Compressor Selection Guide<br />

Propane Vapor Recovery<br />

Assuming<br />

• 33,000 water gallon capacity (124,915 lts.) tank car.<br />

• Blackmer LB-361 <strong>Gas</strong> Compressor, 36 CFM Piston Displacement.<br />

• The chart indicates the volume of recoverable liquid and<br />

recovery time required at various pressures.<br />

Beginning<br />

Tank<br />

Pressure<br />

PSIG<br />

Total Product*<br />

(In Vapor Form)<br />

Gallons<br />

Liters<br />

Economically<br />

Recoverable<br />

Product**<br />

Gallons<br />

Liters<br />

200<br />

1,650<br />

6,246<br />

1,153<br />

4,365<br />

175<br />

1,485<br />

5,621<br />

969<br />

3,668<br />

150<br />

1,315<br />

4,978<br />

845<br />

3,199<br />

125<br />

1,137<br />

4,304<br />

713<br />

22,699<br />

100<br />

95.<br />

3 3,607<br />

580<br />

2,196<br />

75<br />

760<br />

2,877<br />

441<br />

1,669<br />

50<br />

561<br />

2,124<br />

419<br />

1,586<br />

Tank car vapor recovery system<br />

If, for example, after the liquid transfer phase of the unloading<br />

operation is complete, the vapor pressure reads 150 psig,<br />

there would be approximately 1315 gallons of LP <strong>Gas</strong> in vapor<br />

form remaining in the tank car. Of this, 845 gallons can be<br />

economically recovered in less than three hours.<br />

* Physical properties based on NFPA #58 data for commercial propane.<br />

** Economically recoverable product based on reduction of tank pressure to<br />

25% of original value. Residual liquid not included.<br />

Corken <strong>Compressors</strong><br />

A compressor unit for liquid transfer and<br />

residual vapor recovery of volatile liquids.<br />

Part No.<br />

NOTE: Motors sold separately.<br />

Capacity<br />

291-107 88 GPM<br />

491-107 198 GPM<br />

691-107 330 GPM<br />

D891-107B<br />

550 GPM<br />

SPECIFY MOTOR HORSE POWER TO BE USED.<br />

LP-<strong>Gas</strong> <strong>Compressors</strong> – Sized for Liquid Transfer and Vapor Recovery<br />

Compressor<br />

Model<br />

Comp<br />

RPM<br />

GPM<br />

Capacity<br />

CFH<br />

Horse<br />

Power<br />

Phase<br />

Frame<br />

Size<br />

Suggested Pipe Size<br />

Hose Size<br />

NOTE: The capacity shown will vary depending on the length and size of piping and hoses. If piping is complex or over 100’ in length, use the next larger pipe size.<br />

Inlet<br />

Vapor<br />

Liquid<br />

Vapor<br />

290-107-1<br />

695<br />

77<br />

14<br />

5 3 184T<br />

2"<br />

1 1 /4" 1 1 /2" 1 1 /4"<br />

290-107-2<br />

695<br />

77<br />

14<br />

5 1 215T<br />

2"<br />

1 1 /4" 1 1 /2" 1 1 /4"<br />

290-107-3<br />

780<br />

88<br />

16<br />

7 1 /2 3 213T<br />

2 1 /2" 1 1 /4" 1 1 /2" 1 1 /4"<br />

490-107<br />

325<br />

77<br />

14<br />

5 3 184T<br />

2"<br />

1 1 /4" 1 1 /2" 1 1 /4"<br />

490-107<br />

446<br />

110<br />

20<br />

5 1 215T<br />

3"<br />

1 1 /2" 1 1 /2" 1 1 /4"<br />

490-107-1<br />

603<br />

148<br />

27<br />

7 1 /2 3 213T<br />

3"<br />

1 1 /2" 2"<br />

1 1 /2"<br />

490-107-2<br />

825<br />

198<br />

36<br />

10<br />

3 215T<br />

3"<br />

1 1 /2" 2 " 2"<br />

690-107<br />

403<br />

132<br />

24<br />

10<br />

3 215T<br />

3"<br />

1 1 /2" 2"<br />

1 1 /2"<br />

690-107<br />

493<br />

198<br />

36<br />

15<br />

3 254T<br />

3"<br />

1 1 /2" 2 " 2"<br />

690-107<br />

690<br />

275<br />

48<br />

20<br />

3 256T<br />

4 " 2 " 2 " 2"<br />

690-107<br />

822<br />

330<br />

60<br />

25<br />

3 284T<br />

4 " to 6"<br />

3 " 2 " 2"<br />