<br />

4.1 x 250mm — 269029<br />

4.6 x 100mm 269036 —<br />

4.6 x 150mm 269034 —<br />

Guards for Anion/S and Anion/R Columns<br />

Description Qty. Part No.<br />

GA-1 Anion Cartridges 3 38108<br />

All-Guard Cartridge Holder* ea 80101<br />

*Direct-Connect column coupler included.<br />

www.discoverysciences.com<br />

101


analytical hplc<br />

hplc columns | ion chromatography<br />

Alltech ® Cation Columns<br />

Universal Cation and Universal Cation HR IC Columns<br />

• Separate Groups I and II cations in one isocratic run<br />

• Separate transition metals without post-column reaction<br />

• New Universal Cation HR 3µm particle size for<br />

improved efficiency<br />

Compatible with a variety of mobile phases including<br />

complexing acids (citric acid, tartaric acid, oxalic acid),<br />

mineral acids (nitric acid, hydrochloric acid, sulfuric acid)<br />

and non-complexing organic acids (methanesulfonic acid).<br />

12<br />

3<br />

4<br />

1. Lithium (0.2ppm)<br />

2. Sodium (1.5ppm)<br />

3. Ammonium (1.5ppm)<br />

4. Potassium (2.5ppm)<br />

5 6 7<br />

8<br />

Metal Ions<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Min.<br />

9<br />

10318<br />

5. Nickel (2.5ppm)<br />

6. Zinc (2.5ppm)<br />

7. Cobalt (2.5ppm)<br />

8. Magnesium (2.0ppm)<br />

9. Calcium (2.0ppm)<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Min.<br />

Column:<br />

12 3<br />

4<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

5<br />

Cesium and Strontium<br />

6<br />

Universal Cation, 7µm, 4.6 x 100mm<br />

(Part No. 27106)<br />

3mM Methanesulfonic Acid<br />

1.0mL/min<br />

Conductivity<br />

7<br />

8<br />

13035<br />

1. Lithium (0.12ppm)<br />

2. Sodium (0.90ppm)<br />

3. Ammonium (0.90ppm)<br />

4. Potassium (1.5ppm)<br />

5. Cesium (0.8ppm)<br />

6. Magnesium (1.2ppm)<br />

7. Calcium (1.2ppm)<br />

8. Strontium (1.6ppm)<br />

Column: Universal Cation, 7µm, 4.6 x 100mm<br />

(Part No. 27106)<br />

Mobile Phase: 2mM Tartaric Acid/1mM Oxalic Acid<br />

Flow Rate: 1.0mL/min<br />

Detector: Conductivity<br />

Universal Cation Specifications<br />

Composition:<br />

Silica coated with polybutadiene/maleic acid<br />

copolymer<br />

Particle Size:<br />

3µm and 7µm, spherical<br />

Mobile Phase Limits: pH 2–7, 0–100% organic modifier<br />

2<br />

3<br />

4<br />

1<br />

Rapid Analysis of Monovalent<br />

and Divalent Cations<br />

5<br />

6<br />

13013<br />

1. Lithium<br />

2. Sodium<br />

3. Ammonium<br />

4. Potassium<br />

5. Magnesium<br />

6. Calcium<br />

Universal Cation Columns<br />

Packing i.d. x Length PEEK Part No. SS Part No.<br />

7µm 4.6 x 100mm 27106 27100<br />

3µm HR 4.6 x 100mm — 23100<br />

7.0 x 53mm — 23109<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

0 1 2 3<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

4 5 6 7 8 9 Min.<br />

Universal Cation HR, 3µm, 7.0 x 53mm<br />

(Part No. 23109)<br />

3mM Methanesulfonic Acid<br />

2.5mL/min<br />

Conductivity<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

Guards for Universal Cation Columns<br />

Description Qty. Part No.<br />

GC-2 Universal Cation 3 271010<br />

GC-3 Universal Cation HR 3 23110<br />

All-Guard Cartridge Holder* ea 80101<br />

*Direct-Connect column coupler included.<br />

related product<br />

Save money with IC All-Guard Kits on page 98. Kit includes one<br />

holder and three cartridges.<br />

102<br />

www.discoverysciences.com


analytical hplc<br />

Hamilton ® Anion, Cation, and Organic Acid Columns<br />

PRP-X100 Anion Columns<br />

High pH stability makes this column ideal for the separation<br />

of weak anions. PRP TM -X100 provides excellent resolution<br />

for the seven most frequently analyzed inorganic anions.<br />

For non-suppressed analyses only.<br />

PRP-X200 Cation Analysis Columns<br />

For separation of the alkali metal and alkaline earth cations<br />

in separate runs.<br />

PRP-X300 Organic Acid Columns<br />

For separation of simple aliphatic carboxylic acids and<br />

alcohols. Inorganic anions are not retained.<br />

1<br />

EDTA in Eye Drops<br />

8068<br />

1. CuEDTA<br />

Hamilton ® PRP-X100 Specifications<br />

Composition:<br />

Trimethylammonium psDVB copolymer<br />

Particle Size:<br />

10µm, spherical<br />

Exchange Capacity: 0.19meq/g<br />

Mobile Phase Limits: pH 1–13, 0–100% organic modifier<br />

Hamilton ® PRP-X200 Specifications<br />

Composition:<br />

Sulfonated psDVB copolymer<br />

Particle Size:<br />

10µm, spherical<br />

Exchange Capacity: 0.35meq/g<br />

Mobile Phase Limits: pH 1–13, 0–100% organic modifier<br />

Hamilton ® PRP-X300 Specifications<br />

Composition:<br />

Sulfonated psDVB in H+ form<br />

Particle Size: 3µm and 7µm<br />

Mobile Phase Limits: pH 1–13, 0–100% organic modifier<br />

1<br />

2<br />

3<br />

Alkali Metals<br />

5204<br />

1. Lithium<br />

2. Sodium<br />

3. Ammonium<br />

4. Potassium<br />

5. Cesium<br />

hplc columns | ion chromatography<br />

4 5<br />

0 2 4 6 8 10 12 Min.<br />

Column: PRP-X100, 10µm, 4.1 x 150mm (Part No. 79434)<br />

Mobile Phase: 0.003N Sulfuric Acid<br />

Flow Rate: 2mL/min<br />

Detector: UV at 254nm<br />

0 1 2 3 4 5 Min.<br />

Column: PRP-X200, 10µm, 4.1 x 150mm (Part No. 79441)<br />

Mobile Phase: 0.004N HNO3 in 30% MeOH<br />

Flow Rate: 2mL/min<br />

Detector: Conductivity<br />

Hamilton ® PRP-X100 Columns<br />

Packing i.d. x Length Part No.<br />

PRP-X100 2.1 x 150mm 79348<br />

2.1 x 250mm 79346<br />

4.1 x 100mm 79439<br />

4.1 x 150mm 79434<br />

4.1 x 250mm 79433<br />

Hamilton ® PRP-X200 Columns<br />

Particle Size i.d. x Length Part No.<br />

PRP-X200 2.1 x 150mm 79394<br />

2.1 x 250mm 79347<br />

4.1 x 150mm 79441<br />

4.1 x 250mm 79442<br />

Hamilton ® PRP-X300 Columns<br />

Particle Size i.d. x Length Part No.<br />

PRP-X300, 3µm 4.1 x 150mm 79819<br />

PRP-X300, 7µm 4.1 x 150mm 79464<br />

4.1 x 250mm 79465<br />

4.6 x 150mm 79485<br />

Hamilton ® PRP-X100 Guard Kits and Cartridges<br />

Description Qty. Part No.<br />

Guard Column Starter Kit<br />

ea 79448<br />

PRP-X100, 1 Holder, 2 Cartridges<br />

Replacement Guard Cartridges<br />

(Requires Hamilton ® Guard Holder)<br />

PRP-X100, 25 x 2.3mm<br />

5 79446<br />

Hamilton ® PRP-X200 Guard Kits and Cartridges<br />

Description Qty. Part No.<br />

Guard Column Starter Kit<br />

ea 79456<br />

PRP-X200, 1 Holder, 2 Cartridges<br />

Replacement Guard Cartridges<br />

(Requires Hamilton ® Guard Holder)<br />

PRP-X200, 25 x 2.3mm<br />

5 79449<br />

Hamilton ® PRP-X300 Guard Kits and Cartridges<br />

Description Qty. Part No.<br />

Guard Column Starter Kit<br />

ea 79460<br />

PRP-X300, 1 Holder, 2 Cartridges<br />

Replacement Guard Cartridges<br />

(Requires Hamilton ® Guard Holder)<br />

PRP-X300, 25 x 2.3mm<br />

5 79453<br />

www.discoverysciences.com<br />

103


analytical hplc<br />

hplc columns | ion chromatography<br />

Alltech ® Anion<br />

Exclusion Columns<br />

• Separate organic acids and weak acid anions<br />

• Polymer-based for broad pH stability<br />

• Economical choice for small inorganics<br />

Anion Exclusion Columns separate organic acids and weakly<br />

ionized anions by an anion exclusion mechanism. Dilute<br />

mineral acids are the typical mobile phases for the separation.<br />

Acetonitrile may be used as an organic modifier to decrease<br />

the retention of hydrophobic compounds.<br />

1<br />

2<br />

Organic Acid Standards<br />

3<br />

13037<br />

1. Oxalic Acid<br />

2. Maleic Acid<br />

3. Malic Acid<br />

4. Succinic Acid<br />

5. Formic Acid<br />

6. Acetic Acid<br />

Alltech ® Transition<br />

Metal Columns<br />

• Separate divalent transition metals and metal-cyano<br />

complexes more selectively than a cation exchange<br />

column<br />

To separate divalent transition metals, use conductivity<br />

detection for concentrations as low as 1ppm, or UV detection<br />

with post-column reaction for ppb-level concentrations<br />

To separate metal-cyano complexes, use the Alltech ® low<br />

UV IPC A (Part No. 185149) as the ion-pair reagent, and<br />

methanol or acetonitrile as the organic modifier.<br />

Metal-Cyano Complexes<br />

5358<br />

4 5<br />

6 8 10 12 14 16 18 20 22 24 Min.<br />

6<br />

1<br />

2 3 4<br />

5<br />

1. Fe(CN)6 4-<br />

2. Ag(CN)2 -<br />

3. Fe(CN)6 3-<br />

4. Ni(CN)4 2-<br />

5. Au(CN)2 -<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Anion Exclusion, 10µm, 7.5 x 300mm<br />

(Part No. 269062)<br />

1.5mM Sulfuric Acid<br />

0.4mL/min<br />

Conductivity<br />

0 10 20 30 40 Min.<br />

Anion Exclusion Specifications<br />

Composition:<br />

Highly sulfonated poly (styrene-divinylbenzene)<br />

cation exchanger<br />

Particle Size: 10µm<br />

Mobile Phase Limits:


analytical hplc<br />

Alltech ® Surfactant Columns<br />

Surfactant/R IC Columns<br />

• Separate anionic and cationic surfactants<br />

• Separate short and long chain surfactants in one<br />

gradient run<br />

The Surfactant/R Column separates anionic and cationic<br />

surfactants by ion-pair chromatography along with suppressed<br />

conductivity detection. This column can also be used for other<br />

reversed-phase applications.<br />

1<br />

2<br />

3<br />

Short and Long Chain<br />

Cationic Surfactants<br />

4<br />

5<br />

6<br />

7<br />

10317<br />

1. Tetramethyl Ammonium (20ppm)<br />

2. Tetraethyl Ammonium (20ppm)<br />

3. Tetrapropyl Ammonium (20ppm)<br />

4. Tetrabutyl Ammonium (30ppm)<br />

5. Dodecyltrimethyl Ammonium (30ppm)<br />

6. Cetyltrimethyl Ammonium (40ppm)<br />

7. Myristyltrimethyl Ammonium (50ppm)<br />

Surfactant/C IC Columns<br />

• For non-suppressed analyses<br />

• Silica-based for symmetrical peak shapes<br />

Choose Surfactant C8 for short chain anionic surfactants<br />

such as alkyl sulfates and alkyl sulfonates.<br />

Choose Surfactant C18 for long chain or aromatic<br />

surfactants such as xylene sulfonate and dodecyl benzene<br />

sulfonate.<br />

1<br />

Alkyl Sulfates<br />

5998<br />

1. Octyl Sulfate<br />

2. Decyl Sulfate<br />

3. Dodecyl Sulfate<br />

hplc columns | ion chromatography<br />

0 2 4 6 8 10 12 14 16 18 20 22 Min.<br />

Column:<br />

Surfactant/R Column, 7µm, 4.6 x 150mm<br />

(Part No. 25101)<br />

Mobile Phase: A: 2mM Nonafluoropentanoic Acid<br />

B: 100% Acetonitrile<br />

Gradient: Time: 0 5 8 20<br />

%B: 30 30 35 80<br />

Flow Rate: 1.0mL/min<br />

Detector:<br />

Suppressed Conductivity<br />

2<br />

0 6 12 18 24 30 Min.<br />

3<br />

Surfactant/R Specifications<br />

Composition:<br />

Polydivinylbenzene (DVB) based resin<br />

Particle Size: 7µm<br />

Mobile Phase Limits: pH 1–14, 0–100% organic modifier<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Surfactant C8, 5µm, 4.6 x 250mm<br />

(Part No. 269072)<br />

0.02g/L Ammonium Acetate in 40% Methanol<br />

1.2mL/min<br />

Conductivity<br />

Surfactant/R Columns<br />

Packing i.d. x Length PEEK Part No. SS Part No.<br />

Surfactant/R, 7µm 4.6 x 150mm 25101 25100<br />

Guards for Surfactant/R Columns<br />

Description Qty. Part No.<br />

GRP-1 Revised Phase 3 38124<br />

All-Guard Cartridge Holder* ea 80101<br />

*Direct-Connect column coupler included.<br />

related product<br />

Save money with IC All-Guard Kits on page 98. Kit includes one<br />

holder and three cartridges.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

Surfactant/C Specifications<br />

Composition:<br />

Silica-based C8 or C18<br />

Particle Size: 5µm<br />

Mobile Phase Limits: pH 2–7, 0–100% organic modifier<br />

Surfactant/C Columns<br />

Packing i.d. x Length PEEK Part No. SS Part No.<br />

C8, 5µm 4.6 x 250mm 269072 269092<br />

C18, 5µm 4.6 x 250mm 269071 269091<br />

Guards for Surfactant/C Columns<br />

Description Qty. Part No.<br />

GRP-2 Revised Phase 3 38129<br />

All-Guard Cartridge Holder* ea 80101<br />

*Direct-Connect column coupler included.<br />

www.discoverysciences.com<br />

105


analytical hplc<br />

Custom HPLC Columns<br />

Ordering Instructions<br />

Alltech offers a large selection of packing materials and formats to create<br />

your own custom HPLC column.<br />

hplc columns | custom<br />

Step 1: Select your packing material and particle size from Table 1.<br />

Step 2: Select your column format from Table 2.<br />

Step 3: Call your local Customer Service office for a quote. Indicate phase,<br />

particle size, format, and dimensions.<br />

Table 1—HPLC Packing Materials<br />

Family Phase Particle Sizes<br />

Adsorbosphere<br />

C18, C8, CN, NH2, Silica, HS C18, HS Silica, UHS C18, Phenyl, CN-AQ, SAX, SCX, OPA HR, OPA 3, 5, 10µm<br />

HS, CN-AQ, SAX, SCX, OPA HR, OPA HS<br />

Adsorbosphere XL C18 300, C8 300, C18, C8, Silica, SAX, SCX, TMS 3, 5, 10µm<br />

Allsphere C8, CN, NH2, ODS-2, Silica, C1, ODS-1, Phenyl, C6, SAX, SCX 3, 5µm<br />

Alltima C18, C8, Silica, CN, NH2, Phenyl, C18-LL, C18-WP, C4-WP 3, 5, 10µm<br />

Alltima HP C18, C18 Amide, C18 EPS, C18 HiLoad, C8, CN, Silica 1.5, 3, 5µm<br />

Apollo C18, C8, Phenyl, Silica 5µm<br />

Brava C18 BDS, C18 ODS, C8, Phenyl, Cyano BDS, Cyano, Amino, Silica 3, 5µm<br />

Carbohydrate Anomer, NH2 10µm<br />

Econosphere C18, C8, Silica, CN, NH2 3, 5, 10µm<br />

Everest ® C18 5, 10, 15–20µm<br />

<strong>Grace</strong>Alpha C18, C8, Silica 5, 10, 15, 20µm<br />

Grom-Sil ODS-0, ODS-1, ODS-3, ODS-4, ODS-5, ODS-6, ODS-7, C8, C6, C4, C1, CN, NH2, DIOL, IEX, Silica 1.5, 3, 5, 7, 10µm<br />

Grom-Sapphire C18, C8, C4, Silica 3, 5, 10µm<br />

Ion Chromatography Transition Metal, Universal Cation, Surfactant C8, Surfactant C18, Surfactant/R, Allsep, Allsep 5, 7, 10µm<br />

A-2, Novosep A-1<br />

Kromasil ® , Akzo-Nobel C18, C4, C8, NH2, Silica 5, 10µm<br />

LiChrosorb ® , Merck NH2, RP-18, RP-8, RP-Select B, Silica-60, Silica-100 5, 10µm<br />

LiChrospher ® , Merck RP-18, RP-18 Endcapped, RP-8, RP-8 Endcapped, Silica-60, CN, Diol, NH2, Silica-100, RP-Select B 3, 5µm<br />

Macrosphere GPC 60, 100, 150, 300, SAX 300, SCX 300, WAX 300, WCX 300 5, 7µm<br />

Mixed-Mode C18/Cation, C8/Anion, C8/Cation 5, 7µm<br />

Nucleosil ® , Macherey-Nagel C18, C8, CN, NH2, SA, SB, Silica, Phenyl 3, 5, 10µm<br />

Partisil, Whatman C8, ODS-2, ODS-3, PAC, SAX, Silica, ODS, SCX 5, 10µm<br />

Platinum<br />

C18-300, EPS C18-300, Silica-300, C18, EPS C18, C8, C18, EPS C18, C8, EPS C8, CN, NH2, 1.5, 3, 5µm<br />

Phenyl, Silica, SAX<br />

Prevail Amide, Amino, C18, C18 Select, C8, CN, Phenyl, Silica 3, 5µm<br />

ProSphere HP C18 300, C18 100, C4 300 1.5, 3, 5, 10µm<br />

Spherisorb ® , Waters C8, CN, NH2, ODS-2, Silica, ODS-1, Phenyl, C6, SAX, SCX 3, 5µm<br />

Vydac ® MS C18, C8, C4, Diphenyl 3, 5, 10–15µm<br />

Vydac ® TP C18, C8, C4, Diphenyl 3, 5, 10–15µm<br />

7102a<br />

Table 2—Custom Part Numbers for HPLC Column Formats<br />

Format Custom Part No. Description Available Lengths Available i.d.s<br />

Capillary Call Quartz glass <strong>Grace</strong> capillary columns connect directly to 5, 10, 20, 50, 75, 100, 0.075, 0.1, 0.2, 0.3, 0.5, 0.8mm<br />

microinjector and via fused silical capillary detectors 150, 250mm<br />

Analytical, Solvent- C-6000 Stainless steel analytical column with industry standard 30, 50, 100, 150, 250, 2.1, 3.0, 3.9, 4.1, 4.6mm<br />

Reducer, and LC/MS<br />

female fittings.<br />

300mm<br />

Analytical, Waters ® C-6000 Stainless steel analytical column with Waters ® -style 30, 50, 100, 150, 250, 2.1, 3.0, 3.9, 4.1, 4.6mm<br />

Style Endfittings<br />

endfittings.<br />

300mm<br />

Metal-Free* C-6000 Metal-Free columns with industry standard female 30, 50, 100, 150, 250, 2.1 (30 or 100mm lengths only),<br />

fittings.*<br />

300mm<br />

4.6, 7.5mm<br />

Rocket C-6000 Fast-analysis columns with Rocket endfittings; 33, 53mm 7mm<br />

requires 3µm or smaller particle size.<br />

All-Guard Cartridges C-9800 4/pk All-Guard Cartridges, Stainless Steel. Purchase 7.5mm<br />

2.1, 3.0, 4.6mm<br />

Stainless Steel<br />

holder 80101 separately.<br />

All-Guard Cartridges C-9400 4/pk All-Guard Cartridges, PEEK. Purchase holder 7.5mm<br />

4.6mm<br />

Metal-Free*<br />

80101 separately.<br />

Preparative** C-6000F Stainless steel preparative column with threaded 70, 100, 250, 500mm 7, 10, 22mm<br />

endfittings.<br />

Capillary Guards Call Create a zero dead volume finger-tight connection to 5, 10, 20mm 0.1, 0.15, 0.3, 0.5mm<br />

capillary columns.<br />

*Metal-Free columns are available with ProSphere and Ion Chromatography packings only.<br />

**Additional custom prep columns available, see pages 162–170.<br />

more info<br />

For more information on our column formats, see page 31.<br />

106<br />

www.discoverysciences.com


analytical hplc<br />

Empty HPLC Hardware<br />

Stainless Steel Analytical Column Hardware<br />

• Threaded tube for easy assembly<br />

• Type 316 stainless steel construction<br />

• Column i.d. of 2.1, 3.2, 3.9, 4.1, and 4.6mm<br />

Endfitting<br />

Ferrule<br />

Threaded Column Tube<br />

Frit/Insert<br />

Endfitting<br />

Stainless steel analytical columns come complete with the<br />

threaded tube, two 2µm industry standard frit/inserts, and two<br />

stainless steel endfitting nuts. Removable color-coded bands<br />

available separately, (Part No. 93237). Industry standard<br />

frit/inserts contain a stop depth equal to 0.100" (see Figure 1).<br />

Optional 0.5µm porosity frit/inserts are also available.<br />

5319<br />

Compression<br />

Screw<br />

Stop Depth<br />

(0.100")<br />

Stainless Steel<br />

Analytical Column<br />

Frit/Insert<br />

Figure 1—Stainless steel analytical columns have ports with industry<br />

standard stop depth.<br />

Packing Adapter<br />

0765<br />

hplc columns | hardware<br />

Adapters and sealing rings are available for slurry packing<br />

your own columns (see Figure 2). The packing adapter<br />

comes with a 1/4" precolumn tube to connect to 1/4" slurry<br />

reservoirs.<br />

Stainless Steel Analytical Column Hardware Specifications<br />

Material:<br />

316 Stainless Steel<br />

Max. Temperature: 100ºC<br />

Max. Pressure<br />

10,000psig<br />

Thread Type:<br />

10-32 UNF (CPI Standard Ports)<br />

Typical Use:<br />

Analytical HPLC Columns<br />

Sealing Ring<br />

Figure 2—Packing adapter threads directly onto stainless steel<br />

analytical column tube.<br />

2730<br />

Stainless Steel Analytical Hardware and Accessories<br />

2.1mm i.d.<br />

3.2mm i.d.<br />

3.9mm i.d.<br />

4.1mm i.d.<br />

4.6mm i.d.<br />

Description<br />

Part No.<br />

Part No.<br />

Part No.<br />

Part No.<br />

Part No.<br />

Complete Columns<br />

50mm 65175 65170 65165 65160 65150<br />

100mm 65176 65171 65166 65161 65152<br />

150mm 65177 65172 65167 65162 65154<br />

250mm 65178 65173 65168 65163 65156<br />

300mm 65179 65174 65169 65164 65158<br />

Replacement Parts<br />

Endfitting (ea) 75001 75001 75001 75001 75001<br />

Frit/Insert, 2µm (5/pk) 75028 75026 75024 75022 75020<br />

Frit/Insert, 0.5µm (5/pk) 75029 75027 75025 75023 75021<br />

Packing Accessories<br />

Packing Adapter (ea) 65189 65188 65187 65186 65185<br />

Sealing Rings (10/pk) 65199 65198 65197 65196 65195<br />

www.discoverysciences.com<br />

107


analytical hplc<br />

hplc columns | hardware<br />

Empty HPLC Hardware<br />

Stainless Steel Preparative Column Hardware<br />

• Threaded format for easy assembly<br />

• Extended column life with the patented continuously<br />

adjustable piston (CAP)<br />

• Column i.d. of 7, 10, and 22mm<br />

The Alltech ® easy-to-use preparative format has threaded<br />

endfittings and a continuously adjustable piston/frit (CAP).<br />

The piston/frit extends column life by compressing the packed<br />

bed to remove voids.<br />

Column Tube<br />

Continuously<br />

Adjustable<br />

Piston/Frit<br />

Endfitting<br />

Stainless Steel Swaged Column Hardware<br />

• Passivated stainless steel for a more inert surface<br />

• Uses precision bore tubing and OptiFlow endfittings<br />

• Column i.d. of 2.1, 3.2, 4.6, 10, and 22.5mm<br />

Stainless steel swaged hardware uses precision bore<br />

seamless tubing and OptiFlow endfittings. It is the ideal<br />

choice when standard column lengths are not desirable—<br />

just cut to your specification. OptiFlow endfittings have a<br />

flow distributor which spreads the sample and eluant across<br />

the entire frit surface to improve peak symmetry and prevent<br />

frit blockage.<br />

2µm<br />

SS Frit<br />

Distributor<br />

Disk<br />

Endfitting<br />

Tubing<br />

Nut and<br />

Ferrule<br />

5544<br />

5568<br />

Stainless Steel Preparative Column Hardware Specifications<br />

Material:<br />

316 Stainless Steel, PEEK<br />

Max. Temperature: 100ºC<br />

Max. Pressure<br />

8000psig<br />

Thread Type:<br />

10-32 UNF (CPI Standard Ports)<br />

Typical Use:<br />

Prep HPLC Columns<br />

Precision Bore HPLC Column Tubing Specifications<br />

Material:<br />

316 Stainless Steel<br />

Max. Temperature: 500ºC<br />

Max. Pressure<br />

8000psig<br />

Typical Use:<br />

HPLC Column Assembly w/Swageable<br />

Endfittings<br />

Stainless Steel Preparative Hardware and Accessories<br />

i.d. Length Qty. Part No.<br />

Complete Columns<br />

7mm 100mm ea 96500<br />

7mm 250mm ea 96501<br />

7mm 500mm ea 96502<br />

10mm 100mm ea 96510<br />

10mm 250mm ea 96511<br />

10mm 500mm ea 96512<br />

22mm 70mm ea 96524<br />

22mm 100mm ea 96520<br />

22mm 250mm ea 96521<br />

22mm 500mm ea 96522<br />

Replacement Endfittings<br />

7mm — ea 96505<br />

10mm — ea 96515<br />

22mm — ea 96525<br />

Replacement Piston/Frit, 2µm<br />

7mm — ea 96507<br />

10mm — ea 96517<br />

22mm — ea 96527<br />

Packing Adapters*<br />

7mm — ea 96508<br />

10mm — ea 96518<br />

Packing Seals*<br />

7mm — 10 96509<br />

10mm — 10 96519<br />

*22mm packing adapters and seals are not available.<br />

Precision Bore Tubing<br />

Per Foot<br />

Part No.<br />

Per Meter<br />

Part No.<br />

o.d. x i.d.<br />

Precision Bore Tubing<br />

1/8" x 2.1mm 3012 30120<br />

1/4" x 2.1mm 3013 30130<br />

1/4" x 3.2mm 3011 30110<br />

1/4" x 4.6mm 3015 30150<br />

OptiFlow Endfittings*<br />

Description For use with Tubing i.d. Qty. Part No.<br />

OptiFlow Endfittings<br />

1/4" 2.1, 3.2, 4.6mm ea 400612<br />

3/8" 7.0mm ea 10123<br />

1/2" 10.0mm ea 9205<br />

1" 2.25mm ea 9204<br />

*Each fitting is supplied with a nut and ferrule for 1/16" tubing, a 2-micron stainless steel<br />

frit and distributor disk.<br />

related products<br />

Additional prep hardware also available. See page 150.<br />

108 www.discoverysciences.com


analytical hplc<br />

Stainless Steel Frits<br />

• Type 316 stainless steel<br />

• Heat-passivated for a more inert surface<br />

Stainless Steel Frit Specifications<br />

Material:<br />

316 Stainless Steel<br />

Max. Temperature: 500ºC<br />

Max. Pressure: 10,000psig<br />

Typical Use:<br />

Column Inlet/Outlet<br />

Stainless Steel Frits<br />

5/pk<br />

Part No.<br />

25/pk<br />

Part No.<br />

Frit Diameter Thickness Porosity<br />

1/4" (6.350mm) 0.031" (0.79mm) 0.5µm 720805 720825<br />

0.031" (0.79mm) 2.0µm 721005 721025<br />

0.063" (1.59mm) 2.0µm 716505 716525<br />

3/8" (9.525mm) 0.031" (0.79mm) 0.5µm 721205 721225<br />

0.031" (0.79mm) 2.0µm 721405 721425<br />

0.063" (1.59mm) 0.5µm 718005 718025<br />

0.063" (1.59mm) 2.0µm 718205 718225<br />

1/2" (12.7mm) 0.031" (0.79mm) 0.5µm 721605 721625<br />

0.031" (0.79mm) 2.0µm 721805 721825<br />

1" (25.4mm) 0.031" (0.79mm) 2.0µm 722205 722225<br />

0.063" (1.59mm) 2.0µm 718605 718625<br />

best<br />

value<br />

hplc columns | hardware<br />

Encased Stainless Steel Frits<br />

• Improved sealing over conventional frits<br />

• Better mechanical stability<br />

Encased Stainless Steel Frit Specifications<br />

Material:<br />

316 Stainless Steel, PEEK, or Graph-Tite<br />

Max. Temperature: 100ºC<br />

Max. Pressure: 10,000psig<br />

Typical Use:<br />

Column Inlet/Outlet<br />

Encased Stainless Steel Frits<br />

0.5 Micron<br />

(5/pk)<br />

Part No.<br />

2 Micron<br />

(5/pk)<br />

Part No.<br />

2 Micron<br />

(10/pk)<br />

Part No.<br />

2 Micron<br />

(20/pk)<br />

Part No.<br />

Frit Diameter Ring Diameter Thickness<br />

Stainless Steel Frits with PEEK Ring<br />

0.083" (2.1mm) 0.250" (6.4mm) 0.063" (1.59mm) — — 9900 99001<br />

0.125" (3.2mm) 0.250" (6.4mm) 0.063" (1.59mm) — — 9902 99021<br />

0.156" (4.0mm) 0.250" (6.4mm) 0.063" (1.59mm) — — 9906 99061<br />

0.273" (7.0mm) 0.375" (9.5mm) 0.063" (1.59mm) — — 9910 99101<br />

0.352" (10mm) 0.500" (12.7mm) 0.063" (1.59mm) — — 9912 99121<br />

Stainless Steel Frits with Carbon-Reinforced PEEK Ring<br />

0.083" (2.1mm) 0.250" (6.4mm) 0.031" (0.79mm) 75015 75014 — —<br />

0.125" (3.2mm) 0.250" (6.4mm) 0.031" (0.79mm) 75013 75012 — —<br />

0.181" (4.6mm) 0.250" (6.4mm) 0.031" (0.79mm) 75006 75005 — —<br />

Encased Metal-Free PEEK Frits<br />

• Metal-free inert construction<br />

• Ideal for chromatography biocompatibility applications<br />

Encased Metal-Free PEEK Frit Specifications<br />

Material:<br />

PEEK<br />

Max. Temperature: 100ºC<br />

Max. Pressure: 10,000psig<br />

Typical Use:<br />

Column Inlet/Outlet<br />

Encased Metal-Free PEEK Frits<br />

5 Micron<br />

(5/pk)<br />

Part No.<br />

10 Micron<br />

(5/pk)<br />

Part No.<br />

Frit Diameter Ring Diameter Thickness<br />

PEEK Frits with PEEK Ring<br />

0.125" (3.2mm) 0.250" (6.4mm) 0.063" (1.59mm) 69025 69026<br />

0.181" (4.6mm) 0.250" (6.4mm) 0.063" (1.59mm) 68152 69027<br />

0.312" (7.9mm) 0.375" (9.5mm) 0.063" (1.59mm) 67152 69028<br />

www.discoverysciences.com<br />

109


analytical hplc<br />

hplc columns | hardware<br />

Empty Low-Pressure Hardware<br />

Omnifit ® Low-Pressure Column Hardware<br />

• Borosilicate heavy wall glass with precision threaded<br />

ends and patented “strain free” endfittings<br />

• Bore diameter constant to ±0.1mm<br />

• Higher pressure limits than other low-pressure column<br />

hardware<br />

Each Omnifit ® glass column includes two PTFE end pieces<br />

(one fixed, one adjustable), two 1/4-28 polypropylene outer<br />

caps, one frit kit (two each: 10µm polyethylene, 10µm PTFE<br />

and 25µm PTFE), two flangeless tube endings, two gripper<br />

fittings, and two meters of 1/16" PTFE tubing.<br />

Polypropylene<br />

Outer Cap<br />

Adjustable<br />

End Piece<br />

O-ring<br />

Frit<br />

Glass Column<br />

Polypropylene<br />

O-ring Outer Cap<br />

Frit<br />

Fixed End<br />

Piece<br />

Omnifit ® Column Hardware Specifications<br />

Material:<br />

Borosilicate Glass, PTFE, Fluoroelastomer<br />

Polymer, Polypropylene, and Polyethylene<br />

Max. Temperature: 100ºC<br />

Max. Pressure: Varies, See Price Block<br />

Thread Type:<br />

1/4-28 UNF<br />

Typical Use:<br />

Low-pressure, Metal-free Columns<br />

2719<br />

5551<br />

Omnifit ® Glass Columns<br />

Length<br />

Part No.<br />

6.6mm i.d. Column, rated to 60Atm (900psig)<br />

100mm 62271<br />

150mm 62272<br />

250mm 62273<br />

400mm 62276<br />

10mm i.d. Column, rated to 40Atm (600psig)<br />

100mm 61110<br />

150mm 61120<br />

250mm 61140<br />

500mm 61160<br />

1000mm 61180<br />

15mm i.d. Column, rated to 20Atm (300psig)<br />

100mm 64110<br />

150mm 64120<br />

250mm 64140<br />

500mm 64160<br />

1000mm 64180<br />

25mm i.d. Column, rated to 10Atm (150psig)<br />

150mm 62121<br />

250mm 62141<br />

500mm 62161<br />

1000mm 62181<br />

related products<br />

Looking for low-pressure accessories?<br />

Low-pressure fittings, pages 117–120;<br />

Low-pressure tubing, page 387.<br />

Omnifit ® Glass Column Accessories<br />

Description Qty. Part No.<br />

6.6mm i.d. Column Accessories<br />

Adjustable Plunger ea 62287<br />

25µm Polyethylene Frits 20 62281<br />

25µm PTFE Frits 20 62282<br />

10µm PTFE Frits 20 62283<br />

5µm PTFE Frits 20 62284<br />

Fluoroelastomer Polymer O-rings 10 62285<br />

Silicone O-rings 10 62286<br />

10mm i.d. Column Accessories<br />

Adjustable Plunger ea 61651<br />

25µm Polyethylene Frits 20 61411<br />

25µm PTFE Frits 20 61421<br />

10µm PTFE Frits 20 61461<br />

5µm PTFE Frits 20 61471<br />

Fluoroelastomer Polymer O-rings 10 61661<br />

Silicone O-rings 10 61671<br />

15mm i.d. Column Accessories<br />

Adjustable Plunger ea 64651<br />

25µm Polyethylene Frits 20 64411<br />

25µm PTFE Frits 20 64421<br />

10µm PTFE Frits 20 64461<br />

5µm PTFE Frits 20 64471<br />

Fluoroelastomer Polymer O-rings 10 64661<br />

Silicone O-rings 10 64671<br />

25mm i.d. Column Accessories<br />

Adjustable Plunger ea 62651<br />

25µm Polyethylene Frits 20 62411<br />

25µm PTFE Frits 20 62421<br />

10µm PTFE Frits 20 62461<br />

5µm PTFE Frits 20 62471<br />

Fluoroelastomer Polymer O-rings 10 62661<br />

Silicone O-rings 10 62671<br />

110 www.discoverysciences.com


analytical hplc<br />

Prefilters<br />

Direct-Connect Filter Kit<br />

• Threads into column inlet for<br />

minimal dead volume<br />

• Interchangeable tips connect<br />

to all column formats<br />

• Inexpensive replaceable filter<br />

elements<br />

SofGrip<br />

Fitting<br />

Stainless Steel<br />

Filter House<br />

Tips<br />

6382<br />

In-Line Filter Kit<br />

• Available in metal-free or<br />

316 stainless steel<br />

• Comes with connecting fittings<br />

• Replaceable filter element<br />

Metal-Free<br />

In-Line Filter<br />

5557<br />

Stainless Steel<br />

In-Line Filter<br />

6610<br />

Universal Mini Filters<br />

• Low volume direct-connect design<br />

• Ideal for LC/MS applications<br />

• Depth filter for greater capacity without band spreading<br />

Rheodyne ® Column In-Line Filter Kit<br />

• Install between injector and column<br />

• Use 3mm filter kit for 4.6mm columns<br />

• Use 1.5mm filter kit for 1 and 2mm<br />

columns<br />

6679<br />

5420<br />

High-Pressure In-Line Column Prefilter<br />

• Install between injector and column<br />

• Filter has surface area of 7.1mm 2<br />

High-Capacity In-Line Filters<br />

• Place between the pump<br />

and the injector<br />

• Filter has a surface area of 2.5cm 2<br />

Prefilters<br />

Description Material Max. Temp. Max. Pressure Thread Type Porosity Qty. Part No.<br />

Direct-Connect TM Filter Kit and Replacement Parts<br />

Direct Connect Filter Kit 316 SS, PTFE, and Kel-F ® 100°C 5000psig 10-32 UNF 2.0µm ea 28689<br />

Housing 316 Stainless Steel 100°C 5000psig 10-32 UNF — ea 27005<br />

Filter Stainless Steel 100°C 5000psig 10-32 UNF 2.0µm 5/pk 28640<br />

Female Tip Kel-F ® 100°C 5000psig 10-32 UNF — ea 28002<br />

Waters ® Tip Kel-F ® 100°C 5000psig 10-32 UNF — ea 28004<br />

Valco ® Tip Kel-F ® 100°C 5000psig 10-32 UNF — ea 28006<br />

Distributor Disks PTFE 100°C 5000psig 10-32 UNF — ea 28008<br />

In-Line Filter Kit and Replacement Parts<br />

Metal-Free Filter Kit* PEEK, PAT ® , and Graph-Tite 100°C 5000psig 10-32 UNF 2.0µm ea 68250<br />

Stainless Steel Filter Kit** 316 SS and Graph-Tite 100°C 5000psig 10-32 UNF 2.0µm ea 27000<br />

Filter PAT ® 100°C 5000psig 10-32 UNF 2.0µm 5/pk 68152<br />

Filter Stainless Steel 100°C 5000psig 10-32 UNF 2.0µm 5/pk 28640<br />

Housing 316 Stainless Steel 100°C 5000psig 10-32 UNF — ea 27010<br />

Universal Mini Filters †<br />

Mini Filter 1.2µL internal volume 316 Stainless Steel 100°C 7000psig 10-32 UNF 0.5µm 5/pk 77166<br />

Mini Filter 1.2µL internal volume 316 Stainless Steel 100°C 7000psig 10-32 UNF 2.0µm 5/pk 77167<br />

Mini Filter 0.3µL internal volume 316 Stainless Steel 100°C 7000psig 10-32 UNF 1.0µm 5/pk 77168<br />

High-Pressure In-Line Column Prefilter and Replacement Parts<br />

1/16" o.d. SSI Prefilter 316 Stainless Steel 500°C 15,000psig 1/4-28 UNF 2.0µm ea 05-0148<br />

1/16" o.d. SSI Prefilter 316 Stainless Steel 500°C 15,000psig 1/4-28 UNF 0.5µm ea 05-0149<br />

1/16" o.d. Industry Std. CPI Prefilter 316 Stainless Steel 500°C 15,000psig 10-32 UNF 0.5µm ea 25-0149<br />

1/16" o.d. Waters ® Prefilter 316 Stainless Steel 500°C 15,000psig 10-32 UNF 2.0µm ea 35-0148<br />

1/16" o.d. Waters ® Prefilter 316 Stainless Steel 500°C 15,000psig 10-32 UNF 0.5µm ea 35-0149<br />

Filter Elements 316 Stainless Steel 500°C 15,000psig — 2.0µm 10/pk 05-0154<br />

Filter Elements 316 Stainless Steel 500°C 15,000psig — 0.5µm 10/pk 05-0155<br />

Rheodyne ® Column In-Line Filter Kits †† and Replacement Parts<br />

1.5mm Filter Diameter Kit 316 Stainless Steel 500°C 7000psig 10-32 UNF 0.5µm ea 7315RV<br />

3mm Filter Diameter Kit 316 Stainless Steel 500°C 7000psig 10-32 UNF 0.5µm ea 7335RV<br />

1.5mm Filter Element 316 Stainless Steel 500°C 7000psig 10-32 UNF 0.5µm ea 7315-010<br />

3mm Filter Element 316 Stainless Steel 500°C 7000psig 10-32 UNF 0.5µm ea 7335-010<br />

High-Capacity In-Line Filters and Replacement Parts<br />

SSI Filter 316 Stainless Steel 500°C 15,000psig 1/4-28 UNF 0.5µm ea 050105<br />

SSI Filter 316 Stainless Steel 500°C 15,000psig 1/4-28 UNF 2.0µm ea 050108<br />

Industry Standard CPI 316 Stainless Steel 500°C 15,000psig 10-32 UNF 0.5µm ea 250105<br />

Industry Standard CPI 316 Stainless Steel 500°C 15,000psig 10-32 UNF 2.0µm ea 250108<br />

Filter Elements 316 Stainless Steel 500°C 15,000psig — 0.5µm 2/pk 050106<br />

Filter Elements 316 Stainless Steel 500°C 15,000psig — 2.0µm 2/pk 050107<br />

*Includes PEEK holder, PAT ® filter, and two SofGrip fittings. **Includes 316 Stainless Steel holder, Stainless Steel filter, and two SofGrip fittings.<br />

†Patent #5, 525, 503; #5,730,943; #5,911,954. ††Includes one holder, one filter, three fittings, and two connecting tubes 6cm x 0.007" i.d.<br />

5561<br />

5560<br />

hplc accessories | prefilters<br />

www.discoverysciences.com<br />

111


analytical hplc<br />

hplc accessories | fittings<br />

SofGrip One-Piece<br />

High-Pressure Fittings<br />

• Soft elastomer cushion makes hand-tightening<br />

comfortable<br />

• Graph-Tite construction is three times stronger<br />

than PEEK<br />

• One-piece integrated ferrule eliminates handling<br />

small pieces<br />

• No-Slip version stays on tubing between connections<br />

SofGrip One-Piece Fitting Specifications<br />

Material:<br />

Graph-Tite (Carbon-Reinforced PEEK)<br />

Max. Temperature: 100°C<br />

Max. Pressure: 5000psig<br />

Thread Type:<br />

10-32 UNF<br />

Typical Use:<br />

1/16" o.d. Tubing Connections<br />

One-Piece High-Pressure Fittings<br />

• PEEK or Graph-Tite construction is inert and biocompatible<br />

• One-piece integrated ferrule eliminates handling small pieces<br />

• No-Slip version stays on tubing between connections<br />

best<br />

seller<br />

Other<br />

Fittings<br />

No-Slip<br />

SofGrip<br />

Integral barrel tines in No-Slip SofGrip fittings lightly grip<br />

tubing. This holds the fitting in place between connections.<br />

4615<br />

4614<br />

6361<br />

One-Piece Fitting Specifications<br />

Material:<br />

PEEK or Graph-Tite (Carbon-Reinforced PEEK)<br />

Max. Temperature: 100°C<br />

Max. Pressure: Finger-Tight: 5000psig / Wrench-Tight: 8000psig<br />

Thread Type: 10-32 UNF<br />

Typical Use: 1/16" o.d. Tubing Connections<br />

5425<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

One-Piece High-Pressure Fittings<br />

Graphic Length Color Material Qty. Standard Part No. No-Slip Part No.<br />

SofGrip One-Piece Fittings<br />

A Short Black Graph-Tite 10 40501 40511<br />

A Short Red Graph-Tite 10 40502 40512<br />

A Short Blue Graph-Tite 10 40503 40513<br />

A Short Green Graph-Tite 10 40504 40514<br />

A Short Yellow Graph-Tite 10 40505 40515<br />

B Long Black Graph-Tite 10 40506 40516<br />

A Short Assort. Graph-Tite 10 40507 40517<br />

One-Piece Fittings, Finger-Tight<br />

C Short Natural PEEK 10 32233 32293<br />

C Short Red PEEK 10 32072 32936<br />

C Short Yellow PEEK 10 32074 32935<br />

C Short Blue PEEK 10 32076 32933<br />

C Short Green PEEK 10 32078 32931<br />

C Short Black Graph-Tite 10 32343 31001<br />

C Short Assort. PEEK 12 32070 32937<br />

D Long Natural PEEK 10 32235 —<br />

D Long Black Graph-Tite 10 — 31002<br />

One-Piece Fittings, Hex-Head<br />

E Short Natural PEEK 10 32236 32297<br />

E Short Black Graph-Tite 10 32347 31003<br />

F Long Natural PEEK 10 32238 32299<br />

F Long Black Graph-Tite 10 32349 31004<br />

112 www.discoverysciences.com


analytical hplc<br />

Two-Piece High-Pressure Fittings<br />

Double-Sided Ferrule (DSF) Fittings<br />

• Double-sided ferrule (DSF) provides twice the<br />

gripping power<br />

• PEEK construction is inert and biocompatible<br />

• Economical two-piece design<br />

DSF fittings have a double-sided ferrule which grips tubing in<br />

two places. This increases the holding power and decreases<br />

the force on one area of the tubing. A unique Wrench-Tight TM<br />

and Finger-Tight design is available and combines the<br />

convenience of a Finger-Tight TM fitting with the option to<br />

wrench-tighten when higher pressures are used.<br />

Two-Piece DSF Fitting Specifications<br />

Material: PEEK or Kel-F ®<br />

Max. Temperature: 100°C<br />

Max. Pressure: Finger-Tight: 5000psig<br />

Wrench-Tight: 10,000psig<br />

Thread Type: 10-32 UNF<br />

Typical Use: 1/16" o.d. Tubing Connections<br />

A B C<br />

Two-Piece DSF Fittings<br />

Wrench-Tight/Finger-Tight<br />

Part No. (A)<br />

best<br />

value<br />

Short Hex-Head<br />

Part No. (B)<br />

Long Hex-Head<br />

Part No. (C)<br />

Color Material Qty.<br />

Two-Piece DSF Fittings<br />

Natural PEEK 10 35753 35744 35735<br />

Black PEEK 10 35077 37087 37097<br />

Replacement Ferrules (DSF)<br />

Natural PEEK 10 35740 35740 35740<br />

Natural Kel-F ® 5 32025 32025 32025<br />

hplc accessories | fittings<br />

Wing-Nut Fittings<br />

• “Wing-Nut” provides Finger-Tight operation to 6000psig<br />

• Easier to make and break connections by hand<br />

• Economical two-piece design<br />

• PEEK or Graph-Tite construction is inert and<br />

biocompatible<br />

Two-Piece Wing-Nut Fitting Specifications<br />

Material:<br />

PEEK or Graph-Tite (Carbon-Reinforced PEEK)<br />

Max. Temperature: 100°C<br />

Max. Pressure: 6000psig<br />

Thread Type: 10-32 UNF<br />

Typical Use: 1/16" o.d. Tubing Connections<br />

A<br />

Two-Piece Wing-Nut Fittings<br />

Graphic Color Material Qty. Part No.<br />

Two-Piece Wing-Nut Fittings with Ferrules<br />

A Black Graph-Tite † 10 32327<br />

B Natural PEEK 10 32326<br />

Replacement Ferrules<br />

C PEEK Ferrules PEEK 10 32335<br />

†Carbon-reinforced PEEK.<br />

B<br />

C<br />

Stainless Steel Hex-Head and Finger-Tight Fittings<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

H<br />

Stainless Steel Two-Piece Hex-Head Fitting Specifications<br />

Material:<br />

300 Stainless Steel<br />

Max. Temperature: 500°C<br />

Max. Pressure: 10,000psig<br />

Thread Type: 10-32 UNF for 1/16", 6-32 UNF for 1/32"<br />

Typical Use: 1/16" and 1/32" o.d. Tubing Connections<br />

Stainless Steel Two-Piece Finger-Tight Fitting Specifications<br />

Material:<br />

300 Stainless Steel and PEEK<br />

Max. Temperature: 100°C<br />

Max. Pressure: 7000psig<br />

Thread Type: 10-32 UNF<br />

Typical Use: 1/16" o.d. Tubing Connections<br />

Stainless Steel Two-Piece Fittings<br />

Graphic Description Length Qty. Part No.<br />

Stainless Steel Two-Piece Hex-Head Fittings<br />

A 1/16" Nut Short 5 206085<br />

B 1/16" Nut Long 5 286335<br />

C 1/16" Nut Extra-Long 5 306141<br />

— 1/32" Nut Short 10 306101<br />

D 1/16" Female Nut — 5 321355<br />

Ferrules<br />

E 1/16" — 5 286075<br />

— 1/32" — 10 30640<br />

Stainless Steel Two-Piece Finger-Tight Fittings<br />

F 1/16" Nut Short 5 321185<br />

G 1/16" Nut Long 5 321025<br />

Ferrule<br />

H PEEK, 1/16" — 5 321805<br />

www.discoverysciences.com<br />

113


analytical hplc<br />

Valco ® High-Pressure Fittings<br />

Valco ® Fitting Specifications<br />

Material:<br />

316 Stainless Steel, PEEK, or PTFE<br />

Max. Temperature: 500ºC (SS)<br />

100ºC (PEEK and PTFE)<br />

Max. Pressure: 10,000psig (SS),<br />

8000psig (PEEK and PTFE)<br />

Typical Use: High-Pressure Tubing Connections<br />

hplc accessories | fittings<br />

Valco ® Nuts and Ferrules<br />

5431 5697 5698 5549<br />

A B C<br />

Valco ® Nuts and Ferrules<br />

Graphic Description Qty. Part No.<br />

Stainless Steel Nuts<br />

A 1/32" Nut 10 306101<br />

A 1/16" Nut 10 306121<br />

A 1/8" Nut 10 306151<br />

Stainless Steel Ferrules<br />

B 1/32" (Type 303) 10 30640<br />

B 1/16" (Type 316) 10 30646<br />

B 1/8" (Type 316) 10 30647<br />

PEEK Ferrules<br />

C 1/16" 10 30661<br />

C 1/8" 10 30662<br />

PTFE Ferrules<br />

D 1/16" 10 30671<br />

D 1/8" 10 30672<br />

Valco ® Tees and Crosses<br />

E<br />

5522 5523<br />

Valco ® Tees and Crosses<br />

Graphic Size Bore Part No.<br />

Tees<br />

E 1/32" 0.25mm 30770<br />

E 1/16" 0.25mm 30771<br />

E 1/8" 0.75mm 30773<br />

E 1/8" 2.0mm 30774<br />

Crosses<br />

F 1/32" 0.25mm 30780<br />

F 1/16" 0.75mm 30782<br />

F<br />

D<br />

Valco ® Unions<br />

G<br />

J<br />

5511 5512<br />

I<br />

5520<br />

5521 5550<br />

Valco ® Unions<br />

Graphic Size Bore Part No.<br />

Internal Unions<br />

G 1/16" 0.25mm 30713<br />

G 1/16" 0.50mm 30714<br />

G 1/16" 0.75mm 30715<br />

G 1/16" 1/16" 45835<br />

G 1/8" 2.0mm 30718<br />

G 1/8" 1/8" 30719<br />

External Unions<br />

H 1/8" 2.0mm 30731<br />

Internal Reducing Unions<br />

I 1/16" to 1/32" 0.25mm 30740<br />

I 1/8" to 1/16" 0.25mm 30746<br />

I 1/8" to 1/16" 0.75mm 45850<br />

I 1/4" to 1/8" 1/8" 30755<br />

External/Internal Reducing Unions<br />

J 1/8" to 1/16" 1/16" 30761<br />

J 1/4" to 1/8" 2.0mm 30765<br />

J 1/4" to 1/8" 1/8" 30766<br />

Column Endfittings<br />

K 1/4" to 1/16" 2.1mm 45905<br />

K 1/4" to 1/16" 3.0mm 45907<br />

related products<br />

Looking for stainless<br />

steel tubing?<br />

See pages 386 and 388.<br />

H<br />

K<br />

5562<br />

114 www.discoverysciences.com


analytical hplc<br />

High-Pressure Adapters<br />

Universal Direct-Connect Column Coupler<br />

The Universal Direct-Connect Column Coupler will join any<br />

two columns, regardless of fitting type. A 10-32 threaded body<br />

accepts any of the three Kel-F ® tips on either side. Select the<br />

correct tip to join columns of any fitting type.<br />

Waters ® Tip<br />

Female Tip<br />

Valco ® Tip<br />

Universal Direct-Connect Column Couplers<br />

Graphic Description Color Part No.<br />

Universal Direct-Connect Column Coupler<br />

A Universal Type* — 28638<br />

Replacement Kel-F ® Tips<br />

B Waters ® (“C”) Red 28004<br />

B Female (“B”) Black 28002<br />

B Valco ® Blue 28006<br />

*Includes one stainless steel body, two Waters ® tips, and two ferrule tips.<br />

Universal Direct-Connect Column Adapter<br />

• Double-sided adapter works with male or female<br />

10-32 fittings<br />

• Polymeric ferrule insert adjusts to any stop depth<br />

• Seals Finger-Tight to 5000psig<br />

• Inert PEEK or Graph-Tite ferrule insert<br />

Graph-Tite<br />

ferrule insert<br />

Stainless Steel<br />

Body<br />

A<br />

Waters ® Tip<br />

Female Tip<br />

Valco ® Tip<br />

B<br />

Universal One-Piece Coupler<br />

Universal one-piece column couplers adapt to the stop depth<br />

of any 10-32 port. Each side of these PEEK couplers adjusts<br />

and bottoms out in the port to ensure that minimal dead<br />

volume is created.<br />

Color-coded sleeve<br />

indicates i.d.<br />

One-Piece Couplers<br />

One-Piece PEEK Couplers have a<br />

non-wetted color-coded Delrin ® handle.<br />

Stop depth of the tip is fixed, and<br />

provides a reliable connection when<br />

used with matching port configurations.<br />

best<br />

seller<br />

Universal One-Piece Coupler<br />

Description Color Part No.<br />

0.005" i.d. Red 336501<br />

0.007" i.d. Yellow 336502<br />

0.009" i.d. Blue 336503<br />

0.020" i.d. Orange 336504<br />

6362<br />

best<br />

value<br />

One-Piece Column Couplers<br />

Port Configuration Color Part No.<br />

Female Black 28191<br />

Waters ® Red 28192<br />

Male Red 28193<br />

Valco ® Blue 28194<br />

Female to Waters ® — 28196<br />

5441<br />

hplc accessories | fittings<br />

PEEK<br />

ferrule insert<br />

5428<br />

Column Coupler Kits<br />

Connect to<br />

female port<br />

Connect to<br />

male port<br />

Stainless Steel<br />

5442<br />

1706b<br />

Flip adapter around to accommodate any 10-32 fitting.<br />

Universal Direct-Connect Column Adapter<br />

PEEK<br />

Part No.<br />

Graph-Tite<br />

Part No.<br />

Description<br />

Universal Direct-Connect Column Adapter 29242 29246<br />

Replacement Inserts 292405 29247<br />

Universal Adapter Kit* 29244 29248<br />

*Includes two adapters and four inserts.<br />

PEEK<br />

Column Coupler Kits*<br />

Description<br />

Part No.<br />

Stainless Steel 9549<br />

PEEK 9614<br />

*Includes two 10-32 UNF fittings, two ferrules, and a 5cm 1/16" o.d. x 0.010" i.d. tube.<br />

5856<br />

www.discoverysciences.com<br />

115


analytical hplc<br />

High-Pressure Adapters, Plugs, and Caps<br />

Stainless Steel Adapters, Plugs, and Caps<br />

Polymeric Adapters, Plugs, and Caps<br />

Stainless Steel Adapters, Plugs, and Caps Specifications<br />

Material:<br />

300 Stainless Steel<br />

Max. Temperature: 500°C<br />

Max. Pressure:<br />

Thread Type:<br />

Typical Use:<br />

10,000psig with Stainless Steel Ferrules<br />

10-32 UNF<br />

1/16" o.d. Tubing<br />

Polymeric Adapters, Plugs, and Caps Specifications<br />

Material:<br />

PEEK, Delrin ® , Nylon<br />

Maximum Temperature: 100°C<br />

Maximum Pressure:<br />

Thread Type:<br />

Typical Use:<br />

8000psig<br />

10-32 UNF<br />

1/16" o.d. Tubing<br />

hplc accessories | fittings<br />

A<br />

C<br />

5476 5477<br />

5478 6287<br />

B<br />

D<br />

B<br />

A<br />

5483<br />

5484 5485<br />

C<br />

5479<br />

E<br />

5480<br />

5486<br />

F<br />

D<br />

5470 5471 5472<br />

G H I<br />

E<br />

5482 5481<br />

F<br />

Stainless Steel Adapters, Plugs, and Caps<br />

Graphic Description Bore Qty. Part No.<br />

Stainless Steel Adapters<br />

— Union, Female 0.003" ea 77450<br />

A Union, Female 0.012" ea 28627<br />

A Union, Waters 0.012" ea 97332<br />

B Union, Male 0.067" ea 10061<br />

C Union, Male to Female 0.067" ea 28609<br />

D Union, Female, Finger-Tight TM * 0.013" ea 32110<br />

E Bulkhead Union — ea 31505<br />

F Tee — ea 28629<br />

Stainless Steel Plugs<br />

G Standard (7000psig) — ea 30631<br />

H High-Pressure (10,000psig) — ea 30636<br />

Stainless Steel Cap<br />

I Standard — ea 30606<br />

*Finger-Tight TM union has PEEK ferrule, maximum pressure 8000psig, maximum<br />

temperature 100ºC.<br />

Polymeric Adapters, Plugs, and Caps<br />

Graphic Description Bore Qty. Part No.<br />

PEEK Adapters<br />

A Union 0.010" ea 32141<br />

B Tee 0.010" ea 32143<br />

C Cross 0.010" ea 32145<br />

D Bulkhead Union — ea 31504<br />

Delrin ® Plugs<br />

E Blue — 10 8872<br />

E Black — 10 18873<br />

E White — 10 18874<br />

E Red — 10 18875<br />

E Yellow — 10 18876<br />

E Green — 10 18877<br />

Nylon Caps<br />

F White — 10 8870<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

116 www.discoverysciences.com


analytical hplc<br />

High- and Low-Pressure Fittings<br />

Flange-Free Low-Pressure Fittings †<br />

• Convenient ferrule eliminates need for flanging<br />

• Compatible with all 1/4-28 UNF ports<br />

The Flange-Free system makes connections to 1/4-28,<br />

flat-bottomed ports without flanging tools. Hand-tightened<br />

connections produce a leak-free seal to 500psig on 1/8" o.d.<br />

PTFE tubing and to 1000psig on 1/16" o.d. PTFE tubing.<br />

Hex-head fittings are available for use with harder tubing,<br />

such as PEEK, Tefzel ® , or metal.<br />

†<br />

U.S. Patent #4,690,437.<br />

Flange-Free Fitting Specifications<br />

Material:<br />

Varies, See Price Block<br />

Maximum Temperature: 100°C<br />

Maximum Pressure: 1/8" 500psig<br />

1/16" 1000psig<br />

Thread Type:<br />

1/4-28 UNF<br />

Typical Use:<br />

1/16" or 1/8" o.d. Tubing Connection<br />

A<br />

5488 5489 5490<br />

B<br />

C<br />

Flanged Tubing Low-Pressure Fittings<br />

• Use with 1/8" or 1/16" flanged tubing<br />

• Easily tighten without a tool<br />

Flanged Tubing Fitting Specifications<br />

Material:<br />

PEEK with Stainless Steel Washers<br />

Maximum Temperature: 100°C<br />

Maximum Pressure: Limited by Tubing Strength<br />

Thread Type:<br />

1/4-28 UNF<br />

Typical Use:<br />

Low-Pressure Plumbing<br />

A—Finger-Tight<br />

Flanged Tubing Fittings, 10/pk<br />

5542 5543<br />

B—Washers<br />

1/16"<br />

Part No.<br />

1/8"<br />

Part No.<br />

Graphic Description Material<br />

Flanged Tubing Fittings (washer included)<br />

A Natural PEEK 37165 37175<br />

Replacement Washers<br />

B 316 SS SS 20067 20068<br />

hplc accessories | fittings<br />

Flange-Free Fittings, 10/pk<br />

1/16" o.d. Tubing<br />

Part No.<br />

1/8" o.d. Tubing<br />

Part No.<br />

Graphic Description Material<br />

Finger-Tight Nuts<br />

A White Delrin ® 201101 201201<br />

A Black Delrin ® 201122 201211<br />

A White, Long Delrin ® 201131 201221<br />

A Black, Long Delrin ® 201141 201231<br />

A Natural PEEK 37065 37075<br />

Hex-Head Nuts<br />

B Aluminum Metal 200911 200901<br />

B Stainless Steel Metal 200936 200926<br />

Flange-Free Ferrules<br />

C Ferrules PEEK 201171 201271<br />

C 0.3mm Bore Kel-F ® 200771 —<br />

C 0.8mm Bore Kel-F ® 200781 —<br />

C Ferrules Kel-F ® 201152 201251<br />

C Ferrules Tefzel ® 20240 20242<br />

Flange-Free Plus High-Pressure Fittings<br />

• Seals Finger-Tight to 5000psig<br />

• Connects to any standard 1/4-28 port<br />

• Available only for 1/16" tubing<br />

Flange-Free Plus Fitting Specifications<br />

Material:<br />

PEEK and Stainless Steel<br />

Maximum Temperature: 100°C<br />

Maximum Pressure: 5000psig<br />

Thread Type:<br />

1/4-28 UNF<br />

Typical Use:<br />

1/16" o.d. Tubing Connection<br />

Flange-Free Plus Fittings<br />

Description Qty. Part No.<br />

Fitting System* 10 25020<br />

Replacement Parts<br />

Stainless Steel Bushings 10 25022<br />

PEEK Ferrules 10 25021<br />

*Includes 10 each of fittings, bushings, and ferrules.<br />

6260<br />

Pre-Flanged PTFE Tubing<br />

• Chemically inert<br />

• Supplied with 1/4-28 nylon fittings flanged in place<br />

Pre-Flanged PTFE Tubing Specifications<br />

Material:<br />

PTFE<br />

Maximum Temperature: 100°C<br />

Maximum Pressure: 0.020" i.d., 1200psig<br />

0.030" i.d., 900psig<br />

0.063" i.d., 400psig<br />

0.100" i.d., 300psig<br />

Typical Use:<br />

Low-Pressure Plumbing<br />

Pre-Flanged PTFE Tubing, ea<br />

Length o.d. i.d. Part No.<br />

5cm 1/16" 0.030" 20013<br />

1/8" 0.063" 20012<br />

10cm 1/16" 0.030" 20015<br />

1/8" 0.063" 20014<br />

25cm 1/16" 0.030" 20017<br />

1/8" 0.063" 20016<br />

50cm 1/16" 0.030" 20027<br />

1/8" 0.063" 20018<br />

100cm 1/16" 0.030" 20043<br />

1/8" 0.063" 20020<br />

5539<br />

www.discoverysciences.com<br />

117


analytical hplc<br />

High- and Low-Pressure Adapters<br />

PEEK Port Adapters<br />

INTERNAL PORT TYPE<br />

CPI Standard (“B”) Waters ® (“C”) 1/4-28 UNF M6<br />

1 2 3<br />

4<br />

hplc accessories | fittings<br />

EXTERNAL THREAD TYPE<br />

CPI Standard<br />

(“B”)<br />

Waters ®<br />

(“C”)<br />

M6 1/4-28 UNF<br />

A<br />

B<br />

C<br />

D<br />

Part No. 32013<br />

Part No. 32015 Part No. 32022<br />

Part No. 32023<br />

Part No. 32016<br />

Part No. 32065<br />

Part No. 32066<br />

Part No. 32067<br />

Part No. 32014<br />

Part No. 32017 Part No. 32024<br />

PEEK Port Adapters<br />

Graphic<br />

Coordinate<br />

External<br />

Thread Type<br />

Internal<br />

Port Type<br />

Part No.<br />

A2 CPI Standard Waters ® Style 32015<br />

A3 CPI Standard 1/4-28 UNF 32022<br />

A4 CPI Standard M6 32065<br />

B3 Waters ® Style 1/4-28 UNF 32023<br />

B4 Waters ® Style M6 32066<br />

PEEK Port Adapters (continued)<br />

Graphic<br />

Coordinate<br />

External<br />

Thread Type<br />

Internal<br />

Port Type<br />

Part No.<br />

C1 1/4-28 UNF CPI Standard 32013<br />

C2 1/4-28 UNF Waters ® Style 32016<br />

C4 1/4-28 UNF M6 32067<br />

D1 M6 CPI Standard 32014<br />

D2 M6 Waters ® Style 32017<br />

D3 M6 1/4-28 UNF 32024<br />

PEEK Luer Adapters<br />

CPI Standard (“B”) 1/4-28 UNF M6<br />

1 2 3<br />

INTERNAL PORT TYPE<br />

LUER TYPE<br />

Male Female<br />

E<br />

F<br />

Part No. 20132 Part No. 20136<br />

Part No. 20138<br />

Part No. 20133<br />

Part No. 20137 Part No. 20139<br />

PEEK Luer Adapters<br />

Graphic<br />

Coordinate Luer Type<br />

Internal<br />

Port Type<br />

Part No.<br />

E1 Female Luer 10-32 Female 20132<br />

E2 Female Luer 1/4-28 Female 20136<br />

E3 Female Luer M6 Female 20138<br />

PEEK Luer Adapters (continued)<br />

Graphic<br />

Coordinate Luer Type<br />

Internal<br />

Port Type<br />

Part No.<br />

F1 Male Luer 10-32 Female 20133<br />

F2 Male Luer 1/4-28 Female 20137<br />

F3 Male Luer M6 Female 20139<br />

118 www.discoverysciences.com


analytical hplc<br />

Low-Pressure Adapters and Plugs<br />

• Chemically inert<br />

• 1/4-28 threaded ports<br />

• For use with Flange-Free or flanged fittings<br />

A<br />

5456 5457<br />

B<br />

Low-Pressure Adapters and Plugs Specifications<br />

Material:<br />

Varies, See Price Block<br />

Maximum Temperature: 100°C<br />

Maximum Pressure: Limited by Fittings<br />

Thread Type:<br />

1/4-28 UNF<br />

1/4-28 Low-Pressure Adapters and Plugs<br />

Graphic Description Material Qty. Part No.<br />

Unions<br />

A Union PEEK ea <strong>2008</strong>8<br />

B Bulkhead Union PEEK ea 31506<br />

C Waters ® Pump Tubing Union † PEEK ea 590110<br />

Tees<br />

D 0.8mm Bore Tee PEEK ea 20058<br />

D 1.5mm Bore Tee PEEK ea 20023<br />

Crosses<br />

E 0.8mm Bore Cross PEEK ea 20059<br />

E 1.5mm Bore Cross PEEK ea 20025<br />

Male 1/4-28 Adapters<br />

F Male 1/4-28 to Male Luer Tefzel ® ea 20019<br />

G Male 1/4-28 to Female Luer Tefzel ® ea 20055<br />

H Male 1/4-28 to Slip-Fit* PEEK ea 28848<br />

I Male 1/4-28 to 1/4" o.d. Tube SS ea 20021<br />

J Male 1/4-28 to 1/8" o.d. Tube SS ea 20056<br />

K Male 1/4-28 to Female 10-32 PEEK 2 32261<br />

Female 1/4-28 Adapters<br />

L Female 1/4-28 to 1/8" MPT Brass ea 20053<br />

M Female 1/4-28 to Female 10-32 SS ea 20041<br />

N Female 1/4-28 to Male 10-32 SS ea 20057<br />

O Female 1/4-28 to Female 10-32 PEEK 2 32262<br />

P Female M6 to Female 10-32 PEEK ea 32264<br />

Plugs<br />

Q Natural PEEK 10 37185<br />

Q Black PEEK 10 37187<br />

R White Nylon 5 20050<br />

R White Kel-F ® 5 <strong>2008</strong>9<br />

*Slip-Fit fits 1/16" to 5/32" i.d. tubing.<br />

†Slip-Fit Waters ® pump tubing to left side of union, and connect standard 1/8" or 1/16"<br />

o.d. tubing to right side of union.<br />

D<br />

6292<br />

5813 5814<br />

5445 5734 5448<br />

I<br />

5451<br />

C<br />

F G H<br />

5452<br />

5733 5447 5453<br />

K<br />

L<br />

M<br />

J<br />

E<br />

hplc accessories | fittings<br />

5454 5455 5455<br />

N O P<br />

Q<br />

5460 5444<br />

R<br />

www.discoverysciences.com<br />

119


analytical hplc<br />

hplc accessories | fittings<br />

Low-Pressure Accessories<br />

Easy-Flange Tool<br />

• Uses mechanical force to form flanges—no electricity<br />

or heat required<br />

• Forms perfect flanges on 1/16" to 1/8" o.d. PTFE or<br />

thin-walled PEEK tubing<br />

• Completely portable—use it anywhere in your lab<br />

Using mechanical force (no electricity or heat required),<br />

Easy-Flange forms perfect flanges on any PTFE tubing<br />

with an o.d. between 1/16" and 1/8" or thin walled (0.015"<br />

maximum wall thickness) PEEK tubing. Simply cut the tubing<br />

to the desired length, place a fitting on the tubing, slide the<br />

tubing into the Easy-Flange body, and form the flange using<br />

the flange-rolling tool. The entire operation takes just seconds<br />

and produces flanges with superior sealing characteristics<br />

compared to flanges formed by conventional heat methods.<br />

Low-Pressure In-Line Quick Connect<br />

• Make and break 1/16" or 1/8" tubing connections quickly<br />

and easily<br />

• Eliminate wear and tear on fittings and ferrules<br />

• Highly inert PEEK construction<br />

The Alltech ® Low-Pressure In-Line Quick Connect allows<br />

fast, effortless connection of 1/16" or 1/8" tubing where<br />

1/4-28 fittings are used. Made from high quality PEEK,<br />

the quick connect withstands repetitive connections<br />

and is compatible with a wide range of solvents. The 1/16"<br />

quick connect withstands pressures up to 1000psig, and 1/8"<br />

quick connect withstands pressures up to 500psig.<br />

Quick Connect<br />

5526<br />

6156<br />

Easy-Flange Tool<br />

Description<br />

Part No.<br />

Easy-Flange Flanging Tool* 35900<br />

Replacement Parts<br />

1.5mm Pin (Polymer) 35905<br />

1.3mm Pin (Polymer) 35906<br />

1.3mm Pin (Titanium) 35910<br />

1.0mm Pin (Polymer) 35909<br />

0.8mm Pin (Polymer) 35907<br />

0.5mm Pin (Titanium) 35908<br />

0.8mm Pin (Titanium) 35920<br />

Clean-Cut Tubing Cutter 35902<br />

Replacement Blade (for Part No. 35902) 35903<br />

*Includes: Clean-Cut tubing cutter and insert disks 35908, 35907, 35906,<br />

35910, 35920.<br />

Suggested Quick Connect Usage:<br />

• Perfect for plumbing low- and medium-pressure<br />

LC systems<br />

• Use with any low-pressure switching valve<br />

• Quickly swap mobile phase bottles from LC system<br />

or filtration equipment<br />

• Make and break connections to an online degasser<br />

Low-Pressure In-Line Quick Connect<br />

Description<br />

Part No.<br />

1/16" Quick Connect 77301<br />

1/8" Quick Connect 77302<br />

related product<br />

Looking for low-pressure tubing?<br />

See page 387.<br />

related product<br />

Looking for low-pressure 1/4-28 fittings?<br />

See page 117 for Flange-Free fittings. See page 117 for flanged<br />

fittings.<br />

5531<br />

120 www.discoverysciences.com


analytical hplc<br />

Fitting and Accessory Kits<br />

Basic Start-Up Package<br />

Provides the essential products for HPLC system start-up.<br />

No frills and no unnecessary cost.<br />

best<br />

value<br />

Advanced Start-Up Package<br />

Keeps your HPLC consumables stocked for some time with<br />

products that maximize system and lab efficiency.<br />

best<br />

value<br />

Basic Start-Up Package<br />

Description Material Qty. Part No.<br />

Basic Start-Up Package — 1 97817<br />

Replacement Individual Components<br />

Short Hex-Head Nuts/Ferrules PEEK 10 35744<br />

Long Hex-Head Nuts/Ferrules PEEK 10 35735<br />

Short Finger-Tight One-Piece* PEEK 12 32070<br />

1/8" Flange-Free Nuts PEEK 10 37075<br />

1/8" Flange-Free Ferrules Tefzel® 10 20242<br />

1/16" x 0.020" i.d. Tubing PEEK 10ft 35708<br />

1/16" x 0.007" i.d. Tubing PEEK 10ft 35712<br />

1/8" x 0.063" i.d. Tubing TFE 10ft 20063<br />

Plastic Tubing Cutter — 1 3206<br />

Replacement Blade — 1 3214<br />

10µm Solvent Inlet Filter SS 2 28870<br />

20µL Sample Loop PEEK 1 32195<br />

Open-End Wrench, 1/4" x 5/16" — 1 1998<br />

Union PEEK 1 32141<br />

6283<br />

Advanced Start-Up Package<br />

Description Material Qty. Part No.<br />

Advanced Start-Up Package — 1 97818<br />

Replacement Individual Components<br />

Short Hex-Head Nuts/Ferrules PEEK 10 35744<br />

Long Hex-Head Nuts/Ferrules PEEK 10 35735<br />

Short Finger-Tight No-Slip TM Fitting* PEEK 24 32937<br />

Long Finger-Tight No-Slip TM Fitting PEEK 10 32295<br />

1/8" Flange-Free Nuts PEEK 10 37075<br />

1/8" Flange-Free Ferrules Kel-F ® 10 201251<br />

1/16" x 0.020" i.d. Tubing PEEK 20ft 35708<br />

1/16" x 0.005" i.d. Tubing PEEK 20ft 35714<br />

1/8" x 0.063" i.d. Tubing TFE 10ft 20063<br />

Clean-Cut Tubing Cutter — 1 35902<br />

Replacement Blade — 2 35903<br />

10µm Last-Drop Inlet Filter PAT ® 2 28839<br />

In-Line Filter, 2µm PAT ® 1 68250<br />

Replacement Filter Elements PAT ® 5 68152<br />

20µL Flex-Connect Sample Loop PEEK 1 32195<br />

100µL Flex-Connect Sample Loop PEEK 1 32204<br />

Handy-Lok Fitting Wrench — 1 35751<br />

Open-End Wrench, 1/4" x 5/16" — 1 1998<br />

Union PEEK 2 32141<br />

*Assorted Colors<br />

6282<br />

hplc accessories | fittings<br />

related products<br />

Accessories for your system. <strong>Grace</strong><br />

has an assortment of Accessories<br />

Quick Reference guides available for<br />

many popular instruments.<br />

• Waters ® Alliance ®<br />

System Accessories<br />

– Request M202<br />

• Agilent 1100 and 1200<br />

System Accessories<br />

– Request M203<br />

• Waters ® Acquity UPLC ®<br />

System Accessories<br />

– Request M204<br />

www.discoverysciences.com<br />

121


analytical hplc<br />

Alltech ® Fitting Kits<br />

• Find all common accessories in one convenient kit<br />

• Fittings to match your HPLC system<br />

• Includes both high- and low-pressure fittings<br />

Alltech ® Fitting Kits provide all the necessary HPLC<br />

accessories conveniently stored in one place. You will always<br />

find what you need to keep your system running. The chart<br />

lets you determine how many of each product are included in<br />

each systems fitting kits.<br />

hplc accessories | fittings<br />

Fittings Kits<br />

Beckman<br />

97137<br />

PerkinElmer ®<br />

97148<br />

Rheodyne ® *<br />

97130<br />

Shimadzu ® *<br />

97151<br />

Universal<br />

97145<br />

System Components Part No. Material<br />

Nuts<br />

Universal SS Male Nut 206085 316 SS 15 5 4 10 5 —<br />

Two-Piece Finger-Tight 32310 PEEK 2 2 2 2 — 2<br />

Universal Wrench-Tight/Finger-Tight 35754 PEEK 5 5 4 5 15 5<br />

1/16” Flange-Free (1/4-28) 201101 Delrin ® 6 6 6 — — 6<br />

Long Universal SS Male Nut 28633 316 SS — — 10 — — 10<br />

One-Piece Fitting 32232 PEEK — — — — 2 —<br />

Long Finger-Tight One-Piece 32234 PEEK — — — 2 — —<br />

Standard Wrench-Tight/Finger-Tight 35752 PEEK — — — 4 — —<br />

Ferrules<br />

Universal SS Ferrule 286075 316 SS 20 10 4 10 10 20<br />

Ferrule for Two-Piece Finger-Tight 32322 PEEK 4 4 2 4 — 4<br />

Double-Sided Ferrule 35730 PEEK 10 10 10 10 30 10<br />

1/16” Flange-Free Ferrule 201152 Kel-F ® 6 6 — — — 6<br />

Plugs<br />

10-32 Plug 8872 Delrin ® 2 2 — 2 — 2<br />

SSI Products<br />

Nut 01-0140 316 SS — 4 5 — — —<br />

Ferrule 01-0142 316 SS — 4 5 — — —<br />

Rheodyne ® Products<br />

Bushing 77510 316 SS — 4 4 4 — —<br />

Long Bushing 77512 316 SS — 2 2 4 — —<br />

Extra-long Bushing 77519 316 SS — 2 2 10 — —<br />

Ferrule 77511 316 SS — 10 10 10 — —<br />

Unions<br />

PEEK Female Union 32141 PEEK 1 1 3 1 3 —<br />

SS Male Union 10061 316 SS — — 1 — 1 —<br />

Waters ® Female Union 97332 316 SS — — — — — 1<br />

Adapters<br />

Universal Column Adapter 29242 PEEK/SS — — — — 1 —<br />

Tubing, EDM-Cut<br />

0.010” i.d. x 5cm 97045 316 SS 5 5 5 5 5 5<br />

0.010” i.d. x 10cm 97055 316 SS 5 5 5 5 5 5<br />

0.010” i.d. x 20cm 97060 316 SS 5 5 5 5 5 5<br />

0.020” i.d. x 5cm 97075 316 SS 5 5 5 5 5 5<br />

0.020” i.d. x 10cm 97080 316 SS 5 5 5 5 5 5<br />

0.020” i.d. x 20cm 97085 316 SS 5 5 5 5 5 5<br />

*Can also be used for Spectra-Physics ® .<br />

Waters ®<br />

97155<br />

6261<br />

122 www.discoverysciences.com


analytical hplc<br />

Mobile Phase Inlet Filters<br />

Cup-Style Inlet Filters<br />

• Disposable filters and reusable PTFE sleeve for<br />

long-term savings<br />

• Uses all the mobile phase in the reservoir<br />

Cup Filters use all the mobile phase in the reservoir without<br />

drawing air into the system. A replaceable stainless steel filter<br />

cup provides the same high surface area of conventional<br />

mobile phase filters. But unlike conventional filters, a PTFE<br />

sleeve fits over the cup filter so mobile phase is drawn from<br />

the bottom of the bottle.<br />

Cup-Style Inlet Filter Specifications<br />

Material:<br />

PEEK, PTFE, 316 Stainless Steel<br />

Porosity: 2µm or 10µm<br />

Max. Temperature: 100°C<br />

Plumbing:<br />

Slip Fit to 1.5, 2.2, or 3.0mm i.d. Tubing<br />

Uni-Fit Slip fits to<br />

1.5, 2.2, or 3.0mm i.d.<br />

Tubing<br />

Replaceable Stainless<br />

Steel Cup Filter<br />

Reusable<br />

PTFE Sleeve<br />

6265<br />

Economy Inlet Filters<br />

• Flat bottom design draws all solvent from the reservoir<br />

• Economical style means economical price<br />

Economy Filters have 22mm stainless steel filter that sits<br />

on the bottom of the mobile phase reservoir drawing in all but<br />

a few milliliters of mobile phase. The heavy PTFE housing<br />

acts as a “sinker“ and has a 1/8" port to push tubing securely<br />

in place.<br />

Economy Inlet Filter Specifications<br />

Material:<br />

PTFE, Stainless Steel<br />

Porosity: 2µm or 10µm<br />

Max. Temperature: 100°C<br />

Plumbing:<br />

Push Fit for 1/8" o.d. Tubing<br />

hplc accessories | mobile phase<br />

6337<br />

Cup-Style Inlet Filters<br />

Description Porosity Qty. Part No.<br />

Stainless Steel Cup Filter 2µm 1 28981<br />

Stainless Steel Cup Filter 10µm 1 28982<br />

Replacement Cup Filter 2µm 1 28983<br />

Replacement Cup Filter 10µm 1 28984<br />

Economy Inlet Filters<br />

Description Porosity Qty. Part No.<br />

Stainless Steel Filter 2µm 1 79964<br />

Stainless Steel Filter 10µm 1 79966<br />

Hastelloy ® C Inlet Filter<br />

• Ideal for use with halogenated solvents<br />

• More inert than other types of<br />

stainless steel<br />

CPI Stainless Steel Inlet Filter<br />

• Unique knurled fitting connects securely to<br />

1/8" o.d. tubing<br />

• Comes with replaceable Tefzel ® ferrule<br />

5216<br />

6297<br />

Hastelloy ® C Inlet Filter Specifications<br />

Material:<br />

Hastelloy ® C<br />

Porosity: 2µm<br />

Max. Temperature: 500°C<br />

Plumbing:<br />

Slip Fit to 1.5 or 3.0mm i.d. Tubing<br />

Hastelloy ® C Inlet Filters<br />

Description Porosity Qty. Part No.<br />

For 0.062" (1.5mm) i.d. 2µm ea 9400<br />

For 0.125" (3.0mm) i.d. 2µm ea 9402<br />

CPI Stainless Steel Inlet Filter Specifications<br />

Material: 316 Stainless Steel, Tefzel ®<br />

Porosity: 10µm<br />

Max. Temperature: 100°C<br />

Plumbing:<br />

CPI Port for 1/8" o.d. Tubing<br />

CPI Stainless Steel Inlet Filters<br />

Description Porosity Qty. Part No.<br />

Stainless Steel Filter 10µm ea 250145<br />

Replacement Filter 10µm 2 250147<br />

Replacement Tefzel ® Ferrules — 5 210144<br />

www.discoverysciences.com<br />

123


analytical hplc<br />

Mobile Phase Inlet Filters<br />

Metal-Free Inlet Filter<br />

• Ideal for IC or biochromatography applications<br />

• Replaceable polyethylene filter elements<br />

• Threaded body allows easy connection to 1/4-28 fittings<br />

Stainless Steel Slip-On Inlet Filter<br />

• Economical mobile phase inlet filtration<br />

• 316 stainless steel filters<br />

best<br />

seller<br />

hplc accessories | mobile phase<br />

Metal-Free Inlet Filter Specifications<br />

Material:<br />

PEEK Body, Polyethylene Filter<br />

Porosity: 20µm<br />

Max. Temperature: 100°C<br />

Plumbing:<br />

1/4-28 Port for 1/16" or 1/8" o.d. Tubing<br />

Metal-Free Inlet Filters<br />

Description Porosity Qty. Part No.<br />

For 1/8" o.d. 20µm ea 32170<br />

For 1/16" o.d. 20µm ea 32171<br />

Replacement Filter Elements 20µm 5 32173<br />

5217 5564<br />

Stainless Steel Slip-On Inlet Filter Specifications<br />

Material:<br />

316 Stainless Steel<br />

Porosity: 2µm or 10µm<br />

Max. Temperature: 500°C<br />

Plumbing:<br />

Slip Fit to 1.5, 2.2, or 3.0mm i.d. Tubing<br />

Stainless Steel Slip-On Inlet Filters<br />

Description Porosity Qty. Part No.<br />

For 0.062" (1.5mm) i.d. 2µm 5 28861<br />

For 0.062" (1.5mm) i.d. 10µm 5 28863<br />

For 0.085" (2.2mm) i.d. 2µm 5 28865<br />

For 0.085" (2.2mm) i.d. 10µm 5 28867<br />

For 0.125" (3.0mm) i.d. 2µm 5 28869<br />

For 0.125" (3.0mm) i.d. 10µm 5 28871<br />

tech tip<br />

How do I choose a mobile phase inlet filter?<br />

Choose the filter material based on the analysis<br />

Stainless Steel: Suitable for most applications except very strong acid or halogenated<br />

solvents<br />

Hastelloy ® C: More inert grade of stainless steel, suitable for halogenated solvents<br />

where halide salts tend to corrode other types of stainless steel<br />

Polyethylene: Good general inertness. Ideal for any metal-free or IC application.<br />

Choose the filter porosity based on the HPLC flow rate<br />

Flow Rate (mL/min)<br />

Inlet Filter Porosity<br />

0.1–5 2µm<br />

1–10 10µm<br />

10–50 20µm<br />

related product<br />

Looking for low-pressure tubing?<br />

<strong>Grace</strong> carries a full line of low-pressure<br />

tubing. See page 387.<br />

related products<br />

Looking for mobile<br />

phase degassers?<br />

See pages 128 and 129.<br />

5531<br />

6508a<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

124 www.discoverysciences.com


analytical hplc<br />

Mobile Phase Delivery/Storage-Bottle Kits<br />

Kontes Three-Valve Bottle Kit<br />

These bottle kits have three color-coded,<br />

helium-tight valves to maintain a sealed<br />

environment between runs. Each kit comes<br />

complete with a three-valve cap, a safetycoated<br />

conical bottom Kontes Ultra-Ware ®<br />

reservoir, and the required 1/4-28 fittings<br />

and tubing.<br />

Kontes Three-Valve Bottle Kit<br />

Description Thread Size Part No.<br />

Three-Valve Bottle Kit<br />

1 Liter GL-45 31870<br />

2 Liter GL-45 31871<br />

5 Liter GL-45 31872<br />

THF-Resistant Three-Valve Bottle Kit<br />

1 Liter GL-45 31875<br />

2 Liter GL-45 31876<br />

5 Liter GL-45 31877<br />

Kontes Three-Hole Bottle Kit<br />

The standard Three-Hole bottle kit includes<br />

a safety-coated conical-bottom Kontes Ultra-<br />

Ware ® reservoir and a Three-Hole cap with<br />

1/4-28 threads on both the top and bottom<br />

portions of the cap to separate tubing lines<br />

inside and outside the reservoir.<br />

Kontes Three-Hole Bottle Kit<br />

Description Thread Size Part No.<br />

Three-Hole Bottle Kit<br />

1 Liter GL-45 31880<br />

2 Liter GL-45 31881<br />

5 Liter GL-45 31882<br />

Kontes Economy Three-Hole Bottle Kit<br />

The Economy Three-Hole Bottle Kit<br />

includes a safety-coated flat-bottom<br />

Kontes Ultra-Ware reservoir and an<br />

Economy Three-Hole cap with 1/4-28<br />

threads on the top portion of the cap<br />

(2 x 1/8" and 1 x 1/16" through hole).<br />

Pass a single length of tubing through<br />

the cap into the reservoir.<br />

best<br />

value<br />

1842<br />

2226<br />

Kontes Safety-Coated Glass Bottles<br />

• Plastic coating blocks UV light and retains glass<br />

fragments if breakage occurs<br />

• Safety pressure rating of 6psig<br />

• Conical bottom reservoir delivers all mobile phase<br />

Kontes Ultra-Ware ® reservoirs are made from the most<br />

chemically inert glass available to prevent leaching<br />

extractables into the mobile phase solvent. In case of an<br />

accident, the external safety coating retains glass fragments<br />

and serves as a UV blocking agent up to 385nm.<br />

Conical Bottom<br />

5574<br />

Flat Bottom<br />

Kontes Safety-Coated Bottles<br />

Description Thread Size Part No.<br />

Kontes Ultra-Ware ® Conical Bottom Reservoir<br />

1 Liter GL-45 10133<br />

2 Liter GL-45 10135<br />

5 Liter GL-45 10137<br />

Kontes Ultra-Ware ® Flat-Bottom Reservoir<br />

1 Liter GL-45 10967<br />

2 Liter GL-45 10968<br />

5 Liter GL-45 10969<br />

tech tip<br />

Tips for safe helium sparging<br />

As with any glass container, a nick or score caused by normal<br />

lab usage will lessen the integrity of the glass, so beware in any<br />

pressure or vacuum application. Ideally, use safety-coated glass<br />

bottles, and perform vacuum filtration and/or helium sparging<br />

under a protective hood.<br />

5577<br />

hplc accessories | mobile phase<br />

1841<br />

Kontes Economy Three-Hole Bottle Kit<br />

Description Thread Size Part No.<br />

Economy Three-Hole Bottle Kit<br />

1 Liter GL-45 95393012<br />

2 Liter GL-45 95393022<br />

5 Liter GL-45 95393052<br />

10 Liter GL-45 95393013<br />

20 Liter GL-45 95393023<br />

www.discoverysciences.com<br />

125


analytical hplc<br />

hplc accessories | mobile phase<br />

Mobile Phase Delivery/Storage Bottles<br />

Glass Mobile Phase Bottles<br />

• Economical<br />

• Graduated markings<br />

• Borosilicate glass<br />

Economical glass mobile phase<br />

bottles with un-lined storage caps<br />

are available in 500mL, 1000mL,<br />

and 2000mL sizes. These graduated<br />

borosilicate glass bottles can be<br />

ordered individually or by the case.<br />

Glass Mobile Phase Bottles<br />

Volume Thread Size Qty. Part No.<br />

500mL 33-430 1 2198191<br />

500mL 33-430 6 219816<br />

1000mL 38-430 1 2198201<br />

1000mL 38-430 6 219826<br />

1000mL GL-45 1 2199301<br />

1000mL GL-45 6 2193011<br />

2000mL GL-45 1 2199311<br />

2000mL GL-45 6 219311<br />

Kontes Mobile Phase Caps<br />

• Sparge and deliver solvent with one cap<br />

• Available with or without valves<br />

Kontes Three-Valve Cap has three 1/4-28 threaded ports<br />

and color-coded, helium-tight valves to maintain a sealed<br />

environment. The Standard Three-Hole Cap has 1/4-28<br />

threads on the top and bottom portions of the cap for separate<br />

tubing lines inside and outside the reservoir. The Economy<br />

Three-Hole Cap has 1/4-28 threads on the top portion of<br />

the cap (2 x 1/8" and 1 x 1/16" through holes). Pass a single<br />

length of tubing through the cap into the reservoir.<br />

Three-Hole Cap<br />

best<br />

value<br />

5588 5573<br />

Three-Valve Cap<br />

Kontes Mobile Phase Caps<br />

Description Thread Size Part No.<br />

Three Valve Cap GL-45 10140<br />

Standard Three-Hole Cap GL-45 10974<br />

Economy Three-Hole Cap GL-45 10973<br />

TFE-Storage Cap, No Holes GL-45 10153<br />

5595<br />

Alltech ® Economy Mobile Phase Caps<br />

• Most economical way to helium sparge<br />

and deliver HPLC mobile phases<br />

• Three-hole cap with or without threaded ports<br />

The MP1-Cap has a PTFE insert and a polypropylene screw<br />

collar. The insert contains three 1/4-28 threaded ports with<br />

through-holes* that allow the tubing to either be pushed<br />

through or connected with flanged fittings. The MP2-Cap<br />

is made from Tefzel ® and polypropylene and has three<br />

unthreaded holes* for tubing insertion. Just push the tubing<br />

through! Alltech also offers PTFE lined screw caps with<br />

one or two pre-drilled holes (not shown).<br />

*(2x1/8" and 1x1/16")<br />

MP1-Cap<br />

6338 6339<br />

Alltech ® Economy Mobile Phase Caps*<br />

Description Qty. Thread Size Part No.<br />

MP1-Cap ea GL-45 955664<br />

MP2-Cap ea GL-45 955665<br />

1-Hole Screw Cap 4/pk 38-430 9547<br />

2-Hole Screw Cap 4/pk 38-430 9541<br />

*Not intended for build-up of helium environment.<br />

Omnifit ® Mobile Phase Caps<br />

• Anti-twist design prevents<br />

tubing from getting tangled<br />

• Highly inert PTFE wetted<br />

surface<br />

• Stainless steel inserts prevent<br />

cross-threading<br />

MP2-Cap<br />

best<br />

value<br />

Omnifit ® bottle caps are made<br />

6334<br />

from a single PTFE block built into<br />

a Polypropylene threaded cap. The anti-twist design enables<br />

the central block to turn independently when the cap is being<br />

connected onto the bottle. This prevents tubing from being<br />

twisted. The 1/4-28 ports have reinforced non-wetted stainless<br />

steel threaded inserts. Optional Kel-F ® turn-key valves provide<br />

a completely closed system.<br />

Omnifit ® Mobile Phase Caps<br />

Description Thread Size Part No.<br />

Two-Hole Cap GL-45 53280<br />

Three-Hole Cap GL-45 53281<br />

Two-Hole Cap with Valve GL-45 53282<br />

Three-Hole Cap with Valve GL-45 53283<br />

126 www.discoverysciences.com


analytical hplc<br />

Kontes Ultra-Ware ® Filtration<br />

Cap System<br />

Alltech ® Solvent Filtration<br />

Apparatus<br />

Now you can filter, degas, and<br />

deliver mobile phase from the same<br />

reservoir with this modular system. The<br />

Filtration/Degassing Cap uses a 47mm<br />

diameter membrane to filter directly<br />

into the reservoir. Vacuum degassing<br />

is accomplished by closing the Hi-Vac<br />

valve on the Solvent Pickup Adapter.<br />

This system comes complete with the<br />

Filtration/Degassing Cap, a standard<br />

Solvent Pickup Adapter, a Conical<br />

Bottom Kontes Ultra-Ware ® Reservoir,<br />

and the required fittings and tubing.<br />

Conical Bottom<br />

Reservoir<br />

A<br />

Solvent Pick-Up<br />

Adapter<br />

0860 2765<br />

0861<br />

B<br />

Filtration/<br />

Degassing Cap<br />

C<br />

5575<br />

The Alltech ® Solvent Filtration Apparatus<br />

rapidly filters and degasses HPLC<br />

and IC mobile phases. Depending on<br />

your analytical requirements, several<br />

interchangeable funnel and flask options<br />

are available. You can easily replace<br />

the funnel with the solvent pickup<br />

adapter. The Solvent Pickup Adapter<br />

draws solvent directly from a reagent<br />

bottle through a 47mm filter and into the<br />

collecting flask.<br />

Glass Funnel<br />

Clamp<br />

Filter of Choice<br />

Solvent<br />

Pickup<br />

Adapter<br />

6266<br />

hplc accessories | mobile phase<br />

CTFE Adapter<br />

Vacuum Adapter<br />

Support Frit<br />

Fritted Glass<br />

Support Base<br />

Solvent<br />

Bottle<br />

D<br />

0866 0867<br />

2770<br />

E<br />

F<br />

125mL/1L<br />

2L<br />

2771<br />

Kontes Ultra-Ware ® Filtration Systems<br />

Graphic Description Part No.<br />

Filtration Cap System<br />

— With 1 Liter Reservoir 31860<br />

— With 2 Liter Reservoir 31861<br />

— With 5 Liter Reservoir 31862<br />

Replacement Parts and Accessories<br />

A 1 Liter Reservoir* 10133<br />

A 2 Liter Reservoir* 10135<br />

A 5 Liter Reservoir* 10137<br />

B Solvent Pickup Adapter (THF Resistant) 31869<br />

C Filtration/Degassing Cap 10141<br />

D CTFE, 1/4-28 to 1/8" Barb Adapter 10128<br />

D CTFE, 1/4-28 to 5/32" Barb Adapter 10139<br />

E Vacuum Adapter 1/4-28 to 1/4" i.d. Tubing 10127<br />

F Replacement Support Frit 31801<br />

*Bottles have GL-45 threads.<br />

Alltech ® Solvent Filtration Apparatus<br />

Description<br />

Part No.<br />

Solvent Filtration Apparatus<br />

125mL Flask, 15mL Funnel, 25mm Filter Support,<br />

2331<br />

25mm Clamp, 0.2µm Nylon Filters 100/pk<br />

1L Flask, 300mL Funnel, 47mm Filter Support,<br />

2001<br />

47mm Clamp, 0.2µm Nylon Filters 100/pk<br />

2L Flask, 500mL Funnel, 47mm Filter Support,<br />

2003<br />

47mm Clamp, 0.2µm Nylon Filters 100/pk<br />

Replacement Parts and Accessories<br />

125mL Flask (For 2331) 2337<br />

1L Flask (For 2001) 350062<br />

2L Flask (For 2003) 350066<br />

15mL Glass Funnel (For 2331) 2333<br />

300mL Glass Funnel (For 2001) 350064<br />

500mL Glass Funnel (For 2003) 350067<br />

1L Glass Funnel (for 2003) 350070<br />

25mm Fritted Base Support (For 2331) 2335<br />

47mm Fritted Base Support (For 2001) 350065<br />

47mm Fritted Base Support (For 2003) 350068<br />

25mm Aluminum Clamp (For 2331) 2339<br />

47mm Aluminum Clamp (For 2001, 2003) 350061<br />

47mm Solvent Pick Up Adapter 2343<br />

47mm Nylon Filter Membranes, 0.2µm, 100/pk 2034<br />

25mm Nylon Filter Membranes, 0.2µm, 100/pk 2050<br />

www.discoverysciences.com<br />

127


analytical hplc<br />

hplc accessories | mobile phase<br />

Alltech ® On-Line Degassing Systems<br />

• Most advanced degassing technology<br />

• Product range meets every need and budget<br />

• Upgrade capabilities available<br />

Flow rate instability and baseline noise are the likely result<br />

of dissolved air in the mobile phase. Eliminate these problems<br />

with the Alltech ® On-line Degassing System. Unlike helium<br />

sparging, degassing online does not require extra mobile<br />

phase preparation steps. Save time and avoid the expense,<br />

inconvenience, and hazards associated with helium tanks.<br />

Every Alltech ® On-Line Degassing System is equipped with our best degassing technology, and is available in two families,<br />

three flow ranges, and four channels to meet every need and budget. First decide which family features meet your need, then<br />

choose the degassing system with the flow range and number of channels you need today. If your needs change in the future<br />

you can upgrade at any time by either replacing or adding up to four degassing channels per unit.<br />

Advanced Degassing Technology from Three Key Components<br />

Teflon ® AF Degassing Membrane<br />

50x more efficient than competitive PTFE membranes.<br />

This means channel volumes are 10x smaller and<br />

equilibration is 4x faster.<br />

UV Absorbance @ 215nm<br />

0.300<br />

0.250<br />

0.200<br />

0.150<br />

0.100<br />

0.050<br />

Teflon ® AF Degassing Membrane<br />

PTFE Membrane<br />

Air saturated Methanol @ 1.0mL/min<br />

0.000<br />

0 200 400 600 800 1000 1200 1400 s<br />

Time Required to Reach Optimum Degassing Level<br />

Continuous-Run Vacuum Pump<br />

Delivers a steady baseline. Competitive degassers<br />

have fluctuating baselines due to the on/off cycle of the<br />

vacuum pump.<br />

UV Absorbance @ 215nm<br />

0.100<br />

0.090<br />

0.080<br />

0.070<br />

0.060<br />

0<br />

Baseline Using Alltech ® Degassing System<br />

Baseline Using Competitor’s Degassing System<br />

Air saturated Methanol @ 1.0mL/min<br />

200 400 600<br />

800 1000 1200 1400 s<br />

5768 5769<br />

6508a<br />

Low-permeation Tubing<br />

Double-layered with an inert PTFE inner layer and a gas<br />

impermeable outer layer so solvent remains degassed as<br />

it travels to the pump.<br />

Oxygen (ppm) / Meter of Tubing<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

PTFE Tubing<br />

1/8" OD x 1/16" ID<br />

Regassing Rate<br />

@ 1mL/min.<br />

Low-permeation Tubing<br />

Standard PTFE Tubing<br />

Low-permeation Tubing<br />

1/8" OD x 1/16" ID<br />

1911B<br />

128 www.discoverysciences.com


analytical hplc<br />

Alltech ® Online Degassing Systems<br />

Degassing System<br />

HPLC Pump<br />

Detector<br />

Low-permeation Tubing<br />

Injector<br />

HPLC Column<br />

Mobile Phase<br />

Eliminate extra mobile phase preparation steps by degassing online.<br />

6524<br />

Choice of Two Degasser Families:<br />

Elite Degasser Family<br />

In addition to the key degassing components, the Elite<br />

family incorporates a vacuum sensor, validation output and<br />

a four-year warranty. The sensor not only detects and alerts<br />

you to leaks, it also communicates with the vacuum pump. If<br />

a change in vacuum is detected due to mobile phase flow rate<br />

changes, the pump can compensate by changing its speed.<br />

The validation output records vacuum level to satisfy ISO and<br />

system validation requirements.<br />

Specification Elite Degasser Family Select Degasser Family<br />

Membrane Type: Teflon ® AF Teflon ® AF<br />

Vacuum Pump Type: Continuous-run, self-adjusting speed Continuous-run, one-speed<br />

Low-permeation Fittings and Tubing: Yes Yes<br />

Vacuum Sensor: Yes No<br />

Validation Output: Yes (5mVDC/1mm Hg) No<br />

Warranty: 4-year 1-year<br />

Flow Range Choices:<br />

Micro:<br />

Analytical:<br />

Semi-prep:<br />

0–1mL/min, 195µL internal volume<br />

0–5mL/min, 480µL internal volume<br />

0–10mL/min, 925µL internal volume<br />

Select Degasser Family<br />

The Select family has identical degassing efficiency to<br />

the Elite line since it contains the same key components.<br />

However, by omitting the vacuum sensor and validation<br />

output, and applying the industry standard one-year warranty,<br />

the Select family is available at an economical price.<br />

0–1mL/min, 195µL internal volume<br />

0–5mL/min, 480µL internal volume<br />

0–10mL/min, 925µL internal volume<br />

Universal Power Supply: Yes Yes<br />

Dimensions: 5" H x 3" W x 10" D (13cm H x 8cm W x 25cm D) 5" H x 3" W x 10" D (13cm H x 8cm W x 25cm D)<br />

hplc accessories | mobile phase<br />

On-Line Degassing Systems<br />

Description<br />

Elite Family<br />

Part No.<br />

Select Family<br />

Part No.<br />

Micro, 0–1mL/min, 195µL Internal Volume<br />

2 Channel 590507 590500<br />

4 Channel 590508 590501<br />

Analytical, 0–5mL/min, 480µL Internal Volume<br />

1 Channel 590509 590502<br />

2 Channel 590510 590503<br />

3 Channel 590511 590504<br />

4 Channel 590512 590505<br />

Semi-prep, 0–10mL/min, 925µL Internal Volume<br />

1 Channel 590517 590514<br />

2 Channel 590513 590506<br />

3 Channel 590518 590515<br />

4 Channel 590519 590516<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

Channel Upgrade Kits*<br />

Description<br />

Part No.<br />

Micro, 0–1mL 590520<br />

Analytical, 0–5mL 590521<br />

Semi-prep, 0–10mL 590522<br />

*Includes degassing channel, vacuum tubing, mounting screw, identification sticker,<br />

and instructions.<br />

Face Plates*<br />

Description<br />

Part No.<br />

For 1 Channel<br />

590506A<br />

For 2 Channel<br />

590506B<br />

For 3 Channel<br />

590506C<br />

For 4 Channel<br />

590506D<br />

*To replace an existing degassing channel, only a channel upgrade kit is necessary.<br />

To add more channels, a new face plate is also required.<br />

Upgrade Labor Charge*<br />

Description<br />

Part No.<br />

Labor 590525<br />

*Channel upgrade kit and face plate must be ordered separately.<br />

www.discoverysciences.com<br />

129


analytical hplc<br />

hplc accessories | mobile phase<br />

Helium Sparger Kit<br />

• 38-430 threaded cap<br />

• Available in single, binary, or<br />

ternary versions<br />

The Alltech ® Helium Sparger<br />

kit has a 316 stainless steel<br />

sparging element which may be<br />

immersed in the mobile phase<br />

reservoir. A length of 1/8" PTFE<br />

tubing connects the sparger to<br />

a flow-control valve (optional)<br />

which connects to a source of<br />

helium, and allows the bubble<br />

rate to be adjusted. A 38mm,<br />

two-hole cap attaches to the<br />

top of standard 1-liter mobile<br />

phase reservoirs or to any 4-liter<br />

solvent bottle. All kits include<br />

tubing, reservoir cap(s), and sparging element(s). For kits with<br />

a flow control valve, one valve controls the bubble rate on all<br />

sparging outlets.<br />

Ultrasonic Bath<br />

• For laboratory cleaning,<br />

solvent degassing, and<br />

dispersing slurries<br />

• 2.8-liter tank<br />

• Mechanical timer<br />

• Overall size:<br />

12" H x 13.3" W x 11.6" L<br />

• Tank Size:<br />

4.0" H x 5.5" W x 9.5" L<br />

Flow Control Valve<br />

38mm<br />

Cap<br />

PTFE Tubing<br />

Sparging<br />

Element<br />

Helium Sparger Kits<br />

Description<br />

Part No.<br />

Single Sparger Kit with Flow Control Valve 28915<br />

Binary Sparger Kit with Flow Control Valve 28919<br />

Ternary Sparger Kit with Flow Control Valve 28923<br />

Replacement Sparging Element 28862<br />

Ultrasonic Bath<br />

Description<br />

Part No.<br />

120V 9490<br />

220V 9490-220V<br />

tech tip<br />

Use caution when filtering<br />

As with any vacuum or pressure application, glassware cannot<br />

be guaranteed against breakage due to varying conditions of<br />

field usage. Be sure to filter in a glass hood. Safety-coated glass<br />

bottles are always recommeneded.<br />

0881<br />

5602<br />

Vacuum Filtration<br />

System<br />

47mm<br />

Filter<br />

Membrane<br />

GL-45<br />

Threads<br />

Filter Funnel System<br />

Interchange Filter and<br />

In-Line Cap<br />

Base<br />

4391<br />

47mm<br />

Filter<br />

Membrane<br />

GL-45<br />

Threads<br />

best<br />

seller<br />

In-Line Filtration System<br />

new<br />

• Eliminate solvent transfer steps with direct filtration into<br />

any GL-45 reservoir<br />

• Interchange funnels and in-line filter cap handle any<br />

filtration volume<br />

• Durable polypropylene<br />

construction<br />

New Features:<br />

• Stainless steel<br />

connection at vacuum<br />

source<br />

• Retainer ring prevents<br />

filter from twisting during<br />

assembly<br />

• A sealing o-ring in the<br />

neck of the GL-45 for a tighter seal<br />

Stainless<br />

Steel<br />

Connect<br />

Vacuum<br />

Source<br />

Stainless<br />

Steel<br />

Connect<br />

Vacuum<br />

Source<br />

Base<br />

Alltech ® Vacuum Filtration Systems<br />

Description Qty. Part No.<br />

1L Filter Funnel System<br />

1 6409<br />

Includes: Base, Adapter Kit, Mesh Filter Support,<br />

1L Funnel<br />

2L Filter Funnel System<br />

1 6429<br />

Includes: Base, Adapter Kit, Mesh Filter Support,<br />

2L Funnel<br />

In-Line Filtration System<br />

1 6407<br />

Includes: Base, Adapter Kit, Mesh Filter Support,<br />

In-Line Filter Cap<br />

Replacement Parts and Accessories<br />

1L Funnel 1 6473<br />

In-Line Filter Cap 1 6463<br />

Hose Barb Adapter Kit (includes eight adapters) 1 6438<br />

Stainless Steel Mesh Filter Support Ring 1 6421<br />

Silicone Rubber O-Ring 1 8619230<br />

Retainer Ring 1 8619231<br />

4385<br />

130 www.discoverysciences.com


analytical hplc<br />

Alltech ® Adjustable<br />

Backpressure Regulators<br />

• Constant backpressure, even with changing flow<br />

• Ultra-low dead volume—under 0.6µL<br />

• Easily adjusts by hand—no cartridges<br />

best<br />

seller<br />

Optimize Fixed Backpressure<br />

Regulators<br />

• Flow-through design—use in-line or as a terminator<br />

• May be immersed in the waste solvent bottle<br />

• 1/4-28 ports for tubing connections<br />

The Alltech ® Backpressure Regulator prevents bubbles from<br />

forming in detector flow cells by exerting a constant pressure.<br />

The pressure will not vary with mobile phase composition or<br />

flow rate. Optimized port configuration delivers an internal<br />

volume of less than 0.6µL. A convenient, knurled knob adjusts<br />

the pressure, and eliminates cartridge changes. It also allows<br />

adjustments to be made without interrupting flow.<br />

Alltech ® Adjustable Backpressure Regulators<br />

Description<br />

Part No.<br />

0–100psig 39021<br />

0–300psig 39022<br />

100–600psig 39023<br />

100–1500psig 39024<br />

4704<br />

These flow-through, backpressure regulators prevent solvent<br />

outgassing in your LC detector. More than a flow restrictor,<br />

Optimize fixed regulators maintain a consistent backpressure,<br />

regardless of viscosity or flow rate. Pressure ratings are<br />

preset to their listed value. Internal volume is 100 microliters.<br />

They are supplied with fittings, and complete instructions.<br />

Optimize Fixed Backpressure Regulators<br />

Description<br />

Part No.<br />

10psig 29059<br />

30psig 29060<br />

60psig 29062<br />

100psig 29064<br />

150psig 29069<br />

5625<br />

hplc accessories | mobile phase<br />

Alltech ® Liquid Pressure Gauges<br />

• Inert 316 stainless steel<br />

construction<br />

• Built-in 1/16" connecting tee<br />

for in-line use<br />

• Non-wetted glycerine-filled<br />

face plate<br />

These liquid gauges come<br />

equipped with a 10-32 threaded,<br />

1/16" connecting tee for attaching it in-line to the<br />

solvent stream. Each gauge is constructed of 316 stainless<br />

steel and features an easy-to-read 2-1/2" face plate.<br />

2349<br />

related products<br />

For high-pressure fittings,<br />

see pages 112–118.<br />

6280<br />

Alltech ® Pressure Gauges<br />

Description<br />

Part No.<br />

0–100psig 19255<br />

0–300psig 19256<br />

0–1000psig 19257<br />

0–3000psig 19258<br />

0–5000psig 19259<br />

related products<br />

For PEEK tubing, see<br />

pages 384–385.<br />

5535<br />

www.discoverysciences.com<br />

131


analytical hplc<br />

hplc accessories | pump<br />

Optimize Pump Replacement Parts<br />

OPTI-MAX ® Cartridge Check Valves<br />

• Economical, disposable cartridge with reusable holder<br />

• Available with PEEK or stainless steel cartridges<br />

• Same cartridge fits inlet<br />

and outlet housings<br />

• Cartridge fits multiple<br />

housing brands for<br />

reduced inventory<br />

OPTI-MAX ® Check Valve Assembly (Holder and Cartridge)<br />

Description<br />

Inlet<br />

Part No.<br />

Outlet<br />

Part No.<br />

Standard Assembly (1/8" Ball) For:<br />

Agilent/HP 1050, 1100 155231* 155232<br />

Bio-Rad ® 1330 32350 32351<br />

Dionex ® GPM-2,DXP, AGP Analytical, 32354 32356<br />

2000, 4000<br />

Gilson ® /Rainin ® 5, 10, 25mL S, SC Heads 155511 155521<br />

PerkinElmer ® Inlet Model 250, Series 4, 32358 32359<br />

200, 400, 410, 620, Integral 4000<br />

Spectra-Physics ® 8100, 8700, 8800 155441 155452<br />

Series, P-Series<br />

Waters ® M45, M45G, M501, 6K, 6KA, 155001 155111<br />

510, 590, 600E, 610<br />

Low Flow Rate Assembly (1/16" Ball) For:<br />

Hitachi ® 655, L6000, L6200, L6200A 155341 155352<br />

Hitachi ® L-7100 (LaChrom) 155233 155234<br />

Shimadzu ® LC-10 AT, LC-10ATVP 155235 155236<br />

Shimadzu ® LC-10AD, LC-600, LC-9A 155237 152238<br />

Waters ® 2690 Alliance, 616 155250 155251<br />

Waters ® 625, 626 155252 155253<br />

*Replace cartridge for active inlet valve.<br />

2376<br />

OPTI-MAX ® Replacement Cartridges<br />

Description Qty. Part No.<br />

Standard Series (1/8" Ball)<br />

PEEK 2 151002<br />

316 Stainless Steel 2 10481<br />

Low Flow Rate Series (1/16" Ball)<br />

PEEK 2 10482<br />

316 Stainless Steel 2 10483<br />

Optimize Pump Pistons<br />

• Pump pistons meet or exceed manufacturer’s standards.<br />

Optimize Pistons<br />

Manufacturer<br />

Part No.<br />

<strong>Grace</strong><br />

Part No.<br />

Description<br />

Pump Pistons For:<br />

Agilent/HP 1050, 1100 5062-2441 11907<br />

Agilent/HP 1090 3980-0672 11908<br />

Beckman ® 110A, 110B, 112, 112M 243053 11901<br />

Dionex ® Analytical 36904 11904<br />

Hitachi ® 655, L6000, L6200/A, 7100 635-1021 11909<br />

(LaChrom)<br />

LDC, Milton Roy ® 801306 980014<br />

Shimadzu ® LC-6A LC-1A, LC-10AS, 228-12904-93 11912<br />

LC-10AT, LC-10ATVP<br />

Shimadzu ® LC-600/LC-9A, LC-10AD 228-18523-91 11913<br />

Spectra-Physics ® 8800, 8810, P-1000, A3102-010 11914<br />

P-2000, P-4000<br />

Waters ® M510, M590, M600E, M610, 25656 11915<br />

M6000, M6000A<br />

Waters ® 2690 Alliance 270959 119165<br />

OPTI-SEAL ® Pump Seals<br />

• Ideal for aqueous solutions<br />

• Proprietary UHMW-PE blend, OS-10.1<br />

ITB Improved PTFE-Blend Seals<br />

• Ideal for high organic solutions<br />

or when broad solvent<br />

compatibility is required<br />

• Proprietary PTFE blend<br />

2379<br />

OPTI-SEAL ® Pump Seals<br />

2378<br />

Manufacturer<br />

Part No.<br />

OPTI-SEAL ®<br />

Part No.<br />

ITB Seal<br />

Part No.<br />

Manufacturer<br />

Description<br />

Qty.<br />

Agilent/HP 1050, 1100 5062-8516 ea 32056 11883<br />

Bio-Rad 1350, 2700 1250302 ea 32050 11875<br />

Hitachi 655, L6000, L6200, L6200A, L-7100, LaChrom ® 655-1080 10 25649 11886<br />

ea 25648 11887<br />

LDC Milton Roy 206129001 10 25643 11889<br />

Shimadzu LC-6A, LC-7A, LC-10AS, LC-10AT, LC-10ATVP 228-11999-00 10 25645 11893<br />

ea 25644 11894<br />

LC-600/LC-9A, LC-10AD 228-18745-00 10 32063 —<br />

ea 32062 11896<br />

Spectra-Physics 8800, 8810, P-1000, P-2000, P-4000 A2963-010 10 11864 —<br />

ea 11865 11898<br />

Waters M45, M45G, M501, M510, M590, M600E, 22934 10 25639 11899<br />

M610, M6000, M6000A ea 25638 11866<br />

Waters 2690 Alliance ® 26938 10 119166 —<br />

ea 119167 —<br />

132 www.discoverysciences.com


analytical hplc<br />

ASI Pump Replacement Parts<br />

ASI Cartridge Check Valves<br />

• Self-priming<br />

• Rugged construction<br />

• Convenient and<br />

economical<br />

• Superior flow stability<br />

The ASI cartridge has a<br />

15,000psig pressure limit.<br />

During routine maintenance, replace only the cartridge,<br />

not the entire assembly. Cartridges cost less than most<br />

conventional valve rebuild kits.<br />

Every valve is tested prior to shipping to ensure it passes<br />

a stringent set of performance specifications. A replaceable<br />

2µm outlet filter insures clog-free operation and protects the<br />

column from pump wear particles.<br />

ASI Check Valve Assembly (Holder and Cartridge)<br />

Pump Model<br />

Inlet<br />

Part No.<br />

Outlet<br />

Part No.<br />

Assembly For:<br />

Beckman ® 110, 112, 114, 116, 118, 125, 15811 15831<br />

126, 127, 128<br />

Gilson ® 5 and 10s, SC 15815 15835<br />

Hitachi ® 655, L6000, L6200, L6200A 15817 15837<br />

LKB 2150 15820 —<br />

Shimadzu ® LC600, LC6A, LC7A, LC9A, 15823 15843<br />

LC10A, LC10AS, LC10AT<br />

Spectra-Physics ® 8100, 8700, 8700, 8800, 15824 15844<br />

8810<br />

Waters ® M45, 510, 590, 6000 15828 15848<br />

Waters ® M501 and 600E 15828 15850<br />

Waters ® 6KEF, 6KAEF, 510EF, 600EF 15829 15849<br />

ASI Replacement Cartridges<br />

Inlet<br />

Part No.<br />

Outlet<br />

Part No.<br />

Pump Model<br />

ASI Replacement Cartridges For:<br />

Beckman ® 110, 112, 114, 116, 118 125, 126, 15854 16123<br />

127, 128<br />

Bio Rad ® 1330 and 1350 — 16124<br />

Gilson ® 5 and 10s, SC 15858 16127<br />

Hewlett-Packard ® 1090 15859 16128<br />

PerkinElmer ® Series 4, 200, 400, 410, 620, 15864 16133<br />

4000<br />

Shimadzu ® LC600, LC6A, LC7A, LC9A, 15866 16135<br />

LC10A, LC10AS, LC10AT<br />

Spectra-Physics ® 8100, 8700, 8800, 8810 15867 16136<br />

Waters ® M45, 501, 510, 590, 600E, 6000 16120 16139<br />

2240<br />

ASI Pump Pistons<br />

ASI offers precisionmanufactured<br />

replacement<br />

pump pistons. Superior<br />

surface finish of the piston<br />

rods improves piston seal<br />

lifetime.<br />

ASI Pistons<br />

ASI Pump Seals<br />

• Replacement seals for<br />

a variety of pumps<br />

• All seals below are<br />

UHMW-PE, unless<br />

otherwise specified<br />

Manufacturer<br />

Part No.<br />

<strong>Grace</strong><br />

Part No.<br />

Description<br />

Pump Pistons For:<br />

Gilson ® 10, SC 3650009 11746<br />

Gilson ® 5SC 3650008 11747<br />

Hitachi ® 655, L6000, L6200, L6200A, 810-1033 11760<br />

L7100<br />

Shimadzu ® LC-600, LC-9A, LC-10AD 228-18523-91 11766<br />

Spectra-Physics ® 8800, 8100 A3102-010 11767<br />

Waters ® M-45, 501 26524 11364<br />

Waters ® M-510, 590, 600, 6000 25656 11365<br />

Waters ® Ext. Flow 510EF, 590EF, 600EF,<br />

610EF, 650EF, 6000EF, 6000AEF<br />

60304 11366<br />

ASI Pump Seals<br />

Manufacturer<br />

Part No.<br />

<strong>Grace</strong><br />

Part No.<br />

Description<br />

Qty.<br />

Pump Seals For:<br />

Agilent 1090—PTFE ea 5062-2494 11679<br />

Agilent 1090—PTFE 10 11680<br />

Gilson ® /Rainin ® 5SC ea 5463088863 11675<br />

Gilson ® /Rainin ® 5SC 10 11676<br />

Hitachi ® 655, L6000, L6200, ea 655-1080 11681<br />

L6200A, L7100<br />

Hitachi ® 655, L6000, L6200, 10 11682<br />

L6200A, L7100<br />

Spectra-Physics ® 8800, 8100 ea A2962-010 11687<br />

Spectra-Physics ® 8800, 8100 10 11688<br />

Waters ® M45, 501, 510, 590, ea 22934 11695<br />

600, 6000<br />

Waters ® M45, 501, 510, 590, 10 11696<br />

600, 6000<br />

Waters ® M45, 501, 510, 590, ea 26613 11697<br />

600, 6000—PTFE<br />

Waters ® Ext. Flow UHMW ea 26644 11699<br />

2334<br />

2334<br />

hplc accessories | pump<br />

related products<br />

Accessories for your system. <strong>Grace</strong><br />

has an assortment of Accessories<br />

Quick Reference guides available for<br />

many popular instruments.<br />

• Waters ® Alliance ®<br />

System Accessories<br />

– Request M202<br />

• Agilent 1100 and 1200<br />

System Accessories<br />

– Request M203<br />

• Waters ® Acquity ®<br />

System Accessories<br />

– Request M204<br />

www.discoverysciences.com<br />

133


analytical hplc<br />

hplc accessories | pump<br />

PEEK Mixing Tee<br />

• Better mixing than a<br />

conventional tee<br />

• Inert, metal-free construction<br />

• Ideal for high-pressure gradient<br />

mixing<br />

Better mixing is the result of the<br />

5616<br />

turbulence generated by the angled ports and the flow<br />

through a PAT (PEEK alloyed with TFE) filter element. Solvent<br />

streams mix more thoroughly than with a conventional tee.<br />

This reduces baseline noise and improves high pressure<br />

gradient mixing or post-column reactions. Solvents contact<br />

PEEK and the PAT filter, providing a biocompatible, inert, and<br />

metal-free flow path. This tee has a 2.5µL internal volume,<br />

a pressure limit of 6000psig, and comes with fittings and<br />

ferrules.<br />

Fitting<br />

Double-Sided<br />

Ferrule<br />

Toroid Mixer<br />

PAT Filter<br />

PEEK Housing<br />

• High efficiency mixer for preparative<br />

chromatography<br />

• Precise and reliable<br />

Turbulence at<br />

Vertex Mixes<br />

Two Solvent<br />

Streams<br />

Peek Mixing Tee<br />

Description Qty. Part No.<br />

Mixing Tee with Fittings ea 32157<br />

Replacement PEEK Fittings 5 35752<br />

Replacement PEEK Ferrules 5 35730<br />

The unique design of the Toroid Mixer<br />

extends the mixing characteristics of<br />

a pulse dampener in higher flow rate<br />

applications. High efficiency mixing yields reproducible<br />

quantitation, better reproducibility of retention times, and<br />

reduced baseline noise due to uniform solvent composition.<br />

Featuring a clean-swept mixing chamber, the Toroid Mixer<br />

has no motors or moving parts.<br />

Toroid Mixer Specifications<br />

Internal Volume: 5mL<br />

Flow Range:<br />

10 to 200mL/min<br />

Maximum Pressure: 6000psig<br />

Flow Path:<br />

PEEK<br />

1024<br />

4708<br />

ASI Static Mixer<br />

• Interchangeable mixer cartridges<br />

• Selectable volume*<br />

• Suitable for analytical and micro<br />

LC flow rates<br />

ASI HyperShear Static Mixers use a<br />

highly efficient liquid-liquid shearing<br />

interface which induces vortex mixing<br />

over a wide flow rate range. The<br />

versatile cartridge design is available as an in-line, binary,<br />

or ternary inlet housing. Analytical volume housings accept<br />

350 or 500µL mixer cartridges. Low volume housings accept<br />

50, 150, or 250µL mixer cartridges. And Micro volume<br />

housings accept 2, 5, 10, or 25µL mixer cartridges. All are<br />

rated to 5000psig.<br />

ASI HyperShear Static Mixers<br />

SS<br />

Part No.<br />

PEEK<br />

Part No.<br />

Description<br />

Analytical Volume Housing<br />

In-Line 40167 —<br />

Binary Inlet 40168 —<br />

Ternary Inlet 40169 —<br />

Analytical Volume Mixer Cartridges<br />

350µL 40146 —<br />

500µL 40147 —<br />

Low Volume Housings<br />

In-line 20141 201411<br />

Binary Inlet 20143 201431<br />

Ternary Inlet 20145 201451<br />

Low Volume Mixer Cartridges<br />

50µL 20147 201471<br />

150µL 20148 201481<br />

250µL 20149 201491<br />

Micro Volume Housing<br />

In-Line 30167 —<br />

Binary Inlet 30168 —<br />

Ternary Inlet 30169 —<br />

Micro Volume Mixer Cartridges<br />

2µL 30146 —<br />

5µL 30147 —<br />

10µL 30148 —<br />

25µL 30166 —<br />

*Other cartridge volumes available, call for assistance.<br />

tech tip<br />

What should I consider when choosing a mixer volume?<br />

• For any given flow rate, the more mixing volume, the better<br />

the mixing and lower the baseline noise.<br />

• The smaller the mixing volume, the better the definition and<br />

sharpness of step gradients.<br />

• High-pressure multi-pump gradient systems typically require<br />

far less mixing volume than low-pressure single-pump<br />

gradient systems.<br />

4707<br />

Toroid Mixer<br />

Description<br />

Part No.<br />

Toroid Mixer, Biocompatible 060143<br />

134 www.discoverysciences.com


analytical hplc<br />

Hamilton ® Priming Syringe<br />

• Ideal for use with Waters ® pumps<br />

Hamilton ® Priming Syringe<br />

Description<br />

Part No.<br />

10mL GasTight Priming Syringe 81662<br />

Draw Needles for Waters ® Pump 25559<br />

OPTI-PRIME Valve<br />

• Convenient—onehanded<br />

operation<br />

• Efficient—no need<br />

to remove syringe<br />

• Inert—PPS, TFE, and<br />

316SS wetted surfaces<br />

The syringe of the<br />

OPTI-PRIME serves<br />

as a handle to open the<br />

OPTI-PRIME valve,<br />

allowing one-handed operation. At a 45° angle, air bubbles<br />

rise to the top of the syringe, allowing purging and priming<br />

without removing the syringe.<br />

1896<br />

1898<br />

5506<br />

Valve open<br />

at 45º to<br />

prime pump<br />

Valve<br />

closed<br />

OPTI-PRIME Valve<br />

Description<br />

Part No.<br />

OPTI-PRIME Priming Valve 11647<br />

OPTI-PRIME Priming Valve w/Safety Syringe 11648<br />

Optimize Safety Syringe 11649<br />

Pump Inlet Kit<br />

Install the Pump Inlet Kit between<br />

the mobile phase reservoir<br />

and the pump to allow rapid<br />

priming and solvent changeover.<br />

A luer-lock adapter in the side<br />

port easily attaches to a priming<br />

syringe. Includes: one 3-way<br />

valve, one luer adapter, 2µm inlet<br />

filter, 100cm x 1/8" o.d. x 1/16"<br />

TFE tubing, two 1/8" flange-free<br />

fittings and ferrules.<br />

Pump Inlet Kit<br />

Description<br />

Part No.<br />

Pump Inlet Kit 39652<br />

Replacement Inlet Filter 9400<br />

LO-Pulse Dampener<br />

• 95% pulse reduction<br />

• Only 900µL internal<br />

volume<br />

As a pressure pulse enters<br />

the dampener, the flexible<br />

diaphragm transfers the<br />

pulse to the compressible<br />

fluid resulting in a 95+%<br />

reduction in pressure<br />

fluctuation. The low internalvolume<br />

(only 900µL at 6000psig) and flow-through design<br />

minimize gradient delays.<br />

LO-Pulse Dampener Specifications<br />

Flow Path Material:<br />

PEEK or 316 Stainless Steel<br />

Internal Volume:<br />

0.9mL<br />

Workable Pressure Range: 500–6000psig<br />

Maximum Temperature: 100°C<br />

Dampener Mechanism: Compressible Fluid<br />

5617<br />

2350<br />

hplc accessories | pump<br />

In-Line Bubble Trap<br />

This handy accessory<br />

installs on pump inlet lines<br />

by slip fitting onto the<br />

connecting tubing. Bubbles<br />

in the solvent line are<br />

trapped before reaching<br />

the pump. Includes<br />

mounting bracket.<br />

Slip fits to 3.0,<br />

2.2 or 1.5mm<br />

i.d. tubing<br />

LO-Pulse Dampener<br />

Description<br />

Part No.<br />

Stainless Steel 20-0218<br />

PEEK 120312<br />

Diaphragm Replacement Kit 120139<br />

related products<br />

Need a liquid pressure gauge?<br />

See page 131 for a complete selection.<br />

2349<br />

In-Line Bubble Trap<br />

Description<br />

Part No.<br />

In-Line Bubble Trap 01-0221<br />

4042<br />

www.discoverysciences.com<br />

135


analytical hplc<br />

hplc accessories | valves<br />

Rheodyne ® Model 7725 and 9725 Analytical Injectors<br />

• “Make-Before-Break” (MBB) switching for<br />

uninterrupted flow<br />

• Wider port angles provide improved fitting access<br />

• Position sensing switch option<br />

• Capable of injecting volumes from 1µL to 5mL with<br />

high precision<br />

• Suction Needle Adapter eliminates exposure of sample<br />

to metal of a syringe needle<br />

The 7725i features a built-in position-sensing switch, providing<br />

the chromatograph with a reproducible start signal. The 9725,<br />

9725i are biocompatible versions. Wetted materials are PEEK<br />

and Tefzel ® , making them ideal for applications requiring a<br />

metal-free flow path.<br />

Rheodyne ® Model 7125 Analytical Injectors<br />

• Versatile and reliable reputation<br />

• 5µL to 5mL sample loops available<br />

• Position-sensing switch option<br />

• The wetted materials are: Titanium, Tefzel ® , and ceramic<br />

Flow Diagram<br />

Analytical Sample Injectors<br />

Description Version Part No.<br />

7725, Includes a 20µL PEEK Sample Loop SS 77250<br />

7725i, Includes a 20µL PEEK Sample Loop SS 77251<br />

9725, Includes a 20µL PEEK Sample Loop PEEK 40010<br />

9725i, Includes a 20µL PEEK Sample Loop PEEK 40011<br />

Accessories<br />

Suction Needle Adapter — 40016<br />

5503<br />

Waste<br />

6<br />

1<br />

5<br />

2<br />

4<br />

Pump 3<br />

Column<br />

Waste<br />

6<br />

Sample In 1<br />

5<br />

Sample In<br />

2<br />

4<br />

Pump 3<br />

Column<br />

Position A (LOAD) Position B (INJECT)<br />

5502<br />

Analytical Sample Injectors<br />

Description Version Part No.<br />

7125 SS 7125RV<br />

Accessories<br />

Suction Needle Adapter — 40016<br />

5500<br />

Rheodyne ® Model 7010 and 9010 Analytical Injectors<br />

• Rear-loading valves<br />

• High volumetric precision<br />

• Low volume flow passages<br />

• Loop-Filler Port accommodates needles from 0.018" to<br />

0.028" diameter<br />

The 7010 injects sample volumes of 5µL or larger by means<br />

of a removable sample loop. Functionally similar to the 7010,<br />

the 9010 is more inert, made from PEEK, Tefzel ® and ceramic.<br />

The 9010 comes with a built-in position-sensing switch.<br />

Loop Filler Port<br />

Accessory<br />

Analytical Sample Injectors<br />

Description Version Part No.<br />

7010, Includes a 20µL Sample Loop SS 7010RV<br />

9010, Includes a 20µL Sample Loop PEEK 9000RV<br />

Accessories<br />

Loop-Filler Port SS 7044<br />

Loop-Filler Port PEEK 40012<br />

Needle Port Fitting — 7012-009<br />

5501<br />

136 www.discoverysciences.com


analytical hplc<br />

Rheodyne ® Model 8125<br />

Micro-Scale Injector<br />

• Versatile!—Works with microbore (1–2mm i.d.) and<br />

analytical (2–6mm i.d.) columns<br />

• Low dispersion 0.25mm flow passages<br />

• Built-in position-sensing switch<br />

Rheodyne ® Model 7410<br />

Micro-Scale Injector<br />

• High volumetric precision<br />

• 0.5µL to 2µL removable internal sample loops<br />

• Designed for 1–2mm i.d. columns<br />

The 8125 valve has unique “dual size” ports for tubing<br />

connections. This allows either 1/16" o.d. or 0.02" o.d. tubing<br />

to be used. Connections to 1/16" column endfittings are<br />

facilitated with a connecting tube supplied with the valve.<br />

The smaller flow passages also result in more resistance to<br />

flow. This makes it harder to load large sample volumes. The<br />

maximum recommended sample volume for the 8125 valve is<br />

500µL. All sample loops are externally plumbed.<br />

5498 5499<br />

Rheodyne ® Model 7410 Sample Injection Valve is a single<br />

mode injector whereby sample is loaded with the complete<br />

filling method using a loop-filler port. This injector can be used<br />

with Rheodyne ® loop-filler port accessories, position sensing<br />

switches, and mounting panels.<br />

The valve has four ports which are threaded to accept<br />

Rheodyne ® male nuts and ferrules (compression-type tube<br />

fittings) for 1/16" o.d. stainless steel tubing.<br />

hplc accessories | valves<br />

Micro-Scale Sample Injector<br />

Description Version Part No.<br />

8125 SS 8125RV<br />

Micro-Scale Sample Injector<br />

Description Version Part No.<br />

7410 SS 7410RV<br />

Accessories<br />

0.5µL Loop Disc — 7410-070<br />

1µL Loop Disc — 7410-071<br />

2µL Loop Disc — 7410-072<br />

related products<br />

Need sample loops and fittings for your<br />

Rheodyne ® injector?<br />

For sample loops, see page 140.<br />

For fittings, see page 141.<br />

related products<br />

Did you know that <strong>Grace</strong> has a complete offering of nano,<br />

capillary, and microbore columns for both small and<br />

large molecule applications? See page 31 for explanation<br />

of hardware formats and see pages 24 and 25 for phase<br />

descriptions.<br />

5640<br />

6950<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

6951<br />

www.discoverysciences.com<br />

137


analytical hplc<br />

Rheodyne ® Manual Switching Valves<br />

• Inexpensive manual switching valve<br />

• Wide-bore version for prep<br />

Manual Switching Valve Applications<br />

2-Position 6-Port:<br />

Two Column Selection<br />

2-Position 6-Port:<br />

Pre-Column Backflushing<br />

Injector<br />

Injector<br />

hplc accessories | valves<br />

Rheodyne ® HPLC Switching Valves offer an endless variety of<br />

ways to simplify switching and injecting. Standard valves are<br />

supplied with 0.024" internal flow passages and are suitable<br />

for use with analytical and semi-preparative applications.<br />

Large bore valves with 0.040" internal flow passages are<br />

available for use at high flow rates (greater than 50mL/min)<br />

7000psig pressure limit.<br />

A spring detent mechanism included in the 6-position<br />

selection valve permits full circle rotation in either direction<br />

and ensures that the rotor “falls into” each of the six positions<br />

at the precise 60° spacing.<br />

*5000psig pressure rating for 2-position 6-port and 10-port.<br />

5619<br />

6<br />

1<br />

5 4<br />

Detector<br />

2<br />

3<br />

0798<br />

Off line column is sealed. Flow<br />

continues on line.<br />

3-Way Valve:<br />

Column Programming<br />

Analytical Column<br />

6<br />

1<br />

2<br />

5 4<br />

3<br />

Detector<br />

Pre Column<br />

0801<br />

Flow continues through column.<br />

Only pre-column is backflushed.<br />

4-Way Valve:<br />

Column Backflushing<br />

Rheodyne ® Manual Switching Valves<br />

Description Version Bore Part No.<br />

2-Position Valves<br />

6-Port SS Standard 7000RV<br />

6-Port SS Large Bore 7000L<br />

3-Way SS Standard 7030RV<br />

3-Way SS Large Bore 7030L<br />

4-Way SS Standard 7040RV<br />

Multi-Position Valves<br />

6-Position 6-Port SS Standard 7060RV<br />

Column B<br />

Column A<br />

6<br />

1<br />

2<br />

5 4<br />

Detector<br />

3<br />

Injector<br />

Column C<br />

6<br />

1<br />

2<br />

5 4<br />

Detector<br />

3<br />

Injector<br />

0802<br />

0800<br />

related products<br />

Need fittings for valves? See page 141.<br />

Part of sample is analyzed on<br />

columns A-B, the other part on<br />

columns A-C.<br />

Flow is backflushed to direct<br />

peak of interest to detector.<br />

6-Position 6-Port Valve:<br />

Tandem Five Column Selection<br />

Detector<br />

5<br />

4<br />

6<br />

3<br />

1<br />

2<br />

5<br />

4<br />

6<br />

3<br />

1<br />

2<br />

Injector<br />

Bypass Flush-Out Line<br />

Selects between five columns. Use the sixth port for a bypass/flush<br />

out line. Two 7060s are required.<br />

0799<br />

138 www.discoverysciences.com


analytical hplc<br />

Rheodyne ® RheBuild ® Kits<br />

for Injection Valves<br />

• Contains everything necessary for valve maintenance<br />

• Conveniently packaged according to valve model<br />

• Economical—Save over buying individual replacement<br />

parts<br />

Rheodyne ® Replacement<br />

Parts<br />

Knob Assembly<br />

Set Screws (2)<br />

Needle Guide<br />

Shaft Assembly<br />

Body<br />

RheBuild ® Kits contain a complete assortment of all the parts<br />

you need for general valve maintenance. In addition to the<br />

genuine Rheodyne ® parts selected for your specific valve,<br />

detailed instructions guide you through the repair process.<br />

5777<br />

Spring Washers (4)<br />

Needle Port Tube Assembly<br />

Isolation Seal<br />

Thrust Bearing<br />

Rotor Pin<br />

Seal Pins (4)<br />

Bearing Ring<br />

Rotor Seal (Vespel)<br />

Stop Pins (2)<br />

Stator Ring<br />

Stator Face Assembly<br />

Stator Set Screws (3)<br />

Stator<br />

Stator Screws<br />

0818<br />

hplc accessories | valves<br />

Rheodyne ® RheBuild ® Kit Specifications<br />

Model<br />

Includes:<br />

3725, 3725i, 3725-038, 3725i-038, Standard Rotor Seal, Stator Face<br />

7125, 7126, 7125-081, 7725, 7725i, Assembly, Isolation Seal, Needle<br />

7726, 8125, 8126, 9125, 9126, 9725, Guide, Needle Port Cleaner, 2 Hex<br />

9725i, 9726<br />

Keys, and Instructions<br />

7520, 7526 Inlet Stator, Rotor, Needle Guide,<br />

Needle Port Cleaner, Hex Key, Rotor<br />

Removal Tool, and Instructions<br />

7010, 7000, 7410, 9010, 9040 Standard Rotor Seal, Isolation Seal,<br />

2 Hex Keys, and Instructions<br />

Rheodyne ® RheBuild ® Kits<br />

Description<br />

Part No.<br />

3725, 3725i, 3725-038, 3725i-038 10455<br />

7125, 7126 10457<br />

7125-081 10459<br />

7725, 7725i, 7726 10461<br />

8125, 8126 10463<br />

9125, 9126 10465<br />

9725, 9725i, 9726 10467<br />

7520, 7526 10469<br />

7010, 7000 10471<br />

7410 10473<br />

9010, 9040 10474<br />

Replacement Parts for Rheodyne ® Injectors<br />

Description Qty. Part No.<br />

Isolation Seal for All Valves ea 7010-015<br />

Stator Screw for 7010 10 77514<br />

Rotor Seal for 7010 ea 7010-039<br />

Stator for 7010/7125 ea 7010-040<br />

Stator for 7060 ea 7060-039<br />

Needle Guide for 7125/7725/7725i/8125/9125 ea 7125-008<br />

Knob Assembly for 7125 ea 7125-043<br />

Rotor Seal for 7125/7126/7725/7725i ea 7125-047<br />

PEEK Rotor Seal for 9010 ea 9010065<br />

Tefzel ® Rotor Seal for 9010 ea 90100510<br />

Stator Face Assembly for 7125 ea 7125-067<br />

Rotor Seal for 7410 ea 7410-038<br />

Rotor Seal for 7413 ea 7413-013<br />

Stator for 7725/7725i ea 7725010<br />

Stator Face Assembly for 7725/7725i ea 77250260<br />

Rotor Seal (Vespel) for 8125 ea 8125038<br />

Stator Face Assembly for 8125 ea 8125-074<br />

Stator Face Assembly for 9125 ea 8125-094<br />

Stator for 9125 ea 9125-036*<br />

Tefzel ® Rotor Seal for 9125 ea 9125-082<br />

PEEK Rotor Seal for 9125 ea 9125-095<br />

Tefzel ® Rotor Seal for 9010 ea 9010065<br />

*Includes ring.<br />

www.discoverysciences.com<br />

139


analytical hplc<br />

hplc accessories | valves<br />

Rheodyne ® Sample Loops<br />

Metal Sample Loops<br />

• Square cut and burr free<br />

tubing for flush connection<br />

to the valve<br />

• Includes unswaged fittings<br />

and ferrules<br />

• Coiled and configured for<br />

specific valves<br />

Rheodyne ® metal sample loops<br />

are available in 316 stainless steel<br />

or titanium. Actual volumes can differ due to the tolerances of<br />

the tubing. Precise volumes may be injected by the “partialfilling”<br />

method if you are using a dual-mode injector.<br />

Metal-Free Sample Loops<br />

• PEEK construction is inert and biocompatible<br />

• Flexible tubing makes them<br />

easy to use<br />

• Includes versatile RheFlex ®<br />

fittings<br />

PEEK sample loops are a<br />

convenient alternative to<br />

stainless steel. Actual sample<br />

loop volume can differ from<br />

theoretical designations due to<br />

the ±0.05mm tolerances on the<br />

tubing bore.<br />

Sample Loops—Analytical Injectors<br />

Metal<br />

7725/7725i<br />

Part No.<br />

Metal<br />

7125/7010<br />

Part No.<br />

Metal<br />

8125/8126<br />

Part No.<br />

PEEK<br />

9000/9725<br />

Part No.<br />

Description<br />

2µL (Internal) 7725015 — — —<br />

5µL 7725020 70-20SL 802001 9055020<br />

10µL 7725021 70-21SL — 9055021<br />

20µL 7725022 70-22SL — 9055022<br />

50µL 7725023 70-23SL — 9055023<br />

100µL 7725024 70-24SL 7725024 9055024<br />

200µL 7725025 70-25SL 7725025 9055025<br />

500µL 7725026 70-26SL 7725026 9055026<br />

1mL 7725027 70-27SL 7725027 9055027<br />

2mL 7725028 70-28SL 7725028 9055028<br />

5mL 7725029 70-29SL 7725029 9055029<br />

5641<br />

2745<br />

5640<br />

related products<br />

The Handy-Lok Fitting Wrench<br />

has a slotted design which<br />

fits conveniently around the<br />

connecting tubing, and grips the<br />

entire hex securely. This gives<br />

you better access to fittings<br />

in awkward or obstructed<br />

locations, such as the back<br />

of an injection valve.<br />

See page 393 to order the<br />

Handy-Lok Fitting Wrench.<br />

Alltech ® Sample Loops<br />

Flex-Connect Sample Loops<br />

• Flexible coil bends into place<br />

quickly and easily<br />

• Includes universal fittings that<br />

prevent dead volume<br />

• 100% PEEK construction—<br />

prevents corrosion and sample loss<br />

Two-piece Ferrule Does Not<br />

Twist Tubing<br />

PEEK Flex-Connect Sample Loops<br />

Description Qty. Part No.<br />

Flex-Connect Sample Loop with Hex-Head Nuts and a Two-piece Ferrule<br />

5µL ea 32194<br />

10µL ea 32196<br />

20µL ea 32195<br />

50µL ea 32202<br />

100µL ea 32204<br />

200µL ea 32206<br />

500µL ea 32210<br />

1mL ea 32222<br />

Fittings (PEEK)<br />

Short Hex-Head Nut and Ferrule 5 32215<br />

Long Hex-Head Nut and Ferrule 5 32217<br />

Two-Piece Ferrule 5 32218<br />

1086<br />

Stainless Steel Sample Loops<br />

• Includes finger-tight fittings that<br />

require no wrenches<br />

• PEEK ferrule automatically adjusts<br />

to port dimensions<br />

• Leak-proof to 5000psig<br />

• Stainless steel loop, PEEK ferrule<br />

Flexible Coil<br />

Stainless Steel Sample Loops<br />

Description Qty. Part No.<br />

5µL Sample Loops ea 32101<br />

10µL Sample Loops ea 32105<br />

20µL Sample Loops ea 32109<br />

50µL Sample Loops ea 32113<br />

100µL Sample Loops ea 32119<br />

200µL Sample Loops ea 32122<br />

Sample Loop Kit<br />

Includes: 1 each of above Loops,<br />

ea 32125<br />

12 PEEK Ferrules<br />

Fittings<br />

Long Stainless Steel Nut 5 321025<br />

Short Stainless Steel Nut 5 321185<br />

PEEK Ferrules 5 321805<br />

0813<br />

5642<br />

140 www.discoverysciences.com


analytical hplc<br />

Rheodyne ® ChromTRAC <br />

Fitting System<br />

• Allows hex-head fittings to be finger-tightened<br />

• Color code fluid lines<br />

• Fits tightly atop any Alltech ® or Rheodyne ® hex-head<br />

10-32 fitting<br />

ChromTRAC ID Kit<br />

Description Qty. Part No.<br />

ID Kit* 20/pk 6002830<br />

*Four each of blue, red, yellow; two each of grey, green, white, black.<br />

Rheodyne ® RheFlex ® PEEK Fittings with ChromTRAC<br />

One-Piece<br />

Part No.<br />

Two-Piece<br />

Part No.<br />

5379<br />

Two-Piece<br />

Extra-Long<br />

Part No.<br />

Color<br />

Qty.<br />

Qty.<br />

Qty.<br />

RheFlex ® Fittings with ChromTRAC<br />

Blue 10 6002821 5 6005401 — —<br />

Grey 10 6002822 5 6005402 1 6006602<br />

White 10 6002823 5 6005403 1 6006603<br />

Green 10 6002824 5 6005404 1 6006604<br />

Red 10 6002825 5 6005405 1 6006605<br />

Yellow 10 6002826 5 6005406 1 6006606<br />

Black — — 5 6000054 1 6006608<br />

Multicolor* 10 6002827 — — — —<br />

*Includes two each of blue, grey, green, red, yellow.<br />

Valve Mounting Brackets<br />

Rheodyne ® Mounting Panels<br />

Aluminum mounting plates are drilled<br />

with the appropriate holes for attaching<br />

all Rheodyne ® high-pressure valves. A<br />

hole is included for the Model 7012 Loop-<br />

Filler Port. The flat panel (1.57 x 5.12",<br />

4 x 13cm) has valve mounting holes at<br />

one end and panel mounting holes at the<br />

other. The angled panel (2.5 x 2.5 x 2.3",<br />

6.4 x 6.4 x 5.9cm) is shown above.<br />

Rheodyne ® Valve Mounting Panels<br />

Description<br />

Part No.<br />

Mounting Panel<br />

7160RV<br />

Angle Mounting Bracket 7160-010<br />

Alltech ® Ring Stand Brackets<br />

These sturdy brackets allow<br />

Rheodyne ® or Valco ® HPLC<br />

valves to be securely mounted<br />

to standard laboratory ring<br />

stands. The dimensions for<br />

the mounting bracket are<br />

1.5 x 2.5 x 4.5" (3.8 x 6.4 x 11.4cm).<br />

Alltech ® Ring Stand Brackets for HPLC Valves<br />

Description<br />

Part No.<br />

Mounting Bracket 9540<br />

tech tip<br />

What Is the correct way to plumb a valve?<br />

5623<br />

5624<br />

hplc accessories | valves<br />

Rheodyne ® RheFlex ® Fittings<br />

A<br />

E<br />

B<br />

H<br />

0808,1886-1888<br />

Rheodyne ® RheFlex ® Fittings<br />

Graphic Description Qty. Part No.<br />

RheFlex ® Stainless Steel Fittings with Ferrules<br />

A Nut 10 77510<br />

B Long Nut 10 77512<br />

C Extra Long Nut 10 77519<br />

D Replacement Ferrules 10 77511<br />

RheFlex ® PEEK Fittings with Ferrules<br />

E RheFlex ® Fitting 5 6000054<br />

F Short RheFlex ® Fitting 5 6000055<br />

G Replacement Ferrules 5 6000051<br />

RheFlex ® PEEK One-Piece Fingertights<br />

H RheFlex ® Fitting 10 600282<br />

F<br />

C<br />

D<br />

G<br />

Figure 1<br />

1. Make a burr-free square cut on any tubing that will be plumbed<br />

into the valve. This ensures the tubing will “bottom out” in<br />

the valve port. If tubing does not “bottom out”, a cavity will<br />

form which leads to peak distortion such as fronting, tailing<br />

or broadening.<br />

2. Place a nut and ferrule on the tubing<br />

3. Insert tubing into the valve port. Confirm that the tubing is<br />

bottomed in the valve port as shown in Figure 1.<br />

4. While firmly pressing the tubing, finger-tighten the nut as much<br />

as possible. For hex-head fittings, use a wrench to turn the<br />

fitting another 1/4 to 1/2 turn past finger-tight.<br />

0629<br />

www.discoverysciences.com<br />

141


analytical hplc<br />

hplc accessories | valves<br />

Alltech ® SelectPRO Automated Switching Valves<br />

• Increase productivity<br />

• Save time with unattended operation<br />

• Available in stainless steel or PEEK<br />

SelectPRO valve systems are electronically-controlled<br />

instruments. They increase productivity and save time and<br />

money by eliminating repetitive, manual switching. Now you<br />

can automate a wide variety of fluid-processing applications<br />

such as methods development, solvent switching, sample<br />

preconcentration, and fraction collection.<br />

SelectPRO valve position is always indicated by a digital<br />

display on the front panel. Operation is easy with manual<br />

switching on the front panel or automated switching with<br />

a built-in electronic communication interface. Automated<br />

control through the communication interface is accomplished<br />

by either level logic (2-position) or four-line BCD (multiposition)<br />

control. All line controls require contact closure<br />

or TTL outputs.<br />

SelectPRO Automated Switching Valves Specifications<br />

Dimensions:<br />

5.5" H x 3.0" W x 7.5" D<br />

(14cm H x 76cm W x 19.1cm D)<br />

Maximum Pressure:<br />

5000psig (345 bar)*<br />

Warranty:<br />

1 Year<br />

2-Postion Valve Control:<br />

Level Logic<br />

Multi-Position Valve Control: 4-Line BCD<br />

Supplied With:<br />

Interface Cable and Universal Power<br />

Supply<br />

*Maximum pressure for 6-position solvent selector is limited by 1/4-28 fittings.<br />

SelectPRO TM Switching Valve Applications<br />

2-Postition, 10-Port: On-line sample enrichment to<br />

decrease total analysis time<br />

2-Channel Selector with By-Pass: Reduce equilibration<br />

time during solvent changeover between two columns<br />

4108<br />

Alltech ® SelectPRO Automated Switching Valves<br />

Description Version Part No.<br />

2-Position Valves<br />

6-Port SS 85521<br />

10-Port SS 85531<br />

6-Port PEEK 85525<br />

10-Port PEEK 85535<br />

Multi-Position Valves<br />

2-Channel Selector By-Pass SS 85563<br />

2-Channel Selector By-Pass PEEK 85567<br />

10-Position Selector SS 85583<br />

10-Position Selector PEEK 85587<br />

6-Position Solvent Selector, 1/16" † SS 85593<br />

6-Position Solvent Selector, 1/8" † SS 85597<br />

SelectPRO Valve RheBuild ® Kits<br />

For 2-Position, 6-Port** 85529<br />

For 2-Position, 10-Port** 85539<br />

For 2-Channel Selector with By-Pass** 85569<br />

For 10-Position Selectors** 85589<br />

For 1/16" Tubing, 6-Position Solvent<br />

85594<br />

Selectors<br />

For 1/8" Tubing, 6-Position Solvent Selectors 85599<br />

**Suitable for Stainless Steel or PEEK version.<br />

†<br />

Low pressure valve uses 1/4-28 fittings.<br />

10-Position Selector: Select ten columns using two<br />

valves to accelerate methods development<br />

6-Position Solvent Selector: Select various mobile<br />

phase compositions for method development.<br />

4107<br />

4109<br />

related products<br />

Refer to page 141 for Rheodyne ® fittings.<br />

4110<br />

142 www.discoverysciences.com


analytical hplc<br />

Alltech ® SelectPRO Column Selector<br />

• Streamline method development and validation<br />

• Screen multiple HPLC columns quickly<br />

and automatically<br />

• Eliminate sample carry-over and minimize dispersion with<br />

low dead-volume valve architecture<br />

The Alltech ® SelectPRO TM Column Selector is a self-contained,<br />

electrically operated instrument for automated column<br />

selection. A SelectPRO TM Column Selector is a powerful tool<br />

for quickly screening multiple columns for the best separation.<br />

After column selection and method optimization is achieved,<br />

use the column selector to quickly validate methods using<br />

different lots of the same packing material or, alternatively,<br />

different columns from the same lot.<br />

Many laboratories have a number of users sharing the<br />

same system. The column selector lets multiple users select<br />

methods using the correct column for their assay and offers<br />

convenient washout and column storage. Different samples<br />

can be run at night and over weekends using different<br />

methods, better utilizing existing equipment and increasing<br />

productivity.<br />

The selected column is indicated by a bright digital display<br />

on the front panel. Select columns remotely using 4-line BCD<br />

electronic interface, or locally by push button.<br />

Design Features:<br />

• Pinch clips simplify column mounting and removal<br />

• Built-in drip tray provides safe and convenient solvent<br />

containment for leaks and spills<br />

• Magnetically secured cover maintains environmental<br />

isolation and stabilizes ambient temperature<br />

• Side tubing fasteners organize tubing connections<br />

• Accommodates columns in lengths of 3–35cm<br />

(2–14") and diameters of 0.6–3.2cm (0.25–1.25")<br />

Column Selector<br />

Pump<br />

1.00<br />

Column 5<br />

Column 6<br />

4534 4535<br />

Column 4<br />

Column 3<br />

6<br />

Sample Injector<br />

Column 2<br />

In<br />

Column 1<br />

4<br />

5<br />

Column Selector<br />

with Cover<br />

3<br />

2<br />

1<br />

Out<br />

1 ı 3ı 5 ı<br />

Detector<br />

2 ı 6 ı<br />

4 ı<br />

hplc accessories | valves<br />

SelectPRO Column Selector Specifications<br />

Dimensions:<br />

22" H x 9.8" W x 12.8" D<br />

(55.9cm H x 24.9cm W x 32.5cm D)<br />

Maximum Pressure: 5000psig (345 bar)<br />

Flow Passage: 0.6mm (0.024") and 0.4mm (0.015")<br />

Environment:<br />

Supplied with:<br />

Warranty:<br />

Control:<br />

4–40°C,


analytical hplc<br />

ASI QuickSplit Flow Splitters<br />

Post-Column Fixed Splitters<br />

Post-Column Adjustable Splitters<br />

hplc accessories | valves<br />

• Easy-to-use “plug and play” device<br />

• Predefined split ratio eliminates tedious<br />

adjustments to capillary tubing<br />

• Ultra-low dead volume as small<br />

as 100nL<br />

• Interchangeable fluid resistors create<br />

split ratios from 1:1 to 2000:1<br />

ASI Post-Column Fixed Flow Splitters provide a fixed<br />

split ratio with extremely low dead volume—as low as<br />

100 nanoliters, depending upon the resistor cartridge.<br />

Split ratios are unaffected by solvent viscosity or pressure<br />

changes, and are extremely stable and reproducible. Ultra<br />

low internal volume means that solvent composition in both<br />

resistors at the same time is identical, and therefore viscosity<br />

changes associated with gradient runs do not impact the<br />

split ratio. These splitters have an input flow range from<br />

0.1 to 5mL/min.<br />

Post-Column Fixed Flow Splitters and Replacement Resistor Sets<br />

Splitter<br />

Part No.<br />

Replacement Resistor Set<br />

Part No.<br />

Ratio<br />

2000:1 620103 6200103<br />

1000:1 620104 6200104<br />

500:1 620105 6200105<br />

200:1 620106 6200106<br />

100:1 620107 6200107<br />

50:1 620108 6200108<br />

20:1 620109 6200109<br />

10:1 620010 6200110<br />

5:1 620011 6200111<br />

3:1 620012 6200112<br />

1:1 620013 6200113<br />

6793<br />

• Adjustable flow splitter enables direct<br />

real time control over split ratio<br />

optimization<br />

• Create split ratios from 1:1 to 1000:1<br />

• Ultra low 0.5µL delay volume on<br />

capillary side<br />

• Easy to use interchangeable fluid<br />

resistors create a wide range of split ratios<br />

The flow path of the ASI post-column Adjustable Flow Splitter<br />

contains two fluid resistors that form a parallel flow path. The<br />

low flow rate stream passes through a fixed resistor cartridge,<br />

while the high flow rate stream passes through an adjustable<br />

fluid resistor (metering valve). The ratio of these two resistors<br />

creates the split flow ratio. Due to the rugged design, the split<br />

ratio repeatability is ±1% of setting, and unlike alternative<br />

splitter valves or tees, will not be affected by actions that<br />

effect input flow such as turning the pump off and on, or<br />

pressure spikes.<br />

Because the Adjustable Flow Splitter incorporates a<br />

metering valve, split ratios can be changed frequently with<br />

flow changes that are stable and reproducible. This provides<br />

direct real time control over split ratio optimization. Split ratios<br />

are not affected by changes in solvent viscosity or pressure.<br />

These splitters have an input flow range from 0.1 to 5mL/min.<br />

ASI Post-Column Adjustable Flow Splitters<br />

Description<br />

Part No.<br />

ASI Post-Column Adjustable Flow Splitters<br />

Adjustable from 50:1 to 1000:1 60201<br />

Adjustable from 15:1 to 250:1 60203<br />

Adjustable from 5:1 to 100:1 60204<br />

Adjustable from 1:1 to 20:1 60206<br />

Replacement Resistor Cartridges<br />

For 50:1 to 1000:1 601101<br />

For 15:1 to 250:1 601103<br />

For 5:1 to 100:1 601104<br />

For 1:1 to 20:1 601106<br />

6328<br />

ASI QuickSplit Makeup-Flow Splitter Manifold<br />

• Add makeup-flow to predetermined post column splits<br />

• Built-in delay time ensures proper sequencing between<br />

detector and fraction collector<br />

• Extremely low peak dispersion<br />

This splitter manifold is designed for post-column applications<br />

where a small amount of flow from an HPLC column is<br />

combined with a makeup-flow before it reaches the detector.<br />

A common application that uses this device involves splitting<br />

a small portion of the outlet flow from a preparative HPLC<br />

column which is then combined and diluted with a makeupflow.<br />

This flow is sent to a mass spec or UV to trigger a<br />

fraction collector from the remaining flow.<br />

Makeup-Flow Splitter Manifold<br />

Flow Range Split Ratio Part No.<br />

1–20mL/min 1000:1 620014<br />

20–50mL/min 10,000:1 620015<br />

50–150mL/min 5000:1 620016<br />

Replacement Resistor Cartridges<br />

1–20mL/min 1000:1 620017<br />

20–50mL/min 10,000:1 620018<br />

50–150mL/min 5000:1 620019<br />

144 www.discoverysciences.com


analytical hplc<br />

Hamilton ® Miniature Inert<br />

Low-Pressure Valves<br />

• Inexpensive low-pressure injection valves<br />

• Convenient solvent selection<br />

• Variety of flow configurations<br />

• Available in standard or panel mount<br />

Hamilton ® low-pressure valves provide an economical and<br />

flexible method of custom-building a fluid flow control system<br />

from a simple on/off valve to more complex multi-valve<br />

arrangement. The small valve body and inert flow path is<br />

suited for any low-pressure system. Three body styles are<br />

available. The HV is a stand alone manual valve. The HVP is<br />

the same as the HV valve except that it is panel mountable.<br />

The HVX is panel mountable and has a larger internal<br />

diameter of high flow or viscous fluids.<br />

5505 5668 5669<br />

HV Valve HVP Valve HVX Valve<br />

Hamilton ® Miniature Inert Valves Specifications<br />

Material:<br />

PTFE, Kel-F ® flow path<br />

Temperature Range: 10–100ºC<br />

Maximum Pressure: 100psig<br />

Thread Type: 1/4-28<br />

Port Orifice:<br />

0.059" for HV and HVP. 0.118" for HVX<br />

Hamilton ® Plug Types<br />

90, 180, T, 4-Port: Flow path connects two or more side ports<br />

Distribution:<br />

Flow path connects bottom port to any one side<br />

port<br />

Injection:<br />

Flow path connects pairs of adjacent ports<br />

hplc accessories | valves<br />

5597<br />

5599<br />

5600<br />

5601<br />

5603<br />

5604<br />

5605<br />

5606<br />

A<br />

B C D<br />

E F G H<br />

5607 5608 5609 5610<br />

5611<br />

5612<br />

5613<br />

I J<br />

K<br />

L<br />

M N O P<br />

5614<br />

Hamilton ® Miniature Inert Valves<br />

Graphic Housing Type Plug Type HV Part No. HVP Part No. HVX Part No.<br />

A 180° 180° 86725 86775* —<br />

B 90° 90° 86726 86776* —<br />

C “T” “T” 86727 86777* —<br />

D “T” 90° 86728 86778* —<br />

E 4-Port 4-Port 86729 86779* —<br />

F 4-Port “T” 86730 86780* —<br />

G 4-Port 90° 86731 86781* —<br />

H 4-Port 180° 86732 86782* —<br />

I 180° Distribution 86735 86785* —<br />

J 90° Distribution 86736 86786* —<br />

K “T” Distribution 86737 86787* —<br />

L 4-Port Distribution 86738 86788* —<br />

M 6-Port Distribution — — 86915 †<br />

N 6-Port Injection — — 86916 †<br />

O 8-Port Distribution — — 86918 †<br />

P 8-Port Injection — — 86919 †<br />

*HVP Valves require locking nut (Part No. 16450) for panel mounting.<br />

†<br />

HVX Valves require locking nut (Part No. 35121) for panel mounting.<br />

Valve Accessories<br />

Description<br />

Part No.<br />

Panel Mount Nut for HVP Valves 16450<br />

Panel Mount Nut for HVX Valves 35121<br />

Valve Adapters<br />

Description Material Part No.<br />

1/4-28 Male Thread to Hose Barb CTFE 350320<br />

1/4-28 Male Thread to Male Luer CTFE 35030<br />

1/4-28 Male Thread to Female Luer Lock CTFE 350310<br />

1/4-28 Male Thread to Male Luer Lock CTFE 350330<br />

1/4-28 Male Thread to RN Needle Adapter CTFE 350350<br />

www.discoverysciences.com<br />

145


analytical hplc<br />

SSI High-Pressure Needle Valves<br />

• Useful to aid in HPLC pump functions<br />

• Available in two-way and three-way configurations<br />

• Higher pressure limitations than other valves<br />

Fittings/Ferrules<br />

Description Qty. Part No.<br />

1/16" Gland Nut 10 01-0140<br />

1/16" Ferrule 10 01-0142<br />

Two-Way Valves<br />

Three-Way Valve<br />

hplc accessories | valves<br />

A<br />

0778 1763<br />

Two-Way Valve Specifications<br />

Material:<br />

PTFE, Tefzel ® , and 316 Stainless Steel<br />

Max Temperature: 100ºC<br />

Max Pressure:<br />

15,000psig<br />

Thread Type:<br />

1/16" SSI Fittings<br />

Typical Use:<br />

Basic shut-off valve with straight or<br />

angled ports<br />

B<br />

1<br />

3<br />

C<br />

2 3<br />

1<br />

1764<br />

Three-Way Valve Specifications<br />

Material:<br />

PTFE, Tefzel ® , and 316 Stainless Steel<br />

Max Temperature: 100ºC<br />

Max Pressure:<br />

15,000psig<br />

Thread Type:<br />

1/16" SSI Fittings<br />

Typical Use:<br />

Pressure venting to aid in pump priming,<br />

purging, or solvent changeover<br />

2<br />

D<br />

0780<br />

Two-Way Valves<br />

Graphic Description Part No.<br />

A Two-Way, Through Valve 02-0120<br />

B Two-Way, Angle Valve 02-0121<br />

Three-Way Valves<br />

Graphic Description Part No.<br />

C Three-Way, Bottom Vent 02-0124<br />

D Three-Way, Side Vent 02-0125<br />

Check Valves<br />

Prime/Purge Valves<br />

0781<br />

FLOW<br />

G<br />

E<br />

0782<br />

F<br />

0779<br />

Check Valve Specifications<br />

Material:<br />

PTFE, Chemraz ® , and 316 Stainless Steel<br />

Max Temperature: 100ºC<br />

Max Pressure:<br />

6000psig<br />

Thread Type:<br />

1/16" SSI Fittings<br />

Internal Volume 121µL<br />

Typical Use:<br />

Install as a back-up to inlet and outlet pump<br />

check valves to reduce pulsations in less<br />

sophisticated reciprocating pumps<br />

Check Valves<br />

Graphic Description Part No.<br />

G Check Valve 02-0129<br />

— Replacement Check Valve Seal 90-1001<br />

Prime/Purge Valve Specifications<br />

Material:<br />

PEEK or 316 Stainless Steel<br />

Max Temperature: 100ºC<br />

Max Pressure:<br />

6000psig<br />

Thread Type:<br />

Standard: 1/16" SSI fittings and 1/4-28 for<br />

low pressure side port<br />

Luer: 1/16" SSI fittings, and luer stem for<br />

low-pressure side port<br />

Typical Use:<br />

Low-pressure side port opens to prime and<br />

closes for normal use<br />

Prime/Purge Valves<br />

Graphic Description Material Part No.<br />

F Prime/Purge Valve, Luer Stem PEEK 060115<br />

F Prime/Purge Valve, Luer Stem SS 02-0292<br />

E Prime/Purge Valve, Standard SS 02-0191<br />

— Seal Kit for 02-0191 — 02-0194<br />

146 www.discoverysciences.com


Prep | Flash | TLC<br />

Preparative Chromatography . . . . . . . . 148–183<br />

Introduction. . . . . . . . . . . . . . . . . . . . . . 148–151<br />

Columns . . . . . . . . . . . . . . . . . . . . . . . 152–171<br />

<strong>Grace</strong>Alpha Columns 152–155<br />

Vydac ® MS Columns 156–157<br />

Vydac ® TP Columns 158–160<br />

Alltech ® Columns 161<br />

Column Hardware . . . . . . . . . . . . . . . . . . 162–171<br />

MODcol ® Spring Columns 162–165<br />

Axial SFC Column Hardware 166–169<br />

Empty MODcol ® Flanged Columns 170<br />

Process Scale Columns (Peak Biotech) 171<br />

Column Packing . . . . . . . . . . . . . . . . . . . 172–174<br />

MODcol ® Multipacker ® Packing Stations 172–173<br />

Column Packing Services 174<br />

Media . . . . . . . . . . . . . . . . . . . . . . . . 175–181<br />

Introduction 175<br />

<strong>Grace</strong>Alpha Media . . . . . . . . . . . . . . . . . . . . . . 176<br />

Vydac ® Media 177<br />

Davisil ® Media 178–181<br />

Accessories . . . . . . . . . . . . . . . . . . . . . 182–183<br />

Tubing, Fittings, Pumps, Injectors, and Swtching Valves<br />

Flash Chromatography . . . . . . . . . . . . 184–187<br />

Introduction. . . . . . . . . . . . . . . . . . . . . . . . 184<br />

<strong>Grace</strong>Resolv Flash Cartridges . . . . . . . . . . . 185–187<br />

Flash Accessories . . . . . . . . . . . . . . . . . . 186–187<br />

Flash Media . . . . . . . . . . . . . . . . . . . . . . . . 187<br />

Thin Layer Chromatography (TLC) . . . . . 188–198<br />

Introduction. . . . . . . . . . . . . . . . . . . . . . . . 188<br />

TLC Plates . . . . . . . . . . . . . . . . . . . . . . 189–193<br />

TLC Accessories . . . . . . . . . . . . . . . . . . . 194–198


prep | flash | tlc<br />

prep | columns<br />

Preparative Chromatography Introduction<br />

<strong>Grace</strong> ® Key Column Families<br />

Scalable Solutions: Silica and Hardware<br />

<strong>Grace</strong>, the foremost name in silica material science,<br />

manufactures a range of completely scaleable preparative<br />

chromatography columns. To help select the appropriate<br />

column for your application, we describe key column families<br />

and highlight unique phases within these families. Each<br />

column family highlighted is also scalable to bulk media and<br />

available in ton quantities for process scale applications.<br />

<strong>Grace</strong>’s silica based media is packed in proprietary column<br />

hardware that extends media lifetime and ensures high<br />

column efficiencies at the preparative scale. An overview<br />

of preparative column hardware can be found on pages<br />

150–151.<br />

<strong>Grace</strong>Alpha<br />

A New Silica Generation<br />

<strong>Grace</strong>Alpha combines increased column efficiencies<br />

and resolution with high loading capacity. A new silica<br />

(patent pending) makes this possible by combining a<br />

high-porosity surface, with a dense core, increasing<br />

mass transfer while yielding a mechanically robust<br />

particle.<br />

Column Packing and Operation<br />

It is generally accepted that the most reliable packing method<br />

for high-performance preparative columns involve axial<br />

compression of the adsorbent slurry in the column by a sliding<br />

piston driven by hydraulic or pneumatic force. However,<br />

reliable performance and maximum column life are obtained<br />

only if axial compression force is maintained continuously on<br />

the column bed during use. The patented MODcol ® Spring<br />

Column and MultiPacker ® instrument now make it easy and<br />

convenient for scientists to reproducibly pack any media in a<br />

completely portable dynamic axial compression column.<br />

Adsorbent Particle Sizes<br />

Because small-diameter narrow-particle-range adsorbents<br />

generally are expensive, it is more economical to use less<br />

expensive larger diameter materials in preparative columns.<br />

This is often possible because the objectives of preparative<br />

separations differ from those of analytical separations. Speed<br />

and sensitivity may be less important than product purity in<br />

preparative chromatography. This allows preparative columns<br />

to be operated at lower flow rates with gradient profiles altered<br />

in order to compensate for the less efficient mass transfer of<br />

larger adsorbent particles. To simplify method development<br />

and scale-up, <strong>Grace</strong> provides a range of adsorbent sizes and<br />

grades with identical bonded-phase chemistry.<br />

Applications: Peptides and small molecules<br />

(2000 molecular weight)<br />

Differentiated Phases: C18, C8, and C4<br />

Specifications: Spheroidal silica, polymerically and<br />

monomerically bonded, endcapped, 300Å pore size<br />

Formats: Capillary, LC/MS, Expedite, Rocket,<br />

Solvent-Reducer, Analytical, Prep, Bulk Media<br />

Peak Width at Half Height (mm)<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

15–20µm<br />

20–30µm<br />

5µm<br />

10µm<br />

0<br />

0 200 400 600 800 1000<br />

Ribonuclease Load (µg)<br />

7265<br />

Column Materials: Vydac ® 214TP, 5µm; Vydac ® 214TP, 10µm;<br />

Vydac ® 214TP, 15 –20µm;<br />

Vydac ® 214TP, 20 –30µm<br />

Eluent:<br />

24 – 95% ACN in 0.1% aqueous TFA over 30min<br />

at 1.5mL/min<br />

Protein:<br />

Ribonuclease<br />

148 www.discoverysciences.com


prep | flash | tlc<br />

Preparative Chromatography Introduction<br />

Preparative Scale Up<br />

Step 4: The Scale-up Factor<br />

The column size needed for the purification can be calculated<br />

based on the output requirements.<br />

D = diameter L = length<br />

Loadfinal = Loadinitial x (Dfinal)2 Lfinal<br />

(Dinitial) 2 Linitial<br />

The sample load scale-up equation determines the loading<br />

capacity of the larger preparative column from the loading<br />

capacity of the analytical column.<br />

Analytical<br />

(initial)<br />

Step 1: Method Optimization<br />

Prep<br />

(final)<br />

The analytical method is optimized to increase the alpha and<br />

achieve maximum loadability. The most common ways to<br />

optimize the method are through altering selectivity by mobile<br />

phase manipulation or by altering the stationary phase.<br />

Step 2: Loading Study<br />

Once the analytical method is developed the method<br />

loadability should be tested to determine the capacity of the<br />

stationary phase. The sample load will be determined by the<br />

complexity of the sample mixture as well as the stationary<br />

phase being used.<br />

Step 3: Mass Determination<br />

The total mass that is needed from the purification should<br />

be determined prior to starting the campaign. The total mass<br />

needed can be used to balance the necessary throughput,<br />

purity, and yield required from the separation.<br />

Step 5: Linear Velocity<br />

When the column dimensions are changed to optimize<br />

a separation, or to scale a separation to a preparative or<br />

narrow-bore application, the mobile phase flow rate should be<br />

adjusted proportionally to cross-sectional area of the column<br />

to maintain consistent linear velocity and retention times. See<br />

table below for common flow rate conversions (Table 1).<br />

Flow Ratefinal = Flow Rateinitial x (Dfinal)2<br />

(Dinitial) 2<br />

Step 6: Run Time and Gradient<br />

Run Time (prep) = Run Time (analytical) x L (analytical)/L (prep)<br />

The run time determined by the equation can be used to<br />

predict the elution time for the compound of interest. To<br />

retain the resolution obtained on an analytical column while<br />

increasing column diameter, the gradient shape must be<br />

maintained by keeping the ratio of the gradient volume to<br />

the column volume constant.<br />

prep | columns<br />

Table 1: Common Linear Scale-up Velocity Equivalencies<br />

Equivalent Linear Velocity Table Relative to 4.6mm i.d. Flow Rates<br />

Column Diameter (mm i.d.) 1.0 2.1 4.6 10.0 21.5 25 50 100<br />

Equivalent Flows (mL/min) 0.047 0.208 1.0 4.7 21.8 29.5 118 473<br />

Equivalent Flows (mL/min) 0.095 0.416 2.0 9.4 43.6 59.0 236 946<br />

Equivalent Flows (mL/min) 0.142 0.625 3.0 14.1 65.4 88.5 354 1,419<br />

related products<br />

For analytical HPLC columns,<br />

see pages 24–110.<br />

related products<br />

For flash cartridges,<br />

see pages 184–187.<br />

7110<br />

7278<br />

www.discoverysciences.com<br />

149


prep | flash | tlc<br />

Preparative Column Hardware<br />

<strong>Grace</strong> offers a variety of column formats to provide the best solution at each stage of scale-up.<br />

All of our columns employ radial flow slots to distribute sample and mobile phase evenly over the<br />

head of the column for sharp, narrow peaks. Each column is constructed with 316SS, is rated to<br />

2000psig and uses inert PTFE o-rings and seals.<br />

Unique radial flow slot design.<br />

Preparative Column Hardware<br />

Column Name Available Inner Diameters Attributes<br />

Prep Guard 7mm • Direct connect to Alltech ®<br />

Column<br />

brand columns<br />

prep | columns<br />

Prep Guard<br />

Cartridge<br />

new<br />

10, 20, 30mm • Holder and inexpensive<br />

replaceable cartridge<br />

protects and extends<br />

column lifetime<br />

Threaded Column 7, 10, 22mm • Packed under<br />

high pressure for<br />

high efficiency<br />

• Inexpensive<br />

and disposable<br />

Flanged Column 25, 30, 50, 100mm • Good flow distribution<br />

for excellent peak<br />

shape<br />

• Robust material of<br />

construction to enable<br />

repacking<br />

Spring Column 25, 50, 100mm • Dynamic axial<br />

compression for<br />

extended column<br />

lifetime<br />

• High efficiency<br />

best<br />

seller<br />

axial packing<br />

• Easily repacked<br />

Axial SFC Column 25, 50mm • Rated to 5000psig<br />

for use with SFC<br />

• High efficiency<br />

axial packing<br />

• Easily repacked<br />

tech tip<br />

30mm i.d. guards can be used with column i.d.s up to 50mm<br />

when packed with a larger particle size than the column<br />

being protected.<br />

related products<br />

Large process scale columns (DAC and<br />

flanged) up to 1 meter i.d. are available.<br />

See Peak Biotech columns on page 171<br />

for more information.<br />

150 www.discoverysciences.com


prep | flash | tlc<br />

Spring Column Overview<br />

Dynamic Axial Compression Column<br />

• Continuous axial compression prevents void formation,<br />

assures long column life<br />

• Use anywhere, just like a standard HPLC column<br />

• Packed under axial compression for high efficiency<br />

best<br />

seller<br />

The World’s Most Innovative Preparative Column<br />

Inside every Spring Column unit there is a mechanical<br />

spring that stores energy, maintaining axial compression<br />

force on the packed bed. This patented technology is the<br />

only mobile dynamic axial compression column available<br />

that prevents void formation. (U.S. Patents No. 5893971,<br />

5951873, 6036855).<br />

Spring Columns are available pre-packed with most <strong>Grace</strong> ®<br />

adsorbents. Spring Column hardware assures the longest<br />

column life and the best performance for your prepacked<br />

preparative column needs.<br />

<strong>Grace</strong> ® Multipacker ® packing stations together with empty<br />

Spring Column hardware provide the option of packing<br />

your own Spring Column units in house, with any<br />

high-performance preparative adsorbent of your choice.<br />

Multipacker ® stations are surprisingly affordable when<br />

compared to other axial compression packing systems and<br />

have the advantage of not requiring a dedicated packing<br />

station for each preparative HPLC location.<br />

related product<br />

Experience the cost savings and convenience of packing<br />

your own Spring Columns with the Multipacker ® instrument.<br />

See pages 172 and 173.<br />

more info<br />

For Spring Column ordering information, see pages 162–165.<br />

prep | columns<br />

Spring column Packing<br />

Step 1<br />

Slurry in column.<br />

Piston and compression<br />

mechanism in place.<br />

spring<br />

Step 2<br />

Apply axial compression<br />

force. Force compresses<br />

spring and moves piston<br />

to pack adsorbent bed.<br />

Step 3<br />

Lock compression<br />

mechanism. Remove<br />

external force. Spring<br />

remains compressed,<br />

maintains axial force on<br />

piston and packed bed.<br />

lock<br />

www.discoverysciences.com<br />

151


prep | flash | tlc<br />

<strong>Grace</strong>Alpha Columns<br />

A New Silica Generation<br />

new<br />

• High-porosity surface increases mass transfer and results<br />

in increased column efficiencies and loading capacity<br />

• Dense core and highly spherical shape yield<br />

mechanically robust particle<br />

• Proprietary bonding technology gives unique selectivity<br />

and increased resolution<br />

<strong>Grace</strong>Alpha Performance<br />

Outstanding Loading Capacity<br />

<strong>Grace</strong>Alpha silica has a high-porosity exterior yielding<br />

higher loading capacities than conventional silicas.<br />

Unique Selectivity<br />

Proprietary bonding chemistry provides unique selectivity that<br />

yields advantages not seen in other C18 and C8 phases.<br />

prep | columns<br />

Norm.<br />

800<br />

600<br />

400<br />

200<br />

Insulin Frontal Loading Capacity<br />

on C8 Columns with 0.1% TFA<br />

Insulin loading capacity is 16 to 1000% higher recovery on<br />

the <strong>Grace</strong>Alpha C8 column.<br />

Competitor A<br />

14 mg/mL<br />

Competitor B<br />

133 mg/mL <strong>Grace</strong>Alpha<br />

154 mg/mL<br />

Peptide Standard Mixture<br />

The <strong>Grace</strong>Alpha column offers selectivity advantages.<br />

1<br />

1<br />

2<br />

2<br />

3 4<br />

5<br />

3 4<br />

5<br />

<strong>Grace</strong>Alpha<br />

Column<br />

Competitor<br />

1. GY (238 Da)<br />

2. VYV (379 Da)<br />

3. Met Enkephalin<br />

(YGGFM, 573 Da)<br />

4. Angiotensin II<br />

(DRVYIHPF, 1045 Da)<br />

5. Leu Enkephalin<br />

(YGGFL, 555 Da)<br />

0<br />

0 20 40 60 80 100 120 140 160 180<br />

Breakthrough Time (min.)<br />

High Resolution and Recovery<br />

<strong>Grace</strong>Alpha columns increase purity and yield of synthetic<br />

peptides with superior resolution of impurities due to higher<br />

mass transfer and optimized C18 and C8 bonding chemistry.<br />

Crude 20-AA Synthetic Peptide<br />

The target peptide is better resolved from impurities, with<br />

33% higher recovery, on the <strong>Grace</strong>Alpha column.<br />

0 6 12 18 24 30 Min.<br />

Columns: All C18, 5µm, 4.6 x 250mm<br />

Mobile Phase: A: 0.1% TFA in Water, B: 0.085% TFA in Acetonitrile<br />

Gradient: Time: 0 30 35 40<br />

%B: 10 40 90 90<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 225nm<br />

Column Temp.: 25°C<br />

Resolution (USP)*<br />

Peptide Peak <strong>Grace</strong>Alpha Column Competitor<br />

1 42.0 35.7<br />

2 32.2 28.3<br />

3 6.0 2.3<br />

4 7.4 11.3<br />

*Resolution is based on the next adjacent peak.<br />

Better resolution<br />

of closely eluting<br />

impurities<br />

0.00 5.00 10.00 15.00 19.99<br />

Competitor<br />

Column 4µm<br />

<strong>Grace</strong>Alpha<br />

Column 5µm<br />

Columns: All C18, 4.6 x 250mm<br />

Mobile Phase: A: 0.1% TFA in Water, B: 0.1% TFA in Acetonitrile<br />

Gradient: Time: 0 20<br />

%B: 20 40<br />

Flow Rate: 1.0mL/min<br />

Data courtesy of: Biopeptide Inc.<br />

related products<br />

<strong>Grace</strong>Alpha bulk media is also<br />

available for scale-up. See page<br />

176 for more information.<br />

7250<br />

152 www.discoverysciences.com


prep | flash | tlc<br />

<strong>Grace</strong>Alpha Silica<br />

<strong>Grace</strong>Alpha (patent pending) is built on a completely<br />

new silica platform that incorporates over 80 years of<br />

silica technology at <strong>Grace</strong> to produce the ultimate in<br />

chromatographic performance.<br />

High-porosity exterior<br />

increases mass transfer.<br />

Extreme Porosity<br />

The base silica particle has an extremely high porosity at<br />

its surface that increases mass transfer leading to higher<br />

efficiencies and superior loading capacity. The high porosity<br />

structure has the increased benefit of adding an elastic quality<br />

to the silica surface allowing the particles to flex and exhibit<br />

a spring like effect when packed into a column. This further<br />

stabilizes the packed bed preventing voids from forming and<br />

allows the particles to pack tighter, yielding higher efficiencies<br />

in packed beds.<br />

Dense inner core provides<br />

exceptional strength<br />

Dense Core<br />

Typically the high porosity structure would result in a weak<br />

particle prone to breaking, but the <strong>Grace</strong>Alpha particle<br />

combines the high porosity outer region with a dense inner<br />

core that results in a particle that resists breaking and forming<br />

fines that contribute to high backpressures.<br />

<strong>Grace</strong>Alpha Silica Specifications<br />

Pore Size:<br />

120Å<br />

Pore Volume:<br />

0.95mL/g<br />

Surface Area: 325m 2 /g<br />

Chemical Purity:<br />


prep | flash | tlc<br />

prep | columns<br />

<strong>Grace</strong>Alpha Columns<br />

new<br />

<strong>Grace</strong>Alpha Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 5µm Analytical 4.6 x 150mm 5140743<br />

Analytical 4.6 x 250mm 5140702<br />

Prep—Threaded 10 x 150mm 5141840<br />

Prep—Threaded 10 x 250mm 5141841<br />

Prep—Threaded 22 x 50mm 5141773<br />

Prep—Threaded 22 x 100mm 5141842<br />

Prep—Threaded 22 x 150mm 5141843<br />

Prep—Threaded 22 x 250mm 5141845<br />

Prep—Spring 25 x 150mm 5142081<br />

Prep—Spring 25 x 250mm 5142082<br />

Prep—Flanged 30 x 50mm 5142497<br />

Prep—Flanged 30 x 100mm 5142501<br />

Prep—Flanged 30 x 150mm 5142504<br />

Prep—Flanged 30 x 250mm 5142507<br />

Prep—Spring 50 x 50mm 5142083<br />

Prep—Spring 50 x 100mm 5142085<br />

C18, 10µm Analytical 4.6 x 150mm 5140744<br />

Analytical 4.6 x 250mm 5140701<br />

Prep—Threaded 10 x 150mm 5141865<br />

Prep—Threaded 10 x 250mm 5140892<br />

Prep—Threaded 22 x 50mm 5141866<br />

Prep—Threaded 22 x 100mm 5141867<br />

Prep—Threaded 22 x 150mm 5141868<br />

Prep—Threaded 22 x 250mm 5141071<br />

Prep—Spring 25 x 150mm 5142086<br />

Prep—Spring 25 x 250mm 5142087<br />

Prep—Flanged 30 x 50mm 5142499<br />

Prep—Flanged 30 x 100mm 5142502<br />

Prep—Flanged 30 x 150mm 5142505<br />

Prep—Flanged 30 x 250mm 5142508<br />

Prep—Spring 50 x 50mm 5142088<br />

Prep—Spring 50 x 100mm 5142089<br />

Prep—Spring 50 x 150mm 5142090<br />

Prep—Spring 50 x 250mm 5142091<br />

Prep—Spring 100 x 50mm 5142093<br />

Prep—Spring 100 x 100mm 5142094<br />

Prep—Spring 100 x 150mm 5142095<br />

Prep—Spring 100 x 250mm 5142096<br />

C18, 15µm Analytical 4.6 x 150mm 5141058<br />

Analytical 4.6 x 250mm 5141059<br />

Prep—Threaded 10 x 150mm 5141860<br />

Prep—Threaded 10 x 250mm 5141861<br />

Prep—Threaded 22 x 50mm 5141862<br />

Prep—Threaded 22 x 100mm 5141863<br />

Prep—Threaded 22 x 150mm 5141864<br />

Prep—Threaded 22 x 250mm 5141070<br />

Prep—Spring 25 x 150mm 5142097<br />

Prep—Spring 25 x 250mm 5142098<br />

Prep—Flanged 30 x 50mm 5142464<br />

Prep—Flanged 30 x 100mm 5142503<br />

Prep—Flanged 30 x 150mm 5142506<br />

Prep—Flanged 30 x 250mm 5142500<br />

Prep—Spring 50 x 50mm 5142099<br />

Prep—Spring 50 x 100mm 5142100<br />

Prep—Spring 50 x 150mm 5142101<br />

Prep—Spring 50 x 250mm 5142102<br />

Prep—Spring 100 x 50mm 5142103<br />

Prep—Spring 100 x 100mm 5142104<br />

Prep—Spring 100 x 150mm 5142105<br />

Prep—Spring 100 x 250mm 5142106<br />

<strong>Grace</strong>Alpha Columns (continued)<br />

Packing Format i.d. x Length Part No.<br />

C8, 5µm Analytical 4.6 x 150mm 5140740<br />

Analytical 4.6 x 250mm 5140704<br />

Prep—Threaded 10 x 150mm 5141870<br />

Prep—Threaded 10 x 250mm 5141871<br />

Prep—Threaded 22 x 50mm 5141872<br />

Prep—Threaded 22 x 150mm 5141873<br />

Prep—Threaded 22 x 250mm 5141874<br />

Prep—Spring 25 x 150mm 5142107<br />

Prep—Spring 25 x 250mm 5142108<br />

Prep—Flanged 30 x 150mm 5142491<br />

Prep—Flanged 30 x 250mm 5142494<br />

Prep—Spring 50 x 50mm 5142109<br />

Prep—Spring 50 x 100mm 5142110<br />

C8, 10µm Analytical 4.6 x 150mm 5140742<br />

Analytical 4.6 x 250mm 5140703<br />

Prep—Threaded 10 x 150mm 5141876<br />

Prep—Threaded 10 x 250mm 5140891<br />

Prep—Threaded 22 x 50mm 5141878<br />

Prep—Threaded 22 x 150mm 5141879<br />

Prep—Threaded 22 x 250mm 5141880<br />

Prep—Spring 25 x 150mm 5142120<br />

Prep—Spring 25 x 250mm 5142121<br />

Prep—Flanged 30 x 150mm 5142492<br />

Prep—Flanged 30 x 250mm 5142495<br />

Prep—Spring 50 x 150mm 5142122<br />

Prep—Spring 50 x 250mm 5142123<br />

Prep—Spring 100 x 150mm 5142124<br />

Prep—Spring 100 x 250mm 5142125<br />

C8, 15µm Analytical 4.6 x 150mm 5141055<br />

Analytical 4.6 x 250mm 5141057<br />

Prep—Threaded 10 x 150mm 5141881<br />

Prep—Threaded 10 x 250mm 5141882<br />

Prep—Threaded 22 x 50mm 5141883<br />

Prep—Threaded 22 x 150mm 5141884<br />

Prep—Threaded 22 x 250mm 5141885<br />

Prep—Spring 25 x 150mm 5142128<br />

Prep—Spring 25 x 250mm 5142129<br />

Prep—Flanged 30 x 150mm 5142493<br />

Prep—Flanged 30 x 250mm 5142496<br />

Prep—Spring 50 x 150mm 5142130<br />

Prep—Spring 50 x 250mm 5142131<br />

Prep—Spring 100 x 150mm 5142132<br />

Prep—Spring 100 x 250mm 5142133<br />

related products<br />

20µm phases can be custom ordered packed in Spring columns<br />

or bulk media.<br />

154 www.discoverysciences.com


prep | flash | tlc<br />

<strong>Grace</strong>Alpha Columns<br />

<strong>Grace</strong>Alpha Columns<br />

Packing Format i.d. x Length Part No.<br />

Silica, 5µm Analytical 4.6 x 150mm 5142615<br />

Analytical 4.6 x 250mm 5142614<br />

Prep—Threaded 10 x 150mm 5142592<br />

Prep—Threaded 10 x 250mm 5142594<br />

Prep—Threaded 22 x 150mm 5142595<br />

Prep—Threaded 22 x 250mm 5142596<br />

Prep—Spring 25 x 150mm 5142663<br />

Prep—Spring 25 x 250mm 5142664<br />

Prep—Flanged 30 x 150mm 5142490<br />

Prep—Flanged 30 x 250mm 5142467<br />

Prep—Spring 50 x 50mm 5142665<br />

Prep—Spring 50 x 100mm 5142666<br />

Silica, 10µm Analytical 4.6 x 150mm 5142613<br />

Analytical 4.6 x 250mm 5142612<br />

Prep—Threaded 10 x 150mm 5142567<br />

Prep—Threaded 10 x 250mm 5142568<br />

Prep—Threaded 22 x 150mm 5142569<br />

Prep—Threaded 22 x 250mm 5142590<br />

Prep—Spring 25 x 150mm 5142667<br />

Prep—Spring 25 x 250mm 5142668<br />

Prep—Flanged 30 x 150mm 5142465<br />

Prep—Flanged 30 x 250mm 5142468<br />

Prep—Spring 50 x 150mm 5142669<br />

Prep—Spring 50 x 250mm 5142670<br />

Prep—Spring 100 x 150mm 5142671<br />

Prep—Spring 100 x 250mm 5142672<br />

Silica, 15µm Analytical 4.6 x 150mm 5142611<br />

Analytical 4.6 x 250mm 5142610<br />

Prep—Threaded 10 x 150mm 5142617<br />

Prep—Threaded 10 x 250mm 5142564<br />

Prep—Threaded 22 x 150mm 5142565<br />

Prep—Threaded 22 x 250mm 5142566<br />

Prep—Spring 25 x 150mm 5142673<br />

Prep—Spring 25 x 250mm 5142674<br />

Prep—Flanged 30 x 150mm 5142466<br />

Prep—Flanged 30 x 250mm 5142469<br />

Prep—Spring 50 x 150mm 5142675<br />

Prep—Spring 50 x 250mm 5142676<br />

Prep—Spring 100 x 150mm 5142677<br />

Prep—Spring 100 x 250mm 5142678<br />

Guard Cartridges and Holder<br />

Format i.d. x Length Qty. Part No.<br />

Prep—Guard Holder 10 x 10mm ea 2101342<br />

Prep—Guard Holder 20 x 10mm ea 3110650<br />

Prep—Guard Holder 30 x 30mm ea 3117320<br />

C18, 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 5142000<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 3118151<br />

