Facility <strong>Spec</strong>ifications<br />

Purifier Model <strong>PS22</strong>-<strong>MGT</strong>40-CDA <strong>PS22</strong>-<strong>MGT</strong>50-CDA <strong>PS22</strong>-<strong>MGT</strong>60-CDA<br />

Dimensions<br />

Purifier Clearance<br />

Mechanical Connections<br />

Regeneration Vent Temp.<br />

Purify Time<br />

Height: 1675 mm (~66 in)<br />

Width: 865 mm (~34 in)<br />

Depth: 610 mm (~24 in)<br />

Weight: < 180 Kg (< 400 lbs.)<br />

1 meter ( ~3 feet) in front and back<br />

Feed Inlet: ½” FVCR<br />

Purified Outlet: ½” FVCR<br />

Regeneration/Relief Vent: ½” FVCR<br />

Cabinet Vent: 4” duct<br />

Instrument Air Inlet: 3/8” FNPT<br />

Ambient air + 30°C (+ 54°F)<br />

Programmable<br />

CDA Consumed per Regen 180 m 3 180 m 3 180 m 3<br />

Main Power<br />

Separate Control Power<br />

(Option)<br />

Installed Power: 2.4 kW<br />

208 or 230 VAC, 1 Phase, 50/60 Hz<br />

Power Consumption during Purification: 0.1 kW<br />

Power Consumption during Regen: 1.21 kW<br />

110 or 230 VAC, 1 Phase, 50/60 Hz<br />

Power Consumption: 0.1 kW<br />

Cabinet Ventilation 260 Nm 3 /hr (150 scfm) [@ Facilities Vacuum - 0.2 inches H 2 O]<br />

Installation<br />

Indoor, Ambient Temp (min – max) 5° – 35°C (41° – 95°F)<br />

Dimensions<br />

<strong>PS22</strong>-<strong>MGT</strong>40-CDA (40 Nm3/hr) through <strong>PS22</strong>-<strong>MGT</strong>60-CDA (60 Nm3/hr)<br />

S110‐964_A DCN 4905 4 <strong>Spec</strong>ification subject to change<br />

WWW.TEESING.COM | TEL +31 70 413 07 50