M<strong>ira</strong> <strong>Star</strong><br />

<strong>Microflow</strong><br />

<strong>Radioactivity</strong><br />

<strong>Detector</strong><br />

for µ-HPLC<br />

4 detectors in 1<br />

sr 09/04


MICROFLOW-RADIO-HPLC<br />

M<strong>ira</strong> <strong>Star</strong> flow detector<br />

and electronics<br />

Micro Ramona <strong>Star</strong> is a newly<br />

d e v e l o p e d r a d i o a c t i v i t y<br />

flowthrough detector for the<br />

application of microflow or capillary<br />

HPLC.<br />

M<strong>ira</strong> <strong>Star</strong> consists of a separate<br />

detector unit and an electronic<br />

module to position the detector as<br />

close as possible to the µ-HPLC<br />

system to reduce peak broadening<br />

by long capillaries between the<br />

individual HPLC components.<br />

M<strong>ira</strong> <strong>Star</strong> and a microflow-<br />

HPLC-system<br />

4 DETECTOR S<br />

IN 1<br />

M<strong>ira</strong> <strong>Star</strong> has 4 separate<br />

coincidence flow detectors aligned<br />

in series in one detector. Every<br />

single separate subdetector<br />

counts the flowthrough activity<br />

profile in the small cell volume. At<br />

the end, all 4 profiles are<br />

s e q u e n t i a l l y d e l a y e d ,<br />

accumulated in phase and added<br />

to one peak profile. Therefore the<br />

sensitivity is 4 times higher than 1<br />

flowdetector.<br />

Flow rates in microflow HPLC are<br />

typically in the range of 10-100<br />

µl/min. Typically µ-flow HPLC<br />

columns have internal diameters of<br />

less than 1 mm. The separation<br />

performance of these columns is<br />

equal or even higher than standard<br />

HPLC columns. The consumption<br />

of eluents is for µ-HPLC<br />

applications much lower than in<br />

standard HPLC. And therefore the<br />

disposal of contaminated eluent<br />

waste is less laborous and less<br />

expensive.<br />

Small column diameter means<br />

small sample volume injection for<br />

separation.<br />

Small sample volume means that<br />

separated fractions in HPLC have<br />

a very small peak volume.<br />

Small peak volume produce small<br />

activity peaks (small numbers of<br />

counts detected).<br />

To obtain sufficient sensitivity for<br />

these small numbers of counts it<br />

was required to mount four<br />

separate subdetectors in series.<br />

VERSA TILE APPLICATIONS M<strong>ira</strong> <strong>Star</strong> internal<br />

solid scintillator cell<br />

M<strong>ira</strong> <strong>Star</strong> can be equipped with<br />

various flowcells with solid<br />

scintillators for almost every<br />

application. Scintillator materials<br />

are CaF and Li-glass as well as a<br />

new scintillator material, called US.<br />

The different solid scintillator cells<br />

are available in various volumes<br />

and many grades of particle size<br />

to optimize sensitivity and<br />

resolution.


FLEXI BLE USE<br />

M<strong>ira</strong> <strong>Star</strong> external<br />

solid scintillator cell<br />

M<strong>ira</strong> <strong>Star</strong> also can be equipped<br />

with flowcells with external solid<br />

scintillators. A coil of PTFE-tubing<br />

is positioned between 2 solid<br />

scintillator disks. The radiation<br />

penetrates the wall of the tubing<br />

and hits the external scintillator<br />

disk. Such an arrangement is<br />

suitable for high energy beta<br />

applications with plastic scintillator<br />

material or low energy gamma<br />

applications with BGO-scintillator<br />

disks. The cell volume can be<br />

customized to the required size.<br />

LIQUID SCINTILLATOR ADMIXTURE<br />

M<strong>ira</strong> <strong>Star</strong> liquid scintillator cell<br />

M<strong>ira</strong> <strong>Star</strong> is suitable for liquid<br />

scintillator admixture using liquid<br />

scintillator cells and the Ramona<br />

HPLC-LS pump with a delivery<br />

rate of 100-2000 µl/min. Capillary<br />

tubing and small flowcell volume<br />

require low viscosity liquid<br />

s c i n t i l l a t o r c o c k t a i l s . B i o -<br />

degradable LS-cocktails are<br />

preferred.<br />

M<strong>ira</strong> <strong>Star</strong> LS-admixture pump<br />

GLP A ND GMP COMPLIANCE M<strong>ira</strong> <strong>Star</strong> flow cell identification<br />

