S M I T H & N E P H E W<br />
UNIPOLAR SYSTEM<br />
R E F E R E N C E G U I D E
UNIPOLAR<br />
SYSTEM<br />
The Streamlined Choice<br />
For Superior Performance<br />
W<br />
ith the Smith & Nephew Unipolar<br />
System, joint restoration is achieved with<br />
surgical flexibility that benefits both the<br />
surgeon and the patient.<br />
The system uses two <strong>com</strong>ponents: a taper<br />
sleeve and a solid cobalt chromium head.<br />
This design simplifies implantation and<br />
eliminates concerns with polyethylene<br />
wear debris which may be present in<br />
other unipolar designs.<br />
Unipolar <strong>com</strong>ponents <strong>com</strong>e in a full range<br />
of sizes, from 40 to 55 mm in 1 mm increments,<br />
and 57, 59, and 61 mm. <strong>Taper</strong><br />
sleeves are used to adjust the neck length<br />
of the unipolar head. Five neck length<br />
options are available to fit Smith & Nephew<br />
<strong>12</strong>/<strong>14</strong> taper femoral <strong>com</strong>ponents and four<br />
neck length options are available to fit<br />
large taper femoral <strong>com</strong>ponents.<br />
The Unipolar System.<br />
From Smith & Nephew.
R E F E R E N C E<br />
1<br />
Acetabular Measurement<br />
Measure excised femoral head with<br />
ID/OD gauge or calipers. Acetabular<br />
measurement can be performed<br />
with a trial head and trial handle.<br />
2<br />
Trial Options<br />
<strong>12</strong>/<strong>14</strong> <strong>Taper</strong><br />
Large <strong>Taper</strong><br />
Trial Head<br />
Stem <strong>Taper</strong><br />
Neck Lengths<br />
Five trial sleeves available for <strong>12</strong>/<strong>14</strong> taper stems;<br />
four trial sleeves available for large taper stems.<br />
<strong>12</strong>/<strong>14</strong><br />
Large<br />
–3<br />
+0<br />
+0<br />
+4 +8 +<strong>12</strong><br />
+4 +8 +<strong>12</strong>
3<br />
Broach and<br />
Implant Trialing<br />
Follow the surgical technique<br />
for the specific femoral <strong>com</strong>ponent<br />
to be used. Neck length trialing<br />
can be ac<strong>com</strong>plished by using<br />
trial Unipolar sleeves and trial<br />
Unipolar heads. Trialing can<br />
be performed off either the<br />
broach or the implant.<br />
4<br />
Implant Assembly<br />
1. Clean and dry the stem taper.<br />
2. Place the appropriate length<br />
taper sleeve onto the stem<br />
taper.<br />
3. Impact the sleeve with the<br />
femoral head impactor and<br />
mallet.<br />
4. Clean and dry the taper sleeve<br />
and place the appropriate size<br />
Unipolar head onto the sleeve.<br />
5. Impact with the femoral head<br />
impactor and mallet.<br />
See package insert for important medical information.
