prep | flash | tlc<br />

<strong>Grace</strong>Alpha Columns<br />

A New Silica Generation<br />

new<br />

• High-porosity surface increases mass transfer and results<br />

in increased column efficiencies and loading capacity<br />

• Dense core and highly spherical shape yield<br />

mechanically robust particle<br />

• Proprietary bonding technology gives unique selectivity<br />

and increased resolution<br />

<strong>Grace</strong>Alpha Performance<br />

Outstanding Loading Capacity<br />

<strong>Grace</strong>Alpha silica has a high-porosity exterior yielding<br />

higher loading capacities than conventional silicas.<br />

Unique Selectivity<br />

Proprietary bonding chemistry provides unique selectivity that<br />

yields advantages not seen in other C18 and C8 phases.<br />

prep | columns<br />

Norm.<br />

800<br />

600<br />

400<br />

200<br />

Insulin Frontal Loading Capacity<br />

on C8 Columns with 0.1% TFA<br />

Insulin loading capacity is 16 to 1000% higher recovery on<br />

the <strong>Grace</strong>Alpha C8 column.<br />

Competitor A<br />

14 mg/mL<br />

Competitor B<br />

133 mg/mL <strong>Grace</strong>Alpha<br />

154 mg/mL<br />

Peptide Standard Mixture<br />

The <strong>Grace</strong>Alpha column offers selectivity advantages.<br />

1<br />

1<br />

2<br />

2<br />

3 4<br />

5<br />

3 4<br />

5<br />

<strong>Grace</strong>Alpha<br />

Column<br />

Competitor<br />

1. GY (238 Da)<br />

2. VYV (379 Da)<br />

3. Met Enkephalin<br />

(YGGFM, 573 Da)<br />

4. Angiotensin II<br />

(DRVYIHPF, 1045 Da)<br />

5. Leu Enkephalin<br />

(YGGFL, 555 Da)<br />

0<br />

0 20 40 60 80 100 120 140 160 180<br />

Breakthrough Time (min.)<br />

High Resolution and Recovery<br />

<strong>Grace</strong>Alpha columns increase purity and yield of synthetic<br />

peptides with superior resolution of impurities due to higher<br />

mass transfer and optimized C18 and C8 bonding chemistry.<br />

Crude 20-AA Synthetic Peptide<br />

The target peptide is better resolved from impurities, with<br />

33% higher recovery, on the <strong>Grace</strong>Alpha column.<br />

0 6 12 18 24 30 Min.<br />

Columns: All C18, 5µm, 4.6 x 250mm<br />

Mobile Phase: A: 0.1% TFA in Water, B: 0.085% TFA in Acetonitrile<br />

Gradient: Time: 0 30 35 40<br />

%B: 10 40 90 90<br />

Flow Rate: 1.0mL/min<br />

Detector: UV at 225nm<br />

Column Temp.: 25°C<br />

Resolution (USP)*<br />

Peptide Peak <strong>Grace</strong>Alpha Column Competitor<br />

1 42.0 35.7<br />

2 32.2 28.3<br />

3 6.0 2.3<br />

4 7.4 11.3<br />

*Resolution is based on the next adjacent peak.<br />

Better resolution<br />

of closely eluting<br />

impurities<br />

0.00 5.00 10.00 15.00 19.99<br />

Competitor<br />

Column 4µm<br />

<strong>Grace</strong>Alpha<br />

Column 5µm<br />

Columns: All C18, 4.6 x 250mm<br />

Mobile Phase: A: 0.1% TFA in Water, B: 0.1% TFA in Acetonitrile<br />

Gradient: Time: 0 20<br />

%B: 20 40<br />

Flow Rate: 1.0mL/min<br />

Data courtesy of: Biopeptide Inc.<br />

related products<br />

<strong>Grace</strong>Alpha bulk media is also<br />

available for scale-up. See page<br />

176 for more information.<br />

7250<br />

152 www.discoverysciences.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!