M<strong>ira</strong> <strong>Star</strong> flow cells have the same<br />

unique cell recognition feature as<br />

Ramona <strong>Star</strong>. Every flowcell<br />

carries a readable microchip,<br />

storing the individual identification<br />

and all parameters required for<br />

GLP and GMP compliance. Data<br />

f r o m t h i s m i c r o c h i p a r e<br />

automatically transferred to Gina<br />

<strong>Star</strong> software.<br />

M<strong>ira</strong> <strong>Star</strong> can easily be integrated<br />

into a microflow HPLC-system,<br />

e v e n w h e n u s i n g a<br />

massspectrometric detector<br />

(MSD).<br />

Agilent MSD


aytest Worldwide<br />

<strong>raytest</strong> Isotopenmessgeräte GmbH<br />

Benzstr. 4<br />

D-75334 Straubenhardt<br />

Tel +49 7082 92550<br />

info@<strong>raytest</strong>.de<br />

<strong>raytest</strong> Austria GesmbH<br />

Uferstr. 15-19/9<br />

A-2103 Langenzersdorf<br />

Tel +43 2244 30 890<br />

austria@<strong>raytest</strong>.de<br />

<strong>raytest</strong> BeNeLux B.V.<br />

Spoorlaan 438A<br />

NL-5038 CH Tilburg<br />

Tel +31 135 4336 19<br />

benelux@<strong>raytest</strong>.de<br />

<strong>raytest</strong> France S.A.<br />

Cedex<br />

F-92052 Paris la Defense<br />

Tel +33 1 433 433 33<br />

france@<strong>raytest</strong>.de<br />

<strong>raytest</strong> Italia S.R.L.<br />

Via G. Matteotti, 54/66<br />

I-20092 Cinisello Balsamo<br />

Tel +39 02 6129 3798<br />

italy@<strong>raytest</strong>.de<br />

<strong>raytest</strong> Iberica S.L.<br />

Travador, 43-35 bajos<br />

E-08041 Barcelona<br />

Tel +34 93 4500 875<br />

iberica@<strong>raytest</strong>.de<br />

<strong>raytest</strong> Schweiz AG<br />

Bernstr. 388<br />

CH-8953 Dietikon<br />

Tel +41 1740 1069<br />

switzerland@<strong>raytest</strong>.de<br />

<strong>raytest</strong> USA Inc.<br />

515 Cornelius Harnett Drive<br />

Wilmington NC 2840<br />

Tel +1 910 343 1830<br />

Usa@<strong>raytest</strong>.de<br />

Raytek Scientific Ltd<br />

26 Norton Park View<br />

Sheffield S8 8GS<br />

Tel +44 0114 274 9575<br />

uk@<strong>raytest</strong>.de<br />

Technical data<br />

eluate flow rate: 10 - 300 µl/min<br />

dead volume: 1 - 2 µl<br />

connection: capillary tubing<br />

14C, 33P, 35S etc<br />

Internal solid scintillator: US, CaF, Li-glass<br />

particle size 30 > 100 µm<br />

cell volume 4 x (3 - 45) µl<br />

efficiency 40 - 90%<br />

3H<br />

internal liquid scintillator: 200 - 2000 µl/min<br />

cell volume 4 x (3 - 100) µl<br />

efficiency 40 - 60%<br />

32P etc<br />

external solid scintillator: plastic or<br />

Cerenkov<br />

effect<br />

cell volume 4 x (3 - 100) µl<br />

efficiency 60 - 80%<br />

125I etc<br />

external solid scintillator BGO<br />

cell volume 4 x (3 - 100) µl<br />

efficiency 20 - 30%<br />

standalone detector<br />

detector module: 250 x 80 x 200 mm<br />

(B x H x T)<br />

low dead volume<br />

connection<br />

electronic module: 320 x 170 x 260 mm<br />

(B x H x T)<br />

data transfer: analog, 0-1V (21 bit)<br />

Gina <strong>Star</strong> detector control<br />

same as stand alone but including data<br />

transfer to Gina <strong>Star</strong> software<br />

Digital (single event counting), never out-of-<br />

range problems, never smoothing problems,<br />

digital peak integration, calculation of<br />

statitistical variation, calculation of limit of<br />

detection, simple validation<br />

<strong>raytest</strong> Isotopenmessgeräte GmbH<br />

Benzstrasse 4, 75334 Straubenhardt<br />

www.<strong>raytest</strong>.de • info@<strong>raytest</strong>.de<br />

Tel. +49 (7082) 9255-0<br />

Fax. +49 (7082) 20813<br />

M<strong>ira</strong> <strong>Star</strong> detector, electronics, flow cell<br />

M<strong>ira</strong> <strong>Star</strong> front panel<br />

M<strong>ira</strong> <strong>Star</strong> back panel<br />

<strong>raytest</strong> USA, Wilmington, NC • raytek Scientific UK, Sheffield • <strong>raytest</strong> Italia, Cinisello Balsamo • <strong>raytest</strong> France, Courbevoie • <strong>raytest</strong> Benelux, Tilburg<br />

<strong>raytest</strong> Switzerland, Dietikon • <strong>raytest</strong> Iberica, Barcelona • <strong>raytest</strong> Austria, Langenzersdorf

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!