10.05.2015 Views

ABS LIFTING STATION SANIMAT 1000 S-1 (GB).indd

ABS LIFTING STATION SANIMAT 1000 S-1 (GB).indd

ABS LIFTING STATION SANIMAT 1000 S-1 (GB).indd

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ABS</strong> <strong>LIFTING</strong> <strong>STATION</strong><br />

<strong>SANIMAT</strong> <strong>1000</strong> S-1<br />

Faecal Lifting Station for the removal of wastewater<br />

and sewage from areas below sewer level. Ideal for<br />

effective dewatering of houses with one or two living<br />

units and for new buildings or renovation of old<br />

building.<br />

DIN/EN 12050-1<br />

Applications<br />

In the case of new buildings or when carrying out installations<br />

in cellars it is often the case that effluent from WCs, showers or<br />

baths cannot flow directly into the sewer due to the fact that the<br />

outlets are located below the backwash level. In these cases it is<br />

necessary to install a faecal lifting station (DIN/EN 12056).<br />

Medium pumped<br />

Clear water, wastewater, sewage and faecal effluent containing<br />

both solid and fibrous matter.<br />

Toilet-direct connection<br />

(180 mm EURO-WC, 220 mm Wall-WC).<br />

The collection tank may be located at floor level or sunken as<br />

circumstances require it. Further connections for wastewater<br />

sources from the side or from the top.<br />

Construction<br />

Synthetic tank<br />

Corrosion resistant, gas and odour-tight in accordance with<br />

DIN/EN 12050-1. Three main inlets DN 100, three additional<br />

connection ports DN 70, horizontal and vertical, plus one DN 40<br />

port connection for hand operated membrane pump G 1½” and<br />

vent line DN 70.<br />

Motor<br />

Three-phase versions 400 V3~ or single-phase version<br />

230 V~, 50 Hz, 2-Pole (2900 min -1 ), Insulation Class F, Protection<br />

Type IP 68.<br />

Bearings<br />

The rotor shaft is supported in maintenance-free lubricated-forlife<br />

ball-bearings.<br />

Shaft sealing<br />

Motor and medium side by means of a double lip seal.<br />

Discharge Connections<br />

Sleeve 4” (Diameter 110 mm bore) via DN80 flange.<br />

Contrablock system<br />

Consisting of a spiral bottom plate with waved inlet shearing<br />

edge and open <strong>ABS</strong> channel type impeller preventing blockage<br />

of the impeller where there is a high proportion of solid or<br />

fibrous matter present.<br />

Space-saving<br />

The fact that the discharge and vent lines are vertical means<br />

that it is possible to have a simple, economical installation.<br />

Control Unit<br />

Control unit, with automatic level control, and potential-free<br />

fault indication and alarm-horn (pre-equipped for mains<br />

independent alarm).<br />

Control Unit<br />

Control unit is mounted above flood level.<br />

Medium Temperature<br />

40° C, short term to 60° C (max. 5 min)<br />

Control unit with automatic level control,<br />

potential-free fault indication and alarm-horn<br />

Flexible connection into discharge line with<br />

flange DN 80 and sleeve 4”<br />

Robust corrosion resistant synthetic tank<br />

of compact design<br />

Easily transportable, can pass through<br />

a standard door opening<br />

Flood-proof <strong>ABS</strong> submersible pumps with<br />

Contrablock System<br />

Seven inlet ports, at different heights and a<br />

range of diameters, both horizontal and vertical<br />

Integrated non-return valve system<br />

No sump required<br />

Reduces installation cost<br />

Odour proof<br />

www.absgroup.com


D+W<br />

<strong>ABS</strong> <strong>LIFTING</strong> <strong>STATION</strong> <strong>SANIMAT</strong> <strong>1000</strong> S-1<br />

Technical Data<br />

Inlet Vent Discharge Motor Speed Rated Cable ‡ Weight **<br />

port port connection power* at 50 Hz voltage and length<br />

P 1<br />

P 2<br />

rated current<br />

DN DN DN DN kW kW min -1 V A m kg<br />

Sanimat <strong>1000</strong> S-1/W 100 (3 x) 70 (3 x) 70 Sleeve 4” DN 100 1.70 1.20 2900 220-240 ~ 5.7 4+1.5 50<br />

Sanimat <strong>1000</strong> S-1/D 100 (3 x) 70 (3 x) 70 Sleeve 4” DN 100 1.70 1.20 2900 400 3 ~ 3.3 4+1.5 50<br />

