03.06.2015 Views

EverSmart Jazz Scanners - Kodak

EverSmart Jazz Scanners - Kodak

EverSmart Jazz Scanners - Kodak

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Networking<br />

Networking<br />

Parallel Parallel processing<br />

Computer to plate to plate<br />

<strong>EverSmart</strong><br />

Reliable Reliable<br />

<strong>Jazz</strong><br />

proofing proofing<br />

<strong>Scanners</strong> Parallel Parallel proc pro<br />

Stochastic screening screening<br />

Workflow<br />

Digital Digital printing<br />

Stochastic screening<br />

Installation & Maintenance<br />

Mac and PC Platforms<br />

Stochastic screening<br />

High volume film out<br />

High volume film out<br />

Plate Plate ready read<br />

English<br />

Version Imposition<br />

Catalog No.<br />

399Z52780B


<strong>EverSmart</strong> <strong>Jazz</strong> <strong>Scanners</strong> Installation and Maintenance - Mac and PC Platforms<br />

i<br />

Important Notice<br />

document is delivered subject to the following conditions and restrictions:<br />

This<br />

This document contains proprietary information of CreoScitex.<br />

Such information is hereby supplied solely for the purpose of assisting authorized users of<br />

CreoScitex products.<br />

Without the express prior written permission of CreoScitex, no part of the contents hereof may be<br />

used for any other purposes, disclosed to any person or firm, or reproduced by any means.<br />

The text and drawings herein are for the purposes of illustration and reference only. The<br />

specifications on which they are based are subject to change without notice.<br />

Catalog No. 399Z52780B<br />

Copyright © 1999 by<br />

CreoScitex Corporation Ltd.<br />

All Rights Reserved<br />

First Edition June 1999<br />

Second Edition May 2000


ii<br />

Important Notice<br />

Trademarks<br />

CreoScitex and the CreoScitex logo are trademarks of CreoProducts Inc.<br />

PostScript® and Adobe PhotoShop® are trademarks of Adobe Systems, Incorporated, are registered<br />

in the U.S. Patent and Trademark Office and may be registered in other jurisdictions, as well.<br />

QuarkXPress is a registered patent and trademark of Quark, Inc.<br />

Apple and Macintosh are registered trademarks of Apple Computer, Inc.<br />

Windows and Windows NT are either registered trademarks or trademarks of Microsoft Corporation<br />

in the United States and/or other countries.<br />

Other company and brand, product and service names are for identification purposes only and may<br />

be trademarks or registered trademarks of their respective holders. Data subject to change without<br />

notice.<br />

US Patents<br />

This product is covered by one or more of the following US patents:<br />

4.350.996 4.456.924 4.500.919 4.834.520 4.853.709 5.079.721 5.103.407 5.111.308 5.113.249<br />

5.119.440 5.122.871 5.124.547 5.150.225 5.153.769 5.155.782 5.157.516 5.200.816 5.208.888<br />

5.221.997 5.227.895 5.247.174 5.247.352 5.296.935 5.299.020 5.313.278 5.323.248 5.325.217<br />

5.328.032 5.331.439 5.333.064 5.339.176 5.343.059 5.355.446 5.359.458 5.367.388 5.384.648<br />

5.384.899 5.412.491 5.412.737 5.420.702 5.473.733 5.481.379 5.488.906 5.497.252 5.508.828<br />

5.509.561 5.519.792 5.519.852 5.526.107 5.526.143 5.532.728 5.561.691 5.568.595 5.576.754<br />

5.579.115 5.592.309 5.594.556 5.600.448 5.608.822 5.615.282 5.623.001 5.636.330 5.649.220<br />

5.650.076 5.652.804 5.691.823 5.691.828 5.696.393 5.699.174 5.708.736 5.739.819 5.742.743<br />

5.764.381 5.771.794 5.785.309 5.813.346 5.861.904 5.875.288 5.894.342 5.900.981 5.934.196<br />

5.940.099 5.942.137 5.946.426


<strong>EverSmart</strong> <strong>Jazz</strong> <strong>Scanners</strong> Installation and Maintenance - Mac and PC Platforms<br />

iii<br />

Table of Contents<br />

About This Document<br />

vii<br />

Chapter 1 Site Preparation 1<br />

1.1 General Requirements ..........................................................2<br />

1.2 SafetyInstructions..............................................................6<br />

Chapter 2 Unpacking 7<br />

2.1 Unpacking the Scanner ..........................................................8<br />

2.1.1 Installation Kit (required for installation). .....................................12<br />

2.1.2 Included Kits (not required for installation). ...................................13<br />

2.2 UnlockingScrewsandRemovingPacking ..........................................14<br />

Chapter 3 Powering On 17<br />

3.1 Powering on the Scanner .......................................................18<br />

3.2 Startup Sequence .............................................................20<br />

3.3 Startup Troubleshooting ........................................................21<br />

Chapter 4 Software Installation 23<br />

4.1 Installation Procedure - Macintosh Computers . ......................................24<br />

4.2 Installation Procedure - Windows Operating System ..................................29<br />

Chapter 5 SCSI Configuration 35<br />

5.1 ConfigurationOptions..........................................................37<br />

5.2 SCSI Board Installation (if required) ...............................................41<br />

5.3 Connecting Options ............................................................45<br />

5.4 SCSIDriverInstallation.........................................................48<br />

5.5 SettingtheSCSIID............................................................49<br />

Chapter 6 Installation Program 51<br />

6.1 Stage 1: Launch the Installation & Utilities Application .................................52<br />

6.2 Stage 2: Begin the Installation Procedure ...........................................53<br />

6.3 Stage3:EntertheSerialNumber.................................................54<br />

6.4 Stage 4: Prepare the Scanner ....................................................57<br />

6.5 Stage 5: Automatic Diagnostics Check .............................................59<br />

6.6 Stage6:AutomaticOpticsCheck.................................................60


iv<br />

Table of Contents<br />

6.7 Stage7:CreateTables......................................................... 61<br />

6.8 Stage8:BackuptoDisketteorExternalMedia ...................................... 62<br />

6.9 Stage9:QuitInstallation........................................................ 64<br />

6.10 Troubleshooting for the Installation & Utilities Program ................................ 65<br />

Chapter 7 Utilities 73<br />

7.1 StatusScreen................................................................ 75<br />

7.2 CustomInstall................................................................ 76<br />

7.3 Scanner Checks .............................................................. 78<br />

7.4 CreateTables................................................................ 80<br />

7.5 BackupMedia................................................................ 82<br />

7.6 <strong>EverSmart</strong>ScanLogFolder-MacintoshComputers.................................. 84<br />

7.7 Log Folders - Windows Operating System .......................................... 85<br />

7.8 Diagnostics - Windows Operating System .......................................... 87<br />

7.8.1 System Requirements ................................................... 87<br />

7.8.2 InstallingInternetExplorer4.0.1........................................... 87<br />

7.8.3 Running the Diagnostic Application. ........................................ 88<br />

Chapter 8 Maintenance 91<br />

8.1 LampReplacement............................................................ 92<br />

8.1.1 ReplacingtheTransparencyLamp ........................................ 93<br />

8.1.2 ReplacingtheReflectiveLamps........................................... 98<br />

8.2 Cleaning the Glass ........................................................... 104<br />

8.2.1 Upper Glass Cleaning .................................................. 105<br />

8.2.2 Base Glass Cleaning. .................................................. 108<br />

Chapter 9 General Troubleshooting 111<br />

9.1 Power&Self-Tests........................................................... 113<br />

9.2 Scanning Quality. ............................................................ 115<br />

9.3 Scanner/Application Hangs. .................................................... 116<br />

9.4 lIluminationProblems......................................................... 117<br />

9.5 General SCSI Communication Problems .......................................... 117<br />

9.6 SCSI Communication Problems - Windows NT 4.0 .................................. 119<br />

Appendix A Packing the Scanner 127<br />

A.1 Locking the Scanner .......................................................... 128<br />

A.2 Packing the Scanner ......................................................... 131<br />

Appendix B Technical Specifications 135


<strong>EverSmart</strong> <strong>Jazz</strong> <strong>Scanners</strong> Installation and Maintenance - Mac and PC Platforms<br />

v<br />

Appendix C Documentation Folder 139<br />

C.1 MacDocumentationFolder.....................................................140<br />

C.2 Windows Documentation Folder .................................................145<br />

Appendix D Application Log Files 149<br />

D.1 MacintoshApplicationLogFiles .................................................150<br />

D.2 Windows Application Log Files ..................................................151<br />

Appendix E Catalog Numbers 153<br />

Index 157


<strong>EverSmart</strong> <strong>Jazz</strong> <strong>Scanners</strong> Installation and Maintenance - Mac and PC Platforms<br />

vii<br />

About This Document<br />

This guide provides detailed instructions about how to install the scanner properly, and maintain it in<br />

good operational condition.<br />

Chapter Breakdown<br />

The chapters are divided into installation chapters (one to six), and chapters that describe<br />

maintenance procedures and provide additional scanner information (seven to nine, and the<br />

appendixes).<br />

Installation<br />

Chapter 1, Site Preparation<br />

Chapter 2, Unpacking<br />

Chapter 3, Powering On<br />

Chapter 4, Software Installation<br />

Chapter 5, SCSI Configuration<br />

Chapter 6, Installation Program<br />

Specifies how to prepare the room in which the scanner will<br />

be located, and the hardware requirements.<br />

Explains how you open the scanner package, and lists the<br />

items you will see in the package.<br />

Explains the power-on and startup procedures.<br />

Explains how to install the application software.<br />

Describes how to connect the scanner to the system and how<br />

to set the SCSI ID.<br />

Explains how to use the Installation & Utilities program that<br />

will check and create tables for the scanner.<br />

Maintenance and Additional Scanner Information<br />

Chapter 7,Utilities<br />

Chapter 8, Maintenance<br />

Chapter 9, General<br />

Troubleshooting<br />

Appendix A, Packing the Scanner<br />

Describes the installation program utilities, and the log folder,<br />

which contains files that include scanner status information.<br />

Explains how to maintain your scanner, including lamp<br />

replacement and glass cleaning.<br />

Suggests ways to solve problems you may come across in your<br />

day-to-day work.<br />

Instructions on how to pack the scanner for transportation<br />

purposes.


viii<br />

About This Document<br />

Appendix B, Technical<br />

Technical specifications.<br />

Specifications<br />

Appendix C, Documentation folder Instructions on how to use the documentation located on the<br />

application CD-ROM.<br />

Appendix D, Application Log Files Instructions on now to create application log files.<br />

Appendix E, Catalog Numbers Catalog numbers of the parts.


<strong>EverSmart</strong> <strong>Jazz</strong> <strong>Scanners</strong> Installation and Maintenance - Mac and PC Platforms<br />

ix<br />

Document Convention<br />

The following conventions are used throughout this document:<br />

Item Purpose Example<br />

User interface<br />

elements<br />

Software buttons,<br />

menus and options<br />

Windows and field names, and other<br />

user interface elements are printed in<br />

italics.<br />

Named functions which you activate<br />

through the software are printed in bold.<br />

Open the Database Objects window.<br />

Click the Expand icon in the top<br />

right-hand corner.<br />

List item Bullet precedes a list item. • On-line<br />

• Off-line<br />

• Maintenance<br />

Action<br />

References<br />

Note<br />

Caution<br />

Tip<br />

Arrow indicates an action to be<br />

performed by you.<br />

The Book icon precedes reference to<br />

another book or to another place in the<br />

book.<br />

The Note icon precedes additional<br />

information.<br />

The Caution icon precedes a caution<br />

message.<br />

The Idea icon precedes a tip.<br />

Ø<br />

<br />

Select Remote Station and<br />

press Enter.<br />

Refer to the Site Preparation<br />

chapter.<br />

If too much film sticks out, cut the<br />

excessive part.<br />

Installation must be done by<br />

authorized service personnel only.<br />

If you wish Half resolution, set the<br />

Half Res field.<br />

Warning<br />

The Warning icon precedes a warning<br />

message.<br />

Danger of explosion if battery is<br />

incorrectly replaced!


x<br />

About This Document<br />

Item Purpose Example<br />

Emphasized text<br />

MAC<br />

Words or terms that are important in the<br />

context are printed either in bold or in<br />

italics.<br />

This icon at the upper right corner<br />

indicates instructions for MAC users.<br />

As a general user, you are able to<br />

search for Files and Folders.<br />

PC<br />

This icon at the upper right corner<br />

indicates instructions for PC users.<br />

Macintosh/Windows Conventions<br />

Macintosh/Windows operating conventions are followed in this guide. We assume that you have a<br />

working knowledge of mouse operation, and of standard Macintosh/Windows menus, commands,<br />

and dialog boxes. If necessary, you should refer to the Macintosh/Windows documentation for a<br />

review of the techniques.


