analytical hplc<br />

Rheodyne ® Manual Switching Valves<br />

• Inexpensive manual switching valve<br />

• Wide-bore version for prep<br />

Manual Switching Valve Applications<br />

2-Position 6-Port:<br />

Two Column Selection<br />

2-Position 6-Port:<br />

Pre-Column Backflushing<br />

Injector<br />

Injector<br />

hplc accessories | valves<br />

Rheodyne ® HPLC Switching Valves offer an endless variety of<br />

ways to simplify switching and injecting. Standard valves are<br />

supplied with 0.024" internal flow passages and are suitable<br />

for use with analytical and semi-preparative applications.<br />

Large bore valves with 0.040" internal flow passages are<br />

available for use at high flow rates (greater than 50mL/min)<br />

7000psig pressure limit.<br />

A spring detent mechanism included in the 6-position<br />

selection valve permits full circle rotation in either direction<br />

and ensures that the rotor “falls into” each of the six positions<br />

at the precise 60° spacing.<br />

*5000psig pressure rating for 2-position 6-port and 10-port.<br />

5619<br />

6<br />

1<br />

5 4<br />

Detector<br />

2<br />

3<br />

0798<br />

Off line column is sealed. Flow<br />

continues on line.<br />

3-Way Valve:<br />

Column Programming<br />

Analytical Column<br />

6<br />

1<br />

2<br />

5 4<br />

3<br />

Detector<br />

Pre Column<br />

0801<br />

Flow continues through column.<br />

Only pre-column is backflushed.<br />

4-Way Valve:<br />

Column Backflushing<br />

Rheodyne ® Manual Switching Valves<br />

Description Version Bore Part No.<br />

2-Position Valves<br />

6-Port SS Standard 7000RV<br />

6-Port SS Large Bore 7000L<br />

3-Way SS Standard 7030RV<br />

3-Way SS Large Bore 7030L<br />

4-Way SS Standard 7040RV<br />

Multi-Position Valves<br />

6-Position 6-Port SS Standard 7060RV<br />

Column B<br />

Column A<br />

6<br />

1<br />

2<br />

5 4<br />

Detector<br />

3<br />

Injector<br />

Column C<br />

6<br />

1<br />

2<br />

5 4<br />

Detector<br />

3<br />

Injector<br />

0802<br />

0800<br />

related products<br />

Need fittings for valves? See page 141.<br />

Part of sample is analyzed on<br />

columns A-B, the other part on<br />

columns A-C.<br />

Flow is backflushed to direct<br />

peak of interest to detector.<br />

6-Position 6-Port Valve:<br />

Tandem Five Column Selection<br />

Detector<br />

5<br />

4<br />

6<br />

3<br />

1<br />

2<br />

5<br />

4<br />

6<br />

3<br />

1<br />

2<br />

Injector<br />

Bypass Flush-Out Line<br />

Selects between five columns. Use the sixth port for a bypass/flush<br />

out line. Two 7060s are required.<br />

0799<br />