Profiles for extruder downstream devices
Profiles for extruder downstream devices
Profiles for extruder downstream devices
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Profiles</strong> <strong>for</strong> <strong>extruder</strong> <strong>downstream</strong> <strong>devices</strong> – Part 2: Puller<br />
5.3 Second TPDO<br />
This TPDO shall be transmitted to the master-<strong>extruder</strong>. It contains by default the puller speed<br />
set echo, and the product speed.<br />
Table 6 specifies the object description of the PDO communication parameter and Table 7<br />
specifies the associated entry description. The values are defined in /CiA301/. The sub-index<br />
04 h is reserved <strong>for</strong> compatibility reasons and shall not be implemented.<br />
Table 6 — Object description<br />
Attribute<br />
Index<br />
Name<br />
Object code<br />
Data type<br />
Category<br />
Value<br />
1801 h<br />
TPDO 2 communication parameter<br />
Record<br />
PDO communication parameter record<br />
Mandatory<br />
Table 7 — Entry description<br />
Attribute<br />
Sub-index<br />
00 h<br />
Value<br />
Description<br />
Entry category<br />
Access<br />
PDO mapping<br />
Value range<br />
Default value<br />
Highest sub-index supported<br />
Mandatory<br />
const<br />
No<br />
02 h to 05 h<br />
Device-specific<br />
Sub-index<br />
Description<br />
Entry category<br />
Access<br />
PDO mapping<br />
Value range<br />
Default value<br />
01 h<br />
COB-ID<br />
Mandatory<br />
const<br />
No<br />
See /CiA301/<br />
4000 0280 h + node-ID<br />
Sub-index<br />
Description<br />
Entry category<br />
Access<br />
PDO mapping<br />
Value range<br />
Default value<br />
02 h<br />
Transmission type<br />
Mandatory<br />
rw<br />
Optional<br />
See /CiA301/<br />
01 h<br />
8 ! CiA 2007 – All rights reserved