Analyzers and Systems for Process Control and Emission Monitoring

Analyzers and Systems for Process Control and Emission Monitoring

Analyzers and Systems for Process Control and Emission Monitoring

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Engineering <strong>and</strong> Planning – from Individual Devices to Complete Analysis <strong>Systems</strong>:Turnkey systems tailored to your needs.Multi-Purpose Analysis<strong>Systems</strong>With a wide range of individualmeasuring devices, multicomponentanalyzers, <strong>and</strong>complete analysis systems,the SICK group is best equippedto meet all of your measuringrequirements.All our products are based onour wealth of experience froma wide variety of industries.As different as their areas ofapplication are, each of ourmeasuring systems is planned<strong>for</strong> the specific needs ofour customers. In addition tost<strong>and</strong>ard solutions, the SICKgroup also provides tailormadeconcepts. Each of productofferings is designed specificallyin line with the requirements<strong>and</strong> conditions onsite. These specific solutionsare precise, quick, <strong>and</strong> costeffective. As well as providingthe technology, the SICKgroup also carries out projectplanning <strong>for</strong> entire gas analysisinstallations, <strong>for</strong> example,in accessible, turnkey containers.These can contain theentire gas analysis equipment– from the measuring equipmentto the emissions monitoringsystem.


Direct gas analysis:GM 31 – The All-RounderIn-Situ MeasuringTechnology FromSIn-situ measurementMulti-component gas analyzer<strong>for</strong> NO, SO 2, NH 3or NO 2The in-situ analyzers fromS are available in twoversions: “cross-stack” <strong>and</strong>“analyzers with a directmeasuring probe”. This enablesthe devices to beadapted efficiently to awide variety of differentsystem configurations.Cross-stack Measurement across theentire cross section of thechannel; this produces resultswith high statisticalrepresentation. Determination of gas concentrationsin real time; thismeans very fast measurement,results reflect thecurrent state of the process.Probe technique Eliminates the disturbing effectthat dust in the gaschannel has on measurements;ideal <strong>for</strong> applicationswith high dust concentrations. Also suitable <strong>for</strong> difficultmeasurement tasks suchas overpressure, “wet” gasesor very high gas concentrations Permits gas to be tested;i.e. immediate verification ofall measuring results.The advantages of in-situmeasurement Direct <strong>and</strong> immediate measurementin processes. Non-contact measurement;there<strong>for</strong>e suitable <strong>for</strong> usewith aggressive or corrosivegases. Very short response times. Very low maintenancerequirements.Technical dataSystem modulesMeasuring principleMeasuring variable,Measuring rangeInterfacesEnclosure ratingTest functionInstant <strong>and</strong> reliablemeasurement of SO 2 , NO,NH 3 or NO 2 .The GM 31 is suitable <strong>for</strong>both simultaneous or individualmeasurements <strong>and</strong> can beused to measure emissionsin flue-gas desulphurization<strong>and</strong> DeNox plants.Applications Power stations Cement industry Refuse incineration plants Petrochemical industries Chemical industriesGM 31AdvantagesTransmitter/receiver unit, measuring robe, control unitTransmission (UV-spectroscopy) Fast <strong>and</strong> continuous measurements– directly in thegas-carrying duct Easy to install, commission<strong>and</strong> maintain Remote diagnosis viamodem O 2 measurements easypossible by connecting anexternal sensor Internal temperature measurement Calculated value output(mg/m 3 in operating/st<strong>and</strong>ard state, ppm)SO 2: 70 ... 30.000 mg/m 3 NH 3: 30 ... 100 mg/m 3NO: 130 ... 4.000 mg/m 3 NO 2: 100 ... 4.000 mg/m 3RS 232, RS 422IP 65 (IP 20 <strong>for</strong> control unit in control panel version)Automatic check cycle, linearity checkTransmitter/receiverunit<strong>Control</strong>unitPurge-airunitStrip-chartrecorderModemO 2sensor