Prep—Guard Cartridge 30 x 30mm ea 3118225<br />

C18, 10µm<br />

Prep—Guard Cartridge 10 x 10mm ea 5142001<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 3118220<br />

Prep—Guard Cartridge 30 x 30mm ea 3118226<br />

C18, 15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 5142002<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 3118221<br />

Prep—Guard Cartridge 30 x 30mm ea 3118227<br />

C8, 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 5142003<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 3118222<br />

Prep—Guard Cartridge 30 x 30mm ea 3118240<br />

C8, 10µm<br />

Prep—Guard Cartridge 10 x 10mm ea 5142004<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 3118223<br />

Prep—Guard Cartridge 30 x 30mm ea 3118241<br />

C8, 15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 5142005<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 3118224<br />

Prep—Guard Cartridge 30 x 30mm ea 3118242<br />

Silica, 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 5142616<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 3118620<br />

Prep—Guard Cartridge 30 x 30mm ea 3118622<br />

Silica, 10µm<br />

Prep—Guard Cartridge 10 x 10mm ea 5142617<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 3118623<br />

Prep—Guard Cartridge 30 x 30mm ea 3118624<br />

Silica, 15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 5142618<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 3118625<br />

Prep—Guard Cartridge 30 x 30mm ea 3118626<br />

prep | columns<br />

tech tip<br />

30mm i.d. guards can be used with column i.d.s up to 50mm<br />

when packed with a larger particle size than the column<br />

being protected.<br />

more info<br />

A guard holder must be purchased separately from the guard<br />

cartridge for first-time use. Guard holders can then be reused.<br />

www.discoverysciences.com<br />

155


prep | flash | tlc<br />

Vydac ® MS 300Å Columns<br />

High Protein Recovery<br />

• Unique Selectivity for exceptional resolution of proteins<br />

and peptides<br />

• High protein recovery improves yield<br />

A patented surface chemistry reduces adsorption of proteins<br />

on the silica surface which means higher recoveries and<br />

better resolution.<br />

Improved Resolution and Yield<br />

Vydac ® MS 300Å Silica Specifications<br />

Pore Size:<br />

300Å<br />

Pore Volume:<br />

0.5mL/g<br />

Surface Area: 90m 2 /g<br />

Vydac ® MS Phases<br />

Phase Particle Sizes Carbon Load Endcapped<br />

C4 5, 10, 15µm 3% Yes<br />

C8 5, 10, 15µm 5% Yes<br />

C18 5, 10, 15µm 8% Yes<br />

The Vydac ® column provides better separation and recovery for a highly hydrophobic membrane protein (RRV p14) and its fatty<br />

acid modified (myristolyated) form, a component of a potentially new vaccine delivery system.<br />

prep | columns<br />

1<br />

2<br />

4<br />

4<br />

3<br />

2<br />

4<br />

1 3<br />

10 20 30 40 50 60 65 Min.<br />

1<br />

2<br />

Transmembrane Protein p14 on 300Å C4 Columns<br />

Vydac ® MS<br />

C4 Column<br />

Competitor 1<br />

C4 Column<br />

Competitor 2<br />

C4 Column<br />

1. 18.8 kD Protein<br />

2. Non-myristoylated p14<br />

3. Myristoylated p14<br />

4. Triton ® X (Surfactant)<br />

Column Peak Area<br />

Peak 2 Peak 3<br />

MS C4 182 41<br />

Competitor 1 171 33<br />

Competitor 2 124 Not<br />

Detected<br />

Columns: Vydac ® MS C4 column 214MS54, Competitor 1 C4,<br />

Competitor 2 C4 (all 300Å, 4.6 x 250mm packed with<br />

5µm except 4µm for Competitor 1)<br />

Flow Rate:<br />

Eluent:<br />

1.0mL/min<br />

A: 0.1% v/v TFA in Water<br />

B: 0.085% v/v TFA in Acetonitrile<br />

Gradient:<br />

Vydac ® , Comp. 1: Time: 0 20 25 45<br />

%B: 20 60 80 80<br />

Comp. 2: Time: 0 20 25 45 50 80<br />

%B: 20 60 80 80 90 90<br />

Detector:<br />

UV at 215nm<br />

Column Temp: Ambient, 25°C<br />

Injection Vol: 50µL<br />

Reptilian reovirus RRV p14 sample courtesy of Drs. Roberto J. de Antueno and Roy Duncan, Dalhousie University, Halifax, Nova Scotia.<br />

Recovery of Proteins: MS vs. Leading Columns<br />

MS C18 recovery:<br />

• Up to 41% higher at low sample load<br />

• Up to 29% higher at high sample load<br />

% Higher Recovery<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

MS vs. Leading C18<br />

Loading<br />

Amount<br />

20µg<br />

50µg<br />

100µg<br />

MS C4 recovery:<br />

• Up to 57% higher at low sample load<br />

• Up to 12% higher at high sample load<br />

% Higher Recovery<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

MS vs. Leading C4<br />

Loading<br />

Amount<br />

20µg<br />

50µg<br />

100µg<br />

0<br />

Insulin<br />

5.7kD<br />

Ribonuclease<br />

13.7kD<br />

Myoglobin<br />

16.9kD<br />

0<br />

Cytochrome C<br />

11.6kD<br />

Column: C18 Columns (300Å, 5µm, 4.6 x 150mm): Vydac ® 238MS vs. leading protein/peptide C18<br />

C4 Columns (300Å, 5µm, 4.6 x 150mm): Vydac ® 214MS vs. leading protein/peptide C4<br />

Flow Rate: 1.0mL/min.<br />

Eluent:<br />

A: 0.1% v/v TFA in Water, B: 0.085% v/v TFA in Acetonitrile<br />

Temperature: 25°C<br />

Detector: UV at 280nm<br />

Gradient: C18 Columns = Time: 0 15 20 C4 Columns = Time: 0 12 15 20<br />

%B: 20 80 80 %B: 20 60 80 80<br />

BSA<br />

66.4kD<br />

Conalbumin<br />

75.8kD<br />

156 www.discoverysciences.com


prep | flash | tlc<br />

Vydac ® MS 300Å Columns<br />

Vydac ® MS 300Å Columns<br />

Packing Format i.d. x Length Part No.<br />

C4, 5µm Analytical 4.6 x 250mm 214MS54<br />

Prep—Threaded 10 x 150mm 214MS51015<br />

Prep—Threaded 10 x 250mm 214MS510<br />

Prep—Threaded 22 x 50mm 214MS52205<br />

Prep—Threaded 22 x 100mm 214MS52205<br />

C4, 10µm Analytical 4.6 x 250mm 214MS104<br />

Prep—Threaded 10 x 150mm 214MS101015<br />

Prep—Threaded 10 x 250mm 214MS1010<br />

Prep—Threaded 22 x 150mm 214MS102215<br />

Prep—Threaded 22 x 250mm 214MS1022<br />

Prep—Flanged 30 x 150mm 214MS103015<br />

Prep—Flanged 30 x 250mm 214MS1030<br />

C4, 15µm Analytical 4.6 x 250mm 214MS154<br />

Prep—Threaded 10 x 150mm 214MS151015<br />

Prep—Threaded 10 x 250mm 214MS1510<br />

Prep—Threaded 22 x 150mm 214MS152215<br />

Prep—Threaded 22 x 250mm 214MS1522<br />

Prep—Flanged 30 x 150mm 214MS153015<br />

Prep—Flanged 30 x 250mm 214MS1530<br />

Prep—Flanged 50 x 150mm 214MS155015<br />

Prep—Flanged 50 x 250mm 214MS1550<br />

Prep—Flanged 100 x 150mm 214MS1510015<br />

Prep—Flanged 100 x 250mm 214MS15100<br />

C8, 5µm Analytical 4.6 x 250mm 208MS54<br />

Prep—Threaded 10 x 150mm 208MS51015<br />

Prep—Threaded 10 x 250mm 208MS510<br />

Prep—Threaded 22 x 50mm 208MS52205<br />

Prep—Threaded 22 x 100mm 208MS52205<br />

C8, 10µm Analytical 4.6 x 250mm 208MS104<br />

Prep—Threaded 10 x 150mm 208MS101015<br />

Prep—Threaded 10 x 250mm 208MS1010<br />

Prep—Threaded 22 x 150mm 208MS102215<br />

Prep—Threaded 22 x 250mm 208MS1022<br />

Prep—Flanged 30 x 150mm 208MS103015<br />

Prep—Flanged 30 x 250mm 208MS1030<br />

C8, 15µm Analytical 4.6 x 250mm 208MS154<br />

Prep—Threaded 10 x 150mm 208MS151015<br />

Prep—Threaded 10 x 250mm 208MS1510<br />

Prep—Threaded 22 x 150mm 208MS152215<br />

Prep—Threaded 22 x 250mm 208MS1522<br />

Prep—Flanged 30 x 150mm 208MS153015<br />

Prep—Flanged 30 x 250mm 208MS1530<br />

Prep—Flanged 50 x 150mm 208MS155015<br />

Prep—Flanged 50 x 250mm 208MS1550<br />

Prep—Flanged 100 x 150mm 208MS1510015<br />

Prep—Flanged 100 x 250mm 208MS15100<br />

C18, 5µm Analytical 4.6 x 250mm 218MS54<br />

Prep—Threaded 10 x 150mm 218MS51015<br />

Prep—Threaded 10 x 250mm 218MS510<br />

Prep—Threaded 22 x 50mm 218MS52205<br />

Prep—Threaded 22 x 100mm 218MS52205<br />

C18, 10µm Analytical 4.6 x 250mm 218MS104<br />

Prep—Threaded 10 x 150mm 218MS101015<br />

Prep—Threaded 10 x 250mm 218MS1010<br />

Prep—Threaded 22 x 150mm 218MS102215<br />

Prep—Threaded 22 x 250mm 218MS1022<br />

Prep—Flanged 30 x 150mm 218MS103015<br />

Prep—Flanged 30 x 250mm 218MS1030<br />

Vydac ® MS 300Å Columns (continued)<br />

Packing Format i.d. x Length Part No.<br />

C18, 15µm Analytical 4.6 x 250mm 218MS154<br />

Prep—Threaded 10 x 150mm 218MS151015<br />

Prep—Threaded 10 x 250mm 218MS1510<br />

Prep—Threaded 22 x 150mm 218MS152215<br />

Prep—Threaded 22 x 250mm 218MS1522<br />

Prep—Flanged 30 x 150mm 218MS153015<br />

Prep—Flanged 30 x 250mm 218MS1530<br />

Prep—Flanged 50 x 150mm 218MS155015<br />

Prep—Flanged 50 x 250mm 218MS155015<br />

Prep—Flanged 100 x 150mm 218MS1510015<br />

Prep—Flanged 100 x 250mm 218MS15100<br />

Guard Cartridges and Holder<br />

Format i.d. x Length Qty. Part No.<br />

Prep—Guard Holder 10 x 10mm ea 2101342<br />

Prep—Guard Holder 20 x 10mm ea 3110650<br />

Prep—Guard Holder 30 x 30mm ea 3117320<br />

C4, 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 214GCC510<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 214GCC520<br />

C4, 10µm–15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 214GCC1010<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 214GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 214GCC1530<br />

C8, 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 208GCC510<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 208GCC520<br />

C8, 10µm–15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 208GCC1010<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 208GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 208GCC1530<br />

C18, 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 218GCC510<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 218GCC520<br />

C18, 10µm–15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 218GCC1010<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 218GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 218GCC1530<br />

related products<br />

Analytical columns<br />

and bulk media also<br />

available, please refer to<br />

pages 85–87 and 177,<br />

respectively.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

7110<br />

prep | columns<br />

www.discoverysciences.com<br />

157


prep | flash | tlc<br />

Vydac ® TP Columns<br />

300Å RP Protein Purification Pioneer<br />

• Trusted for over 25 years, Vydac ® TP provides reliable,<br />

high resolution of proteins and large peptides<br />

• Available in a wide range of bonding chemistries for<br />

alternative selectivity<br />

Referenced in over 9000 patents, Vydac ® TP is the 300Å<br />

phase to which all others are compared. It is relied upon in<br />

numerous commercial scale protein purifications and, like<br />

other <strong>Grace</strong> ® prep columns, is completely scalable to ton<br />

quantities.<br />

Vydac ® TP 300Å Silica<br />

Pore Size:<br />

300Å<br />

Pore Volume:<br />

0.6mL/g<br />

Surface Area: 90m 2 /g<br />

Vydac ® TP Phases<br />

Phase Particle Sizes Carbon Load Endcapped<br />

C4 5, 10, 10–15, 15–20µm 3% Yes<br />

C8 5, 10, 10–15, 15–20µm 5% Yes<br />

C18 5, 10, 10–15, 15–20µm 8% Yes<br />

Diphenyl 5, 10, 10–15, 15–20µm 4% Yes<br />

prep | columns<br />

Column Selection for Polypeptides<br />

The reversed-phase column for a polypeptide separation<br />

should be selected based on the hydrophobicity of the<br />

polypeptide being chromatographed and molecular weight<br />

as a secondary consideration.<br />

Molecular Weight<br />

1000<br />

Increasing hydrophilicity<br />

10,000<br />

100,000<br />

C 18<br />

=<br />

<strong>Grace</strong>Alpha<br />

C 18<br />

= 218TP, 238TP, 218MS<br />

C 8<br />

= 208TP, 208MS<br />

C 4<br />

= 214TP, 214MS<br />

Increasing hydrophobicity<br />

Diphenyl = 219TP<br />

Diphenyl columns (219TP, 219MS) are recommended for the<br />

separation of:<br />

• Polypeptides with aromatic side chains<br />

• Large, hydrophobic proteins<br />

• Lipid peptides<br />

• Membrane-spanning peptides<br />

• Fusion proteins from inclusion bodies<br />

C4 columns (214TP, 214MS) are recommended for the<br />

separation of:<br />

• Polypeptides larger than 4000–5000 MW<br />

• Very hydrophobic polypeptides of any size<br />

C8 columns (208TP, 208MS) are recommended for the<br />

separation of:<br />

• Polypeptides up to 10,000–20,000 MW<br />

• Enzymatic digest fragments<br />

• Natural and synthetic peptides<br />

C18 columns (218TP, 218MS, 238TP)<br />

are recommended for the separation of:<br />

• Peptides less than 4000–5000 MW<br />

• Enzymatic digest fragments<br />

• Natural and synthetic peptides<br />

Purification of Synthetic Peptide<br />

128mg of a synthetic peptide, GnRH antagonist, was<br />

purified to 99.7% purity by combining the optimum<br />

fractions. 1.2g of synthesis mixture was loaded onto a 5 x<br />

30cm column packed with Vydac ® C18 (218TP), 15–20µm<br />

and eluted with a gradient of acetonitrile in water containing<br />

triethylammonium phosphate.<br />

Absorbance Units (280nm)<br />

GnRH<br />

antagonist<br />

more info<br />

For more protein and peptide chromatograms, see our<br />

applications section.<br />

related products<br />

Analytical columns and bulk media also available, please refer to<br />

pages 70–71 and 177, respectively.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

0<br />

60 Min.<br />

158 www.discoverysciences.com


prep | flash | tlc<br />

Vydac ® TP Columns<br />

Vydac ® TP Columns<br />

Packing Format i.d. x Length Part No.<br />

C4 (214TP),<br />

5µm<br />

C4 (214TP),<br />

10µm<br />

C4 (214TP),<br />

10 –15µm<br />

C4 (214TP),<br />

15 –20µm<br />

C8 (208TP),<br />

5µm<br />

C8 (208TP),<br />

10µm<br />

C8 (208TP),<br />

10 –15µm<br />

C8 (208TP),<br />

15 –20µm<br />

C18 (218TP),<br />

5µm<br />

Analytical 4.6 x 250mm 214TP54<br />

Prep—Threaded 10 x 50mm 214TP51005<br />

Prep—Threaded 10 x 100mm 214TP51010<br />

Prep—Threaded 10 x 150mm 214TP51015<br />

Prep—Threaded 10 x 250mm 214TP510<br />

Prep—Threaded 22 x 50mm 214TP52205<br />

Prep—Threaded 22 x 100mm 214TP52205<br />

Analytical 4.6 x 250mm 214TP104<br />

Prep—Threaded 10 x 150mm 214TP101015<br />

Prep—Threaded 10 x 250mm 214TP1010<br />

Prep—Threaded 22 x 150mm 214TP102215<br />

Prep—Threaded 22 x 250mm 214TP1022<br />

Prep—Flanged 25 x 250mm 214TP1025<br />

Prep—Flanged 30 x 250mm 214TP1030<br />

Prep—Flanged 50 x 250mm 214TP1050<br />

Analytical 4.6 x 250mm 214TP10154<br />

Prep—Threaded 10 x 150mm 214TP10151015<br />

Prep—Threaded 10 x 250mm 214TP101510<br />

Prep—Threaded 22 x 150mm 214TP10152215<br />

Prep—Threaded 22 x 250mm 214TP101522<br />

Prep—Flanged 25 x 250mm 214TP101525<br />

Prep—Flanged 30 x 250mm 214TP101530<br />

Prep—Flanged 50 x 250mm 214TP101550<br />

Prep—Flanged 100 x 250mm 214TP1015100<br />

Prep—Flanged 100 x 500mm 214TP101510050<br />

Analytical 4.6 x 250mm 214TP15204<br />

Prep—Threaded 10 x 150mm 214TP15201520<br />

Prep—Threaded 10 x 250mm 214TP152010<br />

Prep—Threaded 22 x 150mm 214TP15202215<br />

Prep—Threaded 22 x 250mm 214TP152022<br />

Prep—Flanged 25 x 250mm 214TP152025<br />

Prep—Flanged 30 x 250mm 214TP152030<br />

Prep—Flanged 50 x 250mm 214TP152050<br />

Prep—Flanged 100 x 250mm 214TP1520100<br />

Prep—Flanged 100 x 500mm 214TP152010050<br />

Analytical 4.6 x 250mm 208TP54<br />

Prep—Threaded 10 x 250mm 208TP510<br />

Prep—Threaded 22 x 100mm 208TP52205<br />

Analytical 4.6 x 250mm 208TP104<br />

Prep—Threaded 10 x 250mm 208TP1010<br />

Prep—Threaded 22 x 250mm 208TP1022<br />

Prep—Flanged 25 x 250mm 208TP1025<br />

Prep—Flanged 30 x 250mm 208TP1030<br />

Prep—Flanged 50 x 250mm 208TP1050<br />

Analytical 4.6 x 250mm 208TP10154<br />

Prep—Threaded 10 x 250mm 208TP101510<br />

Prep—Threaded 22 x 250mm 208TP101522<br />

Prep—Flanged 25 x 250mm 208TP101525<br />

Prep—Flanged 30 x 250mm 208TP101530<br />

Prep—Flanged 50 x 250mm 208TP101550<br />

Prep—Flanged 100 x 250mm 208TP1015100<br />

Analytical 4.6 x 250mm 208TP15204<br />

Prep—Threaded 10 x 250mm 208TP152010<br />

Prep—Threaded 22 x 250mm 208TP152022<br />

Prep—Flanged 25 x 250mm 208TP152025<br />

Prep—Flanged 30 x 250mm 208TP152030<br />

Prep—Flanged 50 x 250mm 208TP152050<br />

Prep—Flanged 100 x 250mm 208TP1520100<br />

Analytical 4.6 x 250mm 218TP54<br />

Prep—Threaded 10 x 50mm 218TP51005<br />

Prep—Threaded 10 x 100mm 218TP51010<br />

Prep—Threaded 10 x 150mm 218TP51015<br />

Prep—Threaded 10 x 250mm 218TP510<br />

Prep—Threaded 22 x 50mm 218TP52205<br />

Prep—Threaded 22 x 100mm 218TP52205<br />

Vydac ® TP Columns (continued)<br />

Packing Format i.d. x Length Part No.<br />

C18 (218TP),<br />

10µm<br />

C18 (218TP),<br />

10 –15µm<br />

C18 (218TP),<br />

15 –20µm<br />

C18 (238TP),<br />

5µm<br />

C18 (238TP),<br />

10µm<br />

C18 (238TP),<br />

10 –15µm<br />

C18 (238TP),<br />

15 –20µm<br />

Diphenyl<br />

(219TP), 5µm<br />

Diphenyl<br />

(219TP), 10µm<br />

Analytical 4.6 x 250mm 218TP104<br />

Prep—Threaded 10 x 150mm 218TP101015<br />

Prep—Threaded 10 x 250mm 218TP1010<br />

Prep—Threaded 22 x 150mm 218TP102215<br />

Prep—Threaded 22 x 250mm 218TP1022<br />

Prep—Flanged 25 x 250mm 218TP1025<br />

Prep—Flanged 30 x 250mm 218TP1030<br />

Prep—Flanged 50 x 250mm 218TP1050<br />

Analytical 4.6 x 250mm 218TP10154<br />

Prep—Threaded 10 x 150mm 218TP10151015<br />

Prep—Threaded 10 x 250mm 218TP101510<br />

Prep—Threaded 22 x 150mm 218TP10152215<br />

Prep—Threaded 22 x 250mm 218TP101522<br />

Prep—Flanged 25 x 250mm 218TP101525<br />

Prep—Flanged 30 x 250mm 218TP101530<br />

Prep—Flanged 50 x 250mm 218TP101550<br />

Prep—Flanged 100 x 250mm 218TP1015100<br />

Prep—Flanged 100 x 500mm 218TP101510050<br />

Analytical 4.6 x 250mm 218TP15204<br />

Prep—Threaded 10 x 150mm 218TP15201520<br />

Prep—Threaded 10 x 250mm 218TP152010<br />

Prep—Threaded 22 x 150mm 218TP15202215<br />

Prep—Threaded 22 x 250mm 218TP152022<br />

Prep—Flanged 25 x 250mm 218TP152025<br />

Prep—Flanged 30 x 250mm 218TP152030<br />

Prep—Flanged 50 x 250mm 218TP152050<br />

Prep—Flanged 100 x 250mm 218TP1520100<br />

Prep—Flanged 100 x 500mm 218TP152010050<br />

Analytical 4.6 x 250mm 238TP54<br />

Prep—Threaded 10 x 250mm 238TP510<br />

Analytical 4.6 x 250mm 238TP104<br />

Prep—Threaded 10 x 250mm 238TP1010<br />

Prep—Threaded 22 x 250mm 238TP1022<br />

Prep—Flanged 25 x 250mm 238TP1025<br />

Prep—Flanged 30 x 250mm 238TP1030<br />

Prep—Flanged 50 x 250mm 238TP1050<br />

Analytical 4.6 x 250mm 238TP10154<br />

Prep—Threaded 10 x 250mm 238TP101510<br />

Prep—Threaded 22 x 250mm 238TP101522<br />

Prep—Flanged 25 x 250mm 238TP101525<br />

Prep—Flanged 30 x 250mm 238TP101530<br />

Prep—Flanged 50 x 250mm 238TP101550<br />

Prep—Flanged 100 x 250mm 238TP1015100<br />

Analytical 4.6 x 250mm 238TP15204<br />

Prep—Threaded 10 x 250mm 238TP152010<br />

Prep—Threaded 22 x 250mm 238TP152022<br />

Prep—Flanged 25 x 250mm 238TP152025<br />

Prep—Flanged 30 x 250mm 238TP152030<br />

Prep—Flanged 50 x 250mm 238TP152050<br />

Prep—Flanged 100 x 250mm 238TP1520100<br />

Analytical 4.6 x 250mm 219TP54<br />

Prep—Threaded 10 x 250mm 219TP510<br />

Analytical 4.6 x 250mm 219TP104<br />

Prep—Threaded 10 x 250mm 219TP1010<br />

Prep—Threaded 22 x 250mm 219TP1022<br />

Prep—Guard Col. 25 x 30mm 219TP102503<br />

Prep—Flanged 25 x 250mm 219TP1025<br />

Prep—Flanged 30 x 250mm 219TP1030<br />

Prep—Flanged 50 x 250mm 219TP1050<br />

prep | columns<br />

www.discoverysciences.com<br />

159


prep | flash | tlc<br />

prep | columns<br />

Vydac ® TP Columns<br />

Vydac ® TP Columns<br />

Packing Format i.d. x Length Part No.<br />

Diphenyl<br />

(219TP),<br />

10 –15µm<br />

Diphenyl<br />

(219TP),<br />

15 –20µm<br />

Analytical 4.6 x 250mm 219TP10154<br />

Prep—Threaded 10 x 250mm 219TP101510<br />

Prep—Threaded 22 x 250mm 219TP101522<br />

Prep—Guard Col. 25 x 30mm 219TP10152503<br />

Prep—Flanged 25 x 250mm 219TP101525<br />

Prep—Flanged 30 x 250mm 219TP101530<br />

Prep—Flanged 50 x 250mm 219TP101550<br />

Prep—Flanged 100 x 250mm 219TP1015100<br />

Analytical 4.6 x 250mm 219TP15204<br />

Prep—Threaded 10 x 250mm 219TP152010<br />

Prep—Threaded 22 x 250mm 219TP152022<br />

Prep—Guard Col. 25 x 30mm 219TP15202503<br />

Prep—Flanged 25 x 250mm 219TP152025<br />

Prep—Flanged 30 x 250mm 219TP152030<br />

Prep—Flanged 50 x 250mm 219TP152050<br />

Prep—Flanged 100 x 250mm 219TP1520100<br />

Guard Cartridges and Holder<br />

Format i.d. x Length Qty. Part No.<br />

Prep—Guard Holder 10 x 10mm ea 2101342<br />

Prep—Guard Holder 20 x 10mm ea 3110650<br />

Prep—Guard Holder 30 x 30mm ea 3117320<br />

C4 (214TP), 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 214GCC510<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 214GCC520<br />

C4 (214TP), 10µm<br />

Prep—Guard Cartridge 10 x 10mm ea 214GCC1010<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 214GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 214GCC1530<br />

C4 (214TP), 10 –15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 214GCC101510<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 214GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 214GCC1530<br />

C4 (214TP), 15 –20µm<br />

Prep—Guard Cartridge 10 x 10mm ea 214GCC152010<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 214GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 214GCC1530<br />

C8 (208TP), 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 208GCC510<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 208GCC520<br />

Guard Cartridges and Holder (continued)<br />

Format i.d. x Length Qty. Part No.<br />

C8 (208TP), 10µm<br />

Prep—Guard Cartridge 10 x 10mm ea 208GCC1010<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 208GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 208GCC1530<br />

C8 (208TP), 10 –15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 208GCC101510<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 208GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 208GCC1530<br />

C8 (208TP), 15 –20µm<br />

Prep—Guard Cartridge 10 x 10mm ea 208GCC152010<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 208GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 208GCC1530<br />

C18 (218TP), 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 218GCC510<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 218GCC520<br />

C18 (218TP), 10µm<br />

Prep—Guard Cartridge 10 x 10mm ea 218GCC1010<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 218GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 218GCC1530<br />

C18 (218TP), 10 –15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 218GCC101510<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 218GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 218GCC1530<br />

C18 (218TP), 15 –20µm<br />

Prep—Guard Cartridge 10 x 10mm ea 218GCC152010<br />

Prep—Guard Cartridge 20 x 10mm 2/pk 218GCC1520<br />

Prep—Guard Cartridge 30 x 30mm ea 218GCC1530<br />

C18 (238TP), 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 238GCC510<br />

C18 (238TP), 10µm<br />

Prep—Guard Cartridge 10 x 10mm ea 238GCC1010<br />

C18 (238TP), 10 –15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 238GCC101510<br />

C18 (238TP), 15 –20µm<br />

Prep—Guard Cartridge 10 x 10mm ea 238GCC152010<br />

Diphenyl (219TP), 5µm<br />

Prep—Guard Cartridge 10 x 10mm ea 219GCC510<br />

Diphenyl (219TP), 10µm<br />

Prep—Guard Cartridge 10 x 10mm ea 219GCC1010<br />

Diphenyl (219TP), 10 –15µm<br />

Prep—Guard Cartridge 10 x 10mm ea 219GCC101510<br />

Diphenyl (219TP), 15 –20µm<br />

Prep—Guard Cartridge 10 x 10mm ea 219GCC152010<br />

160<br />

Purification of a Lipid Peptide<br />

A synthetic peptide containing 25 amino acid residues and two<br />

attached fatty acids was difficult to purify because of its limited<br />

solubility and tendency to aggregate. The lower retentivity of the<br />

Vydac ® 219TP54 diphenyl reversed-phase column was useful for<br />

purification of this peptide after it was found to be retained so strongly<br />

that it could not be eluted from a C4 reversed phase.<br />

Column:<br />

Flow:<br />

Detector:<br />

Vydac ® 219TP54 (diphenyl, 5µm, 4.6mm i.d. x 250mm)<br />

0.75mL/min<br />

UV at 280nm<br />

Trial Chromatogram<br />

Sample: 250µL of 8:1 diluted peptide solution = 71µg<br />

Eluent: A: 5% n-propanol/0.5% HOAc/94.5% water<br />

B: 85% n-propanol/0.5% HOAc/14.5% water<br />

Gradient: 0 to 100% B in 30min<br />

Preparative Chromatogram<br />

Sample: 1.5mL of 3:1 diluted peptide solution = 1.14mg (applied<br />

as three 500µL injections at 1.5min intervals)<br />

Eluent: A: 29% n-propanol/0.5% HOAc/70.5% water<br />

B: 61% n-propanol/0.5% HOAc/38.5% water<br />

Gradient: Hold 100% A for 6min, then 0 to 100% B in 30min<br />

In each chromatogram the fine trace is a post-run blank.<br />

Sample courtesy of Dr. Don Diamond (City of Hope National Medical Center, Duarte,<br />

Calif.). For a complete description of this method development, request Vydac ®<br />

Application Note #9802.<br />

0.016<br />

0.10<br />

AU<br />

0<br />

AU<br />

0<br />

0<br />

71µg<br />

Trial<br />

Chromatogram<br />

0 20 40<br />

1.14mg<br />

Preparative<br />

Chromatogram<br />

60 Min.<br />

20 40 60 Min.


prep | flash | tlc<br />

Alltech ® Prep Columns<br />

• Packed with identical media to analytical columns<br />

• Additional dimensions may be custom ordered<br />

Econosphere Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 10µm Prep—Threaded 10 x 100mm 28157<br />

Prep—Threaded 10 x 250mm 28085<br />

Prep—Threaded 22 x 250mm 28001<br />

C8, 10µm Prep—Threaded 10 x 100mm 28159<br />

Prep—Threaded 10 x 250mm 28087<br />

Prep—Threaded 22 x 250mm 28003<br />

Silica, 10µm Prep—Threaded 10 x 100mm 28167<br />

Prep—Threaded 10 x 250mm 28095<br />

Prep—Threaded 22 x 250mm 28057<br />

Macrosphere Columns<br />

Packing Format i.d. x Length Part No.<br />

GPC 60Å Prep—Threaded 7.5 x 300mm 88175<br />

GPC 100Å Prep—Threaded 7.5 x 300mm 88177<br />

GPC 150Å Prep—Threaded 7.5 x 300mm 88179<br />

GPC 300Å Prep—Threaded 7.5 x 300mm 88181<br />

Alltima Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 5µm Prep—Threaded 7 x 150mm 81123<br />

Prep—Threaded 7 x 250mm 81129<br />

Prep—Threaded 10 x 150mm 81102<br />

Prep—Threaded 10 x 250mm 88063<br />

Prep—Threaded 22 x 150mm 81106<br />

Prep—Threaded 22 x 250mm 81105<br />

C18, 10µm Prep—Threaded 10 x 150mm 81107<br />

Prep—Threaded 10 x 250mm 88334<br />

Prep—Threaded 22 x 150mm 81108<br />

Prep—Threaded 22 x 250mm 88335<br />

C8, 5µm Prep—Threaded 7 x 150mm 81132<br />

Prep—Threaded 7 x 250mm 81133<br />

Prep—Threaded 10 x 150mm 81109<br />

Prep—Threaded 10 x 250mm 88081<br />

Prep—Threaded 22 x 150mm 81112<br />

Prep—Threaded 22 x 250mm 81110<br />

C8, 10µm Prep—Threaded 10 x 150mm 81114<br />

Prep—Threaded 10 x 250mm 88336<br />

Prep—Threaded 22 x 150mm 81115<br />

Prep—Threaded 22 x 250mm 81110<br />

Silica, 5µm Prep—Threaded 7 x 150mm 81135<br />

Prep—Threaded 7 x 250mm 81136<br />

Prep—Threaded 10 x 150mm 81117<br />

Prep—Threaded 10 x 250mm 81116<br />

Prep—Threaded 22 x 150mm 81119<br />

Prep—Threaded 22 x 250mm 81118<br />

Silica, 10µm Prep—Threaded 10 x 150mm 81121<br />

Prep—Threaded 10 x 250mm 88338<br />

Prep—Threaded 22 x 150mm 81125<br />

Prep—Threaded 22 x 250mm 88339<br />

Platinum Columns<br />

Packing Format i.d. x Length Part No.<br />

EPS C18, 5µm Prep—Threaded 10 x 150mm 82083<br />

Prep—Threaded 22 x 150mm 82093<br />

Prep—Threaded 22 x 250mm 82095<br />

Prosphere HP<br />

Packing Format i.d. x Length Part No.<br />

C18-AQ, 5µm Prep—Threaded 10 x 100mm 35572<br />

Prep—Threaded 22 x 100mm 35573<br />

related products<br />

Please refer to pages 44–49, 54–57, and 96–97 for more<br />

information on media characteristics and analytical column<br />

offerings.<br />

Apollo Columns<br />

Packing Format i.d. x Length Part No.<br />

C18, 5µm Prep—Threaded 7 x 150mm 36530<br />

Prep—Threaded 7 x 250mm 36541<br />

Prep—Threaded 10 x 150mm 36531<br />

Prep—Threaded 10 x 250mm 36543<br />

Prep—Threaded 22 x 150mm 36526<br />

Prep—Threaded 22 x 250mm 36537<br />

C8, 5µm Prep—Threaded 7 x 150mm 36546<br />

Prep—Threaded 7 x 250mm 36547<br />

Prep—Threaded 10 x 150mm 36548<br />

Prep—Threaded 10 x 250mm 36549<br />

Prep—Threaded 22 x 150mm 36550<br />

Prep—Threaded 22 x 250mm 36551<br />

Phenyl, 5µm Prep—Threaded 7 x 150mm 36525<br />

Prep—Threaded 7 x 250mm 36539<br />

Prep—Threaded 10 x 150mm 36527<br />

Prep—Threaded 10 x 250mm 36532<br />

Prep—Threaded 22 x 150mm 36535<br />

Prep—Threaded 22 x 250mm 36528<br />

Silica, 5µm Prep—Threaded 7 x 150mm 36542<br />

Prep—Threaded 7 x 250mm 36529<br />

Prep—Threaded 10 x 150mm 36533<br />

Prep—Threaded 10 x 250mm 36540<br />

Prep—Threaded 22 x 150mm 36534<br />

Prep—Threaded 22 x 250mm 36524<br />

Prevail Columns<br />

Packing Format i.d. x Length Part No.<br />

Carbohydrate ES, 5µm Prep—Threaded 7 x 100mm 35103<br />

Prep—Threaded 10 x 250mm 35115<br />

Prep—Threaded 20 x 300mm 35215<br />

C18, 5µm Prep—Threaded 10 x 150mm 99293<br />

Prep—Threaded 10 x 250mm 99294<br />

Prep—Threaded 22 x 150mm 99296<br />

Prep—Threaded 22 x 250mm 99297<br />

6286 6285<br />

Connect with Direct-Connect Connect In-Line with Fittings<br />

Coupler.<br />

and Tubing.<br />

Prep-Guard Accessories<br />

Description<br />

Part No.<br />

Direct-Connect Column Coupler 28195<br />

In-Line Connector 9549<br />

Alltech ® Prep Guards<br />

Packing Format i.d. x Length Part No.<br />

Econosphere Guards<br />

C18, 10µm Prep—Guard 7 x 33mm 970209<br />

C8, 10µm Prep—Guard 7 x 33mm 970223<br />

Silica, 10µm Prep—Guard 7 x 33mm 970210<br />

Alltima Guards<br />

C18, 10µm Prep—Guard 7 x 33mm 970203<br />

C8, 10µm Prep—Guard 7 x 33mm 970227<br />

Silica, 10µm Prep—Guard 7 x 33mm 970204<br />

Platinum Guard<br />

EPS C18, 5µm Prep—Guard 7 x 33mm 970216<br />

Prosphere HP Guard<br />

C18-AQ, 5µm Prep—Guard 7 x 33mm 35584<br />

Apollo Guards<br />

C18, 5µm Prep—Guard 7 x 33mm 970205<br />

C8, 5µm Prep—Guard 7 x 33mm 96463<br />

Phenyl, 5µm Prep—Guard 7 x 33mm 96430<br />

Silica, 5µm Prep—Guard 7 x 33mm 970206<br />

Prevail Guards<br />

Carbohydrate ES, 5µm Prep—Guard 7 x 33mm 35105<br />

C18, 5µm Prep—Guard 7 x 33mm 970211<br />

www.discoverysciences.com<br />

prep | columns<br />

161


prep | flash | tlc<br />

Spring Column Hardware<br />

For Use with Multipacker ® Packing Instruments<br />

• High-efficiency axial compression packing mechanism<br />

• Extend media lifetime<br />

• Mobile Dynamic Axial Compression (DAC) column<br />

• Easily packed by end-user with a Multipacker ® instrument<br />

The Spring Column hardware described in this section<br />

is designed to be used in conjunction with Multipacker ®<br />

instruments. Please see page 172 for information on the<br />

Multipacker ® product line.<br />

prep | columns<br />

Spring Column units are also available prepacked<br />

and ready-to-use. However, prepacked Spring Column<br />

units are not user-serviceable and must be returned to <strong>Grace</strong><br />

for repacking, unless the customer owns a Multipacker ®<br />

packing system.<br />

How to Order Spring Column Hardware for Use<br />

with Multipacker ® Instruments<br />

Spring Columns can be ordered as a complete kit, as seen<br />

on page 163, or customized selecting the options that best<br />

suit your needs. Components for customization can be found<br />

on page 164. Spring Columns are offered in two lengths,<br />

40cm and 70cm. A 40cm column body can accommodate up<br />

to a 15cm length packed bed and the 70cm column body can<br />

accommodate up to a 30cm length packed bed.<br />

Each complete Spring Column assembly consists of<br />

five components. For customized columns, one of each<br />

component below needs to be ordered:<br />

1. The Base Spring Column Parts Kit includes:<br />

a. Column Body<br />

b. All Seals and O-rings<br />

c. Locking Mechanism<br />

d. Guide Tube<br />

e. Endplate<br />

f. Assembly Hardware<br />

g. Packing Spacers (for 70cm length columns)—not<br />

pictured<br />

2. A Ready-to-Use Piston Assembly consisting of the piston<br />

body, piston frit, PTFE sleeve and O-ring. The piston<br />

assembly can be ordered with a 1µm, 2µm, or 5µm frit<br />

porosity.<br />

3. A Spring Kit. Choose the appropriate pressure range<br />

for your needs. Spring force must exceed the operating<br />

pressure of the column in order to maintain axial<br />

compression force.<br />

4. An Outlet Frit. Choose 1µm, 2µm, or 5µm frit porosity.<br />

For 101mm i.d. columns, the outlet frit is identical to the<br />

piston assembly (#2).<br />

5. Tubing and Connectors. Choose tubing with an outer<br />

diameter and bore that suits your needs.<br />

c<br />

2<br />

related products<br />

Refer to page 172 for more<br />

information on the Multipacker ®<br />

packing stations used to pack<br />

Spring Column hardware.<br />

7410<br />

Base Spring Colum Parts Kit<br />

4<br />

b<br />

3<br />

d<br />

a<br />

e<br />

f<br />

The guides on the following pages will help you select the<br />

combination of options appropriate to your needs. For further<br />

assistance, call <strong>Grace</strong> Technical Support.<br />

7403<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

162 www.discoverysciences.com


prep | flash | tlc<br />

Spring Column Hardware<br />

Complete Spring Column Hardware Kits<br />

Complete hardware kits are available under single catalog numbers for standard 25mm i.d, 50mm i.d, and 101mm i.d. Spring<br />

Column units, as shown below.<br />

Complete kits are provided with 2µm frits and 1000 to 2000psig springs. Different combinations are possible by building a custom<br />

Spring Column on page 164.<br />

Individual components and replacement parts are listed on the following two pages.<br />

Complete Spring Column Hardware Kits<br />

Column Dimensions Part No. Description<br />

25mm i.d.<br />

25mm i.d. x 40cm,<br />

Non-Water-Jacketed<br />

25mm i.d. x 70cm,<br />

Non-Water-Jacketed<br />

50mm i.d.<br />

50mm i.d. x 40cm,<br />

Non-Water-Jacketed**<br />

50mm i.d. x 70cm,<br />

Non-Water-Jacketed**<br />

101mm i.d.<br />

101mm i.d. x 40cm,<br />

Water-Jacketed<br />

101mm i.d. x 70cm,<br />

Water-Jacketed<br />

SA2002-025040<br />

AS2002-025A09<br />

AF0000-C02502<br />

AS2002-025A03<br />

AS2002-025A07<br />

SA2002-025070<br />

AS2002-025A09<br />

AF0000-C02502<br />

AS2002-025A03<br />

AS2002-025A07<br />

SA2002-050040<br />

AS2002-050A01<br />

AF0000-B05002<br />

AS2002-050A03<br />

AS2002-050A07<br />

AS2002-050A09<br />

SA2002-050070<br />

AS2002-050A01<br />

AF0000-B05002<br />

AS2002-050A03<br />

AS2002-050A07<br />

AS2002-050A09<br />

SA4004-101040<br />

2 x AS4004-101A06<br />

AS4004-101A03<br />

AS2002-050A08<br />

SA4004-101070<br />

2 x AS4004-101A06<br />

AS4004-101A03<br />

AS2002-050A08s<br />

Includes:<br />

Base Column Parts Kit*, 40cm long column, for bed lengths up to 15cm<br />

Piston Assembly with 2µm frit<br />

Outlet Frit, 2µm<br />

Spring Kit for packing pressures from 1000 to 2000psig<br />

1/16” o.d., 0.040” i.d. Connecting Tube and Fittings<br />

Base Column Parts Kit*, 70cm long column, for bed lengths up to 30cm<br />

Piston Assembly with 2µm frit<br />

Outlet Frit, 2µm<br />

Spring Kit for packing pressures from 1000 to 2000psig<br />

1/16” o.d., 0.040” i.d. Connecting Tube and Fittings<br />

Base Column Parts Kit*, 40cm long column, for bed lengths up to 15cm<br />

Piston Assembly with 2µm frit<br />

Outlet Frit, 2µm<br />

Spring Kit for packing pressures from 1000 to 2000psig<br />

1/16” o.d., 0.040” i.d. Connecting Tube and Fittings<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings<br />

Base Column Parts Kit*, 70cm long column, for bed lengths up to 30cm<br />

Piston Assembly with 2µm frit<br />

Outlet Frit, 2µm<br />

Spring Kit for packing pressures from 1000 to 2000psig<br />

1/16” o.d., 0.040” i.d. Connecting Tube and Fittings<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings<br />

Base Column Parts Kit*, 40cm long column, for bed lengths up to 15cm<br />

Piston Assembly with 2µm frit<br />

Spring Kit for packing pressures up to 2000psig<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings<br />

Base Column Parts Kit*, 70cm long column, for bed lengths up to 30cm<br />

Piston Assembly with 2µm frit<br />

Spring Kit for packing pressures up to 2000psig<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings<br />

Part No.<br />

SC2002-025040<br />

SC2002-025070<br />

SC2002-050040<br />

SC2002-050070<br />

SC4004-101040<br />

SC4004-101070<br />

NOTE:<br />

Spring Column units are designed to be easily serviceable. A full array of components and replacement parts are available. Please consult the listings on the following two pages as<br />

well as the column manuals for details.<br />

*See page 162 for listing of components included in Base Column Parts Kit.<br />

**Two sizes of connecting tubing provided.<br />

prep | columns<br />

7412<br />

www.discoverysciences.com<br />

163


prep | flash | tlc<br />

Spring Column Hardware<br />

Spring Column Components<br />

Experienced Spring Column users can build customized Spring Column units by individually selecting the components that<br />

best meet their needs. A total of five components is needed to assemble a complete Spring Column.<br />

prep | columns<br />

Spring Column Units<br />

Column Dimensions Description Part No.<br />

25mm i.d.<br />

1. Base Parts Kit Non-Water-Jacketed Kit, 40cm long, for bed lengths up to 15cm SA2002-025040<br />

Water-Jacketed Kit, 40cm long, for bed lengths up to 15cm<br />

SA2002-W25040<br />

Non-Water-Jacketed Kit, 70cm long, for bed lengths up to 30cm<br />

SA2002-025070<br />

Water-Jacketed Kit, 70cm long, for bed lengths up to 30cm<br />

SA2002-W25070<br />

2. Piston Assembly Piston Assembly with 1µm frit AS2002-025A01<br />

Piston Assembly with 2µm frit<br />

AS2002-025A09<br />

Piston Assembly with 5µm frit<br />

AS2002-025A02<br />

3. Spring Kit Spring Kit for packing pressures from 1000 to 2000psig AS2002-025A03<br />

Spring Kit for packing pressures from 500 to 900psig<br />

AS2002-025A04<br />

Spring Kit for packing pressures up to 400psig<br />

AS2002-025A05<br />

4. Outlet Frit Outlet Frit, 1µm AF0000-C02501<br />

Outlet Frit, 2µm<br />

AF0000-C02502<br />

Outlet Frit, 5µm<br />

AF0000-C02503<br />

5. Tubing and Connectors 1/16” o.d., 0.020” i.d. Connecting Tube and Fittings AS2002-025A06<br />

1/16” o.d., 0.040” i.d. Connecting Tube and Fittings AS2002-025A07<br />

50mm i.d.<br />

1. Base Parts Kit Non-Water-Jacketed Kit, 40cm long, for bed lengths up to 15cm SA2002-050040<br />

Water-Jacketed Kit, 40cm long, for bed lengths up to 15cm<br />

SA2002-W50040<br />

Non-Water-Jacketed Kit, 70cm long, for bed lengths up to 30cm<br />

SA2002-050070<br />

Water-Jacketed Kit, 70cm long, for bed lengths up to 30cm<br />

SA2002-W50070<br />

2. Piston Assembly Piston Assembly with 1µm frit AS2002-050A01<br />

Piston Assembly with 2µm frit<br />

AS2002-050A11<br />

Piston Assembly with 5µm frit<br />

AS2002-050A02<br />

3. Spring Kit Spring Kit for packing pressures from 1000 to 2000psig AS2002-050A03<br />

Spring Kit for packing pressures from 500 to 900psig<br />

AS2002-050A05<br />

Spring Kit for packing pressures up to 400psig<br />

AS2002-050A06<br />

4. Outlet Frit Outlet Frit, 1µm AF0000-B05001<br />

Outlet Frit, 2µm<br />

AF0000-B05002<br />

Outlet Frit, 5µm<br />

AF0000-B05003<br />

5. Tubing and Connectors 1/16” o.d., 0.040” i.d. Connecting Tube and Fittings AS2002-050A07<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings AS2002-050A08<br />

1/8” o.d., 0.085” i.d. Connecting Tube and Fittings AS2002-050A09<br />

101mm i.d.<br />

1. Base Parts Kit Non-Water-Jacketed Kit, 40cm long, for bed lengths up to 15cm SA4004-N10140<br />

Water-Jacketed Kit, 40cm long, for bed lengths up to 15cm<br />

SA4004-101040<br />

Non-Water-Jacketed Kit, 70cm long, for bed lengths up to 30cm<br />

SA4004-N10170<br />

Water-Jacketed Kit, 70cm long, for bed lengths up to 30cm<br />

SA4004-101070<br />

2. Piston Assembly<br />

Piston Assembly with 1µm frit<br />

AS4004-101A01<br />

(Need Qty. 2)<br />

Piston Assembly with 2µm frit<br />

AS4004-101A06<br />

Piston Assembly with 5µm frit<br />

AS4004-101A02<br />

3. Spring Kit Spring Kit for packing pressures from 1000 to 2000psig AS4004-101A03<br />

Spring Kit for packing pressures from 500 to 900psig<br />

AS4004-101A04<br />

Spring Kit for packing pressures up to 400psig<br />

AS4004-101A05<br />

4. Tubing and Connectors 1/8” o.d., 0.060” i.d. Connecting Tube and Fittings AS2002-050A08<br />

1/8” o.d., 0.085” i.d. Connecting Tube and Fittings AS2002-050A09<br />

more info<br />

For a listing of the individual parts included in the kits and<br />

assemblies above, please refer to page 162.<br />

tech tip<br />

Selecting the correct frit porosity ensures particles are retained in<br />

the column while contributing minimally to backpressure. See the<br />

recommendation below.<br />

Particle Size<br />

Recommended Frit Porosity<br />

10µm 5µm<br />

164 www.discoverysciences.com


prep | flash | tlc<br />

Spring Column Hardware<br />

Repack Kits for Spring Columns<br />

Popular frit porosities, 2µm and 5µm, are available bundled with the appropriate replacement consumables needed when<br />

repacking. 1µm frits are available below in the replacement parts list.<br />

The 25 and 50mm i.d. repack kits contain consumable parts for three repacks. The 101mm i.d. repack kits contain parts for<br />

one repack.<br />

Repack Kits for Spring Column Modules<br />

Includes:<br />

Column Dimensions Qty. Part No. Description<br />

25mm i.d.<br />

With 2µm Frits 3<br />

3<br />

3<br />

3<br />

AF0000-C02502<br />

AH0000-R025A1<br />

AF0000-D02501<br />

AS2002-025A14<br />

Outlet Frit, 2µm<br />

Outlet O-ring Set<br />

Outlet Disperser Frit<br />

Piston Frit Replacement Kit*, 2µm<br />

With 5µm Frits 3<br />

3<br />

3<br />

3<br />

50mm i.d.<br />

With 2µm Frits 3<br />

3<br />

3<br />

3<br />

With 5µm Frits 3<br />

3<br />

3<br />

3<br />

101mm i.d.<br />

With 2µm Frits 2<br />

2<br />

2<br />

With 5µm Frits 2<br />

2<br />

2<br />

AF0000-C02503<br />

AH0000-R025A1<br />

AF0000-D02501<br />

AS2002-025A13<br />

AF0000-B05002<br />

AH0000-R050A1<br />

AF0000-D05001<br />

AS2002-050A16<br />

AF0000-B05003<br />

AH0000-R050A1<br />

AF0000-D05001<br />

AS2002-050A15<br />

AS4004-101A18<br />

AS4004-101011<br />

AS4004-101012<br />

AS4004-101A17<br />

AS4004-101011<br />

AS4004-101012<br />

*Components of the Piston Frit Replacement Kit are listed below.<br />

Outlet Frit, 5µm<br />

Outlet O-ring Set<br />

Outlet Disperser Frit<br />

Piston Frit Replacement Kit*, 5µm<br />

Outlet Frit, 2µm<br />

Outlet O-ring Set<br />

Outlet Disperser Frit<br />

Piston Frit Replacement Kit*, 2µm<br />

Outlet Frit, 5µm<br />

Outlet O-ring Set<br />

Outlet Disperser Frit<br />

Piston Frit Replacement Kit*, 5µm<br />

Piston Frit Replacement Kit*, 2µm<br />

Piston O-ring<br />

PTFE Sleeve<br />

Piston Frit Replacement Kit*, 5µm<br />

Piston O-ring<br />

PTFE Sleeve<br />

Part No.<br />

AS2002-025A16<br />

AS2002-025A17<br />

AS2002-050A18<br />

AS2002-050A19<br />

AS4004-101A20<br />

AS4004-101A21<br />

prep | columns<br />

Replacement Parts for Spring Columns<br />

In addition to the repack kits listed above, a full array of individual component replacement parts may be ordered from the list below.<br />

Spring Column Replacement Parts<br />

Description For 25mm i.d. For 50mm i.d. For 101mm i.d.<br />

Top Restraint — — AS4004-101008<br />

Bottom Restraint — — AS4004-101009<br />

Piston Top — — AS4004-101010<br />

Piston O-ring AS2002-025011 AS2002-050011 AS4004-101011<br />

Guide Tube AS2002-025013 AS2002-050013 AS4004-101013<br />

Column Body, 40 cm Long Non-Water-Jacketed FS2002-025040 FS2002-050040 AS4004-N10140<br />

Column Body, 70 cm Long Non-Water-Jacketed FS2002-025070 FS2002-050070 AS4004-N10170<br />

Column Body, 40 cm Long Water-Jacketed FS2002-W25040 FS2002-W50040 AS4004-101040<br />

Column Body, 70 cm Long Water-Jacketed FS2002-W25070 FS2002-W50070 AS4004-101070<br />

Outlet Disperser Frit AF0000-D02501 AF0000-D05001 —<br />

Outlet Frit, 1µm AF0000-C02501 AF0000-B05001 —<br />

Outlet Frit, 2µm AF0000-C02502 AF0000-B05002 —<br />

Outlet Frit, 5µm AF0000-C02503 AF0000-B05003 —<br />

Outlet O-ring Set AH0000-R025A1 AH0000-R050A1 —<br />

Replacement Bolts, Nuts, and Washers for Non-Water-Jacketed Column AS2002-025A08 AS2002-050A10 —<br />

Replacement Bolts, Nuts, and Washers for Water-Jacketed Column AS2002-025A11 AS2002-050A13 —<br />

Threaded Spacer for 40cm Long Column AS2002-025000 AS2002-050000 AS4004-101000<br />

Threaded Spacer for 70cm Long Column AS2002-025001 AS2002-050001 AS4004-101001<br />

Threaded Flange AS2002-025002 AS2002-050002 AS4004-101002<br />

Packing Spacer AS2002-025003 AS2002-050003 AS4004-101003<br />

Unpacking Spacer for 40cm Long Columns AS2002-025004 AS2002-050004 AS4004-101004<br />

Unpacking Spacer for 70cm Long Columns AS2002-025005 AS2002-050005 AS4004-101005<br />

Piston AS2002-025007 AS2002-050007 AS4004-101007<br />

Piston Frit Replacement Kit (Piston O-ring, 1µm Double Density Frit, PTFE Sleeve), 1µm AS2002-025A12 AS2002-050A14 AS4004-101A16<br />

Piston Frit Replacement Kit (Piston O-ring, 2µm Double Density Frit, PTFE Sleeve), 2µm AS2002-025A14 AS2002-050A16 AS4004-101A18<br />

Piston Frit Replacement Kit (Piston O-ring, 5µm Double Density Frit, PTFE Sleeve), 5µm AS2002-025A13 AS2002-050A15 AS4004-101A17<br />

PTFE Sleeve AS2002-025010 AS2002-050010 AS4004-101012<br />

www.discoverysciences.com<br />

165


prep | flash | tlc<br />

Axial SFC Column Hardware<br />

For Use with Multipacker ® Packing<br />

Instruments<br />

Rugged SFC Sealing System<br />

The sealing materials for axial SFC columns have been<br />

chosen for their compatibility with modified supercritical<br />

carbon dioxide typically employed in SFC systems. The seal<br />

system is rated for continuous operation at pressures of up<br />

to 5000psig (345 bar).<br />

Piston<br />

A pure PTFE O-ring primary seal and a Turcon ® spring-loaded<br />

lip secondary seal comprise the sealing mechanism for the<br />

piston.<br />

prep | columns<br />

• High efficiency packing mechanism<br />

• Rated to 5000psig for SFC<br />

• Easily packed by end-user with Multipacker ® instrument<br />

<strong>Grace</strong> Axial SFC Columns are design-related to Spring<br />

Column axial compression columns. They are packed with<br />

the same, easy-to-use Multipacker ® packing systems but<br />

are designed with the requirements of supercritical fluid<br />

chromatography in mind. Custom seals, suitable for use<br />

with supercritical CO2 at pressures up to 5000psig, are<br />

manufactured specially for <strong>Grace</strong>. The axial compression<br />

packing mode is still employed. However, the internal spring<br />

axial compression has been omitted because of the high<br />

pressures typical in SFC systems and the low visosity of the<br />

mobile phase, which makes void formation less likely.<br />

7413<br />

Column Outlet<br />

7405 7406<br />

The column outlet seals system is composed of a Turcon ®<br />

spring-loaded lip seal and a bronze backup ring.<br />

Axial SFC Column Hardware Specifications<br />

Wet Surfaces: Electropolished Type 316 Stainless Steel, PTFE<br />

Column Body: Electropolished Type 316 Stainless Steel<br />

Piston:<br />

Electropolished Type 316 Stainless Steel<br />

Threaded Spacer: Type 6061 Aluminum<br />

Endplate:<br />

Electropolished Type 316 Stainless Steel<br />

Bolting Hardware: Grade 8, qualified for pressure vessels<br />

Frits:<br />

Passivated Sintered Type 316 Stainless Steel<br />

O-ring Seals:<br />

PTFE<br />

Lip Seals: Turcon ®<br />

Backup Ring: Bronze<br />

Pressure Rating: 5000psig (345 bar)<br />

Max. Temperature: 135°C (275°F)<br />

related products<br />

Refer to page 172 for more<br />

information on the Multipacker ®<br />

packing stations used to pack<br />

Axial SFC column hardware.<br />

7407 7408<br />

7403<br />

166 www.discoverysciences.com


prep | flash | tlc<br />

Axial SFC Column Hardware<br />

Complete Axial SFC Column Hardware Kits<br />

Complete hardware kits are available under single catalog numbers for standard 25mm i.d. and 50mm i.d. water-jacketed axial<br />

SFC columns, as shown below. Individual components and replacement parts are listed on the following two pages.<br />

Axial SFC Columns<br />

Column Dimensions Part No. Description<br />

25mm i.d.<br />

25mm i.d. x 40cm,<br />

Water-Jacketed<br />

25mm i.d. x 70cm,<br />

Water-Jacketed<br />

50mm i.d.<br />

50mm i.d. x 40cm,<br />

Water-Jacketed<br />

50mm i.d. x 70cm,<br />

Water-Jacketed<br />

AY2002-W25040<br />

AY2002-025A01<br />

AF0000-C02501<br />

AS2002-025A07<br />

AY2002-W25070<br />

AY2002-025A01<br />

AF0000-C02501<br />

AS2002-025A07<br />

AY2002-W50040<br />

AY2002-050A01<br />

AF0000-B05001<br />

AS2002-050A07<br />

AY2002-W50070<br />

AY2002-050A01<br />

AF0000-B05001<br />

AS2002-050A07<br />

*See page 162 for listing of components included in Base Column Parts Kit.<br />

Includes:<br />

Base Column Parts Kit*, 40cm long column, for bed lengths up to 15cm<br />

Piston Assembly with 1µm frit<br />

Outlet Frit, 1µm<br />

1/16” o.d., 0.020” i.d. Connecting Tube and Fittings<br />

Base Column Parts Kit*, 70cm long column, for bed lengths up to 30cm<br />

Piston Assembly with 1µm frit<br />

Outlet Frit, 1µm<br />

1/16” o.d., 0.020” i.d. Connecting Tube and Fittings<br />

Base Column Parts Kit*, 40cm long column, for bed lengths up to 15cm<br />

Piston Assembly with 1µm frit<br />

Outlet Frit, 1µm<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings<br />

Base Column Parts Kit*, 70cm long column, for bed lengths up to 30cm<br />

Piston Assembly with 1µm frit<br />

Outlet Frit, 1µm<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings<br />

Part No.<br />

SY2002-W25040<br />

SY2002-W25070<br />

SY2002-W50040<br />

SY2002-W50070<br />

more info<br />

Supercritical Fluid Chromatography (SFC)<br />

Supercritical fluids, first discovered in 1879, have been used for extraction applications since the 1950s. The 1980s saw an increase in their<br />

use as mobile phases for supercritical fluid chromatograpy (SFC). The mobile phase most commonly used in SFC is supercritical CO2.<br />

Supercritical CO2 as a mobile phase provides high solubility and high column loading for many substances. In addition, CO2 and other<br />

supercritical fluids have very low viscosity which enables faster separations and extractions. Collection of concentrated product is also<br />

facilitated by the ready evaporation of the mobile phase under ambient conditions.<br />

SFC today is just another type of high-performance chromatography, either normal or reversed phase, ideally suited for the analysis of<br />

thermally labile molecules with low or moderate molecular weight.<br />

Any molecule that will dissolve in methanol or a less polar solvent is a good candidate for SFC. Many strong bases that are difficult to<br />

separate by other techniques separate rapidly and efficiently with good peak shape in SFC.<br />

This technique in recent times has attracted new applications in drug discovery and drug purification because of its speed of separation<br />

and simplicity of fraction collection.<br />

SFC requires columns with hardware and seals designed to withstand higher operating pressures. <strong>Grace</strong>’s Axial SFC columns are<br />

designed to meet these requirements and offer in addition the advantage of a long-life column prepared using proven axial compression<br />

packing techniques.<br />

prep | columns<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

www.discoverysciences.com<br />

167


prep | flash | tlc<br />

Axial SFC Column Components<br />

How to Order Axial SFC Columns<br />

Axial SFC columns can be ordered as a complete kit, as seen<br />

on page 167, or customized selecting the options that best suit<br />

your needs, as shown below. Axial SFC columns are offered<br />

in two lengths, 40cm and 70cm. A 40cm column body can<br />

accommodate up to a 15cm length packed bed and the 70cm<br />

column body can accommodate up to a 30cm length packed<br />

bed.<br />

prep | columns<br />

Each complete column consists of four components:<br />

1. The Base Spring Column Parts Kit includes:<br />

a. Column Body Axial SFC<br />

b. All Seals and O-rings<br />

c. Locking Mechanism<br />

d. Guide Tube<br />

e. Endplate<br />

f. Assembly Hardware<br />

g. Packing Spacers (for 70cm length columns)<br />

2. A Ready-to-Use Piston Assembly consisting of the piston<br />

body, piston frit, PTFE sleeve, and piston seal. The piston<br />

assembly can be ordered with a 1µm or 5µm frit porosity.<br />

3. An Outlet Frit. Choose 1µm or 5µm frit porosity.<br />

4. Tubing and Connectors. Choose tubing with an outer<br />

diameter and bore that suits your needs.<br />

7413<br />

Experienced Axial SFC Column users can build customized Axial SFC Columns by individually selecting the components that<br />

best meet their needs.<br />

Axial SFC Columns<br />

Column Dimensions Description Part No.<br />

25mm i.d.<br />

1. Base Parts Kit Non-Water-Jacketed Axial SFC Column Kit, 40cm long, for bed lengths up to 15cm AY2002-025040<br />

Water-Jacketed Axial SFC Column Kit, 40cm long, for bed lengths up to 15cm<br />

AY2002-W25040<br />

Non-Water-Jacketed Axial SFC Column Kit, 70cm long, for bed lengths up to 30cm<br />

AY2002-025070<br />

Water-Jacketed Axial SFC Column Kit, 70cm long, for bed lengths up to 30cm<br />

AY2002-W25070<br />

2. Piston Assembly Piston Assembly with 1µm frit AY2002-025A01<br />

Piston Assembly with 5µm frit<br />

AY2002-025A02<br />

3. Outlet Frit Outlet Frit, 1µm AF0000-C02501<br />

Outlet Frit, 5µm<br />

AF0000-C02503<br />

4. Tubing and Connectors 1/16” o.d., 0.020” i.d. Connecting Tube and Fittings AF2002-025A06<br />

1/16” o.d., 0.040” i.d. Connecting Tube and Fittings AF2002-025A07<br />

50mm i.d.<br />

1. Base Parts Kit Non-Water-Jacketed Axial SFC Column Kit, 40cm long, for bed lengths up to 15cm AY2002-050040<br />

Water-Jacketed Axial SFC Column Kit, 40cm long, for bed lengths up to 15cm<br />

AY2002-W50040<br />

Non-Water-Jacketed Axial SFC Column Kit, 70cm long, for bed lengths up to 30cm<br />

AY2002-050070<br />

Water-Jacketed Axial SFC Column Kit, 70cm long, for bed lengths up to 30cm<br />

AY2002-W50070<br />

2. Piston Assembly Piston Assembly with 1µm frit AY2002-050A01<br />

Piston Assembly with 5µm frit<br />

AY2002-050A02<br />

3. Outlet Frit Outlet Frit, 1µm AF0000-B05001<br />

Outlet Frit, 5µm<br />

AF0000-B05003<br />

4. Tubing and Connectors 1/16” o.d., 0.040” i.d. Connecting Tube and Fittings AF2002-050A07<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings AF2002-050A08<br />

1/8” o.d., 0.085” i.d. Connecting Tube and Fittings AF2002-050A09<br />

more info<br />

For a listing of the individual parts included in the kits and assemblies above, please refer to page 166.<br />

168 www.discoverysciences.com


prep | flash | tlc<br />

Axial SFC Column Components<br />

Repack Kits for Axial SFC Columns<br />

Each repack kit contains consumable parts for one column repack.<br />

Repack Kit for Spring Columns<br />

Column Dimensions Part No. Description<br />

25mm i.d.<br />

With 1µm Frits<br />

With 5µm Frits<br />

50mm i.d.<br />

With 1µm Frits<br />

With 5µm Frits<br />

AF0000-C02501<br />

AH0000-R025A2<br />

AF0000-D02501<br />

AY2002-025A12<br />

AF0000-C02503<br />

AF0000-D02501<br />

AH0000-R025A2<br />

AY2002-025A13<br />

AF0000-B05001<br />

AH0000-R050A2<br />

AF0000-D05001<br />

AY2002-050A14<br />

AF0000-B05003<br />

AF0000-D05001<br />

AH0000-R050A2<br />

AY2002-050A15<br />

*Components of the Piston Frit Replacement Kit are listed below.<br />

Replacement Parts for Axial SFC Columns<br />

Includes:<br />

Outlet Frit, 1µm<br />

Seal Ring Set for Axial SFC Column Outlet<br />

Outlet Disperser Frit<br />

Piston Frit Replacement Kit*, 1µm<br />

Outlet Frit, 5µm<br />

Outlet Disperser Frit<br />

Seal Ring Set for Axial SFC Column Outlet<br />

Piston Frit Replacement Kit*, 5µm<br />

Outlet Frit, 1µm<br />

Seal Ring Set for Axial SFC Column Outlet<br />

Outlet Disperser Frit<br />

Piston Frit Replacement Kit*, 1µm<br />

Outlet Frit, 5µm<br />

Outlet Disperser Frit<br />

Seal Ring Set for Axial SFC Column Outlet<br />

Piston Frit Replacement Kit*, 5µm<br />

In addition to the repack kits listed above, a full array of replacement parts may be ordered from the list below.<br />

Part No.<br />

AY2002-025A14<br />

AY2002-025A15<br />

AY2002-050A12<br />

AY2002-025A15<br />

prep | columns<br />

Spring Column Replacement Parts<br />

Description For 25mm i.d. For 50mm i.d.<br />

Outlet Disperser Frit AF0000-D02501 AF0000-D05001<br />

Outlet Frit, 1µm AF0000-C02501 AF0000-B05001<br />

Outlet Frit, 5µm AF0000-C02503 AF0000-B05003<br />

Seal Ring Set for Axial SFC Column Outlet AH0000-R025A2 AH0000-R050A2<br />

Replacement Bolts, Nuts, and Washers for Non-Water-Jacketed Column AY2002-025A08 AY2002-050A10<br />

Replacement Botls, Nuts, and Washers for Water-Jacketed Column AY2002-025A11 AY2002-050A13<br />

Threaded Spacer for 40cm Long Column AS2002-025000 AS2002-050000<br />

Threaded Spacer for 70cm Long Column AS2002-025001 AS2002-050001<br />

Threaded Flange AS2002-025002 AS2002-050002<br />

Packing Spacer AS2002-025003 AS2002-050003<br />

Unpacking Spacer for 70cm Long Columns AS2002-025005 AS2002-050005<br />

Piston AY2002-025007 AY2002-050007<br />

Piston Frit Replacement Kit, 1µm; Piston O-ring, spring-loaded seal, PTFE sleeve, 1µm Double-Density Frit AY2002-025A12 AY2002-050A14<br />

Piston Frit Replacement Kit, 5µm; Piston O-ring, spring-loaded seal, PTFE sleeve, 5µm Double-Density Frit AY2002-025A13 AY2002-050A15<br />

Piston Seal for Axial SFC Column AY2002-025011 AY2002-050011<br />

PTFE Sleeve AS2002-025010 AS2002-050010<br />

www.discoverysciences.com<br />

169


prep | flash | tlc<br />

Empty MODcol ® Flanged Columns<br />

• Robust 316 stainless steel construction<br />

• Double seals prevent leaks<br />

• Novel flow distribution ensures high chromotographic performance<br />

Modular in construction and manufactured to the highest standards, these patented stainless steel columns are known for<br />

durability and their special leakproof seal system. A uniform approach to the design of MODcol ® column components is used<br />

across the MODcol ® preparative, semi-preparative and industrial column product lines.<br />

prep | columns<br />

All MODcol ® flanged columns are constructed from high-quality 316 stainless steel alloy and electro-polished to provide the<br />

highest possible corrosion protection and chemical inertness. The flanged construction is rugged and conservatively rated at<br />

2000psig. Column closure is achieved with high-strength bolts and heavy-duty endplates that are engineered to provide long<br />

product life. The simplicity of this design, without threads or other parts that can wear out, makes the hardware reusable and<br />

repackable.<br />

Each empty column kit comes with the following:<br />

• One column body<br />

• One pair of end plates<br />

• Frits, o-rings, and tubing connectors<br />

related products<br />

Custom packing of MODcol ® Flanged Columns is available.<br />

Refer to page 174.<br />

Sizes other than those listed are available on a custom basis. Please contact <strong>Grace</strong> for assistance.<br />

7347<br />

7372<br />

Empty MODcol ® Flanged Column Kits (Complete)<br />

i.d.<br />

Length<br />

5cm Part No. 10cm Part No. 15cm Part No. 25cm Part No. 30cm Part No. 50cm Part No.<br />

25mm FA0000-025005 FA0000-025010 FA0000-025015 FA0000-025025 C C<br />

30mm FA0000-030005 FA0000-030010 FA0000-030015 FA0000-030025 C C<br />

50mm FA0000-050005 FA0000-050010 FA0000-050015 FA0000-050025 FA0000-050030 FA0000-050050<br />

101mm — FA0000-101010 FA0000-101015 FA0000-101025 FA0000-101030 FA0000-101050<br />

C = available as a custom order.<br />

Parts for MODcol ® Flanged Columns<br />

Assembly Hardware<br />

Seal Rings/O-Rings (set)<br />

Disperser Frits (pair)<br />

Bed-Support Frits (pair)*<br />

i.d.<br />

Part No.<br />

Part No.<br />

Part No.<br />

Part No.<br />

25mm AH0000-A02501 AH0000-R025A1 AF0000-D025A1 AF0000-B025Ax<br />

30mm AH0000-A03001 AH0000-R030A1 AF0000-D030A1 AF0000-B030Ax<br />

50mm AH0000-A05001 AH0000-R050A1 AF0000-D050A1 AF0000-B050Ax<br />

101mm AH0000-A10101 AH0000-R101A1 AF0000-D101A1 AF0000-B101Ax<br />

*When specifying the part number for flanged column frits, please indicate the desired porosity by substituting the trailing “x” with: “1” for 1µm, “2” for 2µm, “3” for 5µm, “4” for 10µm.<br />

MODcol ® Mobile Column Stand, Holder, and Tray<br />

i.d.<br />

Part No.<br />

101mm A00000-101000<br />

Stainless Steel Tubing, Fittings, and Connectors<br />

Description<br />

Part No.<br />

1/16” o.d., 0.020” i.d. Connecting Tube and Fittings* AS2002-025A06<br />

1/16” o.d., 0.040” i.d. Connecting Tube and Fittings* AS2002-025A07<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings** AS2002-050A08<br />

1/8” o.d., 0.085” i.d. Connecting Tube and Fittings** AS2002-050A09<br />

*1 union, 1 nut, 1 ferrule, and 2 plugs. Compatible with flanged and spring columns up to 25mm i.d.<br />

**1 union, 1 nut, 1 ferrule, 2 plugs, and 2 female reducers 1/8” to 1/16.” Compatible with flanged and spring columns of 30mm i.d. and greater.<br />

170 www.discoverysciences.com


prep | flash | tlc<br />

Process Scale Columns and Systems by Peak Biotech A/S<br />

<strong>Grace</strong> is a global distributor of Peak Biotech A/S columns and systems. This partnership with Peak extends <strong>Grace</strong>’s column line<br />

to provide customers a completely scalable solution, from pre-packed prep columns to bulk chromatography adsorbents and<br />

process scale columns and systems. The coordination between bulk media and process column manufacturer reduces scale-up<br />

risk. Peak’s products are of the highest quality, and are trusted throughout the pharmaceutical and biotech industry.<br />

Dynamic Axial Compression Columns: 50–1000mm i.d.<br />

Features:<br />

• Easy packing and unpacking<br />

• Uniform distribution system<br />

• Removable frit design for easy cleaning<br />

or replacement<br />

• High performance and reproducibility<br />

• Leak detection system<br />

• No sealing adjustment needed<br />

• Scalable<br />

• Mobile construction up to 300mm<br />

• Ergonomic working positions<br />

High-Pressure Chromatography Systems<br />

Features:<br />

• Gradient performance with high<br />

accuracy<br />

• Fully automated, CFR Part 11 and<br />

GAMP 4 compliant<br />

• Mobile construction<br />

• Complete unit, tested and documented<br />

• Compact and reliable<br />

• Flexible control<br />

• Easy maintenance<br />

• Sanitary design<br />

Column Specifications:<br />

Diameters:<br />

From 50–1000mm<br />

Pressure Rated: To 100 bar<br />

Sealing Materials: PTFE and PEEK<br />

Material of Construction: 1.4404, 1.4435, SS316L,<br />

SAF2205<br />

Construction Code: PED or ASME<br />

System Specifications:<br />

Flow Rates:<br />

Flow Rates:<br />

Pressure Rating:<br />

Gradient Loop:<br />

Inlets:<br />

Sealing Material:<br />

Material of<br />

Construction:<br />

6–5000L/h for medium pressure<br />

6–1000L/h for high pressure<br />

0–20 bar and 0–80 bar<br />

Feedback for NIR, mass or<br />

conductivity<br />

4 buffer inlets, 1 product and<br />

5 fractions<br />

PTFE<br />

1.4404, 1.4435, SS316L<br />

prep | columns<br />

Software Control<br />

Features:<br />

• Based on Siemens PCS 7<br />

• Fully automated<br />

• CFR Part 11 compliant<br />

• GAMP 4 compliant<br />

• Programmed according to S88 standard<br />

• Fully tested and validated<br />

• Flexible control<br />

ordering information<br />

Contact your <strong>Grace</strong> sales representative or customer service<br />

to review the column and system options and custom build your<br />

Peak Biotech system.<br />

related products<br />

Also available from Peak Biotech:<br />

• Slurry Handling Equipment<br />

• Ultra-sonic Baths<br />

• Buffer Systems<br />

• Tanks<br />

• Flanged Columns / mech. compress columns<br />

• Low and medium pressure columns<br />

• Low and medium pressure systems<br />

www.discoverysciences.com<br />

171


prep | flash | tlc<br />

Multipacker ® Packing Stations<br />

• Axial packing for high efficiency<br />

• Identicle, high performing columns every time<br />

• Easy to use<br />

• Pack multiple columns on demand<br />

• Economically priced<br />

Multipacker ® instruments are easy-to-use high-performance<br />

packing stations specifically designed for packing Spring<br />

Columns. Three separate instruments are available for<br />

packing 25mm i.d., 50mm i.d., and 101mm i.d. columns.<br />

Their ease of operation and short cycle times provide a<br />

self-contained versatile column-packing solution.<br />

prep | column packing<br />

Spring Column hardware offers outstanding convenience<br />

and flexibility when used with Multipacker ® instruments.<br />

The ability to vary bed length continuously up to 30cm and<br />

the advantages of the Spring-driven axial compression<br />

mechanism provide a high-performance adaptive solution<br />

for both product development and process chromatography.<br />

Furthermore, compared to traditional column packing<br />

processes, Spring Column packing requires significantly<br />

less adsorbent per column because the bed is formed from<br />

the entire quantity of adsorbent introduced into the column,<br />

without wastage. More columns can be packed from the<br />

same batch of medium, reducing concerns about lot-tolot<br />

variations. Also, because adsorbent requirements are<br />

reduced, the cost of a Multipacker ® instrument is recovered<br />

quickly.<br />

Once packed, Spring Column units are independent and<br />

maintain axial compression when used separately from the<br />

Multipacker ® instrument. Consequently, one Multipacker ®<br />

instrument can be used to maintain an entire fleet of Spring<br />

Column modules. For the first time, chromatographers have<br />

the ability to pack columns on demand and quickly respond to<br />

in-house column needs.<br />

25 and 50mm i.d. Multipacker ® Instruments.<br />

7403<br />

Multipacker ® instruments provide several unique advantages.<br />

You have the ability to pack columns when and where they<br />

are needed. You save money with every column packed and<br />

less adsorbent is required. You have control of bed length and<br />

column volume, and columns can easily be unpacked, with<br />

recovery of adsorbent, and repacked in a matter of minutes.<br />

A Multipacker ® axial-compression system is able to pack<br />

columns at low pressures, so less robust media can be<br />

protected from damage and their performance preserved.<br />

Reduced mechanical damage to adsorbent with a<br />

Multipacker ® instrument makes it the perfect match for<br />

delicate, non-silica-based media.<br />

Unlike column-packing systems that use awkward hand<br />

pumps and can require hours for column packing, Spring<br />

Column packing takes only minutes and operates with the<br />

push of a button. Multipacker ® instruments use modular<br />

construction that makes them lightweight and easily<br />

assembled or disassembled. Key components are produced<br />

using advanced aluminum casting techniques that reduce<br />

manufacturing costs and provide high strength and reliability.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

related products<br />

Refer to pages 162–169 for more information on Spring<br />

Columns for use with Multipacker ® packing stations.<br />

7412<br />

172 www.discoverysciences.com


prep | flash | tlc<br />

Multipacker ® Packing Stations<br />

The World’s Most Innovative Preparative Column Packing System<br />

Multipacker ® Series 2002 Instrument for 25mm i.d. Spring Column Modules<br />

Part No.<br />

IM2002-025IM1<br />

Multipacker ® Series 2002 Instrument for 50mm i.d. Spring Column Modules<br />

Part No.<br />

IM2002-050IM1<br />

Multipacker ® Series 2002 Two-Instrument Bundle for 25mm i.d. and 50mm i.d. Spring Column Modules<br />

Part No.<br />

IM2002-025050<br />

Multipacker ® Instrument for 101mm i.d. Spring Column Modules<br />

Part No.<br />

IM2002-101IM1<br />

more info<br />

For a short web animation and video demonstration,<br />

visit the MODcol ® section of our website at<br />

www.discoverysciences.com/modcol.<br />

prep | column packing<br />

related products<br />

Multipacker ® instruments require Spring Column hardware,<br />

purchased separately, for column packing. See listing on<br />

pages 162–169.<br />

101mm<br />

Multipacker ®<br />

Instrument.<br />

7404<br />

www.discoverysciences.com<br />

173


prep | flash | tlc<br />

Column Packing Services<br />

• Experience packing hundreds of types of media, <strong>Grace</strong><br />

and non-<strong>Grace</strong> media<br />

• Packing service available for Spring Columns and<br />

Flanged Column hardware<br />

• Column Efficiency Report (CER) provided with each<br />

column<br />

Since 1982 <strong>Grace</strong>’s MODcol ® division has successfully<br />

packed thousands of preparative columns with hundreds<br />

of different media. Proven proprietary procedures together<br />

with quality hardware allow <strong>Grace</strong> to provide preparative<br />

columns with high efficiency, excellent resolution and low<br />

backpressure.<br />

Column Efficiency Report (CER)<br />

prep | column packing<br />

The result of each packing is validated and presented to the<br />

customer in the form of a Column Efficiency Report (CER).<br />

This report summarizes the product, the testing protocol, and<br />

presents the chromatographic data in a graphical and tabular<br />

format that is easy to understand. Only when the customer<br />

approves the result is the column shipped.<br />

<strong>Grace</strong> supplies end users with the world’s only ready-to-use<br />

axial compression system, the prepacked Spring Column<br />

unit. Empty Spring Column hardware can be ordered and,<br />

combined with media purchased from <strong>Grace</strong> or supplied by<br />

the end user and the packing services shown below, delivered<br />

as a ready-to-use product. <strong>Grace</strong> packs Spring Column<br />

units using the Multipacker ® instruments described earlier in<br />

this section. Purchasing a prepacked Spring Column unit is<br />

a great way to evaluate the performance of this novel product<br />

under real-world conditions. Unpacking and repacking the<br />

Spring Column unit must be done by <strong>Grace</strong> or on a user’s<br />

own Multipacker ® instrument.<br />

Each custom-packed Spring Column unit is validated as<br />

described above.<br />

Please note that the 40cm long Spring Column body can<br />

accommodate bed lengths up to15cm, and the 70cm-long<br />

Spring Column body can accommodate a maximum bed<br />

length of 30cm. For intermediate beds, please specifiy the<br />

length to be packed by modifying the last two digits of the part<br />

number shown, e.g., for a 50mm i.d. x 40cm Spring Column<br />

unit packed to a bed height of 12cm, specify part number<br />

PS0000-050412. For information concerning the amount of<br />

media that will be required to pack a particular bed length<br />

please call your local sales person, distributor, or <strong>Grace</strong><br />

technical support.<br />

7389<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

Column Packing Services for Flanged Columns<br />

i.d.<br />

Length<br />

5cm 10cm 15cm 25cm 30cm 50cm<br />

25mm PA0000-025005 PA0000-025010 PA0000-025015 PA0000-025025 C C<br />

30mm PA0000-030005 PA0000-030010 PA0000-030015 PA0000-030025 C C<br />

50mm PA0000-050005 PA0000-050010 PA0000-050015 PA0000-050025 PA0000-050030 PA0000-050050<br />

101mm — PA0000-101010 PA0000-101015 PA0000-101025 PA0000-101030 PA0000-101050<br />

C = available as custom.<br />

Column Packing Services for Spring Column and Axial SFC Column<br />

Column i.d.<br />

Bed Length<br />

5cm 10cm 15cm 25cm 30cm<br />

25mm x 40cm PS0000-025405 PS0000-025410 PS0000-025415 — —<br />

25mm x 70cm PS0000-025705 PS0000-025710 PS0000-025715 PS0000-025725 PS0000-025730<br />

50mm x 40cm PS0000-050405 PS0000-050410 PS0000-050415 — —<br />

50mm x 70cm PS0000-050005 PS0000-050710 PS0000-050715 PS0000-050725 PS0000-050730<br />

101mm x 40cm PS0000-101405 PS0000-101410 PS0000-101415 — —<br />

101mm x 70cm PS0000-101005 PS0000-101710 PS0000-101715 PS0000-101725 PS0000-101730<br />

174 www.discoverysciences.com


prep | flash | tlc<br />

Bulk Chromatographic Media Introduction<br />

<strong>Grace</strong>–The Foremost Name in Silica Materials Science<br />

Davison Chemical, forerunner of the <strong>Grace</strong> Davison Silica Products business, was founded in Baltimore,<br />

Maryland in 1832. Silica gel, was patented in 1919 and in the early 1920s Davison commercialized silica gel<br />

and began developing many new applications such as air drying, refrigeration, and packaging desiccants.<br />

<strong>Grace</strong> Davison has continued to expand applications for silica and has long been recognized for superior<br />

technical service, strong applications technology, and global customer support.<br />

Quality, Consistency, and Proven Performance<br />

<strong>Grace</strong> Davison’s materials science expertise assures highquality<br />

and consistency in its silica-based media products.<br />

Our bulk adsorbents are used to purify a number of FDA<br />

approved biopharmaceuticals and we provide regulatory<br />

support data for GMP applications.<br />

All of our plants are ISO-9001 certified and<br />

our Hesperia, California plant is compliant with<br />

the IPEC-PQG GMP guidelines.<br />

Unmatched Capacity, Global Reach, Expert Support<br />

Our global presence and manufacturing capacity enables us to supply hundreds of tons of silica every year to some of the largest<br />

biotechnology and pharmaceutical manufacturing facilities. When you rely on <strong>Grace</strong>, you can count on consistent product quality,<br />

timely delivery and expert technical support.<br />

<strong>Grace</strong> Key Bulk Media Families<br />

Scalable Solutions: Silica and Hardware<br />

<strong>Grace</strong> manufactures a range of completely scalable silica<br />

media. To help select the appropriate media for your<br />

applicaiton, we describe key media families and highlight<br />

unique phases within these families. Each family highlighted<br />

is available up to ton quantities for process scale applications.<br />

<strong>Grace</strong> also provides a range of columns and skid systems<br />

from preparative to process scale that ensure optimal<br />

performance of our media (pages 162–174). Please contact<br />

your <strong>Grace</strong> sales representative to discuss a complete<br />

solution for your preparative or process scale needs.<br />

<strong>Grace</strong>Alpha<br />

A new silica generation.<br />

<strong>Grace</strong>Alpha combines increased column efficiencies<br />

and resolution with high loading capacity. A new silica<br />

(patent pending) makes this possible by combining a<br />

high-porosity surface, with a dense core, increasing<br />

mass transfer while yielding a mechanically robust<br />

particle.<br />

Applications: High purity spherical silica suitable for<br />

peptides and small molecules (2000 molecular weight)<br />

Differentiated Phases: C18, C8, C4<br />

Specifications: Spheroidal silica, polymerically and<br />

monomerically bonded, endcapped, 300Å pore size,<br />

10μm–30μm<br />

Formats: Capillary, Microbore, Expedite, Rocket,<br />

Solvent-Reducer, Analytical, Prep, Bulk Media<br />

Davisil ®<br />

Excellent mechanical and structural properties,<br />

Davisil ® silica are globally recognized for their<br />

consistency and reliability.<br />

The Davisil ® silica line offers a range of pore diameters<br />

from 30Å to 2500Å with high surface area and narrow<br />

particle size distributions to offer the chromatographer<br />

the ultimate in selection and performance.<br />

Applications: Economical granular silica for small<br />

molecules to large biomolecules<br />

prep | media<br />

Differentiated Phases: Silica, C18, Cyano, Diol, Amino<br />

Specifications: Granular silica, 30–2500Å pore sizes,<br />

10μm–2000μm particle sizes<br />

Format: Bulk Media<br />

www.discoverysciences.com<br />

175


prep | flash | tlc<br />

<strong>Grace</strong>Alpha Media<br />

A New Silica Generation<br />

new<br />

• Increased loading capacity<br />

• High resolution<br />

• High efficiency DAC packing<br />

• Produced in facility complaint to IPEC-PQG GMP<br />

guidelines<br />

• Ultimately reproducible<br />

• Mechanically strong<br />

<strong>Grace</strong>Alpha Silica Specifications<br />

Pore Size:<br />

120Å<br />

Pore Volume:<br />

0.95mL/g<br />

Surface Area: 325m 2 /g<br />

Chemical Purity:<br />


prep | flash | tlc<br />

Vydac ® Media<br />

300Å RP Protein Purification Pioneer<br />

Pioneered by <strong>Grace</strong> and produced by a unique<br />

process based on purified oranosilicate starting materials,<br />

Vydac ® silicas are well defined, high purity, totally porous<br />

separation media that meet the most demanding needs of<br />

preparative and process scale users. Proven in over two<br />

decades of applications for protein, peptide, and nucleic<br />

acid separations, Vydac ® 300Å reversed-phase media<br />

have excellent selectivity and reproducibility. Bulk Vydac ®<br />

adsorbents incorporate bonded phase chemistries identical<br />

to those in Vydac ® brand analytical and prep HPLC columns,<br />

thereby assuring economical method development and<br />

reliable, dependable scale-up for preparative and process<br />

chromatographic applications.<br />

Vydac ® TP 300A Silica Specifications<br />

Pore Size:<br />

300Å<br />

Pore Volume:<br />

0.6mL/g<br />

Surface Area: 90m 2 /g<br />

Particle Shape:<br />

Spheroidal<br />

Vydac ® 300Å Media<br />

MS<br />

TP<br />

Butylsilane Octylsilane Octadecylsilane Butylsilane Octylsilane Octadecylsilane Octadecylsilane Diphenylsilane<br />

Bonded Chemistry<br />

C4<br />

214MS<br />

C8<br />

208MS<br />

C18<br />

218MS<br />

C4<br />

214TP<br />

C8<br />

208TP<br />

C18<br />

218TP<br />

C18 monomeric<br />

238TP 219TP<br />

Silica<br />

101TP<br />

10–15µm Particles 214MSB1015 208MSB1015 218MSB1015 214TPB1015 208TPB1015 218TPB1015 238TPB1015 219TPB1015 101TPB1015<br />

15–20µm Particles 214MSB1520 208MSB1520 218MSB1520 214TPB1520 208TPB1520 218TPB1520 238TPB1520 219TPB1520 101TPB1520<br />

20–30µm Particles 214MSB2030 208MSB2030 218MSB2030 214TPB2030 208TPB2030 218TPB2030 238TPB2030 219TPB2030 101TPB2030<br />

Available in 10g increments.<br />

tech tip<br />

Vydac ® MS vs. Vydac ® TP<br />

Both phases are based on the same high purity 300Å silica. However, MS undergoes an additional treatment prior to bonding that<br />

reduces the residual polar activity of the silica surface. For many applications this results in improved resolution and an increase<br />

in protein recovery.<br />

prep | media<br />

Two-Stage Purification of a Synthetic 135-mer<br />

Although generally recommended for oligonucleotides<br />

up to 75 bases, Vydac ® 214TP columns have been used<br />

to purify much longer synthetic oligonucleotides. Here<br />

a 135-mer is purified by two stages of chromatography<br />

on a 214TP column—the first with the 5'-dimethoxytrityl<br />

protecting group still attached, causing strong retention,<br />

and the second after removal of the trityl group.<br />

<br />

<br />

<br />

Column: Vydac ® 214TP1010 C4, 10µm,10 x 250mm<br />

Flow Rate: 5mL/min<br />

Mobile Phase: A: 0.1 M Triethylammonium Acetate, pH 7.0<br />

B: Acetonitrile<br />

Gradient: Crude: 0 to 60% B from 5 to 40min<br />

Deprotected: 0 to 20% B from 5 to 25min<br />

Detector: UV at 260nm<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Data courtesy of Joseph Kosmoski and Dr. Michael Smerdon, Dept. of Biochemistry and Biophysics, Washington State University, Pullman, WA, USA<br />

related products<br />

Looking for Vydac ® analytical columns?<br />

See pages 84–95.<br />

www.discoverysciences.com<br />

177


prep | flash | tlc<br />

Davisil ® Media<br />

• High surface area<br />

• Tight particle size distribution<br />

• Wide range of pore sizes (30–2500Å) and particle sizes (10–2000µm) available<br />

• Relied on for over 25 years<br />

Recognized worldwide as media of high purity, Davisil ® silica is the cornerstone of <strong>Grace</strong>’s offering<br />

of silica media products. Consisting of irregularly shaped particles with excellent mechanical and<br />

structural properties, Davisil ® silicas are versatile, consistent, and reliable. They are ideal for HPLC,<br />

solid phase extraction, flash chromatography, and scale-up to industrial process applications.<br />

Higher Performance<br />

Davisil ® silica’s chemical and structural properties are<br />

optimized for chromatographic performance. Tight control<br />

of these properties from raw material to finished product<br />

distinguishes Davisil ® silica from the competition.*<br />

High Surface Area for Increased Loading Capacity<br />

Synthetic Intermediate Purification<br />

prep | media<br />

Company Surface Area Bulk Density Surface Area of 1L Column<br />

<strong>Grace</strong> 550m 2 /g 420g/L 231,000m 2 /L<br />

X 515m 2 /g 430g/L 221,450m 2 /L<br />

Y 460m 2 /g 430g/L 197,800m 2 /L<br />

Z 450m 2 /g 450g/L 189,000m 2 /L<br />

High Purity Silica to Reduce Unwanted Interactions<br />

and Contamination<br />

Company Mg Ca<br />

<strong>Grace</strong> 25ppm 19ppm<br />

X 27ppm 207ppm<br />

Y 119ppm 793ppm<br />

Z 212ppm 1775ppm<br />

Tight Particle Size Distribution to Optimize<br />

Efficiency and Pressure Drop<br />

diff. Volume (%)<br />

18<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

GRACE<br />

Most Narrow Particle<br />

Size Distribution<br />

100%<br />

Pet Ether<br />

Sample:<br />

1g Reaction Products<br />

Column:<br />

50 x 500mm Minutes<br />

Column Packing: Davisil ® LC60Å 20 – 45µm<br />

Mobile Phase: See Chromatogram<br />

Flow Rate: 175mL/min (535cm/hr)<br />

Detection: UV at 254nm<br />

Davisil ® silica purification of a schiff base from a crude reaction<br />

mixture containing aldehyde, amine and other by-products. The good<br />

separation and loading capacity shown at the pilot scale allowed<br />

scale-up to a 300mm diameter column producing over 90g of purified<br />

product per run.<br />

Global Technical Support<br />

80/20<br />

Pet/Diethyl Ether<br />

0 10 20 30 Min.<br />

To assist customers, <strong>Grace</strong> offers advice, assistance or<br />

laboratory trials for intended process-scale use. Our field<br />

representatives can arrange for such support when required,<br />

as well as discuss our ability to customize grades tailored to<br />

your requirements.<br />

0<br />

1 10<br />

100<br />

Particle size (µm)<br />

<strong>Grace</strong> X Y Z<br />

*All comparative data generated on chromatographic silica labeled 60Å, 40–63µm.<br />

178 www.discoverysciences.com


prep | flash | tlc<br />

Davisil ® Media<br />

Greater Selection<br />

A wide range of Davisil ® silica grades are available to meet<br />

your performance and economic requirements. The selection<br />

guide in this catalog will help you choose the best grade for<br />

your application.<br />

• Available in both normal phase bare silica and various<br />

bonding chemistries (C18, Amino, Diol, Cyano) for<br />

alternative selectivity<br />

• Wide selection of distinct pore diameters (30–2500Å) for<br />

separation of various MW sizes<br />

• Available from 500g to multi-ton quantities<br />

Davisil ® normal-phase silica functions through hydrophilic<br />

interactions, with more polar compounds generally retained<br />

longer. This makes it ideally suited for purification of:<br />

Chemical Synthesis<br />

Intermediates<br />

Silica<br />

Look for this icon on products from <strong>Grace</strong> using<br />

Davisil ® silica, such as TLC plates and SPE/<br />

Flash cartridges, to experience the same great<br />

performance.<br />

Predictable Scale-Up<br />

Today we manufacture hundreds of tons of Davisil ®<br />

chromatographic silica per year in multi-ton lots. Our<br />

manufacturing is at scale, so your manufacturing can be<br />

at scale. In scaling up, you can be confident that Davisil ®<br />

chromatographic silica will yeild consistent performance<br />

as particle size is increased.<br />

Oils and Fats<br />

prep | media<br />

CAPACITY FACTOR (k’)<br />

3<br />

2.8<br />

2.6<br />

2.4<br />

2.2<br />

2<br />

1.8<br />

1.6<br />

1.4<br />

1.2<br />

1<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

0 15<br />

Dinitrobenzene<br />

Cholesterol<br />

N. Methylanine<br />

Phenol<br />

Benzaldehyde<br />

25 35 45<br />

Particle Size (µm)<br />

Uniform capacity (k ’ ) and selectivity (k ’ ) factors across all particle<br />

sizes for predictable scale-up.<br />

Unbeatable Product Reliability<br />

Natural Products<br />

(vitamins, flavors,<br />

fragrances, etc.)<br />

Manufactured for over 25 years, Davisil ® chromatographic<br />

silica is one of the world’s most widely used chromatography<br />

sorbents.<br />

Surface Area<br />

& Pore Volume:<br />

+/-10% lot to lot<br />

Produced at two ISO-9001 certified facilities under strict<br />

QC controls from raw material to finished product insures<br />

high lot-to-lot reproducibility.<br />

www.discoverysciences.com<br />

179


prep | flash | tlc<br />

Davisil ® Media<br />

Selection Guide<br />

Many types of column packings are suitable for a given application. The diagram below is intended for general guidance<br />

to the chromatographer. By following each of the three paths in sequence, the proper packing media is selected.<br />

It should be noted that <strong>Grace</strong> offers other media to complement the Davisil ® packings in many of these applications.<br />

Step 1 Step 2 Step 3<br />

Sample<br />

Molecular<br />

Weight<br />

Sample<br />

Separation Difficulty<br />

& System Pressure<br />

Limitations**<br />

Sample<br />

Solubility<br />

prep | media<br />


prep | flash | tlc<br />

Davisil ® Media<br />

Below is a listing of our more popular Davisil ® silica grades.<br />

For a complete listing request brochure 538.<br />

Unbonded Silica<br />

APS Particle Size Davisil ® Silica Grade Pk Size Part No.<br />

30Å 50–100µm 921 25kg 5101737<br />

75–150µm 923 1 25kg 5138973<br />

5lb 5139002<br />

72 x 10g 5139003<br />

576 x 10g 5139001<br />

75–700µm 12 2 25kg 5139180<br />

250–500µm 15 3 25kg 5101744<br />

60Å 10µm 710NW 20kg 5136220<br />

16–20µm 631 25kg 5101778<br />

40–63µm LC60Å 40–63µm 25kg 5054993<br />

5kg 5098468<br />

1kg 5134312<br />

60–200µm LC60Å 60–200µm 25kg 5007446<br />

5kg 5134295<br />

1kg 5134311<br />

200–500µm LC60Å 200–500µm 25kg 5022298<br />

150Å 16–24µm LC150Å 16–24µm 25kg 5018962<br />

35–70µm LC150Å 35–70µm 25kg 5057993<br />

5kg 5134294<br />

1kg 5134299<br />

60–200µm LC150Å 60–200µm 25kg 5134770<br />

5kg 5134293<br />

1kg 5134298<br />

250Å 40–63µm LC250Å 40–63µm 15kg 5134301<br />

2.5kg 5134292<br />

60–200µm LC250Å 60–200µm 15kg 5134300<br />

2.5kg 5134291<br />

500Å 35–70µm XWP500Å 35–70µm 20kg 5030057<br />

5kg 5108711<br />

90–130µm XWP500Å 90–130µm 20kg 5058842<br />

5kg 5134305<br />

100–300µm XWP500Å 100–300µm 20kg 5057050<br />

1000Å 16–24µm XWP1000Å 16–24µm 20kg 5134302<br />

5kg 5016756<br />

35–70µm XWP1000Å 35–70µm 20kg 5034754<br />

5kg 5134304<br />

90–130µm XWP1000Å 90–130µm 20kg 5093501<br />

5kg 5134303<br />

1500Å 16–24µm XWP1500Å 16–24µm 18kg 5070159<br />

90–130µm XWP1500Å 90–130µm 18kg 5045916<br />

2500Å 90–130µm XWP2500Å 90–130µm 5kg 5107451<br />

ASTM or EPA Method<br />

1<br />

Grade 923 ASTM D1319: Petroleum Products by FIA<br />

ASTM D2549: Aromatics/Non-Aromatics from Oils<br />

EPA Method 1664: N-Hexane Extraction Method<br />

2<br />

Grade 12 ASTM D2007: Rubber Extender/ Processing Oils<br />

3<br />

Grade 15 EPA Method 601/624: Purgeable Halocarbons<br />

Bonded Silica<br />

APS Bonded Phase Particle Size Davisil ® Silica Grade Pk Size Part No.<br />

60Å C18 10µm 710NC18E 250g 5135418<br />

1kg 5135305<br />

35–60µm 633NC18E 250g 5135414<br />

1kg 5134095<br />

Cyano 10µm 710NCNE 250g 5135419<br />

1kg 5134223<br />

35–60µm 633NCNE 250g 5135415<br />

1kg 5134224<br />

Diol 10µm 710N2OH 250g 5135417<br />

1kg 5135303<br />

35–60µm 633N2OH 250g 5135413<br />

1kg 5135302<br />

Amino 10µm 710NNH2 250g 5135420<br />

1kg 5134682<br />

35–60µm 633NNH2 250g 5135416<br />

1kg 5134096<br />

related products<br />

Matching Davisil ® Silica TLC plates for easy method development.<br />

Davisil ® Silica TLC Plates<br />

Description Layer Thickness Qty. Part No.<br />

Hard Layer, Organic Binder, Fluorescent Indicator, 254nm<br />

Scored, 4, 5 x 20cm Sections<br />

20 x 20cm 250µm 25 8617580<br />

Scored, 8, 2.5 x 10cm Sections<br />

10 x 20cm 250µm 25 8617610<br />

7174<br />

prep | media<br />

related products<br />

Column Hardware and Packing<br />

Equipment also available.<br />

See pages 162–174.<br />

related products<br />

Looking for additional TLC products?<br />

See pages 188–198.<br />

www.discoverysciences.com<br />

181


prep | flash | tlc<br />

prep | accessories<br />

Stainless Steel Tubing and Fittings<br />

Tubing and Fitting Kits for MODcol ® Flanged and Spring Columns<br />

Tubing and Fitting Kits<br />

Description<br />

Part No.<br />

1/16” o.d., 0.020” i.d. Connecting Tube and Fittings* AS2002-025A06<br />

1/16” o.d., 0.040” i.d. Connecting Tube and Fittings* AS2002-025A07<br />

1/8” o.d., 0.060” i.d. Connecting Tube and Fittings** AS2002-050A08<br />

1/8” o.d., 0.085” i.d. Connecting Tube and Fittings** AS2002-050A09<br />

*1 union, 1 nut, 1 ferrule, and 2 plugs. Compatible with flanged and Spring Columns up to 25mm i.d.<br />

**1 union, 1 nut, 1 ferrule, 2 plugs, and 2 female reducers 1/8” to 1/16.” Compatible with flanged and Spring Columns of 30mm i.d. and greater.<br />

Valco ® High-Pressure Fittings<br />

Valco ® Fitting Specifications<br />

Material:<br />

Max. Temperature: 500ºC<br />

Max. Pressure:<br />

Typical Use:<br />

A<br />

Valco ® Unions<br />

G<br />

J<br />

316 Stainless Steel<br />

10,000psig<br />

Valco ® Nuts and Ferrules<br />

Valco ® Unions<br />

High-Pressure Tubing Connections<br />

5431 5697<br />

B<br />

Valco ® Nuts and Ferrules<br />

Graphic Description Qty. Part No.<br />

Stainless Steel Nuts<br />

A 1/16" Nut 10 306121<br />

A 1/8" Nut 10 306151<br />

Stainless Steel Ferrules<br />

B 1/16" (Type 316) 10 30646<br />

B 1/8" (Type 316) 10 30647<br />

5511 5512<br />

I<br />

5520<br />

5521 5550<br />

Graphic Size Bore Part No.<br />

Internal Unions<br />

G 1/16" 0.50mm 30714<br />

G 1/16" 0.75mm 30715<br />

G 1/16" 1/16" 45835<br />

G 1/8" 2.0mm 30718<br />

G 1/8" 1/8" 30719<br />

External Unions<br />

H 1/8" 2.0mm 30731<br />

Internal Reducing Unions<br />

I 1/8" to 1/16" 0.25mm 30746<br />

I 1/8" to 1/16" 0.75mm 45850<br />

I 1/4" to 1/8" 1/8" 30755<br />

External/Internal Reducing Unions<br />

J 1/8" to 1/16" 1/16" 30761<br />

J 1/4" to 1/8" 2.0mm 30765<br />

J 1/4" to 1/8" 1/8" 30766<br />

Column Endfittings<br />

K 1/4" to 1/16" 2.1mm 45905<br />

K 1/4" to 1/16" 3.0mm 45907<br />

H<br />

K<br />

Hi-EFF Grade<br />

Stainless Steel Tubing<br />

Hi-EFF grade stainless steel<br />

tubing is especially tempered<br />

for easy bending and is<br />

washed with acetone to remove any residual materials.<br />

Hi-EFF Stainless Steel Tubing Specifications<br />

Material:<br />

316 Series Stainless Steel<br />

Maximum Temperature: 500°C<br />

Maximum Pressure: Varies according to i.d.*<br />

Typical Use:<br />

High-Pressure Plumbing<br />

*Request datasheet 3005D for more information.<br />

Hi-EFF Grade Stainless Steel Tubing<br />

Per Ft** Per Meter 50ft Coil<br />

o.d.<br />

i.d.<br />

Part No. Part No. Part No.<br />

Type 316 Stainless Steel<br />

1/8" (3.18mm) 0.085" (2.16mm) 30105 30107 30109<br />

1/4" (6.35mm) 0.210" (5.33mm) 30307 30308 30309<br />

**Minimum tubing order is 3'.<br />

Stainless Steel Tubing<br />

This Stainless Steel Tubing is the same high quality as the<br />

Hi-EFF grade, but has not been washed with acetone.<br />

Stainless Steel Tubing Specifications<br />

Material:<br />

316 Series Stainless Steel<br />

Maximum Temperature: 500°C<br />

Maximum Pressure: Varies according to i.d.*<br />

Typical Use:<br />

High-Pressure Plumbing<br />

*Request datasheet 3005D for more information.<br />

Stainless Steel Tubing<br />

Per Ft**<br />

Part No.<br />

related products<br />

For additional information on<br />

HPLC fittings see pages 112–122,<br />

and for tubing information see pages<br />

384–391.<br />

Per Meter<br />

Part No.<br />

50ft Coil<br />

Part No.<br />

200ft Coil<br />

Part No.<br />

o.d.<br />

i.d.<br />

Type 316 Stainless Steel<br />

1/16" 0.020" 3002100 300230 3002 300220<br />

(1.59mm) (0.51mm)<br />

0.040" 30031 30033 3003 —<br />

(1.02mm)<br />

**Minimum tubing order is 3'.<br />

5537<br />

182 www.discoverysciences.com


prep | flash | tlc<br />

Pumps, Injectors, and Switching Valves<br />

Model 627 Preparative HPLC Pump<br />

Flow rate range of 0.1mL/min to 100.0mL/min.<br />

Ideal for Scale-up Work, Semi-Prep and<br />

Preparative HPLC<br />

• Dual piston mechanism for pulse-free operation<br />

• Built-in low dead volume pulse dampener<br />

• Self-flushing pump head for longer seal life<br />

• Isocratic or high-pressure binary gradient<br />

The Model 627 Preparative Pump delivers the accuracy and<br />

precision of a standard analytical pump at flow rates up to<br />

100mL/min. Consistent flow rates and pressures minimize<br />

the potential for column damage. The 627 pump is available<br />

in 316 stainless steel or biocompatible PEEK.<br />

Buy one pump now and upgrade to a binary system later by<br />

purchasing a second pump and a high-pressure gradient kit.<br />

Model 627 HPLC Pump Specifications<br />

Max. Operating Pressure: 4000psig (both SS and PEEK)<br />

Flow Rate Range:<br />

0.1–100.0 mL/min<br />

Flow Rate Precision: 0.5% RSD<br />

Flow Accuracy: ±2.0%<br />

Gradient Mixing Mode: High-Pressure<br />

Gradient Profiles:<br />

Programmable Multi-step<br />

Gradient Programming: 10 methods with up to 100 lines per method<br />

Dimensions:<br />

6" H x 11" W x 18" D<br />

(15cm H x 26cm W x 46cm D)<br />

Weight:<br />

35lb (16kg)<br />

Warranty:<br />

1-year parts, 1-year labor, excluding seals<br />

and check valves<br />

Model 627 Preparative Pump<br />

Description<br />

Part No.<br />

Isocratic System<br />

PEEK, 85-265VAC, 47-63Hz 627150<br />

Stainless Steel, 85-265VAC, 47-63Hz 627250<br />

Binary Gradient System<br />

(Includes 2 pumps, system controller, mixing tee, tubing and fittings)<br />

PEEK, 85-265VAC, 47-63Hz 627350<br />

Stainless Steel, 85-265VAC, 47-63Hz 627450<br />

Kits and Accessories<br />

Description<br />

Part No.<br />

Accessories<br />

High-pressure Gradient Kit, PEEK<br />

105625<br />

(Includes controller, mixing tee, fittings, and tubing)<br />

High-pressure Gradient Kit, Stainless Steel<br />

105628<br />

(Includes controller, mixing tee, fittings, and tubing)<br />

Replacement Parts<br />

Piston Seal Kit 120681<br />

Piston 121504<br />

Check Valve Kit, Stainless Steel 120679<br />

Check Valve Kit, Metal-Free 060141<br />

Note: All replacement parts kits contain parts for one pump head only.<br />

6774<br />

Rheodyne ® Model 3725 Prep-Scale Injectors<br />

• Sample range 100µL to 20mL<br />

• Flow rates from 10 to<br />

800mL/min<br />

• Uses 16-gauge needle<br />

• 1.0mm (0.04") flow passages<br />

These injectors are used with<br />

preparative HPLC columns from<br />

1 to 10cm diameter. They have<br />

the ease of use and versatility<br />

of Rheodyne’s analytical-scale sample injectors, plus the<br />

capacity for large sample volumes and flow rates.<br />

The Model 3725 Valves are available in stainless steel or<br />

PEEK, and with a built-in position sensing switch (Model<br />

3725i-038 or 3725i). Each model is supplied with a 10mL loop<br />

and 1/8" fittings must be used. An optional port adapter can<br />

be used to connect 1/16" tubing. Suitable for pressures up to<br />

5000psig.<br />

Rheodyne ® Prep-Scale Sample Injectors<br />

Description Version Part No.<br />

Prep Injection Valves<br />

Model 3725 PEEK 37250<br />

Model 3725-038 SS 37255<br />

Model 3725i-038 SS 37256<br />

Accessory<br />

Port Adapter for 1/16" tubing — 600760<br />

Rheodyne ® Manual Switching Valves<br />

• Inexpensive manual<br />

switching valve<br />

• Wide-bore version for prep<br />

Rheodyne ® HPLC Switching<br />

Valves offer an endless variety<br />

of ways to simplify switching and<br />

injecting. Standard valves are<br />

supplied with 0.024" internal flow<br />

passages and are suitable for use<br />

with analytical and semi-preparative applications. Large bore<br />

valves with 0.040" internal flow passages are available for<br />

use at high flow rates (greater than 50mL/min) 7000psig<br />

pressure limit.<br />

A spring detent mechanism included in the six-position<br />

selection valve permits full circle rotation in either direction<br />

and ensures that the rotor “falls into” each of the six positions<br />

at the precise 60° spacing.<br />

Rheodyne ® Manual Switching Valves<br />

Description Version Bore Part No.<br />

2-Position Valves<br />

6-Port* SS Standard 7000RV<br />

6-Port* SS Large Bore 7000L<br />

10-Port* SS Standard 7610400<br />

10-Port* PEEK Standard 7610600<br />

3-Way SS Standard 7030RV<br />

3-Way SS Large Bore 7030L<br />

4-Way SS Standard 7040RV<br />

4-Way SS Large Bore 7040L<br />

Multi-Position Valves<br />

6-Position 6-Port SS Standard 7060RV<br />

6-Position 6-Port SS Large Bore 7060L<br />

*5000psig pressure rating for 2-position 6-Port and 10-port.<br />

5495<br />

5619<br />

www.discoverysciences.com<br />

prep | accessories<br />

183


prep | flash | tlc<br />

Flash Chromatography Introduction<br />

The technique of flash chromatography has advanced<br />

considerably since it began in the 1970s with self-packed<br />

glass columns that relied on gravity for flow. Instrumentation<br />

today automates and speeds the purification, and pre-packed<br />

disposable cartridges eliminate the time spent packing.<br />

However, the one area of flash chromatography that has seen<br />

little advancement is the heart of the separation, the silica<br />

Experiment<br />

Loading Capacity Study<br />

The loading capacity of a <strong>Grace</strong>Resolv 40g cartridge and<br />

a leading competitor’s 40g cartridge were compared using<br />

the purification of a sample mixture containing Dimethyl<br />

Phthalate and Toluene as an example. The testing determined<br />

maximum loading capacity with baseline resolution.<br />

Flash Silica Technology<br />

Most cartridges today are packed with the same 40–63µm<br />

irregular shaped silica that was used for self-packed glass<br />

columns in the 1970s. The benefit of this type of silica is<br />

that it is inexpensive and generates low backpressure while<br />

providing a marginal level of resolution. <strong>Grace</strong>, as a silica<br />

manufacturer, supplies this same grade of silica to many of<br />

the flash manufacturers. However, as a silica manufacturer,<br />

and a company with a breadth of chromatography products<br />

and knowledge, <strong>Grace</strong> is advancing the field of flash<br />

chromatography by introducing innovative silica and cartridge<br />

manufacturing.<br />

Figure 1.<br />

Loading Capacity Comparison<br />

<strong>Grace</strong>Resolv<br />

0 1 2 3 4 5 6 Min.<br />

Amount of<br />

Sample Loaded<br />

0.48g<br />

3.84g<br />

6.72g<br />

9.12g<br />

9.6g<br />

<strong>Grace</strong>Resolv Silica<br />

flash<br />

<strong>Grace</strong> developed a new grade of Davisil ® silica<br />

that dramatically increases resolution and<br />

capacity without an increase in backpressure.<br />

Silica<br />

The silica used in the <strong>Grace</strong>Resolv cartridges<br />

is smaller in particle size than traditional flash<br />

silicas but has a more narrow particle size distribution and<br />

very few fine particles. As in HPLC, the smaller particles<br />

generate greater efficiencies in the packed column, increasing<br />

resolution. The narrow particle size distribution allows the<br />

cartridge to be packed with higher efficiencies and the<br />

reduction in fines allows all of this to happen without a change<br />

in backpressure.<br />

Competitor<br />

0 1 2 3 4 5 6 Min.<br />

Cartridge: 40g silica cartridge<br />

Sample: Peak 1: Toluene<br />

Peak 2: Dimethyl Phthalate<br />

Mobile Phase: Hexane:Ethyl Acetate (70:30)<br />

Flow Rate: 40mL/min<br />

Detector: UV at 254nm<br />

<strong>Grace</strong>Resolv silica also undergoes a proprietary process to<br />

remove metals from the silica surface. Surface metals cause<br />

mixed-mode interactions that lead to peak tailing and a loss of<br />

resolution. <strong>Grace</strong>Resolv silica has 50% less surface metals<br />

than standard irregular silica used today in flash cartridges.<br />

This makes a dramatic difference in resolution especially for<br />

metal chelator compounds.<br />

<strong>Grace</strong>Resolv High-Resolution Flash<br />

Cartridges<br />

The advantage of the silica used in our cartridges is<br />

guaranteed with a rigorous quality assurance program.<br />

Each <strong>Grace</strong>Resolv cartridge undergoes over 15 tests,<br />

from silica to packed cartridge, to ensure unvarying lot-to-lot<br />

performance. A chromatographic test is performed to ensure<br />

that the columns are well packed and meet our efficiency,<br />

resolution, and peak symmetry specifications.<br />

Figure 2.<br />

Maximum Loading Capacity with Baseline Resolution<br />

<strong>Grace</strong>Resolv 9.12g<br />

0 1 2 3 4 5 6 Min.<br />

Competitor 3.84g<br />

7280<br />

0 1 2 3 4 5 6 Min.<br />

Results<br />

This experiment demonstrates how the improved silica<br />

technology in <strong>Grace</strong>Resolv cartridges and efficient column<br />

packing improve the resolution of the separation and allow<br />

higher sample loading at high product purity.<br />

184 www.discoverysciences.com


prep | flash | tlc<br />

<strong>Grace</strong>Resolv High-Resolution Flash Cartridges<br />

• High resolution<br />

• Increased loading capacity<br />

• Reproducible performance<br />

• Compatible with all flash instruments<br />

• Novel silica<br />

<strong>Grace</strong>’s 30 years of chromatography experience<br />

combined with 80 years of silica manufacturing<br />

expertise has yielded the ideal flash cartridge,<br />

Silica<br />

<strong>Grace</strong>Resolv. <strong>Grace</strong>Resolv cartridges<br />

are packed with a new grade of Davisil ®<br />

silica designed to maximize performance of today’s flash<br />

instruments.<br />

Increase Resolution and Product Purity with <strong>Grace</strong>Resolv Flash Cartridges<br />

(patent pending)<br />

1.00<br />

0.90<br />

Leading Competitor Cartridge<br />

1. Acetylacetone<br />

H 3 C<br />

CH 3<br />

1.00<br />

0.90<br />

1<br />

<strong>Grace</strong>Resolv Flash Cartridges<br />

0.80<br />

0.70<br />

0.60<br />

compound<br />

not<br />

resolved<br />

2<br />

O O<br />

2. Methyl Paraben<br />

O<br />

HO<br />

0.80<br />

0.70<br />

0.60<br />

2<br />

pure<br />

fraction<br />

completely<br />

resolved<br />

0.50<br />

OCH 3<br />

0.50<br />

0.40<br />

0.30<br />

0.20<br />

0.10<br />

0.00<br />

0<br />

1<br />

1<br />

2<br />

3 4 Min.<br />

Cartridge Size:<br />

Instrument:<br />

Sample:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

12g<br />

Combiflash ® Companion ® /TS<br />

Acetylacetone, Methyl<br />

Paraben dissolved in 95:5<br />

Hexane: IPA with 1% TFA<br />

80:20 Hexane:Ethyl Acetate<br />

36mL/min<br />

UV at 254nm<br />

0.40<br />

0.30<br />

0.20<br />

0.10<br />

0.00<br />

0<br />

1<br />

2<br />

3 4 Min.<br />

flash<br />

What Gives <strong>Grace</strong>Resolv Cartridges Their Superior Performance?<br />

1. Small Particle Size<br />

A smaller particle size increases resolution. Tighter particle<br />

size distribution and minimal fines keep backpressure low.<br />

See Figure 1.<br />

2. High Purity Silica<br />

<strong>Grace</strong>’s flash silica undergoes a proprietary process to<br />

reduce metals from the silica surface by over 50%. Metals<br />

cause peak tailing and reduce resolution especially for metal<br />

chelator compounds.<br />

Percentage of Metal Content<br />

Silica Fe2O3 Na2O Al2O3 SO4<br />

<strong>Grace</strong>Resolv 0.001 0.01 0.02 0.001<br />

Competitive Standard 0.005 0.07 0.05 0.01<br />

Particle Size Distribution<br />

<strong>Grace</strong>Resolv Flash Cartridges<br />

Standard Flash Silica<br />

1 10 100 1000 2000µm<br />

Measured by Malvern ® Mastersizer ® 2000.<br />

Figure 1<br />

3. Efficient Column Packing<br />

A tightly packed silica bed increases cartridge efficiency and<br />

prevents voids and channeling that cause poor resolution.<br />

Flash chromatography, like HPLC, benefits greatly from<br />

optimized packing procedures. See Figure 2.<br />

4. Strict Quality Control<br />

<strong>Grace</strong>Resolv cartridges are characterized with over<br />

15 tests, from the silica to the packed cartridge, to ensure<br />

unvarying lot-to-lot performance. A quality assurance<br />

certificate is provided with each box of cartridges.<br />

0.06<br />

0.04<br />

0.02<br />

0.00<br />

0<br />

Figure 2<br />

Cartridge Efficiency Chromatogram<br />

6600 plates/meter<br />

1700 plates/meter<br />

5 10 15 Min.<br />

Results from identical silica packed into a 330g cartridge.<br />

www.discoverysciences.com<br />

185


prep | flash | tlc<br />

<strong>Grace</strong>Resolv Silica Cartridges—Luer Endfittings<br />

Directly Connect to Isco ® Systems<br />

7278<br />

<strong>Grace</strong>Resolv Cartridges—Luer Endfittings<br />

flash<br />

<strong>Grace</strong>Resolv Cartridges—Luer Endfittings<br />

Cartridge Size Qty. Part No.<br />

<strong>Grace</strong>Resolv 4g 20/pk 8618502<br />

<strong>Grace</strong>Resolv 12g 20/pk 8618522<br />

<strong>Grace</strong>Resolv 40g 15/pk 8618521<br />

<strong>Grace</strong>Resolv 80g 12/pk 8618520<br />

<strong>Grace</strong>Resolv 120g 10/pk 8618509<br />

<strong>Grace</strong>Resolv 330g 4/pk 8618523<br />

Solid Loaders<br />

Empty*<br />

Silica Filled<br />

Description Qty. Part No. Qty. Part No.<br />

Luer Slip Solid Loader—Isco ® Compatible<br />

5g (12mL cartridge) 100/pk 5142050 20/pk 5142035<br />

25g (60mL cartridge) 100/pk 5142051 16/pk 5142034<br />

Luer Lock Solid Loader—Biotage ® Compatible<br />

5g (12mL cartridge) 100/pk 8618941 20/pk 8618942<br />

25g (60mL cartridge) 100/pk 8618943 16/pk 8618944<br />

*Empty solid loaders come with two 20µm frits.<br />

Luer Lock Solid Loader<br />

7376 7375<br />

Luer Slip Solid Loader<br />

Adapters to Connect to Biotage ® Systems<br />

Support Rings<br />

7350<br />

Adapters<br />

Support Rings<br />

Description<br />

Part No.<br />

Pack contains adapters for five sizes (4, 12, 40, 80, 120g) 8618945<br />

Adapters<br />

Description<br />

Part No.<br />

Male and female luer solvent line connectors 8618940<br />

Adjustable Plunger<br />

Description<br />

Part No.<br />

5g (12mL cartridge) 8619011<br />

25g (60mL cartridge) 8619010<br />

7338<br />

tech tip<br />

To connect a <strong>Grace</strong>Resolv cartridge to<br />

a Biotage ® instrument, simply connect<br />

the adapters to the inlet and outlet<br />

side of the cartridge and attach to the<br />

instrument’s tubing. The cartridge then<br />

fits on the Biotage ® instrument with<br />

the appropriate support ring.<br />

If needed, a luer lock solid loader<br />

can also be used with the<br />

adjustable plunger.<br />

Adjustable Plunger<br />

7402<br />

186 www.discoverysciences.com


prep | flash | tlc<br />

<strong>Grace</strong>Resolv Silica Cartridges—SPE Style<br />

Directly Connect to FlashMaster Systems<br />

<strong>Grace</strong>Resolv Cartridges—SPE Style<br />

Cartridge Size Qty. Part No.<br />

<strong>Grace</strong>Resolv 5g/25mL 20/pk 8618508<br />

<strong>Grace</strong>Resolv 10g/70mL 16/pk 8618507<br />

<strong>Grace</strong>Resolv 25g/150mL 10/pk 8618506<br />

<strong>Grace</strong>Resolv 50g/150mL 10/pk 8618505<br />

<strong>Grace</strong>Resolv 70g/150mL 10/pk 8618504<br />

<strong>Grace</strong>Resolv 100g/276mL 12/pk 8618503<br />

<strong>Grace</strong>Resolv Cartridges—SPE Style<br />

7349<br />

<strong>Grace</strong>Resolv Silica TLC Plates and Tanks<br />

• TLC plates use the same silica as the <strong>Grace</strong>Resolv<br />

cartridges for direct method development<br />

• Plates are pre-scored in 5 x 20cm sections for easy size<br />

customization<br />

flash<br />

<strong>Grace</strong>Resolv Silica TLC Plates<br />

Description Thickness Qty. Part No.<br />

Hard Layer, Organic Binder, Fluorescent Indicator, 254nm<br />

20 x 20cm (Scored into four 5 x 20cm sections) 250µm 25 8618900<br />

Rectangular TLC Tanks with Glass Lid<br />

Description<br />

Part No.<br />

Standard Tank for 20 x 20cm Plates, (27x24x7cm), (10.5x10x3") 2108359<br />

Davisil ® Bulk Silica<br />

Standard flash grade silica available for solid loading,<br />

scale-up to large-scale process applications, and<br />

self-packing of flash cartridges.<br />

TLC Plates<br />

Rectangular TLC Tank<br />

5369 5346<br />

more info<br />

Additional TLC accessories and Davisil ® silica grades are<br />

available from <strong>Grace</strong>. Refer to the TLC section on pages 188–198<br />

and Media section on pages 175–181.<br />

Silica<br />

Davisil ® Bulk Silica<br />

APS Particle Size Davisil ® Grade Pk Size Part No.<br />

60Å 40–63µm LC60Å 40–63µm 25 kg 5054993<br />

5 kg 5098468<br />

1 kg 5134312<br />

60–200µm LC60Å 60–200µm 25 kg 5007446<br />

5 kg 5134295<br />

1 kg 5134311<br />

150Å 35–70µm LC150Å 35–70µm 25 kg 5057993<br />

5 kg 5134294<br />

1 kg 5134299<br />

60–200µm LC150Å 60–200µm 25kg 5134770<br />

5 kg 5134293<br />

1 kg 5134298<br />

7115<br />

Davisil ® Bulk Bonded Silica<br />

APS Bonded Phase Particle Size Davisil ® Grade Pk Size Part No.<br />

60Å C18 35–70µm 633NC18E 250g 5135414<br />

1kg 5134095<br />

Cyano 35–70µm 633NCNE 250g 5135415<br />

1kg 5134224<br />

Diol 35–70µm 633N2OH 250g 5135413<br />

1kg 5135302<br />

Amino 35–70µm 633NNH2 250g 5135416<br />

1kg 5134096<br />

www.discoverysciences.com<br />

187


prep | flash | tlc<br />

tlc<br />

TLC Introduction<br />

Thin Layer Chromatography to Preparative<br />

Chromatography<br />

One of the first steps in scale-up of preparative liquid<br />

chromatography separations is selection of an appropriate<br />

mobile phase. Two methods are commonly used to<br />

determine the proper mobile phase composition: Thin<br />

Layer Chromatography (TLC) or High Performance Liquid<br />

Chromatography (HPLC). The use of TLC will be discussed<br />

here to deal with the successful correlation between the TLC<br />

separation to the preparative silica column.<br />

TLC is a liquid-solid adsorption technique where the mobile<br />

phase ascends the thin layer of stationary phase coated onto<br />

a backing support such as glass by capillary action. There<br />

is a similar relationship to column chromatography where<br />

the solvent travels down through the column’s adsorbent.<br />

The similar relationship allows TLC to be a rapid method for<br />

determining solvent composition for preparative separations.<br />

Steps for Method Development<br />

Choose Stationary Phase<br />

Choose a scalable TLC plate, preferably that has an identical<br />

media as the preparative column. Choose between normal<br />

and reverse phase based on sample polarity and solubility.<br />

Choose a Mobile Phase<br />

Criteria for Choosing a Preparative Solvent<br />

• Solubility<br />

• Affinity<br />

• Resolution<br />

1. Solubility<br />

Many solvent systems provide the minimal solubility for the<br />

sample, but to elute a sample from a column the mobile<br />

phase must have a greater solubility for the sample, as the<br />

sample concentration is usually very high. When possible, it<br />

is best to dissolve the sample in the mobile phase. The first<br />

step in solvent selection is determination of the solubility of<br />

the sample. The desired mobile phase would provide the<br />

greatest solubility, while providing affinity for the sample on<br />

the stationary phase.<br />

Solvent Solubility Screening Table<br />

Water<br />

Methanol<br />

Ethanol<br />

Acetone<br />

Diethyl Ether<br />

Ethyl Acetate<br />

Dichloromethane<br />

Toluene<br />

Chloroform<br />

Cyclohexane<br />

Petroleum Ether<br />

Hexane<br />

Increasing Polarity<br />

2. Affinity<br />

To achieve a separation, the sample must have a relatively<br />

equal affinity for the solvent and the packing material. If the<br />

sample has a higher affinity for the stationary phase than the<br />

solvent, the sample will remain at the origin (Rf value will be<br />

too low).<br />

3. Resolution<br />

Resolution is improved by optimizing the affinity between<br />

sample, solvent, and support. The optimum solvent for<br />

separating two or more compounds will maximize the<br />

difference in the compounds. Most TLC and preparative<br />

mobile phase systems contain a polar solvent and a<br />

chromatographically dissimilar less-polar solvent. As a<br />

guide for method development, a substitution in the polar<br />

solvent often results in a change in resolution, while a change<br />

in the less-polar solvent results primarily in a change in Rf<br />

of the sample components. The table below shows some<br />

common tendencies of various functional groups to adsorb<br />

onto the silica.<br />

Affinity of Functional Groups for Silica Gel<br />

-NH2 Amine<br />

-COOH Carboxylic Acid<br />

-COH Alcohol<br />

-CONH2 Amide<br />

-C=O Carbonyl<br />

-C=-CO2R Ester<br />

-C-O-C Ether<br />

-C1 Halocarbons<br />

-CC- Hydrocarbons<br />

Select Visualization Technique<br />

Once a mobile phase is selected, visualization techniques<br />

will need to be determined. Common techniques include<br />

SWUV, I2 /SWUV, I2 /KI for Nitrogen containing compounds,<br />

H2SO4/LWUV, H2SO4/PMA for non-nitrogen containing<br />

compounds.<br />

Perform TLC Analysis<br />

Increasing Affinity<br />

Look up the affinity for the type of compound as well as<br />

the solvent strengths to find a starting point for method<br />

development or look up a reference from a similar structure,<br />

then adjust the mobile phase composition to adjust the Rf. It<br />

is common to try 3–6 solvent systems for the first round of<br />

method development. Review the results after visualization<br />

and adjust the Rf if necessary, increase the separation and<br />

evaluate visualization techniques to make sure you are seeing<br />

all necessary compounds.<br />

Optimizing TLC Separations for Preparative<br />

Separations<br />

The optimum separation of compounds by TLC is usually<br />

achieved when Rf values are between 0.3–0.5.<br />

Rf = Distance from origin to center of spot<br />

Distance from origin to solvent front<br />

Generally, adjusting the compound’s Rf between 0.3–0.5 is<br />

done first for a TLC separation. For scale-up to preparative<br />

separations, the TLC solvent system’s polarity must be<br />

decreased to lower the Rf between 0.15–0.35. This Rf range<br />

is optimal for a preparative separation, in terms of sample<br />

load, resolution, residence time, and solvent usage.<br />

Determination of Column Volumes (C.V.)<br />

The equation C.V. = 1/ Rf relates the TLC values and the<br />

preparative LC column volumes to elute each component.<br />

This equation is only a guideline and the relationship<br />

between the Rf values and the column volume will vary in<br />

use. Generally, the LC column volumes will be equal to or<br />

less than the calculated values. The elution volume will also<br />

be dependent upon the sample load and solvent used to<br />

solubilize the sample.<br />

188 www.discoverysciences.com


prep | flash | tlc<br />

TLC Plates<br />

Davisil ® Silica TLC Plates<br />

• Made with the same Davisil ® silica as sold in<br />

bulk for easy method development<br />

• Scored to customize to your plate size preference<br />

Silica<br />

Davisil ® Silica TLC Plates<br />

Description Layer Thickness Qty. Part No.<br />

Hard Layer, Organic Binder, Fluorescent Indicator, 254nm<br />

Scored, 4, 5 x 20cm Sections<br />

20 x 20cm 250µm 25 8617580<br />

Scored, 8, 2.5 x 10cm Sections<br />

10 x 20cm 250µm 25 8617610<br />

Alltech ® Prep-Screen TLC Plates<br />

• Made with the 10–12µm spherical silica gel used for<br />

Alltech ® prep-HPLC cartridge columns<br />

• Available in both Econosphere silica gel and C18<br />

(reversed-phase) bonded versions<br />

Prep-Screen HPTLC Plates help to optimize sample<br />

separation parameters for use in preparative HPLC. These<br />

plates allow a quick, inexpensive preview of sample traits in<br />

various mobile phase systems prior to HPLC analysis. The<br />

adsorbent is the same Econosphere silica or C18 used in<br />

Alltech packed HPLC columns.<br />

<strong>Grace</strong>Resolv Silica TLC Plates<br />

• Made with the same high-purity Davisil ® silica as used<br />

in the <strong>Grace</strong>Resolv flash cartridges for easy method<br />

development<br />

• Scored to customize to your plate size preference<br />

<strong>Grace</strong>Resolv Silica TLC Plates<br />

Description Layer Thickness Qty. Part No.<br />

Hard Layer, Organic Binder, Fluorescent Indicator, 254nm<br />

Scored, 4, 5 x 20cm Sections<br />

20 x 20cm 250µm 25 8618900<br />

Prep-Screen C18<br />

3<br />

2<br />

1<br />

7087<br />

1. Progesterone<br />

2. Testosterone<br />

3. Hydrocortisone<br />

Prep-Screen Sol. System:<br />

Methanol:Water (70:30)<br />

HPLC Sol. System:<br />

Methanol:Water (70:30)<br />

Econo-Prep HPLC<br />

3<br />

7065<br />

2<br />

1<br />

tlc<br />

Prep Screen HPTLC Plates<br />

Description Qty. Part No.<br />

Prep-Screen HPTLC Plates, 10 x 10cm, 200µm Layer<br />

Silica Gel, 10µm Spherical Adsorbent 10 16328<br />

C18, 10µm Spherical Adsorbent 10 16332<br />

3179<br />

<strong>Grace</strong> has a large<br />

selection of TLC plates<br />

to suit your separation<br />

needs.<br />

5369<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

related products<br />

See pages 194–198 for tanks, sprayers, applicators, and other<br />

TLC accessories.<br />

www.discoverysciences.com<br />

189


prep | flash | tlc<br />

TLC Plates<br />

Alltech ® Prekotes<br />

• High purity silica gel for increased sensitivity<br />

• Controlled particle size for faster separations and<br />

improved resolution (>80% in 6–15µm range)<br />

• Precoated plates provide convenience and superior<br />

layer quality<br />

Adsorbosil ® HPTLC Plates<br />

• 150µm layer thickness for fast, high resolution separations<br />

• Smooth surface for noise-free densitometry<br />

HPTLC with Organic Binder<br />

• Organic binder makes an abrasion-resistant layer<br />

• Use up to 80% water in the solvent system<br />

• Maximum temp for charring is 150°C<br />

Adsorbosil ® -Plus<br />

Silica Gel H<br />

(Soft Layer)<br />

+ CaSO 4<br />

Adsorbosil ® -Plus 1<br />

Silica Gel G<br />

(Soft Layer)<br />

HPTLC with Inorganic Binder<br />

• Allows use of 100% water in the solvent system<br />

• Use when strong charring is required<br />

tlc<br />

Soft Layer<br />

• Contains no organic binders<br />

• Sample zones are easy to remove for further analysis<br />

Soft Layer Adsorbosil ® Prekotes<br />

Description Qty. Part No.<br />

Soft Layer Prekotes, Glass-Backed<br />

Conventional, 250µm Layer Thickness, 20 x 20cm<br />

Adsorbosil ® -Plus 25 16384<br />

Adsorbosil ® -Plus P* 25 16376<br />

Adsorbosil ® -Plus 1 25 16330<br />

Adsorbosil ® -Plus 1 P* 25 16322<br />

Preadsorbent, 250µm Layer Thickness, 20 x 20cm<br />

Adsorbosil ® -Plus 1 25 16370<br />

Adsorbosil ® -Plus 1 P* 25 16371<br />

Preadsorbent/Prechannel, 250µm Layer, 20 x 20cm<br />

Adsorbosil ® -Plus 1 25 16374<br />

Adsorbosil ® -Plus 1 P* 25 16375<br />

Preparative, 500µm Layer Thickness, 20 x 20cm<br />

Adsorbosil ® -Plus 1 25 16492<br />

*P = With Fluorescent Indicator, 254 wavelength.<br />

Hard Layer<br />

• Contains a proprietary inorganic binder to add abrasion<br />

resistance to layer<br />

• Use when strong charring is required for visualization<br />

• Write on layer with pencil or felt pen<br />

• Sample zones can be removed for further analysis<br />

High-Performance TLC Plates<br />

Description Qty. Part No.<br />

Adsorbosil ® -Plus Plates with Organic Binder, 10 x 10cm<br />

Adsorbosil ® -Plus HPTLC 25 16405<br />

Adsorbosil ® -Plus P, HPTLC, F254 25 16420<br />

Adsorbosil ® -Plus HPTLC with<br />

25 16402<br />

Preadsorbent Zone<br />

Adsorbosil ® -Plus P HPTLC with<br />

25 16403<br />

Preadsorbent Zone, F254<br />

Adsorbosil ® -Plus 1 Plates with Inorganic Binder, 10 x 10cm<br />

Adsorbosil ® -Plus 1 HPTLC 25 16400<br />

Adsorbosil ® -Plus 1P HPTLC, with F254<br />

UV Indicator<br />

25 16401<br />

Reversed-Phase HPTLC Plates<br />

• Coated with non-polar, C18 chemically bonded support<br />

• Cross-linked organic polymer binder makes an abrasion<br />

resistant layer and a smooth surface<br />

• Use to separate mixtures of lipophilic components,<br />

hydrocarbons, fats and waxes, fat soluble vitamins<br />

or steroids<br />

Fatty Acid Separation<br />

1. Methyl Oleate<br />

2. Methyl Linoleate<br />

3. Methyl Linolenate<br />

7088<br />

Hard Layer Adsorbosil ® Prekotes<br />

Description Qty. Part No.<br />

Hard Layer Prekotes, Glass-Backed<br />

Conventional, 250µm Layer Thickness, 20 x 20cm<br />

Adsorbosil ® -Plus 1 25 16324<br />

Adsorbosil ® -Plus 1 P* 25 16326<br />

Preadsorbent, 250µm Layer Thickness, 20 x 20cm<br />

Adsorbosil ® -Plus 1 25 16316<br />

Adsorbosil ® -Plus 1 P* 25 16317<br />

Preadsorbent/Prechannel, 250µm Layer, 20 x 20cm<br />

Adsorbosil ® -Plus 1 25 16380<br />

Adsorbosil ® -Plus 1 P* 25 16381<br />

*P = With Fluorescent Indicator, 254 wavelength.<br />

1 2 3<br />

TLC Plate: Adsorbosil ® RP HPTLC (Part No. 16314)<br />

Sol. System: Acetonitrile:Acetic Acid:Water (70:10:1)<br />

Development Time: 25min<br />

Visualization: Iodine Vapor<br />

High-Performance TLC Plates<br />

Description Qty. Part No.<br />

Reversed-Phase C18 HPTLC, 150µm Layer Thickness<br />

Adsorbosil ® RP HPTLC, 10 x 10cm 25 16314<br />

Adsorbosil ® RP HPTLC Plates with F254, 25 16315<br />

10 x 10cm<br />

Adsorbosil ® RP HPTLC Plates, Prescored, 25 16318<br />

10 x 20cm<br />

Adsorbosil ® RP HPTLC Plates, Prescored,<br />

with F254, 10 x 20cm<br />

25 16319<br />

190 www.discoverysciences.com


prep | flash | tlc<br />

TLC Plates<br />

Macherey-Nagel<br />

Silica Gel Plates<br />

• 60Å pore size<br />

• Particle size, 5 to 17µm<br />

• Binder is organic, stable in most organic solvents and<br />

aggressive detection reagents<br />

ADAMANT Silica Layers for TLC<br />

• Increased UV brilliance for increased detection sensitivity<br />

• Extremely hard, dust-free surface<br />

• Optimized particle size distribution for improved<br />

separation efficiency<br />

• Ideal for trace analyses<br />

Glass-Backed Macherey-Nagel TLC Plates<br />

Description Size Layer Qty. Part No.<br />

Silica Gel Plates, Glass-Backed<br />

Conventional Layers, Silica Gel 60<br />

SIL G-25 5 x 10cm 250µm 50 809017<br />

SIL G-25 5 x 20cm 250µm 100 809011<br />

SIL G-25 20 x 20cm 250µm 25 809013<br />

SIL G-25 UV254 5 x 20cm 250µm 100 809021<br />

SIL G-25 UV254 20 x 20cm 250µm 25 809023<br />

SIL G-25 UV254+366 20 x 20cm 250µm 25 809123<br />

Preparative Layers<br />

SIL G-100 UV254 20 x 20cm 1000µm 15 809063<br />

SIL G-200 UV254 20 x 20cm 2000µm 12 809083<br />

ADAMANT Glass-Backed Plates<br />

Description Size Layer Qty. Part No.<br />

ADAMANT UV254 2.5 x 7.5cm 250µm 100 821005<br />

ADAMANT UV254 10 x 10cm 250µm 25 821020<br />

ADAMANT UV254 10 x 20cm 250µm 50 821025<br />

ADAMANT UV254 20 x 20cm 250µm 25 821030<br />

Nano-Series HPTLC Plates<br />

• Particle size, 2–10µm<br />

• Higher speed<br />

• Better resolution and sensitivity than regular TLC plates<br />

Specialty Plates<br />

• Silica Gel and Cellulose—Specific for separation of<br />

food preservatives<br />

• Silica Gel—Specific for aflatoxin analysis<br />

• Aluminum Oxide—pH 9 with 60Å pore size,<br />

surface area = 200m 2 /gram<br />

Specialty Plates<br />

Description Size Layer Qty. Part No.<br />

Specialty Plates, Glass-Backed<br />

Silica Gel and Cellulose — Mixed Layer<br />

SILCEL-Mix-25 UV254 20 x 20cm 250µm 25 810043<br />

Silica Gel Highly Purified with Gypsum<br />

SIL G-25 HR 20 x 20cm 250µm 25 809033<br />

SIL G-25 HR UV254 20 x 20cm 250µm 25 809043<br />

Aluminum Oxide, Basic<br />

ALOX-25 UV254 20 x 20cm 250µm 25 807023<br />

ALOX-100 UV254 20 x 20cm 1000µm 15 807033<br />

related products<br />

Performing flash separations?<br />

See <strong>Grace</strong>Resolv flash consumable product line on<br />

pages 184–187.<br />

Nano-SIL HPTLC Plates<br />

Description Size Layer Qty. Part No.<br />

Nano-Series HPTLC Plates, Glass-Backed<br />

Silica Gel 60<br />

Nano-SIL-20 10 x 20cm 200µm 50 811013<br />

Nano-SIL-20/UV254 10 x 20cm 200µm 50 811023<br />

Nano-Series HPTLC Plates, Aluminum-Backed*<br />

Silica Gel 60<br />

Nano-SIL G 20 x 20cm 200µm 25 818141<br />

Nano-SIL G/UV254 20 x 20cm 200µm 25 818143<br />

*Do not use with mineral acids or concentrated ammonia.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

related products<br />

See pages 194–198 for tanks, sprayers, applicators, and other<br />

TLC accessories.<br />

tlc<br />

www.discoverysciences.com<br />

191


prep | flash | tlc<br />

TLC Plates<br />

Macherey-Nagel Polygram ® Series<br />

Silica Gel 60<br />

• SIL G and SIL N layers have different binders and show<br />

different separation characteristics<br />

Cellulose, Avicel-Microcrystalline<br />

Cellulose MN 300—Native Fibrous Cellulose<br />

• Fibers are 2–20µm in length<br />

Hybrid Plates<br />

• “Wettable” RP plate<br />

• For both reversed- and normal-phase chromatography<br />

• Determine polarity by eluent selection<br />

• Activate layer at 110–115°C prior to use<br />

• Particle size of 2–10µm for improved separations<br />

tlc<br />

Cellulose, Ion-Exchanger<br />

• DEAE carries positive charges at neutral and acidic pH<br />

• Use DEAE to separate proteins, enzymes, and hormones<br />

• Use PEI to analyze nucleic acids<br />

Polyamide 6<br />

• Specific for separation of dansyl and DNP amino acids<br />

Polygram ® Flexible-Backed TLC Plates<br />

Description Size Layer Qty. Part No.<br />

Polyester-Backed TLC Plates<br />

Silica Gel 60<br />

SIL G 20 x 20cm 250µm 25 805013<br />

SIL G/UV254 4 x 8cm 250µm 50 805021<br />

SIL G/UV 254 20 x 20cm 250µm 25 805023<br />

SIL N-HR/UV254 20 x 20cm 200µm 25 804023<br />

Cellulose Plates<br />

Cellulose MN 400, Avicel-Microcrystalline Cellulose<br />

CEL 400 20 x 20cm 100µm 25 801113<br />

CEL 400 UV254 20 x 20cm 100µm 25 801123<br />

Cellulose MN 300<br />

CEL 300 20 x 20cm 100µm 25 801013<br />

CEL 300 UV254 20 x 20cm 100µm 25 801023<br />

Cellulose, Ion-Exchanger<br />

CEL 300 DEAE 20 x 20cm 100µm 25 801073<br />

CEL 300 PEI* 20 x 20cm 100µm 25 801053<br />

CEL 300 PEI/UV254 20 x 20cm 100µm 25 801063<br />

Specialty Polyester-Backed Plates<br />

Polyamide 6<br />

POLYAMIDE 6 20 x 20cm 100µm 25 803013<br />

POLYAMIDE 6 UV254 20 x 20cm 100µm 25 803023<br />

Aluminum Oxide, Basic, 20µm Particle Size<br />

ALOX N/UV254 20 x 20cm 200µm 25 802023<br />

ALOX N/UV254 4 x 8cm 200µm 50 802021<br />

Aluminum Oxide, Basic, pH 9, Aluminum-Backed<br />

ALOX N 20 x 20cm 200µm 25 818013<br />

ALOX N/UV254 20 x 20cm 200µm 25 818023<br />

*PEI plates must be refrigerated.<br />

Hybrid TLC Plates<br />

Description Layer Qty. Part No.<br />

Silica Gel RP18/UV254s* Plates, Aluminum-Backed<br />

4 x 8cm 150µm 50 818144<br />

5 x 20cm 150µm 50 818145<br />

20 x 20cm 150µm 25 818146<br />

*Acid-resistant fluorescent indicator.<br />

Chiralplate †<br />

• Separates optically active isomers based on ligand<br />

exchange<br />

• Ready-to-use, requires no solvent pretreatment<br />

†<br />

Chiralplate was developed in cooperation with Degussa AG, Hanau, Germany.<br />

Chiralplate TLC Plates<br />

Description Layer Qty. Part No.<br />

Chiralplate, Glass-Backed<br />

5 x 20cm 250µm 50 811057<br />

10 x 20cm 250µm 4 811056<br />

10 x 20cm 250µm 25 811055<br />

20 x 20cm 250µm 25 811058<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

related products<br />

See pages 194–198 for tanks, sprayers, applicators, and other<br />

TLC accessories.<br />

192 www.discoverysciences.com


prep | flash | tlc<br />

Analtech TLC Plates<br />

Silica Gel H and HF Uniplates<br />

• Soft Layer<br />

– Contains no organic binder<br />

– Contains no calcium sulfate binder<br />

• Hard Layer<br />

– Contains an organic binder<br />

– 80% water resistant<br />

– Visualization by charring up to 150°C<br />

Silica Gel G and GF Uniplates<br />

• Calcium Sulfate Binder<br />

• Soft Layer<br />

– Contains no organic binder<br />

• Hard Layer<br />

– Contains an inorganic binder<br />

– 100% water resistant<br />

– Visualization with strong charring reagents<br />

– Abrasion resistant<br />

Silica Gel H and HF Uniplates<br />

Layer<br />

H<br />

HF*<br />

Description<br />

Thickness Qty. Part No. Part No.<br />

Soft Layer, No Binders<br />

Conventional<br />

20 x 20cm 250µm 25 710011 720011<br />

10 x 20cm 250µm 25 710021 7200210<br />

Scored, Four 5 x 20cm Sections<br />

20 x 20cm 250µm 25 710511 720511<br />

Preparative Uniplates<br />

20 x 20cm 500µm 25 710012 720012<br />

Hard Layer, Organic Binder<br />

Conventional<br />

20 x 20cm 250µm 25 746011 747011<br />

10 x 20cm 250µm 25 746021 747021<br />

Scored, Four 5 x 20cm Sections or Eight, 2.5 x 10cm Sections<br />

20 x 20cm 250µm 25 746511 747511<br />

10 x 20cm 250µm 25 746521 747521<br />

*F-Fluorescent Indicator, 254nm.<br />

HPTLC Uniplates<br />

• Smooth surface gives a high signal-to-noise ratio for<br />

increased sensitivity and precision<br />

• High resolution separations in five minutes<br />

• Ideal for densitometric scanning<br />

HPTLC Uniplates<br />

Description<br />

Layer<br />

Thickness Qty. Part No.<br />

HPTLC Silica Gel with Inorganic Binder<br />

10 x 10cm, HP-GHL 150µm 25 756077<br />

10 x 10cm, HP-GHLF* 150µm 25 757077<br />

HPTLC Unibond Amvvino (NH2)<br />

10 x 10cm, HP-NH2F 150µm 25 722077<br />

HPTLC Unibond Cyano (CN)<br />

10 x 10cm, HP-CNF 150µm 25 723077<br />

Reversed-Phase HPTLC Unibond<br />

10 x 10cm, HP-RP18 150µm 25 762077<br />

10 x 10cm, HP-RP18F 150µm 25 763077<br />

*F-Fluorescent Indicator, 254nm.<br />

Silica Gel G Uniplates<br />

Layer<br />

Thickness<br />

G<br />

Part No.<br />

GF*<br />

Part No.<br />

Description<br />

Qty.<br />

Soft Layer, No Binders<br />

Conventional<br />

20 x 20cm 250µm 25 701011 702011<br />

10 x 20cm 250µm 25 701021 702021<br />

5 x 20cm 250µm 25 701031 702031<br />

Scored, Four 5 x 20cm Sections<br />

20 x 20cm 250µm 25 701511 702511<br />

Preadsorbent<br />

20 x 20cm 250µm 25 731011 732011<br />

Preparative Uniplates, Soft Layer<br />

Conventional Prep<br />

20 x 20cm 500µm 25 701012 702012<br />

20 x 20cm 1000µm 25 701013 702013<br />

20 x 20cm 1500µm 25 701014 702014<br />

20 x 20cm 2000µm 25 701015 702015<br />

Preadsorbent Prep Silica Gel G<br />

20 x 20cm 500µm 25 731012 732012<br />

20 x 20cm 1000µm 25 731013 732013<br />

Hard Layer, Inorganic Binder<br />

Conventional<br />

20 x 20cm 250µm 25 711011 721011<br />

10 x 20cm 250µm 25 711021 721021<br />

Scored, Four 5 x 20cm Sections<br />

20 x 20cm 250µm 25 711511 721511<br />

*F-Fluorescent Indicator, 254nm.<br />

related products<br />

Looking for a fast and easy way to score .<br />

your own TLC plates?<br />

See our TLC plate cutter on page 196.<br />

3923<br />

tlc<br />

www.discoverysciences.com<br />

193


prep | flash | tlc<br />

TLC Tanks and Storage<br />

Cylindrical TLC Tanks<br />

• Requires minimal solvent usage<br />

• Glass cylindrical tanks with press-on lids<br />

best<br />

seller<br />

Rectangular TLC Tanks<br />

• Unique beveled lip to<br />

eliminate sharp edges<br />

• Uniform flat top for maximum<br />

lid seal<br />

Cylindrical TLC Tanks<br />

Description<br />

Cylindrical TLC Tanks for 5 x 10mm and 4 x 8cm Plates,<br />

2.5" o.d., 5" Height<br />

Cylindrical TLC Tanks for 5 x 20cm Plates, 2.5" o.d.,<br />

9" Height<br />

Cylindrical TLC Tanks for 10 x 20cm Plates, 5" o.d.,<br />

9" Height<br />

Microslide TLC Tank<br />

• Small glass chamber holds up to<br />

10 microslide plates<br />

• Requires minimal solvent usage<br />

Part No.<br />

17108<br />

17107<br />

17002<br />

5341<br />

This Rectangular TLC Tank is<br />

a heavy wall, clear glass block<br />

with flat surface walls. Lids are<br />

polished glass in sizes to match<br />

the tank dimensions.<br />

Rectangular TLC Tanks<br />

Description<br />

Rectangular Tanks, All Supplied with Glass Lid<br />

Thinline Tank for 10 x 10cm Plates,<br />

(12cm x 11.5m x 6.4cm), (4.75" x 4.5" x 2.5")<br />

Standard Tank for 10 x 10cm Plates,<br />

(12cm x 11.5cm x 8.6cm), (4.75" x 4.5" x 3.37")<br />

Standard Tank for 20 x 20cm Plates,<br />

(27cm x 24cm x 7cm), (10.5" x 10" x 3")<br />

Standard Tank for 10 x 20cm Plates,<br />

(27cm x 13cm x 7cm), (10.5" x 5" x 3")<br />

Standard Tank for 5 x 5cm Plates,<br />

(17cm x 15cm x 8cm), (7" x 6" x 3")<br />

Part No.<br />

7581<br />

7550<br />

7645<br />

7582<br />

7580<br />

5346<br />

tlc<br />

Microslide TLC Tank<br />

Description<br />

Part No.<br />

Microslide Tank 30020<br />

5342<br />

TLC Tank Pads<br />

• Medium weight lint-free pads for<br />

TLC tank liners<br />

Latch-Lid TLC Chromatotank<br />

• Unique latching device assures tight<br />

seal between lid and tank<br />

• No messy “grease” seals<br />

The unique latching device holds the<br />

matching ground glass surfaces of the<br />

lid and tank firmly in place to maintain an<br />

optimal equilibration atmosphere. The metal components<br />

of the Latch-Lid mechanism are made of stainless steel.<br />

Latch-Lid Chromatotank<br />

Description<br />

Part No.<br />

Standard Latch-Lid Tank/Lid Unit, 10 x 10cm Plates 7542<br />

Latch-Lid Tank/Lid Unit, 20 x 20cm Plates 7536<br />

5350<br />

TLC Pads<br />

Description<br />

Part No.<br />

20 x 20cm, Medium Weight, 100/pk 7630<br />

tech tip<br />

Rectangular TLC Tank Dimensions<br />

• All are inside dimensions<br />

• Listed as height x width x depth<br />

D<br />

H<br />

W<br />

5345<br />

0571<br />

Multiple Plate Development Rack<br />

• Saves time and money<br />

• Choice of anodized aluminum or PTFE<br />

resin-coated rack<br />

• Sizes available to hold six 20 x 20cm or<br />

six 10 x 10cm plates<br />

related products<br />

Need a timer?<br />

See page 265.<br />

6563<br />

5349<br />

Multiple Plate Development Rack<br />

Description<br />

Part No.<br />

Anodized Aluminum Rack for 20 x 20cm Plates 17051<br />

Anodized Aluminum Rack for 10 x 10cm Plates 17053<br />

PTFE-Coated Rack for 20 x 20cm Plates 17074<br />

PTFE-Coated Rack for 10 x 10cm Plates 17077<br />

194 www.discoverysciences.com


prep | flash | tlc<br />

Sprayers<br />

Compressed Gas Sprayer<br />

• Replaceable pressure unit<br />

• Refillable sprayer<br />

• Reusable glass or plastic<br />

container<br />

Compressed Gas Sprayers<br />

provide a constant pressure and<br />

uniform distribution of fine mist<br />

on your TLC plate. The pressure<br />

unit contains difluoroethane.<br />

Unit sprays up to 16oz of liquid.<br />

Caution: Wetted parts are made<br />

of polypropylene or nylon. Do not<br />

store with dip tube immersed in reagent.<br />

Safety Top Screw Cap Sprayer<br />

• Made of borosilicate glass<br />

• Autoclavable<br />

Safety Top Sprayers adjust<br />

the mist by covering the rear<br />

vent hole with a thumb. The<br />

atomizer tops are attached to<br />

the reservoir flasks with a screw<br />

top and o-ring. The screw top<br />

delivers a positive seal between<br />

sprayer head and reservoir,<br />

eliminating the possibility<br />

of “blow back”. Remove the<br />

screw cap and o-ring prior to<br />

autoclaving. Operation of the<br />

unit is by low air pressure (5lb).<br />

best<br />

seller<br />

Compressed Gas Sprayer<br />

Description Qty. Part No.<br />

Complete Spray Unit with Glass Jar 3 14654<br />

Replacement Glass Jar with Lid 6 14655<br />

Disposable Poly Jar with Lid 6 14656<br />

Replacement Compressed Gas Unit 6 14657<br />

5329<br />

5332<br />

Atomizer Sprayer<br />

• Atomizer bulb or<br />

compressed gas<br />

propellant source<br />

This borosilicate glass<br />

sprayer has a rear vent hole<br />

that allows full control of<br />

mist. It has a 4oz (125mL)<br />

reservoir. It is suitable for use<br />

with most corrosive liquids.<br />

Atomizer Reagent Sprayer<br />

Description Qty. Part No.<br />

Atomizer Reagent Sprayer ea 17017<br />

Spraying Accessories<br />

Disposable Spray Box<br />

• Opens easily into 14"L x 14"W x 14"H<br />

(35.56cm) unit<br />

• Unique design for spill containment<br />

• Heavy duty cardboard with disposal<br />

bag provided<br />

Stainless Steel Spray Support<br />

• Self-draining<br />

• Holds plate above the<br />

spraying surface<br />

5331<br />

5367<br />

5369 5407<br />

tlc<br />

Safety Top Sprayer with Screw Cap<br />

Description Qty. Part No.<br />

10mL ea 14540<br />

50mL ea 14545<br />

125mL ea 14550<br />

250mL ea 14555<br />

Polypropylene Spray Stand<br />

• Front edge to hold plate for spraying<br />

• Ideal for use in fume hood<br />

TLC Spray Supports<br />

Description Qty. Part No.<br />

Disposable Spray Box 5 16408<br />

Stainless Steel Spray Support ea 16409<br />

Polypropylene Spray Stand ea 7636<br />

5370<br />

www.discoverysciences.com<br />

195


prep | flash | tlc<br />

TLC Accessories<br />

TLC Plate Cutter<br />

• Scores coated glass plates at<br />

any position<br />

• Compact, portable, and easy<br />

to operate<br />

The TLC Plate Cutter has a highquality<br />

carbide scriber mounted<br />

into a movable plastic head. It is designed to produce optimal<br />

scoring on the glass surface of 20 x 20cm TLC plates with a<br />

total thickness (glass + coating) of 2mm. A smaller template<br />

is included with the unit for ease in cutting 10 x 10cm plates.<br />

3923<br />

TLC Spotting Guide<br />

This template fits over a standard 20 x 20cm<br />

TLC plate. 1cm divisions allow for accurate<br />

sample application. After development,<br />

a series of labelled circles and lines on<br />

the template helps to estimate areas or<br />

to measure distances for Rƒ calculations.<br />

best<br />

seller<br />

Spotting Accessories<br />

Description Qty. Part No.<br />

TLC Spotting Guide ea 7624<br />

4128<br />

tlc<br />

TLC Plate Cutter<br />

Description Qty. Part No.<br />

TLC Plate Cutter ea 7535<br />

Replacement Scribers 1 7565<br />

3 7575<br />

tech tip<br />

Note About Sample Applications<br />

Thorough drying of samples is a step that is often ignored but can<br />

result in development errors. If a small amount of solute is left on<br />

the plate it can interact with the development system and affect<br />

the separation.<br />

Many analysts assume the plate is dry when the solvent is no<br />

longer visible on the plate (5–10 minutes). However, depending<br />

on the volatility of the solvent and the quantity of sample applied,<br />

the drying time can be considerably longer. Generally, Rƒ values<br />

decrease as drying time increases until the dry state (stable Rƒ)<br />

is reached.<br />

Plates can absorb moisture from the atmosphere during storage,<br />

so prior to sample application, all TLC plates should be heated<br />

at 120–130°C for about 30–40 minutes and allowed to cool in<br />

a desiccator. This ensures reproducible Rƒ values.<br />

Universal Spotting Template<br />

• Use to cut channels or to spot plates<br />

• Measure Rƒ values<br />

• Non-slip surface works with any size<br />

TLC plates<br />

Spotting Accessories<br />

Description Qty. Part No.<br />

Universal Spotting Template ea 26270<br />

TLC Plate Coating Supplies<br />

• Desaga plate coating device<br />

and template<br />

• Adsorbosil ® -Plus powders and<br />

polished glass plates<br />

Plate Coating Supplies<br />

Description Qty. Part No.<br />

Desaga Plate Spreading Device and Template<br />

Plate Spreading Device ea 95116<br />

Plate Spreading Template ea 95118<br />

Polished Glass Plates<br />

20 x 20cm Plate, 3mm Thick 10 26080<br />

Alltech ® Adsorbosil ® Powders<br />

Adsorbosil ® -Plus 1 1lb 160201<br />

Macherey-Nagel Powders<br />

Cellulose MN 301 1000g 81605<br />

4130<br />

5384<br />

TLC Plate Scriber<br />

• Cuts channels in soft and hard layers<br />

• Adjust channel widths in multiples<br />

of 1cm<br />

• Made of flexible stainless steel<br />

Spotting Accessories<br />

Description Qty. Part No.<br />

TLC Plate Scriber ea 17102<br />

4132<br />

196 www.discoverysciences.com


prep | flash | tlc<br />

TLC Accessories<br />

Sample Applicators<br />

Drummond ® Microcaps<br />

• Accuracy of ±1%<br />

The Drummond ® Microcap is a<br />

precision bore glass capillary tube<br />

that holds a known volume when<br />

filled by capillary action. The tube is<br />

emptied completely by squeezing<br />

the dispenser bulb. (Bulb is included with the unit.)<br />

Drummond ® Sample Applicators<br />

Description/Capacity Qty. Part No.<br />

Drummond ® Microcaps<br />

0.5µL 100 3808<br />

1.0µL 100 3809<br />

2.0µL 100 3810<br />

3.0µL 100 3811<br />

5.0µL 100 3814<br />

10.0µL 100 3820<br />

15.0µL 100 3821<br />

20.0µL 100 3822<br />

25.0µL 100 3823<br />

50.0µL 100 3828<br />

100.0µL 100 3838<br />

Drummond ® Microcap Accessories<br />

Microcap Bulbs 6 3940<br />

5338<br />

Drummond ® Wiretrol ® Micropipettes<br />

• Combines the accuracy of a<br />

microsyringe with the ease and<br />

economy of a disposable pipette<br />

• Accuracy of ±1%<br />

• Color-coded with a permanent<br />

calibration line<br />

These unique pipetting devices<br />

feature one-handed operation.<br />

Each unit contains a vial of 100<br />

micropipettes, dispenser cap, handle,<br />

and one stainless steel plunger.<br />

Drummond ® Sample Applicators<br />

Description/Capacity Qty. Part No.<br />

Drummond ® Wiretrol ® Micropipettes<br />

1.0 to 5.0µL (Calibrated) 100 3842<br />

3.0µL 100 3843<br />

5.0µL 100 3844<br />

10.0µL 100 3845<br />

20.0µL 100 3846<br />

25.0µL 100 3847<br />

50.0µL 100 3849<br />

100.0µL 100 3851<br />

5286<br />

Uncalibrated Disposable Micropipettes<br />

Uncalibrated disposable glass<br />

micropipettes are intended for rapid<br />

qualitative sample application on<br />

TLC plates. Thick walls make these<br />

pipettes strong and easy to handle.<br />

Overall length is about three inches.<br />

Capacity is approximately 2–8µL.<br />

Uncalibrated Disposable Micropipettes<br />

Description Qty. Part No.<br />

Glass Micropipettes 300 7616<br />

1440 17203<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

Syringes for Thin Layer Chromatography<br />

• PTFE-coated needle tip (3/4")<br />

• Standard 2" needle length<br />

5340 5283<br />

TLC Syringes<br />

Description/Capacity Qty. Part No.<br />

TLC Syringes with PTFE-Coated Needles<br />

Fixed Needle, Blunt Point<br />

10µL, 26s ga. ea 800500<br />

25µL, 22s ga. ea 802500<br />

50µL, 22 ga. ea 80950<br />

100µL, 22 ga. ea 81050<br />

tlc<br />

www.discoverysciences.com<br />

197


prep | flash | tlc<br />

TLC Accessories<br />

UV Viewing Cabinet<br />

• Fixed eyepiece with UV<br />

shielded window<br />

• Uses 4- and 6-watt E-series<br />

lamps<br />

TLC Sample Recovery Tubes<br />

• Removes samples from TLC<br />

plates by suction<br />

• Reusable, all glass<br />

construction<br />

The UV Viewing Cabinet measures<br />

6.5" H x 9" W x 12" L (16.5cm H x<br />

22.9cm W x 30.5cm L). This cabinet<br />

cannot be used for photo systems<br />

because of the fixed eyepiece.<br />

UV Viewing Cabinet, Supplied Without Lamps<br />

Description<br />

Part No.<br />

UV Viewing Cabinet, Model CM-10 80305<br />

5352<br />

Connect a vacuum to one end of<br />

the sample recovery tube and pull the sample into the<br />

tube. Then pass solvent through the recovery tube to extract<br />

the sample.<br />

TLC Sample Recovery Tubes<br />

Description Qty. Part No.<br />

0.5–1mL Sample Recovery Tube ea 17010<br />

1–2mL Sample Recovery Tube ea 17011<br />

25–30mL Sample Recovery Tube ea 17012<br />

5288<br />

tlc<br />

E-Series Ultraviolet Lamps<br />

• Easy to operate<br />

• Choice of intensity, wavelengths,<br />

and sizes<br />

The Spectroline ® E-Series Lamps can be<br />

used as portable units, with UV viewing<br />

cabinets, or in photo darkroom cabinets.<br />

Lamps with a filter assembly provide<br />

maximum fluorescent contrast with the<br />

least white light transmission.<br />

E-Series Lamps<br />

Description<br />

Part No.<br />

8-Watt Combo Lamp<br />

LW, SW, and Filter Assembly, 115V 80240<br />

LW, SW, and Filter Assembly, 230V 80245<br />

8-Watt Replacement Parts<br />

LW Replacement Tube 80242<br />

SW Replacement Tube 80244<br />

Combo Light Replacement Filter 80246<br />

6-Watt Combo Lamp<br />

LW, SW, and Filter Assembly, 115V 80250<br />

LW, SW, and Filter Assembly, 230V 80255<br />

6-Watt Replacement Parts<br />

LW Tube Replacement 80252<br />

SW Tube Replacement 80254<br />

Combo Light Filter Replacement 80256<br />

4-Watt Combo Lamp<br />

LW, SW, and Filter Assembly, 115V 80270<br />

LW, SW, and Filter Assembly, 230V 80275<br />

4-Watt Replacement Parts<br />

LW Tube Replacement 80272<br />

SW Tube Replacement 80274<br />

Combo Light Filter Replacement 80276<br />

Lamp Accessories<br />

UV Lamp Stand 80218<br />

UV Lamp Handle (not shown) 80219<br />

5353<br />

pH-Fix Universal Indicator Sticks<br />

• Four indicator papers<br />

(6 x 5mm) are sealed to each<br />

6 x 85mm stick<br />

pH-Fix Universal Indicator Sticks<br />

Description Qty. Part No.<br />

Range 0–14, 1.0pH Units 100 18147<br />

Range 4.5–10, 0.5pH Units 100 18158<br />

Range 7.0–14, 0.5pH Units 100 18160<br />

Adsorbent Scraper<br />

• Blade mounted in “easy-grip” handle<br />

13mm—Scrape Large Areas<br />

6mm—Small Spots, Ideal for Radial Chromatography and .<br />

Linear HPTLC<br />

2mm—Score Lines, Channels, and Scrape Small Spots<br />

TLC Scrapers<br />

Description Qty. Part No.<br />

TLC Scraper Kit: 1 of each type Kit 7626<br />

13mm TLC Scraper ea 7627<br />

Replacement Blades, 13mm 10 7627B<br />

6mm TLC Scraper ea 7602<br />

Replacement Blades, 6mm 5 7602B<br />

2mm TLC Scraper ea 7600<br />

Replacement Blades, 2mm 5 7600B<br />

0614<br />

5366<br />

198 www.discoverysciences.com


GC<br />

GC Instruments. . . . . . . . . . . . . . . . . 200–212<br />

GC Systems & Data Collection . . . . . . . . . . . 200–205<br />

Gas Generators<br />

Hydrogen. . . . . . . . . . . . . . . . . . . . . . . . . 206–207<br />

Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208–209<br />

Nitrogen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />

Air Compressors . . . . . . . . . . . . . . . . . . . . 211–212<br />

GC Columns. . . . . . . . . . . . . . . . . . 213–258<br />

Introduction. . . . . . . . . . . . . . . . . . . . . . 213–214<br />

Alltech ® Capillary Columns. . . . . . . . . . . . . . 215–234<br />

Custom Columns . . . . . . . . . . . . . . . . . . . . . . . 215<br />

Alltech ® Heliflex ® and Alltech ® Econo-Cap . . . . . . 216–231<br />

EPA Methods Guide. . . . . . . . . . . . . . . . . . . 232–234<br />

Distributed Capillary Columns . . . . . . . . . . . . 235–238<br />

Astec . . . . . . . . . . . . . . . . . . . . . . . . . . 235–236<br />

SGE ® . . . . . . . . . . . . . . . . . . . . . . . . . . . 237–238<br />

Alltech ® Packed Columns . . . . . . . . . . . . . . 239–258<br />

Custom Packed . . . . . . . . . . . . . . . . . . . . . 239–243<br />

Popular Packed . . . . . . . . . . . . . . . . . . . . . 244–245<br />

CTR Concentric Packed Columns . . . . . . . . . . . . . 246<br />

Pretested Packings . . . . . . . . . . . . . . . . . . . 247–248<br />

Custom Coated Packings . . . . . . . . . . . . . . . 249–250<br />

GC Supports and Packings . . . . . . . . . . . . . . 251–258<br />

GC Accessories . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .259–294<br />

Capillary Accessories . . . . . . . . . . . . . . . . 259–261<br />

Packing Accessories . . . . . . . . . . . . . . . . . 262–263<br />

Gas Flow and Detection . . . . . . . . . . . . . . . 264–267<br />

Gas Purification . . . . . . . . . . . . . . . . . . . 268–275<br />

Gas Sampling . . . . . . . . . . . . . . . . . . . . 276–279<br />

Ferrules. . . . . . . . . . . . . . . . . . . . . . . . 280–281<br />

Fittings . . . . . . . . . . . . . . . . . . . . . . . . 282–285<br />

Injection Liners & Accessories . . . . . . . . . . . . 286–288<br />

Septa . . . . . . . . . . . . . . . . . . . . . . . . . 289–292<br />

Valves . . . . . . . . . . . . . . . . . . . . . . . . 293–294


gas chromatography<br />

SRI Gas Chromatographs<br />

• Value-priced — Typically half the price of comparable<br />

units from other manufacturers<br />

• Versatile — Choose from a large selection of GC<br />

detectors and injectors<br />

• PC Programmable — PeakSimple data control<br />

software included<br />

Choose from Two Chassis:<br />

Model 8610C<br />

– for performance and maximum flexibility<br />

Model 310<br />

– for economy and compact size<br />

BioDiesel GC System<br />

SRI BioDiesel GC Systems are configured to perform ASTM<br />

6584. Analysis takes about 25 minutes and is simple enough<br />

to run in the field.<br />

Systems Include:<br />

• Choice of 8610C or 310 chassis<br />

• FID detector<br />

• On-column injector<br />

• 15-meter wide-bore capillary column<br />

• PeakSimple software<br />

gc instruments<br />

2342 3893<br />

Model 8610C Model 310<br />

SRI GC Specifications<br />

SRI GC Model: 8610C 310<br />

Temperature: Ambient to 400ºC Ambient to 400ºC<br />

Programmable: Yes, Multiple Steps Yes, Multiple Steps<br />

Oven Inches: 3" H x 7.5" W x 7.5" D 3" H x 5" W x 5" D<br />

Oven Metric: 7.6cm x 19.1cm x 19.1cm 7.6cm x 12.7cm x 12.7cm<br />

Capillary Column: 7" Cage Capillaries 4" Cage Capillaries<br />

Packed Column: 1/4" or 1/8" 1/8"<br />

Detectors: Up to 4 Up to 4<br />

Inlets: On-Column, Up To 5 On-Column, 1 inlet<br />

Dimensions Inches: 13" H x 18.5" W x 14.5" D 13" H x 12.5" W x 14.5" D<br />

Dimensions Metric: 33cm x 47cm x 36.8cm 33cm x 31.7cm x 36.8cm<br />

Weight: 45–80lb (20–36kg) 40–70lb (18–32kg)<br />

more info<br />

SRI Systems are CE, TUV, GS, and NRTL approved. SRI<br />

manufactures all instruments in compliance with EN 61010<br />

standards for laboratory equipment. Instruments come with<br />

a two-year warranty.<br />

BioDiesel GC Systems<br />

7380<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

BioDiesel Analyzer on 8610C Chassis 8618932 8618933<br />

BioDiesel Analyzer on 310 Chassis 8618934 8618935<br />

Every SRI GC Comes Complete with:<br />

• Single on-column injector for 0.53mm i.d. capillary or<br />

1/8" packed columns or injectors of choice<br />

• Electronic pressure control for all gases<br />

• Temperature programmable oven—programmable in<br />

multiple segments<br />

• Digital pressure readout<br />

• Digital temperature readout—ambient to 400°C<br />

• Built-in data system with PeakSimple for Windows ®<br />

software<br />

• Operator’s manual<br />

• 10μL syringe and spare septa<br />

• Heavy-duty reusable shipping container. Shipped<br />

easily by common carriers (UPS or FedEx)<br />

7381<br />

related products<br />

Looking for more biodiesel analysis solutions?<br />

Visit www.gracebiofuels.com.<br />

200 www.discoverysciences.com


gas chromatography<br />

Preconfigured SRI GCs<br />

Enjoy the Convenience of Ordering a System<br />

Already Optimized for Your Application<br />

Preconfigured GCs are designed with inlet systems,<br />

detectors, and accessories required for a specific application.<br />

The preconfigured GCs are also supplied with an internal data<br />

acquisition system and PeakSimple for Windows ® software<br />

to control the GC and acquire and analyze the data.<br />

Educational GC – 310 Chassis<br />

Gasless with CCD (built-in air compressor)<br />

• Standard on-column injector<br />

• Detects combustible (hydrocarbon) molecules<br />

• Packed GC column included<br />

Multiple Gas Analyzer—8610C Chassis<br />

Separates H2, O2, N2, CH4, CO2, and Hydrocarbons.<br />

Model 1—Fixed Gases and C1 to C6 Hydrocarbons<br />

• Two columns—MoleSieve 13x and silica gel<br />

• Sensitivity for CO and CO2 to ppm level<br />

• 10-port gas sampling automatic valve and loop<br />

Model 1—Multiple Gas Analyzer<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

Model 1 with TCD Single Channel 8610022 8610512<br />

Model 1 with TCD/FID* 8610023 8610513<br />

Model 1 with TCD/HID* 8610501 8610514<br />

*Four-channel PeakSimple data system.<br />

Model 310 with CCD<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

Gasless with CCD with cooling 31001105 310502<br />

Gasless with CCD without cooling 8611252 8611305<br />

TCD System (fast and manual cool down)<br />

• Universal detector sensitive from 100% to 200ppm<br />

• Can analyze room air, human breath<br />

• Packed GC column included<br />

Model 310 with TCD<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Model 310 with TCD 8610001 310501<br />

Models 1 and 2 Plus Sulfur<br />

Multiple gas and sulfur analysis in one unit. Detects low sulfur<br />

concentrations.<br />

• TCD, FID-methanizer and FPD/FID detectors<br />

• Uses just one gas sampling valve with Silcosteel ®<br />

• 2-meter MoleSieve and silica gel columns<br />

• 60-meter capillary column<br />

• Built-in air compressor<br />

• Four-channel PeakSimple data system<br />

Models 1 and 2 Plus Sulfur—Multiple Gas Analyzer<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Model 1 Plus Sulfur 8611271 8611325<br />

Model 2 Plus Sulfur 8611274 8611307<br />

gc instruments<br />

FID System<br />

• Carrier and combustion gas<br />

• Packed GC column included<br />

Model 310 with FID<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Model 310 FID with cooling 8611251 8611306<br />

Basic Capillary FID GC—8610C Chassis<br />

• Hydrocarbon selective from 100% to 1ppm<br />

• Built-in air compressor<br />

• 30-meter x 0.53mm capillary column included<br />

Basic Capillary FID GC<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Basic Capillary FID GC 8610523 8610524<br />

Model 2 Fixed Gases and C1 to C20 Hydrocarbons<br />

• Heated 10-port gas sampling valve (electrically actuated)<br />

• Column switching<br />

• Also measures water and alcohol<br />

• Two packed GC columns<br />

Model 2—Multiple Gas Analyzer<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

Model 2 with TCD 8610503 8612232<br />

Model 2 with TCD/FID/Methanizer 8610504 8612233<br />

Model 2 with TCD/HID 8611273 8610514<br />

Sulfur GC—8610C Chassis<br />

For the analysis of H2S in natural gas, total reduced sulfur<br />

analysis, mercaptans, and sulfur containing pesticides.<br />

• FID/FPD combination detector<br />

• Built-in air compressor<br />

• 1-meter PTFE Hayesep ® D column<br />

• 10-port gas sampling valve with nickel loop<br />

• Four-channel PeakSimple data system<br />

Sulfur GC<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Sulfur GC 8610525 8610517<br />

www.discoverysciences.com<br />

201


gas chromatography<br />

gc instruments<br />

Preconfigured SRI GCs<br />

BTU Gas Analyzer—8610C Chassis<br />

For the analysis of natural gas and computing the BTU rating.<br />

Measures nitrogen, methane, carbon dioxide, ethane, water,<br />

propane, iso and normal butanes, iso and normal pentanes,<br />

and C6 plus hydrocarbons.<br />

• Thermal conductivity detector<br />

• 10-port gas sampling valve<br />

• Packed GC column<br />

• 30 meter capillary column<br />

BTU Gas Analyzer<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

BTU Gas Analyzer 86103070 8610518<br />

Environmental GC—8610C Chassis<br />

Ideal for laboratory or field-testing applications where space,<br />

price, and versatility are crucial. The Environmental GC is<br />

designed for EPA methods 5030, 5030/5035. It will easily<br />

generate certification quality data for EPA Methods 8021,<br />

8010, 8015, TO-14, and many others.<br />

• FID, PID, and DELCD detectors<br />

• Equipped with the method 5030/5035 compliant purge<br />

and trap<br />

• Built-in air compressor<br />

• 60 meter capillary column<br />

• Four-channel PeakSimple data system<br />

Environmental GC<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Environmental GC 8610058 8612258<br />

PCB GC—8610C Chassis<br />

Detects PCBs in soil and other solids. Also used for analysis<br />

of pesticides, PAHs, JP-4, kerosene, and diesel. Accepts<br />

1-gram samples.<br />

• FID/DELCD combination detector<br />

• Built-in thermal desorber<br />

• Built-in air compressor<br />

• Four-channel PeakSimple data system<br />

PCB GC<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

PCB GC 8611265 8611308<br />

BTEX GC—8610C Chassis with FID/PID<br />

Designed for the analysis of benzene, toluene, ethylbenzene,<br />

and xylenes.<br />

• Method 5030/5035 compliant purge and trap<br />

• Built-in air compressor<br />

• 60 meter capillary column<br />

• Four-channel PeakSimple data system<br />

BTEX GC<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

BTEX GC 8612250 8610510<br />

5030/5035 Compliant Upgrade 8611267 8611309<br />

TO-14 GC—8610C Chassis<br />

Designed for the TO-14 or an ambient air analysis.<br />

• PID and FID/DELCD detectors<br />

• Dual trap sample concentrator<br />

• Built-in air compressor<br />

• Vacuum pump interface<br />

• 60 meter capillary column<br />

• Four-channel PeakSimple data system<br />

TO-14 GC<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

TO-14 GC 8610502 8610515<br />

Mud-Logging GC—8610C Chassis<br />

Reports the total hydrocarbons of a gas stream as well as<br />

performing separations.<br />

• Flame ionization and catalytic combustion detector<br />

• Packed GC column<br />

• Built-in air compressor<br />

• 10-port gas sampling valve<br />

• Four-channel PeakSimple data system<br />

Mud-Logging GC<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Mud-Logging GC 8610500 8610511<br />

TOGA GC System—8610C Chassis<br />

This portable unit determines the gases dissolved in<br />

transformer oil.<br />

• HID and/or TCD detectors<br />

• MoleSieve and silica gel-packed columns<br />

• Syringe pump for industry standard 50mL syringes<br />

• Dual 10-port gas sampling valves<br />

• Gas extraction loop<br />

TOGA GC System<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

TOGA with TCD Detector 8611326 8611327<br />

TOGA with HID Detector 8611328 8611329<br />

TOGA with TCD and HID Detector 8611330 8611331<br />

202 www.discoverysciences.com


gas chromatography<br />

SRI Accessories<br />

Method 5035 Compliant Purge and Trap<br />

Ideal for higher level soil samples or<br />

soil/methanol extractions. Uses low<br />

cost disposable 16mm test tubes which<br />

are purged at ambient temperature.<br />

Method 5035 Compliant Purge and Trap<br />

Description<br />

Part No.<br />

Method 5035 Compliant Purge and Trap 8690051<br />

Upgrade Purge and Trap 5030/5035 Compliant 8611302<br />

SRI 10-Port Gas Sampling Valve<br />

Factory plumbed and tested according to your application.<br />

Can only be mounted on the 8610C GC.<br />

SRI 10-Port Gas Sampling Valve<br />

Description<br />

Part No.<br />

10-Port Gas Sampling Valve—Manual 8690063<br />

10-Port Gas Sampling Valve—Electric 8690065<br />

Thermostatted Valve Oven<br />

Can only be mounted on the Model 8610C GC.<br />

Accommodates one or two electronically actuated and one<br />

manually actuated valve. The oven can be heated to 175°C<br />

for electrically actuated valves and autosamplers.<br />

6685<br />

Custom SRI Systems<br />

Follow these basic instructions to configure your custom GC.<br />

On either chassis, you can order as many as four detectors.<br />

On the Model 310 chassis, you are limited to one sample inlet<br />

system; on the Model 8610C you may order as many as five.<br />

If you need a gas sampling valve, you must order a Model<br />

8610C. If you have any questions, contact our Technical<br />

Support group.<br />

How to Build a Custom GC:<br />

1. Choose a chassis with the appropriate channels.<br />

(page 203)<br />

2. Choose inlet system; as many as five for 8610C,<br />

one for 310. (page 204)<br />

3. Choose up to four detectors. (page 204)<br />

SRI Chassis<br />

Model 310 Chassis<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

With 1-Channel PeakSimple 8611249 8611250<br />

With 4-Channel PeakSimple 3100100 3100122<br />

With 6-Channel PeakSimple 8611257 8611258<br />

3893<br />

gc instruments<br />

Thermostatted Valve Oven<br />

Description<br />

Part No.<br />

Thermostatted Valve Oven 8690088<br />

Model 311H 42 Vial Liquid Autosampler<br />

Injection volume is adjustable from 0–3µL.<br />

Requires 1mL of sample and an inert gas<br />

source at 60psig to operate. One hundred<br />

screw cap vials and septa are included.<br />

Model 8610C Chassis<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

With 1-Channel PeakSimple 8611275 8611276<br />

With 4-Channel PeakSimple 8610102 8612202<br />

With 6-Channel PeakSimple 8611285 8611286<br />

2342<br />

Model 311H 42 Vial Liquid Autosampler<br />

Description<br />

Part No.<br />

Model 311H 42 Vial Liquid Autosampler 8690068<br />

7399<br />

www.discoverysciences.com<br />

203


gas chromatography<br />

gc instruments<br />

SRI Inlet Systems<br />

Every SRI GC is equipped with an unheated on-column inlet<br />

system. On a Model 310 chassis, you can replace that with<br />

any one of the other four inlet systems available—headspace,<br />

split/splitless, purge and trap, and flash. On a Model 8610C<br />

chassis, you can mount any of the inlet systems to a total<br />

of five.<br />

On-Column Inlet Systems<br />

Suitable for 0.53mm capillary and 1/8" packed columns.<br />

Includes EPC carrier gas controller and molecular sieve filter.<br />

On-Column Inlet Systems<br />

Description<br />

Part No.<br />

Additional On-Column Injector 8690023<br />

Heated Static Headspace Inlet System<br />

Ideal for the analysis of volatiles, especially where the sample<br />

matrix is dirty. Sample is heated and injected via a sample<br />

loop and gas sampling valve. Vial sleeve can be heated to<br />

90°C. Requires 10–20mL of sample for operation.<br />

Heated Static Headspace Inlet Systems<br />

Description<br />

Part No.<br />

Heated Static Headspace Injector 8690045<br />

SRI Detectors<br />

The SRI GC allows you to choose the detector(s) you want<br />

installed. The chassis can accommodate as many as four<br />

detectors to give you maximum flexibility.<br />

Table 1 – Detector Specifications<br />

Detector Selectivity Sensitivity (Approx.)<br />

CCD Hydrogen and hydrocarbons 500ppm<br />

TCD Universal 200-500ppm<br />

FID Hydrocarbons 1ppm<br />

DELCD Chlorinated and brominated 10ppb<br />

molecules<br />

FID/DELCD Hydrocarbons, chlorinated and 10ppm<br />

brominated molecules<br />

HID Universal with exception of neon 10ppm<br />

PID<br />

Aromatics and molecules with double 10ppb<br />

carbon bonds<br />

NPD Nitrogen and phosphorus 10ppm<br />

NPD/DELCD Nitrogen, phosphorus, chlorinated 100ppb<br />

and brominated<br />

TID Nitro functional groups (TNT etc.) 1ppb, 50ppb<br />

ECD Electronegative compounds 10ppb<br />

RGD Reducing gases (such as H2 and CO) 10ppb<br />

FPD Sulfur and phosphorus 200ppb and 10ppb<br />

FPD/FID Sulfur, phosphorus, and<br />

hydrocarbons<br />

200ppb, 10ppb, and<br />

100ppm<br />

Dual FPD Sulfur and phosphorus<br />

simultaneously<br />

200ppb and 10ppb<br />

FID Dual FPD<br />

Hydrocarbons, sulfur, phosphorus<br />

simultaneously<br />

100ppm, 200ppb,<br />

and 10ppb<br />

Heated Split/Splitless Injector<br />

Permits the use of narrow-bore capillary columns (0.32mm i.d.<br />

and smaller) in either split or splitless modes. Allows 0.53mm<br />

capillary columns and 1/8" packed columns to be used in<br />

split, splitless or on-column modes. Injector temperature is<br />

adjustable or programmable to 300°C.<br />

Heated Split/Splitless Injector<br />

Description<br />

Part No.<br />

Heated Split/Splitless Injector 8690034<br />

Heated Split/Splitless Injector with PTV 8611303<br />

Heated Flash Vaporization Injector<br />

Vaporizes the sample prior to the column. Ideal for desorption<br />

of SPME fibers or injection of extremely dirty samples. The<br />

injector heater block can be heated to 300°C.<br />

Heated Flash Vaporization Injector<br />

Description<br />

Part No.<br />

Heated Flash Vaporization Injector 8690025<br />

SRI GC Detectors (choose up to four per chassis)<br />

Description<br />

Part No.<br />

CCD (Catalytic Combustion Detector) 86902007<br />

TCD (Thermal Conductivity) 8690107<br />

FID (Flame Ionization) 8690010<br />

DELCD (Dry Electrolytic Conductivity) 86901026<br />

FID/DELCD Simultaneous 8692026<br />

HID (Helium Ionization Detector) 8690030<br />

PID (Photo-Ionization) 8690040<br />

NPD (Nitrogen-Phosphorus) 8690015<br />

NPD/DELCD (Series Detector) 8611299<br />

TID (Thermionic Ionization Detector) 8690017<br />

ECD (Electron Capture) 8690020<br />

RGD (Reduction Gas Detector) 8611293<br />

FPD (Flame Photometric) 8690080<br />

FPD/FID Simultaneous 8691080<br />

DFPD (Dual Flame Photometric) 8690085<br />

related products<br />

Need septa?<br />

See pages 289–292.<br />

204 www.discoverysciences.com


gas chromatography<br />

PeakSimple for Windows ®<br />

• Included with every SRI gas chromatograph<br />

• Runs on Windows ® 95/98/Me or<br />

Windows ® NT/2000/XP<br />

• Interfaces through available serial port or USB<br />

PeakSimple software is simple, fast, and powerful.<br />

Each SRI GC comes with a built in data system and the<br />

PeakSimple software is the interface between your GC<br />

and PC. The PeakSimple software will run on any PC with<br />

a Windows ® 95/98/Me or Windows ® NT/2000/XP operating<br />

system. The software communicates to the GC through an<br />

available serial port or USB.<br />

Features:<br />

• Unlimited temperature and event entries—user defined<br />

temperature and event programs have no size or entry<br />

limitations, allowing a “fine-tune” for each run.<br />

• Multiple point calibration curves—permits exact<br />

quantification of sample components in analysis reports.<br />

• Manual and automated integration correction—<br />

manipulate baseline and integration during and after run.<br />

• Peak grouping—for PCB’s and TPH analysis.<br />

• ASCII or binary file storage—for export to<br />

spreadsheets, etc.<br />

• Automatic calibration at seven concentration levels<br />

with six curve fitting options including straight line,<br />

multi-line, parabolic, and quadratic. Choice of area<br />

or height calculation for each peak.<br />

• High/Low peak alarms with link to user programs if<br />

alarm levels are exceeded.<br />

• Baseline subtraction, peak smoothing, valley<br />

deconvolution, peak reverse, drift correction.<br />

• Overlay chromatograms for easy visual comparisons.<br />

• Autosampler queues for unattended operation allows<br />

mixed methods, auto-recalibration.<br />

• Batch reprocessing of previously run chromatograms.<br />

gc instruments<br />

PeakSimple for Windows ® gives you the flexibility and power to<br />

meet all your chromatographic needs.<br />

4541<br />

Also Available:<br />

Stand Alone Serial Data System<br />

• Comes with PeakSimple for Windows ® software<br />

• Single-, four-, or six-channel models<br />

6690<br />

Stand Alone Serial Data System<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

