04.06.2015 Views

ASA 0929 230/460V (60Hz) (3 HP) - Federal Fluid Power, Inc.

ASA 0929 230/460V (60Hz) (3 HP) - Federal Fluid Power, Inc.

ASA 0929 230/460V (60Hz) (3 HP) - Federal Fluid Power, Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ASA</strong> <strong>0929</strong> <strong>230</strong>/<strong>460V</strong> (<strong>60Hz</strong>) (3 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: 28 in<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

92.570<br />

65.000<br />

74.056<br />

52.000<br />

55.542<br />

39.000<br />

37.028<br />

26.000<br />

18.514<br />

13.000<br />

40 80 120 160<br />

Qp [GPM]<br />

40 80 120 160<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong><strong>0929</strong>SA6C 3 <strong>HP</strong> 4.8 A IP 55 1200 RPM 8500 SCFM 91 db(A) 384.12 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> <strong>0929</strong> <strong>230</strong>/<strong>460V</strong> (<strong>60Hz</strong>) (7.5 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: 32 in<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

116.110<br />

65.000<br />

92.888<br />

52.000<br />

69.666<br />

39.000<br />

46.444<br />

26.000<br />

23.222<br />

13.000<br />

40 80 120 160<br />

Qp [GPM]<br />

40 80 120 160<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong><strong>0929</strong>SA6F 7.5 <strong>HP</strong> 11 A IP 55 1175 RPM 11450 SCFM 94 db(A) 468.16 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


*Note – Cooling Performance<br />

The cooling performance mentioned in this homepage is conservative and measured at a test bench according to asa test procedures<br />

with oil type ISO VG 46 and presents a bases for your cooler selection regarding required cooling performance. Because there is no<br />

standard test procedure, tests used by other manufacturers might have different results. Due to different environment conditions the<br />

cooling performance can vary by +/- 15%.<br />

Therefore we recommend all coolers be checked under the system operating conditions. This is also true for vibrations and mechanical<br />

stress as well as for pressure peaks and thermal stress.<br />

General tolerance according to DIN 2768-g.<br />

The information contained in this homepage is intended to be used as a guideline only. Customers should always confirm the suitability<br />

of the information and these products in their particular applications. <strong>ASA</strong> assumes no liability for any errors, commissions or misprints<br />

and reserves the right to change products and details without prior notification.As we are constantly improving our products, the<br />

characteristics, dimensions and weights can also change, although we do our best to incorporate these changes continually.<br />

asa hydraulik of America <strong>Inc</strong>.<br />

160 Meister Avenue #20A<br />

Branchburg, NJ 08876<br />

Tel.: 800-473-9400<br />

Fax: 908-541-1550<br />

sales_US@asahydraulik.com<br />

www.asahydraulik.com<br />

Copyright 2008 asa hydraulik GmbH


TT 01 115V AC (0.03 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: -<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

0.380<br />

8.700<br />

0.304<br />

6.960<br />

0.228<br />

5.220<br />

0.152<br />

3.480<br />

0.076<br />

1.740<br />

1 3 4 5<br />

Qp [GPM]<br />

1 3 4 5<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0013UE03 0.03 <strong>HP</strong> 0.12 A IP 20 2650 RPM 70.6 SCFM 41 db(A) 3.08 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


*Note – Cooling Performance<br />

The cooling performance mentioned in this homepage is conservative and measured at a test bench according to asa test procedures<br />

with oil type ISO VG 46 and presents a bases for your cooler selection regarding required cooling performance. Because there is no<br />

standard test procedure, tests used by other manufacturers might have different results. Due to different environment conditions the<br />

cooling performance can vary by +/- 15%.<br />

Therefore we recommend all coolers be checked under the system operating conditions. This is also true for vibrations and mechanical<br />

stress as well as for pressure peaks and thermal stress.<br />

General tolerance according to DIN 2768-g.<br />

The information contained in this homepage is intended to be used as a guideline only. Customers should always confirm the suitability<br />

of the information and these products in their particular applications. <strong>ASA</strong> assumes no liability for any errors, commissions or misprints<br />

and reserves the right to change products and details without prior notification.As we are constantly improving our products, the<br />

characteristics, dimensions and weights can also change, although we do our best to incorporate these changes continually.<br />

asa hydraulik of America <strong>Inc</strong>.<br />

160 Meister Avenue #20A<br />

Branchburg, NJ 08876<br />

Tel.: 800-473-9400<br />

Fax: 908-541-1550<br />

sales_US@asahydraulik.com<br />

www.asahydraulik.com<br />

Copyright 2008 asa hydraulik GmbH


TT 01 12V DC (0.04 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: -<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