1<br />

Chapter 1<br />

Site Preparation<br />

General Requirements ..........................2<br />

SafetyInstructions..............................6


2 Chapter 1 Site Preparation<br />

1.1 General Requirements<br />

This chapter describes the conditions that are necessary for proper<br />

<strong>EverSmart</strong> <strong>Jazz</strong> site preparation.<br />

Site<br />

Place the shipping package as close as possible to its final location.<br />

Before unpacking and installing the scanner, make sure the unpacking<br />

site is large enough to allow easy maneuvering.<br />

The scanner operates dependably in a standard, air-conditioned,<br />

business environment.<br />

Electrical<br />

Temperature Range:<br />

16°-27°C / 61°-81°F<br />

Humidity: 40% - 70%<br />

Input Voltage:<br />

Power Consumption:<br />

100-120/200-240 VAC<br />

Scanning Mode: 290W<br />

Standby: 200W<br />

Grounded, three-pronged, electric plug suited to local electricity<br />

requirements.<br />

Scanner Dimensions<br />

Supporting Table<br />

Height:<br />

Width:<br />

Depth:<br />

36 cm / 14 in.<br />

87 cm / 34.2 in.<br />

62 cm / 24.4 in.<br />

Ability to support 70 kg / 156 lb


General Requirements 3<br />

SCSI Cables<br />

Location within Structure<br />

The scanner should be placed within two meters of the computer, if<br />

you use the SCSI cable supplied with the scanner. You can locate the<br />

scanner up to six meters from the computer if you use longer cables.<br />

The scanner should be placed no less than 10 centimeters from a wall<br />

or other solid structure, on its right and rear sides. The distance<br />

between the left side from the structure should be no less than 20<br />

centimeters, to enable convenient scanner switch operation. The proper<br />

distances are shown in the following illustration:<br />

10 cm<br />

20 cm<br />

10 cm<br />

Scanner


MAC<br />

4 Chapter 1 Site Preparation<br />

Macintosh Minimum Requirements for <strong>EverSmart</strong> <strong>Jazz</strong><br />

• Apple Power Macintosh 9500 with PCI bus (150 MHz).<br />

• Apple Macintosh system software version 8.1 or higher.<br />

• CD drive (required for software installation).<br />

• 64 MB of available memory (RAM) for the scanning application,<br />

in addition to memory needed for the system software.<br />

• 1 GB internal hard disk is recommended. Its capacity depends on<br />

your needs; for example, image size.<br />

• Color monitor of at least 17 in. with a display capability of millions<br />

of colors.<br />

• 24-bit color display capability.


PC<br />

General Requirements 5<br />

PC Minimum Requirements for <strong>EverSmart</strong> <strong>Jazz</strong><br />

• Pentium II 350 MHz.<br />

• Windows NT 4.0 Workstation (Service pack 4.0 or later)<br />

• CD drive (required for software installation)<br />

• 128 MB SDRAM of available memory for the scanning<br />

application, in addition to memory needed for the system software.<br />

• 6.4 GB internal hard disk is recommended. Its capacity depends on<br />

your needs.<br />

• Color monitor of at least 17 in. with a display capability of 65536<br />

colors.<br />

• 24-bit color display capability.


6 Chapter 1 Site Preparation<br />

1.2 Safety Instructions<br />

To reduce the risk of electric shock, do not remove the cover. Refer servicing to<br />

qualified service personnel.<br />

This warning icon, which appears inside the scanner and in this manual,<br />

indicates that the scanner lamps are hot, and should not be handled before<br />

allowing several minutes for them to cool off.


7<br />

Chapter 2<br />

Unpacking<br />

Unpacking the Scanner. .........................8<br />

UnlockingScrewsandRemovingPacking..........14


8 Chapter 2 Unpacking<br />

2.1 Unpacking the Scanner<br />

The first stage in the installation procedure is to unpack your<br />

<strong>EverSmart</strong> <strong>Jazz</strong> scanner, and place it on the table. This chapter<br />

describes how the scanner package is opened and unpacked.<br />

Unpacking the scanner involves the following steps:<br />

• Opening the box that contains the scanner.<br />

• Lifting the scanner up, and placing it on a table.<br />

• Checking the accessories.<br />

• Saving the packing materials for future use.<br />

Important: If the package is damaged in any way, contact your service center.<br />

Do not proceed with the installation procedure.<br />

To unpack the scanner:<br />

1. Cut the plastic straps carefully. Open the carton top.


Unpacking the Scanner 9<br />

2. Lift the upper cover protecting the scanner.<br />

3. Lift the carton carefully, straight upward from the scanner.


10 Chapter 2 Unpacking<br />

4. Remove the transparent plastic wrapping of the scanner.<br />

Find the holding niche beneath the frame of the scanner<br />

5.<br />

(length-wise), carefully lift the scanner, and place it on the table.<br />

Remember, the scanner weighs approximately 70 kg (156 lb), and two<br />

people are required to lift it.


Unpacking the Scanner 11<br />

Open the Installation Kit carton which contains everything<br />

6.<br />

required for proper scanner installation. Follow the instructions in<br />

the Installation & Maintenance manual.<br />

(1) OPEN ME FIRST<br />

7. Remove the accessory packages.<br />

The following section lists the contents of the installation kit. The<br />

installation procedure continues with Section 2.2 Unlocking Screws<br />

and Removing Packing on page 14.


12 Chapter 2 Unpacking<br />

2.1.1 Installation Kit (required for installation)<br />

• <strong>EverSmart</strong> <strong>Jazz</strong> <strong>Scanners</strong> Installation & Maintenance - Mac and<br />

PC Platforms.<br />

• Scanner software CD for Macintosh computers, including<br />

Installation and Maintenance Guide and User Guide PDF files (in<br />

various languages); Scanner software CD for Windows NT,<br />

including Installation & Maintenance Guide and User Guide PDF<br />

files (in various languages).<br />

• SCSI Interface Board - Adaptec 2903B or compatible<br />

• Power cable, 3m (American type)<br />

• SCSI cable, 2m (C50M/DB 25M)<br />

• Cleaning kit<br />

• Calibration slide<br />

• A flat screwdriver<br />

<br />

For a list of catalog numbers, see Appendix E, Catalog Numbers.<br />

In addition to the components mentioned above, a backup media that<br />

contains the scanner calibration parameters is included in the<br />

Installation Kit.


Unpacking the Scanner 13<br />

2.1.2 Included Kits (not required for installation)<br />

Training package • User Guide - Mac<br />

• User Guide - PC<br />

• Image correction examples<br />

• CD containing computer based<br />

application training (MAC<br />

platform)<br />

Mask kit • User defined masks (10 pieces)<br />

• 35 mm framed slide holder<br />

(1 piece)<br />

• 35 mm framed slide holder<br />

(1 piece) example (1 piece of<br />

each)<br />

The contents of the accessory packages may change from time to time.<br />

Whenever the contents listed in this manual differ from the list enclosed in the<br />

Installation kit, the list in the Installation kit should be considered the correct list.


14 Chapter 2 Unpacking<br />

2.2 Unlocking Screws and Removing Packing<br />

For the procedures in this section, a flat screwdriver is required. This<br />

tool is supplied with the installation kit.<br />

Open the top cover. You will find a sheet of paper with unlocking<br />

1.<br />

instructions.


Unlocking Screws and Removing Packing 15<br />

Lock<br />

Unlock<br />

Insert the flat screwdriver in the niche of the screw located at the<br />

2.<br />

inside upper right corner of the top cover, push the screw inward,<br />

and turn the screw once, clockwise.<br />

Unlock<br />

Lock<br />

Insert the flat screwdriver in the niche of the screw located on the<br />

3.<br />

right hinge of the top cover, and turn the screw once, counterclockwise.


17<br />

Chapter 3<br />

Powering On<br />

Startup Sequence .............................20<br />

Startup Troubleshooting ........................21


18 Chapter 3 Powering On<br />

3.1 Powering on the Scanner<br />

This chapter explains how to power on your <strong>EverSmart</strong> <strong>Jazz</strong> scanner.<br />

1. Locate the power cable in the installation kit.<br />

The power cable is a North American type that complies with US and Canadian<br />

requirements. In order to install a cord meeting European power requirements,<br />

follow the instructions that are attached to the cable wrapping.<br />

The input voltage selection is automatic, and requires no manual setting. The<br />

scanner operates under a standard 100-120/200-240 VAC mains voltage.<br />

Before connecting the power cable to your scanner, please read the Safety<br />

Instructions document (Catalog No. 399Z5H392) attached to the power cable.


Powering on the Scanner 19<br />

2. Make sure that the scanner is switched off.<br />

Connect the power cable to the power supply inlet located on the<br />

3.<br />

back panel.<br />

Connect the other end of the cable to a grounded electrical wall<br />

4.<br />

outlet.


20 Chapter 3 Powering On<br />

5. Switch ON the scanner.<br />

3.2 Startup Sequence<br />

When you switch on the scanner, the Light LED on the operating panel<br />

is green. During the diagnostic self-tests, the Status LED illuminates<br />

according to various stages, as follows:<br />

• The Status LED is red for approximately 12 seconds when the<br />

scanner is switched on.<br />

• The Status LED blinks once while the scanner checks the power<br />

supply.<br />

• The Status LED is green if this step is completed successfully.


Startup Troubleshooting 21<br />

STATUS<br />

LIGHT<br />

3.3 Startup Troubleshooting<br />

If the startup sequence is not completed successfully, one of the<br />

following events will occur:<br />

• The Status LED remains red (possible hardware fault).<br />

• The Status LED remains blinking red (a safety switch was<br />

activated.<br />

<br />

For details, refer to Chapter 9, General Troubleshooting .<br />

It is recommended to continue with the installation procedure even if<br />

one of these events occurs. If the installation procedure is terminated<br />

and cannot be continued, contact your service center.


23<br />

Chapter 4<br />

Software<br />

Installation<br />

Installation Procedure - Macintosh Computers .......24<br />

Installation Procedure - Windows Operating System . . 29


MAC<br />

24 Chapter 4 Software Installation<br />

4.1 Installation Procedure - Macintosh Computers<br />

The <strong>EverSmart</strong> <strong>Jazz</strong> software is provided on a CD-ROM located in the<br />

Installation kit package.<br />

Insert the CD-ROM into the CD-ROM drive; the following<br />

1.<br />

window appears:<br />

<br />

See Appendix C, Documentation Folder for instructions on how to install<br />

and use the documentation located in the Documents folder.


MAC<br />

Installation Procedure - Macintosh Computers 25<br />

Double-click the <strong>EverSmart</strong> 2.5.x Installer icon in the window, the<br />

2.<br />

Installer screen is displayed:<br />

Click Continue;the<strong>EverSmart</strong> Scan 2.5.x Installer window<br />

3.<br />

opens.


MAC<br />

26 Chapter 4 Software Installation<br />

In the scanner list, scroll down to select the scanner you work with<br />

4.<br />

(<strong>EverSmart</strong> <strong>Jazz</strong> or <strong>EverSmart</strong> <strong>Jazz</strong>+).<br />

Click Install, after few seconds the following dialog box is<br />

5.<br />

displayed.<br />

The dialog box shows where, by default, the software will be<br />

installed. If you want to install the software in another location,<br />

select the folder into which you want to install the software.<br />

The folder location you selected is displayed in the Install software<br />

into folder field at the bottom of the dialog box.


MAC<br />

Installation Procedure - Macintosh Computers 27<br />

Click Install.<br />

6.<br />

The installation program continues automatically from this stage<br />

on.<br />

During installation, the counter shows the number of items that<br />

have been installer.<br />

When installation is complete, the following window opens.<br />

7. Click OK.<br />

The scanner software is now installed, and the <strong>EverSmart</strong> Scan 2.5.x<br />

folder automatically opens.


MAC<br />

28 Chapter 4 Software Installation<br />

<strong>EverSmart</strong> <strong>Jazz</strong> Application Folder Contents<br />

<strong>EverSmart</strong> Scan<br />

<strong>EverSmart</strong> Install&Utils<br />

Scitex SCSI Information<br />

<strong>EverSmart</strong> <strong>Jazz</strong> Tables<br />

Release documents<br />

MatchBuilder v.1.0.0f<br />

Service Applications<br />

Scanning application.<br />

For scanner installation and automatic<br />

creation of tables.<br />

Shows which devices are connected to<br />

the SCSI bus.<br />

Scitex-supplied tables.<br />

Contains the <strong>EverSmart</strong> <strong>Jazz</strong> Release<br />

document.<br />

Creates transformation tables which<br />

simulate proof or final print colors on<br />

your monitor.<br />

Scanner Drive <strong>EverSmart</strong><br />

<strong>EverSmart</strong> Diag.<br />

<strong>EverSmart</strong> Calib.<br />

Used by the scanning application.<br />

Intended for service engineers only.<br />

Intended for service engineers only.<br />

The software version appears in the title bar of the screen. Do not place<br />

applications of different software versions in the same application folders.


PC<br />

Installation Procedure - Windows Operating System 29<br />

4.2 Installation Procedure - Windows Operating System<br />

The <strong>EverSmart</strong> <strong>Jazz</strong> software is provided on a CD-ROM located in the<br />

Installation kit package. This software is suitable only for <strong>EverSmart</strong><br />

<strong>Jazz</strong> scanners.<br />

1. Restart your computer, and log on as an Administrator.<br />

Insert the CD-ROM into the CD-ROM; after few seconds, the<br />

2.<br />

Scanner Setup window appears.<br />

Click to select Install <strong>EverSmart</strong> <strong>Jazz</strong> Scanner Application;the<br />

3.<br />

Setup prepares the Installation Wizard.


PC<br />

30 Chapter 4 Software Installation<br />

The Welcome window opens.<br />

Click Next to continue with the Setup program; the Choose<br />

4.<br />

Destination Location window opens. It shows where, by default,<br />

the Scanner folder will be placed.


PC<br />

Installation Procedure - Windows Operating System 31<br />

Click Next to install the <strong>EverSmart</strong> <strong>Jazz</strong> application to the default<br />

5.<br />

folder.<br />

To place the folder in another location, click Browse; theChoose<br />

Ø<br />

Folder window appears.<br />

Select the storage location, and click OK to return to the Choose<br />

Ø<br />

Destination Location window. The folder location now appears in<br />

the window.<br />

In the Choose Destination Location window, click Next;theSetup<br />

6.<br />

Type window appears.