With 1-Channel Serial Port 8612010 86001255<br />

With 4-Channel Serial Port 86002055 86022055<br />

With 6-Channel USB 86006055 86006255<br />

related products<br />

Looking for other data systems?<br />

See pages 22 and 23.<br />

PeakSimple provides for seven calibration points and six different<br />

types of calibration; from linear to quadratic.<br />

4542<br />

www.discoverysciences.com<br />

205


gas chromatography<br />

Hydrogen Generators for GC Applications<br />

High-Purity Hydrogen from Parker Balston ®<br />

and Domnick Hunter ®<br />

• Provide a safe, reliable source of hydrogen with purity<br />

to 99.99999+%<br />

• Eliminate the cost and inconvenience of dealing with<br />

hydrogen and helium cylinders<br />

• Promote compliance with OSHA and NPFA guidelines<br />

for indoor hydrogen use<br />

• Includes a wide range of flows to meet your needs<br />

Parker Balston ® and Domnick Hunter ® are now one company<br />

offering exceptional gas generation technologies from a single<br />

source. Both brands offer different technologies and several<br />

flow rates to accommodate either single or multiple GC<br />

applications.<br />

Parker Balston ® .<br />

Hydrogen Generator<br />

7436<br />

Domnick Hunter ® .<br />

Hydrogen Generator<br />

7396<br />

gc instruments<br />

GC instrumentation uses hydrogen as either a fuel gas<br />

(FID, FPD, and NPD) or carrier gas. Each application requires<br />

specific and unique gas purity. Parker Balston ® offers both a<br />

desiccant cartridge caustic-free system for fuel applications<br />

and a palladium-based carrier gas range providing the purest<br />

hydrogen commercially available. Domnick Hunter ® offers a<br />

caustic free, carrier grade generator with a durable, built in<br />

micro-dryer that eliminates the need for regular desiccant<br />

cartridge replacement.<br />

Parker Balston ® Hydrogen Generator Technology<br />

Pressure Gauge<br />

Water/Gas<br />

Separators<br />

Shutoff<br />

Valve<br />

Water<br />

Supply<br />

Scrubbing<br />

and Drying<br />

Hydrogen<br />

Outlet<br />

Pressure<br />

Transducer<br />

Check<br />

Valve<br />

Relief<br />

Port<br />

Drain<br />

Port<br />

Proton Exchange<br />

Membrane Cell<br />

7452<br />

206 www.discoverysciences.com


gas chromatography<br />

Hydrogen Generators for GC Applications<br />

Hydrogen Generators Specifications<br />

Parker Balston<br />

Domnick Hunter<br />

Model H2PEM-100 H2PEM-165 H2PEM-260 H2PEM-510 H2-150 H2-300 20H-MD 40H-MD 60H-MD<br />

Flow (cc/min): 100 165 260 510 150 300 160 250 500<br />

Use: Fuel Gas Fuel and Carrier Fuel and Carrier<br />

Max. Number of FIDs: 2 4 6 12 3 6 4 6 12<br />

Max. Number of Injectors/FIDs: N/A 1 2 1 2 4<br />

Purity: 99.9995% 99.99999% 99.9999%<br />

Water Quality: DI Water NaOH Solution DI Water<br />

Purifier Type: Dessicant Palladium Dessicant<br />

Regenerative Purifier: No No Yes<br />

Maximum Pressure (psig): 100 60 100<br />

Dimensions (h x w x d): 17.1" x 13.5" x 17.9"<br />

(43.5cm x 34.2cm x 45.6cm)<br />

22" x 12" x 13"<br />

(58cm x 30cm x 33cm)<br />

18" x 13.5" x 17.2"<br />

(45.6cm x 13.5cm x 43.7cm)<br />

Weight: 40lb (18kg) 58lb (26kg) 62lb (28kg)<br />

Hydrogen Generators<br />

Description<br />

Part No.<br />

Parker Balston ®<br />

Parker Balston ® H2PEM-100, 110/220V 8619101<br />

Parker Balston ® H2PEM-165, 110/220V 8619102<br />

Parker Balston ® H2PEM-260, 110/220V 8619103<br />

Parker Balston ® H2PEM-510, 110/220V 8619104<br />

Parker Balston ® H2-150, 110V 80109<br />

Parker Balston ® H2-150, 220V 80113<br />

Parker Balston ® H2-300, 110V 80112<br />

Parker Balston ® H2-300, 220V 80115<br />

Domnick Hunter ®<br />

Domnick Hunter ® 20H-MD, 110/220V 8618711<br />

Domnick Hunter ® 40H-MD, 110/220V 8618712<br />

Domnick Hunter ® 60H-MD, 110/220V 8618713<br />

gc instruments<br />

Parker HydroGen Mate ® DI Water System<br />

Economically Provide DI Water to Your<br />

Hydrogen Generator<br />

• Removes organics, phosphates, chlorine, and most<br />

ionizable constituents<br />

• Quick and easy installation<br />

• Easy-fill dispensing nozzle<br />

• No electrical requirements<br />

The Parker HydroGen Mate ® DI Water System provides<br />

high purity deionized water to all types of Parker hydrogen<br />

generators. The system is ready to install and includes<br />

prefiltration, two DI resin exchange cartridges, dispensing<br />

nozzle, and a final filter.<br />

Parker HydroGen Mate ® DI Water System<br />

Description<br />

Part No.<br />

Complete DI Water System 8619043<br />

Maintenance Kit* 8619044<br />

*Includes two replacement cartridges and one replacement final filter.<br />

7437<br />

www.discoverysciences.com<br />

207


gas chromatography<br />

Parker Balston ® FID Gas Station<br />

Hydrogen and Zero Air from a .<br />

Single Generator<br />

• Safer and more convenient than gas cylinders<br />

• Save bench space with a single unit<br />

• Minimal operator attention required<br />

• Quiet operation<br />

The Parker Balston ® FID Gas Station combines Parker’s zero<br />

air and hydrogen generation technologies into a single unit,<br />

eliminating the inconveniences and cost of hydrogen and<br />

gas cylinders. The Model FID-1000 gas station will supply<br />

90cc/min hydrogen and 1000cc/min of zero grade air and<br />

can supply fuel gas for two flame ionization detectors. With<br />

a 250cc/min hydrogen and 2500cc/min zero air generating<br />

capacity, the FID-2500 gas station can supply gases for up<br />

to six flame ionization detectors.<br />

gc instruments<br />

Hydrogen Generation<br />

Hydrogen gas is produced from deionized water using a<br />

Proton exchange membrane cell. The hydrogen supplied<br />

is 99.9995% pure with pressures up to 60psig.<br />

Zero Air Generation<br />

The FID Gas station improves FID baseline stability by<br />

providing zero grade air from an on-site compressed air<br />

source. The FID-1000 produces zero air containing


gas chromatography<br />

Zero Air Generators<br />

Improve your Productivity by Using.<br />

Air Generators Instead of Cylinders<br />

• Replace bulky cylinders that need frequent changing<br />

• Consistently high-purity for high-quality GC results<br />

Gas Chromatography requires zero air or air


gas chromatography<br />

UHP Nitrogen Generators<br />

Ideal for GC and for TOC<br />

Gas Chromatography applications require ultra high purity<br />

nitrogen. With GC, nitrogen may be a carrier gas or makeup<br />

gas but regardless it needs low ppm oxygen, carbon<br />

dioxide, carbon monoxide, and hydrocarbon. These low levels<br />

of impurities are needed to protect the column and some<br />

detectors.<br />

Total Organic Carbon (TOC) analyzers use special purified<br />

nitrogen as a purge gas. It is important that both the air and<br />

nitrogen be hydrocarbon (including Methane), CO2 and CO<br />

free. This allows for the best signal to noise ratio with the TOC<br />

analyzer. The TOC Nitrogen Gas Generator is zero grade<br />

(


gas chromatography<br />

JUN-AIR ® Oil-Less Air Compressors<br />

Standard—B Series<br />

Complete compressed air unit with a<br />

holding tank.<br />

Standard Air Compressors*<br />

Description<br />

Part No.<br />

Model OF302-4B 89299<br />

Model OF302-25B 89279<br />

Model 2000-40B 89319<br />

Model 4000-40B 89272<br />

*Must specify voltage when ordering. Choose from 120V/60Hz, 240/60Hz, or<br />

230V/50Hz. Two-year manufacturer’s warranty.<br />

Standard Plus Air Dryer—D Series<br />

The D series is equipped with filters that<br />

have manual and automatic drains and an<br />

adsorption dryer to ensure 100% clean,<br />

dry, and oil-free air.<br />

Air Compressors with Dryer Option*<br />

Description<br />

Part No.<br />

Model OF302-4BD2 89376<br />

Model OF302-25BD2 89239<br />

Model 2000-40BD2 89328<br />

Model 4000-40BD3 89273<br />

*Must specify voltage when ordering. Choose from 120V/60Hz, 240/60Hz, or<br />

230V/50Hz. Two-year manufacturer’s warranty.<br />

6705<br />

6704<br />

Specifications<br />

Tank<br />

Size<br />

L/min<br />

Flow at<br />

80psig<br />

L/min<br />

Flow<br />

at<br />

60psig<br />

L/min<br />

Noise<br />

db(A)<br />

Approx..<br />

H x W x L<br />

Compressor<br />

Standard<br />

OF302-4B 4 57 60 66 13 x 12 x 15"<br />

(33 x 30 x 38cm)<br />

Weight.<br />

lb (kg)<br />

49 (31)<br />

OF302-25B 25 57 60 66 23 x 15 x 15" 62 (39)<br />

(58 x 38 x 38cm)<br />

2000-40B 40 120 130 72 25 x 21 x 17" 72 (45)<br />

(64 x 53 x 43cm)<br />

4000-40B 40 250 275 75 26 x 24 x 18" 185 (116)<br />

(66 x 61 x 46cm)<br />

w/Air Dryer<br />

OF302-4BD2 4 46 48 66 14 x 15 x 20" 59 (37)<br />

(36 x 38 x 51cm)<br />

OF302-25BD2 25 46 48 48 23 x 20 x 18" 73 (46)<br />

(58 x 51 x 46cm)<br />

2000-40BD2 40 96 104 72 25 x 20 x 23" 73 (46)<br />

(64 x 51 x 58cm)<br />

4000-40BD3 40 200 220 75 27 x 24 x 24" 214 (134)<br />

(69 x 61 x 61cm)<br />

w/Sound Cabinet<br />

OF302-4M 4 57 60 48 16 x 18 x 24" 99 (62)<br />

(41 x 46 x 61cm)<br />

OF302-25M 25 57 60 66 34 x 18 x 26" 172 (108)<br />

(86 x 46 x 66cm)<br />

2000-40M 40 120 130 52 34 x 25 x 26" 245 (153)<br />

(86 x 64 x 66cm)<br />

4000-40M 40 120 130 52 34 x 25 x 26" 245 (153)<br />

(86 x 64 x 66cm)<br />

Sound Cabinet and Air Dryer<br />

OF302-4MD2 4 46 48 48 16 x 18 x 28" 115 (72)<br />

(41 x 46 x 71cm)<br />

OF302-25MD2 25 46 48 48 34 x 18 x 26" 283 (177)<br />

(86 x 46 x 66cm)<br />

2000-40MD2 40 96 104 52 34 x 25 x 26" 256 (160)<br />

(86 x 64 x 66cm)<br />

4000-40MD3 40 96 104 52 34 x 25 x 26" 256 (160)<br />

(86 x 64 x 66cm)<br />

All compressors will go to 120psig maximum.<br />

gc instruments<br />

Standard with Sound Cabinet—M Series<br />

M series compressors are mounted inside<br />

a metal sound reduction cabinet. The<br />

sound cabinet also comes with vibration<br />

damping and cooling.<br />

Standard Compressors Installed with Air Dryer<br />

and Sound Cabinet<br />

The compressors with air dryers<br />

and sound cabinet have a reduced<br />

maintenance schedule due to their auto<br />

drain feature. They have additional<br />

cooling fans to reduce heat.<br />

Air Compressors with Sound Cabinet*<br />

Description<br />

Part No.<br />

Model OF302-4M 89346<br />

Model OF302-25M 89347<br />

Model 2000-40M 89329<br />

Model 4000-40M 89274<br />

*Must specify voltage when ordering. Choose from 120V/60Hz, 240/60Hz, or<br />

230V/50Hz. Two-year manufacturer’s warranty.<br />

6706<br />

Air Compressor with Sound Cabinet*<br />

Description<br />

Part No.<br />

Model OF302-4MD2 89349<br />

Model OF302-25MD2 89350<br />

Model 2000-40MD2 89331<br />

Model 4000-40MD3 89276<br />

*Must specify voltage when ordering. Choose from 120V/60Hz, 240/60Hz, or<br />

230V/50Hz. Two-year manufacturer’s warranty.<br />

6707<br />

www.discoverysciences.com<br />

211


gas chromatography<br />

gc instruments<br />

Equipment/Compressor Cross-Reference<br />

Equipment that Uses Compressors<br />

Model Flow Compressor<br />

Alltech ® ELSD Nitrogen Generator<br />

ELSD 4L/min OF302-25BD2<br />

Domnick Hunter ® LC/MS Generators<br />

LCMS30-1 30L/min 2000-40B<br />

LCMS30-0 30L/min 2000-40B<br />

Parker Balston ® LC/MS Generators<br />

N2-14 14-66L/min 2000-40B<br />

N2-22 14-66L/min 2000-40B<br />

Parker Balston ® UHP Nitrogen Generators<br />

HPN2-1100 500-1100mL/min 1000-25B<br />

UHPN2-1100 500-1100mL/min 2000-40B<br />

HPN2-2000 2L/min 2000-40B<br />

Parker ChromGas ® UHP Zero Air Generators<br />

1000 1.0L/min OF302-4B<br />

3500 3.5L/min OF302-4B<br />

Parker Balston ® Zero Air Generators<br />

75-83 1.0L/min OF302-4B<br />

HPZA-3500 3.5L/min OF302-4B<br />

HPZA-7000 7.0L/min OF302-4B<br />

HPZA-18000 18.0L/min 1000-25B<br />

HPZA-30000 30.0L/min 1000-25B<br />

Domnick Hunter ® Zero Air Generators<br />

UHP-10ZA 1.0L/min OF302-4B<br />

UHP-35ZA 3.5L/min OF302-4B<br />

UHP-75ZA 7.5L/min OF302-4B<br />

UHP-200ZA 20.0L/min 1000-25B<br />

UHP-350ZA 35.0L/min 1000-25B<br />

tech tip<br />

Choosing a tubing material<br />

A number of options are available for packed column tubing.<br />

The most inert material is glass, which should be used for active<br />

compounds. Glass-lined tubing and AT-Steel provide the inert<br />

surface of glass combined with the mechanical strength of a<br />

metal column.<br />

Metal tubing provides an economical and rugged column for<br />

suitable application. Passivated nickel tubing can frequently<br />

be used with active compounds such as phenols and amines.<br />

Stainless steel tubing is recommended for hydrocarbon, fixed<br />

gas, and solvent analyses where column inertness is less of<br />

a concern.<br />

PTFE tubing is extremely inert, but due to temperature limitations<br />

and poor column efficiency, PTFE is generally only recommended<br />

for the analysis of corrosive gases which are too reactive<br />

for glass.<br />

related product<br />

Stainless steel tubing<br />

We offer a full selection of lengths, IDs,<br />

and coating types to meet all of your<br />

GC tubing needs. See pages 386,<br />

388–389.<br />

related product<br />

Gas purifiers and traps<br />

A clean gas stream helps improve<br />

the quality of your GC analysis<br />

and the reliability of your results.<br />

For a full line of purifiers and<br />

traps in multiple styles, see pages<br />

266–270 and 277–279.<br />

related product<br />

Rotary tubing cutter<br />

Cut metal and glass-lined tubing with no<br />

deburring or reaming. See page 391.<br />

related product<br />

GC fittings<br />

For a full selection of stainless steel GC fittings,<br />

reducing unions, and other connectors, see pages<br />

282–285.<br />

related product<br />

Gas sampling bags<br />

We offer a broad selection of<br />

gas sampling bags in many<br />

sizes, materials, and shapes.<br />

See pages 273–275.<br />

related product<br />

Vials<br />

We have one of the largest selections<br />

of vials for all types of chromatography,<br />

including headspace vials, autosampler<br />

vials, and much more. See pages 348–378.<br />

5096<br />

4653<br />

5110<br />

5130<br />

6648<br />

4715<br />

212 www.discoverysciences.com


gas chromatography<br />

<strong>Grace</strong> ® GC Capillary Column Families<br />

• Alltech ® Heliflex ® —High-Performance, Widest Selection of Phases<br />

• Alltech ® Econo-Cap—Best Value, Popular Phases<br />

<strong>Grace</strong> offers two lines of capillary columns to suit every<br />

application and budget; Alltech ® Heliflex ® and Alltech ®<br />

Econo-Cap. Heliflex ® Columns are <strong>Grace</strong>’s premium line of<br />

individually tested capillary columns. Econo-Cap Columns<br />

are batch tested to dramatically reduce the price without<br />

sacrificing quality. Both the Heliflex ® and Econo-Cap lines<br />

are manufactured under identical conditions using the same<br />

high-quality polyimide coated fused silica and immobilized<br />

stationary phases. In addition each are mounted on a<br />

rugged cage.<br />

Regardless of the capillary line you choose, every <strong>Grace</strong><br />

manufactured capillary column has a guarantee of column<br />

performance.<br />

Alltech ® Heliflex ® Capillary Columns<br />

• High-performance individually<br />

tested columns<br />

• Choice of 5" or 7" rugged cage<br />

• Most complete selection<br />

of phases<br />

• Custom columns available to<br />

suit your specific application<br />

Heliflex ® Capillary Columns are manufactured from the<br />

highest quality polyimide coated synthetic fused silica.<br />

They are mounted on a rugged wear-resistant cage. Each<br />

Heliflex ® Column is individually tested to guarantee column<br />

performance and comes with a test chromatogram, instruction<br />

manual, capillary end caps, and a free ceramic column cutter.<br />

Note: Column nuts and ferrules are not included. If the<br />

column you need is not available in our standard offering,<br />

request a custom Heliflex ® Column made to your individual<br />

specifications.<br />

Alltech ® Econo-Cap Capillary Columns<br />

• Best value in capillary columns<br />

anywhere<br />

• Batch tested to dramatically<br />

reduce price<br />

• Ideal for aggressive applications<br />

• Available in the most popular<br />

phases<br />

premium<br />

value<br />

We’ve taken our most popular capillary columns and<br />

perfected the manufacturing procedure to the point that<br />

reproducibility is assured. This allows us to test these<br />

columns in batches instead of individually, while still offering<br />

a guarantee. Batch testing significantly reduces cost in<br />

production without sacrificing quality.<br />

Each Econo-Cap Capillary Column comes with a copy<br />

of the batch test results, an instruction manual, and capillary<br />

end caps. If you are not completely satisfied with the quality<br />

of your Econo-Cap Capillary Column it will be replaced<br />

at no charge.<br />

Available Alltech ® Heliflex ® Phases<br />

Phase<br />

Page<br />

AT-1ms 216<br />

AT-1ht 216<br />

AT-1 217<br />

AT-5ms 218<br />

AT-5 218<br />

AT-20 219<br />

AT-35ms 220<br />

AT-35 220<br />

AT-50 221<br />

AT-624 226<br />

AT-1301 221<br />

AT-1701 222<br />

AT-210 222<br />

AT-225 226<br />

AT-WAXms 223<br />

AT-WAX 223<br />

AT-AquaWax 224<br />

AT-AquaWax-DA 224<br />

AT-1000 225<br />

AT-FAME 225<br />

AT-CAM 225<br />

AT-Amino Acid 228<br />

Drug 1, Drug 2, and Drug 3 228<br />

USP Method 467 Kits 229<br />

AT-Pesticide 230<br />

AT-502.2 230<br />

AT-Petro 231<br />

AT-2887 231<br />

AT-3710 231<br />

AT-Sulfur 231<br />

AT-Amine 231<br />

AT-Silar-90 227<br />

AT-Silar-100 227<br />

Available Alltech ® Econo-Cap Phases<br />

Phase<br />

Page<br />

EC-1 217<br />

EC-5 219<br />

EC-20 219<br />

EC-WAX 224<br />

EC-1000 225<br />

tech tip<br />

Temperature limits<br />

Our GC capillary columns are temperature rated. In some cases,<br />

we list two maximum operating temperatures, the lower one is<br />

for isothermal condition and the higher one for temperatureprogrammed<br />

condition.<br />

5382<br />

gc columns | capillary<br />

Note: Column nuts and ferrules are not included.<br />

www.discoverysciences.com<br />

213


gas chromatography<br />

Capillary Column Phase Cross Reference<br />

Use the chart below to cross reference manufacturers’ stationary phases as well as USP method designations to Alltech<br />

equivalent columns. Slight variations in selectivity may result between different manufacturers’ columns.<br />

Alltech ® Standard Phase Cross Reference<br />

gc columns | capillary<br />

Standard Phase Cross Reference<br />

Composition<br />

Alltech Brand<br />

Usp<br />

Designation Similiar Phases<br />

100% Dimethylpolysiloxane AT-1ms G1, G2, G38 DB-1ms, HP-1ms, Rtx ® -1ms, CP-Sil 5CB low-bleed/ms<br />

100% Dimethylpolysiloxane AT-1ht, AT-1,<br />

EC-1<br />

G1, G2, G38 007-1, CP-Sil 5CB, DB-1, DB-1ht, HP-1, HP-101,<br />

OV-1, RSL-150, RSL-160, Rtx ® -1, SE-30, SPB-1, SPB-Sulfur,<br />

ULTRA-1, SP-2100, BP-1, DC-200, PE-1, ZB-1<br />

5% Phenyl equivalent<br />

Polysilphenylene-Siloxane<br />

AT-5ms<br />

DB-5ms, Rtx ® -5 Sil ms, BPX-5, 007-5ms, HP-5ms<br />

(5% Phenyl)-<br />

95% methylpolysiloxane<br />

(20% Phenyl)-<br />

80% methylpolysiloxane<br />

(35 Phenyl)-<br />

65% Methylpolysiloxane<br />

(50 Phenyl)-<br />

50% methylpolysiloxane<br />

(6% Cyanopropylphenyl)-<br />

94% methylpolysiloxane<br />

(14% Cyanopropylphenyl)-<br />

86% methylpolysiloxane<br />

Trifluoropropylmethyl<br />

polysiloxane<br />

(50% Cyanopropylphenyl)-<br />

50% methylpolysiloxane<br />

Poly(80% biscyanopropyl)-<br />

20% cyanoproylphenyl siloxane<br />

Poly(biscyanopropyl<br />

siloxane)<br />

Polyethyleneglycol<br />

Polyethyleneglycol<br />

Acid Modified<br />

AT-5,<br />

EC-5<br />

AT-20,<br />

EC-20<br />

AT-35ms<br />

AT-35<br />

G27,<br />

G36<br />

G28,<br />

G32<br />

G42<br />

007-2, CP-Sil 8CB, DB-5, DB-5.625, DB-5ht, HP-5,<br />

HP-5ms, OV-5, PTE-5, PTE-5QTM, PAS-5, RSL-200, Rtx ® -5, Rtx ® -5ms, SAC-5,<br />

SE-54, SPB-5, ULTRA-2, XTI-5, SE-52, BP-5, PE-2, ZB-5<br />

007-7, Rtx ® -20, SPB-20, VOCOL, PE-7<br />

DB-35ms, Rtx ® -35, SPB-35, Sup-Herb, MDN-35, BPX-35<br />

007-11, DB-35, DB-35ms, HP-35, RSL-300, Rtx ® -35, SPB-35, SPB-608,<br />

OV-11, PE-35, Sup-Herb<br />

AT-50 G3 DB-17ms, H5-50+, Rtx ® -50, SP-2250, SPB-50, SPB-17, BPX-50<br />

DB-17ht, Rtx ® -65TG, BPX-50, CP-TAB-CB,<br />

007-17, DB-17, DB-17ht, HP-17, HP-50+, Rtx ® -50<br />

SP-50, SP-2250, SPB-50, CP-Sil 24CB, PE-17, ZB-50<br />

AT-624<br />

G43 007-1301, DB-624, DB-1301, HP-1301, HP-624,<br />

AT-1301<br />

Rtx ® -1301, Rtx ® -624, SPB-1301, SPB-624, 007-624, ZB-624<br />

AT-1701<br />

007-1701, CP-Sil 19CB, DB-1701, HP-1701, OV-1701,<br />

PAS-1701, Rtx ® -1701, SPB-1701, BP-10, ZB-1701<br />

AT-210 G6 DB-210, RSL-400, Rtx ® -200, OV-202, OV-210, OV-215, QF-1, SP-2401<br />

AT-225 G7 007-225, CP-Sil 43CB, DB-225, HP-225, OV-225, RSL-500, Rtx ® -225,<br />

BP-225, PE-225<br />

AT-SILAR-90 G8 DB-23, CP-Sil 84, Rtx ® -2330, SP-2330<br />

AT-SILAR-100 G5 CP-Sil 88, Rtx ® -2330, SP-2340<br />

AT-WAXms<br />

AT-WAX<br />

AT-AquaWax<br />

EC-WAX<br />

AT-1000,<br />

EC-1000,<br />

AT-AquaWax-DA<br />

G14, G15<br />

G16, G20,<br />

G39<br />

G25,<br />

G35<br />

DB-WAX, Rtx ® -WAX, Supelcowax-10<br />

007-CW, Carbowax ® 20M, CP-Wax 52CB, DB-WAXetr,<br />

DB-WAX, Rtx ® -WAX, HP-20M, HP-Wax, Innowax,<br />

Omegawax, Stabilwax ® , Supelcowax ® -10, Superox ® II, BP-20, ZB-WAX<br />

007-FFAP, CP-Wax 58CB, DB-FFAP, HP-FFAP, Nukol,<br />

OV-351, SP-1000, Stabilwax ® -DA, Superox ® -FA, BP-21<br />

Polyethyleneglycol<br />

AT-CAM Stabilwax ® -DB, CAM, Carbowax ® Amine, CP Wax 51<br />

Base Modified<br />

PONA Analysis AT-Petro 007-1-100-0.5F, CP-Sil PONA CB, DB-Petro100, Petrocol DH, PONA,<br />

Ttx-1PONA, HP-PONA<br />

ASTM Method 2887 AT-2887 007-1-10V-1.0F, DB-2887, Petrocol 2887, Petrocol EX2887, Rtx ® -2887,<br />

Sim-Dist-CB<br />

ASTM Method 3710 AT-3710 Petrocol 3710<br />

Alltech ® Specialty Columns Cross Reference<br />

Specialty Phases Cross Reference<br />

EPA Method 608 AT-Pesticide 007-608, DB-608, HP-608, SPB-608<br />

EPA Method 502.2 AT-502.2 007-624, 007-502, DB-502.2, DB-VRX, HP-624,<br />

HP-VOC, MST-502.2, MXT-624, MXT-Volatiles, OV-624, Rtx ® -502.2, Rtx ® -624,<br />

Rtx-Volatiles, VOCOL<br />

Sulfur Analysis AT-Sulfur SPB-1 Sulfur<br />

FAME Analysis AT-FAME FAMEWAX, OmegaWAX<br />

214 www.discoverysciences.com


gas chromatography<br />

Alltech ® Custom Capillary Columns<br />

• A wide selection of stationary phases<br />

• Lengths from 1 to 105 meters<br />

• Wide selection of i.d. tubing<br />

• Every column individually tested<br />

Custom Capillary Column Instructions<br />

1. Stationary Phase: Choose a Phase in “Table 1: Custom<br />

Phase.”<br />

2. Length & Internal Diameter: Choose any length<br />

(1–105 meters) and internal diameter (0.10mm–0.53mm)<br />

in “Table 2: Custom Dimensions.”<br />

3. Film Thickness: Choose a film thickness; 0.01µm<br />

tolerance.<br />

4. See Coiling and Guard Information for additional options.<br />

5. Call Customer Service and they will confirm your order<br />

and provide exact prices.<br />

Table 1: Custom Phases<br />

Phases Available for Custom Capillary Columns<br />

• Aquawax<br />

• DC-550<br />

• Igepal CO-880<br />

• Aquawax-DA<br />

• Dexsil ® 300<br />

• OV-1<br />

• AT-1<br />

• Dexsil ® 400<br />

• OV-11<br />

• AT-5<br />

• Dexsil ® 410<br />

• OV-17<br />

• AT-20<br />

• Di (2ethylhexyl • OV-1701<br />

• AT-35<br />

phthalate<br />

• OV-61<br />

• AT-1000<br />

• Diisodecyl phthalate • OV-101<br />

• AT-1301<br />

• FFAP<br />

• OV-105<br />

• AT-1701<br />

• Hi-EFF-1AP • OV-210<br />

• AT-WAX<br />

• Hi-EFF-1BP • OV-351<br />

• AT-Amine<br />

• Hi-EFF-2AP • Polyvinylpyrrolidone<br />

• Apiezon ® phases • Hi-EFF-2BP • Reoplex 400<br />

• Apolane-87 • Hi-EFF-3AP • SE-30<br />

• Butanediol succinate • Hi-EFF-3BP • Squalane<br />

(Craig’s polyester) • Hi-EFF-4BP • Superox ® -FA<br />

• Carbowax ® phases • Hi-EFF-8BP • XE-60<br />

Table 2: Custom Dimensions<br />

Alltech ® Heliflex ® Custom Capillary Columns<br />

Length i.d. Description Part No.<br />

1– 5m 0.10mm Specify Phase and Film 971001<br />

0.18mm Specify Phase and Film 971005<br />

0.25mm Specify Phase and Film 972010<br />

0.32mm Specify Phase and Film 973010<br />

0.45mm Specify Phase and Film 974010<br />

0.53mm Specify Phase and Film 975010<br />

6 –15m 0.10mm Specify Phase and Film 971011<br />

0.18mm Specify Phase and Film 971014<br />

0.25mm Specify Phase and Film 972015<br />

0.32mm Specify Phase and Film 973015<br />

0.45mm Specify Phase and Film 974015<br />

0.53mm Specify Phase and Film 975015<br />

16 – 30m 0.10mm Specify Phase and Film 971028<br />

0.18mm Specify Phase and Film 971029<br />

0.25mm Specify Phase and Film 972030<br />

0.32mm Specify Phase and Film 973030<br />

0.45mm Specify Phase and Film 974030<br />

0.53mm Specify Phase and Film 975030<br />

31– 60m 0.18mm Specify Phase and Film 971050<br />

0.25mm Specify Phase and Film 972060<br />

0.32mm Specify Phase and Film 973060<br />

0.45mm Specify Phase and Film 974060<br />

0.53mm Specify Phase and Film 975060<br />

61–105m 0.25mm Specify Phase and Film 972105<br />

0.32mm Specify Phase and Film 973105<br />

0.45mm Specify Phase and Film 974105<br />

0.53mm Specify Phase and Film 975105<br />

Custom Capillary<br />

All other Dimensions not specified 970123<br />

Custom Capillary Coiling<br />

Custom Coiling<br />

Description<br />

Part No.<br />

Custom Capillary on 4" Cage 970124<br />

Custom Capillary on 5" Cage 970125<br />

gc columns | capillary<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

Custom Capillary Column with Integral Guard<br />

Custom Capillary Column with Integral Guard<br />

Description<br />

Part No.<br />

Custom 0.25mm i.d. with Integral 5m Guard C-5400<br />

Custom 0.32mm i.d. with Integral 5m Guard C-5500<br />

Custom 0.53mm i.d. with Integral 5m Guard C-5600<br />

www.discoverysciences.com<br />

215


gas chromatography<br />

Heliflex ® AT -1ms<br />

• Guaranteed low-bleed characteristics<br />

• Specifically designed for mass spec analysis<br />

• Highly inert<br />

• Similar to DB-1ms, HP-1ms, Rtx ® -1ms,<br />

CP-Sil 5CB low-bleed/MS, MDN-1<br />

AT-1ms is a line of high-performance low bleed nonpolar<br />

columns designed specifically for use with mass<br />

spectrometers. They are ideal for pharmaceutical,<br />

environmental, petrochemical, and food and fragrance<br />

analysis, or any GC/MS analysis requiring a 100%<br />

dimethylpolysiloxane-type polarity capillary column.<br />

premium<br />

Heliflex ® AT -1ht<br />

premium<br />

Shorten Your Analysis Time with .<br />

High-Temperature/Low-Bleed Columns<br />

• Faster analysis time for high boiling compounds<br />

• Better peak detection at lower concentrations<br />

• Individually bleed tested at 380ºC<br />

• Similar to 007-1, CP-Sil 5CB, DB-1, DB-1ht, HP-1, HP-101,<br />

OV TM -1, RSL-150, RSL-160, Rtx ® -1, SE-30, SPB TM -1,<br />

SPB TM -Sulfur, ULTRA-1, SP-2100, BP-1, DC-200,<br />

PE-1, ZB-1<br />

gc columns | capillary<br />

Heliflex ® AT-1ms Specifications<br />

Phase:<br />

100% Dimethylpolysiloxane<br />

Polarity:<br />

Non-polar<br />

Max. Temp.: 340/360°C<br />

USP Designation: G1, G2, G38<br />

Ideal For:<br />

Mass Spec Analysis for Environmental, PAH, CLP<br />

Pesticides, Steroids, and Drugs<br />

1<br />

4<br />

2<br />

3<br />

6 7 8<br />

5<br />

Figure 1 – AT-1ms Low Bleed<br />

9<br />

2578<br />

1. 2-Ethylhexanoic Acid<br />

2. 4-Chlorophenol<br />

3. 1,7-Heptanediol<br />

4. n-Tridecane<br />

5. 1-Undecanol<br />

6. n-Tetradecane<br />

7. Dicyclohexylamine<br />

8. Acenaphthylene<br />

9. n-Pentadecane<br />

Heliflex ® AT-1ht Specifications<br />

Phase:<br />

100% Dimethylpolysiloxane<br />

Polarity:<br />

Non-polar<br />

Max. Temp.: 380/400°C<br />

USP Designation: G1, G2, G38<br />

Ideal For:<br />

High Boiling Compounds Waxes, Crude Oils, and<br />

Trigylcerides<br />

1<br />

3<br />

2<br />

QC Test Chromatogram – Bleed Profile<br />

45<br />

2634<br />

1. 1-Undecanol<br />

2. Dicyclohexylamine<br />

3. 4-Chlorophenol<br />

4. n-Pentadecane<br />

5. Fluorene<br />

6. Anthracene<br />

7. n-Heptadecane<br />

3 pA<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Heliflex ® AT-1ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15897)<br />

Temp:<br />

135°C (20min hold) to 320°C (10min hold) at<br />

20°C/min<br />

Carrier Gas: Helium at 0.65mL/min (23.1cm/sec)<br />

Detector: FID<br />

3.4 pA<br />

0 5 10 15 20 25 30 35 40 45 50 Min.<br />

Column: Heliflex ® AT-1ht, 30m x 0.25mm x 0.10µm<br />

(Part No. 16368)<br />

Column Temp: 125ºC (25min hold) to 380ºC at 20ºC/min<br />

Carrier Gas: Helium at 26.3cm/sec<br />

Detector: FID at 390ºC<br />

Heliflex ® AT-1ms Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm -60–360°C 15880<br />

0.32mm 0.25µm -60–360°C 15882<br />

30m 0.25mm 0.10µm -60–360°C 15884<br />

0.25mm 0.25µm -60–360°C 15897<br />

0.25mm 0.25µm -60–360°C 15735*<br />

0.32mm 0.10µm -60–360°C 15922<br />

0.32mm 0.25µm -60–360°C 15938<br />

0.32mm 0.25µm -60–360°C 15739*<br />

60m 0.25mm 0.25µm -60–360°C 15941<br />

0.32mm 0.25µm -60–360°C 15944<br />

*Equipped with uncoated 5m integral guard column. Total column length is 35 meters.<br />

Heliflex ® AT-1ht GC Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

15m 0.25mm 0.1µm -60–380/400°C 16367<br />

30m 0.25mm 0.1µm -60–380/400°C 16368<br />

60m 0.25mm 0.1µm -60–380/400°C 16369<br />

*Isothermal/Temp. program.<br />

more info<br />

For more Capillary GC Applications, See the GC Applications<br />

Section pages 462–493.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

216 www.discoverysciences.com


gas chromatography<br />

Heliflex ® AT -1<br />

• Excellent general purpose columns<br />

• Similar to DB-1, Rtx ® -1, SPB-1, SPB-Sulfur,<br />

SP-2100, HP-1, HP-101, ULTRA-1, BP-1, CP-Sil 5CB,<br />

007-1, OV-1, SE-30, DC-200, RSL-150, RSL-160,<br />

PE-1, ZB-1<br />

Heliflex ® AT-1 Specifications<br />

Phase:<br />

100% Dimethylpolysiloxane<br />

Polarity:<br />

Non-polar General Purpose Column<br />

USP Designation: G1, G2, G38<br />

Ideal For:<br />

General Purpose<br />

premium<br />

Heliflex ® AT-1 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

10m 0.25mm 0.20µm ‐60–350°C 932510<br />

0.25mm 0.25µm ‐60–350°C 13752<br />

0.25mm 0.10µm ‐60–350°C 16866<br />

0.32mm 0.10µm ‐60–350°C 16868<br />

0.32mm 0.25µm ‐60–350°C 13755<br />

0.32mm 0.30µm ‐60–350°C 933210<br />

0.53mm 0.25µm ‐60–350°C 16840<br />

0.53mm 1.20µm ‐60–350°C 935110<br />

0.53mm 2.65µm ‐60–300°C 16849<br />

0.53mm 5.00µm ‐60–300°C 16842<br />

15m 0.25mm 0.10µm ‐60–350°C 13649<br />

0.25mm 0.20µm ‐60–350°C 932515<br />

0.25mm 0.25µm ‐60–350°C 13753<br />

0.25mm 1.00µm ‐60–350°C 13653<br />

0.32mm 0.10µm ‐60–350°C 13673<br />

0.32mm 0.25µm ‐60–350°C 13757<br />

0.32mm 0.30µm ‐60–350°C 933215<br />

0.32mm 1.00µm ‐60–350°C 13698<br />

0.32mm 3.00µm ‐60–350°C 13701<br />

0.32mm 5.00µm ‐60–300°C 16836<br />

0.53mm 0.15µm ‐60–350°C 13945<br />

0.53mm 0.25µm ‐60–350°C 14194<br />

0.53mm 0.50µm ‐60–350°C 14030<br />

0.53mm 1.00µm ‐60–350°C 13505<br />

0.53mm 1.20µm ‐60–350°C 935115<br />

0.53mm 1.50µm ‐60–330°C 13905<br />

0.53mm 2.65µm ‐60–300°C 16875<br />

0.53mm 3.00µm ‐60–300°C 13893<br />

0.53mm 5.00µm ‐60–300°C 16851<br />

25m 0.25mm 0.20µm ‐60–350°C 932525<br />

0.32mm 0.30µm ‐60–350°C 933225<br />

0.53mm 1.20µm ‐60–350°C 935125<br />

30m 0.25mm 0.10µm ‐60–350°C 13663<br />

0.25mm 0.20µm ‐60–350°C 932530<br />

0.25mm 0.25µm ‐60–350°C 13638<br />

0.25mm 1.00µm ‐60–350°C 13639<br />

0.32mm 0.10µm ‐60–350°C 13699<br />

0.32mm 0.25µm ‐60–350°C 13640<br />

0.32mm 0.30µm ‐60–350°C 933230<br />

0.32mm 1.00µm ‐60–350°C 13641<br />

0.32mm 3.00µm ‐60–300°C 13702<br />

0.32mm 5.00µm ‐60–300°C 16838<br />

0.53mm 0.50µm ‐60–350°C 14038<br />

0.53mm 1.00µm ‐60–350°C 13515<br />

0.53mm 1.20µm ‐60–350°C 935130<br />

0.53mm 1.50µm ‐60–330°C 13908<br />

30m 0.53mm 2.65µm ‐60–300°C 16876<br />

0.53mm 3.00µm ‐60–300°C 13897<br />

0.53mm 5.00µm ‐60–300°C 16843<br />

Heliflex ® AT-1 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

50m 0.25mm 0.20µm ‐60–350°C 932550<br />

0.32mm 0.30µm ‐60–350°C 933250<br />

0.53mm 1.20µm ‐60–350°C 13938<br />

60m 0.25mm 0.10µm ‐60–350°C 13672<br />

0.25mm 0.25µm ‐60–350°C 13666<br />

0.25mm 1.00µm ‐60–350°C 13667<br />

0.32mm 0.10µm ‐60–350°C 13700<br />

0.32mm 0.25µm ‐60–350°C 13668<br />

0.32mm 1.00µm ‐60–350°C 13669<br />

0.32mm 3.00µm ‐60–300°C 13703<br />

0.32mm 5.00µm ‐60–300°C 13704<br />

0.53mm 0.50µm ‐60–350°C 13898<br />

0.53mm 1.00µm ‐60–350°C 13533<br />

0.53mm 1.20µm ‐60–350°C 13809<br />

0.53mm 1.50µm ‐60–330°C 13930<br />

0.53mm 3.00µm ‐60–300°C 13902<br />

0.53mm 5.00µm ‐60–300°C 13810<br />

100m 0.25mm 0.25µm ‐60–350°C 13972<br />

0.32mm 0.25µm ‐60–350°C 13979<br />

0.53mm 1.20µm ‐60–350°C 13982<br />

Heliflex ® AT-1 Capillary Columns on 5" Cage<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm ‐60–350°C 137535<br />

0.32mm 0.25µm ‐60–350°C 137575<br />

0.32mm 1.00µm ‐60–350°C 136985<br />

0.53mm 1.00µm ‐60–350°C 135055<br />

0.53mm 1.50µm ‐60–350°C 139055<br />

30m 0.25mm 0.25µm ‐60–350°C 136385<br />

0.32mm 0.25µm ‐60–350°C 136405<br />

0.32mm 1.00µm ‐60–350°C 136415<br />

0.53mm 1.00µm ‐60–350°C 135155<br />

0.53mm 1.50µm ‐60–350°C 139085<br />

Econo-Cap EC -1<br />

• Batch tested to dramatically reduce price<br />

value<br />

Econo-Cap EC-1 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

10m 0.53mm 2.65µm ‐60–350°C 19678<br />

15m 0.45mm 1.00µm ‐60–350°C 19642<br />

0.53mm 1.20µm ‐60–350°C 19650<br />

30m 0.25mm 0.25µm ‐60–350°C 19652<br />

0.32mm 0.25µm ‐60–350°C 19651<br />

0.32mm 1.00µm ‐60–350°C 19660<br />

0.45mm 1.00µm ‐60–350°C 19644<br />

0.53mm 1.00µm ‐60–350°C 19664<br />

0.53mm 1.20µm ‐60–350°C 19656<br />

best<br />

value<br />

Econo-Cap EC-1 Capillary Columns, Six Pack<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

30m 0.25mm 0.25µm ‐60–350°C 196526<br />

30m 0.32mm 0.25µm ‐60–350°C 196516<br />

30m 0.53mm 1.20µm ‐60–350°C 196566<br />

gc columns | capillary<br />

www.discoverysciences.com<br />

217


gas chromatography<br />

Heliflex ® AT -5ms<br />

• Similar to DB-5ms, Rtx ® -5 Sil ms,<br />

HP-5TA, BPX-5, 007-5ms<br />

premium<br />

The AT -5ms capillaries are ideal for environmental,<br />

pharmaceutical, and petrochemical analysis, or any GC/MS<br />

analysis requiring a 5% phenyl-type polarity capillary column.<br />

Heliflex ® AT -5<br />

• Excellent general purpose columns<br />

• Similar to DB-5, Rtx ® -5, SPB-5, HP-5,<br />

ULTRA-2, BP-5, CP-Sil 8CB, 007-2, OV-5,<br />

SE-52, SE-54, RSL-200, ZB-5<br />

premium<br />

Heliflex ® AT-5ms Specifications<br />

Phase:<br />

(5% Phenyl)-95% Methoxpolysiloxane<br />

Polarity:<br />

Non-polar<br />

USP Designation: G27, G36<br />

Ideal For:<br />

Mass Spec Analysis—General Application<br />

Heliflex ® AT-5 Specifications<br />

Phase:<br />

(5% Phenyl)-95% Methylpolysiloxane<br />

Polarity:<br />

Non-polar<br />

Max. Temp.: 380/400°C<br />

USP Designation: G27, G36<br />

Ideal For:<br />

General Applications<br />

gc columns | capillary<br />

1. TEPP<br />

2. Sulfotepp<br />

3. Monocrotophos<br />

4. Dimethoate<br />

5. Dioxathion<br />

6. Terbufos<br />

7. Phosphamidon<br />

8. Malathion<br />

9. Parathion<br />

10. cis-Chlorfenvinphos<br />

11. trans-Chlorfenvinphos<br />

12. Ethion<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Organophosphorus Pesticides<br />

13. Famphur<br />

14. Carbophenothion<br />

15. Phosmet<br />

1<br />

2<br />

4<br />

6<br />

4 8 12 16 20 24 28 32 36 40 Min.<br />

Heliflex ® AT-5ms Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm -60–325/350°C 15801<br />

30m 0.25mm 0.10µm -60–325/350°C 15806<br />

0.25mm 0.25µm -60–325/350°C 15807<br />

0.25mm 0.25µm -60–325/350°C 15881*<br />

0.25mm 0.50µm -60–325/350°C 15808<br />

0.25mm 0.50µm -60–325/350°C 15889*<br />

0.25mm 1.00µm -60–325/350°C 15809<br />

0.32mm 0.10µm -60–325/350°C 15893<br />

0.32mm 0.25µm -60–325/350°C 15894<br />

0.32mm 0.25µm -60–325/350°C 15883*<br />

0.32mm 1.00µm -60–325/350°C 15895<br />

60m 0.25mm 0.10µm -60–325/350°C 15879<br />

0.25mm 0.25µm -60–325/350°C 15891<br />

0.25mm 1.00µm -60–325/350°C 15892<br />

0.32mm 0.25µm -60–325/350°C 15896<br />

*Isothermal/Temp. program.<br />

3<br />

5<br />

7<br />

8<br />

9<br />

12<br />

14<br />

17<br />

11 13 15 18<br />

10<br />

2469<br />

16. EPN<br />

17. Leptophos<br />

18. Azinphos-ethyl<br />

Heliflex ® AT-5ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15807)<br />

120°C (3min hold) to 285°C at 5°C/min (4min hold)<br />

Helium, 26cm/sec<br />

MSD<br />

16<br />

Heliflex ® AT-5 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

10m 0.25mm 0.20µm ‐60–350°C 952510<br />

0.32mm 0.30µm ‐60–350°C 953210<br />

0.53mm 0.25µm ‐60–350°C 16145<br />

0.53mm 1.20µm ‐60–350°C 955110<br />

0.53mm 2.65µm ‐60–300°C 16853<br />

0.53mm 5.00µm ‐60–300°C 16855<br />

15m 0.25mm 0.10µm ‐60–300°C 13705<br />

0.25mm 0.20µm ‐60–300°C 952515<br />

0.25mm 0.25µm ‐60–350°C 13758<br />

0.25mm 1.00µm ‐60–350°C 13706<br />

0.32mm 0.10µm ‐60–350°C 13709<br />

0.32mm 0.25µm ‐60–350°C 13887<br />

0.32mm 0.30µm ‐60–350°C 953215<br />

0.32mm 1.00µm ‐60–350°C 13710<br />

0.53mm 0.25µm ‐60–350°C 14196<br />

0.53mm 0.50µm ‐60–300°C 14039<br />

0.53mm 1.00µm ‐60–350°C 13569<br />

0.53mm 1.20µm ‐60–350°C 955115<br />

0.53mm 1.50µm ‐60–330°C 13906<br />

0.53mm 3.00µm ‐60–300°C 13894<br />

0.53mm 5.00µm ‐60–300°C 13896<br />

25m 0.25mm 0.20µm ‐60–350°C 952525<br />

0.32mm 0.30µm ‐60–350°C 953225<br />

0.53mm 1.20µm ‐60–350°C 955125<br />

30m 0.25mm 0.10µm ‐60–350°C 13707<br />

0.25mm 0.25µm ‐60–350°C 13656<br />

0.25mm 0.50µm ‐60–330°C 13309<br />

0.25mm 1.00µm ‐60–350°C 13657<br />

0.32mm 0.10µm ‐60–300°C 13711<br />

0.32mm 0.25µm ‐60–350°C 13658<br />

0.32mm 0.30µm ‐60–350°C 953230<br />

0.32mm 1.00µm ‐60–350°C 13659<br />

0.53mm 0.50µm ‐60–300°C 14045<br />

0.53mm 1.00µm ‐60–350°C 13798<br />

0.53mm 1.20µm ‐60–350°C 955130<br />

0.53mm 1.50µm ‐60–330°C 13909<br />

0.53mm 2.65µm ‐60–300°C 16857<br />

0.53mm 5.00µm ‐60–300°C 16859<br />

50m 0.25mm 0.20µm ‐60–350°C 952550<br />

0.32mm 0.30µm ‐60–300°C 953250<br />

0.53mm 1.20µm ‐60–350°C 13942<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

218 www.discoverysciences.com


gas chromatography<br />

Heliflex ® AT-5 Capillary Columns (continued)<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

60m 0.25mm 0.10um -60–350°C 13708<br />

0.25mm 0.20µm -60–350°C 952560<br />

0.25mm 0.25µm -60–350°C 13676<br />

0.25mm 1.00µm -60–350°C 13677<br />

0.32mm 0.10µm -60–350°C 13712<br />

0.32mm 0.25µm -60–350°C 13678<br />

0.32mm 0.30µm -60–350°C 953260<br />

0.32mm 1.00µm -60–350°C 13679<br />

0.53mm 0.50µm -60–350°C 13899<br />

0.53mm 1.00µm -60–350°C 14076<br />

0.53mm 1.20µm -60–350°C 13820<br />

0.53mm 1.50µm -60–330°C 13931<br />

0.53mm 3.00µm -60–350°C 13903<br />

0.53mm 5.00µm -60–300°C 13829<br />

100m 0.25mm 0.25µm -60–350°C 13973<br />

0.32mm 0.25µm -60–350°C 14011<br />

0.53mm 1.20µm -60–350°C 14019<br />

Heliflex ® AT-5 Capillary Columns on 5" Cage<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm -60–350°C 137585<br />

0.32mm 0.25µm -60–350°C 138875<br />

0.32mm 1.00µm -60–350°C 137105<br />

0.53mm 1.00µm -60–350°C 135695<br />

0.53mm 1.50µm -60–350°C 139065<br />

30m 0.25mm 0.25µm -60–350°C 136565<br />

0.32mm 0.25µm -60–350°C 136585<br />

0.32mm 1.00µm -60–350°C 136595<br />

0.53mm 1.00µm -60–350°C 137985<br />

0.53mm 1.50µm -60–350°C 139095<br />

Heliflex ® AT -20<br />

• Unique polarity between non-polar and<br />

mid-range<br />

• Similar to 007-7, Rtx ® -20, SPB TM -20, VOCOL TM , PE-7<br />

Heliflex ® AT-20 Specifications<br />

Phase:<br />

(20% Phenyl)-80% Methylpolysiloxane<br />

Polarity:<br />

Intermediate Polarity<br />

USP Designation: G28, G32<br />

Ideal For:<br />

Volatile Compounds and Solvents<br />

premium<br />

Heliflex ® AT-20 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

10m 0.53mm 1.20µm ‐20–320°C 13936<br />

15m 0.25mm 0.25µm ‐20–320°C 13838<br />

0.32mm 0.25µm ‐20–320°C 13849<br />

0.53mm 1.20µm ‐20–320°C 13919<br />

0.53mm 1.00µm ‐20–300°C 13880<br />

25m 0.53mm 1.20µm ‐20–320°C 13934<br />

30m 0.25mm 0.25µm ‐20–320°C 13857<br />

0.32mm 0.25µm ‐20–320°C 13859<br />

0.53mm 1.00µm ‐20–300°C 13882<br />

0.53mm 1.20µm ‐20–300°C 13932<br />

50m 0.53mm 1.20µm ‐20–320°C 13944<br />

60m 0.25mm 0.25µm ‐20–320°C 13868<br />

0.32mm 0.25µm ‐20–320°C 13869<br />

0.53mm 1.00µm ‐20–300°C 13884<br />

0.53mm 3.00µm ‐20–280°C 13324<br />

gc columns | capillary<br />

Econo-Cap EC -5<br />

• Batch tested to dramatically reduce price<br />

value<br />

Econo-Cap EC -20<br />

• Batch tested to dramatically reduce price<br />

value<br />

Econo-Cap EC-5 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

15m 0.45mm 1.00µm -60–350°C 19661<br />

0.53mm 1.20µm -60–350°C 19645<br />

30m 0.25mm 0.25µm -60–350°C 19647<br />

0.32mm 0.25µm -60–350°C 19646<br />

0.32mm 1.00µm -60–350°C 19665<br />

0.53mm 1.00µm -60–350°C 19671<br />

0.53mm 1.20µm -60–350°C 19657<br />

best<br />

value<br />

Econo-Cap EC-5 Capillary Columns, Six Pack<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm -60–350°C 19649<br />

30m 0.25mm 0.25µm -60–350°C 196476<br />

0.32mm 0.25µm -60–350°C 196466<br />

0.53mm 1.20µm -60–350°C 196576<br />

Econo-Cap EC-20 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

15m 0.45mm 1.00µm ‐20–300°C 19670<br />

0.53mm 1.20µm ‐20–300°C 19673<br />

6515<br />

related products<br />

Parker Balston ® FID gas station<br />

The Parker Balston ® FID gas station combines<br />

Parker’s zero air and hydrogen generation<br />

technologies into a single unit, eliminating the<br />

inconveniences and cost of hydrogen and gas<br />

cylinders. See page 208.<br />

www.discoverysciences.com<br />

219


gas chromatography<br />

Heliflex ® AT -35ms<br />

premium<br />

• Guaranteed low-bleed<br />

• Specifically designed for mass spec analysis<br />

• Similar to DB-35ms, Rtx ® -35, SPB TM -35, Sup-Herb TM ,<br />

MDN-35, BPX-35<br />

Heliflex ® AT -35<br />

• Ideal column for conformational analysis<br />

• Similar to DB-35, DB-35ms, Rtx ® -35, BPX-35,<br />

SPB-35, SPB-608, HP-35, 007-11, OV-11,<br />

RSL-300, PE-35, Sup-Herb TM , ZB-35<br />

premium<br />

Heliflex ® AT-35ms Specifications<br />

Phase:<br />

(35% Phenyl)-65% Methylpolysiloxane<br />

Polarity:<br />

Intermediate Polarity<br />

USP Designation: G42<br />

Ideal For:<br />

Pesticides, Herbicides, Drugs, Aromatics<br />

Heliflex ® AT-35 Specifications<br />

Phase:<br />

(35% Phenyl)-65% Methylpolysiloxane<br />

Polarity:<br />

Intermediate Polarity<br />

USP Designation: G42<br />

Ideal For:<br />

Pesticides, Herbicides, Drugs, Aromatics<br />

gc columns | capillary<br />

Heliflex ® AT-35ms Capillary Column<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm -40–340°C 12588<br />

30m 0.25mm 0.25µm -40–340°C 12589<br />

60m 0.25mm 0.25µm -40–340°C 12590<br />

Tocopherols<br />

0 1 2 3 4 5 6 Min.<br />

Column: Heliflex ® AT-35, 25m x 0.25mm x 0.20µm<br />

(Part No. 962525)<br />

Temp: 310°C<br />

Carrier:<br />

Hydrogen at 40cm/sec<br />

Detector: FID<br />

1<br />

2<br />

3<br />

4<br />

1273<br />

1 . d-δ-Tocopherol<br />

2 . d-β-Tocopherol<br />

3 . d-γ-Tocopherol<br />

4 . d-α-Tocopherol<br />

Heliflex ® AT-35 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

10m 0.25mm 0.25µm -20–320°C 19613<br />

0.32mm 0.10µm -20–350°C 16872<br />

0.32mm 0.25µm -20–300°C 13759<br />

0.53mm 0.10µm -20–350°C 16861<br />

0.53mm 0.20µm -20–280°C 16865<br />

0.53mm 1.20µm -20–300°C 965110<br />

0.53mm 2.65µm -20–280°C 16877<br />

15m 0.25mm 0.25µm -20–320°C 13943<br />

0.25mm 0.50µm -20–320°C 13713<br />

0.32mm 0.15µm -20–280°C 13714<br />

0.32mm 0.25µm -20–320°C 13760<br />

0.32mm 0.50µm -20–320°C 13091<br />

0.53mm 1.00µm -20–300°C 14129<br />

0.53mm 1.20µm -20–300°C 965115<br />

25m 0.25mm 0.20µm -20–320°C 962525<br />

0.32mm 0.30µm -20–320°C 963225<br />

0.53mm 1.20µm -20–300°C 965125<br />

30m 0.25mm 0.15µm -20–320°C 13432<br />

0.25mm 0.20µm -20–300°C 962530<br />

0.25mm 0.25µm -20–320°C 13642<br />

0.25mm 0.50µm -20–320°C 13643<br />

0.25mm 1.00µm -20–300°C 13796<br />

0.32mm 0.15µm -20–320°C 13716<br />

0.32mm 0.25µm -20–320°C 13644<br />

0.32mm 0.50µm -20–320°C 13645<br />

0.53mm 0.50µm -20–320°C 13797<br />

0.53mm 1.00µm -20–300°C 14001<br />

0.53mm 1.20µm -20–300°C 965130<br />

0.53mm 2.65µm -20–280°C 16878<br />

50m 0.25mm 0.20µm -20–320°C 962550<br />

0.32mm 0.30µm -20–320°C 963250<br />

60m 0.25mm 0.20µm -20–320°C 962560<br />

0.25mm 0.25µm -20–320°C 13682<br />

0.25mm 0.50µm -20–320°C 13683<br />

0.32mm 0.25µm -20–320°C 13684<br />

0.32mm 0.50µm -20–320°C 13685<br />

0.53mm 1.00µm -20–320°C 14070<br />

more info<br />

For more Capillary GC Applications, See the GC Applications<br />

Section pages 462–493.<br />

220 www.discoverysciences.com


gas chromatography<br />

Heliflex ® AT -50<br />

• General purpose column<br />

• Similar to DB-17, DB-17ht, Rtx ® -50, BPX TM -50,<br />

SPB TM -50, SP-2250, HP-50+, HP-17, 007-17,<br />

OV-17, CP-Sil 24CB, PE-17, ZB-50<br />

premium<br />

Heliflex ® AT -1301<br />

• Unique polarity makes it ideal for a range<br />

of applications<br />

• Similar to BP624, DB-1301, Rtx ® -1301, Rtx ® -624,<br />

HP-1301, HP-624, DB-624, 007-624, 007-1301,<br />

SPB-1301, SPB TM -624, ZB-624<br />

premium<br />

Heliflex ® AT-50 Specifications<br />

Phase:<br />

(50% Phenyl)-Methylpolysiloxane<br />

Polarity: Intermediate Polarity<br />

USP Code: G3<br />

Ideal For: Pesticides, Herbicides, Phthalate Esters, Free Phenols,<br />

and Basic Drugs<br />

Heliflex ® AT-1301 Specifications<br />

Phase:<br />

(6% Cyanopropylpenyl)-Methylpolysiloxane<br />

Polarity: Intermediate Polarity<br />

USP Code: G43<br />

Ideal For: Volatile Organics, Pharmaceuticals, and<br />

EPA Method 612<br />

Heliflex ® AT-50 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm 40–325°C 13837<br />

0.32mm 0.25µm 40–325°C 13856<br />

0.53mm 1.00µm 40–280°C 13876<br />

30m 0.25mm 0.25µm 40–325°C 13839<br />

0.32mm 0.25µm 40–325°C 13858<br />

0.53mm 0.50µm 40–300°C 13991<br />

0.53mm 1.00µm 40–280°C 13878<br />

related product<br />

Stainless steel tubing<br />

We offer a full selection of lengths, IDs,<br />

and coating types to meet all of your<br />

GC tubing needs. See pages 386,<br />

388–389.<br />

5096<br />

Heliflex ® AT-1301 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

30m 0.25mm 0.25µm -20–280°C 13959<br />

0.25mm 1.00µm -20–260°C 13962<br />

0.32mm 0.25µm -20–280°C 14123<br />

0.53mm 1.00µm -20–260°C 13970<br />

0.53mm 3.00µm -20–260°C 15562<br />

more info<br />

For Capillary GC Applications, see the GC Applications Section,<br />

pages 462–493.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

gc columns | capillary<br />

related product<br />

GC fittings<br />

For a full selection of stainless steel GC fittings,<br />

reducing unions, and other connectors, see pages<br />

282–285.<br />

5130<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

related product<br />

Vials<br />

We have one of the largest selections<br />

of vials for all types of chromatography,<br />

including headspace vials, autosampler<br />

vials, and much more. See pages 348–378.<br />

4715<br />

www.discoverysciences.com<br />

221


gas chromatography<br />

Heliflex ® AT -210<br />

• Similar to DB- 210, Rtx ® -200, OV- 202,<br />

OV-210, OV-215, QF-1, SP-2401, RSL-400<br />

premium<br />

Heliflex ® AT -1701<br />

• Similar to DB-1701, OV-1701, SPB-1701,<br />

Rtx ® -1701, 007-1701, PAS-1701, CP-Sil 19CB,<br />

HP-1701, BP-10, ZB-1701<br />

premium<br />

Heliflex ® AT-210 Specifications<br />

Phase: Trifluoropropyl Methylpolysiloxane<br />

Polarity: Polar<br />

USP Code: G6<br />

Ideal For: Ketones, Aldehydes, Silanes, Glycols, Nitro Aromatics,<br />

Herbicides, and Method 8140 and 609<br />

Heliflex ® AT-1701 Specifications<br />

Phase:<br />

(14% Cyanopropylphenyl)-86% Methylpolysiloxane<br />

Polarity: Intermediate Polarity<br />

USP Code: n/a<br />

Ideal For: Pesticides, PCB’s, Drugs, Herbicides, and TMS Sugars<br />

gc columns | capillary<br />

Heliflex ® AT-210 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

10m 0.53mm 1.20µm 45–240°C 985110<br />

15m 0.32mm 0.15µm 45–260°C 13724<br />

0.32mm 0.25µm 45–260°C 13888<br />

0.53mm 1.00µm 45–240°C 13127<br />

0.53mm 1.20µm 45–240°C 985115<br />

25m 0.53mm 1.20µm 45–240°C 985125<br />

30m 0.32mm 0.15µm 45–260°C 13726<br />

0.32mm 0.25µm 45–260°C 13840<br />

0.32mm 0.50µm 45–260°C 13727<br />

0.53mm 1.00µm 45–240°C 13136<br />

0.53mm 1.20µm 45–240°C 985130<br />

60m 0.32mm 0.30µm 45–260°C 983260<br />

1. Monochloroacetic Acid<br />

2. Monobromoacetic Acid<br />

3. Dalapon<br />

4. Dichloroacetic Acid<br />

5. Trichloroacetic Acid<br />

6. Bromochloroacetic Acid<br />

7. Dibromoacetic Acid<br />

0<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

EPA Method 552.1: Haloacetic Acids<br />

1<br />

4<br />

2<br />

3<br />

2 4 6 8 10 12 14 16 18 Min.<br />

5<br />

6<br />

7<br />

2105<br />

Heliflex ® AT-1701, 30m x 0.32mm x 0.25µm<br />

(Part No. 13690)<br />

50°C (10min hold) to 120°C at 10°C/min<br />

Helium at 35cm/sec<br />

ECD<br />

Heliflex ® AT-1701 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

10m 0.25mm 0.20µm -20–280°C 942510<br />

0.53mm 1.20µm -20–280°C 945110<br />

15m 0.25mm 0.25µm -20–280°C 13881<br />

0.25mm 1.00µm -20–280°C 13718<br />

0.32mm 0.25µm -20–280°C 13762<br />

0.32mm 1.00µm -20–280°C 13720<br />

0.53mm 0.50µm -20–280°C 14046<br />

0.53mm 1.00µm -20–280°C 14074<br />

0.25mm 0.20µm -20–280°C 942515<br />

0.32mm 0.15µm -20–280°C 13719<br />

0.53mm 1.20µm -20–280°C 945115<br />

25m 0.25mm 0.20µm -20–280°C 942525<br />

0.32mm 0.30µm -20–280°C 943225<br />

0.53mm 1.20µm -20–280°C 945125<br />

30m 0.25mm 0.15µm -20–280°C 13417<br />

0.25mm 0.25µm -20–280°C 13686<br />

0.25mm 1.00µm -20–280°C 13687<br />

0.32mm 0.25µm -20–280°C 13690<br />

0.32mm 0.25µm -20–280°C 13106*<br />

0.32mm 1.00µm -20–280°C 13691<br />

0.53mm 0.50µm -20–280°C 14105<br />

0.53mm 1.00µm -20–280°C 13795<br />

0.53mm 1.20µm -20–280°C 13830<br />

50m 0.25mm 0.20µm -20–280°C 942550<br />

0.32mm 0.30µm -20–280°C 943250<br />

60m 0.25mm 0.15µm -20–280°C 13404<br />

0.25mm 0.25µm -20–280°C 13688<br />

0.25mm 1.00µm -20–280°C 13689<br />

0.32mm 0.15µm -20–280°C 13434<br />

0.32mm 0.25µm -20–280°C 13692<br />

0.32mm 1.00µm -20–280°C 13693<br />

0.53mm 0.50µm -20–280°C 14107<br />

0.53mm 1.00µm -20–280°C 14131<br />

*10-meter integral guard column.<br />

Heliflex ® AT-1701 Capillary Columns on 5" Cage<br />

Temp. Range<br />

Length i.d. Film<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm -20–280°C 138815<br />

0.32mm 0.25µm -20–280°C 137625<br />

0.32mm 1.00µm -20–280°C 137205<br />

0.53mm 1.00µm -20–280°C 140745<br />

0.53mm 1.20µm -20–280°C 9451155<br />

30m 0.25mm 0.25µm -20–280°C 136865<br />

0.32mm 0.25µm -20–280°C 136905<br />

0.32mm 1.00µm -20–280°C 136915<br />

0.53mm 1.00µm -20–280°C 137955<br />

0.53mm 1.20µm -20–280°C 138305<br />

222 www.discoverysciences.com


gas chromatography<br />

Heliflex ® AT -WAXms<br />

• Designed to provide low MS bleed<br />

• Similar to DB-WAX, Rtx ® -WAX,<br />

Supelcowax TM -10<br />

Heliflex ® AT-WAXms Specifications<br />

Phase:<br />

100% Polyethylene Glycol<br />

Polarity: Polar<br />

USP Code: G14, G15, G16, G39<br />

Ideal For: Mass Spec Analysis<br />

Heliflex ® AT-WAXms Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm 40–260°C 12603<br />

0.32mm 0.25µm 40–260°C 12606<br />

0.53mm 1.00µm 40–260°C 12610<br />

30m 0.25mm 0.25µm 40–260°C 12604<br />

0.32mm 0.25µm 40–260°C 12607<br />

0.53mm 1.00µm 40–260°C 12611<br />

60m 0.25mm 0.25µm 40–260°C 12605<br />

0.32mm 0.25µm 40–260°C 12608<br />

Heliflex ® AT -WAX<br />

premium<br />

premium<br />

• Similar to DB-WAX, DB-WAXetr, Rtx ® -WAX,<br />

Stabilwax ® , Carbowax ® 20M, Supelcowax TM -10,<br />

Innowax, HP-20M, HP-Wax, BP-20, CP-Wax 52-CB,<br />

007-CW, Superox ® II, OmegaWAX, ZB-WAX<br />

Heliflex ® AT-WAX Specifications<br />

Phase:<br />

100% Polyethylene Glycol<br />

Polarity: Polar<br />

USP Code: G14, G15, G16, G39<br />

Ideal For: FAMEs, Polar Solvents, BTEX, Flavor and Fragrances,<br />

Glycols, Alcohols, and Aromatics<br />

Heliflex ® AT-WAX Capillary Columns (continued)<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

15m 0.32mm 2.50µm 40–260°C 137372<br />

0.53mm 0.50µm 40–260°C 14109<br />

0.53mm 1.00µm 40–260°C 13904<br />

0.53mm 1.20µm 40–260°C 9951152<br />

0.53mm 150µm 40–250°C 13215<br />

0.53mm 2.50µm 40–250°C 16881<br />

0.53mm 5.00µm 40–250°C 16883<br />

25m 0.25mm 0.20µm 40–280°C 9925252<br />

0.32mm 0.30µm 40–280°C 9932252<br />

0.53mm 1.20µm 40–260°C 9951252<br />

30m 0.25mm 0.15µm 40–280°C 13418<br />

0.25mm 0.20µm 40–280°C 9925302<br />

0.25mm 0.25µm 40–280°C 136462<br />

0.25mm 0.50µm 40–260°C 136472<br />

0.32mm 0.25µm 40–280°C 136482<br />

0.32mm 0.30µm 40–280°C 9932302<br />

0.32mm 0.50µm 40–260°C 136522<br />

0.32mm 1.00µm 40–260°C 137382<br />

0.53mm 0.50µm 40–260°C 14111<br />

0.53mm 1.00µm 40–260°C 13907<br />

0.53mm 1.20µm 40–260°C 9951302<br />

0.53mm 1.50µm 40–260°C 13109<br />

0.53mm 2.00µm 40–250°C 16162<br />

0.53mm 2.50µm 40–250°C 16885<br />

0.53mm 5.00µm 40–250°C 16887<br />

50m 0.25mm 0.20µm 40–280°C 9925502<br />

0.32mm 0.30µm 40–280°C 9932502<br />

0.53mm 1.20µm 40–260°C 13946<br />

60m 0.25mm 0.20µm 40–280°C 9925602<br />

0.25mm 0.25µm 40–280°C 136942<br />

0.25mm 0.50µm 40–260°C 13916<br />

0.32mm 0.25µm 40–280°C 136962<br />

0.32mm 0.30µm 40–280°C 9932602<br />

0.32mm 0.50µm 40–260°C 136972<br />

0.53mm 0.50µm 40–260°C 13901<br />

0.53mm 1.00µm 40–260°C 13929<br />

0.53mm 1.20µm 40–260°C 13850<br />

0.53mm 1.50µm 40–260°C 13243<br />

gc columns | capillary<br />

Heliflex ® AT-WAX Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

10m 0.25mm 0.25µm 40–280°C 19615<br />

0.25mm 0.20µm 40–280°C 9925102<br />

0.32mm 0.25µm 40–280°C 13778<br />

0.53mm 1.20µm 40–260°C 9951102<br />

15m 0.25mm 0.15µm 40–280°C 13433<br />

0.25mm 0.20µm 40–280°C 9925152<br />

0.25mm 0.25µm 40–280°C 13777<br />

0.25mm 0.50µm 40–260°C 137302<br />

0.25mm 1.00µm 40–260°C 137312<br />

0.32mm 0.25µm 40–280°C 13779<br />

0.32mm 0.30µm 40–280°C 9932152<br />

0.32mm 0.50µm 40–260°C 137352<br />

0.32mm 1.00µm 40–260°C 137362<br />

Heliflex ® AT-WAX Capillary Columns on 5" Cage<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm 40–280°C 137755<br />

0.32mm 0.25µm 40–280°C 137785<br />

0.32mm 1.00µm 40–260°C 1373625<br />

0.53mm 1.00µm 40–260°C 139045<br />

0.53mm 1.20µm 40–260°C 99511525<br />

30m 0.25mm 0.25µm 40–280°C 1364625<br />

0.32mm 0.25µm 40–280°C 1364825<br />

0.32mm 1.00µm 40–260°C 1373825<br />

0.53mm 1.00µm 40–260°C 139075<br />

0.53mm 1.20µm 40–260°C 99513025<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

www.discoverysciences.com<br />

223


gas chromatography<br />

gc columns | capillary<br />

Econo-Cap EC -WAX<br />

• Batch tested to dramatically reduce price<br />

• For phase specifications, see<br />

Heliflex ® AT version<br />

Econo-Cap EC-WAX Capillary Columns<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

15m 0.45mm 1.00µm 40–260°C 19667<br />

0.53mm 1.00µm 40–260°C 19674<br />

0.53mm 1.20µm 40–260°C 19653<br />

30m 0.25mm 0.25µm 40–280°C 19655<br />

0.32mm 0.25µm 40–280°C 19654<br />

0.45mm 1.00µm 40–260°C 19663<br />

0.53mm 1.00µm 40–260°C 19676<br />

0.53mm 1.20µm 40–260°C 19659<br />

Econo-Cap EC-WAX Six-Pack Capillary Columns<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

30m 0.25mm 0.25µm 40–260°C 196556<br />

0.32mm 0.25µm 40–260°C 196546<br />

0.53mm 1.20µm 40–260°C 196596<br />

more info<br />

For more information on the Econo-Cap Capillary Line, refer to<br />

page 213.<br />

Heliflex ® AT -AquaWax<br />

• Designed and tested for aqueous injections<br />

• Similar to DB-Wax, DB-Waxer, Rtx ® -WAX,<br />

Stabilwax ® , HP-Wax, HP-20M, HP-Innowax,<br />

ZB-Wax, and Supelcowax TM -10<br />

value<br />

best<br />

value<br />

premium<br />

Heliflex ® AT -AquaWax-DA<br />

• Designed and tested for aqueous injections<br />

• Eliminates the need for derivatization of<br />

acidic organic compounds<br />

• Similar to DB-FFAP, Stabilwax ® , HP-FFAP-DA,<br />

ZB-FFAP, SPB TM -1000, and Nukol<br />

Heliflex ® AT-AquaWax-DA Specifications<br />

Phase: 100% Polyethylene Glycol—Nitroterephthal Acid Modified<br />

Polarity: Polar<br />

USP Code: n/a<br />

Ideal For: Analysis of Acidic Organic Compounds and Free<br />

Fatty Acids<br />

Heliflex ® AT-AquaWax-DA Capillary Columns<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

30m 0.25mm 0.25µm 40–250°C 14537<br />

0.32mm 0.25µm 40–250°C 14539<br />

0.53mm 1.00µm 40–250°C 14543<br />

60m 0.25mm 0.25µm 40–250°C 14547<br />

0.32mm 0.25µm 40–250°C 14549<br />

1<br />

3<br />

2<br />

Free Fatty Acids<br />

4 5<br />

6<br />

premium<br />

2528<br />

1. Propionic Acid<br />

2. Butyric Acid<br />

3. Valeric Acid<br />

4. Caproic Acid<br />

5. Heptanoic Acid<br />

6. Caprylic Acid<br />

Heliflex ® AT-AquaWax Specifications<br />

Phase:<br />

100% Polyethylene Glycol<br />

Polarity: Polar<br />

USP Code: n/a<br />

Ideal For: Food and Beverage Analysis<br />

0<br />

2 4 6 8 10 Min.<br />

Heliflex ® AT-AquaWax Capillary Columns<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

30m 0.25mm 0.25µm 40–260°C 12437<br />

0.32mm 0.25µm 40–260°C 12439<br />

60m 0.25mm 0.25µm 40–260°C 12447<br />

0.32mm 0.25µm 40–260°C 12449<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

Column: Heliflex ® AT-AquaWax-DA, 30m x 0.25mm x<br />

0.25µm (Part No. 14537)<br />

Temp: 180°C<br />

Carrier Gas: Helium at 22cm/sec<br />

Detector: FID<br />

more info<br />

For Capillary GC Applications, see the GC Applications Section,<br />

pages 462–493.<br />

224 www.discoverysciences.com


gas chromatography<br />

Heliflex ® AT -1000<br />

• Similar to DB-FFAP, Stabilwax ® -DA,<br />

SPB-1000, Nukol, HP-FFAP, BP-21,<br />

CP-Wax-58-CB, 007-FFAP, OV-351, FFAP,<br />

Superox ® -FA, ZB-FFAP<br />

premium<br />

Heliflex ® AT -CAM<br />

• Eliminates need for derivitazation<br />

• Similar to Stabilwax ® -DB, Carbowax ® Amine,<br />

CAM, CP-Wax 51<br />

premium<br />

Heliflex ® AT-1000 Specifications<br />

Phase:<br />

100% Polyethylene Glycol—Acid Modified<br />

Polarity: High Polarity<br />

USP Code: G25, G35<br />

Ideal For: Free Fatty Acids<br />

Heliflex ® AT-1000 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

10m 0.25mm 0.20µm 40–250°C 972510<br />

0.32mm 0.30µm 40–250°C 973210<br />

0.53mm 1.20µm 40–250°C 975110<br />

15m 0.25mm 0.20µm 40–250°C 972515<br />

0.25mm 0.25µm 40–250°C 13782<br />

0.32mm 0.25µm 40–250°C 13886<br />

0.32mm 0.30µm 40–250°C 973215<br />

0.53mm 1.00µm 40–250°C 13873<br />

0.53mm 1.20µm 40–250°C 975115<br />

25m 0.25mm 0.20µm 40–250°C 972525<br />

0.32mm 0.30µm 40–250°C 973225<br />

0.53mm 1.20µm 40–250°C 975125<br />

30m 0.25mm 0.20µm 40–250°C 972530<br />

0.25mm 0.25µm 40–250°C 13783<br />

0.32mm 0.25µm 40–250°C 13785<br />

0.32mm 0.30µm 40–250°C 973230<br />

0.53mm 1.00µm 40–250°C 13877<br />

0.53mm 1.20µm 40–250°C 975130<br />

0.53mm 2.00µm 40–250°C 13017<br />

50m 0.25mm 0.20µm 40–250°C 972550<br />

0.32mm 0.30µm 40–250°C 973250<br />

60m 0.25mm 0.20µm 40–250°C 972560<br />

0.25mm 0.25µm 40–250°C 13784<br />

0.32mm 0.25µm 40–250°C 13786<br />

0.32mm 0.30µm 40–250°C 973260<br />

0.32mm 1.00µm 40–250°C 13276<br />

0.53mm 1.00µm 40–250°C 13879<br />

Heliflex ® AT-CAM Specifications<br />

Phase:<br />

100% Polyethylene Glycol—Base Modified<br />

Polarity: High Polarity<br />

USP Code: G25, G35<br />

Ideal For: Basic Compounds, Amines<br />

Heliflex ® AT-CAM Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

30m 0.32mm 0.25µm 40–250°C 13024<br />

0.53mm 0.50µm 40–250°C 13026<br />

0.53mm 1.00µm 40–250°C 13028<br />

Heliflex ® AT -FAME<br />

• Similar to FAMEWAX and OmegaWAX<br />

Heliflex ® AT-FAME Specifications<br />

Phase:<br />

Stable Bonded Polyethylene Glycol<br />

Polarity: High Polarity<br />

USP Code: G25, G35<br />

Ideal For: Fatty Acid Methyl Esters<br />

Heliflex ® AT-FAME Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

30m 0.25mm 0.25µm 40–280°C 12436<br />

0.32mm 0.25µm 40–280°C 12438<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

gc columns | capillary<br />

Econo-Cap EC -1000<br />

• Batch tested to dramatically reduce price<br />

• For phase specifications, see Heliflex ® AT version<br />

value<br />

Econo-Cap EC-1000 Capillary Columns<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

15m 0.45mm 1.00µm 40–250°C 19648<br />

0.53mm 1.20µm 40–250°C 19684<br />

30m 0.25mm 0.25µm 40–250°C 19686<br />

0.32mm 0.25µm 40–250°C 19685<br />

0.53mm 1.00µm 40–250°C 19692<br />

0.53mm 1.20µm 40–250°C 19688<br />

best<br />

value<br />

Econo-Cap EC-1000 Six-Pack Capillary Columns<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

30m 0.25mm 0.25µm 40–250°C 196866<br />

0.32mm 0.25µm 40–250°C 196856<br />

0.53mm 1.20µm 40–250°C 196886<br />

www.discoverysciences.com<br />

225


gas chromatography<br />

Heliflex ® AT -624<br />

premium<br />

• Specially tested for EPA Method 624<br />

• Similar to DB-1301, Rtx ® -1301,<br />

Rtx ® -624, HP-1301, HP-624, DB-624,<br />

007-624, 007-1301, SPB-1301, SPB-624, ZB-624<br />

Heliflex ® AT -225<br />

• Similar to DB-225, HP-225,<br />

Rtx ® -225, OV-225, RSL-500, 007-225,<br />

CP-Sil 43CB, BP-225, PE-225<br />

premium<br />

Heliflex ® AT-624 Specifications<br />

Phase:<br />

6% Cyanopropylphenyl-94% Methylpolysiloxane<br />

Polarity: Intermediate Polarity<br />

USP Code: G43<br />

Ideal For: EPA Methods 524, 601, 602, 624, 8240 and 8260, and<br />

Solvent Analysis<br />

Heliflex ® AT-225 Specifications<br />

Phase:<br />

(50% Cyanopropylphenyl)-50% Methylpolysiloxane<br />

Polarity: Mid to High Polarity<br />

USP Code: G19<br />

Ideal For: Carbohydrates and Solvents<br />

gc columns | capillary<br />

Heliflex ® AT-624 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

30m 0.25mm 1.40µm -20–260°C 13754<br />

0.32mm 1.80µm -20–260°C 13756<br />

0.32mm 3.00µm -20–260°C 13780<br />

0.53mm 3.00µm -20–260°C 16889<br />

60m 0.25mm 1.40µm -20–260°C 13503<br />

0.32mm 1.80µm -20–260°C 13799<br />

0.53mm 3.00µm -20–260°C 13800<br />

75m 0.53mm 3.00µm -20–260°C 13937<br />

EPA Method 602 — Purgeable Aromatics<br />

1<br />

2<br />

3 4 5<br />

1233<br />

6 1. Benzene<br />

2. Toluene<br />

3. Chlorobenzene<br />

4. Ethylbenzene<br />

5. 1,3-Dichlorobenzene<br />

7<br />

6. 1,4-Dichlorobenzene<br />

7. 1,2-Dichlorobenzene<br />

Heliflex ® AT-225 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

15m 0.25mm 0.20µm 40–240°C 912515<br />

0.25mm 0.25µm 40–240°C 13883<br />

0.32mm 0.25µm 40–240°C 13774<br />

25m 0.25mm 0.20µm 40–240°C 912525<br />

0.53mm 1.20µm 40–220°C 915125<br />

30m 0.25mm 0.25µm 40–240°C 13773<br />

0.32mm 0.25µm 40–240°C 13775<br />

0.32mm 0.30µm 40–240°C 913230<br />

0.53mm 1.20µm 40–220°C 915130<br />

6515<br />

related products<br />

Parker Balston ® FID gas station<br />

The Parker Balston ® FID gas station combines<br />

Parker’s zero air and hydrogen generation<br />

technologies into a single unit, eliminating the<br />

inconveniences and cost of hydrogen and gas<br />

cylinders. See page 208.<br />

0 2 4 6 8 10 12 14 16 Min.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-624, 30m x 0.32mm x 1.80µm<br />

(Part No. 13756)<br />

90°C (7min hold) to 180°C at 10°C/min<br />

Helium at 1.1mL/min<br />

FID<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

226 www.discoverysciences.com


gas chromatography<br />

Heliflex ® AT -Silar-90<br />

• Designed and tested for FAME<br />

• Similar to DB-23, CP-Sil 84, Rtx ® -2330, SP-2330<br />

premium<br />

Heliflex ® AT -Silar-100<br />

• Ideal for high and low temperature separation of<br />

samples containing geometric isomers of FAMEs<br />

• Similar to CO-Sil 88, Rtx ® -2330, SP-2340<br />

premium<br />

Heliflex ® AT-Silar-90 Specifications<br />

Phase:<br />

Poly (90% bis Cyanopropyl)-10% Cyanopropyphenyl<br />

Siloxane<br />

Polarity: High Polarity<br />

USP Code: G8<br />

Ideal For: Analysis of FAMEs<br />

Heliflex ® AT-Silar-100 Specifications<br />

Phase:<br />

Poly bis Cyanopropyl<br />

Polarity: High Polarity Available<br />

USP Code: G8<br />

Ideal For: cis/trans Isomers of FAMEs, Dioxins, and Furans<br />

Heliflex ® AT-Silar-90 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

15m 0.25mm 0.20µm 0–250°C 12627<br />

0.32mm 0.20µm 0–250°C 12629<br />

30m 0.25mm 0.20µm 0–250°C 12628<br />

0.32mm 0.20µm 0–250°C 12630<br />

1<br />

2<br />

3<br />

Fatty Acid Methyl Esters<br />

4 5 10<br />

9<br />

6<br />

7 8<br />

11<br />

12<br />

1. C14:0<br />

2. C16:0<br />

3. C16:1<br />

4. C18:1<br />

5. C18:2<br />

6. C18:3<br />

7. C18:3<br />

8. C20:1<br />

9. C20:3<br />

13<br />

14<br />

2678<br />

10. C20:4<br />

11. C20:5<br />

12. C22:4<br />

13. C22:5<br />

14. C22:6<br />

Heliflex ® AT-Silar-100 Capillary Columns<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

15m 0.25mm 0.20µm 0–250°C 12631<br />

0.32mm 0.20µm 0–250°C 12633<br />

30m 0.25mm 0.20µm 0–250°C 12632<br />

0.32mm 0.20µm 0–250°C 12634<br />

1<br />

Fatty Acid Methyl Esters<br />

in Rapeseed Oil<br />

2<br />

3<br />

4 5<br />

6<br />

7<br />

8<br />

1. C14:0<br />

2. C16:0<br />

3. C18:0<br />

4. C18:1<br />

5. C18:2<br />

6. C20:0<br />

9<br />

10<br />

2679<br />

7. C20:1<br />

8. C18:3<br />

9. C22:0<br />

10. C22:1<br />

gc columns | capillary<br />

0<br />

2 4 6 8 10 12 14 16 18 20 22 24 26 Min.<br />

0<br />

2 4 6 8 10 12 Min.<br />

Column: Heliflex ® AT-Silar-90, 30m x 0.25mm x 0.20µm<br />

(Part No. 24019)<br />

Temp: 200°C<br />

Carrier Gas: Helium at 20cm/sec<br />

Detector: FID<br />

Column: Heliflex ® AT-Silar-100, 30m x 0.25mm x 0.20µm<br />

(Part No. 24022)<br />

Temp: 190°C<br />

Carrier Gas: Helium at 20cm/sec<br />

Detector: FID<br />

tech tip<br />

Tips for Heliflex ® AT-Silar-90 and Silar-100<br />

Silar-90 and Silar-100 are more susceptible to damage by<br />

oxygen, moisture, and HCL than other silicone phases. Avoid<br />

solvents such as water and methanol when using on-column<br />

injection techniques. Columns should not be rinsed.<br />

more info<br />

For Capillary GC Applications, see the GC Applications Section,<br />

pages 462–493.<br />

www.discoverysciences.com<br />

227


gas chromatography<br />

Heliflex ® AT -Amino Acid<br />

• Separates all 20 essential amino acids<br />

Heliflex ® AT-Amino Acid Specifications<br />

Phase:<br />

Proprietary<br />

Polarity: Intermediate<br />

USP Code: n/a<br />

Ideal For: Amino Acids<br />

premium<br />

Heliflex ® Drug<br />

Analysis Capillaries<br />

• No derivatization of sample necessary<br />

• Specially tested for drugs<br />

premium<br />

Drug One is a non-polar column that will elute drugs in<br />

the same order as an OV-1 or OV-101 packed column.<br />

Drug Two is a moderately polar column that will give a<br />

retention order similar to OV-17. Drug Three is a special<br />

phase formulated for the analysis of anticonvulsants.<br />

gc columns | capillary<br />

Heliflex ® AT-Amino Acid Capillary Column<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

25m 0.53mm 1.20µm -20–350°C 16864<br />

N(O,S)-Heptafluorobutyl-isobutyl Esters of Amino<br />

Acids from Soy Protein Hydrolysate<br />

1. Alanine<br />

2. Glycine<br />

3. Valine<br />

4. Threonine<br />

5. Serine<br />

6. Leucine<br />

1<br />

2<br />

3<br />

4<br />

7. Isoleucine<br />

8. Proline<br />

9. Cystine<br />

10. Methionine<br />

11. Aspartic Acid<br />

12. Phenylalanine<br />

6<br />

5<br />

7<br />

8<br />

9<br />

10<br />

13. Glutamic Acid<br />

14. Lysine<br />

15. Tyrosine<br />

16. Arginine<br />

17. Histidine<br />

18. Tryptophan<br />

0 5 10 15 20 25 30 35 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17 18<br />

1288<br />

Heliflex ® AT-Amino Acid, 25m x 0.53mm x 1.20µm<br />

(Part No. 16864)<br />

80°C (2min hold) to 230°C at 4°C/min<br />

Helium at 10mL/min<br />

FID<br />

Drug Specifications<br />

Phase:<br />

Proprietary<br />

Polarity: Drug 1—Non-Polar, Drug 2—Intermediate Polarity,<br />

Drug 3—Polar<br />

Temp. Limit: 330°C Isothermal/350°C Programmed<br />

USP Code: n/a<br />

Ideal For: Drug Analysis<br />

Heliflex ® Drug Capillary Columns<br />

Length Coating i.d. Film Temp. Limits* Part No.<br />

10m Drug One 0.53mm 1.20µm 330/350°C 16844<br />

Drug Two 0.53mm 1.20µm 330/350°C 16845<br />

Drug Three 0.53mm 1.20µm 330/350°C 16847<br />

30m Drug One 0.25mm 0.25µm 330/350°C 13745<br />

Drug Two 0.25mm 0.25µm 330/350°C 13746<br />

Drug One 0.32mm 0.25µm 330/350°C 13748<br />

Drug Two 0.32mm 0.25µm 330/350°C 13750<br />

*Isothermal/Temp. program.<br />

0<br />

4<br />

1<br />

3<br />

2<br />

8<br />

7<br />

5<br />

6<br />

10<br />

9<br />

4 8 12<br />

11 12 13<br />

Drug Mixture<br />

16 Min.<br />

0042<br />

1. Methylenedioxymethamphetamine<br />

(MDMA)<br />

2. Benzocaine<br />

3. Meperidine<br />

4. Phencyclidine (PCP)<br />

5. Caffeine<br />

6. Procaine<br />

7. Mepivacaine<br />

8. Methadone<br />

9. Atropine<br />

10. Cocaine<br />

11. Oxazepam<br />

12. Codeine<br />

13. Diazepam<br />

more info<br />

For Capillary GC Applications, see the GC Applications Section,<br />

pages 462–493.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® Drug Two, 30m x 0.25mm x 0.25µm<br />

(Part No. 13746)<br />

230°C to 250°C at 5°C/min<br />

Helium at 0.64mL/min<br />

FID<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

tech tip<br />

Temperature limits<br />

Our GC capillary columns are temperature rated. In some cases,<br />

we list two maximum operating temperatures, the lower one is<br />

for isothermal condition and the higher one for temperatureprogrammed<br />

condition.<br />

228 www.discoverysciences.com


gas chromatography<br />

Heliflex ® USP 467<br />

Capillary Kits<br />

• Tested for organic volatile impurities<br />

• Kits for Method I and V for Method 467<br />

• Guard columns plus connector<br />

premium<br />

USP Method 467 deals with the determination of organic<br />

volatile impurities in pharmaceuticals, which results from<br />

solvents commonly used in the manufacturing process.<br />

Method I Kit Contains:<br />

AT-5, (USP G27) 30m x 0.53mm x 5.00µm; 5 x Universal<br />

FSOT Connectors; and 5 x 5m Deactivated Guard Columns<br />

(0.53mm i.d.).<br />

Method V Kit Contains:<br />

AT-624, (USP G43) 30m x 0.53mm x 3.00µm; 5 x Universal<br />

FSOT Connectors; and 5 x 5m Deactivated Guard Columns<br />

(0.53mm i.d.).<br />

Method I Kit Specifications<br />

Phase:<br />

(5% Phenyl)-95% Methylpolysiloxane<br />

Polarity: Non-Polar<br />

Temp. Limit: -60–350°C<br />

USP Code: G27<br />

Ideal For: Drug Analysis<br />

3<br />

5<br />

USP 467 - Trace Volatiles<br />

8<br />

1797<br />

1. Ethylene Oxide<br />

2. Impurity<br />

3. Methylene Chloride<br />

4. Chloroform<br />

5. Benzene<br />

6. Trichloroethylene<br />

7. 1,4-Dioxane<br />

8. Dimethyl Sulfoxide<br />

5 6<br />

Method V Kit Specifications<br />

Phase:<br />

(6% Cyanopropylphenyl)-94% Methylpolysiloxane<br />

Polarity: Intermediate<br />

Temp. Limit: 20–260°C<br />

USP Code: G43<br />

Ideal For: Drug Analysis<br />

USP 467 - Method V<br />

1866<br />

4<br />

1. Ethylene Oxide<br />

2. Methylene Chloride<br />

2<br />

3. Chloroform<br />

4. Benzene<br />

5. Trichloroethylene<br />

6. 1,4-Dioxane<br />

gc columns | capillary<br />

7<br />

1<br />

12<br />

4<br />

6<br />

3<br />

0 3 6 9 12 15 18 Min.<br />

Column: Heliflex ® AT-5, 30m x 0.53mm x 5.00µm<br />

(Part No. 16859)<br />

Temp:<br />

35°C (5 min hold) to 175°C at 8°C/min<br />

Carrier Gas: Helium at 35cm/sec<br />

Detector: FID at 260°C<br />

0 4 8 12 16 20 Min.<br />

Column: Heliflex ® AT-624, 30m x 0.53mm x 3.00µm<br />

(Part No. 16889)<br />

Temp: 40°C<br />

Carrier Gas: Helium at 35cm/sec<br />

Detector: FID<br />

more info<br />

For more information on Pharmaceutical analysis,<br />

request brochure #470.<br />

USP 467 Capillary Kits<br />

Description<br />

Part No.<br />

Capillary Kits<br />

USP 467/Method I Capillary Kit 13963<br />

USP 467/Method V Capillary Kit 13971<br />

Replacement Components<br />

AT-5, 30m x 0.53mm x 5.0µm 16859<br />

AT-624, 30m x 0.53mm x 3.0µm 16889<br />

Universal FSOT Connectors, 5/pk 20400<br />

Deactivated Guard Columns, 5m x 0.53mm, 5/pk 13990<br />

www.discoverysciences.com<br />

229


gas chromatography<br />

Heliflex ® AT -Pesticide<br />

• Unique selectivity for pesticide confirmation<br />

• Pretested with pesticide mix<br />

premium<br />

Heliflex ® AT -502.2<br />

• Separates early eluting gases at above<br />

ambient temperature<br />

• Useful for volatile organics analysis, including EPA<br />

Methods 502.2, 524.2, 8260<br />

premium<br />

Heliflex ® AT-Pesticide Specifications<br />

Phase:<br />

Proprietary<br />

Polarity: Intermediate<br />

USP Code: n/a<br />

Ideal For: Chlorinated Pesticides, PCBs<br />

Heliflex ® AT-502.2 Specifications<br />

Phase: Proprietary<br />

Polarity: Intermediate<br />

USP Code: n/a<br />

Ideal For: Volatile Organics and EPA Methods 502.2, 524.2, and 8260<br />

gc columns | capillary<br />

Heliflex ® AT-Pesticide Capillary Columns<br />

Temp. Limits<br />

Length i.d. Film<br />

min.–max. Part No.<br />

20m 0.53mm 0.60µm 40–240°C 16846<br />

30m 0.25mm 0.25µm 40–240°C 13662<br />

0.32mm 0.25µm 40–240°C 13744<br />

0.53mm 0.60µm 40–240°C 13969<br />

1<br />

2<br />

4<br />

6<br />

5<br />

3<br />

Chlorinated Pesticides<br />

7<br />

9 10<br />

8 11<br />

13 12<br />

14<br />

15<br />

16<br />

1. α-BHC<br />

2. γ-BHC<br />

3. β-BHC<br />

4. δ-BHC<br />

1569<br />

5. Heptachlor<br />

6. Aldrin<br />

7. Heptachlor Epoxide<br />

8. Endosulfan I<br />

9. p,p'-DDE<br />

10. Dieldrin<br />

11. Endrin<br />

12. p,p'-DDD<br />

13. Endosulfan II<br />

14. p,p'-DDT<br />

15. Endrin Aldehyde<br />

16. Endosulfan Sulfate<br />

Heliflex ® AT-502.2 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limit<br />

max.<br />

Part No.<br />

30m 0.25mm 1.40µm 270°C 13787<br />

0.32mm 1.80µm 270°C 13789<br />

0.53mm 3.00µm 270°C 13792<br />

60m 0.25mm 1.40µm 270°C 13788<br />

0.32mm 1.80µm 270°C 13790<br />

0.53mm 3.00µm 270°C 13793<br />

105m 0.32mm 1.80µm 270°C 13791<br />

0.53mm 3.00µm 270°C 13794<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

TCLP Volatiles Mix<br />

8<br />

9<br />

10<br />

2064<br />

1. Vinyl Chloride<br />

2. 1,1-Dichloroethene<br />

3. 2-Butanone<br />

4. Chloroform<br />

5. Carbon Tetrachloride<br />

6. Benzene + 1,2-Dichloroethene<br />

7. Trichloroethene<br />

8. Tetrachloroethene<br />

9. Chlorobenzene<br />

10. 1,4-Dichlorobenzene<br />

0 4 8 12 16 20 Min.<br />

0<br />

3 6 9 12 15 18 21 24 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-Pesticide, 30m x 0.25mm x 0.25µm<br />

(Part No. 13662)<br />

190°C to 240°C at 3°C/min<br />

Helium at 0.65mL/min<br />

ECD<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-502.2, 30m x 0.53mm x 3.00µm<br />

(Part No. 13792)<br />

40°C (10min hold) to 120°C at 4°C/min<br />

Helium at 22cm/sec<br />

FID<br />

more info<br />

For Capillary GC Applications, see the GC Applications Section,<br />

pages 462–493.<br />

related products<br />

Need sample prep for your pesticide<br />

analysis?<br />

Florisil ® -PR is pretested specifically<br />

chlorinated pesticides, see page 309.<br />

230 www.discoverysciences.com


gas chromatography<br />

Heliflex ® AT -2887<br />

• For simulated distillation of petroleum<br />

products<br />

premium<br />

Heliflex ® AT -Sulfur<br />

• Designed for the analysis of volatile sulfurcontaining<br />

compounds in petroleum distillates<br />

premium<br />

Heliflex ® AT-2887 Specifications<br />

Phase:<br />

100% Methylpolysiloxane<br />

Polarity: Non-Polar<br />

USP Code: n/a<br />

Ideal For: Petroleum Distillation<br />

Heliflex ® AT-Sulfur Specifications<br />

Phase:<br />

100% Methylpolysiloxane<br />

Polarity: Non-Polar<br />

USP Code: n/a<br />

Ideal For: Volatile Sulfur Compounds<br />

Heliflex ® AT-2887 Capillary Column<br />

Length i.d. Film<br />

Temp. Limit<br />

max.<br />

Part No.<br />

10m 0.53mm 1.20µm 350°C 13947<br />

Test Mix for AT-2887 41719<br />

Heliflex ® AT-Sulfur Capillary Columns<br />

Length i.d. Film<br />

Temp. Limit<br />

min.–max.<br />

Part No.<br />

30m 0.32mm 4.00µm -20–350°C 14029<br />

Heliflex ® AT -3710<br />

• For boiling range of gasoline samples<br />

Heliflex ® AT-3710 Specifications<br />

Phase:<br />

100% Methylpolysiloxane<br />

Polarity: Non-Polar<br />

USP Code: n/a<br />

Ideal For: Boiling Point of Gasoline<br />

premium<br />

Heliflex ® AT-3710 Capillary Column<br />

Length i.d. Film<br />

Temp. Limit<br />

max.<br />

Part No.<br />

15m 0.53mm 5.00µm 300°C 13949<br />

Test Mix for AT-3710 41718<br />

Heliflex ® AT -Amine<br />

• Separates underivatized amines with no tailing<br />

Heliflex ® AT-Amine Specifications<br />

Phase:<br />

Proprietary—Non-bonded<br />

Polarity: Intermediate<br />

USP Code: n/a<br />

Ideal For: Amino Acids<br />

premium<br />

Heliflex ® AT-Amine Capillary Columns<br />

Length i.d. Film<br />

Temp. Limit<br />

max.<br />

Part No.<br />

30m 0.25mm 0.25µm 200°C 13314<br />

0.32mm 0.25µm 200°C 13316<br />

0.53mm 0.25µm 200°C 13318<br />

60m 0.25mm 0.25µm 200°C 13315<br />

0.32mm 0.25µm 200°C 13317<br />

0.53mm 0.25µm 200°C 13319<br />

gc columns | capillary<br />

Heliflex ® AT -Petro<br />

• For high resolution of complex<br />

hydrocarbon mixtures<br />

premium<br />

more info<br />

For more information about Petrochemical analysis,<br />

request brochure #478.<br />

Heliflex ® AT-Petro Specifications<br />

Phase:<br />

100% Methylpolysiloxane<br />

Polarity: Non-Polar<br />

USP Code: n/a<br />

Ideal For: hydrocarbon Mixtures<br />

Heliflex ® AT-Petro Capillary Column<br />

Length i.d. Film<br />

Temp. Limit<br />

max.<br />

Part No.<br />

100m 0.25mm 0.50µm 350°C 13948<br />

more info<br />

For Capillary GC Applications, see the GC Applications Section,<br />

pages 462–493.<br />

more applications<br />

To view our complete searchable<br />

chromatogram database visit<br />

www.discoverysciences.com/chromdb/<br />

www.discoverysciences.com<br />

231


gas chromatography<br />

gc columns | capillary<br />

Alltech Column Guide to EPA Methods<br />

Alltech Guide to Capillary Columns for Environmental Analysis<br />

Method Description and Recommended Columns Comments Part No.<br />

501.3—Trihalomethanes in Drinking Water<br />

Heliflex ® AT-624, 30m x 0.53mm x 3.00µm 16889<br />

502.1—Volatile Halogenated Organics by Purge and Trap GC/ELCD<br />

Heliflex ® AT-624, 30m x 0.53mm x 3.00µm Subambient 16889<br />

Heliflex ® AT-624, 60m x 0.53mm x 3.00µm Ambient 13800<br />

502.2—Volatile Organics in Water by Purge and Trap GC/PID/ELCD<br />

Heliflex ® AT-502.2, 105m x 0.53mm x 3.00µm 13794<br />

Heliflex ® AT-624, 60m x 0.53mm x 3.00µm 13800<br />

DB-624, 75m x 0.53mm x 3.00µm 125-1374<br />

504—DBE and DBCP by Microextraction GC/ECD<br />

DX-3, 30m x 0.32mm x 0.25µm 123-6332<br />

Econo-Cap EC-1, 30m x 0.32mm x 1.00µm (Inexpensive, Batch QC’ed Column) 19660<br />

505—Organohalide Pesticides and PCBs by Microextraction and GC/ECD<br />

Heliflex ® AT-1, 30m x 0.32mm x 1.00µm Primary Column 13641<br />

DX-3, 30m x 0.32mm x 0.25µm Alternate Column 123-6332<br />

506—Phthalate and Adipate Esters in Water (GC/PID)<br />

Heliflex ® AT-1, 30m x 0.32mm x 0.25µm 13640<br />

Heliflex ® AT-5, 30m x 0.32mm x 0.25µm 13658<br />

507—Nitrogen and Phosphorus Containing Pesticides by GC/NPD<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm Primary Column 13656<br />

Econo-Cap EC-5, 30m x 0.25mm x 0.25µm (Inexpensive, Batch QC’ed Column) 19647<br />

Heliflex ® AT-1701, 30m x 0.25mm x 0.25µm Confirmation Column 13686<br />

508—Chlorinated Pesticides by GC/ECD<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm Primary Column 13656<br />

Econo-Cap EC-5, 30m x 0.25mm x 0.25µm (Inexpensive, Batch QC’ed Column) 19647<br />

Heliflex ® AT-1701, 30m x 0.25mm x 0.25µm Alternate Column 13686<br />

Heliflex ® AT-Pesticide, 30m x 0.32mm x 0.25µm 13744<br />

Heliflex ® AT-Pesticide, 30m x 0.25mm x 0.25µm 13662<br />

513—2, 3, 7, 8 Tetrachlorodibenzo-p-Dioxin<br />

DB-Dioxin, 60m x 0.25mm x 0.15µm 122-2461<br />

DB-Dioxin, 60m x 0.32mm x 0.15µm 123-2461<br />

515.1—Chlorinated Acids by GC/ECD<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm Primary Column 13656<br />

Econo-Cap EC-5 Econo-Cap, 30m x 0.25mm x 0.25µm (Inexpensive, batch QC’ed column) 19647<br />

Heliflex ® AT-1701, 30m x 0.25mm x 0.25µm Confirmation Column 13686<br />

524.2—Purgeables by Purge and Trap GC/MS<br />

Heliflex ® AT-624, 30m x 0.53mm x 3.00µm Subambient (10°C) 16889<br />

Heliflex ® AT-624, 60m x 0.53mm x 3.00µm Ambient 13800<br />

Heliflex ® AT-5, 30m x 0.32mm x 1.00µm Subambient, Cryofocusing 13659<br />

Heliflex ® AT-5, 30m x 0.25mm x 1.00µm Subambient, Cryofocusing 13657<br />

525—Organic Compounds in Water by Liquid-Solid Extraction and Capillary GC/MS<br />

Heliflex ® AT-5ms, 30m x 0.32mm x 0.25µm 15894<br />

Heliflex ® AT-5ms, 30m x 0.25mm x 0.25µm 15807<br />

548—Endothall in Drinking Water<br />

Heliflex ® AT-1, 30m x 0.25mm x 0.25µm 13638<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm 13656<br />

551—Chlorination Disinfection By-products and Chlorinated Solvents in Drinking Water<br />

Heliflex ® AT-1, 30m x 0.32mm x 1.00µm 13641<br />

Heliflex ® AT-210, 30m x 0.32mm x 0.50µm 13727<br />

Econo-Cap EC-1, 30m x 0.32mm x 1.00µm (Inexpensive, Batch QC’ed Column) 19660<br />

552.1—Haloacetic Acids in Drinking Water<br />

Heliflex ® AT-1701, 30m x 0.32mm x 0.25µm 13690<br />

Heliflex ® AT-210, 30m x 0.32mm x 0.50µm 13727<br />

556.1—Carbonyl Compounds in Drinking Water<br />

Heliflex ® AT-5, 10m x 0.10mm x 0.10µm Fast GC 14438<br />

Heliflex ® AT-1701, 10m x 0.10mm x 0.10µm Fast GC 14439<br />

232 www.discoverysciences.com


gas chromatography<br />

Alltech Column Guide to EPA Methods (continued)<br />

Alltech Guide to Capillary Columns for Environmental Analysis (continued)<br />

Method Description and Recommended Columns Comments Part No.<br />

601—Purgeable Halocarbons by Purge and Trap ELCD<br />

Heliflex ® AT-624, 30m x 0.53mm x 3.00µm Subambient 16889<br />

Heliflex ® AT-624, 60m x 0.53mm x 3.00µm Ambient 13800<br />

602—Purgeable Aromatics by Purge and Trap GC/PID<br />

Heliflex ® AT-624, 30m x 0.53mm x 3.00µm 16889<br />

Heliflex ® AT-WAX, 30m x 0.53mm x 2.50µm Plus xylenes 16885<br />

Econo-Cap EC-WAX, 30m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19659<br />

603—Acrolein and Acrylonitrile by GC/FID<br />

Heliflex ® AT-624, 30m x 0.53mm x 3.00µm 16889<br />

604—Phenols by GC/FID and GC/ECD<br />

Heliflex ® AT-5, 30m x 0.53mm x 1.20µm 955130<br />

Econo-Cap EC-5, 30m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19657<br />

Heliflex ® AT-5, 30m x 0.32mm x 0.25µm 13658<br />

Econo-Cap EC-5, 30m x 0.32mm x 0.25µm (Inexpensive, Batch QC’ed Column) 19646<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm 13656<br />

Econo-Cap EC-5, 30m x 0.25mm x 0.25µm (Inexpensive, Batch QC’ed Column) 19647<br />

606—Phthalate Esters by GC/ECD<br />

Heliflex ® AT-5, 15m x 0.53mm x 1.20µm 955115<br />

Econo-Cap EC-5, 15m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19645<br />

607—Nitrosamines<br />

Heliflex ® AT-5, 15m x 0.53mm x 1.20µm 955115<br />

Econo-Cap EC-5, 15m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19645<br />

608—Organochlorine Pesticides and PCBs by GC/ECD<br />

Heliflex ® AT-Pesticide, 20m x 0.53mm x 0.60µm 16846<br />

Heliflex ® AT-Pesticide, 30m x 0.32mm x 0.25µm 13744<br />

Heliflex ® AT-Pesticide, 30m x 0.25mm x 0.25µm 13662<br />

609—Nitroaromatics and Isophorone by GC/FID and GC/ECD<br />

Heliflex ® AT-5, 15m x 0.53mm x 1.20µm (Capillary GC) 955115<br />

610—Polynuclear Aromatic Hydrocarbons by GC/FID<br />

Heliflex ® AT-5, 30m x 0.53mm x 1.20µm 955130<br />

Econo-Cap EC-5, 30m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19657<br />

Heliflex ® AT-5, 30m x 0.32mm x 0.25µm 13658<br />

610—Polynuclear Aromatic Hydrocarbons by HPLC and GC/FID<br />

Heliflex ® AT-5, 30m x 0.32mm x 0.25µm 13658<br />

Econo-Cap EC-5, 30m x 0.32mm x 0.25µm (Inexpensive, Batch QC’ed Column) 19646<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm 13656<br />

Econo-Cap EC-5, 30m x 0.25mm x 0.25µm (Inexpensive, Batch QC’ed Column) 19647<br />

611—Haloethers by GC/HSD<br />

Heliflex ® AT-5, 15m x 0.53mm x 1.20µm 955115<br />

Econo-Cap EC-5, 15m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19645<br />

612—Chlorinated Hydrocarbons by GC/ECD<br />

Heliflex ® AT-5, 15m x 0.53mm x 1.20µm 955115<br />

Econo-Cap EC-5, 15m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19645<br />

615—Chlorinated Herbicides by GC/ECD/ELCD<br />

Heliflex ® AT-1, 30m x 0.32mm x 0.25µm 13640<br />

Econo-Cap EC-1, 30m x 0.32mm x 0.25µm (Inexpensive, Batch QC’ed Column) 19651<br />

619—Triazine Herbicides<br />

Heliflex ® AT-50, 30m x 0.53mm x 1.00µm 13878<br />

624—Purgeables by Purge and Trap GC/MS<br />

Heliflex ® AT-624, 30m x 0.53mm x 3.00µm Subambient (10°C) 16889<br />

Heliflex ® AT-624, 60m x 0.53mm x 3.00µm Ambient 13800<br />

Heliflex ® AT-5, 30m x 0.32mm x 1.00µm Subambient, Cryofocusing 13659<br />

Heliflex ® AT-5, 30m x 0.25mm x 1.00µm Subambient, Cryofocusing 13657<br />

625—Base/Neutral and Acids by GC/MS See Method 8270 —<br />

680—Pesticides and PCBs in Water and Soil/Sediment by GC/MS<br />

Heliflex ® AT-5ms, 30m x 0.32mm x 0.25µm 15894<br />

8011- EDB and DBCP by Microextraction Using GC<br />

Heliflex ® AT-1, 30m x 0.32mm x 0.25µm 13640<br />

gc columns | capillary<br />

www.discoverysciences.com<br />

233


gas chromatography<br />

gc columns | capillary<br />

Alltech Column Guide to EPA Methods (continued)<br />

Alltech Guide to Capillary Columns for Environmental Analysis (continued)<br />

Method Description and Recommended Columns Comments Part No.<br />

8015—Nonhalogenated Volatile Organics<br />

Heliflex ® AT-WAX, 30m x 0.53mm x 1.00µm 13907<br />

Heliflex ® AT-5, 30m x 0.53mm x 1.50µm 13909<br />

8021—Halogenated Volatiles Using GC/PID/ELCD<br />

Heliflex ® AT-20, 60m x 0.53mm x 1.20µm 13933<br />

8032—Acrylamide by GC/ECD<br />

Heliflex ® AT-1000, 15m x 0.53mm x 1.20µm 975115<br />

8033—Acetonitrile by GC/NPD<br />

Heliflex ® AT-WAX, 15m x 0.53mm x 1.00µm 13904<br />

8041—Phenols by GC/FID/(ECD)<br />

Heliflex ® AT-5, 30m x 0.53mm x 1.50µm 13909<br />

Heliflex ® AT-1701, 30m x 0.53mm x 1.00µm 13795<br />

8070—Nitrosamines<br />

Heliflex ® AT-5, 15m x 0.53mm x 1.20µm 955115<br />

Econo-Cap EC-5, 15m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19645<br />

8081—Organochlorine Pesticides by GC/ECD<br />

Heliflex ® AT-5, 30m x 0.25mm x 1.00µm 13657<br />

Heliflex ® AT-35, 30m x 0.25mm x 1.00µm 13796<br />

Heliflex ® AT-35, 30m x 0.53mm x 0.50µm 13797<br />

Heliflex ® AT-1701, 30m x 0.53mm x 1.00µm 13795<br />

Heliflex ® AT-5, 30m x 0.53mm x 1.50µm 13909<br />

Heliflex ® AT-Pesticide, 30m x 0.53mm x 0.60µm 13969<br />

8082—Polychlorinated Biphenyls (PCBs) by GC/ECD or GC/ELCD<br />

Heliflex ® AT-5, 30m x 0.25mm x 1.00µm 13657<br />

Heliflex ® AT-35, 30m x 0.25mm x 1.00µm 13796<br />

Heliflex ® AT-35, 30m x 0.53mm x 0.50µm 13797<br />

Heliflex ® AT-1701, 30m x 0.53mm x 1.00µm 13795<br />

Heliflex ® AT-5, 30m x 0.53mm x 1.50µm 13909<br />

Heliflex ® AT-Pesticide, 30m x 0.53mm x 0.60µm 13969<br />

8091—Nitroaromatics and Cyclic Ketones by GC/ECD or GC/NPD<br />

Heliflex ® AT-5, 30m x 0.53mm x 1.50µm 13909<br />

Heliflex ® AT-1701, 30m x 0.53mm x 1.00µm 13795<br />

8100—Polynuclear Aromatic Hydrocarbons by GC/FID<br />

Heliflex ® AT-5, 30m x 0.53mm x 1.20µm 955130<br />

Econo-Cap EC-5, 30m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19657<br />

Heliflex ® AT-5, 30m x 0.32mm x 0.25µm 13658<br />

Econo-Cap EC-5, 30m x 0.32mm x 0.25µm (Inexpensive, Batch QC’ed Column) 19646<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm 13656<br />

Econo-Cap EC-5, 30m x 0.25mm x 0.25µm (Inexpensive, Batch QC’ed Column) 19647<br />

8111—Haloethers by GC/ECD<br />

Heliflex ® AT-5, 30m x 0.53mm x 1.50µm 13909<br />

Heliflex ® AT-1701, 30m x 0.53mm x 1.20µm 13830<br />

8141—Organophosphorus Pesticides by GC/NPD/FPD/ELCD<br />

Heliflex ® AT-210, 15m x 0.53mm x 1.20µm Column 1 985115<br />

Heliflex ® AT-5, 15m x 0.53mm x 1.20µm Column 2 955115<br />

Econo-Cap EC-5, 15m x 0.53mm x 1.20µm (Inexpensive, Batch QC’ed Column) 19645<br />

8151—Chlorinated Herbicides by GC/ECD Using Methylation and Pentafluorobenzylation Derivatization<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm 13656<br />

Heliflex ® AT-5, 30m x 0.32mm x 1.00µm 13659<br />

Heliflex ® AT-35, 30m x 0.25mm x 0.25µm 13642<br />

Heliflex ® AT-1701, 30m x 0.25mm x 0.25µm 13686<br />

Heliflex ® AT-1701, 30m x 0.53mm x 1.00µm 13795<br />

Heliflex ® AT-Pesticide, 30m x 0.53mm x 0.60µm 13969<br />

8260—Volatile Organics by GC/MS: Capillary Column Technique<br />

Heliflex ® AT-624, 30m x 0.53mm x 3.00µm Subambient (10°C) 16889<br />

Heliflex ® AT-624, 60m x 0.53mm x 3.00µm Ambient 13800<br />

Heliflex ® AT-5, 30m x 0.32mm x 1.00µm Subambient, Cryofocusing 13659<br />

Heliflex ® AT-5, 30m x 0.25mm x 1.00µm Subambient, Cryofocusing 13657<br />

Heliflex ® AT-502.2, 60m x 0.53mm x 3.00µm Ambient 13793<br />

Heliflex ® AT-502.2, 105m x 0.53mm x 3.00µm Ambient 13794<br />

234 www.discoverysciences.com


gas chromatography<br />

Astec Chiraldex ® GC Capillary Columns<br />

• Resolve aromatic and nonaromatic enantiomers<br />

• Pure cyclodextrin derivative coating<br />

• No racemization of chiral stationary phase at elevated<br />

temperatures<br />

Chiraldex ® capillaries are based on derivatized cyclodextrins,<br />

which are chiral in nature formed by the α-1,4 linkage of<br />

glucose units into toroidal shaped structures. The enzyme<br />

cyclodextrin glucosyl transferance (CGT) cleaves partially<br />

digested starch and links the glucose units into predominantly<br />

three forms, referred to as alpha, beta, and gamma; 6, 7,<br />

and 8 glucose units, respectively. These cyclodextrins are<br />

thermally stable, highly crystalline and virtually insoluble in<br />

most organic solvents. Using the three forms of cyclodextrin,<br />

Astec has manufactured derivatives that exhibit properties<br />

allowing them to be used as GC phases. They are:<br />

– Permethylated Hydroxypropyl (PH)<br />

– Dialkylated (DA)<br />

– Trifluoroacetylated (TA)<br />

– Propionylated (PN)<br />

– Butyrylated (BP)<br />

– Permethylated (PM)<br />

– Dimethylated (DM)<br />

– Dipropionyl (DP)<br />

The prefix A, B, G describes the cyclodextrins alpha,<br />

beta, and gamma, respectively. The suffix describes the<br />

nature of the derivatization i.e., G-TA refers to Gamma<br />

Trifluororacetylated phase.<br />

The most striking characteristic of these phases is that they<br />

separate nonaromatic enantiomers including saturated<br />

alcohols, amines, carboxylic acids, epoxides, diols, polyols,<br />

cyclic, bicyclic, heterocyclic compounds, lactones, amino<br />

alcohols, amino acids, halohydrocarbons, α-halocarboxylic<br />

esters, pyrans, and furans. Little functionality is required for<br />

chiral recognition (Table 1). Also, there can be reversals of<br />

elution order from one series to the next as well as from one<br />

cavity size (beta) to another (gamma). The acylating reagent<br />

also can contribute to stereo-selectivity.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

Table 1—General Classes of Compounds Separated on Chiraldex Capillary Columns<br />

Chiraldex ® A-PH: Smaller linear and saturated amines, alcohols, carboxylic acids, and epoxides<br />

Chiraldex ® B-PH: Most structural types of compounds including linear and cyclic amines and alcohols, carboxylic acids, lactones, amino alcohols, sugars,<br />

bicyclics, epoxides, haloalkanes, and more<br />

Chiraldex ® G-PH: Cyclic and bicyclic diols and other larger compounds including steroids and carbohydrates<br />

Chiraldex ® A-DA: Smaller cyclic amines, alcohols, and epoxides (Inquire regarding availability)<br />

Chiraldex ® B-DA: Nitrogen heterocyclics, heterocyclics, some bicyclics, and epoxides, lactones, aromatic amines, sugars, amino acid derivatives<br />

Chiraldex ® G-DA: Aromatic amines containing 2 or more rings, large cyclic diols, some heterocyclics, multi-ring compounds or compounds with bulky<br />

substituents<br />

Chiraldex ® A-TA: Smaller alcohols, amino alcohols, amino alkanes, and diols<br />

Chiraldex ® B-TA: Broad range alkyl alcohols, halo acid esters, amino alkanes, halocycloalkanes, certain lactones, diols, alkyl halides, furan and pyran<br />

derivatives<br />

Chiraldex ® G-TA: >350 pairs chiral alcohols, diols, polyols, hydrocarbons, lactones, amine alcohols, halocarboxylic acid esters, homologous series, furan<br />

and pyran derivatives, epoxides, glycidyl analogs, and haloepihydrins<br />

Chiraldex ® G-PN: Epoxides, higher alcohols >C4, lactones<br />

Chiraldex ® G-BP: Amino acids, certain primary amines and furans<br />

Chiraldex ® G-DM: Selectivity similar to PM and PH, but with shorter retention times, and greater resolution. Especially applicable to aliphatic, olefenic, and<br />

aromatic enantiomers<br />

Chiraldex ® B-PM: Acids, alcohols, barbitals, diols, epoxides, esters, hydrocarbons, ketones, lactones, and terpenes<br />

Chiraldex ® B-DM: Selectivity similar to PM and PH, but with shorter retention times, and greater resolution. Especially applicable to aliphatic, olefenic, and<br />

aromatic enantiomers<br />

Chiraldex ® B-DP: Aromatic and aliphatic amines and some aliphatic and aromatic esters<br />

Chiraldex ® G-DP: Aromatic and aliphatic amines and some aliphatic and aromatic esters<br />

gc columns | capillary<br />

www.discoverysciences.com<br />

235


gas chromatography<br />

gc columns | capillary<br />

Astec Chiraldex ® GC Capillary Columns<br />

Chiraldex ® Capillary Columns<br />

Phase Length i.d. Film Temp. Limits* Part No.<br />

B-PM 30m 0.25mm 0.25µm 230/250°C 4711<br />

50m 0.25mm 0.25µm 230/250°C 4713<br />

A-TA 10m 0.25mm 0.125µm 180/180°C 4123<br />

20m 0.25mm 0.125µm 180/180°C 4125<br />

30m 0.25mm 0.125µm 180/180°C 4127<br />

40m 0.25mm 0.125µm 180/180°C 4405<br />

50m 0.25mm 0.125µm 180/180°C 4635<br />

B-TA 10m 0.25mm 0.125µm 180/180°C 4129<br />

20m 0.25mm 0.125µm 180/180°C 4131<br />

30m 0.25mm 0.125µm 180/180°C 4133<br />

40m 0.25mm 0.125µm 180/180°C 4407<br />

50m 0.25mm 0.125µm 180/180°C 4637<br />

G-TA 10m 0.25mm 0.125µm 180/180°C 4135<br />

20m 0.25mm 0.125µm 180/180°C 4137<br />

30m 0.25mm 0.125µm 180/180°C 4139<br />

40m 0.25mm 0.125µm 180/180°C 4409<br />

50m 0.25mm 0.125µm 180/180°C 4639<br />

A-PH 10m 0.25mm 0.125µm 200/220°C 4073<br />

20m 0.25mm 0.125µm 200/220°C 4088<br />

30m 0.25mm 0.125µm 200/220°C 4089<br />

40m 0.25mm 0.125µm 200/220°C 4393<br />

50m 0.25mm 0.125µm 200/220°C 4197<br />

B-PH 10m 0.25mm 0.125µm 200/220°C 4090<br />

20m 0.25mm 0.125µm 200/220°C 4092<br />

30m 0.25mm 0.125µm 200/220°C 4094<br />

40m 0.25mm 0.125µm 200/220°C 4395<br />

50m 0.25mm 0.125µm 200/220°C 4199<br />

G-PH 10m 0.25mm 0.125µm 200/220°C 4096<br />

20m 0.25mm 0.125µm 200/220°C 4098<br />

30m 0.25mm 0.125µm 200/220°C 4101<br />

40m 0.25mm 0.125µm 200/220°C 4397<br />

50m 0.25mm 0.125µm 200/220°C 4202<br />

*Isothermal/Temp. program.<br />

Chiraldex ® GC Kits<br />

Chiraldex ® 3 column kits include 1 each of any three columns<br />

of the same i.d. and length at an economical price. We<br />

recommend as a starter kit for the broadest range<br />

of applications a Chiraldex ® -30 Kit including 1 each of<br />

B-DA, BDM, G-TA. Please note that Chiraldex ® B-PM is<br />

not included in the Chiraldex ® kits.<br />

Chiraldex ® GC Kits<br />

Phase Length i.d. Part No.<br />

Chiraldex ® -10 Kit 10m 0.25mm 4207<br />

Chiraldex ® -20 Kit 20m 0.25mm 4209<br />

Chiraldex ® -30 Kit 30m 0.25mm 4211<br />

Chiraldex ® -40 Kit 40m 0.25mm 4608<br />

Chiraldex ® -50 Kit 50m 0.25mm 4634<br />

Chiraldex ® Capillary Columns<br />

Phase Length i.d. Film Temp. Limits* Part No.<br />

A-DA 10m 0.25mm 0.125µm 200/220°C 4104<br />

20m 0.25mm 0.125µm 200/220°C 4107<br />

30m 0.25mm 0.125µm 200/220°C 4109<br />

40m 0.25mm 0.125µm 200/220°C 4399<br />

50m 0.25mm 0.125µm 200/220°C 4614<br />

B-DA 10m 0.25mm 0.125µm 200/220°C 4111<br />

20m 0.25mm 0.125µm 200/220°C 4113<br />

30m 0.25mm 0.125µm 200/220°C 4115<br />

40m 0.25mm 0.125µm 200/220°C 4401<br />

50m 0.25mm 0.125µm 200/220°C 4626<br />

G-DA 10m 0.25mm 0.125µm 200/220°C 4117<br />

20m 0.25mm 0.125µm 200/220°C 4119<br />

30m 0.25mm 0.125µm 200/220°C 4121<br />

40m 0.25mm 0.125µm 200/220°C 4403<br />

50m 0.25mm 0.125µm 200/220°C 4627<br />

G-PN 10m 0.25mm 0.125µm 200/220°C 4660<br />

20m 0.25mm 0.125µm 200/220°C 4664<br />

30m 0.25mm 0.125µm 200/220°C 4668<br />

40m 0.25mm 0.125µm 200/220°C 4672<br />

50m 0.25mm 0.125µm 200/220°C 4676<br />

G-BP 10m 0.25mm 0.125µm 200/220°C 4662<br />

20m 0.25mm 0.125µm 200/220°C 4680<br />

30m 0.25mm 0.125µm 200/220°C 4670<br />

40m 0.25mm 0.125µm 200/220°C 4674<br />

50m 0.25mm 0.125µm 200/220°C 4678<br />

G-DM 10m 0.25mm 0.25µm 230/250°C 5550<br />

20m 0.25mm 0.25µm 230/250°C 5551<br />

30m 0.25mm 0.25µm 230/250°C 5552<br />

40m 0.25mm 0.25µm 230/250°C 5599<br />

50m 0.25mm 0.25µm 230/250°C 5688<br />

B-DM 10m 0.25mm 0.12µm 230/250°C 4718<br />

20m 0.25mm 0.12µm 230/250°C 4719<br />

30m 0.25mm 0.12µm 230/250°C 4727<br />

40m 0.25mm 0.12µm 230/250°C 4728<br />

50m 0.25mm 0.12µm 230/250°C 4729<br />

B-DP 10m 0.25mm 0.125µm 200/220°C 41159<br />

20m 0.25mm 0.125µm 200/220°C 41160<br />

30m 0.25mm 0.125µm 200/220°C 41193<br />

40m 0.25mm 0.125µm 200/220°C 41165<br />

50m 0.25mm 0.125µm 200/220°C 41166<br />

G-DP 10m 0.25mm 0.125µm 200/220°C 41173<br />

20m 0.25mm 0.125µm 200/220°C 41174<br />

30m 0.25mm 0.125µm 200/220°C 41175<br />

40m 0.25mm 0.125µm 200/220°C 41176<br />

50m 0.25mm 0.125µm 200/220°C 41177<br />

*Isothermal/Temp. program.<br />

tech tip<br />

Temperature Limits<br />

Our GC capillary columns are temperature rated. In some cases,<br />

we list two maximum operating temperatures, the lower one is<br />

for isothermal condition and the higher one for temperatureprogrammed<br />

condition.<br />

236 www.discoverysciences.com


gas chromatography<br />

SGE ® BPX Capillary Columns<br />

• Extended temperature range<br />

• Low bleed ideal for GC/MS applications<br />

SGE ® uses silphenylene-siloxane chemistry to manufacture<br />

BPX stationary phases, resulting in extremely low bleed,<br />

thermally stable capillary columns.<br />

BPX Specifications<br />

Phase Phase Composition<br />

BPX1-SimD<br />

100% Methylpolysiloxane<br />

BPX5<br />

5% Phenyl, 95% Methylpolysiloxane<br />

BPX35<br />

35% Phenyl, 65% Methylpolysiloxane<br />

BPX50<br />

50% Phenyl, 50% Methylpolysiloxane<br />

BPX70<br />

70% Cyanopropyl<br />

BPX90<br />

90% Cyanopropyl Polysilphenylene-siloxane<br />

BPX 608<br />

35% Phenyl Polysilphenylene-siloxane<br />

BPX Volatiles<br />

Cyanopropylphenyl Polysiloxane<br />

BPX1-SimD Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

5m 0.53mm 0.1µm 30–430°C 54800*<br />

10m 0.53mm 0.9µm 30–400°C 54801**<br />

0.53mm 2.65µm 30–370°C 54802**<br />

*Aluminum Clad. **Polyimide Clad.<br />

BPX5 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

15m 0.25mm 0.25µm -40–360/370°C 54103<br />

0.25mm 1.00µm -40–360/370°C 54121<br />

0.32mm 0.25µm -40–360/370°C 54144<br />

0.32mm 1.00µm -40–360/370°C 54152<br />

0.53mm 1.00µm -40–360/370°C 54147<br />

0.53mm 3.00µm -40–350/360°C 54159<br />

30m 0.25mm 0.25µm -40–360/370°C 54101<br />

0.25mm 0.50µm -40–360/370°C 541025<br />

0.25mm 1.00µm -40–360/370°C 54122<br />

0.32mm 0.25µm -40–360/370°C 54145<br />

0.32mm 0.50µm -40–360/370°C 541205<br />

0.32mm 1.00µm -40–360/370°C 54153<br />

0.53mm 0.50µm -40–360/370°C 541345<br />

0.53mm 1.00µm -40–360/370°C 54148<br />

0.53mm 1.50µm -40–360/370°C 541348<br />

0.53mm 3.00µm -40–350/360°C 54160<br />

60m 0.25mm 0.25µm -40–360/370°C 54102<br />

0.25mm 1.00µm -40–360/370°C 54123<br />

0.32mm 0.25µm -40–360/370°C 54146<br />

0.32mm 1.00µm -40–360/370°C 54154<br />

0.53mm 1.00µm -40–360/370°C 54158<br />

*Isothermal/Temp. program.<br />

BPX35 Capillary Columns (continued)<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

30m 0.25mm 0.25µm 0–360/370°C 54701<br />

0.25mm 0.50µm 0–360/370°C 547025<br />

0.25mm 1.00µm 0–360/370°C 54704<br />

0.32mm 0.25µm 0–360/370°C 54724<br />

0.32mm 0.50µm 0–360/370°C 547158<br />

0.32mm 1.00µm 0–360/370°C 54717<br />

0.53mm 0.50µm 0–360/370°C 54735<br />

0.53mm 1.00µm 0–360/370°C 54737<br />

60m 0.25mm 0.25µm 0–360/370°C 54702<br />

0.25mm 1.00µm 0–360/370°C 54705<br />

0.32mm 0.25µm 0–360/370°C 54725<br />

*Isothermal/Temp. program.<br />

BPX50 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

15m 0.25mm 0.25µm 40–360/370°C 54750<br />

0.32mm 0.25µm 40–360/370°C 54760<br />

0.53mm 0.50µm 40–360/370°C 54769<br />

30m 0.25mm 0.25µm 40–360/370°C 54751<br />

0.32mm 0.25µm 40–360/370°C 54761<br />

0.53mm 0.50µm 40–360/370°C 54771<br />

*Isothermal/Temp. program.<br />

BPX70 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

15m 0.25mm 0.25µm 50–260/290°C 54621<br />

0.53mm 0.50µm 50–260/290°C 54619<br />

30m 0.25mm 0.25µm 50–260/290°C 54622<br />

0.32mm 0.25µm 50–260/290°C 54616<br />

0.53mm 0.50µm 50–260/290°C 54620<br />

60m 0.25mm 0.25µm 50–260/290°C 54623<br />

0.32mm 0.25µm 50–260/290°C 54617<br />

120m 0.25mm 0.25µm 50–260/290°C 54624<br />

*Isothermal/Temp. program.<br />

1<br />

2<br />

EPA Method 625 — Phenols<br />

5<br />

3<br />

4<br />

6<br />

7<br />

8<br />

9 10 11<br />

1871<br />

1. Phenol<br />

2. 2-Chlorophenol<br />

3. 2,4-Dinitrophenol<br />

4. 2-Nitrophenol<br />

5. 2,4-Dichlorophenol<br />

6. 4-Chloro-3-methylphenol<br />

7. 2,4,6-Trichlorophenol<br />

8. 2,4-Dinitrophenol<br />

9. 4-Nitrophenol<br />

10. 2-Methyl-4,6-dinitrophenol<br />

11. Pentachlorphenol<br />

gc columns | capillary<br />

BPX35 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

15m 0.25mm 0.25µm 0–360/370°C 54700<br />

0.25mm 1.00µm 0–360/370°C 54703<br />

0.32mm 0.25µm 0–360/370°C 54723<br />

0.32mm 1.00µm 0–360/370°C 54716<br />

0.53mm 0.50µm 0–360/370°C 54734<br />

0.53mm 1.00µm 0–360/370°C 54736<br />

*Isothermal/Temp. program.<br />

more info<br />

This is a partial listing of SGE ® Capillary Columns available from<br />

<strong>Grace</strong>. To view <strong>Grace</strong>’s complete chromatogram library, visit<br />

www.discoverysciences.com/chromdb/.<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

SGE ® BPX-5, 25m x 0.32mm x 0.50µm<br />

(Part No. 52318)<br />

125°C to 250°C (5min hold) at 15°C/min<br />

Hydrogen at 1.4mL/min<br />

FID<br />

www.discoverysciences.com<br />

237


gas chromatography<br />

gc columns | capillary<br />

SGE ® BPX Capillary Columns<br />

(continued)<br />

BPX90 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max. Part No.<br />

15m 0.25mm 0.25µm 75–280°C 54570<br />

0.32mm 0.50µm 75–280°C 54573<br />

30m 0.25mm 0.25µm 75–280°C 54580<br />

0.32mm 0.50µm 75–280°C 54583<br />

60m 0.25mm 0.25µm 75–280°C 54590<br />

0.32mm 0.50µm 75–280°C 54593<br />

BPX 608 Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

25m 0.32mm 0.4µm 0–360/370°C 54823<br />

*Isothermal/Temp. program.<br />

BPX Volatiles Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

20m 0.18mm 1µm 0–290/300°C 54978<br />

30m 0.25mm 1.4µm 0–290/300°C 54980<br />

0.32mm 1.8µm 0–290/300°C 54982<br />

0.53mm 3µm 0–290/300°C 54984<br />

40m 0.18mm 1µm 0–290/300°C 54979<br />

60m 0.25mm 1.4µm 0–290/300°C 54981<br />

0.32mm 1.8µm 0–290/300°C 54983<br />

0.53mm 3µm 0–290/300°C 54985<br />

*Isothermal/Temp. program.<br />

SGE ® HT5—<br />

5% Phenyl (equiv.)<br />

Polycarborane-siloxane<br />

• A unique high-temperature phase<br />

HT5 Polyimide Clad Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

15m 0.25mm 0.1μm 10–380/400°C 054633<br />

0.32mm 0.5μm 10–380/400°C 054667<br />

0.53mm 0.5μm 10–380/400°C 054671<br />

30m 0.25mm 0.1μm 10–380/400°C 054634<br />

0.32mm 0.5μm 10–380/400°C 054668<br />

0.53mm 0.5μm 10–380/400°C 054672<br />

*Isothermal/Temp. program.<br />

HT5 Aluminum Clad Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits*<br />

min.–max.<br />

Part No.<br />

12m 0.32mm 0.10μm 10–460/480°C 054651<br />

0.53mm 0.15μm 10–460/480°C 054662<br />

50m 0.32mm 0.10μm 10–460/480°C 054653<br />

*Isothermal/Temp. program.<br />

SGE ® SolGeL Capillary<br />

Columns<br />

• Unique technology encapsulates phase in synthetic glass<br />

• Greater inertness and thermal stability than “coated”<br />

phases<br />

SolGeL-WAX Capillary Columns<br />

• Highest temperature polyethylene glycol column<br />

• Maximum temperature 300°C<br />

• Ideal for: essential oils, food additives, industrial solvents,<br />

unreacted latex monomers, mixtures of aromatic<br />

hydrocarbons (e.g., BTEX), FAMEs, and mixtures of<br />

alcohols, esters, aldehydes, and ketones<br />

SolGeL-WAX is a bonded polyethylene glycol stationary<br />

phase. It is unique technology because the phase is<br />

encapsulated in synthetic glass (SolGeL material) and the<br />

whole matrix is itself bonded to the surface of the fused silica.<br />

This process leads to a very inert high-temperature column.<br />

SolGeL-WAX Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max.<br />

Part No.<br />

30m 0.25mm 0.25µm 0–300°C 54706<br />

0.32mm 0.50µm 0–300°C 54707<br />

60m 0.25mm 0.25µm 0–300°C 54708<br />

0.32mm 0.50µm 0–300°C 54709<br />

SolGeL-1ms Capillary Columns<br />

• MS-grade capillary columns<br />

• Maximum temperature 380°C<br />

• Ideal for: essential oils, pharmaceuticals, food additives,<br />

industrial solvents, and hydrocarbons<br />

SolGeL-1ms is a low bleed bonded polydimethylsiloxane<br />

(100% methyl) stationary phase encapsulated in synthetic<br />

glass (SolGeL material) and the whole matrix is itself bonded<br />

to the surface of the fused silica capillary. The anchoring of<br />

the matrix to the glass surface using this unique technology<br />

leads to a very inert, high-temperature column.<br />

SolGeL-1ms Capillary Columns<br />

Length i.d. Film<br />

Temp. Limits<br />

min.–max.<br />

Part No.<br />

30m 0.25mm 0.25µm 0–380°C 54715<br />

0.32mm 0.25µm 0–380°C 54718<br />

60m 0.25mm 0.25µm 0–380°C 54713<br />

0.32mm 0.25µm 0–380°C 54714<br />

238 www.discoverysciences.com


gas chromatography<br />

Alltech ® Custom Packed Metal and PTFE Columns<br />

Before ordering a custom-packed GC column, consult the list of popular packed columns on pages 244–245 to see if the column<br />

you need is there. Each column comes complete with brass nuts and brass ferrules. For assistance or a quote, please contact<br />

Technical Support.<br />

Coiling Schematics<br />

A<br />

A<br />

B<br />

C<br />

D<br />

C<br />

B<br />

D<br />

A<br />

C<br />

B<br />

D<br />

2483 2484<br />

2485<br />

Figure 1 Figure 2<br />

Figure 3<br />

C<br />

A<br />

D<br />

B<br />

2486 2487<br />

2488<br />

Figure 4 Figure 5<br />

Figure 6<br />

A<br />

C<br />

E<br />

D<br />

B<br />

C<br />

A<br />

D<br />

B<br />

Custom Metal and PTFE Columns — Ordering Instructions<br />

Specify Coiling<br />

1) Instrument Make and Model: ______________________<br />

2) Configuration Number: (see coiling schematics) ______<br />

3) Dimensions: A= ______ in/mm (circle one)<br />

B= ______ in/mm (circle one)<br />

C= ______ in/mm (circle one)<br />

D= ______ in/mm (circle one)<br />

E= ______ in/mm (circle one)<br />

F= ______ in/mm (circle one)<br />

X= ______ in/mm (circle one)<br />

4) Column Length: ______ ft/m (circle one)<br />

5) Column i.d.: ______ in/mm (circle one)<br />

6) Column o.d.: ______ in/mm (circle one)<br />

7) Tubing Material: (circle one)<br />

Stainless Steel AT-Steel Nickel PTFE<br />

TFE-Coated SS Aluminum Copper<br />

8) Solid Support: ______ Mesh Size: ______<br />

Specify Packing<br />

Choose either a Pretested Packing (p368–369) or create your own custom<br />

(refer to p370–371) by specifying information below:<br />

9) Stationary Phase A: ______ % Loading: ______<br />

Stationary Phase B*: ______ % Loading: ______<br />

Stationary Phase C*: ______ % Loading: ______<br />

10) Mirror Image:<br />

______ Please check if a mirror image is required.<br />

11) Injection Port Design: (circle one)<br />

on-column not on-column<br />

12) Stainless Steel Fittings:<br />

______ Please check if stainless steel fittings are required<br />

(PN: C-14010N)<br />

13) Preconditioning:<br />

______ Please check if column preconditioning is required<br />

(PN: C-14005)<br />

14) Other Special Instructions: (please be specific)<br />

________________________________________________<br />

________________________________________________<br />

________________________________________________<br />

gc columns | packed<br />

C<br />

*Additional charge applies to dual- and triple-coated packings (Part No. C-14020).<br />

A<br />

B<br />

D<br />

E<br />

F<br />

E<br />

C<br />

B<br />

D<br />

F<br />

A<br />

X<br />

B<br />

A<br />

Custom Packed Columns<br />

Description<br />

Part No.<br />

Custom Packed Columns<br />

C-5000<br />

(Specify all information from Table 1)<br />

Empty Columns<br />

Empty Column with Fittings and Ferrules C-5100<br />

Additional Charges (per Column)<br />

Preconditioned Column C-14005<br />

Stainless Steel Fittings<br />

C-14010N<br />

Dual- and Triple-Coated Packings C-14020<br />

2489 2490<br />

2491<br />

Figure 7 Figure 8<br />

Figure 9<br />

more info<br />

Certain expensive stationary phases and packings may require a<br />

surcharge. Be sure to state coiling instructions.<br />

www.discoverysciences.com<br />

239


gas chromatography<br />

Alltech ® GC Packed Columns<br />

Custom Deactiglas ® Glass<br />

• Silane treated for inertness<br />

• Precision bore glass for reproducibility<br />

• Brass fittings and vespel/graphite ferrules included<br />

• Available packed or empty<br />

Key to Configurations for Glass Columns<br />

A1 (Arm 1)<br />

S (Span)<br />

A2 (Arm 2)<br />

A1 (Arm 1)<br />

gc columns | packed<br />

Alltech ® Deactiglas ® GC Columns are fabricated from<br />

precision-bore (2mm ±0.05mm or 4mm ±0.1mm i.d.) glass.<br />

All columns are 1/4" o.d. unless otherwise specified. Columns<br />

longer than 2 meters may have joints. Several additional<br />

services such as stainless steel fittings and preconditioning<br />

of the packing are available. Certain expensive stationary<br />

phases and packings may require a surcharge.<br />

Due to space limitations we are not able to list all of the<br />

different manufacturers columns in our catalog. However,<br />

they are still available and can be specified at time of order<br />

placement. If you do not see your instrument on the following<br />

pages, please call Customer Service.<br />

Special Services for Glass Columns<br />

Description<br />

Part No.<br />

Stainless Steel Fittings (Per Column)<br />

C-14010N<br />

Preconditioned Packing (Per Column) C-14005<br />

5290<br />

A1 (Arm 1)<br />

A2 (Arm 2)<br />

A2 (Arm 2)<br />

S (Span)<br />

S (Span)<br />

Deactiglas ® Column Ordering Instructions:<br />

1. Choose column configuration part no. below.<br />

2. Choose either a pretested packing (p247–248) or create a custom<br />

packing (refer to p249–250) by specifying information below:<br />

Stationary Phase A<br />

% Loading<br />

Stationary Phase B<br />

% Loading<br />

Stationary Phase C<br />

% Loading<br />

0043<br />

Deactiglas ® Glass GC Columns<br />

Chromatograph Configuration Length i.d.<br />

Agilent 5830, 5840, 5985<br />

2513<br />

Packed<br />

Part No.<br />

Empty<br />

Part No.<br />

On-Column Injection<br />

A1 = 10.72" (272mm) 3ft 2mm 131122 131121<br />

A2 = 7.18" (182mm) 6ft 2mm C6067 6067<br />

S = 6" (152mm) 6ft 4mm C6076 6076<br />

4691<br />

Not On-Column Injection<br />

A1 = 8.95" (227mm) 3ft 2mm C6564 6564<br />

A2 = 9.25" (235mm) 6ft 2mm C6568 6568<br />

S = 6" (152mm) 6ft 4mm C6572 6572<br />

On-Column Injection<br />

A1 = 10.72" (272mm) 6ft 2mm C6055 6055<br />

A2 = 7.18" (182mm) 6ft 4mm C6061 6061<br />

S = 9" (229mm)<br />

2514<br />

Not On-Column Injection<br />

A1 = 8.95" (227mm) 6ft 2mm C6578 6578<br />

A2 = 9.25" (235mm) 6ft 4mm C6580 6580<br />

S = 9" (229mm)<br />

4695<br />

240 www.discoverysciences.com


gas chromatography<br />

Alltech ® GC Packed Columns<br />

Custom Deactiglas ® Glass<br />

Deactiglas ® Glass GC Columns (continued)<br />

Chromatograph Configuration Length i.d.<br />

Agilent 5880, 5890, 5987, 6890*<br />

2515<br />

Packed<br />

Part No.<br />

Empty<br />

Part No.<br />

3ft 2mm 130962 130961<br />

3ft 4mm 130972 130971<br />

4ft 2mm C6082 6082<br />

Configuration A 4ft 4mm C6085 6085<br />

On-Column Injection 6ft 2mm C6087 6087<br />

A1 = 11.02" (280mm) 6ft 4mm C6089 6089<br />

A2 = 9.05" (230mm) 2m 2mm C6336 6336<br />

S = 9" (229mm) 2m 4mm C6343 —<br />

FID 8ft 2mm C6347 6347<br />

1.8m 3mm C6346 6346<br />

10ft 2mm C6091 6091<br />

10ft 4mm 131552 131551<br />

4692<br />

6ft 2mm C6368 6368<br />

Configuration B 6ft 4mm C6391 6391<br />

On-Column Injection 2m 2mm C6393 6393<br />

A1 = 11.02" (280mm) 2m 4mm C6396 6396<br />

A2 = 7.09" (180mm) 8ft 2mm C6413 6413<br />

S = 9" (229mm) 1.8m 3mm C6346 6346<br />

TCD 10ft 2mm C6431 6431<br />

10ft 4mm C6435 6435<br />

3ft 2mm C6427 6427<br />

3ft 4mm C6433 6433<br />

Configuration C 4ft 2mm C6436 6436<br />

Not On-Column Injection 4ft 4mm C6440 6440<br />

A1 and A2 = 9.05" (230mm) 6ft 2mm C6442 6442<br />

S = 9" (229mm) 6ft 4mm C6445 6445<br />

All Detectors 2m 2mm C6447 6447<br />

Use with Liner or 2m 4mm C6449 6449<br />

Disposable Insert 8ft 2mm C6452 6452<br />

4693<br />

2.4m 2mm C6454 6454<br />

10ft 2mm C6456 6456<br />

10ft 4mm C6460 6460<br />

PerkinElmer ® 115, 300, 900, 910, 990, F30, 2000, 2100, 3920, Sigma Series<br />

2ft 2mm 132442 132441<br />

3ft 2mm 131432 131431<br />

3ft 4mm 131442 131441<br />

1m 2mm C6437 6437<br />

4ft 2mm C6148 6148<br />

Not On-Column Injection 4ft 4mm C6150 6150<br />

A1 = 9" (229mm) 6ft 2mm C6152 6152<br />

A2 = 9" (229mm) 6ft 4mm C6154 6154<br />

S = 8.75" (222mm) 2m 2mm C6439 6439<br />

2m 4mm C6441 6441<br />

8ft 2mm C6443 6443<br />

2530<br />

2.4m 2mm C6446 6446<br />

10ft 2mm C6105 6105<br />

12ft 2mm C6448 6448<br />

gc columns | packed<br />

2531<br />

3ft 2mm C6451 6451<br />

1m 2mm C6453 6453<br />

On-Column Injection 6ft 2mm C6149 6149<br />

A1 = 12.62" (321mm) 6ft 4mm C6151 6151<br />

A2 = 7.09" (180mm) 2m 2mm C6455 6455<br />

S = 8.75" (222mm) 2m 4mm C6458 6458<br />

2.4m 2mm C6462 6462<br />

10ft 2mm C6106 6106<br />

more info<br />

For explanation of A1, A2, and S, refer to key on page 240.<br />

www.discoverysciences.com<br />

241


gas chromatography<br />

Alltech ® GC Packed Columns<br />

Custom Deactiglas ® Glass<br />

Deactiglas ® Glass GC Columns (continued)<br />

Chromatograph Configuration Length i.d.<br />

PerkinElmer ® 8300, 8400, 8700 Series, 9000 Series, Autosystem<br />

2534A<br />

Packed<br />

Part No.<br />

Empty<br />

Part No.<br />

3ft 2mm C6464 6464<br />

Not On-Column Injection 1m 2mm C6466 6466<br />

A1 = 6.75" (171mm) 6ft 2mm C6479 6479<br />

A2 = 6.75" (171mm) 6ft 4mm C6482 6482<br />

S = 6.5" (165mm) 2m 2mm C6468 6468<br />

2m 4mm C6584 6584<br />

2.4m 2mm C6471 6471<br />

gc columns | packed<br />

3ft 2mm C6474 6474<br />

On-Column Injection 1m 2mm C6477 6477<br />

A1 = 12" (305mm) 4ft 2mm C6243 6243<br />

A2 = 6.75" (171mm) 4ft 4mm C6245 6245<br />

S = 6.5" (165mm) 6ft 2mm C6247 6247<br />

6ft 4mm C6249 6249<br />

2534B<br />

2m 2mm C6484 6484<br />

Shimadzu ® 4BF, 4BM, 4CM, 4MG, 6A, 6AM, 7AG (No Fittings Included)<br />

A1 = 13.2" (335mm) 1.7m 3mm C6509 6509<br />

A2 = 11.1" (282mm) 2m 2mm* C6349 6349<br />

S = 1.57" (40mm) 2m 3mm C6485 6485<br />

2537<br />

5mm o.d. Tubing 2m 4mm* C6359 6359<br />

2.5m 3mm C6515 6515<br />

Shimadzu ® 8A, RIA, GC-8A8IF (No Fittings Included)<br />

1m 3mm C6489 6489<br />

A1 = 9" (229mm) 1.5m 2.6mm C6598 6598<br />

A2 = 9" (229mm) 1.5m 3mm C6658 6658<br />

S = 6" (152mm) 2m 2mm* C6281 62811<br />

5mm o.d. Tubing 2m 2.6mm C6673 6673<br />

2m 3mm C6493 6493<br />

2539<br />

2m 4mm* C6334 6334<br />

Shimadzu ® 7A, 9A, 12A, 14A, 14B, 15A, 16A (No Fittings Included)<br />

1m 2.6mm C6487 6487<br />

1m 3mm C6497 6497<br />

1.7m 2.6mm C6491 6491<br />

A1 = 10.69" (272mm) 1.7m 3mm C6495 6495<br />

A2 = 12.81" (327mm) 2m 2mm* C6337 6337<br />

S = 1.57" (40mm) 2m 2.6mm C6498 6498<br />

2538<br />

5mm o.d. Tubing 2m 3mm C6499 6499<br />

2m 4mm* C6367 6367<br />

2.4m 2.6mm C6501 6501<br />

2.4m 3mm C6505 6505<br />

Varian ® 3300, 3400<br />

3ft 2mm C6558 6558<br />

Injector B to Detector B 4ft 2mm C6261 6261<br />

A1 = 9.5" (241mm) 4ft 4mm C6263 6263<br />

A2 = 8.1" (206mm) 6ft 2mm C6265 6265<br />

S = 6.82" (173mm) 6ft 4mm C6283 6283<br />

FID 2m 2mm C6340 6340<br />

2549<br />

2m 4mm C6342 6342<br />

*1/4" o.d. Column tapered to 5mm o.d. x 2.6mm i.d. ends.<br />

more info<br />

For explanation of A1, A2, and S, refer to page 240.<br />

242 www.discoverysciences.com


gas chromatography<br />

Alltech ® GC Packed Columns<br />

Custom Deactiglas ® Glass<br />

Deactiglas ® Glass GC Columns (continued)<br />

Chromatograph Configuration Length i.d.<br />

Varian ® 3300, 3400,3600, 3700, 4400, 4600, 6000 Vista Series<br />

Packed<br />

Part No.<br />

Empty<br />

Part No.<br />

3ft 2mm 131662 131661<br />

3ft 4mm 131672 131671<br />

1m 2mm C6306 6306<br />

1m 4mm C6308 6308<br />

Injector A to Detector A 4ft 2mm C6189 6189<br />

A1 = 9.5" (241mm) 4ft 4mm C6190 6190<br />

A2 = 8.1" (206mm) 6ft 2mm C6191 6191<br />

S = 5.5" (140mm) 6ft 4mm C6192 6192<br />

FID 2m 2mm C6310 6310<br />

0050A<br />

2m 4mm C6312 6312<br />

2.4m 2mm C6560 6560<br />

10ft 2mm C6197 6197<br />

10ft 4mm 131692 131691<br />

4m 2mm C6314 6314<br />

4m 4mm C6316 6316<br />

Varian ® Universal Columns 3300, 3400, 3600, 3700, 4400, 4600, 6000 Vista Series<br />

3ft 2mm C6562 6562<br />

6ft 2mm C6206 6206<br />

A1 = 9.5" (241mm) 6ft 4mm C6208 6208<br />

A2 = 2.25" (57mm) 2m 2mm C6356 6356<br />

0050C<br />

S = N/A 2m 4mm C6358 6358<br />

FID, TCD, ECD 4m 2mm C6360 6360<br />

4m 4mm C6366 6366<br />

more info<br />

For explanation of A1, A2, and S, refer to page 240.<br />

Adapter Kit<br />

Description<br />

Part No.<br />

Universal Adapter Kit 6210<br />

gc columns | packed<br />

more info<br />

Universal Glass Column Adapters are available for the Varian ®<br />

3000 and Varian ® 3700/Vista Series. Please contact Customer<br />

Service for part numbers and prices.<br />

Hi-EFF Pre-Columns<br />

• Extend column life<br />

• Reduce sample clean-up<br />

• Perform reaction chromatography<br />

• Perform subtraction chromatography<br />

To order a Hi-EFF Pre-Column, state catalog number and,<br />

if packed, describe the packing (% load, phase, support, and<br />

mesh). Glass and glass-lined stainless steel and columns are<br />

deactivated at no charge.<br />

Deactiglas ® Column Inlet<br />

Liners<br />

• Prolong the life of your glass columns<br />

• Silane-treated for inertness<br />

• Available for 2mm or 4mm i.d. columns<br />

• Inserts directly into the end of your column<br />

Deactiglas ®<br />

Column<br />

Inlet Liner<br />

2mm i.d. Column<br />

4mm i.d. Column<br />

Glass Wool<br />

Column Packing<br />

Hi-EFF Pre-Columns<br />

Packed<br />

Part No.<br />

Empty<br />

Part No.<br />

Description Length Qty.<br />

1/8" SS 6" 6 5900 5910<br />

1/4" Glass with Guide 6" 6 5902 5912<br />

1/8" Glass-Lined SS 6" 3 5904 5914<br />

1/8" Bottom-Drilled SS Union — ea — 5920<br />

1/4" Bottom-Drilled SS Union — ea — 5921<br />

Deactiglas ® Column Inlet Liners<br />

Description Qty. Part No.<br />

For 2mm i.d. Columns 10 6301<br />

For 2mm i.d. Columns 50 6302<br />

For 4mm i.d. Columns 10 6303<br />

For 4mm i.d. Columns 50 6304<br />

Glass Wool Inserter/Remover 2 6292<br />

www.discoverysciences.com<br />

243


gas chromatography<br />

Alltech ® Popular GC Packed Columns<br />

These columns are 6' x 1/8" o.d. 304 premium grade,<br />

precleaned stainless steel (unless otherwise indicated).<br />

Each column is made with preconditioned, pretested packing<br />

and comes complete with fittings, packing quality control<br />

chromatogram, column tags, and conditioning instructions.<br />

Popular Packed Column Ordering Instructions:<br />

1. Choose the part no. for your column from pages 244–245.<br />

2. Specify make and model of GC.*<br />

3. If your column is not listed, see page 239 for custom columns.<br />

*If no coiling instructions are provided, we will supply in a nominal 6" coil.<br />

gc columns | packed<br />

Popular GC Packed Columns<br />

Packing Description Dimensions* Part No.<br />

Alumina F-1, 60/80 5' x 1/8" SS Tubing 5664PC<br />

1% AT-1000 on Carbograph 1, 60/80 14404<br />

1% AT-1000 on Carbograph 1, 60/80 24' x 1/8" SS Tubing 14468<br />

10% AT-1000 on Chromosorb ® W-AW, 80/100 12001PC<br />

0.10% AT-1000 on Graphpac-GC, 80/100 8542PC<br />

10% Carbowax ® 1500 on Chromosorb ® T, 40/60 14479<br />

6.6% Carbowax ® 20M on Carbograph 1 AW, 80/100 10' x 1/8" SS Tubing 14473<br />

5.0% Carbowax ® 20M on Chromosorb ® W-HP, 80/100 14482<br />

10% Carbowax ® 20M on Chromosorb ® W-AW, 80/100 12005PC<br />

10% Carbowax ® 20M on Chromosorb ® W-HP, 80/100 12106PC<br />

6.6% Carbowax ® 20M on Graphpac-GB, 80/120 10' x 1/8" SS Tubing 14472<br />

0.20% Carbowax ® 1500 on Graphpac-GC, 80/100 8546PC<br />

Carbosphere, 60/80<br />

5680PC<br />

Carbosphere, 80/100 10' x 1/8" SS Tubing 56821PC<br />

Carbosphere, 80/100<br />

5682PC<br />

Chemipack C18, 80/100<br />

2768PC<br />

Chromosorb ® 101, 80/100<br />

2406PC<br />

Chromosorb ® 102, 80/100<br />

2409PC<br />

Chromosorb ® 107, 80/100<br />

2424PC<br />

Chromosorb ® 107, 80/100 6' x 1/8" TFE Tubing 9783<br />

Chromosorb ® 750, 80/100 4' x 1/8" SS Tubing 14480<br />

30% DC-200 (500cstks) on Chromosorb ® P-AW, 60/80 14481<br />

30% DC-200 (500cstks) on Chromosorb ® P-AW, 60/80 30' x 1/8" SS Tubing 12713PC<br />

10% FFAP on Chromosorb ® W-AW, 80/100 8434PC<br />

Gas Chrom 220, 80/100<br />

2484PC<br />

Gas Chrom 254, 80/100<br />

2486PC<br />

Gas Chrom MP-1, 100/120 30' x 1/8" SS Tubing 4945PC<br />

HayeSep ® A, 80/100 14484<br />

HayeSep ® A, 120/140 40' x 1/8" SS Tubing 28211<br />

HayeSep ® B, 80/100 14485<br />

HayeSep ® D, 80/100 14487<br />

HayeSep ® D, 100/120 3' x 1/8" SS Tubing 14486<br />

HayeSep ® D, 100/120 20' x 1/8" Ni Tubing 27082PC<br />

HayeSep ® D, 100/120 30' x 1/8" SS Tubing 27083PC<br />

HayeSep ® D, 100/120 10' x 1/8" SS Tubing 28301PC<br />

HayeSep ® DB, 100/120 30' x 1/8" SS Tubing 2836PC<br />

HayeSep ® Dip, 100/120 9' x 1/8" SS Tubing 2833PC<br />

HayeSep ® N, 80/100 14488<br />

HayeSep ® Q, 60/80 14490<br />

HayeSep ® Q, 80/100 8' x 1/8" SS Tubing 28010PC<br />

HayeSep ® Q, 80/100<br />

2801PC<br />

HayeSep ® Q, 100/120 14489<br />

HayeSep ® P, 60/80 8' x 1/8" SS Tubing 2803PC<br />

HayeSep ® P, 80/100<br />

2804PC<br />

HayeSep ® R, 80/100<br />

2807PC<br />

HayeSep ® S, 100/120<br />

2811PC<br />

HayeSep ® T, 60/80 3' x 1/8" SS Tubing 14491<br />

HayeSep ® T, 80/100<br />

2813PC<br />

HayeSep ® T, 100/120 5' x 1/8" SS Tubing 2814PC<br />

*6' x 1/8" stainless steel unless otherwise specified.<br />

244 www.discoverysciences.com


gas chromatography<br />

Alltech ® Popular GC Packed Columns (continued)<br />

Popular GC Packed Columns** (continued)<br />

Packing Description Dimensions* Part No.<br />

5% Krytox ® 143 AC on Graphpac-GB 60/80 10' x 1/8" SS Tubing 85222<br />

Molecular Sieve 5A (Washed), 60/80 14494<br />

Molecular Sieve 5A (Washed), 80/100<br />

5605PC<br />

Molecular Sieve 5A (Washed), 80/100 10' x 1/8" SS Tubing 14495<br />

Molecular Sieve 13X (Washed), 60/80 5' x 1/8" SS Tubing 57730PC<br />

Molecular Sieve 13X (Washed), 80/100 3' x 1/8" SS Tubing 14492<br />

Molecular Sieve 13X (Washed), 80/100<br />

5773PC<br />

Molecular Sieve 13X (Washed), 80/100 10' x 1/8" SS Tubing 14493<br />

3% OV-1 on Chromosorb ® W-HP, 80/100 12716PC<br />

10% OV-101 on Chromosorb ® P-AW, 80/100 4' x 1/8" SS Tubing 14477<br />

10% OV-101 on Chromosorb ® P-AW, 80/100 14478<br />

20% OV-101 on Chromosorb ® P-AW, 80/100 14469<br />

3% OV-101 on Chromosorb ® W-HP, 80/100 12019PC<br />

3% OV-101 on Chromosorb ® W-HP, 100/120 12700PC<br />

20% OV-101 on Chromosorb ® W-HP, 80/100 14470<br />

10% OV-101 on Chromosorb ® W-HP, 80/100 12703PC<br />

3% OV-17 on Chromosorb ® W-HP, 100/120 12017PC<br />

3% OV-17 on Chromosorb ® W-HP, 80/100 12719PC<br />

0.19% Picric Acid on Graphpac-GC, 80/100 7' x 1/8" SS Tubing 85501PC<br />

Porapak ® N, 80/100 3' x 1/8" SS Tubing 14497<br />

Porapak ® N, 80/100<br />

2716PC<br />

Porapak ® N, 80/100 12' x 1/8" SS Tubing 14498<br />

Porapak ® N, 100/120 3' x 1/8" SS Tubing 14496<br />

Porapak ® P, 80/100 14499<br />

Porapak ® PS, 80/100 10' x 1/8" SS Tubing 14506<br />

Porapak ® PS, 100/120 3' x 1/8" SS Tubing 14500<br />

Porapak ® Q, 50/80 4' x 1/8" SS Tubing 14508<br />

Porapak ® Q, 50/80<br />

2700PC<br />

Porapak ® Q, 80/100 3' x 1/8" SS Tubing 14519<br />

Porapak ® Q, 80/100 12' x 1/8" SS Tubing 27012PC<br />

Porapak ® Q, 80/100<br />

2701PC<br />

Porapak ® Q, 100/120<br />

2702PC<br />

Porapak ® QS, 80/100<br />

2719PC<br />

Porapak ® R, 80/100<br />

2707PC<br />

Porapak ® S, 50/80 7' x 1/8" SS Tubing 2709PC<br />

Porapak ® S, 80/100<br />

2710PC<br />

Porapak ® T, 80/100<br />

2713PC<br />

5% SE-30 on Chromosorb ® W-HP, 80/100 12025PC<br />

10% SE-30 on Chromosorb ® W-HP, 80/100 12423PC<br />

Silica Gel Grade 12, 60/80 8' x 1/8" SS Tubing 14523<br />

Silica Gel Grade 12, 60/80 18' x 1/8" SS Tubing 5651PC<br />

Silica Gel Grade 12, 80/100 8' x 1/8" SS Tubing 14530<br />

10% Silar 10C on Chromosorb ® W-HP, 100/120 12430PC<br />

20% Squalane on Chromosorb ® P-AW, 80/100 3' x 1/8" SS Tubing 14471<br />

15% Squalane on Chromosorb ® P-AW-DMCS, 80/100 8' x 1/8" SS Tubing 5327PC<br />

Sulfur Gas Column 36' x 1/8" TFE Tubing 9779<br />

18" of Super Q, 80/100 30" x 1/8" TFE Tubing 9781<br />

Tenax ® TA, 60/80 4' x 1/8" SS Tubing 14538<br />

Tenax ® TA, 60/80<br />

4900PC<br />

Tenax ® TA, 80/100<br />

4901PC<br />

Tenax ® GR, 60/80<br />

4937PC<br />

Unibeads 1S, 60/80<br />

2752PC<br />

Unibeads 2S, 60/80<br />

2760PC<br />

Unibeads 3S, 60/80 14541<br />

Unibeads 3S, 80/100 14542<br />

VZN-1, 60/80 23' x 1/8" SS Tubing 84623PC<br />

10% Silicone UCW-98 on Chromosorb ® W-HP, 80/100 8493PC<br />

1% TCEP on Carbograph 1, 80/120 4' x 1/8" SS Tubing 14474<br />

*6' x 1/8" stainless steel unless otherwise specified. **To order, use the part number shown and specify the instrument for which it should be coiled.<br />

gc columns | packed<br />

www.discoverysciences.com<br />

245


gas chromatography<br />

Alltech ® CTR Concentric Packed Columns<br />

For Gas Analysis<br />

• CTR I is ideal for separating O2, N2, CH4, CO, CO2 at<br />

ambient conditions<br />

• CTR III is ideal for argon analysis in the presence of O2<br />

• Useful where two separate chromatographic runs are<br />

required to analyze one sample<br />

• Individually tested<br />

A CTR column is essentially a column within a column.<br />

This permits you to use two different packings for the analysis<br />

of your sample. The diagram shows the construction of the<br />

CTR column.<br />

Inner 1/8" o.d. Tube Containing<br />

Column Packing A<br />

Cut-away view of CTR column.<br />

Outer 1/4" o.d. Tube Containing<br />

Column Packing B<br />

3980<br />

gc columns | packed<br />

CTR I—Oxygen, Nitrogen, Methane, Carbon<br />

Monoxide, and Carbon Dioxide<br />

Until the CTR, no single column operating at room<br />

temperature has been designed to permit, in one analysis, all<br />

these components in air. The analysis is usually accomplished<br />

by separate runs or with expensive valves. The CTR I<br />

accomplishes this separation in less than nine minutes.<br />

Calibration Gas for CTR I Column—This special mixture is<br />

useful for calibrating Part No. 8700 CTR I columns. It contains<br />

approximately 15% CO2 + 7% CO + 7% O2 + 4.5% CH4 with<br />

the balance N2. It is supplied in a 4L push button can with a<br />

needle applicator.<br />

CTR III Argon Analysis Column<br />

The CTR III is special designed for the separation of argon in<br />

the presence of oxygen. The outer column contains a special<br />

adsorbent that removes oxygen allowing the elution of argon<br />

and nitrogen. The inner column allows the combined elution<br />

of a peak containing oxygen and argon and later nitrogen.<br />

This separation is accomplished at ambient temperatures<br />

in ten minutes.<br />

more info<br />

For GC Applications, see the GC Applications Section, pages<br />

462–493.<br />

CTR I Column<br />

Description<br />

Temp. Limit<br />

max.<br />

Part No.<br />

CTR I Column 275°C 8700<br />

Calibration Gas for CTR I — 9799<br />

CTR III Column<br />

Description<br />

Temp. Limit<br />

max.<br />

Part No.<br />

CTR III Argon Analysis Column 275°C 8725<br />

Additional Fittings<br />

Tube End Connector, 1/4" to 1/8" Tube — 14169<br />

CTR I — Air, CO, CH4, CO2, O2, N2<br />

1059<br />

CTR III — Argon in Air<br />

1060<br />

1 3<br />

2<br />

4<br />

5<br />

1. Air and Carbon Monoxide<br />

(Inner Column)<br />

2. Methane (Inner Column)<br />

3. Carbon Dioxide (Inner Column)<br />

4. Oxygen (Outer Column)<br />

5. Nitrogen (Outer Column)<br />

6. Methane (Outer Column)<br />

7. Carbon Monoxide (Outer Column)<br />

1<br />

2 3 4 1. Argon (Inner Column)<br />

2. Nitrogen (Inner Column)<br />

3. Oxygen + Argon (Outer<br />

Column)<br />

4. Nitrogen (Outer Column)<br />

6 7<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

Column: CTR I (Part No. 8700)<br />

Outer Column: 6ft x 1/4" Packed with Activated Molecular Sieve<br />

Inner Column: 6ft x 1/8" Packed with Porous Polymer Mixture<br />

Temp:<br />

Ambient<br />

Carrier Gas: Helium at 65mL/min<br />

Detector: TCD<br />

0 2 4 6 8 10 12 Min.<br />

Column: CTR III, 6ft x 1/4" SS (Part No. 8725)<br />

Outer Column: 6ft x 1/4" Packed with Activated Molecular Sieve<br />

Inner Column: 6ft x 1/8" Packed with Molecular Sieve and<br />

Oxy Adsorbent<br />

Temp:<br />

Ambient<br />

Carrier Gas: Helium at 70mL/min<br />

Detector: TCD<br />

246 www.discoverysciences.com


gas chromatography<br />

Pretested GC Packings<br />

Pretested packings are guaranteed and supplied with a test<br />

chromatogram. Preconditioning service is available for 20g<br />

or 25g of packing. The packing is heated at 25°C below the<br />

upper temperature limit for 3 hours with a flow of oxygen-free<br />

nitrogen.<br />

Preconditioning Services<br />

Description<br />

Packing Preconditioning Service (per 20–25 grams).<br />

Specify Pretested GC Packing Part Number.<br />

Part No.<br />

C-14000<br />

Pretested GC Packings<br />

Packing Description Temp. Limits Qty. Part No.<br />

Alumina F-1, 60/80 300°C 100g 5664<br />

1% AT-1000 on Carbograph 1, 60/80 250°C 15g 1733<br />

10% AT-1000 on Chromosorb ® W-AW, 80/100 250°C 20G 12001<br />

0.10% AT-1000 on Graphpac-GC, 80/100 225°C 15g 8542<br />

10% Carbowax ® 1500 on Chromosorb ® T, 40/60 175°C 20g 16146<br />

6.6% Carbowax ® 20M on Carbograph 1-AW, 80/120 60–225°C 15g 1731<br />

5.0% Carbowax ® 20M on Chromosorb ® W-HP, 80/100 60–225°C 20g 16147<br />

5.0% Carbowax ® 20M on Chromosorb ® T, 40/60 60–225°C 25g 8416<br />

10.0% Carbowax ® 20M on Chromosorb ® W-AW, 80/100 60–225°C 20g 12005<br />

10.0% Carbowax ® 20M on Chromosorb ® W-HP, 80/100 60–225°C 20g 12106<br />

4% Carbowax ® 20M + 0.8% KOH on Graphpac-GB, 60/80 220°C 15g 8519<br />

6.6% Carbowax ® 20m on Graphpac-GB, 80/120 175°C 15g 16148<br />

0.2% Carbowax ® 1500 on Graphpac-GC, 80/100 175°C 15g 8546<br />

Carbosphere ® , 60/80 400°C 5g 5680<br />

Carbosphere ® , 80/100 400°C 5g 5682<br />

Chemipack C18, 80/100 320°C 15mL 2768<br />

Chromosorb ® 101, 80/100 275/325°C 25g 16149<br />

Chromosorb ® 102, 80/100 250/300°C 25g 16150<br />

Chromosorb ® 107, 80/100 250/275°C 25g 16151<br />

Chromosorb ® 750, 80/100 250/275°C 25g 16152<br />

30% DC-200 (500 cstk) on Chromosorb ® P-AW, 60/80 20–200°C 25g 12713<br />

10% FFAP on Chromosorb ® W-AW, 80/100 50–250°C 25g 8434<br />

28% AT-223 + 4% KOH on Gas Chrom R, 80/100 200°C 25g 49259<br />

Gas Chrom 220, 80/100 250°C 25g 2484<br />

Gas Chrom 254, 80/100 275°C 25g 2486<br />

Gas Chrom MP-1, 100/120 50–250°C 25g 16153<br />

HayeSep ® A, 80/100 165°C 15g 16154<br />

HayeSep ® A, 120/140 165°C 15g 16155<br />

HayeSep ® B, 80/100 190°C 15g 16156<br />

HayeSep ® D, 80/100 290°C 15g 16157<br />

gc columns | packed<br />

www.discoverysciences.com<br />

247


gas chromatography<br />

gc columns | packed<br />

Pretested GC Packings (continued)<br />

Pretested GC Packings (continued)<br />

Packing Description Temp. Limits Qty. Part No.<br />

HayeSep ® D, 100/120 290°C 15g 16166<br />

HayeSep ® DB, 100/120 290°C 15g 16169<br />

HayeSep ® Dip, 100/120 290°C 15g 16170<br />

HayeSep ® N, 80/100 165°C 15g 16172<br />

HayeSep ® Q, 60/80 275°C 15g 16196<br />

HayeSep ® Q, 80/100 275°C 15g 16197<br />

HayeSep ® Q, 100/120 275°C 15g 16198<br />

HayeSep ® P, 60/80 250°C 15g 16199<br />

HayeSep ® P, 80/100 250°C 15g 16210<br />

HayeSep ® R, 80/100 250°C 15g 16211<br />

HayeSep ® S, 100/120 250°C 15g 16212<br />

HayeSep ® T, 60/80 165°C 15g 16213<br />

HayeSep ® T, 80/100 165°C 15g 16214<br />

HayeSep ® T, 100/120 165°C 15g 16215<br />

5% Krytox ® 143AC on Graphpac GB, 60/80 175°C 15g 8522<br />

Molecular Sieve 5A (washed), 60/80 350°C 50g 5604<br />

Molecular Sieve 5A (washed), 80/100 350°C 50g 5605<br />

Molecular Sieve 13X (washed), 60/80 350°C 50g 57730<br />

Molecular Sieve 13X (washed), 80/100 350°C 50g 57732<br />

3% OV-1 on Chromosorb ® W-HP, 80/100 100–350°C 20g 12716<br />

10% OV-101 on Chromosorb ® P-AW, 80/100 20–350°C 20g 16216<br />

20% OV-101 on Chromosorb ® P-AW, 80/100 20–350°C 20g 16217<br />

3% OV-101 on Chromosorb ® W-HP, 80/100 20–350°C 20g 12019<br />

3% OV-101 on Chromosorb ® W-HP, 100/120 20–350°C 20g 12700<br />

20% OV-101 on Chromosorb ® P-AW, 80/100 20–350°C 20g 16218<br />

10% OV-101 on Chromosorb ® W-HP, 80/100 20–350°C 20g 12703<br />

3% OV-17 on Chromosorb ® W-HP, 100/120 20–350°C 20g 12017<br />

3% OV-17 on Chromosorb ® W-HP, 80/100 20–350°C 20g 12719<br />

0.19% Picric Acid on Graphpac-GC, 80/100 120°C 15g 8550<br />

Porapak ® N, 80/100 190°C 15g 16219<br />

Porapak ® N, 100/120 190°C 15g 16220<br />

Porapak ® P, 80/100 250°C 15g 16221<br />

Porapak ® PS, 80/100 250°C 15g 16223<br />

Porapak ® PS, 100/120 250°C 15g 16224<br />

Porapak ® Q. 50/80 250°C 15g 16225<br />

Porapak ® Q, 80/100 250°C 15g 16226<br />

Porapak ® Q, 100/120 250°C 15g 16228<br />

Porapak ® QS, 80/100 250°C 15g 16229<br />

Porapak ® R, 80/100 250°C 15g 16230<br />

Porapak ® S, 50/80 250°C 15g 16231<br />

Porapak ® S, 80/100 250°C 15g 16232<br />

Porapak ® T, 80/100 190°C 15g 16233<br />

Silica Gel Grade 12, 60/80 350°C 100g 5651<br />

Silica Gel Grade 12, 80/100 350°C 100g 5653<br />

20% Squalane on Chromosorb ® P-AW, 80/100 140°C 20g 16235<br />

15% Squalane on Chromosorb ® P-AW-DCMS, 80/100 140°C 20g 16236<br />

Tenax ® TA, 60/80 350°C 10g 04916<br />

Tenax ® TA, 80/100 350°C 10g 04917<br />

Tenax ® GR, 60/80 350°C 10g 4937<br />

Unibeads 1S, 60/80 200°C 25g 2752<br />

Unibeads 2S, 60/80 200°C 25g 2760<br />

Unibeads 3S, 60/80 200°C 25g 2764<br />

Unibeads 3S, 80/100 200°C 25g 2766<br />

VZN-1, 60/80 50°C 10g 8462<br />

1% TCEP on Carbograph 1, 80/120 180°C 15g 16270<br />

248 www.discoverysciences.com


gas chromatography<br />

Custom Coated Packings<br />

Before ordering a custom coated packing, please check the<br />

list of stock pretested packings on pages 247–248 (called<br />

"Pretested" on these pages). You may find the packing you<br />

need in stock and at a savings.<br />

Custom Coated Packing Ordering Instructions:<br />

1. Choose your solid support from Table 1.<br />

2. Specify mesh range.<br />

3. Choose the stationary phase from Table 3 or 4. It is possible to coat<br />

up to three stationary phases on one support).<br />

4. Specify % loading for each stationary phase. Note maximum %<br />

loading guidelines for each support in Table 2.<br />

Table 1—Base Price for Custom-Coated Packings<br />

20 Grams<br />

Part No.<br />

50 Grams<br />

Part No.<br />

100 Grams<br />

Part No.<br />

Solid Support<br />

Chromosorb ® G, W (HP) C-3004 C-3036 C-3068<br />

Chromosorb ® G, W, or P (NAW, AW, DMCS) C-3006 C-3038 C-3070<br />

Chromosorb ® T C-3008 C-3040 C-3072<br />

Chromosorb ® 101-108 C-2031 C-2032 —<br />

Chromosorb ® 750 C-3012 C-3044 C-3076<br />

Gas Chrom S C-3018 C-3050 C-3082<br />

Gas Chrom R C-3020 C-3052 C-3084<br />

Gas Chrom 220, 254 C-3022 C-3054 C-3086<br />

Graphpac-GC and -GB (15 grams), Carbograph C-2200 — —<br />

Porapak ® C-2041 C-2042 —<br />

Tenax ® or HayeSep ® (15 grams) C-3028 — —<br />

Table 2—Maximum Stationary Phase Loading for Solid Supports<br />

Max. Load Supported Material Max. Load Supported Material Max. Load Supported Material<br />

5% Chromosorb ® G 12% Chromosorb ® 750 2% Porapak ®<br />

15% Chromosorb ® W 15% Gas Chrom S, A, P, Z, and Q 2% Super Q<br />

25% Chromosorb ® A 30% Gas Chrom R 12% T-Port-F<br />

30% Chromosorb ® P 2% Gas Chrom 220 and 254 2% HayeSep ®<br />

12% Chromosorb ® T 0.5% Glass Beads 2% Tenax ®<br />

2% Chromosorb ® 101–108 8% Graphpac, Carbograph 15% Supelcoport<br />

gc columns | packed<br />

Stationary Phases<br />

Table 3—GC Stationary Phases<br />

Description<br />

Solvent<br />

Temp. Limits<br />

min.–max. USP Code Qty. Part No.<br />

Apiezon ® L Chloroform 50–300ºC — 25g 5017<br />

bis-(2-Ethoxyethyl) Adipate (BEEA) Chloroform 150ºC — 25g 5046<br />

Carbowax ® 400 Chloroform 20–100ºC G20 100g 5051<br />

Carbowax ® 20M Chloroform 60–225ºC G16 10g 5264<br />

DC-200, 350 cstk (Methyl) Chloroform 20–250ºC — 100g 5251<br />

Dexsil ® 300GC Chloroform 50–400ºC G33 1g 5092<br />

FFAP Chloroform 50–250ºC G35 20g 5156<br />

Hi-EFF-1BP (Diethyleneglycol Succinate) 1 Chloroform 20–200ºC G4 25g 09505<br />

Igepal ® CO-630 Methanol 30–200ºC — 50g 5175<br />

OV-1 (Methyl Gum) Chloroform 100–350ºC G2 10g 5293<br />

OV-17 (50% Phenyl) Acetone 20–350ºC G3 20g 5301<br />

OV-101 (Methyl Fluid) Chloroform 20–350ºC G1 20g 5309<br />

OV-275 (Dicyanoallyl) Chloroform 250ºC+ — 5g 5314<br />

QF-1 (50% Trifluoropropyl) Ethyl Acetate 20–250ºC — 25g 5269<br />

SE-30 (Methyl Gum) Chloroform 75–300ºC — 100g 5271<br />

Sebaconitrile Chloroform 150ºC — 20g 5244<br />

Silar 10C (100% Cyanopropyl Silicone) 2 Chloroform 50–250ºC G5 5g 5250<br />

Tetrahydroxyethylethylene Diamine (THEED) Methanol 125ºC — 25g 5347<br />

1<br />

U.S. Patent #3,239,997, 2 U.S. Patent #4,063,911.<br />

www.discoverysciences.com<br />

249


gas chromatography<br />

Custom Coated Packings<br />

Additional Stationary Phases for Custom Packings and Columns<br />

gc columns | packed<br />

Table 4—Stationary Phases<br />

AT-1000 bis-(2-Ethoxyethyl) Sebacate (BEES) OV-351<br />

Apiezon ® H Glycerin Poly-A ® 103<br />

Apiezon ® J Halocarbon 25-55 Grease Poly-A ® 135<br />

Apiezon ® K Halocarbon Oil 14-25 Poly-I 110<br />

Apiezon ® N Hexadecanol Poly-S 176<br />

BBBT Hi-EFF 1AP (Diethyleneglycol Adipate) Polyox 600M<br />

Bentone 34 Hi-EFF 2AP (Ethyleneglycol Adipate) Polyvinylpyrrolidone<br />

BHXBT Hi-EFF 2BP (Ethyleneglycol Succinate) Reoplex 400<br />

BMBT Hi-EFF 3BP (Neopentylglycol Succinate) SE-52<br />

BMEA Hi-EFF 3CP (Neopentylglycol Sebacate) SF-96<br />

Carbowax ® 540 Hi-EFF 8AP (Cyclohexanedimethanol Adipate) Sorbitol<br />

Carbowax ® 600 Igepal ® CO-880 SPAN 80<br />

Carbowax ® 1000 Igepal ® CO-990 Squalane<br />

Carbowax ® 1450 Kel-F ® Oil No. 3 SUPEROX ® 4<br />

Carbowax ® 20M-TPA Kel-F ® Oil No. 10 SUPEROX ® 20M<br />

CS-10 Kel-F ® Wax TCEPE<br />

N,N-bis-(2-Cyanoethyl) formamide (BCEF) Krytox ® 143AD TCEP<br />

DC-200 (500cstk) LAC 3-R-728 β,β-Thiodipropionitrile<br />

DC-410 LAC 4-R-886 Triton ® X-100<br />

DC-550 LAC 5-R-737 Triton ® X-305<br />

DC-702 Lexan (Polycarbonate Resin) TWEEN 80<br />

Di-n-butyl Maleate Neopentylglycol Succinate UC L-45<br />

Didecyl Phthalate Octyldecyl Adipate UCON 50-HB-280-X<br />

Di(2-ethylhexyl) Sebacate OV-7 UCON 75-H-90,000<br />

Di(2-ethylhexyl) Phthalate OV-17 Vinyl UCON LB-135<br />

Diglycerol OV-22 UCON LB-1715<br />

Diisodecyl Phthalate OV-105 UCON LB-550X<br />

Dimethyl Sulfolane OV-202 UCON LB-1800-X<br />

Dinonyl Phthalate OV-210 UC W-98<br />

ECNSS-M OV-215 Versamid ® 900<br />

EGSS-X OV-225 Versilube ® F-50<br />

Ethofat 60-25 OV-330 Versilube ® F-50<br />

Additional Charges for Custom Coated Packings<br />

Description<br />

Multiple Stationary Phases (per phase)<br />

Expensive Stationary Phases: Add the cost of the<br />

stationary phase used to base price<br />

Part No.<br />

C-2000<br />

—<br />

Acetone Washing C-2700<br />

technical assistance<br />

Need help selecting the right packing for your analysis?<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

related products<br />

Looking for GC packing accessories?<br />

See pages 262–263.<br />

5079<br />

5075<br />

250 www.discoverysciences.com


gas chromatography<br />

GC Supports<br />

Chromosorb ® Diatomite Supports<br />

Chromosorb ® A, G, P, and W are available in both<br />

untreated and treated forms, as well as in a choice of<br />

various mesh ranges.<br />

Chromosorb ® Specifications<br />

Chromosorb ®<br />

Series<br />

Surface<br />

Area<br />

Packed<br />

Density<br />

Type<br />

A Flux-calcined 2.7m 2 /g 0.48g/cc 25%<br />

G Flux-calcined 0.5m 2 /g 0.58g/cc 5%<br />

P Calcined 4.0m 2 /g 0.47g/cc 30%<br />

W Flux-calcined 1.0m 2 /g 0.24g/cc 15%<br />

750 Flux-calcined 0.75m 2 /g 0.40g/cc 12%<br />

Recommended<br />

Liquid Phase<br />

Load<br />

Chromosorb ® Treatment Specifications<br />

Abbreviation Treatments<br />

NAW<br />

Untreated (non-acid washed)<br />

AW<br />

Acid washed (HCL is used)<br />

DMCS<br />

Dimethyldichlorosilane (silanized)<br />

HP<br />

High performance QC’ed (acid washed, silanized,<br />

flux-calcined)<br />

Chromosorb ® Diatomite Supports<br />

Description Qty. Part No.<br />

Chromosorb ® A-NAW<br />

20/30 454g 2431<br />

45/60 454g 2432<br />

60/80 454g 2433<br />

Chromosorb ® G-NAW<br />

45/60 225g 23721<br />

60/80 225g 23731<br />

80/100 225g 23741<br />

100/120 225g 23751<br />

120/140 225g 23761<br />

Chromosorb ® G-AW<br />

45/60 225g 23821<br />

60/80 225g 23831<br />

80/100 225g 23841<br />

100/120 225g 23851<br />

Chromosorb ® G-AW-DMCS<br />

45/60 225g 23921<br />

60/80 225g 23931<br />

80/100 225g 23941<br />

100/120 225g 23951<br />

120/140 225g 23961<br />

Chromosorb ® G-HP<br />

60/80 225g 2396<br />

80/100 225g 2397<br />

100/120 225g 2398<br />

120/140 225g 2444<br />

Chromosorb ® Diatomite Supports (continued)<br />

Description Qty. Part No.<br />

Chromosorb ® P-NAW<br />

30/60 454g 2304<br />

45/60 454g 2305<br />

60/80 454g 2306<br />

80/100 454g 2307<br />

100/120 454g 2308<br />

Chromosorb ® P-AW<br />

30/60 454g 2314<br />

45/60 454g 2315<br />

60/80 454g 2316<br />

80/100 454g 2317<br />

100/120 454g 2318<br />

Chromosorb ® P-AW-DMCS<br />

45/60 454g 2323<br />

60/80 454g 2324<br />

80/100 454g 2325<br />

100/120 454g 2326<br />

Chromosorb ® W-NAW<br />

30/60 150g 23331<br />

45/60 150g 23341<br />

60/80 150g 23351<br />

80/100 150g 23361<br />

100/120 150g 23371<br />

120/140 150g 23381<br />

Chromosorb ® W-AW<br />

30/60 150g 23451<br />

45/60 150g 23461<br />

60/80 150g 23471<br />

80/100 150g 23481<br />

100/120 150g 23491<br />

Chromosorb ® W-AW-DMCS<br />

45/60 150g 23581<br />

60/80 150g 23591<br />

80/100 150g 23601<br />

100/120 150g 23611<br />

Chromosorb ® W-HP<br />

60/80 150g 24401<br />

80/100 150g 23651<br />

100/120 150g 23661<br />

120/140 150g 24421<br />

Chromosorb ® 750<br />

• Designed specifically for biomedical and pesticide<br />

analyses<br />

Chromosorb ® 750 is the most inert and highly efficient support<br />

material in the series. This support material is acid-washed,<br />

DMCS treated, and carefully screened.<br />

Chromosorb ® 750<br />

Description Qty. Part No.<br />

60/80 100g 2399<br />

80/100 100g 2400<br />

100/120 100g 2401<br />

gc columns | packed<br />

www.discoverysciences.com<br />

251


gas chromatography<br />

GC Supports and Packings<br />

Chromosorb ® T<br />

Chromosorb ® T is a support material made from PTFE and<br />

is useful for the analysis of polar compounds such as water,<br />

hydrazine, sulfur dioxide, etc.<br />

Chromosorb ® T melts at 327°C, starts to decompose at<br />

290°C, and fuses together under prolonged use at 250°C.<br />

The density is 0.42g/cc. The surface area is 7–8m 2 /g and<br />

maximum loading capacity is 12%. When packing, chill the<br />

material below 19°C.<br />

Gas Chrom<br />

Gas Chrom S is white diatomaceous earth that is screened<br />

and is non-acid washed. Use as a filtering agent or trapping<br />

material.<br />

Gas Chrom R is red diatomaceous earth that is screened<br />

and water washed to neutrality.<br />

Gas Chrom Porous Polymers 220 and 254 are low in<br />

residual monomers and contaminants, condition faster and<br />

have lower column bleed.<br />

Chromosorb ® T<br />

Description Qty. Part No.<br />

30/60 225g 24371<br />

40/60 225g 24381<br />

Gas Chrom Specifications<br />

Gas Chrom 254 Gas Chrom 220<br />

Pore Size: 3000nm 10nm<br />

Surface Area: 1000m 2 /g 450m 2 /g<br />

Equivalents: Porapak ® P Porapak ® Q<br />

gc columns | packed<br />

T-Port-F<br />

T-Port-F is a screened tetrafluoroethylene support useful for<br />

analysis of very polar compounds. It has a density of about<br />

0.5g/cc with a maximum temperature limit of 150°C.<br />

T-Port-F<br />

Description Qty. Part No.<br />

30/60 50g 2447<br />

60/80 50g 2448<br />

80/100 50g 2449<br />

Gas Chrom<br />

Description Qty. Part No.<br />

Gas Chrom S<br />

80/100 100g 03010<br />

Gas Chrom R<br />

40/60 100g 4956<br />

60/80 100g 4966<br />

80/100 100g 4976<br />

Gas Chrom Porous Polymer<br />

220, 80/100 25g 2484<br />

254, 80/100 25g 2486<br />

Stock Packed Columns<br />

6ft x 1/8" SS Column with Gas Chrom Porous ea 2484PC<br />

Polymer 220, 80/100<br />

6ft x 1/8" SS Column with Gas Chrom Porous<br />

Polymer 254, 80/100<br />

ea 2486PC<br />

Activated Alumina<br />

Activated alumina is useful for the analysis of light<br />

hydrocarbons. Unsaturated hydrocarbons are retained longer<br />

than saturated ones. Grade F-6 is an indicating alumina<br />

which turns from blue to pink upon adsorption of water. The<br />

maximum temperature limit is 300°C.<br />

Glass Beads<br />

Glass beads can be loaded up to 0.5 wt. % before becoming<br />

tacky. Two types are available: untreated (regular) or<br />

dimethyldichlorosilane (DMCS)-treated.<br />

Activated Alumina<br />

Description Qty. Part No.<br />

Grade F-1<br />

40/60 100g 5662<br />

60/80 100g 5664<br />

80/100 100g 5666<br />

100/120 100g 5668<br />

Grade F-6<br />

8/14 100g 05561<br />

Stock Packed Column<br />

5ft x 1/8" SS Packed with Alumina Grade F-1,<br />

60/80<br />

ea 5664PC<br />

Glass Beads<br />

Description Qty. Part No.<br />

Regular, 60/80 mesh 125g 5420<br />

Regular, 80/100 mesh 125g 5422<br />

Regular, 100/120 mesh 125g 5424<br />

DMCS Treated, 60/80 mesh 125g 5426<br />

DMCS Treated, 80/100 mesh 125g 5428<br />

DMCS Treated, 100/120 mesh 125g 5430<br />

252 www.discoverysciences.com


gas chromatography<br />

GC Packings<br />

Silica Gel<br />

Silica Gel is used for the analysis of fixed gases and light<br />

hydrocarbons. It is also useful for dehydration of gases<br />

and liquids.<br />

Grade 42 Indicating Silica Gel changes from blue to pink as<br />

it becomes saturated with water. It conforms to MIL-D-3716<br />

Type IV Grade H. It will absorb water up to about 40% by<br />

weight. The maximum temperature limit is 350°C.<br />

Silica Gel<br />

Unibeads S<br />

100g<br />

Part No.<br />

1kg<br />

Part No.<br />

Description<br />

Grade 12<br />

40/60 5650 05532<br />

60/80 5651 05533<br />

80/100 5653 05534<br />

100/120 5655 05535<br />

Grade 15<br />

35/60 5648 05545<br />

Indicating Silica Gel, Grade 42<br />

6/16 05559 05560<br />

Stock Packed Column<br />

18ft x 1/8" SS Packed with Silica Gel, 60/80, ea<br />

5651PC<br />

The Unibeads S series consists of spherical porous<br />

silica beads. Unibeads 2S are comparable to Porasil ® A.<br />

Unibeads 3S are similar to Porasil ® B. The smaller the pore<br />

size, the greater the retention for hydrocarbons.<br />

Chemipack ® C18<br />

Chemipack ® C18 is a chemically bonded GC packing.<br />

Because it is bonded, it has high thermal stability, zero<br />

bleed and stability to water. These properties make it ideal for<br />

GC/MS or high sensitivity GC with any detector. The functional<br />

group bonded to the silica is octadecyl.<br />

Chemipack ®<br />

Description Qty. Part No.<br />

Chemipack ® C18, 80/100, 320°C 15mL 2768<br />

Stock Packed Column<br />

6ft x 1/8" SS Packed with Chemipack ® C18,<br />

80/100, 320°C<br />

ea 2768PC<br />

Carbosphere—Carbon Molecular Sieve<br />

Carbosphere exhibits properties similar to molecular sieves.<br />

It has a surface area of about 1000m 2 /g with a pore size<br />

of about 13Å. Carbosphere separates oxygen, nitrogen,<br />

methane, carbon monoxide, and carbon dioxide in the same<br />

run. It also separates air, carbon dioxide, and the C1–C2<br />

hydrocarbons. At ambient temperatures, hydrogen will elute<br />

before oxygen.<br />

Carbosphere resolves trace amounts of methane and<br />

acetylene in ethylene and even trace amounts of methane,<br />

acetylene, and ethylene in ethane. The carbon molecular<br />

sieves also separate oxides of nitrogen and sulfur. Because<br />

Carbosphere is very nonretentive for water, rapid<br />

separations of organics, such as formaldehyde and methanol<br />

in water are possible.<br />

gc columns | packed<br />

Unibeads S<br />

Description Qty. Part No.<br />

1S, 60/80, 22A 25g 2752<br />

1S, 80/100, 22A 25g 2758<br />

2S, 60/80, 60A 25g 2760<br />

2S, 80/100, 60A 25g 2762<br />

3S, 60/80, 100A 25g 2764<br />

3S, 80/100, 100A 25g 2766<br />

Stock Packed Column<br />

6ft x 1/8" SS Packed with Unibeads 1S, 60/80 ea 2752PC<br />

6ft x 1/8" SS Packed with Unibeads 2S, 60/80 ea 2760PC<br />

It is important to remove every trace of oxygen from the<br />

carrier gas used on Carbosphere columns. This is essential<br />

if you are doing trace analysis or using temperatures above<br />

200°C. An oxygen purifier such as Oxy-Trap or Indicating<br />

Oxy-Trap is ideal for removal of oxygen from carrier gas.<br />

Carbosphere can be affected by contaminants in the air<br />

and in carrier gas. Store under pure nitrogen or argon gas.<br />

Carbosphere<br />

Description Qty. Part No.<br />

60/80 5g 5680<br />

80/100 5g 5682<br />

Stock Packed Columns<br />

6ft x 1/8" SS Packed with Carbosphere, 60/80 ea 5680PC<br />

6ft x 1/8" SS Packed with Carbosphere, 80/100 ea 5682PC<br />

10ft x 1/8" SS Packed with Carbosphere, 80/100 ea 56821PC<br />

related products<br />

Need an oxygen trap?<br />

See page 271.<br />

4653<br />

www.discoverysciences.com<br />

253


gas chromatography<br />

gc columns | packed<br />

GC Packings<br />

Molecular Sieves<br />

• For drying applications<br />

Molecular sieves are synthetic alkali metal alumino-silicates<br />

with various cations. They are used for the separation of<br />

fixed gases and drying of liquid or gas streams. They can<br />

be reactivated by heating at 250°C for 12 hours; 300°C for<br />

4 hours; or 350°C for 2 hours.<br />

Molecular Sieves<br />

100g<br />

Part No.<br />

1kg<br />

Part No.<br />

Description<br />

Molecular Sieve 3A<br />

1/8" Pellets 05252 05253<br />

1/16" Pellets 05254 05255<br />

40/60 05306 05295<br />

60/80 05307 05298<br />

80/100 05308 05301<br />

100/120 05309 05304<br />

Molecular Sieve 4A<br />

8/12 Beads 05256 05257<br />

1/8" Pellets 05258 05259<br />

1/16" Pellets 05260 05261<br />

40/60 5620 05345<br />

60/80 5622 05348<br />

80/100 5624 05351<br />

100/120 5625 05355<br />

Molecular Sieve 5A<br />

1/8" Pellets 05264 05265<br />

1/16" Pellets 5633 05267<br />

40/60 5626 05327<br />

60/80 5328 05330<br />

80/100 5630 05333<br />

100/120 5632 05336<br />

Molecular Sieve 13X<br />

8/12 Beads 05268 05269<br />

1/8" Pellets 05270 05271<br />

1/16" Pellets 05272 05273<br />

40/60 5634 05493<br />

60/80 5636 05496<br />

80/100 5638 05499<br />

100/120 5640 05502<br />

Washed Molecular Sieves<br />

• For chromatography applications<br />

The usual gas chromatographic grades of molecular sieves<br />

have a fine dust adhering to each particle which cannot be<br />

removed simply by careful sieving. This dust is responsible for<br />

poorer separations and higher pressure drops than molecular<br />

sieves which are essentially dust-free.<br />

The washed molecular sieves offered here have been<br />

carefully cleaned of dust particles by washing with distilled<br />

water. The cleaned product is then activated and sealed in<br />

glass jars. Molecular sieves are typically reactivated at a<br />

temperature of 300°C for four hours.<br />

Washed Molecular Sieves<br />

Description Qty. Part No.<br />

Washed Molecular Sieve 5A<br />

40/60 50g 5602<br />

60/80 50g 5604<br />

80/100 50g 5605<br />

100/120 50g 5606<br />

Washed Molecular Sieve 13X<br />

40/60 50g 57728<br />

60/80 50g 57730<br />

80/100 50g 57732<br />

100/120 50g 57734<br />

Stock Packed Columns<br />

6ft x 1/8" SS Packed with 80/100 Washed 5A ea 5605PC<br />

6ft x 1/8" SS Packed with 80/100 Washed 13X ea 5773PC<br />

5ft x 1/8" SS Packed with 60/80 Washed 13X ea 57730PC<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