O 2Analysis with the GM 302GM 910 <strong>for</strong> CO <strong>Monitoring</strong>In-situ measurementZrO 2oxygen analysatorCarbon monoxide analyzerOptimization of industrialcombustion processes <strong>and</strong>reference value calculation.The GM 302 Analyzer providesfast, reliable <strong>and</strong> precisemeasuremets of O 2.Applications Power stations <strong>and</strong> districtheating stations Refuse combustion plants Domestic furnaces, crackinglime <strong>and</strong> cement kilns Quench, sintering, smelting<strong>and</strong> tempering furnacesAdvantages Extendable: up to three O 2sensors can be connectedon one evaluation unit Short response time <strong>for</strong>process control dem<strong>and</strong>s Output via analog signals<strong>and</strong> PROFI BUS No reference gas neccessary Calibration gas “air” used No measuring gas pumpneccessary Temperatures up to1400 °CSecure emission measurement<strong>and</strong> process control.The GM 910 analyzer ensuresthe secure monitoring of COconcentrations, <strong>for</strong> example inindustrial combustion processes.This enables optimizingfiring <strong>and</strong> reducing pollutantlevels as well as fuel consumption.Applications Power stations Refuse incineration plants Cement factories Food industryAdvantages No-contact measurementdirectly in the gas duct Low maintenance requirements Automatic calibration <strong>and</strong>self-test Measurement results arealways accurate, even incloudy or dust-laden atmospheres Robust, waterproof <strong>and</strong>dustproof designLT GM 1302Measuring probe, O 2sensor, evaluation Messsonde, unit O 2-TransmitterCurrent probe (ZrO 2) Stromsonde (ZrO 2)GM 910Transmitter, receiver, connection Sender, unit Empfänger, AnschlusseinheitFilter correlation (IR)Filterkorrelation (IR)O 2: 0 ... 21 % volT: 0 … 1400 °CO 2: O ... 21 Vol. %CO: 300 ... 10,000 mg/m 3 x mCO:300 ...RS 232, RS 422RS 232, RS 422RS 232, RS 422RS 232, RS 422IP 65IP 65IP 65IP 65Self-test functionSelbsttestfunktionAutomatic check cycleAutomatischer KontrollzyklusO 2sensorEvaluationunitTrasmitterReceiverConnection unitStrip-chartrecorderO 2sensorPurge-air unit


GM 901 in “Cross Stack” Version orwith Measuring ProbeGM 35 – The Solution <strong>for</strong> CO, CO 2<strong>and</strong> HumidityIn-situ measurementCarbon monoxide analyzerMulti-component gas analyzer<strong>for</strong> CO, CO 2<strong>and</strong> H 2O<strong>Process</strong> control, e.g. <strong>for</strong>monitoring fuel-burningplants.In addition to its modular concept– the Evaluation Unit canbe deployed up to 1000 mfrom the measuring point –the GM 901 CO Analyzer isavailable as a cross-stack orprobe version. As a result, theGM 901 is ideally suited to abroad range of application,even <strong>for</strong> difficult measuringtasks (e.g. high dust concentrations,overpressure, „wet“flue gases, or extremely highmeasuring gas concentrations).Applications Power plants Cement industry Steel industry Chemical industryAdvantages Easy to install, commission,<strong>and</strong> plan Verifiable using test gases User-friendly operationfrom the Evaluation Unit Measurement values, measuringranges, <strong>and</strong> limit valuescan be read directlyfrom the graphics display Extremely low maintenancerequirementsEfficient control ofcombustion processes<strong>and</strong> dehydration plants.The GM 35 analyzer measuresCO, CO 2, <strong>and</strong> H 2O concentrationsquickly, reliably, <strong>and</strong>economically either simultaneouslyor as individualmeasurements.Applications Power stations <strong>and</strong>cement plants Refuse incineration plants Petrochemical industry Chemical industry Paper <strong>and</strong> textile industry Dehydration <strong>and</strong> humidificationplantsAdvantages Fast <strong>and</strong> continuous measurements– directly in thegas-carrying duct Easy to install, commission<strong>and</strong> maintain Remote diagnosis viamodem O 2 -measurement easy possibleby, <strong>for</strong> example, connectingan external sensor Internal temperature measurement Calculated value output(mg/m 3 in operating/st<strong>and</strong>ard state, ppm)Technical dataSystem modulesMeasuring principleGM 901Transmitter/receiver, EVU, probeGas filter correlationGM 35Transmitter/receiver, evaluation unit, measuring probeFiltercorrelation (IR), gas filter correlationMeasuring variable,Measuring rangeCO: 10O ... 20,000 ppmCO: 0 … 75 up to 10,000 mg/m 3 •mCO 2: 0 ... 10 up to 100 % vol.H 2O: 0 ... 10 up to 100 % vol.InterfacesRS 232, RS 422/485, CAN busRS 232, PROFI BUS (option)Enclosure ratingIP 65IP 65Test functionManual test functionAutomatic check cycleTransmitterReceiverEvaluation unitEVUTransmitter/receiver unitEvaluationunitPurge-air unitStrip-chartrecorderPurge-airunitO 2sensorModemStrip-chartrecorder


