20.06.2015 Views

INSIDE INSIDE - Plumbing & HVAC

INSIDE INSIDE - Plumbing & HVAC

INSIDE INSIDE - Plumbing & HVAC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Pipes, Valves & Fittings<br />

Waste piping system<br />

Fuseal polypropylene and Fuseal 25/50<br />

polyvinylidene fluoride corrosive waste<br />

piping systems feature high flame retardant<br />

capabilities and high strength at<br />

elevated temperatures. Fittings include<br />

double 45-degree wyes in 1-1/2 to fourinch<br />

sizes, double reducing wyes of 2 x<br />

1-1/2 to 4x 3-inches, along with electrofusion<br />

or mechanical joining systems.<br />

Geo. Fischer Sloane Circle no. 331<br />

Digital control valves<br />

Spence DigiBoss high-capacity hung<br />

cage guided control valves<br />

for modulating applications<br />

feature a digital electronic<br />

actuator, stall-proof<br />

motor that permits shutoff<br />

up to 750 psi, cast iron,<br />

carbon steel or chrome<br />

moly bodies in two to<br />

eight-inch sizes with NPT,<br />

RF and DIN flanged connections.<br />

Spence Engineering Co. Circle no. 332<br />

Grease-oils removal<br />

Big Dipper units remove and recover<br />

nearly 100 percent of grease, fats, solids<br />

and oils from kitchen and food processing<br />

flows, eliminating<br />

traps, interceptors<br />

and pumping<br />

costs. There are<br />

point of source<br />

and central models,<br />

both with internal<br />

strainers of<br />

1.16 to 3.7-gal.,<br />

and automatic solids transfer, with a 20-<br />

40 lbs./hr skimming rate.<br />

Thermaco Inc. Circle no. 333<br />

Mixing valves<br />

Honeywell AMX Series mixing valves<br />

allow the water heater temperature to<br />

be higher than the safely mixed water at<br />

the faucet. Features include a unique recirculation<br />

port that allows hot water to<br />

continuously circulate through the<br />

house. It is adjustable from 90 to 130°F,<br />

includes a built-in check valve and is<br />

solid brass.<br />

Honeywell Ltd. Circle no. 334<br />

Termination flange<br />

The Copper Stopper termination flange<br />

from Kamco transitions a copper tube<br />

back to standard pipe in both indoor<br />

and outdoor<br />

natural gas<br />

applications.<br />

The<br />

cast bronze<br />

flange eliminates<br />

several<br />

feet of excess tube awaiting hook-up to<br />

an appliance, prevents damage to the<br />

tubing, enables pressuring testing and<br />

fits all 3/8, 1/2 and 5/8-inch fittings.<br />

Kamco Products Circle no. 335<br />

Pressure reducing<br />

Apollo A127 LF pressure reducing<br />

valves maintain constant lower downstream<br />

pressure across a wide flow<br />

range, with a pilot valve operating free<br />

of pressure fall-off. Features include a<br />

combined regulator<br />

bypass and<br />

a pilot-operated<br />

main valve with<br />

two smaller<br />

PRVs and a<br />

strainer. It is<br />

available in sizes from 1-1/4-in. or 32<br />

mm to six inches or 150 mm, and temperatures<br />

from 32 - 180°F with a range<br />

of connections.<br />

Conbraco Industries Circle 336<br />

Pipe support<br />

The Caddy rooftop pipe support system<br />

is a UV-rated ‘sled-design’ support with<br />

a 4 x 5 inch<br />

footprint. It<br />

can be bonded<br />

to the roof or<br />

float with pipe<br />

expansion and<br />

contraction. It<br />

holds up to<br />

three 1/2-inch<br />

or two 3/4-inch or 1-inch pipes or conduit.<br />

The pipe-retaining mechanism<br />

ratchets down to hold pipes securely or<br />

can be set for loose guiding.<br />

ERICO Circle no. 337<br />

Flanged circulators<br />

The Armstrong Astro 70F and BF<br />

flanged circulators in cast iron and<br />

bronze are designed for a high head and<br />

low-flow rate<br />

pump with<br />

common twobolt<br />

mounting<br />

flanges or union<br />

and sweat connections.<br />

Features<br />

include a<br />

screw-less terminal<br />

strip and lever-operated spring<br />

clamps that grip each conductor for<br />

easy connection.<br />

Armstrong Pump Circle no. 338<br />

Steel PEX clamp<br />