254 www.discoverysciences.com


gas chromatography<br />

Graphitized Carbon Blacks<br />

Carbograph Packings<br />

• High speed analysis<br />

• Extremely hydrophobic—ideal for aqueous injections<br />

Equivalent to the Carbopack packings. Carbograph<br />

packings can be modified with a stationary phase giving them<br />

unique selectivities.<br />

Carbograph 1<br />

Equivalent to Carbopack B. It has a surface area of<br />

100m 2 /g. Carbograph 1-TD has a coarse mesh of 20/40<br />

which is suitable for thermal desorption work. Maximum<br />

temperature 500°C.<br />

Carbograph 1SC<br />

Similar to Carbopack BHT, specifically for the separation of<br />

sulfur compounds. It has a mesh of 40/60, and a maximum<br />

temperature of 225°C.<br />

Carbograph 2<br />

Equivalent to Carbopack C. It has a specific surface of<br />

10m 2 /g for the separation of volatile organic compounds.<br />

Carbograph 2-TD has a coarse mesh of 20/40 which<br />

is suitable for thermal desorption work. Maximum<br />

temperature 500°C.<br />

Carbograph<br />

Description Qty. Part No.<br />

Uncoated<br />

Carbograph 1-TD, 20/40, >500°C 15g 1740<br />

Carbograph 1, 60/80, >500°C 10g 1722<br />

Carbograph 1 80/120, >500°C 10g 1724<br />

Carbograph 2-TD, 20/40, >500°C 15g 1745<br />

Carbograph 2, 60/80, >500°C 10g 1726<br />

Carbograph 2, 80/100, >500°C 10g 1728<br />

Carbograph 1-SC, 40/60, 225°C 10g 1734<br />

Coated<br />

1% AT-1000 on Carbograph 1 60/80, 225°C 15g 1733<br />

0.1% AT-1000 on Carbograph 2<br />

15g 1737<br />

80/100, 225°C<br />

4% Carbowax ® 20M on Carbograph 1 DA 15g 17271<br />

80/120, 200°C<br />

0.2% Carbowax ® 1500 on Carbograph 2 15g 1725<br />

60/80, 175°C<br />

0.2% Carbowax ® 1500 on Carbograph 2 15g 1720<br />

80/100, 175°C<br />

5% Carbowax ® 20M on Carbograph<br />

15g 1729<br />

1 AW 80/120, 225°C<br />

6.6% Carbowax ® 20M on Carbograph 1 AW 15g 1731<br />

80/120, 225°C<br />

4% Carbowax ® 20M + 0.8% KOH on<br />

15g 1735<br />

Carbograph 1 60/80, 220°C<br />

0.19% Picric Acid on Carbograph 2<br />

15g 1736<br />

80/100, 120°C<br />

0.8% THEED on Carbograph 2 80/100, 125°C 15g 1942<br />

Graphpac-GC and -GB Packings<br />

• Graphitized carbon<br />

• Inert, non-specific surface<br />

• Unique separation properties<br />

• Optimized phase loading<br />

• Hydrophobic—ideal for aqueous injections<br />

Graphpac-GC has an average surface area of<br />

10–13m 2 /g, while Graphpac-GB has a larger surface area<br />

of 100–110m 2 /g. Both types interact with samples almost<br />

completely by non-specific adsorption. Which results in unique<br />

separations not achievable with fused silica open tubular<br />

(FSOT) capillary columns. Alcohols, hydrocarbons, and acids<br />

are separated in series according to carbon number.<br />

The carbons possess partitioning capabilities as uncoated<br />

packings, use stationary phases to modify the selectivity of<br />

these carbons.<br />

Graphpac<br />

Description Qty. Part No.<br />

Graphpac-GC<br />

0.1% AT-1000, 225°C, 80/100 15g 8542<br />

0.2% Carbowax ® 1500, 175°C, 80/100 15g 8546<br />

0.19% Picric Acid, 120°C, 80/100 15g 8550<br />

0.8% THEED, 125°C, 80/100 15g 8552<br />

Uncoated, 60/80 15g 8536<br />

Uncoated, 80/100 15g 8538<br />

Custom—Specify Phase and % Loading 15g C-2200<br />

Graphpac-GB<br />

1% AT-1000, 225°C, 60/80 15g 8517<br />

4% Carbowax ® 20M + 0.8% KOH Amines, 15g 8519<br />

220°C, 60/80<br />

Uncoated, 60/80 15g 8513<br />

Uncoated, Acid Washed, 60/80 15g 8533<br />

Custom—Specify Phase, Mesh, and % Loading 15g C-2200<br />

Custom, Acid Washed—Specify Phase, Mesh, 15g C-2300<br />

and % Loading<br />

Stock Packed Columns<br />

6ft x 1/8" SS Packed with 0.1% AT-1000, ea 8542PC<br />

225°C, 80/100<br />

6ft x 1/8" SS Packed with 0.2% Carbowax ® 1500, ea 8546PC<br />

175°C, 80/100<br />

7ft x 1/8" SS Packed with 0.19% Picric Acid, ea 85501PC<br />

120°C 80/100<br />

10ft x 1/8" SS Packed with 5% Krytox ® 143°C,<br />

60/80<br />

ea 85222<br />

gc columns | packed<br />

www.discoverysciences.com<br />

255


gas chromatography<br />

gc columns | packed<br />

Porous Polymers<br />

Tenax ® -TA (GC) Polymers<br />

• Stable baseline after conditioning<br />

• Short retention times<br />

• Low affinity for water<br />

• Maximum temperature limit is 350°C<br />

Tenax ® -TA is a porous polymer that is based on 2,6-Diphenylp-phenylene<br />

Oxide. It has replaced Tenax ® -GC. Tenax ® -TA<br />

can be used as a packing and as a trapping material. Both the<br />

EPA and NIOSH specify the use of Tenax ® in their standard<br />

methods. Tenax ® is particularly useful for the analysis of high<br />

boiling compounds such as alcohols, polyethylene glycols,<br />

diols, phenols, monoamines and diamines, ethanolamines,<br />

aldehydes, ketones, and chlorinated aromatics.<br />

Tenax ® -TA (GC) Specifications<br />

Specific Surface Area: 35m 2 /g<br />

Pore Volume:<br />

2.4g/cc<br />

Average Pore Size:<br />

200nm<br />

Density:<br />

0.25g/cc<br />

Tenax ® -TA (GC)<br />

Description Qty. Part No.<br />

20/35 10g 04914<br />

20/35 100g 049141<br />

20/35 500g 049142<br />

20/35 1000g 049143<br />

35/60 10g 04915<br />

35/60 100g 049151<br />

35/60 500g 049152<br />

35/60 1000g 049153<br />

60/80 10g 04916<br />

60/80 100g 049161<br />

60/80 500g 049162<br />

60/80 1000g 049163<br />

80/100 10g 04917<br />

80/100 100g 049171<br />

80/100 500g 049172<br />

80/100 1000g 049173<br />

Pretreated Tenax ® -TA<br />

Cleaned by Solvent Extraction — C-4196<br />

Stocked Packed Columns<br />

6ft x 1/8" SS Packed with Tenax ® -TA Porous ea 4900PC<br />

Polymer, 60/80<br />

6ft x 1/8" SS Packed with Tenax ® -TA Porous ea 4901PC<br />

Polymer, 80/100<br />

Tenax ® -TA — Membranes, 47mm 10 4943<br />

Tenax ® -GR Polymers<br />

• Superior properties as trapping material<br />

• Maximum temperature limit is 350°C<br />

Tenax ® -GR contains 23% graphitized carbon as an integral<br />

part of the material. This is not an admixture; the graphitized<br />

carbon is co-precipitated with the Tenax ® polymer. The<br />

resulting material gives higher breakthrough volumes for<br />

most materials, yet is less water retentive than Tenax ® -TA.<br />

When using this material for packing GC columns, better peak<br />

symmetry is observed. Surface area is 24.1m 2 /g.<br />

Tenax ® -GR<br />

Description Qty. Part No.<br />

20/35 10g 4933<br />

20/35 100g 49331<br />

20/35 500g 49332<br />

20/35 1000g 49333<br />

35/60 10g 4935<br />

35/60 100g 49351<br />

35/60 500g 49352<br />

35/60 1000g 49353<br />

60/80 10g 4937<br />

60/80 100g 49371<br />

60/80 500g 49372<br />

60/80 1000g 49373<br />

80/100 10g 4939<br />

80/100 100g 49391<br />

80/100 500g 49392<br />

80/100 1000g 49393<br />

Stocked Packed Columns<br />

6ft x 1/8" SS Packed with Tenax ® -GR Porous<br />

Polymer, 60/80<br />

ea 4937PC<br />

tech tip<br />

Conditioning<br />

We highly recommend that Tenax ® , like all other porous polymers,<br />

be preconditioned before being packed into GC columns. This<br />

removes most of the shrinkage of the polymer and minimizes the<br />

need for further conditioning. Tenax ® can be expected to shrink<br />

further in use.<br />

256 www.discoverysciences.com


gas chromatography<br />

GC Packings<br />

HayeSep ® Porous Polymer<br />

• Pre-purified porous polymers for GC<br />

• Less bleed and shrinkage than other porous polymers<br />

• Cleaned and conditioned to 200°C (165°C for N & T)<br />

HayeSep ® polymers were developed to solve room<br />

temperature separation of N2, O2, Ar and CO; ppm H2O in<br />

the presence of HCl, Cl2 etc. The HayeSep ® D series better<br />

separates the fixed gases to the C2 hydrocarbons.<br />

HayeSep ® Specifications<br />

Series Polymer Composition<br />

Surface<br />

Area Polarity<br />

Q DVB* 582m 2 /g Non-Polar<br />

P DVB*/Styrene 165m 2 /g Slightly Polar<br />

R DVB*/N-Vinyl-2-pyrrolidinone 344m 2 /g Moderately Polar<br />

S DVB*/4-Vinyl-pyridine 583m 2 /g Moderately Polar<br />

T EGDM** 250m 2 /g Very Polar<br />

N DVB*/EGDM** 405m 2 /g Very Polar<br />

A DVB*/EGDM** (high purity) 526m 2 /g Moderately Polar<br />

B DVB*/Polyethyleneimine 608m 2 /g Very Polar<br />

C DVB*/Acrylonitrile 442m 2 /g Moderately Polar<br />

D DVB* (high purity) 795m 2 /g Non-Polar<br />

*Divinylbenzene. **Ethyleneglycoldimethacrylate.<br />

Comparison of HayeSep ® “D” Formulations †<br />

Table 1—Retention Time (in minutes)<br />

Air CH4 CO2 C2H2 C2H4 C2H6 H2O<br />

DIP 0.9 1.7 3.1 5.4 5.8 8.3 9.0<br />

D 0.9 1.7 3.1 5.8 6.1 8.4 8.6<br />

DOX 1.0 1.8 3.2 5.9 6.3 8.5 8.3<br />

DB 0.9 1.6 3.1 6.1 6.6 8.7 8.1<br />

†<br />

Retention data based on 10ft x 1/8" stainless steel at 45°C, 30mL/min.<br />

HayeSep ®<br />

Description<br />

Mesh<br />

Temp. Limit<br />

max. Qty. Part No.<br />

HayeSep ® A 60/80 165°C 75cc 2818<br />

80/100 165°C 75cc 2819<br />

100/120 165°C 75cc 2820<br />

20/140 165°C 75cc 2821<br />

HayeSep ® B 60/80 190°C 75cc 2822<br />

80/100 190°C 75cc 2823<br />

100/120 190°C 75cc 2824<br />

HayeSep ® C 60/80 250°C 75cc 2825<br />

80/100 250°C 75cc 2826<br />

100/120 250°C 75cc 2827<br />

HayeSep ® D 60/80 290°C 75cc 2828<br />

80/100 290°C 75cc 2829<br />

100/120 290°C 75cc 2830<br />

HayeSep ® (continued)<br />

Description<br />

Mesh<br />

Temp. Limit<br />

max. Qty. Part No.<br />

HayeSep ® DB 60/80 290°C 75cc 2834<br />

80/100 290°C 75cc 2835<br />

100/120 290°C 75cc 2836<br />

HayeSep ® DIP 60/80 290°C 75cc 2831<br />

80/100 290°C 75cc 2832<br />

100/120 290°C 75cc 2833<br />

HayeSep ® N 60/80 165°C 75cc 2815<br />

80/100 165°C 75cc 2816<br />

100/120 165°C 75cc 2817<br />

HayeSep ® P 60/80 250°C 75cc 2803<br />

80/100 250°C 75cc 2804<br />

100/120 250°C 75cc 2805<br />

HayeSep ® Q 60/80 275°C 75cc 2800<br />

80/100 275°C 75cc 2801<br />

100/120 275°C 75cc 2802<br />

HayeSep ® R 60/80 250°C 75cc 2806<br />

80/100 250°C 75cc 2807<br />

100/120 250°C 75cc 2808<br />

HayeSep ® S 60/80 250°C 75cc 2809<br />

80/100 250°C 75cc 2810<br />

100/120 250°C 75cc 2811<br />

HayeSep ® T 60/80 165°C 75cc 2812<br />

80/100 165°C 75cc 2813<br />

100/120 165°C 75cc 2814<br />

Stock Packed Columns<br />

40ft x 1/8" SS Packed 120/140 165°C ea 28211<br />

with HayeSep ® A<br />

10ft x 1/8" SS Packed 100/120 290°C ea 28301PC<br />

with HayeSep ® D<br />

20ft x 1/8" NI Packed 100/120 290°C ea 27082PC<br />

with HayeSep ® D<br />

30ft x 1/8" SS Packed 100/120 290°C ea 27083PC<br />

with HayeSep ® D<br />

30ft x 1/8" SS Packed 100/120 290°C ea 2836PC<br />

with HayeSep ® DB<br />

9ft x 1/8" SS<br />

100/120 290°C ea 2833PC<br />

HayeSep ® DIP<br />

8ft x 1/8" SS Packed 60/80 250°C ea 2803PC<br />

with HayeSep ® P<br />

6ft x 1/8" SS Packed 80/100 250°C 75cc 2804PC<br />

with HayeSep ® P<br />

6ft x 1/8" SS Packed 80/100 275°C ea 2801PC<br />

with HayeSep ® Q<br />

8ft x 1/8" SS Packed 80/100 275°C ea 28010PC<br />

with HayeSep ® Q<br />

6ft x 1/8" SS Packed 80/100 250°C ea 2807PC<br />

with HayeSep ® R<br />

6ft x 1/8" SS Packed 100/120 250°C ea 2811PC<br />

with HayeSep ® S<br />

6ft x 1/8" SS Packed 80/100 165°C ea 2813PC<br />

with HayeSep ® T<br />

5ft x 1/8" SS Packed<br />

with HayeSep ® T<br />

100/120 165°C ea 2814PC<br />

gc columns | packed<br />

www.discoverysciences.com<br />

257


gas chromatography<br />

GC Packings<br />

Century Series Chromosorb ®<br />

Century Series Chromosorb ® porous polymers have a rigid<br />

structure and distinct pore size. They are packed into columns<br />

in the normal manner and do not require a liquid coating.<br />

We recommend preconditioning all porous polymers before<br />

packing columns.<br />

Porapak ®<br />

Porapak ® GC packings are cross-linked polymers which<br />

can be used directly in GC columns without a stationary<br />

phase coating. Acetone washing of Porapaks ® improves<br />

performance.<br />

Chromosorb ® Specifications<br />

Series Polymer Composition Surface Area Polarity<br />

101 DVB*/Styrene >50m 2 /g Non-Polar<br />

102 DVB*/Styrene 300–400m 2 /g Slightly Polar<br />

103 Cross-linked Polystyrene** 15–25m 2 /g Non-Polar<br />

105 Polyaromatic 600–700m 2 /g Mod. Polar<br />

106 Cross-linked Polystyrene 700–800m 2 /g Non-Polar<br />

107 Cross-linked Acrylic Ester 400–500m 2 /g Polar<br />

108 Cross-linked Acrylic 100–200m 2 /g Polar<br />

*Divinylbenzene. **The surface is basic.<br />

Porapak ® Specifications<br />

Series Polymer Composition Surface Area Polarity<br />

Q DVB*/Ethylvinylbenzene 500–600m 2 /g Slightly Polar<br />

P DVB*/Styrene 100–200m 2 /g Non-Polar<br />

R DVB*/Vinyl pyrrolidinone 450–600m 2 /g Mod. Polar<br />

S DVB*/Vinyl pyridine 300–450m 2 /g Mod. Polar<br />

T EGDM** 225–350m 2 /g Polar<br />

N DVB*/Vinyl pyrrolidinone 250–350m 2 /g Very Polar<br />

*Divinylbenzene. **Ethyleneglycoldimethacrylate.<br />

gc columns | packed<br />

Chromosorb ®<br />

Description<br />

Mesh<br />

Temp. Limit*<br />

max. Qty. Part No.<br />

Chromosorb ® 101 60/80 275/325°C 50g 2405<br />

80/100 275/325°C 50g 2406<br />

100/120 275/325°C 50g 2407<br />

Chromosorb ® 102 60/80 250/300°C 50g 2408<br />

80/100 250/300°C 50g 2409<br />

100/120 250/300°C 50g 2410<br />

Chromosorb ® 103 60/80 250/300°C 50g 2411<br />

80/100 250/300°C 50g 2412<br />

100/120 250/300°C 50g 2413<br />

Chromosorb ® 105 60/80 250/275°C 50g 2417<br />

80/100 250/275°C 50g 2418<br />

100/120 250/275°C 50g 2419<br />

Chromosorb ® 106, 60/80 250/275°C 50g 2420<br />

80/100 250/275°C 50g 2421<br />

100/120 250/275°C 50g 2422<br />

Chromosorb ® 107 60/80 250/275°C 50g 2423<br />

80/100 250/275°C 50g 2424<br />

100/120 250/275°C 50g 2425<br />

Chromosorb ® 108 60/80 250/275°C 50g 2426<br />

80/100 250/275°C 50g 2427<br />

100/120 250/275°C 50g 2428<br />

Preconditioning Service † per bottle C-14030<br />

†<br />

Specify bulk packing part no. and preconditioning service part no.<br />

*Isothermal/Temp. program.<br />

Porapak ®<br />

Description<br />

Mesh<br />

Temp. Limit<br />

max. Qty. Part No.<br />

Porapak ® Q 50/80 250°C 26g 2700<br />

80/100 250°C 26g 2701<br />

100/120 250°C 26g 2702<br />

Porapak ® P 50/80 250°C 20g 2703<br />

80/100 250°C 20g 2704<br />

100/120 250°C 20g 2705<br />

Porapak ® R 50/80 250°C 24g 2706<br />

80/100 250°C 24g 2707<br />

100/120 250°C 24g 2708<br />

Porapak ® S 50/80 250°C 26g 2709<br />

80/100 250°C 26g 2710<br />

100/120 250°C 26g 2711<br />

Porapak ® T 50/80 190°C 31g 2712<br />

80/100 190°C 31g 2713<br />

100/120 190°C 31g 2714<br />

Porapak ® N 50/80 190°C 29g 2715<br />

80/100 190°C 29g 2716<br />

100/120 190°C 29g 2717<br />

Porapak ® PS 50/80 250°C 20g 2721<br />

80/100 250°C 20g 2722<br />

100/120 250°C 20g 2723<br />

Acetone Washing Service † per bottle C-2700<br />

†<br />

Specify bulk packing part no. in addition to acetone washing part no.<br />

tech tip<br />

Temperature limits<br />

Our GC capillary columns are temperature rated. In some cases,<br />

we list two maximum operating temperatures, the lower one is<br />

for isothermal condition and the higher one for temperatureprogrammed<br />

condition.<br />

258 www.discoverysciences.com


gas chromatography<br />

Capillary Connectors<br />

Universal Capillary Connectors<br />

• One size fits tubing from 0.25mm i.d. to 0.53mm i.d.<br />

• Available in straight or Y configurations<br />

Capillary connectors form a gas-tight seal when heated to<br />

typical GC temperatures. The angled connectors conform<br />

to the curvature of a fused silica capillary column. To create<br />

a permanent seal, add a small amount of polyimide resin to<br />

the outside of the capillary tube before inserting. Order under<br />

“Accessories” below.<br />

Universal Straight Connector<br />

0017<br />

Featherweight Capillary Union<br />

• Lightweight<br />

• High temperature Vespel ®<br />

construction<br />

• Accommodates all tubing sizes<br />

Featherweight Capillary Union<br />

Description<br />

Part No.<br />

Featherweight Union with 2 Nuts* 28990<br />

Vespel ® Ferrules for Use with Featherweight Union<br />

Vespel ® Ferrule, 0.8mm i.d. 28992<br />

Vespel ® Ferrule, 0.5mm i.d. 28993<br />

Vespel ® Ferrule, 0.4mm i.d. 28994<br />

*Order ferrules separately.<br />

5717<br />

Connectors<br />

Description Qty. Part No.<br />

Straight Connectors<br />

Fused Silica<br />

Universal Straight Connector 5 20400<br />

Universal Straight Connector 25 20401<br />

Angled Universal Connector 5 20694<br />

Angled Universal Connector 25 20695<br />

Borosilicate<br />

Universal Straight Connector 5 20490<br />

Universal Straight Connector 25 20492<br />

Y-Connectors<br />

Fused Silica<br />

Universal Y-Connector 1 20405<br />

Angled Universal Y-Connector 1 20500<br />

Borosilicate<br />

Universal Y-Connector 1 20480<br />

Universal Y-Connector 5 20482<br />

Accessories<br />

Polyimide Sealing Resin 5g 5825<br />

Fused Silica Outlet Splitters<br />

• Accommodates capillaries<br />

from 0.22 to 0.32mm i.d.<br />

and provides a 1:1 ratio<br />

• Includes a glass-lined SS<br />

bulkhead union, a 0.4mm i.d.<br />

two-hole Vespel ® graphite<br />

ferrule and two lengths of<br />

deactivated fused silica tubing<br />

Use this inert outlet splitter with two detectors or one detector<br />

and a sample collection device.<br />

Outlet Splitter<br />

Description<br />

Part No.<br />

Outlet Splitter 14898<br />

6628<br />

gc accessories | capillary<br />

Valco ® Zero-Dead Volume Union<br />

Use these stainless steel unions to make connections with fused silica capillaries.<br />

Unions feature specially designed Vespel ® /graphite ferrules and are bored through.<br />

Table 1 shows the parts needed for different connections.<br />

6021<br />

Table 1<br />

Connect From: to 0.25mm i.d. Fused Silica to 0.32mm i.d. Fused Silica to 0.53mm i.d. Fused Silica to 1/16" SS Tubing<br />

0.25mm i.d. Fused Silica 9068 9068 + 907110 45849 + 907010 + 903410 45849 + 907010<br />

0.32mm i.d. Fused Silica 9069 + 907010 9069 45849 + 907110 + 903410 45849 + 907110<br />

0.53mm i.d. Fused Silica 45849 + 907010 + 903410 45849 + 907110 + 903410 9031 45835 + 903410<br />

1/16" SS Tubing 45849 + 907010 45849 + 907110 45835 + 903410 45835<br />

Valco ® Zero-Dead Volume Unions<br />

Description and Valco ® No.<br />

Part No.<br />

Zero Dead-Volume Unions<br />

1/32", 0.4mm (Valco ® ZU.5TFS.4) 9068<br />

1/32", 0.5mm (Valco ® ZU.5TFS.5) 9069<br />

1/16", 0.8mm (Valco ® ZU1TFS.8) 9031<br />

1/16"–1/32", 1/32" Bore (Valco ® ZRU1.5T) 45849*<br />

1/16", 1/16" Bore (Valco ® ZU1T) 45835*<br />

Valco ® Reducing Ferrules<br />

Description and Valco ® No.<br />

Part No.<br />

Valco ® Reducing Ferrules*<br />

1/32" to 0.4mm (Valco ® FS.4), 10/pk 907010<br />

1/32" to 0.5mm (Valco ® FS.5), 10/pk 907110<br />

1/16" to 0.8mm (Valco ® FS1.8), 10/pk 903410<br />

*Includes 2 stainless steel ferrules.<br />

www.discoverysciences.com<br />

259


gas chromatography<br />

gc accessories | capillary<br />

Capillary Guards and Tubing<br />

Universal Guard Column Kits<br />

• Universal kits connect<br />

to any capillary<br />

column<br />

• Guard columns are<br />

deactivated<br />

Universal guard column kits contain three 5m deactivated<br />

capillaries, three-universal fused silica connectors, ceramic<br />

cutter, and instructions. Order sealing resin separately under<br />

“Accessories” to reinforce connections. Replacement kit parts<br />

are available below.<br />

Universal Guard Column kits<br />

Description<br />

Part No.<br />

Universal Guard Column Kits<br />

0.53mm Universal Guard Column Kit 13992<br />

0.32mm Universal Guard Column Kit 13998<br />

0.25mm Universal Guard Column Kit 14005<br />

Replacement Parts<br />

Universal Connectors, 5/pk 20400<br />

Angled Universal Connector, 5/pk 20694<br />

5m x 0.53mm i.d. Capillaries, 5/pk 13990<br />

5m x 0.32mm i.d. Capillaries, 5/pk 13999<br />

5m x 0.25mm i.d. Capillaries, 5/pk 14007<br />

Accessories<br />

Polyimide Sealing Resin, 5g 5825<br />

20X Magnifier 3163<br />

Deactivated Guard Columns<br />

• Three different deactivation<br />

polarities<br />

• Chemically inert<br />

These guard columns protect<br />

your analytical column by<br />

collecting non-volatile, pyrolyzable,<br />

or particulate contamination.<br />

Deactivated Guard Columns<br />

Description<br />

Part No.<br />

Non-Polar<br />

0.25mm x 5m 19063<br />

0.32mm x 5m 19064<br />

0.53mm x 5m 19065<br />

Intermediate Polar<br />

0.25mm x 5m 19054<br />

0.32mm x 5m 19055<br />

0.53mm x 5m 19056<br />

Polar<br />

0.25mm x 5m 19057<br />

0.32mm x 5m 19058<br />

0.53mm x 5m 19059<br />

6630<br />

6624<br />

Fused Silica Capillary Tubing<br />

• Deactivated and<br />

undeactivated tubing<br />

available<br />

• Available mounted on<br />

a cage<br />

Alltech provides the finest<br />

quality fused silica capillary<br />

tubing either untreated or<br />

deactivated by our proprietary<br />

high temperature process. Use<br />

tubing to prepare your own<br />

capillaries or guard columns.<br />

Fused Silica Capillary Tubing<br />

i.d. Qty. Length Part No.<br />

Deactivated Tubing with Cage<br />

0.18mm — 10m 602026<br />

0.18mm — 20m 602028<br />

0.18mm — 40m 602029<br />

0.25mm — 15m 602915<br />

0.25mm — 30m 602930<br />

0.25mm — 60m 602960<br />

0.32mm — 15m 603915<br />

0.32mm — 30m 603930<br />

0.32mm — 60m 603960<br />

0.45mm — 15m 602030<br />

0.45mm — 30m 602032<br />

0.45mm — 60m 602034<br />

0.53mm — 15m 605915<br />

0.53mm — 30m 605930<br />

0.53mm — 60m 605960<br />

Deactivated Tubing, Without Cage<br />

0.05mm — per meter 602038<br />

0.10mm — per meter 602037<br />

0.18mm — per meter 602010<br />

0.25mm — per meter 602640<br />

0.25mm x 1m 5/pk — 5827<br />

0.25mm x 2m 5/pk — 5829<br />

0.32mm — per meter 603640<br />

0.32mm x 1m 5/pk — 5831<br />

0.32mm x 2m 5/pk — 5833<br />

0.45mm — per meter 602012<br />

0.53mm — per meter 605640<br />

0.53mm x 1m 5/pk — 5832<br />

0.53mm x 2m 5/pk — 5834<br />

Undeactivated Tubing, Without Cage<br />

0.05mm — per meter 602035<br />

0.10mm — per meter 602036<br />

0.18mm — per meter 19603<br />

0.25mm — per meter 602600<br />

0.32mm — per meter 603600<br />

0.45mm — per meter 19602<br />

0.53mm — per meter 605600<br />

6631<br />

260 www.discoverysciences.com


gas chromatography<br />

Capillary Accessories<br />

Capillary Cages<br />

These cages are made of a heavy<br />

gauge stainless steel and are<br />

electropolished to prevent abrasion.<br />

All are 7 inches in diameter.<br />

5715<br />

Capillary Endcaps<br />

Increase column life by preventing contaminants<br />

from entering column during storage.<br />

Capillary Cages<br />

Description<br />

Part No.<br />

7" x 3/4" Cage 75200<br />

7" x 1-1/4" Cage 75201<br />

7" x 1-3/4" Cage 75202<br />

High Temperature String, 10ft 6344<br />

Capillary Column Washer<br />

This easy to use column washer is designed for<br />

solvent flushing of bonded or cross-linked fused silica<br />

capillaries. It is made of heavy-duty glass and will<br />

hold up to 20mL of solvent. Maximum pressure is<br />

125psig. Order appropriate sized ferrules separately<br />

below.<br />

Capillary Column Washer<br />

Description Qty. Part No.<br />

Capillary Column Washer ea 5819<br />

Ferrules<br />

1/8" to 0.4mm VG1 10 200/0.4-VG1<br />

1/8" to 0.5mm VG1 10 200/0.5-VG1<br />

1/8" to 0.8mm VG1 10 200/0.8-VG1<br />

tech tip<br />

How much solvent is needed to wash your column?<br />

Refer to the table below.<br />

Approximate Column Volume Required<br />

Length 0.25mm i.d. 0.32mm i.d. 0.53mm i.d.<br />

10m 0.5mL 0.8mL 2.2mL<br />

15m 0.7mL 1.2mL 3.3mL<br />

25m 1.2mL 2.0mL 5.5mL<br />

30m 1.5mL 2.4mL 6.6mL<br />

50m 2.5mL 4.0mL 11.0mL<br />

60m 2.9mL 4.8mL 13.2mL<br />

5719<br />

Capillary Endcaps<br />

Description Qty. Part No.<br />

Fused Silica 2 20699<br />

Fused Silica 20 20701<br />

Silicone 10 4018<br />

Split-Vent Trap Kit<br />

• Charcoal filter cartridges are<br />

economical and easy to replace<br />

• Adsorbs toxic vapors<br />

• Connects directly to Agilent GCs<br />

Alltech’s split-vent trap kit effectively adsorbs toxic or<br />

noxious vapors that might otherwise be released into<br />

the workplace. The trap has a 1/8" fitting to connect<br />

directly to Agilent GCs and can be adapted for use<br />

with most other GCs.<br />

The split-vent trap features a corrosion-resistant<br />

base and a disposable NIOSH-type charcoal filter<br />

cartridge that is easy to replace. Order replacement<br />

cartridges below.<br />

What’s included: split-vent trap, three charcoal<br />

cartridges, cartridge scorer, and tip breaker.<br />

Split-Vent Trap Kit<br />

Description<br />

Part No.<br />

Split-Vent Trap Kit 5870<br />

Replacement Charcoal Cartridge, 10/pk 5872<br />

1/8" Stainless Steel Union 14165<br />

6632<br />

5702<br />

gc accessories | capillary<br />

www.discoverysciences.com<br />

261


gas chromatography<br />

gc accessories | packed<br />

Packing Accessories<br />

Attachable Funnel<br />

This anodized aluminum funnel attaches<br />

easily to 1/8" and 1/4" o.d. glass and metal<br />

tubing—ideal for column packing. Funnel<br />

can be disassembled for cleaning. Order<br />

adapters separately to attach funnel to<br />

columns with fittings already connected.<br />

Replacement o-rings are also available below.<br />

Attachable Funnel<br />

Description<br />

Part No.<br />

Attachable Funnel 4008<br />

Adapters<br />

for 1/8" Column 4050<br />

for 3/16" Column 4052<br />

for 1/4" Column 4054<br />

for 3/8" Column 4056<br />

Replacement O-rings, 12/pk 4010<br />

GC Column Vibrator<br />

This vibrator is ideal for use when filling GC<br />

columns, including glass columns. This two-speed<br />

unit comes supplied with a 7-foot cord and U.S.<br />

standard plug.<br />

GC Column Vibrator<br />

Description<br />

Part No.<br />

110V 4012<br />

Delrin ® Plugs<br />

• Use these plugs to seal the ends<br />

of columns<br />

Simply slip plug into your ferrule and nut,<br />

and attach to your fittings. Ferrules will not<br />

lock in place. Plugs are reusable.<br />

Delrin ® Plugs<br />

Size Qty. Part No.<br />

1/16" 25 2898<br />

1/8" 25 2900<br />

1/4" 25 2902<br />

5079<br />

6660<br />

5087<br />

Premium Glass Wool<br />

Untreated—A soft fine denier Pyrex ® wool,<br />

primarily used for non-chromatographic<br />

applications.<br />

Silane Treated—Fine wool treated with<br />

di-methyldichlorosilane (DMDCS) to yield an inert<br />

material that won't decompose sensitive compounds.<br />

This material is ideal for most chromatographic applications.<br />

Phosphoric Acid (H3PO4), Treated—For analysis of acidic<br />

compounds such as free acids, phenols, and glycols.<br />

Quartz Wool—Made from high-purity quartz, extremely low<br />

in metallic oxide impurities.<br />

PTFE Wool—Commonly used as a plug for packed columns<br />

when analyzing for low levels of sulfur.<br />

Pesticide Grade Glass Wool—A superbly inert glass wool<br />

ideal for use with electron capture, nitrogen-phosphorous,<br />

flame photometric, alkali-bead flame, and all electrolytic<br />

detectors.<br />

Glass Wool Tools<br />

Glass Wool Inserter/Remover<br />

Wool Inserter<br />

Premium Glass Wool<br />

Description Qty. Part No.<br />

Glass Wool<br />

Untreated Glass Wool 50g 4035<br />

Silane-Treated Glass Wool 50g 4037<br />

Silane-Treated Glass Wool 250g 4038<br />

Phosphoric Acid-Treated Glass Wool 25g 4039<br />

Quartz Wool 10g 4033<br />

Silane-Treated Quartz Wool 10g 4233<br />

PTFE Wool 10g 4736<br />

Pesticide-Grade Glass Wool 10g 4034<br />

Glass Wool Tools<br />

Glass Wool Inserter/Remover 2 6292<br />

Wool Inserter ea 6285<br />

5075<br />

5088<br />

5089<br />

262 www.discoverysciences.com


gas chromatography<br />

Packing Accessories<br />

GC End Caps<br />

These end caps are non-shredding,<br />

flexible, and easily applied and removed.<br />

They provide a positive barrier to moisture<br />

and air. The 5/16" size fits over 1/4"<br />

columns that have ferrules swaged on the ends.<br />

The 3/16" size fits 1/8" columns with ferrules in place.<br />

GC End Caps<br />

Tube o.d. Qty. Part No.<br />

1/16" 100 4020<br />

1/8" 100 4021<br />

3/16" 100 4022<br />

1/4" 100 4023<br />

5/16" 100 4025<br />

3/8" 100 4024<br />

Glass Column Repair Kits<br />

This repair kit includes a 1ft (30.5cm)<br />

piece of shrinkable TFE-FEP tubing that<br />

encapsulates the broken section creating<br />

a tight and reliable seal.<br />

Easy to apply, just slip over one end of the<br />

broken tubes, butt the tubes, and heat to<br />

330°C with a heat gun.<br />

Glass Column Repair Kits<br />

Tubing Size<br />

Part No.<br />

Glass Column Repair Kits<br />

Up to 0.036" (0.91mm) 5800<br />

Up to 0.060" (1.52mm) 5801<br />

Up to 0.130" (3.30mm) 5802<br />

0.125" (3.18mm) to 0.250" (6.35mm) 5803<br />

Heat Gun<br />

110V 2518<br />

220V 2518-220V<br />

Column Tags<br />

Use these aluminum tags to create<br />

a permanent heat resistant record of<br />

pertinent column information. Writing<br />

surface of tag is 1" x 2" (25.4 x 50.8mm).<br />

Column Tags<br />

Description Qty. Part No.<br />

Embossed GC Tags 100 8011<br />

Embossed GC Tags 25 8012<br />

Embossed LC Tags 25 8005<br />

Plain Tags 100 8009<br />

5085<br />

5082<br />

5074<br />

Pressed Frits<br />

These frits are precision-fabricated<br />

from Type 316 stainless steel and<br />

are ideal for sealing the ends of<br />

GC columns.<br />

Pressed frits are easy to install.<br />

Drill the column ends to the proper<br />

diameter and depth using the drill<br />

bits sold below. Rest the frit on<br />

top of the tubing and gently tap<br />

it into place.<br />

Drill Bits<br />

These drill bits are specifically<br />

designed to prepare tubing for frit<br />

installation. They include a bushing that<br />

acts as a stop to control the depth of the hole.<br />

Vibrograver<br />

Use for engraving or column<br />

packing. A carbide point is<br />

included. Remove the point to<br />

use for column packing. Order<br />

replacements below. Vibrograver<br />

is not CE marked.<br />

Pressed<br />

Frits<br />

Column<br />

Stainless Steel Pressed Frits<br />

Pore Diameter Qty. For Use With 1/8" o.d. Tubing For Use with 1/4" o.d. Tubing<br />

0.5µm 25 702625 —<br />

2.0µm 25 703425 703525<br />

5.0µm 25 702825 702925<br />

10.0µm 25 703025 703125<br />

20.0µm 25 703225 703325<br />

Drill Bits<br />

Diameter Qty. Part No.<br />

for 1/8" Frits ea 7032<br />

for 1/4" Frits ea 7033<br />

Vibrograver<br />

Description<br />

Part No.<br />

Vibrograver<br />

110V 8006<br />

220V 8018<br />

Replacement Point<br />

Diamond 15044<br />

Carbide 15045<br />

5086<br />

1050<br />

6633<br />

5076<br />

gc accessories | packed<br />

www.discoverysciences.com<br />

263


gas chromatography<br />

Cylinder Accessories<br />

Cylinder Status Tags<br />

Flow Controllers<br />

Flow Diverter<br />

Cylinder status tags help to organize and<br />

positively identify cylinders.<br />

Cylinder Status Tags<br />

Description<br />

Part No.<br />

Cylinder Status Tags, 25/pk 8004<br />

Cylinder Tools<br />

5250<br />

Easily divert the gas stream from<br />

your detector to your soapfilm<br />

flowmeter. One Flow Diverter<br />

is required for each gas. It is<br />

supplied with 1/8" fittings.<br />

Flow Diverter<br />

Description<br />

Part No.<br />

Flow Diverter 4200<br />

5226<br />

Conveniently open valves, tighten gauges, connections,<br />

regulators, etc.<br />

Adjustable Flow Controller<br />

• Control flow rates from 0.5mL/min up to<br />

1.6L/min<br />

gc accessories | gas flow<br />

Cylinder Holders<br />

Prevent toppling of<br />

cylinders with these<br />

cast aluminum cylinder<br />

holders. Holders feature<br />

a nylon web strap with a<br />

sturdy buckle. Cylinder<br />

holders handle cylinders<br />

from 4 to 15 inches in<br />

diameter. Choose from<br />

benchtop or wall mount<br />

styles.<br />

6777<br />

Cylinder Valve & Cap Wrench<br />

Matheson Switchover Systems<br />

• Automatically change cylinders<br />

• Compact design minimizes wall<br />

space consumption<br />

9-way Cylinder Wrench<br />

Cylinder Tools<br />

Description<br />

Part No.<br />

Cylinder Valve & Cap Wrench 37135<br />

9-Way Cylinder Wrench 412933<br />

Wall mount cylinder holder<br />

with safety strap<br />

Cylinder Holders<br />

Description<br />

Part No.<br />

Bench Top Model with Cylinder Strap 37132<br />

Wall Mount Model with Cylinder Strap 37133<br />

5178<br />

6098<br />

This adjustable flow controller features a user<br />

variable span adjustment permitting it to be<br />

used for a variety of flow ranges. Use the<br />

ten-turn knob to easily adjust flow rates from<br />

zero to maximum. Pipe adapters for 1/8" o.d.<br />

tubing are included.<br />

Flow Controller Specifications<br />

Flow Rate:<br />

Adjustable from 1.6mL/min to 0.5L/min<br />

Body:<br />

Aluminum<br />

Diaphragm: Stainless Steel<br />

Max Pressure: 250psig<br />

Max Temp: 120°C<br />

Ports:<br />

1/8" MPT<br />

Flow Controller<br />

Description<br />

Part No.<br />

Adjustable Flow Controller 8149<br />

Eco-Mizer<br />

• Conserve expensive gases during<br />

standby periods<br />

• Decrease laboratory operating expenses<br />

• Directly connects to 1/8" o.d. tubing<br />

The Eco-Mizer is a compact standby valve<br />

designed to conserve gases overnight and<br />

during other non-use periods. The adjustable<br />

fine metering valve sets the standby flow rate and a<br />

concentric, independent valve allows selection of either<br />

standby flow rate or straight-through flow.<br />

5227<br />

5251<br />

Matheson Switchover Systems<br />

Description<br />

Part No.<br />

Model 5234 Brass 37139<br />

Model 5244 SS 37143<br />

Model 5230 Brass with Regulator 37138<br />

Model 5240 SS with Regulator 37141<br />

6094<br />

Eco-Mizer<br />

Description<br />

Part No.<br />

Eco-Mizer 7070<br />

264 www.discoverysciences.com


gas chromatography<br />

Flowmeters<br />

Aalborg Single-Tube Variable Area<br />

Flowmeters<br />

• Built-in needle valve controls flow<br />

• Magnifier lens enhances reading resolution<br />

• Ideal for panel mounting<br />

Equipped with easy to change flowtubes and a<br />

control valve. Order a bench stand and fittings<br />

separately under “Accessories” below.<br />

Single-Tube Flowmeter Specifications<br />

Accuracy:<br />

±5% full scale<br />

Repeatability: ±0.25%<br />

Max Pressure: 200psig<br />

Max Temperature: 121°C<br />

Connections: 1/8" FPT inlet and outlet<br />

5198<br />

Aalborg Three-Tube Variable Area Flowmeter<br />

• Measure hydrogen, air, and carrier gases<br />

with one meter<br />

• Direct reading for hydrogen and air<br />

• Carrier gas tube can be correlated for<br />

any gas<br />

• Can be panel-mounted or free standing<br />

• Ideal for use with flame ionization detectors<br />

Three-Tube Flowmeter Specifications<br />

Accuracy:<br />

±5% full scale<br />

Repeatability: ±0.25%<br />

Max Pressure: 200psig<br />

Max Temperature: 121°C<br />

Connections: 1/8" FPT inlet and outlet<br />

5197<br />

Single-Tube Flowmeters<br />

Flowtube Range Div. Part No.<br />

65mm Flowtubes, Direct Reading Scale<br />

Helium 0–120cc/min 5mL 7900<br />

Hydrogen 0–100cc/min 5mL 7902<br />

Nitrogen 0–120cc/min 5mL 7904<br />

Air 0–1.15L/min 0.05L 7906<br />

General Purpose 0–2L/min (air) 1mm 7908<br />

Accessories<br />

Bench Mount for Above Flowmeters 7920<br />

1/8" to 1/8" MPT Brass Connector 60038<br />

1/4" to 1/8" MPT Brass Connector 60042<br />

Need Help Timing Your Flowmeter?<br />

Lightweight Stopwatch<br />

This stopwatch counts up to 24 hours with<br />

0.01sec readout and has split interval function,<br />

alarm clock with a choice of 12- or 24-hour<br />

format, a calendar displaying date and day<br />

of the week, hourly chime option, and button<br />

cell battery.<br />

Large Display Stopwatch<br />

This stopwatch features a large, 1/2" LCD<br />

display. It counts with a resolution of 0.01sec<br />

and has split interval, clock and calendar<br />

functions. It includes a rugged ABS plastic clip,<br />

neck cord, leatherette case, stand clip, and a<br />

1.5V battery.<br />

Three-Tube Flowmeter<br />

Description<br />

Part No.<br />

Three-Tube Flowmeter 4040<br />

Soapfilm Flowmeter<br />

Economical Flow Measurement<br />

This soapfilm flowmeter is easy to use. Simply time the<br />

movement of a soap bubble between two calibration<br />

marks. Alltech’s soapfilm flowmeters have a unique<br />

bubble burster at the top to eliminate the overflow of<br />

the soap solution. A rubber bulb is included with each<br />

soapfilm flowmeter. The 100µL and 500µL flowmeters<br />

are complete with stand and tubing. Order soapfilm<br />

solution and tubing under “Accessories” below.<br />

Soapfilm Flowmeters<br />

Description<br />

Part No.<br />

Flowmeters<br />

100µL 14184<br />

500µL 14185<br />

1cc 4041<br />

10cc 4042<br />

25cc 4043<br />

100cc 4045<br />

1000cc 4047<br />

Accessories<br />

Soapfilm Solution, 8oz 2040<br />

5/16" o.d. Tygon ® Tubing, 10ft 4333<br />

5195<br />

gc accessories | gas flow<br />

Triple Timer<br />

This timer features a large easy-to-read<br />

display. It can time three activities at once and<br />

has three distinctive alarms. It has a compact<br />

size of 3" x 3".<br />

Stopwatches<br />

Description<br />

Part No.<br />

Lightweight Stopwatch 4069<br />

Large Display Stopwatch 4071<br />

West Bend Triple Timer 40032<br />

related products<br />

Need a leak detector?<br />

Ensure leak-free installation of your gas<br />

purifiers. See page 267 for gas leak<br />

detectors.<br />

www.discoverysciences.com<br />

265


gas chromatography<br />

Alltech ® Regulators<br />

A) Dual-Stage Economy Regulators<br />

These regulators are suitable for pressure<br />

control of general purpose laboratory gases<br />

with applications requiring constant pressure<br />

control and delivery regardless of supply<br />

pressure variations. Typical applications<br />

include purging, pressure testing,<br />

blanketing, and chamber pressurization.<br />

Dual-Stage Economy<br />

Description CGA No. Part No.<br />

H2, Ar/Methane 350 8101<br />

O2 540 8102<br />

He, N2, Ar, Ne 580 8103<br />

Air 590 8104<br />

Air, Breathing Quality 346 8105<br />

C) Single-Stage Regulators<br />

These regulators are suitable for secondary<br />

pressure control of non-corrosive, high-purity<br />

gases or as point of use pressure control in<br />

high-purity gas distribution systems. Typical<br />

applications include point of use laboratory<br />

systems, gas supply purging, and bulk gas<br />

distribution systems.<br />

5244 5246<br />

Single Stage<br />

Description CGA No. Part No.<br />

0–40psig (delivery pressure) — 81890<br />

0–120psig (delivery pressure) — 81891<br />

0–200psig (delivery pressure) — 81892<br />

gc accessories | gas flow<br />

B) Dual-Stage<br />

High-Purity Regulators<br />

These regulators are suitable for secondary<br />

pressure control of non-corrosive or high<br />

purity gases for applications requiring<br />

constant pressure control and delivery<br />

regardless of supply pressure variations. Typical applications<br />

include gas supply purging, gas system charging, fuel gas<br />

supply control, and calibrations gas control.<br />

Dual-Stage High-Purity<br />

Description CGA No. Part No.<br />

H2, Ar/Methane 350 8109<br />

He, N2, Ar, Ne 580 8111<br />

related products<br />

Need cylinder accesories?<br />

See page 264 for more information.<br />

best<br />

seller<br />

5245<br />

D) Panel Mount Regulators<br />

These regulators can also be used in-line.<br />

Order gauges and mounting nut separately.<br />

Panel Mount<br />

Description CGA No. Part No.<br />

Panel Mount Regulator — 81896<br />

Panel Mounting Nut — 81895<br />

Pressure Gauges for Panel Mount Regulators<br />

0–30psig — 86800<br />

0–60psig — 86802<br />

0–100psig — 86804<br />

0–200psig — 86808<br />

5248<br />

Alltech ® Regulators Specifications<br />

A) Dual-Stage Economy B) Dual-Stage High-Purity C) Single Stage D) Panel Mount<br />

Body: Forged Brass Chrome-plated forged brass Chrome-plated forged brass Brass<br />

Bonnet: Brass-plated die cast zinc Chrome-plated die cast zinc Chrome-plated die cast zinc Acetal Resin<br />

Diaphragm: PTFE-lined neoprene 316L Stainless Steel 316L Stainless Steel Nitrile<br />

Seat and Internal Seal: PTFE PTFE PTFE Acetal Resin<br />

Max. Inlet Pressure: 3000psig (210 bar) 3000psig (210 bar) 3000psig (210 bar) 400psig<br />

Delivery Pres. Range: 0–120psig 0–120psig 0–40, 0–120, or 0–200psig —<br />

Delivery Pres. Gauge: 0–20psig 0–200psig 0–60, 0–200, or 0–400psig Order Separately<br />

Cylinder Pres. Gauge: 0–4000 psig 0–4000psig 0–4000psig 0–4000psig<br />

Temperature Range: -40 to 60°C -40 to 60°C -40 to 60°C -34 to 65°C<br />

Gauges: 2-1/2" diameter brass 2-1/2" diameter brass 2-1/2" diameter brass Order Separately<br />

Ports: 1/4" FPT 1/4" FPT 1/4" FPT 1/8" FPT<br />

266 www.discoverysciences.com


gas chromatography<br />

Gas Leak Detection<br />

Alltech ® Helium Leak Detector<br />

Designed Specifically to Detect Helium<br />

Gas Leaks<br />

• Portable—operates up to<br />

6.5 hours fully charged<br />

• Visual and audible detection<br />

indicators<br />

• Change polarity setting to detect<br />

other gases<br />

best<br />

seller<br />

The Alltech ® Helium Leak Detector is perfect for detecting<br />

gas leaks in GC, GC/MS, and purge/trap systems. Leaks are<br />

detected via a thermal conductivity cell and indicated visually<br />

on the LCD display and by an audible alarm. The long, flexible<br />

probe makes it convenient to detect small and hard to reach<br />

gas leaks. Use the detector for gases other than helium<br />

by simply changing the polarity setting. Detector features<br />

a simple one-step zero adjustment and is fully portable<br />

operating on rechargeable Ni-Cd batteries.<br />

What’s included: probe, rechargeable batteries and charger<br />

Helium Leak Detector Specifications<br />

Detector:<br />

Thermal conductivity cell with thermistors<br />

Sensitivity: 0.01mL/min for Helium<br />

Ambient Temp: 10 to 35°C<br />

Display:<br />

LCD indicator lights<br />

Zero Function: Yes<br />

Audible Signal: Yes<br />

Battery Life: 6.5 hours continuous fully charged<br />

Dimensions: 1.6" H x 2.9" W x 6.3" L<br />

(4.064cm H x 7.366cm W x 16.002cm L)<br />

Weight:<br />

1lb (0.454kg)<br />

Note: The Alltech ® helium leak detector is not explosion-proof and should<br />

not be used to detect combustible or corrosive gas leaks.<br />

6711<br />

Leak-Tec ® High Temp Testing Solution<br />

Temperature Range is 210 to 415°F<br />

This testing solution wets and spreads evenly and<br />

quickly responding to small leaks. Leak-Tec ® is<br />

non-corrosive and residue free. Convenient aerosol<br />

can allows spray to be directed in tight spaces.<br />

Leak-Tec ®<br />

Description Qty. Part No.<br />

Leak-Tec ® , 10oz ea 2027<br />

6 2028<br />

Leak-Check Testing Solution<br />

Leak-Check is non-toxic, non-flammable, chloridefree<br />

and dries cleanly leaving no residue behind.<br />

Temperature range is 30 to 200°F. Bottle includes<br />

a 15" snorkel tube allowing for easy access to<br />

hard-to-reach spaces.<br />

Leak-Check<br />

Description Qty. Part No.<br />

Leak-Check, 8oz ea 2025<br />

12 2026<br />

5241<br />

5242<br />

gc accessories | gas flow<br />

Helium Leak Detector<br />

Description<br />

Part No.<br />

120 VAC charger with rechargeable Ni-Cd batteries 60229<br />

220 VAC charger with rechargeable Ni-Cd batteries 60231<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

www.discoverysciences.com<br />

267


gas chromatography<br />

Gas Purifiers and Traps<br />

Why Use Gas Purifiers?<br />

A clean gas stream helps guarantee the quality of your GC<br />

analysis and the reliability of your results. It also helps prolong<br />

column life and minimize detector noise. Gas purifiers act<br />

as an insurance policy, protecting your instrumentation and<br />

analytical columns from these contaminants. They will not<br />

however, convert low purity gas into ultra high purity gas.<br />

<strong>Grace</strong> carries a variety of gas purifiers in two different styles.<br />

See Table 1 for details.<br />

Choosing the Right Gas Purifier for Your<br />

Application<br />

There are a variety of gas purifiers available. Some remove<br />

a specific contaminant while others remove multiple<br />

contaminants from your gas stream. There are several<br />

factors you need to consider when selecting purifiers for your<br />

application. These include contaminants potentially present in<br />

your gas stream, gas purity levels required, flow and pressure<br />

limitations, space availability, and desired convenience when<br />

replacing spent traps.<br />

Moisture, hydrocarbon, and oxygen traps are the most<br />

commonly used purifiers for GC applications. Moisture traps<br />

are typically packed with molecular sieves. After extensive<br />

heating, these crystalline structures lose their water of<br />

hydration opening a cavity that is readily filled with any<br />

compound that can fit. Water fits perfectly. However, it will<br />

also remove HCl, CO2, SO2, Cl2, or any gas with an effective<br />

diameter smaller than water.<br />

gc accessories | purifiers<br />

Cartridge Style<br />

5334 5335<br />

How Contaminants Affect Your Gas Stream<br />

In-Line Style<br />

Table 1—Gas Purifier Styles<br />

Cartridge Style<br />

In-Line Style<br />

Placement: Stands on Benchtop Freely supported on<br />

gas lines<br />

Repeat Use: Replace Cartridge Refill*<br />

Benefit:<br />

Convenient access, stops<br />

gas flow when changing<br />

cartridges<br />

Occupies wall space<br />

not bench space<br />

*Refills for most materials are available. See specific gas purifiers for refill kit<br />

part numbers.<br />

Follow the path that your carrier gas or detector fuel gases<br />

take to get to the GC. They start at either a gas tank or a gas<br />

generator, and travel through long lengths of tubing, pressure<br />

gauges, various fittings, and valves. Each is a potential culprit<br />

for introducing contaminants into your gas stream, which<br />

ultimately degrades chromatography results and shortens<br />

column life.<br />

Hydrocarbon traps are packed with an activated charcoal that<br />

adsorbs any organic compound larger than methane. Size<br />

and molecular weight of the organic contaminants will greatly<br />

effect the capacity of the trap, and to a smaller degree, trap<br />

efficiency. Activated charcoal has a higher capacity for larger<br />

(>C4) hydrocarbons than for smaller hydrocarbons.<br />

Oxygen traps are packed with a metal catalyst. Oxygen is<br />

the most detrimental contaminant to analytical columns. It<br />

produces irreversible oxidation damage particularly to polar<br />

stationary phases. Refer to Table 2 for a recommendation of<br />

what purifiers to use for various GC applications.<br />

Table 2—Gas Purifier Recommendations<br />

System Detector Gas Stream Recommended Purifier<br />

Packed Column GC<br />

All Carrier Gas Hydrocarbon, Moisture, Oxygen,<br />

and Indicating Oxygen<br />

Capillary Column GC<br />

All Carrier Gas Hydrocarbon, Moisture, Oxygen,<br />

and Indicating Oxygen<br />

ECD Make-Up Moisture and Oxygen<br />

FID Make-Up Hydrocarbon<br />

FID Air for FID Hydrocarbon<br />

FID Hydrogen for FID Hydrocarbon<br />

ELCD ELCD Reaction Gas Hydrocarbon<br />

Typical contaminants, such as moisture, oxygen, and<br />

hydrocarbons wreak havoc with GC columns and detectors.<br />

Capillary and packed columns can degrade when exposed<br />

to moisture or oxygen, particularly at high temperatures.<br />

Detector performance may also be compromised. Since the<br />

detector can actually “see” the contaminants, spikes, baseline<br />

noise, and drift result.<br />

268 www.discoverysciences.com


gas chromatography<br />

Physical Characteristics<br />

You will also need to consider what physical characteristics<br />

your purifier should possess to meet your application<br />

requirements. Do you require 1/8" or 1/4" fittings, or are you<br />

performing bulk gas purification that requires 1/2" fittings?<br />

What are the pressure requirements of your application? This<br />

will determine if you need a purifier with a polycarbonate,<br />

glass, or metal body. Where will you be installing the purifier<br />

and is your installation space limited? This will determine the<br />

dimension and style of purifier you should choose.<br />

Carrier Gas<br />

Figure 1 — How to Set Up Carrier Gas Purifiers<br />

1. High Capacity or Indicating Moisture Trap<br />

2. High Capacity Hydrocarbon Trap<br />

1<br />

Carrier Gas Line<br />

2 3 4<br />

Gas Chromatograph<br />

Chemical<br />

Filter Supplied<br />

with GC<br />

Gas Purifier Installation Order<br />

3. Oxygen Trap<br />

(high capacity)<br />

4. Indicating Oxygen<br />

Trap<br />

4138<br />

Purifier Styles<br />

<strong>Grace</strong> offers two purifier styles—in-line and cartridge. The<br />

in-line style is the traditional style that is most commonly used.<br />

It can be directly installed into your gas lines with no support<br />

depending on its dimension or can be easily mounted on the<br />

wall with mounting clips. In-line purifiers must be removed<br />

from the gas line to be refilled or regenerated. We recommend<br />

installing them with quick-connect connectors and keeping an<br />

extra purifier on hand.<br />

The cartridge style purifier sits on the countertop for easy<br />

access when it is time to replace spent traps. The cartridge<br />

style can be installed in series with shut off valves allowing<br />

you to easily isolate them from your gas lines when it is<br />

time to replace them. Cartridge purifiers allow you to quickly<br />

remove the spent purifier from your gas line and replace it<br />

with a new one.<br />

Purifier Capacity<br />

Purifier capacity indicates the amount of contaminant a<br />

trap is capable of removing before it reaches its point of<br />

saturation. It is dependent on both the adsorbent’s capabilities<br />

and purifier’s volume. You need to consider the amount of<br />

impurities in your gas stream and the volume of gas you<br />

need to purify. If you are purifying a large volume of gas or<br />

a less pure gas, you should select a high capacity trap with<br />

a large volume adsorbent bed that will trap and retain more<br />

contaminants.<br />

Purifier Efficiency<br />

Purifier efficiency is the most important purifier characteristic.<br />

It indicates how effective the adsorbent is at removing the<br />

desired contaminant from your gas stream. If your application<br />

requires high purity levels or the lowest detection limits, select<br />

a purifier that is packed with a highly efficient adsorbent<br />

material that removes contaminants to ppb levels.<br />

The order in which you install purifiers into your gas lines is<br />

very important. Figure 1 demonstrates the correct order for<br />

installing purifiers into your carrier gas line. The moisture trap<br />

should be placed first in line. Both hydrocarbon and oxygen<br />

traps will adsorb water. Installing a moisture trap before these<br />

traps prevents them from becoming prematurely saturated<br />

with moisture. It also allows them to more effectively remove<br />

their specified contaminants from the gas stream. The<br />

hydrocarbon trap should be placed after the moisture trap.<br />

A high-capacity oxygen trap and an indicating oxygen trap<br />

should be placed closest to the GC. We recommend installing<br />

the series of purifiers as close to the GC as possible.<br />

Gas purifiers should be installed in a vertical position to<br />

prevent channeling. Channeling is a phenomenon that occurs<br />

when a purifier is installed in a horizontal position. The<br />

adsorbent bed settles and the gas stream passes over the top<br />

of the bed rather than through the bed. The gas stream does<br />

not sufficiently interact with the adsorbent bed to effectively<br />

remove impurities.<br />

Gas purification systems simplify purifier installation in to your<br />

gas lines. Systems are available as multi-adsorbent single<br />

purifiers or compact panels that contain multiple purifiers.<br />

Purifier Replacement/Regeneration<br />

You need to replace your gas purifiers before they are fully<br />

saturated. You can either change them at a predetermined<br />

time interval or use an indicating trap that changes color<br />

as it becomes saturated. There are potential problems with<br />

scheduled replacements. Undetected leaks or accidental<br />

exposure to air during cylinder changes can prematurely<br />

saturate gas purifiers. Early breakthrough means your column<br />

and detectors are exposed to a constant stream of damaging<br />

contaminants. An indicating trap located downstream from a<br />

high capacity trap is the best way to determine when it’s time<br />

to replace a spent trap. Some purifiers contain both the high<br />

capacity and indicating adsorbent in the same purifier body<br />

while others rely on a separate trap that serves solely as an<br />

indicator. Either way, purifier replacement should coincide with<br />

the first signs of color change in the indicating adsorbent.<br />

gc accessories | purifiers<br />

www.discoverysciences.com<br />

269


gas chromatography<br />

gc accessories | purifiers<br />

Moisture Traps<br />

Remove Moisture From Your Gas System<br />

• Eliminate stationary phase degradation<br />

• Increase column life<br />

• Improve the quality of your chromatography<br />

Remove moisture from gas cylinders, regulators and gas lines<br />

with a <strong>Grace</strong> moisture trap. In addition to H2O, most traps<br />

(except the ALL-Pure and Sodium Sulfate) also remove HCl,<br />

SO2, NO2, H2S, CO2, oil, and small aliphatics. Both indicating<br />

and non-indicating traps are available. Many traps can be<br />

regenerated and are refillable—order refill kits separately.<br />

Alltech ® Cartridge Style Moisture Trap<br />

A) Cartridge Style Moisture Trap<br />

– Simply replace the cartridge when spent<br />

– Gas flow stops while cartridge is changed<br />

– Order baseplate unit separately below<br />

In-Line Style Moisture Traps<br />

B) Alltech ® Standard Moisture Trap<br />

– Suitable for air lines<br />

– Refillable<br />

– SS screen at outlet prevents particulates from entering the<br />

gas stream<br />

C) Alltech ® Traditional Hydro-Purge Moisture Trap<br />

– Sorbsil ® Chameleon ® indicating material<br />

– SS screens at each end prevent particulates from entering<br />

the gas stream<br />

D) Alltech ® Hydro-Purge II Moisture Trap<br />

– 40µm SS frits in endfittings prevent particulates from entering<br />

the gas stream<br />

– Larger capacities than the Traditional Hydro-Purge<br />

In-Line Style Moisture Traps (continued)<br />

E) Alltech ® Glass Moisture Trap<br />

– Best for carrier gas lines<br />

– Glass housing eliminates diffusion<br />

– 40µm SS frits in endfittings prevent particulates from entering<br />

the gas stream<br />

F) ALL-Pure Moisture Trap<br />

– Removes moisture down<br />

to


gas chromatography<br />

Oxygen Traps<br />

Protect Columns From Oxygen Contamination<br />

Prevent oxidation of column stationary phases with <strong>Grace</strong><br />

oxygen traps. Use an oxygen trap to help maintain column<br />

performance and prolong column life. Traps are available in<br />

cartridge and in-line styles. Choose an indicating trap to easily<br />

identify when trap is spent or to use in conjunction with larger<br />

capacity traps. Some traps can be regenerated—see table on<br />

following page.<br />

Alltech ® Cartridge Style Oxygen Traps<br />

A) AT-Indicating Oxy Cartridge<br />

– Features the OXY-MAX adsorbent<br />

– Easy to replace—simply change cartridge<br />

– Gas flow stops while cartridge is charged<br />

– Order baseplate separately below<br />

B) AT-Omni Cartridge<br />

– Features the OXY-MAX adsorbent<br />

– Also removes moisture and hydrocarbons<br />

– Easy to replace—simply change cartridge<br />

– Gas flow stops while cartridge is charged<br />

– Order baseplate separately below<br />

Don’t forget the baseplate for cartridge<br />

style traps. Part No. 81025.<br />

In-Line Style Oxygen Traps<br />

C) Alltech ® Oxy-Trap<br />

– Features OXY-MAX adsorbent<br />

– Compact coil design<br />

D) Alltech ® Large Oxy-Trap<br />

– Same as original Oxy-Trap<br />

except larger capacity<br />

E) Alltech ® Indicating Oxy-Trap<br />

– Features OXY-MAX<br />

adsorbent<br />

– Glass housing eliminates diffusion<br />

F) Alltech ® Indicating Oxy-Purge ®<br />

– Glass housing<br />

eliminates diffusion<br />

– Endfittings contain<br />

40µm SS frits for particulate control<br />

G) Oxy-Purge ® N<br />

– Also removes moisture<br />

– Rugged aluminum<br />

housing<br />

– 40µm SS frits in endfittings prevent particulates from entering<br />

gas stream<br />

H) ALL-Pure Oxygen Trap<br />

– Also removes<br />

moisture<br />

– Capacity of 1030mL<br />

of oxygen<br />

I) Oxi Clear Oxygen Trap<br />

– Removes oxygen, moisture, and<br />

hydrocarbons<br />

J) Alltech ® BIG Oxygen Trap<br />

– Our highest capacity<br />

trap—3000mL<br />

gc accessories | purifiers<br />

K) Alltech ® High-Pressure Oxy-Trap<br />

– Features OXY-MAX<br />

adsorbent<br />

– Handles pressures up<br />

to 1800psig<br />

Cartridge Oxygen Traps<br />

Pressure<br />

Limit Fitting Dimensions (L x o.d.) Indicator Part No.<br />

Regeneration Service<br />

Part No.<br />

Photo Description Capacity Efficiency<br />

Cartridge Style Traps<br />

A AT-Indicating Oxy 104mL


gas chromatography<br />

gc accessories | purifiers<br />

Hydrocarbon, CO2, and Sulfur Traps<br />

Eliminate Detector Noise and Increase<br />

Baseline Stability<br />

• Choose baseplate, cartridge, or in-line styles<br />

• Indicating hydrocarbon trap available<br />

<strong>Grace</strong> hydrocarbon traps adsorb trace amounts of<br />

hydrocarbons and organics from your gas stream. Most<br />

traps are packed with activated charcoal and adsorb organic<br />

compounds larger than methane. Traps are available in a<br />

baseplate style that sits on the benchtop, a cartridge style that<br />

allows for easy replacement of the trap (requires baseplate<br />

unit to be ordered separately), and an in-line style that is<br />

freely supported on gas lines. Traps for CO2, and sulfur are<br />

also available.<br />

Alltech ® Cartridge Style Traps<br />

A) Organic Cartridge Trap<br />

– Economical<br />

B) AT-Omni Cartridge Trap<br />

– Removes hydrocarbons, moisture,<br />

and oxygen<br />

– Indicating for oxygen<br />

A<br />

Don’t forget the baseplate for cartridge<br />

style traps. Part No. 81025.<br />

B<br />

In-Line Style Traps<br />

C) Alltech ® Activated Charcoal Trap<br />

– Two sizes available<br />

D) Hydrocarbon Trap<br />

– Economical<br />

– 250psig pressure rating<br />

E) Alltech ® Hi-EFF Organic Trap<br />

– Removes hydrocarbons and moisture<br />

– Indicating for moisture<br />

F) Alltech ® BIG Hydrocarbon Trap<br />

– Large 750cc size<br />

– Helium purged prior to shipment<br />

G) ALL-Pure Hydrocarbon Trap<br />

– Removes hydrocarbons to


gas chromatography<br />

Alltech ® Gas Purification<br />

Cartridge Systems<br />

• Replace spent purifiers without shutting down your system<br />

Alltech ® gas purification cartridges allow replacement of spent<br />

cartridges in seconds without shutting down your GC system.<br />

Simply pull the spent cartridge off the baseplate and push a<br />

new one into place.<br />

A knurled locking<br />

ring keeps the<br />

cartridge locked<br />

in place. Four<br />

different purification<br />

cartridges are<br />

available. Multiple<br />

cartridges and<br />

baseplates can be<br />

plumbed together<br />

to customize a gas<br />

Knurled<br />

locking ring<br />

Convenient cartridge baseplate<br />

automatically stops gas flow<br />

when changing cartridges<br />

purification system for your application. Order each cartridge<br />

separately below.<br />

Moisture Trap Cartridge—Filled with indicating Sorbsil ®<br />

Chameleon ® indicating material and molecular sieve pellets to<br />

maximize moisture removal and to indicate when the cartridge<br />

requires refilling or replacement. A refill kit is available below.<br />

Organic Trap Cartridge—Removes non-methane<br />

hydrocarbons from your gas stream. A refill kit is available<br />

below.<br />

AT-Omni Cartridge—A multi-purpose cartridge filled with<br />

OXY-MAX and Hi-EFF Charcoal to effectively remove<br />

oxygen, moisture and hydrocarbons. AT-Omni cartridges<br />

are disposable.<br />

AT-Indicating Oxy Cartridge—Filled with OXY-MAX and<br />

indicating oxygen adsorbent to efficiently remove oxygen and<br />

small amounts of moisture. The indicating material shows a<br />

color change when the cartridge is saturated. AT-Indicating<br />

Oxy cartridges are disposable.<br />

ALL-Pure Gas Purifiers<br />

• One purifier removes multiple contaminants<br />

• Reduce impurities to low ppb levels<br />

ALL-Pure Gas Purifiers feature a unique proprietary<br />

broad spectrum adsorbent material that removes multiple<br />

contaminants with a single purifier. Replace three separate<br />

purifiers for oxygen, moisture, and hydrocarbons with a single<br />

ALL-Pure purifier. Purifiers are gas specific or choose<br />

purifiers specific for moisture, hydrocarbons, or oxygen.<br />

ALL-Pure Specifications<br />

Dimensions: 400cc, 21" L x 1.5" o.d. (50.8cm x 3.8cm)<br />

Max Flow: 500mL/min<br />

Max. Pressure: 1000psig<br />

Max. Temp: 80°C<br />

Mounting: Purifier must be mounted in vertical position<br />

Purifier Selectivity and Purity Specifications*<br />

Purifier CO CO2 O2 H2O<br />

Sulfur<br />

Compounds<br />

Non-Methane<br />

Hydrocarbons<br />

Helium Purifier:


gas chromatography<br />

SGT Super Clean Filters<br />

Improve Baselines, Minimize Interferences,<br />

and Reduce MS Maintenance<br />

• Remove impurities to deliver 99.9999% pure gas<br />

• Exchange filters in seconds, without introducing air<br />

into the system<br />

• Diffusion-proof with glass and metal construction<br />

• Pressure resistant up to 150psig (11 bar)<br />

These SGT Super Clean filters can be used on all of your<br />

GC gas lines to deliver 99.9999% pure gas. Filters are<br />

available for oxygen, moisture and hydrocarbons. The<br />

Combi filter removes both moisture and hydrocarbons. The<br />

Triple filter removes moisture, oxygen, and hydrocarbons and<br />

is available purged with Argon for standard applications or<br />

purged with Helium for MS applications.<br />

gc accessories | purifiers<br />

Filters feature a quick change baseplate/cartridge design.<br />

Cartridges can be exchanged within seconds, during analysis,<br />

and without tools. 1-, 2-, 3-, or 4-position baseplates are<br />

available and will accept any of the GC filter cartridges.<br />

Baseplates must be ordered separately (except for systems).<br />

Filter cartridge bundles include the most popular filters in<br />

one package. Various filter systems are available and include<br />

the appropriate baseplate.<br />

SGT Super Clean Filter Specifications<br />

Maximum Flow:<br />

7.0L/min<br />

Efficiency:<br />


gas chromatography<br />

Purifier Accessories<br />

Universal Mounting Panel<br />

• Mount up to five purifiers for easy monitoring<br />

and replacement<br />

• Pre-drilled for easy mounting<br />

• Fits most manufacturers’ purifiers<br />

This lightweight aluminum mounting panel will hold up to five<br />

purifiers. Pre-drilled holes are spaced at 3/4" centers in five<br />

vertical rows to allow for maximum versatility. Mounting clips<br />

to accommodate purifiers from 7/8" to 2-1/2" o.d. (2.2cm<br />

to 6.4cm) are sold separately below. Panel measures<br />

17" W x 24" H (43.2cm W x 61cm H).<br />

In-Line Particulate Filter<br />

• Economically remove particulates from gas streams<br />

This brass in-line particulate filter is a convenient, inexpensive<br />

way to remove particulates from critical gas streams. Each<br />

unit includes one 10 micron filter cartridge. The maximum<br />

pressure rating is 500psig.<br />

4858<br />

In-Line Particulate Filters<br />

Description<br />

Part No.<br />

1/4" In-line Brass Filter 8052<br />

1/8" In-line Brass Filter 8054<br />

4854<br />

related products<br />

Need a leak detector?<br />

Ensure leak-free installation of your gas<br />

purifiers. See page 267 for gas leak<br />

detectors.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

gc accessories | purifiers<br />

Universal Mounting Panel<br />

Description Qty. Part No.<br />

Universal Mounting Panel ea 7220<br />

Universal Mounting Clips<br />

Fits 7/8" to 1" o.d. Traps 2/pk 7221<br />

Fits 1-1/8" to 1-3/8" o.d. Traps 2/pk 7223<br />

Fits 1-3/8" to 1-5/8" o.d. Traps 2/pk 7225<br />

Fits 1-5/8" to 1-7/8" o.d. Traps 2/pk 7227<br />

Fits 2" to 2-1/2" o.d. Traps 2/pk 7229<br />

www.discoverysciences.com<br />

275


gas chromatography<br />

Gas Sampling Bags<br />

Selection Guides<br />

FEP Gas Sampling Bags, 5mil<br />

Tensile Strength*<br />

Fittings Available (by ASTM D-882)<br />

Barbed on/off<br />

Septum Port<br />

Dual<br />

1/4" SS Fitting<br />

2N1 Combination<br />

2500–3000psig<br />

(Note: This is NOT<br />

a burst pressure<br />

rating for the bag.)<br />

Permeability<br />

Gas<br />

CO2<br />

Hydrogen<br />

Nitrogen<br />

Oxygen<br />

Acetic Acid<br />

Vapor<br />

Acetone<br />

Benzene<br />

CCl4<br />

Ethanol<br />

Hexane<br />

Water<br />

Permeability**<br />

1670<br />

2200<br />

320<br />

750<br />

0.41<br />

Permeability***<br />

0.95<br />

0.64<br />

0.31<br />

0.69<br />

0.56<br />

0.45<br />

Temp. Limits<br />

min.–max. Sample Compatibility Advantage<br />

-240–260°C<br />

Inert and solvent resistant<br />

to virtually all chemicals<br />

except molten alkali metals,<br />

gaseous fluorine, complex<br />

halogenated compounds<br />

at elevated pressure and<br />

temperature<br />

Low permeability to liquids,<br />

gases, moisture and organic<br />

vapors; suitable for<br />

cryogenic use<br />

gc accessories | gas sampling<br />

Tedlar ® PVF, 2mil<br />

Fittings Available<br />

Barbed on/off<br />

Septum Port<br />

Dual<br />

1/4" SS Fitting<br />

2N1 Combination<br />

Tensile Strength*<br />

(by ASTM D-882) Permeability<br />

Gas<br />

17,000–18,000psig<br />

(Note: This is NOT<br />

a burst pressure<br />

rating for the bag.)<br />

CO2<br />

Hydrogen<br />

Nitrogen<br />

Oxygen<br />

Vapor<br />

Acetic Acid<br />

Acetone<br />

Benzene<br />

CCl4<br />

Ethyl Acetate<br />

Ethanol<br />

Hexane<br />

Water<br />

Permeability**<br />

11.1<br />

150<br />

0.25<br />

3.2<br />

Permeability***<br />

45<br />

10,000<br />

90<br />

50<br />

1.000<br />

35<br />

55<br />

180<br />

Temp. Limits<br />

min.–max. Sample Compatibility Advantage<br />

-234–300°C<br />

Cali-5-Bond 5.5mil (polyethylene, polyamide, aluminum foil, polyvinyl, chloride polyester)<br />

Fittings Available<br />

2N1 Combination<br />

Barbed on/off<br />

Septum Port<br />

Tensile Strength*<br />

(by ASTM D-882)<br />

Recommended for analysis<br />

of non-corrosive gases,<br />

TCLP gases, CO, H2S,<br />

radon, and mercaptans;<br />

“Grab” sampling; preparation<br />

of calibration gas standards;<br />

gas blending; stack<br />

sampling; emission testing<br />

Temp. Limit<br />

max. Sample Compatibility Advantage<br />

Permeability<br />

— — 54°C Designed specifically for<br />

collecting air samples;<br />

suitable for the storage<br />

and transportation of<br />

gas samples<br />

*Tensile strength is the maximum force required to rupture a one-inch wide specimen. **cc/(100in 2 )(24hrs)(atm/mil). ***gms/(100in 2 )(24hrs/mil).<br />

Lowest permeability of all<br />

types of bags; economical<br />

alternative to PTFE; easily<br />

cleaned and reused<br />

Opaque bag protects sample<br />

from UV degradation; bags<br />

may be purged with nitrogen<br />

or pure air and reused<br />

Available Fittings<br />

<strong>Grace</strong> offers a large variety of gas sampling bag fittings. Consider the following when selecting a fitting:<br />

1. How will you collect the sample? What type of connection is available to connect to the bag?<br />

2. How will you need to access the sample once it is collected in the bag?<br />

3. Is your sample compatible with the fitting material?<br />

Nickel-plated Barbed<br />

On-Off Valve<br />

6644 6642 6738 6645 6643<br />

PTFE Septum Port Dual On-Off/Septum 1/4" SS Swagelok ® 2N1 Combination<br />

On-Off/Septum<br />

more info<br />

Need a syringe?<br />

See pages 336–347 for our complete selection of syringes.<br />

276 www.discoverysciences.com


gas chromatography<br />

Gas Sampling Bags<br />

Tedlar ® Gas Sampling Bags<br />

• High tensile strength resists puncture<br />

• Low permeability minimizes sample loss<br />

Tedlar ® bags are manufactured from sturdy 2mil PVF film that is inert to<br />

a wide range of gases. Low permeability ensures the integrity of your<br />

sample and makes Tedlar ® bags the ideal choice for off site analysis.<br />

Tedlar ® Gas Sampling Bags<br />

Barbed On-Off Valve<br />

Part No.<br />

Septum Port<br />

Part No.<br />

Dual On-Off/Septum Port<br />

Part No.<br />

1/4" SS Swagelok ®<br />

Part No.<br />

Nominal Size<br />

Volume<br />

6" x 6" 0.6L 41021 41023 41025 41027<br />

6" x 10" 1.2L 41029 41031 41033 41035<br />

6" x 12" 1.5L 41037 41039 41041 41043<br />

9" x 9" 2L 41045 41047 41049 41051<br />

12" x 12" 5L 41053 41055 41057 41059<br />

12" x 19" 10L 41063 41065 41067 41069<br />

18" x 18" 16L 41071 41073 41075 41077<br />

24" X 24" 40L 41079 41081 41083 41085<br />

24" x 30" 56L 41087 41089 41091 41093<br />

24" x 36" 73L 41095 41097 41099 41032<br />

30" x 30" 80L 41034 41036 41038 41042<br />

FEP Gas Sampling Bags<br />

• 5mil thickness for durability<br />

• Manufactured and packaged under GLP conditions<br />

FEP bags have a 5mil film thickness making them suitable for harsh<br />

sampling conditions. Bags are chemically resistant to the most severe<br />

corrosives. Choose from four different port types.<br />

FEP Gas Sampling Bags<br />

Barbed On-Off Valve<br />

Part No.<br />

Septum Port<br />

Part No.<br />

Dual On-Off/Septum<br />

Port Part No.<br />

1/4" SS Swagelok ®<br />

Part No.<br />

Nominal Size<br />

Volume<br />

6" x 6" 0.6L 41044 41046 41048 41052<br />

6" x 10" 1.2L 41054 41056 41058 41064<br />

6" x 12" 1.5L 41066 41068 41072 41074<br />

9" x 9" 2L 41076 41078 41082 41084<br />

12" x 12" 5L 41086 41088 41092 41094<br />

12" x 19" 10L 41106 41108 41109 41125<br />

18" x 18" 16L 41127 41129 41131 41133<br />

24" x 24" 40L 41135 41137 41139 41149<br />

24" x 30" 56L 41151 41153 41155 41157<br />

24" x 36" 73L 41126 41128 41132 41134<br />

30" x 30" 80L 41136 41138 41152 41154<br />

6647<br />

6646<br />

gc accessories | gas sampling<br />

Replacement Parts<br />

Replacement Parts for Tedlar ® and FEP Bags<br />

Description<br />

Part No.<br />

Replacement Septa for Septa Port, 10/pk 41158<br />

1/4" PTFE No Hole Ferrules for 1/4" SS Fitting, 10/pk RF-400/0-T<br />

www.discoverysciences.com<br />

277


gas chromatography<br />

Gas Sampling Bags<br />

Combo Valve Gas Sampling Bags<br />

• On/off valve and septum in one fitting<br />

• Save with convenient multi-packs<br />

Cali-5-Bond 5-Layer Gas Sampling Bags<br />

• Non-permeable<br />

• Opaque to UV and visible light<br />

• Inert, flexible, tough, and reusable<br />

best<br />

seller<br />

6648 1651<br />

gc accessories | gas sampling<br />

Combo valve gas sampling bags give the convenience and<br />

ease of a barbed on/off valve and a septum port combined<br />

into one fitting. The valve fitting features a 3/16" stem, which<br />

is suitable for use with most 1/4" tubing, and a sampling port.<br />

Bags are available in Tedlar ® and FEP as well as convenient<br />

multi-packs.<br />

Combo Valve Gas Sampling Bags<br />

Size Volume Port Description Part No.<br />

Tedlar ® Gas Sampling Bags<br />

7 x 7" 1L 2N1 41001<br />

9 x 9" 2L 2N1 41003<br />

12 x 12" 5L 2N1 41007<br />

12 x 19" 10L 2N1 41011<br />

18 x 24" 25L 2N1 41017<br />

FEP Gas Sampling Bags<br />

6 x 6" 0.6L 2N1 41002<br />

6 x 10" 1.2L 2N1 41004<br />

6 x 12" 1.5L 2N1 41006<br />

9 x 9" 2L 2N1 41008<br />

Tedlar ® Combo Valve Multi-Packs<br />

Size Volume Port Description Qty. Part No.<br />

7 x 7" 1L 2N1 10 48001<br />

9 x 9" 2L 2N1 10 48003<br />

12 x 12" 5L 2N1 10 48007<br />

12 x 19" 10L 2N1 10 48011<br />

18 x 24" 25L 2N1 5 48017<br />

Cali-5-bond gas sampling bags are constructed from<br />

inert 5.5mil thick material made from five layers of film.<br />

The layers are comprised of an inner layer of high-density<br />

polyethylene, followed by polyamide, an aluminum foil barrier,<br />

a polyvinylidene chloride layer and an outer layer of polyester.<br />

These bags are specifically designed for air sampling and are<br />

suitable for the storage and transportation of gas samples.<br />

Cali-5-Bond bags are available in both pillow and snout<br />

shapes. The snout provides additional entry into the bag for<br />

flushing and sample collection.<br />

Bags are equipped with a barbed on-off valve and silicone<br />

septum for easy sampling and can be purged with nitrogen<br />

or pure air gas and reused.<br />

5-Layer Gas Sampling Bags<br />

Nominal Size Volume Port Description Part No.<br />

Snout-Shaped Gas Sampling Bags<br />

8 x 15" 2L Barbed Valve 1" Septa 4150<br />

8 x 27" 5L Barbed Valve 1" Septa 4152<br />

16 x 16" 10L Barbed Valve 1" Septa 4186<br />

22 x 24" 22L Barbed Valve 1" Septa 4154<br />

Pillow-Shaped Gas Sampling Bags<br />

8 x 8" 1L Barbed Valve 1" Septa 4188<br />

8 x 11" 2L Barbed Valve 1" Septa 4190<br />

16 x 19" 15L Barbed Valve 1" Septa 4192<br />

31 x 55" 170L Barbed Valve 1" Septa 4198<br />

278 www.discoverysciences.com


gas chromatography<br />

Gas Sampling Accessories<br />

Gas Sampling Bulb with Septum Ports<br />

• PTFE stopcocks for increased compatibility<br />

Gas Sampling Bulbs<br />

Description<br />

Part No.<br />

125mL, PTFE Stopcock 7012<br />

250mL, PTFE Stopcock 7013<br />

500mL, PTFE Stopcock 7011<br />

1000mL, PTFE Stopcock 7066<br />

Replacement Septa, 12/pk 7000<br />

Gas Sampling Bulb with Twist-Lock Stopcocks<br />

• Unique twist-lock stopcocks<br />

• PTFE outlet tube connectors<br />

Gas Sampling Bulb with Injection Port and<br />

Valve Stopcocks<br />

• Stored sample contacts only glass and PTFE<br />

• Suitable for vacuum or pressure<br />

• Semi-needle valve control<br />

4663<br />

4664<br />

best<br />

seller<br />

Gas Sampling Bulbs<br />

Description<br />

Part No.<br />

125mL, PTFE Stopcock 6950<br />

250mL, PTFE Stopcock 6952<br />

500mL, PTFE Stopcock 6954<br />

Replacement Septa, 10/pk 6900<br />

Vacuum Sampler<br />

• No external pump required<br />

• Reusable<br />

These evacuated 1L vacuum samplers are fitted<br />

with a unique septum port and needle guide<br />

through which the container is filled and samples<br />

removed. A 4" long needle is supplied with each<br />

vacuum sampler (2 needles with the package of<br />

12 samplers).<br />

Vacuum Sampler<br />

Description<br />

Part No.<br />

1L (1 needle), ea 8020<br />

1L (2 needles), 12/pk 8022<br />

Replacement Septa, 12/pk 8015<br />

Gas and Vapor Sampler<br />

• Sample bags are removable and resealable<br />

Collect samples in resealable 200cc multilayer bags.<br />

Simply evacuate the canister using the supplied<br />

aspirator bulb. The bags can be removed for storage<br />

or shipment, freeing the canister for further sampling.<br />

Ten bags are included with each kit.<br />

Gas and Vapor Sampler<br />

Description<br />

Part No.<br />

Gas and Vapor Sampler Kit 4182<br />

Replacement Bags, 10/pk 4184<br />

related products<br />

Looking for syringes?<br />

See pages 336–347.<br />

6310<br />

4668<br />

gc accessories | gas sampling<br />

4665<br />

Gas Sampling Bulbs<br />

Description<br />

Part No.<br />

125mL 6940<br />

250mL 6942<br />

500mL 6944<br />

13-425 Open-Hole Caps, 100/pk 73090<br />

TFE/Silicone Liners, 100/pk 98123<br />

www.discoverysciences.com<br />

279


gas chromatography<br />

GC Ferrule Selection<br />

PTFE Ferrules<br />

PTFE ferrules are completely inert and an economical choice.<br />

They have an upper temperature limit of 250°C. PTFE ferrules<br />

conform well to the shape of the column upon compression<br />

and can be reused if handled carefully.<br />

Graphite Ferrules<br />

These 99.95% pure graphite ferrules can be used at<br />

temperatures up to 450°C without producing bleed or<br />

decomposition products. The one-piece design requires no<br />

back ferrules. Graphite ferrules are very soft and conform well<br />

to the column on compression. These ferrules can be reused<br />

as long as care is taken not to overtighten them.<br />

Vespel ® Ferrules<br />

Vespel ® ferrules do not cold flow, are easily reusable, and<br />

withstand temperature up to 350°C. At high temperatures,<br />

Vespel ® may adhere to glass or metal.<br />

Vespel ® /Graphite Ferrules<br />

Composites of Vespel ® and graphite combine the advantages<br />

of the two materials. They are less likely to adhere to the<br />

column than Vespel ® but are more durable than graphite.<br />

Ferrules are easy to reuse and stable at temperatures to<br />

400°C.<br />

Two types of composites are available. The VG1 composite<br />

is 85% Vespel ® /15% graphite and suitable for all-purpose<br />

applications. The VG2 type is 60% Vespel ® /40% graphite and<br />

exhibits added lubricity.<br />

gc accessories | fittings<br />

Ferrule Properties<br />

Material Temp. Limit Reusability Resealing Properties Suitability for Glass Temp. Prog.<br />

PTFE 250°C Good Excellent Excellent No<br />

Graphite 450°C Good Excellent Excellent Yes<br />

Vespel ® 350°C+ Excellent Good Good Yes<br />

VG1 400°C Excellent Good Excellent Yes<br />

VG2 400°C Excellent Good Excellent Yes<br />

ptfe and Graphite Ferrules<br />

Description Fitting Size Tubing Size Qty.<br />

Straight Ferrules<br />

Used when<br />

the tubing o.d.<br />

matches the<br />

nominal size<br />

of the fitting<br />

being used.<br />

Reducing Ferrules<br />

Used when<br />

the tubing o.d.<br />

is smaller than<br />

the nominal size<br />

of the fittings.<br />

PTFE<br />

Part No.<br />

What ferrule type do you need?<br />

Ferrule Type Use for:<br />

0.4mm Hole: Capillaries with i.d. of 0.10-0.25mm<br />

0.5mm Hole: Capillaries with i.d. of 0.28-0.35mm<br />

0.8mm Hole: Capillaries with i.d. of 0.45-0.53mm<br />

NO-HOLE: As plugs, or drill for special needs<br />

2-HOLE: Connecting two pieces of capillary tubing<br />

or columns to the same endfitting<br />

Graphite<br />

Part No.<br />

1" 1" 2 — 14361<br />

7/8" 7/8" 2 — 14360<br />

3/4" 3/4" 2 — 14358<br />

5/8" 5/8" 2 — 14357<br />

1/2" 1/2" 10 — SF-800-G<br />

3/8" 3/8" 10 SF-600-T SF-600-G<br />

1/4" 1/4" 10 SF-400-T SF-400-G<br />

3/16" 3/16" 10 SF-300-T SF-300-G<br />

1/8" 1/8" 10 SF-200-T SF-200-G<br />

1/16" 1/16" 10 SF-100-T SF-100-G<br />

1/4" 1/16" 10 RF-400/100-T RF-400/100-G<br />

1/4" 0.8mm 10 — RF-400/0.8-G<br />

1/4" 1/8" 10 RF-400/200-T RF-400/200-G<br />

1/4" 3/16" 10 RF-400/300-T 14327<br />

1/4" 4mm 10 — 14384<br />

1/4" 6mm 10 RF-400/6MM-T RF-400/6MM-G<br />

1/8" 1/16" 10 RF-200/100-T RF-200/100-G<br />

1/8" 1.2mm 10 — 14326<br />

1/8" 1.0mm 10 — 14311<br />

1/8" 0.8mm 10 — RF-200/0.8-G<br />

1/8" 0.5mm 10 — RF-200/0.5-G<br />

1/8" 0.4mm 10 — RF-200/0.4-G<br />

1/8" 1.2mm 10 — 14305<br />

1/16" 1.0mm 10 — RF-100/1.0-G<br />

1/16" 0.8mm 10 — RF-100/0.8-G<br />

1/16" 0.5mm 10 — RF-100/0.5-G<br />

1/16" 0.4mm 10 — RF-100/0.4-G<br />

1/16" 0.3mm 10 — 14308<br />

280 www.discoverysciences.com


gas chromatography<br />

GC Ferrules (continued)<br />

PTFE and Graphite Ferrules (continued)<br />

Description Fitting Size Tubing Size Qty.<br />

HP/Agilent Short Ferrules<br />

Two-Hole Ferrules<br />

No-Hole Ferrules<br />

Graphite Ferrules for HP/Agilent Nuts<br />

Vespel ® and Vespel ® /Graphite Ferrules<br />

Description Fitting Size Tubing Size Qty.<br />

Straight Ferrules<br />

Reducing Ferrules<br />

No-Hole Ferrules<br />

Two-Hole Ferrules<br />

Vespel ®<br />

Part No.<br />

PTFE<br />

Part No.<br />

VG1<br />

Part No.<br />

Graphite<br />

Part No.<br />

1/16" 1.2mm 10 — 14370<br />

1/16" 1.0mm 10 — 14325<br />

1/16" 0.8mm 10 — 14324<br />

1/16" 0.5mm 10 — 14323<br />

1/16" 0.4mm 10 — 14322<br />

1/16" 0.3mm 10 — 14321<br />

1/8" 0.8mm 10 — 14334<br />

1/8" 0.5mm 10 — 14307<br />

1/16" 0.5mm 10 — 14330<br />

3/8" — 10 — 14332<br />

1/4" — 10 RF-400/0-T 14328<br />

1/8" — 10 RF-200/0-T 14314<br />

1/16" — 10 RF-100/0-T 14310<br />

0.5mm — — 10 — 1547901<br />

1.0mm Hole — — 10 — 1548001<br />

VG2<br />

Part No.<br />

1/4" 1/4" 10 SF-400-V SF-400-VG1 SF-400-VG2<br />

1/4" 1/4" 10 15449* 15449* 15451*<br />

1/8" 1/8" 10 SF-200-V SF-200-VG1 SF-200-VG2<br />

1/8" 1/8" 10 — 15450* 15452*<br />

1/16" 1/16" 10 SF-100-V SF-100-VG1 SF-100-VG2<br />

1/4" 6mm 10 RF-400/6MM-V 400/6MM-VG1 400/6MM-VG2<br />

1/4" 3/16" 10 RF-400/300-V 400/300-VG1 400/300-VG2<br />

1/4" 1/8" 10 RF-400/200-V 400/200-VG1 400/200-VG2<br />

1/4" 1/16" 10 RF-400/100-V 400/100-VG1 400/100-VG2<br />

1/4" 0.8mm 10 — 400/0.8-VG1 400/0.8-VG2<br />

1/8" 1/16" 10 RF-200/100-V 200/100-VG1 200/100-VG2<br />

1/8" 0.8mm 10 — 200/0.8-VG1 200/0.8-VG2<br />

1/8" 0.5mm 10 — 200/0.5-VG1 200/0.5-VG2<br />

1/8" 0.4mm 10 — 200/0.4-VG1 200/0.4-VG2<br />

1/16" 1.0mm 10 RF-100/1.0-V 100/1.0-VG1 100/1.0-VG2<br />

1/16" 0.9mm 10 RF-100/0.9-V 100/0.9-VG1 100/0.9-VG2<br />

1/16" 0.8mm 10 RF-100/0.8-V 100/0.8-VG1 100/0.8-VG2<br />

1/16" 0.5mm 10 RF-100/0.5-V 100/0.5-VG1 100/0.5-VG2<br />

1/16" 0.4mm 10 RF-100/0.4-V 100/0.4-VG1 100/0.4-VG2<br />

1/16" 0.3mm 10 — 100/0.3-VG1 —<br />

1/4" — 10 RF-400/0-V 400/0-VG1 400/0-VG2<br />

1/8" — 10 RF-200/0-V 200/0-VG1 200/0-VG2<br />

1/16" — 10 RF-100/0-V 100/0-VG1 100/0-VG2<br />

1/16" 0.5mm 10 — 15486 15488<br />

1/16" 0.4mm 10 — 15481 15487<br />

gc accessories | fittings<br />

*Equivalent to Parker one-piece metal ferrule.<br />

www.discoverysciences.com<br />

281


gas chromatography<br />

Fittings Selection Guide<br />

To determine the size of a nut or female pipe thread, compare it to the silhouettes below. To determine the size of a ferrule,<br />

measure its inside diameter. Please note that tubing fitting sizes are based on the outside diameter of the tube, while pipe thread<br />

fitting sizes are based on the inside dimension of the pipe. Pipe and tubing fittings are not interchangeable.<br />

Tubing Nut Sizes*<br />

1/16" 1/8" 3/16" 1/4" 3/8" 1/2"<br />

0127<br />

Female Pipe Thread Connectors*<br />

Tubing<br />

gc accessories | fittings<br />

Tubing<br />

*Silhouettes shown at actual size.<br />

Parker Fittings<br />

1/8" FPT<br />

1/8" (6-2-GBG) 1/4" FPT 3/8" FPT 1/2" FPT<br />

Parker fittings are available in two forms: the CPI one-piece ferrule and the A-Lok two-piece ferrule. Most parts are available in<br />

brass or stainless steel and should be matched to the tubing, particularly in thermal applications.<br />

5767<br />

Parker Fittings<br />

Description Dimensions Qty.<br />

Nuts<br />

Ferrules<br />

CPI<br />

Tees<br />

A-LOK<br />

A-Lok<br />

Brass<br />

Part No.<br />

CPI<br />

Brass<br />

Part No.<br />

Qty.<br />

A-Lok<br />

Stainless Steel<br />

Part No.<br />

CPI<br />

Stainless Steel<br />

Part No.<br />

1/16" 10/pk 11600 14057 10/pk 11700 141575<br />

1/8" 10/pk 11601 14058 10/pk 11701 14158<br />

3/16" 10/pk 11602 60000 10/pk 11702 61000<br />

1/4" 10/pk 11603 14059 10/pk 11703 14159<br />

3/8" 10/pk 11604 60002 10/pk 11704 610025<br />

1/2" 10/pk 11605 600045 5/pk 11705 610045<br />

1/16" 10/pk 11606 14060 10/pk 11706 141605<br />

1/8" 10/pk 11607 14061 10/pk 11707 14161<br />

3/16" 10/pk 11608 60006 10/pk 11708 61006<br />

1/4" 10/pk 11609 14062 10/pk 11709 14162<br />

3/8" 10/pk 11610 60008 10/pk 11710 610085<br />

1/2" 5/pk 11611 600105 5/pk 11711 610105<br />

1/16" ea 11612 14075 ea 11712 14175<br />

1/8" ea 11613 14053 ea 11713 14176<br />

3/16" ea 11614 60012 ea 11714 61012<br />

1/4" ea 11615 14077 ea 11715 14177<br />

3/8" ea 11616 60014 ea 11716 61014<br />

1/2" ea 11617 60016 ea 11717 61016<br />

282 www.discoverysciences.com


gas chromatography<br />

Parker Fittings (continued)<br />

Parker Fittings (continued)<br />

Description Dimensions Qty.<br />

Unions<br />

Reducing Unions<br />

Capillary Union<br />

A-Lok<br />

Brass<br />

Part No.<br />

CPI<br />

Brass<br />

Part No.<br />

Qty.<br />

A-Lok<br />

Stainless Steel<br />

Part No.<br />

CPI<br />

Stainless Steel<br />

Part No.<br />

1/16" ea 11618 14063 ea 11718 14163<br />

1/8" ea 11619 14065 ea 11719 14165<br />

3/16" ea 11620 60018 ea 11720 61018<br />

1/4" ea 11621 14068 ea 11721 14168<br />

3/8" ea 11622 60020 ea 11722 61020<br />

1/2" ea 11623 60022 ea 11723 61022<br />

1/8" to 1/16" ea 11624 14064 ea 11724 14164<br />

3/16" to 1/8" ea 11625 60024 ea 11725 61024<br />

1/4" to 1/16" ea 11626 60026 ea 11726 14166<br />

1/4" to 1/8" ea 11627 60028 ea 11727 61028<br />

1/4" to 3/16" ea 11628 14067 ea 11728 14167<br />

3/8" to 1/16" ea — — ea 11729 14174<br />

3/8" to 1/4" ea 11630 60030 ea 11730 61030<br />

1/16" ea — — ea — 28812<br />

Female Pipe Thread Connectors (Tube to FPT)<br />

1/8" to 1/8" FPT ea 11800 60048 ea 11750 61048<br />

1/8" to 1/4" FPT ea 11801 14071 ea 11751 61084<br />

1/4" to 1/8" FPT ea 11802 60050 ea 11752 61050<br />

1/4" to 1/4" FPT ea 11803 14072 ea 11753 61086<br />

3/16" to 1/8" FPT ea 11804 60052 ea 11754 61052<br />

3/8" to 1/8" 6-2-GBZ ea 11805 60054 ea 11755 61054<br />

3/8" to 1/4" FPT ea 11806 60056 ea 11756 61056<br />

Male Pipe Thread Connectors (Tube to MPT)<br />

1/16" to 1/16" MPT ea 11632 60034 ea 11732 61034<br />

1/16" to 1/8" MPT ea 11633 60036 ea 11733 61036<br />

1/8" to 1/8" MPT ea 11634 60038 ea 11734 61038<br />

1/8" to 1/4" MPT ea 11635 60039 ea 11735 61039<br />

3/16" to 1/8" MPT ea 11636 60040 ea 11736 61040<br />

1/4" to 1/8" MPT ea 11637 60042 ea 11737 61042<br />

3/8" to 1/8" MPT ea 11638 60044 ea 11738 61044<br />

1/4" to 1/4" MPT ea 11639 14069 ea 11739 61082<br />

3/8" to 1/4" MPT ea 11640 60046 ea 11740 61046<br />

Tube End Connectors (Reducers)<br />

1/16" to 1/8" tube ea 11807 60058 ea 11757 61058<br />

1/16" to 1/4" tube ea — — ea 11758 61059<br />

1/8" to 1/4" tube ea 11809 60060 ea 11759 61060<br />

1/8" to 3/16" tube ea 11810 60062 ea 11770 61062<br />

3/16" to 1/4" tube ea 11811 4052 ea 11771 61064<br />

1/4" to 1/8" tube ea 11812 14073 ea 11772 14169<br />

1/4" to 3/8" tube ea 11813 60066 ea 11773 61066<br />

3/8" to 1/4" tube ea 11814 60068 ea 11774 61068<br />

Caps<br />

1/16" ea 11815 14047 ea 11835 14151<br />

1/8" ea 11816 14051 ea 11836 14152<br />

3/16" ea 11817 60070 ea 11837 61070<br />

1/4" ea 11818 14052 ea 11838 14153<br />

3/8" ea 11819 60072 ea 11839 61072<br />

1/2" ea 11820 60074 ea 11840 61074<br />

Plugs<br />

1/16" ea 11821 14054 ea 11841 14154<br />

1/8" ea 11822 14055 ea 11842 14155<br />

3/16" ea 11823 60076 ea 11843 61076<br />

1/4" ea 11824 14066 ea 11844 14156<br />

3/8" ea 11825 60078 ea 11845 61078<br />

1/2" ea 11826 60080 ea 11846 61080<br />

gc accessories | fittings<br />

www.discoverysciences.com<br />

283


gas chromatography<br />

Swagelok ® Tube Fittings<br />

Swagelok ® tube fittings provide a leak-proof, torque-free<br />

seal at all tubing connections and eliminate costly, hazardous<br />

leaks in instrumentation and process tubing.<br />

tech tip<br />

CAUTION: Do not mix or interchange parts of tube fittings made<br />

by other manufacturers with Swagelok ® tube fitting parts.<br />

All the action in the fitting moves along the tube axially instead<br />

of with a rotary motion. Since no torque is transmitted from<br />

the fitting to the tubing, there is no initial strain which might<br />

weaken the tubing.<br />

Swagelok ® Fittings<br />

Description Dimensions Qty.<br />

Nuts<br />

Brass<br />

Part No.<br />

Qty.<br />

Stainless Steel<br />

Part No.<br />

1/16" 10 55002 10 55199<br />

1/8" 10 55003 10 55193<br />

1/4" 10 55005 10 55195<br />

Male Nut<br />

1/16" ea 55084 ea 55184<br />

gc accessories | fittings<br />

Front Ferrules<br />

Back Ferrules<br />

Union (Low Dead Volume)<br />

Unions<br />

1/16" 10 55006 10 55196<br />

1/8" 10 55007 10 55197<br />

1/4" 10 55013 10 55093<br />

1/16" 10 55014 10 55094<br />

1/8" 10 55015 10 55095<br />

1/4" 10 55017 10 55097<br />

1/16" ea 55001 ea 55101<br />

1/16" ea 55009 ea 55109<br />

1/8" ea 55010 ea 55110<br />

1/4" ea 55012 ea 55112<br />

Bulkhead Unions<br />

Reducing Unions<br />

1/16" ea 51017 ea 55117<br />

1/8" ea 55018 ea 55118<br />

1/4" ea 55020 ea 55120<br />

1/8" to 1/16" ea 55021 ea 55121<br />

3/16" to 1/16" ea 55022 ea 55122<br />

3/16" to 1/8" ea 55023 ea 55123<br />

1/4" to 1/16" ea 55024 ea 55124<br />

1/4" to 1/8" ea 55025 ea 55125<br />

284 www.discoverysciences.com


gas chromatography<br />

Swagelok ® Fittings (continued)<br />

Swagelok ® Fittings (continued)<br />

Brass<br />

Part No.<br />

Stainless Steel<br />

Part No.<br />

Description Dimensions Qty.<br />

Qty.<br />

Female Pipe Thread Connectors (Tube to FPT)<br />

1/8" to 1/4" FPT ea 55047 ea 55147<br />

3/16" to 1/8" FPT ea 55048 ea 55148<br />

1/4" to 1/8" FPT ea 55049 ea 55149<br />

1/4" to 1/4" FPT ea 55050 ea 55150<br />

1/4" to 1/2" FPT ea 55052 ea 55152<br />

Male Pipe Thread Connectors (Tube to MPT)<br />

1/16" to 1/16" MPT ea 55033 ea 55133<br />

1/16" to 1/8" MPT ea 55034 ea 55134<br />

1/8" to 1/16" MPT ea 55035 ea 55135<br />

1/8" to 1/8" MPT ea 55036 ea 55136<br />

1/8" to 1/4" MPT ea 55037 ea 55137<br />

1/8" to 3/8" MPT ea 55038 ea 55138<br />

1/4" to 1/8" MPT ea 55042 ea 55142<br />

1/4" to 1/4" MPT ea 55043 ea 55143<br />

1/4" to 3/8" MPT ea 55044 ea 55144<br />

1/4" to 1/2" MPT ea 55045 ea 55145<br />

Tees<br />

1/16" ea 55027 ea 55127<br />

1/8" ea 55028 ea 55128<br />

Crosses<br />

Caps<br />

Plugs<br />

1/4" ea 55030 ea 55130<br />

1/8" ea 55031 ea 55131<br />

1/4" ea 55032 ea 55132<br />

1/16" ea 55085 ea 55185<br />

1/8" ea 55086 ea 55186<br />

1/4" ea 55088 ea 55188<br />

1/16" ea 55089 ea 55189<br />

1/8" ea 55090 ea 55190<br />

1/4" ea 55092 ea 55192<br />

gc accessories | fittings<br />

related products<br />

Need tubing?<br />

See pages 384–391 for a complete<br />

selection of stainless steel, metal, and<br />

polymeric tubing.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

www.discoverysciences.com<br />

285


gas chromatography<br />

gc accessories | injector<br />

Deactivated Injection Liners<br />

Deactivated Injection Liners<br />

Description and Length x o.d.<br />

Injection Liners for Agilent Instruments*<br />

Cup Splitter,<br />

78.5 x 6.3mm<br />

Split/Splitless with Deactivated Quartz Wool,<br />

78.5 x 6.3mm o.d., 4mm i.d.<br />

Splitless,<br />

78.5 x 6.3mm o.d., 4mm i.d.<br />

Quartz Splitless,<br />

78.5 x 6.0mm, 2mm i.d.<br />

Recessed Gooseneck with Deactivated Quartz Wool,<br />

78.5 x 6.3mm, 4mm i.d.<br />

Recessed Gooseneck,<br />

78.5 x 6.3mm, 2mm i.d.<br />

Direct,<br />

78.5 x 6.3mm, 1.5mm i.d.<br />

Injection Liners for Varian ® Instruments<br />

Splitter with Deactivated Quartz Wool, 1075/1077,<br />

72 x 6.3mm, 4mm i.d.<br />

Frit Splitter, 1075/1077,<br />

72 x 6.3mm, 4mm i.d.<br />

Baffle Splitter, 1075/1077,<br />

72 x 6.3mm, 4mm i.d.<br />

Splitless 1075/1077,<br />

74 x 6.3mm, 2mm i.d.<br />

0.8mm SPI 1093/1094,<br />

54 x 4.6mm<br />

0.5mm SPI 1093/1094,<br />

54 x 4.6mm<br />

Injection Liners for PerkinElmer ® Instruments<br />

Split/Splitless Autosystem XL (PSS),<br />

86.2 x 4mm, 2mm i.d.<br />

Split/Splitless Autosystem,<br />

92 x 5.8mm, 4mm i.d.<br />

Injection Liners for Shimadzu ® Instruments<br />

Split 17A with Deactivated Quartz Wool,<br />

95.5 x 5.0mm, 3mm i.d.<br />

Splitless 17A,<br />

95.5 x 5.0mm, 3mm i.d.<br />

Injection Liners for Carlo Erba-Fisons Instruments<br />

Split/Splitless 6000 Series with Deactivated Quartz Wool,<br />

79.5 x 5.0mm, 3mm i.d.<br />

Splitless 6000 Series,<br />

79.5 x 5.0mm, 4mm i.d.<br />

Splitless 6000 Series,<br />

79.5 x 5.0mm, 2mm i.d.<br />

Split 8000 Series,<br />

105 x 8.0mm, 3mm i.d.<br />

best<br />

value<br />

Diagram<br />

5/pk<br />

Part No.<br />

25/pk<br />

Part No.<br />

4827 4829<br />

4924 4928<br />

4934 4936<br />

4963 4964<br />

4960 4961<br />

4938 4957<br />

4968 4969<br />

4971 4972<br />

4974 4975<br />

4978 4979<br />

4981 4982<br />

4984 4985<br />

4987 4988<br />

8618810 —<br />

4798 4800<br />

4750 4752<br />

4756 4758<br />

4744 4746<br />

4854 4855<br />

4851 4852<br />

4786 4788<br />

related products<br />

Don't forget septa!<br />

See pages 289–292 for a complete selection of septa.<br />

286 www.discoverysciences.com


gas chromatography<br />

Deactivated SGE FocusLiners<br />

Deactivated SGE FocusLiners<br />

Description and Length x o.d.<br />

for Agilent Instruments*<br />

FocusLiner,<br />

78.5 x 6.3 x 4mm i.d.<br />

Tapered FocusLiner,<br />

78.5 x 6.3 x 4mm i.d.<br />

FAST FocusLiner,<br />

78.5 x 6.3 x 2.3mm i.d.<br />

Tapered FAST FocusLiner,<br />

78.5 x 6.3 x 2.3mm i.d.<br />

for Varian ® Injector Models 1075/1077<br />

FocusLiner,<br />

72 x 6.3 x 4mm i.d.<br />

Tapered FocusLiner,<br />

74 x 6.3 x 4mm i.d.<br />

FocusLiner w/Top Restriction,<br />

72 x 6.3 x 4mm i.d.<br />

FAST FocusLiner,<br />

72 x 6.3 x 2.3mm i.d.<br />

for Varian ® Injector Models 1078/1079<br />

FocusLiner,<br />

54 x 5 x 3.4mm i.d.<br />

Tapered FocusLiner,<br />

54 x 5 x 3.4mm i.d.<br />

for Shimadzu ® 17A<br />

FocusLiner,<br />

95 x 5 x 3.4mm i.d.<br />

Tapered FocusLiner,<br />

95 x 5 x 3.4mm i.d.<br />

for Shimadzu ® 14/15A/16<br />

FocusLiner,<br />

99 x 5 x 3.4mm i.d.<br />

Tapered FocusLiner,<br />

99 x 5 x 3.4mm i.d.<br />

for PerkinElmer ® Autosystem<br />

FocusLiner,<br />

86.2 x 4 x 2mm i.d.<br />

FocusLiner,<br />

92 x 6.2 x 4mm i.d.<br />

Tapered FocusLiner,<br />

92 x 6.2 x 4mm i.d.<br />

for ThermoQuest Model 8000/TRACE<br />

FocusLiner,<br />

105 x 8 x 5mm i.d.<br />

Tapered FocusLiner,<br />

105 x 8 x 5mm i.d.<br />

*Also compatible with Varian ® model CP-1177 Split/Splitless injection port.<br />

Diagram<br />

5/Pk<br />

Part No.<br />

25/Pk<br />

Part No.<br />

85474 85480<br />

85481 85574<br />

85605 85606<br />

85607 —<br />

85477 —<br />

85484 —<br />

85633 —<br />

85634 —<br />

85437 —<br />

85635 —<br />

85476 —<br />

85483 —<br />

85608 —<br />

85630 —<br />

8618809 —<br />

85478 —<br />

85482 —<br />

85631 —<br />

85632 —<br />

gc accessories | injector<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

www.discoverysciences.com<br />

287


gas chromatography<br />

gc accessories | injector<br />

GC O-rings<br />

• Thermally stable<br />

• No bleed<br />

• Suitable for GC/MS<br />

Graphite O-rings may replace the Viton ® or silicone O-rings<br />

normally used to seal the Agilent 5890 Split and Splitless<br />

injection liners. Splitless liners have an internal diameter of<br />

6.5mm and split liners have an internal diameter of 6.35mm.<br />

Specifications<br />

Property Graphite Silicone PTFE Viton ®<br />

Max. Temp.: 450°C 230°C 230°C 200°C<br />

Chem. Rest.: Good Good Superb Superb<br />

Durability: Superb Moderate Superb Good<br />

Bleed: None Medium Low Low<br />

Color: Black Red White Black<br />

O-rings<br />

Size Qty. Part No.<br />

Graphite GC O-rings (450°C Limit)<br />

1/4" (6.5mm i.d.) 10 7160<br />

1/4" (6.35mm i.d.) 10 7176<br />

Silicone O-rings (230°C Limit)<br />

1/8" 100 7020<br />

3/16" 100 7021<br />

1/4" 100 7022<br />

PTFE O-rings (230°C Limit)<br />

1/8" 100 7023<br />

3/16" 100 7024<br />

1/4" 100 7025<br />

Viton ® O-rings (200°C Limit)<br />

1/8" 100 7017<br />

3/16" 100 7018<br />

1/4" 100 7019<br />

4639<br />

Injector Supplies for<br />

Agilent 5890/6890 GCs<br />

Inlet Seals for Agilent 5890/6890 GCs are available<br />

either stainless steel (similar to<br />

Agilent part no. 18740-20880)<br />

or gold plated (similar to Agilent<br />

part no. 18740-20885). Washers<br />

are included with the inlet seals.<br />

The Reducing Nut for Agilent 5890/6890 GCs is made from<br />

stainless steel and is similar to Agilent part no. 18740-20800.<br />

Injector Supplies for Agilent 5890/6890 GCs<br />

Description Qty. Part No.<br />

Inlet Seal, stainless steel (0.8mm hole) 1 15146<br />

10 151461<br />

25 151462<br />

Inlet Seal, gold plated (0.8mm hole) 1 15147<br />

10 151471<br />

25 151472<br />

Reducing Nut Replacement for Agilent 5890/6890 1 15145<br />

Washers, stainless steel (0.375" o.d.) 10 15148<br />

MSD Source Nut, brass 1 15104<br />

Accessories for<br />

Agilent and Varian ®<br />

Capillary Systems<br />

Agilent nuts are available in both standard and “deep well”<br />

versions, with either standard wrench flats or knurled for easy<br />

wrench-free fingertight connections. The deep well nuts have<br />

2.4mm deep ferrule wells to accommodate standard capillary<br />

ferrules, and the standard type has a 1.65mm deep ferrule<br />

well for Agilent-type capillary ferrules.<br />

6650<br />

6651<br />

related products<br />

Don't forget septa!<br />

See pages 289–292 for a complete selection of septa.<br />

Accessories for Agilent and Varian ®<br />

Description Qty. Part No.<br />

Capillary Nuts<br />

Capillary Nuts for Varian ® 2 154740<br />

Capillary Nuts for Agilent 2 154780<br />

Wrench-Free Capillary Nuts for Agilent 2 154785<br />

Deep Well Capillary Nuts for Agilent 2 154781<br />

Wrench-Free Deep Well for Agilent 2 154782<br />

Graphite Ferrules for Agilent<br />

Graphite Ferrules, 0.5mm Hole* 10 1547901<br />

Graphite Ferrules, 1.0mm Hole** 10 1548001<br />

Wrench<br />

5/16" x 1/4" Open-End Wrench ea 1998<br />

*For 0.25 and 0.32mm i.d. Capillary Column.<br />

**For 0.45 and 0.53mm i.d. Capillary Column.<br />

288 www.discoverysciences.com


gas chromatography<br />

Septa Introduction<br />

How to Select a Septum for Your Application<br />

With so many septa to choose from, choosing a septum for<br />

your application can be a confusing task. There are a number<br />

of criteria you need to consider when selecting a septum.<br />

Make and Model of Gas Chromatograph<br />

This will determine what size of septum you need.<br />

<strong>Grace</strong> carries a full range of septum sizes to fit most gas<br />

chromatographs.<br />

Performance<br />

A high-performance, low-bleed septum is desirable so that<br />

septa bleed does not interfere with the chromatography<br />

of your sample. Keep in mind that all septa bleed to some<br />

extent. The amount of bleed visible to the detector is affected<br />

by several factors which include:<br />

• The composition and pretreatment of the septum material<br />

• The sensitivity setting of the detector amplifier<br />

• The type of detector<br />

• The injection port setting<br />

• Isothermal or temperature programming<br />

• The type of injection (direct, splitless, split, etc.)<br />

Choose a high-performance septum such as ThermoRed<br />

or XLB septa to minimize septa bleed.<br />

Injection Port Temperature<br />

The temperature of the septum never reaches the injection<br />

port temperature setting. The center of the injector heated<br />

zone, where the sample is deposited, is regulated to<br />

correspond to the injector port setting. Be sure to select a<br />

septum with a maximum temperature that exceeds your<br />

injection port temperature.<br />

Penetration/Resealing Qualities<br />

Ideally, you want a septum that is soft and easily penetrated<br />

by a syringe needle and has excellent resealing properties.<br />

This will prevent you from bending syringe needles and<br />

coring of the septum to give you longer septum life. Excellent<br />

resealing properties will prevent leaks that might adversely<br />

affect your chromatography or damage your analytical<br />

column.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

Septa Specifications<br />

Actual Size Drawing Measurement Chromatograph<br />

1/4"<br />

(6mm)<br />

3/8"<br />

(9.5mm)<br />

7/16"<br />

(11mm)<br />

1/2"<br />

(12.5mm)<br />

21/32"<br />

(17mm)<br />

*Use cylindrical plug septa, see page 291.<br />

Shimadzu*, SRI*<br />

Antek, Finnigan 9100, 9600, Gow-Mac,<br />

Agilent 5700, 5880 & 5900, IBM,<br />

Packard 427-433, Pye-Unicam (early<br />

models), Varian (except capillary inj.),<br />

Tracor 550, 560<br />

Carle, Agilent 5890,6850,6890. P-E<br />

Sigma, 900, 990, 3920, 8300, 8400,<br />

8500 Autosys, Varian (capillary injector),<br />

SPI, Varian 1078/1079<br />

Fisons/Carlo Erba, Finnigan 9500,<br />

Agilent 5750 and earlier models,<br />

Packard 409-421, Tracor 220, 222, 540<br />

Fisons/Carlo Erba 8000 Series, CE<br />

TRACE GC<br />

Septa Selection Guide<br />

Product Max. Temp. Color Durometer* Low Bleed<br />

ThermoRed 300°C Red 50–55 Excellent<br />

XLB 350°C Green 50–55 Excellent<br />

HT-X High<br />

350°C Blue 50–60 Excellent<br />

Performance<br />

General Purpose Blue 250°C Blue 40–45 Good<br />

Cylindrical Half-Hole 250°C Blue 50–55 Very Good<br />

Cylindrical Three-Layer 200°C Red 50–55 Excellent<br />

Three-Layer 300°C Red/ 50–55 Good<br />

White<br />

Four-Layer 225°C Red/ 50–55 Good<br />

White<br />

Microsep ®<br />

250°C Off-White 25–35 Good<br />

PTFE-lined<br />

Microsep ® Low-Bleed 250°C Yellow/ 25–35 Very Good<br />

PTFE-lined<br />

Off-White<br />

High-Temperature 350°C Red 50 Excellent<br />

Ultra Low-Bleed<br />

*Durometer—Hardness of the silicone material. The lower the number, the softer<br />

the material.<br />

4610<br />

gc accessories | septa<br />

www.discoverysciences.com 289


gas chromatography<br />

Septa<br />

3- and 4-Layer Septa<br />

• Excellent sealing characteristics<br />

• Maximum temperature of 300ºC (3-layer) and<br />

225ºC (4-layer)<br />

The 3-Layer Septa consists of a layer of red silicone rubber,<br />

a layer of translucent soft silicone rubber and another layer<br />

of red silicone rubber. The 4-Layer Septa is the same but with<br />

a 10-mil (0.010") PTFE facing.<br />

Microsep ® PTFE-Lined Septa<br />

• Maximum temperature of 250ºC<br />

• Off-white silicone rubber with an ivory PTFE backing<br />

4593<br />

gc accessories | septa<br />

3-Layer Septa<br />

4595 4594<br />

4-Layer Septa<br />

3- and 4-Layer Septa<br />

Size (o.d.) Qty. Part No.<br />

3-Layer Septa<br />

3/8" (9.5mm) 100 7836<br />

7/16" (11mm) 100 7838<br />

1/2" (12.5mm) 100 7840<br />

4-Layer Septa<br />

3/8" (9.5mm) 100 7844<br />

7/16" (11mm) 100 7846<br />

1/2" (12.5mm) 100 7848<br />

High-Temperature, Ultra Low-Bleed Septa<br />

• Long life, minimum of 450 injections<br />

• Maximum temperature of 350ºC<br />

• Made of 100% premium silicone<br />

• Guide hole in center<br />

• Precision molded<br />

new<br />

Microsep ® PTFE-Lined Septa<br />

Size (o.d.) Qty. Part No.<br />

0.250" (6mm) 12 75801<br />

0.250" (6mm) 100 79391<br />

0.281" (7mm) 12 75810<br />

0.355" (9mm) 12 75803<br />

0.375" (9.5mm) 12 75804<br />

0.375" (9.5mm) 100 79411<br />

0.394" (10mm) 12 75805<br />

0.394" (10mm) 100 79451<br />

0.438" (11mm) 12 75807<br />

0.438" (11mm) 100 79471<br />

0.469" (12mm) 12 75813<br />

0.500" (12.5mm) 12 75806<br />

0.500" (12.5mm) 100 79491<br />

Microsep ® Low-Bleed PTFE-Lined Septa<br />

• Maximum temperature of 250ºC<br />

• Off-white silicone septa with yellow PTFE backing<br />

7434<br />

4591<br />

High-Temperature, Ultra Low-Bleed Septa<br />

Size (o.d.) Qty. Part No.<br />

3/8" (9.5mm) 50 8619148<br />

0.394" (10mm) 50 8619149<br />

7/16" (11mm) 50 8619160<br />

Shimadzu ® Plug 50 8619144<br />

Microsep ® Low-Bleed PTFE-Lined Septa<br />

Size (o.d.) Qty. Part No.<br />

3/8" (9.5mm) 50 7802<br />

3/8" (9.5mm) 2 x 50 78001<br />

3/8" (9.5mm) 20 x 50 78002<br />

7/16" (11mm) 50 7803<br />

7/16" (11mm) 2 x 50 78011<br />

7/16" (11mm) 20 x 50 78012<br />

1/2" (12.5mm) 50 7806<br />

1/2" (12.5mm) 2 x 50 78041<br />

1/2" (12.5mm) 20 x 50 78042<br />

290<br />

www.discoverysciences.com


gas chromatography<br />

Septa<br />

General Purpose Blue Septa<br />

• Maximum temperature of 250°C<br />

(300°C for short periods)<br />

• Lifetime of up to 150 injections<br />

• Suitable for most GC analysis<br />

General Purpose Blue Septa<br />

Size (o.d.) Qty. Part No.<br />

1/4" (6mm) 100 6512<br />

1/4" (6mm) 10 x 100 65122<br />

3/8" (9.5mm) 100 6514<br />

3/8" (9.5mm) 10 x 100 65142<br />

7/16" (11mm) 100 6518<br />

7/16" (11mm) 10 x 100 65182<br />

1/2" (12.5mm) 100 6520<br />

1/2" (12.5mm) 10 x 100 65202<br />

12" x 12" Sheet ea 6528<br />

4603<br />

XLB Septa<br />

• Maximum temperature to 350°C<br />

• Extremely low bleed<br />

• Superior resealing properties<br />

• Soft, easily penetrated by<br />

syringe needle<br />

XLB Septa<br />

Size (o.d.) Qty. Part No.<br />

1/4" (6mm) 50 15427<br />

3/8" (9.5mm) 50 15428<br />

7/16" (11mm) 50 15429<br />

1/2" (12.5mm) 50 15430<br />

21/32" (17mm) 50 15039<br />

4607<br />

ThermoRed Septa<br />

• Maximum temperature of 300°C<br />

• Packed in glass jars under strict<br />

QC standards to protect from<br />

contaminants<br />

ThermoRed Septa<br />

Size (o.d.) Qty. Part No.<br />

11/32'' (9mm) 25 15129<br />

3/8'' (9.5mm) 25 15131<br />

7/16'' (11mm) 25 15132<br />

1/2" (12.5mm) 25 15141<br />

21/32'' (17mm) 25 15133<br />

Plug Type (For Shimadzu ® and SRI) 25 15134<br />

General Purpose White Septa<br />

• Maximum temperature of 250°C<br />

• Lifetime of over 100 injections<br />

• Designed for use in 90% of all<br />

GC analysis<br />

General Purpose White Septa<br />

Size (o.d.) Qty. Part No.<br />

3/8'' (9.5mm) 50 7812<br />

3/8'' (9.5mm) 2 x 50 78101<br />

7/16'' (11mm) 50 7813<br />

7/16'' (11mm) 2 x 50 78111<br />

1/2" (12.5mm) 50 7816<br />

1/2" (12.5mm) 2 x 50 78141<br />

4608<br />

4605<br />

HT-X High-Performance Septa<br />

• Maximum temperature of 350°C<br />

• Long injection life—over<br />

200 injections<br />

HT-X High-Performance Septa<br />

Size (o.d.) Qty. Part No.<br />

1/4" (6mm) 50 15490<br />

5/16" (8mm) 50 15491<br />

3/8" (9.5mm) 50 15492<br />

7/16" (11mm) 50 15493<br />

21/32" (17mm) 50 154941<br />

1/2" (12.5mm) 50 15494<br />

12" x 12" Sheet ea 15496<br />

Plug Type (For Shimadzu ® and SRI) 50 15498<br />

Cylindrical Septa<br />

• 8mm long x 6mm o.d. with<br />

half-hole<br />

The standard half-hole septa<br />

is red silicone with an upper<br />

temperature limit of 225°C.<br />

Half-Hole Septa Shown Here<br />

3-layer septa features the<br />

shielding and reinforcing properties of PTFE. The plug septa<br />

are low bleed, have an upper temperature limit of 350°C, and<br />

are compatible with Shimadzu ® and SRI.<br />

4604<br />

4597<br />

gc accessories | septa<br />

Standard Blue Septa<br />

• Maximum temperature of 300°C<br />

• Lifetime of over 50 injections<br />

Standard Blue Septa<br />

Size (o.d.) Qty. Part No.<br />

3/8'' (9.5mm) 100 7824<br />

7/16'' (11mm) 100 7826<br />

1/2" (12.5mm) 100 7830<br />

4601<br />

Cylindrical Septa<br />

Size (o.d.) Qty. Part No.<br />

Cylindrical Half-Hole Septa<br />

1/4" (6mm) 25 6524<br />

1/4" (6mm) 4 x 25 6526<br />

3-Layer 1/4" (6mm) 50 9602<br />

Cylindrical Plug Septa for Shimadzu ® and SRI 50 15498<br />

www.discoverysciences.com 291


gas chromatography<br />

gc accessories | septa<br />

Merlin Microseal ® Septum<br />

• Lasts for thousands of<br />

injections<br />

• No instrument<br />

modification needed<br />

• Installation as easy as<br />

changing a standard<br />

septum<br />

• High-pressure model<br />

allows operation up to<br />

100psig<br />

The Merlin Microseal ® septum is a long-life replacement for<br />

the septum and septum nut on the capillary inlet system of<br />

an Agilent GC. It incorporates two sequential seals to provide<br />

a much longer period of use between seal changes. Use the<br />

Merlin Microseal ® septum with the 7673 Autosampler to allow<br />

many more samples to be run unattended while reducing the<br />

risk of lost or compromised data caused by septum leaks or<br />

fragmentation. It also allows for easier manual injections.<br />

The Microseal ® septum lasts longest when a syringe needle<br />

with a truncated cone shaped tip is used. It may also be used<br />

with the standard 0.63mm diameter (0.026", 23-gauge) needle<br />

recommended for use with the 7673 Autosampler.<br />

Merlin Microseal ® Septum*<br />

Description<br />

Part No.<br />

Microseal ® Septum Kits<br />

For Agilent GCs<br />

Microseal ® Nut and 2 Septa 80060<br />

Microseal ® Nut and 1 Septum 80062<br />

Microseal ® High-Pressure Septum Kits<br />

Standard Kit, Nut and 2 Septa 80190<br />

Starter Kit, Nut and 1 Septum 80192<br />

For Varian ® 1078 and 1079 GCs with SPME Injector<br />

Varian ® Kit, Nut with Start Switch, 1 Septum and O-ring 80031<br />

Replacement Parts<br />

For Agilent GCs<br />

Microseal ® Septum, ea 80063<br />

Microseal ® High-Pressure Septum, ea 80194<br />

Microseal ® High-Pressure Nut, ea 80196<br />

For Varian ® 1078 and 1079 GCs with SPME Injector<br />

Microseal ® High-Pressure Septum, ea 80035<br />

*Regular Merlin Microseal ® has a 30psig limit. High-Pressure Merlin Microseal ® has a<br />

100psig limit.<br />

5070<br />

Septa Accessories<br />

Septa-Out<br />

Safely extract cylindrical septa without<br />

the danger of breaking your glass<br />

column or sampling bulb port.<br />

Septa-Out<br />

Description<br />

Part No.<br />

Septa-Out 6412<br />

Heat-Resistant Gloves<br />

• Protect your hands from burns<br />

• Heavyweight cotton/Kevlar ®<br />

combination<br />

Knit construction offers superior comfort<br />

and lessens hand fatigue. Gloves are<br />

ambidextrous and feature a glove-withina-glove<br />

design.<br />

Heat-Resistant Gloves<br />

Description Qty. Part No.<br />

Heat-Resistant Gloves pr 2906<br />

Inlet Pressure Gauge<br />

Insert the needle directly into the inlet of any gas<br />

chromatograph for direct pressure measurement.<br />

The small, 0.028" o.d. needle permits repeated<br />

inlet pressure checks without damage to the<br />

septum.<br />

Inlet Pressure Gauge<br />

Description<br />

Part No.<br />

0–30psig 86805<br />

0–60psig 86806<br />

0–100psig 86807<br />

0–200psig 86808<br />

Replacement Needle Assembly 18260<br />

4585<br />

4582<br />

4588<br />

Septum Remover<br />

90º hooked point allows for safe septum removal. Aluminum<br />

body. 8" length.<br />

Septum Remover<br />

Description<br />

Part No.<br />

Septum Remover 24030<br />

4584<br />

Septum Needle Guide<br />

This septum needle guide helps reduce<br />

bent syringe needles and extends<br />

septum life. With the septum needle<br />

guide you get double leak protection.<br />

A cylindrical septum acts as a double seal should your<br />

primary septum start leaking. Needle guide is self-centering<br />

to aid in on-column injection.<br />

Septum Needle Guide<br />

Description<br />

Part No.<br />

Needle Guide, 7/16" x 20 Thread* 6401<br />

Needle Guide, 7/16" x 24 Thread 6403<br />

Needle Guide without Nut 6400<br />

Drill Bit for Enlarging Hole 6402<br />

Replacement Cylindrical Septa, 25/pk 6524<br />

*Fits most injection ports including: PE-3920 and Sigma Series; HP5700, 5800, and<br />

6900 Series (5890 and 6890).<br />

4583<br />

292<br />

www.discoverysciences.com


gas chromatography<br />

Flow Control Valves<br />

Parker Toggle Valves<br />

These forged-body valves are positive, soft-seat<br />

shut-off valves designed for quick opening and<br />

closing. Shut-off force is constant because of<br />

the spring load. The handle locks in the open Part No. 2328<br />

or closed position. A TFE stem tip provides a<br />

leak-tight seal. The maximum working pressure is 250psig;<br />

maximum temperature is 93°C. They are made of brass or<br />

316 stainless steel with TFE seat, fluoroelastomer polymer<br />

packing and nylon handle. All other parts are 316 stainless<br />

steel.<br />

Parker Toggle Valves<br />

Description<br />

Part No.<br />

1/8", Brass 2328<br />

1/4", Brass 2332<br />

1/8", Stainless Steel 2336<br />

1/4", Stainless Steel 2340<br />

Nupro ® and Whitey ® Plug and Ball Valves<br />

The plug valves are constructed of brass or stainless steel<br />

and TFE. The compact plug valves can be used up to<br />

3000psig and the temperature limit is 200°C. They have<br />

a plug orifice of 0.172" for high flow capacity.<br />

best<br />

seller<br />

The 2-way and 3-way ball valves can be used up to 65°C and<br />

are pressure-rated to 2500psig. Both can be panel-mounted<br />

in a 19/32" hole. The 1/8" valves have a 0.093" orifice while<br />

the 1/4" valves have a 0.125" orifice.<br />

5232 5233 5234<br />

Part No. 14320 Part No. 14318 Part No. 14316<br />

Nupro ® and Whitey ® Plug and Ball Valves<br />

Plug Valve<br />

Part No.<br />

2-Way Ball Valve<br />

Part No.<br />

3-Way Ball Valve<br />

Part No.<br />

Description<br />

1/8", Brass 14320 14318 14316<br />

1/4", Brass 14319 14317 14315<br />

1/8", Stainless Steel 16013 16017 16022<br />

1/4", Stainless Steel 16015 16019 16024<br />

Nupro ® and Whitey ® Fine Metering Valves<br />

These valves give extremely fine control in the 0–400cc/min<br />

gas flow range. The maximum pressure rating is 1000psig<br />

at 70°C. The maximum temperature limit for brass valves is<br />

150°C; 200°C for stainless steel. They can be panel mounted<br />

in a 37/64" hole.<br />

Nupro ® and Whitey ® Fine Metering Valves<br />

Description<br />

Straight Pattern<br />

Part No.<br />

Angle Pattern<br />

Part No.<br />

1/8", Brass 8600 8608<br />

1/4", Brass 8602 8610<br />

1/8", Stainless Steel 8604 8612<br />

1/4", Stainless Steel 8606 8614<br />

5225<br />

Hoke ® Toggle Valves<br />

These valves feature a simple, reliable,<br />

low-maintenance design that is well suited for<br />

a wide variety of applications. They are made<br />

of brass or stainless steel and include longlasting<br />

fluoroelastomer polymer seat and o-ring Part No. 12131<br />

5259<br />

packing for positive pressure or vacuum applications.<br />

The maximum operating pressure is 200psig and the<br />

maximum operating temperature is 149°C.<br />

Hoke ® Toggle Valves<br />

Description<br />

Part No.<br />

Straight Toggle Valves<br />

1/8", Brass 12131<br />

1/4", Brass 12133<br />

1/8", Stainless Steel 12132<br />

1/4", Stainless Steel 12134<br />

Hoke ® Plug and Ball Valves<br />

The plug valves are constructed of brass or stainless steel<br />

and PTFE. They have an upper pressure limit of 3000psig<br />

and an upper temperature limit of 205°C. They have a plug<br />

orifice of 0.093".<br />

The 2-way ball valves are made of brass or stainless steel<br />

and PTFE. They have an upper temperature limit of 179°C<br />

and an upper pressure limit of 1500psig. The 1/8" version has<br />

a 0.093" orifice while the 1/4" version has a 0.187".<br />

The 3-way ball valves are made of brass or stainless steel<br />

and PTFE/Nylatron ® . They have an upper pressure limit of<br />

500psig and an upper temperature limit of 179°C. Both sizes<br />

have a 0.187" orifice.<br />

5262 5260 5263<br />

Part No. 12126 Part No. 12119 Part No. 12123<br />

Hoke ® Plug and Ball Valves<br />

Plug Valve 2-Way Ball Valve 3-Way Ball Valve<br />

Description<br />

Part No.<br />

Part No.<br />

Part No.<br />

1/8", Brass 12126 12118 12122<br />

1/4", Brass 12128 12120 12124<br />

1/8", Stainless Steel 12127 12119 12123<br />

1/4", Stainless Steel 12129 12121 12125<br />

Plug Valve Repair Kit — — 12130<br />

Hoke ® Fine Metering Valves with Vernier Knob<br />

These valves allow reproducibility of precise flows. All valves<br />

use a TFE seat seal and packing. Brass valves are rated at<br />

3000psig; stainless steel at 5000psig. Temperatures up to<br />

230°C can be used but at lower pressures.<br />

Hoke ® Fine Metering Valves<br />

Straight Pattern<br />

Part No.<br />

Angle Pattern<br />

Part No.<br />

Description<br />

1/8", Brass 86001 86081<br />

1/4", Brass 86021 86101<br />

1/8", Stainless Steel 86041 86121<br />

1/4", Stainless Steel 86061 86141<br />

gc accessories | valves<br />

www.discoverysciences.com 293


gas chromatography<br />

Valco ® Sampling/<br />

Switching Valves<br />

Zero-Volume Fittings Allow for Direct .<br />

Valve Connections<br />

• Easily adapt to any type of tubing<br />

• Eliminate pressure surges during sample injections<br />

• Carefully leak tested<br />

Accessories for Valco ®<br />

Sampling/Switching Valves<br />

Stainless Steel Sample Loops<br />

Valco ® Stainless Steel Sample Loops*<br />

Loop Size<br />

Use with 1/16" Valves<br />

Part No.<br />

Use with 1/8" Valves<br />

Part No.<br />

15µL 91056 91106<br />

25µL 91057 91107<br />

50µL 91058 91108<br />

100µL 91059 91109<br />

250µL 91050 91100<br />

500µL 91051 91101<br />

1.0mL 91052 91102<br />

2.0mL 91053 91103<br />

5.0mL 91054 91104<br />

10.0mL 91055 91105<br />

*One pair of nuts and ferrules are included.<br />

gc accessories | valves<br />

What’s included: zero-volume fittings, mounting<br />

bracket, and handle.<br />

Valco ® Sampling/Switching Valve Specifications<br />

Valve Body: Type 316 Stainless Steel<br />

Valve Seal:<br />

Carbon-filled PTFE (Medium-Temp.) or<br />

Carbon-filled Polyimide (High-Temp.)<br />

Outlet Fitting: 1/16" zero-volume fittings or<br />

1/8" zero-volume fittings (included)<br />

Max. Pressure: 400psig<br />

Max. Temp:<br />

175°C for medium-temperature valves<br />

300°C for high-temperature valves*<br />

Active Ports: 3, 4, 6, 8, or 10 Ports (Note: a 10-port valve can<br />

be used as a 6- or 8-port valve)<br />

Mounting:<br />

Valves supplied with angle mounting brackets for<br />

mounting on the side of the instruments or they<br />

can be flush mounted. Valves are tapped with<br />

8-32TPI holes. Most GCs are designed to accept<br />

these valves.<br />

*Cannot be used below 200°C.<br />

4678<br />

Zero-Volume Fittings<br />

Column<br />

Inlet<br />

Zero-Volume Fittings<br />

Valve Body<br />

Use with 1/16" Valves<br />

Part No.<br />

Sample<br />

Loop<br />

Use with 1/8" Valves<br />

Part No.<br />

Description<br />

Nuts, 5/pk 458015 458025<br />

Ferrules, 5/pk 458125 458155<br />

1577<br />

Valco ® Sampling/Switching Valves*<br />

Diagram Ports Fittings<br />

Medium-Temp.<br />

Valve Part No.<br />

High-Temp.<br />

Valve Part No.<br />

0345<br />

3-Port 1/16" Zero-Volume 9099 39099<br />

1/8" Zero-Volume 9101 39101<br />

0346<br />

2102<br />

2103<br />

4-Port 1/16" Zero-Volume 9103 39103<br />

1/8" Zero-Volume 9104 39104<br />

6-Port 1/16" Zero-Volume 9105 39105<br />

1/8" Zero-Volume 9110 39110<br />

8-Port 1/16" Zero-Volume 9115 39115<br />

1/8" Zero-Volume 9116 39116<br />

10-Port 1/16" Zero-Volume 9119 39119<br />

2104 1/8" Zero-Volume 9120 39120<br />

*By special order, valves can be fabricated from Hastalloy C. Call for pricing information.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

more info<br />

For more detailed list of Valco ® Accessories, visit our website at<br />

www.discoverysciences.com.<br />

294<br />

www.discoverysciences.com


General<br />

Chromatography<br />

SPE . . . . . . . . . . . . . . . . . . . . . . . 296–316<br />

SPE Introduction . . . . . . . . . . . . . . . . . . . 296–299<br />

Alltech ® SPE Sorbent Introduction . . . . . . . . . . 300–301<br />

Alltech ® Extract-Clean and Ultra-Clean Columns. 302–306<br />

Reversed-Phase . . . . . . . . . . . . . . . . . . . . . . . 302<br />

Normal-Phase . . . . . . . . . . . . . . . . . . . . . . . . . 303<br />

Ion-Exchange . . . . . . . . . . . . . . . . . . . . . . . . . 304<br />

Specialty . . . . . . . . . . . . . . . . . . . . . . . . . 305–306<br />

Alltech ® Maxi-Clean Cartridges . . . . . . . . . . . .307–310<br />

Reversed-Phase . . . . . . . . . . . . . . . . . . . . . . . 308<br />

Normal-Phase . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

Ion-Exchange . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

Alltech ® 96-Well Plates. . . . . . . . . . . . . . . . . . . 311<br />

Vydac ® SPE Columns . . . . . . . . . . . . . . . . . . . 311<br />

<strong>Grace</strong>Pure SPE Sorbents and Columns . . . . . . 312–313<br />

Vacuum Manifolds . . . . . . . . . . . . . . . . . . 314–315<br />

SPE Accessories . . . . . . . . . . . . . . . . . . . . . 316<br />

Filtration . . . . . . . . . . . . . . . . . . . .317–322<br />

Filtration Introduction. . . . . . . . . . . . . . . . . 317–318<br />

Syringe Filters . . . . . . . . . . . . . . . . . . . . 319–320<br />

Other Filters and Accessories . . . . . . . . . . . . 321–322<br />

Standards and Reagents . . . . . . . . . . .323–335<br />

Derivatization Reagents . . . . . . . . . . . . . . . 323–327<br />

Ion-Pair Reagents . . . . . . . . . . . . . . . . . . . . . 328<br />

Gas Standards . . . . . . . . . . . . . . . . . . . . 329–331<br />

FAME & Hydrocarbon Standards . . . . . . . . . . 332–333<br />

IC Standards and Buffers . . . . . . . . . . . . . . 334–335<br />

Syringes . . . . . . . . . . . . . . . . . . . .336–347<br />

Introduction. . . . . . . . . . . . . . . . . . . . . . 336–336<br />

Hamilton ® Syringes. . . . . . . . . . . . . . . . . . 337–342<br />

VICI ® Precision Syringes. . . . . . . . . . . . . . . . . 343<br />

SGE ® Syringes . . . . . . . . . . . . . . . . . . . . 344–346<br />

Popper Syringes and Syringe Accessories . . . . . . . . 347<br />

Vials. . . . . . . . . . . . . . . . . . . . . . . 348–383<br />

Introduction. . . . . . . . . . . . . . . . . . . . . . 348–353<br />

8 x 40mm Vials. . . . . . . . . . . . . . . . . . . . . . 354<br />

12 x 32mm Vials . . . . . . . . . . . . . . . . . . . 355–361<br />

15 x 45mm Vials . . . . . . . . . . . . . . . . . . . 362–363<br />

Headspace and Specialty Vials . . . . . . . . . . . 364–367<br />

Storage Vials, Shell Vials, and Closures. . . . . . . 368–375<br />

EPA and I-CHEM Vials . . . . . . . . . . . . . . . 376–378<br />

96-Well Products . . . . . . . . . . . . . . . . . . . . . 379<br />

Vial Accessories . . . . . . . . . . . . . . . . . . . 380–383<br />

Tubing . . . . . . . . . . . . . . . . . . . .384–391<br />

Organizers and Tools . . . . . . . . . . . . .392–393


general chromatography<br />

solid phase extraction<br />

SPE Introduction<br />

How to Choose an SPE Product<br />

1. Characterize the Sample<br />

Factors such as the analyte’s polarity relative to the<br />

matrix, the presence of charged functional groups,<br />

solubility, molecular weight, etc., determine how strong<br />

the analyte is retained by the packed bed.<br />

2. Select a Retention Strategy<br />

There are two basic methods for sample treatment:<br />

a. Select the packing bed to retain the desired analyte.<br />

The contaminants are washed off and the desired<br />

analyte is then eluted for analysis.<br />

b. Select the packing bed to retain the contaminants<br />

and the desired analyte passes directly through.<br />

3. Select the Proper Packing Type<br />

Select the proper packing type for the cleanest extract<br />

with the highest recovery.<br />

a. Reversed-phase packings are hydrophobic, silica-based<br />

materials that retain moderately polar to non-polar<br />

compounds from a polar matrix while washing off polar<br />

interferences. Or you can retain non-polar contaminants<br />

while the polar compounds pass through unretained.<br />

b. Normal-phase packings are hydrophilic, silica-based<br />

materials that retain polar compounds from a nonpolar<br />

matrix while washing off non-polar interferences.<br />

Or you can retain polar contaminants while non-polar<br />

compounds pass through unretained.<br />

c. Ion-exchange resins retain charged compounds or<br />

remove ionic interferences.<br />

4. Optimize Conditions for Best Results<br />

Select proper bed size and suitable conditioning, wash<br />

and elution solvents.<br />

a. Poor sample recovery often occurs when the packed<br />

bed dimensions are not optimized. An excessive bed<br />

weight results in incomplete elution while an insufficient<br />

bed weight results in incomplete retention.<br />

b. Consider the solvent strength relative to the packing<br />

material. The final conditioning solvent should be<br />

weak so it doesn’t act as an eluting solvent. Buffers<br />

should be used to control ionization of potentially<br />

charged compounds.<br />

c. Wash solvents should remove weakly retained<br />

interferences without being strong enough to elute<br />

the analyte.<br />

d. Elution solvents should be strong enough to completely<br />

elute an analyte in a small volume (1–2mL).<br />

Solid-Phase Processing Methods<br />

By Syringe<br />

Process individual<br />

samples via luer hub<br />

syringe. Connect<br />

syringe directly to SPE<br />

cartridges or to SPE<br />

columns via adapters<br />

found on page 316.<br />

By Vacuum<br />

Manifold<br />

Process multiple<br />

samples on a vacuum<br />

manifold using<br />

SPE columns. Extend<br />

volume via reservoirs.<br />

Products found on<br />

pages 314–316.<br />

By Filter Flask<br />

Process large volume<br />

samples by placing<br />

SPE tube with an<br />

online filtration system.<br />

See page 130.<br />

For Environmental Applications<br />

Recommended SW-846 Cleanup Methods<br />

Analyte Group<br />

EPA .<br />

Method No.<br />

Recommended .<br />

SPE Sorbents<br />

Aniline and Derivatives 3620 C18<br />

Chlorinated Pesticides 3620 C18, Florisil ®<br />

Chlorinated Hydrocarbons 3620 C18, Phenyl<br />

Haloethers 3620 C18, Florisil ®<br />

Nitroaromatics and Cyclic<br />

3620 DVB, IC-RP<br />

Ketones<br />

Nitrosamines 3610, 3620 C18<br />

Organochlorine Pesticides 3620 C18, Florisil ®<br />

Organophosphorus Pesticides 3620 Florisil ® , Carbograph<br />

PCB’s 3620, 3630 C18, SCX, Carbograph<br />

Petroleum Waste 3611 Alumina<br />

Phenols 3630 C18, Phenyl<br />

Phthalate Esters 3610, 3620 C18, DVB<br />

Polynuclear Aromatic<br />

Hydrocarbons<br />

3630 C18, Phenyl<br />

4915<br />

6275<br />

5953<br />

296<br />

www.discoverysciences.com


general chromatography<br />

SPE Introduction<br />

SPE Method Development<br />

SPE method development typically contains four steps:<br />

Step 1: Condition<br />

The conditioning step is composed of two substeps; the first activates<br />

the sorbent ligands, the second equilibrates the sorbent bed.<br />

Step 2: Load<br />

In the load step, sample is applied to the SPE device. Matrix and flow rate<br />

are optimized to quantitatively retain target analytes.<br />

Step 3: Wash<br />

In the wash step, choose a solvent that elutes impurities but retains target<br />

analytes. Often the second conditioning solvent is a suitable wash solvent.<br />

Step 4: Elute<br />

The elution step ideally removes all target analytes with minimal solvent<br />

to maximize sensitivity. Sometimes this requires a combination of solvents<br />

to break both the primary and secondary interactions.<br />

7055<br />

Reversed-Phase Extraction Procedure<br />

Mechanism: Bind moderately polar to non-polar<br />

compounds from a polar sample matrix<br />

Normal-Phase Extraction Procedure<br />

Mechanism: Bind polar compounds from<br />

a non-polar sample matrix<br />

Ion-Exchange Extraction Procedure<br />

Mechanism: Bind charged (negative/anionic<br />

or positive/cationic) compounds<br />

General Method Development Procedures<br />

Step 1—Condition Step 2—Load Step 3—Wash Step 4—Elute<br />

Methanol followed Process sample at a Water or water: Methanol or acetonitrile. May need to<br />

by water<br />

flow rate of 1–5mL/min methanol (95:5) add strong acid or base to organic solvent<br />

to break secondary interactions.<br />

IPA followed<br />

by hexane<br />

Methanol:water<br />

(50:50) followed by<br />

low ionic strength<br />

(0.1M) buffer<br />

Process sample at a<br />

flow rate of 1–5mL/min<br />

Apply slowly: less than<br />

or equal to 1mL/min ion<br />

exchange kinetics are<br />

slower than reversedor<br />

normal-phase<br />

Hexane or<br />

hexane:IPA<br />

(98:2)<br />

Methanol:low<br />

ionic strength<br />

(0.1M) buffer<br />

(10:90)<br />

IPA, ethyl acetate, acetone, or hexane:<br />

IPA (50:50)<br />

High ionic strength (0.5M–1.0M) buffer<br />

or modify pH such that the analyte is<br />

uncharged. May need to add organic<br />

to break hydrophobic interactions.<br />

Recommended Usage Guidelines*<br />

Bed Size: 50mg 100mg 200mg 500mg 500mg 1000mg 2000mg 5000mg 10,000mg<br />

Sorbent Retention Capacity: 2.5mg 5mg 10mg 25mg 25mg 50mg 100mg 250mg 500mg<br />

Condition Volume (4-bed volumes) 0.30mL 0.60mL 1.20mL 3.00mL 3.00mL 6.00mL 12.00mL 30.00mL 60.00mL<br />

Wash Volume (6-bed volumes) 0.45mL 0.90mL 1.80mL 4.50mL 4.50mL 9.00mL 18.00mL 45.00mL 90.00mL<br />

Minimum Elution Volume (3-bed volumes) 0.23mL 0.45mL 0.90mL 2.25mL 2.25mL 4.50mL 9.00mL 22.50mL 45.00mL<br />

*Estimates only. Must optimize for each application.<br />

tech tip<br />

To calculate sorbent bed volume, use 150µL for every 100mg<br />

of sorbent.<br />

tech tip<br />

Retention capacity describes the total amount that an SPE<br />

sorbent will bind. This includes all compounds retained—analytes<br />

of interest as well as the contaminants.<br />

tech tip<br />

Minimum elution volume recommended in bed size chart above<br />

will offer best sensitivity, but more solvent may be required<br />

depending on application.<br />

Solvent Polarity Chart<br />

Less Polar (Stronger Reversed-Phase Elution)<br />

Hexane<br />

Isooctane<br />

Cyclohexane<br />

Carbon tetrachloride<br />

Toluene<br />

Chloroform<br />

Methylene chloride<br />

Tetrahydrofuran<br />

Ethyl ether<br />

Acetone<br />

Acetonitrile<br />

Pyridine<br />

Isopropanol<br />

Ethanol<br />

Methanol<br />

Water<br />

Acetic acid<br />

solid phase extraction<br />

More Polar (Stronger Normal-Phase Elution)<br />

www.discoverysciences.com 297


general chromatography<br />

SPE Introduction<br />

<strong>Grace</strong> Davison ® has been making Davisil ® silica for over a quarter century. It is the<br />

foundation for all our silica-based SPE products, including Alltech ® , Vydac ® , and<br />

<strong>Grace</strong>Pure brands. Having complete control over the entire media process ensures<br />

highly consistent performance, and uninterrupted supply.<br />

Experts in Media Production<br />

Using a consistent and pure silica base, and employing tightly controlled bonding<br />

techniques, insures predictable analyte-sorbent interactions. Both of these aspects<br />

also play equal importance in manufacturing a bonded phase with high and<br />

reproducible recoveries.<br />

Highest Quality Control<br />

Every part of our manufacturing process is carefully monitored. From silica production<br />

to final product, we perform multiple quality tests, and provide a comprehensive<br />

quality assurance certificate.<br />

7377<br />

<strong>Grace</strong> SPE Product Lines<br />

Alltech ® Extract-Clean Columns<br />

Alltech ® Ultra-Clean Columns<br />

solid phase extraction<br />

Format: SPE Columns<br />

Sizes: 1.5, 4, 8, 15, 25, 75mL (the entire tube volume)<br />

Summary: In production for over 25 years, with proven<br />

consistency, this is our most comprehensive SPE<br />

product line. It includes 30 media types in over 10<br />

different bed weights. And with a complete offering<br />

of reversed, normal, and specialty medias exhibiting<br />

unique retention properties, you are sure to find the<br />

packing that delivers a cleaner, more concentrated<br />

sample. See pages 302–306.<br />

Alltech ® Maxi-Clean Cartridges<br />

Format: SPE Cartridges<br />

Sizes: 300, 600, 900mg (media amount, not device<br />

volume)<br />

Summary: The Maxi-Clean line is offered in many<br />

of the same media as the Extract-Clean line, but<br />

slightly paired down, with over 20 chemistries available.<br />

This lure hub cartridge device is not as prevalent in the<br />

SPE industry, and while manual processing is most<br />

common, this format offers a number of other interesting<br />

processing options, including multimedia extractions.<br />

See page 307–310.<br />

Vydac ® Columns<br />

Format: SPE Columns<br />

Sizes: 1, 3mL (volume above the packing)<br />

Summary: Ideal for extraction, concentration and<br />

cleanup of biological samples. This 300Å silica-based<br />

media has the same properties as the industry-leading<br />

Vydac ® TP HPLC packing. Offered in C18 and C4, use<br />

for a variety of protein and peptide applications. See<br />

page 311 for details.<br />

Format: SPE Columns<br />

Sizes: 4, 8mL (the entire tube volume)<br />

Summary: Choose this ultra-low extractable version<br />

for very sensitive applications. Nine selected media are<br />

packed into highly inert fluorinated polypropylene tubes<br />

with PTFE frits. Less expensive than glass extraction<br />

devices, this durable format offers comparable inertness<br />

without the added concern of being easily broken.<br />

See pages 302–305.<br />

Alltech ® 96-Well Plates<br />

Format: 96-Well Plates<br />

Size: 2mL (the individual well volume)<br />

Summary: Ideal for high-throughput SPE processing,<br />

this 8" x 12" standard format fits into traditional 96-well<br />

automated equipment. We offer six different medias<br />

in three bed weights packed in 2mL square wells. See<br />

page 311. Empty plates are also available on page 316.<br />

<strong>Grace</strong>Pure Columns<br />

Format: SPE Columns<br />

Sizes: 1, 3, 6, 12, 20, 60mL (volume above the packing)<br />

Summary: Our in-house capability to make everything<br />

from the silica particle to the finished good means we<br />

can deliver <strong>Grace</strong>Pure as the best value in SPE. With<br />

a concise offering of 11 sorbents in six bed weights, this<br />

high-quality SPE product line is a result of operational<br />

excellence that <strong>Grace</strong> Davison ® is known for. See<br />

pages 312–313.<br />

298<br />

www.discoverysciences.com


general chromatography<br />

SPE Introduction<br />

Device Options<br />

Device Specifications<br />

Device Housing Frit Material<br />

Extract-Clean Columns Polypropylene 20µm Polyethylene<br />

Ultra-Clean Columns Treated 10µm PTFE<br />

Polypropylene<br />

<strong>Grace</strong>Pure Columns Polypropylene 20µm Polyethylene<br />

Vydac ® Columns Polypropylene Glass Fiber Filter Paper with<br />

Polyethylene Mesh Support<br />

Maxi-Clean Cartridges Polypropylene 20µm Polyethylene<br />

96-Well SPE Plates Polypropylene 20µm Polyethylene<br />

SPE Columns<br />

• Open top tubes with male luer bottom<br />

• Process multiple samples with vacuum manifold or automated SPE instruments<br />

• Process individual samples manually with use of adapter and syringe<br />

Traditionally, differing nomenclature has been used to<br />

describe SPE column size. Sometimes columns are<br />

described in terms of full volume. Alternatively, the volume<br />

above the bed weight may also be used. Below is a crossreference<br />

for your convenience.<br />

Alltech ® <strong>Grace</strong>Pure/Vydac ®<br />

1.5mL<br />

1mL<br />

4mL<br />

3mL<br />

8mL<br />

6mL<br />

15mL<br />

12mL<br />

25mL<br />

20mL<br />

75mL<br />

60mL<br />

25mL<br />

7309<br />

15mL<br />

7310<br />

8.0mL<br />

7311<br />

4.0mL<br />

7312<br />

1.5mL<br />

SPE Cartridges<br />

• Female luer top and male luer bottom<br />

• Process single cartridge by syringe<br />

or multiple cartridges by vacuum<br />

• Stack for multi-step extractions<br />

7313<br />

solid phase extraction<br />

SPE 96-Well Plates<br />

• High throughput SPE devices<br />

• 8" x 12" standard 96-well format<br />

• 2mL square wells<br />

7323<br />

7324<br />

300mg Bed<br />

600mg Bed<br />

7308<br />

75mL<br />

4888<br />

7322<br />

900mg Bed<br />

www.discoverysciences.com 299


general chromatography<br />

Alltech ® SPE Sorbents<br />

Alltech ® SPE Sorbents are packed into three device types;<br />

columns, cartridges, and 96-well plates. See chart for availability.<br />

Extract-Clean<br />

SPE Columns<br />

Ultra-Clean<br />

Ultra-low Extractable<br />

SPE Columns<br />

Maxi-Clean<br />

SPE Cartridges<br />

96-Well Plates<br />

High Throughput<br />

SPE Processing<br />

pages 302-306 pages 302-305 pages 307-310 page 311<br />

Reversed-Phases (Non-Polar) Sorbent Specifications<br />

solid phase extraction<br />

%.<br />

Carbon<br />

End-.<br />

capped<br />

Average<br />

Particle<br />

Size<br />

Pore<br />

Size Features Benefits<br />

Packing<br />

Base<br />

Prevail C18 Silica 11.0% Yes 50µm 60Å 100% water wettable Hydrophilic/hydrophobic retention.<br />

Phase remains active even<br />

when completely dry. Can omit<br />

preconditioning step.<br />

x x x<br />

Standard C18 Silica 6.0% Yes 50µm 60Å Low carbon load C18 General purpose phase. x x x x<br />

High-Flow C18 Silica 8.0% Yes 100µm 60Å Large particle Less flow resistance for faster flow x<br />

rates of large volume sample.<br />

High-Capacity C18 Silica 17.0% Yes 50µm 60Å High carbon load Maximum capacity phase. x x<br />

Large Pore C18 Silica 14.0% Yes 50µm 150Å Larger than average pore Ideal for compounds >1500MW. x x<br />

size<br />

Octyl (C8) Silica 4.5% Yes 50µm 60Å Less hydrophobic than C18 Less retention of highly hydrophobic x x x<br />

compounds. Use when C18 is<br />

too retentive.<br />

Ethyl (C2) Silica 5.5% Yes 50µm 60Å Short chain functional group Less retention of highly hydrophobic x x<br />

is less hydrophobic than C8 compounds. Use when C8 is<br />

too retentive.<br />

Phenyl (PH) Silica 3.8% Yes 50µm 60Å Aromatic structure Highly selective for aromatic<br />

compounds.<br />

x x<br />

Normal-Phases (Polar) Sorbent Specifications<br />

Packing<br />

Base<br />

%.<br />

Carbon<br />

End-.<br />

capped<br />

Average<br />

Particle<br />

Size<br />

Pore<br />

Size Features Benefits<br />

Silica (SI) Silica — — 50µm 60Å Highly polar surface Most common polar phase. x x x x<br />

Extract-Clean<br />

Extract-Clean<br />

Ultra-Clean<br />

Ultra-Clean<br />

Maxi-Clean<br />

Maxi-Clean<br />

96-Well<br />

96-Well<br />

Aminopropyl (NH2) Silica 5.0% No 50µm 60Å Polar phase with slight anion<br />

exchange properties<br />

Ideal for carbohydrates or generally<br />

with analyses containing hydroxyl<br />

functional groups.<br />

Cyanopropyl (CN) Silica 6.0% Yes 50µm 60Å Unique selectivity Can be used in normal-phase or<br />

reversed-phase modes.<br />

Diol (2OH) Silica 4.0% No 50µm 60Å Polar surface with minor Wets easily and offers more<br />

hydrophobic retention reproducibility.<br />

Florisil ® (FL)<br />

Magnesium — — 75– 60Å Highly polar surface Referenced in many EPA methods.<br />

Silicate<br />

150µm<br />

Ideally suited for pesticides and<br />

metals.<br />

Florisil ® PR (FL-PR) Magnesium — — 75– 60Å Specifically tested for Ensures most inert batches suitable<br />

Silicate<br />

150µm chlorinated pesticides for highly active compounds.<br />

Alumina Acidic (AL-A) Aluminum — — 130µm 100Å Alumina washed with acid Increase capacity for acidic<br />

Oxide<br />

surface<br />

compounds.<br />

Alumina Basic (AL-B) Aluminum — — 130µm 100Å Alumina washed with base Increase capacity for basic<br />

Oxide<br />

surface<br />

compounds.<br />

Alumina Neutral (AL-N)<br />

Aluminum<br />

Oxide<br />

— — 130µm 100Å Alumina washed with neutral<br />

surface<br />

Interacts with highly aromatic<br />

compounds and neutral hydroxyls.<br />

x x<br />

x x x<br />

x x<br />

x x x<br />

x x x<br />

x x<br />

x x<br />

x x<br />

300<br />

www.discoverysciences.com


general chromatography<br />

Alltech ® Spe Sorbents<br />

Specialty Packings Specifications<br />

%.<br />

Carbon<br />

End-.<br />

capped<br />

Average<br />

Particle<br />

Size<br />

Pore<br />

Size Features Benefits<br />

Packing<br />

Base<br />

DVB 100% DVB — — 40µm — 100% DVB Greater capacity than C18 for<br />

general SPE. Also free vinyl surface<br />

groups make a suitable solid-phase<br />

synthesis support.<br />

Carbograph<br />

Graphitized<br />

Carbon<br />

— — 38–<br />

125µm<br />

Drug-Clean SB-C Silica — — 50µm 60Å Silica-based mixed mode<br />

Drug-Clean SB-A Silica — — 50µm 60Å Silica-based mixed mode<br />

Drug-Clean PB Polymer — — 30µm — Polymer-based mixed mode<br />

C8/cation exchange<br />

AFT<br />

C18, Silica,<br />

and Alumina<br />

6 — 50–<br />

130µm<br />

— Graphitized Carbon Retains polar organics in aqueous<br />

matrices. Ideally suited for acid,<br />

base-neutral extraction of pesticides<br />

and herbicides.<br />

x x<br />

Ideal for drugs of abuse. x x<br />

C8/cation exchange<br />

Ideal for drugs of abuse. x x<br />

C8/anion exchange<br />

— Unique blend of reversed<br />

and normal phases.<br />

pH stable with no conditioning<br />

required. Extract acidic, neutral<br />

and basic drugs of abuse from<br />

single column.<br />

Ideal for Aflatoxins.<br />

Extract-Clean<br />

x<br />

x<br />

x<br />

Ultra-Clean<br />

Maxi-Clean<br />

96-Well<br />

x<br />

General Ion-Exchange Sorbent Specifications<br />

Packing Base Counter Ion<br />

SCX Styrene-<br />

DVB<br />

SAX<br />

Styrene-<br />

DVB<br />

Particle<br />

Size<br />

Functional<br />

Group<br />

Hydrogen 50µm Benzene<br />

Sulfonic<br />

Acid<br />

Acetate 50µm Tetramethyl<br />

Ammonium<br />

Ion Chromatography Sorbent Specifications<br />

Packing Base Counter Ion<br />

IC-OH Styrene-<br />

DVB<br />

IC-H<br />

IC-Ag<br />

IC-Ba<br />

IC-Na<br />

IC-Chelate<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Particle<br />

Size<br />

Molecular<br />

Exclusion<br />

Limit<br />

Hydroxide 50µm 1000<br />

Daltons<br />

Hydronium 50µm 1000<br />

Daltons<br />

Silver 50µm 1000<br />

Daltons<br />

Barium 50µm 1000<br />

Daltons<br />

Sodium 50µm 1000<br />

Daltons<br />

Sodium 50µm 1000<br />

Daltons<br />

Exchange<br />

Capacity Retains Applications<br />

2.0meq/mL<br />

1.0meq/mL<br />

Cations, (+) charged<br />

compounds<br />

Anions, (–) charged<br />

compounds<br />

Exchange<br />

Capacity Retains Applications<br />

IC-RP Polystyrene — 550µm — — Hydrophobic<br />

components<br />

Remove/concentrate basic<br />

compounds.<br />

Remove/concentrate acidic<br />

compounds.<br />

1.0meq/mL Anions Exchanges anions for hydroxide. May be<br />

used to remove or concentrate anions<br />

from sample and to increase pH of acidic<br />

samples. Removes cations that form<br />

insoluble hydroxide salts.<br />

2.0meq/mL Cations Exchanges cations for H + . May be<br />

used to remove or concentrate cations<br />

from sample and to reduce pH of basic<br />

samples.<br />

2.0meq/mL Chloride Iodide Bromide Removes excess halides through<br />

formation of Ag-halide salts.<br />

2.0meq/mL Sulfate Removes excess sulfate through<br />

formation of BaSO.<br />

2.0meq/mL Cations Exchanges cations for Na + . May be used<br />

to remove or retain cations from sample<br />

without changing the pH of the sample.<br />

0.4meq/mL Polyvalent metal ions Exchanges transition metals and divalent<br />

cations for Na + . May be used to remove<br />

or retain divalent cations and transition<br />

metals from sample.<br />

Removes surfactants, organic acids, and<br />

other organic substances. Inorganic ions<br />

pass through.<br />

Extract-Clean<br />

Ultra-Clean<br />

Maxi-Clean<br />

96-Well<br />

x x x x<br />

x x x x<br />

Extract-Clean<br />

Ultra-Clean<br />

Maxi-Clean<br />

96-Well<br />

x x<br />

x x<br />

x x<br />

x x<br />

x x<br />

x x<br />

x x<br />

solid phase extraction<br />

www.discoverysciences.com 301


general chromatography<br />

Alltech ® Extract-Clean and Ultra-Clean Columns<br />

Reversed-Phase Sorbents<br />

4886<br />

Extract-Clean Columns<br />

• Available: Prevail C18, Standard C18,<br />

High-Flow C18, High-Capacity C18,<br />

Octyl (C8), Ethyl (C2), Phenyl (PH)<br />

• General purpose SPE column with the most<br />

comprehensive sorbent offering<br />

Ultra-Clean Columns<br />

• Available: Standard C18, Octyl (C8)<br />

• Low extractable version for highly sensitive<br />

applications—fluorinated polypropylene<br />

columns with PTFE frits<br />

Reversed-Phases (Non-Polar) Sorbent Specifications<br />

%.<br />

Carbon<br />

End-.<br />

capped<br />

Average<br />

Particle<br />

Size<br />

Pore<br />

Size Features Benefits<br />

Functional Group Base<br />

Prevail C18 Silica 11.0% Yes 50µm 60Å 100% water wettable Hydrophilic/hydrophobic retention. Phase<br />

remains active even when completely dry.<br />

Can omit preconditioning step.<br />

Standard C18 Silica 6.0% Yes 50µm 60Å Low carbon load C18 General purpose phase.<br />

High-Flow C18 Silica 8.0% Yes 100µm 60Å Large particle Less flow resistance for faster flow rates<br />

of large volume sample.<br />

High-Capacity C18 Silica 17.0% Yes 50µm 60Å High carbon load Maximum capacity phase.<br />

Large Pore C18 Silica 14.0% Yes 50µm 150Å Larger than average pore size Ideal for compounds >1500MW.<br />

Octyl (C8) Silica 4.5% Yes 50µm 60Å Less hydrophobic than C18 Less retention of highly hydrophobic<br />

compounds. Use when C18 is too<br />

retentive.<br />

Ethyl (C2) Silica 5.5% Yes 50µm 60Å Short chain functional group is less<br />

hydrophobic than C8<br />

Less retention of highly hydrophobic<br />

compounds. Use when C8 is too<br />

retentive.<br />

Phenyl (PH) Silica 3.8% Yes 50µm 60Å Aromatic structure Highly selective for aromatic compounds.<br />

solid phase extraction<br />

Alltech ® Reversed-Phase Extract-Clean Columns<br />

Bed Weight Column Size Qty. Part No.<br />

Prevail C18<br />

100mg 1.5mL 100 605001<br />

130mg 4.0mL 50 605130<br />

500mg 4.0mL 50 605250<br />

500mg 8.0mL 30 605350<br />

1000mg 8.0mL 30 605430<br />

Standard C18<br />

50mg 1.5mL 100 204900<br />

100mg 1.5mL 100 205000<br />

200mg 4.0mL 50 205150<br />

500mg 4.0mL 50 205250<br />

500mg 8.0mL 30 205350<br />

1000mg 8.0mL 30 205430<br />

2000mg 8.0mL 30 205450<br />

2000mg 15mL 30 205462<br />

5000mg 25mL 20 225450<br />

10,000mg 75mL 16 235410<br />

High-Flow C18<br />

500mg 4.0mL 50 215250<br />

1000mg 8.0mL 30 215430<br />

High-Capacity C18<br />

50mg 1.5mL 100 255050<br />

100mg 1.5mL 100 255100<br />

200mg 4.0mL 50 255200<br />

500mg 4.0mL 50 255300<br />

500mg 8.0mL 30 255350<br />

1000mg 8.0mL 30 255430<br />

2000mg 15mL 30 255440<br />

5000mg 25mL 20 255450<br />

10,000mg 75mL 16 255460<br />

Alltech ® Reversed-Phase Extract-Clean Columns (continued)<br />

Bed Weight Column Size Qty. Part No.<br />

Octyl (C8)<br />

100mg 1.5mL 100 206000<br />

200mg 4.0mL 50 206150<br />

500mg 4.0mL 50 206250<br />

500mg 8.0mL 30 206350<br />

Ethyl (C2)<br />

100mg 1.5mL 100 207300<br />

200mg 4.0mL 50 207450<br />

500mg 4.0mL 50 207550<br />

10,000mg 75mL 16 207616<br />

Phenyl (PH)<br />

50mg 1.5mL 100 232062<br />

100mg 1.5mL 100 232000<br />

200mg 4.0mL 50 232150<br />

500mg 4.0mL 50 232300<br />

Alltech ® Reversed-Phase Ultra-Clean SPE Columns<br />

Bed Weight Column Size Qty. Part No.<br />

Standard C18<br />

200mg 4.0mL 50 505150<br />

500mg 8.0mL 30 505355<br />

Octyl (C8)<br />

200mg 4.0mL 50 506151<br />

500mg 4.0mL 50 506251<br />

500mg 8.0mL 30 506351<br />

more info<br />

For SPE Applications, see pages 494–502.<br />

302<br />

www.discoverysciences.com


general chromatography<br />

Alltech ® Extract-Clean and Ultra-Clean Columns<br />

Normal-Phase Sorbents<br />

4886<br />

Extract-Clean Columns<br />

• Available: Silica (SI), Aminopropyl (NH2),<br />

Cyanopropyl (CN), Diol (2OH), Florisil ® (FL),<br />

Florisil ® -PR (FL-PR), Alumina Acidic (AL-A),<br />

Alumina Acidic (AL-B), Alumina Neutral (AL-N)<br />

• General purpose SPE column with the most<br />

comprehensive sorbent offering<br />

Ultra-Clean Columns<br />

• Available: Silica (SI), Aminopropyl (NH2),<br />

Florisil ® (FL), Florisil ® -PR (FL-PR)<br />

• Low extractable version for highly sensitive<br />

applications—fluorinated polypropylene columns with<br />

PTFE frits<br />

Normal-Phases (Polar) Sorbent Specifications<br />

Functional Group Base<br />

%.<br />

Carbon<br />

End-.<br />

capped<br />

Average<br />

Particle<br />

Size<br />

Pore<br />

Size Features Benefits<br />

Silica (SI) Silica — — 50µm 60Å Highly polar surface Most common polar phase.<br />

Aminopropyl (NH2) Silica 5.0% No 50µm 60Å Polar phase with slight anion exchange<br />

properties<br />

Ideal for carbohydrates or generally with<br />

analyses containing hydroxyl functional<br />

groups.<br />

Cyanopropyl (CN) Silica 6.0% Yes 50µm 60Å Unique selectivity Can be used in normal-phase or<br />

reversed-phase modes.<br />

Diol (2OH) Silica 4.0% No 50µm 60Å Polar surface with minor hydrophobic<br />

retention<br />

Florisil ® (FL)<br />

Magnesium<br />

Silicate<br />

— — 75–<br />

150µm<br />

60Å Highly polar surface Referenced in many EPA methods.<br />

Ideally suited for pesticides and metals.<br />

Florisil ® -PR (FL-PR) Magnesium<br />

Silicate<br />

— — 75–<br />

150µm<br />

60Å Specifically tested for chlorinated<br />

pesticides<br />

Ensures most inert batches suitable for<br />

highly active compounds.<br />

Alumina Acidic (AL-A) Aluminum — — 130µm 100Å Alumina washed with acid surface Increase capacity for acidic compounds.<br />

Oxide<br />

Alumina Basic (AL-B) Aluminum<br />

Oxide<br />

— — 130µm 100Å Alumina washed with base surface Increase capacity for basic compounds.<br />

Alumina Neutral (AL-N)<br />

Aluminum<br />

Oxide<br />

— — 130µm 100Å Alumina washed with neutral surface Interacts with highly aromatic compounds<br />

and neutral hydroxyls.<br />

Alltech ® Normal-Phase Extract-Clean Columns<br />

Bed Weight Column Size Qty. Part No.<br />

Silica (SI)<br />

50mg 1.5mL 100 209062<br />

100mg 1.5mL 100 209000<br />

200mg 4.0mL 50 209150<br />

500mg 4.0mL 50 209250<br />

500mg 8.0mL 30 209200<br />

1000mg 8.0mL 30 209100<br />

2000mg 8.0mL 30 209202<br />

2000mg 15mL 30 209362<br />

5000mg 25mL 20 22935<br />

10,000mg 25mL 20 239300<br />

10,000mg 75mL 16 239310<br />

20,000mg 75mL 16 239322<br />

30,000mg 75mL 16 239330<br />

Aminopropyl (NH2)<br />

100mg 1.5mL 100 211000<br />

200mg 4.0mL 50 211025<br />

500mg 4.0mL 50 211150<br />

500mg 8.0mL 30 211256<br />

1000mg 8.0mL 30 211153<br />

Cyanopropyl (CN)<br />

100mg 1.5mL 100 209300<br />

200mg 4.0mL 50 209450<br />

500mg 4.0mL 50 209550<br />

500mg 8.0mL 30 209650<br />

Diol (2OH)<br />

100mg 1.5mL 100 208000<br />

200mg 4.0mL 50 208150<br />

500mg 4.0mL 50 208250<br />

Florisil ® (FL)<br />

100mg 1.5mL 100 204500<br />

500mg 4.0mL 50 204650<br />

1000mg 8.0mL 30 207930<br />

2000mg 15mL 30 207962<br />

Alltech ® Normal-Phase Extract-Clean Columns (continued)<br />

Bed Weight Column Size Qty. Part No.<br />

Florisil ® (FL) (continued)<br />

5000mg 25mL 20 227950<br />

10,000mg 75mL 16 237910<br />

Florisil ® -PR (FL-PR)<br />

500mg 4.0mL 50 250015<br />

1000mg 8.0mL 30 250020<br />

10,000mg 75mL 16 250910<br />

Alumina Acidic (AL-A)<br />

100mg 1.5mL 100 228200<br />

500mg 4.0mL 50 228350<br />

Alumina Basic (AL-B)<br />

100mg 1.5mL 100 228000<br />

500mg 4.0mL 50 228150<br />

Alumina Neutral (AL-N)<br />

100mg 1.5mL 100 228400<br />

500mg 4.0mL 50 228550<br />

2000mg 15mL 30 22856<br />

Alltech ® Normal-Phase Ultra-Clean SPE Columns<br />

Bed Weight Column Size Qty. Part No.<br />

Silica (SI)<br />

200mg 4.0mL 50 509150<br />

500mg 8.0mL 30 509225<br />

5000mg 25mL 20 509010<br />

Aminopropyl (NH2)<br />

200mg 4.0mL 50 511025<br />

500mg 4.0mL 50 511150<br />

Florisil ® (FL)<br />

500mg 4.0mL 50 507851<br />

1000mg 8.0mL 30 507930<br />

Florisil ® -PR (FL-PR)<br />

500mg 4.0mL 50 504651<br />

1000mg 8.0mL 30 507900<br />

solid phase extraction<br />

www.discoverysciences.com 303


general chromatography<br />

Alltech ® Extract-Clean and Ultra-Clean Columns<br />

Ion-Exchange Sorbents<br />

4886<br />

Extract-Clean Columns<br />

• Available: SCX, SAX, IC-OH, IC-H, IC-Ag,<br />

IC-Ba, IC-Na, IC-Chelate, IC-RP<br />

• General purpose SPE column with the most<br />

comprehensive sorbent offering<br />

Ultra-Clean Columns<br />

• Available: SCX, SAX<br />

• Low extractable version for highly sensitive<br />

applications—fluorinated polypropylene<br />

columns with PTFE frits<br />

Ion-Exchange Sorbent Specifications<br />

Packing Base Counter Ion<br />

Particle<br />

Size<br />

SCX Styrene-<br />

DVB<br />

SAX<br />

Styrene-<br />

DVB<br />

Functional<br />

Group<br />

Hydrogen 50µm Benzene<br />

Sulfonic<br />

Acid<br />

Acetate 50µm Tetramethyl<br />

Ammonium<br />

Exchange<br />

Capacity Retains Applications<br />

2.0meq/mL Cations, (+) charged compounds Remove/concentrate basic compounds<br />

1.0meq/mL Anions, (–) charged compounds Remove/concentrate basic compounds<br />

solid phase extraction<br />

Ion Chromatography Sorbent Specifications<br />

Packing Base Counter Ion<br />

IC-OH Styrene-<br />

DVB<br />

IC-H<br />

IC-Ag<br />

IC-Ba<br />

IC-Na<br />

IC-Chelate<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Particle<br />

Size<br />

Molecular<br />

Exclusion<br />

Limit<br />

Hydroxide 50µm 1000<br />

Daltons<br />

Hydronium 50µm 1000<br />

Daltons<br />

Silver 50µm 1000<br />

Daltons<br />

Barium 50µm 1000<br />

Daltons<br />

Sodium 50µm 1000<br />

Daltons<br />

Sodium 50µm 1000<br />

Daltons<br />

Exchange<br />

Capacity Retains Applications<br />

1.0meq/mL Anions Exchanges anions for hydroxide. May be<br />

used to remove or concentrate anions<br />

from sample and to increase pH of acidic<br />

samples. Removes cations that form<br />

insoluble hydroxide salts.<br />

2.0meq/mL Cations Exchanges cations for H + . May be<br />

used to remove or concentrate cations<br />

from sample and to reduce pH of basic<br />

samples.<br />

2.0meq/mL Chloride Iodide Bromide Removes excess halides through<br />

formation of Ag-halide salts.<br />

2.0meq/mL Sulfate Removes excess sulfate through<br />

formation of BaSO.<br />

2.0meq/mL Cations Exchanges cations for Na + . May be used<br />

to remove or retain cations from sample<br />

without changing the pH of the sample.<br />

0.4meq/mL Polyvalent metal ions Exchanges transition metals and divalent<br />

cations for Na + . May be used to remove<br />

or retain divalent cations and transition<br />

metals from sample.<br />

IC-RP Polystyrene — 550µm — — Hydrophobic components Removes surfactants, organic acids, and<br />

other organic substances. Inorganic ions<br />

pass through.<br />

General Ion-Exchange Extract-Clean Columns<br />

Bed Weight Column Size Qty. Part No.<br />

SCX<br />

100mg 1.5mL 100 209800<br />

200mg 4.0mL 50 209825<br />

500mg 4.0mL 50 209950<br />

1000mg 8.0mL 30 209930<br />

SAX<br />

100mg 1.5mL 100 209600<br />

200mg 4.0mL 50 209625<br />

500mg 4.0mL 50 209750<br />

1000mg 8.0mL 30 209850<br />

General Ion-Exchange Ultra-Clean Columns<br />

Bed Weight Column Size Qty. Part No.<br />

SCX<br />

200mg 4.0mL 50 509826<br />

500mg 4.0mL 50 509951<br />

SAX<br />

200mg 4.0mL 50 509626<br />

500mg 4.0mL 50 509751<br />

Ion Chromatography Extract-Clean Columns<br />

Packing Bed Weight Column Size Qty. Part No.<br />

IC-OH 0.5mL 4.0mL 50 40262<br />

IC-OH 1.5mL 4.0mL 30 140254<br />

IC-H 0.5mL 4.0mL 50 40264<br />

IC-H 1.5mL 4.0mL 30 140256<br />

IC-Ag 0.5mL 4.0mL 50 105050<br />

IC-Ag 1.5mL 4.0mL 30 140258<br />

IC-Ba 0.5mL 4.0mL 50 40268<br />

IC-Ba 1.5mL 4.0mL 30 140261<br />

IC-Na 0.5mL 4.0mL 50 40270<br />

IC-Na 1.5mL 4.0mL 30 140263<br />

IC-Chelate 0.5mL 4.0mL 50 40250<br />

IC-Chelate 1.5mL 4.0mL 30 140265<br />

IC-RP 0.5mL 4.0mL 50 40260<br />

IC-RP 1.5mL 4.0mL 30 140252<br />

more info<br />

For SPE Applications, see pages 494–502.<br />

304<br />

www.discoverysciences.com


general chromatography<br />

Alltech ® Extract-Clean and Ultra-Clean Columns<br />

Specialty Sorbents<br />

4886<br />

Extract-Clean Columns<br />

• Available: DVB, Carbograph, AFT, Filter,<br />

Phase Separator, Drying<br />

• General purpose SPE column with the most<br />

comprehensive sorbent offering<br />

Ultra-Clean Columns<br />

• Available: Carbograph<br />

• Low extractable version for highly sensitive<br />

applications—fluorinated polypropylene<br />

columns with PTFE frits<br />

Specialty Packings Specifications<br />

%.<br />

Carbon<br />

End-.<br />

capped<br />

Average<br />

Particle<br />

Size<br />

Pore<br />

Size Features Benefits<br />

Packing<br />

Base<br />

DVB 100% DVB — — 40µm — 100% DVB Greater capacity than C18 for general<br />

SPE. Also free vinyl surface groups make<br />

a suitable solid-phase synthesis support.<br />

Carbograph<br />

AFT<br />

Graphitized<br />

Carbon<br />

C18, Silica,<br />

and Alumina<br />

— — 38–<br />

125µm<br />

6 — 50–<br />

130µm<br />

— Graphitized carbon Retains polar organics in aqueous<br />

matrices. Ideally suited for acid, baseneutral<br />

extraction of pesticides and<br />

herbicides.<br />

Unique blend of reversed and normal Ideal for Aflatoxins.<br />

phases<br />

DVB Extract-Clean Columns<br />

• Greater sample capacity than C18<br />

• 100% divinylbenzene reduces swelling<br />

• 40µm average particle size<br />

DVB Extract-Clean Columns<br />

Bed Weight Column Size Qty. Part No.<br />

25mg 1.5mL 100 220025<br />

50mg 1.5mL 100 220050<br />

100mg 1.5mL 100 220100<br />

500mg 4.0mL 50 220500<br />

Carbograph Extract-Clean Columns<br />

• Graphitized carbon retains polar organics in aqueous<br />

matrices<br />

• Acid, base-neutral extraction of pesticides and herbicides<br />

• 100m 2 /g surface area<br />

Carbograph Extract-Clean Columns<br />

Bed Weight Column Size Qty. Part No.<br />

150mg 4.0mL 50 210142<br />

300mg 8.0mL 30 210101<br />

500mg 8.0mL 30 210150<br />

1000mg 15mL 20 210121<br />

Carbograph Ultra-Clean Columns<br />

Bed Weight Column Size Qty. Part No.<br />

150mg 4.0mL 50 510142<br />

300mg 8.0mL 30 510101<br />

AFT Extract-Clean TM Columns<br />

This blend of C18 and Alumina materials offers unique<br />

selectivity for Mycotoxin removal. AFT Tubes are ideal for<br />

food and beverage analysis.<br />

Phase Separator Extract-Clean TM Columns<br />

Use for fast and simple separation of organic and aqueous<br />

mixed samples. The column contains a 20µm polyethylene<br />

frit and a hydrophobic silicone membrane that allows the<br />

hydrophobic phase to pass through, while the aqueous phase<br />

is retained in the upper chamber.<br />

Phase Separator Extract-Clean TM Columns<br />

Column Size Qty. Part No.<br />

4.0mL 100 205289<br />

8.0mL 100 205389<br />

25mL 100 205589<br />

Filter Columns<br />

Filter columns are Extract-Clean reservoirs with two frits at<br />

the outlet end. They remove particulate matter down to 20µm<br />

from samples. Syringe adapters will connect filter columns to<br />

the tops of Extract-Clean columns.<br />

Extract-Clean Filter Columns<br />

Description Qty. Part No.<br />

1.5mL Filter Columns 100 211101<br />

4.0mL Filter Columns 50 211104<br />

8.0mL Filter Columns 50 211108<br />

75.0mL Filter Columns 50 210775<br />

Drying Tubes<br />

Packed with anhydrous sodium sulfate, use these to remove<br />

residual water from SPE extracts. They are suitable for<br />

pesticide analysis.<br />

Drying Tubes<br />

Bed Weight Qty. Part No.<br />

Extract-Clean Column, 3g 100 219002<br />

solid phase extraction<br />

AFT Extract-Clean TM Columns<br />

Bed Weight Column Size Qty. Part No.<br />

8.0mL 1000mg 100 229101<br />

www.discoverysciences.com 305


general chromatography<br />

Alltech ® Extract-Clean Columns<br />

Specialty Columns<br />

Drug-Clean PB Mixed-Mode SPE Columns<br />

• Polymer based<br />

• Extract acidic, basic, and neutral compounds from<br />

one column<br />

• Stable from pH 1 to 14<br />

• No conditioning steps required<br />

• Faster flow rates than silica-based materials<br />

Drug-Clean PB has a C18/SCX cation function on a highly<br />

cross-linked styrene divinylbenzene base. The high sorbent<br />

capacity greatly reduces the amount of packing required<br />

for separation and makes this material ideal for use in<br />

96-well plates—see page 311.<br />

Each box of columns includes extraction methods for<br />

amphetamines, opiates, cocaine/benzoylecgonine,<br />

phencyclidine, and carboxy-THC.<br />

Drug-Clean SB Mixed-Mode SPE Columns<br />

• Silica based<br />

• Efficient—higher recoveries with minimal impurities<br />

compared to single mode extractions<br />

• Multi-functional—extract acidic, neutral, and basic<br />

compounds with a single SPE bed<br />

• Reproducible—true copolymer is cleaner and more<br />

accurate than mixed beds<br />

Drug-Clean C is a C8/SCX cation function. Retain neutral<br />

or amine containing compounds while carboxylate groups<br />

pass through. Drug-Clean A is a C8/SAX anion function.<br />

Retain neutral or carboxylate compounds while amine group<br />

retention is minimized.<br />

Each box of columns includes extraction methods for the most<br />

popular NIDA drugs of abuse.<br />

Drug-Clean PB Specifications<br />

Functional Group: C18/Cation Function<br />

Base:<br />

30µm Styrene/DVB Polymer<br />

Retention Mechanism: Mixed-mode, reversed-phase, and ion-exchange<br />

Drug-Clean SB Specifications<br />

Functional Group: C8/Ion-Exchange<br />

Base:<br />

50µm irregular silica, 60Å<br />

Retention Mechanism: Mixed-mode, reversed-phase, and ion-exchange<br />

solid phase extraction<br />

Drug-Clean PB SPE Columns<br />

Bed Weight Column Size Qty. Part No.<br />

30mg 1.5mL 100 250120<br />

30mg 4.0mL 50 250130<br />

50mg 8.0mL 50 250140<br />

1<br />

2<br />

Cocaine and Benzoylecgonine<br />

Extract from Urine<br />

4 5 6 7 8 9 10 11 12 13 14 Min.<br />

2656<br />

1. Cocaine (2.5mg/mL)<br />

2. Benzoylecgonine-TMS,<br />

Benzoylecgonine-d3-TMS<br />

(5.0mg/mL)<br />

Drug-Clean SB Columns<br />

Bed Weight Column Size Qty. Part No.<br />

Drug-Clean C (Mixed-Mode Cation) Columns<br />

100mg 1.5mL 100/pk 207015<br />

200mg 4.0mL 50/pk 207010<br />

500mg 4.0mL 50/pk 207017<br />

500mg 8.0mL 30/pk 207019<br />

Drug-Clean A (Mixed-Mode Anion) Columns<br />

100mg 1.5mL 100/pk 207030<br />

200mg 4.0mL 50/pk 207034<br />

Amphetamines Extract from Urine<br />

1<br />

2<br />

2673<br />

1. Amphetamine (2.5 mg/mL)<br />

2. Methamphetamine (2.5 mg/mL)<br />

Column: Heliflex ® AT-5ms, 30m x 0.25mm x 0.25µm<br />

Capillary GC Column (Part No. 15807)<br />

Temp:<br />

225°C (0min hold) to 315°C (11min hold)<br />

at 10°C/min<br />

Carrier Gas: Helium at 0.8mL/min (28cm/sec)<br />

Detector: MSD at 325°C<br />

Sample Prep: Drug-Clean C<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Min.<br />

