13.04.2015 Views

Grace Catalog 2008

Grace Catalog 2008

Grace Catalog 2008

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

hplc applications<br />

pharmaceuticals<br />

Bronchodilators<br />

Bronchodilators<br />

Bronchodilators<br />

3<br />

4<br />

1<br />

5<br />

1. Uracil<br />

2. Salbutamol<br />

3. Terbutaline<br />

4. Theophylline<br />

5. Pseudoephedrine<br />

1<br />

2<br />

3<br />

Analysis of Broncholytics -<br />

Xanthines<br />

4<br />

5<br />

1. Theobromine<br />

2. Theophylline<br />

3. β-Hydroxyethyltheophylline<br />

4. 7-β-Hydroxypropyltheophyline<br />

5. Caffeine<br />

2<br />

0 1 2 3 4 Min.<br />

Column: Jones Genesis ® Phenyl, 4µm, 150 x 4.6mm<br />

Column: GENESIS (Part FM15980E No. FM5980E) (Phenyl, 4 µm, 4.6 mm i.d. x 150 mm)<br />

Flow: Mobile Phase: 2.0 mL/min Acetonitrile:25mM KH2PO4, pH3.0 (10:90)<br />

Eluent: Flow Rate: Isocratic, 2.0mL/min 10% ACN in 25 mM KH 2 PO 4 , pH3.0<br />

Detection: Detector: Absorbance, UV at 220nm<br />

Peaks: 1. Uracil, 2. Salbutamol, 3. Terbutaline, 4. Theophylline,<br />

5. Pseudoephedrine<br />

Xanthines<br />

2<br />

1<br />

3<br />

4<br />

5<br />

6 7<br />

0 2 4 6 8 10 Min.<br />

1. Uracil<br />

2. Theobromine<br />

3. Impurity<br />

4. Sodium Benzoate<br />

5. Theophylline<br />

6. b-Ethoxytheophylline<br />

7. Caffeine<br />

Xanthines<br />

0 3 6 9 12 Min.<br />

Column: Grom Sil 120 ODS-4 HE, 5μm, 250 x 4mm<br />

(Part No. 5113626)<br />

Mobile Phase: 0.4% Sodium Acetate:Acetonitrile (85:15)<br />

Flow Rate: 0.8mL/min<br />

Detector: UV at 254nm<br />

Column:<br />

Mobile Phase:<br />

Flow Rate:<br />

Detector:<br />

Jones Genesis ® C18, 4µm, 150 x 4.6mm<br />

(Part No. FM15960E)<br />

Acetonitrile:50mM Aqueous Ammonium Acetate, pH4.7<br />

(12:88)<br />

1.0mL/min<br />

UV at 254nm<br />

Column: GENESIS FM15960E (C18, 4 µm, 4.6 mm i.d. x 150 mm)<br />

Flow:<br />

1.0 mL/min<br />

Eluent: Antifungal Isocratic, 12% ACN in 50 mM NH 4 OAc, pH 4.7<br />

Detection: Absorbance, 254 nm<br />

Lotrimin ® Topical Assay<br />

Peaks: 1. Uracil, 2. Theobromine, 3. Impurity, 4. Sodium Benzoate,<br />

5. Theophylline, 6. b-Ethoxytheophylline, 7. Caffeine<br />

1<br />

2<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 Min.<br />

1. PEG<br />

2. Clotrimazole<br />

10447<br />

Column: Alltech ® Alltima C18, 5µm, 150 x 4.6mm (Part No. 88302)<br />

Mobile Phase: A: Water to pH7.0 with Acetic Acid B: Methanol<br />

Gradient: Time: 0 8 10 20 25<br />

%B: 30 50 100 100 30<br />

Flow Rate: 1.0mL/min<br />

Detector: ELSD<br />

mAU<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

Griseofulvin Assay on Chinese Pharmacopeia<br />

0<br />

1. Griseofulvin<br />

2.5 5 7.5 10 12.5 15 17.5 20 22.5 Min.<br />

Competitor 1 C18<br />

Competitor 2 C18<br />

Competitor 3 C18<br />

10772<br />

Competitor 4 C18<br />

Competitor 5 C18<br />

<strong>Grace</strong>Smart C18<br />

Column: <strong>Grace</strong>Smart C18, 5µm, 250 x 4.6mm (Part No. 5138810)<br />

Mobile Phase: 0.05mol/L Potassium Dihydrogen Phosphate:<br />

Acetonitrile:Methanol (57:38:5)<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 254nm<br />

408<br />

www.discoverysciences.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!