MCI 900 – Optimum Combustion in Small-Scale Boiler PlantsMulti-component analyzer system<strong>for</strong> O 2, temperature, CO <strong>and</strong> dustMCI 900Basic configuration Evaluation unit, connection unit, O 2probe,2 temperature sensorsExtended configuration CO monitor, dust monitorMeasuring principle ZrO 2(current-voltage sensor), gas filter correlation,scatter lightMeasuring range O 2: 0,1 … 10 up to 25 Vol.%T: –50 … 400 °CCO: 0 … 100 up to 20,000 ppmdust: 0 … 5 up to 200 mg/m 3InterfacesCAN busEnclosure rating IP 65Test functionManual test functionOptimum combustion processes<strong>and</strong> reduction of pollutants.Oxygen (O2), temperature,carbon monoxide (CO), <strong>and</strong>dust are the controlled variablesthat are essential <strong>for</strong>ecological <strong>and</strong> cost-effectiveoperation of boiler plants. TheMCI 900 multi-component analyzersystem measuresthese variables continuously,instantaneously, <strong>and</strong> accurately.The air ratio λ is significant<strong>for</strong> optimum operatingconditions of a fuel-burningplant. The maximum efficiencylevel λ is reached when theλ value is in the optimum area.S is also making itsextensive experience of analysistechnology <strong>for</strong> large-scaleinstallations available to smallscaleboiler plants. Thanks tothe open “modular designprinciple”, the installation canbe fully equipped at once oron a step-by-step basis.Basic configuration:Evaluation unit, central connectionunit, the GM 301O 2probe with 2 temperaturesensors.Extended configuration:GM 901 CO monitor <strong>and</strong>FW 102 dust monitor.Applications Manufacturers of smallscaleboilers <strong>and</strong> burnermanufacturers Small-scale boiler plants:Universities, clinics, hospitals Gas turbine cogenerationplants Horticulture centersAdvantages Continuous measurementof O 2, temperature, CO, <strong>and</strong>dust Optimum combustion processes,there<strong>for</strong>e moreeconomical operation ofcombustion plants Reduction in pollutant levelsthrough continuous monitoringof CO <strong>and</strong> dust burdens Long, maintenance-free operatingtimes <strong>and</strong> low maintenancerequirements Easy installation <strong>and</strong> operationusing an Evaluation Unit Precise in-situ technology,no test or auxiliary gasesrequired as air is used <strong>for</strong>calibration while the boiler isbeing purged.In-situ measurementDust monitorEvaluation unitCO monitorTemp. sensorcombustion airO 2sensorPurge-airunitTemp. sensorflue gasCentralconnection unitStrip-chartrecorder


CLD <strong>for</strong> Highest Dem<strong>and</strong>s.Extractive measuringtechnologyfrom SChemiluminescence analyzerExtractive measurementGas analysisS has a comprehensiverange of devices <strong>for</strong> extractivegas analysis: Gas sampling probes whichare adapted to the conditionsat the measuring point Sample gas lines, heated<strong>and</strong> unheated Gas coolers, also low-temperaturecoolers, with differentmaterials <strong>Analyzers</strong> <strong>and</strong> analysissystemsAdvantages: Complete systems fromone company, from gassampling equipment toanalyzers <strong>Analyzers</strong> suitable <strong>for</strong> abroad range of differentApplications Task-specific adaptationof the systems is possible Individual solutions adaptedto the specific needs ofthe customer.Selective nitrogen oxidemeasurement over widemeasuring ranges.The GME 66 Chemiluminescenceanalyzers are suitable<strong>for</strong> the precise measurementof nitrogen oxides. Dependingon the device model NO orNO xrespectivily NO, NO x<strong>and</strong>NO 2are measured simultaneously.For the NO xmeasurement,a converter with a longservice life is already integrated.Thanks to the highly selectiveCLD measuring method,the GME 66 supportsmeas uring ranges of 0 … 0.1ppm up to 0 – 10.000 ppm.Applications <strong>Emission</strong> monitoring Chemical industries Refuse incineration plants DeNOx plants Quality control Commercial testing <strong>and</strong>measurement servicesAdvantages High selectivity <strong>and</strong> sensitivity Simultaneous measurementof NO, NO x<strong>and</strong> NO 2 Version <strong>for</strong> hot gases Integrated NO xconverter short response timesTechnische DatenGME 66Measuring principleChemiluminescenceMeasuring variableNO, NO X, (NO 2calculated)Measuring range0 ... 0.1 up to 0 ... 10.000 ppmMeasuring gas pressureca. 800 ... 1,200 mbarMeasuring gas temperature5 ... 45 °C; GME 66-HT u.t. 180 °CInterfacesRS 232Enclosure ratingIP 20Measuring gasPhoto multiplierIR filterMetal coatingof reflectorsDetectorReactionchamber