Column: Heliflex ® AT-35, 30m x 0.25mm x 0.25µm<br />

Capillary GC Column (Part No. 13642)<br />

Temp:<br />

180°C to 300°C at 10°C/min<br />

Carrier Gas: Helium at 0.7mL/min (24cm/sec)<br />

Detector: FID at 275°C<br />

tech tip<br />

Why is a “True Copolymer” better than a mixed bed?<br />

By definition, a mixed-mode packing contains two different functional groups on the same sorbent. To minimize costs, two individual<br />

packings are sometimes blended together physically and packed in a tube. This gives the effect of a mixed-mode but in fact is a<br />

mixed-bed packing with batch-to-batch reproducibility dependent on the blending skills of the manufacturer. A true mixed-mode has the<br />

functional groups polymerized on the same silica base. This copolymer treatment assures a more predictable packing performance<br />

which means more reproducible results from tube to tube, batch to batch.<br />

306<br />

www.discoverysciences.com


general chromatography<br />

Alltech ® Maxi-Clean Cartridges<br />

Save Time and Maximize Sample Preparation Efficiency<br />

Maxi-Clean cartridges have the same bed dimensions as 4mL SPE columns for easy method cross-over. Process a<br />

single cartridge by syringe or multiple cartridges by vacuum. Maxi-Clean cartridges allow you to stack different cartridges for<br />

multi-step extractions. Use top and bottom caps for easy transport of field samples. Here’s 10 different ways these cartridges can<br />

be used to address difficult extractions and SPE protocols.<br />

1. Bulk Preconditioning on a Vacuum.<br />

Manifold<br />

Save time and solvents by<br />

preconditioning Maxi-Clean<br />

Cartridges on a vacuum manifold.<br />

Double stack for even faster<br />

preparation.<br />

6080<br />

6. Easy to Transport and Store<br />

Use top and bottom caps to transport or store<br />

a Maxi-Clean Super Cartridge containing<br />

your analyte, without risking contamination or<br />

dehydration.<br />

6086<br />

2. Direct Substitution into Methods Using .<br />

Standard 4mL Columns<br />

Maxi-Clean Cartridges have the<br />

same bed dimensions as traditional<br />

4mL SPE columns, for easy<br />

substitution into established protocols.<br />

6085<br />

7. Process Individually or in Parallel<br />

Do you only have a few samples<br />

to process? Process them with<br />

a syringe, instead of setting up<br />

a vacuum manifold. Do you have<br />

a lot of samples to process? Add<br />

an empty reservoir to process them<br />

simultaneously on your manifold.<br />

3. Stack Two Cartridges in Series .<br />

for Complex Separations<br />

6087<br />

Maxi-Clean Cartridges can be stacked<br />

to combine two phases into one extraction<br />

step for complex analyses. You can even<br />

elute each phase individually, if desired.<br />

4. Elute Anywhere<br />

Use a syringe to elute your<br />

analyte anywhere—directly<br />

into an injection valve, or into<br />

other receiver vessels. You can<br />

even attach a needle and elute<br />

directly through a septa or 96-well sealing mat.<br />

5. Combine SPE with Filtration by Adding a .<br />

Filter Tube or Syringe Filter in Series<br />

6082<br />

6083<br />

8. Use In-line<br />

The Maxi-Clean cartridge’s luer connections<br />

allow you to use them in-line, to remove<br />

contaminants or act as a “guard” cartridge<br />

in low-pressure applications.<br />

9. Custom-fit to Your Sample Size<br />

By changing reservoir sizes, you<br />

can customize a Maxi-Clean<br />

Cartridge to fit your sample<br />

size without changing the bed<br />

dimensions.<br />

6091<br />

6088<br />

solid phase extraction<br />

The Maxi-Clean Cartridge’s luer<br />

connections allow you to add a syringe filter<br />

or a fritted SPE tube to remove particulates<br />

before your sample enters the SPE bed.<br />

10. Choose from 23 Chemistries<br />

6089<br />

The Maxi-Clean line is offered<br />

in many of the same media as<br />

the Extract-Clean line, but<br />

slightly paired down, with over<br />

20 chemistries available.<br />

6091<br />

6084<br />

6090<br />

www.discoverysciences.com 307


general chromatography<br />

Alltech ® Maxi-Clean Cartridges<br />

Reversed-Phase Cartridges<br />

• Same bed dimensions as 4mL SPE columns for<br />

method cross-over<br />

• Process a single cartridge by syringe or multiple<br />

cartridges by vacuum<br />

• Stack different cartridges for multi-step extractions<br />

4881<br />

• Use top and bottom caps for easy transport of<br />

field samples 4915<br />

Reversed-Phases (Non-Polar) Sorbent Specifications<br />

%.<br />

Carbon<br />

End-.<br />

capped<br />

Average<br />

Particle<br />

Size<br />

Pore<br />

Size Features Benefits<br />

Packing<br />

Base<br />

Prevail C18 Silica 11.0% Yes 50µm 60Å 100% water wettable Hydrophilic/hydrophobic retention. Phase<br />

remains active even when completely dry.<br />

Can omit preconditioning step.<br />

Standard C18 Silica 6.0% Yes 50µm 60Å Low carbon load C18 General purpose phase.<br />

High-Flow C18 Silica 8.0% Yes 100µm 60Å Large particle Less flow resistance for faster flow rates<br />

of large volume sample.<br />

High-Capacity C18 Silica 17.0% Yes 50µm 60Å High carbon load Maximum capacity phase.<br />

Large Pore C18 Silica 14.0% Yes 50µm 150Å Larger than average pore size Ideal for compounds >1500MW.<br />

Octyl (C8) Silica 4.5% Yes 50µm 60Å Less hydrophobic than C18 Less retention of highly hydrophobic<br />

compounds. Use when C18 is too<br />

retentive.<br />

Ethyl (C2) Silica 5.5% Yes 50µm 60Å Short chain functional group is less<br />

hydrophobic than C8<br />

Less retention of highly hydrophobic<br />

compounds. Use when C8 is too<br />

retentive.<br />

Phenyl (PH) Silica 3.8% Yes 50µm 60Å Aromatic structure Highly selective for aromatic compounds.<br />

solid phase extraction<br />

Maxi-Clean Reversed-Phase Cartridges<br />

Packing Bed Weight Qty. Part No.<br />

Prevail C18 300mg 50 605926<br />

500mg 50 605929<br />

900mg 50 605942<br />

Standard C18 300mg 25 20924<br />

300mg 50 20926<br />

300mg 100 20928<br />

600mg 25 20932<br />

600mg 50 20934<br />

600mg 100 20936<br />

900mg 25 20940<br />

900mg 50 20942<br />

900mg 100 20944<br />

High-Capacity C18 300mg 50 20945<br />

Large Pore C18 300mg 100 22012<br />

600mg 100 22017<br />

900mg 100 220215<br />

Octyl (C8) 300mg 50 20950<br />

600mg 50 20958<br />

900mg 50 20966<br />

Ethyl (C2) 300mg 50 210064<br />

Phenyl (PH) 300mg 25 22002<br />

300mg 50 22003<br />

300mg 100 22004<br />

tech tip<br />

What is a Maxi-Clean cartridge?<br />

A Maxi-Clean cartridge is an alternative format for SPE. It uses<br />

the same high-quality packing materials as the Extract-Clean<br />

columns but has a polypropylene housing with both a female<br />

luer inlet and a male luer outlet tip. This allows use of positive<br />

pressure from a syringe or negative pressure from a vacuum<br />

manifold. 20µm polyethylene frits are placed at each end of the<br />

sorbent bed. The packing material is packed and compressed to<br />

improve or optimize flow characteristics.<br />

4870<br />

more info<br />

For SPE Applications, see pages 494–502.<br />

related products<br />

Looking for vacuum manifolds?<br />

See pages 314–315 for vacuum<br />

manifolds to process samples.<br />

Maxi-Clean Drying Cartridges<br />

Packing Bed Weight Qty. Part No.<br />

Sodium Sulfate 3g 100 219001<br />

308<br />

www.discoverysciences.com


general chromatography<br />

Alltech ® Maxi-Clean Cartridges<br />

Normal-Phase Cartridges<br />

• Same bed dimensions as 4mL SPE columns for<br />

method cross-over<br />

• Process a single cartridge by syringe or multiple<br />

cartridges by vacuum<br />

• Stack different cartridges for multi-step extractions<br />

4881<br />

• Use top and bottom caps for easy transport of<br />

field samples 4915<br />

Normal-Phases (Polar) Sorbent Specifications<br />

Packing<br />

Base<br />

%.<br />

Carbon<br />

End-.<br />

capped<br />

Average<br />

Particle<br />

Size<br />

Pore<br />

Size Features Benefits<br />

Silica (SI) Silica — — 50µm 60Å Highly polar surface Most common polar phase.<br />

Aminopropyl (NH2) Silica 5.0% No 50µm 60Å Polar phase with slight anion exchange<br />

properties<br />

Ideal for carbohydrates or generally with<br />

analyses containing hydroxyl functional<br />

groups.<br />

Cyanopropyl (CN) Silica 6.0% Yes 50µm 60Å Unique selectivity Can be used in normal-phase or<br />

reversed-phase modes.<br />

Diol (2OH) Silica 4.0% No 50µm 60Å Polar surface with minor hydrophobic<br />

retention<br />

Wets easily and offers more<br />

reproducibility.<br />

Florisil ® (FL)<br />

Magnesium<br />

Silicate<br />

— — 75–<br />

150µm<br />

60Å Highly polar surface Referenced in many EPA methods.<br />

Ideally suited for pesticides and metals.<br />

Florisil ® -PR (FL-PR) Magnesium<br />

Silicate<br />

— — 75–<br />

150µm<br />

60Å Specifically tested for chlorinated<br />

pesticides<br />

Ensures most inert batches suitable for<br />

highly active compounds.<br />

Alumina Acidic (AL-A) Aluminum — — 130µm 100Å Alumina washed with acid surface Increase capacity for acidic compounds.<br />

Oxide<br />

Alumina Basic (AL-B) Aluminum<br />

Oxide<br />

— — 130µm 100Å Alumina washed with base surface Increase capacity for basic compounds.<br />

Alumina Neutral (AL-N)<br />

Aluminum<br />

Oxide<br />

— — 130µm 100Å Alumina washed with neutral surface Interacts with highly aromatic compounds<br />

and neutral hydroxyls.<br />

Maxi-Clean Normal-Phase Cartridges<br />

Packing Bed Weight Qty. Part No.<br />

Silica (SI) 300mg 25 20972<br />

300mg 50 20974<br />

300mg 100 20976<br />

600mg 25 20980<br />

600mg 50 20982<br />

600mg 100 20984<br />

900mg 25 20988<br />

900mg 50 20990<br />

900mg 100 20992<br />

Aminopropyl (NH2) 300mg 50 210044<br />

300mg 100 210046<br />

900mg 100 210047<br />

Cyanopropyl (CN) 300mg 50 210034<br />

300mg 100 210036<br />

Diol (2OH) 300mg 50 210084<br />

300mg 100 210086<br />

Florisil ® (FL) 300mg 50 210054<br />

300mg 100 210056<br />

900mg 50 210057<br />

900mg 100 210061<br />

Florisil ® -PR (FL-PR) 300mg 50 210074<br />

300mg 100 210076<br />

900mg 50 210079<br />

900mg 100 210075<br />

Alumina Acidic (AL-A) 300mg 25 210094<br />

1800mg 25 210097<br />

Alumina Basic (AL-B) 300mg 25 210093<br />

1800mg 25 210096<br />

Alumina Neutral (AL-N) 300mg 25 210095<br />

1800mg 25 210098<br />

related products<br />

Looking for standard .<br />

luer-hub syringes to<br />

process Maxi-Clean<br />

cartridges?<br />

See page 347.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

4675<br />

solid phase extraction<br />

www.discoverysciences.com 309


general chromatography<br />

Alltech ® Maxi-Clean Cartridges<br />

Ion-Exchange Cartridges<br />

• Eliminate matrix interferences before ion analysis<br />

• Seven chemistries solve a variety of specific problems<br />

The most difficult part of many IC applications is eliminating interfering<br />

components from the sample matrix. These interferences may co-elute or mask<br />

peaks of interest, overload the column, or shorten the column life by binding<br />

irreversibly to the column packing. The Alltech ® unique ion-exchange SPE<br />

cartridge eliminates many of these interferences 1,2 .<br />

Each metal-free polypropylene cartridge contains 0.5mL or 1.5mL of purified polystyrene resin, contained by<br />

20µm polyethylene frits. The resin is functionalized to retain specific types of components from the sample.<br />

1<br />

R. Saari-Nordhaus, J.M. Anderson, Jr., and I.K. Henderson, Am. Lab. August (1990) 19.<br />

2<br />

I.K. Henderson, R. Saari-Nordhaus, and J.M. Anderson, Jr., J. Chromatogr. 546 (1991) 61.<br />

4893<br />

Ion-Exchange Sorbent Specifications<br />

Packing Base Counter Ion<br />

Particle<br />

Size<br />

SCX Styrene-<br />

DVB<br />

SAX<br />

Styrene-<br />

DVB<br />

Functional<br />

Group<br />

Hydrogen 50µm Benzene<br />

Sulfonic<br />

Acid<br />

Acetate 50µm Tetramethyl<br />

Ammonium<br />

Exchange<br />

Capacity Retains Applications<br />

2.0meq/mL Cations, (+) charged compounds Remove/concentrate basic compounds.<br />

1.0meq/mL Anions, (–) charged compounds Remove/concentrate basic compounds.<br />

solid phase extraction<br />

Ion Chromatography Sorbent Specifications<br />

Packing Base Counter Ion<br />

IC-OH Styrene-<br />

DVB<br />

IC-H<br />

IC-Ag<br />

IC-Ba<br />

IC-Na<br />

IC-Chelate<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Styrene-<br />

DVB<br />

Particle<br />

Size<br />

Molecular<br />

Exclusion<br />

Limit<br />

Hydroxide 50µm 1000<br />

Daltons<br />

Hydronium 50µm 1000<br />

Daltons<br />

Silver 50µm 1000<br />

Daltons<br />

Barium 50µm 1000<br />

Daltons<br />

Sodium 50µm 1000<br />

Daltons<br />

Sodium 50µm 1000<br />

Daltons<br />

Exchange<br />

Capacity Retains Applications<br />

1.0meq/mL Anions Exchanges anions for hydroxide. May be<br />

used to remove or concentrate anions<br />

from sample and to increase pH of acidic<br />

samples. Removes cations that form<br />

insoluble hydroxide salts.<br />

2.0meq/mL Cations Exchanges cations for H + . May be<br />

used to remove or concentrate cations<br />

from sample and to reduce pH of basic<br />

samples.<br />

2.0meq/mL Chloride Iodide Bromide Removes excess halides through<br />

formation of Ag-halide salts.<br />

2.0meq/mL Sulfate Removes excess sulfate through<br />

formation of BaSO.<br />

2.0meq/mL Cations Exchanges cations for Na + . May be used<br />

to remove or retain cations from sample<br />

without changing the pH of the sample.<br />

0.4meq/mL Polyvalent metal ions Exchanges transition metals and divalent<br />

cations for Na + . May be used to remove<br />

or retain divalent cations and transition<br />

metals from sample.<br />

IC-RP Polystyrene — 550µm — — Hydrophobic components Removes surfactants, organic acids, and<br />

other organic substances. Inorganic ions<br />

pass through.<br />

General Ion-Exchange Maxi-Clean Cartridges<br />

Packing Bed Weight Qty. Part No.<br />

SCX 600mg 25 21901<br />

600mg 50 21902<br />

600mg 100 21903<br />

SAX 600mg 25 21906<br />

600mg 50 21907<br />

600mg 100 21908<br />

Ion Chromatography Maxi-Clean Cartridges<br />

Packing Bed Weight Qty. Part No.<br />

IC-OH 0.5mL 50 30262<br />

IC-OH 1.5mL 25 30254<br />

IC-H 0.5mL 50 30264<br />

IC-H 1.5mL 25 30256<br />

IC-Ag 0.5mL 50 30266<br />

IC-Ag 1.5mL 25 30258<br />

IC-Ba 0.5mL 50 30268<br />

IC-Ba 1.5mL 25 30261<br />

IC-Na 0.5mL 50 30270<br />

IC-Na 1.5mL 25 30263<br />

IC-Chelate 0.5mL 50 30250<br />

IC-Chelate 1.5mL 25 30265<br />

IC-RP 0.5mL 50 30260<br />

IC-RP 1.5mL 25 30252<br />

Mixed-Mode RP-OH 0.5mL 25 30259<br />

Mixed-Mode RP-H 0.5mL 25 30267<br />

310<br />

www.discoverysciences.com


general chromatography<br />

Alltech ® 96-Well Plates<br />

• High-throughput SPE devices<br />

• Standard 96-Well format<br />

• Square 2mL wells<br />

Prevail C18 96-Well Plates<br />

Bed Weight Well Volume Qty. Part No.<br />

25mg 2.0mL 1 8619193<br />

50mg 2.0mL 1 8619192<br />

100mg 2.0mL 1 8619191<br />

4888<br />

SAX 96-Well Plates<br />

Bed Weight Well Volume Qty. Part No.<br />

25mg 2.0mL 1 219696<br />

50mg 2.0mL 1 209696<br />

100mg 2.0mL 1 229696<br />

Standard C18 96-Well Plates<br />

Bed Weight Well Volume Qty. Part No.<br />

25mg 2.0mL 1 214996<br />

50mg 2.0mL 1 204996<br />

100mg 2.0mL 1 224996<br />

Silica 96-Well Plates<br />

Bed Weight Well Volume Qty. Part No.<br />

25mg 2.0mL 1 219096<br />

50mg 2.0mL 1 209096<br />

100mg 2.0mL 1 229096<br />

SCX 96-Well Plates<br />

Bed Weight Well Volume Qty. Part No.<br />

25mg 2.0mL 1 219896<br />

50mg 2.0mL 1 209896<br />

100mg 2.0mL 1 229896<br />

Drug-Clean 96-Well Plate<br />

Bed Weight Qty. Part No.<br />

30mg per Well ea 250150<br />

related products<br />

Looking for empty .<br />

96-Well plates?<br />

Refer to page 316.<br />

Vydac ® SPE Columns<br />

For Extraction, Concentration and Clean-up of Biological Samples<br />

Vydac ® SPE columns are disposible sample clean-up<br />

devices which complement <strong>Grace</strong> Vydac ® HPLC columns.<br />

The media are the same high-quality silica bonded with the<br />

same chemistries used in Vydac ® 300Å TP reversed-phase<br />

HPLC columns, giving Vydac ® SPE columns similar selectivity<br />

and recovery.<br />

Applications for Vydac ® SPE columns:<br />

• Desalting of polypeptide solutions<br />

• Concentration of proteins and peptides<br />

• Removal of HF and cleavage products from cleavage<br />

solutions<br />

• Removal of lipids and strongly bound proteins<br />

• Improvement of HPLC resolution by prior removal of<br />

early and late eluting by-products or reagents<br />

• Preparation of environmental and food samples<br />

Vydac ® SPE Columns<br />

Column Size Pkg. Part No.<br />

C4, 13µm 1 mL 50 214SPE1000<br />

3 mL 50 214SPE3000<br />

C18, 13µm 1 mL 50 218SPE1000<br />

3 mL 50 218SPE3000<br />

Solid-Phase Extraction Example<br />

Column:<br />

Gradient:<br />

A. 5% ACN<br />

B. 30% ACN<br />

ribonuclease<br />

C. 60% ACN<br />

myoglobin<br />

0 10 Min.<br />

Vydac ® 214TP5405, C4, 5µm, 4.6 x 50mm<br />

15 to 70% ACN over 10min, with 0.1% TFA<br />

A 3mL SPE column was conditioned with 1mL of ACN followed by<br />

1mL of 5% ACN/0.1% TFA. Ribonuclease and myglobin (100mg each)<br />

were then loaded in 30% ACN/0.1% TFA. The column was washed with<br />

1mL of 5% ACN/0.1% TFA to remove weakly bound compounds, then<br />

1mL of 30% ACN/0.1% TFA followed by 1mL of 60% ACN/0.1% TFA.<br />

HPLC analysis of the 5% ACN wash (A) revealed only a small amount<br />

of ribonuclease. Most of the ribonuclease eluted in the 30% ACN wash<br />

(B). The myoglobin eluted almost entirely in the 60% ACN wash (C).<br />

solid phase extraction<br />

www.discoverysciences.com 311


general chromatography<br />

<strong>Grace</strong>Pure SPE Sorbent Specifications<br />

• Ideal for cost-conscious labs<br />

• Concise offering of popular sorbents<br />

new<br />

<strong>Grace</strong>Pure SPE products have a concise offering of sorbents suitable for<br />

a variety of applications. Whether pharmaceutical or petrochemical, these products<br />

deliver the selectivity and high recovery you expect. Use this guide to help you choose<br />

the appropriate sorbent, bed size, and solvent volumes to ensure you have a cleaner, more<br />

concentrated sample at the end of your SPE process.<br />

Reversed-Phase (Non-Polar) Sorbents Specifications<br />

%<br />

Carbon<br />

Surface.<br />

Area<br />

Particle.<br />

Size<br />

Sorbent Support<br />

Endcapping<br />

C18-Max Silica 17.1% Yes 518m 2 /g 50µm 60Å Polymerically bonded<br />

17% carbon load<br />

Pore.<br />

Size Feature Benefit Application Type<br />

Highest binding capacity,<br />

best for complex samples or<br />

structurally diverse analytes.<br />

C18-Aq Silica 12.5% Yes 518m 2 /g 50µm 60Å Hydrophilic endcapping Water-wettable C18 ideal for<br />

aqueous samples. Phase<br />

remains active even when<br />

completely dry.<br />

C18-Low Silica 6.5% Yes 518m 2 /g 50µm 60Å Least hydrophobic C18 phase that easily releases<br />

C18 phase<br />

very hydrophobic compounds.<br />

C18-Fast Silica 7.0% Yes 518m 2 /g 100µm 60Å Large 100µm particle Process large volume (>500mL)<br />

or viscous samples with fast<br />

flow rates.<br />

TMS Silica 5.6% No 518m 2 /g 50µm 60Å Low carbon load<br />

trimethyl silane phase<br />

Least hydrophobic reversedphase<br />

elutes non-polar<br />

compounds easily. Short carbon<br />

chain has little steric hindrance<br />

to uniformly cover silica surface.<br />

Drugs and their metabolites in<br />

serum and plasma, pesticides<br />

Desalting proteins,<br />

pharmaceuticals, hormones,<br />

pesticides, organics in water<br />

Surfactants, oils, antibiotics<br />

Aniline, pesticides, haloethers,<br />

phthalate esters, EPA 3620,<br />

3610<br />

Oils, dyes, surfactants<br />

solid phase extraction<br />

Normal-Phase (Polar) Sorbents Specifications<br />

Sorbent Support<br />

%<br />

Carbon Endcapping<br />

Surface<br />

Area<br />

Particle<br />

Size<br />

Pore<br />

Size Feature Benefit Application Type<br />

Silica Silica N/A N/A 518m 2 /g 50µm 60Å Most polar phase Able to differentiate between<br />

structurally similar compounds.<br />

Aflatoxins, pesticides,<br />

steroids, structural isomers<br />

Amino Silica 4.3% No 518m 2 /g 50µm 60Å Dual retention Retains polar compounds,<br />

or can act as a weak anion<br />

exchanger. Easily releases<br />

strong acids when SAX binds<br />

too strongly.<br />

Diol Silica N/A No 518m 2 /g 50µm 60Å Reproducible polar<br />

bonded phase<br />

Florisil ®<br />

Magnesium<br />

Silicate<br />

N/A No 120µm 60Å Alternates polar<br />

phase<br />

Very polar phase that has the<br />

same benefits as silica, but<br />

wets easily and offers more<br />

reproducibility.<br />

Large particle size processes<br />

large sample sizes quickly.<br />

Carbohydrates, dyes, lipids,<br />

mycotoxins, strong acids<br />

Alkaloids, lipids, oils, structural<br />

isomers<br />

Environmental<br />

Ion-Exchange Sorbents Specifications<br />

Exchange<br />

Sorbent Support<br />

Capacity Counter Ion<br />

Anion-X 8% cross-linked<br />

styrenedivinylbenzene<br />

Cation-X<br />

8% cross-linked<br />

styrenedivinylbenzene<br />

Particle<br />

Size Feature Benefit Application Type<br />

1.5meq/g Acetate form 50µm Tetramethyl ammonium<br />

functional group on<br />

polymer base material<br />

2.4meq/g Hydrogen form 50µm Benzene sulfonic acid<br />

functional group on<br />

polymer base material<br />

pH range from 1–14, with<br />

excellent exchange capacity.<br />

pH range from 1–14, with<br />

excellent exchange capacity.<br />

Anionic compounds: organic<br />

acids, fatty acids<br />

Cationic compounds: amines,<br />

amino acids<br />

312<br />

www.discoverysciences.com


general chromatography<br />

<strong>Grace</strong>Pure SPE Columns<br />

new<br />

Quality Assurance Certificate<br />

Base Material Properties<br />

<strong>Grace</strong>Pure base silicas are characterized multiple<br />

ways to ensure that the starting point for every batch<br />

of media is consistent. Parameters that can directly affect<br />

SPE results are shown for lot-to-lot comparison.<br />

Sorbent Characterization<br />

Tight specifications promise clean and reproducible sorbent<br />

performance. An HPLC chromatogram offers a detailed look<br />

at selectivity that is not possible with recovery tests alone.<br />

Turbidity measurements after sorbent bonding confirm that<br />

fines were not created during the manufacturing process.<br />

Component Tests<br />

GC/FID shows that <strong>Grace</strong>Pure tubes are constructed from<br />

a highly inert grade of polypropylene to prevent extractable<br />

contamination. Polyethylene frits are thoroughly washed in<br />

organic solvent which also eliminates extractables.<br />

Manufacturing Control<br />

<strong>Grace</strong>Pure SPE products are packed and assembled using<br />

custom-designed, precision equipment. Every manufacturing<br />

batch is guaranteed to have less than 2% bed weight variation<br />

and uniform flow rates. A sophisticated visual inspection<br />

system only accepts product that meets our high standards<br />

for bed consistency and frit integrity.<br />

<strong>Grace</strong>Pure Reversed-Phase SPE Columns<br />

Sorbent Bed Weight Column Volume Qty. Part No.<br />

C18-Max 50mg 1mL 100pk 5141484<br />

100mg 1mL 100pk 5138765<br />

500mg 3mL 50pk 5138766<br />

500mg 6mL 30pk 5138767<br />

1000mg 6mL 30pk 5138768<br />

2000mg 20mL 20pk 5141525<br />

5000mg 20mL 20pk 5141524<br />

C18-Aq 50mg 1mL 100pk 5141486<br />

100mg 1mL 100pk 5138774<br />

500mg 3mL 50pk 5138775<br />

1000mg 6mL 30pk 5138776<br />

2000mg 12mL 30pk 5141482<br />

5000mg 20mL 20pk 5141523<br />

5000mg 20mL 30pk 5141489<br />

C18-Low 100mg 1mL 100pk 5138760<br />

200mg 3mL 50pk 5138761<br />

500mg 3mL 50pk 5138762<br />

500mg 6mL 30pk 5138763<br />

1000mg 6mL 30pk 5138764<br />

5000mg 20mL 20pk 5141526<br />

C18-Fast 500mg 3mL 50pk 5138758<br />

1000mg 6mL 30pk 5138759<br />

5000mg 20mL 20pk 5141527<br />

TMS 50mg 1mL 100pk 5141485<br />

100mg 1mL 100pk 5138785<br />

500mg 3mL 50pk 5138786<br />

<strong>Grace</strong>Pure Normal-Phase SPE Columns<br />

Sorbent Bed Weight Column Volume Qty. Part No.<br />

Silica 100mg 1mL 100pk 5138777<br />

200mg 3mL 50pk 5138778<br />

500mg 3mL 50pk 5138779<br />

5000mg 20mL 20pk 5138780<br />

500mg 6mL 30pk 5138781<br />

1000mg 6mL 30pk 5138782<br />

2000mg 12mL 30pk 5138783<br />

10000mg 60mL 16pk 5138784<br />

Amino 500mg 3mL 50pk 5138752<br />

1000mg 6mL 30pk 5138753<br />

Diol 100mg 1mL 100pk 5138771<br />

200mg 3mL 50pk 5138772<br />

500mg 3mL 50pk 5138773<br />

Florisil ® 500mg 3mL 50pk 5141522<br />

1000mg 6mL 30pk 5141520<br />

2000mg 12mL 30pk 5141521<br />

<strong>Grace</strong>Pure Ion-Exchange SPE Columns<br />

Sorbent Bed Weight Column Volume Qty. Part No.<br />

Anion-X 100mg 1mL 100pk 5138754<br />

500mg 3mL 50pk 5138755<br />

1000mg 3mL 50pk 5141487<br />

Cation-X 100mg 1mL 100pk 5138769<br />

500mg 3mL 50pk 5138770<br />

1000mg 3mL 50pk 5141488<br />

solid phase extraction<br />

more info<br />

For SPE Applications, see pages 494–502.<br />

www.discoverysciences.com 313


general chromatography<br />

SPE Tube<br />

Vacuum Manifolds<br />

• 12-, 16-, and 24-port manifolds<br />

• Glass chamber for visual<br />

monitoring<br />

• Accepts standard male luer<br />

devices<br />

I<br />

C<br />

Vacuum Manifold Components<br />

A. Glass Chamber<br />

B. Vacuum Valve and Gauge<br />

C. Polypropylene Lid<br />

D. Stopcock Valves<br />

E. Collection Rack Plates<br />

F. Support Posts for Collection Racks<br />

G. Retaining Clips for Collection Racks<br />

H. Lid Legs<br />

I. Manifold Inlet Caps<br />

J. Polypropylene Needles<br />

Vacuum manifolds process multiple<br />

samples simultaneously, saving<br />

time and effort. Manifold systems<br />

come complete with the components<br />

listed below. Stainless steel or PTFE<br />

needles are available separately.<br />

A<br />

E<br />

F<br />

H<br />

B<br />

E<br />

J<br />

I<br />

G<br />

D<br />

6278<br />

12-Port Manifold<br />

• For up to 12 samples<br />

• Also includes one waste<br />

container<br />

24-Port Manifold<br />

• Process up to 24 samples<br />

4871<br />

solid phase extraction<br />

12-Port Manifold and Accessories<br />

Description Qty. Part No.<br />

12-Port Vacuum Manifold** ea 210351<br />

Replacement Parts<br />

Lid, Gaskets, and 12 Stopcocks ea 212001<br />

Glass Chamber ea 213212<br />

Vacuum Gauge, Valve, and Glass Chamber ea 212304<br />

Collection Rack, 12-Port Size* ea 212518<br />

Gaskets, 12-Port Size 2 212112<br />

One-Way Stopcocks 12 213112<br />

Waste Container 2 210033<br />

*12-Port Collection Rack includes 3 support posts, bottom plate, 13- and 16mm plates,<br />

autosampler vial plate, volumetric plate, and 12 retaining clips.<br />

**Includes waste container.<br />

96-Well Plate<br />

Vacuum Manifold<br />

4869<br />

24-Port Manifold and Accessories<br />

Description Qty. Part No.<br />

24-Port Vacuum Manifold ea 210224<br />

Replacement Parts<br />

Lid, Gaskets, and 24 Stopcocks ea 211224<br />

Glass Chamber ea 210124<br />

Vacuum Gauge, Valve, and Glass Chamber ea 210324<br />

Collection Rack, 24-Port Size † ea 210424<br />

Gaskets, 16- and 24-Port Size 2 210724<br />

One-Way Stopcocks 24 211524<br />

†<br />

16- and 24-Port Collection Racks include 3 support posts, bottom plate, dimple plate,<br />

13- and 16mm plates, and 12 retaining clips.<br />

Process standard 2mL 96 Deep Well Plates via vacuum<br />

source. Collect directly into a microplate. Also accommodates<br />

48 4mL SPE columns or 24 6mL SPE columns with<br />

appropriate plate adapters.<br />

96-Well Plate Vacuum Manifold<br />

Description Qty. Part No.<br />

96-Well Plate Vacuum Manifold ea 8619194<br />

7435<br />

314<br />

www.discoverysciences.com


general chromatography<br />

Manifold Accessories<br />

Replacement Parts for All Size Manifolds<br />

Manifolds come complete with all necessary gauges and<br />

accessories. Individual replacement parts may be sold<br />

separately.<br />

Drying Attachments<br />

Use these special drying lids to direct a gas flow into<br />

collection tubes to dry eluents. Barb is 1/4".<br />

B<br />

F<br />

G<br />

D<br />

E<br />

A<br />

C<br />

5951<br />

4878<br />

Replacement Parts for All Size Manifolds<br />

Description Qty. Part No.<br />

A. Vacuum Gauge and Valve ea 212203<br />

B. Retaining Clips for Collections Racks 12 212912<br />

C. Female Luer Inlet 2 212002<br />

Female Luer Inlet 24/pk 212302<br />

D. Male Luer Outlet 2 212120<br />

Male Luer Outlet 24/pk 212320<br />

E. Caps for Lid Inlets 50 211234<br />

F. Lid Legs, Black 4 410510<br />

G. Collection Rack Posts 3 410410<br />

Tygon ® Tubing<br />

Tygon ® vacuum tubing is heavy walled and flexible.<br />

It withstands 29.9" Hg at 75°F (24°C). It is nontoxic,<br />

nonoxidizing, and transparent.<br />

Drying Attachments<br />

Description Qty. Part No.<br />

12-Port Drying Attachment 1 212100<br />

16-Port Drying Attachment 1 212117<br />

24-Port Drying Attachment 1 212124<br />

Manifold Needles<br />

PTFE needles are disposable, fit many different manifold<br />

types, and eliminate cross contamination by extending into<br />

the collection tube. They also provide a complete PTFE fluid<br />

path for samples to virtually eliminate extractables. Stainless<br />

steel and polypropylene needles are also available.<br />

Stainless Steel<br />

PTFE<br />

Polypropylene<br />

solid phase extraction<br />

Valved PTFE<br />

4874<br />

Tygon ® Vacuum Tubing<br />

Description Qty. Part No.<br />

1/8" i.d., 3/8" o.d. 50' 6465<br />

3/16" i.d., 9/16" o.d. 10' 6467<br />

1/4" i.d., 3/4" o.d. 10' 6469<br />

3/8" i.d., 7/8" o.d.* 10' 6472<br />

*Use with Vacuum Gauge and Valve displayed above.<br />

3849<br />

Manifold Needles<br />

Description Qty. Part No.<br />

PTFE Needles 100 412410<br />

PTFE Needles 500 412450<br />

Valved PTFE Needles 25 411525<br />

Valved PTFE Needles 50 411550<br />

Stainless Steel Needles 12 212400<br />

Stainless Steel Needles 16 210816<br />

Stainless Steel Needles 24 210824<br />

Polypropylene Needles 12 212412<br />

Polypropylene Needles 16 210916<br />

Polypropylene Needles 24 210924<br />

www.discoverysciences.com 315


general chromatography<br />

Reservoirs and Frits<br />

Select empty reservoirs and loose frits to pack your own<br />

custom SPE columns.<br />

Adapters and Caps<br />

• Inlet caps fit SPE devices as indicated<br />

• Outlet caps fit any column or cartridge with a male luer tip<br />

5952<br />

solid phase extraction<br />

Bulk Reservoirs and Frits<br />

Description Qty. Part No.<br />

Extract-Clean Empty Reservoirs, Polypropylene<br />

1.5mL 100 210001<br />

4.0mL 100 210104<br />

8.0mL 100 210208<br />

15.0mL 100 210315<br />

25.0mL 100 210425<br />

75.0mL 50 210575<br />

Ultra-Clean Empty Reservoirs, Treated Polypropylene<br />

4.0mL 100 70216<br />

8.0mL 100 70218<br />

8.0mL 1000 70069<br />

Polyethylene Frits for Extract-Clean Reservoirs<br />

For 1.5mL Reservoir 100 211401<br />

For 4.0mL or EV Reservoir 100 211404<br />

For 8.0mL Reservoir 100 211408<br />

For 15.0mL Reservoir 100 211412<br />

For 25.0mL Reservoir 100 211416<br />

For 75.0mL Reservoir 100 211775<br />

PTFE Frits for Ultra-Clean Reservoirs<br />

For 4.0mL Reservoir 100 211494<br />

For 8.0mL Reservoir 100 211498<br />

Empty 96-Well Plates<br />

• Square, 2mL wells<br />

• All-polypropylene construction<br />

• Use to pack your own custom<br />

SPE plates<br />

6288<br />

Standard 96-well plate<br />

footprint (8x12 wells)<br />

96-Well Plates<br />

Bed Weight Qty. Part No.<br />

Empty plate with bottom frit installed,<br />

top frit supplied<br />

1 210780<br />

4888<br />

Caps<br />

Description Qty. Part No.<br />

Inlet Caps for Maxi-Clean Cartridges 50 211015<br />

Inlet Caps for 1.5mL 50 220000<br />

Inlet Caps for 4.0mL 50 220301<br />

Inlet Caps for 8.0mL 50 220600<br />

Inlet Caps for 15.0mL 50 221200<br />

Inlet Caps for 25.0mL 50 221006<br />

Inlet Caps for 75.0mL 50 227503<br />

Outlet Caps for Male Luers 50 220710<br />

Syringe Adapters fit the tops of SPE columns allowing<br />

attachment of any male luer device. This lets you process<br />

an Extract-Clean column with a syringe or add an empty<br />

reservoir to increase sample volume capacity.<br />

Syringe Adapters<br />

Description Qty. Part No.<br />

Syringe Adapters for 1.5, 4.0, and 8.0mL<br />

15 210705<br />

Columns<br />

Syringe Adapters for 25mL Columns 5 210707<br />

Syringe Adapters for 75mL Columns 5 210709<br />

Bulk SPE Packings<br />

The same high-quality material we use to<br />

manufacture our Extract-Clean and<br />

Maxi-Clean SPE products.<br />

Bulk SPE Packings<br />

Description Qty. Part No.<br />

Reversed-Phase Adsorbents<br />

Prevail C18 (11%) 100g 211505<br />

C18 (6%) 100g 211502<br />

C18 (17%) 100g 211503<br />

Large Pore C18 (14%) 100g 211542<br />

C8 100g 211504<br />

C2 100g 211506<br />

Phenyl 100g 211522<br />

Normal-Phase Adsorbents<br />

Silica 100g 211512<br />

Aminopropyl 100g 211516<br />

Diol 100g 211518<br />

Florisil ® 227g 5618<br />

Florisil ® -PR 227g 5615<br />

Alumina-N 100g 211541<br />

Ion-Exchange<br />

SCX (Cation Exchange) 100g 211520<br />

SAX (Anion Exchange) 100g 211510<br />

Carbograph 1 SPE 120/400 Mesh 25g 1769<br />

4900<br />

316<br />

www.discoverysciences.com


general chromatography<br />

Filtration Introduction<br />

Filter Membrane Chemical Compatibility<br />

C = Compatible<br />

L = Limited Compatibility<br />

N = Not Compatible<br />

– = No Data Available<br />

Filter Membrane Chemical Compatibility Chart<br />

Filter Membrane Chemical Compatibility Chart<br />

Chemical<br />

Acids<br />

Acetic, 25% L C C C<br />

Acetic, Glacial L C C C<br />

Formic, 25% N C C C<br />

Hydrochloric, 25% L C C C<br />

Hydrochloric, Concentrated N N C C<br />

Sulfuric, 25% N C C C<br />

Sulfuric, Concentrated N C L L<br />

Nitric, 25% N C L C<br />

Nitric, Concentrated N C L N<br />

Phosphoric, 25% N C C C<br />

Trichloroacetic, 10% L C C C<br />

Bases<br />

Ammonium Hydroxide, 25% C C L —<br />

Sodium Hydroxide, 3 Normal C C C —<br />

Alcohols<br />

Amyl Alcohol C C C C<br />

Benzyl Alcohol C C C C<br />

Butyl Alcohol C C C C<br />

Ethanol, 70% C C C C<br />

Ethanol, 98% C C C C<br />

Ethylene Glycol C C C C<br />

Glycerine (Glycerol) C C C C<br />

Isopropanol C C C C<br />

Methanol, 98% C C C C<br />

n-Propanol C C C C<br />

Propylene Glycol C C C C<br />

Hydrocarbons<br />

Benzene C C C C<br />

Hexane, Xylene C C C C<br />

Kerosene, Gasoline C C C C<br />

Tetralin, Decalin C C C —<br />

Toluene C C C C<br />

Halogenated Hydrocarbons<br />

Carbon Tetrachloride C C C C<br />

Chlorobenzene (Mono) C C C C<br />

Chloroform L C C C<br />

Freon C C C C<br />

Methylene Chloride L C C C<br />

Trichloroethane C C C C<br />

Trichloroethylene C C C C<br />

Nylon<br />

PTFE<br />

PVDF<br />

Regenerated Cellulose<br />

Chemical<br />

Ketones<br />

Acetone C C N C<br />

Cyclohexanone C C N C<br />

Isopropylacetone C C N —<br />

Methyl Ethyl Ketone C C L C<br />

Methyl Isobutyl Ketone (MIBK) C C N C<br />

Esters<br />

2-Ethoxyethyl Acetate L L L C<br />

Amyl Acetate C C C C<br />

Benzyl Benzoate C C — C<br />

Butyl Acetate C C C C<br />

Ethyl Acetate C C C C<br />

Isopropyl Myristate C C — C<br />

Methyl Acetate L C L C<br />

Propyl Acetate L N C C<br />

Propylene Glycol Acetate L C — C<br />

Methyl Cellosolve Acetate C C C C<br />

Tricresyl Phosphate — C — C<br />

Oxides — Ethers<br />

Acetonitrile (Methyl Cyanide) C C C C<br />

Aniline L C C C<br />

Diethyl Acetamide C C C C<br />

Dimethyl Formamide C C N L<br />

Dimethyl Sulfoxide (DMSO) L C C L<br />

Dioxane C C L L<br />

Ethyl Ether C C C C<br />

Isopropyl Ether C C N —<br />

Pyridine C C L C<br />

Solvents with Nitrogen<br />

Tetrahydrofuran C C L L<br />

Triethanolamine C C C C<br />

Miscellaneous<br />

Formaldehyde Solution, 30% C C C L<br />

Hydrogen Peroxide, 30% N C C C<br />

Phenol, Aqueous, 10% N C L C<br />

Silicone Oil and Mineral Oil C C C C<br />

more info<br />

This is only a guide. Users should verify compatibility under actual<br />

use conditions.<br />

Nylon<br />

PTFE<br />

PVDF<br />

Regenerated Cellulose<br />

filtration<br />

www.discoverysciences.com 317


general chromatography<br />

Filtration Introduction<br />

Filter Device Selection<br />

Consider the number of samples, the sample volume, and<br />

the filtering mechanism you prefer to use.<br />

Syringe Filters<br />

Filtration is achieved by pushing the sample through the<br />

membrane with a syringe or other luer-connection device.<br />

Syringe filters allow you to control the rate of flow, which can<br />

be critical with delicate samples. Syringe filters also allow you<br />

to filter into nearly any tube, vial, or column that represents<br />

the next step in your analysis.<br />

Centrifuge Filter Tubes<br />

Filtration is achieved by pulling the sample through the<br />

membrane with centrifugal force. This allows you to<br />

simultaneously filter as many samples as your centrifuge<br />

can hold, and captures your filtrate in a clean microtube.<br />

6277<br />

Pre-Cut Membranes<br />

Multiple diameters offer a wide range of sample capacities,<br />

up to multiple liters. You need a filtration apparatus, such as<br />

a filter funnel or other vacuum-driven filtration device.<br />

Device Capacities<br />

Description<br />

Sample Volume<br />

Syringe Filter Capacities<br />

4mm Syringe Filter<br />

≤1mL<br />

13mm Syringe Filter<br />

≤5mL<br />

17mm Syringe Filter<br />

≤50mL<br />

25mm Syringe Filter<br />

≤50mL<br />

30mm Syringe Filter<br />

≤100mL<br />

Centrifuge Filter Tube Capacities<br />

2mL Tubes 20µL to 500µL<br />

50mL Tubes<br />

1mL to 25mL<br />

Pre-Cut Membrane Capacities<br />

13mm Pre-Cut Membranes<br />

up to 20mL<br />

25mm Pre-Cut Membranes<br />

up to 100mL<br />

47mm Pre-Cut Membranes<br />

multi-liter<br />

Membrane Selection<br />

filtration<br />

Choose a filter membrane based on the size and amount of particulate in the sample, the membrane’s chemical compatibility<br />

with the sample matrix, and potential interactions (binding) between the membrane and the sample components. This table offers<br />

general guidelines on membrane characteristics and applications.<br />

Membrane Selection Guide<br />

Membrane Type Features Common Uses Hydrophilic<br />

Solvent<br />

Resistance<br />

Protein<br />

Binding<br />

Nylon<br />

Good chemical compatibility and very General filtration<br />

Yes Good Medium<br />

low extractables<br />

sterilization, HPLC sample prep<br />

Polytetrafluoroethylene<br />

Compatible with strong acids and<br />

Gas, air, and solvent filtration No High* High<br />

(PTFE)<br />

aggressive solvents<br />

Polyvinylidene Fluoride<br />

Good flow rate characteristics.<br />

HPLC sample preparation and Yes High Low<br />

(PVDF)<br />

Ideal for chromatography applications. general filtration<br />

Regenerated Cellulose<br />

Yes High Very Low**<br />

*Highest solvent resistance.<br />

**Lowest protein binding.<br />

Universal membrane with excellent<br />

chemical resistance and low extractables.<br />

Use for aqueous and organic samples.<br />

HPLC sample prep<br />

general filtration<br />

related products<br />

Looking for mobile.<br />

inlet phase filters?<br />

See pages 123–124.<br />

6265<br />

5564<br />

318<br />

www.discoverysciences.com


general chromatography<br />

Syringe Filters<br />

Nylon and PVDF Syringe Filters<br />

Nylon and PVDF syringe filters are available in a variety of<br />

diameters to address different sample sizes.<br />

Syringe Filter Specifications<br />

Diameter Max. Temp. Max. Pressure Hold-Up Volume<br />

Typical Sample<br />

Volume<br />

4mm 100°C 75psig Less than 15µL Up to 1mL<br />

13mm 60°C 100psig Less than 10µL Up to 5mL<br />

17mm 100°C 115psig Less than 25µL Up to 50mL<br />

25mm 60°C 100psig Less than 50µL Up to 50mL<br />

30mm 100°C 90psig Less than 115µL Up to 100mL<br />

6735<br />

Choose Nylon Membranes for General Filtration<br />

Needs<br />

Nylon is hydrophilic and has generally good solvent<br />

resistance.<br />

Choose PVDF Membranes for HPLC Sample<br />

Preparation<br />

PVDF is hydrophilic, highly solvent resistant, and low protein<br />

binding.<br />

Nylon Syringe Filters<br />

Diameter Pore Size Qty. Part No.<br />

4mm 0.2µm 100 2091<br />

4mm 0.45µm 100 2092<br />

13mm 0.2µm 100 2166<br />

13mm 0.45µm 100 2167<br />

17mm 0.2µm 100 62163<br />

17mm 0.45µm 100 62177<br />

25mm 0.2µm 100 2045<br />

25mm 0.45µm 100 2047<br />

30mm 0.2µm 100 62145<br />

30mm 0.45µm 100 62147<br />

PVDF Syringe Filters<br />

Diameter Pore Size Qty. Part No.<br />

4mm 0.2µm 100 2227<br />

4mm 0.45µm 100 2228<br />

13mm 0.2µm 100 2647<br />

13mm 0.45µm 100 2648<br />

17mm 0.2µm 100 62130<br />

17mm 0.45µm 100 62209<br />

25mm 0.2µm 100 2223<br />

25mm 0.45µm 100 2224<br />

30mm 0.2µm 100 62193<br />

30mm 0.45µm 100 62195<br />

related products<br />

Looking for HPLC column<br />

prefilters?<br />

See page 111.<br />

related products<br />

Need vials?<br />

We offer a full selection of<br />

vials, caps, and septa for<br />

all chromotography needs.<br />

See pages 348–378.<br />

filtration<br />

related products<br />

Need syringes?<br />

See pages 336–347 for<br />

our offering of high-quality<br />

Hamilton ® , VICI ® , and<br />

SGE ® syringes.<br />

www.discoverysciences.com 319


general chromatography<br />

Syringe Filters<br />

PTFE and Regenerated Cellulose Syringe<br />

Filters<br />

PTFE and Regenerated Cellulose syringe filters are available<br />

in a variety of diameters to address different sample sizes.<br />

Syringe Filter Specifications<br />

Diameter Max. Temp. Max. Pressure Hold-Up Volume<br />

Typical Sample<br />

Volume<br />

4mm 100°C 75psig Less than 15µL Up to 1mL<br />

13mm 60°C 100psig Less than 10µL Up to 5mL<br />

17mm 100°C 115psig Less than 25µL Up to 50mL<br />

25mm 60°C 100psig Less than 50µL Up to 50mL<br />

30mm 100°C 90psig Less than 115µL Up to 100mL<br />

Choose PTFE Membranes for Aggressive .<br />

Filtration Needs Such as Gas and .<br />

Solvent Filtration<br />

PTFE is hydrophobic with exceptional solvent resistance.<br />

PTFE Syringe Filters<br />

Diameter Pore Size Qty. Part No.<br />

4mm 0.2µm 100 2394<br />

4mm 0.45µm 100 2395<br />

13mm 0.2µm 100 2164<br />

13mm 0.45µm 100 2165<br />

17mm 0.2µm 100 62118<br />

17mm 0.45µm 100 62136<br />

25mm 0.2µm 100 2089<br />

25mm 0.45µm 100 2090<br />

30mm 0.2µm 100 62189<br />

30mm 0.45µm 100 62191<br />

Choose Regenerated Cellulose Membranes<br />

for HPLC Sample Preparation and General<br />

Filtration Needs<br />

Regenerated Cellulose is hydrophilic with exceptional solvent<br />

resistance and very low protein binding.<br />

Regenerated Cellulose Syringe Filters<br />

Diameter Pore Size Qty. Part No.<br />

4mm 0.2µm 100 656100<br />

4mm 0.45µm 100 656102<br />

17mm 0.2µm 100 62119<br />

17mm 0.45µm 100 62125<br />

30mm 0.2µm 100 62199<br />

30mm 0.45µm 100 62167<br />

filtration<br />

related products<br />

Need syringes?<br />

See pages 336–347 for<br />

our offering of high-quality<br />

Hamilton ® , VICI ® , and<br />

SGE ® syringes.<br />

related products<br />

Accessories for your system. <strong>Grace</strong><br />

has an assortment of Accessories<br />

Quick Reference guides available for<br />

many popular instruments.<br />

• Waters ® Alliance ®<br />

System Accessories<br />

– Request M202<br />

• Agilent 1100 and 1200<br />

System Accessories<br />

– Request M203<br />

• Waters ® Acquity ®<br />

System Accessories<br />

– Request M204<br />

320<br />

www.discoverysciences.com


general chromatography<br />

2mL Centrifuge Filter Tubes<br />

• For up to 850µL sample volume<br />

• Economical alternative to brand name filter tubes<br />

• Includes a glass support membrane<br />

Quickly and easily remove particulates and clarify small<br />

sample volumes. Less than 5µL hold-up volume provides<br />

near quantitative volumetric recovery. Maximum G-Force:<br />

10,000xG.<br />

50mL Centrifuge Filter Tubes<br />

• For up to 25mL sample volume<br />

• Use with fixed-angle rotor centrifuge<br />

• All tubes include a glass support membrane<br />

Alltech ® 50mL Centrifuge Filter Tubes remove particulates<br />

from larger sample sizes with any centrifuge that holds<br />

50mL conical tubes. They should only be used with a<br />

fixed-angle rotor centrifuge to prevent premature clogging<br />

of the membrane. Maximum operating temperature: 50°C.<br />

Maximum G-force: 2500xG.<br />

Alltech ® 2mL Filter Tubes<br />

Membrane Type, Pore Size Qty. Part No.<br />

Cellulose Acetate<br />

0.20µm 100 24126<br />

0.45µm 100 24133<br />

Nylon<br />

0.20µm 100 24137<br />

0.45µm 100 24139<br />

PVDF (Hydrophobic)<br />

0.20µm 100 24142<br />

0.45µm 100 24144<br />

Regenerated Cellulose<br />

0.20µm 100 24148<br />

0.45µm 100 24150<br />

4817<br />

Alltech ® 50mL Filter Tubes<br />

Membrane Type, Pore Size Qty. Part No.<br />

Cellulose Acetate<br />

0.20µm 50 24152<br />

0.45µm 50 24154<br />

Nylon<br />

0.20µm 50 24156<br />

0.45µm 50 24158<br />

PVDF (Hydrophobic)<br />

0.20µm 50 24160<br />

0.45µm 50 24162<br />

4784<br />

Forensic Spin Tubes<br />

• 600µL capacity<br />

• Extract biological fluids from cloth samples<br />

The 1.4mm mesh filter basket acts as a sieve to retain cloth<br />

samples and pass fluids to the receiver tube. The spin tube<br />

includes a 600µL filter basket and a 2mL microcentrifuge<br />

receiver tube with attached cap.<br />

Forensic Spin Tubes<br />

Description Qty. Part No.<br />

Forensic Spin 100 2566<br />

Forensic Spin 250 2567<br />

4818<br />

filtration<br />

www.discoverysciences.com<br />

321


general chromatography<br />

Pre-Cut Filter Membranes<br />

• Variety of pore sizes and membrane types<br />

• Non-sterile<br />

Cellulose Acetate Pre-Cut Membranes<br />

Diameter Pore Size Qty. Part No.<br />

13mm 0.20µm 100 2125<br />

13mm 0.45µm 100 2126<br />

25mm 0.20µm 100 2128<br />

25mm 0.45µm 100 2129<br />

47mm 0.20µm 100 2133<br />

47mm 0.45µm 100 2135<br />

Nylon Pre-Cut Membranes<br />

Diameter Pore Size Qty. Part No.<br />

13mm 0.20µm 100 2046<br />

13mm 0.45µm 100 2044<br />

25mm 0.20µm 100 2050<br />

25mm 0.45µm 100 2048<br />

47mm 0.20µm 100 2034<br />

47mm 0.45µm 100 2024<br />

4777<br />

Cellulose Acetate Membranes<br />

Cellulose Acetate Membranes are hydrophilic and exhibit<br />

very low protein retention. Use for general biological filtration,<br />

sterilization, and filtration of aqueous solutions.<br />

Nylon Membranes<br />

Nylon Membranes are hydrophilic and resistant to many<br />

solvents. Use for filtration and clarification of aqueous or<br />

organic solutions.<br />

PTFE Membranes<br />

PTFE Membranes are hydrophobic and highly solvent<br />

resistant. Use for filtration of air, gases, and non-aqueous<br />

solutions. Pre-treat with methanol before using with<br />

aqueous solutions.<br />

PTFE Pre-Cut Membranes<br />

Diameter Pore Size Qty. Part No.<br />

13mm 0.20µm 100 2013<br />

13mm 0.45µm 100 2015<br />

25mm 0.20µm 100 2023<br />

25mm 0.45µm 100 2029<br />

25mm 1.00µm 100 2056<br />

47mm 0.20µm 100 2057<br />

47mm 0.45µm 100 2058<br />

47mm 1.00µm 100 2059<br />

4777<br />

more info<br />

Need help selecting the correct<br />

membrane?<br />

See pages 317–318 for membrane<br />

specifications and suggested<br />

use/applications.<br />

filtration<br />

related product<br />

Looking for solvent filtration<br />

apparatus?<br />

See page 127.<br />

6266<br />

322 www.discoverysciences.com


general chromatography<br />

Recommended Reagents for GC Derivatization<br />

Chemically Modify Your Sample to Improve the Chromatography<br />

Recommended Reagents for GC Derivatization<br />

Compound Type of Derivative ECD* Possible Reagent Choices<br />

Alcohols Acetate Acetic Anhydride/Pyridine<br />

TMS<br />

Sil-Prep, BSTFA/TMCS<br />

t-Butyl Dimethyl Silyl Ether<br />

t-Butyl-DMCS/Imidazole, MTBSTFA<br />

Aldehydes Dimethyl Acetal DMF/DMA<br />

Amines TMS Sil-Prep<br />

Acetate<br />

Pyridine-Plus<br />

Amine (Primary and Secondary) Acetate Acetic Anhydride/Pyridine<br />

TMS<br />

MSHFBA<br />

Amino Acids TMS BSTFA<br />

HFB-Isobutyl Ester<br />

HFB-IBA Kit<br />

Trifluoroacetate X Trifluoroacetic Anhydride<br />

Bile Acids Acetate Pyridine-Plus<br />

Carbohydrates Acetate Acetic Anhydride/Pyridine<br />

TMS<br />

Power Sil-Prep<br />

Catecholamines Trifluorocetate X N-(Trifluoroacetyl)imidazole<br />

Drugs:<br />

Alkaloids Heptafluorobutyrate X Heptafluorobutyric Anhydride<br />

TMS<br />

MSTFA, Sil-Prep<br />

Antibiotics TMS Sil-Prep, Power Sil-Prep<br />

Anticonvulsants TMS MSTFA, BSA/TMCS<br />

Barbiturates N-Methyl Barb-Prep<br />

Dimethyl Ketal<br />

DMF/DMA<br />

Cannabinoids Trifluoroacetate X N-(Trifluoroacetyl)imidazole<br />

TMS<br />

BSTFA, MSTFA<br />

Estrogens Acetate Pyridine-Plus<br />

Fatty Acids:<br />

C9 and Longer Methyl Ester Methanolic HCl, Meth-Prep I<br />

Short Chain (Up to C8) TMS MSTFA<br />

Methyl Ester<br />

Methanolic HCl, Meth-Prep I<br />

Glycerides (mono and di) Acetate Acetic Anhydride/Pyridine<br />

Glycerides (mono, di, and tri) Methyl Ester Sodium Methoxide/Methanol, Meth-Prep II<br />

Glycolipids, Sphingolipids Methyl Ester Sodium Methoxide/Methanol, Meth-Prep II<br />

Hydroxyamines TMS BSTFA<br />

Hydroxy Groups (Primary/Secondary) Heptafluorobutyrate X Heptafluorobutylimidazole<br />

Trifluoroacetate X N-(Trifluoroacetyl)imidazole<br />

17-Ketosteroids TMS DMF-Sil-Prep<br />

Phenols Heptafluorobutyrate X Heptafluorobutyric Anhydride<br />

TMS<br />

BSTFA<br />

Methyl Esters<br />

DMF/DMA<br />

Polyols TMS Sil-Prep, Power Sil-Prep<br />

Steroids TMS Sil-Prep<br />

Acetate<br />

Pyridine-Plus<br />

Trifluoroacetate X Trifluoroacetic Anhydride<br />

*Derivatives suitable for use with Electron Capture Detector (ECD).<br />

tech tip<br />

When do you use derivatization?<br />

When you need to:<br />

1. Increase or decrease the volatility of the analytes to improve separation<br />

2. Improve peak symmetry by reducing interaction of sample and column<br />

3. Increase detector response (i.e., ECD)<br />

4. Enhance thermal stability<br />

standards and reagents<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

www.discoverysciences.com<br />

323


general chromatography<br />

Ready-To-Use Silylation Mixes<br />

Silylation replaces an active hydrogen atom (-OH, -NH2,<br />

-NHR, -SH) with a silyl group. Generally, it reduces the<br />

polarity of the compound and decreases possibility of<br />

hydrogen bonding.<br />

t-Butyldimethylchlorosilyl/Imidazole Reagents<br />

• Derivatives of alcohols are more stable than TMS ethers<br />

to hydrolysis<br />

t-Butyldimethylchlorosilyl/Imidazole<br />

Description Qty. Part No.<br />

t-BuDMCS/Imidazole 10 x 1mL 18028<br />

POWER Sil-Prep (TMSIM:BSA:TMCS) Reagents<br />

• Powerful reagent for sterically hindered groups<br />

POWER Sil-Prep<br />

Description Qty. Part No.<br />

POWER Sil-Prep 10 x 1mL 18012<br />

DMF Sil-Prep (HMDS:TMCS:DMF) Reagents<br />

• Prevents enolization of keto groups<br />

5421<br />

DMF Sil-Prep<br />

Description Qty. Part No.<br />

DMF Sil-Prep 10 x 1mL 18015<br />

Sil-Prep (HMDS:TMCS:pyridine) Reagents<br />

• General purpose reagent for making TMS derivatives<br />

Sil-Prep<br />

Description Qty. Part No.<br />

Sil-Prep 10 x 1mL 18013<br />

standards and reagents<br />

tech tip<br />

Silylation Reagent Strength<br />

HMDS<br />

TMCS<br />

Sil-Prep<br />

MSTFA<br />

MSHFBA<br />

BSA<br />

BSTFA<br />

TMSIM<br />

BSTFA +1% TMCS<br />

POWER Sil-Prep<br />

tech tip<br />

What are the requirements for a good reagent?<br />

It will:<br />

1. Not cause any rearrangements or structural changes in<br />

the analyte<br />

2. Produce a reaction that is 95–100% complete<br />

3. Produce a stable derivative<br />

4. Not contribute to loss of sample during the reaction<br />

5. Produce a derivative that is inert to the column and connections<br />

6. Not produce interfering byproducts<br />

related product<br />

Looking for a Safe and Easy<br />

Way to Open Ampules?<br />

Try the Ampule Cracker.<br />

See page 380.<br />

4958<br />

324 www.discoverysciences.com


general chromatography<br />

Individual Silylation Reagents<br />

BSA [N,O-bis(trimethylsilyl)acetamide]<br />

• Powerful silylating reagent and solvent for polar<br />

compounds<br />

BSA<br />

Description Qty. Part No.<br />

BSA 10mL 18056<br />

BSA 25mL 18057<br />

BSA 10 x 1mL 18034<br />

BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide)<br />

• More volatile reagent and byproducts compared to BSA<br />

• Powerful silylating reagent; even more effective combined<br />

with TMCS as a catalyst<br />

BSTFA<br />

Description Qty. Part No.<br />

BSTFA 10mL 18085<br />

BSTFA 10 x 1mL 18040<br />

BSTFA + 1% TMCS 10mL 18087<br />

BSTFA + 1% TMCS 10 x 1mL 18089<br />

CMDMCS<br />

• Longer retention times than TMCS derivatives<br />

• Enhanced ECD response<br />

CMDMCS<br />

Description Qty. Part No.<br />

CMDMCS 5mL 18031<br />

MSTFA<br />

(N-Methyl-N-trimethylsilyltrifluoroacetamide)<br />

• Ideal reagent for drug analysis because excess reagent<br />

and byproducts elute during solvent delay<br />

• May be used directly on HCl salts of compounds<br />

MSTFA<br />

Description Qty. Part No.<br />

MSTFA 10mL 18061<br />

MSTFA 1 x 1mL 18038<br />

MTBSTFA [N-(tert-butyldimethylsilyl)-<br />

N-methyltrifluoroacetamide]<br />

• Derivatives more stable than common TMS derivatives<br />

• Produces a distinct M-57 ion in GC/MS analysis<br />

• Even more effective when combined with TBDMCS as<br />

a catalyst<br />

MTBSTFA<br />

Description Qty. Part No.<br />

MTBSTFA 10 x 1mL 18097<br />

MTBSTFA 10mL 18102<br />

MTBSTFA + 1% TBDMCS 10 x 1mL 18155<br />

MTBSTFA + 1% TBDMCS 10mL 18148<br />

TMCS (Trimethylchlorosilane)<br />

• Similar to HMDS when used alone<br />

• Very effective as a catalyst to other reagents<br />

DMCS (Dimethylchlorosilane)<br />

• DMS derivatives are more sensitive to hydrolysis than<br />

TMS derivatives<br />

DMCS<br />

Description Qty. Part No.<br />

DMCS 3 x 10mL 18071<br />

HMDS (Hexamethyldisilazane)<br />

• Slow and inefficient used alone<br />

• Very effective in combination with TMCS<br />

TMCS<br />

Description Qty. Part No.<br />

TMCS 3 x 10mL 18091<br />

TMCS 10 x 1mL 18084<br />

TMSIM (N-Trimethylsilylimidazole)<br />

• Preferentially silylates hydroxyl groups<br />

• Best silylation reagent when water is present<br />

TMSIM<br />

Description Qty. Part No.<br />

TMSIM 10 x 1mL 18050<br />

standards and reagents<br />

HMDS<br />

Description Qty. Part No.<br />

HMDS 25mL 18069<br />

HMDS 10 x 1mL 18003<br />

MSHFBA (N-Methyl-<br />

N-trimethylsilylheptafluorobutyramide)<br />

• Similar to MSTFA but does not produce harmful deposits<br />

in FID<br />

MSHFBA<br />

Description Qty. Part No.<br />

MSHFBA 10mL 214610<br />

MSHFBA 20 x 1mL 2146201<br />

Glass Conditioning Reagent<br />

Glass-Prep (5% DMDCS in toluene)<br />

• Deactivate any glass surface<br />

Glass-Prep<br />

Description Qty. Part No.<br />

Glass-Prep 100mL 9700<br />

Glass-Prep 400mL 2233<br />

DMDCS, Neat 10 x 5mL 18090<br />

www.discoverysciences.com<br />

325


general chromatography<br />

Alkylation (Esterification)<br />

Reagents<br />

Alkylation replaces an acidic hydrogen (carboxylic acids,<br />

phenols) with an alkyl group. Alkyl esters are extremely stable<br />

and can be stored for long periods of time.<br />

Meth-Prep I<br />

• On-column derivatization<br />

• Aqueous solution does not give solvent peak<br />

Meth-Prep I is a 0.2N aqueous solution of<br />

(m-trifluoromethylphenyl) trimethylammonium hydroxide.<br />

When the reagent is mixed with fatty acids and then<br />

injected into a GC injector at 240ºC, the methyl esters<br />

are formed along with the by-product, m-trifluoromethylphenyl<br />

dimethylamine. The reaction is clean, fast, and quantitative.<br />

Meth-Prep I, being in aqueous solution, does not give a<br />

solvent peak. This may be advantageous in some cases.<br />

Meth-Prep I<br />

Description Qty. Part No.<br />

Meth-Prep I 10 x 1mL 18005<br />

Transesterification Reagents<br />

Transesterification is the process of converting one type of<br />

ester into another. Most commonly this is a very large ester<br />

(i.e., triglycerides, steryl esters, wax esters, phospholipids)<br />

converted into a methyl ester that is more easily analyzed.<br />

Meth-Prep II<br />

• In one step forms fatty acid methyl esters from<br />

triglycerides at room temperature<br />

• Requires no extraction before injecting into GC<br />

• Faster than sodium methoxide reagents<br />

Meth-Prep II is a 0.2N methanolic solution of<br />

m-trifluoromethylphenyl trimethylammonium hydroxide.<br />

This one-step reagent simplifies the transesterification<br />

of triglycerides to methyl esters. It is faster than sodium<br />

methoxide and the reaction occurs at room temperature.<br />

This quantitative reaction requires no extractions or additional<br />

treatment prior to gas chromatographic analysis.<br />

Meth-Prep II<br />

Description Qty. Part No.<br />

Meth-Prep II 10 x 1mL 18007<br />

standards and reagents<br />

Instant Methanolic HCl Reagent Kit<br />

• Acid catalyzed esterification of alcohols<br />

• Reagent is generated before use and is stable for one<br />

week at room temperature<br />

Instant Methanolic HCl Reagent Kit<br />

Description Qty. Part No.<br />

Instant Methanolic HCl Reagent Kit ea 18053<br />

Anhydrous Acetyl Chloride 5 x 2.8mL 18095<br />

Anhydrous Methanol 10 x 5mL 18157<br />

4801<br />

related product<br />

Looking for syringes to use<br />

with reagents?<br />

See page 337–342.<br />

Sodium Methoxide/Methanol<br />

• Converts a wide range of large esters to fatty acid<br />

methyl esters<br />

Sodium Methoxide/Methanol<br />

Description Qty. Part No.<br />

Sodium Methoxide/Methanol 10 x 5mL 18018<br />

Sodium Methoxide/Methanol 25mL 218025<br />

related product<br />

Looking for amino acid derivatization kits?<br />

See page 63.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

326 www.discoverysciences.com


general chromatography<br />

Acylation<br />

Acylation reduces the polarity of amino, hydroxyl and thiol<br />

groups on multi-functional molecules such as carbohydrates<br />

and amino acids.<br />

Acetic Anhydride/Pyridine<br />

• Used for acetylation of alcoholic and phenolic hydroxyl<br />

groups; and primary and secondary amino groups<br />

Acetic Anhydride/Pyridine<br />

Description Qty. Part No.<br />

Acetic Anhydride/Pyridine Kit ea 18100<br />

Acetic Anhydride 10 x 1mL 18103<br />

Pyridine-Plus<br />

• Much more powerful than acetic anhydride/pyridine<br />

• Rapid reaction and fewer byproducts<br />

Pyridine-Plus<br />

Description Qty. Part No.<br />

Pyridine-Plus Kit ea 18105<br />

Fluorinated Imidazoles<br />

• No acidic byproducts compared to anhydride reagents<br />

Fluorinated Imidazoles<br />

Description Qty. Part No.<br />

TFAI (N-Trifluoroacetylimidazole) 10 x 0.2g 18046<br />

HFBI (N-Heptafluorobutyrylimidazole) 10 x 0.2g 18048<br />

Perfluoroalkyl Anhydrides<br />

• Produces derivatives suitable to electron capture<br />

detection<br />

Perfluoroalkyl Anhydrides<br />

Description Qty. Part No.<br />

Trifluoroacetic Anhydride 5 x 1mL 18083<br />

Pentafluoropropionic Anhydride 25g 65192<br />

Pentafluoropropionic Anhydride 5 x 1mL 18116<br />

Heptafluorobutyric Anhydride 25g 63163<br />

Heptafluorobutyric Anhydride 5 x 1mL 18118<br />

related products<br />

Looking for reaction vials to<br />

use with reagents?<br />

See page 375.<br />

Specialty Reagents<br />

Amino Acid Derivatization Kits<br />

• Simple two-step procedure<br />

• Three different reagents available: TFA, PFP, and HFB<br />

Amino Acid Derivatization Kits<br />

Description Qty. Part No.<br />

TFA-IPA Derivatization Kit ea 18092<br />

PFP-IPA Derivatization Kit ea 18093<br />

HFB-IPA Derivatization Kit ea 18094<br />

Barb-Prep<br />

• On-column methylation of barbiturates<br />

• No byproduct formation<br />

Barb-Prep<br />

Description Qty. Part No.<br />

Barb-Prep 10 x 1mL 18009<br />

DMF-DMA<br />

• Novel reagent for derivatization of fatty acids, amino<br />

acids, amines, and barbiturates<br />

DMF-DMA<br />

Description Qty. Part No.<br />

DMF-DMA 10 x 1mL 18051<br />

LC Reagents<br />

UV Enhancing<br />

UV Enhancing<br />

Description Qty. Part No.<br />

p-Bromophenacyl Derivatization Kit — 18036<br />

p-Nitrobenzyloxyamine HCl (PNBA) 1g 510113<br />

Fluorescence Enhancing<br />

Fluorescence Enhancing<br />

Description Qty. Part No.<br />

o-Phthalaldehyde (OPA) 5g 35606<br />

standards and reagents<br />

4758<br />

www.discoverysciences.com<br />

327


general chromatography<br />

IPC Reagents<br />

• Comparable to Waters ® PIC ® Reagents<br />

• Preformulated at optimum concentration and pH<br />

• Convenient—Simply dilute with HPLC grade solvents<br />

“A” Series<br />

• Used for chromatography of acidic compounds<br />

“B” Series<br />

• Used for chromatography of basic compounds<br />

A Series and B Series<br />

Description Qty. Part No.<br />

IPC A, Tetrabutylammonium Phosphate 5 x 15mL 185101<br />

IPC B5, Sodium Pentanesulfonate 5 x 25mL 185110<br />

IPC B7, Sodium Heptanesulfonate 5 x 25mL 185103<br />

“Low UV”* Series<br />

• Suitable for use at wavelengths down to 200nm<br />

Low UV Series<br />

Description Qty. Part No.<br />

Low UV IPC A, Tetrabutylammonium Sulfate 5 x 20mL 185149<br />

Low UV IPC B5, Tetrabutylammonium Phosphate 5 x 20mL 184198<br />

Low UV IPC B6, Tetrabutylammonium Phosphate 5 x 20mL 184199<br />

Low UV IPC B7, Tetrabutylammonium Phosphate 5 x 20mL 184282<br />

Low UV IPC B8, Tetrabutylammonium Phosphate 5 x 20mL 184283<br />

*For use at wavelengths below 240nm.<br />

Table 1—IPC Reagents<br />

<strong>Grace</strong><br />

IPC A<br />

IPC B5<br />

IPC B6<br />

IPC B7<br />

IPC B8<br />

Low UV IPC A<br />

Low UV IPC B5<br />

Low UV IPC B6<br />

Low UV IPC B7<br />

Low UV IPC B8<br />

1 2<br />

3<br />

IPC B7 Reagent<br />

4<br />

Waters<br />

PIC ® A<br />

PIC ® B5<br />

PIC ® B6<br />

PIC ® B7<br />

PIC ® B8<br />

Low UV PIC ® A<br />

Low UV PIC ® B5<br />

Low UV PIC ® B6<br />

Low UV PIC ® B7<br />

Low UV PIC ® B8<br />

5870<br />

1. Niacinamide<br />

2. Riboflavin<br />

3. Pyridoxine<br />

4. Thiamine<br />

Ion-Pair Salts<br />

<strong>Grace</strong> offers high-purity ion-pairing salts for those wishing to<br />

formulate their own mobile phases.<br />

standards and reagents<br />

• High purity for HPLC applications<br />

Ion-Pair Salts<br />

Description Qty. Part No.<br />

1-Pentanesulfonate 25g 403125<br />

1-Hexanesulfonate 25g 403126<br />

1-Heptanesulfonate 25g 403127<br />

1-Octanesulfonate 25g 403128<br />

Tetrabutylammonium Phosphate, 0.5M, pH 7.5) 10mL 680502<br />

0 2<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

4<br />

6<br />

8 Min.<br />

Adsorbosphere HS C18, 7µm,<br />

4.6 x 250mm HPLC Column<br />

Methanol:Water (50:50) both with IPC B7<br />

1.0mL/min<br />

UV at 254nm<br />

related products<br />

Looking for mobile phase<br />

storage bottles?<br />

See page 125–127.<br />

5595<br />

328 www.discoverysciences.com


general chromatography<br />

Gas Standards<br />

• Portable, lightweight, and easy-to-use disposable cylinders<br />

• Each standard comes with a certificate of analysis<br />

MicroMAT-10<br />

10L Disposable Cylinder<br />

6346 6347 6675<br />

MicroMAT-14<br />

14L Disposable Cylinder<br />

MicroMAT-58<br />

58L Disposable Cylinder<br />

Single Component Gas Standards<br />

Single Component Mixtures<br />

Analyte/Concentration Balance Cylinder Size Part No.<br />

Acetylene<br />

1% Helium MicroMAT-10 G0413<br />

1% Nitrogen MicroMAT-10 G0423<br />

Argon<br />

99.995% — MicroMAT-14 M7003<br />

Carbon Dioxide<br />

99.80% — MicroMAT-14 M7006<br />

100ppm Helium MicroMAT-10 G1211<br />

1000ppm Helium MicroMAT-10 G1212<br />

1% Helium MicroMAT-10 G1213<br />

10% Helium MicroMAT-10 G1214<br />

Carbon Monoxide<br />

1000ppm Helium MicroMAT-10 24047<br />

10% Helium MicroMAT-10 24054<br />

Ethane<br />

99.00% — MicroMAT-14 M7012<br />

Ethylene<br />

100ppm Helium MicroMAT-10 G0311<br />

100ppm Helium MicroMAT-14 M7030<br />

1000ppm Helium MicroMAT-10 G0312<br />

1000ppm Nitrogen MicroMAT-14 24022<br />

8-10ppm Air MicroMAT-14 24096<br />

Helium<br />

99.995% — MicroMAT-14 M7005<br />

Hydrogen<br />

99.99% — MicroMAT-14 M7004<br />

100ppm Nitrogen MicroMAT-14 M7125<br />

1000ppm Nitrogen MicroMAT-10 G1522<br />

1% Nitrogen MicroMAT-10 G1523<br />

Nitrogen<br />

99.998% — MicroMAT-14 M7002<br />

Single Component Mixtures<br />

Analyte/Concentration Balance Cylinder Size Part No.<br />

Nitrous Oxide<br />

98.00% — MicroMAT-14 M7009<br />

0.1ppm Nitrogen MicroMAT-14 24042<br />

1.0ppm Nitrogen MicroMAT-14 24044<br />

100ppm Nitrogen MicroMAT-10 G1721<br />

1000ppm Nitrogen MicroMAT-10 G1722<br />

Methane<br />

99.00% — MicroMAT-14 M7011<br />

100ppm Helium MicroMAT-10 G0111<br />

1000ppm Helium MicroMAT-10 G0112<br />

1% Helium MicroMAT-10 G0113<br />

10% Helium MicroMAT-14 24066<br />

100ppm Nitrogen MicroMAT-14 M7029<br />

1% Nitrogen MicroMAT-10 G0123<br />

10% Nitrogen MicroMAT-14 24067<br />

10ppm Air MicroMAT-14 19781<br />

Oxygen<br />

99.5% — MicroMAT-14 M7001<br />

100ppm Helium MicroMAT-14 M7121<br />

1% Helium MicroMAT-10 G1613<br />

1% Nitrogen MicroMAT-10 G1623<br />

2% Nitrogen MicroMAT-14 24094<br />

6% Nitrogen MicroMAT-14 24095<br />

10% Nitrogen MicroMAT-10 G1624<br />

Propane<br />

99.00% — MicroMAT-14 M7014<br />

Vinyl Chloride (NIST Traceable)<br />

10ppm Nitrogen MicroMAT-14 G2001<br />

1000ppm Nitrogen MicroMAT-14 G2004<br />

standards and reagents<br />

www.discoverysciences.com<br />

329


general chromatography<br />

Multi-Component Gas Mixtures<br />

standards and reagents<br />

Multi-Component Gas Mixtures<br />

Description Concentration Cylinder Size Part No.<br />

BTEX in Nitrogen<br />

Benzene, Ethylbenzene, Toluene, Xylene 1ppm (mix) MicroMAT-58 24076<br />

10ppm (mix) MicroMAT-58 24099<br />

100ppm (mix) MicroMAT-58 24115<br />

C2 to C4 Alkyne in Nitrogen<br />

Acetylene, 1-Butyne, 2-Butyne, Propyne 15ppm each MicroMAT-10 19797<br />

C1 to C4 Hydrocarbons in Nitrogen<br />

Methane, Ethane, Ethylene, Acetylene, Propane, Propylene, Propyne,<br />

15ppm each MicroMAT-14 24130<br />

n-Butane<br />

C4 Hydrocarbons in Nitrogen<br />

n-Butane, Isobutane, 2-Butene (cis and trans), 1-Butene, Isobutylene,<br />

15ppm each MicroMAT-14 24132<br />

1,3-Butadiene, Ethyl Acetylene<br />

2-Olefin Mixture in Nitrogen<br />

2-Butene (cis and trans), 2-Pentene (cis and trans), 2-Hexene (cis<br />

15ppm each MicroMAT-14 19775<br />

and trans)<br />

C2 to C6 Olefin Mixture in Helium<br />

Ethylene, Propylene, 1-Butene, 1-Pentene, 1-Hexene 100ppm each MicroMAT-14 19784<br />

1000ppm each MicroMAT-14 M7020<br />

C2 to C6 Olefin Mixture in Nitrogen<br />

Ethylene, Propylene, 1-Butene, 1-Pentene, 1-Hexene 1000ppm each MicroMAT-14 M7019<br />

C1 to C6 n-Paraffin Mixture in Helium<br />

Methane, Ethane, Propane, Butane, Pentane, Hexane 100ppm each MicroMAT-14 19782<br />

1000ppm each MicroMAT-14 M7018<br />

C1 to C6 n-Paraffin Mixture in Nitrogen<br />

Methane, Ethane, Propane, Butane, Pentane, Hexane 15ppm each MicroMAT-14 19772<br />

100ppm each MicroMAT-14 19783<br />

1000ppm each MicroMAT-14 M7017<br />

Branched Paraffin Mixture in Nitrogen<br />

Isobutane, 2-Methylbutane, 2,2-Dimethylpropane, 2-Methylpentane,<br />

15ppm each MicroMAT-14 19774<br />

3-Methylpentane, 2,2-Dimethylbutane<br />

CO and CO2 in Nitrogen<br />

Carbon Monoxide, Carbon Dioxide 25ppm (CO), 1000ppm (CO2) MicroMAT-14 24136<br />

CO, CO2, Methane, Ethane, Ethylene, Acetylene in Nitrogen<br />

1% each MicroMAT-14 M7035<br />

CO, CO2, Methane, H2, O2 in Nitrogen<br />

1% each MicroMAT-14 M7036<br />

CO, CO2, CH4, H2, O2, N2 in Helium<br />

Carbon Monoxide, Carbon Dioxide, Methane, Hydrogen, Oxygen, Nitrogen<br />

5% (CO), 5% (CO2), 4% (CH4), 4% (H2),<br />

5% (O2), 5% (N2)<br />

MicroMAT-14 19792<br />

CO, CO2, O2 in Nitrogen<br />

Carbon Monoxide, Carbon Dioxide, Oxygen 7% (CO), 15% (CO2), 3% (O2) MicroMAT-14 M7041<br />

CO, CO2, CH4, O2 in Nitrogen<br />

Carbon Monoxide Carbon Dioxide, Methane, Oxygen 7% (CO), 15% (CO2), 4.5% (CH4), 7% (O2) MicroMAT-14 19791<br />

CO, CO2, H2, O2 in Nitrogen<br />

0.5% each MicroMAT-14 24138<br />

0.5% each (CO, CO2, O2), 5% H2 MicroMAT-14 M7037<br />

CO2, O2 in Nitrogen<br />

1% each MicroMAT-14 24029<br />

1% (CO2), 2% (O2) MicroMAT-14 M7040<br />

2% (CO2), 24% (O2) MicroMAT-14 24034<br />

330 www.discoverysciences.com


general chromatography<br />

Special Gas Standards<br />

Reactive Gas Standards<br />

Reactive Gas Standards<br />

Description Concentration Cylinder Size Part No.<br />

Hydrogen Sulfide in 10ppm MicroMAT-58 24102<br />

Nitrogen<br />

95ppm MicroMAT-58 24105<br />

Nitric Oxide in Nitrogen 20-30ppm MicroMAT-58 24107<br />

Hardware for Using Gas<br />

Cylinders<br />

MicroMAT-10 Syringe Adapter<br />

• Maximum pressure 120psig<br />

Natural Gas Standards<br />

• Certificate of analysis<br />

• Shelf life one year<br />

Natural Gas Standards Concentrations<br />

GPA Calorimetric High Ethane Helium-Enriched<br />

Helium 0.50 — — 2.00<br />

Nitrogen 5.00 2.50 9.00 1.60<br />

Carbon Dioxide 1.00 3.00 0.50 0.20<br />

Ethane 9.00 3.50 12.50 3.00<br />

Propane 6.00 1.00 7.00 1.70<br />

Isobutane 3.00 0.40 3.00 1.00<br />

n-Butane 3.00 0.40 3.00 1.00<br />

Isopentane 1.00 0.15 0.50 0.30<br />

n-Pentane 1.00 0.15 0.50 0.30<br />

Neopentane — 0.10 — —<br />

n-Hexane — 0.05 — —<br />

n-Heptane — 0.02 — —<br />

Methane Balance Balance Balance Balance<br />

MicroMAT-10 Syringe Adapter<br />

Description Cylinder Size Part No.<br />

Aerosol Syringe Adapter MicroMAT-10 8048<br />

Replacement Septa, 12/pk — 75801<br />

MicroMAT-14 Syringe Adapter<br />

• Maximum pressure 240psig<br />

• May be used with any<br />

1/8" NPT (F) outlet<br />

MicroMAT-10 Syringe<br />

Adapter<br />

5386<br />

Natural Gas Standards<br />

Description Concentration Cylinder Size Part No.<br />

Natural Gas GPA<br />

See above MicroMAT-14 24100<br />

Standard<br />

Natural Gas Calorimetric See above MicroMAT-14 24116<br />

Standard<br />

Natural Gas High Ethane See above MicroMAT-14 24128<br />

Standard<br />

Natural Gas Helium-<br />

Enriched Standard<br />

See above MicroMAT-14 24131<br />

related product<br />

Looking for Gastight syringes?<br />

See pages 339–340.<br />

5156<br />

MicroMAT-58 Regulator<br />

• Stainless steel with hose<br />

barb outlet<br />

• Push button on/off control<br />

• Preset 0.3SLPM flow rate<br />

MicroMAT-14 Syringe<br />

Adapter<br />

MicroMAT-14 Syringe Adapter<br />

Description Cylinder Size Part No.<br />

Syringe Adapter MicroMAT-14 8810<br />

Replacement Septa, 10/pk — 8812<br />

5385<br />

standards and reagents<br />

MicroMAT-58 Regulator<br />

Description Cylinder Size Part No.<br />

0–30psig, C-10 Valve MicroMAT-58 37201<br />

6674<br />

MicroMAT-58 Regulator<br />

www.discoverysciences.com<br />

331


general chromatography<br />

Fatty Acid and Methyl Ester Standards<br />

• Quality certificate supplied with every standard and mix<br />

Fatty Acid and Methyl Ester Standards<br />

Free Fatty Acids<br />

Fatty Acid Methyl Esters<br />

Carbon # Description Qty. Part No. Qty. Part No.<br />

11:0 Henedecanoic Acid (Undecylic) 0.5g 622110 0.5g 623110<br />

12:0 Dodecanoic Acid (Lauric) 1g 622120 1g 623120<br />

13:0 Tridecanoic Acid (Tridecylic) 1g 622130 1g 623130<br />

14:0 Tetradecanoic Acid (Myristic) 1g 623140 1g 623140<br />

15:0 Pentadecanoic Acid (Pentadecylic) 0.5g 622150 0.5g 623150<br />

16:0 Hexadecanoic Acid (Palmitic) 1g 622160 1g 623160<br />

16:1 cis-9-Hexadecenoic Acid (Palmitoleic) 0.1g 6221610 0.1g 6231610<br />

17:0 Heptadecanoic Acid (Margaric) 1g 622170 1g 623170<br />

18:0 Octadecanoic Acid (Stearic) 1g 622180 1g 623180<br />

18:1 cis-9-Octadecenoic Acid (Oleic) 1g 6221810 1g 6231810<br />

18:1 trans-9-Octadecenoic Acid (Elaidic) 1g 6221811 0.5g 6231811<br />

18:1 cis-11-Octadecenoic Acid (cis-Vaccenic) — — 0.1g 62318101<br />

18:1 trans-11-Octadecenoic Acid (trans-Vaccenic) — — 0.1g 62318121<br />

18:2 cis, cis-9,12-Octadecadienoic Acid (Linoleic) 1g 6221820 1g 6231820<br />

18:2 trans,trans-9,12-Octadecadienoic Acid (Linoelaidic) 0.1g 6221821 0.1g 6231821<br />

18:3 All cis-9,12,15-Octadecatrienoic Acid (Linolenic) 0.1g 62218300 0.1g 6231830<br />

18:3 All cis-6,9,12-Octadecatrienoic Acid (γ-Linolenic) 0.1g 62218301 0.1g 6231831<br />

20:0 Eicosanoic Acid (Arachidic) 1g 6220200 1g 623200<br />

20:1 cis-11-Eicosenoic Acid 0.1g 6220201 0.1g 623201<br />

20:4 All cis-5,8,11,14-Eicosatetraenoic Acid (Arachidonic) 0.1g 6220204 0.1g 623204<br />

20:5 All cis-5,8,11,14,17-Eicosapentaenoic Acid 10mg 6220205 10mg 623205<br />

22:0 Docosanoic Acid (Behenic) 1g 6220220 1g 623220<br />

22:5 All cis-7,10,13,16,19-Docosapentaenoic Acid 10mg 6220225 10mg 6232250<br />

23:0 Tricosanoic Acid 0.1g 6220230 0.1g 623230<br />

24:0 Tetracosanoic Acid (Lignoceric) 0.1g 6220240 0.1g 623240<br />

standards and reagents<br />

Fatty Acid Methyl Ester Mixes<br />

Description Components Qty. Part No.<br />

K101 C8:0, C10:0, C12:0, C14:0, C16:0, C18:0, C20:0 100mg 625001<br />

K103 C12:0, C14:0, C14:1, C16:0, C16:1 cis 50mg 625002<br />

K1000 C13:0, C15:0, C17:0, C19:0, C21:0 50mg 625003<br />

K104 C14:0, C16:0, C18:0, C20:0, C22:0, C24:0 100mg 625004<br />

K110 C16:0, C16:1 cis, C16:1 trans, C18:0, C18:1 cis-9, C18:1 trans-9, C18:2 cis,cis, C18:2 trans,trans 100mg 625005<br />

K108 C16:0, C18:0, C18:1 cis-9, C18:2 cis,cis, C18:3 all cis 50mg 625006<br />

K2000 C18:0, C18:1 cis-9, C18:2 cis,cis, C18:3 all cis, C20:4 all cis 50mg 625007<br />

K3000 C18:2 cis,cis, C18:3 all cis, C20:4 all cis, C22:6 all cis 50mg 625008<br />

K4000 C20:0, C20:1 cis, C20:2 cis,cis, C20:3 all cis, C20:4 all cis 50mg 625009<br />

K107 C20:0, C20:1 cis, C22:0, C22:1 cis, C24:0, C24:1 cis 50mg 625010<br />

K5000 Mix A C6:0, C8:0, C10:0, C12:0 100mg in 5mL 625017<br />

K5000 Mix B C12:0, C14:0, C16:0, C18:0 100mg in 5mL 625018<br />

L207 C18:0, C18:1 cis-9, C20:0, C22:0, C22:1 cis, C24:0, C24:1 cis 50mg 625021<br />

L205 C18:0, C18:1 cis-9, C18:2 cis,cis, C18:3 all cis, C20:4 all cis 100mg 625022<br />

L209 C20:0, C20:1 cis, C20:4 all cis, C22:1 cis, C22:6 all cis 25mg 625023<br />

AOCS Mix 1 C16:0, C18:0, C18:1 cis-9, C18:2 cis,cis, C18:3 all cis, C20:0 50mg 625024<br />

AOCS Mix 3 C16:0, C18:0, C18:1 cis-9, C18:2 cis,cis, C18:3 all cis, C20:0, C22:0, C22:1 cis, C24:0 50mg 625026<br />

AOCS Mix 3A C16:0, C18:0, C18:1 cis-9, C18:2 cis,cis, C18:3 all cis, C20:0, C20:1 cis, C22:0, C22:1 cis, C24:0 25mg 625027<br />

AOCS Mix 5 C8:0, C10:0, C12:0, C14:0, C16:0, C18:0, C18:1 cis-9, C18:2 cis,cis 50mg 625029<br />

AOCS Mix 6 C14:0, C16:0, C16:1 cis, C18:0, C18:1 cis-9, C18:2 cis,cis, C18:3 all cis 50mg 625030<br />

332 www.discoverysciences.com


general chromatography<br />

Hydrocarbons and Miscellaneous Standards and Kits<br />

• Quality certificate supplied with every standard and mix<br />

Use Standards and Mixes with complete confidence in purity<br />

and quality. Don’t waste your valuable lab time to verify the<br />

standards you need. To satisfy your documentation needs,<br />

<strong>Grace</strong> supplies a purity certificate for every standard and mix.<br />

Organic Acid Standards<br />

Description Qty. Part No.<br />

Oxalic Acid, 1000ppm 125mL 37033<br />

Maleic Acid, 1000ppm 125mL 37037<br />

Malic Acid, 1000ppm 125mL 37039<br />

Succinic Acid, 1000ppm 125mL 37043<br />

Formic Acid, 1000ppm 125mL 37045<br />

Acetic Acid, 1000ppm 125mL 37047<br />

Citric Acid, 1000ppm 125mL 37049<br />

Tartaric Acid, 1000ppm 125mL 37051<br />

Lactic Acid, 1000ppm 125mL 37053<br />

Abietic Acid, 1000ppm 125mL 37055<br />

Methane Sulfonic Acid, 1000ppm 125mL 37057<br />

n-Paraffin Mixtures<br />

Description Qty. Part No.<br />

Neat Mixtures (No Solvent— Equal Weights of Components)<br />

C5, C6, C7, C8 2mL 628001<br />

C7, C8, C9, C10 2mL 628002<br />

C9, C10, C11, C12 2mL 628003<br />

C11, C12, C13, C14 2mL 628004<br />

C12, C14, C16, C18 2mL 628005<br />

Mixtures (In 5mL Hexane — Equal Weight of Components)<br />

C16, C18, C20, C22 0.5g 628006<br />

C20, C22, C24, C26 0.1g 628007<br />

C24, C26, C28, C30 50mg 628008<br />

C28, C30, C32, C34 50mg 628009<br />

C32, C34, C36, C38 50mg 628010<br />

Hydrocarbons (n-Paraffins)<br />

Carbon No. Description Qty. Part No.<br />

C5 n-Pentane 1g 620050<br />

C6 n-Hexane 1g 620060<br />

C7 n-Heptane 1g 620070<br />

C8 n-Octane 1g 6<strong>2008</strong>0<br />

C9 n-Nonane 1g 620090<br />

C10 n-Decane 1g 620100<br />

C11 n-Hendecane 1g 620110<br />

C12 n-Dodecane 1g 620120<br />

C13 n-Tridecane 1g 620130<br />

C14 n-Tetradecane 1g 620140<br />

C15 n-Pentadecane 1g 620150<br />

C16 n-Hexadecane 1g 620160<br />

C17 n-Heptadecane 1g 620170<br />

C18 n-Octadecane 1g 620180<br />

C19 n-Nonadecane 1g 620190<br />

C20 n-Eicosane 1g 620200<br />

C21 n-Heneicosane 1g 620210<br />

C22 n-Docosane 1g 620220<br />

C23 n-Tricosane 1g 620230<br />

C24 n-Tetracosane 1g 620240<br />

C25 n-Pentacosane 0.1g 620250<br />

C26 n-Hexaconsane 0.1g 620260<br />

C27 n-Heptacosane 0.1g 620270<br />

C28 n-Octacosane 1g 620280<br />

C29 n-Nonacosane 0.1g 620290<br />

C30 n-Triacontane 0.1g 620300<br />

C32 n-Dotriacontane 0.1g 620320<br />

C34 n-Tetratriacontane 0.1g 620340<br />

C36 n-Hexatriacontane 0.1g 620360<br />

C38 n-Octatriacontane 0.1g 620380<br />

C40 n-Tetracontane 0.1g 620400<br />

C44 n-Tetratetracontane 0.1g 620440<br />

Aromatic Hydrocarbon Mix<br />

Description Qty. Part No.<br />

BETX Mix 2g 629001<br />

Contains equal amounts of benzene, toluene, ethylbenzene, o-xylene, m-xylene, and<br />

p-xylene.<br />

Standards Kits<br />

Description Kit Contains 100mg Each Component Part No.<br />

Free Fatty Acid Kits<br />

Short Chain C2, C3, C4, C5, C6, C7, C8 18600<br />

Even Carbon C10, C12, C14, C16, C18, C20, C22 186021<br />

Odd Carbon C9, C11, C13, C15, C17, C19, C21, C23 18608<br />

Fatty Acid Ester Kits<br />

Methyl Esters, Even Carbon C10, C12, C14, C16, C18, C20, C22 18603<br />

Methyl Esters, Odd Carbon C9, C11, C13, C15, C17, C19, C21 18609<br />

Ethyl Esters, Even Carbon C6, C8, C10, C12, C14, C16, C18, C20, C22, C24 18610<br />

Ethyl Esters, Odd Carbon C7, C9, C11, C13, C15, C17, C19, C21, C23 18611<br />

Hydrocarbon Kits<br />

Saturated, Even Carbon C10, C12, C14, C16, C18, C20, C22, C24, C28, C32, C36 18484<br />

Saturated, Odd Carbon C9, C11, C13, C15, C17, C19, C21, C23, C25 18485<br />

standards and reagents<br />

www.discoverysciences.com<br />

333


general chromatography<br />

Alltech ® IC Standards<br />

• High purity for sensitive applications<br />

• Prepared from NIST standard reference materials<br />

• Certified by two independent methods<br />

• Detailed Certificate of Analysis included<br />

Certified Organic Anion Standards<br />

Organic Anion Standards (125mL)<br />

1000ppm<br />

Description<br />

Part No.<br />

Acetate 37052<br />

Citrate 37091<br />

Formate 37050<br />

Glycolate 37054<br />

Lactate 37093<br />

Malate 37095<br />

Maleate 37099<br />

Methanesulfonate 37221<br />

Nitrilotriacetate (NTA) 37228<br />

Oxalate 37056<br />

Propionate 37229<br />

Succinate 37223<br />

Tartrate 37224<br />

3493<br />

Certified Organic Acid Standards<br />

standards and reagents<br />

Certified Anion and Cation Standards<br />

Anion Standards (125mL)<br />

1000ppm<br />

Part No.<br />

200ppm<br />

Part No.<br />

Description<br />

Bromate 37058 —<br />

Bromide 37005 37006<br />

Chlorate 37034 —<br />

Chloride 37009 37010<br />

Chlorite 37038 —<br />

Chromate 37042 —<br />

Fluoride 37011 37012<br />

Iodide 37013 —<br />

Nitrate 37019 37020<br />

Nitrate-N 37234 —<br />

Nitrite 37021 37022<br />

Nitrite-N 37235 —<br />

Perchlorate 37048 —<br />

Phosphate 37023 37024<br />

Phosphate-P 37236 —<br />

Sulfate 37031 37032<br />

Thiocyanate 37046 —<br />

Cation Standards (125mL)<br />

1000ppm<br />

Part No.<br />

200ppm<br />

Part No.<br />

Description<br />

Ammonium 37001 37002<br />

Ammonium-N 37233 —<br />

Calcium 37007 37008<br />

Lithium 37015 37016<br />

Magnesium 37017 37018<br />

Potassium 37025 37026<br />

Sodium 37029 37030<br />

Organic Acid Standards (125mL)<br />

1000ppm<br />

Description<br />

Part No.<br />

Oxalic Acid 37033<br />

Maleic Acid 37037<br />

Malic Acid 37039<br />

Succinic Acid 37043<br />

Formic Acid 37045<br />

Acetic Acid 37047<br />

Citric Acid 37049<br />

Tartaric Acid 37051<br />

Lactic Acid 37053<br />

Abietic Acid 37055<br />

Methanesulfonic Acid 37057<br />

Certified Amine Standards<br />

Amine Standards (125mL)<br />

1000ppm<br />

Description<br />

Part No.<br />

Ethanolamine 37225<br />

Diethanolamine 37226<br />

Triethanolamine 37227<br />

Monomethylamine 37230<br />

Dimethylamine 37231<br />

Trimethylamine 37232<br />

334 www.discoverysciences.com


general chromatography<br />

Alltech ® IC Standards<br />

Certified Multi-Standard Kits<br />

• Cost-effective ways to purchase multiple single-ion<br />

standards<br />

Multi-Standard Kits<br />

Description<br />

Anion Kits<br />

200ppm Kit: Contains 125mL ea of 200ppm<br />

Certified Cl, F, Br, NO3, NO2, PO4, and SO4<br />

1000ppm Kit: Contains 125mL ea of 1000ppm<br />

Certified Cl, F, Br, NO3, NO2, PO4, and SO4<br />

Anion and Oxyhalide Kit: (EPA 300.1Part B) Contains<br />

125mL ea of 200ppm certified Cl, F, Br, NO3, NO2, PO4,<br />

and SO4, ClO2, ClO3, BrO3<br />

Cation Kits<br />

200ppm Kit: Contains 125mL ea of 200ppm<br />

Certified Li, Na, NH4, K, Mg, and Ca<br />

1000ppm Kit: Contains 125mL ea of 1000ppm<br />

Certified Li, Na, NH4, K, Mg, and Ca<br />

best<br />

value<br />

Part No.<br />

37035<br />

37036<br />

37085<br />

37040<br />

37041<br />

EZ-LUTE Buffer<br />

Concentrates<br />

• Simplify mobile phase preparation<br />

• For anion, cation, and organic acid analyses<br />

• Dilution instructions included<br />

Certified Multi-Component Mixtures<br />

• Multiple ions in a single mixture<br />

Multi-Component Mixtures (125mL)<br />

Description<br />

Anion Mixtures<br />

Mix A: 125mL Mixture Contains:<br />

F(10ppm), Cl(20ppm), O2(20ppm), Br(20ppm),<br />

NO3(20ppm), PO4(30ppm), SO4(30ppm)<br />

Mix 1: 125mL Mixture Contains:<br />

F(1ppm), Cl(5ppm), NO2(5ppm), Br(5ppm), NO3(5ppm),<br />

PO4(5ppm), SO4(5ppm)<br />

Mix 2: 125mL Mixture Contains:<br />

F(1ppm), Cl(10ppm), NO2(10ppm), Br(10ppm),<br />

NO3(10ppm), PO4(10ppm), SO4(10ppm)<br />

Mix 3: 125mL Mixture Contains:<br />

F(10ppm), Cl(20ppm), NO2(20ppm), Br(20ppm),<br />

NO3(20ppm), PO4(20ppm), SO4(20ppm)<br />

Mix 4: 125mL Mixture Contains:<br />

F(20ppm), Cl(40ppm), NO2(40ppm), Br(40ppm),<br />

NO3(40ppm), PO4(40ppm), SO4(40ppm)<br />

Mix 5: 125mL Mixture Contains:<br />

F(25ppm), Cl(50ppm), NO2(50ppm), Br(50ppm),<br />

NO3(50ppm), PO4(50ppm), SO4(50ppm)<br />

Mix 6: 125mL Mixture Contains:<br />

Cl(1000ppm), Br(1000ppm), NO3(1000ppm),<br />

PO4(1000ppm), SO4(1000ppm)<br />

Mix 7: 125mL Mixture Contains:<br />

Cl(15ppm), Br(15ppm), NO3(15ppm),<br />

PO4(15ppm), SO4(5ppm)<br />

Mix 8: 125mL Mixture Contains:<br />

F(25ppm), Cl(50ppm), SO4(100ppm)<br />

Cation Mixtures<br />

Mix A: 125mL Mixture Contains:<br />

Li(0.5ppm), Na(3ppm), NH4(3ppm), K(6ppm)<br />

Mix B: 125mL Mixture Contains:<br />

Li(0.2ppm), Na(1.5ppm), NH4(1.5ppm), K(2.5ppm),<br />

Mg(2.0ppm), Ca(2.0ppm)<br />

Part No.<br />

26910200<br />

269106<br />

269107<br />

269108<br />

269109<br />

269110<br />

269111<br />

269112<br />

269113<br />

26910300<br />

26910400<br />

EZ-LUTE Buffers for accurate concentrations every time.<br />

EZ-LUTE Buffer Concentrates*<br />

Description<br />

Part No.<br />

Non-suppressed Buffers, 12 x 25mL<br />

4mM Phthalic Acid 470217<br />

4mM Phthalic Acid, pH 4.5 470216<br />

4mM p-Hydroxybenzoic Acid 470212<br />

5mM p-Hydroxybenzoic Acid 470215<br />

7mM p-Hydroxybenzoic Acid 470214<br />

5mM LiOH/Benzoate 470213<br />

3mM Methanesulfonic Acid 470211<br />

Suppressor-based Buffers, 1 x 100mL<br />

1.7mM Bicarbonate/1.8mM Carbonate 470119<br />

2.8mM Bicarbonate/2.2mM Carbonate 470201<br />

2.1mM Bicarbonate/1.6mM Carbonate 470203<br />

0.85mM Bicarbonate/0.9mM Carbonate 470208<br />

0.7mM Bicarbonate/1.2mM Carbonate 470122<br />

3.6mM Carbonate 470123<br />

500mM Bicarbonate 470209<br />

500mM Carbonate 470210<br />

*Concentration after dilution.<br />

more info<br />

Custom Standards Available<br />

If you need it, we can make it, whether a single ion or a complex<br />

mixture. Request a quote for part number C2690, in any volume<br />

from 125mL to 1-liter. Fast delivery!<br />

6561<br />

standards and reagents<br />

www.discoverysciences.com<br />

335


general chromatography<br />

Syringe Selection Guide<br />

Syringe Selection Guide<br />

Manufacturer Type Description Page #<br />

Hamilton ® Syringes<br />

Series 600 General purpose, 2.5µL to 5µL 338<br />

Series 700 General purpose, 5µL to 500µL 338<br />

Series 900 Economical syringe with reinforced plunger, 5µL to 10µL 338<br />

Series 800 General purpose with reinforced plunger, 5µL to 250µL 339<br />

Series 1000 Gas and liquid tight, 1mL to 100mL 339<br />

Series 7000 Plunger-in-needle, 0.5µL to 5µL 339<br />

Series 1700 Gas and liquid tight, 10µL to 500µL 340<br />

Series 1800 Gas and liquid tight with reinforced plunger, 10µL to 250µL 340<br />

Super Gas Gas tight, large volume acrylic, 500mL to 2000mL 340<br />

SampleLock 1000 and 1700 Series syringes with twist valve to lock sample in 341<br />

Autosampler 700 and 1700 Series syringes compatible with many popular autosamplers 341<br />

VICI ® -Precision Syringes<br />

Series A Gas tight with a twist valve for sample storage, 100µL to 10mL 343<br />

Series A-2 Gas tight with a push-button valve for sample storage, 25µL to 10mL 343<br />

SGE ® Syringes<br />

Standard General purpose, 5µL and 10µL 344<br />

Plunger Protection General purpose with reinforced plunger, 5µL and 10µL 344<br />

SuperfleX General purpose with flexible plunger, 5µL and 10µL 344<br />

Factory Calibrated NIST and NBS traceable, 5µL to 500µL 344<br />

Guided Plunger Extended barrel and reinforced plunger, 5µL and 10µL 344<br />

Gas Tight Gas and liquid tight, 10µL to 100mL 345<br />

Autosampler Syringes compatible with many popular autosamplers 345<br />

Microvolume Plunger-in-needle, gas and liquid tight, 0.5µL to 5µL 346<br />

On-Column On-column capillary GC injection, 0.5µL to 10µL 346<br />

Popper Syringes<br />

Standard Glass General purpose, 2mL to 50mL 347<br />

syringes<br />

tech tips<br />

Tips for Syringe Use and Care<br />

Cleaning Needles—If your syringe needle becomes clogged, do<br />

not force liquid or compressed air through the syringe. Excessive<br />

pressure can cause the glass barrel of the syringe to split. To<br />

properly clean the needle, remove the plunger from the syringe.<br />

Use cleaning wires to dislodge any foreign material or residue<br />

build-up, and rinse the syringe thoroughly with deionized water or<br />

acetone. <strong>Grace</strong> offers a variety of syringe care products to help<br />

you maintain the performance of your syringe on page 347.<br />

Sterilizing Syringes—Chemical sterilizers are the best means for<br />

sterilizing your syringe. Be sure to thoroughly rinse your syringe<br />

after sterilization to remove all traces of the chemical solution. In<br />

general, autoclaving your syringe is not recommended. Stainless<br />

steel expands faster than the glass upon heating. Heating a<br />

syringe with a cemented, stainless steel needle may cause the<br />

glass barrel to split. Heating a syringe with cemented steel hubs<br />

may result in adhesive deterioration and leakage.<br />

Syringe Lubrication—A clean syringe does not require any<br />

lubricating grease. Grease may cause a variety problems such as<br />

sample cross contamination, seizing of the plunger in the barrel,<br />

and barrel damage or breakage.<br />

7245<br />

336 www.discoverysciences.com


general chromatography<br />

Hamilton ® Selection Guide<br />

Syringe Terminations<br />

N—Cemented (fixed) Needle, up to 250µL<br />

Point Styles<br />

Point Style AS:<br />

N and LTN syringes have needles<br />

cemented into the glass syringe<br />

barrel. Do not heat to more than<br />

50°C, do not autoclave, do not use<br />

with halogenated solvents such<br />

as methylene chloride. Choose<br />

a cemented needle if you want<br />

reproducible injections at an<br />

economical price.<br />

LTN—Cemented (fixed) Needle with Luer Tip,<br />

500µL and larger<br />

4790<br />

4792<br />

Point Style 2:<br />

Point Style 3:<br />

Point Style 4:<br />

2593<br />

2589<br />

2590<br />

Special conical needle designed to<br />

withstand the demands of multiple<br />

injections; exclusively used on<br />

autosampler syringes.<br />

Beveled non-coring needle<br />

recommended for septum penetration;<br />

only needle gauges 26s–22 are<br />

recommended for optimum GC<br />

septum penetration.<br />

Blunt needle for use with HPLC<br />

injection valves and for sample<br />

pipetting.<br />

LT—Luer Tip<br />

Ground glass male luer tip accepts<br />

most hypodermic needles. Use Kel-F ®<br />

hubs and connectors for a tight, leakfree<br />

seal. Choose LT syringes if you<br />

want an autoclavable syringe with<br />

easy, fast needle replacement.<br />

4791<br />

Point Style 5:<br />

2591<br />

2592<br />

10–12° beveled needle recommended<br />

for life science applications.<br />

Conical needle with side port for<br />

penetration of septa, thin-gauged<br />

vinyls and plastics without coring;<br />

minimizes septum damage.<br />

KH—Knurled Hub<br />

Metal knurled hub with removable<br />

needle, exclusive to 7000 Series<br />

syringes. It creates a leak-free seal<br />

between the barrel and the needle<br />

and can be tightened to compensate<br />

for wear. Autoclavable when<br />

disassembled.<br />

RN—Removable Needle<br />

Choose removable needles to easily<br />

replace bent or clogged needles or<br />

use different types of needles with<br />

the same syringe barrel. Autoclavable<br />

when disassembled.<br />

TLL—PTFE Luer Lock<br />

Male luer taper with nickel-plated<br />

brass hub that accepts and locks<br />

luer hub needles and connectors.<br />

Autoclavable when disassembled.<br />

Choose TLL syringes for fast needle<br />

replacement with a locking needle<br />

connection.<br />

4793<br />

4794<br />

4795<br />

Syringe Solution Reference Chart<br />

Hamilton has designed many unique syringes to address<br />

specific problems. Use the chart below to select the right<br />

syringe for the job.<br />

Syringe Problems and Solutions<br />

Problem Syringe Solution Hamilton ®<br />

Series<br />

Bending Plungers<br />

Use reinforced plunger<br />

syringes<br />

600, 800, 900,<br />

1800<br />

Breaking Syringe Barrels<br />

Bending Needles<br />

Use a Chaney adapter or<br />

syringe guide<br />

Use replaceable barrel<br />

syringes<br />

Use removable needle<br />

syringes<br />

700, 800, 900,<br />

1000, 1700,<br />

1800, 7000<br />

800, 1000, 1700,<br />

1800, 7000<br />

600, 700, 800,<br />

900, 1000, 1700,<br />

1800, 7000<br />

Syringe Balance Use syringe with handles 800, 900, 1800<br />

Plungers Pulling or<br />

Use pull or blow-out 800, 1800<br />

Blowing-out of Syringe Barrel prevention syringes<br />

Plungers Slide Too Easily Use adjustable plunger<br />

drag syringes<br />

800, 1800<br />

syringes<br />

www.discoverysciences.com<br />

337


general chromatography<br />

syringes<br />

Hamilton ® Syringes<br />

700 Series MICROLITER Syringes<br />

General Purpose Syringe,<br />

5µL to 500µL<br />

• Plungers are not<br />

interchangeable or replaceable<br />

• Accurate to 1% of the syringe volume<br />

Hamilton ® 700 Series Syringes<br />

Model Volume Gauge Pt. Style Repl. Needle Qty. Part No.<br />

Cemented Needle Syringes (N), 2" Needle Length<br />

75 5µL 26s 2 None ea 87900<br />

5µL 26s 3 None ea 87919<br />

701 10µL 26s 2 None ea 80300<br />

10µL 26s 3 None ea 803830<br />

10µL 26s 5 None ea 80339<br />

702 25µL 22s 2 None ea 80400<br />

25µL 22s 3 None ea 80465<br />

25µL 22s 5 None ea 80439<br />

705 50µL 22s 2 None ea 80500<br />

50µL 22s 3 None ea 80565<br />

50µL 22s 5 None ea 80539<br />

710 100µL 22s 2 None ea 80600<br />

100µL 22s 3 None ea 80665<br />

100µL 22s 5 None ea 80639<br />

725 250µL 22s 2 None ea 80700<br />

250µL 22s 3 None ea 80765<br />

250µL 22s 5 None ea 80739<br />

750 500µL 22 2 None ea 80800<br />

500µL 22 3 None ea 80865<br />

500µL 22 5 None ea 80839<br />

Removable Needle Syringes (RN), 2" Needle Length<br />

75 5µL 26s 2 7758-02 ea 87930<br />

701 10µL 26s 2 7758-02 ea 803300<br />

702 25µL 22s 2 7758-03 ea 80430<br />

705 50µL 22s 2 7758-03 ea 80530<br />

710 100µL 22s 2 7758-03 ea 80630<br />

725 250µL 22s 2 7779-03 ea 80730<br />

750 500µL 22 2 7779-01 ea 808301<br />

Luer Tip Syringes (LT)<br />

701 10µL — — * ea 80301<br />

702 25µL — — * ea 80401<br />

705 50µL — — * ea 80501<br />

710 100µL — — * ea 80601<br />

725 250µL — — * ea 80701<br />

750 500µL — — * ea 808011<br />

For Rheodyne ® , Valco ® VISF-2, Beckman ® /Altex and SSI, 2" Needle<br />

Length, Fixed Needle<br />

701 10µL 22s 3 None ea 80365<br />

702 25µL 22s 3 None ea 80465<br />

705 50µL 22s 3 None ea 80565<br />

710 100µL 22s 3 None ea 80665<br />

725 250µL 22 3 None ea 80765<br />

750 500µL 22 3 None ea 80865<br />

*Order needles separately, see page 342.<br />

4801<br />

Guide<br />

Plunger Guides reduce the<br />

expense of replacing or<br />

repairing syringes with bent<br />

plungers. They are especially<br />

useful on syringes with small<br />

diameter plungers.<br />

Chaney Adapter<br />

Chaney Adapters ensure<br />

consistent sample delivery.<br />

You will know the sample size<br />

is right every time.<br />

Guides and Chaney Adapters<br />

Description<br />

Part No.<br />

Guide for 701 14806<br />

Guide for 702–750, 7000 14906<br />

Chaney Adapter for 701, 75 147000<br />

Chaney Adapter for 702–750 and 7000 14725<br />

900 Series MICROLITER Syringes<br />

• Low price with<br />

a reinforced<br />

construction<br />

600 Series MICROLITER Syringes<br />

• Suitable for<br />

Rheodyne ® ,<br />

Beckman ® /Altex, and<br />

Valco ® VISF-2<br />

Reinforced<br />

Plunger<br />

Hamilton ® 900 Series Syringes<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

Cemented Needle Syringes (N), 2" Needle Length<br />

95 5µL 26s 2 None 87920<br />

901 10µL 26s 2 None 803600<br />

Removable Needle Syringes (RN), 2" Needle Length<br />

95 5µL 26s 2 7758-02 87925<br />

901 10µL 26s 2 7758-02 803700<br />

4800<br />

4799<br />

4808<br />

Save Money on Model 701 with Multi-Packs<br />

• Economical—syringes cost less in six packs<br />

• Easy identification—six numbered dots<br />

provide quick syringe identification<br />

best<br />

value<br />

Hamilton ® 600 Series Syringes<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

Removable Needle Syringes (RN), 2" Needle Length<br />

62 2.5µL 22s 3 7770-01 87942<br />

65 5µL 22s 3 7770-01 87943<br />

4804<br />

Hamilton ® 700 Series Six-packs (2" Needle Length)<br />

Model Volume Gauge Pt. Style Repl. Needle Qty. Part No.<br />

Cemented Needle Syringes (N), 2" Needle Length<br />

701N 10µL 26s 2 None 6 80366<br />

701N 10µL 26s 2 None 12 803662<br />

701RN 10µL 26s 2 7758-02 6 80336<br />

338 www.discoverysciences.com<br />

4802


general chromatography<br />

Hamilton ® Syringes<br />

800 Series MICROLITER Syringes<br />

• General purpose<br />

syringe<br />

• Extended handle<br />

simplifies sampling<br />

from test tubes or<br />

long-necked flasks<br />

Reinforced<br />

Plunger<br />

1000 Series GASTIGHT Syringes<br />

Gas and Liquid Tight, 1mL to 100mL<br />

• PTFE-tipped plungers<br />

• Replaceable barrels and<br />

plungers<br />

Hamilton ® 800 Series Syringes<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

Cemented Needle Syringes (N), 2" Needle Length<br />

85 5µL 26s 2 None 84850<br />

801 10µL 26s 2 None 84852<br />

802 25µL 22s 2 None 84854<br />

805 50µL 22s 2 None 84856<br />

810 100µL 22s 2 None 84858<br />

Removable Needle Syringes (RN), 2" Needle Length<br />

85 5µL 26s 2 7758-02 84851<br />

801 10µL 26s 2 7758-02 84853<br />

802 25µL 22s 2 7758-03 84855<br />

805 50µL 22s 2 7758-03 84857<br />

810 100µL 22s 2 7758-03 84859<br />

825 250µL 22s 2 7758-03 84861<br />

Removable Needle Syringes (RNW)<br />

For Waters ® U6K Injection Valve, 1.97" Needle Length<br />

801 10µL 25s 3 80426 84815<br />

802 25µL 25s 3 80426 84816<br />

805 50µL 25s 3 80426 84817<br />

810 100µL 25s 3 80426 84818<br />

825 250µL 25s 3 80726 84819<br />

7000 Series MODIFIED MICROLITER <br />

Syringes<br />

Plunger-in-Needle Design,<br />

0.5µL to 5µL<br />

• No dead volume<br />

• Replaceable barrels and<br />

plunger wires<br />

• Not recommended for viscous samples<br />

Hamilton ® 7000 Series Syringes<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

Knurled Hub Syringes (KH), 2.75" Needle Length<br />

7000.5 0.5µL 25 2 17887 86259<br />

0.5µL 25 3 17187 86250<br />

7000.50C* 0.5µL 32 3 86258 86257<br />

7001 1µL 25s 2 17886 80135<br />

1µL 25s 3 17188 80100<br />

7101 1µL 22s 2 17890 86211<br />

1µL 22s 3 17190 86200<br />

7002 2µL 25 2 17891 88411<br />

2µL 25 3 17191 88400<br />

7102 2µL 23 2 17892 88511<br />

2µL 23 3 17192 88500<br />

7105 5µL 24 2 17893 88011<br />

5µL 24 3 17193 88000<br />

*Needle length = 3.94" (2cm).<br />

4805<br />

best<br />

seller<br />

4803<br />

Hamilton ® 1000 Series Syringes<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

Removable Needle Syringes (RN), 2" Needle Length<br />

1001 1.0mL 22 2 7779-01 81330<br />

1002 2.5mL 22 2 7779-01 81430<br />

1005 5.0mL 22 2 7779-01 81530<br />

1010 10.0mL 22 2 7779-01 81630<br />

Luer Tip Syringes (LT), 2" Needle Length<br />

1001 1.0mL — — ** 81301<br />

1002 2.5mL — — ** 81401<br />

1005 5.0mL — — ** 81501<br />

1010 10.0mL — — ** 81601<br />

Luer Tip w/Cemented Needle Syringes (LTN), 2" Needle Length<br />

1001 1.0mL 22 2 None 81317<br />

1.0mL 22 5 None 81343<br />

1002 2.5mL 22 2 None 81417<br />

2.5mL 22 5 None 81443<br />

1005 5.0mL 22 2 None 81517<br />

5.0mL 22 5 None 81543<br />

1010 10.0mL 22 2 None 81617<br />

10.0mL 22 5 None 81643<br />

PTFE Luer Lock Syringes (TLL), 2" Needle Length<br />

1001 1.0mL — — ** 81320<br />

1002 2.5mL — — ** 81420<br />

1005 5.0mL — — ** 81520<br />

1010 10.0mL — — ** 81620<br />

1025 25.0mL — — ** 82520<br />

1050 50.0mL — — ** 85020<br />

1100 100.0mL — — ** 86020<br />

Removable Needle Syringes, 0.75" Needle Length<br />

For Valco ® (VISF-1) Injection Valves — Black<br />

1001 1mL 22 3 76515 81331<br />

1002 2.5mL 22 3 76515 81431<br />

1005 5mL 22 3 76515 81531<br />

1010 10mL 22 3 76515 81631<br />

For Rheodyne ® , Valco ® (VISF-2), Beckman ® /Altex, and SSI — Black<br />

1001 1mL 22 3 7780-04 81365<br />

Luer Tip w/Cemented Needle Syringes (LTN), 2" Needle Length For<br />

Rheodyne ® , Valco ® (VISF-2), Beckman ® /Altex, and Black SSI<br />

1001 1.0mL 22 3 None 81316<br />

1002 2.5mL 22 3 None 81416<br />

1005 5.0mL 22 3 None 81516<br />

1010 10.0mL 22 3 None 81616<br />

**Order needles separately, see page 342.<br />

4809<br />

syringes<br />

Guides and Chaney Adapters<br />

Syringe Model<br />

Part No.<br />

Guide Assembly for 7000 Series 14906<br />

Chaney Adapter for 7000 Series 14725<br />

www.discoverysciences.com<br />

339


general chromatography<br />

syringes<br />

Hamilton ® Syringes<br />

1700 Series GASTIGHT Syringes<br />

Gas and Liquid Tight, 10µL to 500µL<br />

• PTFE-tipped plungers<br />

• Replaceable barrels and<br />

plungers<br />

Hamilton ® 1700 Series GASTIGHT Syringes<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

Cemented Needle Syringes (N), 2" Needle Length<br />

1701 10µL 26s 2 None 80000<br />

10µL 26s 3 None 800750<br />

10µL 26 3 None 800850<br />

10µL 26 5 None 80039<br />

1702 25µL 22s 2 None 80200<br />

25µL 22s 3 None 802750<br />

25µL 22s 5 None 80239<br />

25µL 22 3 None 80285<br />

1705 50µL 22s 2 None 80900<br />

50µL 22s 3 None 80975<br />

50µL 22s 5 None 80939<br />

50µL 22 3 None 80985<br />

1710 100µL 22s 2 None 81000<br />

100µL 22s 3 None 81075<br />

100µL 22s 5 None 81039<br />

100µL 22 3 None 81085<br />

1725 250µL 22s 2 None 81100<br />

250µL 22s 3 None 81175<br />

250µL 22s 5 None 81139<br />

250µL 22 3 None 81185<br />

Removable Needle Syringes (RN), 2" Needle Length<br />

1701 10µL 26s 2 7758-02 800300<br />

1702 25µL 22s 2 7758-03 80230<br />

1705 50µL 22s 2 7758-03 80930<br />

1710 100µL 22s 2 7758-03 81030<br />

1725 250µL 22s 2 7779-03 81130<br />

1750 500µL 22 2 7779-01 81230<br />

Luer Tip Syringes (LT)<br />

1701 10µL — — * 80001<br />

1702 25µL — — * 80201<br />

1705 50µL — — * 80901<br />

1710 100µL — — * 81001<br />

1725 250µL — — * 81101<br />

1750 500µL — — * 81201<br />

Luer Tip with Cemented Needle Syringes (LTN), 2" Needle Length<br />

1750 500µL 22 2 None 81217<br />

500µL 22 3 None 81216<br />

500µL 22 5 None 81243<br />

PTFE Luer Lock Syringes (TLL) / Without Slots<br />

1705 50µL — — * 80920<br />

1710 100µL — — * 81020<br />

1725 250µL — — * 81120<br />

1750 500µL — — * 81220<br />

*Order needles separately, see page 342.<br />

Hamilton ® 1700 Series GASTIGHT Syringes<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

Removable Needle Syringes<br />

For Waters ® U6K Injection Valve (RNW), 1.97" Needle Length<br />

1702 25µL 25s 3 80426 80238<br />

1705 50µL 25s 3 80426 80938<br />

1710 100µL 25s 3 80426 81038<br />

1725 250µL 25s 3 80726 81138<br />

For Rheodyne ® , Valco ® VISF-2, Beckman ® /Altex, SSI (RNR),<br />

2" Needle Length<br />

1701 10µL 22s 3 7770-01 80065<br />

1702 25µL 22s 3 7770-01 80265<br />

4780<br />

Hamilton ® 1700 Series GASTIGHT Syringes (continued)<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

For Rheodyne ® , Valco ® VISF-2, Beckman ® /Altex, SSI (RNR),<br />

2" Needle Length (continued)<br />

1705 50µL 22s 3 7770-01 80965<br />

1710 100µL 22s 3 7770-01 81065<br />

1725 250µL 22 3 7780-04 81165<br />

1750 500µL 22 3 7780-04 81265<br />

For Valco ® VISF-1 (RNCP), 0.75" Needle Length<br />

1702 25µL 22s 3 76517 80231<br />

1705 50µL 22s 3 76517 80931<br />

1710 100µL 22s 3 76517 81031<br />

1725 250µL 22s 3 76517 81131<br />

1750 500µL 22 3 76515 81231<br />

1800 Series GASTIGHT Syringes<br />

Gas and Liquid Tight with Reinforced Plunger,<br />

10µL to 250µL<br />

• Similar to the 1700 Series<br />

Reinforced<br />

but with a reinforced,<br />

Plunger<br />

protected plunger<br />

• PTFE-tipped plungers<br />

• Replaceable barrels and plungers<br />

Hamilton ® 1800 Series Syringes and Accessories<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

Cemented Needle Syringes (N), 2" Needle Length<br />

1801 10µL 26s 2 None 84875<br />

1802 25µL 22s 2 None 84878<br />

1805 50µL 22s 2 None 84881<br />

1810 100µL 22s 2 None 84884<br />

1825 250µL 22s 2 None 84887<br />

Removable Needle Syringes (RN), 2" Needle Length<br />

1801 10µL 26s 2 7758-02 84877<br />

1802 25µL 22s 2 7758-03 84880<br />

1805 50µL 22s 2 7758-03 84883<br />

1810 100µL 22s 2 7758-03 84886<br />

1825 250µL 22s 2 7779-03 84889<br />

Removable Needle Syringes (RNW)<br />

For Waters ® U6K Injection Valve, 1.97" Needle Length<br />

1802 25µL 25s 3 80426 84980<br />

1805 50µL 25s 3 80426 84983<br />

1810 100µL 25s 3 80426 84986<br />

1825 250µL 25s 3 80726 84989<br />

Hamilton Accessories<br />

Chaney Adapter for 801-825, 1801-1825 32146<br />

Super Gas Syringes<br />

Gas Tight, Large Volume<br />

Syringes, 500mL to 2000mL<br />

• Ideal for air and gas sampling<br />

• Graduated every 20mL<br />

• Acrylic barrels with PTFE-coated<br />

aluminum pistons<br />

Hamilton ® Super Gas Syringes<br />

Model Volume Part No.<br />

Syringe with PTFE Luer Lock (TLL)<br />

S-0500 0.5 Liter 86311<br />

S-1000 1.0 Liter 86312<br />

S-1500 1.5 Liter 86313<br />

S-2000 2.0 Liter 86314<br />

4781<br />

4783<br />

340 www.discoverysciences.com


general chromatography<br />

Hamilton ® Syringes<br />

Autosampler Syringes<br />

For the Agilent 7673 and 7683 Autosamplers<br />

• Standard needle length is 1.71"<br />

Syringes for the Agilent 7673 and 7683 Autosamplers<br />

Model Volume Gauge Pt. Style Qty. Part No.<br />

Cemented Needle Syringes (ASN)<br />

75 5µL 23s AS ea 87987<br />

5µL 23s AS 6 87990<br />

5µL 23s 2 ea 87991<br />

5µL 26s AS ea 87988<br />

5µL 26s AS 6 87989<br />

5µL 26s 2 ea 87992<br />

5µL 23s-26s AS ea 87993<br />

5µL 23s-26s AS 6 87994<br />

701 10µL 23s AS ea 803871<br />

10µL 23s AS 6 803901<br />

10µL 23s 2 ea 80398<br />

10µL 26s AS ea 803881<br />

10µL 26s AS 6 803891<br />

10µL 26s 2 ea 80399<br />

10µL 23s-26s AS ea 80393<br />

10µL 23s-26s AS 6 803911<br />

Removable Needle Syringes (ASRN)<br />

75 5µL 23s AS ea 87957<br />

5µL 26s AS ea 87958<br />

5µL 23s-26s AS ea 87959<br />

701 10µL 23s AS ea 80357<br />

10µL 26s AS ea 80358<br />

10µL 23s-26s AS ea 80359<br />

Cemented Needle Gastight Syringes (ASN)<br />

175 5µL 23s AS ea 800741<br />

5µL 23s AS 6 80090<br />

5µL 23s-26s AS ea 800761<br />

5µL 23s-26s AS 6 80092<br />

1701 10µL 23s AS ea 800801<br />

10µL 23s AS 6 80094<br />

10µL 23s-26s AS ea 800791<br />

10µL 23s-26s AS 6 80096<br />

Removable Needle Gastight Syringes (ASRN)<br />

175 5µL 23s-26s AS ea 80086<br />

1701 10µL 23s AS ea 80087<br />

10µL 23s-26s AS ea 80089<br />

For the Agilent 7670, 7671, and 7672<br />

Autosamplers<br />

Syringes for Agilent 7670, 7671, 7672 Autosamplers<br />

Model Volume Gauge Pt. Style Qty. Part No.<br />

Cemented Needle Syringes (N), 2" Needle<br />

701N 10µL 26s 2 ea 80300<br />

10µL 26s 2 6 80366<br />

Removable Needle Syringes (RN), 2" Needle<br />

701 10µL 26s 2 ea 80338<br />

Cemented Needle with PTFE-Tipped Plungers (N), 2" Needle<br />

1701 10µL 26s 2 ea 80000<br />

Removable Needle with PTFE-Tipped Plungers (RN), 2" Needle<br />

1701 10µL 26s 2 ea 800110<br />

For the PerkinElmer ® Autosystem<br />

Syringes for the PerkinElmer ® Autosystem<br />

Model Volume Needle o.d. Needle Lgth. Pt. Style Part No.<br />

Cemented Needle Syringes (ASN/PE)<br />

75 5µL 0.47mm 2.756" 3 880401<br />

5µL 0.63mm 2.756" 3 880351<br />

SampleLock Syringes<br />

• 1000 and 1700 Series<br />

syringes with twist valve<br />

Hamilton ® SampleLock Syringes<br />

Model Volume Gauge Pt. Style Repl. Needle Part No.<br />

SampleLock Syringes, 2" Needle Length<br />

1705 50µL 22s 2 7779-03 80956<br />

1710 100µL 22s 2 7779-03 81056<br />

1725 250µL 22s 2 7779-03 81156<br />

1750 500µL 22 2 7779-01 812560<br />

1001 1mL 22 2 7779-01 81356<br />

1002 2.5mL 22 2 7779-01 81456<br />

1005 5mL 22 2 7779-01 81556<br />

1010 10mL 22 2 7779-01 81656<br />

1025 25mL 22 2 7779-01 863260<br />

1050 50mL 22 2 7779-01 863360<br />

1100 100mL 22 2 7779-01 86346<br />

6611<br />

Replacement Needles for Agilent Autosamplers<br />

• For 5 and 10µL syringes<br />

Agilent Autosampler Replacement Needles<br />

Gauge Needle Length Pt. Style Qty. Part No.<br />

23s-26s 1.71" AS 6 7785-01<br />

23s 1.71" AS 6 7786-01<br />

26s 1.71" AS 6 7786-02<br />

Valves and Adapters<br />

syringes<br />

For the Waters ® WISP Autosampler<br />

Syringes for the Waters ® WISP Autosampler<br />

Model Volume Part No.<br />

Gastight Syringes with PTFE-Tipped Plungers<br />

1725 WISP 250µL 80024<br />

more info<br />

See page 195 for Hamilton ® TLC Syringes.<br />

4812 4811 4810<br />

Valves and Adapters<br />

Description Qty. Part No.<br />

Sampling Valve<br />

Inert Gas Sampling Valve 86580<br />

Luer Adapters<br />

Female Luer to Removable Needle Hub 35081<br />

Male Luer to Removable Needle Hub 35080<br />

Male Luer Lock to Removable Needle Hub 35083<br />

Septum Adapter<br />

Septum Adapter (TLL), Includes 12 Septa ea 313350<br />

Replacement Septa, 7mm 12 75810<br />

www.discoverysciences.com<br />

341


general chromatography<br />

syringes<br />

Hamilton ® Needles<br />

RN Replacement Needle Packs<br />

• For syringes designated “RN”<br />

• Needle length is 2"<br />

RN Replacement Needles<br />

5-100μL<br />

Part No.<br />

250μL-10mL<br />

Part No.<br />

Gauge Pt. Style Qty.<br />

RN Needles for 5µL — 100µL Syringes<br />

22 2 6 7758-01 7779-01<br />

22 3* 6 7770-02 7780-04<br />

22 5 6 7784-06 7784-04<br />

22s 2 6 7758-03 7779-03<br />

22s 3* 6 7770-01 7780-03<br />

22s 5 6 7784-05 7784-03<br />

26 2 6 7758-04 7779-04<br />

26 3 6 7768-02 7780-02<br />

26 5 6 7784-08 7784-02<br />

26s 2 6 7758-02 7779-02<br />

26s 3 6 7768-01 7780-01<br />

26s 5 6 7784-07 7784-01<br />

*Compatible with Rheodyne ® Valves.<br />

Replacement Needles for HPLC Syringes<br />

HPLC Replacement Needles<br />

Gauge Length Pt. Style For Valve Qty. Part No.<br />

RN Needles for 5µL — 100µL Syringes<br />

22s 0.75" 3** Valco ® 6 7787-01<br />

22s 2" 3* Rheodyne ® 6 7770-01<br />

25s 1.97" 3*** Waters ® 6 8647-01<br />

RN Needles for 250µL — 10mL Syringes<br />

22 0.75" 3** Valco ® 6 7787-02<br />

22 2" 3* Rheodyne ® 6 7780-04<br />

22s 0.75" 3** Valco ® 3 76518<br />

22s 2" 3* Rheodyne ® 6 7780-03<br />

25s 1.97" 3*** Waters ® 6 8648-01<br />

CTFE Luer Hub Needles<br />

22 2" 3* Rheodyne ® 6 90536<br />

22s 2" 3* Rheodyne ® 6 90534<br />

*Compatible with Rheodyne ® , Beckman ® /Altex, SSI, and Valco ® Model VISF-2 Valves;<br />

**Compatible with Valco ® Valves; ***Compatible with Waters ® Valves.<br />

tech tip<br />

Needle Gauge vs. o.d.-i.d.<br />

Gauge o.d. i.d.<br />

33 0.008" 0.2032mm 0.004" 0.1016mm<br />

32 0.009" 0.2286mm 0.004" 0.1016mm<br />

31 0.010" 0.2540mm 0.005" 0.1270mm<br />

30 0.012" 0.3048mm 0.006" 0.1524mm<br />

29 0.013" 0.3302mm 0.007" 0.1778mm<br />

28 0.014" 0.3556mm 0.005" 0.1270mm<br />

27 0.016" 0.4064mm 0.008" 0.2032mm<br />

26s 0.0185" 0.4699mm 0.0045" 0.1143mm<br />

26 0.018" 0.4572mm 0.010" 0.2540mm<br />

25 0.020" 0.5080mm 0.010" 0.2540mm<br />

24 0.022" 0.5588mm 0.012" 0.3048mm<br />

23 0.025" 0.6350mm 0.013" 0.3302mm<br />

22 0.028" 0.7112mm 0.016" 0.4064mm<br />

22s 0.028" 0.7112mm 0.006" 0.1524mm<br />

21 0.032" 0.8128mm 0.020" 0.5080mm<br />

20 0.035" 0.8890mm 0.023" 0.5842mm<br />

19 0.042" 1.0668mm 0.027" 0.6858mm<br />

18 0.049" 1.2446mm 0.033" 0.8382mm<br />

17 0.058" 1.4732mm 0.042" 1.0668mm<br />

16 0.065" 1.6510mm 0.047" 1.1938mm<br />

15 0.077" 1.9558mm 0.054" 1.3716mm<br />

Standard Luer Hub Needles<br />

• Will fit any luer or luer lock hub<br />

• Needle length is 2"<br />

• All needles are 304 SS<br />

Metal Luer Needles<br />

• Economical<br />

Metal Hub<br />

Kel-F Hub<br />

Standard Luer Hub Needles<br />

Needle Metal Hub Kel-F ® Hub<br />

Gauge Pt. Style Qty. Part No. Part No.<br />

16 2 6 N-716 KF-716<br />

16 3 6 91016 90516<br />

16 5 6 7729-12 7746-01<br />

17 2 6 N-717 KF-717<br />

17 3 6 910170 90517<br />

17 5 6 7729-11 7746-02<br />

18 2 6 N-718 KF-718<br />

18 3 6 910180 90535<br />

18 5 6 7729-10 7746-03<br />

20 2 6 N-720 KF-720<br />

20 3 6 910200 905200<br />

20 5 6 7729-09 7746-04<br />

21 2 6 N-721 KF-721<br />

21 3 6 910210 90521<br />

21 5 6 7729-08 7746-05<br />

22 2 6 N-722 KF-722<br />

22 3* 6 91022 90536<br />

22 5 6 7729-07 7746-06<br />

22s 2 6 N-722s KF-722s<br />

22s 3* 6 910380 90534<br />

22s 5 6 7729-02 7746-11<br />

23 2 6 N-723 KF-723<br />

23 3 6 910230 90523<br />

23 5 6 7729-06 7746-07<br />

24 2 6 N-724 KF-724<br />

24 3 6 91024 90524<br />

24 5 6 7729-05 7746-08<br />

25 2 6 N-725 KF-725<br />

25 3 6 910250 90525<br />

25 5 6 7729-04 7746-09<br />

26 2 6 N-726 KF-726<br />

26 3 6 91026 90533<br />

26 5 6 7729-03 7746-10<br />

26s 2 6 N-726s KF-726s<br />

26s 5 6 7729-01 7746-12<br />

*Compatible with Rheodyne ® Valves.<br />

Metal Luer Needles<br />

Description Gauge Length Qty. Part No.<br />

Beveled Point<br />

Metal Luer 18 1.5" 12 90096<br />

Metal Luer 22 1.5" 12 90100<br />

more info<br />

For more replacement parts for<br />

Hamilton ® Syringes, please visit<br />

our website.<br />

4797<br />

4798<br />

5048<br />

342<br />

www.discoverysciences.com


general chromatography<br />

Vici ® Precision Syringes<br />

Point Styles<br />

Point Style 2<br />

2645<br />

VICI ® Precision<br />

Replacement Parts<br />

Replacement Plunger Tips and Needles<br />

Gas Syringe Features<br />

Pressure Removable Luer Valve Plunger<br />

Series Rating Needle Needle Type Stop<br />

A 250psig X Twist-Lock X<br />

A-2 250psig X X Push-Button X<br />

Series A Syringes<br />

Gas Tight with a Twist Valve, 100µL to 10mL<br />

• PTFE-tipped plunger and<br />

needle seal<br />

• Twist valve stores sample in barrel<br />

Series A Syringes<br />

Volume Ndl. o.d. Pt. Style Repl. Needle Part. No.<br />

Removable Needle Syringes, 2.25" Needle Length<br />

100µL 0.029" 2 913050 010025<br />

250µL 0.029" 2 913050 010031<br />

500µL 0.029" 2 913050 010032<br />

1mL 0.029" 2 913050 010033<br />

2mL 0.029" 2 913050 010034<br />

5mL 0.029" 2 913050 010035<br />

10mL 0.029" 2 913050 010036<br />

5041<br />

Replacement PTFE Plunger Tips<br />

Description<br />

Part No.<br />

For Series A and A-2 Syringes<br />

100µL 16192<br />

250µL 16194<br />

500µL 013932<br />

1mL 013933<br />

2mL 013934<br />

5mL 013935<br />

10mL 013936<br />

Replacement Needles 3/pk<br />

Fit Models Ndl. o.d. Ndl. i.d. Ndl. Lgth. Pt. Style Part. No.<br />

Removable Needles<br />

A 0.029" 0.012" 2.25" 2 913050<br />

0.029" 0.012" 2.25" 3 913052<br />

A-2 0.028" 0.005" 2" 2 943050<br />

0.029" 0.012" 2" 2 943051<br />

0.029" 0.012" 2" 3 943052<br />

Luer Needles<br />

A-2 0.028" 0.006" 2" 2 943060<br />

0.028" 0.016" 2" 2 943061<br />

0.028" 0.016" 2" 3 943062<br />

Series A-2 Syringes<br />

Gas Tight with a Push Valve, 25µL to 10mL<br />

• PTFE-tipped plunger and<br />

needle seal<br />

• Push-button valve stores<br />

sample in barrel<br />

Series A-2 Syringes<br />

Volume Needle o.d. Pt. Style Repl. Needle Part. No.<br />

Removable Needle Syringes, 2" Needle Length<br />

25µL 0.028" 2 943050 050023<br />

50µL 0.028" 2 943050 050024<br />

100µL 0.028" 2 943050 050025<br />

250µL 0.029" 2 943051 050031<br />

500µL 0.029" 2 943051 050032<br />

1mL 0.029" 2 943051 050033<br />

2mL 0.029" 2 943051 050034<br />

5mL 0.029" 2 943051 050035<br />

10mL 0.029" 2 943051 050036<br />

Luer Syringes — Needle Supplied, 2" Needle Length<br />

25µL 0.028" 2 943060 16014<br />

50µL 0.028" 2 943060 16016<br />

100µL 0.028" 2 943060 16018<br />

250µL 0.028" 2 943061 16023<br />

500µL 0.028" 2 943061 16025<br />

1mL 0.028" 2 943061 16027<br />

2mL 0.028" 2 943061 16029<br />

5mL 0.028" 2 943061 16032<br />

10mL 0.028" 2 943061 16034<br />

best<br />

seller<br />

5040<br />

Mininert ® Syringe Valves<br />

• Add storage capability to standard<br />

syringes<br />

Mininert ® Valves<br />

Description<br />

Part No.<br />

To Fit Any Standard Luer Tip Syringes 654051<br />

more info<br />

For our full VICI ® Precision offering, including replacement<br />

parts and other syringes not listed here, visit the product portion<br />

of our website.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

5045<br />

syringes<br />

www.discoverysciences.com<br />

343


general chromatography<br />

syringes<br />

SGE ® Syringes<br />

Point Styles<br />

Point Style 1<br />

Point Style 2<br />

Point Style 3<br />

1503<br />

1504<br />

1505<br />

Plunger Protection Syringes<br />

#1 Cone Needle Tip – Designed<br />

for autosamplers. Recommended<br />

for use with pre-drilled septa.<br />

#2 20° Bevel Needle Tip – Standard general<br />

purpose needle.<br />

#3 HPLC Needle Tip – 90° square cut with<br />

chamfered and polished edges. Use with<br />

HPLC valves.<br />

General Purpose Syringes with Reinforced Plunger,<br />

5µL and 10µL<br />

• Includes certificate of conformance to NIST<br />

SGE ® Plunger Protection Syringes<br />

Volume Gauge Length Pt. Style Repl. Needle Qty. Part No.<br />

Fixed Needle Syringes<br />

5µL 26 5cm 2 None ea 85184<br />

10µL 26 5cm 2 None ea 85056<br />

10µL 26 5cm 2 None 6 85190<br />

10µL 26 5cm 2 None 10 85400<br />

Removable Needle Syringes<br />

5µL 26 5cm 2 85272 ea 85186<br />

10µL 26 5cm 2 85294 ea 85050<br />

10µL 26 5cm 2 85294 6 85194<br />

Standard Syringes<br />

General Purpose Syringes, 5µL and 10µL<br />

• Includes certificate of conformance to NIST<br />

SGE ® Standard Syringes<br />

Volume Gauge Length Pt. Style Repl. Needle Qty. Part No.<br />

Fixed Needle Syringes for Use with Merlin Microseal ®<br />

5µL 23 4.2cm 1 None ea 85005<br />

10µL 23 4.2cm 1 None ea 85003<br />

Fixed Needle Syringes<br />

25µL 25 5cm 2 None ea 85058<br />

50µL 25 5cm 2 None ea 85002<br />

100µL 25 5cm 2 None ea 85012<br />

250µL 25 5cm 2 None ea 85060<br />

500µL 25 5cm 2 None ea 85062<br />

Removable Needle Syringes<br />

25µL 25 5cm 2 85274 ea 85164<br />

50µL 25 5cm 2 85274 ea 85008<br />

100µL 25 5cm 2 85274 ea 85006<br />

250µL 25 5cm 2 85274 ea 85052<br />

500µL 25 5cm 2 85274 ea 85054<br />

more info<br />

For our full SGE ® offering, visit the product portion of our website.<br />

SuperfleX Syringes<br />

Syringes with Flexible Plungers, 5µL and 10µL<br />

• Includes plunger protection guide<br />

SGE ® SuperfleX Syringes<br />

Volume Gauge Length Pt. Style Repl. Needle Qty. Part No.<br />

Fixed Needle Syringes<br />

5µL 26 5cm 2 None ea 85196<br />

10µL 26 5cm 2 None ea 85206<br />

10µL 26 5cm 2 None 6 85208<br />

10µL 26 7cm 2 None ea 85185<br />

Removable Needle Syringes<br />

5µL 26 5cm 2 85272 ea 85200<br />

10µL 26 5cm 2 85294 ea 85210<br />

10µL 26 5cm 2 85294 6 85212<br />

NIST Syringes<br />

NIST and NBS Traceable,<br />

5µL to 500µL<br />

• Includes certificate<br />

of calibration<br />

SGE ® Factory Calibrated Syringes<br />

Volume Gauge Length Pt. Style Repl. Needle Part No.<br />

Fixed Needle Syringes with Repeating Adapter<br />

5µL 26 5cm 2 None 85015<br />

10µL 26 5cm 2 None 85017<br />

25µL 22 5cm 3 None 85023<br />

50µL 25 5cm 2 None 85025<br />

100µL 25 5cm 2 None 85027<br />

Guided Plunger Syringes<br />

Extended Barrel Syringes, 5µL and 10µL<br />

• Reinforced plunger<br />

SGE ® Guided Plunger Syringes<br />

Volume Gauge Length Pt. Style Repl. Needle Part No.<br />

Fixed Needle Syringes<br />

5µL 26 5cm 2 None 85022<br />

10µL 26 5cm 2 None 85038<br />

Removable Needle Syringes<br />

5µL 26 5cm 2 85272 85016<br />

10µL 26 5cm 2 85294 85018<br />

10µL 26 7cm 2 85163 85159<br />

4913<br />

4905<br />

4901<br />

344 www.discoverysciences.com


general chromatography<br />

SGE ® Syringes<br />

Gas Tight Syringes<br />

Gas and Liquid Tight,<br />

10µL to 100mL<br />

• Replaceable PTFE-tipped plunger<br />

best<br />

seller<br />

Autosampler Syringes<br />

4907<br />

SGE ® Gas Tight Syringes (Needles sold separately, see page 346)<br />

Volume Needle o.d. Length Pt. Style Part No.<br />

Fixed Luer Lock<br />

50µL — — — 85357<br />

100µL — — — 85359<br />

250µL — — — 85361<br />

500µL — — — 85363<br />

1mL — — — 85080<br />

2.5mL — — — 85123<br />

Removable Luer Lock<br />

5mL — — — 85088<br />

10mL — — — 85092<br />

25mL — — — 85125<br />

50mL — — — 85096<br />

100mL — — — 85098<br />

Luer Lock with Valve<br />

1mL — — — 85127<br />

2.5mL — — — 85131<br />

5mL — — — 85133<br />

10mL — — — 85135<br />

20mL — — — 85137<br />

50mL — — — 85139<br />

100mL — — — 85143<br />

SGE ® Gas Tight Syringes, Needles included<br />

Volume Gauge Length Pt. Style Repl. Needle Part No.<br />

Fixed Needle<br />

10µL 26 5cm 2 None 85064<br />

10µL 26 7cm 2 None 85066<br />

25µL 25 5cm 2 None 85321<br />

50µL 25 5cm 2 None 85323<br />

100µL 25 5cm 2 None 85325<br />

250µL 25 5cm 2 None 85327<br />

500µL 25 5cm 2 None 85329<br />

Removable Needle<br />

10µL 26 5cm 2 85294 85004<br />

25µL 25 5cm 2 85274 85331<br />

50µL 25 5cm 2 85274 85070<br />

100µL 25 5cm 2 85274 85072<br />

250µL 25 5cm 2 85274 85074<br />

500µL 25 5cm 2 85274 85076<br />

1mL 23 5cm 2 85276 85078<br />

2.5mL 23 5cm 2 85276 85117<br />

5mL 23 5cm 2 85278 85086<br />

10mL 23 5cm 2 85278 85090<br />

4905<br />

SGE ® Autosampler Syringes<br />

Volume Gauge Pt. Style Repl. Needle Qty. Part No.<br />

for Agilent 7673 Autosamplers<br />

Fixed Needle<br />

5µL 23 1 None ea 85014<br />

5µL 23 1 None 6 85140<br />

5µL 26 1 None ea 85136<br />

5µL 26 1 None 6 85138<br />

10µL 23 1 None ea 85144<br />

10µL 23 1 None 6 85036<br />

10µL 26 1 None ea 85142<br />

10µL 26 1 None 6 85034<br />

Removable Needle<br />

0.5µL 23 1 85292 ea 85134<br />

0.5µL 26 1 85262 ea 85132<br />

5µL 23 1 85298 ea 85248<br />

5µL 26 1 85296 ea 85394<br />

10µL 23 1 85302 ea 85148<br />

10µL 26 1 85300 ea 85146<br />

25µL 23 1 85040 ea 85047<br />

50µL 23 1 85040 ea 85416<br />

for PerkinElmer ® Autosystem<br />

Fixed Needle<br />

5µL 23 1 None ea 85069<br />

5µL 26 1 None ea 85067<br />

50µL 23 1 None ea 85419<br />

Gas Tight Fixed Needle<br />

5µL 23 1 None ea 85160<br />

5µL 26 1 None ea 85158<br />

Removable Needle<br />

0.5µL 23 1 85308 ea 85156<br />

0.5µL 26 1 85306 ea 85154<br />

for Shimadzu ® Autosamplers<br />

Models AOC14 and 17—Removable Needle<br />

0.5µL 26 1 85312 ea 85166<br />

10µL 26 1 85316 ea 85172<br />

for Varian ® Autosamplers<br />

Model 8000—Removable Needle<br />

10µL 25 5 85167 ea 85176<br />

Models 8035, 8100, 8200—Removable Needle<br />

10µL 25 5 85173 ea 85180<br />

for CTC/Fisons AS200 and AS800 Autosamplers<br />

Fixed Needle (50mm)<br />

10µL 26 1 None ea 85297<br />

25µL 26 1 None ea 85401<br />

Fixed Needle (80mm)<br />

10µL 26 1 None ea 85398<br />

Gas Tight Fixed Needle (50mm)<br />

10µL 23 1 None ea 85399<br />

25µL 23 1 None ea 85402<br />

syringes<br />

Repeating Adapters<br />

• Preset to any desired volume<br />

SGE ® Repeating Adapters<br />

Description<br />

Part No.<br />

RA-6 for 0.5, 5, 10µL Syringes 85263<br />

RA-8 for 25-500µL Syringes 85265<br />

4902<br />

www.discoverysciences.com<br />

345


general chromatography<br />

syringes<br />

SGE ® Syringes<br />

Micro Syringes<br />

• Plunger-in-needle, 0.5µL to 5µL<br />

• Liquid and gas tight to 650 atmospheres*<br />

SGE ® Microvolume Syringes<br />

Volume Gauge Length Pt. Style Repl. Needle/Plunger Part No.<br />

Standard Barrel — 8mm o.d.<br />

0.5µL 23 7cm 1 85266 85028<br />

0.5µL 23 7cm 2 85235 85209<br />

0.5µL 26 7cm 1 85237 85039<br />

1µL 23 5cm 1 85268 85000<br />

1µL 23 7cm 1 85284 85030<br />

1µL 23 7cm 2 85243 85211<br />

1µL 26 7cm 1 85245 85213<br />

5µL 23 5cm 1 85247 85215<br />

5µL 23 7cm 1 85270 85032<br />

5µL 23 7cm 2 85253 85217<br />

Standard Barrel with Repeating Adapter<br />

0.5µL 23 7cm 1 85266 85219<br />

1µL 23 5cm 1 85268 85223<br />

1µL 23 7cm 1 85284 85225<br />

1µL 26 7cm 1 85245 85227<br />

5µL 23 5cm 1 85247 85229<br />

5µL 23 7cm 1 85270 85231<br />

*Use a repeating adapter to prevent plunger blow-out at elevated pressures.<br />

HPLC Syringes<br />

• Syringes and needles sold separately<br />

SGE ® HPLC Syringes<br />

Volume Gauge Length Pt. Style Part No.<br />

Luer Lock Syringes<br />

1mL — — — 85080<br />

2.5mL — — — 85123<br />

5mL — — — 85088<br />

10mL — — — 85092<br />

25mL — — — 85125<br />

HPLC Injector Specific Luer Lock Needles (2/pk)<br />

For Rheodyne ® /Valco ® 22 2" 3 85151<br />

For Waters ® U6K 24 1.97" 3 85153<br />

On-Column Syringes<br />

• 0.5µL to 10µL<br />

5038<br />

best<br />

seller<br />

SGE ® On-Column Syringes<br />

Volume Needle o.d. Length Repl. Needle Part No.<br />

On-Column Syringes, Fused Silica Needles<br />

5µL 0.17mm 10cm 85365 85382<br />

10µL 0.17mm 10cm 85367 85384<br />

For 0.53mm i.d. Capillary Column, Stainless Steel Needles<br />

0.5µL 0.47mm 7cm 85237 85039<br />

1µL 0.47mm 7cm 85245 85213<br />

4911<br />

4910<br />

SGE ® Accessories<br />

Syringe Valves<br />

Model VLL<br />

5052<br />

Model VLL — Connect to any SGE ® removable needle<br />

syringe 25µL–2.5mL. Luer lock fitting cone with Kel-F ® core.<br />

Model VLLMA — Designed specifically for the SGE ® larger<br />

capacity luer lock syringes 5mL–100mL.<br />

Model SLLV — Can be fitted to any luer lock or luer tip<br />

syringe or device.<br />

Replacement Needles<br />

5053<br />

Model VLLMA<br />

Model SLLV<br />

SGE ® Retro-Fit Syringe Valves, Use Luer Hub Needles<br />

Description<br />

Part No.<br />

Model VLL 85043<br />

Model VLLMA 85049<br />

Model SVLL 85055<br />

SGE ® Replacement Needles<br />

SGE No. o.d. Needle Length Style Qty. Part No.<br />

For 5µL Syringes<br />

036110 0.47mm 5cm 2 5 85272<br />

036710 0.47mm 4.2cm 1 2 85296<br />

036720 0.63mm 4.2cm 1 2 85298<br />

For 10µL Syringes<br />

037011 0.63mm 5cm 1 2 85364<br />

037110 0.47mm 5cm 2 5 85294<br />

037715 0.47mm 4.2cm 1 2 85300<br />

037736 0.47mm 5cm 1 2 85197<br />

037745 0.47mm 5cm 1 2 85316<br />

037747 0.63mm 5cm 1 2 85334<br />

037785 0.47mm 5cm 1 2 85317<br />

For 25 – 500µL Syringes<br />

038110 0.5mm 5cm 2 5 85274<br />

038250 0.028" 2" 3 5 85332<br />

038260 0.5mm 5cm 3 5 85338<br />

038810 0.63mm 5cm 1 ea 85377<br />

For 1–2.5mL Syringes<br />

039110 0.63mm 5cm 2 5 85276<br />

For 5 –10mL Syringes<br />

031516 0.63mm 5cm 2 5 85278<br />

For Luer Lock and Luer Tip Syringes<br />

039802 0.63mm 5cm 2 5 85287<br />

039803 0.63mm 5cm 5 2 85145<br />

039822 1.07mm 5cm 2 5 85289<br />

039823 1.07mm 5cm 5 2 85147<br />

039862 1.67mm 5cm 2 5 85149<br />

039895 0.028" 2" 3 2 85151<br />

039897 0.5mm 5cm 3 2 85153<br />

On-Column Needles<br />

036675 0.23mm 7.5cm 1 2 85369<br />

036625 0.17mm 11cm 1 2 85373<br />

5054<br />

346 www.discoverysciences.com


general chromatography<br />

Popper Glass Syringes<br />

• All-glass plunger and barrel<br />

• Corrosion and heat resistant<br />

• Flat flanges prevent rolling<br />

• Needles sold separately<br />

Syringe Accessories<br />

Redi-Cut Fine Wires<br />

• Rust-proof stainless steel<br />

4670<br />

Interchangeable Glass Syringes<br />

Description Qty. Part No.<br />

Glass Male Luer Tip<br />

2cc Volume ea 3663<br />

5cc Volume ea 3972<br />

10cc Volume ea 3979<br />

20cc Volume ea 3984<br />

30cc Volume ea 3989<br />

50cc Volume ea 3991<br />

Metal Male Luer Lock<br />

2cc Volume ea 3393<br />

5cc Volume ea 3394<br />

10cc Volume ea 3395<br />

20cc Volume ea 3396<br />

30cc Volume ea 3369<br />

50cc Volume ea 3397<br />

5046<br />

Redi-Cut Fine Wires and Handle<br />

Description<br />

Part No.<br />

Redi-Cut Fine Wires, 10 each of diameters 0.003", 0.005", 4046<br />

0.010", 0.020"<br />

Handle 8184<br />

Syringe Cleaning Solutions<br />

• Syringe Kleen removes metal deposits<br />

from metal plungers<br />

• SK-2 soaking solution for hard-toremove<br />

silicones and organic residues<br />

Cleaning Solutions<br />

Description<br />

Part No.<br />

Syringe Kleen, 8oz 2030<br />

Syringe Kleen, 4 Bottles/pk 20304<br />

SK-2, 8oz 2040<br />

SK-2, 6 Bottles/pk 20406<br />

4671<br />

5047<br />

Needle Sharpener<br />

Serial Numbered Glass Syringes<br />

Description Qty. Part No.<br />

Glass Male Luer Tip<br />

2cc Volume ea 4687<br />

5cc Volume ea 4691<br />

10cc Volume ea 4693<br />

20cc Volume ea 4697<br />

50cc Volume ea 4707<br />

100cc Volume ea 4709<br />

Metal Male Luer Lock<br />

1cc Volume ea 4694<br />

2cc Volume ea 4696<br />

5cc Volume ea 4706<br />

10cc Volume ea 4708<br />

20cc Volume ea 4710<br />

50cc Volume ea 4714<br />

• Protect GC septa by<br />

sharpening needle in groove<br />

Needle Sharpener<br />

Description<br />

Part No.<br />

Needle Sharpener 2033<br />

Plastic Syringes<br />

• Use luer hub needles—sold<br />

separately (refer to page 342)<br />

4674<br />

syringes<br />

more info<br />

Use needles on page 342 with<br />

Popper Syringes.<br />

Plastic Syringes<br />

Description Qty. Part No.<br />

Plastic Syringes with a Luer Tip<br />

1mL Syringe 12 44701100<br />

5mL Syringe 12 447012<br />

20mL Syringe 2 447018<br />

4675<br />

4798<br />

www.discoverysciences.com<br />

347


general chromatography<br />

Vials Introduction<br />

Your sample, the type of vial, cap and septa, the solvent used, and the type of autosampler and detector all contribute to the end<br />

quality of your analysis. Choose from our wide selection of vial options to get the right vial for your analysis.<br />

Screw Thread<br />

Standard Mouth<br />

Wide Mouth<br />

R.A.M.— for Robotics<br />

Clear or Amber<br />

Clear or Amber<br />

Clear or Amber<br />

Crimp Style<br />

Standard Mouth<br />

Wide Mouth<br />

Snap Seal<br />

Snap Ring<br />

Clear or Amber<br />

Clear or Amber<br />

Clear or Amber<br />

Clear or Amber<br />

Additional Vial Options<br />

Limited Volume<br />

High Recovery<br />

Shell Vials<br />

Limited Volume Inserts<br />

with molded<br />

small-volume<br />

shaped inside.<br />

Choice of crimp<br />

or screw thread.<br />

with low dead<br />

volume internal<br />

taper. Choice of<br />

crimp or screw<br />

thread.<br />

Thin-walled<br />

cylinders<br />

For 4 or 6mm i.d. vials.<br />

Top Spring<br />

Straight<br />

sides<br />

Versa-vial w/<br />

pick-up neck<br />

Bottom Spring<br />

Conical<br />

Flat<br />

Bottom<br />

Flanged Top<br />

Step Insert<br />

Self-Centering<br />

Polyethylene<br />

Springs<br />

vials<br />

Properties of Plastics<br />

LDPE<br />

(Low-Density<br />

Polyethylene)<br />

HDPE<br />

(High-Density<br />

Polyethylene)<br />

PP<br />

(Polypropylene)<br />

PMP(TPX)<br />

(Polymethyl-pentene)<br />

PS<br />

(Polystyrene)<br />

PTFE<br />

Max. Temperature 80°C/176°F 120°C/248°F 135°C/275°F 175°C/347°F 90°C/194°F 260°C/500°F<br />

Transparency Translucent Translucent Translucent Clear Clear Opaque<br />

Sterilization Method<br />

Autoclaving No No Yes Yes No Yes<br />

Disinfectants Yes Yes Yes Yes No Yes<br />

Dry Heat No No No Yes No Yes<br />

Radiation Yes Yes No No Yes Yes<br />

Specific Gravity 0.92 0.95 0.90 0.83 1.05 2.14–2.24<br />

Flexibility* Good Rigid Rigid Rigid Rigid Rigid<br />

*Depends on thickness.<br />

Chart is general guideline only. Always test your selection using your test conditions.<br />

Borosilicate Glass Properties<br />

Clear<br />

Amber<br />

Linear Coefficient of Expansion: 33 51<br />

Strain Point (Max. Use Temp.): 515°C 535°C<br />

USP Class Type: Type 1 Type 1<br />

Light Protection: No Yes<br />

Note: Vials in this catalog are not recommended or designed for use with elevated<br />

temperatures, pressures, or vacuum reactions. This restriction includes vials that use<br />

the term “pressure” or “reaction” in the description.<br />

Vial Volumes vs. Dimensions<br />

Volume<br />

Dram<br />

Dimensions<br />

(o.d. x Height)<br />

2mL 0.5 12 x 32mm<br />

4mL 1 15 x 45mm<br />

7mL 2 17 x 60mm<br />

15mL 4 21 x 70mm<br />

22mL 6 23 x 85mm<br />

40mL 10.7 29 x 81mm<br />

348 www.discoverysciences.com


general chromatography<br />

Vial Introduction<br />

Septum Materials Capability<br />

Capability Chart<br />

Natural<br />

(cispolyisoprene)<br />

Butyl<br />

(isobutylene isoprene)<br />

Silicone<br />

(polysiloxane)<br />

PTFE<br />

(polytetra fluorocarbon)<br />

Fluoroelastomer Polymer<br />

(fluorocarbon)<br />

Property:<br />

Specific Gravity (g/cc) 0.93 0.9 1.1–1.6 2.14–2.24 1.4–1.95<br />

Minimum Use Temp. °C -51 -53 -84 -65 -53<br />

Maximum Use Temp. °C 82 149 204 260 260<br />

Hardness (Durometer) 30–90 40–90 30–90 50–65 65–90<br />

Tear Resistance Excellent Good Fair — Poor to Fair<br />

Abrasion Resistance Excellent Good to Excellent Poor — Good<br />

Resealability Good Good Excellent Poor Fair<br />

Chemical Resistance:<br />

Oxidation Good Excellent Excellent Excellent Excellent<br />

Heat Aging Good Excellent Excellent Excellent Excellent<br />

Solvents<br />

Aliphatic Hydrocarbons Poor Poor Fair Excellent Excellent<br />

Aromatic Hydrocarbons Poor Poor Poor Excellent Excellent<br />

Alcohols Good Very Good Excellent Excellent Excellent<br />

Oil, Gasoline Poor Poor Poor Very Good Very Good<br />

Animal, Vegetable Oils Poor to Good Excellent Excellent Very Good Very Good<br />

Acids Fair to good Excellent Very Good Excellent Good to Excellent<br />

Alkalies — — — Excellent Poor to Good<br />

Permeability to Gases Low Very Low High — Low<br />

Water-swell Resistance Fair Excellent Excellent Excellent Excellent<br />

Note: 1. Chemical resistance data are general guides only. Many factors such as temperature, chemical combinations, concentration, pressure, exposure time, etc. can influence<br />

or alter the resistance characteristics of a product. Always test your selection using your test conditions. As a general rule, as temperature increases, resistance to attack decreases.<br />

2. Combination septum (Ex. PTFE/Silicone) has the resistance of the facing material (PTFE) prior to puncture. After puncture, a small portion of the other material is exposed and its<br />

sealing and resistance characteristics must then be considered. 3. Colored closures and septa are free of heavy metals to comply with CONEG standards.<br />

How to Measure for Vial, Cap, and Septum Selection<br />

Bottles and caps are described with a two-part number system<br />

referred to as the Finish*. (Example: 13/425). The first number<br />

represents the neck size of the vial or cap in millimeters.<br />

The vial is measured from the outside edge of the threads on<br />

one side to the outer edge of the threads on the opposite side<br />

(Figure 1). The cap is measured from one side of the inner<br />

wall to the opposite side of the inner wall (Figure 2).<br />

Septum size can be determined by comparing septa or crimp<br />

seals to the measured circles (Figure 4).<br />

Actual Size<br />

18mm<br />

8mm<br />

20mm<br />

11mm<br />

22mm<br />

13mm<br />

24mm<br />

15mm<br />

Figure 4<br />

Figure 1 Figure 2<br />

The second number describes the thread pattern and assures<br />

the bottle and cap will fit together (Figure 3).<br />

400 425 350 430 415<br />

With combination septa (Ex: PTFE/silicone, 5/55), the<br />

numbers represent the thickness of the individual components<br />

of the septum in mils. This same septum could be described<br />

as 0.060" or 60 mil.<br />

Durometer or hardness of septum material is referred to as<br />

“shore” and is an important consideration in working with<br />

some autosamplers (45-60 shore is the typical range for<br />

autosampler septa). Septa with slits or molded starburst<br />

patterns (Figure 5) allow easier needle penetration which can<br />

prevent needles bending or jamming on the autosampler arm.<br />

vials<br />

Figure 3<br />

*Neck finish specifications of both caps and vials are controlled by the GCMI-Glass<br />

Container Manufacturers Institute.<br />

Septum with<br />

Starburst<br />

Figure 5<br />

Septum with Slit<br />

www.discoverysciences.com<br />

349


general chromatography<br />

Actual Size Drawings of Vials with Fill Volumes<br />

12x32mm Standard Mouth Vials and Inserts<br />

1.5mL<br />

C-66002<br />

A-95221<br />

12mm<br />

32mm<br />

1.5mL<br />

C-95191<br />

A-95194<br />

12mm<br />

32mm<br />

100<br />

mL<br />

27mm<br />

4mm<br />

95203<br />

100<br />

µL<br />

30mm<br />

5mm<br />

98107<br />

12x32mm WIDE Mouth Vials & Inserts<br />

200<br />

µL<br />

30mm<br />

5mm<br />

98028<br />

PP-99176<br />

100<br />

µL<br />

31mm<br />

5mm<br />

C-95201<br />

PP-98137<br />

50<br />

µL<br />

25mm<br />

4mm<br />

98018<br />

100<br />

µL<br />

30mm<br />

5mm<br />

C-98031<br />

PP-98069<br />

Abbreviation Key<br />

A = Amber<br />

BT = Bevel Top, Rounded or<br />

Flat Bottom<br />

C = Clear Glass<br />

Gl/Pl = Glass Insert/Plastic Outside<br />

Gl/Gl = Glass Insert/Glass Outside<br />

PE = Polyethylene<br />

PP = Polypropylene<br />

TPX = Polymethylpentene (PMP)<br />

Part Numbers are indicated in Bold.<br />

Unless otherwise indicated, vials are clear glass.<br />

400<br />

µL<br />

30mm<br />

250<br />

µL<br />

29mm<br />

250<br />

µL<br />

31mm<br />

100<br />

µL<br />

30mm<br />

250<br />

µL<br />

29mm<br />

50<br />

µL<br />

25mm<br />

1.5mL<br />

1.5mL<br />

32mm<br />

1.5mL<br />

32mm<br />

1.5mL<br />

32mm<br />

C-95160<br />

A-95163<br />

C-98030<br />

A-98095<br />

12mm<br />

C-98213<br />

A-98245<br />

12mm<br />

C-98133<br />

A-98135<br />

12mm<br />

6mm<br />

981391<br />

PP-99183<br />

6mm<br />

C-98322<br />

PP-98106<br />

6mm<br />

C-98745<br />

PP-98729<br />

5mm<br />

C-98052<br />

PP-92102<br />

6mm<br />

C-98049<br />

PP-98108<br />

6mm<br />

98024<br />

12x32mm Robotic Autosampler Vials<br />

12x32mm Conical Vials<br />

1.5mL<br />

100µL<br />

32mm<br />

1.5mL<br />

1.1mL<br />

32mm<br />

1.1mL<br />

32mm<br />

1.1mL<br />

32mm<br />

C-95386<br />

A-95388<br />

PP-90273<br />

72013<br />

R.A.M.<br />

12mm<br />

R.A.M.<br />

R.A.M.<br />

12mm<br />

12mm<br />

12mm<br />

74125 74145<br />

74135<br />

12x32mm Limited Volume Vials (One Piece, No Assembly)<br />

vials<br />

100µL<br />

C-95183<br />

32mm<br />

1.5mL 300<br />

µL<br />

C-72016<br />

32mm<br />

100µL<br />

PP-12960<br />

TPX-12968<br />

32mm<br />

300<br />

µL<br />

Gl/Gl-<br />

98086<br />

32mm<br />

200µL<br />

Gl/Pl-<br />

98230<br />

32mm<br />

.5mL<br />

PP-98842<br />

TPX-72011<br />

32mm<br />

750µL<br />

PP-98050<br />

TPX-72015<br />

32mm<br />

0.5mL<br />

PP-98310<br />

32mm<br />

0.7mL<br />

PP-98099<br />

32mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

100µL<br />

C-9480<br />

32mm<br />

300µL<br />

PP-12990<br />

300<br />

µL<br />

C-95240<br />

A-95268<br />

32mm<br />

0.5mL<br />

PP-12964<br />

32mm<br />

1.5mL 300<br />

µL<br />

C-72009<br />

32mm<br />

100µL<br />

C-9482<br />

32mm<br />

100µL<br />

PP-12962<br />

TPX12970<br />

32mm<br />

200µL<br />

Gl/Pl-<br />

98220<br />

32mm<br />

0.5mL<br />

PP-12966<br />

32mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

12mm<br />

350 www.discoverysciences.com


general chromatography<br />

15x45mm 4mL WISP Style Vials and Inserts<br />

4mL<br />

4 mm<br />

300<br />

µL<br />

45mm<br />

2mL<br />

45mm<br />

4mL<br />

45mm<br />

300<br />

µL<br />

45mm<br />

2mL<br />

45mm<br />

3 mL<br />

300<br />

mL<br />

38mm<br />

350<br />

µL<br />

42mm<br />

300<br />

µL<br />

38mm<br />

300<br />

µL<br />

38mm<br />

C-98110<br />

A-98120<br />

mm<br />

98251<br />

Gl/Pl<br />

15mm<br />

PP-98091<br />

15mm<br />

C-98040<br />

A-98097<br />

15mm<br />

98154<br />

Gl/Pl<br />

15mm<br />

PP-98054<br />

15mm<br />

PP-98972<br />

6mm<br />

C-98118<br />

PP-98071<br />

8mm<br />

98942<br />

PP99165<br />

6mm<br />

C-98056<br />

PP-92104<br />

6mm<br />

C-98199<br />

PP-98193<br />

8mm Crimp Top<br />

8x40mm 1mL WISP Style<br />

Misc.<br />

98226<br />

500<br />

µL<br />

C-98819<br />

A-98757<br />

8mm<br />

C-98148<br />

A-98894<br />

700<br />

µL<br />

40mm<br />

30mm<br />

500<br />

µL<br />

A-98183<br />

8mm<br />

800<br />

µL<br />

30mm<br />

C-98043<br />

A-98896<br />

40mm<br />

200<br />

µL<br />

94450<br />

6mm<br />

98403<br />

700<br />

µL<br />

32mm<br />

200<br />

µL<br />

94470<br />

32mm<br />

6mm<br />

32mm<br />

98401<br />

500<br />

µL<br />

900µL<br />

C-98226<br />

Sleeve-<br />

98217<br />

10mm<br />

32mm<br />

32mm<br />

1mL<br />

8mm<br />

98494<br />

800<br />

µL<br />

40mm<br />

C-98210<br />

A-98214<br />

PP-98825<br />

40mm<br />

700<br />

µL<br />

PP-98990<br />

98799<br />

1mL<br />

40mm<br />

100<br />

µL<br />

5mm<br />

100<br />

µL<br />

36mm<br />

PP99175<br />

98900<br />

PP99185<br />

98227<br />

36mm<br />

98273<br />

2mL<br />

12mm<br />

C-50303400<br />

A-98921<br />

1mL<br />

35mm<br />

40mm<br />

800µL<br />

10mm<br />

98821<br />

4mL<br />

65mm<br />

32mm<br />

5mL<br />

98187<br />

96mm<br />

8mL<br />

98250<br />

100mm<br />

7mm 7mm 7mm<br />

Headspace Vials<br />

BT-99136<br />

7mm<br />

8mm<br />

8mm<br />

5mm<br />

8mm<br />

13mm<br />

12mm<br />

13mm<br />

75mm<br />

23mm<br />

20mL<br />

23mm<br />

BT-98792<br />

BT-99132 23mm<br />

10mL<br />

10mL<br />

6mL<br />

22mm<br />

38mm<br />

46mm<br />

C-6636<br />

Long Neck<br />

Flat Bottom<br />

C-99097<br />

Spec. Crimp<br />

SPME<br />

C-97127<br />

For PE<br />

C-97188<br />

Long Neck<br />

Round Bottom<br />

C-BT98788<br />

A-BT99077 for PE<br />

Bevel Top<br />

Round Bottom<br />

75.5mm<br />

22.5mm<br />

C-99065<br />

A-99068<br />

46mm<br />

22.5mm<br />

C-99070<br />

A-99078<br />

For CTC PAL<br />

65mm<br />

18mm<br />

98104<br />

12mL<br />

98098<br />

9mL<br />

18mm<br />

50mm<br />

98093<br />

27mL<br />

30mm<br />

56mm<br />

vials<br />

www.discoverysciences.com<br />

351


general chromatography<br />

vials<br />

Vial Selection by<br />

Autosampler<br />

12x32 Screw<br />

Thread, 8/425,<br />

12x32 Crimp Style<br />

Autosampler Chart<br />

Autosampler Manufacturer Model<br />

Agilent 1100, 1200<br />

• •<br />

8042, 1050, 1084, 1080<br />

•<br />

•<br />

7670A, 7671A, 7672, 1042<br />

•<br />

1090 (LC), 1082, 7673A/B,<br />

•<br />

Headspace<br />

7673, 7683<br />

•<br />

• •<br />

Alcott 738<br />

• • • •<br />

718AL, 719D<br />

• • • • •<br />

Alltech (<strong>Grace</strong>) 570, 580 (standard tray) • • • •<br />

Beckman 501, 502, 507<br />

•<br />

• •<br />

•<br />

504<br />

•<br />

508<br />

• • • •<br />

Carlo Erba/Fisons AS-V42, AS 105<br />

•<br />

•<br />

Instruments<br />

AS-V 60<br />

AS 800, 8000<br />

• •<br />

•<br />

•<br />

A200S<br />

•<br />

HS250<br />

Dynatech/Precision 42 Vial Tray, LC 2000<br />

• • • •<br />

Sampling<br />

60 Vial Tray<br />

GC111, 311<br />

• •<br />

•<br />

•<br />

• •<br />

Finnigan A200S • • •<br />

Gilson 232-401, 231-401<br />

• •<br />

•<br />

• •<br />

Asted<br />

• •<br />

•<br />

Aspec<br />

• •<br />

•<br />

Hitachi**<br />

AS-2000, AS-6000<br />

• •<br />

•<br />

S6551<br />

•<br />

L-7200, 7250<br />

•<br />

• • •<br />

Jasco**<br />

851-AS, AS-950<br />

LC 800,900 Series<br />

AS-2055/2057/2059<br />

Leap Technologies CTC A200S<br />

CTC A105S<br />

Headspace<br />

LDC<br />

Marathon, Promis<br />

713<br />

Others<br />

PerkinElmer<br />

Autosystem<br />

Integral 4000<br />

AI-1, ISS100, ISS200<br />

LC600 42 Tray<br />

LC600 (60), AS100<br />

420/B, 4900<br />

AS100B, AS300, 8300<br />

AS2000, LC30, 2000, B2000<br />

Headspace, HS40<br />

Series 200<br />

Pharmacia LKB 2157-010<br />

2157-020<br />

Phillips/Pye UNICAM LC-XP<br />

S4, S8, 4700LC/GC<br />

4247, 4710<br />

Shimadzu**<br />

AOC-8B/9, SIL-6A<br />

AOC-14/1400, AOC-17<br />

SIL-2AS<br />

SIL-6B, -9A, -8A, -10A<br />

Headspace HSS-2B<br />

AOC-20i/20S<br />

AOC-5000<br />

LC-10A<br />

SIL-Hta/SIL-HTc<br />

Spark Holland SPH 125<br />

Marathon<br />

Promis<br />

Triathlon, Midas<br />

Spectra-Physics/TSP 8875, 8880<br />

AS100/1000;300/3000<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

12x32 Screw Thread,<br />

10/425<br />

•<br />

12x32 Screw Thread,<br />

Robotic<br />

15x45, Screw Thread,<br />

13/425<br />

15x45, Crimp Style<br />

8x40 Crimp Style<br />

8x30 Crimp Style<br />

7x32 Crimp Style<br />

7x40 Crimp Style<br />

• •<br />

• • • • •<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

• •<br />

• •<br />

• • •<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

• •<br />

• • • • •<br />

•<br />

•<br />

• •<br />

•<br />

• •<br />

•<br />

• •<br />

•<br />

•<br />

•<br />

•<br />

Varian Prostar 400, 410, 430 • • •<br />

8000, 9000 Series • • • •<br />

Waters Alliance ® 2690<br />

• • • •<br />

48-Position<br />

96-Position<br />

717<br />

•<br />

Alliance ®<br />

•<br />

• •<br />

Acquity UPLC ®<br />

•<br />

Breeze<br />

• •<br />

• •<br />

2710 Sample Manager<br />

•<br />

• •<br />

**Special Cap is Required.<br />

•<br />

12x32 Snap Seal<br />

Wide Mouth<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

• • •<br />

•<br />

•<br />

•<br />

6x32 Crimp Style<br />

Headspace<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Specialty<br />

• •<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

352 www.discoverysciences.com


general chromatography<br />

Vials by Autosampler Part No. Cross Reference<br />

Autosampler Part No. Cross Reference Chart<br />

Agilent PerkinElmer Varian Waters <strong>Grace</strong> Description<br />

12x32mm Standard Mouth Screw Thread Vials<br />

5183-4428 N930-2945 392611639 — 95191 8/425 Clear Screw Thread Vial<br />

5183-4429 — 392611640 — 95194 8/425 Amber Screw Thread Vial<br />

— — — WAT094174 98061 8/425 Black Polypropylene (PP) Open-Hole Cap with PPTFE/Silicone Septum<br />

5183-4442 N930-3441 392611641 — 980611 8/425 Flush-fit Black PP Open-Hole Cap with PTFE/Silicone Septum<br />

12x32mm Wide Mouth Screw Thread Vials<br />

— — 392611646 WAT063300 98133 10/425 Clear Screw Thread Vial<br />

5182-3454 — — 186000984 72009 High Recovery Vial (HRV), Wide Mouth Crimp<br />

— — 392611650 WAT094174 98144 10/425 Black PP Open-Hole Cap with PTFE/Silicone Septum<br />

— — — WAT058876 97013 10/425 Black PP Open-Hole Cap with PTFE/Silicone Septum with Slit<br />

12x32mm Vials for Use with Robotic Arm, Wide Mouth, Screw Thread Vials<br />

5182-0714 — 392611653 186000273 95386 R.A.M. Clear Vial for Robotics<br />

5182-0715 — — — 88540 R.A.M. Clear Vial with Marking Spot for Robotics<br />

5182-0716 — 392611654 186000848 88542 R.A.M. Amber Vial with Marking Spot for Robotics<br />

5183-2030 — — — 72013 High Recovery Vial (HRV) for Robotics<br />

5182-0717 — 392611661 — 95308 9mm Blue Cap with PTFE/Butyl Septum<br />

5182-0720 — 392611659 186000274 95360 9mm Blue Cap with PTFE/Silicone Septum<br />

5183-2076 — 392611660 186000305 95385 9mm Blue Cap with PTFE/Silicone Septum with Slit<br />

12x32mm Standard Mouth Crimp Style Vials<br />

— N930-1385 392611626 — 66002 12x32mm Clear Standard Mouth Crimp Vial<br />

— N930-2680 392611628 — 95221 12x32mm Amber Standard Mouth Crimp Vial<br />

5182-0544 — — WAT094219 98030 12x32mm Clear Snap Ring Vial<br />

5182-0546 — — — 98033 12x32mm Clear Snap Ring Vial with Marking Spot<br />

5182-0545 — — WAT094220 98083 12x32mm Amber Snap Ring Vial with Marking Spot<br />

5182-0550 — — — 98038 11mm Snap TOP Cap with PTFE/Butyl Septum<br />

5182-0541 — — 186000303 98034 11mm Snap TOP Cap with PTFE/Silicone Septum<br />

5183-4511 — — 186000304 98168 11mm Snap TOP Cap with PTFE/Silicone Septum with Slit<br />

— — 392611875 — 95232 11mm Poly Crimp Seal with PTFE/Butyl Septum<br />

— — 392611873 — 95234 11mm Poly Crimp Seal with PTFE/Silicone Septum<br />

— — 392611874 — 95325 11mm Poly Crimp Seal with PTFE/Silicone Septum with Slit<br />

12x32mm Wide Mouth Crimp Style Vials<br />

5181-3375 — 392611634 WAT094222 98213 12x32mm Clear Wide Mouth Crimp Vial<br />

5182-0543 — — — 98001 12x32mm Clear Wide Mouth Crimp Vial with Marking Spot<br />

5181-3376 — 392611635 WAT094223 98003 12x32mm Amber Wide Mouth Crimp Vial with Marking Spot<br />

11mm Aluminum Seals for 12x32mm Standard and Wide Mouth Crimp Style Vials<br />

5181-1210 N930-6015 392611632 — 73070 11mm Aluminum Seal with PTFE/Butyl Septum<br />

5182-0552 — 392611631 — 98740 11mm Aluminum Seal with PTFE/Silicone Septum<br />

Limited Volume Inserts for 12x32mm Autosampler Vials, i.d. as noted<br />

5183-2089 N930-2681 392611593 — 95201 100µL LV Glass Insert for Standard Mouth Vial<br />

5183-2088 — 392611591 — 98031 100µL LV Glass Insert with Polyethylene (PE) Bottom Spring for Std Mouth Vial<br />

5183-2090 — — — 98028 250µL LV Glass Flat bottom Insert for Standard Mouth Vial<br />

5183-2085 — 392611596 — 98322 250µL LV Glass Insert for Wide Mouth Vial<br />

5181-1270 — 392611594 WAT094170 98049 250µL LV Glass Insert with PE Bottom Spring for Wide Mouth Vial<br />

5181-3377 — — — 981391 400µL LV Glass Flat Bottom Insert for Wide Mouth Vial<br />

5182-0549 — — — 98108 250µL LV PP Insert with PE Bottom Spring for Wide Mouth Vial<br />

5183-2087 — — — 99183 350µL LV PP Flat Bottom Insert for Wide Mouth Vial<br />

15x45mm (4mL) Vials<br />

5183-4448 — — 186000840 98110 15x45mm Clear Glass Vial<br />

5183-4450 — — 186001135 98120 15x45mm Amber Glass Vial<br />

5183-4464 — — 186000841 98610 13/425 Black PP Open-Hole Cap with PTFE/Silicone Septum<br />

— — — 186000842 97017 13/425 Black PP Open-Hole Cap with PTFE/Silicone Septum with Slit<br />

— — — WAT015199 98118 300µL Glass Limited Volume Insert, 6x38mm<br />

8x40mm (1mL) WISP Style Vials<br />

— — — WAT078515 88613 8mm PE Starburst Snap Plugs, Clear<br />

Note: This list contains some of the more popular products used in these instruments. Every effort has been made to provide the <strong>Grace</strong> equivalent product or one most similar to the<br />

manufacturers’ product description. There are many more <strong>Grace</strong> ® vial, cap, liner, and kit combinations available on the individual product page listings.<br />

vials<br />

related products<br />

Accessories for your system. <strong>Grace</strong><br />

has an assortment of Accessories<br />

Quick Reference guides available for<br />

many popular instruments.<br />

• Waters ® Alliance ®<br />

System Accessories<br />

– Request M202<br />

• Agilent 1100 and 1200<br />

System Accessories<br />

– Request M203<br />

• Waters ® Acquity ®<br />

System Accessories<br />

– Request M204<br />

www.discoverysciences.com<br />

353


general chromatography<br />

8x40mm (1mL) Shell Vials<br />

• Shell vials with thicker walls for safer sample handling<br />

• 8x40mm vials for Waters ® WISP 96 style autosamplers<br />

8x40mm Shell Vials for WISP 96 Style<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Description<br />

Shell Vials, 1mL, 8x40mm, Use 8mm Snap Plugs<br />

Clear Shell Vial 88610 98212<br />

Amber Shell Vial 88614 98216<br />

Polypropylene Shell Vial 88625 98827<br />

Silanized, Clear Shell Vial 886101 —<br />

Limited Volume Shell Vial, 8mm, Use Polyethylene Conical Snap Plugs<br />

8x40mm Polypropylene Vial, 700µL 98990 98992<br />

8x40 Shell Vial Kits are Ideal for Waters ® or<br />

Shimadzu ® Autosamplers<br />

Convenience kits simplify ordering with one part number to<br />

remember. Kits provide both vials and caps for a perfect fit<br />

every time.<br />

4718<br />

best<br />

value<br />

8x40mm Vial Kits<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Description<br />

8x40mm Shell Vial Kits for WISP Style Autosamplers<br />

Clear Vials, Clear Snap Plugs with Starburst † 88617 73021<br />

Amber Vials, Clear Snap Plugs with Starburst † 88597 73003<br />

Polypropylene Vials, Clear Snap Plugs with<br />

88626 98224<br />

Starburst †<br />

Clear Silanized Vials, Clear Snap Plugs 982108 —<br />

8x40mm Shell Vial Kits for Shimadzu ® Autosamplers<br />

Clear Vials, Clear Easy Pierce Snap Plugs with<br />

Starburst †<br />

Amber Vials, Clear Easy Pierce Snap Plugs with<br />

Starburst*<br />

*Use to prevent bent needles.<br />

†<br />

Thinner starburst for use with Shimadzu ® autosamplers.<br />

70118 70132<br />

70134 70136<br />

vials<br />

Limited Volume Inserts for 8x40 Shell Vials<br />

• Select the appropriate limited volume insert for your<br />

microsampling needs<br />

• Polyethylene springs act as shock adsorbers and help<br />

maintain proper insert alignment<br />

6308<br />

4741<br />

Limited Volume Inserts for 8x40mm Shell Vials<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Description<br />