0.377<br />

7.980<br />

0.301<br />

6.384<br />

0.226<br />

4.788<br />

0.151<br />

3.192<br />

0.075<br />

1.596<br />

1 3 4 5<br />

Qp [GPM]<br />

1 3 4 5<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0013UD01 0.04 <strong>HP</strong> 0.3 A IP 20 2800 RPM 70.6 SCFM 44 db(A) 3.08 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


TT 01 24V DC (0.04 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: -<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

0.377<br />

7.980<br />

0.301<br />

6.384<br />

0.226<br />

4.788<br />

0.151<br />

3.192<br />

0.075<br />

1.596<br />

1 3 4 5<br />

Qp [GPM]<br />

1 3 4 5<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0013UD02 0.04 <strong>HP</strong> 0.15 A IP 20 2800 RPM 70.6 SCFM 44 db(A) 3.08 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


*Note – Cooling Performance<br />

The cooling performance mentioned in this homepage is conservative and measured at a test bench according to asa test procedures<br />

with oil type ISO VG 46 and presents a bases for your cooler selection regarding required cooling performance. Because there is no<br />

standard test procedure, tests used by other manufacturers might have different results. Due to different environment conditions the<br />

cooling performance can vary by +/- 15%.<br />

Therefore we recommend all coolers be checked under the system operating conditions. This is also true for vibrations and mechanical<br />

stress as well as for pressure peaks and thermal stress.<br />

General tolerance according to DIN 2768-g.<br />

The information contained in this homepage is intended to be used as a guideline only. Customers should always confirm the suitability<br />

of the information and these products in their particular applications. <strong>ASA</strong> assumes no liability for any errors, commissions or misprints<br />

and reserves the right to change products and details without prior notification.As we are constantly improving our products, the<br />

characteristics, dimensions and weights can also change, although we do our best to incorporate these changes continually.<br />

asa hydraulik of America <strong>Inc</strong>.<br />

160 Meister Avenue #20A<br />

Branchburg, NJ 08876<br />

Tel.: 800-473-9400<br />

Fax: 908-541-1550<br />

sales_US@asahydraulik.com<br />

www.asahydraulik.com<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0115 Hyd. Motor .73 Cu.In. 1000rpm (0.03<br />

<strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: -<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

4.960<br />

29.000<br />

3.968<br />

23.200<br />

2.976<br />

17.400<br />

1.984<br />

11.600<br />

0.992<br />

5.800<br />

13 25 38 50<br />

Qp [GPM]<br />

14 28 41 55<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0115AH12 0.03 <strong>HP</strong> - - 1000 RPM 370.65 SCFM 66 db(A) 52.8 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0115 Hyd. Motor .73 Cu.In. 2000rpm (0.26<br />

<strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: -<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

9.100<br />

29.000<br />

7.280<br />

23.200<br />

5.460<br />

17.400<br />

3.640<br />

11.600<br />

1.820<br />

5.800<br />

13 25 38 50<br />

Qp [GPM]<br />

14 28 41 55<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0115AH12 0.26 <strong>HP</strong> - - 2000 RPM 706 SCFM 82 db(A) 52.8 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0115 Hyd. Motor .73 Cu.In. 3000rpm (0.88<br />

<strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: -<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

11.600<br />

29.000<br />

9.280<br />

23.200<br />

6.960<br />

17.400<br />

4.640<br />

11.600<br />

2.320<br />

5.800<br />

13 25 38 50<br />

Qp [GPM]<br />

14 28 41 55<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0115AH12 0.88 <strong>HP</strong> - - 3000 RPM 1323.75 SCFM 90 db(A) 52.8 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