S 700 ModularSystem – Gas Analysis SystemGas <strong>Analyzers</strong><strong>Process</strong> <strong>and</strong> <strong>Emission</strong>s<strong>Monitoring</strong>.The S700 modular systemmakes configuring tailored applicationsparticularly easy. AnS700 housing can be equippedwith up to 3 analyzermodules <strong>for</strong> compact <strong>and</strong>cost-effective solutions.A total of 6 different analyzermodules are available <strong>for</strong> analyzingup to 60 gas components.Applications:Depending on the measuringtask, installation site, <strong>and</strong> ambientconditions: S 710 (19” housing) <strong>for</strong>st<strong>and</strong>ard applications S 715 <strong>for</strong> rough ambientconditions or explosion protectionzone 2 S 720Ex <strong>for</strong> industrial usein explosion protect. zone 1Advantages: Extremely compact analysissystem Fully automatic measuringmode Low maintenance, easy touse Flexible configuration optionsthanks to a variety ofanalog/digital signal interfaces Measurement value calculation<strong>and</strong> processing; evenfrom external sensors <strong>Monitoring</strong> of external statussignalsOverview of the S 700ModularSystem.Analyzer Modules UNORSelective analysis of IR-absorbinggases MULTORMulti-component analyzer<strong>for</strong> determining up to 4 gascomponents that absorb IRsimultaneously THERMORFor determining the concentrationsusing the thermalconductivity of gasesModuleUNORMULTORTHERMORFINOROXOR-POXOR-EMeasuring method FINORFor determining CO, CO2,<strong>and</strong> CH4 simultaneouslyusing interference filtermethods; no moving parts OXOR-PFor oxygen analysis using aparamagnetic measuringprinciple OXOR-EFor oxygen analysis usingan electrochemical measuringcellComponentsNDIR absorption 1NDIR absorption 4Thermal conductivity 1Interference filter correlation 3Paramagnetic principle 1Electrochemical cell 1Extractive measurementGas analysisTechnical dataS 710 S 715 S 720ExModule 1 Module 2 Module 3Measurement signals4UNORUNORTHERMOROutput rangeCalibrationMeasuring gas pressure2automatical/manual16 ... 250 hPaMULTORFINOROXOR-POXOR-EOXOR-POXOR-EMeasuring gas temperatureInterfacesEnclosure rating0 ... +45 °CRS 232IP 20 IP 65 IP 65OXOR-POXOR-ECom<strong>for</strong>mity/complianceTÜV, TA clean air act, 13., 17. <strong>and</strong>MULTORUNOROXOR-P27. BImSchV (refer page 2)SO 2, NOCO O 2FINORNo module THERMORCO, Overview analyzer modules CO, 2, CO CH 24 , CH 4H 2Example 2 Example 1


