Primary System ComponentsSupply fan and return fanThe final configuration uses a fan in the return-air path, rather than in theexhaust air path. When the system includes a return fan, the supply fan muststill create the same pressure at its outlet (A) to overcome the pressure lossesassociated with the supply-air path (Figure 22).Figure 22. <strong>VAV</strong> system with supply and return fans (25% outdoor air)zonereturn-air grille,ceiling plenum,return ductworkAHUmain supplyductwork<strong>VAV</strong>terminalunitsupply ductrunouts,diffuserszonestatic pressure relative to outdoors+0-returnfanFCAsupplyfanBreturn-airdamperHowever, the pressure at the inlet of the supply fan (B) only needs to be lowenough to overcome the pressure losses associated with drawing the returnair through the return-air damper, filter, and coils (or the pressure associatedwith drawing the outdoor air through the outdoor-air damper, whichever ishigher). The return fan is used to overcome the pressure losses associatedwith drawing the return air out of the zones and through the return-air grilles,open ceiling plenum and/or return ductwork. It must also generate enoughpressure (F) to push any relief air out through the relief damper.Should the system use a relief fan or a return fan?The “supply fan and relief fan” configuration usually works best in <strong>VAV</strong>systems that use an open ceiling plenum for part of the return-air path(Table 5). <strong>Systems</strong> with relief fans are easier to control, typically lower thecost of the air-handling unit, and are often less costly to operate than systemswith return fans. (See “Building pressure control,” p. 178.)When the pressure drop through the return-air path is very high (which maybe the case in a larger system with a fully ducted return-air path), evaluateboth the relief- and the return-fan configurations. If the supply fan is capableof handling the pressure drop of both the supply- and return-air paths, thenthe relief-fan configuration is preferred for the reasons mentioned above. Usea return fan only if the return-air path adds more pressure drop than thesupply fan can handle.30 <strong>Chilled</strong>-<strong>Water</strong> <strong>VAV</strong> <strong>Systems</strong> SYS-APM008-EN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!