*Note – Cooling Performance<br />

The cooling performance mentioned in this homepage is conservative and measured at a test bench according to asa test procedures<br />

with oil type ISO VG 46 and presents a bases for your cooler selection regarding required cooling performance. Because there is no<br />

standard test procedure, tests used by other manufacturers might have different results. Due to different environment conditions the<br />

cooling performance can vary by +/- 15%.<br />

Therefore we recommend all coolers be checked under the system operating conditions. This is also true for vibrations and mechanical<br />

stress as well as for pressure peaks and thermal stress.<br />

General tolerance according to DIN 2768-g.<br />

The information contained in this homepage is intended to be used as a guideline only. Customers should always confirm the suitability<br />

of the information and these products in their particular applications. <strong>ASA</strong> assumes no liability for any errors, commissions or misprints<br />

and reserves the right to change products and details without prior notification.As we are constantly improving our products, the<br />

characteristics, dimensions and weights can also change, although we do our best to incorporate these changes continually.<br />

asa hydraulik of America <strong>Inc</strong>.<br />

160 Meister Avenue #20A<br />

Branchburg, NJ 08876<br />

Tel.: 800-473-9400<br />

Fax: 908-541-1550<br />

sales_US@asahydraulik.com<br />

www.asahydraulik.com<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0367 <strong>230</strong>/<strong>460V</strong> (<strong>60Hz</strong>) (0.5 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: 20.8 in<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

28.050<br />

42.000<br />

22.440<br />

33.600<br />

16.830<br />

25.200<br />

11.220<br />

16.800<br />

5.610<br />

8.400<br />

25 50 75 100<br />

Qp [GPM]<br />

25 50 75 100<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0367AA66 0.5 <strong>HP</strong> 0.95 A IP 55 1130 RPM 1659.1 SCFM 76 db(A) 138.6 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0367 <strong>230</strong>/<strong>460V</strong> (<strong>60Hz</strong>) (0.75 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: 20.8 in<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

33.100<br />

42.000<br />

26.480<br />

33.600<br />

19.860<br />

25.200<br />

13.240<br />

16.800<br />

6.620<br />

8.400<br />

25 50 75 100<br />

Qp [GPM]<br />

25 50 75 100<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0367AA46 0.75 <strong>HP</strong> 1.25 A IP 55 1690 RPM 2118 SCFM 82 db(A) 130.9 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0367 <strong>230</strong>/<strong>460V</strong> (<strong>60Hz</strong>) (1.5 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: 22 in<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

39.000<br />

42.000<br />

31.200<br />

33.600<br />

23.400<br />

25.200<br />

15.600<br />

16.800<br />

7.800<br />

8.400<br />

25 50 75 100<br />

Qp [GPM]<br />

25 50 75 100<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0367AA48 1.5 <strong>HP</strong> 2.3 A IP 55 1740 RPM 2884 SCFM 86 db(A) 141.02 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


*Note – Cooling Performance<br />

The cooling performance mentioned in this homepage is conservative and measured at a test bench according to asa test procedures<br />

with oil type ISO VG 46 and presents a bases for your cooler selection regarding required cooling performance. Because there is no<br />

standard test procedure, tests used by other manufacturers might have different results. Due to different environment conditions the<br />

cooling performance can vary by +/- 15%.<br />

Therefore we recommend all coolers be checked under the system operating conditions. This is also true for vibrations and mechanical<br />

stress as well as for pressure peaks and thermal stress.<br />

General tolerance according to DIN 2768-g.<br />

The information contained in this homepage is intended to be used as a guideline only. Customers should always confirm the suitability<br />

of the information and these products in their particular applications. <strong>ASA</strong> assumes no liability for any errors, commissions or misprints<br />

and reserves the right to change products and details without prior notification.As we are constantly improving our products, the<br />

characteristics, dimensions and weights can also change, although we do our best to incorporate these changes continually.<br />

asa hydraulik of America <strong>Inc</strong>.<br />

160 Meister Avenue #20A<br />

Branchburg, NJ 08876<br />

Tel.: 800-473-9400<br />

Fax: 908-541-1550<br />

sales_US@asahydraulik.com<br />

www.asahydraulik.com<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0115 <strong>230</strong>/<strong>460V</strong> (<strong>60Hz</strong>) (0.33 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: 16.9 in<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

7.375<br />

29.000<br />

5.900<br />

23.200<br />

4.425<br />

17.400<br />

2.950<br />

11.600<br />

1.475<br />

5.800<br />

13 26 40 53<br />

Qp [GPM]<br />

14 28 41 55<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0115AA44 0.33 <strong>HP</strong> 0.7 A IP 55 1700 RPM 880 SCFM 79 db(A) 56 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0115 <strong>230</strong>/<strong>460V</strong> (<strong>60Hz</strong>) (1.5 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: 18.2 in<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