* P 1<br />

= Power taken from mains; P 2<br />

= Power at motor shaft ‡Tank Control Unit 4 m, Control Unit 1.5 m ** Additional weight of the hand membrane pump = 13 kg<br />

Supplied as Standard: Tank with pump, automatic level control, and control box, non-return valve, 4” sleeve and flange.<br />

Performance Curve 50 Hz<br />

H<br />

[m]<br />

8<br />

H = Total head<br />

Q = Discharge volume<br />

Curves to ISO 9906<br />

6<br />

4<br />

2<br />

Q<br />

(m³/h)<br />

Q<br />

[l/s]<br />

0<br />

0<br />

0<br />

5<br />

10 15 20<br />

2.5<br />

5.0<br />

25<br />

7.5<br />

Performance curve for 60 Hz is available on request.<br />

30<br />

35<br />

10<br />

Materials<br />

Tank________________________________________Polyethylene<br />

Motor housing _______________________Cast Iron EN-GJL-250<br />

Rotor Shaft _________________ Stainless Steel 1.4021 (AISI 420)<br />

Volute_______________________________________Polyethylene<br />

Impeller ____________________________Cast Iron EN-GJL-250


<strong>ABS</strong> <strong>LIFTING</strong> <strong>STATION</strong> <strong>SANIMAT</strong> <strong>1000</strong> S-1<br />

Dimensions<br />

mm<br />

Discharge Sleeve 4”<br />

with flexible connection<br />

Flange DN 80, PN 10<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

Connections<br />

DN 100 INFLOW<br />

DN 100 INFLOW<br />

DN 100 INFLOW<br />

DN 70 INFLOW<br />

DN 70 INFLOW<br />

DN 70 VENT or INFLOW<br />

DN 70 VENT or INFLOW<br />

DN 40 INFLOW or HANDMEMBRANE PUMP<br />

DN 40 LEVEL CONTROL<br />

SLEEVE 4” DISCHARGE LINE<br />

Rooms for sewage lifting stations must be large enough<br />

that a working area of at least 0.6 m width and height is<br />

available around all parts which have to be operated or<br />

maintained. A pump sump should be provided for dewatering<br />

of the room itself.


<strong>ABS</strong> <strong>LIFTING</strong> <strong>STATION</strong> <strong>SANIMAT</strong> <strong>1000</strong> S-1<br />

Installation Example<br />

1<br />

Backwash loop with base<br />

above the backwash level<br />

1<br />

1<br />

Backwash level<br />

2<br />

3<br />

Attention to the backwash level is of<br />

vital importance for effective dewatering.<br />

A backwash occurs if the sewer lines<br />

are filled up completely due to heavy<br />

rainfall. In this case the lines used for<br />

the dewatering of buildings and sites<br />

are filled up to the backwash level. All<br />

outflow points located below the backwash<br />

level must be protected against<br />

back flow. According to standard (EN<br />

12056) the backwash level is determined<br />

by the local authorities. If no<br />

information is available then in the case<br />

of level ground the street surface at the<br />

connection point may be taken as the<br />

back-wash level. By street surface we<br />

mean the roadway including paths, hard<br />

shoulder, etc.<br />

Accessories<br />

Description (Materials) Size Part No.<br />

Discharge side<br />

1<br />

Hand membrane pump G 1½” 14990028<br />

with built-in non return valve for separate wall fixing<br />

2<br />

3<br />

4<br />

5<br />

Shut-off valve (EN-GJL-250) DN 80 61420500<br />

including 1 set of bolts and seal PN10<br />

Inflow side<br />

Inflow Adapter DN 100 41405002<br />

(1 supplied as standard)<br />

Flanged sleeve E-KS DN 100 62540025<br />

transition piece DIN-flange/push-on sleeve including 1 set of bolts<br />

and 1 flat gasket for vertical inflow<br />

Flanged spigot (EN-GJL-250) 4”/DN 100 41400594<br />

for horizontal inflow in conjunction with<br />

shut off valve<br />

Shut-off valve (EN-GJL-250) DN 100 61420501<br />

including 1 set of bolts and 1 flat gasket, flange PN 16<br />

Electrical accessories<br />

Plug in alarm 16020201<br />

NC-Battery for mains independant alarm 12820031<br />

(can be fitted into the standard control panel Sanimat <strong>1000</strong> S-1<br />

1<br />

4<br />

5<br />

4<br />

210061 <strong>GB</strong> 12.2006 <strong>ABS</strong> reserves the right to alter specifications due to technical developments.<br />

| <strong>ABS</strong> Group | Tel. +46 40 35 04 70 | Fax +46 40 35 50 45 | info@absgroup.com | www.absgroup.com |

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!