PC<br />

32 Chapter 4 Software Installation<br />

Click to select a setup type, then click Next; theSelect Program<br />

7.<br />

Folder window appears.<br />

Click Next to continue with the installation.<br />

8.<br />

During installation, a progress bar shows what percentage of time<br />

has elapsed.<br />

Setup starts copying files to your computer.


PC<br />

Installation Procedure - Windows Operating System 33<br />

When Setup has finished copying files, the Setup Complete<br />

9.<br />

window opens.<br />

Click Finish to restart your computer. Remove the CD-ROM from<br />

10.<br />

the computer.<br />

The scanner software is now installed, and the <strong>EverSmart</strong> <strong>Jazz</strong><br />

application folder automatically opens.


PC<br />

34 Chapter 4 Software Installation<br />

<strong>EverSmart</strong> <strong>Jazz</strong> Application Folder Contents<br />

Diagnostics<br />

<strong>EverSmart</strong> Install&Utils<br />

<strong>EverSmart</strong> <strong>Jazz</strong>1.0.0<br />

<strong>EverSmart</strong> <strong>Jazz</strong>Tables<br />

Release documents f<br />

Uninstall <strong>EverSmart</strong> <strong>Jazz</strong><br />

Intended for service engineers only.<br />

For scanner installation and automatic<br />

creation of tables.<br />

Scanning application.<br />

Scitex-supplied tables.<br />

Contains the <strong>EverSmart</strong> <strong>Jazz</strong> Release<br />

document.<br />

For uninstalling the scanner software.<br />

The software version appears in the title bar of the screen. Do not place<br />

applications of different software versions in the same application folders.


35<br />

Chapter 5<br />

SCSI Configuration<br />

ConfigurationOptions..........................37<br />

SCSI Board Installation (if required) ...............41<br />

Connecting Options. ...........................45<br />

SCSIDriverInstallation.........................48<br />

SettingtheSCSIID............................49


36 Chapter 5 SCSI Configuration<br />

The next stage in the installation procedure is to connect your scanner<br />

to the computer.<br />

Important: Before connecting the scanner, make sure that the computer, the<br />

scanner, and all other devices are switched off.<br />

SCSI configuration involves the following steps:<br />

• Choosing your configuration.<br />

• Installing the SCSI Board (if required).<br />

• Installing the SCSI driver (refer to the SCSI Host Adapter<br />

Installation Guide).<br />

• Connecting the scanner to the computer.<br />

• Checking the termination.<br />

• Setting the SCSI ID.<br />

Each step is explained in the relevant section below.


Configuration Options 37<br />

5.1 Configuration Options<br />

Ø<br />

Set up your scanner less than 6 meters from the computer,<br />

according to one of the configurations described in the following<br />

pages.<br />

Instructions for connecting each configuration appear together with the<br />

figure.<br />

Ø<br />

From the installation kit, remove the SCSI cable, which include the<br />

following description:<br />

SCSI cable, 2 m (from C50M-connector to DB25M-connector)


38 Chapter 5 SCSI Configuration<br />

SCSI Connector Location<br />

The SCSI-related components on the scanner consist of the following:<br />

• Two SCSI connectors (1), (2)<br />

• A SCSI ID selector (3)<br />

• Aterminatorswitch(4)<br />

(1)<br />

(4)<br />

(2)<br />

(3)


Configuration Options 39<br />

Connector Sockets<br />

There are two connector sockets, identified by the SCSI icon. The<br />

sockets are located on the SCSI connector panel on the back of the<br />

scanner, as shown in the following diagram.<br />

(1)<br />

(2)<br />

The connectors are connected in parallel, to enable a "daisy-chain"<br />

SCSI configuration.<br />

1. 50 pin SCSI connector (1)<br />

2. 25 pin SCSI connector (2)


40 Chapter 5 SCSI Configuration<br />

SCSI ID Selector<br />

Each device on the SCSI chain is assigned a unique identification (ID)<br />

number. The ID of the scanner is set by pressing the SCSI ID selector,<br />

which is located on the back panel of the scanner, as shown in the<br />

following diagram.<br />

Terminator Switch<br />

The last device on the SCSI chain requires a terminator. If the scanner<br />

is the last device on the SCSI chain, the terminator switch, located on<br />

the back panel of the scanner, should be switched ON, asshowninthe<br />

diagram above.


SCSI Board Installation (if required) 41<br />

5.2 SCSI Board Installation (if required)<br />

The next stage in the installation procedure is to connect the SCSI<br />

board to your computer.<br />

Please consult your System Administrator before starting the SCSI board<br />

installation process.<br />

SCSI configuration involves the following steps:<br />

Before starting, turn OFF power to the computer, and disconnect the power cord.<br />

Then, ground yourself by touching an unpainted surface of the computer case.<br />

Remove the cover from your computer following the<br />

1.<br />

manufacturer’s instructions.<br />

The above illustration is a general description of removing a computer<br />

cover.


42 Chapter 5 SCSI Configuration<br />

Locate an unused PCI expansion slot (typically white or ivory) and<br />

2.<br />

remove the expansion slot cover screw, then remove the expansion<br />

slot cover. Save the slot cover screw for use in Step 5.<br />

Expansion<br />

slot cover<br />

PCI Expansion<br />

slots (typically<br />

white or ivory)<br />

Computers may have vertical or horizontal expansion slots. Refer to your<br />

computer manual to locate the PCI slots.


SCSI Board Installation (if required) 43<br />

Remove the SCSI board from its anti-static packaging. Always<br />

3.<br />

handle the board by its edges.<br />

Discharge any static electricity built-up before handling the SCSI<br />

board by touching a grounded metal object (like the exposed metal<br />

parts on the back of your computer).<br />

Goldfingers (do not<br />

touch these)


44 Chapter 5 SCSI Configuration<br />

Carefully insert the SCSI board into the PCI expansion slot,<br />

4.<br />

pressing it down firmly so the gold fingers are seated in the slot<br />

(see the figure in Step 3). Secure the SCSI board with the slot<br />

cover screw you removed in Step 2..<br />

SCSI Board<br />

installedina<br />

PCI Expansion<br />

slot<br />

5. Place the computer cover back.


Connecting Options 45<br />

5.3 Connecting Options<br />

Option 1: Scanner connected directly to the computer -<br />

RECOMMENDED<br />

(1)<br />

COMPUTER<br />

SCANNER<br />

25 PIN 50 PIN 25 PIN<br />

CABLE (1)<br />

Ø<br />

Connect the 2-meter SCSI cable (1) between the 50-pin connector<br />

socket on the scanner and the SCSI port on the back panel of the<br />

computer.<br />

Switch the terminator ON.<br />

Ø


46 Chapter 5 SCSI Configuration<br />

Option 2: Scanner connected to the computer through SCSI device -<br />

NOT RECOMMENDED<br />

(1)<br />

COMPUTER<br />

PERIPHERIAL<br />

DEVICE<br />

SCANNER<br />

25 PIN 50 PIN 50 PIN 50 PIN 25 PIN<br />

VENDOR CABLE<br />

CABLE (1)<br />

Ø<br />

Ø<br />

Connect the 2-meter SCSI cable (1) between the 25-pin connector<br />

socket on the scanner and the SCSI port on the SCSI peripheral<br />

device.<br />

Connect the peripheral vendor cable between the peripheral device<br />

and the computer.<br />

Switch the terminator ON.<br />

Ø


Connecting Options 47<br />

Option 3: Scanner connected between the computer and SCSI device -<br />

NOT RECOMMENDED<br />

(1)<br />

COMPUTER<br />

SCANNER<br />

PERIPHERIAL<br />

DEVICE<br />

25 PIN 50 PIN 25 PIN 50 PIN Terminator<br />

CABLE (1)<br />

VENDOR CABLE<br />

Ø<br />

Ø<br />

Ø<br />

Connect the 2-meter SCSI cable (1) between the 50-pin connector<br />

socket on the scanner and the SCSI port on the back panel of the<br />

computer.<br />

Connect the peripheral vendor cable between the peripheral device<br />

and the scanner.<br />

Switch the terminator OFF.<br />

Connect the SCSI terminator to the peripheral device.<br />

Ø


48 Chapter 5 SCSI Configuration<br />

5.4 SCSI Driver Installation<br />

Macintosh computers<br />

<br />

If the SCSI Adapter CD is included in the kit, use it according to the<br />

manufacturer’s instructions. If not, please follow the instructions in the<br />

<strong>EverSmart</strong> <strong>Jazz</strong> Release Notes which you can find in the Release Documents<br />

<strong>Jazz</strong> folder.<br />

Windows computers<br />

<br />

For details on installing the SCSI driver on PC platform, refer to the SCSI Host<br />

Adapter Installation Guide included in your installation kit.


MAC<br />

Setting the SCSI ID 49<br />

5.5 Setting the SCSI ID<br />

The scanner has to be identified by the system; this is done by giving<br />

the scanner a device identification number (ID).<br />

Ø<br />

Ø<br />

Switch ON the computer, and all other SCSI devices.<br />

Press the SCSI ID selector on the back panel of the scanner, to the<br />

ID number that you want. The ID number should be selected from<br />

one of the unoccupied IDs on the SCSI network.<br />

Important:<br />

1. All the instructions refer to the SCSI bus connected to the scanner.<br />

2. Make sure that no two devices have the same ID number.<br />

3. The ID number of the computer is always 7. The number of your scanner,<br />

therefore, should be between 0 and 6.


MAC<br />

50 Chapter 5 SCSI Configuration<br />

Ø<br />

Ø<br />

Ø<br />

Switch ON the scanner.<br />

Verify that the scanner is in ready status (the Status LED is green).<br />

This will take approximately 12 seconds.<br />

Double-click the Scitex SCSI Information icon located in the<br />

<strong>EverSmart</strong> folder.<br />

The SCSI chain is scanned, and the chain mapping is displayed, as<br />

shown in the following figure:<br />

All devices connected to the chain appear as icons, together with<br />

their ID number.<br />

If any of the devices are switched off, SCSI Information does not list the device's<br />

ID number.<br />

The Scitex SCSI Information window above is displayed on the Macintosh.<br />

Ø<br />

From the SCSI Bus list, select Adaptec SCSI card 2906 or any of<br />

the provided SCSI cards.<br />

Close the window by clicking the box in the upper left corner.<br />

Ø


51<br />

Chapter 6<br />

Installation<br />

Program<br />

Stage 1: Launch the Installation & Utilities Application . 52<br />

Stage 2: Begin the Installation Procedure. ..........53<br />

Stage3:EntertheSerialNumber.................54<br />

Stage 4: Prepare the Scanner. ...................57<br />

Stage 5: Automatic Diagnostics Check. ............59<br />

Stage6:AutomaticOpticsCheck.................60<br />

Stage7:CreateTables.........................61<br />

Stage8:BackuptoDisketteorExternalMedia.......62<br />

Stage9:QuitInstallation........................64<br />

Troubleshooting for the Installation & Utilities Program 65


52 Chapter 6 Installation Program<br />

At this stage of the installation procedure, your scanner is switched<br />

ON, is connected to the system, and the scanning software was loaded<br />

in the computer.<br />

This chapter explains the Full Install procedure, which takes<br />

approximately 45 minutes.<br />

<br />

If a problem arises during the Full Install procedure, refer to<br />

Section 6.10 Troubleshooting for the Installation & Utilities Program on page 65.<br />

For partial installation (Custom Install) refer to Section 7.2 Custom Install on<br />

page 76.<br />

6.1 Stage 1: Launch the Installation & Utilities Application<br />

If you are working on PC platform, you have to log on as an<br />

1.<br />

Administrator.<br />

2. Open the Scanner application folder.<br />

Double-click the <strong>EverSmart</strong> Install&Utils icon; the following<br />

3.<br />

screen is displayed.


Stage 2: Begin the Installation Procedure 53<br />

After several seconds, the Installation & Utilities screen appears,<br />

as follows.<br />

6.2 Stage 2: Begin the Installation Procedure<br />

Ø<br />

Click Continue.<br />

The following scanner installation screen is displayed:<br />

On PC platform, the Diagnostics Checks option does not exist.<br />

Ø<br />

In this screen, all the Installation Stage options are pre-selected,<br />

and the options are disabled.<br />

Click Install to continue with the installation process.


54 Chapter 6 Installation Program<br />

6.3 Stage 3: Enter the Serial Number<br />

Ø<br />

The Scanner Serial Number screen is displayed:<br />

Ø<br />

Enter the scanner serial number. The number is displayed in one of<br />

the following locations:<br />

• On the label below the barcode on the back of the scanner (see<br />

page 55).<br />

• On the calibration slide (see page 56).<br />

Each of the locations is shown in the illustrations on the following<br />

pages. The number consists of several digits with a character<br />

between them (for example, 9912M00000).<br />

Use an uppercase letter for the character between the digits.<br />

Click Confirm.<br />

Ø<br />

On a Macintosh computer, scanner parameters are now automatically<br />

copied to the <strong>EverSmart</strong>Scan.Prefs file (located in the Preference<br />

folder which is in the System folder).<br />

On a Windows computer, scanner parameters are automatically copied<br />

to the Registry Editor\Hkey Local Machine\Software\Scitex.


Stage 3: Enter the Serial Number 55<br />

The scanner serial number on the label below the barcode on the back<br />

of the scanner, as shown in the following illustration:<br />

Make sure to enter all the digits. Use an uppercase letter for the character<br />

between the digits.