Glass<br />

150µL, 5x29mm, Requires Spring 95201 95202<br />

150µL, with Bottom Spring, 5x29mm 73054 73074<br />

200µL, 5x36mm 98900 98902<br />

200µL, with Bottom Spring, 5x36mm 98227 98229<br />

250µL, with Bottom Spring, 6x29mm 98658 98660<br />

200µL, 5x31mm 73024 73025<br />

Metal Springs for Inserts 73026 73027<br />

200µL, Silanized, No Spring 989008 —<br />

Polypropylene<br />

250µL, 6x31mm, No Spring 98106 98406<br />

250µL, with Bottom Spring, 6x31mm 98108 98408<br />

200µL, with Bottom Spring, 5x36mm 99185 99187<br />

Polyethylene Snap Plugs with Starburst † 8mm<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Description<br />

Easy Pierce Snap Plug †<br />

Clear Plug 70117 70129<br />

Snap Plug with Starburst*<br />

Clear Plug 88613 98865<br />

Red Plug 88618 98228<br />

Blue Plug 88615 98232<br />

Green Plug 88622 98234<br />

Yellow Plug 88624 98879<br />

Silicone Lined Snap Plug, Clear, Resealable 98662 98664<br />

Conical Snap Plug for Limited Volume Polyethylene Vial<br />

Clear Plug 98994 98996<br />

Red Plug 99003 99013<br />

Blue Plug 99005 99015<br />

Green Plug 99007 99017<br />

Yellow Plug 99009 99019<br />

*Use to prevent bent needles.<br />

†<br />

Thinner starburst for use with Shimadzu ® autosamplers.<br />

354 www.discoverysciences.com


general chromatography<br />

12x32mm R.A.M. Robotic Screw Thread Vials<br />

• Works on virtually every autosampler<br />

• Use to replace crimp vials for use with robotic arms<br />

on autosamplers<br />

• Crimp style height with screw thread configuration<br />

• Incorporates unique StepVial design to precisely<br />

align insert and vial<br />

• Economical kits simplify ordering<br />

• Choose pre-slit septa for Waters ® Acquity ® Systems<br />

Silanized<br />

With White<br />

Marking Spot<br />

With White Graduated<br />

Marking Spots<br />

100/pk 1000/pk 100/pk 100/pk 1000/pk 100/pk 1000/pk<br />

Vials<br />

Clear 95386 95387 953861 88540 88544 95521 95522<br />

Amber 95388 95389 953881 88542 88546 95531 95532<br />

Limited Volume Vials<br />

1.5mL High Recovery Vials 72013 — — — — — —<br />

100µL Polypropylene Vials 90273 90271 — — — — —<br />

100µL PMP (TPX) Vials 95096 95098 — — — — —<br />

Kits: Vials Open-Hole Caps with Septa<br />

Clear Vials 9mm PTFE/Butyl Septa 89135 89136 — 89120 89126 — —<br />

Amber Vials 9mm PTFE/Butyl Septa 98004 98006 — 89125 89127 — —<br />

Clear Vials 9mm PTFE/Silicone Septa 89145 89146 953868 89100 89104 — —<br />

Clear Vials 9mm PTFE/Silicone/PTFE Septa 89149 89139 — 89128 89129 — —<br />

Amber Vials 9mm PTFE/Silicone/PTFE Septa 89151 89152 — 89130 89131 — —<br />

9mm R.A.M. Open-Hole Caps with Septa<br />

Blue Cap Bonded Interseal PTFE/Silicone Septa with Slit 70416 70418 — 70416 70418 70416 70418<br />

Blue Cap Bonded Interseal PTFE/Silicone Septa 70415 70417 — 70415 70417 70415 70417<br />

Black Cap PTFE/Silicone Septa with Slit 95380 95382 — 95380 95382 95380 95382<br />

Blue Cap PTFE/Silicone Septa with Slit 95385 95390 — 95385 95390 95385 95390<br />

Black Cap PTFE/Butyl Septa 95320 95319 — 95320 95319 95320 95319<br />

Blue Cap PTFE/Butyl Septa 95308 95311 — 95308 95311 95308 95311<br />

Clear Cap PTFE/Butyl Septa 95352 95348 — 95352 95348 95352 95348<br />

Green Cap PTFE/Butyl Septa 95346 95344 — 95346 95344 95346 95344<br />

Red Cap PTFE/Butyl Septa 95356 95354 — 95356 95354 95356 95354<br />

Yellow Cap PTFE/Butyl Septa 95358 95357 — 95358 95357 95358 95357<br />

Black Cap PTFE/Silicone Septa with Slit 95324 95342 — 95324 95342 95324 95342<br />

Blue Cap PTFE/Silicone Septa with Slit 95360 95359 — 95360 95359 95360 95359<br />

Clear Cap PTFE/Silicone Septa with Slit 95365 95364 — 95365 95364 95365 95364<br />

Green Cap PTFE/Silicone Septa with Slit 95362 95361 — 95362 95361 95362 95361<br />

Red Cap PTFE/Silicone Septa with Slit 95367 95366 — 95367 95366 95367 95366<br />

Yellow Cap PTFE/Silicone Septa with Slit 95377 95378 — 95377 95378 95377 95378<br />

Black Cap PTFE/Silicone/PTFE Septa 95328 95338 — 95328 95338 95328 95338<br />

Blue Cap PTFE/Silicone/PTFE Septa 95379 95381 — 95379 95381 95379 95381<br />

Clear Cap PTFE/Silicone/PTFE Septa 95371 95370 — 95371 95370 95371 95370<br />

Green Cap PTFE/Silicone/PTFE Septa 95369 95368 — 95369 95368 95369 95368<br />

Red Cap PTFE/Silicone/PTFE Septa 95374 95372 — 95374 95372 95374 95372<br />

Yellow Cap PTFE/Silicone/PTFE Septa 95376 95375 — 95376 95375 95376 95375<br />

9mm Unlined, Open-Hole R.A.M. Caps<br />

Black Cap 90257 90268 — 90257 90268 90257 90268<br />

Red Cap 90259 90270 — 90259 90270 90259 90270<br />

Blue Cap 90261 90272 — 90261 90272 90261 90272<br />

Green Cap 90263 90274 — 90263 90274 90263 90274<br />

Yellow Cap 90265 90276 — 90265 90276 90265 90276<br />

Clear Cap 90267 90278 — 90267 90278 90267 90278<br />

Septa for 9mm R.A.M. Caps<br />

PTFE/Red Rubber—40mil 88701 88691 — 88701 88691 88701 88691<br />

PTFE/Silicone—40mil 88705 88695 — 88705 88695 88705 88695<br />

PTFE/Silicone/PTFE—40mil 88710 88699 — 88710 88699 88710 88699<br />

4715<br />

12x32mm R.A.M. Robotic Specifications<br />

32mm<br />

12mm<br />

Neck Style: Screw Thread<br />

Required Closure:<br />

9mm R.A.M. Screw Thread Caps<br />

Wide Mouth Opening:<br />

9mm o.d., 6mm i.d.<br />

vials<br />

more info<br />

12x32 R.A.M. Vials are compatible with Waters ®<br />

Alliance ® and Acquity ® Systems, Agilent 1100 &<br />

1200, and Varian ® 8000 & 9000. Refer to page 352<br />

for more autosampler compatibility.<br />

related products<br />

Do you have small samples?<br />

Choose limited volume vials or see our selection<br />

of limited volume inserts on page 361.<br />

4748<br />

www.discoverysciences.com<br />

355


general chromatography<br />

vials<br />

12x32 Screw Thread Standard Mouth Vials<br />

• Work with a variety of autosamplers that require<br />

narrow neck vials<br />

• Economical kits simplify ordering<br />

more info<br />

Compatible with Waters ® Alliance ® , Hitachi, Jasco,<br />

and Varian ® autosamplers. Refer to page 352 for<br />

more autosampler compatibility.<br />

Silanized<br />

With White<br />

Marking Spot<br />

With White Graduated<br />

Marking Spots<br />

100/pk 1000/pk 100/pk 100/pk 1000/pk 100/pk 1000/pk<br />

Vials<br />

Clear 95191 95192 951911 98068 98161 95481 95482<br />

Amber 95194 95195 951941 98078 98171 95491 95492<br />

Limited Volume Vials<br />

1.1mL Glass Tapered Bottom, requires sleeve 74135 98574 — — — — —<br />

Support Sleeve for 74135 (50/pk) 98558 — — — — — —<br />

100µL Heavy-Walled Glass with PTFE/Silicone-Lined Cap (12/pk, 10x12/pk) 9482 94823 — — — — —<br />

600µL Polypropylene Vials (500/pk) 89073 — — — — — —<br />

100µL Polypropylene Vials 12962 12963 — — — — —<br />

100µL PMP (TPX) Microvials 12970 12971 — — — — —<br />

200µL Glass Insert in Clear Plastic Vial 98220 98222 — — — — —<br />

200µL Glass Insert in Amber Plastic Vial 98225 98899 — — — — —<br />

Preassembled Kits<br />

Vials Caps with Septa<br />

Clear Vials 8/425 Black PTFE Septa—10mil 98533 98535 — — — — —<br />

Clear Vials 8/425 Black PTFE/Butyl Septa—40mil 98380 98382 — — — —<br />

Clear Vials 8/425 Black PTFE/Silicone Septa—45mil 95175 95176 — — — — —<br />

Clear Vials 8/425 Black PTFE/Silicone Septa — — 72666 — — — —<br />

Amber Vials 8/425 Black PTFE/Silicone Septa—45mil 95179 95181 — — — — —<br />

Amber Vials 8/425 Black PTFE/Silicone Septa 72670 — — — — — —<br />

Preassembled Kits Spectra Physics/Varian ®<br />

Vials Caps with Septa<br />

Clear Vials Flush-Fit 8/425 Black PTFE/Silicone Septa 895175 895176 — — — — —<br />

Clear Vials Flush-Fit 8/425 Black PTFE/Butyl Septa 898380 898382 — — — — —<br />

Clear Vials Flush-Fit 8/425 Black PTFE/Silicone/PTFE Septa 898537 898539 — — — — —<br />

Amber Vials Flush-Fit 8/425 Black PTFE/Butyl Septa 898385 898387 — — — — —<br />

Preassembled 8/425 Polypropylene<br />

Open-Hole Caps<br />

with Septa<br />

Black Cap Bonded Interseal PTFE/Silicone Septa 70412 70414 — 70412 70414 70412 70414<br />

Black Flush-Fit Cap PTFE/Silicone Septa 980611 980611 — 980611 980611 980611 980611<br />

Black Cap PTFE/Silicone Septa with Slit 97018 97018 — 97018 97018 97018 97018<br />

Black Cap PTFE/Silicone Septa 98061 98061 — 98061 98061 98061 98061<br />

Black Cap PTFE/Silicone/PTFE Septa 98701 98701 — 98701 98701 98701 98701<br />

Black Cap PTFE/Silicone TOP Hat Septa 98065 98065 — 98065 98065 98065 98065<br />

Yellow Cap PTFE/Silicone TOP Hat Septa 98055 98055 — 98055 98055 98055 98055<br />

Clear Cap TOP Seal Closure, Molded Poly Septa—10mil 98060 98160 — 98060 98160 98060 98160<br />

Solid 8/425 Top Caps<br />

with Septa<br />

Green Phenolic Cap PTFE Septa 73067 98067 — 73067 98067 73067 98067<br />

Black Polypropylene Cap PTFE Septa 98063 98163 — 98063 98163 98063 98163<br />

Black Polypropylene Cap — 98105 98109 — 98105 98109 98105 98109<br />

Open-Hole Unlined 8/425 Caps<br />

Black Flush-Fit Side Cap for Spectra-Physics and Varian ® Autosamplers 730441 730442 — 730441 730442 730441 730442<br />

Black Cap 73044 73059 — 73044 73059 73044 73059<br />

Red Cap 98072 98172 — 98072 98172 98072 98172<br />

Blue Cap 98074 98174 — 98074 98174 98074 98174<br />

Green Cap 98076 98176 — 98076 98176 98076 98176<br />

White Cap 98084 98184 — 98084 98184 98084 98184<br />

White Cap for Shimadzu ® , Hitachi, and Jasco Autosamplers 98087 98089 — 98087 98089 98087 98089<br />

Yellow Cap for Shimadzu ® , Hitachi, and Jasco Autosamplers 73063 73065 — 73063 73065 73063 73065<br />

Septa for 8/425 Caps<br />

PTFE/Silicone with Slit—5/40mil 98088 98188 — 98088 98188 98088 98188<br />

White PTFE—10mil 98094 98194 — 98094 98194 98094 98194<br />

Red PTFE/White Silicone—5/55mil 73048 73060 — 73048 73060 73048 73060<br />

Red PTFE/White Silicone—5/60mil 98096 98196 — 98096 98196 98096 98196<br />

PTFE/Silicone—10/90mil 98499 98497 — 98499 98497 98499 98497<br />

Blue PTFE/White Silicone—5/60mil 98747 98749 — 98747 98749 98747 98749<br />

PTFE/Silicone/PTFE—2/36/2mil 98081 98181 — 98081 98181 98081 98181<br />

PTFE/Butyl—5/40mil 98190 98192 — 98190 98192 98190 98192<br />

Black Fluoroelastomer Polymer—30mil 98026 98047 — 98026 98047 98026 98047<br />

4684<br />

12x32mm Screw Thread Std. Mouth Specifications<br />

32mm<br />

12mm<br />

Neck Style: Screw Thread<br />

Required Closure:<br />

8/425mm Screw Thread Caps<br />

Standard Mouth Opening:<br />

8mm o.d., 4mm i.d.<br />

356 www.discoverysciences.com


general chromatography<br />

12x32mm Screw Thread Wide Mouth Vials<br />

• 40% larger opening aids in sample<br />

transfers<br />

• Larger target area prevents bent needles<br />

• StepVial design precisely aligns insert<br />

and vial<br />

• Economical kits simplify ordering<br />

4711<br />

12x32mm Screw Thread Wide Mouth Specifications<br />

32mm<br />

12mm<br />

Neck Style: Wide Mouth Screw Thread<br />

Required Closure:<br />

10/425mm Screw Thread Caps<br />

Wide Mouth Opening:<br />

10mm o.d., 6mm i.d.<br />

Silanized<br />

With White<br />

Marking Spot<br />

With White Graduated<br />

Marking Spots<br />

100/pk 1000/pk 100/pk 100/pk 1000/pk 100/pk 1000/pk<br />

Vials<br />

Clear 98133 98433 981331 98291 98295 95501 95502<br />

Amber 98135 98435 981351 98622 98624 95511 95512<br />

Limited Volume Vials<br />

500µL Polypropylene Vial 98310 98314 — — — — —<br />

750µL Polypropylene Vial 98099 98211 — — — — —<br />

Preassembled Kits:<br />

Vials Caps with Septa<br />

Clear Vials Black 10/425 PTFE Septa 98891 98906 — — — — —<br />

Clear Vials Black 10/425 PTFE/Silicone Septa 98893 98908 981338 — — — —<br />

Clear Vials Black 10/425 PTFE/Silicone/PTFE Septa 98895 98910 — — — — —<br />

Clear Vials Black 10/425 PTFE/Butyl Septa 98290 98292 — — — — —<br />

Amber Vials Black 10/425 PTFE Septa 98274 98277 — — — — —<br />

Amber Vials Black 10/425 PTFE/Silicone Septa 98281 98284 981358 — — — —<br />

Amber Vials Black 10/425 PTFE/Butyl Septa 98294 98296 — — — — —<br />

Unassembled Kits:<br />

Vials Caps with Septa<br />

Clear Vials Black 10/425 PTFE/Silicone Septa 97239 97229 — — — — —<br />

Amber Vials Black 10/425 PTFE/Silicone Septa 97249 97259 — — — — —<br />

Preassembled 10/425<br />

Open-Hole Caps<br />

with Septa<br />

Black Cap Bonded Interseal PTFE/Silicone Septa w/Slit 70422 70426 — 70422 70426 70422 70426<br />

Black Cap Bonded Interseal PTFE/Silicone Septa 70411 70413 70411 70413 70411 70413<br />

Black Cap PTFE/Silicone Septa with Slit 97013 97023 — 97013 97023 97013 97023<br />

Black Cap PTFE/Silicone Septa 98144 98152 — 98144 98152 98144 98152<br />

Black Cap PTFE/Silicone/PTFE Septa 98705 98707 — 98705 98707 98705 98707<br />

Black Cap PTFE/Red Rubber Septa 97274 97216 — 97274 97216 97274 97216<br />

Clear Cap TOP Seal Closure, Molded Poly Septa 98405 98407 — 98405 98407 98405 98407<br />

Solid Polypropylene 10/425 Top Caps with Septa<br />

Black Cap PTFE Septa 98124 98424 — 98124 98424 98124 98424<br />

Black Cap 98162 98167 — 98162 98167 98162 98167<br />

Unlined 10/425 Caps<br />

Black Cap 98143 98443 — 98143 98443 98143 98443<br />

Red Cap 98136 98436 — 98136 98436 98136 98436<br />

Blue Cap 98138 98438 — 98138 98438 98138 98438<br />

Green Cap 98140 98440 — 98140 98440 98140 98440<br />

Yellow Cap 98122 98134 — 98122 98134 98122 98134<br />

White Cap 98126 98426 — 98126 98426 98126 98426<br />

Septa for 10/425 Caps<br />

PTFE/Silicone with Slit—5/55mil 98021 98421 — 98021 98421 98021 98421<br />

White PTFE—10mil 98023 98423 — 98023 98423 98023 98423<br />

Red PTFE/White Silicone—5/55mil 98141 98441 — 98141 98441 98141 98441<br />

Red PTFE/White Silicone—5/65mil 98025 98425 — 98025 98425 98025 98425<br />

PTFE/Silicone/PTFE—2/36/2mil 98027 98427 — 98027 98427 98027 98427<br />

PTFE/Butyl Rubber—5/40mil 98029 98429 — 98029 98429 98029 98429<br />

vials<br />

more info<br />

12x32 Screw Thread Wide Mouth Vials are<br />

compatible with Waters ® Alliance ® , Agilent 1100 &<br />

1200, Varian ® 8000 & 9000. Refer to page 352 for<br />

more autosampler compatibility.<br />

related products<br />

Do you have small samples?<br />

Choose limited volume vials or see our selection<br />

of limited volume inserts on page 361.<br />

4748<br />

www.discoverysciences.com<br />

357


general chromatography<br />

12x32mm Crimp Style Standard Mouth Vials<br />

• Work with most autosamplers<br />

• Economical kits simplify ordering<br />

• For small samples use limited volume<br />

vials or inserts — see page 361 for<br />

inserts<br />

12x32mm Crimp Style Std. Mouth Specifications<br />

Neck Style: Crimp Top<br />

32mm<br />

Recommended Closure:<br />

11mm Aluminum Caps<br />

Optional Closures:<br />

11mm Poly Crimp Seals, p359<br />

4712<br />

12mm<br />

Standard Mouth Opening:<br />

11mm o.d., 4mm i.d.<br />

With White<br />

Marking Spot<br />

With White Graduated<br />

Marking Spots<br />

100/pk 1000/pk 100/pk 1000/pk 100/pk 1000/pk<br />

Vials<br />

Clear 66002 66003 98073 98191 95461 95462<br />

Amber 95221 95222 98077 98197 95471 95472<br />

Limited Volume Vials<br />

100µL Glass Heavy Walled (12/pk, 10x12/pk) 9480* 94802* — — — —<br />

600µL Polypropylene Vial (500/pk) — 88363* — — — —<br />

300µL Polypropylene Microvial 12990 12991 — — — —<br />

300µL Polypropylene Microvial (12x31mm) 12982 12983 — — — —<br />

Kits: Vials Seals with Septa<br />

Clear Vials 11mm Aluminum Seals PTFE Septa—10mil 98389 98391 — — — —<br />

Clear Vials 11mm Aluminum Seals PTFE/Silicone Septa 98318 98329 — — — —<br />

Clear Vials 11mm Aluminum Seals PTFE/Butyl Septa 95161 95162 — — — —<br />

Amber Vials 11mm Aluminum Seals PTFE/Silicone Septa 98368 98371 — — — —<br />

Amber Vials 11mm Aluminum Seals PTFE/Butyl Septa 95151 98331 — — — —<br />

11mm Aluminum Caps<br />

with Septa<br />

Silver Cap 1/8" Center Hole with PTFE/Butyl Septa—40mil 98298 98304 98298 98304 98298 98304<br />

Silver Cap PTFE/Butyl Septa—40mil 73070 73071 73070 73071 73070 73071<br />

Red Cap PTFE/Butyl Septa—40mil 98051 98151 98051 98151 98051 98151<br />

Blue Cap PTFE/Butyl Septa—40mil 98053 98153 98053 98153 98053 98153<br />

Green Cap PTFE/Butyl Septa—40mil 98057 98157 98057 98157 98057 98157<br />

Gold Cap PTFE/Butyl Septa—40mil 98059 98159 98059 98159 98059 98159<br />

Silver Cap PTFE/Silicone Septa—3/37mil 98740 94867 98470 94867 98740 94867<br />

Silver Cap PTFE/Silicone/PTFE Septa—2/36/2mil 94855 94865 94855 94865 94855 94865<br />

Silver Cap Black Fluoroelastomer Polymer Septa—40mil 94852 94862 94852 94862 94852 94862<br />

Silver Cap PTFE/Gray Chlorobutyl Septa—2/38mil 98742 94870 98742 94870 98742 94870<br />

Silver Cap Polypropylene Septa—10mil 98011 98111 98011 98111 98011 98111<br />

Silver Cap PTFE Septa—10mil 98013 98113 98013 98113 98013 98113<br />

Unlined 11mm Aluminum Seals<br />

Silver Seal, Open-Hole 98746 66405 98746 66405 98746 66405<br />

Septa for 11mm Aluminum Seals<br />

White PTFE—10mil 98007 98017 98007 98017 98007 98017<br />

PTFE/Silicone—5/55mil 98009 98019 98009 98019 98009 98019<br />

PTFE/Silicone/PTFE—2/36/2mil 98010 98020 98010 98020 98010 98020<br />

PTFE/Butyl Rubber—5/40mil 98398 98400 98398 98400 98398 98400<br />

*See correct quantity specified in description.<br />

vials<br />

more info<br />

12x32mm Crimp Style Vials (on pages 358, 359)<br />

are compatible with Agilent and Varian ®<br />

autosamplers. Refer to page 352 for detailed<br />

autosampler compatibility.<br />

4949<br />

related products<br />

Looking for a crimper or decrimper?<br />

Refer to page 383.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

3309<br />

358 www.discoverysciences.com


general chromatography<br />

12x32mm Crimp Style Wide Mouth Vials<br />

Standard Crimp Top<br />

• 40% larger opening aids<br />

in sample transfers and<br />

prevents bent needles<br />

• StepVial design precisely<br />

aligns insert and vial<br />

• Economical kits simplify ordering<br />

4713<br />

Snap Seal<br />

• Unique design<br />

allows secure seal<br />

• Economical kits<br />

simplify ordering<br />

With White<br />

Marking Spot<br />

With White Graduated<br />

Marking Spots<br />

100/pk 1000/pk 100/pk 1000/pk 100/pk 1000/pk<br />

Snap Seal Vials<br />

Clear 95160 95190 95165 95155 95401 95402<br />

Amber 95163 95153 95167 95157 95411 95412<br />

Crimp Top Vials<br />

Clear 98213 98239 98001 98201 95441 95442<br />

Amber 98245 98249 98003 98203 95451 95452<br />

Snap Seal Limited Volume Vials<br />

100µL Clear Glass Micro Vial, Heavy Wall 95183 — — — — —<br />

1.5mL Clear Glass High Recovery (HRV) Vial 72016 — — — — —<br />

Crimp Top Limited Volume Vials<br />

1.5mL Glass High Recovery (HRV) Vial 72009 — — — — —<br />

2mL Glass Round Bottom Vial 74125 98560 — — — —<br />

1.1mL Glass Tapered Bottom Vial, Requires Sleeve 74145 98562 — — — —<br />

Support Sleeve for 74145 (50/pk) 98558 — — — — —<br />

300µL Clear Glass LVI Vial — — 95240 — — —<br />

300µL Amber Glass LVI Vial — — 95268 — — —<br />

Snap Seal Kits:<br />

Vials Seals with Septa<br />

Clear Vials 11mm Poly Crimp Seals PTFE/Butyl Septa 88487 88491 — — — —<br />

Clear Vials 11mm Poly Crimp Seals PTFE/Silicone Septa 88496 88475 — — — —<br />

Clear Vials 11mm Poly Crimp Seals PTFE/Silicone/PTFE Septa 88494 88473 — — — —<br />

Amber Vials 11mm Poly Crimp Seals PTFE/Butyl Septa 88493 88479 — — — —<br />

Amber Vials 11mm Poly Crimp Seals PTFE/Silicone Septa 88498 88484 — — — —<br />

Crimp Top Kits:<br />

Vials Seals with Septa<br />

Clear Vials 11mm Aluminum Seals PTFE Septa—10mil 98457 98459 — — — —<br />

Clear Vials 11mm Aluminum Seals PTFE/Silicone Septa 98419 98428 — — — —<br />

Clear Vials 11mm Aluminum Seals PTFE/Silicone/PTFE Septa 98447 98451 — — — —<br />

Clear Vials 11mm Aluminum Seals PTFE/Butyl Septa 98397 98404 — — — —<br />

Amber Vials 11mm Aluminum Seals PTFE/Silicone Septa 98434 98437 — — — —<br />

Amber Vials 11mm Aluminum Seals PTFE/Butyl Septa 98413 98417 — — — —<br />

Clear Vials 11mm Poly Crimp Seals PTFE/Silicone Septa 88369 88366 — — — —<br />

Clear Vials 11mm Poly Crimp Seals PTFE/Butyl Septa 88368 88380 — — — —<br />

Amber Vials 11mm Poly Crimp Seals PTFE/Silicone Septa 88375 88378 — — — —<br />

Amber Vials 11mm Poly Crimp Seals PTFE/Butyl Septa 88374 88396 — — — —<br />

11mm Poly Crimp Seals<br />

with Septa<br />

Clear Seal PTFE/Silicone Septa with Slit 95325 95340 95325 95340 95325 95340<br />

Clear Seal PTFE/Silicone Septa with Starburst 95335 95350 95335 95350 95335 95350<br />

Clear Seal PTFE Septa—10mil 95230 95330 95230 95330 95230 95330<br />

Red Seal PTFE Septa—10mil 95207 95341 95207 95341 95207 95341<br />

Blue Seal PTFE Septa—10mil 95215 95343 95215 95343 95215 95343<br />

Green Seal PTFE Septa—10mil 95217 95345 95217 95345 95217 95345<br />

Yellow Seal PTFE Septa—10mil 95219 95347 95219 95347 95219 95347<br />

Clear Seal PTFE/Butyl Septa 95232 95332 95232 95332 95232 95332<br />

Red Seal PTFE/Butyl Septa 95235 95349 95235 95349 95235 95349<br />

Blue Seal PTFE/Butyl Septa 95237 95351 95237 95351 95237 95351<br />

Green Seal PTFE/Butyl Septa 95239 95353 95239 95353 95239 95353<br />

Yellow Seal PTFE/Butyl Septa 95233 95355 95233 95355 95233 95355<br />

Clear Seal PTFE/Silicone Septa 95234 95334 95234 95334 95234 95334<br />

Red Seal PTFE/Silicone Septa 95293 95224 95293 95224 95293 95224<br />

Blue Seal PTFE/Silicone Septa 95295 95225 95295 95225 95295 95225<br />

Green Seal PTFE/Silicone Septa 95297 95226 95297 95226 95297 95226<br />

Yellow Seal PTFE/Silicone Septa 95285 95227 95285 95227 95285 95227<br />

Clear Seal PTFE/Silicone/PTFE Septa 95236 95336 95236 95336 95236 95336<br />

Red Seal PTFE/Silicone/PTFE Septa 95310 95164 95310 95164 95310 95164<br />

Blue Seal PTFE/Silicone/PTFE Septa 95312 95166 95312 95166 95312 95166<br />

Green Seal PTFE/Silicone/PTFE Septa 95316 95182 95316 95182 95316 95182<br />

Yellow Seal PTFE/Silicone/PTFE Septa 95318 95184 95318 95184 95318 95184<br />

4712<br />

12x32mm Crimp Style Wide Mouth Specifications<br />

32mm<br />

12mm<br />

Neck Style: Crimp Top<br />

Recommended Closure:<br />

11mm Aluminum Caps, p358<br />

Optional Closures:<br />

11mm Poly Crimp Seals<br />

Neck Style:<br />

Snap Seal<br />

Recommended Closure:<br />

11mm Poly Crimp Seals<br />

Optional Closures:<br />

11mm Snap TOP Caps, p360<br />

11mm Aluminum Caps, p358<br />

Wide Mouth Opening (for both):<br />

11mm o.d., 6mm i.d.<br />

12mm<br />

32mm<br />

vials<br />

www.discoverysciences.com<br />

359


general chromatography<br />

12x32mm Crimp Style Wide Mouth Vials<br />

Snap Ring<br />

• 40% larger opening aids in sample<br />

transfers<br />

• StepVial design precisely aligns insert<br />

and vial<br />

• Economical kits simplify ordering<br />

4714<br />

12x32mm Crimp Style Wide Mouth Specifications<br />

32mm<br />

12mm<br />

Neck Style: Snap Ring<br />

Recommended Closure:<br />

11mm Snap TOP Caps<br />

Optional Closures:<br />

11mm Aluminum Caps, p358<br />

11mm Poly Crimp Seals, p359<br />

Wide Mouth Opening:<br />

11mm o.d., 6mm i.d.<br />

vials<br />

With White<br />

Marking Spot<br />

With White Graduated<br />

Marking Spots<br />

100/pk 1000/pk 100/pk 1000/pk 100/pk 1000/pk<br />

Snap Ring Vials<br />

Clear 98030 98130 98033 98202 95421 95422<br />

Amber 98095 98195 98083 98205 95431 95432<br />

Snap Ring Limited Volume Vials<br />

300µL Glass Insert in Clear Glass Vial 98086 98238 — — — —<br />

750µL Polypropylene Vial 98050 98215 — — — —<br />

750µL TPX (PMP) Vial 72015 72017 — — — —<br />

500µL Polypropylene Vial 98842 98844 — — — —<br />

500µL TPX (PMP) Vial 72011 72014 — — — —<br />

100µL Polypropylene Vial 12960 12961 — — — —<br />

100µL TPX (PMP) Microvial 12968 12969 — — — —<br />

200µL Glass Insert in Clear Vial 98230 98231 — — — —<br />

200µL Glass Insert in Amber Vial 98235 98236 — — — —<br />

Snap Ring Kits:<br />

Vials Caps with Septa<br />

Clear Vials 11mm Snap TOP Caps PTFE/Silicone Septa with Slit 98465 98467 — — — —<br />

Clear Vials 11mm Snap TOP Caps PTFE/Silicone Septa with Starburst 98469 98471 — — — —<br />

Clear Vials 11mm Snap TOP Caps PTFE/Butyl Septa 98473 98477 — — — —<br />

Clear Vials 11mm Snap TOP Caps PTFE/Silicone Septa 98483 98485 — — — —<br />

Amber Vials 11mm Snap TOP Caps PTFE/Butyl Septa 98479 98481 — — — —<br />

Amber Vials 11mm Snap TOP Caps PTFE/Silicone Septa 98487 98489 — — — —<br />

11mm Snap TOP Caps<br />

with Septa<br />

Clear Cap PTFE/Silicone Septa with Slit 98168 98268 98168 98268 98168 98268<br />

Clear Cap PTFE/Silicone Septa with Starburst 98252 98255 98252 98255 98252 98255<br />

Clear Cap PTFE/Silicone/PTFE Septa with Starburst 98257 98259 98257 98259 98257 98259<br />

Clear Cap Red Fluoroelastomer Polymer Septa 98223 98243 98223 98243 98223 98243<br />

Clear Cap PTFE Septa—10mil 98032 98442 98032 98442 98032 98442<br />

Red Cap PTFE Septa—10mil 98332 98333 98332 98333 98332 98333<br />

Blue Cap PTFE Septa—10mil 98334 98335 98334 98335 98334 98335<br />

Green Cap PTFE Septa—10mil 98336 98337 98336 98337 98336 98337<br />

Yellow Cap PTFE Septa—10mil 98338 98339 98338 98339 98338 98339<br />

Clear Cap PTFE/Silicone Septa—10mil 98034 98444 98034 98444 98034 98444<br />

Red Cap PTFE/Silicone Septa—10mil 98340 98341 98340 98341 98340 98341<br />

Blue Cap PTFE/Silicone Septa—10mil 98342 98343 98342 98343 98342 98343<br />

Green Cap PTFE/Silicone Septa—10mil 98344 98345 98344 98345 98344 98345<br />

Yellow Cap PTFE/Silicone Septa—10mil 98346 98347 98346 98347 98346 98347<br />

Clear Cap PTFE/Silicone/PTFE Septa—40mil 98036 98446 98036 98446 98036 98446<br />

Red Cap PTFE/Silicone/PTFE Septa—40mil 98348 98349 98348 98349 98348 98349<br />

Blue Cap PTFE/Silicone/PTFE Septa—40mil 98350 98351 98350 98351 98350 98351<br />

Green Cap PTFE/Silicone/PTFE Septa—40mil 98352 98353 98352 98353 98352 98353<br />

Yellow Cap PTFE/Silicone/PTFE Septa—40mil 98354 98355 98354 98355 98354 98355<br />

Clear Cap PTFE/Butyl Rubber Septa—40mil 98038 98448 98038 98448 98038 98448<br />

Red Cap PTFE/Butyl Rubber Septa—40mil 98356 98357 98356 98357 98356 98357<br />

Blue Cap PTFE/Butyl Rubber Septa—40mil 98358 98359 98358 98359 98358 98359<br />

Green Cap PTFE/Butyl Rubber Septa—40mil 98362 98363 98362 98363 98362 98363<br />

Yellow Cap PTFE/Butyl Rubber Septa—40mil 98364 98365 98364 98365 98364 98365<br />

Clear Cap Polyethylene Septa—10mil 98170 98270 98170 98270 98170 98270<br />

11mm GC Snap TOP Caps<br />

with Septa<br />

Clear Cap PTFE/Red Butyl Septa 88351 88364 88351 88364 88351 88364<br />

Clear Cap PTFE/Silicone Septa 88359 88367 88359 88367 88359 88367<br />

Clear Cap PTFE/Silicone/PTFE Septa 88362 88469 88362 88469 88362 88469<br />

more info<br />

GC Snap TOP Caps provide better seal<br />

for volatile samples.<br />

related products<br />

Looking for crimping tools?<br />

Refer to page 383.<br />

360 www.discoverysciences.com


general chromatography<br />

Limited Volume Inserts for 12x32mm Vials<br />

• Select the appropriate limited volume insert for your<br />

microsampling needs<br />

• Polyethylene springs act as shock adsorbers and<br />

help to maintain proper insert alignment<br />

• Flange step inserts align precisely in StepVial<br />

design neck<br />

Limited Volume Inserts for Standard Mouth Vials (4mm i.d.)<br />

Description<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Glass<br />

100µL, No Spring 95201 95202<br />

100µL, with Polyethylene Bottom Spring 98031 98131<br />

50µL, with Polyethylene Bottom Spring 98018 98058<br />

50-100µL, Requires Spring 95203 95204<br />

Metal Springs for (95203) 95205 95206<br />

250µL, Flat Bottom 98028 98128<br />

100µL, Silanized, No Spring Required 952018 —<br />

Polypropylene<br />

100µL, No Spring 98137 98237<br />

100µL, with Polyethylene Bottom Spring 98069 98169<br />

250µL, Flat Bottom, 5x31mm 99176 99179<br />

Glass for Screw Thread 4mm i.d. Only<br />

100µL, with Polyethylene Top Flange 98107 98117<br />

4747<br />

Vial Adapter<br />

For Use with Waters ® Alliance ® Autosampler<br />

• Reuseable adapter<br />

• Adds versatility to use of your Waters ® 717 and Alliance ®<br />

autosamplers<br />

Limited Volume Inserts for Wide Mouth Vials (6mm i.d.)<br />

Description<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Glass<br />

250µL, No Spring 98322 98324<br />

250µL, Glass Flange Step Insert 98745 98755<br />

50µL, with Polyethylene Bottom Spring 98024 98064<br />

100µL, with Polyethylene Top Spring 98052 98452<br />

250µL, with Polyethylene Bottom Spring 98049 98449<br />

400µL, Flat Bottom 981391 98439<br />

250µL, Silanized 983228 —<br />

250µL, Silanized with Polyethylene Bottom Spring 99060 —<br />

Polypropylene<br />

100µL, with Polyethylene Top Spring 92102 98402<br />

250µL, with Polyethylene Bottom Spring 98108 98408<br />

250µL, No Spring Required 98106 98406<br />

250µL, Polyethylene Flange Step Insert 98729 98739<br />

350µL, Flat Bottom, 6x30mm 99183 99189<br />

Prepare samples in one 8x30mm vial and analyze using<br />

either the Waters ® WISP 96 or Alliance ® autosampler trays.<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

5222<br />

Vial Adapter for Waters ® Alliance ® Autosampler<br />

Description<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Reuseable Adapter for Alliance ® 12x32mm Autosampler Tray<br />

Adapter for Use of 8x30mm Vials in a 12x32mm 98374* —<br />

Tray, 24/pkg<br />

Kits —Vials and Caps for Use with Waters ® 717 or Alliance ® Autosamplers<br />

8x30mm Shell Vials, 8mm Clear Starburst<br />

98100 98360<br />

Snap Plugs<br />

Vials and Caps for Use with Waters ® 717 or Alliance ® Autosamplers<br />

8x30mm Shell Vials, Clear Glass 97029 98037<br />

8x30mm Polypropylene Shell Vial, 900µL 99184 99192<br />

8x30mm Polypropylene LV Shell Vial, 500µL 99178 99182<br />

8mm Clear Starburst Snap Plugs 88613 98865<br />

Vials and 10/425 Caps for Waters ® Alliance ® Autosamplers<br />

12x32mm Clear Wide Mouth Vials 98133 98433<br />

12x32mm Amber Wide Mouth Vials 98135 98435<br />

Black Polypropylene Caps, PTFE/Silicone Septum, 98144 98152<br />

60mil<br />

*Correct quantity specified in description.<br />

vials<br />

www.discoverysciences.com<br />

361


general chromatography<br />

vials<br />

15x45mm Screw Thread Vials<br />

• Compatible with Waters ® WISP<br />

48 position, 717, Breeze and<br />

Shimadzu ® autosamplers<br />

• Use for waste/wash vials for other<br />

autosamplers<br />

• 13/425 open top caps and septa<br />

• StepVial design precisely aligns insert<br />

and vial<br />

• Economical kits simplify ordering<br />

Silanized<br />

With White<br />

Marking Spot<br />

With White Graduated<br />

Marking Spots<br />

100/pk 1000/pk 100/pk 100/pk 1000/pk 100/pk 1000/pk<br />

Vials<br />

Clear 98110 98207 981101 98241 98247 97084 97088<br />

Amber 98120 98484 981201 98261 98267 97097 97117<br />

Limited Volume Vials<br />

3.1mL Glass High Recovery Vial 72018 — — — — — —<br />

1.2mL Polypropylene Limited Volume Vial 70149 70198 — — — — —<br />

2.5mL Polypropylene Vial 98091 98491 — — — — —<br />

300µL Plastic Vial with Glass Insert 98251 98253 — — — — —<br />

Preassembled Kits:<br />

Vials Caps with Septa<br />

Clear Vials Open-Hole Caps PTFE Septa—10mil 98000 98002 — — — — —<br />

Amber Vials Open-Hole Caps PTFE Septa—10mil 98004 98006 — — — — —<br />

Clear Vials Open-Hole Caps PTFE/Silicone Septa—10/50mil 98008 98012 72676 — — — —<br />

Amber Vials Open-Hole Caps PTFE/Silicone Septa—10/50mil 98014 98016 72680 — — — —<br />

Clear Vials Open-Hole Caps PTFE/Silicone/PTFE Septa 98549 98551 — — — — —<br />

Amber Vials Open-Hole Caps PTFE/Silicone/PTFE Septa 98618 98621 — — — — —<br />

Clear Vials Open-Hole Caps PTFE/Butyl Septa—40mil 98623 98626 — — — — —<br />

Amber Vials Open-Hole Caps PTFE/Butyl Septa—40mil 98628 98630 — — — — —<br />

Clear Vials Open-Hole Caps TOP Hat Septa—65mil 98633 98632 — — — — —<br />

Limited Volume Inserts<br />

250µL Flange Step Glass Insert 70205 70215 — 70205 70215 70205 70215<br />

275µL 7x44mm Polypropylene LV Insert 99165 99180 — 99165 99180 99165 99180<br />

300µL 6x38mm Glass Insert, Requires Metal Spring 98118 98218 — 98118 98218 98118 98218<br />

300µL 6x38mm Polypropylene Insert, Requires Metal Spring 98071 98271 — 98071 98271 98071 98271<br />

Metal Springs for 300µL Inserts 98121 98221 — 98121 98221 98121 98221<br />

300µL Self Centering Glass Top Spring 98056 98256 — 98056 98256 98056 98256<br />

300µL Self Centering Polyethylene Top Spring 92104 98204 — 92104 98204 92104 98204<br />

300µL Self Centering Glass Bottom Spring 98199 98299 — 98199 98299 98199 98299<br />

300µL Self Centering Polyethylene Bottom Spring 98193 98293 — 98193 98293 98193 98293<br />

300µL Silanized Glass Insert — — 981188 — — — —<br />

350µL Flange Step Glass Insert 98942 98944 — 98942 98944 98942 98944<br />

500µL 8x43mm Glass Flat Bottom Insert 98581 98583 — 98581 98583 98581 98583<br />

Preassembled 13/425<br />

Open-Hole Caps<br />

with Septa<br />

Black Cap Bonded Interseal PTFE/Silicone Septa 70420 70424 — 70420 70424 70420 70424<br />

Black Cap PTFE/Silicone Septa with Slit—60mil 97017 97027 — 97017 97027 97017 97027<br />

Black Cap PTFE/Silicone Septa—65mil 98610 98612 — 98610 98612 98610 98612<br />

Black Cap PTFE/Silicone/PTFE Septa 98735 98737 — 98735 98737 98735 98737<br />

Black Cap PTFE/Silicone TOP Hat Septa 98075 98475 — 98075 98475 98075 98475<br />

Clear Cap TOP Seal Closure with Molded Septa—10mil 98070 98480 — 98070 98480 98070 98480<br />

Solid 13/425 TOP Caps with Septa<br />

Solid Green Phenolic Cap with PTFE Septa 98209 98476 — 98209 98476 98209 98476<br />

Solid White Cap with Interseal PTFE/Silicone Bonded Septa 99031 — — 99031 — 99031 —<br />

Solid Black Cap with PTFE/F217 Septa 98430 98432 — 98430 98432 98430 98432<br />

Solid Black Cap 98614 98616 — 98614 98616 98614 98616<br />

Unlined 13/425 Caps<br />

Black Cap 73090 73092 — 73090 73092 73090 73092<br />

Red Cap 98454 98466 — 98454 98466 98454 98466<br />

Blue Cap 98456 98468 — 98456 98468 98456 98468<br />

Green Cap 98458 98470 — 98458 98470 98458 98470<br />

Yellow Cap 98460 98472 — 98460 98472 98460 98472<br />

White Cap 98462 98474 — 98462 98474 98462 98474<br />

Septa for 13/425 Caps<br />

PTFE—10mil 73094 73096 — 73094 73096 73094 73096<br />

PTFE/Silicone with Slit—5/55mil 98164 98464 — 98164 98464 98164 98464<br />

PTFE/Butyl Rubber—5/55mil 98367 98369 — 98367 98369 98367 98369<br />

Red PTFE/Silicone—5/55mil 98846 98848 — 98846 98848 98846 98848<br />

PTFE/White Silicone—10/50mil 98123 98450 — 98123 98450 98123 98450<br />

PTFE/White Silicone—10/90mil 98219 95248 — 98219 95248 98219 95248<br />

PTFE/Silicone/PTFE—2/36/2mil 98280 98282 — 98280 98282 98280 98282<br />

Black Fluoroelastomer Polymer—30mil 98606 98608 — 98606 98608 98606 98608<br />

4716<br />

15x45mm Screw Thread Specifications<br />

45mm<br />

15mm<br />

Neck Style: Screw Thread<br />

Required Closure:<br />

13/425 Screw Thread Caps<br />

362 www.discoverysciences.com


general chromatography<br />

15x45mm Crimp Style Vials<br />

• Compatible with Waters ® WISP<br />

48 position, 717 and Shimadzu ®<br />

autosamplers<br />

• Use for waste/wash vials for other<br />

autosamplers<br />

• Economical kits simplify ordering<br />

15x45mm Crimp Style Vial Specifications<br />

45mm<br />

Neck Style:<br />

Snap Ring<br />

Neck Style:<br />

Snap Seal<br />

Recommended Closure:<br />

13mm Snap TOP Caps<br />

13mm Aluminum Seals<br />

45mm<br />

With White Graduated<br />

Marking Spots<br />

100/pk 1000/pk 100/pk 1000/pk<br />

Snap Seal Vials, 4mL<br />

Clear 98040 98240 95545 95546<br />

Amber 98097 98297 95547 95548<br />

Snap Ring Limited Volume Vials<br />

300µL Plastic Vial with Glass Insert 98154 98156 — —<br />

2.5mL Polypropylene Vial 98054 98254 — —<br />

Unassembled Kits:<br />

Snap Seal Vials Caps with Septa<br />

Clear Vials 13mm Snap TOP Caps PTFE Septa—10mil 98390 98392 — —<br />

Clear Vials 13mm Snap TOP Caps PTFE/Silicone Septa 98874 98876 — —<br />

Amber Vials 13mm Snap TOP Caps PTFE/Silicone Septa 98870 98872 — —<br />

Clear Vials 13mm Snap TOP Caps PTFE/Butyl Septa 98636 98638 — —<br />

Amber Vials 13mm Snap TOP Caps PTFE/Butyl Septa 98640 98644 — —<br />

Clear Vials 13mm Snap TOP Caps PTFE/Silicone/PTFE Septa 98646 98648 — —<br />

Unassembled Kits:<br />

Snap Seal Vials Seals with Septa<br />

Clear Vials Caps PTFE/Silicone Septa 98132 98269 — —<br />

Clear Vials Caps PTFE/Butyl Septa 98145 97266 — —<br />

Clear Vials Caps PTFE/Silicone/PTFE Septa 98147 97273 — —<br />

Limited Volume Inserts<br />

250µL Flange Step Glass Insert 70205 70215 70205 70215<br />

275µL 7x44mm Polypropylene LV Insert 99165 99180 99165 99180<br />

300µL 6x38mm Glass Insert, Requires Metal Spring 98118 98218 98118 98218<br />

300µL 6x38mm Polypropylene Insert, Requires Metal Spring 98071 98271 98071 98271<br />

Metal Springs for 300µL Inserts 98121 98221 98121 98221<br />

300µL Self Centering Glass Top Spring 98056 98256 98056 98256<br />

300µL Self Centering Polyethylene Top Spring 92104 98204 92104 98204<br />

300µL Self Centering Glass Bottom Spring 98199 98299 98199 98299<br />

300µL Self Centering Polyethylene Bottom Spring 98193 98293 98193 98293<br />

350µL Flange Step Glass Insert 98942 98944 98942 98944<br />

500µL 8x43mm Glass Flat Bottom Insert 98581 98583 98581 98583<br />

13mm Snap TOP Caps<br />

with Septa<br />

Clear Cap PTFE Septa—10mil 98042 98242 98042 98242<br />

Clear Cap PTFE/Silicone Septa 98044 98244 98044 98244<br />

Clear Cap PTFE/Silicone/PTFE Septa 98046 98246 98046 98246<br />

Clear Cap PTFE/Butyl Rubber Septa 98048 98248 98048 98248<br />

Clear Cap PTFE/Silicone Septa with Starburst 98586 98588 98586 98588<br />

Clear Cap PTFE/Silicone/PTFE Septa with Starburst 98593 98594 98593 98594<br />

13mm Aluminum Seals<br />

with Septa<br />

Silver Seal PTFE Septa—10mil 98101 98103 98101 98103<br />

Silver Seal PTFE/Silicone Septa 98283 98289 98283 98289<br />

Silver Seal White PTFE/Butyl Septa 98776 98206 98776 98206<br />

Silver Seal PTFE/Silicone/PTFE Septa 98596 98598 98596 98598<br />

Gold Seal Pharma-Fix Septa 6687 98208 6687 98208<br />

13mm Aluminum Seals, Unlined<br />

Silver Seal, Center Tear Off 98778 66410 98778 66410<br />

Red Seal, Center Tear Off 98780 — 98780 —<br />

Blue Seal, Center Tear Off 98783 — 98783 —<br />

Green Seal, Center Tear Off 98785 — 98785 —<br />

Gold Seal, Center Tear Off 98787 — 98787 —<br />

Silver Seal, Tear-Away 98789 66416 98789 66416<br />

13mm Septa for Aluminum Seals<br />

White PTFE—10mil 98177 — 98177 —<br />

PTFE/Silicone—10/50mil 98791 95253 98791 95253<br />

PTFE/Silicone—10/90mil 98793 95254 98793 95254<br />

PTFE/Silicone/PTFE—2/36/2mil 98180 98182 98180 98182<br />

PTFE/Butyl Rubber—40mil 98173 98175 98173 98175<br />

4717<br />

15mm<br />

15mm<br />

vials<br />

www.discoverysciences.com<br />

363


general chromatography<br />

Headspace Vials<br />

• Crimp style vials, made of<br />

borosilicate glass<br />

• New screw thread headspace vial<br />

• Five finish styles available<br />

• Choose from three vial sizes,<br />

6, 10, or 20mL<br />

For reproducible results, it’s very important<br />

that the headspace vials and caps form a<br />

tight seal. In headspace analysis, the sample<br />

is sealed into the vial and heated until the<br />

concentration in the gas phase (headspace)<br />

is in equilibrium with the concentration in the<br />

liquid phase. An aliquot from the headspace<br />

is then analyzed.<br />

Shimadzu ® HSS-2B<br />

30x60mm<br />

27mL<br />

4726<br />

Vials for Tekmar ®<br />

4725<br />

Flat Top,<br />

Flat Bottom<br />

20mL<br />

Headspace Vials<br />

4725<br />

Flat Top,<br />

Round Bottom,<br />

Long Neck, 20mL<br />

4725<br />

Bevel Top,<br />

Flat Bottom<br />

20mL<br />

4725<br />

Bevel Top,<br />

Round Bottom<br />

20mL<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Description<br />

Flat Top, Flat Bottom, Clear Glass, Long Neck<br />

22.5x75.5mm, 20mL Vials 6636 66361<br />

22.5x46mm, 10mL Vials 6655 66551<br />

Flat Top, Round Bottom, Clear Glass<br />

22.5x75.5mm, 20mL Vials for CTC PAL, Long Neck 97188 97190<br />

22.5x75.5mm, 20mL Vials, for SPME** 99097 99099<br />

Bevel Top, Flat Bottom, Clear Glass<br />

23x75mm, 20mL Vials 99136 99138<br />

23x46mm, 10mL Vials 98792 98794<br />

22x38mm, 6mL Vials 99132 99134<br />

Bevel Top, Round Bottom<br />

23x75.5mm, 20mL Vials, Clear 98788 98790<br />

23x75.5mm, 20mL Vials, Amber 99077 99093<br />

22.5x46mm, 10mL Vials, Clear 98938 98676<br />

22x38.25mm, 5mL Vials, Clear 99056 99058<br />

Shimadzu ® Headspace Vials<br />

30x60mm, 27mL, Clear Vials 98093 98546<br />

Tekmar ® Headspace Vials<br />

18x50mm, 9mL, Clear Vials, 125/pk 98098* 98548<br />

18x65mm, 12mL, Clear Vials, 125/pk 98104* 98877<br />

23x75.5mm, 20mL, Clear Vials 95128 95137<br />

Screw Thread Headspace Vials for CTC PAL***<br />

20mL Clear 99065 99069<br />

20mL Amber 99068 99074<br />

10mL Clear 99070 99072<br />

10mL Amber 99078 99075<br />

*Correct quantity specified in description.<br />

**SPME vial has thicker glass top so cap with thinner septum will crimp tightly.<br />

***New units only. Older models have weak magnets.<br />

6755<br />

Screw Top,<br />

Flat Bottom,<br />

20mL<br />

Cross Reference of Headspace Vials to Autosamplers<br />

Instrument manufacturers recommend use of various vial shapes for best<br />

results with their analytical systems so we offer all of the vial shapes available.<br />

vials<br />

18x50mm<br />

9mL<br />

18x65mm<br />

12mL<br />

4727<br />

4725<br />

Bevel Top,<br />

Round Bottom<br />

20mL<br />

Headspace Vials** and Corresponding Autosamplers<br />

Recommended For Autosampler Part No. Vial Description<br />

PerkinElmer ® HS6 99056 5mL Bevel Top/Bound Bottom<br />

Carlo Erba HS250/HS800; CTC500;<br />

98938 10mL Bevel Top/Round Bottom<br />

Fisons HS500/HS800; Chrompack 9020/25<br />

PerkinElmer ® HS40/HS100/101 98788 20mL Bevel Top/Round Bottom<br />

Tekmar ® 7000 Series 95128 20mL Bevel Top/Round Bottom<br />

CTC PAL 97188 20mL Flat Top/Round Bottom<br />

Carlo Erba HS850; Dani HS86.50/HS39.5; 6655,6636 10mL, 20mL Flat Top/Flat Bottom<br />

Fisons HS850; Hewlett-Packard HS 7694<br />

SPME 99097 20mL, Magnetic Cap<br />

Shimadzu ® 98093 27mL, 30x60mm<br />

CTC PAL, Gerstel 99065/99070<br />

99065/99070<br />

Screw Thread Magnetic Cap<br />

Screw Thread Magnetic Cap<br />

**This list is only a guide to the most popular vial and autosampler combinations. Many instruments will<br />

allow use of other combinations of flat or beveled tops with flat or rounded bottoms. If a particular type of<br />

vial is required for your instrument, the information should be provided by your autosampler or instrument<br />

manufacturer.<br />

364 www.discoverysciences.com


general chromatography<br />

20mm Seals and Septa for Headspace Vials<br />

• Increased selection of septa in aluminum, pressure release (PR), or magnetic seals<br />

• Now available in convenience kits with headspace vials and pressure release caps<br />

20mm Polyethylene Seal<br />

Low cost, polyethylene seal for<br />

rinse vials or low pressure analysis.<br />

No crimping is required.<br />

Types of Aluminum Seals<br />

Center Hole<br />

Center Tear-Off<br />

Magnetic Caps<br />

Types of Septa<br />

4998<br />

4999 5001<br />

5002 5003<br />

5000<br />

5005<br />

Aluminum Faced/Silicone<br />

Stoppers<br />

5mm Center Hole<br />

5007<br />

PTFE Faced/Butyl Molded Septum<br />

(Pharma-Fix Septum)<br />

Pressure Release (PR)<br />

Tear-Away<br />

4999<br />

8mm Center Hole<br />

5006<br />

Silicone or PTFE/Silicone<br />

20mm Seals and Septa for Headspace Vials<br />

Description Qty. Part No. Qty. Part No.<br />

Polyethylene Seal<br />

with PTFE/Silicone Septum—5/45mil 100 95586 1000 95576<br />

Aluminum Seals, Open Center Hole with Septa<br />

Seal, PTFE/Butyl Rubber Septum 100 98801 500 98552<br />

Seal, PTFE/Silicone Septum— 100 95756 1000 95758<br />

10/50mil<br />

Seal, PTFE/Silicone Septum—125mil 100 95587 1000 95577<br />

Seal, PTFE/Chlorobutyl Septum 100 95584 1000 95578<br />

Seal, Aluminum/Silicone Septum 100 98687 1000 98689<br />

Seal, Black Butyl Rubber Septum 100 98683 1000 98685<br />

Center Tear-Off Seal, Butyl Septum 72 98841 10x72 98550<br />

Specialty Seals with Septa<br />

Seal with Pharma-Fix Septum 100 6689 1000 98898<br />

PR Seal, PTFE/Silicone Septum— 100 95581 1000 95579<br />

118mil<br />

PR Seal, PTFE/Gray Butyl Septum— 100 95590 1000 95580<br />

118mil<br />

PR Seal, Aluminum/Silicone<br />

100 98691 1000 98693<br />

Septum—118mil<br />

Magnetic*, 5mm Center, PTFE/ 100 95594 1000 95588<br />

Silicone Septum—118mil<br />

Magnetic*, 8mm Center, PTFE/ 100 95139 1000 95143<br />

Silicone Septum—118mil,<br />

Magnetic*, 5mm Center, PTFE/Gray 100 95592 1000 95582<br />

Butyl Septum—118mil<br />

Magnetic*, 8mm Center, PTFE/Gray 100 95156 1000 95189<br />

Butyl Septum—118mil<br />

Magnetic Seal for SPME Vial, PTFE/ 100 99102 1000 99106<br />

Silicone Septum 1.5mm<br />

Magnetic Seal for SPME,<br />

100 99104 1000 99107<br />

Fluoroelastomer Polymer Septum,<br />

1.0mm<br />

Aluminum Seals without Septa<br />

Standard Seals, 10mm Center Hole 144 66381 1000 89075<br />

Tear-Away Seals, Silver 144 66501 10x144 98805<br />

Silver, Center Tear-Off Seal 144 66440 10x144 98803<br />

Red, Center Tear-Off Seal 144 66441 10x144 66418<br />

Blue, Center Tear-Off Seal 144 66442 10x144 66419<br />

Green, Center Tear-Off Seal 144 66443 10x144 66425<br />

Gold, Center Tear-Off Seal 144 66444 10x144 66426<br />

Magnetic Tinplate Seal*, 5mm Center 100 98532 1000 98534<br />

Septa for 20mm Aluminum Seals<br />

Red Butyl Septum 100 98695 1000 98697<br />

Red Silicone Septum 72 98536 10x72 98538<br />

PTFE/Silicone Septum—10/90mil 72 95313 10x72 98809<br />

PTFE/Gray Butyl Septum 72 98540 10x72 98542<br />

Aluminum Faced/Silicone—60mil 72 98665 10x72 98667<br />

Stoppers for 20mm Crimp Top Vials<br />

Natural Rubber Stoppers 72 95304 1000 95255<br />

Butyl Rubber Stoppers 72 95305 1000 95256<br />

Hycar Rubber Stoppers 72 6683 10x72 98813<br />

Magnetic Screw Thread Caps with Septa for Screw Thread Headspace Vials<br />

White PTFE/Blue Silicone Septum, 100 99071 1000 99081<br />

1.3mm<br />

PTFE/ Red Butyl Septum, 1.6mm 100 99073 1000 99083<br />

Blue PTFE/White Silicone Septum, 100 99076 1000 99091<br />

1.5mm<br />

Fluoroelastomer Polymer, 1.0mm 100 99079 1000 99086<br />

*Magnetic Seals are used with CTC and Carlo Erba autosamplers.<br />

vials<br />

4766<br />

www.discoverysciences.com<br />

365


general chromatography<br />

Specialty Autosampler Vials<br />

8x40mm<br />

7x32mm<br />

4718<br />

Shimadzu ®<br />

ASI-5000<br />

4722<br />

8x30mm<br />

7x40mm<br />

DuPont ®<br />

Vials<br />

4719<br />

4720<br />

Specialty Autosampler Vials<br />

Description Qty. Part No. Qty. Part No.<br />

8x40mm WISP Crimp Style Vials (Use 8mm Closures Below)<br />

1.0mL Clear Vial 125 98799 1000 98035<br />

1.0mL Clear Taper Vial 500 97269 1000 98496<br />

8x30mm Crimp Top Vials (Use 8mm Closures Below)<br />

0.5mL Clear, Flat Bottom 200 98819 1000 98823<br />

0.5mL Amber, Tapered Bottom — — 500 97260<br />

Sleeve for Tapered Vial (98183) 50 98146 — —<br />

7x32mm Crimp Top Vials (Use 8mm Closures Below)<br />

500µL Amber, Tapered Bottom — — 500 97264<br />

700µL Amber, Round Bottom 125 98403 500 98411<br />

Sleeve for 7x32mm Vials 40 98415 — —<br />

7x40mm Crimp Top Vials (Use 8mm Closures Below)<br />

700µL Clear, Tapered Bottom 125 98148 1000 98150<br />

700µL Amber, Tapered Bottom 200 98894 1000 95171<br />

800µL Clear, Flat Bottom 200 98043 1000 98045<br />

800µL Amber, Flat Bottom 200 98896 1000 95170<br />

6x32mm Crimp Top Vials (not shown) (Use 8mm Closures Below)<br />

6x32mm Tapered, 0.2mL 100 94470 1000 94472<br />

6x32mm Round, 0.3mL 100 94450 1000 94463<br />

Black Support Sleeve for<br />

20 94455 — —<br />

HP1090A<br />

White Support Sleeve for HP1050, 20 94460 — —<br />

7673A<br />

Miscellaneous Vials, Clear Glass (not shown) (Use 11mm Seals)<br />

12x40mm, Use 11mm Seal 100 98273 1000 98570<br />

10x32, 0.9mL, Use 11mm Seal 500 98226 5x200 98572<br />

Support Sleeve for 98226 100 98217 — —<br />

Alcott Micromeritics Vials (not shown)<br />

8x35mm, Clear Shell Vial with 200 98903 1000 50303400<br />

Plugs, 1mL<br />

Shimadzu ® Autosampler Vials and Tubes<br />

Vial, 12x96mm, 5mL, 10/425 100 98187 1000 98564<br />

Threads<br />

Tube, 12x96mm, 5mL, No Cap 100 98375 1000 98379<br />

Required<br />

DuPont ® Autosampler Vials (Use 13/425 Screw Cap)<br />

13x65mm, 4mL, 13/425 Threads 125 98821 8x125 98566<br />

13x100mm, 8mL, 13/425 Threads 125 98250 8x125 98568<br />

4mL<br />

vials<br />

5mL<br />

Vial<br />

8mm Closures<br />

5mL<br />

Tube<br />

4723 4724<br />

8mL<br />

Aluminum Seals<br />

with Septa<br />

4743 4744<br />

Polypropylene<br />

Snap Seal<br />

8mm Closures<br />

Description Qty. Part No. Qty. Part No.<br />

Aluminum Seals with Septum<br />

Silver Seal with PTFE/Butyl Rubber 100 94831 1000 95172<br />

Septum<br />

Silver Seal with PTFE/Silicone Septum 100 94832 1000 94833<br />

Silver Seal with PTFE/Silicone/PTFE 100 94251 1000 94253<br />

Septum<br />

Silver Seal with Black Fluoroelastomer 100 94834 1000 94835<br />

Polymer Septum—50mil<br />

Polypropylene Snap Seal 100 83122 1000 83130<br />

366 www.discoverysciences.com


general chromatography<br />

Silanized Glassware<br />

4711<br />

Silanized Vials<br />

Description Qty. Part No.<br />

12x32mm Vials<br />

Clear, Standard Mouth, 4mm i.d., 8/425 Thread 100 951911<br />

Amber, Standard Mouth, 4mm i.d., 8/425 Thread 100 951941<br />

Clear, Wide Mouth, 6mm i.d., 10/425 Thread 100 981331<br />

Amber, Wide Mouth, 6mm i.d., 10/425 Thread 100 981351<br />

Clear, R.A.M. Robotic, 6mm i.d., 9mm Thread 100 953861<br />

Amber, R.A.M. Robotic, 6mm i.d., 9mm Thread 100 953881<br />

8x40mm Shell Vials<br />

Clear 100 886101<br />

15x45mm Vials<br />

Clear, 13/425 Thread 100 981101<br />

Amber, 13/425 Thread 100 981201<br />

more info<br />

See individual product pages for a complete listing of closure<br />

options.<br />

tech tip<br />

Use of silanized glassware can often improve the separations<br />

of polar compounds such as antibodies, amines, pesticides,<br />

phenols, and proteins. Pharmaceutical compounds in solution and<br />

metabolites are especially sensitive and often absorb to the walls<br />

of an untreated glass container destroying any quantitative value<br />

the solution might have.<br />

Our HMDS, high temperature silanization process eliminates<br />

active sites and prevents sample loss or degradation.<br />

Silanized Inserts and Specialty Vials<br />

Description Qty. Part No.<br />

Limited Volume Inserts for Vials<br />

100µL for 12x32 Standard Mouth 100 952018<br />

250µL for 12x32 Wide Mouth 100 983228<br />

250µL with PE Bottom Spring for Wide Mouth 100 99060<br />

100µL for 1mL WISP 96 Style Vials, 8x40 100 989008<br />

300µL for 15x45 WISP Style Vials 100 981188<br />

Silanized Culture Tubes<br />

13x100mm Culture Tubes 1000 985911<br />

10x75mm Culture Tubes 1000 985901<br />

12x75mm Culture Tubes 1000 985871<br />

16x100mm Culture Tubes 1000 985951<br />

Special Silanized Vials<br />

300µL Crimp Top Microvials, 8mm Seals with<br />

PTFE/Butyl Septa<br />

100 944508<br />

more info<br />

Convenience kits simplify ordering with one part number to<br />

remember. Kits provide both vials and caps for a perfect fit<br />

every time.<br />

best<br />

value<br />

4932<br />

Silanized Vial Kits<br />

Description Qty. Part No.<br />

12x32mm (2mL) Silanized Screw Cap Vial kits<br />

Clear, Standard Mouth Vials, 8/425 Caps,<br />

100 72666<br />

PTFE/Silicone Septa<br />

Amber, Standard Mouth Vials, 8/425 Caps,<br />

100 72670<br />

PTFE/Silicone Septa<br />

Clear, Wide Mouth Vials, 10/425 Caps,<br />

100 981338<br />

PTFE/Silicone Septa<br />

Amber, Wide Mouth Vials, 10/425 Caps,<br />

100 981358<br />

PTFE/Silicone Septa<br />

Clear, R.A.M. Robotic Vials, 9mm Caps,<br />

100 953868<br />

PTFE/Silicone Septa<br />

Amber, R.A.M. Robotic Vials, 9mm Caps,<br />

100 895388<br />

PTFE/Silicone Septa<br />

1mL WISP Style 96 Silanized Vial Kit<br />

Clear Vials with Clear Snap Plugs 100 982108<br />

15x45mm (4mL) Silanized Screw Thread Cap Vial Kits<br />

Clear Vials, 13/425 Caps, PTFE/Silicone Septa 100 72676<br />

Amber Vials, 13/425 Caps, PTFE/Silicone Septa 100 72680<br />

vials<br />

4741<br />

related products<br />

Custom Silanization Service<br />

Have we missed a vial or tube<br />

size that you need? Call to<br />

inquire about custom silanization<br />

for any vial or tube size that you<br />

need for your application, C-8500.<br />

www.discoverysciences.com<br />

367


general chromatography<br />

Screw Thread Vials and Storage Bottles<br />

Screw Cap Vials<br />

Boston Round Screw Cap Bottles<br />

4745<br />

Screw Cap Vials and Bottles for Sample Storage<br />

Glass<br />

Color<br />

Neck<br />

Finish<br />

Dia x Ht<br />

(mm) Qty. Part No. Qty. Part No.<br />

Volume<br />

Screw Cap Vials<br />

2mL Clear 8/425 12x32 100 95191 1000 95192<br />

2mL Amber 8/425 12x32 100 95194 1000 95195<br />

2mL Clear 10/425 12x32 100 98133 1000 98433<br />

2mL Amber 10/425 12x32 100 98135 1000 98435<br />

4mL Clear 13/425 15x45 100 98110 1000 98207<br />

4mL Amber 13/425 15x45 100 98120 1000 98484<br />

8mL Clear 15/425 17x60 144 98862* 200 988621<br />

8mL Amber 15/425 17x60 144 98864* 200 988641<br />

14–16mL Clear 18/400 21x70 144 98866* 200 988661<br />

14–16mL Amber 18/400 21x70 144 98186* — —<br />

24mL Clear 20/400 23x85 144 98868* 200 988681<br />

40mL Clear 24/400 28x95 100 98912 1000 98914<br />

Boston Round Screw Cap Bottles<br />

30mL–1oz Clear 20/400 31x79 12 9529 — —<br />

30mL–1oz Amber 20/400 31x79 12 9536 — —<br />

60mL–2oz Clear 20/400 39x94 12 9531 — —<br />

60mL–2oz Amber 20/400 39x94 12 9537 — —<br />

125mL–4oz Clear 22/400 48x112 12 9523 — —<br />

125mL–4oz Amber 22/400 48x112 12 9538 — —<br />

250mL–8oz Clear 24/400 60x136 12 9535 — —<br />

250mL–8oz Amber 24/400 60x136 12 9539 — —<br />

480mL–16oz Amber 28/400 75x168 12 95391 — —<br />

960mL–32oz Clear 33/400 94x206 12 95392 — —<br />

*Includes vials and caps with white styrene butadiene rubber septa.<br />

4746<br />

PTFE Septum Vials<br />

• Usable to 250°C<br />

• Ideal for alkaline reactions<br />

• Useful for silylation, acylation, alkylation, and<br />

hydrolysis reactions<br />

• Do not use as a pressure vessel<br />

Sampling Devices<br />

Volume Qty. Part No.<br />

PTFE Mini-Vials (Supplied with Caps and Septa)**<br />

5mL PFA Mini-Vials, 2.54x3.5cm 10 97050<br />

7mL PFA Mini-Vials, 2x3.4cm 10 97070<br />

15mL PFA Mini-Vials 10 97150<br />

30mL PFA Mini-Vials 10 97300<br />

23mm PTFE/Silicone Septum, Fit 5, 7mL 30 95363<br />

31mm PTFE/Silicone Septum, Fit 15, 30mL 30 95373<br />

24mm Mininert ® Valve, Fit 5, 7mL 12 95326<br />

**Vials are made of PTFE, a perfluoroalkoxy copolymer with properties similar to PTFE<br />

and FEP.<br />

related products<br />

Refer to pages 380–381 for racks<br />

and storage containers.<br />

vials<br />

more info<br />

For Screw Thread Closures see page 369.<br />

4951<br />

368 www.discoverysciences.com


general chromatography<br />

Screw Thread Closures<br />

Open-Hole Screw Thread Caps, Unlined<br />

Open-Hole Screw Thread Caps, Unlined<br />

Neck Finish Description Qty. Part No.<br />

Open-Hole Screw Caps, Unlined, Polypropylene<br />

8/425 Black Open-Hole Cap 100 73044<br />

8/425 Black Open-Hole Cap 1000 73059<br />

10/425 Black Open-Hole Cap 100 98143<br />

10/425 Black Open-Hole Cap 1000 98443<br />

13/425 Black Open-Hole Cap 100 73090<br />

13/425 Black Open-Hole Cap 1000 73092<br />

15/425 Black Open-Hole Cap 72 95261<br />

18/400 Black Open-Hole Cap 72 95281<br />

20/400 Black Open-Hole Cap 72 95301<br />

22/400 Black Open-Hole Cap 72 95331<br />

24/400 Black Open-Hole Cap 72 95321<br />

Septa for Open-Hole Caps<br />

4991<br />

Screw Thread Caps with Molded Septa<br />

• One-piece “Top Seal” closure saves time<br />

• 0.010" molded septum allows easy needle<br />

penetration<br />

• Polypropylene construction for solvent<br />

resistance<br />

Top Seal Closures with Septa—10mil<br />

Neck Finish Description Qty. Part No.<br />

Top Seal Closures with Molded Polypropylene Septa—10mil<br />

8/425 Clear Cap with Polypropylene Septum 100 98060<br />

8/425 Clear Cap with Polypropylene Septum 1000 98160<br />

10/425 Clear Cap with Polypropylene Septum 100 98405<br />

10/425 Clear Cap with Polypropylene Septum 1000 98407<br />

13/425 Clear Cap with Polypropylene Septum 100 98070<br />

13/425 Clear Cap with Polypropylene Septum 1000 98480<br />

Solid Top Screw Caps with Septa<br />

• Convenient for sample storage<br />

4989<br />

4990<br />

Septa for Open—Hole Caps<br />

Neck Finish Description Qty. Part No.<br />

Septa for Open—Hole Screw Thread Caps<br />

8/425 PTFE/Silicone Septum—5/55mil 100 73048<br />

8/425 PTFE/Silicone Septum—5/55mil 1000 73060<br />

8/425 PTFE/Silicone Septum—10/90mil 100 98499<br />

8/425 PTFE/Silicone Septum—10/90mil 1000 98497<br />

10/425 PTFE/Silicone Septum—5/55mil 100 98141<br />

10/425 PTFE/Silicone Septum—5/55mil 1000 98441<br />

13/425 PTFE/Silicone Septum—5/55mil 100 98846<br />

13/425 PTFE/Silicone Septum—5/55mil 1000 98848<br />

13/425 PTFE/Silicone Septum—10/90mil 100 98219<br />

13/425 PTFE/Silicone Septum—10/90mil 1000 95248<br />

15/425 PTFE/Silicone Septum—10/50mil 72 95262<br />

15/425 PTFE/Silicone Septum—10/90mil 100 98793<br />

18/400 PTFE/Silicone Septum—10/50mil 72 95282<br />

18/400 PTFE/Silicone Septum—10/90mil 72 95283<br />

20/400 PTFE/Silicone Septum—10/50mil 72 95302<br />

20/400 PTFE/Silicone Septum—10/90mil 72 95303<br />

22/400 PTFE/Silicone Septum—10/90mil 72 95333<br />

24/400 PTFE/Silicone Septum—10/50mil 72 95322<br />

24/400 PTFE/Silicone Septum—10/90mil 72 95323<br />

Open-Hole Screw Thread Caps with Septa<br />

Polypropylene Screw Thread Caps with Septa<br />

Neck Finish Description Qty. Part No.<br />

Open-Hole Screw Caps with PTFE/Silicone Septa— 60mil<br />

8/425 Black Cap with PTFE/Silicone Septum 100 98061<br />

10/425 Black Cap with PTFE/Silicone Septum 100 98144<br />

13/425 Black Cap with PTFE/Silicone Septum 100 98610<br />

Open-Hole Screw Caps with PTFE/Silicone/PTFE Septa— 40mil<br />

8/425 Black Cap with PTFE/Silicone/PTFE Septum 100 98701<br />

10/425 Black Cap with PTFE/Silicone/PTFE Septum 100 98705<br />

13/425 Black Cap with PTFE/Silicone/PTFE Septum 100 98735<br />

4683<br />

4761<br />

Solid Screw Thread Caps and Septa<br />

Neck Finish Description Qty. Part No.<br />

Solid Screw Thread Caps with Interseal PTFE/Silicone Bonded Septa<br />

13/425 White Cap with PTFE Septum 100 99031<br />

15/425 White Cap with PTFE Septum 100 99041<br />

18/400 White Cap with PTFE Septum 100 99050<br />

20/400 White Cap with PTFE Septum 100 99051<br />

22/400 White Cap with PTFE Septum 100 99052<br />

24/400 White Cap with PTFE Septum 100 99054<br />

Phenolic Solid Screw Thread Caps with PTFE/F217* Septa<br />

15/425 Green Cap with PTFE Septum 50 95269<br />

18/400 Green Cap with PTFE Septum 50 95289<br />

20/400 Green Cap with PTFE Septum 50 95309<br />

22/400 Green Cap with PTFE Septum 50 95339<br />

24/400 Green Cap with PTFE Septum 50 95329<br />

28/400 Green Cap with PTFE Septum 50 95395<br />

Polypropylene Solid Screw Thread Caps with PTFE Septa<br />

8/425 Black Cap with PTFE Septum 100 98063<br />

8/425 Black Cap with PTFE Septum 1000 98163<br />

10/425 Black Cap with PTFE Septum 100 98124<br />

10/425 Black Cap with PTFE Septum 1000 98424<br />

13/425 Black Cap with PTFE Septum 100 98430<br />

13/425 Black Cap with PTFE Septum 1000 98432<br />

Polypropylene Solid Threaded Cap with Polyethylene-Cone Septa<br />

13/425 Black Cap with Poly-Cone Septum 100 95247<br />

15/425 Black Cap with Poly-Cone Septum 100 95267<br />

18/400 Black Cap with Poly-Cone Septum 100 95287<br />

20/400 Black Cap with Poly-Cone Septum 100 95307<br />

22/400 Black Cap with Poly-Cone Septum 100 95337<br />

24/400 Black Cap with Poly-Cone Septum 100 95327<br />

28/400 Black Cap with Poly-Cone Septum 100 95393<br />

33/400 Black Cap with Poly-Cone Septum 100 95394<br />

Polypropylene Solid Screw Thread Caps, Unlined<br />

8/425 Black Cap 100 98105<br />

10/425 Black Cap 100 98162<br />

13/425 Black Cap 100 98614<br />

*F217—Polyethylene foam material.<br />

vials<br />

www.discoverysciences.com<br />

369


general chromatography<br />

Crimp Top Vials and Storage Bottles<br />

Crimp Top Containers Provide Positive<br />

Seal and Serve as Ideal Storage Vessels<br />

• Borosilicate glass containers<br />

• Supplied without seals<br />

Serum bottles are made of borosilicate glass<br />

that has a higher coefficient of expansion than<br />

autosampler vials. They have less resistance to<br />

sudden temperature changes.<br />

4750<br />

Crimp Top Vials and Bottles<br />

Glass<br />

Color<br />

Neck<br />

Finish<br />

Dia x Ht<br />

(mm) Qty. Part No. Qty. Part No.<br />

Volume<br />

Crimp Top Vials and Bottles<br />

0.3mL Clear 11mm 12x32 100 95240 1000 —<br />

0.3mL Amber 11mm 12x32 100 95268 1000 —<br />

0.5mL Clear 8mm 8x30 200 98819 1000 98823<br />

0.8mL Clear 8mm 7x40 200 98043 1000 98045<br />

0.8mL Amber 8mm 7x40 200 98896 1000 95170<br />

1mL Clear 8mm 8x40 125 98799 1000 98035<br />

1.5mL Clear 11mm 12x32 100 72009 1000 —<br />

2mL Clear 11mm 12x32 100 66002 1000 66003<br />

2mL Amber 11mm 12x32 100 95221 1000 95222<br />

2mL Clear 11mm 12x40 100 98273 1000 98570<br />

4mL Clear 13mm 15x45 100 98040 1000 98240<br />

4mL Amber 13mm 15x45 100 98097 1000 98297<br />

6mL Clear 20mm 22x38.5 100 99056 1000 99058<br />

9mL Clear 20mm 18x50 125 98098 1000 98548<br />

10mL Clear 20mm 22.5x46 100 6655 1000 66551<br />

12mL Clear 20mm 18x65 125 98104 1000 98877<br />

20mL Clear 20mm 22.5x75.5 100 6636 1000 66361<br />

27mL Clear 20mm 30x60 100 98093 1000 98546<br />

Crimp Top Serum Bottles<br />

4765<br />

Crimp Top Bottles and Stoppers<br />

Glass<br />

Color<br />

Neck<br />

Finish<br />

Dia x Ht<br />

(mm) Qty. Part No. Qty. Part No.<br />

Volume<br />

Crimp Top Vials and Bottles, Wheaton 400<br />

2mL Clear 13mm 15x40 288 66021 — —<br />

5mL Clear 20mm 23x47 288 66041 — —<br />

10mL Clear 20mm 25x54 288 66036 — —<br />

30mL Clear 20mm 37x63 288 66038 — —<br />

50mL Clear 20mm 43x73 288 66040 — —<br />

100mL Clear 20mm 52x95 144 66042 — —<br />

Stoppers for Serum Bottles<br />

11mm Natural Rubber Stoppers 100 6626 1000 66261<br />

13mm Natural Rubber Stoppers 72 95244 1000 95250<br />

13mm Butyl Rubber Stoppers 72 95245 1000 95252<br />

20mm Natural Rubber Stoppers 72 95304 1000 95255<br />

20mm Butyl Rubber Stoppers 72 95305 720 98811<br />

vials<br />

Stoppers<br />

more info<br />

For Aluminum Seals and Septa see page 371.<br />

more info<br />

For more information on Crimpers and Decappers,<br />

see page 383.<br />

4766<br />

Crimpers and Decappers<br />

Volume Description Qty. Part No.<br />

Adjustable Hand Crimpers for Crimp Top Vials<br />

8mm Hand Crimper* ea 666008<br />

11mm Hand Crimper ea 60041<br />

13mm Hand Crimper ea 60043<br />

20mm Hand Crimper ea 60045<br />

Hand Decappers for Crimp Top Vials<br />

8mm Hand Decapper ea 98709<br />

11mm Hand Decapper ea 98711<br />

13mm Hand Decapper ea 98713<br />

20mm Hand Decapper ea 98719<br />

Plier Decappers for Crimp Top Vials<br />

8mm Plier Decapper ea 6662<br />

11mm Plier Decapper ea 6660<br />

13mm Plier Decapper ea 6661<br />

20mm Plier Decapper ea 6663<br />

*Not adjustable.<br />

370 www.discoverysciences.com


general chromatography<br />

Aluminum Seals and Septa<br />

Aluminum Seals with Septa<br />

• One-piece design saves time by eliminating the process<br />

of inserting septa into the closures<br />

• For maximum sample protection, the seal should be<br />

replaced before storing the sample<br />

• Available in a wide assortment of colors<br />

Aluminum Seals, Unlined<br />

• Also a vailable in a wide assortment of colors.<br />

Call for additional colors.<br />

4999<br />

5003<br />

Aluminum Seals with Septa<br />

Description Size Qty. Part No.<br />

Seal with PTFE Septum—10mil<br />

Silver Seal 11mm 100 98013<br />

1000 98113<br />

13mm 100 98101<br />

1000 98103<br />

20mm* 100 99103<br />

1000 99105<br />

Seal with PTFE/Butyl Septum<br />

Silver Seal 8mm 100 94831<br />

1000 95172<br />

11mm 100 73070<br />

1000 73071<br />

13mm 100 98776<br />

1000 98206<br />

20mm 100 98801<br />

500 98552<br />

Red Seal 11mm 100 98051<br />

Blue Seal 11mm 100 98053<br />

Green Seal 11mm 100 98057<br />

Gold Seal 11mm 100 98059<br />

Seal with PTFE/Silicone —10/50mil<br />

Silver Seal 8mm 100 94832<br />

1000 94833<br />

11mm 100 98740<br />

1000 94867<br />

13mm 100 98283<br />

1000 98289<br />

20mm 100 95756<br />

1000 95758<br />

Seal with PTFE/Silicone/PTFE<br />

Silver Seal 8mm 100 94251<br />

1000 94253<br />

11mm 100 94855<br />

1000 94865<br />

13mm 100 98596<br />

1000 98598<br />

Seal with PP Septum—10mil<br />

Silver Seal 11mm 100 98011<br />

Seal with Pharma-Fix Septum<br />

Silver Seal 13mm 100 6687<br />

20mm 100 6689<br />

Seal with Black Fluoroelastomer Polymer Septum<br />

Silver Seal 8mm 100 94834<br />

1000 94835<br />

11mm 100 94852<br />

1000 94862<br />

*Not suitable for headspace seals.<br />

4754<br />

Aluminum Seals, Unlined<br />

Description Size Qty. Part No.<br />

Standard Seals<br />

Silver—Open Center 11mm 100 98746<br />

1000 66405<br />

Silver—Center Tear-Off 13mm 100 98778<br />

1000 66410<br />

Silver—Center Tear-Off 20mm 144 66440<br />

1440 98803<br />

Tear-Away<br />

Silver 13mm 100 98789<br />

1000 66416<br />

20mm 144 66501<br />

1440 98805<br />

Magnetic Tinplate<br />

Silver 20mm 100 98532<br />

Septa for Aluminum Seals<br />

• Refer to the septum compatibility<br />

guide on page 349 to choose<br />

the septum best suited for your<br />

application<br />

Septa for Aluminum Seals<br />

Description Size Qty. Part No.<br />

White PTFE Septum—10mil 11mm 100 98007<br />

13mm 100 98177<br />

PTFE/Silicone Septum— 60mil 11mm 100 98009<br />

1000 98019<br />

13mm 100 98791<br />

1000 95253<br />

PTFE/Silicone Septum—100mil 13mm 100 98793<br />

20mm 72 95313<br />

PTFE/Silicone/PTFE Septum— 40mil 11mm 100 98010<br />

1000 98020<br />

13mm 100 98180<br />

1000 98182<br />

PTFE/Butyl Rubber Septum— 40mil 11mm 100 98398<br />

1000 98400<br />

13mm 100 98173<br />

1000 98175<br />

Red Butyl Septum 20mm 100 98695<br />

Red Silicone Septum 20mm 72 98536<br />

1000 99108<br />

PTFE/Gray Butyl Septum 20mm 72 98540<br />

Aluminum/Silicone Septum— 60mil 20mm 72 98665<br />

more info<br />

For a complete listing of 20mm Aluminum Seals and Septa<br />

see page 365.<br />

4756<br />

vials<br />

www.discoverysciences.com<br />

371


general chromatography<br />

Shell Vials and Kits<br />

Shell Vials with Polyethylene Conical<br />

Starburst † Snap Plug Style Closures<br />

• Thicker glass walls for safer handling<br />

• Special safety plug eliminates sore fingers when pressing<br />

plugs into shell vials<br />

15x45mm<br />

Limited Volume Vials<br />

12x32mm<br />

Conical Snap Plug<br />

with pull tab and<br />

starburst<br />

4938<br />

8x40mm<br />

Conical Snap<br />

Plug with<br />

starburst<br />

Shell Vial Kits and Replacement Caps<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Description<br />

8x40mm (1mL) Kit Includes: Shell Vials, Clear Conical Snap Plugs<br />

Clear Vials, 200/pk 88631** 98834<br />

Amber Vials, 200/pk 88612** 98838<br />

Polypropylene Vials, 200/pk 88626** 98224<br />

Limited Volume Shell Vials (use Conical Plugs, not supplied with vials)<br />

700µL Polypropylene, 8x40mm 98990 98992<br />

8mm Replacement Polyethylene Conical Starburst Snap Plugs †<br />

Clear Plug 98994 98996<br />

Red Plug 99003 99013<br />

Blue Plug 99005 99015<br />

12x32mm (2mL) Kit Includes: Shell Vials, Clear Conical Snap Plugs<br />

Clear Vials 98840 98843<br />

Amber Vials 98845 98847<br />

Polypropylene Vials 98849 98851<br />

Polypropylene Vials for Dionex 91450 91455<br />

12mm Replacement Polyethylene Conical Starburst Snap Plugs †<br />

Clear Plug 98980 98989<br />

Red Plug 99033 99053<br />

Blue Plug 99035 99055<br />

15x45mm (4mL) Kit Includes: Shell Vials, Clear Conical Snap Plugs<br />

Clear Vials 98853 98857<br />

Amber Vials 98859 98863<br />

Polypropylene Vials 98867 98869<br />

Limited Volume Shell Vials (use Conical Plugs, not supplied with vials)<br />

15x45mm Polypropylene, 3mL 98972 98974<br />

15mm Replacement Polyethylene Conical Starburst Snap Plugs †<br />

Clear Plug 98976 98978<br />

Red Plug 99023 99043<br />

Blue Plug 99025 99045<br />

Green Plug 99027 99047<br />

Yellow Plug 99029 99049<br />

Safety Plug for Inserting Plugs into Any Size Shell Vial<br />

Multi-Plug Safety Sleeve, 5/pk 96431** —<br />

†<br />

With Starburst for easier needle penetration.<br />

**Correct quantity specified in description.<br />

4939<br />

vials<br />

8x40mm<br />

15x45mm<br />

TITESEAL ® Disposable Glass Shell Vials<br />

and Polyethylene Plug Style Closures<br />

• Maximum temperature use of 80°C for stopper<br />

TITESEAL ® Disposable Shell Vial Kits<br />

200/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Description<br />

Unassembled Disposable Vial Kits<br />

8x30mm (0.75mL), Clear Vials and Plugs 98824 73101<br />

8x43mm (1mL), Clear Vials and Plugs 98578 73146<br />

12x31mm (2mL), Clear Vials and Plugs 73112 98826<br />

15x45mm (4mL), Clear Vials and Plugs 98828 73131<br />

Replacement Plugs for TITESEAL ® Disposable Vials<br />

Plugs for 8mm Vials, 500/pk 73108** —<br />

Plugs for 12mm Vials, 500/pk 73120** —<br />

Plugs for 15mm Vials, 500/pk 73139** —<br />

**Correct quantity specified in description.<br />

4940<br />

15x45mm 12x31mm 8x43mm 8x30mm<br />

372 www.discoverysciences.com


general chromatography<br />

Polypropylene Vials for Ion Chromatography<br />

Polypropylene vials eliminate interferences associated with glass<br />

surfaces.<br />

tech tip<br />

Polypropylene containers<br />

Use of polypropylene containers is important to avoid the<br />

possibilities of interference from metallic ions that can be leached<br />

from glass containers under certain sampling conditions.<br />

related products<br />

Looking to further eliminate interferences in your samples<br />

for IC?<br />

See our IC SPE devices on pages 304 and 310.<br />

6521<br />

Polypropylene Vials and Caps<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Description<br />

12x32mm Standard Mouth Screw Thread Vials, 4mm i.d.<br />

600µL Polypropylene Vial, 8/425 Thread, 500/pk — 89073*<br />

100µL Polypropylene Vial with 8/425 Thread 12962 12963<br />

8/425 Black Cap with PTFE/Silicone Septum 98061 98066<br />

12x32mm Wide Mouth Screw Thread Vials, 6mm i.d.<br />

Kit—Includes Polypropylene Vial (98099),<br />

88538 —<br />

Red 10/425 Cap and 10mil PTFE Septum<br />

750µL Polypropylene Vial with 10/425 Thread 98099 98211<br />

500µL Polypropylene Vial with 10/425 Thread 98310 98314<br />

10/425 Black Cap with PTFE/Butyl Septum 97274 97216<br />

10/425 Black Cap with PTFE/Silicone Septum 98144 98152<br />

12x32mm Robotic LV Vials, 6mm i.d.<br />

1.5mL Clear Polypropylene Vial 99098 99140<br />

1.5mL Amber Polypropylene Vial 99109 99142<br />

100µL Polypropylene R.A.M. Vial 90273 90271<br />

9mm Blue R.A.M. Cap, PTFE/Silicone Septum 95360 95359<br />

12x32mm Crimp Style Vials, use 11mm Seal<br />

750µL Polypropylene Vial 98050 98215<br />

600µL Polypropylene Vial, 500/pk — 88363*<br />

500µL Polypropylene Vial 98842 98844<br />

300µL Polypropylene Vial 12990 12991<br />

100µL Polypropylene Vial 12960 12961<br />

11mm Aluminum Seal with PTFE/Butyl Septum 73070 73071<br />

11mm Aluminum Seal with PTFE/Silicone Septum 98740 94867<br />

11mm Poly Crimp Seal with PTFE/Butyl Septum 95232 95332<br />

11mm Poly Crimp Seal with PTFE/Silicone Septum 95234 95334<br />

8x30 and 8x40mm Shell Vials<br />

8x30mm Shell Vial, 900µL 99184 99192<br />

8x30mm Limited Volume Vial, 500µL 99178 99182<br />

8x40mm Polypropylene Shell Vial, 1mL 88625 98827<br />

8mm Polyethylene Starburst Snap Plug 88613 98865<br />

700µL LVI Polypropylene vial 98990 98992<br />

8mm Polyethylene Conical Plug 98994 98996<br />

15x45mm Vials<br />

2.5mL Polypropylene Vial, 13/425 Thread 98091 98491<br />

1.2mL Polypropylene Vial, 13/425 Thread 70149 70198<br />

13/425 Black Cap with PTFE/Silicone Septum 98610 98612<br />

3mL Polypropylene LVI Shell Vial 98972 98974<br />

13mm Clear Conical Plug 98976 98978<br />

2.5mL Crimp Style 98054 98254<br />

13mm Snap TOP Cap, PTFE/Silicone Septum 98044 98244<br />

*Actual quantity listed in description.<br />

For Polypropylene Limited Volume Inserts see:<br />

more info<br />

For 4mm i.d. Standard Mouth Vials, see page 361.<br />

more info<br />

For 6mm i.d. Wide Mouth Vials, see page 361.<br />

vials<br />

more info<br />

For 8x40mm Shell Vials, see page 354.<br />

4748<br />

more info<br />

For 15x45mm Vials, see page 362.<br />

Limited volume inserts provide greater access to small sample<br />

volumes.<br />

www.discoverysciences.com<br />

373


general chromatography<br />

Finneran Versa-Vials <br />

• Secure seal for sample integrity<br />

• Vase-like neck allows pick up with<br />

autosampler’s robotic arm<br />

• Selection of closures improves sample<br />

compatibility<br />

Easy use of pipet<br />

tips with 9.5mm i.d.<br />

opening.<br />

A new generation of 12x32mm shell vials to upgrade and automate your shell vial sampling.<br />

6460<br />

Soft press-in plugs<br />

eliminate breakage<br />

when capping.<br />

6461<br />

Versa-Vials and Plug Closures<br />

100/pk<br />

Part No.<br />

1000/pk<br />

Part No.<br />

Description<br />

Versa-Vials, 12x32mm, 1.8mm<br />

Clear Glass 99063 99163<br />

Amber Glass 99064 99164<br />

Clear Glass with Marking Spot 99066 99166<br />

Amber Glass with Marking Spot 99067 99167<br />

Limited Volume Inserts with Flanged Top<br />

250µL Glass, LVI 99095 99195<br />

250µL Polypropylene LVI 99089 99191<br />

350µL Polypropylene Flat Bottom 99183 99189<br />

Plug Closures<br />

PTFE/Silicone Plug with Slit* 99080 99082<br />

PTFE/Silicone Plug 99085 99087<br />

PTFE/Gray Chlorobutyl Plug 99090 99092<br />

Polyethylene Plug with Conical Starburst 99094 99096<br />

*Prevents bent needles.<br />

6461<br />

Tubes and Vials for Robotics<br />

vials<br />

Tubes and Vials for Robotics<br />

Description Qty. Part No. Qty. Part No.<br />

Culture Tubes, Borosilicate Glass<br />

10x75mm Tubes, 5mL 250 98829 1000 98590<br />

12x75mm Tubes, 6mL 250 98585 1000 98587<br />

13x100mm Tubes, 10mL 250 98589 1000 98591<br />

16x100mm Tubes, 15mL 250 98593 1000 98595<br />

20x150mm Tubes, 23mL 125 98597 500 98599<br />

25x150mm Tubes, 60mL 125 98601 500 98603<br />

Glass Autosampler Vials, Caps Sold Separately<br />

12x32mm Clear, Crimp Top, 11mm 100 66002 1000 66003<br />

12x32mm Amber, Crimp Top, 11mm 100 95221 1000 95222<br />

15x45mm Clear, 13/425 Screw Thread 100 98110 1000 98207<br />

15x45mm Amber, 13/425 Screw Thread 100 98120 1000 98484<br />

Scintillation Vials (Supplied with White Urea Caps with Cork Foil Liners)<br />

20mL Glass Scintillation Vials, 28x57 100 98613 500 98615<br />

20mL Polyethylene Scintillation Vials 100 98617 500 98619<br />

0522<br />

more info<br />

See also R.A.M. Vial page 355.<br />

374 www.discoverysciences.com


general chromatography<br />

Mini-Vials, Maxi-Vials, and Accessories<br />

Mini-Vials and Maxi-Vials<br />

• Heavy wall, clear<br />

borosilicate glass<br />

• Tapered cone for<br />

maximum recovery<br />

• Mini-vial starter kit<br />

contains 2 each of<br />

the 0.3, 1.0, 3.0 and<br />

5.0mL clear vials<br />

Mini-Vials and Accessories<br />

Description Qty. Part No.<br />

Clear Mini-Vials and Maxi-Vials (Supplied with Screw Caps)<br />

0.1mL Mini-Vials, 13/425 12 95001<br />

0.3mL Mini-Vials, 13/425 12 95003<br />

1.0mL Mini-Vials, 13/425 12 95010<br />

2.0mL Mini-Vials, 20/400 12 95020<br />

3.0mL Mini-Vials, 20/400 12 95030<br />

5.0mL Mini-Vials, 20/400 12 95050<br />

10.0mL Maxi-Vials, 20/400 12 95100<br />

Mini-Vial Starter Kit<br />

2 ea of 0.3, 1.0, 3.0 & 5.0mL Clear Vials ea 9511<br />

Caps<br />

13/425 Replacement Phenolic Caps 48 95090<br />

20/400 Replacement Phenolic Caps 48 95053<br />

Crimp Top Micro-Reaction Vials<br />

• Reusable, crimp-top mini-vial<br />

• Use 20mm aluminum seals<br />

• Cone-shaped interior for sample retrieval<br />

4757<br />

Mininert ® Valves<br />

• PTFE is only sample contact<br />

• Replace septum without exposing<br />

sample<br />

• Maximum pressure = 120psig<br />

• Use 20–26 gauge needles<br />

• Do not autoclave<br />

Mininert ® Valves and Accessories<br />

Description Qty. Part No.<br />

Mininert ® Valves<br />

13mm Mininert ® Valve for 13/425 Neck ea 9544<br />

12 95246<br />

15mm Mininert ® Valve for 15/425 Neck 12 95266<br />

18mm Mininert ® Valve for 18/400 Neck 12 95286<br />

20mm Mininert ® Valve for 20/400 Neck ea 9546<br />

12 95306<br />

24mm Mininert ® Valve for 24/400 Neck 12 95326<br />

Other Mininert ® Valves<br />

20mm Crimp Top Mininert ® Valve 12 66806<br />

Standard Taper Valve, 14/20 ea 621102<br />

Standard Taper Valve, 19/22 ea 621103<br />

1/4-28 Male to Mininert ® ea 631201<br />

1/4-28 Female to Mininert ® ea 631203<br />

1/4-28 Male to 1/4-28 Male ea 631205<br />

1/4-28 Female to 1/4-28 Female ea 631206<br />

1/8" Male NPT to Mininert ® ea 631202<br />

1/8" Female NPT to Mininert ® ea 631204<br />

Mininert ® Accessories<br />

Mininert ® Septum Inserter ea 644850<br />

Replacement Mininert ® Septa 12 9548<br />

50 644350<br />

4760<br />

Crimp Top Micro-Reaction Vials<br />

Description Qty. Part No.<br />

0.3mL Vials, 20mm Septa and Seals 5 9494<br />

1.0mL Vials, 20mm Septa and Seals 5 9495<br />

5.0mL Vials, 20mm Septa and Seals 5 9498<br />

20mm Standard Aluminum Seals 144 66440<br />

20mm Tear-Away Seals 144 66501<br />

Liners for 20mm Micro-Reaction Vials 12 9493<br />

Microflasks<br />

• Ideal for extraction of trihalomethanes<br />

(EPA Method 501.2)<br />

• Use screw-caps or 20mm<br />

Mininert ® valves<br />

• Do not autoclave<br />

4758<br />

4759<br />

Magnetic Stirring Bars<br />

• PTFE-coated, octagonals with<br />

a molded pivot ring<br />

Magnetic Stirring Bars for Vials<br />

Description Qty. Part No.<br />

Spin Vanes, for 0.3–1mL Mini-Vials 6 903061<br />

Spin Vanes, for 2–10mL Mini-Vials 6 903063<br />

Stirring Bars, 1.5x8mm 6 9670<br />

Stirring Bars, 3x12.7mm 6 9672<br />

Stirring Bars, 8x16mm 6 9674<br />

Stirring Bars, 8x25.4mm 6 9676<br />

Stirring Bars, 9.5x38mm 6 9678<br />

Stirring Bars, 9.5x51mm 6 9680<br />

PTFE Coated Stirring Retriever*, 9.5x300mm ea 9682<br />

*Polyethylene.<br />

4960<br />

vials<br />

Microflasks<br />

Description Qty. Part No.<br />

10mL Microflask 12 9551<br />

25mL Microflask 12 9553<br />

Open-Hole Screw Caps, 20/400 72 95301<br />

PTFE/Silicone Septa for Screw Caps 72 95302<br />

PTFE/Silicone Septa, 10/90 for Caps 72 95303<br />

www.discoverysciences.com<br />

375


general chromatography<br />

EPA Sample Containers<br />

Variety of storage bottle sizes and styles in glass or<br />

polyethylene. Available unwashed or cleaned to meet<br />

requirements for VOA analyses<br />

related products<br />

Working on an EPA method?<br />

Refer to pages 232–234 for our<br />

Guide to Capillary Columns for<br />

Environmental Analysis.<br />

Septa Bottles<br />

4944<br />

Wide Mouth Glass Jars<br />

5318<br />

Polyethylene (HDPE) Cylinders<br />

4945<br />

EPA Sample Containers<br />

Volume, Description,<br />

Neck Finish (Cap Size)<br />

Dimensions<br />

Ht x Dia Qty.<br />

Unwashed<br />

Part No.<br />

Washed<br />

Part No.<br />

Septa Bottles — Supplied with Open Top Poly Caps with<br />

PTFE/Silicone Septa<br />

8oz (250mL), Amber Septa 5-11/16" x 2-3/8" 12 89159 89158<br />

Bottle, 24/414<br />

4oz (125mL), Clear Tall 4" x 1-7/8" 24 89099 89079<br />

Septa Jar, 48/400<br />

Wide Mouth Glass Jars — Supplied with Poly Caps with PTFE Septa<br />

4oz (125mL), Clear Tall 4" x 1-7/8" 24 89198 89169<br />

Glass Jar, 48/400<br />

4oz (125mL), Clear Short 2-1/8" x 2-3/8" 24 89309 89308<br />

Glass Jar, 58/400<br />

4oz (125mL), Amber Glass 3-13/16" x 2" 24 89332 89320<br />

Jar, 38/400<br />

8oz (250mL), Clear Short 3-3/8" x 2-7/8" 24 89168 89167<br />

Glass Jar, 70/400<br />

8oz (250mL), Amber Glass 4-3/4" x 2-1/2" 24 89359 89351<br />

Jar, 45/400<br />

16oz (500mL), Clear Short 3-3/4" x 3-1/2" 12 89356 89352<br />

Glass Jar, 89/400<br />

16oz (500mL), Amber 5-7/8" x 3-1/8" 12 89360 89353<br />

Glass Jar, 53/400<br />

32oz (1.0L), Clear Tall 6-1/2" x 3-5/8" 12 89367 89354<br />

Glass Jar, 89/400<br />

32oz (.95L), Amber Glass 6-1/2" x 3-5/8" 12 89368 89355<br />

Jar, 53/400<br />

High Density Polyethylene (HDPE) Cylinders —With Poly Caps and<br />

Polyfoam Septa<br />

8oz (250mL), HDPE Round 6-1/8" x 2" 24 89372 89369<br />

Cylinder, 24/410<br />

16oz (500mL), HDPE 7-3/8" x 2-1/2" 24 89373 89370<br />

Round Cylinder, 28/410<br />

32oz (1.0L), HDPE Round<br />

Cylinder, 28/410<br />

9-3/8" x 3" 12 89374 89371<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

6534<br />

vials<br />

376 www.discoverysciences.com


general chromatography<br />

EPA Vials for Volatile Organic Analyses<br />

• Available washed* or unwashed in 20, 40, and 60mL vial<br />

sizes and in 12x32 and 15x45mm autosampler vial sizes<br />

• Washed* EPA vials are supplied with a certificate of<br />

analysis—equivalent to I-CHEM Series 3<br />

• Washed vials are recommended for the analysis of<br />

volatile organics<br />

• All vials are borosilicate glass<br />

• Three septum choices for maximum versatility—0.125"<br />

for EPA/VOA Samples, 0.125" TOP Hat Septum Locks<br />

Securely Into Cap, 0.06" for autosampler use (purchase<br />

separately)<br />

• All are supplied as kits with vial and cap specified<br />

*Washed to Protocol B specifications.<br />

Cleaning Protocol B<br />

1. Wash bottles, septa, and caps in laboratory grade, biodegradable,<br />

non-phosphate detergent.<br />

2. Rinse three times with tap water.<br />

3. Rinse three times with ASTM Type one deionized water.<br />

4. Oven dry.<br />

5. Assemble in organic-free environment.<br />

tech tip<br />

Advantages of TOP Hat Closure<br />

• Molded TOP* Hat PTFE/Silicone septum locks into its unique<br />

cap opening<br />

• Prevents septa falling out of caps<br />

• Available for washed or unwashed vials in all sizes<br />

Cross-Section Cap and Septum<br />

125 mil Septum<br />

*Time Oriented Products.<br />

TOP Hat Septum locks securely<br />

into the black cap.<br />

6296<br />

EPA/VOA Vial Kits<br />

Description<br />

Qty.<br />

Unwashed<br />

Part No. Qty.<br />

Washed<br />

Part No.<br />

20mL Vials<br />

Clear Vials, White Caps,<br />

72 89515 72 89517<br />

PTFE/Silicone Septa<br />

Amber Vials, White Caps,<br />

72 89516 72 89518<br />

PTFE/Silicone Septa<br />

Clear Vials, Solid White Cap, PTFE — — 72 89325<br />

Septum<br />

Clear Vials, Black Caps, 0.125" TOP 72 98641 72 98643<br />

Hat PTFE/Silicone Septa*<br />

40mL Vials<br />

Clear Vials, White Caps,<br />

72 89525 72 89527<br />

PTFE/Silicone Septa<br />

Amber Vials, White Caps,<br />

72 89526 72 89528<br />

PTFE/Silicone Septa<br />

Clear Vials, Solid White Cap PTFE — — 72 89326<br />

Septum<br />

Amber Vials, Solid White Cap,<br />

— — 72 89199<br />

PTFE Septum<br />

Clear Vials, Black Caps, TOP Hat 72 98649 72 98651<br />

PTFE/Silicone Septa*<br />

60mL Vials<br />

Clear Vials, White Caps,<br />

72 89535 72 89537<br />

PTFE/Silicone Septa<br />

Clear Vials, Solid White Caps with — — 24 89327<br />

PTFE Septa<br />

Clear Vials, Black Caps, TOP Hat 24 98657 24 98659<br />

PTFE/Silicone Septa*, 24/pk<br />

12x32mm (2mL) Vials with Cap and Septum<br />

Clear Screw thread (8/425) Vial, Cap 100 98625 100 98627<br />

with PTFE/Silicone/TOP Hat Septum<br />

15x45mm (2mL) Vials with Cap and Septum<br />

Clear Screw thread (13/425) Vial, Cap 100 98633 100 98635<br />

with PTFE/Silicone/TOP Hat Septum<br />

24/414 Replacement Caps with Septa for EPA Vials, Unwashed<br />

White Caps with 0.060"<br />

100 89519 — —<br />

PTFE/Silicone Septa<br />

White Caps with 0.060"<br />

1000 89520 — —<br />

PTFE/Silicone Septa<br />

Black Caps, TOP Hat<br />

100 98085 — —<br />

PTFE/Silicone Septa*<br />

Black Caps, TOP Hat<br />

1000 98079 — —<br />

PTFE/Silicone Septa*<br />

White Cap Only 100 89226 — —<br />

0.125" Septum for EPA Vials 100 89277 — —<br />

*Patented TOP Hat Closure with 125mil septum meets EPA Requirements.<br />

vials<br />

www.discoverysciences.com<br />

377


general chromatography<br />

I-CHEM Vials<br />

• 20, 40, and 60mL I-CHEM vials<br />

for EPA volatile organic analyses<br />

• All vials are borosilicate glass<br />

• Choice of closure/liner for<br />

maximum versatility—0.06 for<br />

autosampler use, 0.125 for<br />

EPA/VOA samples<br />

I-CHEM Sample<br />

Containers<br />

Septa Bottles and Jars<br />

• For analysis of volatile organics<br />

Wide Mouth Glass Jars<br />

• For semi-volatile, PCBs/pesticide, metals,<br />

and cyanide analysis<br />

4944<br />

4943<br />

I-Chem EPA/VOA Vials—Series 2**<br />

Description Qty. Part No.<br />

Processed* I-CHEM Vials, Assembled with Caps and Septa<br />

20mL Vials, Processed<br />

Clear Vials, 24/414 Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 98702<br />

Clear Vials, 24/414 Solid Caps, PTFE Septum 72 98704<br />

40mL Vials, Processed<br />

Clear Vials, 24/414 Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 98706<br />

Amber Vials, 24/414 Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 98708<br />

Clear Vials, 24/414 Open-Hole Caps, 0.060" PTFE/Silicone Septum 72 98710<br />

Amber Vials, 24/414 Open-Hole Caps, 0.060" PTFE/Silicone Septum 72 98712<br />

Clear Vials, 24/414 Solid Caps, PTFE Septum 72 98714<br />

Amber Vials, 24/414 Solid Caps, PTFE Septum 72 98716<br />

60mL Vials, Processed<br />

Clear Vials, 24/414 Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 97022<br />

Amber Vials, 24/414 Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 97024<br />

Unwashed I-CHEM Vials, Assembled with Caps and Septa<br />

20mL Vials, Unwashed<br />

Clear Vials, Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 98682<br />

Clear Vials, 24/414 Solid Caps, PTFE Septum 72 98684<br />

40mL Vials, Unwashed<br />

Clear Vials, Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 98686<br />

Amber Vials, Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 98688<br />

Clear Vials, Open-Hole Caps, 0.060" PTFE/Silicone Septum 72 98690<br />

Amber Vials, Open-Hole Caps, 0.060" PTFE/Silicone Septum 72 98692<br />

Clear Vials, 24/414 Solid Caps, PTFE Septum 72 98694<br />

Amber Vials, 24/414 Solid Caps, PTFE Septum 72 98696<br />

60mL Vials, Unwashed<br />

Clear Vials, Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 97012<br />

Amber Vials, Open-Hole Caps, 0.125" PTFE/Silicone Septum 72 97014<br />

*Processed vials are recommended for use in analysis of volatile organics.<br />

**Certificate of analysis is available by lot number. Request after purchase.<br />

Replacement Caps and Septa for I-CHEM Vials<br />

Description Qty. Part No.<br />

Caps Only, 24/414, Open Top without Septum 24 92414<br />

Septa Only, 0.125" PTFE/Silicone 24 92416<br />

vials<br />

Polyethylene (HDPE) Round Cylinders<br />

• For metals and cyanide analysis<br />

5318<br />

4945<br />

I-CHEM Sample Containers<br />

Neck Finish<br />

(Cap Size)<br />

Dimensions<br />

Ht x Dia Qty. Part No.<br />

Volume<br />

Description<br />

Septa Bottles — Supplied with Open Top Poly Caps with PTFE/Silicone Septa<br />

8oz (250mL) Amber Septa Bottle 24/414 5-11/16" x 2-3/8" 12 98720<br />

4oz (125mL) Clear Tall Septa Jar 48/400 4" x 1-7/8" 12 98722<br />

Wide Mouth Glass Jars — Supplied with Poly Caps with PTFE Septa<br />

4oz (125mL) Clear Tall Glass Jar 48/400 4" x 1-7/8" 12 98718<br />

4oz (125mL) Clear Short Glass Jar 58/400 2-1/8" x 2-3/8" 24 98732<br />

4oz (125mL) Amber Glass Jar 38/400 3-13/16" x 2" 12 98734<br />

8oz (250mL) Clear Tall Glass Jar 58/400 4-13/16" x 2-1/4" 12 98698<br />

8oz (250mL) Clear Short Glass Jar 70/400 3-3/8" x 2-7/8" 12 98576<br />

8oz (250mL) Amber Glass Jar 45/400 4-3/4" x 2-1/2" 12 98700<br />

16oz (500mL) Clear Short Glass Jar 89/400 3-3/4" x 3-1/2" 12 98736<br />

16oz (500mL) Amber Glass Jar 53/400 5-7/8" x 3-1/8" 12 98738<br />

32oz (1.0L) Clear Tall Glass Jar 89/400 6-1/2" x 3-5/8" 12 98399<br />

32oz (.95L) Amber Glass Jar 53/400 6-1/2" x 3-5/8" 12 98730<br />

High Density Polyethylene (HDPE) Cylinders —with Poly Caps and Polyfoam Septa<br />

8oz (250mL) HDPE Round Cylinder 24/410 6-1/8" x 2" 24 98724<br />

16oz (500mL) HDPE Round Cylinder 28/410 7-3/8" x 2-1/2" 24 98726<br />

32oz (1.0L) HDPE Round Cylinder 28/410 9-3/8" x 3" 12 98728<br />

378 www.discoverysciences.com


general chromatography<br />

96-Well Products<br />

Glass Inserts for 96-Well Plates<br />

for Waters ® Alliance ® HT System* Ritter Style Plate<br />

• Push-point tip design allows sample access to 10µL<br />

• Snug fit allows use with shakers and vortexers<br />

• Use molded covers or 8mm snap plugs for inserts<br />

• Ideal solution for reactive chemistry applications<br />

96-Deep Well<br />

Microplates and<br />

Cover Mats<br />

• Standard 8x12 format<br />

• Borosilicate glass plates<br />

• Polypropylene square or round wells<br />

3488 4348<br />

Microplates and Accessories<br />

Description, Well Capacity, Well Volume Qty. Part No.<br />

All-Glass 96-Well, Class A Borosilicate Plates<br />

Glass, Flat Bottom, 500µL 1 91504<br />

96-Well Square Deep Microplates and Caps<br />

Polypropylene, Square Deep Well, 2mL 100 80910<br />

Glass inserts eliminate chemical resistance problems associated with<br />

polypropylene 96-well plates for chromatography analysis.<br />

Components for 96-Well Ritter Style System<br />

Description Qty. Part No.<br />

Borosilicate Glass Inserts for Square Well Plates<br />

0.7mL Glass Tapered Insert 100 91501<br />

1.0mL Glass Tapered Insert, Flat Tip 100 91508<br />

Covers for 1mL Inserts in Plate, Molded Round Well<br />

PTFE/Blue Silicone 5 91496<br />

Convenience Kits: Plate with Inserts Inserted<br />

Plate with 0.7mL Insert 1 91497<br />

Plate with 1.0mL Insert 1 91505<br />

Plate with 1mL Flat Tip Insert 1 91509<br />

*Ritter style plate designed for use in Waters ® Alliance ® HT (2790/2795) system. Inserts<br />

also work in equivalent deep well 2mL plates.<br />

96-Well µLPLATES and Inserts<br />

• In Polypropylene or PTFE<br />

• Piercible non-coring covers<br />

• Choice of shallow, medium, or deep wells<br />

• Chimney well design prevents sample crossover<br />

Components for µLPlate System<br />

Description Qty. Part No.<br />

Microliter 96-Well Plates<br />

Deep-Well Plates, Polypropylene<br />

2.0mL, Square Well, V-Bottom Plates 1 70098<br />

Shallow and Medium-Well Plates, Polypropylene<br />

500µL, Medium, Round Well, Round Bottom Plates 1 70089<br />

Shallow-Well Plates, PTFE<br />

450µL, Round Well, Round Bottom Plates 1 70208<br />

Borosilicate Glass Inserts for µLPLATES<br />

For Medium Well Plates*<br />

350µL Inserts for 12x32mm Vials 100 70048<br />

350µL Silanized Inserts for 12x32mm Vials 100 70063<br />

*Use 350µL insert to transfer directly from 96-well plate to 12x32mm robotic<br />

autosampler vials.<br />

6778<br />

Bio-Tech Sealing Systems<br />

Molded Liners for Round or Square 96-Well Plates<br />

• Superior resealability, resists coring<br />

and tearing<br />

• Tight seal prevents cross<br />

contamination and<br />

sample evaporation<br />

• Autoclavable and excellent<br />

chemical compatibility<br />

• Now available in clear pre-slit<br />

design<br />

Molded Liners for 96-Well Plates<br />

Description Qty. Part No.<br />

Gray PTFE-Lined Silicone<br />

Round well 5 91458<br />

Square well 5 91464<br />

Clear PTFE-Lined Silicone<br />

Round well 5 8619141<br />

Round well, Pre-slit 5 8619145<br />

Square well 5 8619142<br />

Square well, Pre-slit 5 8619146<br />

Sealing Films for Round or<br />

Square Well Plates<br />

• Superior quality films with uniform,<br />

consistently applied adhesive<br />

• Adheres to polypropylene, polystyrene,<br />

or polycarbonate plates<br />

• Choices offer temperature and<br />

chemical resistance<br />

• Fits all 96-well, 384-well, and<br />

1536-well plates<br />

SealPlate<br />

Blue PTFE<br />

new<br />

Sealing Films for 96-Well Plates<br />

Description Qty Part No.<br />

Blue PTFE Film, Adhesive-Free Over 96-Well Area<br />

5mil Thickness 100 91490<br />

SealPlate for ELISA, EIA, and Similar Assays<br />

2mil Polyester Film, Non-pierce 100 91487<br />

Aluminum Foil Film for Light Sensitive Samples<br />

Pierceable, for Robotics 100 91488<br />

7441<br />

6681<br />

6683<br />

vials<br />

www.discoverysciences.com<br />

379


general chromatography<br />

Racks and Storage Containers<br />

Polypropylene Vial Storage Racks<br />

• Choice of sizes to fit<br />

8 to 28mm o.d. vials<br />

• Autoclavable<br />

• Stackable<br />

4951<br />

Polypropylene Vial Storage Racks<br />

Fits Vial<br />

Diameter<br />

Holds<br />

(#Vials) Description Qty. Part No.<br />

8mm 96 185mm x 127mm x 33mm ea 94838<br />

8mm 96 185mm x 127mm x 33mm 5 94839<br />

12mm 50 194mm x 100mm x 23mm ea 94874<br />

12mm 50 194mm x 100mm x 23mm 5 94875<br />

15mm 48 270mm x 97mm x 30mm ea 94877<br />

15mm 48 270mm x 97mm x 30mm 5 94878<br />

15mm 90 327mm x 172mm x 30mm ea 94879<br />

15mm 90 327mm x 172mm x 30mm 5 94880<br />

28mm 50 325mm x 171mm x 30mm/EPA ea 94881<br />

28mm 50 325mm x 171mm x 30mm/EPA 5 94882<br />

Polypropylene Rack with Handle<br />

• Stackable—empty or full<br />

• Autoclavable<br />

3432<br />

Ampul-store<br />

• Eliminates need to relabel or transfer<br />

open 2mL ampule contents<br />

• Minimizes sample odors in the lab<br />

To use: Break off the ampule top. Place<br />

the ampule in the Ampul-store and attach<br />

cap. Inject through the open top screw<br />

cap/stopper to remove sample.<br />

ampul-store<br />

Description Qty. Part No.<br />

2mL Silanized Amber Ampules 36 72690<br />

Ampul-store for 2mL Ampules 5 98932<br />

The Ampule Cracker<br />

Slip the Ampule Cracker over the top at the<br />

prescored position, snap it, and discard<br />

both the ampule top and the safety collar to<br />

prevent contamination.<br />

Ampule Cracker<br />

Description Qty. Part No.<br />

Ampule Cracker for 1–4mL Ampules 100 01111<br />

4957<br />

4958<br />

Polypropylene with Handle<br />

Fits Vial<br />

Diameter<br />

Holds<br />

(#Vials) Description Qty. Part No.<br />

10–33 72 9-3/8" x 4-3/8" x 3-1/2" ea 2035<br />

13–16 40 10" x 4-3/8" x 3-1/2" ea 2037<br />

16–20 40 10" x 4-3/8" x 3-1/2" ea 2039<br />

21–25 40 10-5/8" x 5" x 5" ea 2041<br />

26–30 24 11-3/4" x 5" x 3-3/4" ea 2043<br />

Stretch-it—PTFE Sealing Tape<br />

• Provides a chemically resistant<br />

cover for reactions in progress<br />

• Eliminates deteriorated foil and<br />

paraffin film covers<br />

• 108ft per roll<br />

3426<br />

Metal Storage Cabinet<br />

• 9-drawer metal cabinet provides<br />

clean organized vial storage<br />

• Dimensions: 11" H x 17" W x 11" D<br />

(28cm H x 43cm W x 28cm D)<br />

Stretch-it-PTFE Sealing Tape<br />

Description Qty. Part No.<br />

1/2" Wide ea 3241<br />

3/4" Wide ea 3243<br />

1" Wide ea 3245<br />

3" Wide ea 3247<br />

4" Wide ea 3248<br />

5" Wide ea 3249<br />

4952<br />

vials<br />

metal storage cabinet<br />

Description Qty. Part No.<br />

9-Drawer Metal Storage Cabinet ea 98934<br />

Plastic Storage Boxes<br />

• Convenient accessible storage of<br />

small parts<br />

• Available with 1, 9, or 18<br />

compartments<br />

5772<br />

Plastic Storage Boxes<br />

Description Qty. Part No.<br />

1 Compartment, 9" x 5" x 2" ea 98928<br />

9 Compartment, 8 of (1-3/8" x 1-5/8")<br />

ea 6264<br />

1 of (1-1/8" x 3-1/4")<br />

18 Compartment, 12 of (2" x 2") 6 of (2" x 4-3/16") ea 6266<br />

380 www.discoverysciences.com


general chromatography<br />

Racks and Storage Containers<br />

The Polypropylene Snap Rack<br />

• Stores vials and caps together<br />

• Stackable<br />

Polypropylene Gridded Boxes in Neon Colors<br />

• Hold either 50 or 100<br />

12x32mm vials<br />

• Available in blue, green,<br />

orange, pink, yellow, and<br />

clear for colorful storage<br />

and identification<br />

Polypropylene Snap Rack<br />

Description Qty. Part No.<br />

8mm Snap Rack Tray, Holds 96 Vials ea 95076<br />

12mm Snap Rack Tray, Holds 50 Vials ea 95086<br />

VialTainer Storage Box<br />

• Clear polystyrene box<br />

• Designed for use with<br />

autosampler vials<br />

4955<br />

Specifications<br />

Raised Edges Provide Non-Slip, Stackable Storage with Writing Panel on<br />

Lid Front for i.d.<br />

Alpha-Numeric Code on Grids for Easy Sample i.d.<br />

Hinged Lid with Secure Snap Clasp<br />

Rated to -90°C, Ideal for Freezer or Room Storage<br />

Dimensions: 100 Grid—2.1" H x 6.0" W x 5.5" L<br />

(53mm H x 152mm W x 140mm L)<br />

50 Grid—2.1" H x 3" W x 5.5" L<br />

(53mm H x 76mm W x 140mm L)<br />

3697<br />

VialTainer Storage Box<br />

Fits Vial<br />

Diameter<br />

Freezer Racks<br />

Holds<br />

(#Vials) Description Qty. Part No.<br />

12mm 72 Small, 189x94x62mm 4 2049<br />

15mm 40 Large, 189x94x62mm 4 2051<br />

• Hold 80 microcentrifuge tubes<br />

• Autoclavable<br />

• Polypropylene racks<br />

Freezer Racks<br />

Description Qty. Part No.<br />

Racks, 1 of ea: Red, Blue, Orange, Green, Yellow 5 7363<br />

3428<br />

3421<br />

Neon Storage Boxes<br />

Fits Vial<br />

Diameter<br />

Holds<br />

(#Vials) Description Qty. Part No.<br />

To Hold 100 Vials<br />

12mm 100 Clear 5 95129<br />

12mm 100 Blue Neon 5 95131<br />

12mm 100 Green Neon 5 95132<br />

12mm 100 Orange Neon 5 95133<br />

12mm 100 Pink Neon 5 95134<br />

12mm 100 Yellow Neon 5 95135<br />

12mm 100 Assorted, 1 of ea/5 Colors 5 95005<br />

To Hold 50 Vials<br />

12mm 50 Clear 5 95029<br />

12mm 50 Blue Neon 5 95106<br />

12mm 50 Green Neon 5 95027<br />

12mm 50 Orange Neon 5 95028<br />

12mm 50 Pink Neon 5 95089<br />

12mm 50 Yellow Neon 5 95108<br />

12mm 50 Assorted, 1 of ea/5 Colors 5 95008<br />

Floating Racks<br />

• Polyfoam racks hold multiple<br />

tube sizes<br />

• Ideal for water baths<br />

Multi-Use Vial Rack System<br />

• Increased spacing around vials for easy sample access<br />

• PETG trays snap easily into<br />

the polypropylene frame<br />

• Holder and trays sold<br />

separately<br />

vials<br />

Floating Racks<br />

Description Qty. Part No.<br />

Small, Hold 0.5 or 0.25mL Tubes 3 7320<br />

Medium, Hold 0.5 and 1.5mL Tubes 3 7322<br />

Large, Hold 15 and 50mL Tubes 3 7324<br />

Assorted, 1 each of Small, Medium, and Large 3 7318<br />

3413<br />

Multi-Use Vial Rack System<br />

Fits Vial<br />

Diameter<br />

Holds<br />

(#Vials) Description Qty. Part No.<br />

— — Universal Tray Holders 5 98600<br />

5mm 25 Insert Trays, 98x105mm 5 98671<br />

7mm 25 Insert Trays, 98x105mm 5 98673<br />

8mm 25 Insert Trays, 98x105mm 5 98675<br />

12mm 25 Insert Trays, 98x105mm 5 98677<br />

15mm 25 Insert Trays, 98x105mm 5 98679<br />

4954<br />

www.discoverysciences.com<br />

381


general chromatography<br />

Sampling Handling Accessories<br />

Block Heaters<br />

• Use to control reaction<br />

temperatures<br />

• Use solid block as hot plate or<br />

drill to fit vials<br />

The block heater has separate high<br />

and low thermostats and has an<br />

on-off switch and pilot light. The low setting is for ambient to<br />

60°C, while the high setting covers the 50 to 130°C range.<br />

The heater measures 3" H x 5" W x 8" L (7.6cm H x<br />

12.7cm W x 20.3cm L).<br />

All of the blocks listed are 2" H x 2-15/16" W x 3-3/4" L<br />

(5.1cm H x 7.5cm W x 9.5cm L) and are interchangeable.<br />

Wells are 1.75" (44cm) deep with rounded bottoms.<br />

Block Heaters<br />

Description Qty. Part No.<br />

Temp-Block*, 110V ea 9707<br />

Temp-Block*, 220V ea 97071<br />

Heating Block, 20x13.5mm Holes ea 9708<br />

Heating Block, 12x17.5mm Holes ea 9709<br />

Heating Block, 8x20.5mm Holes ea 9710<br />

Heating Block, 6x25.4mm Holes ea 9711<br />

Heating Block, Solid ea 9711S<br />

Thermometer, -20 to 150°C ea 9711T<br />

*Order Temp-block and Heating Blocks separately.<br />

related products<br />

Looking for gas sampling<br />

bags and other gas<br />

sampling accessories?<br />

See pages 276–279.<br />

4961<br />

Vacuum Bottles with Septum Ports<br />

• Prepare gaseous calibration blends<br />

• Easy sampling with a syringe<br />

• Measure volatiles in packaging materials<br />

• Prepare coated packings<br />

• Wide-mouth accessibility<br />

Vacuum Bottles with Septum Ports<br />

Description Qty. Part No.<br />

170cc, 2" Mouth, 2" Diameter, 5.5" Height ea 8089<br />

390cc, 2" Mouth, 2" Diameter, 6.5" Height ea 8090<br />

770cc, 3" Mouth, 3" Diameter, 10" Height ea 8091<br />

1350cc, 3" Mouth, 3" Diameter, 12" Height ea 8092<br />

2300cc, 3" Mouth, 3" Diameter, 9" Height ea 8093<br />

Replacement Parts for Vacuum Bottles<br />

Septa, Red Silicone, 6mm o.d. x 8mm 12/pk 7000<br />

Septa-Out (Removal Tool) ea 6412<br />

Replacement O-rings, 2" ea 8087<br />

Replacement O-rings, 3" ea 8088<br />

Diazomethane Generators<br />

Diazomethane is used to methylate acidic<br />

compounds for analysis by gas chromatography.<br />

It offers the advantages of clean and quantitative<br />

reactions but it is highly toxic and explosive.<br />

Instructions for use are included with each unit.<br />

Note: Always use appropriate safety precautions<br />

when handling and preparing diazomethane and<br />

its solutions.<br />

4965<br />

6647<br />

4664<br />

Diazomethane Generators<br />

Description Qty. Part No.<br />

Diazomethane Generators (Milli-Mole Size) ea 9559<br />

Replacement PTFE/Silicone Septa 72 95242<br />

4963<br />

technical assistance<br />

Contact Tech Support: Phone: 1.800.255.8324 (North America)<br />

Email: contact.alltech@grace.com<br />

Online: www.discoverysciences.com<br />

vials<br />

382 www.discoverysciences.com


general chromatography<br />

Crimpers and Decappers<br />

Adjustable Hand Crimper<br />

• Adjustable block corrects for differences in septum<br />

thicknesses<br />

The Adjustable Crimper has an adjustable pressure block<br />

in the crimper head that allows crimping of liners with a<br />

thickness range of 0.25 to 3.0mm. The unit looks like the<br />

standard hand crimper but it is supplied with an allen wrench<br />

and special instructions for making adjustments.<br />

Adjustable Crimper Instructions<br />

Adjustment Method:<br />

1. Hold crimper with jaws up,<br />

notice hex socket screw.<br />

2. Insert hex wrench into<br />

screw socket.<br />

3. For looser septa, turn screw<br />

clockwise 1/8" turn. For tighter<br />

septa, turn screw counter<br />

clockwise 1/8" turn.<br />

4953<br />

The crimper has an adjustment feature which will allow it to be<br />

used with a variety of septa, discs, stoppers or lined caps. The<br />

user may adjust the stroke or movement for each application<br />

as needed.<br />

4948<br />

Hand Crimper<br />

• Permits minor handle pressure adjustments<br />

• Works best for seals with 40–50mil liners<br />

tech tip<br />

What’s special about the adjustable hand crimpers?<br />

The new design has an adjustable pressure block that corrects<br />

for differences in septum thickness and provides a tighter seal.<br />

Crimping is accomplished by placing the crimper head over the<br />

aluminum seal and squeezing the handle.<br />

4947<br />

Hand Decapper<br />

• Removes crimped seals from vials<br />

4329<br />

Plier Decapper<br />

• Inexpensive tool to remove sealed caps<br />

3309<br />

4949<br />

Crimpers and Decappers<br />

Volume Description Qty Part No.<br />

Adjustable Hand Crimpers for Crimp Top Vials<br />

11mm Hand Crimper ea 60041<br />

13mm Hand Crimper ea 60043<br />

20mm Hand Crimper ea 60045<br />

Hand Crimpers for Crimp Top Vials<br />

8mm Hand Crimper ea 666008<br />

11mm Hand Crimper ea 666011<br />

13mm Hand Crimper ea 666013<br />

20mm Hand Crimper ea 666020<br />

Hand Decappers for Crimp Top Vials<br />

8mm Hand Decapper ea 98709<br />

11mm Hand Decapper ea 98711<br />

13mm Hand Decapper ea 98713<br />

20mm Hand Decapper ea 98719<br />

Plier Decappers for Crimp Top Vials<br />

8mm Plier Decapper ea 6662<br />

11mm Plier Decapper ea 6660<br />

13mm Plier Decapper ea 6661<br />

20mm Plier Decapper ea 6663<br />

vials<br />

www.discoverysciences.com<br />

383


general chromatography<br />

Color-Coded PEEK Tubing<br />

• Chemically inert and biocompatible<br />

• High strength polymer replaces stainless steel<br />

• Easy to cut with razor blade or tubing cutters<br />

PEEK tubing is the ideal metal-free tubing. Its mechanical<br />

strength, chemical resistance, and biocompatibility make<br />

it appropriate for a wide variety of high pressure LC<br />

applications. Tubing is color-coded to indicate i.d.<br />

PEEK Tubing Specifications<br />

Material:<br />

PEEK<br />

Maximum Temperature: 100°C<br />

Maximum Pressure: Varies by Size, See Price Block<br />

Typical Use:<br />

High-Pressure Plumbing<br />

5535<br />

Striped PEEK Tubing<br />

• No dye contacts fluid path<br />

Striped PEEK Tubing<br />

Maximum<br />

Pressure<br />

(psig)<br />

Striped<br />

Part No.<br />

Color o.d. i.d.<br />

Length<br />

Red 1/16" 0.005" 7,000 10' (3.05m) 35714<br />

50' (15.25m) 35715<br />

Yellow 1/16" 0.007" 7,000 10' (3.05m) 35712<br />

50' (15.25m) 35713<br />

Blue 1/16" 0.010" 5,000 10' (3.05m) 35702<br />

50' (15.25m) 35703<br />

Orange 1/16" 0.020" 5,000 10' (3.05m) 35708<br />

50' (15.25m) 35709<br />

Green 1/16" 0.030" 4,000 10' (3.05m) 35710<br />

50' (15.25m) 35711<br />

Grey 1/16" 0.040" 3,000 10' (3.05m) 35705<br />

50' (15.25m) 35707<br />

Black 1/16" 0.055" 1,000 10' (3.05m) 35741<br />

50' (15.25m) 35742<br />

0753A<br />

Solid Color PEEK Tubing<br />

• Entire tube is colored for faster<br />

identification<br />

Solid Color PEEK Tubing<br />

Maximum<br />

Pressure<br />

(psig)<br />

Solid<br />

Part No.<br />

Color o.d. i.d.<br />

Length<br />

Red 1/16" 0.005" 7,000 10' (3.05m) 35720<br />

50' (15.25m) 35721<br />

Yellow 1/16" 0.007" 7,000 10' (3.05m) 35722<br />

50' (15.25m) 35723<br />

Blue 1/16" 0.010" 5,000 10' (3.05m) 35728<br />

50' (15.25m) 35729<br />

Orange 1/16" 0.020" 5,000 10' (3.05m) 35726<br />

50' (15.25m) 35727<br />

Green 1/16" 0.030" 4,000 10' (3.05m) 35724<br />

50' (15.25m) 35725<br />

Natural 0.071" 0.030" 4,000 10' (3.05m) 35776<br />

50' (15.25m) 35778<br />

1/8" 0.062" 5,000 10' (3.05m) 35716<br />

50' (15.25m) 35717<br />

1/8" 0.080" 3,000 10' (3.05m) 35718<br />

50' (15.25m) 35719<br />

0753B<br />

related products<br />

Need high-pressure<br />

polymeric fittings?<br />

See pages 112–114<br />

for our full selection of<br />

high-pressure fittings.<br />

related products<br />

See page 391 for the<br />

Clean-cut tubing cutter<br />

designed to make clean<br />

square cuts on PEEK tubing.<br />

tubing<br />

6673<br />

5377<br />

384 www.discoverysciences.com


general chromatography<br />

Flex-Connect PEEK Tubing<br />

• Self-adjusting length<br />

• Will not bend or kink<br />

• PEEK construction is<br />

biocompatible and inert<br />

Flex-Connect is ideal for<br />

modular LC systems, giving<br />

you the freedom to move<br />

components without breaking<br />

connections. The coiled format<br />

springs back to keep excess<br />

tubing out of your way. Each piece has 6" of straight tubing<br />

at each end and comes with two 1-piece Hex-Head Fittings.<br />

Tubing is color-coded to indicate i.d.<br />

5527<br />

Flex-Connect Tubing stretches to make connections easier.<br />

Custom Flex-Connect Tubing<br />

Description<br />

Part No.<br />

Custom Flex-Connect Tubing* C-35800<br />

*Please specify the following when ordering: color coding (solid or striped), i.d.<br />

(0.005"–0.030"), and extended length (cm, 800cm max.).<br />

6264<br />

Striped Flex-Connect Tubing<br />

• No dye contacts fluid path<br />

Striped Flex-Connect PEEK Tubing<br />

Color o.d. i.d.<br />

Max. Pressure<br />

(psig) Size Range*<br />

Striped<br />

Part No.<br />

Red 1/16" 0.005" 7,000 1–5cm 35851<br />

2–10cm 35852<br />

3–15cm 35853<br />

5–25cm 35854<br />

10–50cm 35855<br />

15–75cm 35856<br />

Yellow 1/16" 0.007" 7,000 1–5cm 35861<br />

2–10cm 35862<br />

3–15cm 35863<br />

5–25cm 35864<br />

10–50cm 35865<br />

15–75cm 35866<br />

Blue 1/16" 0.010" 5,000 1–5cm 35871<br />

2–10cm 35872<br />

3–15cm 35873<br />

5–25cm 35874<br />

10–50cm 35875<br />

15–75cm 35876<br />

Orange 1/16" 0.020" 4,000 1–5cm 35881<br />

2–10cm 35882<br />

3–15cm 35883<br />

5–25cm 35884<br />

10–50cm 35885<br />

15–75cm 35886<br />

Green 1/16" 0.030" 4,000 1–5cm 35891<br />

2–10cm 35892<br />

3–15cm 35893<br />

5–25cm 35894<br />

10–50cm 35895<br />

15–75cm 35896<br />

*Size range indicates where coil is completely retracted and pulled to a comfortable<br />

distance. Excludes 6" straight piece on each end.<br />

0753A<br />

Solid Color Flex-Connect Tubing<br />

• Entire tube is colored for fast<br />

identification<br />

Solid Color Flex-Connect PEEK Tubing<br />

Color o.d. i.d.<br />

Max. Pressure<br />

(psig) Size Range*<br />

Solid<br />

Part No.<br />

Red 1/16" 0.005" 7,000 1–5cm 35801<br />

2–10cm 35802<br />

3–15cm 35803<br />

5–25cm 35804<br />

10–50cm 35805<br />

15–75cm 35806<br />

Yellow 1/16" 0.007" 7,000 1–5cm 35811<br />

2–10cm 35812<br />

3–15cm 35813<br />

5–25cm 35814<br />

10–50cm 35815<br />

15–75cm 35816<br />

Blue 1/16" 0.010" 5,000 1–5cm 35821<br />

2–10cm 35822<br />

3–15cm 35823<br />

5–25cm 35824<br />

10–50cm 35825<br />

15–75cm 35826<br />

Orange 1/16" 0.020" 4,000 1–5cm 35831<br />

2–10cm 35832<br />

3–15cm 35833<br />

5–25cm 35834<br />

10–50cm 35835<br />

15–75cm 35836<br />

Green 1/16" 0.030" 4,000 1–5cm 35841<br />

2–10cm 35842<br />

3–15cm 35843<br />

5–25cm 35844<br />

10–50cm 35845<br />

15–75cm 35846<br />

Natural 1/8" 0.062" 2,500 5–50cm 35807<br />

10–100cm 35808<br />

20–200cm 35809<br />

5–50cm 35827<br />

10–100cm 35828<br />

20–200cm 35829<br />

*Size range indicates where coil is completely retracted and pulled to a comfortable<br />

distance. Excludes 6" straight piece on each end.<br />

0753B<br />

tubing<br />

www.discoverysciences.com 385


general chromatography<br />

Stainless Steel Tubing<br />

Hi-EFF Tubing<br />

Hi-EFF grade stainless steel tubing is especially tempered<br />

for easy bending and is washed with acetone to remove any<br />

residual materials. Type 316 is recommended for plumbing<br />

LC systems.<br />

Stainless Steel Tubing<br />

This Stainless Steel Tubing is the same high quality as<br />

the Hi-EFF grade, but has not been washed with acetone.<br />

Type 316 is recommended for LC use.<br />

5562<br />

related product<br />

Looking for tubing cutters?<br />

Refer to page 391.<br />

Hi-EFF and Standard Stainless Steel Tubing Specifications<br />

Material:<br />

300 Series Stainless Steel<br />

Maximum Temperature: 500°C<br />

Maximum Pressure: Varies according to i.d.<br />

Typical Use:<br />

High-Pressure Plumbing<br />

Stainless Steel Tubing<br />

10ft (3m)*<br />

Part No.<br />

25ft (7.5m)*<br />

Part No.<br />

50ft (15m)* Coil<br />

Part No.<br />

200ft Coil<br />

Part No.<br />

o.d.<br />

i.d.<br />

Hi-EFF Type 316 Stainless Steel 1/8" (3.18mm) 0.085" (2.16mm) 5141338 5141342 30109 —<br />

1/4" (6.35mm) 0.210" (5.33mm) 5141337 5141343 30309 —<br />

Type 304 Stainless Steel 1/8" (3.18mm) 0.085" (2.16mm) 5141336 5141344 30106 —<br />

1/4" (6.35mm) 0.210" (5.33mm) 5141335 5141345 30306 —<br />

Standard Type 316 Stainless Steel 1/32" (0.79mm) 0.007" (0.18mm) 5141387 5141320 81951 —<br />

1/16" (1.59mm) 0.004" (0.10mm) 5141386 5141321 30212 —<br />

0.007" (0.18mm) 5141385 5141322 30142 —<br />

0.010" (0.25mm) 5141384 5141323 3005 30052<br />

0.020" (0.51mm) 5141383 5141324 3002 300220<br />

0.030" (0.76mm) 5141382 5141325 3000 300020<br />

0.040" (1.02mm) 5141381 5141326 3003 —<br />

0.050" (1.27mm) 5141380 5141327 3004 —<br />

Type 304 Stainless Steel 1/8" (3.18mm) 0.085 (2.16mm) 5141346 5141410 3010 30108<br />

1/16" (4.76mm) 0.147" (3.73mm) 5141332 5141413 3020 —<br />

1/4" (6.35mm) 0.210" (5.33mm) 5141333 5141412 3030 —<br />

1/8" (9.53mm) 0.305" (7.75mm) 5141334 5141411 3032 † —<br />

*Meters based on closest estimate; feet being exact. †40' coil.<br />

tubing<br />

EDM-Cut Stainless Steel Tubing<br />

• Highly polished, burr-free ends<br />

• Ultra-low volume connections<br />

• Ultrasonically cleaned and passivated for maximum inertness<br />

• Cut using an Electronic Discharge Machine (EDM)<br />

• Color-coded caps identify internal diameter<br />

EDM-Cut Stainless Steel Tubing Specifications<br />

Material:<br />

316 Grade Stainless Steel<br />

Maximum Temperature: 500°C<br />

Maximum Pressure: Varies according to i.d.*<br />

Typical Use:<br />

High-Pressure Plumbing<br />

EDM Cut<br />

0743 0744<br />

File Cut<br />

Abrasive Cut<br />

0745<br />

EDM-Cut Stainless Steel Tubing<br />

Cap Color i.d. (10/pk) Length Part No.<br />

Red 0.005" 4cm 97001<br />

5cm 97006<br />

10cm 97011<br />

20cm 97016<br />

30cm 97021<br />

Black 0.007" 5cm 97026<br />

10cm 97031<br />

20cm 97036<br />

30cm 97041<br />

Blue 0.010" 5cm 97046<br />

10cm 97056<br />

20cm 97061<br />

30cm 97066<br />

Green 0.020" 5cm 97076<br />

10cm 97081<br />

20cm 97086<br />

30cm 97091<br />

EDM-Cut Stainless Steel Tubing Kits<br />

6263<br />

EDM-Cut Stainless Steel Tubing Kits<br />

Description Tubing i.d. Part No.<br />

Standard Tubing Kit—Includes 10 pieces 5cm and 10cm tubing 0.005" 97132<br />

0.007" 97134<br />

0.010" 97136<br />

0.020" 97138<br />

0.030" 97141<br />

Deluxe Tubing Kit—10 pieces—5cm x 0.010, 10cm x 0.010, 5cm x 0.020, 10cm x 0.020<br />

5 pieces—2cm x 0.010, 2cm x 0.020<br />

2 pieces—5cm x 0.030, 10cm x 0.030, 20cm x 0.030<br />

Varies 97131<br />

386<br />

www.discoverysciences.com


general chromatography<br />

Low-Pressure Tubing<br />

Tefzel ® Tubing<br />

• Higher pressure rating<br />

compared to PTFE<br />

tubing<br />

Color-Coded<br />

PTFE Tubing<br />

• Color-coded for easy<br />

identification of i.d.<br />

5530<br />

5532<br />

Tefzel ® Tubing Specifications<br />

Material: Tefzel ®<br />

Maximum Temperature: 100°C<br />

Maximum Pressure:<br />

Typical Use:<br />

Varies by Size, See Price Block<br />

Low-Pressure Plumbing<br />

Tefzel ® Tubing<br />

o.d. i.d. Length psig Part No.<br />

1/16" 0.007" 10' 4000 35681<br />

1/16" 0.007" 50' 4000 35682<br />

1/16" 0.010" 10' 3600 35685<br />

1/16" 0.010" 50' 3600 35686<br />

1/16" 0.020" 10' 3200 35699<br />

1/16" 0.020" 50' 3200 35672<br />

1/16" 0.030" 10' 2500 35701<br />

1/16" 0.030" 50' 2500 35673<br />

Color-Coded PTFE Tubing Specifications<br />

Material:<br />

PTFE<br />

Maximum Temperature: 100°C<br />

Maximum Pressure:<br />

Typical Use:<br />

Varies by Size, See Price Block<br />

Low-Pressure Plumbing<br />

Color-Coded PTFE Tubing<br />

Color o.d. i.d. Length psig Part No.<br />

Blue 1/16" 0.010" 10' 1500 35660<br />

1/16" 0.010" 50' 1500 35661<br />

Orange 1/16" 0.020" 10' 1200 35662<br />

1/16" 0.020" 50' 1200 35663<br />

Green 1/16" 0.030" 10' 900 35664<br />

1/16" 0.030" 50' 900 35665<br />

PTFE Tubing<br />

• Maximum inertness<br />

PTFE Tubing Specifications<br />

Material:<br />

PTFE<br />

Maximum Temperature: 100°C<br />

Maximum Pressure:<br />

Typical Use:<br />

Varies by Size, See Price Block<br />

Low Pressure Plumbing<br />

PTFE Tubing<br />

o.d. i.d. Length psig Part No.<br />

1/16" 0.007" 10' 1600 35677<br />

1/16" 0.007" 50' 1600 35678<br />

1/16" 0.010" 10' 1500 20064<br />

1/16" 0.010" 50' 1500 35669<br />

1/16" 0.020" 10' 1200 20033<br />

1/16" 0.020" 50' 1200 35668<br />

1/16" 0.030" 10' 900 20031<br />

1/16" 0.030" 50' 900 35670<br />

1/16" 0.040" 10' 600 20106<br />

1/16" 0.040" 50' 600 3132<br />

1/8" 0.063" 10' 900 20063<br />

1/8" 0.063" 50' 900 35671<br />

1/8" 0.100" 10' 300 20096<br />

1/8" 0.100" 50' 300 3134<br />

0.160" 0.125" 10' 300 35667<br />

0.160" 0.125" 50' 300 35674<br />

1/4" 0.125" 50' 900 3136<br />

5531<br />

Low Permeation<br />

Tubing<br />

• Eliminates regassing<br />

without sacrificing<br />

inertness<br />

• Flexible, convenient,<br />

and versatile<br />

• Easy to install and use<br />

This low-pressure tubing has a double wall to prevent mobile<br />

phase regassing. The inert inner PTFE wall carries the mobile<br />

phase. The non-wetted outer wall is made from a translucent,<br />

flexible polymer with extremely low gas permeability. This low<br />

permeation tubing cuts regassing rates to negligible levels,<br />

while preserving PTFE’s chemical resistance, visibility, and<br />

handling properties. Use with low permeation fittings kit.<br />

Low Permeation Tubing Specifications<br />

Material:<br />

PTFE, Proprietary Non-Wetted Outer Layer<br />

Maximum Temperature: 100°C<br />

Maximum Pressure:<br />

Typical Use:<br />

900psig<br />

Low-Pressure Plumbing<br />

Low Permeation Tubing<br />

o.d. i.d. Length Part No.<br />

1/8" 1.5mm 10' 47100<br />

1/8" 1.5mm 50' 47102<br />

Low Permeation Fittings Kit<br />

Description<br />

Part No.<br />

1/4-28 Low Permeation Fittings Kit* 47120<br />

*Includes 10 nuts, 10 ferrules, 10 inserts.<br />

5533<br />

tubing<br />

www.discoverysciences.com 387


general chromatography<br />

Stainless Steel Tubing<br />

AT Steel—Activity Tested Steel Tubing<br />

Delivers the Strength of Stainless Steel and the Inertness of Deactivated Fused Silica<br />

• Flexible, and strong<br />

• Maximum temperature limit of 340°C–350°C<br />

A combination of chemical vapor deposition techniques and silicone chemistries transform durable<br />

stainless steel tubing into a chromatographically inert material. AT Steel activity tested steel tubing<br />

is suitable for sample loops, transfer lines, capillary, and packed GC columns.<br />

AT Steel may be cut with standard tubing cutters or high speed wheel cutters and can be rinsed with<br />

common solvents to remove particulates and contamination that have built up during use. To ensure a<br />

truly inert pathway, use AT Steel treated fittings. Sold separately below.<br />

5105<br />

AT Steel Tubing<br />

i.d. 6ft Length Part No. 25ft Length Part No. 50ft Length Part No. 100ft Length Part No.<br />

1/32" o.d. Tubing<br />

0.021" 11085 11086 11087 11088<br />

1/16" o.d. Tubing<br />

0.010" 11060 11061 11062 11063<br />

0.020" 11064 11065 11066 11067<br />

0.030" 11068 11069 11070 11071<br />

0.040" 11072 11073 11074 —<br />

1/8" o.d. Tubing<br />

0.085" 11076 11077 11078 —<br />

1/4" o.d. Tubing<br />

0.210" 11092 11093 — —<br />

AT Steel Unions<br />

Description<br />

Part No.<br />

1/8"–1/16" Reducing Union 11080<br />

1/16" Union 11081<br />

1/8" Union 11082<br />

AT Steel Tees<br />

Description<br />

Part No.<br />

1/16" Tee 11083<br />

1/8" Tee 11084<br />

Fittings are Parker-Hannifin ® A-Lok ® fittings with two-piece ferrules that have been<br />

chemically modified for improved inertness.<br />

Straight Stainless Steel Tubing<br />

• Type 304 Stainless Steel<br />

• 6ft or 10ft lengths<br />

Straight Stainless Steel Tubing<br />

o.d. i.d. Length* Qty. Part No.<br />

1/8" (3.18mm) 0.085" (2.16mm) 6ft 10 30106ST<br />

1/8" (3.18mm) 0.085" (2.16mm) 10ft 10 301010ST<br />

1/4" (6.35mm) 0.210" (5.33mm) 6ft 10 30306ST<br />

1/4" (6.35mm) 0.210" (5.33mm) 10ft 10 303010ST<br />

*10ft lengths must ship via motor freight.<br />

5097<br />

PTFE-Coated Stainless Steel Tubing<br />

• Sturdy SS tube with 0.001" thick<br />

PTFE coating<br />

• Must be preconditioned at 250°C for<br />

three hours<br />

PTFE-Coated Stainless Steel Tubing<br />

o.d. i.d. Length Part No.<br />

1/8" (3.18mm) 0.085" (2.16mm) per ft* 31421<br />

1/8" (3.18mm) 0.085" (2.16mm) 50ft 3142<br />

1/4" (6.35mm) 0.210" (5.33mm) per ft* 31441<br />

1/4" (6.35mm) 0.210" (5.33mm) 50ft 3144<br />

*Minimum tubing order is 3ft.<br />

5103<br />

tubing<br />

tech tip<br />

Choosing a tubing material for GC analysis.<br />

A number of options are available for packed column tubing. The most inert material is glass, which should be used for active compounds.<br />

Glass-lined tubing and AT Steel provide the inert surface of glass combined with the mechanical strength of a metal column.<br />

Metal tubing provides an economical and rugged column for suitable application. Passivated nickel tubing can frequently be used with<br />

active compounds such as phenols and amines. Stainless steel tubing is recommended for hydrocarbon, fixed gas, and solvent analyses<br />

where column inertness is less of a concern.<br />

PTFE tubing is extremely inert, but due to temperature limitations and poor column efficiency, PTFE is generally only recommended for<br />

the analysis of corrosive gases which are too reactive for glass.<br />

388<br />

www.discoverysciences.com


general chromatography<br />

Glass-Lined Stainless Steel<br />

Tubing (GLT)<br />

• Flow lines for corrosives<br />

• GC/MS interfaces<br />

PTFE-Lined Stainless Steel Tubing<br />

• Ideal for use with reactive chemicals and<br />

for trace quantities of water<br />

• Order PTFE ferrules to grip SS and PTFE<br />

portions of tubing below<br />

• Capillary column connections 5101 5102<br />

Glass-Lined Stainless Steel Tubing<br />

o.d. i.d. Length Part No.<br />

1/16" (1.59mm) 0.3mm 180cm 3137<br />

1/16" (1.59mm) 0.5mm 180cm 3164<br />

1/16" (1.59mm) 0.7mm 180cm 3139<br />

1/8" (3.18mm) 0.75mm 180cm 3166<br />

1/8" (3.18mm) 1.0mm 180cm 3168<br />

1/8" (3.18mm) 1.5mm 180cm 3170<br />

1/8" (3.18mm) 1.8mm 180cm 3141<br />

1/4" (6.35mm) 4.0mm 180cm 3149 • Maximum<br />

Inertness<br />

Metal Tubing<br />

Aluminum Tubing<br />

• Economical choice for GC gas lines<br />

Aluminum Tubing<br />

o.d. i.d. Length Part No.<br />

1/8" (3.18mm) 0.065" (1.65mm) 50ft 3090<br />

3/16" (4.76mm) 0.128" (3.25mm) 50ft 3100<br />

1/4" (6.35mm) 0.190" (4.83mm) 50ft 3110<br />

3/8" (9.53mm) 0.315" (8.00mm) 50ft 3120<br />

Copper Tubing<br />

• Economical choice for GC gas lines<br />

5106<br />

PTFE-Lined Stainless Steel Tubing<br />

o.d. i.d. Length Qty. Part No.<br />

1/8" (3.18mm) 0.070" (1.78mm) 6ft 1 3152<br />

1/8" (3.18mm) 0.070" (1.78mm) 10ft 1 3154<br />

1/4" (6.35mm) 0.180" (4.57mm) 6ft 1 3156<br />

Polymeric Tubing<br />

PFA (Perfluoroalkoxy) Tubing<br />

PFA FEP PTFE Polypropylene<br />

PFA (Perfluoroalkoxy) Tubing<br />

o.d. i.d. Length Part No.<br />

1/16" (1.59mm) 0.030" (0.76mm) 25ft 45734<br />

1/8" (3.18mm) 0.062" (1.57mm) 25ft 45735<br />

1/4" (6.35mm) 0.156" (3.96mm) 25ft 45736<br />

FEP (Fluorinated Ethylene Polypropylene)<br />

Tubing<br />

FEP (Fluorinated Ethylene Polypropylene) Tubing<br />

o.d. i.d. Length Part No.<br />

1/16" (1.59mm) 0.030" (0.76mm) 25ft 45739<br />

1/8" (3.18mm) 0.062" (1.57mm) 25ft 45740<br />

1/4" (6.35mm) 0.156" (3.96mm) 25ft 45741<br />

5104a<br />

Copper Tubing<br />

o.d. i.d. Length Part No.<br />

1/8" (3.18mm) 0.065" (1.65mm) 50ft 3040<br />

3/16" (4.76mm) 0.128" (3.25mm) 50ft 30509<br />

1/4" (6.35mm) 0.190" (4.83mm) 50ft 30609<br />

3/8" (9.53mm) 0.315" (8.00mm) 50ft 30709<br />

Nickel Tubing<br />

• Pure Nickel 200, more inert than<br />

stainless steel<br />

• Acid washed and rinsed for<br />

additional inertness<br />

Nickel Tubing<br />

o.d. i.d. Part No.<br />

50-Foot Coil<br />

1/16" (1.59mm) 0.010" (0.25mm) 3083<br />

1/16" (1.59mm) 0.020" (0.51mm) 3131<br />

1/16" (1.59mm) 0.040" (1.02mm) 3085<br />

1/8" (3.18mm) 0.083" (2.11mm) 3080<br />

1/4" (6.35mm) 0.210" (5.33mm) 3081<br />

200-Foot Coil<br />

1/16" (1.59mm) 0.010" (0.25mm) 30832<br />

1/16" (1.59mm) 0.020" (0.51mm) 31312<br />

5100<br />

5099<br />

Polypropylene/Polyethylene Tubing<br />

Polypropylene/polyethylene Tubing<br />

o.d. i.d. Type Length Part No.<br />

1/8" (3.18mm) 0.080" (2.03mm) PP 50ft 3203<br />

1/8" (3.18mm) 0.080" (2.03mm) PP 100ft 3201<br />

1/4" (6.35mm) 0.125" (3.17mm) PE 50ft 3207<br />

1/4" (6.35mm) 0.125" (3.17mm) PE 100ft 3205<br />

related products<br />

Need fittings?<br />

See pages 282–285 for a complete selection of<br />

GC fittings.<br />

tubing<br />

www.discoverysciences.com 389


general chromatography<br />

PEEKsil Tubing<br />

• Inert fused silica bonded to PEEK<br />

• Square cut and polished tubing ends<br />

for zero dead volume connections<br />

• Ideal for plumbing micro, capillary<br />

and nano LC systems<br />

SGE’s PEEKsil tubing maintains the<br />

easy handling and convenience of PEEK<br />

tubing, but offers the tight i.d. tolerances<br />

that can only be offered with fused silica.<br />

Each PEEKsil tubing end is cut to an exact 90° angle<br />

and polished smooth to ensure a true zero dead volume<br />

connection. Tubing is color-coded to identify i.d. It is the ideal<br />

choice for plumbing capillary and micro LC systems where<br />

conventional 1/16" or 1/32" fittings are used.<br />

6388<br />

Fused Silica Capillary Tubing<br />

• Tight size tolerances for<br />

maximum reproducibility<br />

• Easy to cut to desired<br />

length<br />

High quality fused silica tubing<br />

is commonly used to plumb<br />

capillary LC systems due to<br />

the size availability and extremely tight tolerances. All tubing<br />

below has 360µm outer diameter.<br />

Fused Silica Capillary Tubing Specifications<br />

Material:<br />

Polyimide-Coated Fused Silica<br />

Maximum Temperature: 350ºC<br />

Maximum Pressure:<br />

Typical Use:<br />

Limited by connection system<br />

Plumbing Capillary LC Systems<br />

6625<br />

tubing<br />

PEEKsil Tubing Specifications<br />

Material:<br />

Fused Silica-Lined PEEK<br />

Maximum Temperature: 100°C<br />

Typical Use:<br />

Plumbing Capillary LC Systems<br />

Maximum Pressure: 15,000psig<br />

PEEKsil Tubing, 1/16 o.d.<br />

10cm<br />

5/pk<br />

Part No.<br />

15cm<br />

5/pk<br />

Part No.<br />

Length<br />

20cm<br />

5/pk<br />

Part No.<br />

50cm<br />

2/pk<br />

Part No.<br />

Color i.d. (mm)<br />

Orange 0.025 226 227 228 229<br />

Natural 0.050 252 254 253 250<br />

Black 0.075 291 292 293 294<br />

Red 0.100 302 304 303 300<br />

Purple 0.150 231 232 233 234<br />

Yellow 0.175 352 354 353 350<br />

Blue 0.200 403 406 404 401<br />

Grey 0.300 416 417 418 419<br />

6389<br />

Fused Silica Capillary Tubing<br />

i.d.<br />

(mm)<br />

1 meter<br />

Part No.<br />

15 meter<br />

Part No.<br />

0.025 991100 —<br />

0.050 602035 —<br />

0.100 602036 —<br />

0.180 19603 602014*<br />

0.250 602600 602615<br />

0.320 603600 603615<br />

0.450 19602 —<br />

*Length for 0.180mm is 10 meter.<br />

Micro-Tubing<br />

• Consistent square cut for<br />

low volume connections<br />

Use micro-tubing for<br />

connecting fused silica<br />

capillaries to ensure proper<br />

low volume connections with<br />

your micro LC applications.<br />

Micro Tubing<br />

Color Reduction Part No.<br />

Red 1/16" to 127µm o.d. 3109278<br />

Yellow 1/16" to 178µm o.d. 3109280<br />

Natural 1/16" to 229µm o.d. 3109282<br />

Blue 1/16" to 280µm o.d. 3109283<br />

Orange 1/16" to 330µm o.d. 3109284<br />

Red 1/16" to 360µm o.d. 3109299<br />

Green 1/16" to 380µm o.d. 3109285<br />

Black 1/16" to 457µm o.d. 3109286<br />

Natural 1/16" to 533µm o.d. 3109287<br />

new<br />

7418<br />

7419<br />

390<br />

www.discoverysciences.com


general chromatography<br />

Tubing Cutters<br />

Rotary Tubing Cutter<br />

Heavy-duty Tubing Cutter<br />

• Inexpensive, well-built tool<br />

• Cuts 1/8" to 1-1/8" o.d. tubing<br />

• Works with metal tubing 5113<br />

Plier-type Tubing Cutters<br />

best<br />

seller<br />

• Cuts 1/32" to 1/8" o.d. tubing<br />

burr-free<br />

• Leaves tubing i.d. open<br />

• Works with metal and glass-lined tubing<br />

• Cuts 1/16" o.d. tubing<br />

• Ideal for cutting tubing in tight places<br />

• Cuts metal or plastic tubing<br />

5110<br />

Tubing Accessories<br />

Flex-wrap Tubing<br />

• Holds parallel tubing<br />

or wiring together<br />

• Ideal for gradient pumps<br />

or purging-gas lines<br />

• Chemically inert<br />

100% PTFE<br />

Flex-Wrap Tubing<br />

1/8"–1/2"<br />

Part No.<br />

3/16"–1"<br />

Part No.<br />

1/4"–2"<br />

Part No.<br />

Color<br />

Blue 35913 35923 35933<br />

Orange 35914 35924 35934<br />

Black 35916 35926 35936<br />

White 35917 35927 35937<br />

2357<br />

Ceramic Fused Silica Cutter<br />

• Cleanly cuts fused silica tubing<br />

• Small enough to keep handy in<br />

your pocket<br />

• Just score and snap<br />

3306<br />

Cable Turtles<br />

• Neat, easy way to organize messy cables<br />

• Patented “Turtle” stores and conceals excess cords<br />

Electric Tubing Cutter<br />

• Cut 1/16", 1/8", and 1/4" o.d. tubings<br />

with internal diameters as small<br />

as 0.008"<br />

• Requires no lubricant or cutting fluid<br />

• Assures square and burr-free cuts<br />

Clean-cut Tubing Cutter<br />

• Use with PTFE, Tefzel ® ,<br />

Polyolefin, PEEK<br />

• Make clean, square cuts without<br />

deforming inner diameters<br />

• Cuts 1/32" to 1/8" o.d.<br />

Plastic Tubing Cutter<br />

• Ideal for PEEK, Tefzel ® , and other<br />

plastic tubing<br />

• Cuts any size up to 1/4" o.d.<br />

Tubing Cutters<br />

Description Qty. Part No.<br />

Rotary Tubing Cutter ea 3165<br />

Replacement Cutting Wheels 3 3167<br />

Heavy-Duty Tubing Cutter ea 13995<br />

Replacement Cutting Wheels 3 13981<br />

Plier-Type Tubing Cutter ea 3169<br />

Ceramic Fused Silica Cutter 5 3194<br />

Electric Tubing Cutter 110–120/220–240VAC, 50/60Hz ea 10-0200<br />

Replacement Parts and Accessories<br />

Dressing Tool for 1/8" and 1/4" o.d. Tubing ea 10-0118<br />

Replacement Cutting Wheels 3 10-0124<br />

Replacement Dressing Tool for 1/16" o.d. Tubing ea 10-0116<br />

Clean-Cut Tubing Cutter ea 35902<br />

Replacement Blade ea 35903<br />

Plastic Tubing Cutter ea 3206<br />

Replacement Blade ea 3214<br />

4502<br />

6281<br />

5377<br />

5376<br />

Flexible rubber cup opens to let you coil extra cables, cords,<br />

tubing, or wires. Small Cable Turtle will holds up to 1 meter<br />

of standard appliance cord, and 3 meters of telephone wire.<br />

Large Cable Turtle holds up to 1 meter of thick instrument<br />

cord, 2 meters of standard appliance cord, or 6 meters of<br />

telephone wire.<br />

Cable Turtles<br />

Description Qty. Part No.<br />

Small<br />

Red 5/pk 5274<br />

Blue 5/pk 5276<br />

Black 5/pk 5278<br />

Grey 5/pk 5280<br />

Large<br />

Red 4/pk 5282<br />

Blue 4/pk 5284<br />

Black 4/pk 5286<br />

Grey 4/pk 5288<br />

4174<br />

tubing<br />

www.discoverysciences.com 391


general chromatography<br />

Organizers<br />

HPLC Columns and<br />

Accessories Organizers<br />

• Holds 10 HPLC columns<br />

• 17 compartments<br />

• PVC construction<br />

• 12" H x 24" W x 6" D<br />

(30.48cm H x 60.96cm W x 15.24cm D)<br />

HPLC Columns Organizers<br />

• 30 HPLC columns<br />

• Wall-mounts with two screws<br />

• PVC construction with acrylic<br />

doors<br />

• 17-3/8" H x 15" W x 2-7/8" D<br />

(44.18cm H x 38.1cm W x<br />

7.3cm D)<br />

Plastic Box with Removable<br />

Dividers<br />

• 13 removable dividers<br />

• Ideal for fittings and bore-cut<br />

tubing<br />

5507<br />

best<br />

seller<br />

5508<br />

GC Column and<br />

Accessory Organizers<br />

• 5-Column Organizer:<br />

13" H x 10.5" W x 14" L<br />

(33cm H x 26.5cm W x 35.5cm L)<br />

• 10-Column Organizer:<br />

12.75" H x 10.5" W x 25" L<br />

(32cm H x 26.5cm W x 63.5cm L)<br />

Organizer Box<br />

• 9-compartment organizer<br />

includes eight 1-3/8" x 1-5/8"<br />

(3.5cm x 4.13cm) slots and<br />

one 1-1/8" x 3-1/4" (2.8cm x<br />

8.2cm) slot<br />

• 18-compartment organizer<br />

includes twelve 2" x 2" (5cm x<br />

5cm) slots and six 2" x 4-3/16"<br />

(5cm x 10.6cm) slots<br />

5688<br />

5687<br />

5772<br />

Lab Organizer with Adjustable Bins<br />

• 14 adjustable dividers, 4 shelves<br />

• PVC construction<br />

• 20" H x 24" W x 10.5" D<br />

(50.8cm H x 60.9cm W x 26.7cm D)<br />

6348<br />

Organizers<br />

Description<br />

Part No.<br />

HPLC Supplies Organizer 5238<br />

HPLC Column Storage Unit 5240<br />

Plastic Storage Box with Removable Dividers 803880<br />

Lab Organizer with Adjustable Bins 5242<br />

GC Column and Accessory Organizers<br />

GC Column Organizer, 5-Column 6390<br />

GC Column Organizer, 10-Column 6392<br />

Organizer Box<br />

9-Compartment Box 6264<br />

18-Compartment Box 6266<br />

5509<br />

tools & organizers<br />

related products<br />

Looking for vial organizers<br />

and storage racks?<br />

See pages 380 and 381.<br />

3428 4954<br />

392<br />

www.discoverysciences.com


general chromatography<br />

Tools<br />

Magnifiers<br />

• For inspecting capillary column ends<br />

9-Way Wrench<br />

• For use with gas cylinders<br />

5178<br />

20X Magnifier<br />

Deluxe Torch Kit<br />

5325 2156<br />

Lighted Magnifying Glass<br />

• Ideal for sealing the ends of<br />

capillary columns<br />

• Kit contains the torch, six Micronox<br />

cylinders, three butane cylinders, six silver<br />

soldering rods, flux tube, two flame tips,<br />

one butane tip, one spark lighter, and<br />

complete instructions<br />

5181<br />

Miniature Files, Fine Cut<br />

• Set includes six differentshaped,<br />

5-1/2" long files<br />

• Made of hard chrome steel<br />

suitable for smoothing and<br />

deburring<br />

Miniature Reamers<br />

• Set includes six different sizes:<br />

0.028"/0.018", 0.040"/0.026",<br />

0.048"/0.032", 0.080"/0.050",<br />

0.085"/0.053", 0.104"/0.062"<br />

6279<br />

5324<br />

Capillary Tool Kit<br />

• Kit includes diamond scriber,<br />

two open end wrenches, PTFEcoated<br />

forceps, ruler, ferrule<br />

pick, 10' high temperature string,<br />

20X magnifier, and pipe cleaner<br />

23-Piece Tool Kit in Zippered Case<br />

• Kit includes seven screwdrivers, adjustable wrench, two<br />

pliers, wire stripper, knife, alignment<br />

tool, stainless rule, hex key set,<br />

scissors, two flexible files, burnisher,<br />

miniature soldering iron, solder aid,<br />

coil of solder, and desoldering braid<br />

Adjustable Wrench<br />

• Chrome-Plated<br />

Open-End Wrench<br />

• Chrome-Plated<br />

Handy-Lok Fitting Wrench<br />

• Ideal for connections on<br />

injection valves 5641<br />

5179<br />

5323<br />

5322<br />

5321<br />

Flame Checker<br />

• Pivoting mirror head fogs<br />

when flame is lit<br />

Tools<br />

Description Qty. Part No.<br />

Magnifier, 20X ea 3163<br />

Magnifier, Lighted (includes battery) ea 3196<br />

Deluxe Torch Kit 14606<br />

Micronox Cylinders 6/pk 14602<br />

Butane Cylinders 6/pk 14603<br />

Piercing Knob, Butane ea 14604<br />

Piercing Knob, Micronox ea 14605<br />

Capillary Tool Kit ea 16879<br />

23-Piece Tool Kit and Case ea 16533<br />

Adjustable Wrench<br />

4" Long—1/2" Capacity ea 16549<br />

6" Long—3/4" Capacity ea 3211<br />

8" Long—7/8" Capacity ea 16522<br />

Open-End Wrench<br />

1/4" x 5/16"—Fits 1/16" Fitting Nuts ea 1998<br />

7/16" x 1/2"—Fits 1/8" and 3/16" Fitting Nuts ea 1999<br />

9/16" x 5/8"—Fits 1/4" and 3/8" Fitting Nuts ea 2000<br />

Handy-Lok Fitting Wrench ea 35761<br />

9-Way Cylinder Wrench ea 412933<br />

Miniature Files, Fine Cut 6/pk 7237<br />

Miniature Reamers 6/pk 7330<br />

Flame Checker ea 7047<br />

5715<br />

tools and organizers<br />

www.discoverysciences.com 393


Applications<br />

HPLC Applications 395–453<br />

Pharmaceuticals 395–410<br />

Nutraceuticals/Vitamins 411–418<br />

Food & Beverage 419–428<br />

Life Science 429–443<br />

Environmental 444–447<br />

Miscellaneous 448–453<br />

IC Applications 454–461<br />

Anions 454–458<br />

Cations 459–460<br />

Surfactants 461<br />

GC Applications 462–493<br />

Drugs 462–467<br />

Environmental 468–476<br />

Foods, Flavors & Fragrances 476–481<br />

Petroleum & Petrochemical 481–485<br />

Solvents & Chemicals 485–493<br />

SPE Applications 494–502<br />

Pharmaceuticals 494<br />

Nutraceuticals 495–496<br />

Food & Beverage 497<br />

Life Science 498<br />

Environmental 499–502


hplc applications<br />

Analgesics<br />

Anti-Inflammatories<br />

Ibuprofen (U.S.P.)<br />

1<br />

2<br />

3<br />

4<br />

1. Naproxen<br />

2. Acemetacin<br />

3. Indomethacin<br />

4. p-Xylene<br />

8156 10702<br />

1<br />

2<br />

1. Valerophenone<br />

2. Ibuprofen<br />

pharmaceuticals<br />

0 2 4 6 8 10 Min.<br />

Column: Alltech ® Platinum C18, 5µm, 150 x 4.6mm<br />

(Part No. 32043)<br />

Mobile Phase: 0.02M KH2PO4:Methanol:Acetonitrile:<br />

pH4.5 (40:50:10)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

0<br />

2.5 5 7.5 10 12.5 15 17.5 20 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 150 x 4.6mm<br />

(Part No. 5138812)<br />

Mobile Phase: Phosphoric Acid in Water, pH2.5:Acetonitrile (65:35)<br />

Flow Rate: 2mL/min<br />

Detector: UV at 214nm<br />

Injection Vol: 5µL<br />

Analgesics<br />

10124<br />

1<br />

Analgesics<br />

9385<br />

1<br />

2<br />

3<br />

4<br />

6<br />

1. Aspirin<br />

2. Acetaminophen<br />

3. Naproxen<br />

4. Fenoprofen<br />

5. Ibuprofen<br />

6. Diclofenac<br />

2<br />

3 4<br />

1. Aspirin<br />

2. Acetaminophen<br />

3. Naproxen<br />

4. Fenoprofen<br />

5<br />

0 2<br />

4 6 8 10 Min.<br />

Column: Alltech ® Alltima C8, 5µm, 150 x 4.6mm (Part No. 88072)<br />

Mobile Phase: A: 0.05M K2HPO4, pH3.3 B: Methanol<br />

C: Acetonitrile<br />

Gradient: Time: 0 2 5<br />

%B: 10 10 30<br />

%C: 10 10 25<br />

Flow Rate: 2.0mL/min<br />

Detector: UV at 280nm<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: Alltech ® Prevail Amide, 5µm, 150 x 4.6mm<br />

(Part No. 88660)<br />

Mobile Phase: 0.02M K2HPO4, pH7.0:Acetonitrile (75:25)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 210nm<br />

2<br />

Basic Drugs<br />

Naproxen Enantiomers<br />

10374 8769<br />

1<br />

3<br />

1. Procainamide<br />

2. Acetaminophen<br />

3. Theophylline<br />

4. Caffeine<br />

CH 3<br />

CHCOH<br />

4<br />

H 3 CO<br />

O<br />

0 3 6 9 12 15 Min. 6 8 10 12 Min.<br />

Column: Alltech ® Alltima HP C8, 5µm, 150 x 4.6mm<br />

Column: Astec Chirobiotic ® V, 250 x 4.6mm (Part No. 11024)<br />

(Part No. 87751)<br />

Mobile Phase: 0.1% Triethylammonium Acetate (TEAA), pH7.0:<br />

Mobile Phase: 0.05M Phosphate Buffer pH3.0:Methanol (80:20)<br />

Tetrahydrofuran (90:10)<br />

Flow Rate: 1.0mL/min<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Detector: UV at 254nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

395


hplc applications<br />

pharmaceuticals<br />

Analgesics<br />

1<br />

2<br />

0 2 4 6 8 10 Min.<br />

2<br />

3<br />

3<br />

Analgesics<br />

1. Solvent front<br />

2. Acetaminophen (Paracetamol)<br />

3. Codeine phosphate<br />

Column: Jones Genesis ® C18, 4µm, 100 x 4.6mm<br />

(Part No. FM10960E)<br />

Mobile Phase: Acetonitrile:25mM KH2PO4, pH3.0 (10:90)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Steroids<br />

Steroids<br />

1<br />

1. Hydrocortisone<br />

2. Testosterone<br />

3. Progesterone<br />

9392<br />

mAU<br />

2000<br />

1750<br />

1500<br />

1250<br />

1000<br />

750<br />

500<br />

250<br />

0<br />

0<br />

1<br />

Paracetamol Effervescent Tablets on<br />

Chinese Pharmacopeia Assay<br />

1 2 3 4 5 6 7 8 9 10 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

2<br />

3 4<br />

5<br />

Corticosteroids<br />

6<br />

7<br />

1. Paracetamol<br />

10770<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Phosphate Buffer:Methanol (80:20)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

10391<br />

1. Deoxycorticosterone<br />

Acetate<br />

2. Hydrocortisone Acetate<br />

3. Cortisone Acetate<br />

4. Cortisone<br />

5. Prednisone<br />

6. Hydrocortisone<br />

7. Prednisolone<br />

0 1 Min.<br />

Column: Alltech ® Prevail C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 99279)<br />

Mobile Phase: Water:Methanol (10:90)<br />

Flow Rate: 4.5mL/min<br />

Detector: UV at 254<br />

0<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 Min.<br />

Column: Alltech ® Alltima HP CN, 5µm, 150 x 4.6mm<br />

(Part No. 87769)<br />

Mobile Phase: Hexane:Isopropanol (93.7:6.3)<br />

Flow Rate: 2.0mL/min<br />

Detector: UV at 254nm<br />

3<br />

Hydrocortisone Acetate Cream<br />

9463<br />

Estropipate Sample<br />

10423<br />

1<br />

1. Methyl Paraben<br />

2. Propyl Paraben<br />

3. Hydrocortisone Acetate<br />

1. Estrone Sulfate<br />

2. Piperazine<br />

1<br />

2<br />

2<br />

0 1 2 3 4 5 Min.<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208)<br />

Mobile Phase: Water:Acetonitrile (10:90)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 Min.<br />

Column: Alltech ® Alltima CN, 5µm, 250 x 4.6mm (Part No. 88189)<br />

Mobile Phase: 0.15% Nitric Acid:Acetonitrile (5:95)<br />

Flow Rate: 0.5mL/min<br />

Detector: ELSD<br />

396<br />

www.discoverysciences.com


hplc applications<br />

Antidepressants<br />

Tricyclic Amines<br />

Alprazolam and Triazolam by the USP XXII Method<br />

1<br />

2<br />

3<br />

1. Fluphenazine HCl<br />

2. Chlorpromazine HCl<br />

3. Phenothiazine HCl<br />

9105<br />

1<br />

2<br />

1. Triazolam<br />

2. Alprazolam<br />

7368<br />

pharmaceuticals<br />

0 1<br />

2<br />

3<br />

2<br />

4 5 6 7 8 Min.<br />

Column: Alltech ® Alltima CN, 3µm, 150 x 4.6mm<br />

(Part No. 81189)<br />

Mobile Phase: 0.01M KH2PO4, pH2.6:Acetonitrile (50:50)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

3<br />

Basic Drugs<br />

1. Diphenhydramine<br />

2. Nortriptyline<br />

3. Amitriptyline<br />

10353<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

1<br />

2<br />

Alltech ® Alltima Silica, 5µm, 300 x 4.6mm (Custom)<br />

Acetonitrile:Chloroform:i-Butyl Alcohol:Water:Glacial<br />

Acetic Acid (85:8:5:2:0.05)<br />

2.0mL/min<br />

UV at 254nm<br />

Tricyclic Antidepressants<br />

4<br />

1. Desipramine<br />

2. Nortryptyline<br />

3. Diphenhydramine<br />

4. Amitriptyline<br />

10373<br />

1<br />

3<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

0<br />

2 4 6 8 10 12 14 16 18 20 22 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

1. Chlordiazepoxide Degradant<br />

2. Nitrazepam<br />

3. Norchlordiazepoxide<br />

4. Nordiazepam<br />

3<br />

2<br />

5<br />

4<br />

1<br />

Alltech ® Alltima HP C18 Amide, 5µm, 150 x 4.6mm<br />

(Part No. 87733)<br />

0.025M Potassium Phosphate Buffer, pH7.0:Methanol<br />

(15:85)<br />

1mL/min<br />

UV at 254nm<br />

Benzodiazepines and Metabolites<br />

6<br />

8691<br />

5. Chlordiazepoxide<br />

6. Chlordiazepoxide Degradant<br />

7. Diazepam<br />

7<br />

Column: Alltech ® Alltima HP C8, 5µm, 150 x 4.6mm<br />

(Part No. 87751)<br />

Mobile Phase: A: 0.025M Potassium Phosphate Buffer, pH7.0<br />

B: Methanol<br />

Gradient: Time: 0 8 20<br />

%B: 60 75 75<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

1<br />

Universal High Speed Gradient<br />

2<br />

3<br />

4<br />

5<br />

8957<br />

1. Theophylline<br />

2. Acetylsalicylic Acid<br />

3. Propranolol<br />

4. Nortriptyline<br />

5. Trimipramine<br />

0 2<br />

4 6 Min.<br />

Column: Alltech ® Platinum EPS C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 50573)<br />

Mobile Phase: 0.05M Ammonium Acetate, pH5.5:Acetonitrile (65:35)<br />

Flow Rate: 3.0mL/min<br />

Detector: UV at 254nm<br />

0 1 2 3 4 5 6 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 50605)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.1% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 6<br />

%B: 10 90<br />

Flow Rate: 2.5mL/min<br />

Detector: ELSD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

397


hplc applications<br />

pharmaceuticals<br />

Antidepressants<br />

1<br />

2<br />

3<br />

4<br />

Propanolol<br />

0 1 2 3 4 5 6 7 8 Min.<br />

10719<br />

1. Uracil<br />

2. Propanolol<br />

3. Naphthalene<br />

4. Dipropylphthalate<br />

Column: <strong>Grace</strong> ® VisionHT C18, 1.5µm, 50 x 2.0mm<br />

(Part No. 5139605)<br />

Mobile Phase: 20mM Potassium Phosphate, pH2.5:Methanol (40:60)<br />

Flow Rate: 0.5mL/min<br />

Detector: UV at 280nm<br />

Temperature: Ambient<br />

1<br />

2<br />

3<br />

4<br />

Propanolol<br />

0 1 2 3 4 5 6 7 8 Min.<br />

1. Uracil<br />

2. Propanolol<br />

3. Naphthalene<br />

4. Dipropylphthalate<br />

10720<br />

Column: <strong>Grace</strong> ® VisionHT C18-P, 1.5µm, 50 x 2.0mm<br />

(Part No. 5139606)<br />

Mobile Phase: 20mM Potassium Phosphate, pH2.5:Methanol (40:60)<br />

Flow Rate: 0.5mL/min<br />

Detector: UV at 280nm<br />

Temperature: Ambient<br />

1<br />

2<br />

3<br />

Basic Drugs<br />

Basic Drugs<br />

4<br />

5<br />

6<br />

1. Amiloride<br />

2. Propranolol<br />

3. Chloramphenicol<br />

4. Carbamazepine<br />

5. Trimipramine<br />

6. Trifluoperazine<br />

Barbiturates<br />

2<br />

1<br />

3<br />

4<br />

5<br />

Barbiturate Mix<br />

1. Barbital<br />

2. Phenobarbital<br />

3. Talbutal<br />

4. Amobarbital<br />

5. Mephobarbital<br />

10375<br />

0 1 2 3 4 5 6 7 Min.<br />

Column:<br />

GENESIS Jones FM15960E Genesis (C18, ® C18, 4 4µm, 4.6 150 mm i.d. x 4.6mm x 150 mm)<br />

Flow:<br />

2.0 mL/min (Part No. FM15960E)<br />

Mobile Eluent: Phase: Isocratic, Acetonitrile:50mM 35% ACN in mM KH2PO4, 2 POpH2.4 4 , 2.4 (35:65)<br />

Temp: 40 °C<br />

Flow Rate: 2.0mL/min<br />

Detection: Absorbance, 254 nm<br />

Detector: UV at 254nm<br />

Peaks: 1. Amiloride, 2. Propranolol, 3. Chloramphenicol,<br />

4. Carbamazepine, 5. Trimipramine, 6. Trifluoperazine<br />

0<br />

2 4 6 8 10 12 14 16 18 20 Min.<br />

Column: Alltech ® Alltima HP C8, 5µm, 250 x 4.6mm<br />

(Part No. 87751)<br />

Mobile Phase: 0.05M Ammonium Acetate:Acetonitrile (78:22)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 230nm<br />

Barbiturate Mix<br />

Barbiturate Mix<br />

10604 8684<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6 7<br />

1. Phenobarbital<br />

2. Butabarbital<br />

3. Butalbital<br />

4. Pentobarbital<br />

5. Amobarbital<br />

6. Mephobarbital<br />

7. Secobarbital<br />

1<br />

2<br />

3<br />

4 5 6<br />

7<br />

8<br />

1. Barbital<br />

2. Butalbarbital<br />

3. Aprobarbital<br />

4. Talbutal<br />

5. Butabarbital<br />

6. Phenobarbital<br />

7. Amobarbital<br />

8. Mephobarbital<br />

0 2 4 6 8 10 12 14 16 18 Min.<br />

0 1<br />

2 3 4 Min.<br />

Column: Alltech ® Alltima HP C18 HiLoad, 5µm, 250 x 4.6mm<br />

(Part No. 87698)<br />

Mobile Phase: Water:Acetonitrile (70:30)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column: Alltech ® Platinum EPS C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 50575)<br />

Mobile Phase: 0.01M Sodium Acetate, pH4.0:Acetonitrile (75:25)<br />

Flow Rate: 3.0mL/min<br />

Detector: UV at 230nm<br />

398<br />

www.discoverysciences.com


hplc applications<br />

Barbiturates<br />

2<br />

4<br />

1 3<br />

5<br />

Barbiturate Mix<br />

1. Primidone<br />

2. Metharbital<br />

3. Mephenytoin<br />

4. Phenobarbital<br />

5. Phenytoin<br />

10164<br />

Anticonvulsants<br />

Anticonvulsants<br />

3<br />

4<br />

2<br />

1<br />

1. Ethotoin<br />

2. Mephenytoin<br />

3. Carbamazepine<br />

4. Diazepam<br />

9394<br />

pharmaceuticals<br />

0 2<br />

4 6 8 10 12 Min. 0 2<br />

4 6 8 Min.<br />

Column: ZirChrom ® DiamondBond-C18, 3µm, 100 x 4.6mm<br />

(Part No. DB01-1046)<br />

Mobile Phase: 0.05M Ammonium Phosphate, pH7.0:Tetrahydrofuran<br />

(75:25)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220<br />

Column: Alltech ® Prevail Phenyl, 5µm, 150 x 4.6mm<br />

(Part No. 99239)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 15<br />

%B: 25 60<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 254<br />

Anticonvulsants<br />

Anticonvulsants<br />

10348 10349<br />

1<br />

2<br />

1. Ethotoin<br />

2. Phenytoin<br />

3. Mephenytoin<br />

4. Carbamazepine<br />

3 4 0 2 4 6 8 10 12 14 16 18 20 Min.<br />

1<br />

2<br />

3<br />

4<br />

1. Ethotoin<br />

2. Phenytoin<br />

3. Mephenytoin<br />

4. Carbamazepine<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Min.<br />

Column: Alltech ® Alltima HP EPS C18, 5µm, 150 x 4.6mm<br />

(Part No. 87715)<br />

Mobile Phase: 0.025M Ammonium Acetate:Acetonitrile (70:30)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column: Alltech ® Alltima HP C18 HiLoad, 5µm, 150 x 4.6mm<br />

(Part No. 87697)<br />

Mobile Phase: 0.025M Ammonium Acetate:Acetonitrile (70:30)<br />

Anti-Anginal Drugs<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Anti-Anginals<br />

Anticonvulsants<br />

Anticonvulsants<br />

2<br />

3<br />

1. Uracil<br />

2. Carbamazepine<br />

3. Phenytoin<br />

1<br />

2<br />

Anti-Anginal Drugs<br />

3<br />

4<br />

1. Atenolol<br />

2. Metoprolol<br />

3. Propranolol<br />

4. Diltiazem<br />

1<br />

0 1 2 3 4 5 Min.<br />

0 1 2 3 4 5 Min.<br />

Column: Jones Genesis ® Phenyl, 4µm, 50 x 4.6mm<br />

Column: GENESIS FM5980E (Phenyl, 4 µm, 4.6 mm i.d. x 50 mm)<br />

(Part No. FM5980E)<br />

Flow:<br />

1.0 mL/min<br />

Mobile Eluent: Phase: Isocratic, Methanol:Water 30% MeOH in (30:70) water<br />

Flow Detection: Rate: Absorbance, 1.0mL/min 210 nm<br />

Detector:<br />

Peaks: 1. Uracil, UV at 2. 210nm Carbamazepine, 3. Phenytoin<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

Column: Column: GENESIS Jones Genesis FM10960E<br />

® C18, 4µm, 100 x 4.6mm<br />

(C18, (Part 4 No. µm, FM10960E)<br />

4.6 mm i.d. x 100 mm)<br />

Mobile Flow: Phase: 1.0 Acetonitrile:50mM mL/min<br />

KH2PO4, pH3.0 (40:60)<br />

Flow Eluent: Rate: Isocratic, 1.0mL/min 40% ACN in 50 mM KH 2 PO 4 , pH 3.0<br />

Detector: Detection: Absorbance, UV at 254nm 254 nm<br />

Peaks: 1. Atenolol, 2. Metoprolol, 3. Propranolol, 4. Diltiazem<br />

ww.discoverysciences.com<br />

399


hplc applications<br />

pharmaceuticals<br />

Antihistamines<br />

1<br />

2<br />

3<br />

4<br />

Antihistamines<br />

5<br />

1. Tripelennamine<br />

2. Triprolidine<br />

3. Cyclizine<br />

4. Chlorcyclizine<br />

5. Meclizine<br />

Antihistamines<br />

7232 4<br />

10163<br />

1<br />

2<br />

3<br />

5<br />

1. Tripelennamine<br />

2. Triprolidine<br />

3. Cyclizine<br />

4. Pyrrobutamine Phosphate<br />

5. Meclizine<br />

0 5 10 15 20 25 Min.<br />

0 1<br />

2<br />

3<br />

4<br />

5<br />

6 Min.<br />

Column: Alltech ® Alltima C8, 5µm, 250 x 4.6mm (Part No. 88076)<br />

Mobile Phase: A: 0.05M Potassium Phosphate, pH3.2<br />

B: Acetonitrile<br />

Gradient: Time: 0 5 20 25<br />

%B: 25 25 70 70<br />

Flow Rate: 1.3mL/min<br />

Detector: UV at 220nm<br />

Column: ZirChrom ® PS, 3µm, 50 x 4.6mm (Part No. ZR09-0546)<br />

Mobile Phase: A: Acetonitrile<br />

B: 25mM Hydrochloric Acid<br />

Gradient: Time: 0 1.0 1.1 4.0<br />

%B: 95 85 80 40<br />

Antihistamines<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254<br />

Antihistamines<br />

Wide-pore reversed-phase columns can have advantages for smallmolecule<br />

separations. Wide-pore Here a reversed-phase Vydac ® 218TP columns 300Å can C18 have advantages column separated<br />

for<br />

a mixture of antihistamines small-molecule in the separations. same time Here as a VYDAC a 90Å 218TP C18 300 column, Å C18 but<br />

with less organic solvent column in separated the gradient a mixture and of antihistamines better resolution. in the same time<br />

as a 90 Å C18 column, but with less organic solvent in the gradient<br />

Column:<br />

and better resolution.<br />

Vydac ® C18, 300Å, 5µm, 100 x 4.6mm<br />

(Part No. 218TP5410)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.1% Trifluoroacetic Acid in Acetonitrile<br />

Gradient (A): Time: 0 10<br />

%B: 5 35<br />

Gradient (B): Time: 0 10<br />

%B: 10 40<br />

Flow Rate: 2.5mL/min<br />

Detector: UV at 260nm<br />

(a)<br />

(b)<br />

1<br />

2<br />

1<br />

2<br />

3<br />

3<br />

4<br />

4<br />

5<br />

5<br />

VYDAC ® 218TP5410<br />

300 Å C18<br />

0 2 4 6 8 10 Min.<br />

6<br />

7<br />

VYDAC ® 201TP5410<br />

90 Å C18<br />

6,7<br />

1. Pheniramine<br />

2. Doxylamine<br />

3. Methapyraline<br />

4. Chlorpheniramine<br />

5. Orphenadrine<br />

6. Diphenylpyraline<br />

7. Promethazine<br />

1<br />

2<br />

OTC Antihistamine and Excipients<br />

3<br />

4 5<br />

1. Diphenhydramine<br />

2. PEG, Gelatin<br />

3. Sorbitan<br />

4. Glycerol<br />

5. Sorbitol<br />

10275<br />

Columns: VYDAC 218TP5410 (300 Å) C18, 5 µm, 4.6 mm i.d. x 100mm<br />

Flow:<br />

2.5 mL/min<br />

Eluent: Estrogens A = 0.1% (v/v) TFA in H 2 O B = 0.1% (v/v) TFA in ACN<br />

Gradient: a) 5% to 35% B in 10 Estrogens<br />

min b) 10% to 40% B in 10 min<br />

Detection: Absorbance, 260 nm<br />

Peaks: 1) pheniramine; 2) doxylamine; 3) methapyraline;<br />

4) chlorpheniramine; Estrogens 5) orphenadrine; 6) diphenylpyraline;<br />

7) promethazine<br />

1. Estriol<br />

2. 17α-Ethylestradiol<br />

3. Estrone<br />

4. Diethylstilbestrol<br />

5. Hexestrol<br />

6. Product of Diethylstilbestrol<br />

Decomposition<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

400<br />

0 1 2 3 4 5 6 7 8 9 10 11 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: Acetonitrile:0.1% Ammonium Carbonate, pH6.5 (80:20)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

www.discoverysciences.com<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

Column: Vydac ® Denali ® , 5µm, 150 x 4.6mm (Part No. 238DE5415)<br />

Column: DENALI 238DE5415 (5 µm, 4.6 mm i.d. x 150 mm)<br />

Mobile Phase: A: Acetonitrile:Water (20:80)<br />

Flow:<br />

1.0 mL/min<br />

Eluent: A = B: 20% Acetonitrile:Water ACN in water (95:5)<br />

Gradient: B = Time: 95% ACN in 0 water 8<br />

Gradient: Linear, %B: 40% to 40 90% 90 B over 8 min<br />

Flow Temp: Rate: Ambient, 1.0mL/min 22 °C<br />

Detector:<br />

Detection: Absorbance, UV at 280nm<br />

nm<br />

Sample: 20 µL containing 150 ppm of each analyte<br />

Peaks: 1. Estriol, 2. 17a-Ethylestradiol, 3. Estrone,<br />

4. Diethylstilbestrol, 5. Hexestrol,<br />

6. product of Diethylstilbestrol decomposition.


