y the client. However, there’s no<br />

such design <strong>in</strong> this type of turb<strong>in</strong>e.<br />

After removed of the cross, the user<br />

was effective that vibration obviously<br />

became slighter and the maximum<br />

output reached 265 kW. In spite<br />

of this, slight vibration still badly impact<br />

turb<strong>in</strong>e’s operation that runner<br />

cone became loose after one hour’s<br />

operation. Further measure seemed<br />

necessary.<br />

Measure 3:<br />

Consider<strong>in</strong>g similarities between<br />

Turb<strong>in</strong>e A and B and after adopt<strong>in</strong>g<br />

the second measure, we exchanged<br />

two mach<strong>in</strong>e’s runner. The result was<br />

that turb<strong>in</strong>e A operated normally, but<br />

turb<strong>in</strong>e B operated with vibration.<br />

Then we tried to run Turb<strong>in</strong>e B with<br />

previous runner (with16 blades),<br />

which resulted <strong>in</strong> no vibration but with<br />

lower output (220kW). The whole<br />

th<strong>in</strong>gs came to obvious that with specialized<br />

hydraulic head, the vortex<br />

alternation, caused by rotational flow<br />

which streamed from outlet side when<br />

guide blades reached certa<strong>in</strong> open<strong>in</strong>g,<br />

came <strong>in</strong>to regular frequency of lateral<br />

alternat<strong>in</strong>g stress on blades as well<br />

as periodic vibration <strong>in</strong>volved with<br />

blades’ boundary ply and velocity of<br />

flow. The same frequency of periodic<br />

vibration and guide blade’s vibration<br />

led to the resonance. That was what<br />

we called Karman Vortex Street. As<br />

the old runner of 16 blades could<br />

hardly reach the aim of capacity<br />

expansion, we redesigned and selected<br />

after comparison HL120 runner<br />

blade type as the new runner.<br />

Turb<strong>in</strong>e vibration, then <strong>in</strong> the test<br />

operation with new runner, disappeared<br />

and bear<strong>in</strong>g temperature had<br />

fallen to 51 . It was important that<br />

the maximal output mounted to<br />

280kW, an <strong>in</strong>crease by 33%. The client<br />

was quite satisfied.<br />

Conclusion<br />

Brief<strong>in</strong>gs<br />

From above efforts and<br />

experience, we may conclude that:<br />

(1) The runner is the l<strong>in</strong>chp<strong>in</strong> <strong>in</strong> capacity<br />

expansion.<br />

(2) Another ma<strong>in</strong> cause to abnormalities<br />

may be <strong>in</strong>appropriate<br />

<strong>in</strong>stallation.<br />

(3) Add<strong>in</strong>g diversion cross at the<br />

draft tube without the design may<br />

lead just the opposite to what one<br />

wishes.<br />

Mr. Liang Sun, is Deputy Director of<br />

Luod<strong>in</strong>g Turb<strong>in</strong>e Plant of Guangdong<br />

Prov<strong>in</strong>ce,Ch<strong>in</strong>a<br />

Translated by D. Pan, HRC(Email:<br />

dqpan@hrcshp.org) from the Ch<strong>in</strong>ese<br />

magaz<strong>in</strong>e—“Small Hydropower” 2003<br />

No1, Total No 109 issue<br />

Ch<strong>in</strong>a’s power sector growth rates 1998-2004<br />

Indicator 1998 1999 2000 2001 2002 2003 2004*<br />

Consumption(% y/y) 2.7 5.9 9.5 8.2 10.4 15.4 12.0<br />

Generation(% y/y) 2.0 6.5 10.9 8.8 10.5 15.3 15.7**<br />

Installed capacity(% y/y) 9.0 7.9 7.0 6.0 4.6 7.8 9.0<br />

GDP(% y/y) 7.8 7.1 8.0 7.5 8.5 9.1 8.7<br />

Power sector <strong>in</strong>vestment/ 10.4 10.4 7.22 6.94 7.17 n/a n/a<br />

total <strong>in</strong>fra. <strong>in</strong>vest.(% share)<br />

* forecast except generation ** Jan-Mar 2004 actual<br />

Peak power by regional network for 21 months, April 2002-December 2003<br />

Network Prov<strong>in</strong>ces *Trend(GW) % change <strong>in</strong> period M<strong>in</strong>-Max <strong>in</strong> period (GW) % ga<strong>in</strong><br />

Dongbei Heiliongjiang<br />

J<strong>in</strong>l<strong>in</strong>, Liaon<strong>in</strong>g 20-12.5 7.5 20-27 35.0<br />

Huabei Nei Mongol, Shanxi 32-35 9.4 32-40 25.0<br />

Hebei, Beij<strong>in</strong>g<br />

Shandong Shandong 13.5-14.8 9.6 13.5-17.6 30.4<br />

Sichuan Sichuan 6.7-7.8 16.4 6.7-10.5 56.7<br />

Nanfang Yunnan, Guizhou 29-34 17.2 29-40 37.9<br />

Guangxi, Guandong<br />

Xibei Q<strong>in</strong>ghai, Gansu, 11-13 18.2 11-16 45.5<br />

Shanxi, N<strong>in</strong>gxia<br />

Huazhong Henan, Hubei, 22-26 18.2 22-35 59.1<br />

Huanan, Jiangxi<br />

Fujian Fujian 6.5-8.0 23.1 6.5-9.2 41.5<br />

Huadong Jiangsu, Shanghai 38-48 26.3 38-57 50.0<br />

Zhejiang<br />

Chongq<strong>in</strong>g Chongq<strong>in</strong>g 2.2-3.0 36.4 2.2-4.4 100.0<br />

* Not shown:X<strong>in</strong>gjiang, Tibet, Anhui, Tianj<strong>in</strong>, Hongkong.<br />

<strong>SHP</strong> <strong>in</strong> Ch<strong>in</strong>a<br />

(Source:Power Eng<strong>in</strong>eer<strong>in</strong>g International)<br />

14 www.hrcshp.org <strong>SHP</strong> NEWS Autumn 2004