56 Chapter 6 Installation Program<br />

The scanner serial number on the calibration slide appears in the upper<br />

right corner, as shown in the following illustration:


Stage 4: Prepare the Scanner 57<br />

6.4 Stage 4: Prepare the Scanner<br />

Ø<br />

A message is displayed instructing you to clean the glass and place<br />

the calibration slide on the scanner.<br />

!<br />

Ø<br />

Ø<br />

Prepare the cleaning kit and the calibration slide (in the<br />

Installation Kit package).<br />

Clean the base glass and upper glass plates. We recommend<br />

using domestic glass cleaning solution to clean all flat glass<br />

surfaces, as it leaves no trace after drying. The cleaning solution<br />

should not contain wax or ammonia. (Clear) Windex is<br />

recommended. Be sure not to pour cleaning solution directly on the<br />

glass, as it might leak inside.


58 Chapter 6 Installation Program<br />

Ø<br />

Place the calibration slide on the base glass: the pin holes in the<br />

slide should fit over the two right-hand pins at the top side of the<br />

base glass. The sticker on the calibration slide should be in the<br />

upper right-hand corner.<br />

The slide should appear as follows.<br />

Close the top cover, and click Proceed.<br />

Ø


MAC<br />

Stage 5: Automatic Diagnostics Check 59<br />

6.5 Stage 5: Automatic Diagnostics Check<br />

Ø<br />

An automatic diagnostics check is performed, and the following<br />

window appears showing the results:<br />

The results can be either Passed or Fail.<br />

If all tests pass, the application automatically moves on to the next<br />

stage.<br />

If any test fails, refer to Section 6.10 Troubleshooting for the<br />

Installation & Utilities Program on page 65.


60 Chapter 6 Installation Program<br />

6.6 Stage 6: Automatic Optics Check<br />

Ø<br />

An automatic Optics check is now performed, and the following<br />

message window appears showing the test results:<br />

Ø<br />

TheresultscanbeeitherPassed or Out of Tolerance.<br />

If the test passes, the application automatically moves on to the<br />

next stage.<br />

If the test result is Out of Tolerance, refer to<br />

Section 6.10 Troubleshooting for the Installation & Utilities<br />

Program on page 65.<br />

On PC platform, the Optics check window may look somewhat different.


Stage 7: Create Tables 61<br />

6.7 Stage 7: Create Tables<br />

Ø<br />

The Create Tables window is displayed, as follows:<br />

A fully automatic procedure for creating new machine tables is<br />

now performed. The duration of this procedure is approximately<br />

20 minutes, and a progress bar at the bottom of the screen shows<br />

the percentage of time that has elapsed.<br />

On a Macintosh computer, scanner parameters are now<br />

automatically copied to the <strong>EverSmart</strong>Scan.Prefs file (located in<br />

the Preference folder which is in the System folder).<br />

On a Windows computer, scanner parameters are automatically<br />

copied to the Registry Editor\Hkey Local Machine\Software\Scitex.


62 Chapter 6 Installation Program<br />

6.8 Stage 8: Backup to Diskette or External Media<br />

Ø<br />

At this point, a message is displayed asking if you want to back up<br />

the generated table results to a diskette or other external media.<br />

Ø<br />

Click Yes.<br />

As a precaution, we recommend that you back up the newly<br />

created tables. The following dialog box is displayed.<br />

You can choose where to save the parameters: Diskette, <strong>Jazz</strong>,<br />

Optical, etc.


Stage 8: Backup to Diskette or External Media 63<br />

If you choose Diskette, first insert a new diskette (formatted or<br />

unformatted) into the disk drive. Do not use the backup diskette<br />

provided with the scanner. The following dialog box is displayed.<br />

Ø<br />

Click Select >>diskette name>>; the program ejects the diskette.<br />

A message is displayed asking you to insert a diskette to continue.<br />

Ø<br />

Insert a diskette; a message is displayed confirming that the saving<br />

has been successfully completed.<br />

On PC platform, insert a diskette in a PC format.<br />

On Mac platform, the diskette can be in a Mac or a PC format.<br />

Click Done to return to the main menu.<br />

Ø


64 Chapter 6 Installation Program<br />

6.9 Stage 9: Quit Installation<br />

Ø<br />

After the tables are copied to the media, a message window is<br />

displayed confirming the installation has been successfully<br />

completed.<br />

Ø<br />

Ø<br />

Click Done to return to the main menu.<br />

On PC platform, if an error message is displayed during the installation<br />

process, refer to Section 7.8 Diagnostics - Windows Operating System on<br />

page 87.<br />

You may now remove the calibration slide.<br />

Important: After you finish the installation procedure, keep the calibration slide<br />

in a place that is dark, cool, and safe. You may need to use it occasionally.<br />

Installation Results<br />

Results of the installation procedure are written to the<br />

Install&Util_results file in the log folder.<br />

<br />

See Section 7.6 <strong>EverSmart</strong> Scan Log Folder - Macintosh Computers on page 84<br />

for an explanation of this file.<br />

General Tips<br />

To make the most of your <strong>EverSmart</strong> <strong>Jazz</strong> scanner and its capabilities,<br />

we suggest the following hands-on course of action:<br />

Ø<br />

Practice performing your own scans, using your own originals, to<br />

get the feel of the scanner operation and workflow. Use the training<br />

kit to help you get acquainted with <strong>EverSmart</strong> <strong>Jazz</strong> operation.


Troubleshooting for the Installation & Utilities Program 65<br />

6.10 Troubleshooting for the Installation & Utilities Program<br />

Problem<br />

Description and Solution<br />

on page...<br />

Serial Number Mismatch 66<br />

Serial Number Mismatch (second time) 67<br />

Wrong Media Inserted 67<br />

SCSI Communication Failure 68<br />

Diagnostics Check Failure 69<br />

Calibration Slide Incorrectly Placed 70<br />

Optics Check: Out of Tolerance 71


66 Chapter 6 Installation Program<br />

Problem<br />

Serial Number Mismatch<br />

If there is a mismatch between the serial number on the scanner label,<br />

and the number in the scanner parameters (those saved in the scanner),<br />

the program requests the correct serial number a second time.<br />

For example, in the following figure, the last serial number digit, 3, is<br />

incorrect, and should be 0:<br />

Solution<br />

Ø<br />

Check the number carefully, enter it into the edit box, and click<br />

Confirm.<br />

Use an uppercase letter for the character between the digits.


Troubleshooting for the Installation & Utilities Program 67<br />

Problem<br />

Serial Number Mismatch (second time)<br />

If the number entered still does not match, a message window appears<br />

on the screen requesting insertion of the scanner parameters backup<br />

media.<br />

Solution<br />

Ø<br />

Ø<br />

An original, factory-produced, parameters backup media is<br />

supplied with the scanner. The media is located in the installation<br />

kit. Insert this media into the drive.<br />

If no parameter media exists, click No Backup.<br />

Default parameters will automatically be created.<br />

Problem<br />

Wrong Media Inserted<br />

If the backup media also has a serial number mismatch, or a wrong<br />

media has been inserted, a message window appears requesting<br />

insertion of the correct media.<br />

Solution<br />

Ø<br />

If no other parameter media exists, click No backup.<br />

Default parameters will automatically be created.


68 Chapter 6 Installation Program<br />

Problem<br />

SCSI Communication Failure<br />

If the automatic diagnostics check of SCSI communication fails, a<br />

message window appears to inform you of such.<br />

Solution<br />

Ø<br />

Ø<br />

Ø<br />

Ø<br />

Click Stop to quit the Installation & Utilities program.<br />

Switch off the scanner and the computer.<br />

Check all SCSI connections: cables, terminators, and<br />

configuration.<br />

<br />

Refer to SCSI Communication Problems in Chapter 9, General<br />

Troubleshooting.<br />

Run the Installation & Utilities program again.


MAC<br />

Troubleshooting for the Installation & Utilities Program 69<br />

Problem<br />

Diagnostics Check Failure<br />

If any of the scanner hardware does not pass the diagnostics check, a<br />

fail message appears in the Diagnostics Checks window. The buttons<br />

become active.<br />

Click More Info to obtain additional information about the test failure.<br />

Solution<br />

Ø<br />

Ø<br />

Click Continue to continue with the installation program.<br />

If the Continue button is disabled, click Quit to exit to the main<br />

screen, and contact your service center.


70 Chapter 6 Installation Program<br />

Problem<br />

Calibration Slide Incorrectly Placed<br />

The scanner verifies that the calibration slide has been placed on the<br />

scan carriage, and is inserted correctly. If this test fails, a message<br />

repeats the request to place the calibration slide correctly.<br />

Solution<br />

Ø<br />

Follow the instructions in the screen, and click Proceed.<br />

<br />

Refer to the figures in Section 6.4 Stage 4: Prepare the Scanner on<br />

page 57 for the correct way to place the calibration slide.


Troubleshooting for the Installation & Utilities Program 71<br />

Problem<br />

Optics Check: Out of Tolerance<br />

During the Optics check, an OutofTolerancemessage is received:<br />

l<br />

On PC platform, the Optics check window may look somewhat different.<br />

Solution<br />

In this case, the previously generated tables remain intact. New tables<br />

will not be generated.<br />

Ø<br />

Click Continue; thefollowingmessageisdisplayed:<br />

Ø<br />

Ø<br />

Click Stop to return to the main window.<br />

Retry your scan using the previously generated parameters.<br />

If the problem persists, contact your service center.


73<br />

Chapter 7<br />

Utilities<br />

StatusScreen................................75<br />

CustomInstall................................76<br />

Scanner Checks ..............................78<br />

CreateTables................................80<br />

BackupMedia................................82<br />

<strong>EverSmart</strong> Scan Log Folder - Macintosh Computers . . 84<br />

Log Folders - Windows Operating System ..........85<br />

Diagnostics - Windows Operating System ..........87


74 Chapter 7 Utilities<br />

This chapter describes the installation program utilities and the log<br />

folder.<br />

The Installation & Utilities program is used to install the scanner. The<br />

program contains the following utility options:<br />

• Custom Install page 76<br />

• Scanner checks - Macintosh computers page 78<br />

• Scanner checks - Windows computers page 79<br />

• Create Tables page 80<br />

• Backup Media page 82<br />

• Diagnostics - Windows computers page 87<br />

The utilities are described in the following pages. The <strong>EverSmart</strong> Scan<br />

Log Folder is described at the end of this chapter.


MAC<br />

Status Screen 75<br />

7.1 Status Screen<br />

While a utility program is running, you can view the progress of the<br />

process, by selecting the Show Status option from the Windows menu,<br />

in Menu bar.<br />

After you select the Show Status option, the following window is<br />

displayed.<br />

In the Status window, successful tests are marked with a green check<br />

mark, and failed tests are marked with a red X.


76 Chapter 7 Utilities<br />

7.2 Custom Install<br />

(accessed via the Installation Program item)<br />

The Custom Install utility is used to perform a partial scanner<br />

installation.<br />

To perform a custom installation, do the following:<br />

Double-click the <strong>EverSmart</strong> Install&Utils icon. In the window that<br />

is displayed, select the Installation Program option.<br />

Ø<br />

Ø<br />

Click Continue.


Custom Install 77<br />

Ø<br />

In the <strong>EverSmart</strong> <strong>Jazz</strong> Installation window that is displayed, select<br />

the Custom Install option.<br />

On PC platform, the Diagnostics Checks option does not exist.<br />

When you select Custom Install,theInstallation Stage options are<br />

enabled, and the check boxes are cleared.<br />

The Installation Stages include the following:<br />

Load Parameters<br />

Diagnostics Checks<br />

Optics Check<br />

Create Tables<br />

Parameters are loaded into the<br />

computer from the scanner.<br />

Scanner hardware functions are tested<br />

and displayed.<br />

Optic adjustment is tested.<br />

New machine tables are created.<br />

Ø<br />

Select one or more option, and click Install. The stages that you<br />

selected are executed automatically.<br />

Results file<br />

Upon completion of the Custom Install, the results are written to the<br />

Install&Util_results file. An explanation of this file is provided later in<br />

this chapter.


78 Chapter 7 Utilities<br />

7.3 Scanner Checks<br />

The Scanner Checks utility checks the scanner modules and optics.<br />

You are required to activate this utility only when a scanner operational<br />

problem arises.<br />

To activate this utility:<br />

Double-click the <strong>EverSmart</strong> Install&Utils icon; in the window that<br />

appears, select the Scanner Checks option.<br />

Ø<br />

Ø<br />

Click Continue; a message is displayed instructing you to clean<br />

the glass and place the calibration slide on the scanner.<br />

<br />

See the cleaning instructions in Stage 4, page 57.<br />

Ø<br />

Follow the instructions, and click Proceed.<br />

The Scanner Checks procedure continues automatically, with the<br />

Diagnostics and Optics checks.


Scanner Checks 79<br />

Ø<br />

If the Diagnostics check and the Optics check pass successfully,<br />

the following message window is displayed:<br />

Ø<br />

Ø<br />

If an error occurs during the Diagnostics check or the Optics<br />

check, in the error message window that appears, click Continue.<br />

Test results are written to a results file described below.<br />

At the end of the process, the following message window is<br />

displayed:<br />

Contact your service center for help.<br />

Ø<br />

Results file<br />

Upon completion of the Scanner Checks, the results are written to the<br />

file Install&Util_results_file.<br />

On Macintosh platform, for an explanation of this file, refer to<br />

Section 7.6 <strong>EverSmart</strong> Scan Log Folder - Macintosh Computers on<br />

page 84.<br />

On PC platform, for an explanation of this file, refer to Section 7.7 Log<br />

Folders - Windows Operating System on page 85.