MCS 100 <strong>for</strong> <strong>Process</strong> AnalysisMCS 100 E <strong>for</strong> <strong>Emission</strong> <strong>Monitoring</strong>Multi-component analyzerMulti-component analyzerExtractive measurementGas analysis<strong>Process</strong> control in“problem” gases or liquids.The MCS 100 is equippedwith a very robust singlebeamprocess photometer <strong>for</strong>conducting process measurementsin the UV, VIS, (N)IRspectral range. Up to 8 componentscan be measuredcontinuously. It is also possibleto offset disturbance variables.Cells ranging from the 0.1 mmhigh-pressure liquid cell to thecompact 20 m high-temperaturelong-path cell are available.Applications <strong>Process</strong> control Problematic components High pressure, hightemperature Suitable <strong>for</strong> use in explosiveatmospheres (option)Advantages Cost-effective, robust solution<strong>for</strong> process monitoring Automatic correction ofdisturbance variables Automatic changeover ofmeasuring range with limitmonitoring Automatic sensitivitymonitoring Low maintenance require-<strong>Process</strong> <strong>and</strong> emissionmonitoringThe MCS 100 E compactmulti-component analyzer isused in, <strong>for</strong> example, powerstations or incineration plants.The MCS 100 E contains aninfrared photometer <strong>for</strong> detectingup to a maximum of 8gas components <strong>and</strong> O 2.The following variants arealso available: MCS 100 E-HW withhot-measuring technology MCS 100 E-PD withpermeation dryer MCS 100 E-CD withgas condenserApplications Incineration plants Furnaces Cement industry Crematoriums Special ApplicationsAdvantages Complete flue gas analysissystems from one company Cross-sensitivity compensation Automatic changeover ofmeasuring range with limitmonitoring Automatic sensitivitymonitoring with <strong>and</strong>without calibration gas Low maintenance requirementsTechnical dataMCS 100Technical dataMCS 100 EMeasuring principleSingle-beam infrared photometerbifrequency <strong>and</strong> filter correlationMeasuring principleNo. measured componentsInfrared photometermax. 8 + 0 2No. measured componentsmax. 8Response timeT 90Typ. < 140 secResponse time T 90Signal outputsInterfaces< 2 sec0/4–20 mA, changeover contactRS 232 (24 V)Interfaces2 optical: PC, modem, printer2 opicaal: optical/electronicaltransfer boxEmitterEmitterLensCellChopperLensCellChopperDetectorDetector


The All-In-One Solution from One Source: MKAS 700 St<strong>and</strong>ard System with Gas CoolerMulti-component analysis systemMKAS 700Built-in analyzersS 700 seriesMeasuring value output 0/4 ... 20 mA per meas. component/RS 232<strong>Control</strong>/status signals connected by controller unitInterface RS 232Enclosure rating IP 55Dimensions800 x 2100 x 600 (800) mm<strong>Process</strong> Applications,emis sion measurements orsafety monitoring – abroad range of applications.The MKAS Multi-ComponentAnalysis System from Sis an all-in-one solution <strong>for</strong>moni toring a wide variety ofprocesses.Applications Power stations Cement industry Iron/steel industry Chemical industry Special ApplicationsAdvantages St<strong>and</strong>ard system <strong>for</strong> allprocess-based applications High flexibility <strong>and</strong> userfriendlyretrofitting thanksto modular system concept Easy (low-cost) installation<strong>and</strong> startup of st<strong>and</strong>ardsystem (analysis cabinet)System designAll of the system componentsare housed in an analysiscabinet.The MKAS comprises: Power supply, closed-loopcontrol <strong>and</strong> safeguardingsystem <strong>for</strong> the samplingsystem Measuring gas delivery <strong>and</strong>preparation system Analyzer Calibration unit Open-loop control unit Registration system(optional) Data acquisition <strong>and</strong> processingsystem (optional)Extractive measurement<strong>Systems</strong>Example of an MKAS analysis system<strong>Control</strong>lerSampling probeCondensateCondensateS 700 analyzerTest gasCondensatemonitorZero gasCondensate tank10 l (option)


