13.04.2015 Views

Grace Catalog 2008

Grace Catalog 2008

Grace Catalog 2008

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

prep | flash | tlc<br />

TLC Accessories<br />

TLC Plate Cutter<br />

• Scores coated glass plates at<br />

any position<br />

• Compact, portable, and easy<br />

to operate<br />

The TLC Plate Cutter has a highquality<br />

carbide scriber mounted<br />

into a movable plastic head. It is designed to produce optimal<br />

scoring on the glass surface of 20 x 20cm TLC plates with a<br />

total thickness (glass + coating) of 2mm. A smaller template<br />

is included with the unit for ease in cutting 10 x 10cm plates.<br />

3923<br />

TLC Spotting Guide<br />

This template fits over a standard 20 x 20cm<br />

TLC plate. 1cm divisions allow for accurate<br />

sample application. After development,<br />

a series of labelled circles and lines on<br />

the template helps to estimate areas or<br />

to measure distances for Rƒ calculations.<br />

best<br />

seller<br />

Spotting Accessories<br />

Description Qty. Part No.<br />

TLC Spotting Guide ea 7624<br />

4128<br />

tlc<br />

TLC Plate Cutter<br />

Description Qty. Part No.<br />

TLC Plate Cutter ea 7535<br />

Replacement Scribers 1 7565<br />

3 7575<br />

tech tip<br />

Note About Sample Applications<br />

Thorough drying of samples is a step that is often ignored but can<br />

result in development errors. If a small amount of solute is left on<br />

the plate it can interact with the development system and affect<br />

the separation.<br />

Many analysts assume the plate is dry when the solvent is no<br />

longer visible on the plate (5–10 minutes). However, depending<br />

on the volatility of the solvent and the quantity of sample applied,<br />

the drying time can be considerably longer. Generally, Rƒ values<br />

decrease as drying time increases until the dry state (stable Rƒ)<br />

is reached.<br />

Plates can absorb moisture from the atmosphere during storage,<br />

so prior to sample application, all TLC plates should be heated<br />

at 120–130°C for about 30–40 minutes and allowed to cool in<br />

a desiccator. This ensures reproducible Rƒ values.<br />

Universal Spotting Template<br />

• Use to cut channels or to spot plates<br />

• Measure Rƒ values<br />

• Non-slip surface works with any size<br />

TLC plates<br />

Spotting Accessories<br />

Description Qty. Part No.<br />

Universal Spotting Template ea 26270<br />

TLC Plate Coating Supplies<br />

• Desaga plate coating device<br />

and template<br />

• Adsorbosil ® -Plus powders and<br />

polished glass plates<br />

Plate Coating Supplies<br />

Description Qty. Part No.<br />

Desaga Plate Spreading Device and Template<br />

Plate Spreading Device ea 95116<br />

Plate Spreading Template ea 95118<br />

Polished Glass Plates<br />

20 x 20cm Plate, 3mm Thick 10 26080<br />

Alltech ® Adsorbosil ® Powders<br />

Adsorbosil ® -Plus 1 1lb 160201<br />

Macherey-Nagel Powders<br />

Cellulose MN 301 1000g 81605<br />

4130<br />

5384<br />

TLC Plate Scriber<br />

• Cuts channels in soft and hard layers<br />

• Adjust channel widths in multiples<br />

of 1cm<br />

• Made of flexible stainless steel<br />

Spotting Accessories<br />

Description Qty. Part No.<br />

TLC Plate Scriber ea 17102<br />

4132<br />

196 www.discoverysciences.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!