80 Chapter 7 Utilities<br />

7.4 Create Tables<br />

Select this option in the Installation & Utilities screen when tables<br />

need to be created.<br />

Ø<br />

Double-click the <strong>EverSmart</strong> Install&Utils icon. In the window that<br />

is displayed, select Create Tables.<br />

Click Continue; the following window is displayed:<br />

Ø<br />

Ø<br />

There are two options in the Create tables box:<br />

• Create All (the default option)<br />

• Cast Removal Factors<br />

Select the desired option, and click Activate.<br />

Ø


Create Tables 81<br />

Ø<br />

A message is displayed instructing you to clean the glass and place<br />

the calibration slide on the scanner.<br />

<br />

See the cleaning instructions in Section 6.4 on page 57.<br />

Ø<br />

Follow the instructions, and click Proceed.<br />

The Create Tables window is displayed, and a fully automatic<br />

procedure begins.<br />

<br />

Refer to Stage 7: Create Tables, on page 61 and Stage 8: Backup to<br />

Diskette or External Media, on page 62<br />

At the end of the process, the following completion message is<br />

displayed:<br />

Results file<br />

Upon completion of the table creation procedure, the results are written<br />

to the file Install&Util_results_file. An explanation of this file is<br />

provided later in this chapter.


82 Chapter 7 Utilities<br />

7.5 Backup Media<br />

Choose this option when parameters have to be:<br />

• Loaded from the backup media to the computer, and to the scanner<br />

memory. This is a fast installation, without any optics check or<br />

creation of tables. You may need to use this option, for example, if<br />

your <strong>EverSmart</strong>Scan.Prefs file is erased or becomes corrupted.<br />

• Saved from the computer to a Backup Scanner Parameters<br />

media.<br />

Ø<br />

Double-click the <strong>EverSmart</strong> Install&Utils icon. In the window that<br />

is displayed, select the Backup Scanner Parameters option.<br />

Ø<br />

Click Continue. The following window is displayed:<br />

On PC platform, insert<br />

adisketteinaPC<br />

format.


Backup Media 83<br />

Ø<br />

Ø<br />

Ø<br />

Select the Save to Backup Media option to save the parameters on<br />

the computer to a backup media.<br />

or<br />

Select the Load from Backup Media option to overwrite the<br />

parameters on the computer. This option enables faster installation<br />

(when previous parameters are to be used).<br />

Select Browse to set media or required destination, and follow the<br />

instructions that appear on the screen.<br />

<br />

Refer to Section 6.8 Stage 8: Backup to Diskette or External Media on<br />

page 62 for details.<br />

At the end of the process, a completion message window is<br />

displayed on the screen.<br />

Results file<br />

Upon completion of the backup procedure, the results are written to the<br />

file Install&Util_results_file.<br />

On Macintosh platform, for an explanation of this file, refer to<br />

Section 7.6 <strong>EverSmart</strong> Scan Log Folder - Macintosh Computers on<br />

page 84.<br />

On PC platform, for an explanation of this file, refer to Section 7.7 Log<br />

Folders - Windows Operating System on page 85.


MAC<br />

84 Chapter 7 Utilities<br />

7.6 <strong>EverSmart</strong> Scan Log Folder - Macintosh Computers<br />

<strong>EverSmart</strong> <strong>Jazz</strong> activity is automatically recorded in the<br />

Install&Util_results_file and <strong>EverSmart</strong>_Install&Util_LogFile.<br />

These files are located in the <strong>EverSmart</strong> Scan_Log Folder, and contain<br />

text information concerning the test results and descriptions of the test<br />

processes.<br />

When you run the scanner application from the folder created during installation,<br />

the <strong>EverSmart</strong> Scan Log folder is automatically created in the same folder. All<br />

log files are written to this log folder. If, for any reason, you have dragged the<br />

application to another location, a new <strong>EverSmart</strong> Scan Log folder is created in<br />

the same new location.<br />

You may need to use the information stored in these files. For example,<br />

if you have to report to your service center, they will want to receive a<br />

copy of this log folder.<br />

You can send the log folder in one of the following ways:<br />

• E-mail the files to the service center.<br />

• Print out the files in the folder (they can be opened with most word<br />

processors), and fax them to your service center.<br />

• Copy the folder to a diskette, and mail the diskette to the service<br />

center.


PC<br />

Log Folders - Windows Operating System 85<br />

7.7 Log Folders - Windows Operating System<br />

<strong>EverSmart</strong> Scan Log Folder<br />

If any of the test fail, contact your local service center. You may<br />

be requested to provide the log file created by the Scanner check<br />

procedure for a thorough examination by a specialist. In order to access<br />

the <strong>EverSmart</strong> Log Folder, perform the following:<br />

Ø<br />

Ø<br />

In the My Computer window, click on your local hard disk (for<br />

example, C).<br />

Execute the following sequence:<br />

Program FilesàScitexà<strong>EverSmart</strong> <strong>Jazz</strong>à<strong>EverSmart</strong> Log<br />

Folder; the <strong>EverSmart</strong> Log Folder window is displayed.<br />

The two log files are Install&Util_Log File and Install&Util_results<br />

file.


PC<br />

86 Chapter 7 Utilities<br />

Jserver - Diagnostics Log Folder<br />

To access the JServer folder, perform the following:<br />

Ø<br />

Execute the following sequence: StartàProgramsà<strong>EverSmart</strong><br />

<strong>Jazz</strong>àDiagnosticsàResults; the following window is displayed.<br />

Log.html<br />

Log List.html<br />

LogsFrame.html<br />

Accumulating detail information about the recent test.<br />

It can also be opened through the Diagnostic<br />

program.<br />

Accumulating formers Log.html files.<br />

Accumulating formers Log.html files with feature to<br />

viewthelogsonthesameframe.


PC<br />

Diagnostics - Windows Operating System 87<br />

7.8 Diagnostics - Windows Operating System<br />

The <strong>EverSmart</strong> <strong>Jazz</strong> Diagnostics program is a software package that<br />

enables testing the <strong>EverSmart</strong> <strong>Jazz</strong> hardware (Power Supply, Boards,<br />

Mechanics, Optics, etc.). The Diagnostic package is included in the<br />

<strong>EverSmart</strong> <strong>Jazz</strong> installation CD-ROM, and is part of the <strong>EverSmart</strong><br />

scanner software application installation (Scitex CD ROM).<br />

7.8.1 System Requirements<br />

In order to run the Diagnostics program, you must have Internet<br />

Explorer 4.01 or newer installed in your computer. If it is not installed,<br />

you can install it from the Scitex CD-ROM supplied in the kit.<br />

7.8.2 Installing Internet Explorer 4.0.1<br />

To install Internet Explorer 4.01 or higher:<br />

Insert the Scitex CD-ROM into the CD Drive.; the Scanner Setup<br />

1.<br />

window is displayed.<br />

Click Install Internet Explorer 4.01, and follow the installer<br />

2.<br />

program instructions.<br />

When the installation is successfully completed, you can run the<br />

3.<br />

Diagnostics program.


PC<br />

88 Chapter 7 Utilities<br />

7.8.3 Running the Diagnostic Application<br />

To run the Diagnostics application:<br />

1. Execute the following sequence: StartàProgramsà<strong>EverSmart</strong><br />

<strong>Jazz</strong>à Diagnosticsà Diagnostics; theStartup process begins.<br />

During the Startup process the software:<br />

• verifies the communication between the host and the scanner.<br />

• initializes the communication to electronic boards and reads<br />

the basic board data.<br />

• identifies the hardware and the software configuration.<br />

The failure results of the Startup process and a start-up information<br />

summary are shown in the <strong>EverSmart</strong> Service Diagnostics window<br />

that is displayed automatically when the startup process is<br />

completed.<br />

In addition, a red/green indicator is lit on the right side of the<br />

<strong>EverSmart</strong> Service Diagnostics window.<br />

The following tests are available:<br />

• Power Supply&Electronic boards<br />

• Mechanics<br />

• Optical


PC<br />

Diagnostics - Windows Operating System 89<br />

In the <strong>EverSmart</strong> Service Diagnostics window, select the<br />

2.<br />

Diagnostics Tree option; all the options in the Diagnostics Tree are<br />

automatically selected.<br />

Click the Run icon at the top left corner of the window to launch<br />

3.<br />

the Diagnostics program.<br />

To run the Diagnostics program in the loop, click the RunInLoop<br />

4.<br />

icon.<br />

5. To exit the Diagnostics application, click the Exit icon.


PC<br />

90 Chapter 7 Utilities<br />

6. The test results appear in the Last Result field as PASS or FAIL.<br />

Detailed information about the tests results are located in the<br />

JServer/Html folder. To view the log information, perform the<br />

following:<br />

• From the View menu, select Test Log File,thenclickResults<br />

History, thenclickStartup Summary.<br />

<br />

For more information, refer to Section Jserver - Diagnostics Log Folder on<br />

page 86.


91<br />

Chapter 8<br />

Maintenance<br />

LampReplacement............................92<br />

CleaningtheGlass...........................104


92 Chapter 8 Maintenance<br />

This chapter explains how you maintain the following <strong>EverSmart</strong> <strong>Jazz</strong><br />

components.<br />

• Lamps Replacing:<br />

• Transparency lamp<br />

• Reflective lamp<br />

• Glass plates Cleaning the upper and base glass.<br />

8.1 Lamp Replacement<br />

Thescanneroperateswiththreefluorescentlamps,asfollows:<br />

• One transparency lamp.<br />

• Two reflective lamps.<br />

Replace the lamps when:<br />

• The light level is too low (a message is displayed). This applies to<br />

the transparency and reflective lamps.<br />

• A lamp does not light up.


Lamp Replacement 93<br />

8.1.1 Replacing the Transparency Lamp<br />

The transparency fluorescent lamp is located inside the scanner's top<br />

cover.<br />

Light level is too low<br />

The following message window is displayed on the screen.<br />

To exit from the message window, perform one of the following:<br />

Click Abort; the scanner application quits. Replace the defective<br />

lamp (see the following instructions).<br />

Ø<br />

Ø<br />

Click Ignore, and continue with the pre-scan/scan. Replace the<br />

defective lamp when you have completed your work.<br />

Lamp does not light up<br />

The transparency lamps always light up a few seconds after the scanner<br />

is switched on.<br />

Ø<br />

Ø<br />

To confirm that a lamp needs replacing, switch the system off and<br />

on again.<br />

If the lamp does not light up after 15 seconds, replace the lamp and<br />

try again.


94 Chapter 8 Maintenance<br />

To replace a transparency lamp:<br />

1. Switch the scanner OFF.<br />

The transparency lamp is hot. Wait a few minutes for the lamp to<br />

cool off before replacing it.<br />

2. Lift up the top cover.<br />

Place a cardboard on the glass plate to prevent damaging the glass<br />

3.<br />

during this procedure.


Lamp Replacement 95<br />

Unscrew the four screws at the upper and lower corners of the top<br />

4.<br />

cover. After several rotations, the screws spring out of their<br />

sockets. There is no need to remove the screws.<br />

5. Close the top cover.<br />

Important: Make sure that the cover is closed properly. If the cover is not closed<br />

properly, it may suddenly spring open.


96 Chapter 8 Maintenance<br />

Remove the top cover by gripping it at two diagonal corners, and<br />

6.<br />

lifting it.<br />

After the top cover is removed, the transparency lamp is exposed.


Lamp Replacement 97<br />

Remove the transparency lamp in two steps. First, gently pull one<br />

7.<br />

end of the lamp inward:<br />

8. Then, lift out the other end:<br />

Insert a new transparency lamp. Make sure that you insert the lamp<br />

9.<br />

with the lamp window facing down.<br />

10. Place the top cover back in its proper position.


98 Chapter 8 Maintenance<br />

11. Open the top cover.<br />

12. Screw in the four screws at the upper corners of the lamp assembly.<br />

Switch ON the scanner, and verify that the new lamp illuminates<br />

13.<br />

after a few seconds.<br />

8.1.2 Replacing the Reflective Lamps<br />

The reflective lamps are located beneath the glass plate.<br />

Light level is too low<br />

The following message window is displayed on the screen.<br />

To exit from the message window, perform one of the following:<br />

Click Abort. The scanner application quits. Replace both lamps,<br />

according to the procedure outlined below.<br />

Ø<br />

Ø<br />

Click Ignore, and continue with the pre-scan/scan. Replace the<br />

lamps when you have completed your work.


Lamp Replacement 99<br />

To replace a reflective lamp:<br />

Switch ON the scanner.<br />

1.<br />

After a few seconds, the Status LED is green.<br />

2. Open the top cover.<br />

Press the Light button on the front panel for approximately<br />

3.<br />

5 seconds.<br />

The lamp assembly moves to the center of the glass plate.<br />

STATUS<br />

LIGHT<br />

4. Switch the scanner OFF.<br />

The reflective lamps are hot. Wait a few minutes for the lamps to cool off<br />

before replacing them.


