10.07.2015 Views

Local Land and Property Gazetteer - Iahub.net

Local Land and Property Gazetteer - Iahub.net

Local Land and Property Gazetteer - Iahub.net

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

• BLPU extent: in allocating the relevant Name <strong>and</strong> Number care shouldbe taken to define any relevant spatial extent by cross checking with theapproved planning permission. At this stage there will not be set of OSfeatures or DNF TOIDs available on the Ordnance Survey Base Map.Therefore the custodian will need to make a judgement based on planningapplication or building control submissions. Thus definition of the spatialextents is highly likely to be subject to future change when the scheme hasbeen completed, <strong>and</strong> the Ordnance Survey have undertaken the relevantsurvey work, <strong>and</strong> updated the maps accordingly. The source descriptionshould be entered appropriately allowing the Custodian to identify extentsthat may require future amendment.The Street Naming <strong>and</strong> Numbering Order should include relevant c<strong>and</strong>idate BLPUUPRN details.Note: that for large schemes especially where it is a mixed use scheme theNaming <strong>and</strong> Numbering might be best undertaken in two stages. Stage 1 forthe Level 1 site or property where it is straightforward to identify a building as160-190, Number House North Street. However, at this stage it might not beclear as to internal arrangements of Level 2 BLPUs such as retail units. ThusStage 2 may involve allocation of individual numbers to Level 2 BLPUs suchas retails units, as the layout of the scheme becomes more definitive.(A possible future amendment to BS7666 Part 2 - Table 3 - BLPU Logical statuswould be to add 6 C<strong>and</strong>idate - new development.)A5Development MonitoringHaving set up the relevant details as a c<strong>and</strong>idate entry the scheme needs tobe monitored to see whether it is implemented. If so the Logical Statusneeds to be amended from C<strong>and</strong>idate to Approved. There are a variety ofdata sources, which can be utilised:• Some local planning authorities undertake monitoring of planningpermissions <strong>and</strong> publish schedules of progress. For examplehttp://www.cityoflondon.gov.uk/planning/development/devscheduleintro.htm.• Progress on schemes can also be monitored through the process ofundertaking survey work for the purposes of submissions to the National<strong>L<strong>and</strong></strong> Use Database <strong>and</strong> in Greater London the Greater LondonDevelopment Monitoring System.• Building Control Initial Notice• Certificate of CompletionVersion : 4Date: 18/02/05 Page 35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!