<strong>ABS</strong> <strong>LIFTING</strong> <strong>STATION</strong> <strong>SANIMAT</strong> <strong>1000</strong> S-1<br />

Installation Example<br />

1<br />

Backwash loop with base<br />

above the backwash level<br />

1<br />

1<br />

Backwash level<br />

2<br />

3<br />

Attention to the backwash level is of<br />

vital importance for effective dewatering.<br />

A backwash occurs if the sewer lines<br />

are filled up completely due to heavy<br />

rainfall. In this case the lines used for<br />

the dewatering of buildings and sites<br />

are filled up to the backwash level. All<br />

outflow points located below the backwash<br />

level must be protected against<br />

back flow. According to standard (EN<br />

12056) the backwash level is determined<br />

by the local authorities. If no<br />

information is available then in the case<br />

of level ground the street surface at the<br />

connection point may be taken as the<br />

back-wash level. By street surface we<br />

mean the roadway including paths, hard<br />

shoulder, etc.<br />

Accessories<br />

Description (Materials) Size Part No.<br />

Discharge side<br />

1<br />

Hand membrane pump G 1½” 14990028<br />

with built-in non return valve for separate wall fixing<br />

2<br />

3<br />

4<br />

5<br />

Shut-off valve (EN-GJL-250) DN 80 61420500<br />

including 1 set of bolts and seal PN10<br />

Inflow side<br />

Inflow Adapter DN 100 41405002<br />

(1 supplied as standard)<br />

Flanged sleeve E-KS DN 100 62540025<br />

transition piece DIN-flange/push-on sleeve including 1 set of bolts<br />

and 1 flat gasket for vertical inflow<br />

Flanged spigot (EN-GJL-250) 4”/DN 100 41400594<br />

for horizontal inflow in conjunction with<br />

shut off valve<br />

Shut-off valve (EN-GJL-250) DN 100 61420501<br />

including 1 set of bolts and 1 flat gasket, flange PN 16<br />

Electrical accessories<br />

Plug in alarm 16020201<br />

NC-Battery for mains independant alarm 12820031<br />

(can be fitted into the standard control panel Sanimat <strong>1000</strong> S-1<br />

1<br />

4<br />

5<br />

4<br />

210061 <strong>GB</strong> 12.2006 <strong>ABS</strong> reserves the right to alter specifications due to technical developments.<br />