Shell Bitumen - WAM Field Test Results Italy - Inspiring Solutions for ...
Shell Bitumen - WAM Field Test Results Italy - Inspiring Solutions for ...
Shell Bitumen - WAM Field Test Results Italy - Inspiring Solutions for ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Picture 1 Emission samplers in the asphalt plant<br />
2.2 Conditions and measurements at the asphalt plant<br />
On 26 October, paving work involved the construction of a structural layer using<br />
Greenfalt. An amount of 870 tons of Greenfalt were laid on the site with a length of<br />
1300 m, 3.5 m width and thicknesses were 90, 50 and 90 mm <strong>for</strong> the three sections<br />
of this layer.<br />
Recorded air temperatures were 19°C in the morning and 30°C at 3 pm in the<br />
afternoon. Weather condition was cloudy with no wind. Paving crew sampling<br />
duration was around 400 minutes.<br />
Sampling <strong>for</strong> exposure measurements was per<strong>for</strong>med <strong>for</strong> the following jobs:<br />
A paver driver<br />
Two screedmen<br />
A skilled labourer / raker<br />
A roller compactor driver<br />
Personal pumps were used <strong>for</strong> fume sampling with a 2 l/min flow rate. The matter<br />
was collected on PTFE filters (2 µm) placed in the standard 37-mm cassette (see<br />
pictures 2 and 3):<br />
<br />
<br />
Total aerosols, which represents the mineral and organic aerosols<br />
BSF extracted from the filter with benzene, which represents the total organic<br />
aerosols (the remaining part is regarded as the mineral fraction or MF)<br />
3/11