A stainless steel clamp from CPI connects<br />

Dura-Pro fittings on Dura-PEX<br />

piping installations to create a temperature,<br />

pressure-tight and leak-free connection<br />

between<br />

clamp and insert<br />

fittings. Unique<br />

tabs on clamping<br />

ears allow the<br />

use of a single clamp installation tool<br />

for all clamp sizes.<br />

Consolidated <strong>Plumbing</strong> Ind. Circle no. 339<br />

23 - 428 Millen Road, Stoney Creek, Ontario L8E 3N9<br />

Phone: (905) 664-8274 • Toll Free: 1-800-527-HEAT (4328) • Fax: (905) 664-8846<br />

www.superiorradiant.com sales@superiorradiant.com<br />

Pressure reducing<br />

The TLV DR20 compact lightweight<br />

steam system pressure reducing valve is<br />

a flow-up design with a flat valve and<br />

plug arrangement to promote secondary<br />

pressure stability<br />

to reach a turnover<br />

ratio of 30:1. It features<br />

stainless steel<br />

packless construction<br />

with a bellows diaphragm<br />

and a builtin<br />

screen.<br />

TLV Corp. Circle no. 340<br />

A full range of infrared space heating equipment<br />

Model RE (for workshops, residential garages)<br />

• rates from 30 and 45 MBTUH<br />

• balanced flue construction<br />

• 85% thermal efficiency<br />

• fully assembled for installation ease<br />

TECH TIP<br />

Equalizing sump water levels<br />

By Jerry Boulanger<br />

If two or more sumps (cooling towers for example) are installed in parallel<br />

it is common to have equalizing lines connecting them so that<br />

they operate at the same water level. The only differential pressure<br />

available to push water from sump to sump is the difference in the<br />

sump water levels. In some applications, this static head differential<br />

may only be on the order of a few inches of water column before the<br />

water level in the high sump reaches the overflow outlet. For example, a six-foot<br />

length of two-inch steel pipe with a ball valve installed between sumps will only flow<br />

about 30 US gpm from one sump to the other if the difference in the sump water levels<br />

is four inches. If equalization lines are not properly sized to handle the required flow at<br />

low differentials, the high sump may flood and lose water (and possibly chemical) out<br />

the overflow. This can be an expensive problem. Increasing the size of the equalization<br />

line, including the entry and exit openings into the sumps, will keep the sumps close to<br />

the same level.<br />

Jerry Boulanger is national sales manager for Axiom Industries Ltd., Saskatoon, Sask.<br />

He can be reached at jboulanger@axiomind.com.<br />

Model Premier VS (engineered performance)<br />

• a vacuum operated burner-in-series system that is<br />

engineered for the customer’s specific requirements<br />

• burner rates 60 to 250 MBTUH<br />

with multiple branch capability<br />

• system outputs to one million BTUH<br />

• state of the art electronic control panel<br />

Two High Low Valves<br />

For the Price of One.<br />

Introducing the Leonard “New Generation” Hi-Low System<br />

SUPERIOR RADIANT PRODUCTS<br />

Model UA (workhorse of the line up)<br />

• rates from 40 to 220 MBTUH<br />

• jet stream burner design maximizes<br />

radiant output<br />

• deep dish reflectors are 100% efficient<br />

• warranty: 3 yr. on parts, 5 yr. on heat exchanger.<br />

Model UX (more features, more<br />

performance)<br />

• fully enclosed construction<br />

• operating status lights<br />

• standard 24v thermostat<br />

• post purge function<br />

• 10 yr. heat exchanger<br />

warranty option<br />

Circle Number 129 for More Information<br />

www.plumbingandhvac.ca November/December 2005 – <strong>Plumbing</strong> & <strong>HVAC</strong> Product News 27<br />

NEW<br />

• Maximum Dual-Valve Safety<br />

• Same Price As Single Valves<br />

• Legendary Leonard Reliability<br />

• Simple design, easy installation<br />

1360 Elmwood Avenue, Cranston, RI 02910, 888-797-4456, Fax 401-941-5310<br />

www.leonardvalve.com info@leonardvalve.com<br />

Circle Number 128 for More Information

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!