C A T A L O G I N F O R M A T I O N<br />
UNIPOLAR HEADS<br />
CoCr Outside<br />
Implant Diameter Trial<br />
Cat. No. (mm) Cat. No.<br />
<strong>12</strong>-6640 40 11-7840<br />
<strong>12</strong>-6641 41 11-7841<br />
<strong>12</strong>-6642 42 11-7842<br />
<strong>12</strong>-6643 43 11-7843<br />
<strong>12</strong>-6644 44 11-7844<br />
<strong>12</strong>-6645 45 11-7845<br />
<strong>12</strong>-6646 46 11-7846<br />
<strong>12</strong>-6647 47 11-7847<br />
<strong>12</strong>-6648 48 11-7848<br />
<strong>12</strong>-6649 49 11-7849<br />
<strong>12</strong>-6650 50 11-7850<br />
<strong>12</strong>-6651 51 11-7851<br />
<strong>12</strong>-6652 52 11-7852<br />
<strong>12</strong>-6653 53 11-7853<br />
<strong>12</strong>-6654 54 11-7854<br />
<strong>12</strong>-6655 55 11-7855<br />
<strong>12</strong>-6657 57 11-7857<br />
<strong>12</strong>-6659 59 11-7859<br />
<strong>12</strong>-6661 61 11-7861<br />
UNIPOLAR<br />
<strong>12</strong>/<strong>14</strong> TAPER SLEEVES *<br />
Cat. No. Length Trials<br />
7132-6603 –3 mm 7136-6603<br />
7132-6600 +0 mm 7136-6600<br />
7132-6604 +4 mm 7136-6604<br />
7132-6608 +8 mm 7136-6608<br />
7132-66<strong>12</strong> +<strong>12</strong> mm 7136-66<strong>12</strong><br />
* For use with Smith & Nephew <strong>12</strong>/<strong>14</strong> taper femoral <strong>com</strong>ponents.<br />
UNIPOLAR<br />
LARGE TAPER SLEEVES **<br />
Cat. No. Length Trials<br />
<strong>12</strong>-6600 + 0 mm 11-7800<br />
<strong>12</strong>-6604 + 4 mm 11-7804<br />
<strong>12</strong>-6608 + 8 mm 11-7808<br />
<strong>12</strong>-66<strong>12</strong> +<strong>12</strong> mm 11-78<strong>12</strong><br />
**For use with MATRIX ® large taper stems, Spectron ® EF, and Cobra (<strong>14</strong>/16 taper).<br />
OR<br />
UNIPOLAR INSTRUMENT AND TRIAL TRAY<br />
11-7406<br />
Qty. Tray accepts one each of the following: Cat. No.<br />
1 Trial Handle 73-2119<br />
1 <strong>Taper</strong> Sleeve Removal Tool 11-6608<br />
1 - 3 mm <strong>12</strong>/<strong>14</strong> <strong>Taper</strong> Sleeve Trial 7136-6603<br />
1 + 0 mm <strong>12</strong>/<strong>14</strong> <strong>Taper</strong> Sleeve Trial 7136-6600<br />
1 + 4 mm <strong>12</strong>/<strong>14</strong> <strong>Taper</strong> Sleeve Trial 7136-6604<br />
1 + 8 mm <strong>12</strong>/<strong>14</strong> <strong>Taper</strong> Sleeve Trial 7136-6608<br />
1 +<strong>12</strong> mm <strong>12</strong>/<strong>14</strong> <strong>Taper</strong> Sleeve Trial 7136-66<strong>12</strong><br />
1 + 0 mm Large <strong>Taper</strong> Sleeve Trial 11-7800<br />
1 + 4 mm Large <strong>Taper</strong> Sleeve Trial 11-7804<br />
1 + 8 mm Large <strong>Taper</strong> Sleeve Trial 11-7808<br />
1 +<strong>12</strong> mm Large <strong>Taper</strong> Sleeve Trial 11-78<strong>12</strong><br />
1 40 mm Unipolar Trial Head 11-7840<br />
1 41 mm Unipolar Trial Head 11-7841<br />
1 42 mm Unipolar Trial Head 11-7842<br />
1 43 mm Unipolar Trial Head 11-7843<br />
1 44 mm Unipolar Trial Head 11-7844<br />
1 45 mm Unipolar Trial Head 11-7845<br />
1 46 mm Unipolar Trial Head 11-7846<br />
1 47 mm Unipolar Trial Head 11-7847<br />
1 48 mm Unipolar Trial Head 11-7848<br />
1 49 mm Unipolar Trial Head 11-7849<br />
1 50 mm Unipolar Trial Head 11-7850<br />
1 51 mm Unipolar Trial Head 11-7851<br />
1 52 mm Unipolar Trial Head 11-7852<br />
1 53 mm Unipolar Trial Head 11-7853<br />
1 54 mm Unipolar Trial Head 11-7854<br />
1 55 mm Unipolar Trial Head 11-7855<br />
1 57 mm Unipolar Trial Head 11-7857<br />
1 59 mm Unipolar Trial Head 11-7859<br />
1 61 mm Unipolar Trial Head 11-7861
All trademarks are the property of Smith & Nephew, Inc.<br />
11/97 7138-0327