ABS LIFTING STATION SANIMAT 1000 S-1 (GB).indd
ABS LIFTING STATION SANIMAT 1000 S-1 (GB).indd
ABS LIFTING STATION SANIMAT 1000 S-1 (GB).indd
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>ABS</strong> <strong>LIFTING</strong> <strong>STATION</strong><br />
<strong>SANIMAT</strong> <strong>1000</strong> S-1<br />
Faecal Lifting Station for the removal of wastewater<br />
and sewage from areas below sewer level. Ideal for<br />
effective dewatering of houses with one or two living<br />
units and for new buildings or renovation of old<br />
building.<br />
DIN/EN 12050-1<br />
Applications<br />
In the case of new buildings or when carrying out installations<br />
in cellars it is often the case that effluent from WCs, showers or<br />
baths cannot flow directly into the sewer due to the fact that the<br />
outlets are located below the backwash level. In these cases it is<br />
necessary to install a faecal lifting station (DIN/EN 12056).<br />
Medium pumped<br />
Clear water, wastewater, sewage and faecal effluent containing<br />
both solid and fibrous matter.<br />
Toilet-direct connection<br />
(180 mm EURO-WC, 220 mm Wall-WC).<br />
The collection tank may be located at floor level or sunken as<br />
circumstances require it. Further connections for wastewater<br />
sources from the side or from the top.<br />
Construction<br />
Synthetic tank<br />
Corrosion resistant, gas and odour-tight in accordance with<br />
DIN/EN 12050-1. Three main inlets DN 100, three additional<br />
connection ports DN 70, horizontal and vertical, plus one DN 40<br />
port connection for hand operated membrane pump G 1½” and<br />
vent line DN 70.<br />
Motor<br />
Three-phase versions 400 V3~ or single-phase version<br />
230 V~, 50 Hz, 2-Pole (2900 min -1 ), Insulation Class F, Protection<br />
Type IP 68.<br />
Bearings<br />
The rotor shaft is supported in maintenance-free lubricated-forlife<br />
ball-bearings.<br />
Shaft sealing<br />
Motor and medium side by means of a double lip seal.<br />
Discharge Connections<br />
Sleeve 4” (Diameter 110 mm bore) via DN80 flange.<br />
Contrablock system<br />
Consisting of a spiral bottom plate with waved inlet shearing<br />
edge and open <strong>ABS</strong> channel type impeller preventing blockage<br />
of the impeller where there is a high proportion of solid or<br />
fibrous matter present.<br />
Space-saving<br />
The fact that the discharge and vent lines are vertical means<br />
that it is possible to have a simple, economical installation.<br />
Control Unit<br />
Control unit, with automatic level control, and potential-free<br />
fault indication and alarm-horn (pre-equipped for mains<br />
independent alarm).<br />
Control Unit<br />
Control unit is mounted above flood level.<br />
Medium Temperature<br />
40° C, short term to 60° C (max. 5 min)<br />
Control unit with automatic level control,<br />
potential-free fault indication and alarm-horn<br />
Flexible connection into discharge line with<br />
flange DN 80 and sleeve 4”<br />
Robust corrosion resistant synthetic tank<br />
of compact design<br />
Easily transportable, can pass through<br />
a standard door opening<br />
Flood-proof <strong>ABS</strong> submersible pumps with<br />
Contrablock System<br />
Seven inlet ports, at different heights and a<br />
range of diameters, both horizontal and vertical<br />
Integrated non-return valve system<br />
No sump required<br />
Reduces installation cost<br />
Odour proof<br />
www.absgroup.com
D+W<br />
<strong>ABS</strong> <strong>LIFTING</strong> <strong>STATION</strong> <strong>SANIMAT</strong> <strong>1000</strong> S-1<br />
Technical Data<br />
Inlet Vent Discharge Motor Speed Rated Cable ‡ Weight **<br />
port port connection power* at 50 Hz voltage and length<br />
P 1<br />
P 2<br />
rated current<br />
DN DN DN DN kW kW min -1 V A m kg<br />
Sanimat <strong>1000</strong> S-1/W 100 (3 x) 70 (3 x) 70 Sleeve 4” DN 100 1.70 1.20 2900 220-240 ~ 5.7 4+1.5 50<br />
Sanimat <strong>1000</strong> S-1/D 100 (3 x) 70 (3 x) 70 Sleeve 4” DN 100 1.70 1.20 2900 400 3 ~ 3.3 4+1.5 50<br />
* P 1<br />