12.239<br />

29.000<br />

9.791<br />

23.200<br />

7.343<br />

17.400<br />

4.895<br />

11.600<br />

2.448<br />

5.800<br />

13 26 40 53<br />

Qp [GPM]<br />

14 28 41 55<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0115AA27 1.5 <strong>HP</strong> 2 A IP 55 3450 RPM 1860 SCFM 87 db(A) 70 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


*Note – Cooling Performance<br />

The cooling performance mentioned in this homepage is conservative and measured at a test bench according to asa test procedures<br />

with oil type ISO VG 46 and presents a bases for your cooler selection regarding required cooling performance. Because there is no<br />

standard test procedure, tests used by other manufacturers might have different results. Due to different environment conditions the<br />

cooling performance can vary by +/- 15%.<br />

Therefore we recommend all coolers be checked under the system operating conditions. This is also true for vibrations and mechanical<br />

stress as well as for pressure peaks and thermal stress.<br />

General tolerance according to DIN 2768-g.<br />

The information contained in this homepage is intended to be used as a guideline only. Customers should always confirm the suitability<br />

of the information and these products in their particular applications. <strong>ASA</strong> assumes no liability for any errors, commissions or misprints<br />

and reserves the right to change products and details without prior notification.As we are constantly improving our products, the<br />

characteristics, dimensions and weights can also change, although we do our best to incorporate these changes continually.<br />

asa hydraulik of America <strong>Inc</strong>.<br />

160 Meister Avenue #20A<br />

Branchburg, NJ 08876<br />

Tel.: 800-473-9400<br />

Fax: 908-541-1550<br />

sales_US@asahydraulik.com<br />

www.asahydraulik.com<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0115 12V DC (0.34 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: -<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

8.000<br />

20.310<br />

6.400<br />

16.248<br />

4.800<br />

12.186<br />

3.200<br />

8.124<br />

1.600<br />

4.062<br />

13 26 40 53<br />

Qp [GPM]<br />

13 26 40 53<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0115AD01 0.34 <strong>HP</strong> 19.4 A IP 68 2850 RPM 1094.3 SCFM 79 db(A) 27.06 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


<strong>ASA</strong> 0115 24V DC (0.34 <strong>HP</strong>)<br />

A: - F: -<br />

B: - G: -<br />

C: - L: -<br />

D: - W: -<br />

E: -<br />

Pspez [BTU/min°F]<br />

Cooling Performance*<br />

P [PSI]<br />

Pressure Drop<br />

8.000<br />

20.310<br />

6.400<br />

16.248<br />

4.800<br />

12.186<br />

3.200<br />

8.124<br />

1.600<br />

4.062<br />

13 26 40 53<br />

Qp [GPM]<br />

13 26 40 53<br />

Qp [GPM]<br />

Order Number Motor <strong>Power</strong> Current Protection Level Rotation Air Flow Noise Level Weight<br />

<strong>ASA</strong>0115AD02 0.34 <strong>HP</strong> 9.7 A IP 68 2850 RPM 1094.3 SCFM 79 db(A) 27.06 lbs<br />

Working pressure (static): 26 bar (370 PSI)<br />

Radiator material: Aluminium<br />

Copyright 2008 asa hydraulik GmbH


*Note – Cooling Performance<br />

The cooling performance mentioned in this homepage is conservative and measured at a test bench according to asa test procedures<br />

with oil type ISO VG 46 and presents a bases for your cooler selection regarding required cooling performance. Because there is no<br />

standard test procedure, tests used by other manufacturers might have different results. Due to different environment conditions the<br />

cooling performance can vary by +/- 15%.<br />

Therefore we recommend all coolers be checked under the system operating conditions. This is also true for vibrations and mechanical<br />

stress as well as for pressure peaks and thermal stress.<br />

General tolerance according to DIN 2768-g.<br />

The information contained in this homepage is intended to be used as a guideline only. Customers should always confirm the suitability<br />

of the information and these products in their particular applications. <strong>ASA</strong> assumes no liability for any errors, commissions or misprints<br />

and reserves the right to change products and details without prior notification.As we are constantly improving our products, the<br />

characteristics, dimensions and weights can also change, although we do our best to incorporate these changes continually.<br />

asa hydraulik of America <strong>Inc</strong>.<br />

160 Meister Avenue #20A<br />

Branchburg, NJ 08876<br />

Tel.: 800-473-9400<br />

Fax: 908-541-1550<br />

sales_US@asahydraulik.com<br />

www.asahydraulik.com<br />

Copyright 2008 asa hydraulik GmbH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!