The multi-component system <strong>for</strong> monitoring flue gases:MCS 100 E HW, MCS 100 E PD, MCS 100 E CDMulti-component analysis systemExtractive measurement<strong>Systems</strong>MCS 100 E HW/MCS 100 E PD/MCS 100 E CDBuilt-in analyzerMCS 100 EMeasuring value output 0 ... 22 mA per measured component<strong>Control</strong>/status signals connected by controller unitInterfaceRS 232 (option)Enclosure rating IP 54Dimensions800 x 2100 x 600 mm<strong>Emission</strong>s monitoring <strong>and</strong>process control <strong>for</strong> flue gasesThe multi-component analysissystem from S fulfils therequirements <strong>for</strong> reliable <strong>and</strong>effective plant operation.Applications Power stations Refuse incineration plants Steel production Cement industry Industrial processesAdvantages Up to 8 gas components,plus O 2 Automatic zero <strong>and</strong> test gasfunction (option) Flexible <strong>and</strong> reliable systems Extremely low maintenancerequirements Several measuring pointsVersionsS offers different versions<strong>for</strong> flue-gas monitoring thatare tailored to different requirements,but based on acommon plat<strong>for</strong>m.• MCS 100 E HW HW withhigh-temperature measuringtechnology <strong>for</strong> refuse incinerationplants• MCS 100 E PD with gas dryer(permeation dryer) <strong>for</strong> recordingextremely smallmeasuring ranges• MCS 100 E CD with gascooler <strong>for</strong> power stations.System DesignAll of the system componentsare housed in a cabinet: Measurement gas transportation<strong>and</strong> preparation components(gas cooler, permeationdryer, pump) MCS 100 E analyzer <strong>Control</strong> unit Additional analysis devicesExample <strong>for</strong> the MCS 100 E HW systemzero gas<strong>Control</strong>MCS 100 EBack-flushingAnalyzerMeasuringgas outletMCS sampling probeSupply linesMessgasleitungMeasuring gas pumpTest gas


MERCEM <strong>for</strong> emission monitoringMercury analyzer systemMERCEMMeasuring principle Photometer, cold-vapor atomic absorptionMeasured components Hg <strong>and</strong> Hg compoundsResponse time T 90approx. 180 sec<strong>Monitoring</strong> mercury <strong>and</strong>mercury compounds influe gas.The sensitivity of the systemcan be adjusted by adaptingan amalgamation process toenable detection in wide measuringranges <strong>and</strong>, in particular,very narrow measuringranges.Applications Incineration plants Cement industry CrematoriumsAdvantages Detection of elemental mercury<strong>and</strong> mercury in chloridecompounds Very low detection limits Stability with respect tocross sensitivity Automatic sensitivity monitoring(optional) Low maintenance requirementsExtractive measurement<strong>Systems</strong>Signal outputs0/4–20 mA, changeover contactInterface RS 232 (24 V)Enclosure rating IP 54Dimensions800 x 2100 x 600 mmReactorCoolerAnalyzerGassamplingGold trapReactionsolutionBypassPump


Wide selection of probesSMGL – measuring gas linesGas sampling probesHeated measuring gas linesExtractive measurementAccessoriesVersatility thanks to wideselection of samplingpipes.The probes from S aresuitable <strong>for</strong> gas temperaturesup to 1300 °C <strong>and</strong> dust concentrations up to 10 g/m 3 ,even at high humidity levels<strong>and</strong> with process-dependentunder ranging of dew points.Advantages: Compact design Flexibility thanks to modulardesign Simple maintenanceSpecial ProbesS also offers specialprobes <strong>for</strong> special Applications,<strong>for</strong> example: The heated probes (HCB)with sample gas feed <strong>and</strong>automatic back-flushing The HS probe with variableseparator heating The FLK gas samplingsystem <strong>for</strong> temperaturesup to 1400 °C <strong>and</strong> dustconcentrations up to2000 g/m 3 Sampling probe <strong>for</strong> MCSsystems with back-flushingHeated gas lines <strong>for</strong>transporting samplegas without corruptingmeasuring results.Since condensation causedby underranging of the dewpoint can corrupt the measuringresult, the SMGL 1 <strong>and</strong>SMGL 3 sample gas lines providethe ideal solution:variable heating up to 180 °C.The SMGL 2 self-regulatingnon-freezing line is available<strong>for</strong> simple Applications.Advantages: Inner pipe made of chemcallyinert PTFE Temperature monitored byPT 100 sensor Water-tight polyamide corrugatedhose Flame-retardant insulation<strong>and</strong> covering High-grade steel connectingsleeves at probe endTechnical dataProbes (example)Technical dataSMGL 1/SMGL 3Filter elementCeramic 2 µm orglass fiber 0.1 µmInner hosePTFE, ND 4 or 6 mm,high-grade steel braidingSampling pressureAmbient temperature0.4 ... 6 bar (absolute)–20 ... +80 °CInsulationThermo-fleece, FCKW-free,flame-retardantFlangeGas outletDN65/PN61/4” NPTOuter coveringRobust polyamide corrugatedhose, water-tight, flame-retardantPower supply115/230 V; 50/60 Hz, 630 WFittingsHigh-grad. steel sleeves/PTFE hoseTemperature (heaed probe)0 ... 180 °C (optional 320 °C),variableTemperature sensorsHeating2 x PT 100 in two-wire technology0 ... 180 °C, variableWeight15.4 kgPower supply115/230 V; 50/60 Hz; 100 W/m


