Service & Installation - Gas Equipment Company, Inc.
Service & Installation - Gas Equipment Company, Inc.
Service & Installation - Gas Equipment Company, Inc.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Gas</strong> Detection Devices<br />
Sensit ® CO<br />
Carbon Monoxide Analyzer<br />
A portable, state-of-the-art carbon monoxide analyzer designed to determine the level of CO in residential and commercial environments from<br />
0 to 2000ppm.<br />
Unlike traditional CO analyzers, the SENSIT CO utilizes a rotary vane pump to draw in the correct amount of sample air to analyze. This<br />
method provides a sensor accuracy of ± 5ppm or ± 5% of the reading, whichever is greater.<br />
Specifications<br />
Operational<br />
Temp.<br />
Duty<br />
Cycle<br />
Detection Range<br />
Resolution<br />
Response<br />
Time<br />
Sensor<br />
Accuracy<br />
Power Source<br />
0-104˚F<br />
Auto shut off<br />
after 30 minutes<br />
0-1999 ppm 1 ppm<br />
3 seconds, 90% of reading<br />
in less than 60 seconds<br />
±5 ppm, ±5% of reading,<br />
whichever is greater<br />
3 "C" alkaline<br />
batteries<br />
Physical<br />
Size<br />
Weight<br />
Construction<br />
Battery<br />
Life<br />
Sensor<br />
3" x 10"<br />
x 2.4"<br />
1.1 lb. Durable ABS plastic<br />
20+ hrs.<br />
continuous<br />
operation<br />
Long life<br />
electrochemical<br />
Product Information<br />
• 3 year warranty (excluding<br />
calibration and batteries)<br />
• Sensor warranty for 2 years<br />
• Hard carrying case • Flue probe<br />
• 5 ft. of flexible tubing<br />
• Particle filter • Batteries included<br />
• Instrument manual<br />
Water/Particle<br />
Filter<br />
On/Off<br />
Button<br />
JN-SSCO0500-SN<br />
Bright Backlit<br />
Display<br />
Zero<br />
Button<br />
Back Light<br />
Button<br />
Hot Air<br />
Probe<br />
Battery<br />
Compartment<br />
Symptoms of Carbon Monoxide Exposure<br />
Level (PPM)<br />
Effects*<br />
0 Desirable level<br />
9 Acceptable level in living space<br />
50 Maximum concentration for continuous<br />
exposure in any 8 hour period<br />
400 Frontal headaches in 1 to 2 hours, life<br />
threatening after 3 hours<br />
800 Nausea and convulsions, death within 2 hours<br />
1,600 Nausea within 20 minutes, death within 1 hour<br />
12,800 Death within 1 to 3 minutes<br />
*Effects vary based on age, sex, weight and overall health<br />
252