= Power taken from mains; P 2<br />
= Power at motor shaft ‡Tank Control Unit 4 m, Control Unit 1.5 m ** Additional weight of the hand membrane pump = 13 kg<br />
Supplied as Standard: Tank with pump, automatic level control, and control box, non-return valve, 4” sleeve and flange.<br />
Performance Curve 50 Hz<br />
H<br />
[m]<br />
8<br />
H = Total head<br />
Q = Discharge volume<br />
Curves to ISO 9906<br />
6<br />
4<br />
2<br />
Q<br />
(m³/h)<br />
Q<br />
[l/s]<br />
0<br />
0<br />
0<br />
5<br />
10 15 20<br />
2.5<br />
5.0<br />
25<br />
7.5<br />
Performance curve for 60 Hz is available on request.<br />
30<br />
35<br />
10<br />
Materials<br />
Tank________________________________________Polyethylene<br />
Motor housing _______________________Cast Iron EN-GJL-250<br />
Rotor Shaft _________________ Stainless Steel 1.4021 (AISI 420)<br />
Volute_______________________________________Polyethylene<br />
Impeller ____________________________Cast Iron EN-GJL-250
<strong>ABS</strong> <strong>LIFTING</strong> <strong>STATION</strong> <strong>SANIMAT</strong> <strong>1000</strong> S-1<br />
Dimensions<br />
mm<br />
Discharge Sleeve 4”<br />
with flexible connection<br />
Flange DN 80, PN 10<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
Connections<br />
DN 100 INFLOW<br />
DN 100 INFLOW<br />
DN 100 INFLOW<br />
DN 70 INFLOW<br />
DN 70 INFLOW<br />
DN 70 VENT or INFLOW<br />
DN 70 VENT or INFLOW<br />
DN 40 INFLOW or HANDMEMBRANE PUMP<br />
DN 40 LEVEL CONTROL<br />
SLEEVE 4” DISCHARGE LINE<br />
Rooms for sewage lifting stations must be large enough<br />
that a working area of at least 0.6 m width and height is<br />
available around all parts which have to be operated or<br />
maintained. A pump sump should be provided for dewatering<br />
of the room itself.
<strong>ABS</strong> <strong>LIFTING</strong> <strong>STATION</strong> <strong>SANIMAT</strong> <strong>1000</strong> S-1<br />
Installation Example<br />
1<br />
Backwash loop with base<br />
above the backwash level<br />
1<br />
1<br />
Backwash level<br />
2<br />
3<br />
Attention to the backwash level is of<br />
vital importance for effective dewatering.<br />
A backwash occurs if the sewer lines<br />
are filled up completely due to heavy<br />
rainfall. In this case the lines used for<br />
the dewatering of buildings and sites<br />
are filled up to the backwash level. All<br />
outflow points located below the backwash<br />
level must be protected against<br />
back flow. According to standard (EN<br />
12056) the backwash level is determined<br />
by the local authorities. If no<br />
information is available then in the case<br />
of level ground the street surface at the<br />
connection point may be taken as the<br />
back-wash level. By street surface we<br />
mean the roadway including paths, hard<br />
shoulder, etc.<br />
Accessories<br />
Description (Materials) Size Part No.<br />
Discharge side<br />
1<br />
Hand membrane pump G 1½” 14990028<br />
with built-in non return valve for separate wall fixing<br />
2<br />
3<br />
4<br />
5<br />
Shut-off valve (EN-GJL-250) DN 80 61420500<br />
including 1 set of bolts and seal PN10<br />
Inflow side<br />
Inflow Adapter DN 100 41405002<br />
(1 supplied as standard)<br />
Flanged sleeve E-KS DN 100 62540025<br />
transition piece DIN-flange/push-on sleeve including 1 set of bolts<br />
and 1 flat gasket for vertical inflow<br />
Flanged spigot (EN-GJL-250) 4”/DN 100 41400594<br />
for horizontal inflow in conjunction with<br />
shut off valve<br />
Shut-off valve (EN-GJL-250) DN 100 61420501<br />
including 1 set of bolts and 1 flat gasket, flange PN 16<br />
Electrical accessories<br />
Plug in alarm 16020201<br />
NC-Battery for mains independant alarm 12820031<br />
(can be fitted into the standard control panel Sanimat <strong>1000</strong> S-1<br />
1<br />
4<br />
5<br />
4<br />
210061 <strong>GB</strong> 12.2006 <strong>ABS</strong> reserves the right to alter specifications due to technical developments.<br />
| <strong>ABS</strong> Group | Tel. +46 40 35 04 70 | Fax +46 40 35 50 45 | info@absgroup.com | www.absgroup.com |