hplc applications<br />

Anesthetics<br />

1 + 2<br />

3<br />

Basic Pharmaceuticals<br />

1. Procaine<br />

2. Lidocaine<br />

3. Tetracaine<br />

1 2<br />

Basic Pharmaceuticals<br />

10737 10738<br />

3<br />

1. Procaine<br />

2. Lidocaine<br />

3. Tetracaine<br />

pharmaceuticals<br />

0 0.5 1 1.5 2 2.5 3 Min.<br />

Column: <strong>Grace</strong> ® VisionHT C18, 1.5μm, 50 x 2.0mm<br />

(Part No. 5139605)<br />

Mobile Phase: 25mM Potassium Phosphate, pH7.0:Methanol (30:70)<br />

Flow Rate: 0.5mL/min<br />

Detector: UV at 230nm<br />

0 0.5 1 1.5 2 2.5 3 Min.<br />

Column: <strong>Grace</strong> ® VisionHT C18-P, 1.5μm, 50 x 2.0mm<br />

(Part No. 5139606)<br />

Mobile Phase: 25mM Potassium Phosphate, pH7.0:Methanol (30:70)<br />

Flow Rate: 0.5mL/min<br />

Detector: UV at 230nm<br />

Anesthetic Mix<br />

Anesthetics<br />

Anesthetics<br />

4<br />

10118<br />

3<br />

1<br />

2<br />

3<br />

5<br />

1. p-Aminobenzoic Acid<br />

2. Benzocaine<br />

3. Tetracaine<br />

4. Dibucaine<br />

5. Butacaine<br />

1<br />

2<br />

4<br />

5<br />

6<br />

1. Procaine<br />

2. Benzocaine<br />

3. Mepivacaine<br />

4. Lidocaine<br />

5. Tetracaine<br />

6. Dibucaine<br />

0<br />

2 4 6 8 10 12 Min.<br />

3<br />

0 10 20 30 40 50 60 Min.<br />

Column: Alltech ® Alltima C8, 5µm, 150 x 4.6mm (Part No. 88072) Column: Vydac ® Denali ® , 5µm, 150 x 4.6mm (Part No. 238DE5415)<br />

Mobile Phase: A: Water B: Methanol C: Acetonitrile<br />

Mobile Phase: Methanol:50mM K2HPO4 in Water, pH7.0 (60:40)<br />

Gradient: Time: 0 7<br />

Column: Flow Rate: DENALI 238DE5415 1.0mL/min (5 µm, 4.6 mm i.d. x 150 mm)<br />

%B: 15 45<br />

Flow:<br />

Detector:<br />

1.0 mL/min<br />

UV at 220nm<br />

Eluent: Isocratic, 60:40 MeOH:H 2 O containing<br />

%C: 15 35<br />

50 mM K 2 HPO 4 , pH 7<br />

Flow Rate: 1.5mL/min<br />

Temp: 30 °C<br />

Detector: UV at 230nm<br />

Detection: Absorbance, 220 nm<br />

Peaks: 1. Procaine, 2. Benzocaine, 3. Mepivacaine,<br />

4. Lidocaine, 5. Tetracaine, 6. Dibucaine<br />

Opiates<br />

Opiates<br />

10165<br />

Opiates<br />

1<br />

2<br />

4<br />

1. Naloxone<br />

2. Codeine<br />

3. Ethylmorphine<br />

4. Oxycodone<br />

1<br />

3<br />

Opiates<br />

1. Hydromorphone<br />

2. Oxycodone<br />

3. Codeine<br />

4. Ethylmorphine<br />

5. Nalorphine<br />

2<br />

4<br />

5<br />

0 1 2 3 4 5 Min. 0 5 10 15 20 25 Min.<br />

Column: ZirChrom ® DiamondBond-C18, 3µm, 100 x 4.6mm Column: Vydac ® Denali ® , 5µm, 250 x 4.6mm (Part No. 238DE54)<br />

(Part No. DB01-1046)<br />

Mobile Column: Phase: DENALI Methanol:20mM 238DE54 (5 µm, K2HPO4 4.6 mm in i.d. Water, x 250 mm) pH7.0 (50:50)<br />

Mobile Phase: 0.02M Ammonium Phosphate, pH11.0:<br />

Flow: Rate: 1.0 1.0mL/min<br />

Tetrahydrofuran (73.5:26.5)<br />

Detector:<br />

Eluent: Isocratic,<br />

UV at<br />

50:50<br />

254<br />

MeOH:H 2 O containing<br />

20 mM K 2 HPO 4 , pH 7<br />

Flow Rate: 1.0mL/min<br />

Temp: Ambient at 22 °C<br />

Detector: UV at 220<br />

Detection: Absorbance, 254 nm<br />

Sample: 10 µL containing 10 µg of each analyte<br />

more applications<br />

Peaks: 1.Hydromorphone, 2. Oxycodone, 3. Codeine,<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

4. Ethylmorphine, 5. Nalorphine ww.discoverysciences.com<br />

401


hplc applications<br />

Anti-Hypertensives<br />

Antihypertensives<br />

Basic Drugs<br />

pharmaceuticals<br />

1 2<br />

3<br />

1. Metoprolol<br />

2. Oxprenolol<br />

3. Propranolol<br />

9395<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

1. Labetalol<br />

2. Acebutolol<br />

3. Oxprenolol<br />

4. Lidocaine<br />

5. Alprenolol<br />

6. Propranolol<br />

10161<br />

0 1 2 Min.<br />

Column: Alltech ® Prevail C18, 3µm, 53 x 7mm (Part No. 99279)<br />

Mobile Phase: 0.025M KH2PO4, pH3.0:Acetonitrile (70:30)<br />

Flow Rate: 4.0mL/min<br />

Detector: UV at 220<br />

0 1 2 3 4 5 Min.<br />

Column: ZirChrom ® PBD, 3µm, 150 x 4.6mm (Part No. ZR03-1546)<br />

Mobile Phase: 0.01M Triethylamine, 0.05M Tetramethylammonium<br />

Hydroxide, pH12.2:Acetonitrile (65:35)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254<br />

Calcium Channel Blockers<br />

1<br />

10356<br />

Drug Mix<br />

10354<br />

2<br />

3<br />

4<br />

1. Diltiazem<br />

2. Verapamil<br />

3. Nicardipine<br />

4. Nifedipine<br />

2<br />

3<br />

1. Codeine<br />

2. Strychnine<br />

3. Quinine<br />

4. Quinidine<br />

1<br />

4<br />

0 1 2 3 4 5 6 7 8 9 10 Min.<br />

Column: Alltech ® Alltima HP CN, 5µm, 150 x 4.6mm<br />

(Part No. 87769)<br />

Mobile Phase 0.02M KH2PO4, pH3.0:Acetonitrile (70:30)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 218nm<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 Min.<br />

Column: Alltech ® Alltima HP C18 Amide, 5µm, 150 x 4.6mm<br />

(Part No. 87733)<br />

Mobile Phase: 0.025M Potassium Phosphate, pH2.8:Methanol (90:10)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Sedatives<br />

2<br />

1<br />

3<br />

4<br />

5<br />

0 2 4 6 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Sedatives/Hypnotics<br />

1. Barbital<br />

2. Phenobarbital<br />

3. Butalbital<br />

4. Oxazepam<br />

5. Triazolam<br />

8160<br />

Alltech ® Platinum C18, 5µm, 150 x 4.6mm<br />

(Part No. 32043)<br />

0.05M Ammonium Dihydrogen Orthophosphate, pH4.5:<br />

Methanol:Acetonitrile (40:50:10)<br />

1.0mL/min<br />

UV at 230nm<br />

mAU<br />

Statins<br />

180<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

0<br />

Simvastatin Tablets (U.S.P.)<br />

<strong>Grace</strong>Smart C18<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

Competitor 4 C18<br />

2 4 6 8 10 12 14 16 Min.<br />

10708<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: 0.39% Sodium Phosphate Monobasic, pH4.5:<br />

Acetonitrile (35:65)<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 238nm<br />

402<br />

www.discoverysciences.com


hplc applications<br />

Anti-Asthmatics<br />

Methylxanthines<br />

1 2<br />

3<br />

4<br />

5<br />

8384 8679<br />

1. Theobromine<br />

1. Xanthine<br />

2. Theophylline<br />

2. Theobromine<br />

3. 8-Chlorotheophylline<br />

3. Theophylline<br />

4. Caffeine<br />

4. Caffeine<br />

5. 7-(2-Chloroethyl)theophylline 1<br />

5. 8-Chlorotheophylline<br />

6. 7-(2-Chloroethyl)theophylline<br />

2<br />

3 4 5<br />

Theophylline & Metabolites<br />

6<br />

pharmaceuticals<br />

0 2 4 6 8 10 Min.<br />

Column: Alltech ® Platinum EPS C18, 100Å, 5µm, 150 x 4.6mm<br />

(Part No. 32214)<br />

Mobile Phase: Water:Acetonitrile:Methanol:Glacial Acetic Acid (60:10:30:1)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

0 1<br />

2 3 Min.<br />

Column: Alltech ® Platinum EPS C18, 3µm, 33 x 7mm Rocket<br />

(Part No. 50575)<br />

Mobile Phase: 0.010M Sodium Acetate, pH4.0:Methanol (70:30)<br />

Flow Rate: 5.0mL/min<br />

Detector: UV at 254nm<br />

Amphetamines<br />

1 2<br />

3<br />

MDA and MDMA Analogs<br />

4<br />

1. 2,3-MDA<br />

2. 3,4-MDA<br />

3. 2,3-MDMA<br />

4. 3,4-MDMA<br />

10427<br />

1<br />

2<br />

MDA & MDMA Analogs<br />

1. 2,3-MDA<br />

2. 3,4-MDA<br />

3. 2,3-MDMA<br />

4. 3,4-MDMA<br />

10014<br />

3 4<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

Column: Alltech ® Alltima HP Silica, 3µm, 150 x 4.6mm<br />

(Part No. 87786)<br />

Mobile Phase: 1%Ammonium Hydroxide in Methanol:Acetonitrile (75:25)<br />

Flow Rate: 1.0mL/min<br />

Column Temp: 25°C<br />

Detector: UV at 280nm<br />

0 1 2 3 4 Min.<br />

Column: Alltech ® Alltima Silica, 3µm, 100 x 4.6mm<br />

(Part No. 81404)<br />

Mobile Phase: 1%Ammonium Hydroxide in Methanol:Acetonitrile (25:75) 1) Doxorubucine<br />

Flow Rate: 2.0mL/min<br />

2) Daunorubicine<br />

Detector: UV at 280nm<br />

Antiseptics<br />

0 1<br />

Highly Polar Cosmetic Ingredients<br />

2<br />

1<br />

2<br />

3 4 5 Min.<br />

1. Allantoin<br />

2. Bronopol<br />

Column: ZirChrom ® CARB, 3µm, 100 x 4.6mm<br />

(Part No. ZR01-1046)<br />

Mobile Phase: Water:Acetonitrile (80:20)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 200nm<br />

10166<br />

Chemotherapeutics<br />

Rubicines - Chemotherapeutics<br />

1<br />

2<br />

1. Doxorubucine<br />

2. Daunorubicine<br />

0 5 10 15 20 Min.<br />

Column: Grom Sil 120 ODS-3 CP, 5μm, 125 x 3mm<br />

(Part No. 5113604)<br />

Mobile Phase: A: 25mM Sodium Phosphate, pH2.2 B: Acetonitrile<br />

Gradient: Time: 0 12 20<br />

%B: 0 60 60<br />

Flow Rate: 0.45mL/min<br />

Detector: Fluorescence at 480nm (exc.), 560nm (em.)<br />

Rubicines - Chemotherapeut<br />

Column phase: GROM-SIL 1<br />

Column size: 125 x 3mm<br />

Eluent A: 25 mM Na-phosph<br />

B: ACN<br />

Gradient: 0-60% B (0-12 mi<br />

Flow rate: 0.45 ml/min<br />

Pressure: 19 MPa<br />

Temperature: 28°C<br />

Detection (Fluor): 480 nm (e<br />

Injection: 100 µl (100 ng/ml<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

403


hplc applications<br />

pharmaceuticals<br />

Diuretics<br />

2<br />

1<br />

4<br />

3<br />

10<br />

7<br />

5 6 8 9<br />

12<br />

11<br />

13<br />

14<br />

15<br />

Diuretics and Uricosuric Agents<br />

1. Amiloride HCl Hydrate<br />

2. Acetazolamide<br />

3. Hydrochlorothiazide<br />

4. Triamterene<br />

5. Chlorthalidone<br />

6. Furosemide<br />

7. Hydroflumethiazide<br />

8. Clopamide<br />

9. Ethacrynic Acid<br />

10. Trichloromethiazide<br />

11. Probenecid<br />

12. Indapamide<br />

13. Bumetanide<br />

14. Bendroflumethiazide<br />

15. Spironolactone<br />

10246<br />

0<br />

5 10 15 20 25 30 Min.<br />

Column: Alltech ® Alltima C18, 5µm, 250 x 4.6mm (Part No. 88056)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in 0.025M Ammonium Acetate B: 0.1% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 30<br />

%B: 25 65<br />

11<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

10<br />

1<br />

2 3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

12<br />

Doping Agents<br />

1. Amiloride HCl Hydrate<br />

2. Acetazolamide<br />

3. Hydrochlorothiazide<br />

4. Chlorthalidone<br />

5. Hydroflumethiazide<br />

6. Clopamide<br />

7. Trichloromethiazide<br />

8. Indapamide<br />

9. Bendroflumethiazide<br />

10. Bumetanide<br />

11. Probenecid<br />

12. Spironolactone<br />

10262<br />

0<br />

1 2 3 4 5 6 7 8 9 10 11 12 Min.<br />

7<br />

Column: Alltech ® Alltima C18, 5µm, 250 x 4.6mm (Part No. 88056)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in 0.025M Ammonium Acetate B: 0.1% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 10 15<br />

%B: 25 95 95<br />

Flow Rate: 1.0mL/min<br />

3<br />

5 6 6. Trichloromethiazide<br />

7. Indapamide<br />

Detector: ELSD<br />

8<br />

Diuretics — High Throughput<br />

1. Acetazolamide<br />

2. Hydrochlorothiazide<br />

10265<br />

1<br />

9<br />

3. Triamterene<br />

4. Hydroflumethiazide<br />

5. Clopamide<br />

8. Bumetanide<br />

9. Spironolactone<br />

2 4<br />

0<br />

1 2 3 4 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 53 x 7mm Rocket (Part No. 50605)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in 0.025M Ammonium Acetate B: 0.1% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 4<br />

%B: 20 95<br />

Flow Rate: 3.5mL/min<br />

Detector: UV at 254nm<br />

404<br />

www.discoverysciences.com


hplc applications<br />

Antibiotics<br />

Antibacterials<br />

Antibacterials<br />

1<br />

2<br />

3 4<br />

5<br />

1. Sulfanilamide<br />

2. Cefaclor<br />

3. Cefatrizine<br />

4. Thiamphenicol<br />

5. Cefotaxime<br />

8711 8764<br />

3<br />

1. Oxytetracycline<br />

Dihydrate<br />

1<br />

2. Tetracycline HCl<br />

2<br />

3. Meclocycline<br />

Sulfosalicylate Salt<br />

pharmaceuticals<br />

0 2<br />

4 6 8 10 Min.<br />

Column: Alltech ® Platinum EPS C18, 5µm, 150 x 4.6mm<br />

(Part No. 32043)<br />

Mobile Phase: 0.025M KH2PO4, pH3.0:Acetonitrile (90:10)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 230nm<br />

0 2 4 6 8 10 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 100 x 4.6mm (Part No. 81382)<br />

Mobile Phase: A: 0.05M KH2PO4, pH3.0 B: Acetonitrile<br />

Gradient: Time: 0 10<br />

%B: 15 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Aminoglycoside Antibiotics<br />

Antibacterials<br />

2<br />

1<br />

3<br />

4<br />

1. Streptomycin<br />

2. Amikacin<br />

3. Tobramycin<br />

4. Neomycin<br />

9210<br />

1<br />

2<br />

3<br />

6<br />

4<br />

5<br />

9<br />

7 8<br />

11<br />

10<br />

1. Neomycin<br />

2. Amoxicillin<br />

3. Vancomycin<br />

4. Cefatrizine<br />

5. Metampicillin<br />

6. Cefotaxime<br />

7. Unknown<br />

8. Bacitracin<br />

9. Pipericillin<br />

10. Bacampicillin<br />

11. Oxacillin<br />

9396<br />

0 1<br />

2<br />

3<br />

4<br />

5 6 7 8 9 Min.<br />

0 2<br />

4 6 8 10 12 14 16 18 20 22 Min.<br />

Column: Alltech ® Alltima C18, 5µm, 250 x 4.6mm (Part No. 88056)<br />

Mobile Phase: 0.3% Pentafluoropropionic Acid in 43.7mM Ammonium<br />

Formate, pH2.7:0.3% Pentafluoropropionic Acid in<br />

Methanol (45:55)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208)<br />

Mobile Phase: A: 0.025M KH2PO4, pH3.0 B: Acetonitrile<br />

Gradient: Time: 0 15 22<br />

%B: 10 40 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 210<br />

Tylosin and Monensin<br />

Sulfa Drugs<br />

10319 10351<br />

1<br />

1. Tylosin (400ppm)<br />

2. Monensin (180ppm)<br />

1<br />

1. Sulfanilamide<br />

2. Sulfamerazine<br />

3. Sulfamethazine<br />

4. Sulfamethizole<br />

2<br />

2 3 4<br />

0 1 2 3 4 5 Min.<br />

Column: Alltech ® Prevail Select C18, 5µm, 150 x 4.6mm<br />

(Part No. 99300)<br />

Mobile Phase: Ammonium Hydroxide in Water, pH9.0:Acetonitrile (5:95)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Min.<br />

Column: Alltech ® Alltima HP C18 HiLoad, 5µm, 150 x 4.6mm<br />

(Part No. 87697)<br />

Mobile Phase: 0.1% Phosphoric Acid:Acetonitrile (85:15)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

405


mAU<br />

hplc applications<br />

pharmaceuticals<br />

Antibiotics<br />

1<br />

2<br />

Antibiotics via HILIC<br />

0 5 10 15 20 25 30 35 40 45 Min.<br />

3<br />

1. Amikacin<br />

2. Tobramycin<br />

3. Neomycin<br />

10626<br />

1 2 3 45 6 7<br />

8<br />

Column: Alltech ® Alltima HP HILIC, 5µm, 150 x 1) 4.6mm Bacampiccillin Column: <strong>Grace</strong> ® VisionHT C18-P, 1.5µm, 50 x 2.0mm<br />

(Part No. 86464)<br />

2) Methicillin<br />

(Part No. 5139606)<br />

Mobile Phase: Acetonitrile:Methanol:Water (87:11:2) 3) Benzylpenicillin Mobile Phase: A: 0.1% Formic Acid B: Methanol<br />

Flow Rate: 1.0mL/min<br />

4) Phenoxymethylpenicillin Gradient: Time: 0 1.4<br />

Detector: ELSD<br />

5) Phen-oxyethylpenicillin<br />

%B: 20 100<br />

6) Phenoxypropylpenicillin Flow Rate: 0.4mL/min<br />

7) Cloxacillin Detector: UV at 280nm<br />

Penicillin Antibiotics<br />

8) Propicillin<br />

9) Proicillin<br />

10) Dicloxacillin<br />

Analysis of Vancomycin<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Sulfa Drugs<br />

1. Sulfadiazine<br />

2. Sulfathiazole<br />

3. Sulfamerazine<br />

4. Sulfamethazine<br />

5. Sulfamethoxazole<br />

6. Sulfaisoxazole<br />

7. Sulfaquinoxilone<br />

8. Sulfamethoxine<br />

0 1 2 3 4 5 Min.<br />

2<br />

1. Bacampicillin<br />

1. N-Dimethylvancomycin<br />

2. Methicillin Penicillin Antibiotics<br />

2<br />

2. Vancomycin1) N-Dimethylvancomycin<br />

1 3<br />

3. Benzylpenicillin<br />

10<br />

2) Vancomycin<br />

4<br />

4. Phenoxymethylpenicillin<br />

7<br />

5. Phen-oxyethylpenicillin<br />

6. Phenoxypropylpenicillin<br />

Column phase: GROM-SIL ODS-7 pH, 4 µm<br />

Column phase: GROM-SIL 100<br />

Column size: 150 x 4.0 mm<br />

5 6 7. Cloxacillin<br />

8 9 Column size: 250 x 4 mm<br />

8. Propicillin Eluent 50 mM NaH2PO4 pH 2.3<br />

9. Proicillin<br />

Eluent : 0.1% H PO / ACN = 15<br />

Flow rate: 0.75 ml/min<br />

10. Dicloxacillin<br />

1<br />

Flow rate: 1.0 ml/min<br />

Pressure: 17 MPa<br />

Pressure: 13 MPa<br />

Temperature: 37°C<br />

Temperature: ambient<br />

Detection (UV): 220 nm<br />

0 3 6 9 12 15 18 21 24 27 30 33 Min.<br />

0 2 4 6 8 10 12 14 16 18 20 22 Min. Detection (UV): 210 nm<br />

Injection: 8 µl (~ 0.13 mg/ml of each)<br />

Column: Grom Sil ODS-7 pH, 4μm, 150 x 4mm<br />

Column: Grom Sil 100 ODS-0 AB, 5μm, 250 x 4mm<br />

Injection: 10 µl (10 µg/ml)<br />

Mobile Phase: 50mM Monosodium Phosphate, pH2.3<br />

Mobile Phase: 0.1% Phosphoric Acid:Acetonitrile (15:85)<br />

Flow Rate: 0.75mL/min<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

Detector: UV at 210nm<br />

10724<br />

0 2<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Erythromycin<br />

8630<br />

1<br />

1. Erythromycin<br />

4 6 8 10 Min.<br />

Alltech ® Macrosphere 300 C4, 7µm, 250 x 4.6mm<br />

(Part No. 71039)<br />

Acetonitrile: 0.2M Ammonium Acetate in Water,<br />

pH4.5 (95:5)<br />

1.0mL/min<br />

ELSD<br />

mAU<br />

6000000<br />

5500000<br />

5000000<br />

4500000<br />

4000000<br />

3500000<br />

3000000<br />

2500000<br />

2000000<br />

1500000<br />

1000000<br />

500000<br />

-500000 0<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Amoxicillin (U.S.P.)<br />

0 1 2 3 4 5 6 7 Min.<br />

<strong>Grace</strong>Smart C18 Column<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

Competitor 4 C18<br />

<strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm<br />

(Part No. 5138810)<br />

0.05N Monobasic Potassium Phosphate, pH5.0:<br />

Acetonitrile (96:4)<br />

1.5mL/min<br />

UV at 230nm<br />

10697<br />

406<br />

www.discoverysciences.com


hplc applications<br />

Bacitracin<br />

Bacitracin<br />

0 1 2 3 4 5 6 7 8 Min.<br />

0 1<br />

Spectinomycin<br />

1<br />

1. Spectinomycin<br />

2 3 4 5 6 7 8 9 Min.<br />

10680<br />

pharmaceuticals<br />

Column:<br />

GENESIS Jones FM15960E Genesis ® (C18, C18, 4 4µm, 4.6150 mm x i.d. 4.6mm x 150 mm)<br />

Flow:<br />

1.0 mL/min (Part No. FM15960E)<br />

Mobile Eluent: Phase: 31% Acetonitrile:0.1% ACN/0.1% TFA in water Trifluoroacetic Acid (31:69)<br />

Flow Detection: Rate: Absorbance, 1.0mL/min 214 nm<br />

Detector: UV at 214nm<br />

Column: Alltech ® Alltima HP C18 Amide, 3µm, 50 x 4.6mm<br />

(Part No. 87829)<br />

Mobile Phase: 10mM Ammonium Carbonate:Acetonitrile (98:2)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

mAU<br />

100<br />

80<br />

60<br />

40<br />

Clarithromycin on<br />

Chinese Pharmacopeia Assay<br />

1. Clarithromycin<br />

10760<br />

mAU<br />

500<br />

400<br />

300<br />

200<br />

Clindamycin Hydrochloride on<br />

Chinese Pharmacopeia Assay<br />

1. Clindamycin<br />

10768<br />

20<br />

100<br />

0<br />

0<br />

2 4 6 8 10 12 14 16 18 Min.<br />

Competitor 1 C18<br />

Competitor 4 C18<br />

Competitor 2 C18<br />

Competitor 5 C18<br />

Competitor 3 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Phosphate Buffer (Dissolve 9.11g Potassium Dihydrogen<br />

Phosphate in 1000mL Water, add 2mL Triethylamine, adjust<br />

with Phosphoric Acid to pH of 5.5):Acetonitrile (60:40)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 210nm<br />

0<br />

0 2 4 6 8 10 12 14 Min.<br />

Competitor 1 C18<br />

Competitor 4 C18<br />

Competitor 2 C18<br />

Competitor 5 C18<br />

Competitor 3 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:Ammonium Dihydrogen Phosphate Solution<br />

(Dissolve 2.88g Ammonium Dihydrogen Phosphate in<br />

1000mL Water, adjust with Phosphoric Acid to pH3.0)<br />

300:210<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 214nm<br />

mAU<br />

1400<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

0<br />

0<br />

Ceftriaxone Sodium on<br />

Chinese Pharmacopeia Assay<br />

1. Ceftriaxone<br />

5 10 15 20 25 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10776<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: 0.02mol/L n-Octylamine:Acetonitrile (73:27)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

mAU<br />

700<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

0<br />

0<br />

Cefradine on<br />

Chinese Pharmacopeia Assay<br />

1. Ceftriaxone<br />

5 10 15 20 25 30 35 40 45 50 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10767<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Water:Methanol:3.86% Sodium Acetate:4% Acetic Acid<br />

(1564:400:30:6)<br />

Flow Rate: 0.9mL/min<br />

Detector: UV at 254nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

407


hplc applications<br />

pharmaceuticals<br />

Bronchodilators<br />

Bronchodilators<br />

Bronchodilators<br />

3<br />

4<br />

1<br />

5<br />

1. Uracil<br />

2. Salbutamol<br />

3. Terbutaline<br />

4. Theophylline<br />

5. Pseudoephedrine<br />

1<br />

2<br />

3<br />

Analysis of Broncholytics -<br />

Xanthines<br />

4<br />

5<br />

1. Theobromine<br />

2. Theophylline<br />

3. β-Hydroxyethyltheophylline<br />

4. 7-β-Hydroxypropyltheophyline<br />

5. Caffeine<br />

2<br />

0 1 2 3 4 Min.<br />

Column: Jones Genesis ® Phenyl, 4µm, 150 x 4.6mm<br />

Column: GENESIS (Part FM15980E No. FM5980E) (Phenyl, 4 µm, 4.6 mm i.d. x 150 mm)<br />

Flow: Mobile Phase: 2.0 mL/min Acetonitrile:25mM KH2PO4, pH3.0 (10:90)<br />

Eluent: Flow Rate: Isocratic, 2.0mL/min 10% ACN in 25 mM KH 2 PO 4 , pH3.0<br />

Detection: Detector: Absorbance, UV at 220nm<br />

Peaks: 1. Uracil, 2. Salbutamol, 3. Terbutaline, 4. Theophylline,<br />

5. Pseudoephedrine<br />

Xanthines<br />

2<br />

1<br />

3<br />

4<br />

5<br />

6 7<br />

0 2 4 6 8 10 Min.<br />

1. Uracil<br />

2. Theobromine<br />

3. Impurity<br />

4. Sodium Benzoate<br />

5. Theophylline<br />

6. b-Ethoxytheophylline<br />

7. Caffeine<br />

Xanthines<br />

0 3 6 9 12 Min.<br />

Column: Grom Sil 120 ODS-4 HE, 5μm, 250 x 4mm<br />

(Part No. 5113626)<br />

Mobile Phase: 0.4% Sodium Acetate:Acetonitrile (85:15)<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 254nm<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Jones Genesis ® C18, 4µm, 150 x 4.6mm<br />

(Part No. FM15960E)<br />

Acetonitrile:50mM Aqueous Ammonium Acetate, pH4.7<br />

(12:88)<br />

1.0mL/min<br />

UV at 254nm<br />

Column: GENESIS FM15960E (C18, 4 µm, 4.6 mm i.d. x 150 mm)<br />

Flow:<br />

1.0 mL/min<br />

Eluent: Antifungal Isocratic, 12% ACN in 50 mM NH 4 OAc, pH 4.7<br />

Detection: Absorbance, 254 nm<br />

Lotrimin ® Topical Assay<br />

Peaks: 1. Uracil, 2. Theobromine, 3. Impurity, 4. Sodium Benzoate,<br />

5. Theophylline, 6. b-Ethoxytheophylline, 7. Caffeine<br />

1<br />

2<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 Min.<br />

1. PEG<br />

2. Clotrimazole<br />

10447<br />

Column: Alltech ® Alltima C18, 5µm, 150 x 4.6mm (Part No. 88302)<br />

Mobile Phase: A: Water to pH7.0 with Acetic Acid B: Methanol<br />

Gradient: Time: 0 8 10 20 25<br />

%B: 30 50 100 100 30<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

mAU<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

Griseofulvin Assay on Chinese Pharmacopeia<br />

0<br />

1. Griseofulvin<br />

2.5 5 7.5 10 12.5 15 17.5 20 22.5 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10772<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: 0.05mol/L Potassium Dihydrogen Phosphate:<br />

Acetonitrile:Methanol (57:38:5)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

408<br />

www.discoverysciences.com


hplc applications<br />

Taxols<br />

Taxol ® and Related Taxanes in Yew<br />

Taxanes<br />

1. 10-Deacetylbaccatin III<br />

2. Baccatin III<br />

3. 7-Xylosyl-10-deacetyltaxol B<br />

4. Taxinine M<br />

5. 7-Xylosyl-10-deacetyltaxol<br />

6. 7-Xylosyl-10-deacetyltaxol C<br />

1<br />

2<br />

4,5 6<br />

3<br />

7<br />

8 9<br />

10 11<br />

7. 10-Deacetyltaxol<br />

8. 7-Xylosyltaxol<br />

9. Cephalomannine (Taxol ® B)<br />

10. 7-Epi-10-deacetyltaxol<br />

11. Taxol ®<br />

12. Taxol ® C<br />

13. 7-Epitaxol<br />

12 13<br />

9221<br />

1. 10-Deacetylbaccatin III<br />

2. Baccatin III<br />

3. 10-Deacetyl-7-xylosyltaxol B<br />

4. Taxinine M<br />

5. 10-Deacetyl-7-xylosyltaxol<br />

6. 10-Deacetyl-7-xylosyltaxol C<br />

7. 10-Deacetyltaxol<br />

8. 7-Xylosyltaxol<br />

1<br />

2<br />

3 4<br />

a<br />

5 6 8 10 11<br />

7 9<br />

Taxanes<br />

12 13<br />

9. Cephalomannine<br />

10. 10-Deacetyl-7-epitaxol<br />

11. Taxol ®<br />

12. Taxol ® C<br />

13. 7-Epitaxol<br />

b<br />

Peaks:<br />

a. 3’-Fluorophenyl-10-deacetyltaxol<br />

b. 3’-Fluorophenyltaxol<br />

pharmaceuticals<br />

1. 10-deacetylbaccatin III<br />

2. baccatin III<br />

3. 10-deacetyl-7-xylosyltaxol<br />

4. taxinine M<br />

5. 10-deacetyl-7-xylosyltaxol,<br />

6. 10-deacetyl-7-xylosyltaxol<br />

7. 10-deacetyltaxol<br />

8. 7-xylosyltaxol<br />

9. cephalomannine<br />

10. 10-deacetyl-7-epitaxol,<br />

11. paclitaxel<br />

12. taxol C<br />

13. 7-epitaxol<br />

a. 3’-fluorophenyl-10-deacety<br />

b. 3’-fluorophenyltaxol<br />

0 1<br />

2<br />

3<br />

4<br />

5 6<br />

7<br />

8 Min. 0 10 20 30 40 50 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Alltech ® Alltima Phenyl 3µm, 53 x 7mm Rocket<br />

(Part No. 81174)<br />

0.05% Trifluoroacetic Acid:Methanol:Acetonitrile<br />

(50:19:31)<br />

2.5mL/min<br />

UV at 230nm<br />

Columns: VYDAC 218MS54 C18, 5 µm, 4.6 mm i.d. x 250mm<br />

Column: Flow:<br />

1.0 Vydac mL/min<br />

® C18, 5µm, 250 x 4.6mm (Part No. 218MS54)<br />

Mobile Eluent: Phase: A A: = 50 50mM NaOAc, Sodium pH Acetate, 6.8 pH6.8 B: Acetonitrile<br />

Gradient: B Time: = acetonitrile 0 2 32 42 42<br />

Gradient: Hold 34% B for 2 min, then linear to 44% B over<br />

%B: 34 34 44 60 100<br />

30 min, then linear to 60% B over 10 min,<br />

Flow Rate: then 1.0mL/min linear to 100% B in 10 min<br />

Detector: Detection: Absorbance, UV at 254nm<br />

nm<br />

Preparative Paclitaxel Purification<br />

Antiviral<br />

Aciclovir Assay on<br />

Chinese Pharmacopeia<br />

10764<br />

mAU<br />

3000<br />

2000<br />

1000<br />

0<br />

10 grams of 633N C18 slurried with 20ml of Isopropanol<br />

• ?Slurry used to pack a 10 mm i.d.x200mm length column<br />

• ?80/20 Methanol/Water used to elute the target compound<br />

?Fraction analyzed with a <strong>Grace</strong> Denali® C18 analytical column<br />

0<br />

Low Pressure Preparative Chromatography with <strong>Grace</strong><br />

Davisil<br />

®<br />

633N C18 (10g) 10 mm i.d.x200mm Column<br />

20.0<br />

100% NeOH (v/v): 0.0%<br />

100% H2O (v/v): 100.0%<br />

80.0<br />

50.0<br />

50.0<br />

80.0<br />

20.0<br />

10 20 30 40 50<br />

100.0<br />

0.0<br />

45ml of Paclitaxel<br />

Fraction Collected<br />

60 70 80 Min.<br />

mAU<br />

450<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

0<br />

1. Aciclovir<br />

2 4 6 8 10 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Silica: <strong>Grace</strong> ® Davisil ® C18, 50µm (Part No. 5134095)<br />

Column: 10mm i.d. x 200mm Length<br />

Sample: 10g of powdered yew bark extract<br />

Mobile Phase: See Chromatogram<br />

Detector: UV at 230nm<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:Water (10:90)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

409


hplc applications<br />

pharmaceuticals<br />

mAU<br />

Calcium Channel Blockers<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

0<br />

Flunarizine Hydrochloride Capsules on<br />

Chinese Pharmacopeia Assay<br />

2 4 6 8 10 12 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10761<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:Phosphate Buffer (Dissolve 1.36g Potassium<br />

Dihydrogen Phosphate in 1000mL Water, add 4mL<br />

Triethylamine, adjust with Phosphoric Acid to pH3.5)<br />

(75:25)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 253nm<br />

mAU<br />

250<br />

1. Flunarizine 200<br />

1. Nimodipine<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

150<br />

100<br />

50<br />

0<br />

0<br />

Nimodipine Tablets on<br />

Chinese Pharmacopeia Assay<br />

2 4 6 8 10 12 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10763<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:Acetonitrile:Water (35:38:27)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 237nm<br />

mAU<br />

Beta Blockers<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

0<br />

1. Atenolol<br />

5 10 15 20 25 30 35 Min.<br />

Atenolol Assay on Chinese Pharmacopeia<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10777<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: 700mL Phosphate Buffer (6.8g Potassium Dihydrogen<br />

Phosphate in 1000mL Water, adjust pH3.0 with<br />

Phosphoric Acid), add Methanol 300mL and Sodium<br />

1-Octanesulfonate 1.30g<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 275nm<br />

Histamine Receptor Antagonists<br />

Famotidine Tablets on<br />

Chinese Pharmacopeia Assay<br />

mAU<br />

700<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

0<br />

0<br />

2 4 6 8 10 12 14 16 18 20 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10779<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Sodium 1-Heptanesulfate solvent (2.0g Sodium<br />

1-Heptanesulfate in 900mL Water, adjust to pH 3.9<br />

with Acetic Acid):Acetonitrile:Methanol (25:6:1)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

250<br />

1. Famotidine 1. Naloxone<br />

200<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Narcotic Analgesic Antagonists<br />

Naloxone Hydrochloride Injection<br />

on Chinese Pharmacopeia Assay<br />

300<br />

mAU<br />

150<br />

100<br />

50<br />

0<br />

0<br />

2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10778<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Sodium 1-octanesulfonate solvent (1.36g Sodium<br />

1-octanesulfonate, 1.0g Sodium Chloride in 580mL<br />

Water):Methanol:Phosphoric Acid (580:420:1)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 229nm<br />

410<br />

www.discoverysciences.com


hplc applications<br />

0<br />

Ginseng<br />

1<br />

2<br />

Ginsenosides in Korean Ginseng<br />

3<br />

4<br />

5<br />

6<br />

7 8 10<br />

9<br />

1. Rh2<br />

2. Rh1<br />

3. Rg2<br />

4. Rg3<br />

5. Rg1<br />

6. Rf<br />

11<br />

7. Re<br />

8. Rd<br />

9. Rc<br />

10. Rb2<br />

11. Rb1<br />

20 40 60 Min.<br />

10142<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile:Water:Isopropyl Alcohol (80:5:15)<br />

B: Acetonitrile:Water:Isopropyl Alcohol (67:21:12)<br />

Gradient: Time: 0 28 35 45 50 51 57<br />

%B: 25 85 80 75 90 100 25<br />

Flow Rate: 0.8mL/min<br />

Detector: ELSD<br />

600000<br />

500000<br />

400000<br />

300000<br />

200000<br />

100000<br />

0<br />

-100000<br />

40<br />

12<br />

50 60 70 80 90 100 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

Ginseneoside<br />

3<br />

1. Rg1<br />

2. Re<br />

3. Rb1<br />

10765<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 35 55 70 100<br />

%B: 19 19 29 29 40<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

nutraceuticals | vitamins<br />

Ginkgo Biloba<br />

Folium Ginkgo<br />

Terpene Lactones High Throughput<br />

10742<br />

10288<br />

2<br />

1<br />

3<br />

4<br />

1. Ginkgolide C<br />

2. Bilobalide<br />

3. Ginkgolide A<br />

4. Ginkgolide B<br />

1. Bilobalide<br />

2. Ginkgolide J<br />

3. Ginkgolide C<br />

4. Ginkgolide A<br />

5. Ginkgolide B<br />

1 2 3<br />

4 5<br />

0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 Min.<br />

0<br />

1 2 3 4 5 6 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:Tetrahydrofuran:Water (25:10:65)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column: Alltech ® Alltima C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 50605)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.1% Trifluoroacetic Acid in Methanol<br />

Gradient: Time: 0 5<br />

%B: 10 45<br />

Flow Rate: 5.0mL/min<br />

Detector: ELSD<br />

Ginkgo Biloba Flavonol Glycoside Standards<br />

Ginkgo Biloba Terpene Lactone Standards<br />

1<br />

4<br />

10239 10287<br />

2<br />

3<br />

1. Quercetin<br />

2. Kaempferol<br />

3. Isorhamnetin<br />

1<br />

23<br />

5<br />

1. Bilobalide<br />

2. Ginkgolide J<br />

3. Ginkgolide C<br />

4. Ginkgolide A<br />

5. Ginkgolide B<br />

0<br />

2 4 6 8 10 12 14 16 18 20 Min.<br />

Column: Alltech ® Platinum C18, 5µm, 250 x 4.6mm<br />

(Part No. 32064)<br />

Mobile Phase: A: 0.05% Trifluoroacetic Acid in Water:Methanol (95:5)<br />

B: 0.05% Trifluoroacetic Acid in Methanol<br />

Gradient: Time: 0 20<br />

%B: 10 90<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 100 x 4.6mm<br />

(Part No. 813812)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.1% Trifluoroacetic Acid in Methanol<br />

Gradient: Time: 0 15<br />

%B: 10 55<br />

Flow Rate: 1.3mL/min<br />

Detector: ELSD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

411


hplc applications<br />

nutraceuticals | vitamins<br />

1<br />

Liquid Ginkgo Biloba Extract Prep<br />

3<br />

2<br />

0 5 10 15 20 25 30 35 40 45 Min.<br />

4<br />

5<br />

1. Bilobalide<br />

2. Ginkgolide J<br />

3. Ginkgolide C<br />

4. Ginkgolide A<br />

5. Ginkgolide B<br />

10315<br />

Column: Alltech ® Alltima C18, 5µm, 150 x 10mm (Part No. 81102)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.1% Trifluoroacetic Acid in Methanol<br />

Gradient: Time: 0 45<br />

%B: 22 32<br />

Flow Rate: 5.0mL/min<br />

Detector: ELSD<br />

Flavonoids<br />

1<br />

Polyphenolic Flavonoids<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 26 Min.<br />

2<br />

3<br />

4<br />

5<br />

6<br />

1. Myricetin<br />

2. Quercetin<br />

3. Naringenin<br />

4. Hesperetin<br />

5. Apigenin<br />

6. Kaempferol<br />

9397<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208)<br />

Mobile Phase: A: 0.025M KH2PO4, pH2.5 B: Acetonitrile<br />

Gradient: Time: 0 15 25<br />

%B: 20 40 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 280<br />

1<br />

2<br />

3<br />

4<br />

Flavonoid Mix<br />

1. Myricetin<br />

2. Quercetin<br />

3. Apigenin<br />

4. Kaempferol<br />

Flavonoid Mix<br />

9271 8887<br />

2<br />

1. Naringin<br />

1<br />

2. Neohesperidin<br />

3. Myricetin<br />

4. Quercetin<br />

5. Naringenin<br />

6. Kaempferol<br />

3<br />

5 6<br />

4<br />

0 1 2<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

3 4 5 Min. 0 5<br />

10 15 Min.<br />

Alltech ® Alltima C18 3µm, 53 x 7mm Rocket<br />

(Part No. 50605)<br />

0.1% Trifluoroacetic Acid in Water:<br />

0.1% Trifluoroacetic Acid in Acetonitrile (65:35)<br />

2.5mL/min<br />

ELSD<br />

Column: Alltech ® Alltima C18, 3µm, 100 x 4.6mm (Part No. 81382)<br />

Mobile Phase: A: 0.05M K2HPO4, pH2.5 B: Acetonitrile<br />

Gradient: Time: 0 15<br />

%B: 20 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 280nm<br />

St. John’s Wort<br />

Echinacea<br />

1<br />

Hypericins<br />

1. Pseudohypericin<br />

2. Hypericin<br />

9107 9110<br />

3<br />

1<br />

Phenolic Acids<br />

1. Protocatechuic Acid<br />

2. Chlorogenic Acid<br />

3. Caffeic Acid<br />

2<br />

2<br />

0 1<br />

2<br />

3 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 50605)<br />

Mobile Phase: 0.2% Phosphoric Acid:Methanol (5:95)<br />

Flow Rate: 4.0mL/min<br />

Detector: Vis at 585nm<br />

0 1<br />

2 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 50605)<br />

Mobile Phase: 0.01M K2HPO4, pH2.6:Acetonitrile (80:20)<br />

Flow Rate: 3.5mL/min<br />

Detector: UV at 330nm<br />

412<br />

www.discoverysciences.com


hplc applications<br />

Chinese Pharmacopeia<br />

Fructus Liquidambaris<br />

Fructus Kochiae<br />

10743<br />

10744<br />

1. Liguidanbaric Acid 1. Momordin lc<br />

0 2 4 6 8 10 12 14 16 18 20 Min. 0 1 2 3 4 5 6 7 8 9 10 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810) Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:Water:Acetic Acid (87:13:0.1)<br />

Mobile Phase: Methanol:Water:Acetic Acid (85:15:0.2)<br />

Flow Rate: 1.0mL/min<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Detector: ELSD<br />

nutraceuticals | vitamins<br />

Bulbus Fritillariae Thunbergii<br />

10745<br />

Rhizoma Anemarrhenae<br />

10746<br />

1<br />

1. Peimine<br />

2. Peininine<br />

1. Sarsasapogenin<br />

2<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Acetonitrile:Water:Diethylamine (70:30:0.3)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 2 4 6 8 10 12 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:Water (95:5)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Radix Astragali<br />

10747<br />

1. Astragaloside IV<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm<br />

(Part No. 5138810)<br />

Mobile Phase: Acetonitrile:Water (35:65)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

413


hplc applications<br />

nutraceuticals | vitamins<br />

mAU<br />

Puerarin<br />

500<br />

400<br />

300<br />

200<br />

100<br />

0<br />

0 5 10 15 20 25 30 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

Puerarin<br />

1. Puerarin<br />

10773<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:0.1% Citric Acid (25:75)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 250nm<br />

mAU<br />

Tanshinone II<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

0<br />

5 10 15 20 25 30 35 40 45 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

Tanshinone II<br />

1. Tanshinone II<br />

10769<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:Water (75:25)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 270nm<br />

Green Tea<br />

Green Tea Extract - Analytical<br />

Green Tea Extract - Preparative<br />

10139<br />

10140<br />

3<br />

1. Caffeine<br />

2. Epicatechin<br />

3. Epigallocatechin Gallate<br />

1. Caffeine<br />

2. Epicatechin<br />

3. Epigallocatechin Gallate<br />

3<br />

1<br />

2<br />

1 2<br />

0 2<br />

4 6 8 10 12 14 16 18 20 Min.<br />

0 2<br />

4 6 8 10 12 14 16 18<br />

Column: Alltech ® Alltima C18, 5µm, 150 x 4.6mm (Part No. 88052)<br />

Mobile Phase: 0.05% Trifluoroacetic Acid:Acetonitrile (87:13)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column: Alltech ® Alltima C18, 5µm, 150 x 22mm (Part No. 81106)<br />

Mobile Phase: 0.05% Trifluoroacetic Acid:Acetonitrile (87:13)<br />

Flow Rate: 23mL/min<br />

Detector: ELSD<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

Catechins<br />

7 8<br />

8825<br />

1. Gallic Acid<br />

2. Epigallocatechin<br />

3. Catechin<br />

4. Epicatechin<br />

5. Epigallocatechin Gallate<br />

6. Caffeine<br />

7. Gallocatechin<br />

8. Epicatechin Gallate<br />

Catechins and Gallic Acid in Green Tea<br />

Catechins and Gallic Acid in Green Tea<br />

6<br />

1. Gallic 1. Acid Gallic Acid<br />

2. Gallocatechin 2. Gallocatechin<br />

1<br />

3. Epigallocatechin<br />

3. Epigallocatechin<br />

4. Catechin<br />

4. Catechin<br />

5. Epicatechin<br />

5. Epicatechin<br />

8 6. Epigallocatechin Gallate<br />

6. Epigallocatechin Gallate<br />

7. Gallocatechin Gallate<br />

7. Gallocatechin Gallate<br />

8. Epicatechin Gallate<br />

8. Epicatechin Gallate<br />

9. Catechin Gallate<br />

9. Catechin Gallate<br />

2 4 5 7 9<br />

3<br />

414<br />

0 1<br />

2<br />

www.discoverysciences.com<br />

3<br />

Column: Alltech ® Platinum EPS C18,<br />

1.5µm, 33 x 7mm Rocket (Part No. 50577)<br />

Mobile Phase: 0.05% Trifluoroacetic Acid:Acetonitrile (87:13)<br />

Flow Rate: 2.5mL/min<br />

Detector: UV at 210nm<br />

4<br />

5 Min. 0 2 4 6 8 10 12 14 16 18 20 22 Min.<br />

Column: Vydac ® Denali ® , 5µm, 150 x 4.6mm (Part No. 238DE5415)<br />

Mobile Column: Phase: DENALI A: Acetonitrile:25mM 238DE5415 (5 µm, 4.6 Phosphoric mm i.d. x 150 Acid mm) (10:90)<br />

Flow:<br />

1.0 B: mL/min Acetonitrile:25mM Phosphoric Acid (90:10)<br />

Eluent: A = 10:90 (v/v) ACN:25 mM phosphoric acid<br />

Gradient: Time: 0 3 22<br />

B = 90:10 (v/v) ACN:25 mM phosphoric acid<br />

B%: 0 0 15<br />

Gradient: Hold 100% A for 3 min, then 0 to 15% B over 19 min<br />

Flow Temp: Rate: 25 °C 1.0mL/min<br />

Detector: Detection: Absorbance, UV at 280nm<br />

nm<br />

Sample: 10 µL of green tea extract


hplc applications<br />

Vitamins<br />

1<br />

2 3<br />

5 6<br />

4<br />

7<br />

8<br />

9<br />

0 5 10 15 20 25 30 Min.<br />

1<br />

Water- and Fat-Soluble Vitamins<br />

2 3<br />

4<br />

5<br />

6<br />

7<br />

10<br />

12 14<br />

11 13 15<br />

9545<br />

1. Thiamine<br />

2. Ascorbic Acid<br />

3. Nicotinic Acid<br />

4. Niacinamide<br />

5. Pantothenic Acid<br />

6. Riboflavin<br />

7. Cyanocobalamin<br />

8. Biotin<br />

9. Vitamin A<br />

10. Δ-Tocopherol<br />

11. γ-Tocopherol<br />

12. α-Tocopherol<br />

13. Vitamin D2<br />

14. Vitamin D3<br />

15. Vitamin K<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208)<br />

Mobile Phase: A: Water pH3.2 w/Formic Acid<br />

B: Acetonitrile:Methanol (83:17)<br />

Gradient: Time: 0 3 10 10.1 30<br />

%B: 0 0 45 100 100<br />

Flow Rate: 1.5mL/min<br />

Detector: ELSD<br />

Fat-Soluble Vitamins and Tocopherols<br />

9390<br />

1. Vitamin A<br />

2. Δ-Tocopherol<br />

3. γ-Tocopherol<br />

4. α-Tocopherol (Vitamin E)<br />

5. Vitamin D2<br />

6. Vitamin D3<br />

7. Vitamin K<br />

1<br />

2<br />

3<br />

4<br />

Water-Soluble Vitamins<br />

1<br />

5<br />

2<br />

6<br />

7<br />

1. Ascorbic Acid<br />

2. Nicotinic Acid<br />

3. Pyridoxamine<br />

4. Niacinamide<br />

5. Folic Acid<br />

6. Vitamin B12<br />

7. Riboflavin<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 150 x 4.6mm (Part No. 5138812)<br />

Mobile Phase: A: 0.1M Ammonium Dihydrogen Orthophosphate<br />

Buffer, pH4.5<br />

B: Acetonitrile<br />

Gradient: Time: 0 4 10 15<br />

B%: 5 5 40 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Fat-Soluble Vitamins<br />

1. Vitamin A (100ng on column)<br />

2. Vitamin E (160ng on column)<br />

3. Vitamin K1 (130ng on column)<br />

3<br />

10733<br />

10279<br />

nutraceuticals | vitamins<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208)<br />

Mobile Phase: Acetonitrile:Methanol (75:25)<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 220nm<br />

0 1 2 3 4 5 6 7 8 9 10 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 150 x 1mm (Part No. 88384)<br />

Mobile Phase: Methanol:Chloroform (90:10)<br />

Flow Rate: 0.05mL/min<br />

Detector: ELSD<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

Water-Soluble Vitamins<br />

from Multi-Vitamin Tablet<br />

7<br />

1. Thiamine<br />

2. Ascorbic Acid<br />

3. Unknown<br />

4. Fumaric Acid<br />

5. Pyridoxine<br />

6. Niacinamide<br />

7. Pantothenic Acid<br />

9456<br />

1<br />

2<br />

3<br />

4<br />

Water-Soluble Vitamins<br />

5 6<br />

7<br />

1. Ascorbic Acid<br />

2. Nicotinic Acid<br />

3. Pyridoxamine<br />

4. Niacinamide<br />

5. Folic Acid<br />

6. Riboflavin<br />

7. Vitamin B12<br />

8154<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208)<br />

Mobile Phase: 0.025M KH2PO4, pH3.0:Acetonitrile (97:3)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 212<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column: Alltech ® Platinum C18, 5µm, 150 x 4.6mm<br />

(Part No. 32043)<br />

Mobile Phase: A: 0.1M Ammonium Phosphate, pH4.5<br />

B: Acetonitrile<br />

Gradient: Time: 0 4 15 18<br />

B%: 5 5 40 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

415


hplc applications<br />

1) a-Tocopherol<br />

2) b-Tocopherol<br />

3) g-Tocopherol<br />

4) d-Tocopherol<br />

nutraceuticals | vitamins<br />

Vitamins<br />

1<br />

2<br />

3<br />

4<br />

Analysis of Tocopherols<br />

1. a-Tocopherol<br />

2. b-Tocopherol<br />

3. g-Tocopherol<br />

4. d-Tocopherol<br />

Analysis of Tocopherols<br />

Column phase: GROM-SIL 120 Amino-2 PA,<br />

5 µm<br />

Column size: 250 x 4 mm<br />

Vitamin E<br />

Eluent: hexane / ethyl acetate =<br />

70 / 30<br />

4<br />

Flow rate: 0.8 ml/min<br />

2<br />

Pressure: 2 MPa<br />

Temperature: 30°C<br />

Detection (UV): 295 nm, 0.08 AUFS 1<br />

Injection: 7 µl (250 µg/ml, each)<br />

6<br />

3<br />

5<br />

7<br />

Vitamin E<br />

8<br />

1. a-Tocopherol<br />

2. a-Tocotrienol<br />

3. b-Tocopherol<br />

4. g-Tocopherol<br />

5. b-Tocotrienol<br />

6. g-Tocotrienol<br />

7. d-Tocotrienol<br />

8. d-Tocotrienol<br />

0 10 20 30 Min. 0 5 10 15 20 25 Min.<br />

Column: Grom Sil 120 Amino-2 PA, 5µm, 250 x 4mm<br />

Column: Jones Genesis ® Si, 3µm, 250 x 4.6mm<br />

(Part No. 5113466)<br />

Column: GENESIS FM25961E (Part No. FM25961E)<br />

(Si, 3 µm, 4.6 mm i.d. x 250 mm)<br />

Mobile Phase: Hexane:Ethyl Acetate (70:30)<br />

Flow: Mobile Phase: 1.5 mL/min Hexane:1,4-Dioxane (96:4)<br />

Flow Rate: 0.8mL/min<br />

Eluent: Flow Rate: Isocratic, 96:4 1.5mL/min Hexane/1,4-Dioxane<br />

Detector: UV at 295nm<br />

Detection: Detector: Fluorescence, Fluorescence (294 nm excitation, 294nm 326 (exc.), nm emission) 326nm (em.)<br />

Peaks: 1. a-tocopherol, 2. a-tocotrienol, 3. b-tocopherol,<br />

4. g-tocopherol, 5. b-tocotrienol, 6. g-tocotrienol,<br />

Vitamin E Soft Gel Tablet<br />

Determination of Retinol, a-Tocopherol,<br />

3<br />

Determination 7. d-tocotrienol, of Retinol, α-Tocopherol, 8. d-tocotrienoland β-Carotene in Serum<br />

2<br />

9458<br />

and b-Carotene in Serum<br />

1. Δ-Tocopherol<br />

2. γ-Tocopherol<br />

325 nm 295 nm 450 nm<br />

1. All-trans-Retinol<br />

3. α-Tocopherol<br />

7<br />

2. Tocol<br />

3. g-Tocopherol<br />

4. a-Tocopherol<br />

1<br />

5. Lutein<br />

4 6. Zeaxanthin<br />

5<br />

2<br />

9<br />

7. Cryptoxanthin<br />

1<br />

3 6 8<br />

8. a-Carotene<br />

10 9. All-trans-b-Carotene<br />

10. cis-b-Carotene<br />

0 3 6 9 12 15 Min.<br />

0 4 8 12 16 20 24 28 32 Min.<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208) Column:<br />

Column: VYDAC Vydac 201TP54 C4, (C18, 5µm, 5 µm, 2504.6 x 4.6mm mm i.d. (Part x 250 No. mm) 201TP54)<br />

Mobile Phase: Acetonitrile:Methanol (75:25)<br />

Mobile Flow: Phase: 1.5 mL/min A: Buffer:Methanol:n-Butanol (15:75:10)<br />

Flow Rate: 1.5mL/min<br />

Eluent: A = 15:75:10 B: Buffer:Methanol:n-Butanol buffer/methanol/n-butanol(2:88:10)<br />

Detector: ELSD<br />

B = 2:88:10 Buffer:Aqueous buffer/methanol/n-butanol<br />

0.02M Ammonium Acetate, pH3.5<br />

Gradient: buffer Time: = aqueous 00.023 M NH18 4 OAc, 32pH 3.5<br />

Gradient: 100% %B: A for 3 min, 0 then 0 0 to 100 100% 100B over 15 min,<br />

Figure 2. Rechromatography<br />

then hold 100%<br />

of<br />

B<br />

Flow Rate: 1.5mL/minβ-isomer-enriched tocopherol<br />

Detection: Absorbance, programmed wavelength<br />

from Figure Detector: 1. Shaded area Absorbance, indicates programmed collected wavelength fractions<br />

Figure 1. First step separation of tocopherol β-isomer on<br />

Davisil LC60Å 20-45mm Column. Shaded area indicates<br />

Preparative Purification Peaks: of Tocopheral<br />

1. All-trans-retinol (vitamin A), 2. Tocol, 3. g-Tocopherol, 4. a-Tocopherol (vitamin E), 5. L<br />

collected fraction<br />

7. Cryptoxanthin, 8. a-Carotene, 9. All-trans-b-carotene, 10. Cis-b-carotene<br />

First Step Separation of Tocopherol b-Isomer<br />

Rechromatography of b-Isomer-Enriched Tocopherol<br />

0 20 40 60 80 100 120 140 160 Min.<br />

Shaded area indicates collected fraction.<br />

Sample is 250g tocopherol isomer mixture in 1000mL hexane.<br />

Sample: 250g tocopherol isomer mixture in 1000ml hexane<br />

Silica:<br />

Column: 200 x<br />

Davisil<br />

500mm Davisil ® LC60Å ® LC60A<br />

20-45µm,<br />

20-45mm<br />

(Part No. 5055349)<br />

Column: Mobile Phase: hexane/2.5% 200 x THF 500mm<br />

Flow Rate: 600ml/min (115cm/hr)<br />

Mobile Phase: Hexane:2.5% Tetrahydrofuran<br />

Flow Rate: 600mL/min<br />

0 20 40 60 80 100 120 Min.<br />

Shaded area indicates collected fractions.<br />

Sample is pooled fraction from first step.<br />

Silica: Davisil ® LC60Å 20-45µm, (Part No. 5055349)<br />

Column: 50 x 500mm<br />

Flow Rate: 50mL/min<br />

Sample: Pooled fraction from run showed in Figure 1<br />

Column: 50 x 500mm Davisil LC60Å 20-45mm<br />

Flow Rate: 50ml/min (155cm/hr)<br />

416<br />

www.discoverysciences.com


hplc applications<br />

1<br />

2<br />

b–Carotenes<br />

3<br />

4 5<br />

0 5 10 15 20 Min.<br />

Column:<br />

Eluent:<br />

b–Carotenes<br />

a-carotene<br />

cis-a-carotene<br />

1. 2. cis-a-Caroteneb-carotene<br />

3. b-Carotene 13-cis-b-carotene<br />

4. 13-cis-b-Carotene<br />

5. 9-cis-b-Carotene<br />

9-cis-b-carotene<br />

VYDAC 201TP54 (C4, 5 µm, 4.6 mm i.d. x 250 mm)<br />

Isocratic, 94:6 MeOH/chloroform<br />

Column: Vydac ® C4, 5µm, 250 x 4.6mm (Part No. 201TP54)<br />

Mobile Phase: Methanol:Chloroform (94:6)<br />

mAU<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

0<br />

Coenzyme Q10<br />

1. Coenzyme Q10<br />

5 10 15 20 25 30 35 40 45 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10771<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: Methanol:Ethanol (50:50)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 275nm<br />

nutraceuticals | vitamins<br />

Devil’s Claw<br />

1<br />

Iridoid Compounds<br />

0 1 2 3 4 5 6 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 50605)<br />

Mobile Phase: 0.05% Trifluoroacetic Acid:Methanol:Dioxane (75:23:2)<br />

Flow Rate: 3.0mL/min<br />

Detector: UV at 285nm<br />

2<br />

9191<br />

1. 8-para-Coumaroyl Harpagoside<br />

2. Harpagoside<br />

Saponins<br />

HPLC Analysis of Saikosides<br />

1) Saikosaponin c<br />

2) Saikosaponin f<br />

3) Saikosaponin a<br />

4) Saikosaponin b2<br />

5) Saikosaponin b1<br />

6) Saikosaponin d<br />

3<br />

HPLC Analysis of Saikosides<br />

1. Saikosaponin c<br />

2. Saikosaponin f<br />

3. Saikosaponin a<br />

4. Saikosaponin Column b2 phase: GROM-SIL 120 O<br />

1<br />

5. Saikosaponin Column b1 size: 250 x 4 mm<br />

6. Saikosaponin d<br />

Eluent: H2O / MeOH / ACN = 45 /<br />

4<br />

Flow rate: 0.8 ml/min<br />

2<br />

6<br />

Pressure: 8 MPa<br />

5<br />

Temperature: 40°C<br />

Detection (UV): 210 nm<br />

Injection: 5 µl (~30 µg of each)<br />

0 4 8 12 16 20 24 28 Min.<br />

Column: Grom Sil 120 ODS-3 CP, 5μm, 250 x 4mm<br />

Mobile Phase: Water:Methanol:Acetonitrile (45:15:40)<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 210nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

417


hplc applications<br />

Goldenseal Root<br />

1<br />

Alkaloids<br />

2<br />

9124<br />

Black Cohosh<br />

Black Cohosh Extract<br />

9496<br />

nutraceuticals | vitamins<br />

0 1<br />

1. Hydrastine<br />

2. Berberine<br />

2 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 50605)<br />

Mobile Phase: 0.02M KH2PO4, pH2.6:Methanol (52:48)<br />

Flow Rate: 3.0mL/min<br />

Detector: UV at 235nm<br />

1<br />

2<br />

3<br />

1. Cimiracemoside A<br />

2. Actein<br />

3. 27-deoxyactein<br />

0 10 20 30 40 50 60 Min.<br />

Column: Alltech ® Prevail C18, 5µm, 250 x 4.6mm (Part No. 99210)<br />

Mobile Phase: A: 1% Formic Acid B: Acetonitrile<br />

Gradient: Time: 0 60 65 67 80<br />

%B: 20 100 100 20 20<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Glucosamine<br />

Glucosamine<br />

Evening Primrose<br />

Triglycerides<br />

1<br />

1<br />

1<br />

UV<br />

ELSD<br />

RI<br />

1. Glucosamine<br />

10412<br />

10413<br />

10411<br />

1<br />

2<br />

3<br />

4 5 6 7<br />

8<br />

1. LGG<br />

2. LGL<br />

3. LLL<br />

4. OGL<br />

5. PGL<br />

6. OLL<br />

7. OGO + PLL<br />

8. OOO<br />

10047<br />

0 1 2 3 4 5 Min.<br />

0 10 20 30 40 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 150 x 4.6mm<br />

(Part No. 35102)<br />

Mobile Phase: Acetonitrile:Water (65:35)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column: Alltech ® Alltima C18, 5µm, 250 x 4.6mm (Part No. 88056)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 40<br />

%B: 30 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

418<br />

www.discoverysciences.com


hplc applications<br />

Carbohydrates<br />

1<br />

Corn Syrup Oligomers<br />

2<br />

3<br />

4 5 6<br />

7 8<br />

1. Dextrose<br />

2. Maltose<br />

3. Maltotriose<br />

4. Maltotetraose<br />

5. Maltopentaose<br />

6. Maltohexaose<br />

7. Maltoheptaose<br />

8. Maltooctaose<br />

0 1 2 3 4 5 6 7 8 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES,<br />

5µm, 53 x 7mm Rocket (Part No. 35104)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 4<br />

%B: 32 50<br />

Flow Rate: 2.0mL/min<br />

Detector: ELSD<br />

9420<br />

1<br />

2<br />

3<br />

Corn Syrup Solids<br />

1. Dextrose<br />

2. Maltose<br />

3. Maltotriose<br />

4. Maltotetraose<br />

5. Maltopentaose<br />

4 5<br />

6<br />

13<br />

7<br />

8<br />

101112<br />

9<br />

9354<br />

6. Maltohexaose<br />

7. Maltoheptaose<br />

8. Maltooctaose<br />

9. Maltononaose<br />

10. Maltodecaose<br />

11. Maltoundecaose<br />

12. Maltododecaose<br />

13. Maltotridecaose<br />

0 5 10 15 20 25 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 15<br />

%B: 35 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

food & beverage<br />

Mono-, Di-, Tri- Saccharides<br />

14<br />

15<br />

11<br />

2<br />

7<br />

12<br />

3<br />

9 10 13<br />

4 1618<br />

5 6<br />

1 8<br />

17 19<br />

20<br />

21<br />

22<br />

1. iso-Erythritol<br />

2. Fructose<br />

3. Sorbitol<br />

4. Mannitol<br />

5. Glucose<br />

6. Inositol<br />

7. Sucrose<br />

8. Maltitol<br />

9. Maltose<br />

10009<br />

10. Raffinose<br />

11. DP3<br />

12. DP4<br />

13. DP5<br />

14. DP6<br />

15. DP7<br />

16. DP8<br />

17. DP9<br />

18. DP10<br />

19. DP11<br />

20. DP12<br />

21. DP13<br />

22. DP14<br />

1<br />

2<br />

Sugars<br />

1. Fructose<br />

2. Glucose<br />

3. Sucrose<br />

3<br />

10277<br />

0 10 20 30 40 50 60 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm,<br />

250 x 4.6mm (Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: 0.04% Ammonium Hydroxide in Water<br />

Gradient: Time: 0 25 40 60<br />

%B: 17 27 45 55<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

1 2 3<br />

Beer Standards<br />

Unmodified Mobile Phase<br />

4<br />

5 6<br />

7<br />

1. Fructose<br />

2. Glucose<br />

3. Sucrose<br />

4. Maltose<br />

5. Maltotriose<br />

6. Maltotetraose<br />

7. Maltopentaose<br />

0 1 2 3 4 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES,<br />

5µm, 53 x 7mm Rocket (Part No. 35104)<br />

Mobile Phase: Acetonitrile:Water (75:25)<br />

Flow Rate: 2.0mL/min<br />

Column Temp: 30°C<br />

Detector: ELSD<br />

Beer Standards<br />

1 Modified Mobile Phase<br />

9350 2<br />

9360<br />

1. Fructose<br />

2. Glucose<br />

3<br />

3. Sucrose<br />

4. Maltose<br />

4<br />

5. Maltotriose<br />

5 6 7<br />

6. Maltotetraose<br />

7. Maltopentaose<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 50<br />

%B: 20 35<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 2<br />

4<br />

6<br />

8 10 12 14 16 18 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile:Acetone (75:25)<br />

B: Water<br />

Gradient: Time: 0 18<br />

%B: 24 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

419


hplc applications<br />

food & beverage<br />

Carbohydrates<br />

1 2<br />

Sugar Alcohols<br />

3 4<br />

1. iso-Erythritol<br />

2. Xylitol<br />

3. Mannitol<br />

4. Maltitol<br />

9352<br />

0 5 10 15 20 25 30 35 40 45 Min.<br />

0 2 4 6 8 10 12 Min.<br />

4<br />

5 6 4<br />

7<br />

1 2<br />

Column: Alltech ® Prevail Carbohydrate ES, 250 x 4.6mm<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

(Part No. 35101)<br />

Mobile Phase: Acetonitrile:Water (70:30)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Flow Rate: 1.0mL/min<br />

Gradient: Time: 0 60<br />

Detector: ELSD<br />

%B: 17 35<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Imported Ale<br />

Beverage Additives<br />

3<br />

9351<br />

5<br />

9446<br />

1. Fructose<br />

1. Ascorbic Acid<br />

2. Glucose<br />

2. Saccharin<br />

3. Maltose<br />

2<br />

3. Benzoic Acid<br />

4. Maltotriose<br />

3<br />

4. Aspartame<br />

5. Maltopentaose<br />

5. Vanillin<br />

6. Maltohexaose<br />

7. Maltoheptaose<br />

1<br />

1<br />

Wine Analysis - 2000 Sipaska Rosé<br />

2 3 4<br />

1. Fructose<br />

2. Sorbitol<br />

3. Glucose<br />

4. Maltose<br />

9474<br />

0 5 10 15 20 25 30 35 40 45 50 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 50<br />

%B: 20 35<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 1 2 3 Min.<br />

Column: Alltech ® Prevail C18, 3µm, 50 x 2.1mm (Part No. 43818)<br />

Mobile Phase: Acetonitrile:0.05M Ammonium Acetate, pH5.4, (20:80)<br />

Flow Rate: 0.3mL/min<br />

Detector: UV at 230<br />

Wine Analysis by Ion Exclusion<br />

5411<br />

Partial Digest: Complex Polysaccharide<br />

from Plant Cell Wall<br />

0<br />

3 5<br />

2<br />

1<br />

4<br />

6<br />

7<br />

10<br />

8 9<br />

10 20 30 40 50 Min.<br />

1. Citric Acid<br />

2. Tartaric Acid<br />

3. Glucose<br />

4. Malic Acid<br />

5. Fructose<br />

6. Acetic Acid<br />

7. Glycerol<br />

8. Lactic Acid<br />

9. Methanol<br />

10. Ethanol<br />

Column: Alltech ® IOA-1000, 9mm, 300 x 7.8mm (Part No. 9646)<br />

Mobile Phase: 0.005N Sulfuric Acid<br />

Flow Rate: 0.3mL/min<br />

Column Temp: 60°C<br />

Detector: RI<br />

Partial Digest: Complex Polysaccharide from Plant Cell Wall<br />

0 15 30 45 60 75 90 Min.<br />

Columns: VYDAC 218TP54 C18, 5 µm, 4.6 mm i.d. x 250mm<br />

Flow: Column: 1.0 mL/min Vydac ® C18, 5µm, 250 x 4.6mm (Part No. 218TP54)<br />

Gradient: Linear, 7 7 to to 10% Methanol MeOH over over 60 min., 60 min., then to 25%<br />

MeOH then at 90 to min 25% Methanol at 90 min<br />

Detection: Flow Rate: Evaporative 1.0mL/min light-scattering detection (ELSD)<br />

Detector: ELSD<br />

420<br />

www.discoverysciences.com


hplc applications<br />

3<br />

1<br />

2 4<br />

Conquistador ® Tequila<br />

0 2 4 6 8 10 12 14 16 18 Min.<br />

5<br />

1. Fructose<br />

2. Mannitol<br />

3. Glucose<br />

4. Sucrose<br />

5. Unknown<br />

10585<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: Acetonitrile:Water (75:25)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

1<br />

2<br />

3 4<br />

Splenda ® Sweetener<br />

0 5 10 15 20 25 30 35 40 Min.<br />

1. Sucralose<br />

2. Glucose<br />

3. Maltose<br />

4. Maltodextrins<br />

10531<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 20 20 30 30 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

food & beverage<br />

1<br />

2<br />

3<br />

4<br />

6<br />

5<br />

7<br />

Pepsi One ® Cola<br />

8<br />

1. Sucralose<br />

2. Unknown 1<br />

3. Fructose<br />

4. Glucose<br />

5. Unknown 2<br />

6. Sucrose<br />

7. Maltose<br />

8. Maltodextrins<br />

10530<br />

1<br />

2<br />

Infant Formula<br />

1. Sucrose<br />

2. Lactose<br />

10529<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 20 20 30 30 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 20 20 30 30 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Flavor Sample Solution<br />

Chromatogram courtesy of Charles Stewart, Firmenich Inc.<br />

10579<br />

Spiked Urine<br />

Chromatogram courtesy of Rosemary Rose,<br />

Monash University, Dept. of Gastroenterology<br />

10584<br />

1<br />

2<br />

3<br />

1. Fructose<br />

2. Glucose<br />

3. Sucrose<br />

1<br />

2 3<br />

1. Sucralose<br />

2. Rhamnose<br />

3. Cellobiose<br />

0 5 10 15 20 25 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 30<br />

%B: 20 29<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 150 x 4.6mm<br />

(Part No. 35102)<br />

Mobile Phase: Acetonitrile:Water (70:30)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

421


hplc applications<br />

Carbohydrates<br />

Robitussin ® Flu Syrup<br />

10557<br />

Cough Syrup<br />

10556<br />

food & beverage<br />

1<br />

2<br />

3<br />

4<br />

5 6<br />

0 5 10 15 20 25 30 35 40 Min.<br />

1. Sucralose<br />

2. Fructose<br />

3. Sorbitol<br />

4. Glucose<br />

5. Sucrose<br />

6. Maltose<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 15 15 25 25 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

1<br />

2<br />

3<br />

4<br />

0 5 10 15 20 25 30 35 40 Min.<br />

1. Fructose<br />

2. Glucose<br />

3. Sucrose<br />

4. Maltose<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 20 20 30 30 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

1<br />

2<br />

3<br />

Tobacco<br />

0 5 10 15 20 25 30 35 40 Min.<br />

4<br />

1. Fructose<br />

2. Glucose<br />

3. Sucrose<br />

4. Unknown<br />

10526<br />

1<br />

2<br />

3<br />

Kellogg's Frosted Flakes ® Cereal<br />

Regular vs. 1/3 less sugar<br />

4 5<br />

1 2 4<br />

5<br />

0 5 10 15 20 25 30 35 40 Min.<br />

3<br />

Regular<br />

1. Fructose 10527<br />

2. Glucose<br />

3. Sucrose<br />

4. Maltose<br />

5. Oligosaccharides<br />

1/3 Less Sugar<br />

10528<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 20 20 30 30 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column: Alltech ® Prevail Carbohydrate ES, 5µm, 250 x 4.6mm<br />

(Part No. 35101)<br />

Mobile Phase: A: Acetonitrile B: Water<br />

Gradient: Time: 0 5 10 15 25<br />

%B: 20 20 30 30 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Rosenta Analysis<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Grom Sil 100 ODS-2 FE, 5μm, 250 x 4mm<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 30<br />

%B: 25 100<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 254nm<br />

422<br />

www.discoverysciences.com


hplc applications<br />

Organic Acids<br />

1<br />

8<br />

2<br />

4 6 7<br />

3 5<br />

9 10<br />

11<br />

0 1 2 3 4 5 6 7 8 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Organic Acid Mix<br />

1. Oxalic Acid<br />

2. Tartaric Acid<br />

3. Formic Acid<br />

4. Malic Acid<br />

5. Lactic Acid<br />

6. Acetic Acid<br />

7. Diglycolic Acid<br />

8. Maleic Acid<br />

9. Citric Acid<br />

10. Succinic Acid<br />

11. Fumaric Acid<br />

Alltech ® Prevail Organic Acid, 5µm, 150 x 4.6mm<br />

(Part No. 88640)<br />

0.025M KH2PO4, pH2.5<br />

1.5mL/min<br />

UV at 210nm<br />

9384<br />

1<br />

2<br />

3<br />

4<br />

0 2 4 6 8 10 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Rye Bread Extract<br />

5<br />

1. Tartaric Acid<br />

2. Malic Acid<br />

3. Lactic Acid<br />

4. Citric Acid<br />

5. Fumaric Acid<br />

Alltech ® Prevail Organic Acid, 5µm, 150 x 4.6mm<br />

(Part No. 88640)<br />

0.025M KH2PO4, pH2.5<br />

1.0mL/min<br />

UV at 210nm<br />

9484<br />

food & beverage<br />

1<br />

2<br />

3<br />

4<br />

Underivatized Fatty Acids<br />

5<br />

6<br />

1. Lauric Acid<br />

2. Myristic Acid<br />

3. Palmitic Acid<br />

4. Stearic Acid<br />

5. Arachidic Acid<br />

6. Behenic Acid<br />

9539<br />

5<br />

3<br />

1<br />

2 4 6<br />

7<br />

Organic Acid Mix<br />

8244<br />

1. Tartaric Acid<br />

2. Malic Acid<br />

3. Lactic Acid<br />

4. Diglycolic Acid<br />

5. Maleic Acid<br />

6. Succinic Acid<br />

7. Fumaric Acid<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

Column: Alltech ® Prevail Organic Acid, 5µm, 150 x 4.6mm<br />

(Part No. 88640)<br />

Mobile Phase: Acetonitrile:Methanol (75:25)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

3<br />

2<br />

4<br />

6<br />

1<br />

5<br />

8<br />

7<br />

Short-Chain Aromatic Carboxylic Acids<br />

9<br />

10<br />

11<br />

12<br />

7067<br />

1. Oxalic Acid<br />

2. Citric Acid<br />

3. Shikimic Acid<br />

4. Fumaric Acid<br />

5. Butyric Acid<br />

6. Homoprotocatechuic Acid<br />

7. Gallic Acid<br />

8. Protocatechuic Acid<br />

9. Gentisic Acid<br />

10. p-Hydroxybenzoic Acid<br />

11. Benzoic Acid<br />

12. Salicylic Acid<br />

0 10 20 30 Min.<br />

Column: Alltech ® OA-2000, 6.5µm, 100 x 6.5mm (Part No. 9048)<br />

Mobile Phase: 0.01N Sulfuric Acid<br />

Column Temp: 45°C<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 228nm<br />

0 2 4 6 8 10 Min.<br />

Column: Alltech ® Platinum EPS C8, 5µm, 150 x 4.6mm<br />

(Part No. 32420)<br />

Mobile Phase: 0.025M KH2PO4, pH2.5:Methanol (97:3)<br />

Flow Rate: 0.7mL/min<br />

Detector: UV at 220nm<br />

0<br />

1 Fatty Acids Using UV and ELSD in Tandem<br />

4<br />

1. Caproic Acid<br />

2<br />

2. Caprylic Acid<br />

3. Capric Acid<br />

5<br />

4. Lauric Acid<br />

3<br />

5. Linolenic Acid<br />

6<br />

3<br />

6. Myristic Acid<br />

4 7 7<br />

5 6 8<br />

8 9 10<br />

UV<br />

9<br />

10<br />

ELSD<br />

2 4 6 8 10 12 14 16 18 Min.<br />

7. Linoleic Acid<br />

8. Palmitic Acid<br />

9. Oleic Acid<br />

10. Stearic Acid<br />

10430<br />

Column: Alltech ® Alltima HP C18 HiLoad, 3µm, 150 x 4.6mm<br />

(Part No. 87686)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.1% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 10 20<br />

%B: 80 100 100<br />

Flow Rate: 1.0mL/min<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

423


hplc applications<br />

Organic Acids<br />

Organic Acids<br />

10705<br />

3<br />

4<br />

Long Chain Fatty Acids<br />

9459<br />

food & beverage<br />

1<br />

2 3<br />

0 1 2 3 4 5 6 7 Min.<br />

4<br />

5<br />

1. Tartaric Acid<br />

2. Malic Acid<br />

3. Lactic Acid<br />

4.Maleic Acid<br />

5. Fumaric Acid<br />

1<br />

2<br />

5<br />

0 1 2 3 4 Min.<br />

1. Capric Acid<br />

2. Lauric Acid<br />

3. Myristic Acid<br />

4. Palmitic Acid<br />

5. Stearic Acid<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: 0.025M KH2PO4, pH2.5:Methanol (97:3)<br />

Flow Rate: 0.7mL/min<br />

Detector: UV at 220<br />

Iso-a-Acids in Beer<br />

Iso-a-Acids in Beer<br />

Column: Alltech ® Prevail C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 99279)<br />

Mobile Phase: Acetonitrile:Methanol (75:25)<br />

Flow Rate: 3.5mL/min<br />

Detector: ELSD<br />

Oils / Lipids<br />

6<br />

Olive Oil<br />

9515<br />

1 2<br />

3<br />

4 5 6 7<br />

1. Iso-a-Acid<br />

2. Iso-a-Acid 2<br />

3. Iso-a-Acid 3<br />

4. Tetra-hydro iso-a-Acid 1<br />

5. Tetra-hydro iso-a-Acid 2<br />

6. Tetra-hydro iso-a-Acid 3<br />

7. Tetra-hydro iso-a-Acid 4<br />

1 2<br />

3<br />

4<br />

5<br />

7<br />

1. LLO<br />

2. LLP<br />

3. OOL<br />

4. POL<br />

5. PPL<br />

6. OOO<br />

7. OOP<br />

8. PPO<br />

9. OOS<br />

0 5 10 15 20 25 Min.<br />

Column: Jones Genesis ® C18, 4µm, 150 x 4.6mm + 10mm guard<br />

(Part No. FM15960E + FH1960-2)<br />

Column: GENESIS FM15960E + FH1960-2<br />

Mobile Phase: (C18, 4 Methanol: µm, 4.6 mm 0.1% i.d. Phosphoric x 150 mm + 10 Acid, mm 0.5mM guard) EDTA (76:24)<br />

Flow: Flow Rate: 1.0 mL/min 1.0mL/min<br />

Eluent: Detector: Isocratic, UV 76% at 260nm methanol in<br />

0.1% phosphoric acid, 0.5 mM EDTA<br />

Detection: Absorbance, 260 nm<br />

Peaks: 1. Iso-a-acid 1, 2. Iso-a-acid 2, 3. Iso-a-acid 3,<br />

4. Tetra-hydro iso-a-acid Olive 1, 5. Oil Tetra-hydro iso-a-acid 2,<br />

6. Tetra-hydro iso-a-acid 3, 7. Tetra-hydro iso-a-acid 4<br />

8 9<br />

10561<br />

14<br />

1. LLO<br />

2. OOLn<br />

3. PLnO<br />

4<br />

4. LOO<br />

11<br />

5. PoOO<br />

6. PLO<br />

7. PoOP<br />

8. OOO<br />

9. POO+SOL<br />

10. POP<br />

5 10<br />

11. SOO<br />

6<br />

7 12<br />

1 2 12. POS+SLS<br />

3<br />

13. PPS<br />

13<br />

14. C17<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 150 x 4.6mm<br />

(Part No. 81387)<br />

Mobile Phase: A: Dichloromethane B: Acetonitrile<br />

Gradient: Time: 0 10 18 20<br />

%B: 70 55 70 70<br />

Flow Rate: 1.5mL/min<br />

Detector: ELSD<br />

Acid Whey<br />

3<br />

1. LACCER<br />

2. PA<br />

3. PE<br />

4. PI<br />

5. PS<br />

6. PC<br />

4<br />

5<br />

7. SM1<br />

2<br />

8. SM2<br />

6<br />

8 9<br />

1<br />

7<br />

8<br />

10576<br />

0 5 10 15 20 25 30 Min.<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm, 150 x 3.0mm<br />

(Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

0 5 10 15 20 Min.<br />

Column: Alltech ® Prevail Silica, 3µm, 150 x 3.0mm (Part No. 99341)<br />

Mobile Phase: A: Chloroform; B: Methanol; C: Triethylamine buffer pH3<br />

Gradient: Time: 0 16 17<br />

%B: 12 60 12<br />

%C: 0.5 12 0.5<br />

Flow Rate: 0.5mL/min<br />

Detector: ELSD<br />

424<br />

www.discoverysciences.com


hplc applications<br />

Oils / Lipids<br />

2<br />

Sesame Seed Oil<br />

9517<br />

Sesame Seed Oil<br />

10581<br />

1<br />

3<br />

0 2 4 6 8 10 12 14 16 Min.<br />

1<br />

2<br />

3<br />

4<br />

5 7<br />

6<br />

8<br />

Column: Alltech ® Alltima C18, 3µm, 150 x 4.6mm (Part No. 81387)<br />

Mobile Phase: A: Dichloromethane B: Acetonitrile<br />

Gradient: Time: 0 10 18 20<br />

%B: 70 55 70 70<br />

Flow Rate: 1.5mL/min<br />

Detector: ELSD<br />

4 5 6 7<br />

8<br />

1. LLL<br />

2. LLO<br />

3. LLP<br />

4. OOL<br />

5. POL<br />

6. PPL<br />

7. OOO<br />

8. OOP<br />

9. PPO<br />

10. OOS<br />

Evening Primrose Oil<br />

1. LGG<br />

2. LGL<br />

3. LLL<br />

4. OGL<br />

5. PGL<br />

6. OLL<br />

7. OGO + PLL<br />

8. OOO<br />

10047<br />

0 5 10 15 20 25 30 35 Min.<br />

1<br />

4<br />

1<br />

5 6<br />

2<br />

3<br />

4<br />

5 7 8<br />

9<br />

6<br />

10<br />

1. LLL<br />

2. LLO<br />

3. LLP<br />

4. OOL<br />

5. POL<br />

6. PPL<br />

7. OOO<br />

8. OOP<br />

9. PPO<br />

10. OOS<br />

Column: Alltima HP C18 Hi-Load, 5µm, 250 x 4.6mm<br />

(Part No. 87698)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Walnut Oil<br />

2<br />

1. Trilaurin (LaLaLa)<br />

9522<br />

2. Trilinolein (LLL)<br />

3. 1,2-Dilinoleyl-3-oleyl-rac-glycerol (LLO)<br />

4. 1,2-Dilinoleyl-3-palmitin-rac-glycerol (LLP)<br />

5. 1-Palmitin-2-olein-3-Linolein rac-glycerol (POL)<br />

3<br />

6. 1,2-Dipalmytyl-3-linolein-rac glycerol (PPL)<br />

food & beverage<br />

9 10 0 2 4 6 8 10 12 14 16 Min.<br />

0 10 20 30 40 Min.<br />

Column: Alltech ® Alltima C18, 5µm, 250 x 4.6mm (Part No. 88056)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 40<br />

%B: 30 50<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

1<br />

3<br />

4<br />

5 6 7<br />

Corn Oil<br />

14<br />

1. C11<br />

2. LLLn<br />

3. LLL<br />

4. LLO<br />

5. PLL<br />

6. LOO<br />

7. PLO<br />

10566<br />

8. PLP<br />

9. OOO<br />

10. SLO<br />

11. POO<br />

12. POP<br />

13. SOO/PPP<br />

14 C17<br />

Column: Alltech ® Alltima C18, 3µm, 150 x 4.6mm (Part No. 81387)<br />

Mobile Phase: A: Dichloromethane B: Acetonitrile<br />

Gradient: Time: 0 10 18 20<br />

%B: 70 55 70 70<br />

Flow Rate: 1.5mL/min<br />

Detector: ELSD<br />

Lecithin, 0.5mg/mL<br />

5<br />

2<br />

10562<br />

1. PA<br />

2. PE<br />

3. PI<br />

4. LPE<br />

5. PC<br />

6. LPC<br />

3<br />

2<br />

9 1011 12<br />

8<br />

13<br />

1<br />

4<br />

6<br />

0 5 10 15 20 25 30 35 Min.<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm, 150 x 3.0mm<br />

(Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

0 5<br />

Column:<br />

10 15 20 Min.<br />

Alltech ® Prevail Silica, 3µm, 150 x 3.0mm<br />

(Part No. 99341)<br />

Mobile Phase: A: Chloroform<br />

B: Methanol<br />

C: Triethylamine buffer pH3<br />

Gradient: Time: 0 16 17<br />

%B: 12 60 12<br />

%C: 0.5 12 0.5<br />

Flow Rate: 0.5mL/min<br />

Detector: ELSD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

425


hplc applications<br />

food & beverage<br />

Oils / Lipids<br />

5 Palm Kernel Olein Fraction<br />

2<br />

1<br />

7<br />

3 4<br />

89 10 11 12 17<br />

14 15 16<br />

6<br />

13<br />

0 5 10 15 20 25 30 Min.<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm,<br />

150 x 3.0mm (Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

Coconut Oil<br />

2<br />

1<br />

4 5 3<br />

6<br />

7<br />

9<br />

8 10 11 12<br />

0 5 10 15 20 25 30 35 Min.<br />

1<br />

2<br />

3<br />

4<br />

5 6 7 8 9<br />

13<br />

1. CCLa<br />

2. C11<br />

3. CLaLa<br />

4. CCM<br />

5. LaLaLa<br />

6. CLaM<br />

7. LaLaM<br />

8. LaLaO<br />

9. LaMM<br />

1. CCLa<br />

2. C11<br />

3. CLaLa<br />

4. CCM<br />

5. LaLaLa<br />

6. CLaM<br />

10573<br />

10. LaMO<br />

11. LaMP/MMM<br />

12. MMO/LaPO<br />

13. MMP/LaPP/MPO<br />

14. PLP<br />

15. POO<br />

16. POP<br />

17. C17<br />

10564<br />

7. LaLaM<br />

8. LaLaO<br />

9. LaMM<br />

10. LaMO<br />

11. LaMP/MMM<br />

12. MMP/LaPP/MPO<br />

13. C17<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm, 150 x 3.0mm<br />

(Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

Sunflower Oil<br />

1. LLL<br />

2. LLO<br />

3. PLL<br />

4. LOO<br />

5. LLS<br />

6. PLO<br />

7. OOO<br />

8. SLO<br />

9. POO<br />

10567<br />

0 5 10 15 20 25 30 Min.<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm,<br />

150 x 3.0mm (Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

Cocoa Butter<br />

9<br />

0 5 10 15 20 25 30 35 Min.<br />

1<br />

1<br />

2<br />

3<br />

6<br />

23 4 5 7 8<br />

Butter<br />

11<br />

13<br />

10 12<br />

4 5 67<br />

8 9 10<br />

11<br />

14<br />

1. C13<br />

2. PLO<br />

3. PLP<br />

4. POO<br />

5. PLS<br />

6. POP<br />

7. SOO/PPP<br />

8. SLS<br />

9. POS<br />

10. PPS<br />

11. SOS<br />

12. PSS<br />

13. SOA<br />

14. C19<br />

10563<br />

10565<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm, 150 x 3.0mm<br />

(Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

Refined Sunflower Oil<br />

1. C11<br />

2. LLL<br />

3. LLO<br />

4. PLL<br />

5. LOO<br />

6. LLS<br />

7. PLO<br />

8. OOO<br />

9. SLO<br />

10. POO<br />

11. C17<br />

10569<br />

0 5 10 15 20 25 30 35 Min.<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm,<br />

150 x 3.0mm (Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

0 5 10 15 20 25 30 Min.<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm,<br />

150 x 3.0mm (Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

426<br />

www.discoverysciences.com


hplc applications<br />

Oils / Lipids<br />

1<br />

23 4<br />

Palm Oil<br />

11<br />

10<br />

9<br />

5 678<br />

12<br />

13<br />

1415<br />

0 5 10 15 20 25 30 35 Min.<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm,<br />

150 x 3.0mm (Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10 1112<br />

15<br />

16<br />

14 17<br />

13 18<br />

0 5 10 15 20 25 30 35 Min.<br />

Column: Alltech ® Alltima HP C18 Hi-Load, 3µm, 150 x 3.0mm<br />

(Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

1<br />

2<br />

19<br />

16<br />

Polar Lipid Standards<br />

6<br />

3<br />

4<br />

Soybean Oil<br />

5<br />

7<br />

8<br />

1. C13<br />

2. OLL<br />

3. PLL<br />

4. LOO<br />

5. PLO<br />

6. PLP<br />

7. MOP<br />

8. OOO<br />

1. C11<br />

2. LLnLn<br />

3. LLLn<br />

4. LLL<br />

5. OLnL<br />

6. PLLn<br />

7. LLO<br />

8. OOLn<br />

9. PLL<br />

10. LOO<br />

1. GLUCCER<br />

2. LACCER<br />

3. PE<br />

4. PI<br />

5. PS<br />

6. PC<br />

7. SM1<br />

8. SM2<br />

10571<br />

9. POO<br />

10. PLS<br />

11. POP<br />

12. SOO/PPP<br />

13. POS<br />

14. PPS<br />

15. SOS<br />

16. C19<br />

10570<br />

11. LLS<br />

12. PLO<br />

13. PLP<br />

14. OOO<br />

15. SLO<br />

16. POO<br />

17. POP<br />

18. SOO/PPP<br />

19. C17<br />

10575<br />

0 5 10 15 20 Min.<br />

Column: Alltech ® Prevail Silica, 3µm, 150 x 3.0mm (Part No. 99341)<br />

Mobile Phase: A: Chloroform B: Methanol C: Triethylamine buffer pH3<br />

Gradient: Time: 0 16 17<br />

%B: 12 60 12<br />

%C: 0.5 12 0.5<br />

Flow Rate: 0.5mL/min<br />

Detector: ELSD<br />

2<br />

1 3 4<br />

5<br />

6<br />

7<br />

8<br />

10<br />

9 11 12<br />

0 5 10 15 20 25 30 Min.<br />

Column: A Alltech ® lltima HP C18 Hi-Load, 3µm,<br />

150 x 3.0mm (Part No. 87610)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 25 26 27 28<br />

%B: 30 51 70 70 30<br />

Flow Rate: 0.72mL/min<br />

Detector: ELSD<br />

1<br />

2<br />

3<br />

4<br />

5<br />

13<br />

0 5 10 15 20 Min.<br />

Column: Alltech ® Prevail Silica, 3µm, 150 x 3.0mm (Part No. 99341)<br />

Mobile Phase: A: Chloroform B: Methanol; C: Triethylamine buffer pH3<br />

Gradient: Time: 0 16 17<br />

%B: 12 60 12<br />

%C: 0.5 12 0.5<br />

Flow Rate: 0.5mL/min<br />

Detector: ELSD<br />

1<br />

Palm Kernel Stearin Fraction<br />

2<br />

3<br />

4<br />

5<br />

6<br />

Butter<br />

6<br />

7 8<br />

9 10<br />

1. CCLa<br />

2. C11<br />

3. CLaLa<br />

4. CMM<br />

5. LaLaLa<br />

6. LaLaM<br />

7. LaLaO<br />

Gouda Cheese<br />

10572<br />

8. LaMM<br />

9. LaMO<br />

10. LaMP/MMM<br />

11. MMO/LaPO<br />

12. MMP/LaPP/MPO<br />

13. C17<br />

1. PE<br />

2. PI<br />

3. PS<br />

4. PC<br />

5. SM1<br />

6. SM2<br />

1. LACCER<br />

2. U<br />

3. PA<br />

4. PE<br />

5. PI<br />

6. PS<br />

7. PC<br />

8. SM1<br />

9. SM2<br />

10. LPC<br />

10578<br />

10577<br />

0 5 10 15 20 Min.<br />

Column: Alltech ® Prevail Silica, 3µm, 150 x 3.0mm (Part No. 99341)<br />

Mobile Phase: A: Chloroform B: Methanol C: Triethylamine buffer pH3<br />

Gradient: Time: 0 16 17<br />

%B: 12 60 12<br />

%C: 0.5 12 0.5<br />

Flow Rate: 0.5mL/min<br />

Detector: ELSD<br />

food & beverage<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

427


hplc applications<br />

1) Limonene<br />

1) p-Hydroxybenzoic acid<br />

2) Methylhydroxybenzoic acid<br />

3) Propylhydroxybenzoic acid<br />

food & beverage<br />

Oils / Lipids<br />

Limonene in Grapefruit Oil<br />

Column phase: GROM-SIL 80 ODS-2 FE, 5 µm<br />

Column size: 250 x 4 mm<br />

Eluent A: H2O / MeOH = 50 / 50<br />

B: ACN<br />

Gradient: 0 - 100% B (0-20 min)<br />

Flow rate: 0.8 ml/min<br />

Pressure: 16 MPa<br />

Temperature: RT<br />

1<br />

Detection (UV): 254 nm, 1.0 AUFS<br />

Injection: 2 µl oil<br />

1) Sorbic acid<br />

0 5 10 15 20 25 Min. 2) Benzoic acid 0 1 2 3 4 Min.<br />

Column: Grom Sil 80 ODS-2 FE, 5μm, 2503) x Saccharin 4mm<br />

Column:<br />

Mobile Phase: A: Water:Methanol (50:50) B: Acetonitrile<br />

Gradient: Time: 0 20<br />

%B: 0 100<br />

Flow Rate: 1.5mL/min<br />

Flow Rate: 0.8mL/min<br />

Sweeteners in beverages Detector: UV at 254nm<br />

Detector: UV at 254nm<br />

1<br />

2<br />

0 3 6 9 12 15 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Aflatoxins<br />

3<br />

Column phase:<br />

GROM-SIL 100 ODS-2 FE, 5 µm<br />

Column size:<br />

1. Sorbic 125 Acid x 3 mm<br />

2. Benzoic Eluent: Acid<br />

12 mM TBAH, 0.2 M Na-phosphate,<br />

pH 3.6 / H20 / ACN = 32 / 60 / 8<br />

Flow rate:<br />

0.4 ml/min<br />

Pressure:<br />

12 MPa<br />

Temperature:<br />

RT<br />

Detection (UV):<br />

230 nm<br />

Injection:<br />

Grom Sil 100 ODS-2 FE, 5μm, 125 x 3mm<br />

20 µl (50 µg/ml)<br />

12mM Tetrabutylammonium Hydroxide, 0.2M Sodium<br />

Phosphate, pH3.6:Water:Acetonitrile (32:60:8)<br />

0.4mL/min<br />

UV at 230nm<br />

1<br />

2<br />

3<br />

4<br />

1. Limonene<br />

Sweeteners in Beverages<br />

Aflatoxins<br />

3. Saccharin<br />

1. Aflatoxin B1<br />

2. Aflatoxin G1<br />

3. Aflatoxin B2<br />

4. Aflatoxin G2<br />

Additives<br />

1 2 3<br />

Limonene in Grapefruit Oil<br />

10437<br />

Analysis of Food Preservatives<br />

Column phase:<br />

GROM-SIL 120 ODS-3 CP, 5 µm<br />

1. p-Hydroxybenzoic Column size: Acid<br />

2. Methylhydroxybenzoic 125 x 4 mm Acid<br />

3. Propylhydroxybenzoic Eluent:<br />

Acid<br />

H20 / ACN = 50 / 50 (v/v)<br />

Flow rate:<br />

1.5 ml/min<br />

Pressure:<br />

15 MPa<br />

Temperature:<br />

RT<br />

Detection (UV):<br />

254 nm, 0.1 AUFS<br />

Injection:<br />

10 µl (~ 4 µg each) 1) Benzoic acid<br />

Grom Sil 120 ODS-3 CP, 5μm, 125<br />

2)<br />

x<br />

Caffeine<br />

4mm<br />

(Part No. 5115479)<br />

3) Aspartame<br />

Mobile Phase: Water:Acetonitrile (50:50)<br />

1<br />

2<br />

0 5 10 15 Min.<br />

3<br />

Analysis of Food Preservatives<br />

Aspartame in Soft Drinks<br />

1. Benzoic Acid<br />

2. Caffeine<br />

3. Aspartame<br />

Analysis of Aspartame in Soft Drinks<br />

Column phase: GROM-SIL 120 Phenyl-1<br />

5 µm<br />

Column size: 150 x 4 mm<br />

Eluent: 50 mM KH2PO4 / ACN /<br />

MeOH = 84 / 3 / 13<br />

Flow rate: 1.1 ml/min<br />

Pressure: 12 MPa<br />

Temperature: 30°C<br />

Detection (UV): 214 nm, 0.64 AUFS<br />

Injection: 10 µl<br />

1) G2a<br />

2) B2a<br />

3) G2<br />

4) B2<br />

3 4<br />

Column: Grom Sil 120 Phenyl-1 FE, 5μm, 150 x 4mm<br />

Mobile Phase: 50mM KH2PO4:Acetonitrile:Methanol Analysis (84:3:13) of Aflatoxins by HPLC<br />

1 2<br />

Flow Rate: 1.1mL/min<br />

Detector: UV at 214nm<br />

Aflatoxins<br />

1. G2a<br />

2. B2a<br />

3. G2<br />

4. B2<br />

Column phase:<br />

GROM-SIL 100 ODS-0 AB, 5 µm<br />

Column size:<br />

125 x 4mm<br />

Eluent:<br />

acetic acid / MeOH / H2O = 2 / 2 / 8<br />

Flow rate:<br />

0.6 ml/min<br />

Pressure:<br />

7 MPa<br />

Temperature:<br />

RT<br />

Detection (Fluor.):<br />

360 nm (exc.), 425 nm (em.)<br />

Injection: 10 µl (100 µg/ml)<br />

0 5 10 15 Min.<br />

Column: Alltech ® Alltima HP Silica, 5µm, 150 x 4.6mm<br />

(Part No. 87795)<br />

Mobile Phase: Methylene Chloride:Methanol:Water (99.35:0.5:0.15)<br />

Flow Rate: 0.8mL/min<br />

Detector: ELSD<br />

0 2 4 6 Min.<br />

Column: Grom Sil 100 ODS-0 AB, 5μm, 125 x 4mm<br />

Mobile Phase: Acetic Acid:Methanol:Water (2:2:8)<br />

Flow Rate: 0.6mL/min<br />

Detector: Fluoresence at 360nm (exc.), 425nm (em.)<br />

428<br />

www.discoverysciences.com


hplc applications<br />

Proteins & Peptides/Reversed-Phase<br />

1<br />

4 5 8<br />

7<br />

2 3<br />

6<br />

PTH Amino Acids<br />

PTH Amino Acids<br />

9<br />

10<br />

0 2 4 6 8 10 12 14 Min.<br />

11<br />

12<br />

13<br />

1416<br />

17<br />

15<br />

1. His<br />

2. Cys Acid<br />

3. Arg<br />

4. Asp<br />

5. Ser<br />

6. Gln<br />

7. Thr<br />

8. Gly<br />

9. Cys<br />

10. Ala<br />

11. Tyr<br />

12. Met<br />

13. Pro<br />

14. Trp<br />

15. Phe<br />

16. Ile<br />

17. Leu<br />

Column: Vydac ® Denali ® , 5µm, 150 x 4.6mm (Part No. 238DE5415)<br />

Mobile Phase: A: Acetonitrile:25mM Potassium Phosphate, pH3.3 (20:80)<br />

B: Acetonitrile:25mM Potassium Phosphate, pH3.3 (80:20)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

life science<br />

Intensity (cps)<br />

Column: DENALI 238DE5415 (5 µm, 4.6 mm i.d. x 150 mm)<br />

Flow:<br />

1.0 mL/min<br />

Eluent: A = 20:80 ACN:25 mM potassium phosphate, pH 3.3<br />

B = 80:20 ACN:25 mM potassium phosphate, pH 3.3<br />

0 to 75% B over T17 15 min<br />

Ambient (23 °C) 26.4<br />

Absorbance, 254 nm T18-20<br />

31.5 T26<br />

5 µL of PTH amino acid standard T13 39.4 mixture<br />

32.8<br />

T5<br />

1) His, 2) Cys acid, 3) Arg, 4) Asp, 5) Ser, 6) Gln, 54.4<br />

7) Thr, 8) Gly, 9) Cys, 10) Ala, 11) Tyr, 12) Met,<br />

T8<br />

13) Pro, 17.414) Trp, 15) Phe, 16) Ile, 17) Leu<br />

29.6<br />

33.2<br />

7.4<br />

T20 T11<br />

19.3 25.6<br />

33.7<br />

6.0e4 Gradient:<br />

5.5e4 Temp:<br />

5.0e4 Detection:<br />

4.5e4 Sample:<br />

4.0e4 Peaks:<br />

3.5e4<br />

3.0e4<br />

2.5e4<br />

2.0e4<br />

1.5e4<br />

1.0e4<br />

5000.0<br />

T7<br />

7.7 16.6<br />

TIC of Tryptic Digest of Green Fluorescent Protein (GFP): 150pmol Load on 1mm i.d.<br />

22.8<br />

38.7<br />

40.1<br />

5 10 15 20 25 30 35 40 45 50 55 60 65 70 Min.<br />

T9<br />

55.8<br />

57.2 T29<br />

60.2 64.7<br />

Column:<br />

Vydac ® , 250 x 1mm (Part No. 238EV51)<br />

Mobile Phase: A: Acetonitrile:0.05% Trifluoroacetic Acid (2:98)<br />

B: Acetonitrile:0.05% Trifluoroacetic Acid (90:10)<br />

Gradient: Time: 0 60<br />

%B: 5 65<br />

Flow Rate: 50μL/min<br />

Detector: ms: ABI QSTAR<br />

Injection Volume: 25μL GFP digest<br />

Mass Spectrum of Tryptic Digest of GFP<br />

Intensity (counts)<br />

6.5<br />

6.0<br />

5.5<br />

5.0<br />

4.5<br />

4.0<br />

3.5<br />

3.0<br />

2.5<br />

2.0<br />

1.5<br />

1.0<br />

T10<br />

790.361<br />

T5<br />

T26<br />

1220.139<br />

1492.071<br />

T8<br />

826.410<br />

T18-20<br />

1012.464<br />

T24<br />

507.293<br />

T17<br />

T9<br />

T13<br />

T11<br />

1050.523<br />

1208.645<br />

804.370<br />

T7<br />

655.384<br />

T20<br />

474.329 982.501<br />

827.416<br />

T19<br />

523.221 1041.482 T4<br />

579.315 1119.553<br />

847.384<br />

1312.674<br />

429.090<br />

752.342 1511.078<br />

0.5<br />

0.0<br />

400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600<br />

m/z<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

429


hplc applications<br />

life science<br />

Proteins & Peptides/Reversed-Phase<br />

Protein Mix<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

1. Ribonuclease A<br />

2. Cytochrome C<br />

3. Lysozyme Impurity<br />

4. Lysozyme<br />

5. Myoglobin Impurity<br />

6. Myoglobin<br />

0 5 10 15 Min.<br />

Column: Alltech ® ProSphere C4, 300Å, 5µm, 150 x 4.6mm<br />

(Part No. 33989)<br />

Mobile Phase: A: 0.15% Trifluoroacetic Acid<br />

B: 0.13% Trifluoroacetic Acid in Acetonitrile:Water (95:5)<br />

Gradient: Time: 0 15<br />

%B: 30 60<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

1<br />

Enzymes<br />

2<br />

8503 9068<br />

1. α-Chymotrypsinogen<br />

2. Carbonic Anhydrase<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: Alltech ® ProSphere C4, 300Å, 5µm, 150 x 4.6mm<br />

(Part No. 33989)<br />

Mobile Phase: A: 0.15% Trifluoroacetic Acid in Water<br />

B: 0.13% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 15<br />

%B: 40 55<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

Insulins<br />

Bradykinins<br />

1<br />

3<br />

1. Bovine Insulin<br />

2. Bovine Insulin Impurity<br />

3. Porcine Insulin<br />

4. Porcine Insulin Impurity<br />

9082<br />

1<br />

2<br />

1. des-Pro 2 -bradykinin<br />

2. Bradykinin<br />

9062<br />

2<br />

4<br />

0 2<br />

4 6 8 10 12 Min. 0<br />

Column: Alltech ® ProSphere C18, 300Å, 5µm, 150 x 4.6mm<br />

(Part No. 32969)<br />

Mobile Phase: A: 0.13% Trifluoroacetic Acid in Water<br />

B: 0.10% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 12<br />

%B: 28 38<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

2 4 6 8 10 12 14 Min.<br />

Column: Alltech ® ProSphere C18, 300Å, 5µm, 150 x 4.6mm<br />

(Part No. 32969)<br />

Mobile Phase: A: 0.15% Trifluoroacetic Acid in Water<br />

B: 0.13% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 15<br />

%B: 15 25<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 205nm<br />

430<br />

www.discoverysciences.com


hplc applications<br />

Proteins & Peptides/Reversed-Phase<br />

Bioactive Peptides<br />

1<br />

2<br />

3<br />

4<br />

5<br />

1. Methionine Enkephalin<br />

2. Bradykinin<br />

3. Leucine Enkephalin<br />

4. Physalaemin<br />

5. Substance P<br />

2<br />

Peptides<br />

8502<br />

3 4 9066<br />

5<br />

1. GLY-TYR<br />

1<br />

2. VAL-TYR-VAL<br />

3. Methionine Enkephalin<br />

4. Leucine Enkephalin<br />

5. Angiotensin II<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: Alltech ® ProSphere C18, 300Å, 5µm, 150 x 4.6mm<br />

(Part No. 32969)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.085% Trifluoroacetic Acid in Acetonitrile:Water (95:5)<br />

Gradient: Time: 0 20<br />

%B: 20 50<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: Alltech ® ProSphere C18, 300Å, 5µm, 150 x 4.6mm<br />

(Part No. 32969)<br />

Mobile Phase: A: 0.15% Trifluoroacetic Acid in Water<br />

B: 0.13% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 15<br />

%B: 10 30<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

life science<br />

2<br />

4<br />

3<br />

Peptide Mix<br />

1. Oxytocin<br />

2. Angiotensin II<br />

3. Angiotensin I<br />

4. Eledosin<br />

10199<br />

β-Lactoglobulin A Tryptic Digest<br />

9092<br />

1<br />

0 2 4 6 8 10 12 14 16 Min. 0 5 10 15 20 25 30 35 40 45 Min.<br />

Column: Alltech ® ProSphere C18, 100Å, 5µm, 250 x 4.6mm Column: Alltech ® ProSphere C18, 300Å, 5µm, 150 x 4.6mm<br />

(Part No. 35087)<br />

(Part No. 32969)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

Mobile Phase: A: 0.15% Trifluoroacetic Acid in Water<br />

B: 0.1% Trifluoroacetic Acid in Acetonitrile:Water (90:10)<br />

B: 0.13% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 20<br />

Gradient: Time: 0 45<br />

%B: 20 50<br />

%B: 5 30<br />

Flow Rate: 1.0mL/min<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

Detector: UV at 220nm<br />

Monoclonal Antibody Tryptic Digest<br />

10213<br />

0 20 40 60 80 100 120 140 160 Min.<br />

Column: Alltech ® ProSphere C18 100Å, 5µm, 250 x 4.6mm<br />

(Part No. 35087)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.08% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 160<br />

%B: 0 45<br />

Flow Rate: 0.5mL/min<br />

Detector: UV at 220nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

431


hplc applications<br />

life science<br />

Proteins & Peptides/Reversed-Phase<br />

Peptide Mix on 300Å<br />

1<br />

2 3<br />

4<br />

1. Methionine Enkephalin<br />

2. Leucine Enkephalin<br />

3. Angiotensin II<br />

1<br />

4. Neurotensin<br />

5. Angiotensin I<br />

5 6. Substance P<br />

6<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

10363<br />

Column: Alltech ® ProSphere C18, 300Å, 5µm, 150 x 4.6mm<br />

(Part No. 32969)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.08% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 20<br />

%B: 20 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

Phosphopeptides and Fibrinopeptide<br />

2<br />

3<br />

0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Min.<br />

4<br />

1. Monophosphopeptide<br />

(FQpSEEQQTEDELQDK)<br />

2. [Glu 1 ]-Fibrinopeptide B<br />

(EGVNDNEEGFFSAR)<br />

3. Tetraphosphopeptide<br />

(RELEELNVPGEIVEpSLpSpSpSEESITR)<br />

4. Contaminant(s)<br />

Column: Vydac ® ProZap C18, 2.1 x 10mm<br />

HPLC System: HPG binary pump<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.085% Trifluoroacetic Acid in Acetonitrile:Water (80:20)<br />

Gradient: Time: 0.0 1.0 1.1 1.3 1.4<br />

%B: 12 60 80 80 12<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 215nm<br />

1<br />

Peptide Mix on 190Å<br />

5<br />

6<br />

3<br />

2<br />

4<br />

1. Methionine Enkephalin<br />

2. Leucine Enkephalin<br />

3. Angiotensin II<br />

4. Neurotensin<br />

5. Angiotensin I<br />

6. Substance P<br />

10369<br />

BSA Tryptic Digest<br />

10582<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column: Alltech ® Alltima HP C18, 190Å, 5µm, 250 x 4.6mm<br />

(Part No. 87679)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.08% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 20<br />

%B: 20 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

0 5 10 15 20 25 30 35 40 45 50 55 Min.<br />

Column: Vydac ® 218MS C18, 5µm, 150 x 0.075mm<br />

(Part No. 218MS5.07515)<br />

Mobile Phase: A: Water with 0.1% Formic Acid:Acetonitrile (95:5)<br />

B: Water with 0.1% Formic Acid:Acetonitrile (20:80)<br />

Gradient: Time: 0 5 50 60<br />

%B: 0 0 50 100<br />

Flow Rate: 0.25µL/min<br />

Peptide Mix on 100Å<br />

1 3<br />

2<br />

4<br />

5<br />

6<br />

10370<br />

1. Methionine Enkephalin<br />

2. Leucine Enkephalin<br />

3. Angiotensin II<br />

4. Neurotensin<br />

5. Angiotensin I<br />

6. Substance P<br />

11111<br />

234<br />

Amino Acids by HILIC<br />

61<br />

51<br />

17<br />

10582<br />

1. Glutamic Acid<br />

2. Leucine<br />

3. Serine<br />

4. Glycine<br />

6. Lysine<br />

7. Arginine<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column: Alltech ® ProSphere C18, 100Å, 5µm, 250 x 4.6mm<br />

(Part No. 35091)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.08% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 20<br />

%B: 20 40<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

0 1 2 3 4 5 6 7 8 9 10 11 Min.<br />

Column: Alltech ® Alltima HP HILIC, 150 x 4.6mm<br />

Mobile Phase: Acetonitrile:10mM Ammonium Acetate with<br />

0.2% Acetic Acid (70:30)<br />

Flow Rate: 0.75mL/min<br />

Detector: ELSD<br />

432<br />

www.discoverysciences.com


hplc applications<br />

Proteins & Peptides/Reversed-Phase<br />

LC-MS of Proteins<br />

3<br />

2<br />

Column: Vydac ® ProZap C18, 2.1 x 10mm<br />

Mobile Phase: A: 0.2% Formic Acid, 0.01% Trifluoroacetic Acid in Acetonitrile:Water (5:95)<br />

B: 0.2% Formic Acid, 0.01% Trifluoroacetic Acid in Acetonitrile:Water (80:20)<br />

2<br />

Gradient: Time: 0 4.0 4.5 4.7<br />

4<br />

%B: 20 90 90 20<br />

Flow Rate: 0.4mL/min<br />

Detector: AB/MDS Sciex Q TRAP ® MS. EMS scan 400-1700 1 amu;<br />

scan rate = 1000 amu/s; ion spray voltage = 5000 V; LIT fill time = 50 ms;<br />

1<br />

Q3 entry barrier = 8V; declustering potential = 20; collision energy<br />

3<br />

= 10 eV;<br />

curtain gas = 50; ion source gas 1 = 45; ion source gas 2 = 70;<br />

temperature (TEM) = 350°C.<br />

Left Chromatogram Injection Amount: 50 ng each<br />

0 1 2 3 4 5 Min. Right Chromatogram Injection Amount: 8µg each, 0 except 1 1.5µg 2for growth 3 hormone 4 5 Min.<br />

life science<br />

1. Bovine Cytochrome C, M =12222 (ave.)<br />

2. Horse Apomyoglobin, M = 16941 (ave.)<br />

3. Bovine Carbonic Anhydrase II, M = 28998 (ave.)<br />

4. Chicken Ovalbumin, M = 44455 (ave.)<br />

Peak 1 - Peak Bovine 1 - Cytochrome Bovine Cytochrome C C<br />

Peak 2 - Peak Horse 2 Apomyoglobin<br />

- Horse Apomyoglobin<br />

941.0 941.0<br />

+19+18+17+16 +15 +19+18+17+16 +14 +13 +15 +12 +14 +11 +13 +12 +10 +11 +9 +10 +9<br />

892.6 892.6<br />

+27+26+25+24+23+22+21+20 848.1 +27+26+25+24+23+22+21+20 +19 +18 848.1+17 +16 +19 +18 +15 +17 +14 +16 +13 +15 +14 +12 +13 +11 +12 +11<br />

942.2 942.2<br />

2.4<br />

2.0<br />

2.4<br />

2.0<br />

815.9<br />

765.1<br />

815.9<br />

874.0<br />

765.1<br />

874.0<br />

5<br />

4<br />

5<br />

4<br />

808.0<br />

808.0<br />

997.2<br />

997.2<br />

1.6 1.6<br />

1019.2 1019.2<br />

720.2 720.2<br />

1.2 1.2<br />

1112.1 1112.1<br />

0.8 0.8<br />

447.0 447.0 1223.0 1223.0<br />

680.4 680.4 1358.4 1358.4<br />

483.0 483.0<br />

0.4 0.4 644.7 644.7<br />

417.0 541.9 417.0 719.0 541.9 719.0 945.8 945.8<br />

674.0 740.5 674.0 856.7 740.5 996.2 856.7 1120.2 996.2 1120.2<br />

1528.3 1528.3<br />

569.8 707.569.8 707.5 888.6 888.6 1232.4 1232.4<br />

0 0<br />

400 400 600 600 800 800 1000 1000 1200 1200 1400 1400 1600 1600<br />

m/z m/z<br />

1059.7 1059.7<br />

3 3<br />

771.3 771.3<br />

2 2<br />

737.9 737.9<br />

1130.3 1304.0 1130.3 1304.0<br />

1210.7 1210.7<br />

1 1<br />

1412.6 1412.6<br />

447.0 447.0 707.0 707.0<br />

895.21132.8<br />

1132.8 1322.6 1322.6<br />

679.1 679.1 895.2<br />

425.0 425.0 740.1 805.0 740.1 805.0 1000.9 1000.9<br />

1216.9 1541.0 1541.0<br />

519.0 519.0 1216.9<br />

541.0 715.6 541.0 715.6 960.7 1090.7 960.7 1090.7 1694.9 1694.9<br />

1011.8 1011.8 1245.9 1411.61245.9 1411.6<br />

1187.8 1187.8 1578.6 1578.6<br />

400 400 600 600 800 800 1000 1000 1200 1200 1400 1400 1600 1600<br />

m/z m/z<br />

2.0<br />

1.8<br />

1.6<br />

1.4<br />

1.2<br />

1.0<br />

0.8<br />

447.0<br />

2.0<br />

1.8<br />

1.6<br />

1.4<br />

1.2<br />

1.0<br />

0.8<br />

425.1<br />

425.1<br />

0.6 0.6<br />

0.4<br />

0.2<br />

Peak 3 - Peak Bovine 3 - Carbonic Bovine Carbonic Anhydrase Anhydrase II II<br />

807.2<br />

907.1<br />

907.1<br />

+52 +51 +50 +49 +48 +47 +46 +45 +44 +43 +42 +41 +40 +39+38+37+36+35+34+33+32+31+30+29+28 +52 +51 +50 +49 +48 +47 +46 +45 +44 +43 +42 +41 +40 +39+38+37+36+35+34+33+32+31+30+29+28 +27 +26 +25 +24 +27 +23 +26 +22 +25 +21 +24 +23 +20 +22 +19 +21 +20 +19<br />

879.2<br />

879.2<br />

852.9<br />

852.9<br />

935.4<br />

935.4<br />

881.1 1037.1 881.1 1037.1<br />

966.6<br />

966.6<br />

1000.0<br />

1000.0<br />

447.0<br />

828.5<br />

807.2 968.5 968.5 828.5<br />

1116.4<br />

1116.4<br />

764.1<br />

764.1<br />

1161.2<br />

1161.2<br />

893.4<br />

893.4<br />

1266.8<br />

1266.8<br />

744.1 784.9 744.1 784.9<br />

1319.3<br />

1319.3<br />

416.9 416.9 765.9 871.5 948.1 765.9 871.5 948.1 1209.4<br />

1209.4<br />

1038.3<br />

1038.3<br />

505.0<br />

505.0<br />

1451.1<br />

1451.1<br />

482.90.4<br />

482.9 726.1 799.2 912.0726.1955.7<br />

799.2 912.01060.1 955.7 1160.3 1060.1 1160.3<br />

978.6<br />

978.6<br />

1381.9<br />

1381.9<br />

467.1 593.2 467.1 689.3 593.2 689.3<br />

691.8 691.8 930.7 1052.5 930.7 1131.7 1323.4 1052.5 1131.7 1323.41527.6<br />

1527.6<br />

525.90.2<br />

525.9<br />

992.3 992.3 1353.0<br />

1353.0<br />

418.7 590.8418.7<br />

630.3 590.8 630.3 776.6 776.6 1452.4 1612.2 1452.4 1612.2<br />

1231.8 1330.0 1231.8 1330.01477.2<br />

1477.2<br />

1363.2<br />

1363.2<br />

400 400 600 600 800 800 1000 1000 1200 1200 1400 1400 1600 1600<br />

m/z m/z<br />

4<br />

3<br />

2<br />

1<br />

0<br />

615.9<br />

4<br />

3<br />

2<br />

621.0 678.8 729.9621.0<br />

678.8 882.8 1184.7 1471.9<br />

1184.7 1471.9<br />

729.9 1643.9<br />

882.8 1643.9<br />

1313.2<br />

1313.2<br />

1355.0 1355.0 1464.9 1527.0 1464.9 1527.0<br />

736.9 635.8 774.1 1248.2<br />

736.9 895.8 774.1 1248.2 1480.2<br />

895.8 1480.2<br />

635.8 1655.9<br />

1655.9<br />

1<br />

Peak 4 - Peak Chicken 4 - Chicken Ovalbumin Ovalbumin<br />

940.7<br />

940.7<br />

+35 +34 +33 +32 +35 +31 +34 +30 +33 +29<br />

1012.2<br />

+32 +31 +30 +29<br />

1012.2<br />

961.8<br />

961.8<br />

997.7 1048.0 997.71163.3<br />

1048.0 1163.3<br />

1054.7 1077.2 1140.3 1054.7 1077.2 1140.3 1348.3<br />

1348.3<br />

955.4<br />

955.4 1235.6 1235.6 1482.8 1521.6 1482.8 1521.6<br />

615.9 919.3 919.3 1005.1 1131.4 1005.1 1131.4 1387.9<br />

1387.9<br />

967.5 967.5 1229.1<br />

1229.1 1434.1<br />

1434.1 1639.3<br />

1639.3<br />

908.3 1088.1 908.3 1117.8 1088.1 1117.8 1257.0 1396.0 1257.0 1396.0<br />

872.4<br />

945.8 872.4<br />

945.8 1200.3 1200.3 1592.7<br />

1592.7<br />

897.6 897.6 1114.9 1114.9 1282.0 1351.1 1282.0 1351.1 1515.4<br />

1515.4<br />

700<br />

0<br />

700 900 9001100 11001300 13001500 15001700<br />

1700<br />

m/z m/z<br />

1520.3 1637.8 1520.3 1637.8<br />

669.8 753.0 669.8<br />

694.5 1365.2 1502.3<br />

843.5 694.5 1365.2 1502.31610.7<br />

753.0 843.5 1610.7<br />

1569.6<br />

1569.6<br />

1664.3<br />

1664.3<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

433


hplc applications<br />

Proteins & Peptides/Reversed-Phase<br />

LC-MS of Proteins<br />

life science<br />

1<br />

2<br />

0 1 2 3 4 5 Min.<br />

1. Human Insulin, M = 5803 (ave.)<br />

2. Human Serum Albumin, M = 66520 (ave.)<br />

3. Human Growth Hormone, M = 22123 (ave.)<br />

3<br />

Column: Vydac. ® ProZap C18, 2.1 x 10mm<br />

Mobile Phase: A: 0.2% Formic Acid, 0.01% Trifluoroacetic Acid in Acetonitrile:Water (5:95)<br />

B: 0.2% Formic Acid, 0.01% Trifluoroacetic Acid in Acetonitrile:Water (80:20)<br />

Gradient: Time: 0 4.0 4.5 4.7<br />

%B: 20 90 90 20<br />

Flow Rate: 0.4mL/min<br />

Detector: AB/MDS Sciex Q TRAP ® MS. EMS scan 400-1700 amu;<br />

scan rate = 1000 amu/s; ion spray voltage = 5000 V; LIT fill time = 50 ms;<br />

Q3 entry barrier = 8V; declustering potential = 20; collision energy = 10 eV;<br />

curtain gas = 50; ion source gas 1 = 45; ion source gas 2 = 70;<br />

temperature (TEM) = 350°C.<br />

Left Chromatogram Injection Amount: 50 ng each<br />

Right Chromatogram Injection Amount: 8µg each, except 1.5µg for growth hormone<br />

Intensity (x 10 6 cps)<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

Intensity (x 10 6 cps)<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

Peak 1 -Human Peak 1 -Human Insulin Insulin<br />

Peak 2 Peak - Human 2 - Human Serum Serum Albumin Albumin<br />

1161.4<br />

1451.6<br />

+7 1161.4 +6 +5 1451.6<br />

+7 +6 +5<br />

968.1<br />

968.1<br />

1453.1<br />

1474.5<br />

827.6<br />

1453.1<br />

1262.3<br />

1158.0 1180.4<br />

446.0 651.8 969.8 1040.1<br />

608.8 1474.5<br />

827.6 755.6 1465.1<br />

943.6 1340.1 1500.6<br />

817.9 1685.4<br />

1158.0 1180.4<br />

446.0 608.8 651.8<br />

400 755.6600 817.9 943.6 969.8<br />

800<br />

1040.1<br />

10001262.3<br />

1340.1 12001465.1<br />

1500.6 1400 1685.4 1600<br />

400 600 800 1000 1200 1400 1600<br />

m/z<br />

m/z<br />

Intensity (x 10 5 cps)<br />

2.0<br />

2.0<br />

1.6<br />

1.2<br />

0.8<br />

0.4<br />

1473.4<br />

+59+58 +57 +56 +55 +54 +53 +52 +51 +50 +49 1473.4 +48 +47 +46 +45 +44 +43 +42 +41<br />

+56 +55 +54 +53 +52 +51 +50 +49 +48 +47 +46 +45 +44 +43 +42 +41<br />

+59+58 +57<br />

1542.8<br />

1542.8<br />

1478.8<br />

1387.2<br />

1387.2<br />

1478.8<br />

1408.8<br />

1408.8 1446.9<br />

1.6<br />

1446.9 1620.6<br />

1331.9<br />

1415.8<br />

1620.6<br />

1513.0<br />

1331.9 1415.8 1360.0<br />

1444.9 1513.0<br />

1360.0 1305.0<br />

1.2<br />

1305.0<br />

1444.9 1356.5<br />

1547.8<br />

1281.2 1356.5<br />

1393.9 1547.8<br />

1389.7<br />

1475.7<br />

1281.2 1393.9<br />

1509.8<br />

1389.7 1329.2 1420.9<br />

1255.1<br />

1621.8<br />

1420.9 1399.6<br />

1475.7 1509.8<br />

1255.1<br />

1452.2<br />

1329.2<br />

1335.1<br />

1621.8<br />

0.8<br />

1282.7 1399.6<br />

1552.8<br />

1256.1<br />

1492.8 1585.0<br />

1335.1<br />

1452.2<br />

1403.5 1464.8<br />

1282.7 1552.8<br />

1256.1<br />

1363.5 1492.8 1585.0<br />

1529.4<br />

1323.6 1403.5 1464.8<br />

1582.6 1646.6<br />

1213.7<br />

1423.9<br />

1240.21363.5 1529.4<br />

1489.3<br />

1317.5 1537.4<br />

1582.6 1323.6 1646.6<br />

1213.7<br />

1266.7<br />

1423.9<br />

1240.2 1189.2 1489.3 1505.8<br />

1265.1 1599.8 1657.5<br />

1317.5<br />

0.4<br />

1189.2 1168.5 1266.7 1265.1 1270.7<br />

1537.4<br />

1319.3<br />

1376.3 1576.4<br />

1505.8<br />

1599.8 1657.5<br />

1220.2<br />

1642.9 1694.3<br />

1130.4<br />

1319.3 1376.3 1576.4<br />

1150.7 1168.5 1143.7 1220.2<br />

1642.9<br />

1567.8<br />

1087.5<br />

1270.7 1694.3<br />

1016.5 1678.7<br />

1130.4 1150.7 1567.8<br />

1087.5 1143.7<br />

1016.5 1678.7<br />

Intensity (x 10 5 cps)<br />

1100 1200 1300 1400 1500 1600 1700<br />

1100 1200 1300 1400 1500 1600 1700<br />

m/z<br />

m/z<br />

Intensity (x 10 5 cps)<br />

2.0<br />

1.8<br />

1.6<br />

Intensity (x 10 5 cps)<br />

1.4<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

2.0<br />

1.8<br />

1.6<br />

1.4<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

447.0<br />

447.0 483<br />

418.9<br />

483.0<br />

418.9<br />

0.2 504.9 524<br />

524.9 6<br />

400<br />

400<br />

Peak 3 - Human Growth Hormone<br />

2.0<br />

1474.5<br />

+26+25+24 +23 +22 +21 +20 +19 +18 +17 +16 +15<br />

+43 +42 +41<br />

.8<br />

1620.6<br />

7.8<br />

1621.8<br />

2.8 1585.0<br />

1582.6 1646.6<br />

1599.8 1657.5<br />

6.4<br />

1642.9 1694.3<br />

1567.8<br />

1678.7<br />

1600 1700<br />

Intensity (x 10 5 cps)<br />

1.8<br />

1.6<br />

1.4<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

1054.4<br />

1107.4<br />

1165.4<br />

1164.6<br />

1229.1<br />

1302.1<br />

1382.5<br />

1579.7<br />

483.0<br />

447.0<br />

1006.3<br />

1231.3<br />

1108.6 1388.7<br />

962.6<br />

418.9 504.9 664.2<br />

1307.3<br />

964.8 1136.3<br />

1201.1<br />

922.4<br />

714.9<br />

1374.0<br />

524.9 1587.4<br />

885.6<br />

602.9 629.7 1493.8<br />

1248.4 1396.8<br />

989.5 1127.3 1604.4<br />

1032.9<br />

822.3 1528.7<br />

400 600 800 1000 1200 1400 1600<br />

m/z<br />

434<br />

www.discoverysciences.com


hplc applications<br />

Proteins & Peptides/Reversed-Phase<br />

Human Growth Hormone (hGH) Assay on 300Å C4 Columns<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1 2<br />

0 20 40 60Min.<br />

1. Desamido hGH<br />

2. hGH<br />

2<br />

VYDAC ® MS C4 Column<br />

Competitor 1 C4 Column<br />

Competitor 2 C4 Column<br />

Competitor 3 C3 Column<br />

Columns: Vydac ® MS C4 (Part No. 214MS54), Competitor 1 C4, Competitor 2 C4, and Competitor 3 C3<br />

(all 300Å, 250 x 4.6mm packed with 5µm except 4µm for Competitor 1)<br />

Mobile Phase: 50mM Tris, pH7.5:n-Propanol (71:29)<br />

Flow Rate: 0.5mL/min<br />

Detector: UV at 220nm<br />

life science<br />

1<br />

2 4<br />

4<br />

1<br />

4<br />

3<br />

2<br />

4<br />

1 3<br />

4<br />

2<br />

1<br />

3<br />

2<br />

1 2<br />

10 20 30 40 50 60 65 Min.<br />

Transmembrane Protein p14 on 300Å C4 Columns<br />

VYDAC ® MS C4 Column<br />

Competitor 1 C4 Column<br />

Competitor 2 C3 Column<br />

Competitor 3 C4 Column<br />

Competitor 4 C4 Column<br />

1. 18.8 kD Protein<br />

2. Non-myristoylated p14<br />

3. Myristoylated p14<br />

4. Triton X (Surfactant)<br />

Columns: Vydac ® MS C4 (Part No. 214MS54), Competitor 1 C4, Competitor 2 C3, Competitor 3 C4, and Competitor 4 C4<br />

(all 300Å, 250 x 4.6mm packed with 5µm except 4µm for Competitor 1)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water B: 0.085% Trifluoroacetic Acid in Acetonitrile<br />

Gradient Vydac ® , Comp. 1, & Comp. 2: Time: 0 20 25 45<br />

%B: 20 60 80 80<br />

Gradient Comp. 3 & Comp. 4: Time: 0 20 25 45 50 80<br />

%B: 20 60 80 80 90 90<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 215nm<br />

Tryptic Digest of Fetuin on 300Å C18 Columns<br />

VYDAC ® MS C18<br />

Column<br />

Competitor 1 C18<br />

Column<br />

Competitor 2 C18<br />

Column<br />

0 20 40 60 80 Min.<br />

Columns: Vydac ® MS C18 (Part No. 238MS5415), Competitor 1 C18, and Competitor 2 C18 (all 300Å, 5µm, 150 x 4.6mm)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water B: 0.085% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 5 80 90 100<br />

%B: 4 4 40 90 90<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 215nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

435


hplc applications<br />

life science<br />

Intensity (x 10 6 cps)<br />

Proteins & Peptides/Reversed-Phase<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

Base Peak Chromatogram of<br />

Tryptic Digest of BSA<br />

0<br />

0 5 15 25 35 45 55 65 75 85 95 Min.<br />

Column: Vydac ® Everest ® C18, 300Å, 5µm, 300µm x 150mm<br />

(Part No. 238EV5.315)<br />

Mobile Phase: A: 0.1% Formic Acid in Water<br />

B: 0.1% Formic Acid in Acetonitrile<br />

Gradient: Time: 0 5 75 85 95<br />

%B: 4 4 40 90 90<br />

Flow Rate: 5µL/min<br />

Column Temp: 22ºC<br />

Peptide Load: 0.1µL injection of 5.8µg/µL (580ng or 9pmol)<br />

MS Detector: AB/MDS Sciex Q-Trap.<br />

Human Apolipoproteins<br />

Standard<br />

Human Apolipoproteins<br />

7<br />

4 6 5<br />

1 2 3<br />

0 5 10 15 20 25 30 35 Min.<br />

8<br />

11<br />

10<br />

Column: Vydac ® C18, 5µm, 250 x 4.6mm (Part No. 218TP54)<br />

Column: Mobile Phase: VYDAC A: 218TP54 Acetonitrile:0.1% (C18, 5 µm, Trifluoroacetic 4.6 mm i.d. x 250 Acid mm) (25:75)<br />

Flow:<br />

1.2 mL/min B: Acetonitrile:0.1% Trifluoroacetic Acid (58:42)<br />

Temp: Gradient: 50 °CTime: 0 33<br />

Eluent: A = 25% %B: ACN/0.1% 0 100 TFA in water<br />

Flow Rate: B = 58% 1.2mL/min ACN/0.1% TFA in water<br />

Gradient: 0-100% B in 33 min<br />

Detector: UV<br />

Peaks: 1. apoC-IIIa; 2. apoC-IIIb; 3. apoC-IIa; 4. apoC-IIIc;<br />

5. apoC-I; 6. apoC-IIb; 7. apoA-Ia; 8. apoA-Ib;<br />

9. apoA-IIc; 10. apoA-IIa; and 11. apoA-IIb.<br />

The standard was human insulin.<br />

9<br />

1. ApoC-IIIa<br />

2. ApoC-IIIb<br />

3. ApoC-IIa<br />

4. ApoC-IIIc<br />

5. ApoC-I<br />

6. ApoC-IIb<br />

7. ApoA-Ia<br />

8. ApoA-Ib<br />

9. ApoA-IIc<br />

10. ApoA-IIa<br />

11. ApoA-IIb<br />

Insulin Variants<br />

1<br />

Insulin Variants<br />

2<br />

6<br />

4 5<br />

3<br />

7<br />

8<br />

1. chicken<br />

2. bovine<br />

1. 3. ovine Chicken<br />

2. 4. rabbit Bovine<br />

3. 5. human Ovine<br />

4. 6. porcine Rabbit<br />

5.<br />

7. rat<br />

Human<br />

I<br />

6.<br />

8. rat<br />

Porcine<br />

II<br />

7. Rat I<br />

8. Rat II<br />

Ribosomal Proteins<br />

Ribosomal Proteins<br />

0 5 10 15 20 25 Min.<br />

Column: Vydac ® C4, 5µm, 250 x 4.6mm (Part No. 214TP54)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid<br />

Column: VYDAC B: 214TP54 Acetonitrile (C4, 5 µm, 4.6 mm i.d. x 250 mm)<br />

Gradient: 27 to 30% Time: ACN 0 with 25 0.1% TFA over 25 min<br />

%B: 27 30<br />

Detector: UV<br />

0 60 120 180 240 300 360 Min.<br />

Column: Vydac ® C4, 5µm, 250 x 4.6mm (Part No. 214TP54)<br />

Column:<br />

Mobile Phase:<br />

VYDAC<br />

A:<br />

214TP54<br />

0.1%<br />

(C4,<br />

Trifluoroacetic<br />

5 µm, 4.6 mm<br />

Acid<br />

i.d. x 250 mm)<br />

Eluent: 10-38% B: isopropanol Isopropanol with 0.1% TFA over 355 min<br />

Gradient: Time: 0 355<br />

%B: 10 38<br />

Detector: UV<br />

Tryptic Tryptic Digest of Digest Bovine Serum of Bovine Albumin Serum Albumin<br />

Tryptic Digest of Fetuin (a Glycoprotein)<br />

Tryptic Digest of Fetuin (a Glycoprotein)<br />

436<br />

0 10 20 30 40 50 60 70 Min.<br />

Column: Vydac ® Everest ® C18, 5µm, 150 x 4.6mm<br />

Columns: EVEREST (Part 238EV5415 No. 238EV5415) and<br />

Mobile Phase: four commercial A: 0.1% Trifluoroacetic 300 Å Acid in Water<br />

reversed-phase B: 0.085% columns Trifluoroacetic Acid in Acetonitrile<br />

Gradient: (all C18, Time: 5 µm, 4.6 0 mm i.d. 5 x 150 80 mm) 90 100<br />

Flow: 1.0 mL/min<br />

%B: 4 4 40 90 90<br />

Eluent: A = 0.1% v/v TFA in water<br />

Flow Rate: B = 0.085% 1.0mL/min v/v TFA in ACN<br />

Gradient: Detector: 4% B for UV 5 at min, 215nm 4-40% B in 75 min,<br />

40-90% B in 10 min, hold 90% B<br />

for 10 min<br />

Detector: www.discoverysciences.com<br />

Absorbance, 215 nm<br />

Temp: 22 °C<br />

Sample: 30 µL of a 5.8 µg/µL digest<br />

0 10 20 30 40 50 60 70 80 Min.<br />

Column: Vydac ® Everest ® C18, 5µm, 150 x 4.6mm<br />

Columns: EVEREST (Part 238EV5415 No. 238EV5415) and<br />

Mobile Phase: four commercial A: 0.1% Trifluoroacetic 300 Å Acid in Water<br />

reversed-phase columns<br />

B: 0.085% Trifluoroacetic Acid in Acetonitrile<br />

(all C18, 5 µm, 4.6 mm i.d. x 150 mm)<br />

Gradient: Time: 0 5 80 90 100<br />

Flow: 1.0 mL/min<br />

Eluent: A = 0.1% %B: v/v TFA 4 in water 4 40 90 90<br />

Flow Rate: B = 0.085% 1.0mL/min v/v TFA in ACN<br />

Detector:<br />

Gradient: 4% B for UV 5 at min, 215nm 4-40% B in 75 min,<br />

40-90% B in 10 min, hold 90% B<br />

for 10 min<br />

Detector: Absorbance, 215 nm<br />

Temp: 22 °C<br />

Sample: 30 µL of a 6 µg/µL digest


hplc applications<br />

Proteins & Peptides/Reversed-Phase<br />

Peptides on 238MS C18 Column with Various Modifiers<br />

Peptides on 238MS C18 Column<br />

with Various Modifiers<br />

In order to demonstrate the effects of mobile phase modifiers and<br />

modifier concentrations, a mixture of six peptides was separated on<br />

a monomeric C18 MS column under identical gradient conditions<br />

with a variety of ion-pair reagents. Significant differences in selectivity<br />

arise depending on the concentrations and identities of the ions<br />

present in the mobile phase. Perfluorinated Acidic modifiers even<br />

at very low levels (0.005% w/v) produce increased retention. For<br />

this particular mixture, the best spread of peaks was obtained with<br />

heptafluorobutyric Acid (HFBA) at 0.02% (w/v). However, this might<br />

be expected to differ for other peptides.<br />

Column:<br />

Gradient:<br />

Flow Rate:<br />

Detector:<br />

Sample:<br />

Vydac ® Monomeric C18, 5µm, 250 x 4.6mm<br />

(Part No. 238MS54)<br />

10 to 40% Acetonitrile over 30 min for all<br />

chromatograms with constant concentration<br />

of modifier as indicated (w/v)<br />

1.0mL/min<br />

UV at 220nm<br />

Oxytocin, Bradykinin, Angiotensin II, Eledoisinrelated<br />

Peptide, Neurotensin, and Angiotensin I<br />

5 mM HOAc<br />

5 mM Formic Acid<br />

0.02% TFA<br />

0.005% TFA<br />

life science<br />

0.005% TFA + 0.1% HOAc<br />

0.005% TFA + 0.1% Formic Acid<br />

0.02% HFBA<br />

0.005% HFBA<br />

0.005% HFBA + 0.1% HOAc<br />

0 5 10 15 20 25 Min.<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

437


hplc applications<br />

Proteins & Peptides/Reversed-Phase<br />

Peptides<br />

Fast Protein Analysis<br />

5<br />

life science<br />

1<br />

2<br />

3<br />

4<br />

1. GY (238 Da)<br />

2. VYV (379 Da)<br />

3. Met Enkephalin (YGGFM, 573 Da)<br />

4. Leu Enkephalin (YGGFL, 555 Da)<br />

5. Angiotensin II (DRVYIHPF, 1045 Da)<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

1. Ribonuclease (37ng)<br />

2. Bovine Insulin (37ng)<br />

3. Cytochrome C (37ng)<br />

4. Lysozyme (4ng)<br />

5. Bovine Serum Albumin (37ng)<br />

6. Carbonic Anhydrase (37ng)<br />

7. Ovalbumin (37ng)<br />

0 0.2 0.4 0.6 0.8 1.0 1.2 Min.<br />

Column: Vydac ® ProZap C18, 500Å, 1.5µm, 10 x 2.1mm<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.085% Trifluoroacetic Acid:Acetonitrile (20:80)<br />

Gradient: Time: 0 0.1 0.7 1.1 1.2<br />

%B: 4 15 20 50 4<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 215nm<br />

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Min.<br />

Column: Vydac ® ProZAP C18, 1.5µm, 10 x 2.1mm<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.085% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 4.0 4.5 4.7<br />

%B: 23 75 75 23<br />

Flow Rate: 0.2mL/min<br />

Detector: UV at 280nm<br />

Antibodies in Sheep Serum on ProZap<br />

Synthetic Peptides-10 Injections<br />

1<br />

1. Albumin<br />

2. IgG<br />

1. Contaminant Peptides/Impurities<br />

2. RGAGGLGLGK-amide (883 Da)<br />

3. Ac-RGAGGLGLGK-amide (926 Da)<br />

4. Ac-RGVGGLGLGK-amide (954 Da)<br />

5. Ac-RGVVGLGLGK-amide (996 Da)<br />

2 3 4 5<br />

1<br />

2<br />

0 1 2 3 4 5 6 Min.<br />

Column: Vydac ® ProZap C18, 500Å, 1.5µm, 10 x 2.1mm<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.085% Trifluoroacetic Acid:n-Propanol (10:90)<br />

Gradient: Time: 0 6.0 6.5 7.0<br />

%B: 5 75 75 5<br />

Flow Rate: 0.5mL/min<br />

Detector: UV at 280nm<br />

0 0.2 0.4 0.6 0.8 1.0 Min.<br />

Column: Vydac ® ProZap C18, 500Å, 1.5µm, 10 x 2.1mm<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.085% Trifluoroacetic Acid:Acetonitrile (20:80)<br />

Gradient: Time: 0 0.1 0.7 1.1 1.2<br />

%B: 4 15 20 50 4<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 215nm<br />

438<br />

www.discoverysciences.com


hplc applications<br />

Purification of Trityl-On Oligonucleotides<br />

Proteins & Peptides/Reversed-Phase<br />

Human Growth Hormone<br />

Human Growth Hormone<br />

3<br />

1. di-Desamido HGH<br />

1. di-desamido HGH<br />

2. mono-Desamido 2. mono-desamido HGH HGH<br />

3. Human Growth 3. human Hormone growth (HGH) hormone (HGH)<br />

Purification of Trityl-On Oligonucleotides<br />

36-mer<br />

1<br />

2<br />

0 7 14 21 28 35 42 Min.<br />

Column: Vydac ® C4, 5µm, 250 x 4.6mm (Part No. 214TP54)<br />

Mobile Column: Phase: VYDAC Isopropanol:0.01M 214ATP54 (C4, 5 µm, Tris 4.6 mm buffer, i.d. pH7.5 x 250 mm) (29:71)<br />

Flow Eluent: Rate: 29% isopropanol/71% 1.0mL/min 0.01 M Tris buffer, pH 7.5<br />

Detector: UV<br />

Separation of Protein / Peptide Mixture<br />

on Vydac 219TP Diphenyl Column<br />

Separation of Protein / Peptide Mixture on<br />

Vydac ® 219TP Diphenyl Column<br />

1<br />

3<br />

2<br />

4<br />

2<br />

5<br />

2 6<br />

7<br />

8<br />

1. Horse Cytochrome C<br />

Tryptic Digest Fragments<br />

2. Whale Myoglobin CNBr<br />

Digest Fragments<br />

3. Ribonuclease<br />

4. Cytochrome<br />

5. Lysozyme<br />

6. BSA<br />

7. Myoglobin<br />

8. Ovalbumin<br />

0 5 10 15 20 Min.<br />

Column: Vydac ® C4, 5µm, 250 x 10mm (Part No. 214TP510)<br />

Mobile Phase: A: 0.1M Triethylammonium Acetate, pH7.0 B: Acetonitrile<br />

Gradient: Column: VYDAC Time: 214TP510 0 14(C4, 5 µm, 10 mm i.d. x 250 mm)<br />

Gradient: 16<br />

B%:<br />

to 23%<br />

16<br />

ACN<br />

23<br />

in 0.1 M triethylammonium acetate,<br />

pH 7.0, over 14 minutes<br />

Flow Comparison Rate: of 5.0mL/min<br />

Polypeptide Separations on<br />

Detector: C18, C4 and Diphenyl UV Reversed-Phase Columns<br />

218TP<br />

(C18)<br />

214TP<br />

(C4)<br />

219TP<br />

(diphenyl)<br />

Comparison of Polypeptide Separations on<br />

C18, C4 and Diphenyl Reversed-Phase Columns<br />

1<br />

1<br />

1<br />

2<br />

2<br />

2<br />

1. H<br />

2. TH6<br />

life science<br />

1. H<br />

2. TH6<br />

0 10 20 30 40 50 60 70 Min.<br />

Column: Vydac ® Diphenyl, 5µm, 250 x 4.6mm<br />

Columns: VYDAC (Part 219TP54 No. (diphenyl, 219TP54) 5 µm, 4.6 mm i.d. x 250 mm)<br />

Gradient: Mobile Phase: 0-70% A: ACN 0.1% with Trifluoroacetic 0.1% TFA in 67.5 Acid min<br />

Sample: 1. horse B: cytochrome Acetonitrilec tryptic digest fragments;<br />

Gradient: 2. whale Time: myoglobin 0 CNBr 67.5 digest fragments;<br />

3. ribonuclease; 4. cytochrome c; 5. lysozyme; 6. BSA;<br />

B%: 0 70<br />

IgG 7. Purification myoglobin; from and 8. Bovine ovalbumin Serum<br />

Flow Rate: 1.0mL/min<br />

Detector: UV<br />

IgG Purification from Bovine Serum<br />

2<br />

1. Serum Load Passthrough<br />

2. IgG 1. Serum Load Passthrough<br />

2. IgG<br />

0 5 10 15 20 25 30 Min.<br />

Column: Vydac ® C18, C4 and Diphenyl, all 5µm, 150 x 4.6mm<br />

(Part Nos. 218TP5415, 214TP5415, 219TP5415)<br />

Columns: Mobile Phase: VYDAC A: 218TP5415 0.1% Trifluoroacetic (C18), 214TP5415 Acid (C4) and<br />

219TP5415 B: Acetonitrile (diphenyl), all 5 µm, 4.6 mm i.d. x 150 mm<br />

Gradient: 10-90% ACN with 0.1% TFA over 30 min<br />

Gradient: Time: 0 30<br />

Sample: 18-residue helical peptide (1) and six-helix templateassembled<br />

B%: synthetic 10 90 protein (2)<br />

Sample: 18-Residue Helical Peptide (1) and<br />

Six-helix Template- assembled Synthetic Protein (2)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV<br />

Analysis of a Lipid Peptide<br />

Analysis of a Lipid Peptide<br />

1<br />

0 5 10 15 20 25 30 35 40 45 Min.<br />

0 10 20 30 40 50 60 Min.<br />

Column: Vydac ® Venture ® A RAVE Recombinant Protein A,<br />

Column: Vydac ® Diphenyl, 5µm, 250 x 4.6mm<br />

15-20µm, 50 x 4.6mm (Part No. 1520450)<br />

(Part No. 219TP54)<br />

Mobile Column: Phase: VENTURE A: 20mM A RAVE1520450<br />

Phosphate, pH7.4, 150mM Sodium Chloride Mobile Column: Phase: VYDAC A: 0.1% 219TP54 Trifluoroacetic (diphenyl, 5 µm, Acid 4.6 mm i.d. x 250 mm)<br />

(Recombinant Protein A, 15-20 µm, 4.6 mm i.d. x 50 mm)<br />

B: 0.1 M Sodium Citrate, pH3.2<br />

Flow: 1.5 mL/min<br />

B: n-Propanol:Acetonitrile:0.1% Trifluoroacetic Acid (50:50)<br />

Flow:<br />

1.38 mL/min (linear velocity = 500 cm/hr)<br />

Temp: 45 °C<br />

Gradient: Equilibrate with A for 3 min, load sample for 9 min,<br />

Gradient: Time: 0 45<br />

Eluent: A = 20 mM phosphate, pH 7.4, 150 mM NaCl<br />

Eluent: A = 0.1% TFA (v/v) in water<br />

B = 0.1 wash M sodium with A citrate, for 12 pH min, 3.2elute with B for 3 min,<br />

B = 50:50 %B: n-propanol:ACN, 25 70 0.1% TFA (v/v)<br />

Gradient: Equilibrate re-equilibrate with A for with 3 min, A for load 6 sample min for 9 min, wash<br />

Flow Gradient: Rate: 25 to 1.5mL/min<br />

70% B over 45 minutes<br />

Flow Rate: with 1.38mL/min A for 12 min, elute (linear with velocity B for 3 = min, 500cm/hr) re-equilibrate<br />

Detector: UV<br />

Detector: with UV A for at 6280nm<br />

min<br />

Detection: Absorbance, 280 nm<br />

more<br />

Sample:<br />

applications<br />

Commercial bovine serum diluted 1:20 with A and filtered<br />

View our complete through searchable a 0.45 chromatogram µm filter. Injection database volume at www.discoverysciences.com/chromdb/<br />

= 12.4 mL.<br />

ww.discoverysciences.com<br />

439


hplc applications<br />

Proteins & Peptides/Reversed-Phase<br />

Purification of Synthetic Peptide, GnRH Antagonist<br />

Separation of Xenotropic Murine Leukemia Virus from<br />

Target Protein<br />

life science<br />

0 10 20 30 40 50 60 Min.<br />

Column: Vydac ® C18 , 15–20µm, 50mm i.d. x 30cm<br />

(Part No. 218TP15205030)<br />

Mobile Phase: Acetonitrile:Water/TEAP (Gradient)<br />

Sample: 1.2g of synthesis mixture<br />

300 mAU<br />

200<br />

100<br />

Column:<br />

Mobile Phase:<br />

XMuLV Virus<br />

was detected<br />

in this peak<br />

Ethanol Gradient<br />

XMuLV Virus<br />

was below the<br />

limit of detection<br />

in this peak<br />

0 0 50 100 150 200mL<br />

Vydac ® C4 , 20-30µm (Part No. 214TPB2030)<br />

Ethanol gradient<br />

Preparative Chromatography of Porcine Insulin<br />

Analyses of Starting Material and Pooled<br />

Fractions from Preparative Column<br />

Analyses<br />

A 280<br />

A) 26mg<br />

Starting<br />

material<br />

6x scale<br />

Fraction Collection<br />

from Run C<br />

B) 41.5mg<br />

Fraction<br />

1<br />

Fractions<br />

2-16<br />

Fractions<br />

17-26<br />

Pure pool<br />

(fract 2 -16)<br />

6x scale<br />

C) 60mg<br />

0 25 50 75 100 Min.<br />

40 50 60 70 80 90 Min.<br />

Column:<br />

Vydac ® C4, 10-15µm, 10 x 250mm (Part No. 214TP101510)<br />

A) Sample: 26mg partially purified porcine insulin in 30mL of 20%<br />

Acetonitrile/0.1% Trifluoroacetic acid, pumped on at 8mL/min<br />

Elution: 4mL/min<br />

Gradient: 20-35% Acetonitrile in 0.1% Trifluoroacetic acid over 90 min<br />

B) Sample: 41.5mg in 42mL of 20% Acetonitrile/0.1% Trifluoroacetic<br />

acid, pumped on at 8mL/min<br />

Elution: 4mL/min<br />

Gradient: 20-27% Acetonitrile in 35 min, hold 27% for 10 min<br />

followed by 27-28% in 20 min, 28%-35% in 10 min, and<br />

35-95% in 5 min, all in 0.1% Trifluoroacetic acid.<br />

C) Sample: 60mg in 60mL of 20% Acetonitrile/0.1% Trifluoroacetic<br />

acid, pumped on at 8mL/min<br />

Elution: 4mL/min<br />

Gradient: 20-27% Acetonitrile in 35 min, hold 27% for 10 min<br />

followed by 27-28.5% in 30 min, hold 28.5% for 20 min<br />

Impure pool<br />

(fract 1 &<br />

17-26)<br />

6x scale<br />

0 5 10 15 Min.<br />

Column: Vydac ® C4, 5µm, 4.6 x 150mm<br />

(Part No. 214TP5415)<br />

Samples: Starting material and pooled fractions<br />

of preparative run C, as indicated.<br />

Detection: UV at 215nm<br />

Elution:<br />

1.5mL/min<br />

Gradient: 30-33% Acetonitrile in 0.1%<br />

Trifluoroacetic acid over 15 min<br />

440<br />

www.discoverysciences.com


hplc applications<br />

1) Cystine<br />

2) Cysteine<br />

3) Methionine<br />

Proteins & Peptides/Reversed-Phase<br />

Amino Acids<br />

mPEG-SBA<br />

1<br />

10636<br />

1. n-Hydroxysuccinimidyl Ester<br />

of Methoxy Poly(ethylene<br />

glycol) Butanoic Acid<br />

1<br />

2<br />

Sulfur-Containing Native Amino Sulfur-Containing Acids Native Amino Acids<br />

9413<br />

3<br />

1. Cystine<br />

Column 2. Cysteine phase: GROM-SIL 120 ODS-4 HE, 5 µ<br />

Column 3. Methionine size: 250 x 4 mm<br />

Eluent: water<br />

Flow rate: 0.8 ml/min<br />

Pressure: 12 MPa<br />

Temperature: RT<br />

Detection (UV): 210 nm<br />

Injection: 20 µl (50 ppm)<br />

life science<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Min.<br />

Column: Alltech ® ProSphere 300, 5µm, 150 x 4.6mm<br />

(Part No. 35560)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 3 15<br />

%B: 30 30 80<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 3 6 9 Min.<br />

Column: Grom Sil 120 ODS-4 HE, 5μm, 250 x 4mm<br />

(Part No. 5113626)<br />

Mobile Phase: Water<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 210nm<br />

1<br />

2<br />

3<br />

Thyroid Chemicals<br />

1. dl-Tyrosine<br />

2. 3-Iodo-Tyrosine<br />

3. 3,5- Diiodo-d-Tyrosine<br />

4 5<br />

8282<br />

4. dl-Thyroxine<br />

5. 3,3,5-Triiodo-l-Thyronine<br />

Phenylalanine Enantiomers<br />

O<br />

8770<br />

OH<br />

NH 2<br />

0 2 4 6 8 10 12 Min.<br />

Column: Alltech ® Platinum EPS C18, 5µm, 150 x 4.6mm<br />

(Part No. 32214)<br />

Mobile Phase: 0.05M KH2PO4, pH3.2:Acetonitrile (65:35)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

4 6 8 10 12 Min.<br />

Column: Astec Chirobiotic ® T, 250 x 4.6mm (Part No. 12053)<br />

Mobile Phase: Ethanol:Water (80:20)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 210nm<br />

Tryptophan Derivatives<br />

Tryptophan Derivatives<br />

1<br />

2<br />

3<br />

1. 5-Hydroxytryptophan<br />

2. 5-Hydroxytryptamine<br />

3. Tryptophan<br />

1<br />

4<br />

3<br />

2<br />

5<br />

6<br />

7<br />

Amino Acids without Derivatization<br />

8 9<br />

10<br />

11<br />

13<br />

12<br />

14<br />

16<br />

15<br />

17<br />

1. Gly<br />

2. Ser/Asn<br />

3. Asp<br />

4. Gln<br />

5. Ala/Thr<br />

6. Glu<br />

7. Cys/Lys<br />

8. His<br />

9. Pro<br />

10. Arg<br />

11. Val<br />

12. Met<br />

13. Tyr<br />

14. Ile<br />

15. Leu<br />

16. Phe<br />

17. Trp<br />

0 2 4 6 8 10 12 14 16 18 20 22 Min.<br />

0 5 10 15 20 25 Min.<br />

Column: Vydac ® C18, 5µm, 250 x 4.6mm (Part No. 201SP54) Column: Alltech ® Prevail C18, 5µm, 250 x 4.6mm (Part No. 99210)<br />

Mobile Column: Phase: VYDAC A: 201SP54 50mM KH2PO4, (C18, 5 µm, pH4.59 4.6 mm i.d. x 250mm)<br />

Mobile Phase: A: 5mM Heptafluorobutyric Acid, 0.7% Trifluoroacetic Acid<br />

Flow:<br />

1.5 mL/min B: 90% Acetonitrile<br />

B: Acetonitrile<br />

Gradient: Eluent: A = 50 Time: mM KH 2 PO 0 4 , pH 3 4.59 10 15<br />

Gradient: Time: 0 6 8 25<br />

B = 90% %B: ACN 1 1 15 35<br />

%B: 0 0 15 35<br />

Flow Gradient: Rate: Hold 1.5mL/min<br />

1% B for 3 min, then linear to 15% B over 7 min,<br />

Flow Rate: 1.0mL/min<br />

Detector:<br />

then linear<br />

UV at<br />

to<br />

254nm<br />

35% B over 5 min<br />

Detector: ELSD<br />

Detection: Absorbance, 254 nm<br />

Peaks: 1. 5-hydroxytryptophan, 2. 5-hydroxytryptamine,<br />

more applications<br />

3. tryptophan<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

441


hplc applications<br />

life science<br />

Nucleic Acids<br />

1<br />

2 3<br />

4<br />

5<br />

Nucleosides<br />

1. Cytidine<br />

2. Uridine<br />

3. Xanthosine<br />

4. Guanosine<br />

5. Adenosine<br />

0 2 4 6 8 10 12 Min.<br />

Column: Alltech ® Alltima HP EPS C18, 5µm, 150 x 4.6mm<br />

(Part No. 87715)<br />

Mobile Phase: A: 0.03M Potassium Phosphate, pH3.2<br />

B: Acetonitrile<br />

Gradient: Time: 0 2 20<br />

%B: 5 5 30<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 260nm<br />

10347<br />

1<br />

2<br />

Nucleosides<br />

0 5 10 15 20 Min.<br />

3<br />

4<br />

5<br />

1. Cytidine<br />

2. Uridine<br />

3. Xanthosine<br />

4. Guanosine<br />

5. Adenosine<br />

Column: Alltech ® Platinum EPS C18, 5µm, 250 x 4.6mm<br />

(Part No. 32246)<br />

Mobile Phase: A: 0.03M KH2PO4, pH3.2 B: Acetonitrile<br />

Gradient: Time: 0 2 20<br />

%B: 5 5 30<br />

Flow Rate: 0.7mL/min<br />

Detector: UV at 260nm<br />

8245<br />

Nucleosides<br />

9410<br />

1<br />

Nucleic Acid Bases<br />

9411<br />

1<br />

2<br />

5<br />

1. Cytidine<br />

2. Uridine<br />

3. Xanthosine<br />

4. Guanosine<br />

5. Adenosine<br />

2 3 4<br />

5<br />

1. Cytosine<br />

2. Uracil<br />

3. Guanine<br />

4. Adenine<br />

5. Thymine<br />

3<br />

4<br />

0 2 4 6 8 Min.<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208)<br />

Mobile Phase: 0.025M KH2PO4, pH3.0:Acetonitrile (96:4)<br />

Flow Rate: 1mL/min<br />

Detector: UV at 254<br />

0 2 4 6 8 Min.<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208)<br />

Mobile Phase: 0.025M KH2PO4, pH3.0:Acetonitrile (98:2)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254<br />

442<br />

www.discoverysciences.com


hplc applications<br />

Miscellaneous<br />

Phospholipids<br />

10314<br />

1<br />

2<br />

3<br />

4<br />

1. 1,2-Phosphatidyl-ethanolamine<br />

2. Phosphatidyl-dl-glycerol<br />

3. Phosphatidylinositol<br />

4. 1,2-Phosphatidyl-l-serine<br />

5. Phosphatidylcholine<br />

6. Sphingomyelin<br />

5 6<br />

Column: Alltech ® Prevail Silica, 3µm, 150 x 4.6mm (Part No. 99275)<br />

Mobile Phase: A: Isopropanol B: Hexane C: Water<br />

Gradient: Time: 0 7 15<br />

%B: 40 40 40<br />

%C: 2 8 8<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

life science<br />

0 3<br />

6 9 12 15 18 21 24 Min.<br />

Monoaromatics<br />

Aromatic Acids<br />

2<br />

3<br />

7<br />

4<br />

5 6<br />

9 10<br />

1. Uracil<br />

2. Benzamide<br />

3. Benzyl Alcohol<br />

4. Phenol<br />

5. Methylbenzoate<br />

6. Acetophenone<br />

7. N,N-Diethyl-m-toluamide<br />

8. Toluene<br />

9. Benzophenone<br />

10. Biphenyl<br />

8982<br />

1<br />

3<br />

2<br />

4 5<br />

1. dl-4-Hydroxy-3-methoxy-mandelic Acid<br />

2. Homovanillic Acid<br />

3. Vanillic Acid<br />

4. Salicylic Acid<br />

5. Benzoic Acid<br />

7373<br />

1<br />

8<br />

0 1<br />

2<br />

3<br />

4 Min.<br />

0 1 2 3 4 5 6 7 8 9 10 11 Min.<br />

Column: Alltech ® Platinum EPS C18, 3µm, 53 x 7mm Rocket<br />

(Part No. 50573)<br />

Mobile Phase: 0.05M KH2PO4, pH3.0:Methanol (50:50)<br />

Flow Rate: 2.3mL/min<br />

Detector: UV at 254nm<br />

Column: Alltech ® Alltima C18, 5µm, 150 x 4.6mm (Part No. 88052)<br />

Mobile Phase: 0.05M KH2PO4, pH3.2:Methanol (60:40)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

1<br />

2 3<br />

4<br />

Benzyl Acids<br />

5<br />

9538<br />

1. 3-Amino-4-hydroxybenzoic Acid<br />

2. 4-Hydroxybenzoic Acid<br />

3. Benzoic Acid<br />

4. 4-Phenylbutyric Acid<br />

5. 5-Phenylbutyric Acid<br />

1<br />

2 3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

10<br />

9<br />

11<br />

Alcohols<br />

12<br />

1. Glycerol<br />

2. Methanol<br />

3. Ethanol<br />

4. Isopropanol<br />

5. tert-Butanol<br />

6. Propanol<br />

7. sec-Butanol<br />

8. Isobutanol<br />

9. tert-Pentanol<br />

10. Butanol<br />

11. Isopentanol<br />

12. Pentanol<br />

5440<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: Alltech ® Prevail Organic Acid, 5µm, 150 x 4.6mm<br />

(Part No. 88640)<br />

Mobile Phase: 0.025M KH2PO4, pH2.5:Acetonitrile (60:40)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

0 4 8 12 16 20 24 28 Min.<br />

Column: Alltech ® OA-1000, 9µm, 300 x 6.5mm (Part No. 9046)<br />

Mobile Phase: 0.01N Sulfuric Acid<br />

Flow Rate: 0.8ml/min<br />

Column Temp: 65°C<br />

Detector: RI<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

443


hplc applications<br />

Pesticides<br />

1<br />

Organophosphates<br />

3<br />

10346<br />

1. Methyl Parathion<br />

2. Dichlorvos<br />

3. Ethoprophos<br />

4. Azinphos<br />

1<br />

Organochlorines<br />

1. Methoxychlor<br />

2. Dieldrin<br />

3. Heptachlor<br />

4. 4,4-DDT<br />

8437<br />

environmental<br />

0 4<br />

2<br />

8 12 16 20 24 Min.<br />

Column: Alltech ® Alltima HP EPS C18, 5µm, 150 x 4.6mm<br />

(Part No. 87715)<br />

Mobile Phase: Water:Methanol (60:40)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 214nm<br />

4<br />

0 3<br />

2<br />

3<br />

6 9 12 Min.<br />

Column: Alltech ® Platinum C18, 5µm, 150 x 4.6mm<br />

(Part No. 32043)<br />

Mobile Phase: 0.025M K2HPO4, pH7.0:Methanol (25:75)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 220nm<br />

4<br />

1<br />

2<br />

3<br />

Triazine Herbicides<br />

4 5<br />

6<br />

7<br />

1. Simazine<br />

2. Simetryn<br />

3. Prometon<br />

4. Atrazine<br />

5. Ametryn<br />

6. Prometryn<br />

7. Terbutryn<br />

8671<br />

1<br />

2<br />

3<br />

Herbicides<br />

4<br />

1. Fenuron<br />

2. Monuron<br />

3. Diuron<br />

4. Linuron<br />

10355<br />

0 1 2 3 4 5 Min.<br />

Column: Alltech ® Platinum EPS C18,<br />

1.5µm, 33 x 7mm Rocket (Part No. 50575)<br />

Mobile Phase: 0.025M KH2PO4, pH3.0:Acetonitrile (65:35)<br />

Flow Rate: 2.0mL/min<br />

Detector: UV at 254nm<br />

0<br />

1 2 3 4 5 6 7 8 Min.<br />

Column: Alltech ® Alltima HP CN, 5µm, 150 x 4.6mm<br />

(Part No. 87769)<br />

Mobile Phase: Water:Acetonitrile (60:40)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Carbamate and Urea Pesticides<br />

10739<br />

1<br />

Bipyridylium Herbicides<br />

8439<br />

1<br />

2<br />

4<br />

3<br />

5<br />

6<br />

7<br />

1. Fenuron<br />

2. Monuron<br />

3. Fluometuron<br />

4. Diuron<br />

5. Methiocarb<br />

6. Linuron<br />

7. Neburon<br />

2<br />

1. Diquat<br />

2. Paraquat<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 150 x 4.6mm<br />

(Part No. 5138812)<br />

Mobile Phase: A: 0.025M KH2PO4, pH3.2<br />

B: Acetonitrile<br />

Gradient: Time: 0 20<br />

%B: 30 60<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 240nm<br />

0 2<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

4 6 8 Min.<br />

Alltech ® Platinum Silica 100Å 3µm,<br />

30mm x 4.6mm (Custom)<br />

0.01M Tetramethylammonium Hydroxide and<br />

0.15M Ammonium Sulfate in Water, pH3.0 with<br />

5M Sulfuric Acid<br />

0.5mL/min<br />

UV at 310nm until 3 minutes<br />

UV at 260nm after 3 minutes<br />

444<br />

www.discoverysciences.com


hplc applications<br />

1<br />

Organochlorine Pesticides<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 150 x 4.6mm<br />

(Part No. 5138812)<br />

Mobile Phase: Methanol:0.025M K2HPO4, pH7.0 (75:25)<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 220nm<br />

2<br />

10740<br />

1. Methoxychlor<br />

2. 4,4-DDT<br />

1<br />

2<br />

3 4 5<br />

Triazine Pesticides<br />

6 7 89<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

Column: Vydac ® Denali ® 238DE C18, 3µm, 100 x 4.6mm<br />

(Part No. 238DE3410)<br />

Mobile Phase: A: 25mM Potassium Phosphate, pH6.4<br />

B: Acetonitrile<br />

Gradient: Time: 0 0.5 7.5 8.0<br />

%B: 40 40 63 63<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 220nm<br />

10580<br />

1. Simazine<br />

2. Atraton<br />

3. Simetryn<br />

4. Atrazine<br />

5. Prometon<br />

6. Ametryn<br />

7. Propazine<br />

8. Prometryn<br />

9. Terbutryn<br />

environmental<br />

2<br />

1<br />

3<br />

Analysis of Pesticides<br />

5<br />

4 6<br />

78 9<br />

12 14<br />

13<br />

15<br />

11<br />

10<br />

0 3 6 9 12 Min.<br />

1. Methomyl<br />

2. Oxamyl<br />

3. Fenurone<br />

4. Monurone<br />

5. Carburone<br />

6. Propoxur<br />

7. Carbaryl<br />

8. Fluometurone<br />

9. Diurone<br />

10. Propham<br />

11. Sidurone<br />

12. Linurone<br />

13. Chlorpropham<br />

14. Barban<br />

15. Neburone<br />

1<br />

2<br />

3<br />

Atrazine Herbicides<br />

Atrazine Herbicides<br />

0 2 4 6 8 10 Min.<br />

4<br />

1. Atazine Desisopropyl<br />

2. Atrazine Desethyl<br />

3. Simazine<br />

4. Propazine<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Grom Sil 100 Octyl-4 FE, 3μm, 150 x 4mm<br />

A: Water B: Acetonitrile<br />

1.5mL/min<br />

UV at 240nm<br />

Column: GENESIS Jones FM15965E Genesis (CN, ® CN, 4 µm, 4μm, 4.6150 mm i.d. x 4.6mm x 150 mm)<br />

Flow:<br />

1.0 mL/min<br />

(Part No. FM15965E)<br />

Eluent: Isocratic, 15% ACN/0.05% TCA in water (pH 3.0)<br />

Detection:<br />

Mobile Phase:<br />

Absorbance,<br />

Acetonitrile:0.05%<br />

254 nm<br />

Trichloroacetic Acid in Water, pH3.0<br />

Peaks: 1. Atazine (15:85) desisopropyl, 2. Atrazine desethyl, 3. Simazine,<br />

Flow Rate: 4. Propazine 1.0mL/min<br />

Detector: UV at 254nm<br />

Separation of Chlorophenoxyacid Herbicide Mixtures<br />

Separation of Chlorophenoxy Acid Herbicide Mixtures<br />

1<br />

Benzenes<br />

Benzenes<br />

10713<br />

2<br />

3 4 8<br />

5 6 7<br />

1. picloram<br />

2. chloramben<br />

3. dicamba<br />

4. bentazon<br />

5. 2,4-D<br />

6. dichlorprop<br />

7. 2,4,5-TP<br />

8. acifluorphen<br />

1. Picloram<br />

2. Chloramben<br />

3. Dicamba<br />

4. Bentazon<br />

5. 2,4-D<br />

6. Dichlorprop<br />

7. 2,4,5-TP<br />

8. Acifluorphen<br />

1<br />

2<br />

3<br />

4<br />

1. Thiourea<br />

2. Toluene<br />

3. Propylbenzene<br />

4. Butylbenzene<br />

0 1 2 3 4 5 Min.<br />

0 0.5 1 1.5 2 Min.<br />

Column: Vydac ® Denali ® , 3μm, 100 x 4mm (Part No. 238DE3410) Column: <strong>Grace</strong> ® VisionHT C18, 1.5µm, 50 x 2.0mm<br />

Mobile Phase: A: 0.5% Phosphoric Acid Buffer, pH1.8; B: Acetonitrile<br />

(Part No. 5139605)<br />

Gradient: Column: DENALI Time: 238DE3410 0 5(3 µm, 4.6 mm i.d. x 100 mm)<br />

Mobile Phase: 20mM Potassium Phosphate, pH2.5:Acetonitrile (45:55)<br />

Flow:<br />

1.0 mL/min<br />

%B: 50 90<br />

Flow Rate: 0.8mL/min<br />

Mixture A Eluent: A = 0.5% phosphoric acid buffer, pH 1.8; B = ACN<br />

Flow Rate:<br />

Gradient:<br />

1.0mL/min<br />

50 to 90% B over 5 min<br />

Detector: UV at 254nm<br />

Detector:<br />

Temp: 23 °CUV at 225nm<br />

Detection: Absorbance, 225 nm<br />

more Samples: applications 2 µL herbicide mixtures, 0.3 µg/mL each compound<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

445


hplc applications<br />

PAHs<br />

Polyaromatic Hydrocarbons<br />

9400<br />

environmental<br />

4 6 11 7<br />

12<br />

5<br />

14<br />

16<br />

13<br />

8<br />

9<br />

1 3<br />

15<br />

17<br />

2<br />

10<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

1. Benzene<br />

2. Naphthalene<br />

3. Acenaphthylene<br />

4. Fluorene<br />

5. Acenaphthene<br />

6. Phenanthrene<br />

7. Anthracene<br />

8. Fluoranthene<br />

9. Pyrene<br />

10. Benz[a]anthracene<br />

11. Chrysene<br />

12. Benzo[b]fluoranthene<br />

13. Benzo[k]fluoranthene<br />

14. Benzo[a]pyrene<br />

15. Dibenz[a,h]anthracene<br />

16. Benzo[g,h,i]perylene<br />

17. Indeno[1,2,3,c,d]pyrene<br />

Column: Alltech ® Prevail C18, 5µm, 150 x 4.6mm (Part No. 99208)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 4 15<br />

%B: 72 72 100<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 254<br />

Beyond the EPA 16 Priority-Pollutant PAHs<br />

1<br />

2<br />

3 4 5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

18<br />

1112 13 1415 16 17<br />

19<br />

20<br />

23<br />

22<br />

21<br />

0 4 8 12 16 20 24 28 32 Min.<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. 1-Methylnaphthalene<br />

4. 2-Methylnaphthalene<br />

5. Acenaphthene<br />

6. Fluorene<br />

7. Phenanthrene<br />

8. Anthracene<br />

9. Fluoranthene<br />

10. Pyrene<br />

11. Benzo[c]phenanthrene<br />

12. Cyclopenta[c,d]pyrene<br />

13. Benz[a]anthracene<br />

14. Chrysene<br />

15. Benzo[b]naptho[2,1-d]thiopen<br />

16. 7,12-Dimethylbenz[a]anthracene<br />

17. Benzo[e]pyrene<br />

18. Benzo[b]fluoranthene<br />

19. Benzo[k]fluoranthene<br />

20. Benz[a]pyrene<br />

21. Dibenz[a,h]anthracene<br />

22. Benzo[g,h,i]perylene<br />

23. Indeno[1,2,3,c,d]pyrene<br />

Column: Vydac ® C18, 5µm, 150 x 4.6mm (Part No. 201TP5415)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 30<br />

%B: 50 100<br />

Flow Rate: 1.0mL/min<br />

1. Naphthalene<br />

2. Acenapthylene<br />

3. Acenaphthene<br />

4. Fluorene<br />

5. Phenanthrene<br />

6. Anthracene<br />

12 3<br />

4<br />

5<br />

Fast Polyaromatic Hydrocarbons<br />

7. Fluoranthene<br />

8. Pyrene<br />

9. Benzo[a]anthracene<br />

10. Chrysene<br />

11. Benzo[b]fluoranthene<br />

12. Benzo[k]fluoranthene<br />

6<br />

7 8<br />

9<br />

10<br />

11<br />

13 16<br />

12 15<br />

14<br />

10757<br />

13. Benzo[a]pyrene<br />

14. Dibenzo[a,h]anthracene<br />

15. Benzo[g,h,i]perylene<br />

16. Indeno[1,2,3,c,d]pyrene<br />

0 1 2 3 4 5 6 Min.<br />

Column: Alltech ® Alltima HP C18 HiLoad, 3µm, 53 x 7mm<br />

(Part No. 87690)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 0.1 5<br />

%B: 40 40 100<br />

Flow Rate: 5mL/min<br />

Detector: UV at 230nm<br />

0<br />

Nitroaromatics<br />

1<br />

Nitroaromatics (Normal-Phase)<br />

2<br />

3<br />

4<br />

1 2 3 4 5 6 7 8 Min.<br />

Column: Alltech ® Alltima HP CN, 5µm, 150 x 4.6mm<br />

(Part No. 87769)<br />

Mobile Phase: Hexane:Isopropanol (85:15)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

10358<br />

1. Nitrobenzene<br />

2. 2,6-Dinitrotoluene<br />

3. 1,3-Dinitrobenzene<br />

4. 4-Nitrophenol<br />

446<br />

www.discoverysciences.com


hplc applications<br />

Water Pollutants<br />

Semipolar & Highly Hydrophilic Waste Water Contaminants<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6 7 8<br />

9<br />

10<br />

1112<br />

13<br />

14<br />

16<br />

15 17<br />

10 20 30 40 50 Min.<br />

Column: Alltech ® Platinum EPS C18, 5µm, 250 x 4.6mm<br />

(Part No. 32246)<br />

Mobile Phase: A: 0.03M Monosodium Phosphate, pH2.5<br />

B: Acetonitrile:Methanol:Water (40:50:10)<br />

Gradient: Time: 0 3 13 20 25 30 40 45 55<br />

%B: 5 5 10 10 20 40 75 80 80<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 210nm<br />

18<br />

19<br />

8447<br />

1. 4-Amino-5-hydroxy-2,7-naphthalene-disulfonic Acid<br />

2. Hydroquinone<br />

3. Benzylamine<br />

4. 3'-Aminoacetophenone<br />

5. Phenol<br />

6. 4-Hydroxyphenylacetic Acid<br />

7. 1-Naphthalene Sulfonic Acid<br />

8. 2,4-Dihydroxybenzoic Acid<br />

9. 1-Naphthalene Sulfonic Acid Degradant<br />

10. 4-Hydroxy-3-methoxybenzoic Acid<br />

11. Phenylacetic Acid<br />

12. m-Cresol<br />

13. 4-Hydroxycinnamic Acid<br />

14. trans-Cinnamaldehyde<br />

15. trans-Cinnamaldehyde Degradant<br />

16. trans-Cinnamaldehyde Degradant<br />

17. 2-Naphthalenethiol Degradant<br />

18. 2-Naphthalenethiol<br />

19. 2-Naphthalenethiol Degradant<br />

environmental<br />

Explosives<br />

Nitroaromatic and Nitroamine Explosives<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

1. HMX<br />

2. RDX<br />

3. TNB<br />

4. DNB<br />

5. Tetryl<br />

6. NB<br />

7. TNT<br />

8. 4-A-DNT<br />

9. 2,6DNT<br />

10. 2,4DNT<br />

11. 2-NT<br />

12. 3-NT<br />

13. 4-NT<br />

8 9 10 11 12<br />

13<br />

8279<br />

1. HMX<br />

2. RDX<br />

3. 1,3,5-TNB<br />

1 2<br />

3<br />

Explosive Analysis, EPA Method 8330<br />

4<br />

5<br />

4. 1,3-DNB<br />

5. Tetryl<br />

6. Nitrobenzene (NB)<br />

7. 2,4,6-TNT<br />

6<br />

7<br />

8 9 1011<br />

12 13 14<br />

10511<br />

8. 4-Amino-2,6-Dinitrotoluene<br />

(4-AM-DNT)<br />

9. 2-Amino-4,6-Dinitrotoluene<br />

(2-Am-DNT)<br />

10. 2,6-DNT<br />

11. 2,4-DNT<br />

12. 2-NT<br />

13. 4-NT<br />

14. 3-NT<br />

0 2 4 6 8 10 12 14 16 18 20 22 Min.<br />

Column: Alltech ® Platinum C18, 5µm, 250 x 4.6mm<br />

(Part No. 32064)<br />

Mobile Phase: Water:Methanol (50:50)<br />

Flow Rate: 0.7mL/min<br />

Detector: UV at 254nm<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Alltech ® Adsorbosphere UHS C18, 5µm, 150 x 4.6mm<br />

(Part No. 288118)<br />

Mobile Phase: Water:Methanol (50:50)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Phenols<br />

1<br />

2<br />

Phenols<br />

3 4 5<br />

10707<br />

1. Phenol<br />

2. 4-Nitrophenol<br />

3. 2-Chlorophenol<br />

4. 2-Nitrophenol<br />

5. 2,4-Dichlorophenol<br />

Separation of EPA 604 Phenols Mixture<br />

1<br />

2<br />

3<br />

4<br />

7<br />

5<br />

6 8<br />

9<br />

10 11<br />

1. Phenol<br />

2. 4-Nitrophenol<br />

3. 2-Chlorophenol<br />

4. 2-Nitrophenol<br />

5. 2,4-Dinitrophenol<br />

6. 2,4-Dimethylphenol<br />

7. 4-Chloro-3-Methylphenol<br />

8. 2,4-Dichlorophenol<br />

9. 2-Methyl-4,6-Dinitrophenol<br />

10. 2,4,6-Trichlorophenol<br />

11. Pentachlorophenol<br />

0 2 4 6 8 10 12 14 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm<br />

(Part No. 5138810)<br />

Mobile Phase: A: 1% Glacial Acetic Acid in Water<br />

B: 1% Glacial Acetic Acid in Methanol<br />

Gradient: Time: 0 6 8 15<br />

%B: 45 45 60 80<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 280nm<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 Min.<br />

Column: Vydac ® Denali ® , 5µm, 150 x 4.6mm (Part No. 238DE5415)<br />

Mobile Phase: A: 1% Acetic Acid in Water<br />

B: 1% Acetic Acid in Acetonitrile<br />

Gradient: Time: 0 7 8 13<br />

%B: 35 63 95 95<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 280nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

447


hplc applications<br />

Fullerenes<br />

“Bucky Balls”<br />

Buckminsterfullerenes<br />

2<br />

7210<br />

Buckminsterfullerenes<br />

1. C70<br />

2. C60<br />

1<br />

C 60 C 70<br />

C 76 C84<br />

miscellaneous<br />

0 30 60 90 120 150 180 Min.<br />

0 5 10 15 20 Min.<br />

Column: Jordi DVB, 500Å, 500 x 10mm (6) (Part No. 100567) 1) trans-1-C62(COOEt)4<br />

Column: Vydac ® C4, 5μm, 250 x 10mm (Part No. 201TP510)<br />

Mobile Phase: Trichlorobenzene<br />

2) trans-2-C62(COOEt)4<br />

Mobile Column: Phase: VYDAC Acetonitrile:Toluene 201TP510 (C4, 5 µm, (50:50) 10 mm i.d. x 250 mm)<br />

Flow Rate: 1.5mL/min<br />

3) trans-3-C62(COOEt)4<br />

Flow Eluent: Rate: Isocratic, 5mL/min 1:1 ACN/toluene<br />

Column Temp: 145°C<br />

Flow: 5 mL/min<br />

4) trans-4-C62(COOEt)4<br />

Detector: RI<br />

5) e-C62(COOEt)4<br />

Cooking Oil<br />

Regioisomeric Fullerene Derivatives Regioisomeric Fullerene Derivatives<br />

5 Used Cooking Oil<br />

7215<br />

1<br />

2<br />

3<br />

4<br />

5<br />

1. trans-1-C62(COOEt)4<br />

2. trans-2-C62(COOEt)4<br />

3. trans-3-C62(COOEt)4<br />

4. trans-4-C62(COOEt)4<br />

5. e-C62(COOEt)4<br />

Column phase: GROM-SIL 100 Norm Ph-1 ST, 5 µm<br />

Column size: 250 x 4 mm<br />

Eluent: toluene<br />

Flow rate: 1.5 ml/min<br />

Pressure: 12 MPa<br />

Temperature: RT<br />

Detection (UV): 340 nm, 0.084<br />

6<br />

AUFS<br />

Injection: 5 µl (50 µg/ml) 3<br />

1 2 7 8<br />

1. Polymerized<br />

2. Polymerized<br />

3. Triglycerides<br />

4. MW 1800-3000<br />

5. Triglycerides MW 930<br />

6. Diglycerides MW 620<br />

7. Monoglycerides MW 400<br />

8. Free Fatty Acids MW 300<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

Column: Grom Sil 100 Norm Ph-1 ST, 5μm, 250 x 4mm<br />

Mobile Phase: Toluene<br />

Flow Rate: 1.5mL/min<br />

Detector: UV at 340nm<br />

0 10 20 30 40 Min.<br />

Column: Jordi DVB, 10 3 Å, 500Å, 500mm x 10mm (2)<br />

(Part No.s 100571, 100567)<br />

Mobile Phase: Tetrahydrofuran<br />

Flow Rate: 2.0mL/min<br />

Detector: UV at 254nm<br />

Surfactants<br />

Microbore Analysis of Glucopyranosides<br />

1. n-octyl Glucopyranoside (50ng on column)<br />

2. n-decyl Glucopyranoside (50ng on column)<br />

3. n-dodecyl Glucopyranoside (50ng on column)<br />

10310<br />

1<br />

2<br />

3<br />

0 1<br />

2<br />

3<br />

4 5 6 7 8 Min.<br />

Column: Alltech ® Alltima C18, 5µm, 150 x 1mm (Part No. 88384)<br />

Mobile Phase: Methanol:Water (90:10)<br />

Flow Rate: 0.05mL/min<br />

Detector: ELSD<br />

448<br />

www.discoverysciences.com


hplc applications<br />

Polymers<br />

Polyurethane Curatives<br />

7472<br />

Polystyrene<br />

7213<br />

1<br />

2<br />

1. Polytetramethylene Glycol<br />

2. Ethecure 300<br />

1<br />

2 3 4 5 6 7<br />

8<br />

9<br />

10<br />

1. 8.42M<br />

2. 1.3M<br />

3. 791K<br />

4. 354K<br />

5. 98.9K<br />

6. 43K<br />

7. 10.1K<br />

8. 2.6K<br />

9. 530K<br />

10. 120K<br />

70 100 130 160 Min.<br />

Column: Jordi DVB, 500Å, 500mm x 10mm (6)<br />

(Part No. 100567)<br />

Mobile Phase: Chloroform<br />

Flow Rate: 1.5mL/min<br />

Column Temp: 50°C<br />

Detector: RI<br />

0 5 10 15 20 25 30 Min.<br />

Column: Jordi DVB, Mixed Bed Linear, 500mm x 10mm<br />

(Part No. 100583)<br />

Mobile Phase: Tetrahydrofuran<br />

Flow Rate: 1.5mL/min<br />

Column Temp: 40°C<br />

Detector: RI<br />

miscellaneous<br />

1<br />

2<br />

9<br />

8<br />

3 4 567<br />

10 1112 13<br />

14 15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

2122<br />

Polyethylene and Hydrocarbon Standards<br />

2425<br />

23<br />

26 2728 29<br />

0 30 60 90 120 150 180 Min.<br />

30<br />

31<br />

32<br />

1. PE-32000 MW<br />

2. PE-2155 MW<br />

3. C58<br />

4. C56<br />

5. C54<br />

6. C52<br />

7. C50<br />

8. C48<br />

9. C46<br />

10. C44<br />

11. C42<br />

12. C40<br />

13. C38<br />

14. C36<br />

15. C34<br />

16. C32<br />

17. C30<br />

18. C28<br />

19. C26<br />

20. C24<br />

21. C22<br />

22. C20<br />

23. C18<br />

24. C16<br />

25. C14<br />

26. C12<br />

27. C10<br />

28. C9<br />

29. C8<br />

30. C7<br />

31. C6<br />

32. C5<br />

7220<br />

Column: Jordi DVB, 500Å, 500mm x 10mm (6)<br />

(Part No. 100567)<br />

Mobile Phase: Trichlorobenzene<br />

Flow Rate: 1.5mL/min<br />

Column Temp: 145°C<br />

Detector: RI<br />

Tween 80<br />

Dimethicone<br />

7809<br />

8636<br />

0 5 10 15 20 25 30 Min. 0 4 8 12 16 20 Min.<br />

Column: Alltech ® Alltima C18, 5µm, 250 x 4.6mm<br />

(Part No. 88056)<br />

Mobile Phase: Water:Methanol (40:60)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Column: Alltech ® Alltima C8, 5µm, 150 x 4.6mm (Part No. 88072)<br />

Mobile Phase: A: Acetonitrile B: Chloroform<br />

Gradient: Time: 0 20<br />

%B: 25 75<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

449


hplc applications<br />

Polymers<br />

Polyethylene Glycol (MW=600)<br />

8442<br />

Phenones/Fast Gradient Column Formats<br />

1<br />

2 3<br />

Phenone Homologs<br />

4 5<br />

7<br />

6<br />

8<br />

9<br />

9467<br />

1. Uracil<br />

2. Theophylline<br />

3. Acetophenone<br />

4. Propiophenone<br />

5. Butyrophenone<br />

6. Benzophenone<br />

7. Valerophenone<br />

8. Heptanophenone<br />

9. Octanophenone<br />

miscellaneous<br />

0 5 10 15 20 25 30 35 Min.<br />

Column: Alltech ® Adsorbosphere C8, 5µm, 250 x 4.6mm<br />

(Part No. 287112)<br />

Mobile Phase: A: Methanol B: Water<br />

Gradient: Time: 0 45<br />

%B: 60 20<br />

Flow Rate: 0.6mL/min<br />

Detector: ELSD<br />

1<br />

2 3<br />

4 5<br />

6<br />

0 1 2 3 Min.<br />

Columns: Alltech ® Alltima C18, 3µm, 10 x 2.1mm Expedite<br />

(Part No. 43836)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.08% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 2<br />

%B: 5 100<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

1<br />

2<br />

Phenone Homologs<br />

3<br />

7<br />

4 5<br />

8<br />

9<br />

Phenone Homologs<br />

6<br />

7<br />

8<br />

9<br />

9471<br />

1. Uracil<br />

2. Theophylline<br />

3. Acetophenone<br />

4. Propiophenone<br />

5. Butyrophenone<br />

6. Benzophenone<br />

7. Valerophenone<br />

8. Heptanophenone<br />

9. Octanophenone<br />

9460<br />

1. Uracil<br />

2. Theophylline<br />

3. Acetophenone<br />

4. Propiophenone<br />

5. Butyrophenone<br />

6. Benzophenone<br />

7. Valerophenone<br />

8. Heptanophenone<br />

9. Octanophenone<br />

0 1 2 3 Min.<br />

Columns: Alltech ® Alltima C18, 3µm, 20 x 4.6mm Expedite<br />

(Part No. 43451)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.08% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 2<br />

%B: 5 100<br />

Flow Rate: 2.0mL/min<br />

Detector: UV at 254nm<br />

0 1 2 3 Min.<br />

Columns: Alltech ® Alltima C18, 3µm, 10 x 4.6mm Expedite<br />

(Part No. 43837)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.08% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 2<br />