100 Chapter 8 Maintenance<br />

Unscrew the four screws that fasten the glass plate to the scanner.<br />

5.<br />

The screws should be rotated 90° counterclockwise.<br />

Closed<br />

Open<br />

6. Lift the two handles of the glass plate.


Lamp Replacement 101<br />

7. Pull out the glass plate.<br />

8. Place the glass plate on a soft surface.


102 Chapter 8 Maintenance<br />

9. Remove the lamp in two steps. First, gently push the lamp inward.<br />

10. Then, lift the lamp out of the tray.


Lamp Replacement 103<br />

Insert a new lamp, making sure that the lamp window faces<br />

11.<br />

upwards and inwards.<br />

Reflective lamp<br />

alignment<br />

Always replace both reflective lamps, even if only one is faulty.<br />

Open<br />

Closed<br />

Lift the plate glass up (using the handles) and place it back in its<br />

12.<br />

original position (on the scanner frame).<br />

Screw in the four screws that fasten the glass plate to the scanner.<br />

13.<br />

The screws should be rotated 90°, clockwise.<br />

The correct closing position of the screws is shown in the<br />

illustration to the left.<br />

To check if the lamp replacement was successful, scan a trial<br />

14.<br />

picture in the Reflective mode.


104 Chapter 8 Maintenance<br />

8.2 Cleaning the Glass<br />

The upper and base glass plates require periodic cleaning. We<br />

recommend using domestic glass cleaning solution to clean all flat<br />

glass surfaces, as it leaves no trace after drying. The cleaning solution<br />

should not contain wax or ammonia. (Clear) Windex is recommended.<br />

Do not pour cleaning solution directly on the glass, as it may leak under the<br />

glass surfaces.<br />

Ø<br />

Wipe gently with a soft material or paper that does not leave a<br />

residue of fibers, such as rice paper or chamois leather.<br />

Ø<br />

When the glass is clean, use a soft brush or an air spray to dry the<br />

glass and remove dust.<br />

Use an anti-static cleaner to eliminate static charges.<br />

Ø


Cleaning the Glass 105<br />

8.2.1 Upper Glass Cleaning<br />

1. Switch OFF the main power switch of the scanner.<br />

The transparent lamp is hot. Wait a few minutes for the lamp to cool off<br />

before starting to clean the upper glass.<br />

2. Lift up the top cover.<br />

Place a cardboard on the glass plate to prevent damaging the glass<br />

3.<br />

during this procedure.


106 Chapter 8 Maintenance<br />

Unscrew the four screws at the upper and lower corners of the top<br />

4.<br />

cover. After several rotations, the screws spring out of their<br />

sockets. There is no need to remove the screws.<br />

5. Close the top cover.<br />

Important: Make sure that the cover is closed properly. If the cover is not closed<br />

properly, it may suddenly spring open.


Cleaning the Glass 107<br />

To avoid electric<br />

hazard while cleaning<br />

the upper glass, make<br />

sure to apply the<br />

cleaning solution only<br />

on the glass surface.<br />

Remove the top cover by gripping it at two diagonal corners, and<br />

6.<br />

lifting it.<br />

7. Clean the glass plate surface.


108 Chapter 8 Maintenance<br />

8.2.2 Base Glass Cleaning<br />

1. Switch OFF the main power switch of the scanner.<br />

The lamps in the lamp tray are hot. Wait a few minutes for the lamps to<br />

cool off.<br />

Unscrew the four screws that fasten the glass plate to the scanner.<br />

2.<br />

The screws should be rotated 90° counterclockwise.<br />

Closed<br />

Open


Cleaning the Glass 109<br />

3. Lift the two handles of the glass plate.<br />

4. Pull out the glass plate.


110 Chapter 8 Maintenance<br />

5. Place the glass plate on a soft surface.<br />

Clean the base glass surface, making sure you do not touch the<br />

6.<br />

white sticker running along the side of the glass.<br />

White Sticker<br />

After you clean the glass, grip the handles, and place the glass back<br />

7.<br />

in its original position. Tighten the four screws that secure the glass<br />

plate to the scanner.


111<br />

Chapter 9<br />

General<br />

Troubleshooting<br />

Power&Self-Tests........................... 113<br />

Scanning Quality. ............................ 115<br />

Scanner/Application Hangs. .................... 116<br />

lIluminationProblems......................... 117<br />

General SCSI Communication Problems .......... 117<br />

SCSI Communication Problems - Windows NT 4.0 . . 119


112 Chapter 9 General Troubleshooting<br />

This chapter describes some problems that may arise during scanning,<br />

and their solutions.<br />

• If the problem was solved, you can continue scanning.<br />

• If the problem remains, try the next suggestion.<br />

• If you have tried all the suggestions, and the problem persists,<br />

contact your service center.<br />

The service center may require information concerning your log<br />

folder, and the list of actions that you performed.<br />

<br />

For details on log files, refer to Appendix D Application Log Files on page 149.


Power & Self-Tests 113<br />

9.1 Power & Self-Tests<br />

Symptom<br />

• The Light and the Status LEDs on the operating panel do not light<br />

up.<br />

Suggestions<br />

Ø<br />

Ø<br />

Check power cable is connected correctly.<br />

Check the room's power supply.<br />

Symptom<br />

• The Status LED on the operating panel turns red.<br />

Suggestions<br />

Switch the scanner OFF, thenON. After 15 seconds, verify that<br />

Ø<br />

the Status LED is a constant green.<br />

Run the Scanner Checks procedure from the Installation &<br />

Ø<br />

Utilities application (refer to Section 7.3 Scanner Checks on<br />

page 78).<br />

On Macintosh platform, for an explanation of the Scanner Checks<br />

results file, refer to Section 7.6 <strong>EverSmart</strong> Scan Log Folder -<br />

Macintosh Computers on page 84.<br />

On PC platform, for an explanation of the Scanner Checks results<br />

file, refer to Section 7.7 Log Folders - Windows Operating System<br />

on page 85.<br />

If none of the suggested actions solve the problem, prepare the log<br />

folder, and contact your service center.<br />

Ø


114 Chapter 9 General Troubleshooting<br />

Symptom<br />

• The Status LED on the operating panel blinks red.<br />

Suggestions<br />

This event occurs when one of the scanner safety switches is activated.<br />

Switch the scanner OFF, thenON. After 15 seconds, verify that<br />

the Status LED is a constant green.<br />

Ø<br />

Ø<br />

Ø<br />

Ø<br />

Ø<br />

Check that the base glass is installed correctly.<br />

Check that the front panel is installed correctly.<br />

Check that the top cover is installed correctly.<br />

If none of the suggested actions solve the problem, contact your<br />

service center.


Scanning Quality 115<br />

9.2 Scanning Quality<br />

Symptoms<br />

• Vertical lines in the picture.<br />

• Unsharp picture.<br />

• Unfocused picture.<br />

• Shift in the crop.<br />

• Misregistration between channels.<br />

Suggestions<br />

Run the Scanner Check procedure from the Installation & Utilities<br />

application.<br />

Ø<br />

<br />

Refer to Section 7.3 Scanner Checks on page 78 for more information on<br />

the Scanner Check procedure.<br />

Ø<br />

Ø<br />

Ø<br />

Ø<br />

Verify that all the tests pass.<br />

Run the Create Tables procedure from the Installation & Utilities<br />

application.<br />

<br />

For details, refer to Section 7.4 Create Tables on page 80.<br />

Perform a scan, and compare the results with the defective scan.<br />

If none of the suggested actions solves the problem, prepare the log<br />

folder, and contact your service center.


116 Chapter 9 General Troubleshooting<br />

Symptoms<br />

• Jagged lines.<br />

• Horizontal lines.<br />

Suggestions<br />

Verify that the four base screws are tightly closed (refer to the<br />

figure in Section 8.2.2 Base Glass Cleaning on page 108).<br />

Ø<br />

Ø<br />

Ø<br />

Make sure that the original is placed on the base glass according to<br />

one of the following:<br />

• The original is taped directly onto the base glass.<br />

• The original is taped onto a mask that is placed on the<br />

registration pins.<br />

Run the Scanner Check procedure from the Installation & Utilities<br />

application (refer to Section 7.3 Scanner Checks on page 78, orto<br />

Section On PC platform, for an explanation of this file, refer to<br />

Section 7.7 Log Folders - Windows Operating System on page 85.<br />

on page 79). Verify that all the tests pass.<br />

9.3 Scanner/Application Hangs<br />

Symptoms<br />

• Scanner application hangs.<br />

• Warning messages are displayed.<br />

Suggestions<br />

Restart the computer.<br />

Ø<br />

Switch the scanner OFF, andthenON. After 15 seconds, verify<br />

Ø<br />

that the Status LED is a constant green.<br />

If the Status LED remains red, call your service center.<br />

Ø<br />

Check SCSI communication (for Macintosh platform, refer to<br />

Section 9.5 on page 117; for PC platform, refer to Section 9.6 on<br />

page 119).


lIlumination Problems 117<br />

Ø<br />

Ø<br />

Ø<br />

Run the Scanner Checks procedure from the Installation &<br />

Utilities application (refer to Section 7.3 Scanner Checks on<br />

page 78).<br />

On Macintosh platform, for an explanation of the Scanner Checks<br />

results file, refer to Section 7.6 <strong>EverSmart</strong> Scan Log Folder -<br />

Macintosh Computers on page 84.<br />

On PC platform, for an explanation of the Scanner Checks results<br />

file, refer to Section 7.7 Log Folders - Windows Operating System<br />

on page 85. Verify that all the tests pass.<br />

Restart your computer without the extensions. Choose Restart<br />

from the Special menu, and hold down the Shift key while the<br />

computer is booting. Try to scan the image again.(MAC only.)<br />

If none of the suggested actions solve the problem, prepare the log<br />

folder, and contact your service center.<br />

9.4 lIlumination Problems<br />

Symptom<br />

• Low light level message is displayed.<br />

Suggestion<br />

Refer to Lamp Replacement on page 92.<br />

Ø<br />

9.5 General SCSI Communication Problems<br />

Symptoms<br />

• Message appears saying that there is a communication problem<br />

("No communication with scanner. Turn scanner ON and check<br />

SCSI connections").<br />

• The scanner does not appear in the SCSI chain in the SCSI<br />

Information panel.<br />

Suggestions<br />

Ø<br />

Ø<br />

Switch the scanner OFF, thenON. After 15 seconds, verify that<br />

the Status LED is a constant green.<br />

If the Status LED remains red, call your service center.


118 Chapter 9 General Troubleshooting<br />

Ø<br />

Ø<br />

Ø<br />

Ø<br />

Check that all cables are correctly connected, and that the SCSI<br />

chain is no longer than 6 meters.<br />

Make sure that a terminator is connected to the last device on the<br />

SCSI chain. If the scanner is the last device, make sure that the<br />

scanner terminator switch is set to ON.<br />

Check that two devices have not been given the same ID number.<br />

Activate the SCSI Information application. Check if the scanner<br />

appears in the SCSI chain (Macintosh platform only).<br />

<br />

For PC platform, refer to Section 9.6 SCSI Communication Problems -<br />

Windows NT 4.0 on page 119.


PC<br />

SCSI Communication Problems - Windows NT 4.0 119<br />

9.6 SCSI Communication Problems - Windows NT 4.0<br />

Before performing any of the following troubleshooting procedures, consult the<br />

Administrator.<br />

To verify that the driver for your SCSI host adapter is installed:<br />

1. Click the Start button, point to Settings, thenclickControl Panel.<br />

Double-click SCSI Adapters. If the driver is properly installed,<br />

2.<br />

your host adapter is displayed in the SCSI Adapters window.<br />

To check that the SCSI devices are installed:<br />

Turn ON the scanner, and confirm that the two LEDs on the<br />

1.<br />

Operating panel are green.<br />

2. Restart your computer.<br />

Click the Start button, point to Settings, andthenclickControl<br />

3.<br />

Panel.<br />

4. Double-click SCSI Adapters.


PC<br />

120 Chapter 9 General Troubleshooting<br />

In the SCSI Adapters window, double-click the host adapter to see<br />

5.<br />

which devices are connected to it.<br />

The scanner should appear in the list. If not, check the SCSI ID,<br />

6.<br />

the SCSI cable, and the termination. Refer to<br />

Section 5.3 Connecting Options on page 45.<br />

To check the SCSI ID:<br />

1. Click the Start button, point to Settings, thenclickControl Panel.<br />

2. Double-click SCSI Adapters.


PC<br />

SCSI Communication Problems - Windows NT 4.0 121<br />

Double-click Scitex <strong>EverSmart</strong> <strong>Jazz</strong>; the following window is<br />

3.<br />

displayed.<br />

4. Click the Settings tab to open the following panel.<br />

Check that the Target ID is identical to the SCSI ID on the SCSI<br />

5.<br />

selector on the back of the scanner. Also, chesk that each device<br />

has a unique SCSI ID.


PC<br />

122 Chapter 9 General Troubleshooting<br />

To check which resources your SCSI host adapter is using:<br />

1. Click Start, pointtoSettings, and then click Control Panel.<br />

2. Double-click SCSI Adapters.<br />

In the SCSI Adapters window, click the Properties; the following<br />

3.<br />

window is displayed.<br />

4. Check which resources are in use.


PC<br />

SCSI Communication Problems - Windows NT 4.0 123<br />

To check which resources are available in your computer:<br />

Click the Start button, point to Programs,thentoAdministrative<br />

1.<br />

Tools,thenclickWindows NT Diagnostics.<br />

In the Windows NT Diagnostics window, click the Resources tab to<br />

2.<br />

see which resources are available.


PC<br />

124 Chapter 9 General Troubleshooting<br />

Make sure the host adapter driver aic78xx is displayed on the<br />

3.<br />

Device list. Then, click Devices; the following window is<br />

displayed.<br />

The host adapter<br />

driver used in your<br />

scanner is Aic78xx.<br />

4. Click OK to close the window.<br />

To check that your SCSI device drivers are working properly:<br />

1. Click the Start button, point to Settings, thenclickControl Panel.<br />

2. In the Control Panel window, double-click Devices.<br />

In the Devices window, the host adapter driver should indicate<br />

3.<br />

Started under the Status column, and Boot in the Startup column,<br />

such as the host adapter driver selected in the above figure.