The Sample Gas CoolerSMAK 6 <strong>and</strong> SMAK 8Additional accessories <strong>for</strong> the extractive gas analysisMeasuring gas coolerAccessoriesHigh dew-point constancy<strong>and</strong> fast dehydration ofsample gas.The dehydration process isper<strong>for</strong>med continuously <strong>and</strong>condensation separation isimmediate.Spiral-pipe heat exchangers Maximum heat transfer rate Reduced washing-out ofsoluble components thanksto fast condensation separation Absorption of peak loadsby non-freezing condenserreservoirsAdvantages High constant dehydrationrate Corrosion-resistant gaschannels High condenser efficiency,even at high ambienttemperatures Very low maintenancerequirementsCompletion of extractiveanalysis systems <strong>for</strong> eachmeasuring task.Overview Gas filter:Available in various versions(filter material, humiditysensors, special versions) Gas <strong>and</strong> condensatepumps:solid design, reliable operation,long service life, <strong>and</strong>maintenance-freeAdditional Accessories Cocks, fittings <strong>and</strong> valves:each in different versiondue to the applications Zero <strong>and</strong> test gas cylinder:<strong>for</strong> monitoring, calibration<strong>and</strong> linearity checks of theanalyzers Pressure reducer:to reduce the pressure ofthe gas cylinder Converter Humidity sensors <strong>and</strong> instrumentationExtractive measurementAccessoriesTechnical dataSMAK 6/SMAK 8Max. gas outlet temperature140 ... 180 °CSample gas outlet temperature2 ... 12 °CAmbient temperature5 ... 45 °CNumber of channels1, 2 or 3Material dof gas channelsPVDF, glass or high-grade steelMax. gas flow250 l/h (SMAK 6) or 75 l/h (SMAK 8)Power supply115/230 V; 50/60 HzPower consumption180 ... 370 W depend. on version


Interested? Copy, Fill In, <strong>and</strong> Fax BackFax +49 7641 469 1149F a x R e p l yCompanyNamePosition/DepartmentAddressPost code/TownPhone/FaxIndustry/Fieldof applicationYes, I would like to knowmore about:<strong>Process</strong> gas analysisI am intersted in a detailed consultationwith one of your project consultants.Please arrange an appointment <strong>for</strong> me.Flue gas analysis technology<strong>Emission</strong> monitoringDust measurement technologyVolume flow measurementData acquisition <strong>and</strong>evaluation systemsWater analysisLiquid analysisLevel measurement technologySICK <strong>and</strong> MAIHAK – the new leading developer of analysis<strong>and</strong> process measuring technology. SICK also providesinnovative factory automation solutions. As a leading providerof sensor systems <strong>for</strong> automation technology, safetysystems, process analysis, <strong>and</strong> auto ident systems,SICK has become a global partner in all areas of industry.A network of subsidiaries, sales <strong>and</strong> service centersensures close contact with customers all over the world.Tunnel sensorsSpecial measuring technologyw w w . s i c k . d eSICK Analysis <strong>and</strong><strong>Process</strong> Measurementwith the following locations:SICK AGNimburger Str. 1179276 ReuteGermanyTel. +49 76 41/469-0Fax +49 76 41/469-11 49SICK Engineering GmbHBergener Ring 4301458 Ottendorf-OkrillaGermanyTel. +49 3 52 05/5 24-10Fax +49 3 52 05/5 24-50SICK UPA GmbHDr.-Zimmermann-Str. 1888709 MeersburgGermanyTel. +49 75 32/8 01-0Fax +49 75 32/8 01-104Maihak AGPoppenbütteler Bogen 9B22399 HamburgGermanyTel. +49 40/2 78 94- 0Fax +49 40/2 78 94-2428 008 966/08-2001 . GB3/SM . Printed in Germany . Subject to change without prior noticeSICK AG • Analysis <strong>and</strong> <strong>Process</strong> Measurement • Nimburger Str. 11 • 79276 Reute, Germany • Tel. +49 76 41 4 69-0 • Fax +49 76 41 4 69-11 49www.sick.de