%B: 5 100<br />

Flow Rate: 2.0mL/min<br />

Detector: UV at 254nm<br />

1<br />

1<br />

2<br />

2 3<br />

Phenone Homologs<br />

4 5<br />

7<br />

6<br />

3<br />

4 5<br />

8 9<br />

Phenone Homologs<br />

6<br />

7<br />

8<br />

9<br />

9468<br />

1. Uracil<br />

2. Theophylline<br />

3. Acetophenone<br />

4. Propiophenone<br />

5. Butyrophenone<br />

6. Benzophenone<br />

7. Valerophenone<br />

8. Heptanophenone<br />

9. Octanophenone<br />

9462<br />

1. Uracil<br />

2. Theophylline<br />

3. Acetophenone<br />

4. Propiophenone<br />

5. Butyrophenone<br />

6. Benzophenone<br />

7. Valerophenone<br />

8. Heptanophenone<br />

9. Octanophenone<br />

0 1 2 3 Min.<br />

Column: Alltech ® Prevail C18, 3µm, 20 x 2.1mm, Expedite<br />

(Part No. 43827)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.08% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 2 3<br />

%B: 0 100 100<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

0 1 2 3 Min.<br />

Column: Alltech ® Alltima C18, 3µm, 20 x 2.1mm Expedite<br />

(Part No. 43803)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid in Water<br />

B: 0.08% Trifluoroacetic Acid in Acetonitrile<br />

Gradient: Time: 0 2<br />

%B: 5 100<br />

Flow Rate: 1.2mL/min<br />

Detector: UV at 254nm<br />

450<br />

www.discoverysciences.com


hplc applications<br />

Biofuels<br />

Triacylglycerols in Canola Oil<br />

6<br />

10749<br />

Triacylglycerols in Red Palm Oil<br />

7 8<br />

10750<br />

1<br />

2<br />

3 4 5<br />

0 5 10 15 20 25 Min.<br />

1. LLnLn<br />

2. LLLn<br />

3. OLnL<br />

4. LLO<br />

5. LOO<br />

6. PLO<br />

7. OOO<br />

8. POO<br />

9. POP<br />

10. PPP<br />

Column: Alltech ® Alltima HP C18 HiLoad, 5µm, 250 x 4.6mm<br />

(Part No. 87698)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 20 25 30 35<br />

%B: 30 70 70 30 30<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

6<br />

5<br />

4<br />

1 2 3<br />

0 5 10 15 20 25 Min.<br />

9<br />

10<br />

11<br />

12 13<br />

1. PLL<br />

2. LOO<br />

3. PLO<br />

4. PLP<br />

5. MOP<br />

6. OOO<br />

7. POO<br />

8. POP<br />

9. SOO<br />

10. PPP<br />

11. POS<br />

12. PPS<br />

13. SOS<br />

Column: Alltech ® Alltima HP C18 HiLoad, 5µm, 250 x 4.6mm<br />

(Part No. 87698)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 20 25 30 35<br />

%B: 30 70 70 30 30<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

miscellaneous<br />

4 6 7 9<br />

1. Mono-acylglycerol<br />

(MAG)<br />

2. MAG<br />

3. MAG<br />

8<br />

3<br />

11<br />

5<br />

1 2 10<br />

0 5 10 15 20 25 30 Min.<br />

Triacylglycerols in Used Chinese Frying Oil<br />

3<br />

10751<br />

6<br />

3<br />

1<br />

2<br />

7<br />

8<br />

10<br />

4<br />

9<br />

5<br />

7 8 9 10<br />

451<br />

Biodiesel in Spec with EN14105 Method<br />

4. Fatty Acid Methyl Ester<br />

(FAME)<br />

5. MAG<br />

6. FAME<br />

7. FAME<br />

8. MAG<br />

9. FAME<br />

10. Di-acylglycerol (DAG)<br />

11. Tri-acylglycerol (TAG)<br />

10644<br />

Column: Alltech ® Alltima HP C18 HiLoad, 5µm, 250 x 4.6mm<br />

(Part No. 87698)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 5 30 32 35<br />

%B: 0 15 70 70 0<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Triacylglycerols in Soy Oil<br />

10748<br />

11 12 13 14<br />

15<br />

1. LLnLn<br />

2. LLLn<br />

3. LLL<br />

4. OLLn<br />

5. PLLn<br />

6. LLO<br />

7. PLL<br />

8. LOO<br />

9. LLS<br />

10. PLO<br />

11. PLP<br />

12. OOO<br />

13. SLO<br />

14. POO<br />

15. POP<br />

6<br />

7<br />

2 10 9<br />

8<br />

4<br />

12<br />

11 13<br />

5 14<br />

1 15<br />

1. LLnLn<br />

2. LLLn<br />

3. LLL<br />

4. OLLn<br />

5. PLLn<br />

6. LLO<br />

7. PLL<br />

8. LLO<br />

9. LLS<br />

10. PLO<br />

11. PLP<br />

12. OOO<br />

13. SLO<br />

14. POO<br />

15. POP<br />

0 5 10 15 20 25 Min.<br />

Column: Alltech ® Alltima HP C18 HiLoad, 5µm, 250 x 4.6mm<br />

(Part No. 87698)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 20 25 30 35<br />

%B: 30 70 70 30 30<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 5 10 15 20 25 Min.<br />

Column: Alltech ® Alltima HP C18 HiLoad, 5µm, 250 x 4.6mm<br />

(Part No. 87698)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 20 25 30 35<br />

%B: 30 70 70 30 30<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com


hplc applications<br />

Biofuels<br />

Triacylglycerols in Lard<br />

2<br />

10752<br />

Fire Retardants<br />

Brominated Flame Retardants<br />

10261<br />

1<br />

3<br />

1. PPO<br />

2. PPP<br />

3. POS<br />

4. SSS<br />

1 2<br />

1. Hexabromo<br />

Cyclododecane<br />

2. Tetrabromo<br />

Bisphenol A (Allyl Ether)<br />

miscellaneous<br />

4<br />

0 5 10 15 20 25 Min.<br />

Column: Alltech ® Alltima HP C18 HiLoad, 5µm, 250 x 4.6mm<br />

(Part No. 87698)<br />

Mobile Phase: A: Acetonitrile B: Dichloromethane<br />

Gradient: Time: 0 20 25 30 35<br />

%B: 30 70 70 30 30<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Min.<br />

Column: Alltech ® Alltima C18, 5µm, 250 x 4.6mm (Part No. 88056)<br />

Mobile Phase: Water:Acetonitrile (5:95)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

Standards<br />

5<br />

7<br />

3<br />

6<br />

4<br />

1<br />

2<br />

Standards Mix<br />

10696<br />

1. Nicotine<br />

2. Quinine<br />

3. Diphenhydramine<br />

4. Nortriptyline<br />

5. 2,4, Dichlorophenoxy Acetic Acid<br />

6. 2,4, Dichlorophenoxy Propionic Acid<br />

7. 2,4, Dichlorophenoxy Butyric Acid<br />

1<br />

2<br />

3<br />

4<br />

Acids, Bases and Neutrals<br />

1. Uracil<br />

2. Amitriptyline<br />

3. Phenylvaleric Acid<br />

4. Toluene<br />

10695<br />

0 2 4 6 8 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 150 x 4.6mm (Part No. 5138812)<br />

Mobile Phase: 50mM Potassium Phosphate, pH3.0:Acetonitrile (50:50)<br />

Detector: UV at 254nm<br />

Dyes<br />

1 2 3<br />

4<br />

5<br />

Color Additives - Dyes<br />

6<br />

7<br />

8<br />

9 10 11<br />

0 10 20 30 40 50 Min.<br />

Column:<br />

1. Tartrazine<br />

2. Amaranth<br />

3. Indigo Carmine<br />

4. New Coccine<br />

5. Sunset Yellow<br />

6. Fast Green<br />

7. Brilliant Blue<br />

8. Erythosine<br />

9. Acid Red<br />

10. Phloxine<br />

11. Rosé Bengale<br />

Grom Sil 120 ODS-5 ST, 5μm, 150 x 4mm<br />

(Part No. 5113642)<br />

Mobile Phase: A: 10mM Ammonium Phosphate, pH6.0:Methanol (90:10)<br />

B: 10mM Ammonium Phosphate, pH6.0:Methanol (20:30)<br />

Gradient: Time: 0 40 60<br />

%B: 0 100 100<br />

Flow Rate:<br />

Detector:<br />

0.8mL/min<br />

UV at 254nm<br />

0 2 4 6 8 Min.<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 150 x 4.6mm (Part No. 5138812)<br />

Mobile Phase: 50mM Potassium Phosphate, pH3.0:Acetonitrile (50:50)<br />

Detector: UV at 254nm<br />

Solvents<br />

1<br />

2<br />

Caprolactams<br />

Caprolactams<br />

3<br />

1. N-Methylol Caprolactam<br />

2. Caprolactam<br />

3. N,N-Methylene-bis(Caprolactam)<br />

4. N,N-oxy-bis(Methylene)--Caprolactam<br />

0 2 4 6 8 10 12 Min.<br />

Column: GENESIS Jones FM15960E Genesis (C18, , 4μm, 4 µm, 150 4.6 x mm 4.6mm i.d. x (Part 150 mm) No. FM15960E)<br />

Flow: Mobile Phase: 1.0 mL/min Acetonitrile:20mM Phosphate, pH6.8 (22:78)<br />

Eluent: Flow Rate: Isocratic, 1.0mL/min 22% ACN in 20 mM phosphate, pH 6.8<br />

Detection: Detector: Absorbance, UV at 205nm<br />

Peaks: 1. N-methylol caprolactam, 2. Caprolactam,<br />

3. N,N-methylene-bis(caprolactam),<br />

4. N,N-oxy-bis(methylene)--caprolactam<br />

4<br />

452<br />

www.discoverysciences.com


hplc applications<br />

Fuels<br />

Petrochemicals<br />

Chelators<br />

Metal Chelators<br />

1<br />

8584<br />

1. Aliphatics<br />

2. Mono-aromatics<br />

3. Di-aromatics<br />

4. Polyaromatics<br />

2<br />

1. 2,2’-Dipyridyl<br />

2. 8-Hydroxyquinoline<br />

2 3<br />

1 4<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Jones Genesis ® Petro XL, 3µm, 250 x 4.6mm<br />

(Part No. FM25991E)<br />

Mobile Phase: Hexane<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 210nm<br />

0 2<br />

4 6 Min.<br />

Column: Alltech ® Alltima C18, 5µm, 150 x 4.6mm (Part No. 88052)<br />

Mobile Phase: 0.025M K2HPO4, pH7.0:Tetrahydrofuran:<br />

Methanol (50:25:25)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

1) ?-Cyclodextrin<br />

2) ?-Cyclodextrin<br />

3) ?-Cyclodextrin<br />

miscellaneous<br />

Paraffins<br />

Cyclodextrins<br />

Paraffin Analysis<br />

Paraffin C20-C30<br />

10429<br />

1<br />

2<br />

3<br />

Cyclodextrins<br />

Cyclodextrins<br />

1. γ-Cyclodextrin<br />

2. α-Cyclodextrin<br />

3. β-Cyclodextrin Column phase: GROM-SIL 120 O<br />

Column size: 150 x 4 mm<br />

Eluent:: water / methanol = 95 / 5<br />

Flow rate: 0.8 ml/min<br />

Pressure: 8.8 MPa<br />

Temperature: 30°C<br />

Detection: RI<br />

Injection: 5 µl (20 - 60 µg)<br />

0 2 4 6 8 10 12 14 16 18 20 22 Min.<br />

Column: Alltech ® Alltima HP C18 HiLoad, 3µm, 100 x 4.6mm<br />

(Part No. 87685)<br />

Mobile Phase: Acetonitrile:Dichloromethane (60:40)<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

0 5 10 15 20 25 Min.<br />

Column: Grom Sil 120 ODS-5 ST, 5μm, 150 x 4mm<br />

(Part No. 5113642)<br />

Mobile Phase: Water:Methanol (95:5)<br />

Flow Rate: 0.8mL/min<br />

Detector: RI<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

453


ic applications<br />

anions<br />

Anions<br />

1<br />

2<br />

3<br />

Anions in Reagent Grade Water<br />

by EPA Method 300.1<br />

4<br />

5<br />

6 7<br />

8<br />

0 4 8 12 16 20 24 Min.<br />

Column: Alltech ® Novosep A-2 Anion, 250 x 4mm (Part No. 51410)<br />

Mobile Phase: 3.6mM Sodium Carbonate<br />

Flow Rate: 0.8mL/min<br />

Column Temp: 43°C<br />

Detector: Suppressed Conductivity<br />

9<br />

10<br />

1. Fluoride<br />

2. Chlorite<br />

3. Bromate<br />

4. Chloride<br />

5. Nitrite<br />

6. Bromide<br />

7. Chlorate<br />

8. Nitrate<br />

9. Phosphate<br />

10. Sulfate<br />

10120<br />

1<br />

Anions in High Ionic Strength Water by<br />

EPA Method 300.1<br />

2<br />

3<br />

4 5<br />

6 7<br />

8<br />

9 10 11<br />

1. Fluoride<br />

2. Chlorite<br />

3. Bromate<br />

4. Chloride<br />

5. Nitrite-N<br />

6. Bromide<br />

7. Chlorate<br />

8. Dichloroacetate<br />

9. Nitrate-N<br />

10. Phosphate-P<br />

11. Sulfate<br />

10121<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 26 Min.<br />

Column: Alltech ® Novosep A-2 Anion, 250 x 4mm (Part No. 51410)<br />

Mobile Phase: 3.6mM Sodium Carbonate<br />

Flow Rate: 0.8mL/min<br />

Column Temp: 43°C<br />

Detector: Suppressed Conductivity<br />

Trace Bromate with Post Column Derivatization<br />

and UV Detection, EPA Method 317.0<br />

Arsenite and Arsenate<br />

10123<br />

9178<br />

2<br />

1. Chlorite<br />

2. Bromate<br />

3. Nitrite<br />

1<br />

2<br />

1. Arsenite<br />

2. Arsenate<br />

3<br />

1<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 Min.<br />

0 5 10 Min.<br />

Column: Alltech ® Novosep A-2 Anion, 250 x 4mm (Part No. 51410) Column: Alltech ® Allsep Anion, 100 x 4.6mm (Part No. 51207)<br />

Mobile Phase: 3.6mM Sodium Carbonate<br />

Mobile Phase: 4mM p-Hydroxybenzoic Acid, pH8.5<br />

Flow Rate: 0.8mL/min<br />

with Lithium Hydroxide<br />

Column Temp: 40°C<br />

Flow Rate: 1.0mL/min<br />

Reagent: o-Dianisidine<br />

Detector: Conductivity<br />

Detector: UV at 450nm<br />

Diet Cola<br />

1<br />

Toothpaste<br />

8458 8464<br />

1<br />

1. Aspartame<br />

2. Chloride<br />

3. Nitrate<br />

4. Sulfate<br />

4<br />

1. Fluoride<br />

2. Chloride<br />

3. Phosphate<br />

4. Monofluorophosphate<br />

2<br />

3<br />

4<br />

2 3<br />

0 2<br />

4<br />

6 8 10 Min. 0 4<br />

8 12 16 Min.<br />

Column: Alltech ® Allsep Anion, 100 x 4.6mm (Part No. 51207)<br />

Mobile Phase: 4mM Phthalic Acid, pH4.2 with Lithium Hydroxide<br />

Flow Rate: 1.2mL/min<br />

Detector: Conductivity<br />

Column: Alltech ® Allsep Anion, 100 x 4.6mm (Part No. 51207)<br />

Mobile Phase: 0.85mM Sodium Bicarbonate/0.9mM Sodium Carbonate<br />

Flow Rate: 1.2mL/min<br />

Detector: Suppressed Conductivity<br />

454 www.discoverysciences.com


ic applications<br />

2<br />

Anions<br />

13033<br />

2<br />

Bakery Additives<br />

13040<br />

1<br />

3<br />

4<br />

5<br />

7<br />

1. Fluoride<br />

2. Chloride<br />

3. Nitrite<br />

4. Bromide<br />

5. Nitrate<br />

6. Phosphate<br />

7. Sulfate<br />

1<br />

1. Iodate<br />

2. Bromate<br />

6<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 Min. 0 1 2 3 4 5 6 7 8 9 Min.<br />

Column: Alltech ® Allsep Anion, 100 x 4.6mm (Part No. 51207) Column: Alltech ® Allsep Anion, 100 x 4.6mm (Part No. 51207)<br />

Mobile Phase: 0.85mM Sodium Bicarbonate/0.9mM Sodium Carbonate Mobile Phase: 0.85mM NaHCO3/ 0.9mM NaHCO3<br />

Flow Rate: 1.2mL/min<br />

Flow Rate: 1.0mL/min<br />

Detector: Suppressed Conductivity<br />

Detector: Suppressed Conductivity<br />

anions<br />

Selenite, Selenate, Arsenate,<br />

Tungstate and Molybdate<br />

Selenite, Selenate, Tungstate, Molybdate and<br />

Seven Common Anions<br />

1<br />

2<br />

1. Fluoride<br />

2. Chloride<br />

3. Nitrite<br />

4. Bromide<br />

5. Nitrate<br />

6. Phosphate<br />

7. Selenite<br />

8. Sulfate<br />

9. Arsenate<br />

10. Selenate<br />

11. Tungstate<br />

12. Molybdate<br />

8610<br />

1<br />

2 3<br />

4 5<br />

1. Fluoride<br />

2. Chloride<br />

3. Nitrite<br />

4. Bromide<br />

5. Nitrate<br />

6. Phosphate<br />

7. Selenite<br />

8. Sulfate<br />

9. Selenate<br />

10. Tungstate<br />

11. Molybdate<br />

9176<br />

3<br />

6 7<br />

8 9<br />

10 11<br />

4 5<br />

6<br />

7 8 9 10 11 12<br />

0 10 20 30 40 Min. 0 5 10 15 20 25 Min.<br />

Column: Alltech ® Allsep Anion, 150 x 4.6mm (Part No. 51209) Column: Alltech ® Allsep A-2, 50 x 4.6mm (Part No. 51221)<br />

Mobile Phase: 0.85mM Sodium Bicarbonate/0.9mM Sodium Carbonate Mobile Phase: 2.1mM Sodium Bicarbonate/1.6mM Sodium Carbonate<br />

Flow Rate: 1.2mL/min<br />

Flow Rate: 2.0mL/min<br />

Detector: Suppressed Conductivity<br />

Detector: Suppressed Conductivity<br />

Anions with Phthalic Acid Mobile Phase<br />

2<br />

8432<br />

1<br />

4<br />

Oxalate in Urine<br />

8451<br />

1<br />

3<br />

4 5<br />

6<br />

1. Fluoride<br />

2. Chloride<br />

3. Nitrite<br />

4. Bromide<br />

5. Nitrate<br />

6. Sulfate<br />

3<br />

1. Chloride<br />

2. Nitrate<br />

3. Phosphate<br />

4. Sulfate<br />

5. Oxalate<br />

2<br />

5<br />

0 2<br />

4 6 8 10 Min. 0 4<br />

Column: Alltech ® Allsep Anion, 100 x 4.6mm (Part No. 51207)<br />

Mobile Phase: 4mM Phthalic Acid, pH4.2 with Lithium Hydroxide<br />

Flow Rate: 1.0mL/min<br />

Column Temp: 35°C<br />

Detector: Conductivity<br />

8 12 16 20 Min.<br />

Column: Alltech ® Allsep Anion, 100 x 4.6mm (Part No. 51207)<br />

Mobile Phase: 0.85mM Sodium Bicarbonate/0.9mM Sodium Carbonate<br />

Flow Rate: 1.2mL/min<br />

Detector: Suppressed Conductivity<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

455


ic applications<br />

Anions<br />

1 2<br />

Common Anions Rapid Analysis<br />

1. Fluoride<br />

2. Chloride<br />

3. Nitrite<br />

4. Bromide<br />

5. Nitrate<br />

6. Phosphate<br />

7. Sulfate<br />

9174<br />

1<br />

2 3 4<br />

5<br />

6<br />

Weak Acid Anions<br />

1. Borate<br />

2. Silicate<br />

3. Formate<br />

4. Sulfide<br />

5. Chloride<br />

6. Cyanide<br />

5697<br />

3<br />

4<br />

5<br />

6<br />

7<br />

anions<br />

0 2 4 6 8 10 Min.<br />

Column: Alltech ® Allsep A-2, 50 x 4.6mm (Part No. 51221)<br />

Mobile Phase: 2.8mM Sodium Bicarbonate/2.2mM Sodium Carbonate<br />

Flow Rate: 2.0mL/min<br />

Detector: Suppressed Conductivity<br />

0 9 18 Min.<br />

Column: Alltech ® Anion/R, 10µm, 250 x 4.1mm (Part No. 269029)<br />

Mobile Phase: 4mM Sodium Hydroxide/0.1mM Sodium Benzoate<br />

Flow Rate: 1.5mL/min<br />

Detector: Conductivity<br />

1<br />

Organic and Inorganic Anions<br />

Weak Acid Anions<br />

5<br />

3<br />

4<br />

2<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

1. Fluoride<br />

2. Acetate<br />

3. Formate<br />

4. Chlorite<br />

5. Chloride<br />

6. Nitrite<br />

7. Bromide<br />

8. Chlorate<br />

9. Nitrate<br />

10. Phosphate<br />

11. Sulfate<br />

8747<br />

1<br />

2 3 4<br />

5<br />

1. Fluoride<br />

2. Acetate<br />

3. Formate<br />

4. Chlorite<br />

5. Chloride<br />

13041<br />

0 6 12 18 24 Min. 0 1 2 3 4 5 6 7 8 9 Min.<br />

Column: Alltech ® Allsep A-2 Anion, 100 x 4.6mm (Part No. 51219) Column: Alltech ® Allsep A-2 Anion, 100 x 4.6mm (Part No. 51219)<br />

Mobile Phase: 2.1mM Sodium Bicarbonate/1.6mM Sodium Carbonate Mobile Phase: 2.1mM Sodium Bicarbonate/1.6mM Sodium Carbonate<br />

Flow Rate: 2.0mL/min<br />

Flow Rate: 1.0mL/min<br />

Detector: Suppressed Conductivity<br />

Detector: Suppressed Conductivity<br />

Selenite, Selenate, and Other Anions<br />

Separation of Sulfite and Sulfate<br />

8611 6316<br />

1<br />

2 3 4 5 6<br />

7<br />

8<br />

9<br />

1. Fluoride<br />

2. Chloride<br />

3. Nitrite<br />

4. Bromide<br />

5. Nitrate<br />

6. Selenite<br />

7. Phosphate<br />

8. Sulfate<br />

9. Selenate<br />

1<br />

2<br />

3 4 5 6<br />

7<br />

8<br />

9<br />

1. Water<br />

2. Fluoride<br />

3. Chloride<br />

4. Nitrite<br />

5. Bromide<br />

6. Nitrate<br />

7. Phosphate<br />

8. Sulfite<br />

9. Sulfate<br />

0 4<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

8 12 16 Min.<br />

Alltech ® Sarasep AN1, 9µm, 250 x 4.6mm<br />

(Part No. 38140)<br />

0.75mM Sodium Bicarbonate, 2.2mM Sodium Carbonate<br />

1.0mL/min<br />

Suppressed Conductivity<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column: Alltech ® ICSep AN1, 9µm, 250 x 4.6mm<br />

(Part No. 38140)<br />

Mobile Phase: 1.8mM Sodium Bicarbonate, 1.8mM Sodium Carbonate<br />

Flow Rate: 1.0mL/min<br />

Detector: Suppressed Conductivity<br />

456 www.discoverysciences.com


ic applications<br />

3<br />

Anions with pHBA Mobile Phase<br />

8750<br />

2<br />

7<br />

Drinking Water<br />

8954<br />

1<br />

2<br />

4<br />

5 6<br />

7 8<br />

1. Fluoride<br />

2. Carbonate<br />

3. Chloride<br />

4. Nitrite<br />

5. Bromide<br />

6. Nitrate<br />

7. Phosphate<br />

8. Sulfate<br />

9. System Peak<br />

1<br />

1. Fluoride<br />

2. Chloride<br />

3. Bicarbonate<br />

4. Nitrite<br />

5. Nitrate<br />

6. Phosphate<br />

7. Sulfate<br />

9<br />

0 5 10 15 20 25 30 Min.<br />

Column: Alltech ® Allsep A-2 Anion, 100 x 4.6mm (Part No. 51219)<br />

Mobile Phase: 5mM p-Hydroxybenzoic Acid, pH8.2<br />

with Lithium Hydroxide<br />

Flow Rate: 2.0mL/min<br />

Detector: Conductivity<br />

4 6 3<br />

5<br />

0 6 12 18 24 Min.<br />

Column: Alltech ® Allsep A-2 Anion, 100 x 4.6mm (Part No. 51219)<br />

Mobile Phase: 2.8mM Sodium Bicarbonate/2.2mM Sodium Carbonate<br />

Flow Rate: 1.5mL/min<br />

Detector: Suppressed Conductivity<br />

anions<br />

1<br />

Chloride and Bromide (3500:1)<br />

Nickel Plating Bath Solution<br />

9172 9173<br />

2<br />

1. Chloride (3500ppm)<br />

2. Bromide (1ppm)<br />

1. Fluoride<br />

2. Unknown<br />

3. Chloride<br />

4. System<br />

5. Sulfate<br />

2<br />

3<br />

5<br />

1<br />

4<br />

0 2 4 6 8 10 12 Min.<br />

Column: Alltech ® Allsep A-2 Anion, 100 x 4.6mm (Part No. 51219)<br />

Mobile Phase: 2.8mM Sodium Bicarbonate/2.2mM Sodium Carbonate<br />

Flow Rate: 1.5mL/min<br />

Detector: Suppressed Conductivity<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column: Alltech ® Allsep A-2 Anion, 50 x 4.6mm (Part No. 51221)<br />

Mobile Phase: 2.8mM Sodium Bicarbonate/2.2mM Sodium Carbonate<br />

Flow Rate: 2.0mL/min<br />

Detector: Suppressed Conductivity<br />

Formate, Oxalate, Iodide, and Seven Common Anions<br />

3 4<br />

EDTA<br />

1<br />

9175 8284<br />

1 3<br />

1. Fluoride<br />

6. Nitrate<br />

1. Nitrite<br />

2. Formate<br />

7. Phosphate<br />

2<br />

2. EDTA<br />

3. Chloride<br />

8. Sulfate<br />

3. Nitrate<br />

4. Nitrite<br />

9. Oxalate<br />

4. Bromide<br />

4<br />

5. Bromide<br />

10. Iodide<br />

2<br />

5 6 8<br />

9<br />

7<br />

10<br />

0 2 4 6 8 10 12 14 16 Min.<br />

Column: Alltech ® Allsep A-2, 50 x 4.6mm (Part No. 51221)<br />

Mobile Phase: 2.8mM Sodium Bicarbonate:2.2mM Sodium Carbonate:<br />

2% Acetonitrile<br />

Flow Rate: 2.0mL/min<br />

Detector: Suppressed Conductivity<br />

0 4 8 12 16 20 24 Min.<br />

Column: Alltech ® Anion/S, 100 x 4.6mm (Part No. 269012)<br />

Mobile Phase: 1.5mM Sulfuric Acid<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 210nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

457


ic applications<br />

Anions<br />

3<br />

Anion Standards<br />

6159<br />

Haloacetic Acids<br />

13038<br />

2<br />

4<br />

1<br />

5<br />

7<br />

6<br />

8<br />

1. Fluoride<br />

2. Bicarbonate<br />

3. Chloride<br />

4. Nitrite<br />

5. Bromide<br />

6. Nitrate<br />

7. Phosphate<br />

8. Sulfate<br />

1<br />

2<br />

1. Chloro-difluoro Acetic Acid<br />

2. Difluoro Acetic Acid<br />

anions<br />

0 9 18 Min. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Min.<br />

Column: Alltech ® Anion/R, 10µm, 250 x 4.1mm (Part No. 269029)<br />

Mobile Phase: 5mM p-Hydroxybenzoic Acid, pH8.5<br />

with Lithium Hydroixde<br />

Flow Rate: 1.5mL/min<br />

Detector: Conductivity<br />

Column: Alltech ® OA-1000, 9µm, 300 x 6.5mm (Part No. 9046)<br />

Mobile Phase: 1.0% Phosphoric Acid<br />

Flow Rate: 0.8mL/min<br />

Column Temp: 35°C<br />

Detector: Conductivity (Non-Suppressed)<br />

1<br />

Organic Acid Standards<br />

13037<br />

2<br />

3<br />

1. Oxalic Acid<br />

2. Maleic Acid<br />

3. Malic Acid<br />

4. Succinic Acid<br />

5. Formic Acid<br />

6. Acetic Acid<br />

4 5<br />

6<br />

6 8 10 12 14 16 18 20 22 24 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Alltech ® Anion Exclusion, 10µm, 300 x 7.5mm<br />

(Part No. 269062)<br />

1.5mM Sulfuric Acid<br />

0.6mL/min<br />

Conductivity<br />

458 www.discoverysciences.com


ic applications<br />

Cations<br />

Rapid Analysis of Monovalent<br />

and Divalent Cations<br />

13013<br />

Morpholine and Group I & II Cations<br />

8632<br />

2<br />

3<br />

4<br />

1<br />

5<br />

6<br />

1. Lithium<br />

2. Sodium<br />

3. Ammonium<br />

4. Potassium<br />

5. Magnesium<br />

6. Calcium<br />

2 3 4 5 6<br />

1<br />

7<br />

1. Lithium<br />

2. Sodium<br />

3. Ammonium<br />

4. Potassium<br />

5. Morpholine<br />

6. Magnesium<br />

7. Calcium<br />

0 1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7 8 9 Min.<br />

0 4<br />

8 12 16 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Alltech ® Universal Cation HR, 3µm, 53 x 7.0mm<br />

(Part No. 23109)<br />

3mM Methanesulfonic Acid<br />

2.5mL/min<br />

Conductivity<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Alltech ® Universal Cation, 7µm, 100 x 4.6mm<br />

(Part No. 27106)<br />

3mM Methanesulfonic Acid<br />

1.0mL/min<br />

Conductivity<br />

cations<br />

3<br />

2<br />

1<br />

5<br />

4<br />

6<br />

Rubidium and Barium<br />

7<br />

8<br />

1. Lithium<br />

2. Sodium<br />

3. Ammonium<br />

4. Potassium<br />

5. Rubidium<br />

6. Magnesium<br />

7. Calcium<br />

8. Barium<br />

6292<br />

1<br />

4<br />

2<br />

3<br />

5<br />

Ethanolamines<br />

1. Monoethanolamine<br />

2. Diethanolamine<br />

3. Triethanolamine<br />

4. Magnesium<br />

5. Calcium<br />

6315<br />

0 10 20 30 40 Min.<br />

0 10 20 30 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

1<br />

Alltech ® Universal Cation, 7µm, 100 x 4.6mm<br />

(Part No. 27106)<br />

5mM Hydrochloric Acid<br />

1.0mL/min<br />

Conductivity<br />

Trace Level Ammonium in Brine<br />

4<br />

8462<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Alltech ® Universal Cation, 7µm, 100 x 4.6mm<br />

(Part No. 27106)<br />

5mM Hydrochloric Acid<br />

1.0mL/min<br />

Conductivity<br />

Metal-Cyano Complexes<br />

5358<br />

3<br />

5<br />

1. Sodium<br />

2. Ammonium<br />

3. Potassium<br />

4. Magnesium<br />

5. Calcium<br />

1<br />

1. Fe(CN)6 4-<br />

2. Ag(CN)2 -<br />

3. Fe(CN)6 3-<br />

4. Ni(CN)4 2-<br />

5. Au(CN)2 -<br />

2 3 4<br />

5<br />

2<br />

0 5<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

10 15 20 Min.<br />

Alltech ® Universal Cation, 7µm, 100 x 4.6mm<br />

(Part No. 27106)<br />

2.5mM Oxalic Acid<br />

1.0mL/min<br />

Conductivity<br />

0 10 20 30 40 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Alltech ® Transition Metal C18, 7µm, 250 x 4.6mm<br />

(Part No. 269067)<br />

5mM Tetrabutylammonium Sulfate<br />

(Preformulated Alltech ® Low UV IPC A, Part No. 185149)<br />

in 30% Acetonitrile<br />

0.7mL/min<br />

UV at 214nm<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

459


ic applications<br />

Cations<br />

1<br />

Cations in Coffee Extract<br />

Alkali Metals<br />

1<br />

6303 5204<br />

1. Potassium<br />

2. Magnesium<br />

3. Calcium<br />

2<br />

3<br />

1. Lithium<br />

2. Sodium<br />

3. Ammonium<br />

4. Potassium<br />

5. Cesium<br />

2<br />

4 5<br />

3<br />

cations<br />

0 13 26 Min.<br />

Column: Alltech ® Universal Cation, 7µm, 100 x 4.6mm<br />

(Part No. 27106)<br />

Mobile Phase: 5mM Hydrochloric Acid<br />

Flow Rate: 1.0mL/min<br />

Detector: Conductivity<br />

0 1 2 3 4 5 Min.<br />

Column: Hamilton ® PRP-X200, 10µm, 150 x 4.1mm<br />

(Part No. 79441)<br />

Mobile Phase: 4mM Nitric Acid in 30% Methanol<br />

Flow Rate: 2.0mL/min<br />

Detector: Conductivity<br />

12<br />

3<br />

4<br />

5 6 7<br />

8<br />

Metal Ions<br />

9<br />

1. Lithium<br />

2. Sodium<br />

3. Ammonium<br />

4. Potassium<br />

5. Nickel<br />

6. Zinc<br />

7. Cobalt<br />

8. Magnesium<br />

9. Calcium<br />

1<br />

2 34<br />

5<br />

6<br />

Transition Metals<br />

10318 13042<br />

7<br />

8<br />

1. Copper<br />

2. Sodium<br />

3. Ammonium<br />

4. Potassium<br />

5. Zinc<br />

6. Lead<br />

7. Magnesium<br />

8. Calcium<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Min.<br />

Column: Alltech ® Universal Cation, 7µm, 100 x 4.6mm<br />

(Part No. 27106)<br />

Mobile Phase: 2mM Tartaric Acid/1mM Oxalic Acid<br />

Flow Rate: 1.0mL/min<br />

Detector: Conductivity<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

Column: Alltech ® Universal Cation, 7µm, 100 x 4.6mm<br />

(Part No. 27106)<br />

Mobile Phase: 3mM Tartaric Acid/2mM Oxalic Acid<br />

Flow Rate: 1.0mL/min<br />

Detector: Conductivity<br />

Cesium and Strontium<br />

13035<br />

12 3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

1. Lithium<br />

2. Sodium<br />

3. Ammonium<br />

4. Potassium<br />

5. Cesium<br />

6. Magnesium<br />

7. Calcium<br />

8. Strontium<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Min.<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Alltech ® Universal Cation, 7µm, 100 x 4.6mm<br />

(Part No. 27106)<br />

3mM Methanesulfonic Acid<br />

1.0mL/min<br />

Conductivity<br />

460 www.discoverysciences.com


ic applications<br />

Surfactants<br />

1<br />

2<br />

Short and Long Chain Cationic Surfactants<br />

3<br />

4 5<br />

6<br />

7<br />

2<br />

Toothpaste<br />

10317 8425<br />

1. Tetramethyl Ammonium<br />

1<br />

1. Unidentified<br />

2. Tetraethyl Ammonium<br />

2. Dodecyl Sulfate (C12)<br />

3. Tetrapropyl Ammonium<br />

4. Tetrabutyl Ammonium<br />

5. Dodecyltrimethyl Ammonium<br />

6. Cetyltrimethyl Ammonium<br />

7. Myristyltrimethyl Ammonium<br />

0 2 4 6 8 10 12 14 16 18 20 22 Min.<br />

0 2<br />

4 6 8 10 12 14 16 18 20 Min.<br />

Column: Alltech ® Surfactant/R Column, 7µm, 150 x 4.6mm<br />

(Part No. 25101)<br />

Mobile Phase: A: 2mM Nonafluoropentanoic Acid<br />

B: Acetonitrile<br />

Gradient: Time: 0 5 8 20<br />

%B: 30 30 35 80<br />

Flow Rate: 1.0mL/min<br />

Detector: Suppressed Conductivity<br />

Column: Alltech ® Surfactant/R, 7µm,150 x 4.6mm<br />

(Part No. 25101)<br />

Mobile Phase: A: 10mM Lithium Hydroxide<br />

B: Water:Acetonitrile:Methanol (20:60:20)<br />

Gradient: Time: 0 3 10 20<br />

%B: 3 3 20 50<br />

Flow Rate: 1.0mL/min<br />

Detector: Suppressed Conductivity<br />

surfactants<br />

Alkyl Sulfates and Alkanesulfonates<br />

Alkyl Sulfates<br />

8428<br />

1<br />

5998<br />

1 2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

1. C6 Sulfate<br />

2. C6 Sulfonate<br />

3. C7 Sulfonate<br />

4. C8 Sulfonate<br />

5. C8 Sulfate<br />

6. C10 Sulfonate<br />

7. C10 Sulfate<br />

8. C12 Sulfonate<br />

9. C12 Sulfate<br />

2<br />

3<br />

1. Octyl Sulfate<br />

2. Decyl Sulfate<br />

3. Dodecyl Sulfate<br />

0 4<br />

8 12 16 20 Min.<br />

Column: Alltech ® Surfactant/R, 150 x 4.6mm (Part No. 25101)<br />

Mobile Phase: A: 10mM Lithium Hydroxide<br />

B: Water:Acetonitrile:Methanol (20:60:20)<br />

Gradient: Time: 0 3 10 20<br />

%B: 3 3 20 50<br />

Flow Rate: 1.0mL/min<br />

Detector: Suppressed Conductivity<br />

0 6 12 18 24 30 Min.<br />

Column: Alltech ® Surfactant C8, 5µm, 250 x 4.6mm<br />

(Part No. 269072)<br />

Mobile Phase: 0.02g/L Ammonium Acetate in 40% Methanol<br />

Flow Rate: 1.2mL/min<br />

Detector: Conductivity<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

461


gc applications<br />

Abused Drugs<br />

2<br />

1<br />

3<br />

4<br />

Amphetamines<br />

1. Amphetamine<br />

2. Methamphetamine<br />

3. Propylamphetamine<br />

4. Ephedrine<br />

Club Drugs<br />

1013 1. Methamphetamine<br />

5. 2,3-MDMA<br />

2. 4-Methoxyamphetamine<br />

6. 3,4-MDMA<br />

2637<br />

3. 2,3-MDA<br />

7. 4-Bromo-2,5-dimethoxy-<br />

4. 3,4-MDA<br />

phenethylamine<br />

<br />

<br />

8. Ketamine<br />

9. Phencyclidine<br />

10. Cocaine<br />

11. Flunitazepam<br />

<br />

<br />

<br />

<br />

<br />

drugs<br />

0 1 2 3 4 Min.<br />

Column: Econo-Cap EC-1, 15m x 0.53mm x 1.20µm<br />

(Part No. 19650)<br />

Temp: 130°C<br />

Carrier Gas: Helium at 8.7mL/min<br />

Detector: FID<br />

1<br />

4<br />

Drug Mixture<br />

8<br />

0042<br />

1. Methylenedioxymethamphetamine<br />

(MDMA)<br />

2. Benzocaine<br />

3. Meperidine<br />

3<br />

2<br />

4. Phencyclidine (PCP)<br />

10<br />

5. Caffeine<br />

6. Procaine<br />

7<br />

13<br />

7. Mepivacaine<br />

5<br />

8. Methadone<br />

6<br />

9. Atropine<br />

10. Cocaine<br />

9<br />

11 12 11. Oxazepam<br />

12. Codeine<br />

13. Diazepam<br />

<br />

<br />

Column: Heliflex ® AT-5ms, 15m x 0.25mm x 0.25μm<br />

(Part No. 15801)<br />

Temp:<br />

140°C (1 min hold) to 300°C at 10°C/min<br />

Carrier Gas: Helium at 0.8mL/min (28cm/sec)<br />

Detector: FID at 340°C<br />

Drug Mixture<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

2483<br />

1. Caffeine<br />

2. Glutethimide<br />

3. Lidocaine<br />

4. Primary Methadone Metabolite<br />

5. Methadone<br />

6. Cocaine<br />

7. Desipramine<br />

0 4 8 12 16 Min.<br />

Column: Heliflex ® Drug Two, 30m x 0.25mm x 0.25µm<br />

(Part No. 13746)<br />

Temp:<br />

230°C to 250°C at 5°C/min<br />

Carrier Gas: Helium at 0.64mL/min<br />

Detector: FID<br />

Horse Racing Drug Mixture<br />

0<br />

4 8 12 16 20 24 Min.<br />

Column: Econo-Cap EC-5, 30m x 0.25mm x 0.25µm<br />

(Part No. 19647)<br />

Temp: 210°C<br />

Carrier Gas: Helium at 22cm/sec<br />

Detector: FID<br />

<br />

2597<br />

<br />

<br />

<br />

<br />

<br />

<br />

1. Amobarbital<br />

2. Pentobarbital<br />

3. Caffeine<br />

4. Diphenhydramine<br />

5. Trimipramine<br />

6. Pentazocine<br />

7. Phenytoin<br />

8. Diazepam<br />

9. Nordiazepam<br />

10. Boldenone<br />

<br />

<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-1ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15897)<br />

100°C (2 min hold) to 300°C at 15°C/min, then to<br />

320°C at 20°C/min<br />

Helium at 1.23mL/min<br />

FID<br />

462<br />

www.discoverysciences.com


gc applications<br />

Ephedra Standards via MSTFA<br />

<br />

<br />

<br />

<br />

<br />

1. Methylephedrine<br />

2. Norpseudoephedrine<br />

3. Norephedrine<br />

4. Ephedrine<br />

5. Pseudoephedrine<br />

6. Synephrine<br />

MDMA & MDA Analogs<br />

2663 2562<br />

1<br />

2 3 4<br />

1. 2,3-MDA<br />

2. 3,4-MDA<br />

3. 2,3-MDMA<br />

4. 3,4-MDMA<br />

<br />

<br />

0<br />

1 2 3 4 5 6 Min.<br />

Column: Heliflex ® AT-5ms, 30m x 0.25mm x 0.25μm<br />

(Part No. 15807)<br />

Temp:<br />

150°C (2 min hold) to 230°C at 10°C/min<br />

Carrier Gas: Helium at 0.8mL/min (26cm/sec)<br />

Detector: FID at 310°C<br />

Column: Heliflex ® AT-5ms, 15m x 0.25mm x 0.25µm<br />

(Part No. 15801)<br />

Temp: 160°C<br />

Carrier Gas: Helium at 0.7mL/min (25cm/sec)<br />

Detector: FID<br />

Meperidine and Metabolite<br />

Nicotine and Metabolite<br />

2<br />

1027<br />

1<br />

1030<br />

1<br />

1. Meperidine<br />

2. Normeperidine<br />

2<br />

1. Nicotine<br />

2. Cotinine<br />

drugs<br />

0 1234 567 Min.<br />

Column: Econo-Cap EC-5, 30m x 0.25mm x 0.25µm<br />

(Part No. 19647)<br />

Temp: 240°C<br />

Carrier Gas: Helium at 0.65mL/min<br />

Detector: FID<br />

0 2 4 6 8 10 Min.<br />

Column: Econo-Cap EC-1, 30m x 0.25mm x 0.25µm<br />

(Part No. 19652)<br />

Temp: 180°C<br />

Carrier Gas: Helium at 0.65mL/min<br />

Detector: FID<br />

Drug Screening<br />

<br />

1. Methoxyflurane<br />

2. Trimethadione<br />

3. Amphetamine<br />

4. Methamphetamine<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

5. α,α-Dimethyl-β-methylsuccinimide<br />

6. Ethosuximide<br />

7. Propylamphetamine<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

8. 1,3-Dimethylbarbituric Acid<br />

9. Nicotine<br />

10. Ethinamate<br />

11. Metharbital<br />

12. Phendimetrazine<br />

13. Barbital<br />

14. Methyprylon<br />

15. Aprobarbital<br />

16. Methsuximide<br />

17. Butabarbital<br />

18. Phenacetin<br />

19. Amobarbital<br />

20. Pentobarbital<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

21. Meperidine<br />

22. Secobarbital<br />

23. Ethotoin<br />

24. Benzphetamine<br />

25. Hexobarbital<br />

26. Lidocaine<br />

27. Mephobarbital<br />

28. Doxylamine<br />

29. Tripelennamine<br />

30. Chlorpheniramine<br />

31. Brompheniramine<br />

32. Cocaine<br />

33. Imipramine<br />

Econo-Cap EC-5, 30m x 0.25mm x 0.25µm<br />

(Part No. 19647)<br />

100°C to 300°C at 10°C/min<br />

Helium at 0.65mL/min<br />

FID<br />

1841<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

463


gc applications<br />

Abused Drugs<br />

2<br />

1<br />

3<br />

Opiates<br />

1. 6-Acetylcodeine<br />

2. 6-Monoacetylmorphine<br />

3. Diacetylmorphine (Heroin)<br />

Stimulant Drug Mixture<br />

1026<br />

<br />

<br />

2581<br />

1. Amphetamine<br />

<br />

2. Methamphetamine<br />

3. Methylphenidate<br />

4. Caffeine<br />

5. Cocaine<br />

<br />

0<br />

4 8 12 16 Min.<br />

Column: Econo-Cap EC-5, 30m x 0.25mm x 0.25µm<br />

(Part No. 19647)<br />

Temp: 260°C<br />

Carrier Gas: Helium at 0.65mL/min<br />

Detector: FID<br />

<br />

Column: Heliflex ® AT-1ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15897)<br />

Temp:<br />

150°C (4 min hold) to 250°C at 10°C/min<br />

Carrier Gas: Helium at 0.68mL/min (23cm/sec)<br />

Detector: FID<br />

Stimulants<br />

Underivatized Basic Drugs<br />

drugs<br />

1<br />

2<br />

3<br />

4<br />

5<br />

1. Amphetamine<br />

2. Methamphetamine<br />

3. Methylphenidate<br />

4. Caffeine<br />

5. Cocaine<br />

1031<br />

1. Amphetamine<br />

2. Methamphetamine<br />

3. Nicotine<br />

2 3<br />

1<br />

4<br />

5<br />

6<br />

7<br />

8<br />

4. Ephedrine<br />

5. Benzocaine<br />

6. Benzphetamine<br />

1011<br />

12<br />

9<br />

13<br />

1415<br />

18<br />

16<br />

17<br />

7. Phencyclidine<br />

8. Doxylamine<br />

9. Procaine<br />

10. Methadone<br />

11. Imipramine<br />

12. Cocaine<br />

13. Desipramine<br />

14. Scopolamine<br />

15. Codeine<br />

16. Norcodeine<br />

17. Morphine<br />

18. Heroin<br />

1870<br />

0<br />

4 8 12 16 20 Min.<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Econo-Cap EC-1, 30m x 0.25mm x 0.25µm<br />

(Part No. 19652)<br />

150°C (4 min hold) to 250°C at 10°C/min<br />

Helium at 0.65mL/min<br />

FID<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-20, 30m x 0.25mm x 0.25µm<br />

(Part No. 13857)<br />

150°C (2 min hold) to 290°C at 10°C/min<br />

Helium at 0.65mL/min<br />

FID<br />

Nutraceuticals<br />

Sterols in Saw Palmetto<br />

1. Campesterol<br />

2. Stigmasterol<br />

3. Sitosterol<br />

1 2<br />

3<br />

2580<br />

1<br />

2<br />

3<br />

Kava-Kava Lactones<br />

4<br />

5<br />

6<br />

1. Dihydrokavain<br />

2. Kavain<br />

3. Desmethoxyyangonin<br />

4. Dihydromethysticin<br />

5. Yangonin<br />

6. Methysticin<br />

2559<br />

0 3 6 9 12 15 18 21 24 27 Min. 0 2 4 6 8 10 12 Min.<br />

Column: Heliflex ® AT-5ms, 60m x 0.25mm x 0.25µm<br />

Column: Heliflex ® AT-5ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15891)<br />

(Part No. 15807)<br />

Temp:<br />

275°C (1 min hold) to 300°C at 20°C/min<br />

Temp:<br />

250°C to 280°C at 5°C/min<br />

Carrier Gas: Helium at 0.9mL/min (25cm/sec)<br />

Carrier Gas: Helium at 0.72mL/min (23cm/sec)<br />

Detector: FID at 325°C<br />

Detector: FID<br />

464<br />

www.discoverysciences.com


gc applications<br />

Organic Volatile Impurities<br />

12<br />

3<br />

4<br />

5<br />

6<br />

7<br />

USP 467 — Trace Volatiles<br />

8<br />

1. Ethylene Oxide<br />

2. Impurity<br />

3. Methylene Chloride<br />

4. Chloroform<br />

5. Benzene<br />

6. Trichloroethylene<br />

7. 1,4-Dioxane<br />

8. Dimethyl Sulfoxide<br />

1797<br />

1<br />

2<br />

3<br />

4<br />

5 6<br />

USP 467 — Method V<br />

1. Ethylene Oxide<br />

2. Methylene Chloride<br />

3. Chloroform<br />

4. Benzene<br />

5. Trichloroethylene<br />

6. 1,4-Dioxane<br />

1866<br />

0 3 6 9 12 15 18 Min.<br />

Column: Heliflex ® AT-5, 30m x 0.53mm x 5.00µm<br />

(Part No. 16859)<br />

Temp:<br />

35°C (5 min hold) to 175°C at 8°C/min<br />

Carrier Gas: Helium at 35cm/sec<br />

Detector: FID at 260°C<br />

0 4 8 12 16 20 Min.<br />

Column: Heliflex ® AT-624, 30m x 0.53mm x 3.00µm<br />

(Part No. 16889)<br />

Temp: 40°C<br />

Carrier Gas: Helium at 35cm/sec<br />

Detector: FID<br />

Pharmaceutical Solvents (Class 2) Composite Mix<br />

0<br />

1 2<br />

Column:<br />

Temp:<br />

Carrier:<br />

Detector:<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

13<br />

12<br />

17<br />

18<br />

14<br />

15<br />

16<br />

19<br />

20<br />

21<br />

22<br />

24 23<br />

25,26<br />

5 10 15 20 25 30 Min.<br />

Heliflex ® AT-5ms, 30m x 0.25mm x 1.00µm<br />

(Part No. 15809)<br />

40°C (8 min hold) to 105°C at 5°C/min, then to 225°C at 20°C/min<br />

Helium at 1.05mL/min (27cm/sec)<br />

FID<br />

27<br />

28<br />

29<br />

30<br />

1. Methanol<br />

2. Acetonitrile<br />

3. Dichloromethane<br />

4. Nitromethane<br />

5. trans-1,2-Dichoroethene<br />

6. Hexane<br />

7. cis-1,2-Dichloroethene<br />

8. Chloroform<br />

9. 2-Methoxyethanol<br />

10. 1,2-Dimethoxyethane<br />

11. Cyclohexane<br />

12. Formamide<br />

13. Ethylene Glycol<br />

14. 1,1,2-Trichloroethene<br />

15. 1,4-Dioxane<br />

16. 2-Ethoxyethanol<br />

17. Methylcyclohexane<br />

18. Pyridine<br />

19. Toluene<br />

20. N,N-Dimethylformamide<br />

21. Methylbutyl Ketone<br />

22. Chlorobenzene<br />

23. N,N-Dimethylacetamide<br />

24. Ethylbenzene<br />

25. m-Xylene<br />

26. p-Xylene<br />

27. o-Xylene<br />

28. N-Methylpyrrolidone<br />

29. Tetralin<br />

30. Sulfolane<br />

2566<br />

drugs<br />

Blood Alcohols<br />

Blood Alcohol Test Mix<br />

1<br />

3<br />

1016<br />

Pharmaceuticals<br />

Sedatives<br />

1033<br />

2<br />

4<br />

5<br />

1. Acetaldehyde<br />

2. Acetone<br />

3. Methanol<br />

4. 2-Propanol<br />

5. Ethanol<br />

<br />

<br />

1. Alprazolam<br />

2. Triazolam<br />

0 1 2 3 4 5 Min.<br />

Column: Econo-Cap EC-Wax , 30m x 0.32mm x 0.25µm<br />

(Part No. 19654)<br />

Temp: 50°C<br />

Carrier Gas: Helium at 1.08mL/min<br />

Detector: FID<br />

<br />

Column: Econo-Cap EC-5, 30m x 0.25mm x 0.25µm<br />

(Part No. 19647)<br />

Temp: 280°C<br />

Carrier Gas: Helium at 0.65mL/min<br />

Detector: FID<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

465


gc applications<br />

Pharmaceuticals<br />

1 2<br />

Depressants<br />

3<br />

4<br />

5<br />

1. Glutethimide<br />

2. Methaqualone<br />

3. Diazepam<br />

4. Chlorpromazine<br />

5. Flurazepam<br />

2560<br />

1<br />

2<br />

3<br />

4<br />

Anticonvulsants<br />

5 6<br />

1. Ethosuximide<br />

2. Methsuximide<br />

3. Normethsuximide<br />

4. Mephenytoin<br />

5. PEMA<br />

6. MPEMA<br />

2568<br />

0<br />

2 4 6 8 10 12 14 Min.<br />

Column: Heliflex ® AT-5ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15807)<br />

Temp: 270°C<br />

Carrier Gas: Helium at 0.65mL/min (24cm/sec)<br />

Detector: FID<br />

0 1 2 3 4 5 6 Min.<br />

Column: Heliflex ® AT-5ms, 15m x 0.25mm x 0.25µm<br />

(Part No. 15801)<br />

Temp:<br />

190°C (1 min hold) to 235°C at 10°C/min<br />

Carrier Gas: Helium at 0.7mL/min (26cm/sec)<br />

Detector: FID<br />

Antidepressants<br />

Antihistamines<br />

2187<br />

4<br />

1005<br />

drugs<br />

1<br />

3<br />

4<br />

2<br />

6<br />

5<br />

7<br />

8<br />

1. Amitriptyline<br />

2. Trimipramine<br />

3. Doxepin (cis-Doxepin)<br />

4. Imipramine<br />

5. Doxepin (trans-Doxepin)<br />

6. Desipramine<br />

7. Maprotyline<br />

8. Clomipramine<br />

1<br />

2<br />

3<br />

5<br />

6<br />

7<br />

1. Pheniramine<br />

2. Doxylamine<br />

3. Orphenadrine<br />

4. Methapyraline<br />

5. Chlorpheniramine<br />

6. Diphenylpyraline<br />

7. Promethazine<br />

0<br />

4 8 12 16 20 Min. 0 2 4 6 8 Min.<br />

Column: Econo-Cap AT-20, 30m x 0.32mm x 0.25µm<br />

(Part No. 19677)<br />

Temp: 235°C<br />

Carrier Gas: Helium at 22 cm/sec<br />

Detector: FID<br />

Antihistamines<br />

Column: Econo-Cap EC-1, 15m x 0.53mm x 1.20µm<br />

(Part No. 19650)<br />

Temp: 210°C<br />

Carrier Gas: Helium at 8.5mL/min<br />

Detector: FID<br />

Hypnotics<br />

2567<br />

4<br />

1009<br />

1<br />

3<br />

2<br />

4 5 6<br />

1. Pheniramine<br />

2. Doxylamine<br />

3. Orphenadrine<br />

4. Methapyraline<br />

5. Chlorpheniramine<br />

6. Diphenylpyraline<br />

2<br />

3<br />

5<br />

1. Trichloroethanol<br />

2. Allobarbital<br />

3. Butabarbital<br />

4. Secobarbital<br />

5. Methaqualone<br />

1<br />

0<br />

1 2 3 4 5 Min.<br />

0 2 4 6 8 10 12 14 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-5ms, 15m x 0.25mm x 0.25µm<br />

(Part No. 15801)<br />

210°C (1 min hold) to 230°C at 5°C/min<br />

Helium at 0.7mL/min (25cm/sec)<br />

FID<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Econo-Cap EC-1, 30m x 0.32mm x 0.25µm<br />

(Part No. 19651)<br />

160°C to 220°C at 10°C/min<br />

Helium at 1.08mL/min<br />

FID<br />

466<br />

www.discoverysciences.com


gc applications<br />

Fast GC Drug Analysis<br />

Fluoxetine and Metabolite<br />

<br />

<br />

<br />

<br />

1. Ethosuximide<br />

2. α-Methyl-α-propylsuccinimide<br />

3. Metharbital<br />

4. Barbital<br />

5. Methsuximide<br />

6. Phensuximide<br />

<br />

<br />

7. N-Normethsuximide<br />

8. Mephenytoin<br />

9. Ethotoin<br />

10. Mephobarbital<br />

11. 2-Ethyl-2-phenylmalonamide<br />

12. Phenobarbital<br />

13. Methyl PEMA<br />

2262 1786<br />

<br />

1. Norfluoxetine<br />

2. Fluoxetine<br />

<br />

<br />

Column: Heliflex ® AT-5, 20m x 0.10mm x 0.10µm<br />

(Part No. 14454)<br />

Temp: 240°C<br />

Carrier Gas: Helium at 0.1mL/min<br />

Detector: FID<br />

<br />

Column: Heliflex ® AT-1, 30m x 0.32mm x 0.25µm<br />

(Part No. 13640)<br />

Temp: 200°C<br />

Carrier Gas: Helium at 1.06mL/min<br />

Detector: FID<br />

Sedatives<br />

1<br />

2<br />

3<br />

9<br />

10<br />

11<br />

6<br />

4<br />

5 7 8<br />

12<br />

13<br />

14<br />

15<br />

1. Ethchlorvynol<br />

2. Ethinamate<br />

3. Methyprylon<br />

4. Aprobarbital<br />

5. Butalbital<br />

6. Amobarbital<br />

7. Pentobarbital<br />

8. Meprobamate<br />

9. Prazepam<br />

10. Hexobarbital<br />

11. Alphenal<br />

12. Methaqualone<br />

13. Halazepam<br />

14. Chlordiazepoxide<br />

15. Triazolam<br />

1003<br />

drugs<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 26 Min.<br />

Nitrazepam and ANB Metabolite<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Econo-Cap EC-1, 30m x 0.32mm x 0.25µm<br />

(Part No. 19651)<br />

160°C to 220°C at 10°C/min<br />

Helium at 1.08mL/min<br />

FID<br />

<br />

1. Nitrazepam<br />

2. 2-Amino-5-nitrobenzophenone<br />

2592<br />

<br />

<br />

<br />

Column: Heliflex ® AT-1ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15897)<br />

Temp: 280°C<br />

Carrier Gas: Helium at 0.7mL/min (25cm/sec)<br />

Detector: FID<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

467


gc applications<br />

Steroids<br />

1<br />

2 3<br />

4<br />

5<br />

6<br />

7<br />

Steroids, TMS Derivatives<br />

11<br />

10<br />

12<br />

0 2 4 6 8 10 12 14 Min.<br />

8<br />

9<br />

1. Androsterone<br />

2. Estrone<br />

3. Estradiol<br />

4. Testosterone<br />

5. Progesterone<br />

6. 5-α-Cholestane<br />

(underivatized)<br />

7. Estriol<br />

8. Coprostanol<br />

9. Cholesterol<br />

10. Campesterol<br />

11. Stigmasterol<br />

12. β-Sitosterol<br />

Column: Econo-Cap EC-1, 30m x 0.32mm x 0.25µm<br />

(Part No. 19651)<br />

Temp: 290°C<br />

Carrier Gas: Helium at 1.09mL/min<br />

Detector: FID<br />

1008<br />

1<br />

2 3<br />

4<br />

5<br />

Anabolic Steroids<br />

1. Nandrolone<br />

2. Testosterone<br />

3. Norethandrolone<br />

4. Clostebol<br />

5. Fluoxymesterone<br />

0 2 4 6 8 10 Min.<br />

Column: Econo-Cap EC-5, 30m x 0.25mm x 0.25µm<br />

(Part No. 19647)<br />

Temp: 300°C<br />

Carrier Gas: Helium at 0.65mL/min<br />

Detector: FID<br />

1019<br />

environmental<br />

Chlorinated Disinfection<br />

EPA Method 551: Chlorinated Disinfection<br />

<br />

Byproducts by NPD<br />

2280<br />

<br />

1. Trichloroacetonitrile<br />

2. Dichloroacetonitrile<br />

3. Bromochloroacetonitrile<br />

4. Dibromoacetonitrile<br />

<br />

<br />

Column: Heliflex ® AT-5, 30m x 0.32mm x 0.25µm<br />

(Part No. 13658)<br />

Temp:<br />

55°C (2 min hold) to 75°C at 5°C/min<br />

Carrier Gas: Helium at 2.2mL/min<br />

Detector: NPD<br />

Haloacetic Acids<br />

EPA Method 552.1: Haloacetic Acids<br />

1. Monochloroacetic Acid<br />

2. Monobromoacetic Acid<br />

3. Dalapon<br />

4. Dichloroacetic Acid<br />

5. Trichloroacetic Acid<br />

6. Bromochloroacetic Acid<br />

7. Dibromoacetic Acid<br />

0<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1<br />

4<br />

2<br />

3<br />

2 4 6 8 10 12 14 16 18 Min.<br />

Heliflex ® AT-1701, 30m x 0.32mm x 0.25µm<br />

(Part No. 13690)<br />

50°C (10 min hold) to 120°C at 10°C/min<br />

Helium at 35cm/sec<br />

ECD<br />

5<br />

6<br />

7<br />

2105<br />

Pesticides<br />

1 2 3<br />

4<br />

Carbamates<br />

1. Naled<br />

2. Metacil<br />

3. Zectran<br />

4. Carbaryl<br />

1232<br />

Organophosphorus Pesticides<br />

1. TEPP<br />

14. Carbophenothion<br />

2. Sulfotepp<br />

15. Phosmet<br />

3. Monocrotophos 16. EPN<br />

4. Dimethoate 17. Leptophos<br />

5. Dioxathion<br />

18. Azinphos-ethyl<br />

6. Terbufos<br />

2<br />

7. Phosphamidon<br />

4<br />

8. Malathion<br />

6<br />

9. Parathion<br />

10. cis-Chlorfenvinphos<br />

3<br />

11. trans-Chlorfenvinphos<br />

12. Ethion<br />

1<br />

13. Famphur<br />

5<br />

7<br />

8 9<br />

10<br />

11<br />

16<br />

12<br />

14<br />

13 15 17 18<br />

2469<br />

0 5 Min.<br />

Column: Heliflex ® AT-Pesticide, 20m x 0.53mm x 0.60µm<br />

(Part No. 16846)<br />

Temp: 200°C<br />

Carrier Gas: Helium at 7.5mL/min<br />

Detector: ECD<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

4 8 12 16 20 24 28 32 36 40 Min.<br />

Heliflex ® AT-5ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15807)<br />

120°C (3 min hold) to 285°C at 5°C/min<br />

Helium at 26cm/sec<br />

MSD<br />

468<br />

www.discoverysciences.com


gc applications<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Chlorinated and Organophosphorus Pesticides<br />

<br />

<br />

<br />

1. TEPP<br />

2. Monocrotophos<br />

3. α-BHC<br />

4. Sulfotep<br />

5. Dimethoate<br />

6. β-BHC<br />

7. γ-BHC<br />

8. δ-BHC<br />

9. Heptachlor<br />

10. Aldrin<br />

11. Malathion<br />

12. Parathion<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

13. Heptachlor Epoxide<br />

14. Endosulfan I<br />

15. Dieldrin<br />

16. p,p'-DDE<br />

17. Endrin<br />

18. Endosulfan II<br />

19. p,p'-DDD<br />

20. Endrin Aldehyde<br />

21. Endosulfan Sulfate<br />

22. p,p'-DDT<br />

23. EPN<br />

24. Methoxychlor<br />

Heliflex ® AT-5, 30m x 0.32mm x 0.25µm<br />

(Part No. 13658)<br />

100°C (2 min hold) to 280°C at 10°C/min<br />

Helium at 1mL/min<br />

NPD<br />

2315<br />

Chlorinated Pesticides<br />

2466<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1. Etridiazole<br />

2. Chloroneb<br />

3. Propachlor<br />

4. Trifluralin<br />

5. α-BHC<br />

6. β-BHC<br />

7. Pentachloronitro-benzene<br />

8. γ-BHC<br />

9. Diclone<br />

10. Chlorothalonil<br />

11. δ-BHC<br />

12. Alachlor<br />

13. Heptachlor<br />

14. Aldrin<br />

15. Dacathal<br />

16. Heptachlor Epoxide<br />

17. γ-Chlordane<br />

18. α-Chlordane<br />

19. Endosulfan I<br />

20. trans-Nonachlor<br />

21. p,p’-DDE<br />

22. Dieldrin<br />

23. Perthane<br />

24. Nitrofen<br />

25. Endrin<br />

26. Chloropropylate<br />

27. Endosulfan II<br />

28. p,p’-DDD<br />

29. Endrin Aldehyde<br />

30. p,p’-DDT<br />

31. Endosulfan Sulfate<br />

32. Captafol<br />

33. Endrin Ketone<br />

34. Methoxychlor<br />

35. Kelthane<br />

36. Mirex<br />

37. cis-Permethrin<br />

Column: Heliflex ® AT-5ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15807)<br />

Temp:<br />

80°C (1 min hold) to 100°C at 15°C/min, to 160°C at<br />

10°C/min, to 285°C at 5°C/min<br />

Carrier Gas: Helium at 26cm/sec<br />

Detector: MSD at 300°C<br />

environmental<br />

<br />

Pesticide Mix<br />

<br />

Chlorinated Pesticides<br />

<br />

<br />

<br />

<br />

<br />

1. Diazinon<br />

2. Dimethoate<br />

3. Lorsban<br />

4. Malathion<br />

5. Parathion<br />

6. Ethion<br />

1853<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1. α-BHC<br />

2. γ-BHC<br />

3. β-BHC<br />

4. δ-BHC<br />

1569<br />

5. Heptachlor<br />

6. Aldrin<br />

7. Heptachlor Epoxide<br />

8. Endosulfan I<br />

9. p,p'-DDE<br />

10. Dieldrin<br />

11. Endrin<br />

12. p,p’-DDD<br />

13. Endosulfan II<br />

14. p,p’-DDT<br />

15. Endrin Aldehyde<br />

16. Endosulfan Sulfate<br />

<br />

<br />

<br />

Column: Heliflex ® AT-Pesticide, 30m x 0.53mm x 0.60µm<br />

(Part No. 13969)<br />

Temp: 200°C<br />

Carrier Gas: Helium at 5mL/min (37.3cm/sec)<br />

Detector: ECD<br />

<br />

Column: Heliflex ® AT-Pesticide, 30m x 0.25mm x 0.25µm<br />

(Part No. 13662)<br />

Temp:<br />

190°C to 240°C at 3°C/min<br />

Carrier Gas: Helium at 0.65mL/min<br />

Detector: ECD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

469


gc applications<br />

Pesticides<br />

EPA Method 508 — Chlorinated Pesticides<br />

EPA Method 505 — Organohalide Pesticides<br />

(Chlordane) 1552 7 10<br />

8 11<br />

1612<br />

9 1. Hexachlorocyclopentadiene<br />

12<br />

2. Simazine<br />

3. Atrazine<br />

1<br />

5<br />

4<br />

2 3 6<br />

13<br />

14<br />

4. Hexachlorobenzene<br />

5. Lindane<br />

6. Alachlor<br />

7. Heptachlor<br />

8. Aldrin<br />

9. Heptachlor Epoxide<br />

10. γ-Chlordane<br />

11. α-Chlordane<br />

12. Dieldrin<br />

13. Endrin<br />

14. Methoxychlor<br />

<br />

0 4 8 12 16 20 24 28 32 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Econo-Cap EC-5, 30m x 0.32mm x 0.25µm<br />

(Part No. 19646)<br />

60°C to 300°C at 4°C/min<br />

Helium at 1.45mL/min<br />

ECD<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Econo-Cap EC-1, 30m x 0.32mm x 1.00µm<br />

(Part No. 19660)<br />

180°C to 260°C at 4°C/min<br />

Helium at 1.2mL/min<br />

ECD<br />

EPA Method 507, Nitrogen and Phosphorus Containing Pesticides by GC/NPD<br />

environmental<br />

1<br />

2<br />

4<br />

3<br />

5<br />

6<br />

7<br />

8 9 16<br />

15<br />

11 10<br />

17<br />

12<br />

0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 Min.<br />

14<br />

13 18<br />

23<br />

19<br />

20 22<br />

21 24<br />

25<br />

1. Dichlorvos<br />

2. EPTC<br />

3. Vernolate<br />

4. Pebulate<br />

5. Tebuthiuron<br />

6. Molinate<br />

7. Ethoprop<br />

8. Atraton<br />

9. Simazine<br />

10. Atrazine<br />

11. Propazine<br />

12. Terbufos<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

13. Pronamid<br />

14. Disulfoton<br />

15. Alachlor<br />

16. Ametryn<br />

17. Terbutryn<br />

18. Metolachlor<br />

19. MGK 264 (Peak 1)<br />

20. MGK 264 (Peak 2)<br />

21. Merphos (Peak 1)<br />

22. Butylate<br />

23. Napropamide<br />

24. Merphos (Peak 2)<br />

25. Fenarimol<br />

1551<br />

Econo-Cap EC-5, 30m x 0.32mm x 0.25µm<br />

(Part No. 19646)<br />

60°C to 300°C at 4°C/min<br />

Helium at 1.45mL/min<br />

NPD<br />

EPA Method 508 — Chlorinated Pesticides in Water<br />

1<br />

2<br />

3<br />

4<br />

5<br />

0 4 8 12 16 20 24 28 32 36 40 44 48 52 Min.<br />

6<br />

7<br />

8<br />

12 14<br />

9<br />

15<br />

11 13 16<br />

10<br />

20<br />

17<br />

18<br />

19<br />

21<br />

22<br />

23<br />

1. Propachlor<br />

2. Trifluralin<br />

3. α-HCH<br />

4. Hexachlorobenzene<br />

5. β-HCH<br />

6. γ-HCH<br />

7. δ-HCH<br />

8. Heptachlor<br />

9. Aldrin<br />

10. DCPA<br />

11. Heptachlor Epoxide<br />

12. γ-Chlordane<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

13. α-Chlordane<br />

14. Dieldrin<br />

15. p,p'-DDE<br />

16. Endrin<br />

17. p,p'-DDD<br />

18. Endrin Aldehyde<br />

19. Endosulfan Sulfate<br />

20. p,p'-DDT<br />

21. Methoxychlor<br />

22. cis-Permethrin<br />

23. trans-Permethrin<br />

1550<br />

Econo-Cap EC-5, 30m x 0.32mm x 0.25µm<br />

(Part No. 19646)<br />

60°C to 300°C at 4°C/min<br />

Helium at 1.45mL/min<br />

ECD<br />

470<br />

www.discoverysciences.com


gc applications<br />

<br />

Semivolatiles<br />

Column:<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1. Phenol<br />

2. 2-Chlorophenol<br />

3. 2-Nitrophenol<br />

4. 2,4-Dimethylphenol<br />

5. 2,4-Dichlorophenol<br />

Phenols<br />

6. 4-Chloro-3-Methylphenol<br />

7. 2,4,6-Trichlorophenol<br />

8. 2,4-Dinitrophenol<br />

9. 4-Nitrophenol<br />

10. 2-Methyl-4,6-Dinitrophenol<br />

11. Pentachlorophenol<br />

<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm<br />

(Part No. 13656)<br />

70°C (2 min hold) to 230°C at 8°C/min<br />

Helium at 0.8mL/min<br />

FID<br />

Phthalate and Adipate Esters<br />

2286<br />

<br />

<br />

<br />

<br />

1. 1,3-Dichlorobenzene<br />

2. 1,4-Dichlorobenzene<br />

3. 1,2-Dichlorobenzene<br />

4. Hexachloroethane<br />

<br />

<br />

<br />

Base/Neutral Mix<br />

<br />

5. Nitrobenzene<br />

2207<br />

6. Isophorone<br />

7. 1,2,4-Trichlorobenzene<br />

8. Hexachlorobutadiene<br />

9. Hexachlorocyclopentadiene<br />

10. 2-Chloronaphthalene<br />

11. 2,6-Dinitrotoluene<br />

12. 2,4-Dinitrotoluene<br />

13. Azobenzene<br />

14. Hexachlorobenzene<br />

<br />

Column: Heliflex ® AT-5, 30m x 0.32mm x 0.25µm<br />

(Part No. 13658)<br />

Temp:<br />

60°C (2 min hold) to 205°C at 8°C/min<br />

Carrier Gas: Helium at 2.2mL/min<br />

Detector: FID<br />

EPA Method 606 - Phthalates<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6 7<br />

5 10 15 20 25 30 35 40 45 Min.<br />

2104<br />

1. Dimethyl Phthalate<br />

2. Diethyl Phthalate<br />

3. Di-n-Butyl Phthalate<br />

4. Butylbenzyl Phthalate<br />

5. Di(2-ethylhexyl) Adipate<br />

6. Di(2-ethylhexyl) Phthalate<br />

7. Di-n-Octyl Phthalate<br />

Column: Heliflex ® AT-1, 30m x 0.32mm x 0.25µm<br />

(Part No. 13640)<br />

Temp:<br />

60°C (1 min hold) to 260°C at 6°C/min<br />

Carrier Gas: Helium at 32cm/sec<br />

Detector: FID at 295°C<br />

0<br />

Column:<br />

1<br />

2<br />

3<br />

4 8 12 16 20 24 28 Min.<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

4<br />

5<br />

6<br />

1. Dimethylphthalate (20ng)<br />

2. Diethylphthalate (20ng)<br />

3. Di-n-butylphthalate (20ng)<br />

4. Butylbenzyl Phthalate (20ng)<br />

5. Bis(2-ethylhexyl)phthalate (20ng)<br />

6. Di-n-octylphthalate (20ng)<br />

Heliflex ® AT-5, 15m x 0.53mm x 1.00µm<br />

(Part No. 13569)<br />

115°C (4 min hold) to 250°C at 10°C/min<br />

Helium at 3.4mL/min (35cm/sec)<br />

FID<br />

2583<br />

environmental<br />

EPA SW846 Method 8091<br />

Nitroaromatics and Cyclic Ketones<br />

EPA Method 612: Chlorinated Hydrocarbons<br />

2114<br />

1840<br />

1. Isophorone<br />

4. 2,6-Dinitrotoluene<br />

1 2 2. Nitrobenzene<br />

5. 1,3-Dinitrobenzene<br />

3. 1,4-Napthoquinone 6. 2,4-Dinitrotoluene<br />

3 4 6 5<br />

1 23 4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

1. 1,3-Dichlorobenzene<br />

2. 1,4-Dichlorobenzene<br />

3. 1,2-Dichlorobenzene<br />

4. Hexachloroethane<br />

5. 1,2,4-Trichlorobenzene<br />

6. Hexachlorobutadiene<br />

7. Hexachlorocyclopentadiene<br />

8. 2-Chloronaphthalene<br />

9. Hexachlorobenzene<br />

0 4 8 12 16 20 Min.<br />

Column: Heliflex ® AT-1701, 30m x 0.53mm x 1.00µm<br />

(Part No. 13795)<br />

Temp:<br />

120°C (2 min hold) to 200°C at 3°C/min<br />

Carrier Gas: Helium at 44.5cm/sec<br />

Detector: FID<br />

0 2 4 6 8 10 12 14 16 18 Min.<br />

Column: Heliflex ® AT-1301, 30m x 0.53mm x 1.00µm<br />

(Part No. 13970)<br />

Temp:<br />

90°C (4 min hold) to 190°C at 10°C/min<br />

Carrier Gas: Helium at 8.1mL/min<br />

Detector: FID<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

471


gc applications<br />

Semivolatiles<br />

EPA Method 610: Polynuclear Aromatic Hydrocarbons<br />

Fast PAH Analysis<br />

<br />

<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. Acenaphthene<br />

4. Fluorene<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

5. Phenanthrene 2208<br />

6. Anthracene<br />

7. Fluoranthene<br />

8. Pyrene<br />

9. Benz[a]anthracene<br />

10. Chrysene<br />

11. Benzo[b]fluoranthene<br />

12. Benzo[k]fluoranthene<br />

13. Benzo[a]pyrene<br />

14. Indeno[1,2,3-c,d]pyrene<br />

15. Dibenz[a,h]anthracene<br />

16. Benzo[g,h,i]perylene<br />

<br />

<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. Acenaphthene<br />

4. Fluorene<br />

5. Phenanthrene<br />

6. Anthracene<br />

<br />

<br />

<br />

<br />

<br />

<br />

7. Fluoranthene<br />

2284<br />

8. Pyrene<br />

9. Benz[a]anthracene<br />

10. Chrysene<br />

11. Benzo[b]fluoranthene<br />

12. Benzo[k]fluoranthene<br />

13. Benzo[a]pyrene<br />

14. Indeno[1,2,3-c,d]pyrene<br />

15. Dibenz[a,h]anthracene<br />

16. Benzo[g,h,i]perylene<br />

<br />

Column: Heliflex ® AT-5, 30m x 0.32mm x 0.25µm<br />

Column: Heliflex ® AT-5, 10m x 0.10mm x 0.10µm<br />

(Part No. 13658)<br />

(Part No. 14438)<br />

Temp:<br />

60°C (2 min hold) to 315°C at 8°C/min<br />

Temp:<br />

100°C to 340°C at 20°C/min<br />

Carrier Gas: Helium at 1.6mL/min<br />

Carrier Gas: Helium at 0.1mL/min (25 cm/sec)<br />

Detector: FID<br />

Detector: FID<br />

environmental<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

PAHs<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. Acenaphthene<br />

4. Fluorene<br />

5. Phenanthrene<br />

6. Anthracene<br />

7. Fluoranthene<br />

8. Pyrene<br />

9. Benz[a]anthracene<br />

10. Chrysene<br />

11. Benzo[b]fluoranthene<br />

12. Benzo[k]fluoranthene<br />

13. Benzo[a]pyrene<br />

14. Indeno[1,2,3-c,d]pyrene<br />

15. Dibenz[a,h]anthracene<br />

16. Benzo[g,h,i]perylene<br />

Heliflex ® AT-5ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15807)<br />

80°C (1 min hold) to 160°C at 25°C/min,<br />

to 300°C at 3°C min,<br />

to 325°C at 25°C/min<br />

Helium at 0.8mL/min (26cm/sec)<br />

FID<br />

2463<br />

Phenols Mix on AT-1ms<br />

2621<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1. Phenol<br />

2. 2-Chlorophenol<br />

3. o-Cresol<br />

4. m & p-Cresol<br />

5. 2-Nitrophenol<br />

6. 2,4-Dimethylphenol<br />

7. 2,4-Dichlorophenol<br />

8. 2,6-Dichlorophenol<br />

9. 4-Chloro-3-methylphenol<br />

10. 2,4,6-trichlorophenol<br />

11. 2,4,5-Trichlorophenol<br />

12. 2,4-Dinitrophenol<br />

13. 4-Nitrophenol<br />

14. 2,3,4,6-Tetrachlorophenol<br />

15. 2-Methyl-4,6-dinitrophenol<br />

16. Pentachlorophenol<br />

Column: Heliflex ® AT-1ms, 30m x 0.25mm x 0.25μm<br />

(Part No. 15897)<br />

Temp:<br />

60°C (0.5 min hold) to 235°C at 10°C/min<br />

Carrier:<br />

Helium at 1mL/min (28cm/sec)<br />

Detector: FID at 340°C<br />

472<br />

www.discoverysciences.com


gc applications<br />

Volatiles<br />

5,6<br />

Aromatic Solvents<br />

1<br />

2<br />

4<br />

3<br />

7<br />

8<br />

9<br />

10<br />

11<br />

1. Benzene<br />

2. Toluene<br />

3. Chlorobenzene<br />

4. Ethylbenzene<br />

5. m-Xylene<br />

6. p-Xylene<br />

7. o-Xylene<br />

8. 1,4-Dichlorobenzene<br />

9. 1,2-Dichlorobenzene<br />

10. 1,2,4-Trichlorobenzene<br />

11. Napthalene<br />

12. 1,2,3-Trichlorobenzene<br />

2588<br />

12<br />

0<br />

2 4 6 8 10 12 14 16 18 20 22 24 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-5, 30m x 0.32mm x 1.00µm<br />

(Part No. 13659)<br />

60°C (4 min hold) to 200°C at 10°C/min<br />

Helium at 1.3mL/min (24cm/sec)<br />

FID<br />

1 7<br />

OSHA Method 07: Organic Vapors<br />

2589<br />

0<br />

3<br />

2<br />

5<br />

6<br />

4<br />

8<br />

9<br />

11,12<br />

10<br />

13<br />

14<br />

15<br />

2 4 6 8 10 12 14 16 18 20 22 Min.<br />

16<br />

17<br />

18<br />

19<br />

20<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1. Pentane<br />

2. Hexane<br />

3. Isopropyl Ether<br />

4. Isooctane<br />

5. Heptane<br />

6. Cyclohexane<br />

7. Carbon Disulfide<br />

8. Methylcyclohexane<br />

9. trans-1,2-Dichloroethene<br />

10. Ethyl Acetate<br />

11. tert-Butyl Alcohol<br />

12. Isopropyl Acetate<br />

13. Propyl Acetate<br />

14. cis-1,2-Dichloroethene<br />

15. Isobutyl Acetate<br />

16. 1,4-Dioxane<br />

17. Butyl Acetate<br />

18. 2-Butanol<br />

19. Cumene<br />

20. Chlorobenzene<br />

Heliflex ® AT-Wax, 30m x 0.32mm x 1.00µm<br />

(Part No. 137382)<br />

40°C (4 min hold) to 140°C at 5°C/min<br />

Helium at 1.4mL/min (25cm/sec)<br />

FID<br />

environmental<br />

1 3<br />

2<br />

7<br />

5<br />

6 9<br />

8<br />

10,11<br />

16<br />

12 13<br />

15<br />

14<br />

17<br />

18<br />

19<br />

OSHA Method 07: Organic Vapors<br />

20<br />

1. Pentane<br />

2. tert-Butyl Alcohol<br />

3. Carbon Disulfide<br />

4. trans-1,2-Dichloroethene<br />

5. Hexane<br />

6. Isopropyl Ether<br />

7. cis-1,2-Dichloroethene<br />

8. Ethyl Acetate<br />

9. 2-Butanol<br />

10. Cyclohexane<br />

11. Isopropyl Acetate<br />

12. Isooctane<br />

13. Heptane<br />

14. 1,4-Dioxane<br />

15. Propyl Acetate<br />

16. Methylcyclohexane<br />

17. Isobutyl Acetate<br />

18. Butyl Acetate<br />

19. Chlorobenzene<br />

20. Cumene<br />

2590<br />

0<br />

4<br />

2 4 6 8 10 12 14 16 18 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-5, 30m x 0.32mm x 1.00µm<br />

(Part No. 13659)<br />

40°C (4 min hold) to 160°C at 5°C/min<br />

Helium at 1.45mL/min (24cm/sec)<br />

FID<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

473


gc applications<br />

Volatiles<br />

4<br />

5<br />

3<br />

12<br />

6<br />

7<br />

EPA Method 601 —<br />

EPA Method 602 —<br />

1 7<br />

Purgeable Halocarbons 1132 2 3 4<br />

5 Purgeable Aromatics<br />

1138<br />

1. Methyl Chloride<br />

2. Vinyl Chloride<br />

3. Dichlorofluoromethane<br />

4. Methyl Bromide<br />

5. Ethyl Chloride<br />

6. Trichlorofluoromethane<br />

7. Methylene Chloride<br />

6<br />

1. Benzene<br />

2. Toluene<br />

3. Ethylbenzene<br />

4. Chlorobenzene<br />

5. 1,3-Dichlorobenzene<br />

6. 1,4-Dichlorobenzene<br />

7. 1,2-Dichlorobenzene<br />

0 2 4 6 8 10 Min.<br />

Column: Heliflex ® AT-1, 30m x 0.53mm x 5.00µm<br />

(Part No. 16843)<br />

Temp: 35°C<br />

Carrier Gas: Helium at 3mL/min<br />

Detector: FID<br />

0 3 6 9 12 15 Min.<br />

Column: Heliflex ® AT-WAX, 15m x 0.53mm x 5.00µm<br />

(Part No. 16883)<br />

Temp:<br />

55°C to 150°C at 8°C/min<br />

Carrier Gas: Helium at 7mL/min<br />

Detector: FID<br />

Halocarbons<br />

8<br />

1133<br />

environmental<br />

1. 1,1-Dichloroethane<br />

2. Chloroform<br />

3. 1,2-Dichloroethane<br />

4. 1,1,1-Trichloroethane<br />

5. Carbon Tetrachloride<br />

6. 1,2-Dichloropropane<br />

7. Bromodichloromethane<br />

+ Trichloroethene<br />

8. 2-Chloroethyl Vinyl Ether<br />

9. trans-1,3-Dichloropropene<br />

10. cis-1,3-Dichloropropene<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

11. 1,2,2-Trichloroethane<br />

12. Dibromochloromethane<br />

13. Tetrachloroethene<br />

14. Chlorobenzene<br />

15. Bromoform<br />

16. 1,1,2,2-Tetrachloroethane<br />

17. m-Dichlorobenzene<br />

18. p-Dichlorobenzene<br />

19. o-Dichlorobenzene<br />

Heliflex ® AT-1, 30m x 0.53mm x 5.00µm<br />

(Part No. 16843)<br />

40°C (5 min hold) to 200°C/min at 5°C/min<br />

Helium at 3mL/min<br />

FID<br />

1<br />

2<br />

3 4<br />

5<br />

6 7 9<br />

11<br />

10<br />

0 5 10 15 20 25 30 Min.<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17 19 18<br />

12<br />

18<br />

Priority Pollutant Analysis<br />

1234<br />

21 23<br />

9<br />

13<br />

17<br />

22<br />

15<br />

11<br />

10 12 16<br />

14<br />

5 7<br />

20<br />

3<br />

19<br />

4 6<br />

8<br />

0 4 8 12 16 20 24 28 Min.<br />

1. Methane<br />

2. Chloromethane<br />

3. Chloroethane<br />

4. Methylene Chloride<br />

5. Bromochloromethane<br />

6. Chloroform<br />

7. 1,1,1-Trichloroethane<br />

8. Carbon Tetrachloride<br />

9. 1,2-Dichloroethane<br />

10. Trichloroethylene<br />

11. 1,2-Dichloropropane<br />

12. Bromodichloromethane<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

13. cis-1,3-Dichloropropene<br />

14. trans-1,3-Dichloropropene<br />

15. 1,1,2-Trichloroethane<br />

16. Tetrachloroethene<br />

17. Chlorodibromomethane<br />

18. Chlorobenzene<br />

19. Bromoform<br />

20. 1,1,2,2-Tetrachloroethane<br />

21. m-Dichlorobenzene<br />

22. p-Dichlorobenzene<br />

23. o-Dichlorobenzene<br />

Heliflex ® AT-624, 30m x 0.53mm x 3.00µm<br />

(Part No. 16889)<br />

35°C (5 min hold) to 140°C at 5°C/min<br />

Helium at 5mL/min<br />

FID<br />

474<br />

www.discoverysciences.com


gc applications<br />

EPA Method 624 — Purge & Trap Volatiles<br />

1660<br />

1. Chloromethane<br />

2. Vinyl Chloride<br />

3. Bromomethane<br />

4. Chloroethane<br />

5. Trichlorofluoromethane<br />

6. 1,1-Dichloroethane<br />

7. Methylene Chloride<br />

8. trans-1,2-Dichloroethane<br />

9. 1,1-Dichloroethane<br />

10. Chloroform<br />

11. 1,1,1-Trichloroethane<br />

12. Carbon Tetrachloride<br />

13. Benzene<br />

14. 1,2-Dichloroethane<br />

15. Trichloroethene<br />

16. 1,2-Dichloropropane<br />

17. Bromodichloromethane<br />

18. cis-1,3-Dichloropropene<br />

19. Toluene<br />

20. trans-1,3-Dichloropropene<br />

21. Tetrachloroethene + 1,1,2-Trichloroethane<br />

22. Dibromochloromethane<br />

23. Chlorobenzene<br />

24. Ethylbenzene<br />

25. Bromoform<br />

26. 1,1,2,2-Tetrachloroethane<br />

27. m-Dichlorobenzene<br />

28. p-Dichlorobenzene<br />

29. o-Dichlorobenzene<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Column: Heliflex ® AT-624, 60m x 0.53mm x 3.00µm, (Part No. 13800)<br />

Temp:<br />

35°C (10 min hold) to 155°C at 4°C/min<br />

Carrier Gas: Helium at 8mL/min<br />

Sample: 200ppb in 5mL H20<br />

Trap:<br />

Purge 11 min at 35mL/min, Desorb at 275°C for 4 min<br />

Detector: MSD<br />

<br />

<br />

<br />

environmental<br />

NIOSH 1450 — Acetates<br />

TCLP Volatiles Mix<br />

2<br />

1<br />

3 4 56<br />

7<br />

8 9 10<br />

1. Ethyl Acetate<br />

2. tert-Butyl acetate<br />

3. Propyl Acetate<br />

4. sec-Butyl acetate<br />

5. Ethyl Acrylate<br />

6. Isobutyl Acetate<br />

7. Butyl Acetate<br />

8. Isoamyl Acetate<br />

9. Amyl Acetate<br />

10. 2-Ethoxyethyl Acetate<br />

2591<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

1. Vinyl Chloride<br />

2. 1,1-Dichloroethene<br />

3. 2-Butanone<br />

4. Chloroform<br />

5. Carbon Tetrachloride<br />

6. Benzene + 1,2-Dichloroethene<br />

7. Trichloroethene<br />

8. Tetrachloroethene<br />

9. Chlorobenzene<br />

10. 1, 4-Dichlorobenzene<br />

2064<br />

0<br />

2 4 6 8 10 12 14 16 18 Min.<br />

0<br />

3 6 9 12 15 18 21 24 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-Wax, 30m x 0.32mm x 1.00µm<br />

(Part No. 137382)<br />

40°C (5 min hold) to 180°C at 10°C/min<br />

Helium at 1.6mL/min (28cm/sec)<br />

FID<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-502.2, 30m x 0.53mm x 3.00µm<br />

(Part No. 13792)<br />

40°C (10min hold) to 120°C at 4°C/min<br />

Helium at 22cm/sec<br />

FID<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

475


gc applications<br />

Volatiles<br />

EPA Method 602 — Purgeable Aromatics<br />

<br />

<br />

<br />

<br />

<br />

<br />

1233<br />

1. Benzene<br />

2. Toluene<br />

3. Chlorobenzene<br />

4. Ethylbenzene<br />

5. 1,3-Dichlorobenzene<br />

6. 1,4-Dichlorobenzene<br />

7. 1,2-Dichlorobenzene<br />

UST<br />

<br />

<br />

1. n-Octane<br />

2. n-Decane<br />

3. n-Dodecane<br />

4. n-Tetradecane<br />

TRPH Standard (Florida)<br />

5. n-Hexadecane<br />

6. n-Octadecane<br />

7. n-Eicosane<br />

8. n-Docosane<br />

<br />

<br />

<br />

<br />

2622<br />

9. n-Tetracosane<br />

10. n-Hexacosane<br />

11. n-Octacosane<br />

12. n-Triacontane<br />

13. n-Dotriacontane<br />

14. n-Tetratriacontane<br />

15. n-Hexatriacontane<br />

16. n-Octatriacontane<br />

17. n-Tetracontane<br />

<br />

Column: Heliflex ® AT-624, 30m x 0.32mm x 1.80µm<br />

(Part No. 13756)<br />

Temp:<br />

90°C (7 min hold) to 180°C at 10°C/min<br />

Carrier Gas: Helium at 1.1mL/min<br />

Detector: FID<br />

<br />

Column: Heliflex ® AT-1ht, 15m x 0.25mm x 0.10μm<br />

(Part No. 16367)<br />

Temp:<br />

75°C (1 min hold) to 340°C at 15°C/min<br />

Carrier:<br />

Helium at 1mL/min (33cm/sec)<br />

Detector: FID at 350°C<br />

Free Fatty Acids<br />

1<br />

2<br />

3<br />

Free Fatty Acids<br />

4 5<br />

6<br />

1. Propionic Acid<br />

2. Butyric Acid<br />

3. Valeric Acid<br />

4. Caproic Acid<br />

5. Heptanoic Acid<br />

6. Caprylic Acid<br />

3<br />

4 5 Short Chain Free Fatty Acids<br />

2528 1808<br />

2<br />

1. Acetic Acid<br />

1 6<br />

7<br />

2. Propionic Acid<br />

3. Isobutyric Acid<br />

8<br />

4. n-Butyric Acid<br />

5. Isovaleric Acid<br />

6. n-Valeric Acid<br />

7. Caproic Acid<br />

8. Heptanoic Acid<br />

foods, flavors, & fragrances<br />

0<br />

<br />

<br />

<br />

2 4 6 8 10 Min.<br />

Column: Heliflex ® AT-AquaWax-DA, 30m x 0.25mm x 0.25µm<br />

(Part No. 14537)<br />

Temp: 180°C<br />

Carrier Gas: Helium at 22cm/sec<br />

Detector: FID<br />

<br />

C1-C3 Acids (Aqueous)<br />

1. Water<br />

2. Formic Acid<br />

3. Acetic Acid<br />

4. Propionic Acid<br />

1072<br />

0 3 6 9 Min.<br />

Column: Econo-Cap EC-1000, 15m x 0.53mm x 1.20µm<br />

(Part No. 19684)<br />

Temp: 150°C<br />

Carrier Gas: Helium at 5mL/min<br />

Detector: FID<br />

1 2<br />

3<br />

4<br />

5<br />

Low Molecular Weight Acids<br />

6<br />

7<br />

8<br />

1. Formic Acid<br />

2. Acetic Acid<br />

3. Propionic Acid<br />

4. Isobutyric Acid<br />

5. Butyric Acid<br />

6. Isovaleric Acid<br />

7. Lactic Acid<br />

8. Valeric Acid<br />

1801<br />

<br />

Column: 6ft x 2mm i.d., Glass<br />

Packing: Porapak ® QS, 80/100 (Part No. 2719)<br />

Temp: 175°C<br />

Carrier Gas: Helium at 25mL/min<br />

Detector: TCD<br />

0 4 8 12 16 20 Min.<br />

Column: 2m x 2mm i.d., Glass<br />

Packing: 4% Carbowax ® 20M on Carbograph 1-DA,<br />

80/120 (Part No. 17271)<br />

Temp: 180°C<br />

Carrier Gas: Nitrogen at 20mL/min<br />

Detector: FID<br />

476<br />

www.discoverysciences.com


gc applications<br />

Alcohols<br />

The Glenlivet ® Scotch<br />

2525<br />

3<br />

6,7<br />

Red Wine Spiked with Off Flavor<br />

2539<br />

2<br />

1<br />

4<br />

5<br />

8 9<br />

1. Ethyl Acetate<br />

2. Methanol<br />

3. Ethanol<br />

4. 1-Propanol<br />

5. Isobutanol<br />

6. 2-Methyl-1-butanol<br />

7. 3-Methyl-1-butanol<br />

8. 4-Ethylguaiacol<br />

9. 4-Ethylphenol<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Heliflex ® AT-AquaWax, 60m x 0.25mm x 0.25µm<br />

(Part No. 12447)<br />

Temp:<br />

40°C (1 min hold) to 100°C at 30°C/min, then to<br />

200°C at 5°C/min<br />

Carrier Gas: Helium at 22cm/sec<br />

Detector: FID<br />

<br />

<br />

<br />

Column:<br />

<br />

<br />

<br />

<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

<br />

<br />

<br />

<br />

<br />

Scotch Whiskey<br />

<br />

<br />

<br />

1. Acetaldehyde<br />

2. Ethyl Acetate<br />

3. Methanol<br />

4. Ethanol<br />

5. n-Propanol<br />

6. Isobutanol<br />

7. Amyl Alcohol<br />

8. Isoamyl Alcohol<br />

9. Acetic Acid<br />

Econo-Cap EC-Wax, 15m x 0.53mm x 1.20µm<br />

(Part No. 19653)<br />

40°C (3 min hold) to 150°C at 25°C.min<br />

Helium at 3mL/minute<br />

FID<br />

Scotch Whiskey<br />

1. Acetaldehyde<br />

2. Methanol<br />

3. Ethanol<br />

4. Ethyl Acetate<br />

5. n-Propanol<br />

6. Isobutanol<br />

7. Pentanol<br />

8. Isopentanol<br />

9. Acetic Acid<br />

2035<br />

1818<br />

0<br />

1<br />

2<br />

3<br />

5 10 15 20 25 30 35 40 45 50 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

4<br />

5 7 8 9<br />

6<br />

10<br />

11<br />

12<br />

13<br />

Heliflex ® AT-AquaWax-DA, 60m x 0.25mm x 0.25µm<br />

(Part No. 14547)<br />

35°C (10 min hold) to 220°C at 6°C/min<br />

Helium at 25cm/sec<br />

FID<br />

1. Methanol<br />

2. Ethanol<br />

3. 2-Propanol<br />

4. 1-Propanol<br />

5. 2-Methyl-2-propanol<br />

6. 2-Butanol<br />

7. 2-Methyl-1-propanol<br />

14 15<br />

16<br />

0 2 4 6 8 10 Min.<br />

C1-C5 Alcohols<br />

8. 1-Butanol<br />

9. 2-Methyl-2-butanol<br />

10. 2,2-Dimethyl-1-propanol<br />

11. 3-Methyl-2-butanol<br />

12. 3-Pentanol<br />

13. 2-Pentanol<br />

14. 2-Methyl-1-butanol<br />

15. 3-Methyl-1-butanol<br />

16. 1-Pentanol<br />

Column: 6ft x 2mm i.d., Glass, 0.2% Carbowax ® 1500<br />

Packing: Carbograph 2, 60/80 (Part No. 1725)<br />

Temp: 130°C<br />

Carrier Gas: Nitrogen at 20mL/min<br />

Detector: FID<br />

Irish Whiskey<br />

1815<br />

2524<br />

foods, flavors, & fragrances<br />

<br />

Column: 2m x 2mm i.d., Glass<br />

Packing: Carbograph 1 AW 20, 80/120<br />

Temp:<br />

70°C to 170°C at 4°C/min<br />

Carrier Gas: Nitrogen at 20mL/min<br />

Detector: FID<br />

<br />

Column: Heliflex ® AT-AquaWax, 60m x 0.25mm x 0.25µm<br />

(Part No. 12447)<br />

Temp:<br />

40°C (1 min hold) to 100°C at 30°C/min, then to<br />

200°C at 5°C/min<br />

Carrier Gas: Helium at 22cm/sec<br />

Detector: FID at 275°C<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

477


gc applications<br />

Amino Acids<br />

N(O,S)-Heptafluorobutyl-isobutyl Esters of Amino Acids from Soy Protein Hydrolysate<br />

1241<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1. Alanine<br />

2. Glycine<br />

3. Valine<br />

4. Threonine<br />

5. Serine<br />

6. Leucine<br />

7. Isoleucine<br />

8. Proline<br />

9. Cystine<br />

10. Methionine<br />

11. Aspartic Acid<br />

12. Phenylalanine<br />

13. Glutamic Acid<br />

14. Lysine<br />

15. Tyrosine<br />

16. Arginine<br />

17. Histidine<br />

18. Tryptophan<br />

<br />

<br />

<br />

<br />

<br />

<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-Amino Acid, 25m x 0.53mm x 1.20µm<br />

(Part No. 16864)<br />

80°C (2 min hold) to 230°C at 4°C/min<br />

Helium at 10mL/min<br />

FID<br />

foods, flavors, & fragrances<br />

Antioxidants<br />

0 1<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Phenolic Antioxidants<br />

1<br />

3<br />

2<br />

4<br />

1. BHA<br />

2. BHT<br />

3. TBHQ<br />

4. 3,5-Di-tert-butyl-4-<br />

Hydroxybenzyl Alcohol<br />

5. THBP<br />

6. Propyl Gallate<br />

2 3 4 5 6 Min.<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm<br />

(Part No. 13656)<br />

220°C (3 min hold) to 265°C at 15°C/min<br />

Helium at 0.74mL/min<br />

FID<br />

5<br />

6<br />

2264<br />

Essential Oils<br />

2<br />

1<br />

3<br />

4<br />

56<br />

7<br />

8<br />

10<br />

9 11<br />

12<br />

13<br />

14<br />

0 5 10 15 20 25 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Aroma Test Mix<br />

1. trans-2-Hexenal<br />

2. p-Cymene<br />

3. cis-3-Hexenol<br />

4. trans-2-Hexenol<br />

5. Ethyl Octanoate<br />

6. 1-Octene-3-ol<br />

7. Benzaldehyde<br />

Heliflex ® AT-1000, 10m x 0.25mm x 0.20µm<br />

(Part No. 972510)<br />

50°C to 120°C at 3°C/min<br />

Hydrogen at 2.5mL/min<br />

FID<br />

1304<br />

8. Pentadecane<br />

9. Linalool<br />

10. Acetophenone<br />

11. Carvone<br />

12. Hexadecane<br />

13. Methyl Salicylate<br />

14. Benzyl Alcohol<br />

478<br />

www.discoverysciences.com


gc applications<br />

Essential Oils<br />

1 2 3 4<br />

5<br />

Citrus Reference Mix Peppermint Oil<br />

1311 2529<br />

6<br />

7 8<br />

9<br />

10<br />

1. α-Pinene<br />

2. Camphene<br />

3. β-Pinene<br />

4. p-Cymene<br />

5. Limonene<br />

6. Nonanal + Linalool<br />

7. Terpen-4-ol<br />

8. γ-Terpineol<br />

9. Neryl Acetate<br />

10. Geranyl Acetate<br />

0 2 4 6 8 10 Min.<br />

Column: Heliflex ® AT-1, 10m x 0.53mm x 1.20µm<br />

(Part No. 935110)<br />

Temp:<br />

75°C (5 min hold) to 150°C at 10°C/min<br />

Carrier Gas: Helium at 5mL/min<br />

Detector: FID<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Column: Heliflex ® AT-AquaWax, 30m x 0.25mm x 0.25µm<br />

(Part No. 12437)<br />

Temp:<br />

75°C to 260°C at 5°C/min<br />

Carrier Gas: Helium at 22cm/sec<br />

Detector: FID<br />

<br />

FAMEs<br />

1<br />

2<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

4 5<br />

3<br />

C14:0-C24:0 Fatty Acid Methyl Esters<br />

6<br />

7<br />

9<br />

8<br />

10<br />

1317<br />

1. Methyl Myristate (C14:0)<br />

2. Methyl Palmitate (C16:0)<br />

3. Methyl Stearate (C18:0)<br />

4. Methyl Oleate (C18:1 cis)<br />

5. Methyl Linoleate (C18:2 cis,cis)<br />

6. Methyl Linolenate (C18:3 cis,cis,cis)<br />

7. Methyl Arachidate (C20:0)<br />

8. Methyl Behenate (C22:0)<br />

9. Methyl Erucate (C22:1 cis)<br />

10. Methyl Lignocerate (C24:0)<br />

Lemon Oil<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

<br />

1. α-Thujene<br />

2. α-Pinene<br />

3. Camphene<br />

4. Sabinene<br />

5. β-Pinene<br />

6. 6-Methyl-5-hepten-2-one<br />

7. Myrcene<br />

8. Octanol<br />

9. α-Phellandrene<br />

10. 3-Carene<br />

11. α-Terpinene<br />

12. p-Cymene<br />

13. Limonene<br />

14. γ-Terpinene<br />

<br />

<br />

<br />

<br />

<br />

2288<br />

15. Terpindene<br />

16. Linalool<br />

17. Nonanal<br />

18. Citronellal<br />

19. Terpinen-4-ol<br />

20. α-Terpineol<br />

21. Neral<br />

22. Gerinal<br />

23. Neryl Acetate<br />

24. Geranyl Acetate<br />

25. β-Caryophyllene<br />

26. trans-α-Bergamotene<br />

27. β-Bisabolene<br />

Heliflex ® AT-5, 30m x 0.25mm x 0.25µm<br />

(Part No. 13656)<br />

70°C (2 min hold) to 200°C at 8°C/min<br />

Helium at 0.8mL/min<br />

FID<br />

Canola Oil<br />

2333<br />

1. Methyl Myristate (C14:0)<br />

2. Methyl Palmitate (C16:0)<br />

3. Methyl Palmitoleate (C16:1 cis)<br />

4. Methyl Stearate (C18:0)<br />

5. Methyl Oleate (C18:1 cis)<br />

6. Methyl Linoleate (C18:2 cis,cis)<br />

7. Methyl Linolenate<br />

(C18:3 cis,cis,cis)<br />

8. Methyl Arachidate (C20:0)<br />

foods, flavors, & fragrances<br />

0 4 8 12 16 Min. <br />

Column: Heliflex ® AT-Wax, 25m x 0.25mm x 0.20µm<br />

Column: Econo-Cap EC-Wax, 30m x 0.25mm x 0.25µm<br />

(Part No. 9925252)<br />

(Part No. 19655)<br />

Temp:<br />

180°C to 240°C at 5°C/min<br />

Temp:<br />

150°C (2 min hold) to 225°C at 5°C/min<br />

Carrier Gas: Hydrogen at 0.8mL/min<br />

Carrier Gas: Helium at 0.68mL/min<br />

Detector: FID<br />

Detector: FID<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

479


gc applications<br />

FAMEs<br />

2<br />

3<br />

5<br />

6<br />

7<br />

8<br />

13<br />

9 12<br />

10 11<br />

15<br />

16<br />

17<br />

PUFA (Animal Source)<br />

1. C14:0<br />

2. C16:0<br />

3. C16:1 ω7<br />

4. C18:0<br />

5. C18:1 ω9<br />

6. C18:1 ω7<br />

7. C18:2 ω6<br />

8. C18:3 ω3<br />

9. C20:1 ω11<br />

10. C20:1 ω9<br />

11. C20:2 ω6<br />

12. C20:3 ω6<br />

13. C20:4 ω6<br />

14. C20:5 ω3<br />

15. C22:4 ω6<br />

16. C22:5 ω3<br />

17. C22:6 ω3<br />

1845<br />

1<br />

14<br />

4<br />

0 5 10 15 20 25 30 35 40 45 50 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-Wax, 30m x 0.25mm x 0.25µm<br />

(Part No. 136462)<br />

160°C to 250°C at 2°C/min<br />

Helium at 0.65mL/min<br />

FID<br />

foods, flavors, & fragrances<br />

1 3 5 6 8 12 19 20<br />

<br />

<br />

2<br />

4<br />

7<br />

23<br />

9 1011<br />

18<br />

17<br />

22<br />

16<br />

14<br />

13 21<br />

15<br />

0 5 10 15 20 25 30 35 40 45 50 Min.<br />

Corn Oil<br />

PUFA (Marine Source)<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1. C14:0<br />

2. C16:0<br />

3. C16:1 ω7<br />

4. C16:4 ω1<br />

5. C18:1 ω9<br />

6. C18:1 ω7<br />

7. C18:1 ω5<br />

8. C18:2 ω6<br />

9. C18:3 ω3<br />

10. C18:4 ω3<br />

11. C20:1 ω11<br />

12. C20:1 ω9<br />

13. C20:1 ω7<br />

14. C20:2 ω6<br />

15. C20:3 ω6<br />

16. C20:4 ω6<br />

Heliflex ® AT-Wax, 30m x 0.25mm x 0.25µm<br />

(Part No. 136462)<br />

160°C to 250°C at 2°C/min<br />

Helium at 0.65mL/min<br />

FID<br />

Safflower Oil<br />

1580 1 23 4<br />

2517<br />

1844<br />

17. C20:3 ω3<br />

18. C20:4 ω3<br />

19. C22:1 ω11<br />

20. C22:1 ω9<br />

21. C21:5 ω3<br />

22. C22:5 ω3<br />

23. C22:6 ω3<br />

<br />

1. Methyl Palmitate [C16:0]<br />

2. Methyl Stearate [C18:0]<br />

3. Methyl Oleate [C18:1 cis]<br />

4. Methyl Linoleate [C18:2 cis,cis]<br />

5. Methyl Linolenate [C18:3 cis,cis,cis]<br />

1. C16:0 Methyl Ester<br />

2. C18:0 Methyl Ester<br />

3. C18:1 Methyl Ester<br />

4. C18:2 Methyl Ester<br />

<br />

<br />

<br />

0<br />

3 6 9 12 15 Min.<br />

Column: Econo-Cap EC-Wax, 30m x 0.32mm x 0.25µm<br />

(Part No. 19654)<br />

Temp: 220°C<br />

Carrier Gas: Helium at 1.09mL/min<br />

Detector: FID<br />

Column: Heliflex ® AT-FAME, 30m x 0.25mm x 0.25µm<br />

(Part No. 12436)<br />

Temp: 220°C<br />

Carrier Gas: Helium at 23cm/sec<br />

Detector: FID<br />

480<br />

www.discoverysciences.com


gc applications<br />

FAMEs<br />

1<br />

3<br />

4 5<br />

Sesame Oil<br />

1. Methyl Palmitate [C16:0]<br />

2. Methyl Palmitoleate [C16:1]<br />

3. Methyl Stearate [C18:0]<br />

4. Methyl Oleate [C18:1 cis]<br />

5. Methyl Linoleate [C18:2 cis,cis]<br />

6. Methyl Linolenate [C18:3 cis,cis,cis]<br />

1575<br />

<br />

<br />

<br />

<br />

Olive Oil<br />

1. Methyl Palmitate [C16:0]<br />

2. Methyl Palmitoleate [C16:1]<br />

3. Methyl Stearate [C18:0]<br />

4. Methyl Oleate [C18:1 cis]<br />

5. Methyl Linoleate [C18:2 cis,cis]<br />

6. Methyl Linolenate [C18:3 cis,cis,cis]<br />

1012<br />

2<br />

6<br />

<br />

<br />

0 2 4 6 8 10 Min.<br />

Column: Econo-Cap EC-Wax, 30m x 0.25mm x 0.25µm<br />

(Part No. 19655)<br />

Temp: 220°C<br />

Carrier Gas: Helium at 0.67mL/min<br />

Detector: FID<br />

<br />

Column: Econo-Cap EC-Wax, 30m x 0.32mm x 0.25µm<br />

(Part No. 19654)<br />

Temp: 220°C<br />

Carrier Gas: Helium at 1.09mL/min<br />

Detector: FID<br />

Sugars<br />

<br />

TMS Sugars<br />

Wax<br />

Carnuba Wax<br />

1118 2625<br />

<br />

<br />

<br />

<br />

1. l-Arabinose<br />

2. d-Xylose<br />

3. β-d-Fructose<br />

4. α-d-Fructose<br />

5. β-d-Glucose<br />

6. d-Galactose<br />

<br />

Column: 6ft x 2mm i.d., Glass<br />

Packing: 3% OV-101 on Chromosorb ® W-HP, 80/100<br />

(Part No. 12019)<br />

Temp:<br />

160°C to 250°C at 10°C/min<br />

Carrier Gas: Nitrogen at 20mL/min<br />

Detector: FID<br />

Aromatics<br />

<br />

<br />

BTEX<br />

<br />

<br />

<br />

<br />

1810<br />

1. Benzene<br />

2. Toluene<br />

3. Ethylbenzene<br />

4. p-Xylene<br />

5. m-Xylene<br />

6. o-Xylene<br />

<br />

<br />

Column: Heliflex ® AT-1ht, 15m x 0.25mm x 0.10μm<br />

(Part No. 16367)<br />

Temp:<br />

225°C (1 min hold) to 380°C at 15°C/min<br />

Carrier Gas: Helium at 0.9mL/min (35cm/sec)<br />

Detector: FID at 385°C<br />

<br />

<br />

<br />

<br />

<br />

Aromatics and MTBE<br />

<br />

<br />

1. MTBE<br />

2. Methanol<br />

3. Benzene<br />

4. Toluene<br />

5. Ethylbenzene<br />

6. p-Xylene<br />

7. m-Xylene<br />

8. o-Xylene<br />

9. Styrene<br />

1939<br />

foods, flavors, & fragrances<br />

<br />

Column: Econo-Cap EC-Wax, 30m x 0.53mm x 1.20µm<br />

(Part No. 19659)<br />

Temp:<br />

40°C (8 min hold) to 100°C at 4°C/min<br />

Carrier Gas: Helium at 2.5mL/min (21.9 cm/sec)<br />

Detector: FID at 275°C<br />

<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

<br />

Econo-Cap EC-Wax, 30m x 0.32mm x 0.25µm<br />

(Part No. 19654)<br />

40°C (8 min hold) to 100°C at 4°C/min<br />

Helium at 1.08mL/min<br />

FID<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

481


gc applications<br />

Aromatics<br />

1<br />

Substituted Benzenes<br />

3<br />

1365<br />

2<br />

Substituted Benzenes<br />

10<br />

1368<br />

2<br />

4<br />

5 6<br />

1. Toluene<br />

2. Ethylbenzene<br />

3. p-Xylene<br />

4. m-Xylene<br />

5. Isopropylbenzene<br />

6. o-Xylene<br />

1<br />

4<br />

3 5<br />

78 9<br />

6<br />

1. Benzene<br />

2. Toluene<br />

3. Ethylbenzene<br />

4. p-Xylene<br />

5. m-Xylene<br />

6. o-Xylene<br />

7. Isopropylbenzene<br />

8. Propylbenzene<br />

9. 1,3,5-Trimethylbenzene<br />

10. 1,2,3-Trimethylbenzene<br />

0 3 6 9 12 15 Min.<br />

Column: Heliflex ® AT-1000, 60m x 0.25mm x 0.20µm<br />

(Part No. 972560)<br />

Temp: 70°C<br />

Carrier Gas: Helium at 0.7mL/min<br />

Detector: FID<br />

0 2 4 6 8 10 12 Min.<br />

Column: Heliflex ® AT-Wax, 30m x 0.53mm x 1.20µm<br />

(Part No. 9951302)<br />

Temp:<br />

40°C to 150°C at 5°C/min<br />

Carrier Gas: Hydrogen at 6mL/min<br />

Detector: FID<br />

Sulfur Gases<br />

6<br />

5<br />

2<br />

3<br />

Sulfur Gases in Air<br />

1. Hydrogen Sulfide<br />

2. Carbonyl Sulfide<br />

3. Sulfur Dioxide<br />

4. Methyl Mercaptan<br />

5. Methyl Sulfide<br />

6. Dimethyl Disulfide<br />

1067<br />

Fuel<br />

<br />

<br />

<br />

<br />

<br />

<br />

Diesel Fuel<br />

1. n-Decane<br />

2. n-Dodecane<br />

3. n-Tetradecane<br />

4. n-Hexadecane<br />

5. n-Octadecane<br />

6. n-Eicosane<br />

7. n-Docosane<br />

8. n-Tetracosane<br />

2623<br />

1<br />

4<br />

<br />

<br />

petroleum & petrochemical<br />

0 1 2 3 4 5 6 7 Min.<br />

Column: 30" x 1/8" o.d., PTFE (Part No. 9781)<br />

Packing: 18" Super Q, 80/100 (Part No. 2735)<br />

Temp:<br />

30°C (1 min hold) to 210°C at 40°C/min<br />

Carrier Gas: Helium at 40mL/min<br />

Detector: FPD<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Jet Fuel A<br />

1. n-Nonane (C9)<br />

2. n-Decane (C10)<br />

3. n-Undecane (C11)<br />

4. n-Dodecane(C12)<br />

5. n-Tridecane (C13)<br />

6. n-Tetradecane (C14)<br />

7. n-Pentadecane (C15)<br />

8. n-Hexadecane (C16)<br />

<br />

<br />

Column: Heliflex ® AT-1ht, 15m x 0.25mm x 0.10μm<br />

(Part No. 16367)<br />

Temp:<br />

75°C (1 min hold) to 340°C at 15°C/min<br />

Carrier Gas: Helium at 1mL/min (33cm/sec)<br />

Detector: FID at 350°C<br />

Kerosene<br />

2627 2629<br />

<br />

1. n-Nonane (C9)<br />

2. n-Decane (C10)<br />

<br />

3. n-Undecane (C11)<br />

<br />

4. n-Dodecane(C12)<br />

5. n-Tridecane (C13)<br />

6. n-Tetradecane (C14)<br />

7. n-Pentadecane (C15)<br />

<br />

8. n-Hexadecane (C16)<br />

<br />

<br />

<br />

<br />

Column: Heliflex ® AT-1ht, 30m x 0.25mm x 0.10μm<br />

(Part No. 16368)<br />

Temp:<br />

75°C (2 min hold) to 325°C at 15°C/min<br />

Carrier Gas: Helium at 1mL/min (28cm/sec)<br />

Detector: FID at 385°C<br />

<br />

Column: Heliflex ® AT-1ht, 30m x 0.25mm x .10µm<br />

(Part No. 16368)<br />

Temp:<br />

75°C (2 min hold) to 325°C at 15°C/min<br />

Carrier Gas: Helium at 1mL/min (28cm/sec)<br />

Detector: FID at 385°C<br />

482<br />

www.discoverysciences.com


gc applications<br />

Fuel<br />

Texas Crude Oil<br />

<br />

<br />

1. n-Decane<br />

10. n-Octadecane<br />

22. n-Nonacosane<br />

<br />

2. n-Undecane<br />

11. Phytane<br />

23. n-Triacontane<br />

3. n-Dodecane<br />

12. n-Nonadecane<br />

24. n-Hentriacontane<br />

<br />

4. n-Tridecane<br />

13. n-Eicosane<br />

25. n-Dotriacontane<br />

<br />

5. n-Tetradecane<br />

14. n-Heneicosane<br />

26. n-Tritriacontane<br />

<br />

6. n-Pentadecane<br />

15. n-Docosane<br />

27. n-Tetratriacontane<br />

<br />

7. n-Hexadecane<br />

16. n-Tricosane<br />

28. n-Pentatriacontane<br />

8. n-Heptadecane<br />

17. n-Tetracosane<br />

29. n-Hexatriacontane<br />

9. Pristane<br />

18. n-Pentacosane<br />

30. n-Heptatriacontane<br />

<br />

19. n-Hexacosane<br />

31. n-Octatriacontane<br />

20. n-Heptacosane<br />

32. n-Nonatriacontane<br />

21. n-Octacosane<br />

33. n-Tetracontane<br />

<br />

<br />

<br />

<br />

<br />

<br />

Column: Heliflex ® AT-1ht, 15m x 0.25mm x 0.10µm<br />

<br />

<br />

(Part No. 16367)<br />

Temp:<br />

70°C (2 min hold) to 380°C at 15°C/min<br />

Carrier Gas: Helium at 1.6mL/min (45cm/sec)<br />

Detector: FID at 390°C<br />

2626<br />

Unleaded Gasoline<br />

234 678 14<br />

9<br />

10<br />

1<br />

5<br />

11<br />

12<br />

13<br />

15<br />

16<br />

18<br />

17<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Min.<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

19<br />

<br />

21<br />

20<br />

22<br />

<br />

<br />

<br />

<br />

<br />

23<br />

1. Isobutane<br />

2. n-Butane<br />

3. Isopentane<br />

4. Pentane<br />

5. 2,3-Dimethylbutane<br />

24<br />

25<br />

1. n-Butane<br />

2. Isobutane<br />

3. n-Pentane<br />

4. 2-Methylpentane<br />

5. 3-Methylpentane<br />

6. n-Hexane<br />

7. Methylcyclopentane<br />

8. 2,4-Dimethylpentane<br />

9. Benzene<br />

Column:<br />

Unleaded Gasoline<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

6. 2-Methylpentane<br />

7. 3-Methylpentane<br />

8. Hexane<br />

9. 2,4-Dimethylpentane<br />

10. Benzene<br />

11. 2-Methylhexane<br />

12. 3-Methylhexane<br />

13. n-Heptane<br />

14. Toluene<br />

15. Ethylbenzene<br />

10. 2-Methylhexane<br />

11. 3-Methylhexane<br />

12. n-Heptane<br />

13. Toluene<br />

14. Ethylbenzene<br />

15. m-Xylene<br />

16. p-Xylene<br />

17. 2-Methyloctane<br />

18. o-Xylene<br />

16. m-Xylene<br />

17. p-Xylene<br />

18. o-Xylene<br />

19. 1-Methyl-3-Ethylbenzene<br />

20. 1,3,5-Trimethylbenzene<br />

21. 1,2,4-Trimethylbenzene<br />

22. 1,2,3-Trimethylbenzene<br />

23. Naphthalene<br />

24. 2-Methylnaphthalene<br />

25. 1-Methylnaphthalene<br />

Heliflex ® AT-Petro, 100m x 0.25mm x 0.50µm<br />

(Part No. 13948)<br />

35°C (15 min hold) to 200°C at 2°C/min<br />

Helium at 0.65mL/min<br />

FID<br />

19. n-Nonane<br />

20. Propylbenzene<br />

21. 1,2,4-Trimethylbenzene<br />

22. n-Decane<br />

23. n-Undecane<br />

24. 2-Methylnaphthalene<br />

25. 1-Methylnaphthalene<br />

26. Dimethylnaphthalenes<br />

Column: Heliflex ® AT-1, 30m x 0.25mm x 1.00µm<br />

(Part No. 13639)<br />

Temp:<br />

35°C (12 min hold) to 200°C at 4°C/min<br />

Carrier Gas: Helium at 0.65mL/min<br />

Split Ratio: 100:1<br />

Detector: FID<br />

1859<br />

2041<br />

petroleum & petrochemical<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

483


gc applications<br />

Gases<br />

C1-C2 Hydrocarbons<br />

1451<br />

1 2 3<br />

4<br />

5<br />

6<br />

C1-C5 Paraffins<br />

1728<br />

1<br />

2<br />

3<br />

1. Air<br />

2. Methane<br />

3. Carbon Dioxide<br />

4. Ethylene<br />

5. Ethane<br />

6. Acetylene<br />

1. Methane (0.1894%)<br />

2. Ethane (0.0965%)<br />

3. Propane (0.0989%)<br />

4. Isobutane (0.1019%)<br />

5. Butane (0.1019%)<br />

6. n-Pentane (0.2002%)<br />

4<br />

5 6<br />

0 2 4 6 8 Min.<br />

Column: 5ft x 1/8" o.d., SS (Custom Part No. C-5000*)<br />

Packing: HayeSep ® T, 80/100 (Part No. 2813)<br />

Temp: 32°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD at 180°C<br />

*Custom column. Must specifiy dimensions, packing and GC.<br />

0 3 6 9 12 Min.<br />

Column: 10ft x 1/8" o.d., SS (Part No. 28301PC)<br />

Packing: HayeSep ® D, 100/120 (Part No. 2830)<br />

Temp:<br />

120°C to 200°C at 20°C/min<br />

Carrier Gas: Helium at 35mL/min<br />

Detector: FID<br />

<br />

<br />

<br />

C1-C2 Hydrocarbons<br />

1. Methane (1%)<br />

2. Acetylene (1%)<br />

3. Ethylene (1%)<br />

4. Ethane (1%)<br />

1727<br />

2<br />

1<br />

3<br />

4 5 6<br />

7 8 9<br />

Hydrocarbons, Sulfur Gases<br />

10 11<br />

1. Air<br />

2. Methane<br />

3. Carbon Dioxide<br />

4. Acetylene<br />

5. Ethylene<br />

6. Ethane<br />

7. Water<br />

8. Hydrogen Sulfide<br />

9. Carbonyl Sulfide<br />

10. Propylene<br />

11. Propane<br />

1772<br />

petroleum & petrochemical<br />

<br />

Column: 10ft x 1/8" o.d., SS (Part No. 28301PC)<br />

Packing: HayeSep ® D, 100/120 (Part No. 2830)<br />

Temp: 80°C<br />

Carrier Gas: Helium at 35mL/min<br />

Detector: FID<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Hydrocarbons<br />

<br />

1. Propane<br />

2. Propylene<br />

3. Isobutane<br />

4. 1-Butene<br />

5. n-Butane<br />

6. Isobutylene<br />

7. cis-2-Butene<br />

8. trans-2-Butene<br />

9. 1,3-Butadiene<br />

10. Isopentane<br />

11. n-Pentane<br />

1862<br />

0 2 4 6 8 Min.<br />

Column: 9ft x 1/8" o.d., SS (Part No. 2833PC)<br />

Packing: HayeSep ® Dip, 100/120 (Part No. 2833)<br />

Temp: 100°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD<br />

1 2 5<br />

6<br />

3<br />

7<br />

4<br />

8<br />

9<br />

10<br />

Hydrocarbons, Sulfur Gases<br />

11<br />

1. Air<br />

2. Methane<br />

3. Carbon Dioxide<br />

4. Ethylene<br />

5. Acetylene<br />

6. Ethane<br />

7. Hydrogen Sulfide<br />

8. Carbonyl Sulfide<br />

9. Propylene<br />

10. Propane<br />

11. Propadiene<br />

1738<br />

<br />

<br />

Column: 2m x 2mm i.d., Glass<br />

Packing: 0.19% Picric Acid on Carbograph 2, 80/100<br />

(Part No. 1736)<br />

Temp: 50°C<br />

Carrier Gas: Nitrogen at 20mL/min<br />

Detector: TCD<br />

0 2 4 6 Min.<br />

Column: 8ft x 1/8" o.d., SS (Part No. 28010PC)<br />

Packing: HayeSep ® Q, 80/100 (Part No. 2801)<br />

Temp: 90°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD at 120°C<br />

484<br />

www.discoverysciences.com


gc applications<br />

Gases<br />

Scott Mix 216<br />

1726<br />

<br />

<br />

Gas Mixture<br />

1452<br />

1<br />

2<br />

3<br />

4<br />

5 6 7<br />

1. Nitrogen (Balance)<br />

2. Carbon Monoxide (1%)<br />

3. Methane (1%)<br />

4. Carbon Dioxide (1%)<br />

5. Acetylene (1%)<br />

6. Ethylene (1%)<br />

7. Ethane (1%)<br />

<br />

<br />

<br />

<br />

<br />

1. Nitrogen<br />

2. Carbon Monoxide<br />

3. Methane<br />

4. Carbon Dioxide<br />

5. Acetylene<br />

6. Ethylene<br />

7. Water<br />

8. Ethane<br />

<br />

0 11 Min.<br />

Column: 20ft x 1/8" o.d., Nickel (Part No. 27082PC)<br />

Packing: HayeSep ® D, 100/120 (Part No. 2830)<br />

Temp:<br />

40°C (2 min hold) to 110°C at 24°C/min<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD at 140°C<br />

<br />

Column: 30ft x 1/8" o.d., SS (Part No. 2836PC)<br />

Packing: Hayesep ® DB, 100/120 (Part No. 2836)<br />

Temp: 120°C<br />

Carrier Gas: Helium at 28mL/min<br />

Detector: TCD<br />

Alcohols<br />

<br />

<br />

<br />

<br />

<br />

Blood Test Mix<br />

1. Acetaldehyde<br />

2. Acetone<br />

3. Methanol<br />

4. Isopropanol<br />

5. Ethanol<br />

6. n-Propanol<br />

Bourbon<br />

1244 4 7<br />

2797<br />

6<br />

1. Acetaldehyde<br />

2. Ethyl Acetate<br />

3. Methanol<br />

4. Ethanol<br />

5. n-Propanol<br />

6. Isobutanol<br />

7. Amyl Alcohol +<br />

2<br />

8<br />

Isoamyl Alcohol<br />

8. Acetic Acid<br />

5<br />

1 3<br />

<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1<br />

3<br />

2<br />

5<br />

4 6<br />

8<br />

7<br />

Heliflex ® AT-Wax, 30m x 0.53mm x 1.20µm<br />

(Part No. 9951302)<br />

40°C (10 min hold) to 150°C at 10°C/min<br />

Hydrogen at 4.3mL/min<br />

FID<br />

10<br />

9<br />

11<br />

12<br />

13<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

14<br />

17<br />

18<br />

15<br />

16<br />

19<br />

C1-C10 Alcohols<br />

0 2 4 6 8 10 12 14 16 18 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1. n-Pentane (solvent)<br />

2. Methanol<br />

3. Ethanol<br />

4. 2-Methyl-2-butanol<br />

5. 2-Butanol<br />

6. 1-Propanol<br />

7. 2-Methyl-1-propanol<br />

8. 2-Propen-1-ol<br />

9. 1-Butanol<br />

10. 4-Methyl-2-pentanol<br />

Heliflex ® AT-Wax, 30m x 0.32mm x 1.00µm<br />

(Part No. 137382)<br />

50°C (1 min hold) to 90°C (0 min hold) at 10°C/min,<br />

then to 225°C (6 min hold) at 20°C/min<br />

Helium at 1.7mL/min<br />

FID<br />

11. 3-Methyl-1-butanol<br />

12. 1-Pentanol<br />

13. 2-Ethyl-1-butanol<br />

14. 1-Hexanol<br />

15. 2-Octanol<br />

16. 1-Heptanol<br />

17. 2-Ethyl-1-hexanol<br />

18. 1-Octanol<br />

19. 1-Decanol<br />

Column: Econo-Cap EC-Wax, 15m x 0.53mm x 1.20µm<br />

(Part No. 19653)<br />

Temp: 50°C (2 min hold), 20°C/min to 220°C<br />

Carrier Gas: Helium at 8.0mL/min<br />

Detector: FID<br />

1002<br />

solvents & chemicals<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

485


gc applications<br />

Alcohols<br />

C1-C7 Alcohols<br />

C1-C6 Alcohols<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1007<br />

1. Methanol<br />

2. 2-Propanol<br />

3. 1-Propanol<br />

4. 2-Butanol<br />

5. 2-Methyl-1-propanol<br />

6. 1-Butanol<br />

7. 3-Methyl-1-butanol<br />

8. 1-Pentanol<br />

9. 2-Ethyl-1-butanol<br />

10. 1-Hexanol<br />

11. Cyclohexanol<br />

12. 3-Methylcyclohexanol<br />

13. 1-Heptanol<br />

1. Methanol<br />

2. Ethanol<br />

3. 2-Propanol<br />

1<br />

2<br />

4 5<br />

3 6<br />

8<br />

7 9<br />

10<br />

1112<br />

13 14<br />

4. 2-Methyl-2-<br />

propanol<br />

5. 1-Propanol<br />

15<br />

16<br />

17 18<br />

6. 2-Butanol<br />

7. 2-Methyl-1-propanol<br />

8. 2-Methyl-2-butanol<br />

9. 1-Butanol<br />

10. 2,2-Dimethyl-1-propanol<br />

11. 3-Methyl-2-butanol<br />

12. 2-Pentanol + 3-Pentanol<br />

13. 3-Methyl-1-butanol<br />

14. 2-Methyl-1-butanol<br />

15. 4-Methyl-2-pentanol<br />

16. 1-Pentanol<br />

17. 1-Hexanol<br />

18. Cyclohexanol<br />

1255<br />

<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1<br />

3<br />

2<br />

Econo-Cap EC-1, 30m x 0.32mm x 0.25µm<br />

(Part No. 19651)<br />

40°C to 120°C at 10°C/min<br />

Helium at 1.09mL/min (26.7cm/sec)<br />

FID<br />

78<br />

5 6<br />

4<br />

C1-C6 Alcohols<br />

9<br />

1. Methanol<br />

2. Ethanol<br />

3. 1-Propanol<br />

4. 2-Methyl-1-propanol<br />

5. 1-Butanol<br />

6. 4-Methyl-2-pentanol<br />

7. 1-Pentanol<br />

8. 2-Ethyl-1-butanol<br />

9. 1-Hexanol<br />

2596<br />

0 1 2 3 4 5 6 7 8 9 10 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1<br />

4<br />

3<br />

2<br />

5<br />

6<br />

Heliflex ® AT-1, 30m x 0.53mm x 5.00µm<br />

(Part No. 16843)<br />

35°C to 100°C at 5°C/min<br />

Helium at 3mL/min<br />

FID<br />

7 8<br />

Aromatic Alcohols<br />

1249<br />

1. α,α-Dimethylbenzyl Alcohol<br />

2. dl-α-Methylbenzyl Alcohol<br />

3. Benzyl Alcohol<br />

4. 2-Phenylethyl Alcohol<br />

5. 3-Phenyl-1-propanol<br />

6. Cinnamyl Alcohol<br />

7. Phenyl-1,2-ethanediol<br />

8. Benzhydrol<br />

solvents & chemicals<br />

0<br />

2 4 6 8 10 12 14 16 18 20 Min. 0 2 4 6 8 10 12 14 Min.<br />

Column: Heliflex ® AT-Wax, 30m x 0.32mm x 1.00μm<br />

(Part No. 137382)<br />

Temp:<br />

40°C (3 min hold) to 150°C at 10°C/min<br />

Carrier Gas: Helium at 1.2mL/min (25cm/sec)<br />

Detector: FID at 275°C<br />

4 5 C1-C6 Alcohols<br />

6 7 8 9<br />

2 3<br />

1<br />

1. Methanol<br />

2. Ethanol<br />

3. 2-Propanol<br />

4. 1-Propanol<br />

5. 2-Methyl-1-propanol<br />

6. 1-Butanol<br />

7. 3-Methyl-1-butanol<br />

8. 1-Pentanol<br />

9. 1-Hexanol<br />

2598<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Amines<br />

1<br />

2 3<br />

4<br />

*<br />

5<br />

*<br />

6<br />

Heliflex ® AT-Wax, 10m x 0.53mm x 1.20µm<br />

(Part No. 9951102)<br />

120°C to 215°C at 10°C/min<br />

Helium at 10mL/min<br />

FID<br />

Aliphatic Amines<br />

7<br />

8<br />

9 10 11<br />

1. Methylamine<br />

2. Dimethylamine<br />

3. Ethylamine<br />

4. Trimethylamine<br />

5. Isopropylamine<br />

6. n-Propylamine<br />

7. t-Butylamine<br />

8. Diethylamine<br />

9. sec-Butylamine<br />

10. Isobutylamine<br />

11. n-Butylamine<br />

* Impurity<br />

1814<br />

0 1 2 3 4 5 6 7 8 9 10 Min.<br />

Column: Heliflex ® AT-5, 30m x 0.32mm x 1.00µm<br />

(Part No. 13659)<br />

Temp:<br />

40°C to 120°C at 10°C/min<br />

Carrier Gas: Helium at 1.2mL/min (25cm/sec)<br />

Detector: FID at 275°C<br />

0 2 4 6 8 10 Min.<br />

Column: 2m x 2mm i.d., Glass<br />

Packing: 4% Carbowax ® 20M + 0.8% KOH on Carbograph 1,<br />

60/80 (Part No. 1735)<br />

Temp:<br />

90°C to 150°C at 4°C/min<br />

Carrier Gas: Nitrogen at 20mL/min<br />

Detector: FID<br />

486<br />

www.discoverysciences.com


gc applications<br />

Amines<br />

Polyamines<br />

2248<br />

2<br />

4<br />

Ethylamines<br />

1095<br />

<br />

<br />

1. Putrecine<br />

2. Cadaverine<br />

1<br />

3<br />

5<br />

1. Ammonia<br />

2. Ethylamine<br />

3. Ethanol<br />

4. Diethylamine<br />

5. Triethylamine<br />

<br />

Column: Heliflex ® AT-CAM, 30m x 0.32mm x 0.25µm<br />

(Part No. 13024)<br />

Temp: 140°C<br />

Carrier Gas: Helium at 30cm/sec<br />

Detector: FID<br />

0 2 4 6 8 10 Min.<br />

Column: 6ft x 4mm i.d., Glass<br />

Packing: 28% AT-223 + 4% KOH on Gas Chrom R, 80/100<br />

(Part No. 49259)<br />

Temp: 130°C<br />

Carrier Gas: Helium at 75mL/min<br />

Detector: TCD<br />

Gases<br />

Ammonia<br />

Sulfur Compounds<br />

2 3<br />

1770<br />

<br />

1800<br />

<br />

1. Air<br />

2. Ammonia (35%)<br />

3. Water (65%)<br />

<br />

1. Hydrogen Sulfide<br />

2. Carbonyl Sulfide<br />

3. Sulfur Dioxide<br />

4. Methyl Mercaptan<br />

1<br />

<br />

0 1 2 3 Min.<br />

Column: 8ft x 1/8" o.d., SS (Part No. 2803PC)<br />

Packing: HayeSep ® P, 60/80 (Part No. 2803)<br />

Temp: 80°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD<br />

1<br />

2 3<br />

Carbon Dioxide and Nitrous Oxide<br />

1. Air<br />

2. Carbon Dioxide<br />

3. Nitrous Oxide<br />

1484<br />

<br />

Column: 2m x 2mm i.d., Glass<br />

Packing: Carbograph 1SC, 40/60 (Part No. 1734)<br />

Temp: 35°C<br />

Carrier Gas: Nitrogen at 20mL/min<br />

Detector: FPD<br />

solvents & chemicals<br />

0 2 Min.<br />

Column: 8ft x 1/8" o.d., SS (Custom Part No. C-5000*)<br />

Packing: Chromosorb ® 101, 80/100 (Part No. 2406)<br />

Temp: 45°C<br />

Carrier Gas: Helium at 35mL/min<br />

Detector: TCD<br />

*Custom column. Must specifiy dimensions, packing and GC.<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

487


gc applications<br />

Gases<br />

Permanent Gases<br />

CTR I - Air, CO, CH4, CO2, O2, N2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

1. Hydrogen<br />

2. Oxygen<br />

3. Nitrogen<br />

4. Methane<br />

5. Carbon Monoxide<br />

2134<br />

1 3<br />

2<br />

4<br />

5<br />

1. Air and Carbon Monoxide<br />

(Inner Column)<br />

2. Methane (Inner Column)<br />

3. Carbon Dioxide (Inner Column)<br />

4. Oxygen (Outer Column)<br />

5. Nitrogen (Outer Column)<br />

6. Methane (Outer Column)<br />

7. Carbon Monoxide (Outer Column)<br />

6 7<br />

1059<br />

0 1 2 3 4 5 Min.<br />

Column: 6ft x 1/8" o.d., SS (Part No. 5773PC)<br />

Packing: Molecular Sieve 13X, 80/100 (Part No. 5638)<br />

Temp: 35°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

Column: CTR I (Part No. 8700)<br />

Outer Column: 6ft x 1/4" Packed with Activated Molecular Sieve<br />

Inner Column: 6ft x 1/8" Packed with Porous Polymer Mixture<br />

Temp:<br />

Ambient<br />

Carrier Gas: Helium at 65mL/min<br />

Detector: TCD<br />

1 2 3<br />

N2, CO2, N2O, HS CO2, COS, SO2<br />

1771<br />

<br />

1478<br />

5<br />

1. Nitrogen (Balance)<br />

2. Carbon Dioxide (2%)<br />

3. Nitrous Oxide (3%)<br />

4. Water (0.5%)<br />

5. Hydrogen Sulfide (3%)<br />

<br />

<br />

1. Air, Carbon Monoxide<br />

2. Carbon Dioxide<br />

3. Water<br />

4. Carbonyl Sulfide<br />

5. Sulfur Dioxide<br />

4<br />

<br />

0 7 Min.<br />

<br />

solvents & chemicals<br />

Column: 10ft x 1/8" o.d., SS (Part No. 28301PC)<br />

Packing: HayeSep ® D, 100/120 (Part No. 2830)<br />

Temp: 80°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD<br />

1<br />

2<br />

3<br />

4<br />

CH4, CO2, N2O<br />

1. Air<br />

2. Methane<br />

3. Carbon Dioxide<br />

4. Nitrous Oxide<br />

1712<br />

Column: 6ft x 2mm i.d., Glass<br />

Packing: Porapak ® Q, 80/100 (Part No. 2701)<br />

Temp: 75°C<br />

Carrier Gas: Helium at 20mL/min<br />

Detector: TCD<br />

1<br />

2<br />

Hydrogen/Air<br />

3<br />

1. Hydrogen<br />

2. Nitrogen<br />

3. Oxygen<br />

4. Argon<br />

2460<br />

4<br />

0 1 2 Min.<br />

0 1<br />

2<br />

3<br />

4 5 6 Min.<br />

Column: 6ft x 1/8" o.d., SS (Part No. 5682PC)<br />

Packing: Carbosphere, 80/100 (Part No. 5682)<br />

Temp: 200°C<br />

Carrier Gas: Helium at 20mL/min<br />

Detector: TCD<br />

Column: 25ft x 1/8" o.d., SS (Custom Part No. C-5000*)<br />

Packing: HayeSep ® D, 100/120 (Part No. 2830)<br />

Temp: 25°C<br />

Carrier Gas: Helium at 24mL/min<br />

Detector: TCD<br />

*Custom column. Must specify dimensions, packing, and GC.<br />

488<br />

www.discoverysciences.com


gc applications<br />

Gases<br />

1<br />

5<br />

MAPP Gas<br />

Nitric Oxide<br />

2021 1<br />

2014<br />

2 3<br />

4<br />

6 7 8<br />

1. Air<br />

2. Methane<br />

3. Carbon Dioxide<br />

4. Ethane<br />

5. Propylene<br />

6. Propane<br />

7. Propadiene<br />

8. Methyl Acetylene<br />

2<br />

3<br />

1. Nitrogen (Balance)<br />

2. Argon<br />

3. Nitric Oxide (0.58%)<br />

0 2 4 6 8 Min.<br />

Column: 10ft x 1/8" o.d., SS (Custom Part No. C-5000*)<br />

Packing: HayeSep ® R, 100/120 (Part No. 2808)<br />

Temp: 80°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD<br />

*Custom column. Must specifiy dimensions, packing and GC.<br />

0 2 4 6 8 Min.<br />

Column: 30ft x 1/8" o.d., SS (Part No. 2836PC)<br />

Packing: HayeSep ® DB, 100/120 (Part No. 2836)<br />

Temp: 22°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD at 140°C<br />

1<br />

Permanent Gases<br />

1450<br />

2<br />

1<br />

4<br />

Reactive Gas Mixture<br />

1447<br />

3<br />

2<br />

4<br />

5<br />

1. Nitrogen<br />

2. Oxygen<br />

3. Carbon Monoxide<br />

4. Methane<br />

5. Carbon Dioxide<br />

3<br />

5<br />

6<br />

7<br />

8<br />

1. Air<br />

2. Methane<br />

3. Carbon Dioxide<br />

4. Nitrous Oxide<br />

5. Ammonia<br />

6. Ethane<br />

7. Hydrogen Sulfide<br />

8. Carbonyl Sulfide<br />

0 3 6 9 12 15 18 Min.<br />

0 5 10 15 20 Min.<br />

Column: 20ft x 1/8" o.d., Ni (Part No. 27082PC)<br />

Packing: HayeSep ® D, 100/120 (Part No. 2830)<br />

Temp: 25°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD<br />

1<br />

2<br />

Column: 8ft x 1/8" o.d., SS (Part No. 28010PC)<br />

Packing: HayeSep ® Q, 80/100 (Part No. 2801)<br />

Temp: 50°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD<br />

Room Air Scott Mix 234<br />

<br />

1706<br />

1. Nitrogen (78%)<br />

2. Oxygen (21%)<br />

3. Argon (0.94%)<br />

1. Helium (Balance)<br />

2. Hydrogen (4%)<br />

3. Oxygen (4%)<br />

4. Methane (4%)<br />

2020<br />

solvents & chemicals<br />

3<br />

<br />

<br />

0 2 4 Min.<br />

<br />

<br />

Column: 30ft x 1/8" o.d., SS (Part No. 2836PC)<br />

Packing: Hayesep ® DB, 100/120 (Part No. 2836)<br />

Temp:<br />

-66°C<br />

Carrier Gas: Helium at 30mL/min<br />

Detector: TCD<br />

Column: 30ft x 1/8" o.d., SS (Part No. 2836PC)<br />

Packing: HayeSep ® DB, 100/120 (Part No. 2836)<br />

Temp: 22°C<br />

Carrier Gas: Nitrogen at 30mL/min<br />

Detector: TCD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

489


gc applications<br />

Glycols/Diols<br />

Diols<br />

1<br />

EG and Diols<br />

1 2<br />

1225<br />

2<br />

1275<br />

3<br />

4 5 6 7<br />

1. 1,2-Butanediol<br />

2. 1,2-Propanediol<br />

3. Ethylene Glycol<br />

4. 1,3-Butanediol<br />

5. 1,3-Propanediol<br />

6. 1,4-Butanediol<br />

7. 1,5-Pentanediol<br />

3<br />

4<br />

1. Ethylene Glycol<br />

2. 1,2-Propanediol<br />

3. 1,3 Butanediol<br />

4. 1,4-Butanediol<br />

0 2 4 6 8 10 Min.<br />

Column: Heliflex ® AT-Wax, 25m x 0.25mm x 0.20µm<br />

(Part No. 9925252)<br />

Temp: 150°C<br />

Carrier Gas: Hydrogen at 0.9mL/min<br />

Detector: FID<br />

0 1 2 3 4 5 6 7 Min.<br />

Column: Heliflex ® AT-Wax, 10m x 0.53mm x 1.20µm<br />

(Part No. 9951102)<br />

Temp: 110°C<br />

Carrier Gas: Helium at 22mL/min<br />

Detector: FID<br />

1<br />

Ethylene Glycol/2-Chloroethanol<br />

1839<br />

1<br />

2<br />

3<br />

5<br />

Glycol Amines<br />

1266<br />

2 3<br />

1. Water<br />

2. 2-Chloroethanol<br />

3. Ethylene Glycol<br />

4<br />

1. Ethanolamine<br />

2. Ethylene Glycol<br />

3. Diethylene Glycol<br />

4. Diethanolamine<br />

5. Triethylene Glycol<br />

solvents & chemicals<br />

0 1 2 3 4 Min.<br />

Column: Econo-Cap EC-1000, 15m x 0.53mm x 1.20µm<br />

(Part No. 19684)<br />

Temp: 120°C<br />

Carrier Gas: Helium at 15mL/min<br />

Detector: FID<br />

1<br />

2<br />

3 4<br />

5<br />

6<br />

Glycol-Diol Mix<br />

7<br />

8<br />

1. Ethylene Glycol<br />

2. 1,2-Propanediol<br />

3. 2,3-Butanediol<br />

4. 1,3-Propanediol<br />

5. 1,3-Butanediol<br />

6. 1,4-Butanediol<br />

7. Diethylene Glycol<br />

8. Glycerol<br />

1087<br />

0 2.5 5 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Solvents<br />

1 2 3 4 5 6<br />

Heliflex ® AT-Wax, 10m x 0.53mm x 1.20µm<br />

(Part No. 9951102)<br />

130°C to 180°C at 10°C/min<br />

Helium at 21mL/min<br />

FID<br />

7<br />

8<br />

9 10<br />

11<br />

Aromatics<br />

12<br />

1. Benzene<br />

2. Toluene<br />

3. Ethylbenzene<br />

4. p-Xylene<br />

5. m-Xylene<br />

6. o-Xylene<br />

7. Chlorobenzene<br />

8. 1,4-Dichlorobenzene<br />

9. 1,2-Dichlorobenzene<br />

10. 1,2,4-Trichlorobenzene<br />

11. 1,2,3-Trichlorobenzene<br />

12. Napthalene<br />

2586<br />

0 1 2 3 4 Min.<br />

0<br />

2 4 6 8 10 1214 16 18 20 22 24 min.<br />

Column: 4ft x 3mm i.d., Glass<br />

Packing: Chromosorb ® 101, 100/120 (Part No. 2407)<br />

Temp: 210°C<br />

Carrier Gas: Helium at 50mL/min<br />

Detector: FID<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-Wax, 30m x 0.32mm x 1.00µm<br />

(Part No. 137382)<br />

60°C (4 min hold) to 200°C at 10°C/min<br />

Helium at 1.3mL/min (24cm/sec)<br />

FID<br />

490<br />

www.discoverysciences.com


gc applications<br />

Solvents<br />

Volatile Organics<br />

4<br />

Glycol Ethers<br />

1878<br />

1337<br />

1<br />

2<br />

3 4 5<br />

6<br />

7 8<br />

9 10<br />

1. Methylene Chloride<br />

2. Chloroform<br />

3. Carbon Tetrachloride<br />

4. 1,2-Dichloropropane<br />

5. Benzene<br />

6. Toluene<br />

7. Chlorobenzene<br />

8. Ethylbenzene<br />

9. 1,3-Dichlorobenzene<br />

10. 1,2-Dichlorobenzene<br />

1<br />

2<br />

3<br />

5<br />

1. Cellosolve Acetate<br />

2. Methyl Carbitol ®<br />

3. Carbitol<br />

4. n-Decane<br />

5. Butyl Carbitol<br />

0 4 8 12 16 20 24 28 32 36 40 Min.<br />

Column: 2m x 2mm i.d., Glass<br />

Packing: 1% AT-1000 on Carbograph 1, 60/80 (Part No. 1733)<br />

Temp:<br />

45°C (3 min hold) to 230°C at 8°C/min<br />

Carrier Gas: Nitrogen at 20mL/min<br />

Detector: FID<br />

0 1 2 3 4 5 Min.<br />

Column: Heliflex ® AT-1, 10m x 0.53mm x 1.20µm<br />

(Part No. 935110)<br />

Temp:<br />

60°C to 160°C at 5°C/min<br />

Carrier Gas: Helium at 20mL/min<br />

Detector: FID<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Aromatics<br />

<br />

1. Benzene<br />

2. Toluene<br />

3. Chlorobenzene<br />

4. Ethylbenzene<br />

5. m-Xylene<br />

6. p-Xylene<br />

7. o-Xylene<br />

8. 1,4-Dichlorobenzene<br />

9. 1,2-Dichlorobenzene<br />

10. 1,2,4-Trichlorobenzene<br />

11. Napthalene<br />

12. 1,2,3-Trichlorobenzene<br />

2587<br />

10<br />

3<br />

4<br />

6<br />

2 78<br />

5<br />

1<br />

9<br />

Impurities in Methyl Ethyl Ketone<br />

1. Methanol<br />

2. Ethanol<br />

3. 2-Propanol<br />

4. 2-Methyl-2-propanol<br />

5. n-Propanol<br />

6. 2-Butanol<br />

7. Acetone<br />

8. 1-Octene<br />

9. Ethyl Acetate<br />

10. Methyl Ethyl Ketone<br />

1221<br />

<br />

<br />

0 5 10 15 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1<br />

Heliflex ® AT-1, 30m x 0.32mm x 1.00µm<br />

(Part No. 13641)<br />

60°C (4 min hold) to 200°C at 10°C/min<br />

Helium at 1.3mL/min<br />

FID<br />

Ethylene Glycol, Ethylene Oxide and<br />

2-Chloroethanol in DMF<br />

2 3<br />

4<br />

5<br />

6<br />

1812<br />

1. Ethylene Oxide<br />

2. Methanol<br />

3. N,N-Dimethylformamide<br />

(solvent)<br />

4. 2-Chloroethanol<br />

5. Impurity in Solvent<br />

6. Ethylene Glycol<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Heliflex ® AT-210, 30m x 0.53mm x 1.20µm<br />

(Part No. 985130)<br />

80°C (1 min hold) to 170°C at 7°C/minute<br />

Helium at 3.7mL/min<br />

FID<br />

Halogenated Aromatics<br />

1. 2-Bromobutane<br />

2. 1-Bromobutane<br />

3. Chlorobenzene<br />

4. 1,4-Dichlorobutane<br />

5. 1-Bromohexane<br />

6. Bromocyclohexane<br />

7. o-Chlorotoluene<br />

8. Benzyl Chloride<br />

1345<br />

solvents & chemicals<br />

0 2 4 6 8 12 14 16 Min.<br />

0 1 2 3 Min.<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Econo-Cap EC-Wax, 30m x 0.25mm x 0.25µm<br />

(Part No. 19655)<br />

40°C (2 min hold) to 180°C at 10°C/min<br />

Helium at 0.65mL/min<br />

FID<br />

Column: Heliflex ® AT-1, 10m x 0.53mm x 1.20µm<br />

(Part No. 935110)<br />

Temp: 60°C<br />

Carrier Gas: Helium at 10mL/min<br />

Detector: FID<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

491


gc applications<br />

Solvents<br />

2<br />

3<br />

5<br />

1 10<br />

7 14<br />

12<br />

6 8 13<br />

9<br />

4 11<br />

19<br />

18<br />

15 16<br />

17<br />

0 3 6 9 12 15 Min.<br />

23<br />

20<br />

27<br />

26<br />

21<br />

22<br />

25<br />

24<br />

28<br />

29<br />

30<br />

31<br />

Industrial Solvent Mix<br />

1. Pentane<br />

2. 2,2,4-Trimethylpentane<br />

3. Cyclohexane<br />

4. Methyl Formate<br />

5. Acetone<br />

6. Tetrahydrofuran<br />

7. Ethyl Acetate<br />

8. 2-Butanone<br />

9. 2-Propanol<br />

10. Benzene<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

11. Trichloroethene<br />

12. 4-Methyl-2-pentanone<br />

13. 2-Butanol<br />

14. Toluene<br />

15. Butyl Acetate<br />

16. 2-Methyl-1-propanol<br />

17. 2-Nitropropane<br />

18. Ethylbenzene<br />

19. 1,4-Xylene<br />

20. 1,3-Xylene<br />

21. 1-Butanol<br />

22. Nitromethane<br />

23. 1,2-Xylene<br />

24. 3-Methyl-1-butanol<br />

25. 2-Ethoxyethanol<br />

26. 1-Pentanol<br />

27. Cyclohexanol<br />

28. 2-Ethoxyethyl Acetate<br />

29. 1-Hexanol<br />

30. 2-Butoxyethanol<br />

31. 1-Heptanol<br />

Econo-Cap EC-Wax, 30m x 0.32mm x 0.25µm<br />

(Part No. 19654)<br />

50°C (5 min hold) to 150°C at 10°C/min<br />

Helium at 1.08mL/min<br />

FID<br />

1015<br />

solvents & chemicals<br />

1. Benzene<br />

2. Trifluoromethylbenzene<br />

3. Toluene<br />

1<br />

2<br />

3<br />

11 12<br />

14<br />

10 13<br />

15<br />

16<br />

17<br />

18<br />

56<br />

7 8 19<br />

4 9<br />

21<br />

25<br />

20 22 27<br />

23<br />

24 26<br />

28 30<br />

29<br />

0 2 4 6 8 10 12 14 16 18 20 22 Min.<br />

1<br />

2 3 4<br />

5<br />

7<br />

6<br />

13 14<br />

11 12 15<br />

8 9 10<br />

16<br />

0 4 8 12 16 20 Min.<br />

4. Chlorobenzene<br />

5. Ethylbenzene<br />

6. 1,3-Xylene<br />

1. Carbon Disulfide<br />

2. Acetone<br />

3. Carbon Tetrachloride<br />

4. 1,1,1-Trichloroethane<br />

5. Methyl Ethyl Ketone<br />

6. Methylene Chloride<br />

7. Benzene<br />

8. Trichloroethylene<br />

Substituted Aromatics<br />

7. 1,2-Xylene<br />

8. Isopropylbenzene<br />

9. Bromobenzene<br />

10. 1-Chloro-2-methylbenzene<br />

11. 1-Chloro-4-methylbenzene<br />

12. 1,3,5-Trimethylbenzene<br />

13. 2-Methyl-2-phenylpropane<br />

14. 1,2,4-Trimethylbenzene<br />

15. 1,3-Dichlorobenzene<br />

16. 1-Isopropyl-4-methylbenzene<br />

17. α-Chlorotoluene<br />

18. 1,2-Dichlorobenzene<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

NIOSH Solvents<br />

9. Chloroform<br />

10. Tetrachloroethylene<br />

11. Toluene<br />

12. p-Dioxane + Ethylene dichloride<br />

13. p-Xylene<br />

14. m-Xylene<br />

15. o-Xylene<br />

16. 1,1,2-Trichloroethane<br />

19. 1-Bromo-4-methylbenzene<br />

20. 4-Chlorostyrene<br />

21. 1-Bromo-4-chlorobenzene<br />

22. 1,2,4,5-Tetramethylbenzene<br />

23. 2,4-Dichlorotoluene<br />

24. 1-Iodo-4-methylbenzene<br />

25. Tetrahydronaphthalene<br />

26. 1,2,4-Trichlorobenzene<br />

27. Naphthalene<br />

28. Hexachlorobutadiene<br />

29. 1,2,4,5-Tetrachlorobenzene<br />

30. 1-Chloronaphthalene<br />

Heliflex ® AT-1301, 30m x 0.25mm x 0.25µm<br />

(Part No. 13959)<br />

50°C (3 min hold) to 170°C at 7°C/min<br />

Helium at 0.65mL/min<br />

FID<br />

Column: 20ft x 1/8" o.d., SS (Part No. C-5000*)<br />

Packing: 10% AT-1000 on Chromosorb ® W-AW, 80/100<br />

(Part No. 12001)<br />

Temp:<br />

60°C (2 min hold) to 160°C at 5°C/minute<br />

Carrier Gas: Nitrogen at 30mL/min<br />

Detector: FID<br />

*Custom column. Must specifiy dimensions, packing and GC.<br />

1838<br />

1177<br />

492<br />

www.discoverysciences.com


gc applications<br />

Test Mixes<br />

<br />

<br />

<br />

<br />

<br />

AT-1ms Test Chromatogram<br />

<br />

<br />

<br />

1. 2-Ethylhexanoic Acid<br />

2. 4-Chlorophenol<br />

3. 1,7-Heptanediol<br />

4. n-Tridecane<br />

5. 1-Undecanol<br />

6. n-Tetradecane<br />

7. Dicyclohexylamine<br />

8. Acenaphthylene<br />

9. n-Pentadecane<br />

<br />

2578<br />

0 5 10 15 20 25 30 Min.<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

Grob Mix<br />

10<br />

11<br />

12<br />

1045<br />

1. n-Decane<br />

2. n-Undecane<br />

3. Nonanal<br />

4. 2,3-Butanediol<br />

5. 1-Octanol<br />

6. Methyl Decanoate<br />

7. Dicyclohexylamine<br />

8. Methyl Undecanoate<br />

9. Methyl Dodecanoate<br />

10. 2,6-Dimethylaniline<br />

11. 2,6-Dimethylphenol<br />

12. 2-Ethylhexanoic Acid<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-1ms, 30m x 0.25mm x 0.25µm<br />

(Part No. 15897)<br />

135°C (20 min hold) to 320°C at 20°C/min<br />

Helium at 0.65mL/min (23.1cm/sec)<br />

FID<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Econo-Cap EC-Wax, 30m x 0.25mm x 0.25µm<br />

(Part No. 19655)<br />

40°C to 220°C at 6°C/min<br />

Helium at 0.61mL/min<br />

FID<br />

Pyrolysis<br />

<br />

Pyrolysis - ABS Plastic<br />

1. 1,3-Butadiene<br />

2. Acrylonitrile<br />

3. Benzene<br />

4. Toluene<br />

5. Vinyl Cyclohexene<br />

6. Styrene<br />

7. α-Methylstyrene<br />

8. Benzenepropanenitrile<br />

9. 1-Benzyl Pyrrole<br />

2417<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Pyrolysis - Isoprene Rubber<br />

Heliflex ® AT-1, 30m x 0.25mm x 0.25µm<br />

(Part No. 13638)<br />

50°C (2 min hold) to 300°C at 10°C/min<br />

Helium at 0.8mL/min<br />

MSD<br />

1. Butene<br />

2. 1,3-Pentadiene<br />

3. Toluene<br />

4. p-Xylene<br />

5. Styrene<br />

6. 1-Ethyl-4-methylbenzene<br />

7. Limonene<br />

8. 2-Methylnaphthalene<br />

2415<br />

solvents & chemicals<br />

<br />

<br />

<br />

<br />

<br />

Column:<br />

Temp:<br />

Carrier Gas:<br />

Detector:<br />

Heliflex ® AT-1, 30m x 0.25mm x 0.25µm<br />

(Part No. 13638)<br />

50°C (2 min hold) to 300°C at 10°C/min<br />

Helium at 0.8mL/min<br />

MSD<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

493


spe applications<br />

Analgesics<br />

SPE Extraction of Salicylic and Acetylsalicylic Acids from Synthetic Urine<br />

10642<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 100mg:<br />

Sample Treatment – Spike 2mL synthetic urine with 100ppm salicylic acid and 100ppm<br />

acetylsalicylic acid.<br />

Conditioning – Rinse device with 3mL methanol followed by 3mL DI water.<br />

Sample Application – Apply 2mL spike urine.<br />

Wash – Wash with 2mL 50mM phosphate buffer monobasic, pH 2.<br />

Elution – Elute with 2mL methanol:water (50:50).<br />

1<br />

2<br />

1. Salicylic Acid<br />

2. Acetylsalicylic Acid<br />

Column: Alltima HP C18 HiLoad, 5µm, 250 x 4.6mm<br />

(Part No. 87698)<br />

Mobile Phase: 5mM Sodium Acetate, pH5.2:Methanol (80:20)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

0 2 4 6 8 10 12 14 16<br />

18 Min.<br />

pharmaceuticals<br />

Sedatives<br />

Procedure using <strong>Grace</strong>Pure C18-Aq, 500mg:<br />

Sample Treatment – Spike 500µL plasma with 10µL of a 0.1mg/mL standard solution.<br />

Combine with 100µL of 0.1M sodium carbonate buffer. Vortex and centrifuge for<br />

10 minutes.<br />

Conditioning – Rinse device 2mL water.<br />

Sample Application – Apply entire sample.<br />

Wash – Wash with 2mL water and then 50µL methanol.<br />

Elution – Elute with 600µL methanol.<br />

Column: Alltima HP C18, 5μm, 250 x 4.6mm (Part No. 87680)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 30<br />

%B: 30 80<br />

Flow Rate: 1mL/min<br />

Detector: UV at 254nm<br />

Benzodiazepines from Human Plasma<br />

1<br />

2 3<br />

1 2<br />

3<br />

0 2 4 6 8 10 12 14 16 18 20 Min.<br />

4<br />

4<br />

1. Oxazepam<br />

2. Clonazepam<br />

3. Temazepam<br />

4. Diazepam<br />

Before SPE<br />

Clean-up<br />

After SPE<br />

Clean-up<br />

10606<br />

10608<br />

494<br />

www.discoverysciences.com


spe applications<br />

Diuretics<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 1000mg:<br />

Sample Treatment – Spike synthetic urine with 8 diuretics to a concentration of<br />

1.25µg/mL each.<br />

Conditioning – Rinse device 5mL methanol, followed by 5mL water.<br />

Sample Application – Apply 15mL spiked urine sample at 1mL/min.<br />

Wash – Wash with 5mL water.<br />

Elution – Elute with 2mL methanol. Evaporate solvent and reconstitute in 250µL<br />

HPLC mobile phase.<br />

Diuretics from Urine<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

10289<br />

10290<br />

1. Acetazolamide<br />

2. Hydrochlorothiazide<br />

3. Hydroflumethiazide<br />

4. Clopamide<br />

5. Trichloromethiazide<br />

6. Indapamide<br />

7. Bendroflumethiazide<br />

8. Spironolactone<br />

Column: Alltima C18, 3μm, 100 x 4.6mm (Part No. 81382)<br />

Mobile Phase: A: 25mM Ammonium Acetate, 0.1%Trifluoroacetic Acid<br />

B: Acetonitrile, 0.1%Trifluoroacetic Acid<br />

Gradient: Time: 0 10<br />

%B: 20 90<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

After SPE<br />

Concentration<br />

Before SPE<br />

Concentration<br />

0 1 2 3 4 5 6 7 8 9 10 Min.<br />

St. John’s Wort<br />

Procedure Using <strong>Grace</strong>Pure C18-Max, 1000mg:<br />

Sample Treatment – Pulverize 300mg St. John’s Wort powder into five, 3mL aliquots<br />

of methanol:water (80:20). Combine and filter extracts to produce 15mL filtrate. Dilute<br />

to 30mL with water.<br />

Conditioning – Rinse device with 5mL methanol followed by 5mL deionized water.<br />

Sample Application – Apply 2mL filtrate to the top of the SPE device and draw through<br />

the C18 packed bed.<br />

Wash* – Wash device with 3mL of deionized water.<br />

Elution – Elute with 2mL methanol.<br />

*Repeat load and wash steps consecutively until filtrate is consumed.<br />

Column: Alltima C18, 3µm 53 x 7mm Rocket (Part No. 50605)<br />

Mobile Phase: Methanol:0.2% Phosphoric Acid (95:5)<br />

Flow Rate: 4.0mL/min<br />

Detector: VIS at 585nm<br />

Hypericins from St. John’s Wort<br />

1<br />

0 1<br />

2<br />

2<br />

9107<br />

1. Pseudohypericin<br />

2. Hypericin<br />

3 Min.<br />

nutraceuticals<br />

Chamomile<br />

Antioxidants from Chamomile<br />

9133<br />

Procedure Using <strong>Grace</strong>Pure C18-Max, 1000mg:<br />

Sample Treatment – Pulverize 1g commercial chamomile tea grounds into<br />

6mL dioxane:methanol (50:50). Filter extract and dilute to 20mL with water.<br />

Conditioning – Rinse device with 5mL methanol followed by 5mL water.<br />

Sample Application* – Apply 1mL filtrate.<br />

Wash* – Wash with 1mL water.<br />

Elution – Elute first with 2mL methanol:water (50:50). Elute second, fraction<br />

and use for this analysis, with 2mL methanol.<br />

*Before elution step, repeat load and wash steps until filtrate is consumed.<br />

1<br />

1. Apigenin-7-Glucoside<br />

Column: Alltima C18, 3µm 53 x 7mm Rocket (Part No. 50605)<br />

Mobile Phase: Acetonitrile:20mM K2HPO4, pH7.3 (65:35)<br />

Flow Rate: 3mL/min<br />

Detector: UV 340nm<br />

Inj. Vol.: 5µL<br />

0 1<br />

2 3 Min.<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

495


spe applications<br />

Echinacea<br />

Phenolic Acids from Echinacea<br />

9110<br />

Procedure Using <strong>Grace</strong>Pure C18-Max, 1000mg:<br />

Sample Treatment – Pulverize 300mg echinacea powder into five, 3mL aliquots of<br />

methanol. Combine and filter extracts to produce 15mL filtrate. Dilute to 30mL with<br />

water.<br />

Conditioning – Rinse device with 5mL methanol followed by 5mL deionized water.<br />

Sample Application – Apply 2mL filtrate to the top of the SPE device and draw through<br />

the C18 packed bed.<br />

Wash* – Wash device with 2mL of deionized water.<br />

Elution – Elute with 5mL of methanol:water (50:50).<br />

*Repeat load and wash steps consecutively until filtrate is consumed.<br />

1<br />

3<br />

1. Echinicoside<br />

2. Chlorogenic Acid<br />

3. Caffeic Acid<br />

Column: Alltima C18, 3µm 53 x 7mm Rocket (Part No. 50605)<br />

Mobile Phase: Acetonitrile:10mM K2HPO4, pH2.6 (20:80)<br />

Flow Rate: 3.5mL/min<br />

Detector: UV at 330nm<br />

0 1<br />

2<br />

2 Min.<br />

Kava Kava<br />

Sedatives from Kava Kava<br />

9125<br />

nutraceuticals<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 1000mg:<br />

Sample Treatment – Pulverize 300mg commercial kava kava root powder into four, 2mL<br />

aliquots of methanol:water (80:20). Combine and filter extracts to produce 8mL filtrate.<br />

Dilute to 10mL with water.<br />

Conditioning – Rinse device with 5mL methanol followed by 5mL water.<br />

Sample Application* – Apply 2mL filtrate.<br />

Wash* – Wash with 2mL water.<br />

Elution – Elute with 3mL methanol.<br />

*Before elution step, repeat load and wash steps until filtrate is consumed.<br />

Column: Alltima C18, 3µm, 53 x 7mm Rocket (Part No. 50605)<br />

Mobile Phase: Acetonitrile:Isopropyl Alcohol:0.2% Acetic Acid (17:23:60)<br />

Flow Rate: 3.5mL/min<br />

Detector: UV 220nm<br />

Inj. Vol.: 5µL<br />

0 1<br />

1<br />

3<br />

4<br />

2<br />

2<br />

3<br />

5<br />

1. Methysticin<br />

2. Yangonin<br />

3. Kavain<br />

4. Dihydrokavain<br />

5. Dihydromethysticin<br />

4<br />

5<br />

Dong Quai<br />

Vasodilators from Dong Quai<br />

9132<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 1000mg:<br />

Sample Treatment – Pulverize 300mg commercial kava kava root powder into four, 2mL<br />

aliquots of methanol:water (80:20). Combine and filter extracts to produce 8mL filtrate.<br />

Dilute to 10mL with water.<br />

Conditioning – Rinse device with 5mL methanol followed by 5mL water.<br />

Sample Application* – Apply 2mL filtrate.<br />

Wash* – Wash with 2mL water.<br />

Elution – Elute with 3mL methanol.<br />

*Before elution step, repeat load and wash steps until filtrate is consumed.<br />

1<br />

1. Z-ligustilide<br />

Column: Alltima C18, 3µm 53 x 7mm Rocket (Part No. 50605)<br />

Mobile Phase: Methanol:0.2% Acetic Acid (65:35)<br />

Flow Rate: 4.5mL/min<br />

Detector: UV 270nm<br />

Inj. Vol.: 5µL<br />

0 1<br />

2 3 4 5 Min.<br />

496<br />

www.discoverysciences.com


spe applications<br />

Additives<br />

Procedure using <strong>Grace</strong>Pure Anion-X, 500mg:<br />

Sample Treatment – Use 8mL fruit punch and adjust pH to 10 using potassium<br />

hydroxide.<br />

Conditioning – Rinse device 10mL water.<br />

Sample Application – Apply 8mL pH adjusted fruit punch sample.<br />

Wash – Wash with 20mL water.<br />

Elution – Elute with 1mL 1.0N hydrochloric Acid followed by 1mL methanol.<br />

Preservatives from Fruit Punch<br />

1<br />

1. Sorbic Acid<br />

2. Benzoic Acid<br />

2576<br />

Column: Heliflex ® AT AquaWax-DA, 30m x 0.25mm x 0.25μm<br />

Capillary GC Column (Part No. 14537)<br />

Temp:<br />

200°C (5 min hold) to 230°C (4 min hold) at 5°C/min<br />

Carrier Gas: Helium at 0.75mL/min (25cm/sec)<br />

Detector: FID at 250°C<br />

0<br />

2 4 6 8 10 12 14 Min.<br />

2<br />

Carbohydrates<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 500mg:<br />

Sample Treatment – Add 0.167mg/mL each of carbendazim, thiabendazolem,<br />

triadimenol, triadimefon, flusilazole, diniconazole into<br />

1mL water. Combine with 1mL Beaujolais red wine.<br />

Conditioning – Rinse device with 3mL methanol followed by 3mL water.<br />

Sample Application – Apply 2mL red wine mixture.<br />

Wash – No wash.<br />

Elution – Elute with 3mL methanol.<br />

Column: Alltima HP C18 Amide, 5μm, 250 x 4.6mm<br />

(Part No. 87734)<br />

Mobile Phase: A: Water B: Acetonitrile<br />

Gradient: Time: 0 15 50 65<br />

%B: 15 45 45 15<br />

Flow Rate: 1mL/min<br />

Detector: UV at 254nm<br />

Fungicides from Red Wine<br />

1<br />

2<br />

3<br />

Before SPE<br />

Clean-up<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 Min.<br />

6<br />

1. Carbendazim<br />

2. Thiabendazole<br />

3. Triadimenol<br />

4. Triadimefon<br />

5. Flusilazole<br />

6. Diniconazole<br />

10637<br />

10638<br />

4 5<br />

After SPE<br />

Clean-up<br />

food & beverage<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

497


spe applications<br />

Proteins & Peptides/Reversed Phase<br />

Prevail SPE Protein Desalting, Cytochrome C and Ribonuclease A Mix in 10mM Sodium Chloride<br />

Procedure using Prevail C18, 500mg:<br />

Sample Treatment – Cytochrome-C 1mg/mL, Ribonuclease-a 1mg/mL, Blank = water,<br />

Salt = 10mM NaCl.<br />

Conditioning – 1 tube volume of methanol (do not dry). 2 tube volumes of 0.025%<br />

ammonium hydroxide. Dry tube via vacuum.<br />

Sample Application – Pipette 1mL of sample (either proteins in water blank or proteins<br />

in salt solution) onto top of sorbent bed in SPE tube. Run vacuum @ approximately<br />

-10 kPa, loading sample in a tight band at top of sorbent column, continue to apply<br />

vacuum (@ -10 kPa) until tube is dry. Larger (2mL +) volumes can be de-salted and<br />

concentrated. Liquid collected will contain the NaCl<br />

Elution – Pipette 500µL 0.4% TFA and 500µL Acetonitrile containing 0.4% TFA onto top<br />

of sorbent bed in spe tube. Run vacuum @ approximately -10 kPa, eluting sample from<br />

sorbent column, continue to apply vacuum until tube is dry.<br />

Column: ProSphere 300 C4-300, 5µm, 150 x 4.6mm<br />

(Part No. 33989)<br />

Mobile Phase: A: 0.2% Trifluoroacetic Acid B: Acetonitrile<br />

Gradient: Time: 0 15<br />

%B: 25 70<br />

Flow Rate: 1mL/min<br />

Detector: ELSD<br />

1<br />

2<br />

0 1 2 3 4 5 6 7 8 9 Min.<br />

3<br />

1. Chloride<br />

2. Ribonuclease A<br />

3. Cytochrome C<br />

10688<br />

Protein Extraction of Ribonuclease and Myoglobin<br />

Procedure using Vydac ® SPE:<br />

A 3mL SPE cartridge was conditioned with 1mL of Acetonitrile followed by 1mL of<br />

5% Acetonitrile/0.1% Trifluoroacetic Acid. Ribonuclease and myglobin (100mg each)<br />

were then loaded in 30% Acetonitrile/0.1% Trifluoroacetic Acid . The cartridge was<br />

washed with 1mL of 5% Acetonitrile/0.1% Trifluoroacetic Acid to remove weakly bound<br />

compounds, then 1mL of 30% Acetonitrile/0.1% Trifluoroacetic Acid followed by 1mL of<br />

60% Acetonitrile/0.1% Trifluoroacetic Acid. HPLC analysis of the 5% Acetonitrile wash<br />

(A) revealed only a small amount of ribonuclease. Most of the ribonuclease eluted in the<br />

30% Acetonitrile wash (B). The myoglobin eluted almost entirely in the 60% Acetonitrile<br />

wash (C).<br />

Solid Phase Extraction Example<br />

A. 5% ACN<br />

1<br />

2<br />

1. Ribonuclease<br />

1. ribonuclease<br />

2. Myoglobin<br />

2. myoglobin<br />

life science<br />

Column: Vydac ® C4, 5µm, 50 x 4.6mm (Part No. 214TP5405)<br />

Mobile Phase: A: 0.1% Trifluoroacetic Acid B: Acetonitrile<br />

Gradient: Time: 0 10<br />

%B: 15 70<br />

B. 30% ACN<br />

C. 60% ACN<br />

0 2 4 6 8 10 Min.<br />

A 3 mL SPE cartridge was conditioned with 1 mL of ACN followed by 1 mL of 5%<br />

ACN/0.1% TFA. Ribonuclease and myglobin (100 mg each) were then loaded in 30%<br />

ACN/0.1% TFA . The cartridge was washed with 1 mL of 5% ACN/0.1% TFA to remove<br />

weakly bound compounds, then 1 mL of 30% ACN/0.1% TFA followed by 1 mL of 60%<br />

ACN/0.1% TFA. HPLC analysis of the 5% ACN wash (A) revealed only a small amount<br />

of ribonuclease. Most of the ribonuclease eluted in the 30% ACN wash (B). The<br />

myoglobin eluted almost entirely in the 60% ACN wash (C).<br />

Column:<br />

Gradient:<br />

VYDAC 214TP5405 (C4, 5 µm, 4.6 mm i.d. x 50 mm)<br />

15 to 70% ACN over 10 min, with 0.1% TFA<br />

498<br />

www.discoverysciences.com


spe applications<br />

Pesticides<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 500mg:<br />

Sample Treatment – Homogenize 5 grams green bell pepper with 25mL methanol, spike<br />

with 0.5μg each of 16 chlorinated pesticides. Filter with 75mL filter column (Part No.<br />

210775). Dilute to 200mL with DI water and shake.<br />

Conditioning – 2 x 5mL methanol, then 5mL DI water.<br />

Sample Application – Attach 75mL reservoir (Part No. 210575) with a syringe adapter<br />

(Part No. 210705) and apply entire sample.<br />

Wash – No wash, apply vacuum for 5 min.<br />

Elution – Elute chlorinated pesticides with 2 x 1mL n-hexane/CH2Cl2 (70:30),<br />

evaporated this to dryness and reconstituted with 1mL n-hexane.<br />

Chlorinated Pesticides in Vegetables<br />

1. a-BHC<br />

2. b-BHC<br />

3. g-BHC<br />

4. d-BHC<br />

5. Heptachlor<br />

6. Aldrin<br />

7. Heptachlor Epoxide<br />

8. Endosulfan I<br />

9. p,p’-DDE<br />

7 8<br />

5<br />

1 23 4 6 9 10 1215<br />

11 16 13<br />

2780<br />

10. Dieldrin<br />

2789<br />

11. Endrin<br />

12. Endosulfan II<br />

13. p,p’-DDD<br />

14. Endrin Aldehyde<br />

15. p,p’-DDT<br />

16. Endosulfan Sulfate<br />

14<br />

After SPE<br />

Clean-up<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

160°C (0 min hold) at 10°C/min, then to 275°C at 5°C/min<br />

Carrier Gas: Helium at 0.8mL/min (26cm/sec)<br />

Detector: ECD at 310°C<br />

Before SPE<br />

Clean-up<br />

0 5 10 15 20 25 30 35 Min.<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 500mg:<br />

Sample Treatment – Weighed out 5 grams dry soil, spike with 1μg each of 16<br />

chlorinated pesticides, add added 25mL methanol and homogenize. Filter with 75mL<br />

filter column (Part No. 210775). Dilute to 200mL with DI water and shake.<br />

Conditioning – 2 x 5mL methanol, then 5mL DI water.<br />

Sample Application – Attach 75mL reservoir (Part No. 210575) with a syringe adapter<br />

(Part No. 210705) and apply entire sample.<br />

Wash – No wash.<br />

Elution – Elute chlorinated pesticides with 2 x 1mL n-hexane/CH2Cl2 (70:30), evaporate<br />

to dryness and reconstitute with 1mL iso-octane.<br />

Chlorinated Pesticides in Soil<br />

1. a-BHC<br />

2. b-BHC<br />

3. g-BHC<br />

4. d-BHC<br />

5. Heptachlor<br />

6. Aldrin<br />

7. Heptachlor Epoxide<br />

8. Endosulfan I<br />

9. p,p’-DDE<br />

10. Dieldrin<br />

1 2<br />

3<br />

4<br />

2779<br />

11. Endrin<br />

2788<br />

12. Endosulfan II<br />

13. p,p’-DDD<br />

14. Endrin Aldehyde<br />

15. p,p’-DDT<br />

16. Endosulfan Sulfate<br />

7 8<br />

5<br />

9 11 12<br />

6 10<br />

13 1415+16 After SPE<br />

After SPE<br />

Clean-up<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

160°C (0 min hold) at 10°C/min, then to 275°C at 5°C/min<br />

Carrier Gas: Helium at 0.8mL/min (26cm/sec)<br />

Detector: ECD at 310°C<br />

Before SPE<br />

Clean-up<br />

0 5 10 15 20 25 30 35 Min.<br />

PCBs in Transformer Oil<br />

Procedure using <strong>Grace</strong>Pure Florisil ® , 1000mg:<br />

Sample Treatment – Dissolve 0.25grams of transformer oil spiked with Aroclor 1254 (at<br />

a concentration of 50mg/kg) in 20mL n-hexane.<br />

Conditioning – 2 x 5mL n-hexane, making sure the cartridge does not dry.<br />

Sample Application – Attach 25mL reservoir (Part No. 210425) with a syringe adapter<br />

(Part No. 210705) and run sample through conditioned Florisil ® tube, aspirating all the<br />

solution from the tube. Evaporate the volume down to 4mL and analyzed by GC/ECD.<br />

Wash – No wash.<br />

Elution – No elution, collect sample load.<br />

1. Aroclor 1254<br />

2784<br />

environmental<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

150°C (2 min hold) to 300°C (8 min hold) at 5°C/min<br />

Carrier Gas: Helium at 0.75mL/min (25cm/sec)<br />

Detector: ECD at 310°C<br />

Clean-up<br />

0 5 10 15 20 25 30 35 40 Min.<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

499


spe applications<br />

Pesticides<br />

Procedure using <strong>Grace</strong>Pure C18-Fast, 1000mg:<br />

Sample Treatment – Weigh out 2.5 grams salmon, spike with 2.5μg Aroclor 1242, add<br />

25mL acetonitrile, homogenize for 30 seconds. Filter with 75mL filter tube (Part No.<br />

210775). Rinse salmon again with 5mL acetonitrile. Bring up to 100mL with deionized<br />

water.<br />

Conditioning – Rinse with 6mL hexanes, 6mL acetone, 2 x 6mL methanol, 2 x 6mL<br />

water.<br />

Sample Application – Attach 75mL reservoir, apply entire sample.<br />

Wash – 2 x 5mL water. Dry columns for 10 minutes at full vacuum.<br />

Elution – Elute PCBs with 2 x 3mL 3% toluene/97% n-hexane. Evaporate<br />

solvent and reconstitute in 1mL n-hexane.<br />

PCBs in Salmon<br />

1. Aroclor 1242<br />

After SPE<br />

Clean-up<br />

2781<br />

2787<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

150°C (2 min hold) to 300°C (2 min hold) at 5°C/min<br />

Carrier Gas: Helium at 0.75mL/min (25cm/sec)<br />

Detector: ECD at 310°C<br />

0 5 10 15 20 25 30 35 40 Min.<br />

Before SPE<br />

Clean-up<br />

Procedure using <strong>Grace</strong>Pure C18-Fast, 1000mg:<br />

Conditioning – Rinse device with 5mL of methanol followed by 5mL deionized water.<br />

Sample Application – Pass 100mL–500mL (containing 1% methanol) of water sample<br />

through the device at 20mL/minute.<br />

Wash – Wash device with 10mL of deionized water then 10mL of methanol:deionized<br />

water (20:80). Remove excess by passing air through the device for two minutes.<br />

Elution – Elute with 2mL of hexane:ethyl acetate (70:30). Pass extract through 2g–3g<br />

sodium sulfate to remove residual water.<br />

Column: AT Pesticide 20m x 0.53mm x 0.60µm Capillary GC<br />

Column (Part No. 16846)<br />

Temp: 210°C<br />

Carrier Gas: Helium, 35cm/sec<br />

Detector: ECD<br />

Chlorinated Pesticides from Water<br />

3<br />

1 2<br />

5<br />

4<br />

7<br />

6 8 9<br />

10 12<br />

11<br />

13<br />

14<br />

18<br />

15<br />

16 17<br />

0 9 18 Min.<br />

1668<br />

Recovery (as % Standard)<br />

1. a-BHC (104%)<br />

2. Lindane (109%)<br />

3. β-BHC (106%)<br />

4. Heptachlor (92%)<br />

5. δ-BHC (110%)<br />

6. Aldrin (98%)<br />

7. Heptachlor Epoxide (107%)<br />

8. α-Endosulfan (105%)<br />

9. p,p'-DDE (79%)<br />

10. Dieldrin (102%)<br />

11. Endrin (104%)<br />

12. p,p'-DDD (92%)<br />

13. β-Endosulfan (103%)<br />

14. p,p'-DDT<br />

15. Endrin Aldehyde (102%)<br />

16. Endosulfan Sulfate (103%)<br />

17. Methoxychlor (99%)<br />

18. Endrin Ketone (104%)<br />

environmental<br />

Procedure using <strong>Grace</strong>Pure C18-Fast, 500mg:<br />

Sample Treatment – Spike 500mL tap water with 125µL carbamate solution for final<br />

concentration of 25ppb.<br />

Conditioning – Rinse with 3mL acetonitrile:water (80:20) followed by 3mL water. Dry<br />

with vacuum.<br />

Sample Application – Apply 500µL sample.<br />

Wash – 2 x 3mL water.<br />

Elution – Elute with 4 x 1mL acetonitrile:water (80:20)<br />

Column: Platinum EPS C18, 5μm, 250 x 4.6mm (Part No. 32246)<br />

Mobile Phase: A: DI water B: Acetonitrile<br />

Gradient: Time: 0 5 20 25 30<br />

%B: 25 25 50 50 25<br />

Flow Rate: 1mL/min<br />

Detector: UV at 210nm<br />

Carbamate Pesticides from Water<br />

1. Aldicarb sulfoxide<br />

2. Methomyl<br />

3. 3-Hydroxycarbofuran<br />

4. Propoxur<br />

5. Carbaryl<br />

6. Methiocarb<br />

2 3<br />

1<br />

0 5 10 15 20 25 Min.<br />

4<br />

5<br />

6<br />

After SPE<br />

Concentration<br />

Before SPE<br />

Concentration<br />

10599<br />

10600<br />

500<br />

www.discoverysciences.com


spe applications<br />

PAHs<br />

Procedure using <strong>Grace</strong>Pure C18-Max:<br />

Sample Treatment – 500mL of water and add 75mL of 2-propanol,<br />

spiked with 20uL of PAH mixture at 2000ug/mL of each PAH, which corresponds to<br />

40ug/500mL water, or 80ppb of each PAH.<br />

Conditioning – 2 x 5mL of methanol, then 5mL of 85% water/<br />

15% 2-propanol.<br />

Sample Application – Attach 75mL reservoir (Part No. 210575) with a<br />

syringe adapter (Part No. 210705) and apply entire sample. Dry<br />

columns for 30 minutes at full vacuum.<br />

Wash – No wash.<br />

Elution – Elute PAHs with 3 x 1mL CH2Cl2 and adjusted the volume<br />

to 1mL by evaporating under a gentle nitrogen stream.<br />

PAHs in Water<br />

1<br />

2 3<br />

4<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. Acenaphthene<br />

4. Fluorene<br />

5. Phenanthrene<br />

6. Anthracene<br />

7. Fluoranthene<br />

8. Pyrene<br />

5 6<br />

7 8<br />

9. Benzo(a)anthracene<br />

10. Chrysene<br />

11. Benzo(b)fluoranthene<br />

12. Benzo(k)fluoranthene<br />

13. Benzo(a)pyrene<br />

14. Indeno(1,2,3-cd)pyrene<br />

15. Dibenzo(a,h)anthracene<br />

16. Benzo(ghi)perylene<br />

14 15<br />

16<br />

11<br />

9<br />

10 12 13<br />

2771<br />

2772<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

80°C (1 min hold) to 160°C (0 min hold) at 25°C/min,<br />

then to 300°C (0 min hold) at 3°C/min, then to 325°C<br />

(3 min hold) at 25°C/min<br />

Carrier Gas: Helium at 1mL/min (28cm/sec)<br />

Detector: FID at 340°C<br />

After SPE<br />

Clean-up<br />

Before SPE<br />

Clean-up<br />

0 5 10 15 20 25 30 35 40 45 50 Min.<br />

PAHs in Toasted Oat Cereal<br />

Procedure using <strong>Grace</strong>Pure C18-Max:<br />

Sample Treatment – 500mL of water and add 75mL of 2-propanol, spiked with 20uL of<br />

PAH mixture at 2000ug/mL of each PAH, which corresponds to 40ug/500mL water, or<br />

80ppb of each PAH.<br />

Conditioning – 2 x 5mL of methanol, then 5mL of 85% water/15% 2-propanol.<br />

Sample Application – Attach 75mL reservoir (Part No. 210575) with a syringe adapter<br />

(Part No. 210705) and apply entire sample. Dry columns for 30 minutes at full vacuum.<br />

Wash – 2 x 500µL of 85% water/15% isopropyl alcohol. Vacuum 10 min.<br />

Elution – Elute PAHs with 3 x 1mL CH2Cl2 and adjusted the volume to 1mL by<br />

evaporating under a gentle nitrogen stream.<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. Acenaphthene<br />

4. Fluorene<br />

5. Phenanthrene<br />

6. Anthracene<br />

7. Fluoranthene<br />

8. Pyrene<br />

1<br />

8<br />

9. Benzo(a)anthracene<br />

10. Chrysene<br />

11. Benzo(b)fluoranthene<br />

12. Benzo(k)fluoranthene<br />

13. Benzo(a)pyrene<br />

14. Indeno(1,2,3-cd)pyrene<br />

15. Dibenzo(a,h)anthracene<br />

16. Benzo(ghi)perylene<br />

16<br />

15<br />

14<br />

2775<br />

2791<br />

2 3<br />

4<br />

5 6 7<br />

11 13<br />

9 12<br />

10<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

80°C (1 min hold) to 160°C (0 min hold) at 25°C/min,<br />

then to 300°C (0 min hold) at 3°C/min, then to 325°C<br />

(3 min hold) at 25°C/min<br />

Carrier Gas: Helium at 1mL/min (28cm/sec)<br />

Detector: FID at 340°C<br />

Before SPE<br />

Clean-up<br />

0 5 10 15 20 25 30 35 40 45 50 Min.<br />

After SPE<br />

Clean-up<br />

environmental<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

501


spe applications<br />

PAHs<br />

PAHs in Cooking Oil<br />

2776<br />

2792<br />

Procedure using DVB Extract-Clean, 500mg/4mL:<br />

Sample Treatment – Weigh out 1 grams canola oil, spike with 20μg of each PAH, add<br />

10mL n-hexane.<br />

Conditioning – 10mL toluene, applied vacuum until toluene removed, then 5mL n-hexane.<br />

Sample Application – Aspirate the entire canola oil/hexane/PAH solution through the tube.<br />

Wash – 5mL n-hexane.<br />

Elution – Elute PAHs with 4 X 2.5mL toluene and adjusted the sample volume to 0.5mL<br />

(500μL) by evaporating under dry nitrogen stream and gentle heat.<br />

1. Naphthalene<br />

2. Acenaphthylene<br />

3. Acenaphthene<br />

4. Fluorene<br />

5. Phenanthrene<br />

6. Anthracene<br />

7. Fluoranthene<br />

8. Pyrene<br />

9. Benzo(a)anthracene<br />

10. Chrysene<br />

11. Benzo(b)fluoranthene<br />

12. Benzo(k)fluoranthene<br />

13. Benzo(a)pyrene<br />

14. Indeno(1,2,3-cd)pyrene<br />

15. Dibenzo(a,h)anthracene<br />

16. Benzo(ghi)perylene<br />

15 16<br />

14<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

80°C (1 min hold) to 160°C (0 min hold) at 25°C/min,<br />

then to 300°C (0 min hold) at 3°C/min, then to 325°C<br />

(3 min hold) at 25°C/min<br />

Carrier Gas: Helium at 1mL/min (28cm/sec)<br />

Detector: FID at 340°C<br />

1<br />

8<br />

2<br />

3 4 56 7<br />

9 10 1112 13<br />

After SPE<br />

Concentration<br />

Before SPE<br />

Concentration<br />

0 5 10 15 20 25 30 35 40 45 50 55 Min.<br />

environmental<br />

Nitroaromatics<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 500mg:<br />

Sample Treatment – Spike 100g soil with 7.5µg/g of each analyte. Combine soil with<br />

1000mL deionized water, shake for 10 minutes, and filter.<br />

Conditioning – Rinse device with 5mL methanol followed by 5mL water.<br />

Sample Application – Aspirate 1000mL water sample through SPE at flow rate 1-<br />

5mL/min.<br />

Wash – No wash. Air dry for 15 seconds.<br />

Elution – Elute with three 1mL aliquots of methanol:water (50:50). Air dry<br />

for 15 seconds between each elution.<br />

Column: Adsorbosphere UHS C18, 5µm, 150m x 4.6mm<br />

(Part No. 288118)<br />

Mobile Phase: Methanol:Water (50:50)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

Nitroaromatics and Naphthols from Soil<br />

1<br />

Before SPE<br />

Concentration<br />

0 5 10 15 20 25 30 35 Min.<br />

2<br />

3<br />

4<br />

5<br />

6<br />

1. 2,4-Dinitrotoluene<br />

2. 1-Naphthol<br />

3. 2-Naphthol<br />

4. 2-Nitrotoluene<br />

5. 4-Nitrotoluene<br />

6. 3-Nitrotoluene<br />

After SPE<br />

Concentration<br />

10597<br />

10598<br />

502<br />

www.discoverysciences.com

Hooray! Your file is uploaded and ready to be published.