<strong>Report</strong> of the Directors<br />

Annexure I to the <strong>Report</strong> of the Directors<br />

Statement of particulars required under the Companies<br />

(Disclosure of Particulars in the <strong>Report</strong> of the Board of<br />

Directors) Rules, 1988<br />

A. Conservation of Energy<br />

(a) Energy Conservation Measures Taken:<br />

1. CFBC of 160t/hr capacity boiler has been<br />

commissioned for utilising the waste char &<br />

coal fines generated from Sponge Iron Plant.<br />

2. Reduction of Coke burning loss in Coke Oven.<br />

3. Reduction in air ingress in flue gas at Coke<br />

Oven resulting in higher steam temperature<br />

and lower specific consumption of steam per<br />

unit power generation.<br />

4. Manganese ore consumption in Blast Furnace<br />

has been stopped & use of magnesite in Ferro<br />

Chrome Plant has been stopped.<br />

5. Zero discharge of waste water.<br />

(b) Additional Investment and Proposals, if any,<br />

being implemented for reduction of consumption<br />

of energy:<br />

1. Coke pusher car track is being repaired for<br />

smooth operation of Coke Oven Plant.<br />

2. Coke pusher no. 2 will be renovated to<br />

improve machine availability.<br />

3. Additional magnetic separator is being<br />

installed in DRI to recover magnetic particles<br />

going into oversize.<br />

(c) Impact of Measures in (a) and (b) above have<br />

resulted in:<br />

1. Saving in electrical energy and higher power<br />

generation.<br />

2. Effective utilisation of waste heats.<br />

3. Effective utilisation of solid waste like char<br />

and coal fines.<br />

(d) Total Energy Consumption and Energy<br />

Consumption per Unit of Production (as per<br />

Form “A” below)<br />

Overview Statutory <strong>Report</strong>s Financial Statements<br />

FORM A<br />

<strong>2010</strong>-<strong>11</strong> 2009-10<br />

A. Power & Fuel Consumption<br />

1. Electricity<br />

(a) Purchased<br />

Unit (Kwh) 19,306,510 35,501,800<br />

Total Amount - (Rs. million) 90.25 131.97<br />

Rate / unit - (Rs.) 4.67 3.72<br />

(b) Own Generation<br />

(i) Through Diesel Generator<br />

Unit (Kwh) 2,816 3,475<br />

Units per ltr. of diesel oil (Kwh) 2.82 2.80<br />

Cost/unit – (Rs.) 14.00 13.92<br />

(ii) Through Steam Turbine / Generator<br />

Unit (Kwh) 225,961,000 223,283,900<br />

Units per ltr. of fuel oil / gas NIL NIL<br />

Cost/units – (Rs.) NA NA<br />

2. Coal (Coking and non-coking coal at Coke Oven,<br />

Ferro Chrome & DRI)<br />

Quantity (MT) 695,187 8<strong>11</strong>,448<br />

Total Cost - (Rs. million) 4,928.77 4,615.92<br />

Average Rate – (Rs.) 7,089.85 5,688.50<br />

3. Furnace Oil<br />

Quantity (k. ltrs.) NIL NIL<br />

Total Amount - (Rs. million) NIL NIL<br />

Average Rate NIL NIL<br />

30<br />

31