13.04.2015 Views

Grace Catalog 2008

Grace Catalog 2008

Grace Catalog 2008

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

spe applications<br />

Pesticides<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 500mg:<br />

Sample Treatment – Homogenize 5 grams green bell pepper with 25mL methanol, spike<br />

with 0.5μg each of 16 chlorinated pesticides. Filter with 75mL filter column (Part No.<br />

210775). Dilute to 200mL with DI water and shake.<br />

Conditioning – 2 x 5mL methanol, then 5mL DI water.<br />

Sample Application – Attach 75mL reservoir (Part No. 210575) with a syringe adapter<br />

(Part No. 210705) and apply entire sample.<br />

Wash – No wash, apply vacuum for 5 min.<br />

Elution – Elute chlorinated pesticides with 2 x 1mL n-hexane/CH2Cl2 (70:30),<br />

evaporated this to dryness and reconstituted with 1mL n-hexane.<br />

Chlorinated Pesticides in Vegetables<br />

1. a-BHC<br />

2. b-BHC<br />

3. g-BHC<br />

4. d-BHC<br />

5. Heptachlor<br />

6. Aldrin<br />

7. Heptachlor Epoxide<br />

8. Endosulfan I<br />

9. p,p’-DDE<br />

7 8<br />

5<br />

1 23 4 6 9 10 1215<br />

11 16 13<br />

2780<br />

10. Dieldrin<br />

2789<br />

11. Endrin<br />

12. Endosulfan II<br />

13. p,p’-DDD<br />

14. Endrin Aldehyde<br />

15. p,p’-DDT<br />

16. Endosulfan Sulfate<br />

14<br />

After SPE<br />

Clean-up<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

160°C (0 min hold) at 10°C/min, then to 275°C at 5°C/min<br />

Carrier Gas: Helium at 0.8mL/min (26cm/sec)<br />

Detector: ECD at 310°C<br />

Before SPE<br />

Clean-up<br />

0 5 10 15 20 25 30 35 Min.<br />

Procedure using <strong>Grace</strong>Pure C18-Max, 500mg:<br />

Sample Treatment – Weighed out 5 grams dry soil, spike with 1μg each of 16<br />

chlorinated pesticides, add added 25mL methanol and homogenize. Filter with 75mL<br />

filter column (Part No. 210775). Dilute to 200mL with DI water and shake.<br />

Conditioning – 2 x 5mL methanol, then 5mL DI water.<br />

Sample Application – Attach 75mL reservoir (Part No. 210575) with a syringe adapter<br />

(Part No. 210705) and apply entire sample.<br />

Wash – No wash.<br />

Elution – Elute chlorinated pesticides with 2 x 1mL n-hexane/CH2Cl2 (70:30), evaporate<br />

to dryness and reconstitute with 1mL iso-octane.<br />

Chlorinated Pesticides in Soil<br />

1. a-BHC<br />

2. b-BHC<br />

3. g-BHC<br />

4. d-BHC<br />

5. Heptachlor<br />

6. Aldrin<br />

7. Heptachlor Epoxide<br />

8. Endosulfan I<br />

9. p,p’-DDE<br />

10. Dieldrin<br />

1 2<br />

3<br />

4<br />

2779<br />

11. Endrin<br />

2788<br />

12. Endosulfan II<br />

13. p,p’-DDD<br />

14. Endrin Aldehyde<br />

15. p,p’-DDT<br />

16. Endosulfan Sulfate<br />

7 8<br />

5<br />

9 11 12<br />

6 10<br />

13 1415+16 After SPE<br />

After SPE<br />

Clean-up<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

160°C (0 min hold) at 10°C/min, then to 275°C at 5°C/min<br />

Carrier Gas: Helium at 0.8mL/min (26cm/sec)<br />

Detector: ECD at 310°C<br />

Before SPE<br />

Clean-up<br />

0 5 10 15 20 25 30 35 Min.<br />

PCBs in Transformer Oil<br />

Procedure using <strong>Grace</strong>Pure Florisil ® , 1000mg:<br />

Sample Treatment – Dissolve 0.25grams of transformer oil spiked with Aroclor 1254 (at<br />

a concentration of 50mg/kg) in 20mL n-hexane.<br />

Conditioning – 2 x 5mL n-hexane, making sure the cartridge does not dry.<br />

Sample Application – Attach 25mL reservoir (Part No. 210425) with a syringe adapter<br />

(Part No. 210705) and run sample through conditioned Florisil ® tube, aspirating all the<br />

solution from the tube. Evaporate the volume down to 4mL and analyzed by GC/ECD.<br />

Wash – No wash.<br />

Elution – No elution, collect sample load.<br />

1. Aroclor 1254<br />

2784<br />

environmental<br />

Column: AT 5ms, 0.25µm, 30m x 0.25mm (Part No. 15807)<br />

Temp:<br />

150°C (2 min hold) to 300°C (8 min hold) at 5°C/min<br />

Carrier Gas: Helium at 0.75mL/min (25cm/sec)<br />

Detector: ECD at 310°C<br />

Clean-up<br />

0 5 10 15 20 25 30 35 40 Min.<br />

more applications<br />

View our complete searchable chromatogram database at www.discoverysciences.com/chromdb/<br />

ww.discoverysciences.com<br />

499

Hooray! Your file is uploaded and ready to be published.