SCSI Communication Problems - Windows NT 4.0 125<br />

The following table provides a list of host adapter drivers that may be<br />

listed in the Devices window.<br />

The host adapter<br />

driver used in your<br />

scanner is Aic78xx.<br />

Host Adapter Driver<br />

Sparrow<br />

Arrow<br />

T358<br />

T348<br />

Aic78xx<br />

Aic78u2<br />

Aic78u2<br />

Aha154x<br />

Aha174x<br />

Fd16_700<br />

Host Adapter Family<br />

Adaptec 150x/151x/AIC6260/6360/<br />

6365/6370<br />

Adaptec 274x/284x/AIC-777x<br />

Adaptec APA-358 MiniSCSI EPP<br />

Adaptec APA-348 MiniSCSI Plus<br />

Adaptec AHA-290x/291x/294x/<br />

394x/4944 or AIC-78xx PCI SCSI<br />

Controller (NT 4.0)<br />

Adaptec AHA-294xU2W/<br />

295xU2W/<br />

AIC-789x PCI Ultra2 SCSI<br />

Controller (NT 3.5x)<br />

Adaptec AHA-294xU2W/<br />

295xU2W/<br />

AIC-789x PCI Ultra2 SCSI<br />

Controller (NT 4.0)<br />

Adaptec AHA-154x/1647x/1535<br />

Adaptec AHA-174x (Enhanced<br />

Mode)<br />

Adaptec AHA-2920 (PCI)<br />

If there is still no SCSI communication, it is recommended to reload the SCSI<br />

driver. Before relaoding, please consult your system administrator.


127<br />

Appendix A<br />

Packing the<br />

Scanner<br />

Locking the Scanner ..........................128<br />

Packing the Scanner. .........................131


128 Packing the Scanner<br />

This appendix provides instructions on how to pack the scanner when<br />

it is necessary to transport it from one location to another.<br />

A.1 Locking the Scanner<br />

1. Switch the scanner OFF.<br />

Press the SCSI selector on the back of the scanner to position<br />

2.<br />

number 8.<br />

Switch the scanner ON, and wait 15 seconds until the Status LED<br />

3.<br />

is a constant green.


Locking the Scanner 129<br />

Press the Light button on the operator panel, and wait 5 seconds for<br />

4.<br />

the carriage to move to the locking position, on the right side of the<br />

scanner.<br />

STATUS<br />

LIGHT<br />

Insert the flat screw driver in the niche of the screw located at the<br />

5.<br />

inside upper right corner of the top cover, push the screw inward,<br />

and turn the screw once, counter-clockwise.<br />

Unlock<br />

Lock


130 Packing the Scanner<br />

Insert the flat screwdriver in the niche of the screw located on the<br />

6.<br />

right hinge of the top cover, and turn the screw once, clockwise.<br />

Unlock<br />

Lock


Packing the Scanner 131<br />

A.2 Packing the Scanner<br />

Place the accessory packages (installation kit, masks, <strong>EverSmart</strong><br />

1.<br />

Training kit) on the wooden palette.


132 Packing the Scanner<br />

Find the holding niche beneath the frame of the scanner (lengthwise),<br />

carefully lift the scanner, and place it on the wooden palette.<br />

2.<br />

Make sure to place the scanner on the four bumpers located at the<br />

four corners of the palette, and according to the markings on the<br />

bumpers.<br />

Remember, the scanner weighs approximately 70 kg (156 lb), and two people<br />

are required to lift it up.


Packing the Scanner 133<br />

3. Place the carton carefully over the scanner.<br />

4. Insert the four foam corners in the space between the scanner<br />

corners and the outer carton (these are required to prevent<br />

movement of the scanner).


134 Packing the Scanner<br />

5. Place the upper cover protecting the scanner.<br />

6. Close the top cover and tape the carton.<br />

7. Use straps to attach the wooden palette to the carton.


135<br />

Appendix B<br />

Technical<br />

Specifications


136 Technical Specifications<br />

TECHNOLOGY<br />

Scanning System<br />

Image Sensor<br />

Illumination<br />

Sampling Accuracy<br />

Max Density<br />

Optic Resolution (over the<br />

Entire Scanner Format)<br />

Auto Focus Range<br />

INPUT<br />

Scanning Area<br />

Original Types<br />

Maximum Original Thickness<br />

OUTPUT<br />

Scaling (at 300 DPI)<br />

Scaling Steps 0.1%<br />

Flatbed scanner with moving scan head<br />

over entire scan area (fixed scan glass)<br />

Tri-Linear color CCD - 3 x 8000 pixels<br />

Fluorescent lamps<br />

14 bits / pixel<br />

3.7 D Max<br />

Supported File Formats - Mac Platform<br />

2000 DPI/79 DPM - <strong>EverSmart</strong> <strong>Jazz</strong><br />

2540 DPI/100 DPM - <strong>EverSmart</strong> <strong>Jazz</strong>+<br />

Fromglassupto5mm<br />

305x432mm/12x17in.<br />

Transparent (positive and negative),<br />

reflective, framed slide, lineart, printed<br />

material<br />

Transparent: 5 mm / 3/16 in.<br />

Reflective: Unlimited<br />

20-2000% for any original size<br />

(<strong>EverSmart</strong> <strong>Jazz</strong>)<br />

20-2500% for any original size<br />

(<strong>EverSmart</strong> <strong>Jazz</strong>+)<br />

Scitex: Scitex CT, Scitex LW, Scitex<br />

PSImage<br />

EPSF: Normal, DCS, ICS, RGB, CMYK,<br />

Gray scale and Bitmap<br />

TIFF: RGB, CMYK, CMY, Gray scale<br />

and Bitmap<br />

PICT: RGB, Gray scale and Bitmap<br />

Adobe PhotoShop: CMYK, RGB


137<br />

Supported File Formats - PC Platform<br />

FEATURES<br />

INTERFACE<br />

EPS, TIFF, Scitex CT<br />

Autofocus on picture<br />

Batch scanning<br />

Registration pins<br />

SCSI<br />

ELECTRICAL REQUIREMENTS<br />

Input Power Voltage<br />

100 - 240 VAC, 50/60 Hz - voltage<br />

selection is automatic<br />

Power Consumption<br />

Dimensions (HxWxD)<br />

Weight<br />

ENVIRONMENT<br />

Operating Temperature<br />

Storage Temperature<br />

Humidity<br />

Acoustic Noise Level<br />

APPROVAL<br />

290 W - operation<br />

200 W - standby<br />

36 x 87x 62 cm / 14 x 34.2 x 24.4 in.<br />

70 kg / 156 lb<br />

16 - 27 °C /61-80°F<br />

-10 - 55°C /14-131°F<br />

40-70% non-condensing<br />

< 55 dBA - operation<br />

< 50 dBA - standby<br />

UL, CUL, CE, ISO 9002


139<br />

Appendix C<br />

Documentation<br />

Folder<br />

MacDocumentationFolder.....................140<br />

Windows Documentation Folder .................145


MAC<br />

140 Documentation Folder<br />

C.1 Mac Documentation Folder<br />

This appendix lists the contents of the Documentation folder located on<br />

the <strong>EverSmart</strong> <strong>Jazz</strong> application CD-ROM. The documents are in<br />

Adobe Acrobat PDF file format, so you need to install Adobe Acrobat<br />

Reader version 3. Installation instructions are included in this<br />

appendix.<br />

The contents of this appendix appear in the Readme file located in the above<br />

Documents folder.


MAC<br />

Mac Documentation Folder 141<br />

The <strong>EverSmart</strong> Doc folder contains the following subfolders:<br />

• <strong>EverSmart</strong> <strong>Jazz</strong><br />

• <strong>EverSmart</strong> <strong>Scanners</strong>


MAC<br />

142 Documentation Folder<br />

The <strong>EverSmart</strong> <strong>Jazz</strong> folder contains the following files and subfolders:<br />

System Requirements<br />

• The Readme file (in three languages) contains general information<br />

about installation procedure, system requirements, etc.<br />

• The PDF folder contains all the manuals in PDF format.<br />

• The Reader folder contains the Acrobat Reader and the Search<br />

Installers.<br />

The manuals are in Adobe Acrobat PDF file format. In order to view or<br />

print these files you must have the Adobe Acrobat Reader installed.<br />

Installation instructions are provided below.<br />

Adobe Acrobat Reader with Search for Macintosh and Power<br />

Macintosh<br />

Minimum Requirements:<br />

• Macintosh with a 68020 or greater processor, or Power Macintosh<br />

• 3.5 MB of RAM (5 MB for Power Macintosh) available to Acrobat<br />

Reader<br />

• MacOS version 7.0 or later


MAC<br />

Mac Documentation Folder 143<br />

Recommended Requirements:<br />

• 8 MB of available RAM<br />

• MacOS version 7.1.2 or later<br />

• 12.5 MB of available hard-disk space<br />

Installing Adobe Acrobat Reader on your computer<br />

To install Acrobat Reader 3.0 on your hard disk drive:<br />

Run the Install Acrobat Reader 3.0 program located in the<br />

Ø<br />

<strong>EverSmart</strong> Documentation\Reader\Reader folder.<br />

You will have to Restart your computer once the Installation is completed.<br />

The manuals in PDF format can be read on a PC with Windows NT, Windows<br />

95, Windows 3.1 or Windows 3.11, using Adobe Acrobat Reader 3.0. If you do<br />

not have this Acrobat version on your PC, you can download it from the Adobe<br />

web site.<br />

To use Adobe Acrobat Search Function:<br />

1. In Adobe Acrobat Reader 3.0, select Search from the Tools menu.<br />

The first time you use the search index, you will need to add the<br />

2.<br />

<strong>EverSmart</strong> <strong>Jazz</strong> to the index list. To do so, select Indexes.<br />

3. Select Add.<br />

4. Select the index.pdx file on the CD-ROM drive.<br />

5. Click OK.<br />

To search for a topic, select Search from the Tools menu. In the<br />

6.<br />

Search window, select Query.<br />

Type the text you would like to search for in the Find Results<br />

7.<br />

Containing box.<br />

8. Click Search.<br />

The Search Results window appears, containing a list of books<br />

9.<br />

where your word was found. Select which book you want to look<br />

at first, and click View.


MAC<br />

144 Documentation Folder<br />

The PDF file opens with all the occurrences of the search text<br />

10.<br />

highlighted. Use the command-U keys to navigate between the<br />

hits.<br />

For more information see the On-line Guide to Acrobat Adobe Search<br />

provided on the CD-ROM.<br />

If your Adobe Acrobat Reader does not include a Search function, install the<br />

Adobe Acrobat Reader provided on this CD-ROM.


PC<br />

Windows Documentation Folder 145<br />

C.2 Windows Documentation Folder<br />

This appendix lists the contents of the Documentation folder located on<br />

the <strong>EverSmart</strong> <strong>Jazz</strong> application CD-ROM. The documents are in<br />

Adobe Acrobat PDF file format, so you need to install Adobe Acrobat<br />

Reader version 3. Installation instructions are included in this<br />

appendix.


PC<br />

146 Documentation Folder<br />

The Release Documents folder contains the following .pdf files.<br />

• Adaptec 2903B/2906 SCSI Host Adapter Installation Guide - PC<br />

Platform.pdf<br />

• <strong>EverSmart</strong> <strong>Jazz</strong> for Windows Release Notes.pdf<br />

• <strong>EverSmart</strong> <strong>Jazz</strong> User Guide.pdf (English)<br />

• <strong>Jazz</strong> Installation and Maintenance Guide.pdf (English)


PC<br />

Windows Documentation Folder 147<br />

The manuals are in Adobe Acrobat PDF file format. In order to view or<br />

print these files you must have the Adobe Acrobat Reader installed.<br />

Installation instructions are provided below.<br />

System Requirements for Installing Adobe Acrobat Reader:<br />

• x86-based personal computer (386 minimum; 486, Pentium, or<br />

Pentium Pro recommended)<br />

• Microsoft Windows 3.1, Microsoft Windows for Workgroups,<br />

Microsoft Windows 95, Microsoft Windows NT 3.51 or 4.0<br />

• 4 MB application RAM<br />

• 5 MB hard disk space, plus 7 MB additional temporary disk space<br />

available during installation<br />

• For viewing PDF files inside of a Web browser:<br />

Netscape Navigator 3.0 or later (3.0.1 or later recommended)<br />

or Microsoft Internet Explorer 3.0 or later.


