analytical hplc<br />

hplc columns | small molecule<br />

<strong>Grace</strong> ® VisionHT Ultra High-Pressure Columns<br />

See Separations with Speed and Clarity<br />

• Ultra-fast separations with superior efficiency, sensitivity, and resolution<br />

• Exceptional stability for long column lifetimes<br />

• Comprehensive sub 2μm stationary phase offering<br />

• 12,000psig pressure rating compatible with all ultra high-pressure LC systems<br />

<strong>Grace</strong> ® VisionHT columns offer a new level of performance in HPLC. The powerful combination of<br />

high-strength 1.5µm media with ultra-low volume hardware, delivers new clarity to your separations<br />

and maintains exceptional column lifetime. Complex samples resolve 95% faster with 4x greater<br />

sensitivity when compared to traditional 2.1 x 150mm, 5µm columns. And with a wide variety of<br />

phases available, the possibilities are endless.<br />

2500 mAU<br />

2000<br />

1500<br />

1000<br />

500<br />

2500 mAU<br />

0<br />

0<br />

2000<br />

0<br />

0<br />

2<br />

1500<br />

1<br />

3<br />

1000<br />

4<br />

500<br />

1 2<br />

2<br />

3<br />

2 4 6 8 10 12 14 Min.<br />

Increase Speed by 95% and Gain 4x Better Sensitivity<br />

Column: VisionHT C18, 1.5µm,<br />

2.0 x 50mm<br />

Flow Rate: 0.8mL/min<br />

4<br />

2500 mAU<br />

2000<br />

1500<br />

1000<br />

4 6 8 10 12 14 Min.<br />

Column: Traditional C18, 5µm, 2.1 x 150mm<br />

Flow Rate: 0.2mL/min<br />

500<br />

0<br />

1<br />

2<br />

3<br />

4<br />

Impurities<br />

not seen on<br />

traditional<br />

5µm columns.<br />

0 0.5 1 1.5 2 Min.<br />

1. Thiourea<br />

2. Toluene<br />

3. Propylbenzene<br />

4. Butylbenzene<br />

System: Agilent 1200<br />

Mobile Phase: (45:55) 20mM Potassium Phosphate,<br />

pH 2.5:Acetonitrile<br />

Detector: UV at 254nm<br />

Temperature: Ambient<br />

Efficiency and Retention Times Remain Constant after Exposure to 12,000psig and 2000 Injections<br />

Plates/Meter (000)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

Column Stability Comparison, 50 x 2mm<br />

VisionHT Column 1<br />

VisionHT Column 2<br />

VisionHT Column 3<br />

VisionHT Column 4<br />

Column Volumes<br />

VisionHT Column 5<br />

VisionHT Column 6<br />

VisionHT Column 7<br />

Competitor Sub 2µm Column<br />

Competitor<br />

Sub 2µm Column<br />

1<br />

2+3<br />

1<br />

2+3<br />

4<br />

4 6<br />

5<br />

5<br />

0 2 4 6 8 Min.<br />

6<br />

1. Uracil<br />

2. Pyridine<br />

3. Phenol<br />

4. Methyl Alanine<br />

5. 4-Butyl Benzoic Acid<br />

6. Toluene<br />

Initial<br />

FINAL<br />

(After 2000 injections)<br />

0 2 4 6 8 Min.<br />

Column: 2.0 x 50mm<br />

Mobile Phase: 50mM KH2PO4, pH 7.0:CH3CN (60:40)<br />

Flow Rate: 1.0mL/min<br />

High-pressure competitor sub 2µm column lost efficiency at routine<br />

12,000psig pressures. VisionHT columns remain stable.<br />

Before and after chromatograms show a constant level of<br />

performance after 2000 injections.<br />