analytical hplc<br />

Autosamplers<br />

Alltech ® 570 Autosampler<br />

• Affordably<br />

automate HPLC<br />

and IC analysis<br />

• Flushed loop<br />

filling maximizes<br />

precision and<br />

reproducibility<br />

• Partial loop filling<br />

minimizes sample<br />

waste<br />

Choose between flushed and partial<br />

loop filling and stainless steel and PEEK<br />

fluid paths.<br />

1408<br />

Alltech ® 580 Autosampler<br />

• Automates sample<br />

prep tasks: sample<br />

dilution, derivatization,<br />

and internal standard<br />

addition<br />

• Capable of three<br />

different injection<br />

techniques<br />

• Large injection volume<br />

range for maximum<br />

versatility<br />

• Built-in column heater<br />

Multifunctional autosampler<br />

improves laboratory efficiency.<br />

3000<br />

hplc instruments<br />

570 Autosampler Specifications<br />

Vial Capacity: 96 samples (92 with needle wash), 48 (5mL)<br />

vials (optional)<br />

Injection Volume: Flushed Loop: 5–500µL (dispenser controlled),<br />

5–5000µL (by head space pressure).<br />

Partial Loopfill: 10–490µL in steps of 10µL<br />

(depending on the loop volume, maximum 50%<br />

of the loop volume)<br />

Injections per Vial: 9 Maximum<br />

Needle Wash: Selectable, 50µL fixed volume between vials<br />

Reproducibility: Flushed Loop Injections: RSD≤0.5%<br />

Partial Loop Injections: RSD≤1.0%<br />

Power:<br />

115 VAC/230 VAC; 50/60 Hz<br />

Dimensions:<br />

11.1" H x 11.8" W x 17.3" D<br />

(28cm H x 30cm W x 44cm D)<br />

Weight:<br />

34lb (15.5kg)<br />

Warranty:<br />

1 year<br />

Model 570 Autosampler<br />

Description<br />

Part No.<br />

Flushed Loop Filling<br />

Stainless Steel 575100<br />

PEEK 575500<br />

Partial Loop Filling<br />

Stainless Steel 570150<br />

PEEK 570550<br />

Spare Parts for 570 Autosampler<br />

Description<br />

Part No.<br />

Pump Tubing Cassette 575115<br />

Side-Port Sample Needle, 3/pk 575130<br />

Large Volume Option, Field Installable 575165<br />

Air Needle 575125<br />

Sample Drain for Headspace Pressure 575170<br />

Auxilliary and Control I/O Cable 570101<br />

Tubing from Needle to Valve, 10ft 20064<br />

Needle Connection Nut 575175<br />

Needle Connection Ferrule, 10/pk 575185<br />

Standard Vial Tray 575110<br />

580 Autosampler Specifications<br />

Vial Capacity: 84 (1.5mL) vials + 3 (10mL) vials,<br />

96 (1.5mL) vials (optional),<br />

24 (10mL) vials (optional)<br />

Injection Volume: 1–5000µL in 1µL increments,<br />

5000–7500µL in 1.5µL increments,<br />

7500–10,000µL in 4µL increments<br />

Injections per Vial: 9 maximum<br />

Analysis Time: 9hrs 59min 59sec maximum<br />

Reproducibility: Full Loop Injections: ≤0.3% RSD,<br />

Partial Loop Injections: ≤0.5% RSD,<br />

µL Pick-Up Injections(>10µL):≤1.0%<br />

Carry Over:<br />