PC<br />

148 Documentation Folder<br />

Installing Adobe Acrobat Reader on your computer<br />

To install Acrobat Reader 3.0 on your hard disk drive:<br />

Insert the Scitex Software application CD-ROM into the CD-ROM<br />

1.<br />

drive; the Scanner Setup window is displayed.<br />

2. Click Install Acrobat PDF Reader to start the installation process.<br />

You will have to Restart your computer once the Installation is completed.<br />

The manuals in PDF format can be read on a PC with Windows NT, Windows<br />

95, Windows 3.1 or Windows 3.11, using Adobe Acrobat Reader 3.0. If you do<br />

not have this Acrobat version on your PC, you can download it from the Adobe<br />

web site.<br />

3. Restart your computer.


149<br />

Appendix D<br />

Application Log<br />

Files<br />

MacintoshApplicationLogFiles.................150<br />

Windows Application Log Files ..................151


MAC<br />

150 Application Log Files<br />

D.1 Macintosh Application Log Files<br />

If you encounter any problems in quality issues, you may be requested<br />

to provide the log file created by the application for a thorough<br />

examination by a specialist in your local service center.<br />

To create application log files:<br />

In the scanner application, from the Setup menu, select Files under<br />

1.<br />

General Preferences. TheFiles Preferences dialog box opens.<br />

2. Select the Create Scanner Driver Log File option, and click OK.<br />

3. Continue scanning.<br />

After the final scan, the application log files will be created in the <strong>EverSmart</strong><br />

Scan _Log Folder.<br />

Send the created <strong>EverSmart</strong> Scan _Log files to your service center.<br />

Every time you enter the scanning application, existing application log files are<br />

erased and new application log files are created instead.<br />

Important: If the scanner application problem was solved, it is recommended<br />

you clear the Create Scanner Driver Log File option in the Files Preferences<br />

dialog box.


PC<br />

Windows Application Log Files 151<br />

D.2 Windows Application Log Files<br />

If you encounter any problems in quality issues, you may be requested<br />

to provide the log file created by the application for a thorough<br />

examination by a specialist in your local service center.<br />

To create application log files:<br />

In the scanner application, from the Setup menu, select General<br />

1.<br />

PreferencesàFiles;theGeneral Preferences window opens.<br />

2. Click the Files tab.<br />

3. Select the Create General Log File option, and click OK.<br />

4. Continue scanning.<br />

After the final scan, the application log files will be created in the <strong>EverSmart</strong><br />

Scan _Log files.<br />

Send the created <strong>EverSmart</strong> Scan _Log files to your service center.<br />

Every time you enter the scanning application, existing application log files are<br />

erased and new application log files are created instead.<br />

Important: If the scanner application problem was solved, it is recommended<br />

you clear the Create Scanner Driver Log File option in the General Preferences<br />

window.


153<br />

Appendix E<br />

Catalog Numbers


154 Catalog Numbers<br />

(<br />

Installation Kit<br />

includes:<br />

Part Name<br />

Catalog No.<br />

510K51103<br />

• SCSI Interface Board - Adaptec 2903 or compatible 605B00660<br />

• Power cable, 3 m (American Cord) 199A03110<br />

• SCSI cable, 2 m (C50M/DB25M) 199D20106B<br />

• Installation & Maintenance Guide package 501L52949A<br />

(includes the following items:)<br />

• English (Mac, PC) 399Z52780B<br />

• French (Mac) 399Z1M556A<br />

• German (Mac) 399Z1M555A<br />

• Calibration slide package type II 509D1L014A<br />

• Scanner software CD-ROM (Mac) 501V52959<br />

• Scanner software CD-ROM (PC) 501V52956<br />

• Screwdriver 395A10015<br />

Mask pack 35 mm, framed (1 piece)<br />

Mask pack, User defined (10 pieces)<br />

Mask pack, Mix format (5 pieces)<br />

Mask pack, 35 mm strip (5 pieces)<br />

509D1L294<br />

509D1L005<br />

509D1L517<br />

509D1L495<br />

Lamp<br />

Scanning lamp (1 piece)<br />

139H15005


155<br />

Part Name<br />

<strong>EverSmart</strong> <strong>Jazz</strong> Training Kit<br />

Catalog No.<br />

513K1M974A<br />

includes<br />

• User Guide (English; Mac) 399Z52678A<br />

• User Guide (English; PC) 399Z52691A<br />

• Image Correction Examples 399Z50389A<br />

• Computer Based Application Training CD-ROM<br />

(Mac)<br />

• English<br />

• French<br />

• German<br />

501V50762B<br />

501V50763B<br />

501V50764B<br />

• Final Touch CD-ROM (Mac) 501V51206A<br />

Oil Mounting Kit (optional)<br />

501R44937<br />

Bulleted items are included in their respective kits.<br />

The letter in the end of the catalog number stands for a version. When you<br />

order a software application or a book, you should make sure you are ordering<br />

the latest version.


<strong>EverSmart</strong> <strong>Jazz</strong> <strong>Scanners</strong> Installation and Maintenance - Mac and PC Platforms 157<br />

Index<br />

Numerics<br />

25 pin SCSI connector, 39<br />

50 pin SCSI connector, 39<br />

A<br />

Acoustic noise level, 137<br />

Acrobat Reader Search, using, 143<br />

Acrobat Reader, installing, 143, 148<br />

Adaptec SCSI card, 50<br />

Administrator, log on as, 29, 52<br />

Aligning<br />

reflective lamp, 103<br />

Aligning, reflective lamp, 103<br />

Application log files<br />

Macintosh, 150<br />

Windows, 151<br />

Approval, international standards, 137<br />

Auto focus range, 136<br />

Automatic diagnostics check, 59<br />

Automatic optics check, 60<br />

B<br />

Backup media, parameters, 62<br />

Base glass, cleaning, 57, 104, 108<br />

Board, installation, 41<br />

C<br />

Cable<br />

power, 154<br />

SCSI, 3, 154<br />

Calibration slide, 12, 154<br />

incorrectly placed, 70<br />

CD, software, 24, 29<br />

Cleaning<br />

base glass, 57, 104, 108<br />

glass plates, 57<br />

kit, 12<br />

upper glass, 105<br />

Communication problems<br />

SCSI, general, 117<br />

SCSI, Windows NT, 119<br />

Configuration options, 37<br />

Connecting options, 45<br />

Connector<br />

SCSI, location, 38<br />

sockets, 39<br />

Create tables<br />

utility, 80<br />

window, 61<br />

Creating<br />

log file, Macintosh, 150<br />

log file, Windows, 151<br />

Custom Install, 76<br />

D<br />

Devices, host adapter drivers, 125<br />

Diagnostics, 34<br />

system requirements, 87<br />

tests, 88<br />

Diagnostics application<br />

launching, 89<br />

quitting, 89<br />

running, 88<br />

running in loop, 89<br />

Diagnostics check, 53, 59<br />

error, 79<br />

failure, 69<br />

Dimensions, scanner, 2, 137<br />

Documentation folder<br />

Macintosh, 140<br />

Windows, 145<br />

Driver, SCSI installing, 48<br />

E<br />

Electrical requirements, 137<br />

Error<br />

diagnostics check, 79<br />

optics check, 79


158 Index<br />

<strong>EverSmart</strong> Install&Utils, 28, 34<br />

icon, 52, 76<br />

launching application, 52<br />

<strong>EverSmart</strong> <strong>Jazz</strong><br />

application folder, 28, 34<br />

installation kit, 12<br />

software application CD, 24, 29<br />

system requirements, 4<br />

<strong>EverSmart</strong> <strong>Jazz</strong> folder, contents, 142<br />

<strong>EverSmart</strong> <strong>Jazz</strong> training kit, 155<br />

<strong>EverSmart</strong> <strong>Jazz</strong>Tables, 34<br />

<strong>EverSmart</strong> Scan 2.5.1 Installer window, 25<br />

<strong>EverSmart</strong> Service Diagnostics window, 88<br />

<strong>EverSmart</strong>Scan.Prefs file, 54, 61<br />

Exit<br />

Diagnostics application, 89<br />

installation, 64<br />

F<br />

File formats<br />

Macintosh computers, 136<br />

Macintosh platform, 136<br />

PC platform, 137<br />

Full installation, 52<br />

G<br />

General tips, 64<br />

H<br />

Host adapter drivers, 125<br />

Humidity, 2, 137<br />

I<br />

ID<br />

SCSI, selector, 40<br />

SCSI, setting, 49<br />

Illumination, 136<br />

problems, 117<br />

Image sensor, 136<br />

Install&Util_Log File, 85<br />

Install&Util_results file, 64, 77, 85<br />

Installation<br />

board, SCSI, 41<br />

custom, 76<br />

Internet Explorer, 87<br />

kit, 12, 154<br />

procedure, start, 53<br />

quitting, 64<br />

results, 64<br />

SCSI driver, 48<br />

stage options, 53<br />

stages, 77<br />

Installation Wizard, 29<br />

Installing, Acrobat Reader, 143, 148<br />

Internet Explorer, installing, 87<br />

J<br />

JServer folder, 86<br />

K<br />

Kit<br />

cleaning, 12<br />

<strong>EverSmart</strong> training, 155<br />

installation, 12, 154<br />

mask, 13, 154<br />

oil mounting, 155<br />

L<br />

Lamp<br />

power & selt-tests, 113<br />

replacement, 92<br />

Location<br />

scanner, 3<br />

SCSI connector, 38<br />

Locking scanner, 128<br />

Log file<br />

accessing, 85, 150, 151<br />

creating, Macintosh, 150<br />

creating, Windows, 151<br />

Log folder<br />

<strong>EverSmart</strong> Scan, 84, 85<br />

Jserver, 86<br />

results, 64<br />

Log on, administrator, 52


<strong>EverSmart</strong> <strong>Jazz</strong> <strong>Scanners</strong> Installation and Maintenance - Mac and PC Platforms 159<br />

M<br />

Mask kit, 13, 154<br />

MatchBuilder, 28<br />

Max density, 136<br />

Maximum original thickness, 136<br />

Media, backup, 62<br />

Minimum requirements, 4, 5<br />

O<br />

Oil Mounting kit, 155<br />

Optic resolution, 136<br />

Optics check, 60<br />

error, 79<br />

out of tolerance, 71<br />

Original types, 136<br />

Out of Tolerance, 60<br />

P<br />

Packing scanner, 131<br />

Parameters, saving, 62<br />

Partial installation, 76<br />

PCI expansion slot, 42<br />

Pin holes, 58<br />

Power<br />

cable, 154<br />

consumption, 2, 137<br />

Powering on, 18<br />

Procedure, full installation, 52<br />

R<br />

Reflective lamp<br />

aligning, 103<br />

replacemnent, 98<br />

Release Documents folder, 34<br />

contents, 146<br />

Removing packing, 14<br />

Replacing<br />

reflective lamp, 98<br />

transparency lamp, 93<br />

Requirements<br />

Adobe Acrobat Reader, 142, 147<br />

system, 4, 5<br />

Resolution, optic, 136<br />

Resources, troubleshooting, 123<br />

Results<br />

diagnostics check, 59<br />

diagnostics test, 90<br />

optics check, 60<br />

Results file, 77, 79, 81, 83<br />

S<br />

Safety instructions, 6<br />

Sampling accuracy, 136<br />

Saving, parameters, 62, 83<br />

Scaling, 136<br />

Scanner<br />

CD, 12<br />

checks, Macintosh computers, 78<br />

connecting options, 45<br />

dimensions, 2, 137<br />

folder, 30<br />

location, 3<br />

locking, 128<br />

packing, 131<br />

parameters, 54, 61<br />

powering on, 18<br />

preparing, 57<br />

software, 154<br />

unpacking, 8<br />

Scanner Check log file, 85<br />

Scanner Setup window, 29<br />

Scanner/application hangs, 116<br />

Scanning<br />

area, 136<br />

quality, troubleshooting, 115<br />

system, 136<br />

Scitex SCSI Information, 28


160 Index<br />

SCSI<br />

adapter resources,troubleshooting, 122<br />

board installation, 41<br />

bus, 50<br />

cable, 3, 12, 37, 154<br />

communication problems, Windows NT, 119<br />

connector location, 38<br />

device drivers, troubleshooting, 124<br />

devices, troubleshooting, 119<br />

driver installation, 48<br />

general communication problems, 117<br />

host adapter, troubleshooting, 119<br />

ID selector, 40<br />

ID, setting, 49<br />

ID,troubleshooting, 120<br />

interface board, 12, 154<br />

SCSI communication failure, 68<br />

Serial number<br />

entering, 54<br />

location, 55, 56<br />

Serial number mismatch, 66, 67<br />

Setting<br />

SCSI ID, 49<br />

Shipping package, 2<br />

Site preparation, 2<br />

Software<br />

application CD, 24, 29<br />

CD, scanner, 12<br />

Startup<br />

sequence, 20<br />

troubleshooting, 21<br />

Startup process, in Diagnostics, 88<br />

Status screen, 75<br />

Storage temperature, 137<br />

System requirements<br />

Adobe Acrobat Reader, 142, 147<br />

for running Diagnostics, 87<br />

T<br />

Temperature<br />

operating, 2, 137<br />

Terminator switch, 40<br />

Thickness, maximum original, 136<br />

Training package, 13<br />

Transparency lamp, replacement, 93<br />

Troubleshooting<br />

adapter resources, 122<br />

available resources, 123<br />

calibration slide incorrectly placed, 70<br />

diagnostics check failure, 69<br />

illumination problems, 117<br />

lamp, power & self tests, 113<br />

optics check out of tolerance, 71<br />

scanner/application hangs, 116<br />

scanning quality, 115<br />

SCSI ID, 120<br />

serial number mismatch, 66, 67<br />

startup, 21<br />

wrong meadia inserted, 67<br />

Troubleshooting, SCSI<br />

communication failure, 68<br />

communication problems, Windows NT, 119<br />

device drivers, 124<br />

devices, installation, 119<br />

general communication problems, 117<br />

host adapter driver, installation, 119<br />

U<br />

Unlocking instructions, 14<br />

Unpacking scanner, 8<br />

Upper glass, cleaning, 57, 104, 105<br />

V<br />

Voltage, 2, 18, 137<br />

W<br />

Warning messages<br />

lamp not lit, 93<br />

low light level, 93, 98<br />

Weight, 2, 137<br />

Wrong media inserted, 67

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!